Loading...
HomeMy WebLinkAboutPermit PL12-007 - AT&T - WIRELESS TELCOMMUNICATIONS FACILITIES TYPE 1AT&T WAl 58 ROXBURY APN: 0423049130 PL1 2-007 Ll 2-007 WIRELESS TELECOMMUNICATIONS TYPE 1 City of Tukwila Jim Haggerton, Mayor Department of Community Development Jack Pace, Director May 10, 2012 NOTICE OF DECISION TO: George Pierce, Applicant gpierce@rykaconsulting.com RYKA Consulting 918 South Horton Street, Suite Seattle City Light 1002 Property Management Seattle WA 987134 1015 3rd Avenue Seattle, WA 98104 This letter serves as a notice of decision and is issued pursuant to TMC 18.104.170 on the following project and permit approval. I. PROJECT INFORMATION Project File Number: L12-007, PL12-007 Applicant: George Pierce, RYKA Consulting for AT&T Type of Permit Applied for: Type 1 Wireless Telecommunications Facilities Permit Project Description: Approval of a Type I Wireless Telecommunication Facilities Permit in order to add 3 new LTE antennas on an existing transmission tower, add a DCX converter inside an existing TE43 cabinet, add a 992 BBU within an LTE 9412 backpack enclosure, and add a raycap surge suppressor enclosure and excess cable enclosure mounted to a new H-frame located within an existing fenced compound. Also, add (6) radio heads mounted on a new H-frame located on an existing concrete slab and add a new LTE GPS antenna to an existing ice bridge post. Location: Parcel NO: 0423049130; vacant parcel used for utility transmission towers. This tower is located just south of 10700 West Marginal Way South. Associated Files: N/A Comprehensive Plan Manufacturing/Industrial Center -Heavy (MIC/H) Designation/Zoning District: sM I Pagel of 4 HAComplete projects\L12-007 Type 1 Wireless AT&M12-007 NOD.doc 05/10/2012 6300 Southcenter Boulevard, Suite 4100 • Tukwila, Washington 98188 • Phone 206-431-3670 • Fax: 206-431-3665 H. DECISION SEPA Determination: The City SEPA Responsible Official has previously determined that this application does not require a SEPA threshold determination because it is categorically exempt. Decision on Substantive Permit: The City Community Development Director has determined that the application for a Type 1 Wireless Telecommunications Facility does comply with applicable City and state code requirements and has approved that application without conditions. III. YOUR APPEAL RIGHTS The Decision on this Permit Application is a Type 1 decision pursuant to Tukwila Municipal Code § 18.104.010. Other land use applications related to this project may still be pending. No administrative appeal of a DNS or an EIS is permitted. One administrative appeal to the City Hearing Examiner of the Decision on the Permit itself is permitted. If an MDNS was issued, any person wishing to challenge either the conditions which were imposed by the MDNS decision or the failure of the Department to impose additional conditions in the MDNS must raise such issues as part of the appeal to the Hearing Examiner. A party who is not satisfied with the outcome of the Hearing Examiner appeal process may file an appeal in King County Superior Court from the Hearing Examiner's decision. IV. PROCEDURES AND TIME FOR APPEALING In order to appeal the Community Development Director decision on the Permit Application, a written notice of appeal must be filed with the Department of Community Development within 14 days of the issuance of this Decision, that is by May 24, 2012. The requirements for such appeals are set forth in Tukwila Municipal Code ch. 18.116. All appeal materials shall be submitted to the Department of Community Development. Appeal materials MUST include: 1. The name of the appealing party. 2. The address and phone number of the appealing party; and if the appealing party is a corporation, association or other group, the address and phone number of a contact person authorized to receive notices on the appealing parry's behalf. 3. A statement identifying the decision being appealed and the alleged errors in the decision, including any specific challenge to an MDNS. 4. The Notice of Appeal shall identify (a) the specific errors of fact or errors in application of the law in the decision being appealed; (b) the harm suffered or anticipated by the appellant, and (c) the relief sought. The scope of an appeal shall be limited to matters or issues raised in the Notice of Appeal. 5. Appeal fee of $541 plus retainer. SM Page 2 of 4 05/10/2012 HAComplete projects\1,12-007 Type 1 Wireless AT&T\L12-007 NOD.doc V. APPEAL HEARINGS PROCESS Any administrative appeal regarding the Permit shall be conducted as a closed record hearing before the Hearing Examiner based on the information presented to the Community Development Director, who made the original decision. No new evidence or testimony will be permitted during the appeal hearing. Parties will be allowed to present oral argument based on the information presented to the Community Development Director before their decision was issued. The Hearing Examiner's decision on the appeal is the City's final decision. Any party wishing to challenge the Hearing Examiner's decision on this application must file an appeal pursuant to the procedures and time limitations set forth in RCW ch. 36.70C. An appeal challenging a DNS, an MDNS or an EIS may be included in such an appeal. If no appeal of the Hearing Examiner's decision is properly filed in Superior Court within such time limit, the Decision on this permit will be final. The City's decision to issue a DNS, an MDNS or an EIS is final for this permit and any other pending permit applications for the development of the subject property. VI. INSPECTION OF INFORMATION ON THE APPLICATION Project materials including the application, any staff reports, and other studies related to the permits are available for inspection at the Tukwila Department of Community Development, 6300 Southcenter Blvd., Suite 100,-Tukwila, Washington 98188 from Monday through Friday between 8:30 a.m. and 5:00 p.m. The project planner is Stacy MacGregor, who may be contacted at 206-433-7166 or via email at smacgregor@ci.tukwila.wa.us for further information. Property owners affected by this decision may request a change in valuation for their property tax purposes. Contact the King County Assessor's Office for further information regarding property tax valuation changes. Department of Community Development City of Tukwila sM Page 3 of 4 05/10/2012 HAComplete projects\L12-007 Type I Wireless AT&T\L12-007 NOD.doc 4 City of Tukwila Department of Community Development STAFF REPORT TO THE DIRECTOR PREPARED May 10, 2012 Jim Haggerton, Mayor Jack Pace, Director NOTIFICATION: Notification is not required for a Type I land use application. FILE NUMBER: L12-007, PL12-007 APPLICANT: George Pierce, RYKA Consulting for AT&T PROPERTY OWNER: Seattle City Light REQUEST: Approval of a Type I Wireless Telecommunication Facilities Permit in order to add 3 new LTE antennas on an existing transmission tower, add a DCX converter inside an existing TE43 cabinet, add a 992 BBU within an LTE 9412 backpack enclosure, and add a raycap surge suppressor enclosure and excess cable enclosure mounted to a new H- frame located within an existing fenced compound. Also, add (6) radio heads mounted on a new H-frame located on an existing concrete slab and add a new LTE GPS antenna to an existing ice bridge post. LOCATION: Parcel NO: 0423049130; vacant parcel used for utility transmission towers. This tower is located just south of 10700 West Marginal Way South. ASSOCIATED PERMITS: N/A SEPA DETERMINATION: Exempt COMPREHENSIVE PLAN DESIGNATION: Manufacturing/Industrial Center -Heavy (MIC/H) ZONE DESIGNATION: Manufacturing/Industrial Center -Heavy (MIC/H) STAFF: Stacy MacGregor, Assistant Planner ATTACHMENTS: Project Plans for Permit L12-007 sM Page 1 of 4 HAComplete projectAL12-007 Type 1 Wireless AT&T\L12-007 SR.doc 05/10/2012 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone 206-431-3670 • Fax: 206-431-3665 16 FINDINGS Vicinity/Site Information Project Description The applicant is requesting approval of a Type I Wireless Telecommunication Facilities [WCF] Permit to add equipment to an existing tower at a location south of 10700 West Marginal Way South. The project includes adding 3 new LTE antennas on an existing transmission tower, adding a DCX converter inside an existing TE43 cabinet, adding a 992 BBU within an LTE 9412 backpack enclosure, and adding a raycap surge suppressor enclosure and excess cable enclosure mounted to a new H-frame located within an existing fenced compound. Also, adding (6) radio heads mounted on a new H-frame located on an existing concrete slab and adding a new LTE GPS antenna to an existing ice bridge post. The existing electrical utility tower is 157 feet high with the AT&T antennas to be mounted at 85 feet adjacent to existing AT&T antennas; additionally antenna currently mounted at 135 feet high will be removed by Seattle City Light in the future. ExistingDevelopment This site is part of the Seattle City Light utility route. In addition to the tower, the site contains the Association's building and a few outbuildings. Surrounding Land Uses The property and the surrounding parcels are zoned MIC/H. BACKGROUND In 2006, the City adopted a Wireless Facilities Chapter (TMC 18.71) to the Zoning Code. The chapter provides specific location and design requirements for the placement of WCF within the City of Tukwila. The WCF being.modified was originally approved by the City in 2000 (L98-0018) through a conditional use permit. Location Selection Tukwila Municipal Code (TMC) provides a hierarchy of appropriate locations within the City. Generally, co -locations and utilizing existing structures are favored over the development of new standalone WCF within the City. TABLE A Type of Permit Required, Based on Type of Wireless Communication Facility ZONING (1) TYPE OF FACILITY RESIDENTIAL COMMERCIAL INDUSTRIAL Transmission Tower co -location Type 1 Type 1 Type 1 Adding antennas to an existing tower Type 1(2) Type 1(2) Type 1(2) Utility pole co -location Type 2 Type 2 Type 2 Concealed building attached Type 2(3) Type 2(3) Type 2(3) Non -concealed building attached Type 2 Type 2 Type 1 New tower or waiver request Type 4 Type 4 Type 4 SM Page 2 of 05/10/2012 HAComplete projects\L.12-007 Type 1 Wireless AT&TU.12-007 SR.doc (1) Zoning for any private/public property or right-of-way Residential — LDR, MDR, or HDR Commercial — O, MUO, RCC, NCC, RC, RCM, TUC, C1LI or TVS Industrial - LI, HI, MIC/L, or MIC/H (2) Provided the height of the tower does not increase and the square footage of the enclosure area does not increase. (3) An applicant may request to install a non -concealed building attached facility, under TMC Section 18.58.150. The applicant is adding additional antennas to an existing tower. This decision does not require the use of any new facilities for placement of the new antennas. Design Standards The City provides specific design standards for the placement of WCF within the City of Tukwila. The table below indicates if the applicant's proposal complies with required standards. Table B Design Standards Project Project Not Applicable does comply does not com I 1. Generators must comply with TMC The applicant has not 8.22 regarding noise. proposed a new generator. 2.13usiness License Requirement AT&T has applied for a business license (007708). 3. Only safety signage must be placed The applicant does on the WCF. not propose any signage. 4. Accommodations for parking for Parking is not maintenance personal must be affected by this provided. modification. 5. Towers shall either maintain a No change to the galvanized steel finish or be painted a existing tower is neutral color so as to reduce its visual proposed. obtrusiveness. 6. The design of all buildings and No new buildings or ancillary structures shall use materials, structures are colors, textures, screening, and proposed. landscaping that will blend the tower facilities to the natural setting and built environment. 7. Antennas shall have the same color These antennas will be scheme as the structure they are located on a utility located on. tower, therefore this criteria does not apply. 8. WCF poles and towers shall only No lighting is have safety lights if required by a proposed. government agency. sm Page 3 of 4 05/10/2012 HAComplete projects\L12-007 Type 1 Wireless AT&T\L12-007 SR.doc 9. No advertising is permitted on No advertising is WCF proposed. 10. Each service provider shall be No change to the limited to an equipment enclosure of existing equipment 360 square feet. enclosure is proposed. 11. When adding antennas to existing These antennas will be WCF towers, height must not exceed located on a utility what was approved under the original tower, therefore this application to construct the tower. criteria does not apply. 12. Antennas shall be painted to match Antennas and ancillary the color scheme of tower. equipment will be painted to match the existing tower color. 20. Feed lines and coaxial cables shall Coaxial cables will be be located within the tower. Those attached to the east leg of the exposed shall be painted to match tower. All feed lines will be tower. painted to match the transmission tower. 21. A new cabinet shall be located The existing and proposed within the equipment enclosure that equipment cabinets will be was approved as part of the original located within the existing, application. slatted, fenced equipment enclosure approved as file number L97-0073. CONCLUSIONS 1. The proposed modifications to the existing antenna will not significantly alter the conditions that currently exist. The height of the tower will not change. 2. As demonstrated in Table B, the project meets all applicable development standards. 3. The proposed modifications will not alter the surrounding land uses in terms of traffic and pedestrian circulation, building or site design. 4. The proposed project is in keeping with the goals and policies of the Comprehensive Land Use Policy Plan. RECOMMENDATIONS The recommendation to the Director of Community Development is to approve this application for a Type I Wireless Telecommunication Facility permit as applied for by RYKA Consulting for AT&T without conditions. SM Page 4 of 4 05/10/2012 HAComplete projects\L12-007 Type 1 Wireless AT&T\L12-007 SR.doc CITY OF TUKWILA Department of Community Development 6300 Southcenter Boulevard, Tukwila, WA 98188 Telephone: (206) 431-3670 FAX (206) 431-3665 E-mail: tukplanAciAukwila.wa.us AFFIDAVIT OF OWNERSHIP AND HOLD HARMLESS STATE OF WASHINGTON ss COUNTY OF KING PERMISSION TO ENTER PROPERTY The undersigned being duly sworn and upon oath states as follows: 1. I am the current owner of the property which is the subject of this application. 2. All statements contained in the applications have been prepared by me or my agents and are true and correct to the best of my knowledge. 3. The application is being submitted with my knowledge and consent. 4. Owner grants the City, its employees, agents, engineers, contractors or other representatives the right to enter upon Owner's real property, located at 10 6 0 0 Marginal Way S for the purpose of application review, for the limited time necessary to complete that purpose. 5. Owner agrees to hold the City harmless for any loss or damage to persons or property occurring on the private property during the City's entry upon the property, unless the loss or damage is the result of the sole negligence of the City. 6. Non -responsiveness to a City information request for ninety (90) or more days, shall be cause to cancel the application(s) without refund of fees. EXECUTEDat Seattle (city), WA (state), on August 9 Doug Haberman (Print Name) 3613 4th Ave S, Seattle, WA (Address) 2 0 6- 7 3 3- 913 8 (Phone Number) Z0 11 (Signature) / / v On this day personally appeared before me N (/ to me known to be the individual who executed the foregoing instrument and acknowle ged th#J he/she signed the same as his/her voluntary act and deed for the uses and purposes mentioned therein. SUBSCRIBED AND SWORN TO BEFORE ME ON Notary Public State of Washington RACHEL N. TITUS MY COMMISSION EXPIRES September 18, 2013 L DAY OF , 2011- t . in and for the State of Washingt n residing at My Commission expires on C:\DOCUME—I\SCOTT--I.TUK\LOCALS-1\Temp\XPGrpWise\Wireless Communication Facility-Jan2011.doc 1908 Department of Community Development WIRELESS TELE- 6300 Southcenter Boulevard, Tukwila, WA 98188 COMMUNICATION Telephone: (206) 431-3670 FAX (206) 43 CEIVEDFACILITIES E-mail: tukplan@ci.tukwila.wa.us MAR 3 0 2012i CITY OF TUKWILA NAME OF PROJECT/DEVELOPMENT: AT&T Uklib R oX LOCATION OF PROJECT/DEVELOPMENT: Give street address or, if vacant, indicate lot(s), block and subdivision, access street, and nearest intersection. PR�Ei � o�t�3o�tg�:�o LIST ALL TAX LOT NUMBERS (this information may be found on your tax statement). DEVELOPMENT COORDINATOR: The individual who: • has decision making authority on behalf of the owner/applicant in meetings with City staff, • has full responsibility for identifying and satisfying all relevant and sometimes overlapping development standards, and • is the primary contact with the City, to whom all notices and reports will be sent. Name: 6C6'0P4Q P AU1; Address: Al $ San &rt#u S f• 5Ta tcria+ St*1to wk 90/3 Y Phone: 06 . S'13. 19 4 1 FAX: g06. ,' 6. 713 0 E-mail: t1. r�ca (J ry kA gOmWIH d 1. cc.h Signature: . A/a012 C:\DOCUM&1\SCOTT---l.TUK\LOCALS-1\Temp\XPGrpWise\Wireless Communication Facility-Jan2011.doc The materials listed below must be submitted with your application unless specifically waived in writing the Department of Community Development. Please contact each Department if you feel that certain items are not applicable to your project and should be waived. Application review will not begin until it is determined to be complete. ADDITIONAL MATERIALS MAY BE REQUIRED. The initial application materials allow project review to begin and vest the applicant's rights. However, the City may require additional information as needed to establish consistency with development standards. City staff are available to answer questions about application materials at 206-431-3670 (Department of Community Development) and 206-433-0179 (Department of Public Works). Check items Information Required. submitted with May be waived in unusual cases, upon approval of both Public Works and Planning application APPLICATION MATERIALS: Items 1-9 are required for ALL Wireless Telecommunication Facilities. 1. Application Checklist (1 copy) indicating items submitted with application. 2. Completed Application Form 3. Four sets of plans prepared by a design professional. The plans shall include a vicinity map, site map, architectural elevations, method of attachment, proposed screening, location of proposed antennas, and all other information which accurately depicts the proposed project. Minimum size is 8.5" by 11". Plans shall be no greater than 24" x 36". 4. Application Fee: See Land Use Fee Schedule. 5. Completed and notarized Affidavit of Ownership and Hold Harmless Permission to Enter Property (1 copy attached). 6. SEPA Environmental Checklist. SEPA is not required when the facility: i) Is a microcell and is to be attached to an exiting structure that is not a residence or school and does not contain a residence or a school; Includes personal wireless antennas, other than a microcell, and is to be attached to an existing structure (that may be an existing tower) that is not a residence or school and does not contain a residence or school, and the existing structure to which it is to be attached is located in a commercial, industrial, manufacturing, forest or agriculture zone; or iii) Involves constructing a personal wireless tower less than sixty feet in height that is located in a commercial, industrial, manufacturin forest, or agricultural zone. 7. A letter from the applicant describing the proposed project and describing compliance with the Ci 's Code requirements. 1 k 8. Sensitive Area studies and proposed mitigation (if required). ` 9. If an outdoor generator is proposed, a report prepared by an acoustical engineer demonstrating compliance with TMC Chapter 8.22, "Noise". C:\DOCUME-1 \SCOTT--I.TUK\LOCALS-1 \Temp\xPGrpW ise\Wireless Communication Facility-Jan2011.doc If the application requires a Type 2 review these additional items are needed: 110. Four sets of photo simulations that depict the existing and proposed view of the proposed N farility� 11. Materials board for the screening material; 12. Landscavina elan: 13. Letter from a radio frequency engineer that demonstrates that the facility meets Federal requirements for allowed emissions; 14. If the facility is located within a residential zone, a report from a radio frequency engineer explaining the need for the proposed wireless communication facility at that location. Additionally, the applicant shall provide detailed discussion on why the wireless communication facility cannot be located within a commercial or industrial zone. If the application requires a Type 3 review these additional items are needed: U 1A 1 15. A narrative responding to the criteria at TMC Section 18.58.060. 1 16. The radio frequency engineer report shall include a discussion of the information required I under TMC Section 18.58.070. The report shall also explain why a tower must be used instead of any of the other location options outlined in Table A. 17. Engineering Plans for the proposed tower. 18. A vicinity map depicting the proposed extent of the service area. 19. A graphic simulation showing the appearance of the proposed tower and ancillary structures and ancillary facilities from five points within the impacted vicinity. Such points are to be mutually agreed upon by the Director of DCD and applicant. All plans and photo simulations shall include the maximum build -out of the proposed facility. 20. Evidence of compliance with Federal Aviation Administration (FAA) standards for height and lighting and certificates of compliance from all affected agencies. 21. Evidence that the tower has been designed to meet the minimum structural standards for wireless communication facilities for a minimum of three providers of voice, video or data transmission services, including the applicant, and including a description of the number and types of antennas the tower can accommodate. PUBLIC NOTICE MATERIALS: 22. Payment of a $365 notice board fee to FastSigns Tukwila or �,A, Provide a 4' x 4' public notice board on site within 14 days of the Department determining that a complete application has been received (see Public Notice Sien Svecifications Handout)_ 23. Pay the fee as established by the Land Use Fee Schedule for generating mailing labels; Or provide an excel spreadsheet of mailing labels for all property owners and tenants (residents and businesses) within 500 feet of the subject property. Each unit in multiple family buildings e.g. apartments, condos, trailer parks —must be included. Once your project is assigned to a planner, you will be required to provide an electronic copy of the mailing label spreadsheet in the following format: Name, Street Address, City St Zip, with each of these fields as an individual column: Name Street Address City, St, Zip Mr. Smith 1234 Park Ave S Tukwila WA 98188 PLEASE NOTE: Regardless of whether you pay the City to generate the mailing labels or you provide them, there is an additional fee for postage and material as listed under Public Notice Mailing Fee on the Land Use Fee Schedule. Payment of this fee is due prior to issuance of the decision and you will receive a separate bill for this fee. 24. If providing own labels, include King County Assessor's map(s) which shows the location of each property within 500 ft. of the subject lot. CADOCUME-1 \SCOTT--I.TUK\L0CA15-1 \Temp\XPGrpWise\Wireless Communication Facility-Jan2011.doc Ryka Consulting 11 Written Narrative for WA158 Applicant Responses to General Requirements for All Wireless Communication Facilities. 1. Noise — Any facility that requires a generator or other device which will create noise must demonstrate compliance with TMC Chapter 8.22, "Noise ". A noise report, prepared by an acoustical engineer, shall be submitted with any application to construct and operate a wireless communication facility that will have a generator or similar device. The City may require that the report be reviewed by a third party expert at the expense of the applicant. Applicant Response: A generator or other noise producing device is not required as part of this application. 2. Business license requirement — Any person, corporation or entity that operates a wireless communication facility within the City shall have a valid business license issued annually by the City. Any person, corporation or other business entity which owns a tower also is required to obtain a business license on an annual basis. Applicant Response: Applicant understands and will comply. 3. Signage — Only safety signs or those mandated by other government entities may be located on wireless communication facilities. No other types of signs are permitted on wireless communication facilities. Applicant Response: This application is for the modification of an existing wireless facility, and therefore no additional signage is proposed. All existing signage meets the above development standards. 4. Parking — Any application must demonstrate that there is sufficient space for temporary parking for regular maintenance of the proposed facility. Applicant Response: This application is for the modification of an existing wireless facility, and therefore no additional parking is required. Existing parking is available. S. Finish — A tower shall either maintain a galvanized steel finish or, subject to any applicable standards of the FAA or FCC, be painted a neutral color so as to reduce its visual obtrusiveness, Applicant Response: This application is for the modification of an existing wireless facility, and therefore this proposal is not for the installation of a new tower. The existing tower has a galvanized steel finish, and does not require FAA mandated painting. 6. Design — The design of all buildings and ancillary structures shall use materials, colors, textures, screening and landscaping that will blend the tower facilities with the natural setting and built environment. Applicant Response: This application is for the modification of an existing wireless facility, and therefore no additional buildings or ancillary structures are proposed. The existing ground equipment is enclosed within a fence, which utilizes sight -obscuring slats. 7. Color — All antennas and ancillary facilities located on buildings or structures other than towers shall be of a neutral color that is identical to or closely compatible with the color of the supporting structure so as to make the antenna and ancillary facilities as visually unobtrusive as possible. Ryka Consulting 12 Written Narrative for WA158 Applicant Response: This application is for the modification of an existing wireless facility located on a tower, and therefore this standard does not apply. 8. Lighting — Towers shall not be artificially lighted unless required by the FAA, FCC or other applicable authority. Zf lighting is required, the reviewing authority shall review the lighting alternatives and approve the design that would cause the least disturbance to the surrounding areas. No strobe lighting of any type is permitted on any tower. Applicant Response: This application is for the modification of an existing wireless facility. Existing tower does not have artificial lighting, and new lighting is not proposed. 9. Advertising — No advertising is permitted at wireless communication facility sites or on any ancillary structure or facilities equipment compound. Applicant Response: Applicant is not proposing to install advertising. Existing site conditions meet this standard. IL Equipment Enclosure — Each applicant shall be limited to an equipment enclosure of 360 square feet at each site. However, this restriction shall not apply to enclosures located within an existing commercial, industrial, residential or institutional building. Applicant Response: The existing equipment concrete pad is 256sq/ft., which meets this standard. The entire equipment compound is located within the footprint of the Seattle City Light SST Utility Tower, and screened with sight obscuring slats. Specific Design Standards Based on Type of Facility 18.58.080 Electrical Transmission Tower Co -Location -Specific Development Standards. The following requirements shall apply: 1. Height — There is no height requirement for antennas that are located on electrical transmission towers. Applicant Response: This application is for the modification of an existing wireless facility, and an increase in facility height is not proposed. 2. Antenna aesthetics — There are no restrictions on the type of antennas located on the electrical transmission tower. The antennas must be painted to match the color of the electrical transmission tower. Applicant Response: All proposed antennas will be painted to match the existing tower. 3. Antenna intensity — There is no limit on the number of antennas that may be located on an electrical transmission tower ,structure. Applicant Response: Applicant understands. 4. Feed lines and coaxial cables — shall be attached to one of the legs of the electrical transmission tower. The feed lines and cables must be painted to match the color of the electrical transmission tower. Ryka Consulting 3 Written Narrative for WA158 Applicant Response: All existing and proposed feed lines (coax) are attached to the East tower leg. All existing and proposed feed lines will be painted to match the transmission tower. 5. Cabinet equipment — Cabinet equipment shall be located directly under the electrical transmission tower where the antennas are located or a concealed location. The wireless communication equipment compound shall be fenced; the fence shall have a minimum height of 6 feet and a maximum height of 8 feet. The fence shall include slats, wood panels, or other materials to screen the equipment from view. Barbed wire may be used in a utility right-qf-way that is not zoned residential. Applicant Response: All existing and proposed equipment cabinets will be located within the footprint of the existing transmission tower. The 6' fence utilizes sight -obscuring slats. The existing fence and equipment pad will. not be altered as part of this proposal. An additional cabinet will be installed on the existing concrete pad. 6. Setbacks — Since the facility will be located on an existing electrical transmission tower, setbacks shall not apply. Applicant Response: Applicant Understands 0423049130 Tf{i ■ -6 5 R 10 '. 1 R$ S 1i9TT11 ST t f� ,1 .. RIA Tukwila Duwamish River papk j .ate: Duwamish S 112TN ST 1c 120D2 Xing county 0 C The information included on this map has been compiled by King County staff from a variety of sources and Is subject to change without notice. King County makes no representations or warranties, express or implied, as to accuracy, completeness, timeliness, or rights to the use of such infertnafon. dM This document Is not intended for use as a survey product. Kin County shall not be liable for any general, special, indirect, Incidental, or consequential damages including, but not limited to, lost revenues or lost profs resulting from the use or misuse of the Information contained on this map. Any sale of King County this map or information on this map is prohibited except by written permission of King County. a Date: 3/30/2012 Source: King County NAP - Property Information (http:/twww.metrokc.gov/GlSfiMAP) ��~_00:7 0423049130 Highlighted (Feature i 1 County (Boundary X Mountain Peaks, (Highways /. Forest IPrrod'uction (district Boundary Aigricuiturail iProduction f District (Boundary Urban Growth Area !Line % incorlporated Area Streets "- / utrglrMv Local E Lakes and (Large 'Divers, /,f Streams El Triba'I Landis Leib Parcels IParkls Unincorporated IKC Zoning L A-10 - Agricultural, one ID'U per 10 ataas QA-35 - Agricutturat one Oil per 35 acra3 F-Forst M m mineral RA=2:5 (Rural Area, one OU per 5 atoms CIRA-S - Rural Area, ana DU per 5 acres RA-10 - Rural Area, auto OU per 10 arm U'R - Urban (Reserve, ane DU per 5 acres R-1-oResidanf4 ana OU you acra R-d - Residential, 4 OU per ago R-B - Residential, B IDU par acre R-I = RasidentiA 8 OU por am R-12 IRosidenii412 OU per acre R-18 - Razid'enli418 OU (par ave IR-24 - Residential, 24 OIJ per acre �coritj DIR-M - RosideriU4 4 0U par sane INS! - Neigltbwhood''ausinass [� CB - Coarm-nity Business Rli - Rogional IBusineas U D 0 - Office 1- Industuial i no mrormauon mau0e0 on in,., map nas been compiled by tang county staff from a variety of sources and Is subject to change without notice. King County makes no representations or warranties, express or implied, as to accuracy, completeness, timeliness, or rights t0 the use of such information. This document Is not intended for use as a survey product. King County shall not be liable for any general, special, indirect, Incidental, or consequential LQ damages including, bill not limited to, lost revenues or lost profits resulting from the use or misuse of the information contained on this map. Any sale of King County this map 0r in ton on this map is prohibited except by written permission of King County. Date: 3/30/2012 Source: King County WAP- Property Information (http:/Avww.metrokc.gov/GISAMAP) 4/2 -oa7 4 at&t Your world. Delivered. VICINITY MAP 5-103rd SL S1y S') N SITE LOCATIbfl aY I DRIVING DIRECTIONS ROXB U RY 10710 WEST MARGINAL WAY S TUKWILA, WA 98168 KING COUNTY WA158 SEATTLE CITY LIGHT TOWER: SCL PM# 230404-4-601, TRANSMISSION TOWER # DU 0/34 GENERAL LOCATION MAP f.l f � tml--��•-..• C0 ,� -�-Hentler50n - L <-,-� L q U .. 0. } � �. '' 4 i. � 8r d • �SITE LOTION I w` aj 1211! St :TT $I176111-,9 I :_-HUCNs� � �j 81�8L1�St �,,. Nkmern, 1 I r--(- , ; i < � I -ems - �I,I. -� �r� r I - a -� .L �l r -�— t STARTING FROM REDMOND OFFICE: TURN RIGHT ONTO 164th AVENUE NE, GO 220 FT. TURN RIGHT ON BEAR CREEK PKWY, GO 0.3 MI. TURN LEFT ON LEARY WAY, GO 0.3 MI. TAKE THE RAMP ONTO WA-520 W, GO 5.0 MI. TAKE THE EXIT ONTO 1-405 S TOWARD RENTON, GO 14.7 MI. TAKE THE EXIT TOWARD 1-5 N, GO 197 FT. KEEP RIGHT AT THE FORK AND FOLLOW SIGNS FOR SEATTLE/1-5 AND MERGE ONTO 1-5 N, GO 1.2 MI. TAKE EXIT #156 FOR WA-599 TOWARD W MARGINAL WAY / TUKWILA, GO 0.5 MI. CONTINUE ON WA-599, GO 2.4 Mi. TAKE THE W MARGINAL PL EXIT, GO 0.1 MI. TURN RIGHT ON 27th AVENUE S, GO 0.2 MI. SITE IS A LATTICE TOWER ON THE LEFT. APPROVAL / SIGN OFF OF DRAWINGS CONSULTANT GROUP SIGN OFF DATE INITIAL AND PRINT NAME AT&T SIGN OFF DATE INITIAL AND PRINT NAME LANDLORD'S REPRESENTATIVE RF ENGINEER CONSTRUCTION COORDINATOR INTERCONNECT PROJECT MANAGER OPERATIONS SITE ACQUISITION COMPLIANCE ZONING CONSTRUCTION MANAGER CONSTRUCTION MANAGER PROJECT MANAGER REVIEWERS SHALL CLEARLY PLACE INITIALS ADJACENT TO EACH REDLINE NOTE AS DRAWINGS ARE BEING REVIEWED PROJECT INFORMATION APPLICANT: PROPERTY & TOWER OWNER: AT&T MOBILITY CORPORATION CITY OF SEATTLE 16221 NE 72nd WAY, RTC 3 SEATTLE CITY LIGHT P.O. BOX 97061 REAL ESTATE SERVICES REDMOND, WA 98052 700 5TH AVE, SUITE 3000 SEATTLE, WA 98104 PROJECT ENGINEER: ATTN. DOUG HABERMAN CORNERSTONE ENGINEERING, INC. PH: (206) 733-9138 16928 WOODINVILLE-REDMOND RD N.E. SUITE 210 PROJECT MANAGER: WOODINVILLE, WA98072 MARK W OLSON, P.E. CHARLES COOK PH: (425) 487-1732 (972) 679-9184 FAX: (425) 487-1734 ccook@goodmannetworks.com CONSTRUCTION MANAGER: PROJECT CONSULTANTS: TAI ISH GOODMAN NETWORKS (972) 259 73 97 8815 122ND AVE. NE girish@goodoodmannelworks.com KIRKLAND, WA98033 SITE ACQUISITION: CODE INFORMATION: GEORGE PIERCE ZONING CLASSIFICATION: MIC/H (206) 406-5117 BUILDING CODE: IBC 2009 gpierce@rykaconsulting.com CONSTRUCTION TYPE: TELECOMMUNICATIONS PERMITTING: OCCUPANCY: UNOCCUPIED GEORGE PIERCE JURISDICTION: CITY OF TUKWILA (pie) 406-5117 9Pierce@rykaconsulting.com PROPOSED BUILDING USE: TELECOMM RF ENGINEER: SITE LOCATION: (BASED ON NAD 83) KUNG-LIANG LIN LATITUDE: 47° 30' 23.5" N (47.5065) (425) 698-7825 LONGITUDE: 122° 17' 58.4- W (122.2995) TOP OF STRUCTURE: 156'-8" AGL PARCEL NUMBER: BASE OF STRUCTURE: 18.251' AMSL (NAVD 88) 0423049130 AREA OF PARCEL: PROJECT AREA: 822,899 SO FT ±380 SQ. FT. COMPOUND (18.89 ACRES) NEW IMPERVIOUS AREA: 0 SQ. FT. GENERAL INFORMATION: 1. PARKING REQUIREMENTS ARE UNCHANGED. (NON ASSIGNED TECH PARKING) 2. TRAFFIC IS UNAFFECTED. 3. NO SIGNAGE IS PROPOSED. PROJECT DESCRIPTION: THIS PROPOSAL IS FOR THE MODIFICATION OF AN EXISTING UNMANNED TELECOMMUNICATIONS FACILITY, CONSISTING OF THE ADDITION OF (3) NEW LTE PANEL ANTENNAS (1 PER SECTOR) ON AN EXISTING TRANSMISSION TOWER; ADD A DC CONVERTER INSIDE AN EXISTING TE43 CABINET, AND ADD A 9926 BBU WITHIN AN LTE 9412 BACKPACK ENCLOSURE, RAYCAP SURGE SUPPRESSOR ENCLOSURE AND EXCESS CABLE ENCLOSURE MOUNTED TO A NEW H-FRAME LOCATED WITHIN AN EXISTING FENCED COMPOUND; ALSO ADD (6) REMOTE RADIO HEADS (RRH) MOUNTED ON A NEW H-FRAME LOCATED ON AN EXISTING CONCRETE SLAB; ALSO ADD A NEW LTE GPS ANTENNA TO AN EXISTING ICE BRIDGE POST. PROPRIETARY INFORMATION THE INFORMATION CONTAINED IN THIS SET OF CONSTRUCTION DOCUMENTS IS PROPRIETARY BY NATURE. ANY USE OR DISCLOSURE OTHER THAN THAT WHICH RELATES TO AT&T WIRELESS, LLC. SERVICES IS STRICTLY PROHIBITED. DRAWING INDEX DWG. NO. DESCRIPTION T-1 TITLE SHEET G-1 GENERAL NOTES A-1 SITE PLAN A-1.1 EXISTING & PROPOSED ENLARGED SITE PLANS A-2 EXISTING & PROPOSED SOUTHEAST ELEVATIONS A-3 DETAIL SHEET A-3.1 DETAIL SHEET RF-1 EXISTING & PROPOSED ANTENNA PLANS E-1 SCHEMATIC GROUNDING PLAN E-2 GROUNDING DETAILS I LEGAL DESCRIPTION I C OF S TRANS LN R/W OVER GL 4 & 5 TGW SE 1/4 LESS ST HWY TGW 250 FT R[W OVER TRACT 55 OF MOORES FIVE -ACRE TRACTS & VAC G FRAIEGER RD LESS ST HWY RECEIVED MAR 3 0 20121 COMMUNi7Y DEVELOPMENT at&t Your world. Delivered. RVJGVI VVIVJVLIMIVIJ. GoodmanNetworks PLANS PREPARED BY: OPINEA61170NE 16928 WOODINVILLE-REDMOND RD NE, SUITE 210 WOODINVILLE, WA 98072 PHONE: 425,487,1732 FAX 425.487.1734 EMAIL: cei@cor erstone�rgccom W W W.CORNERSTONE-ENGR.COM r. PROJECT INFO: L ISSUED FOR: 1 CCONSTRUCTION r.REV: =DATE:=ISSUED FOR: B] Qp 08-31-11 CONSTRUCTION JRS Qq 06-30-11 CLIENT REVIEW AJB 1 DRAWN BY: =CHK.: APV.: LAJB I BMH MWO [CURRENT ISSUE DATE: 08-31-11 LICENSURE: p�K W OAS �F S5 11E?4'�/�I�� ONALE DRAWING INFORMATION: DO NOT SCALE DRAWINGS, CONTRACTOR MUST VERIFY ALL DIMENSIONS AND ADVISE CONSULTANTS OF ANY ERRORS AND OMISSIONS. ALL PREVIOUS ISSUES OF THIS DRAWING ARE SUPERSEDED BY THE LATEST REVISION. THE INFORMATION CONTAINED IN THIS SET OF DOCUMENTS IS PROPRIETARY BY NATURE. ANY USE OR DISCLOSURE OTHER THAN WHICH IS RELATED TO NAMED CLIENT IS STRICTLY PROHIBITED, DRAWING TITLE: TITLE SHEET DRAWING NUMBER: T-1 0 CEI JOB NUMBER: 11-69043 GENERAL NOTES: 1. DRAWINGS ARE NOT TO BE SCALED, WRITTEN DIMENSIONS TAKE PRECEDENCE. THIS SET OF DOCUMENTS IS INTENDED TO BE USED FOR DIAGRAMMATIC PURPOSES ONLY, UNLESS NOTED OTHERWISE. THE GENERAL CONTRACTOR'S SCOPE OF WORK SHALL INCLUDE FURNISHING ALL MATERIALS, EQUIPMENT, LABOR, AND ANY REQUIREMENTS DEEMED NECESSARY TO COMPLETE PROJECT AS DESCRIBED IN THE DRAWINGS AND OWNER'S PROJECT MANUAL. 2. PRIOR TO THE SUBMISSION OF BIDS, CONTRACTORS INVOLVED SHALL VISIT THE JOB SITE TO FAMILIARIZE THEMSELVES WITH ALL CONDITIONS AFFECTING THE PROPOSED PROJECT. CONTRACTORS SHALL VISIT THE CONSTRUCTION SITE WITH THE CONSTRUCTION/CONTRACT DOCUMENTS TO VERIFY FIELD CONDITIONS AND CONFIRM THAT THE PROJECT WILL BE ACCOMPLISHED AS SHOWN. PRIOR TO PROCEEDING WITH CONSTRUCTION, ANY ERRORS, OMISSIONS, OR DISCREPANCIES SHALL BE BROUGHT TO THE ATTENTION OF THE ARCHITECT/ENGINEER VERBALLY AND IN WRITING. 3. THE ARCHITECTS/ENGINEERS HAVE MADE EVERY EFFORT TO SET FORTH IN THE CONSTRUCTION AND CONTRACT DOCUMENTS THE COMPLETE SCOPE OF WORK. CONTRACTORS BIDDING THE JOB ARE NEVERTHELESS CAUTIONED THAT MINOR OMISSIONS OR ERRORS IN THE DRAWINGS AND OR SPECIFICATIONS SHALL NOT EXCUSE SAID CONTRACTOR FROM COMPLETING THE PROJECT AND IMPROVEMENTS IN ACCORDANCE WITH THE INTENT OF THESE DOCUMENTS. THE BIDDER SHALL BEAR THE RESPONSIBILITY OF NOTIFYING (IN WRITING) THE ARCHITECTIENGINEER OF ANY CONFLICTS, ERRORS, OR OMISSIONS PRIOR TO SUBMISSION OF CONTRACTOR'S PROPOSAL. IN THE EVENT OF DISCREPANCIES THE CONTRACTOR SHALL PRICE THE MORE COSTLY OR EXTENSIVE WORK, UNLESS DIRECTED OTHERWISE. 4. THE CONTRACTOR SHALL SUPERVISE AND DIRECT THE PROJECT DESCRIBED IN THE CONTRACT DOCUMENTS. THE CONTRACTOR SHALL BE SOLELY RESPONSIBLE FOR ALL CONSTRUCTION MEANS,METHODS, TECHNIQUES, SEQUENCES, AND PROCEDURES FOR COORDINATING ALL PORTIONS OF THE WORK UNDER THE CONTRACT. 5. THE CONTRACTOR SHALL INSTALL ALL EQUIPMENT AND MATERIALS ACCORDING TO MANUFACTURER'SNENDOR'S SPECIFICATIONS UNLESS NOTED OTHERWISE OR WHERE LOCAL CODES OR ORDINANCES TAKE PRECEDENCE. 6. ALL WORK PERFORMED ON THE PROJECT AND MATERIALS INSTALLED SHALL BE IN STRICT ACCORDANCE WITH ALL APPLICABLE CODES, REGULATIONS, AND ORDINANCES. CONTRACTOR SHALL GIVE ALL NOTICES AND COMPLY WITH ALL LAWS, ORDINANCES, RULES. REGULATIONS AND LAWFUL ORDERS OF ANY PUBLIC AUTHORITY, MUNICIPAL AND UTILITY COMPANY SPECIFICATIONS, AND LOCAL AND STATE JURISDICTIONAL CODES BEARING ON THE PERFORMANCE OF THE WORK. 7. GENERAL CONTRACTOR SHALL PROVIDE, AT THE PROJECT SITE, A FULL SET OF CONSTRUCTION DOCUMENTS UPDATED WITH THE LATEST REVISIONS AND ADDENDA OR CLARIFICATIONS FOR USE BY ALL PERSONNEL INVOLVED WITH THE PROJECT. THIS SET IS A VALID CONTRACT DOCUMENT ONLY IF THE TITLE SHEET IS STAMPED "FOR CONSTRUCTION" AND EACH SUCCESSIVE SHEET BEARS THE ARCHITECT'S SIGNED WET STAMP. 8. THE STRUCTURAL COMPONENTS OF ADJACENT CONSTRUCTION OR FACILITIES ARE NOT TO BE ALTERED BY THIS CONSTRUCTION PROJECT UNLESS NOTED OTHERWISE. 9. SEAL ALL PENETRATIONS THROUGH FIRE -RATED AREAS WITH U.L. LISTED OR FIRE MARSHALL APPROVED MATERIALS IF APPLICABLE TO THIS FACILITY AND OR PROJECT SITE. 10. CONTRACTOR TO PROVIDE A PORTABLE FIRE EXTINGUISHER WITH A RATING OF NOT LESS THAN 2-A OR 2-Al0BC WITHIN 75 FEET TRAVEL DISTANCE TO ALL PORTIONS OF PROJECT AREA DURING CONSTRUCTION. 11. CONTRACTOR SHALL MAKE NECESSARY PROVISIONS TO PROTECT EXISTING IMPROVEMENTS, EASEMENTS, PAVING, CURBING, ETC. DURING CONSTRUCTION. UPON COMPLETION OF WORK, CONTRACTOR SHALL REPAIR ANY DAMAGE THAT MAY HAVE OCCURRED DUE TO CONSTRUCTION ON OR ABOUT THE PROPERTY. 12. CONTRACTOR SHALL KEEP GENERAL WORK AREA CLEAN AND HAZARD FREE DURING CONSTRUCTION AND DISPOSE OF ALL DIRT, DEBRIS. AND RUBBISH. CONTRACTOR SHALL REMOVE EQUIPMENT NOT SPECIFIED AS REMAINING ON THE PROPERTY OR PREMISES. SITE SHALL BE LEFT IN CLEAN CONDITION AND FREE FROM PAINT SPOTS, DUST, OR SMUDGES OF ANY NATURE. 13, THE GENERAL CONTRACTOR SHALL RECEIVE WRITTEN AUTHORIZATION TO PROCEED WITH CONSTRUCTION PRIOR TO STARTING WORK ON ANY ITEM NOT CLEARLY DEFINED BY THE CONSTRUCTION DRAWINGS/CONTRACT DOCUMENTS. 14. THE CONTRACTOR SHALL PERFORM WORK DURING OWNER'S PREFERRED HOURS TO AVOID DISTURBING NORMAL BUSINESS. 15. THE CONTRACTOR SHALL PROVIDE AT&T WIRELESS, LLC. PROPER INSURANCE CERTIFICATES NAMING AT&T WIRELESS, LLC. AS ADDITIONAL INSURED, AND AT&T WIRELESS, LLC. PROOF OF LICENSE(S) AND PE & PD INSURANCE. 16. CONTRACTOR SHALL BE RESPONSIBLE FOR SCHEDULING AND COORDINATING ALL INSPECTIONS. 17, CAUTION! CALL BEFORE YOU DIG! BURIED UTILITIES EXIST IN THE AREA AND UTILITY INFORMATION SHOWN MAY NOT BE COMPLETE. CONTACT THE ONE -CALL UTILITY LOCATE SERVICE A MINIMUM OF 48 HOURS PRIOR TO CONSTRUCTION, DIAL 811 18. CONTRACTOR TO DOCUMENT ALL WORK PERFORMED WITH PHOTOGRAPHS AND SUBMIT TO AT&T WIRELESS, LLC. ALONG WITH REDLINED CONSTRUCTION SET. 19. CONTRACTOR TO DOCUMENT ALL CHANGES MADE IN THE FIELD BY MARKING UP (REDLINING) THE APPROVED CONSTRUCTION SET AND SUBMITTING THE REDLINED SET TO AT&T WIRELESS, LLC. UPON COMPLETION. 20. FOR COLLOCATION SITES: CONTACT TOWER OWNER REPRESENTATIVE FOR PARTICIPATION IN BID WALK. 21. GENERAL CONTRACTOR IS TO COORDINATE ALL POWER INSTALLATION WITH POWER COMPANY AS REQUIRED. CONTRACTOR TO REPORT POWER INSTALLATION COORDINATION SOLUTIONS) TO NETWORK CARRIER REPRESENTATIVE, PROJECT CONSTRUCTION MANAGER AND ARCHITECT. 22. ANY SUBSTITUTIONS OF MATERIALS AND/OR EQUIPMENT, MUST BE APPROVED BY AT&T CONSTRUCTION MANAGER. 23. IN THE CASE OF ROOFTOP SOLUTIONS FOR EQUIPMENT AND/OR ANTENNA FRAMES WHERE PENETRATION OF EXISTING ROOFING MATERIALS OCCUR, THE GENERAL CONTRACTOR SHALL COORDINATE WITH BUILDING OWNER AND BUILDING ROOFING CONTRACTOR OF RECORD FOR INSTALLATION, PATCH, REPAIR OR ANY AUGMENTATION TO THE ROOF, AND HAVE THE WORK GUARANTEED UNDER THE ROOFING CONTRACTOR'S WARRANTY FOR MOISTURE PENETRATION OR AND OTHER FUTURE BREACH OF ROOFING INTEGRITY. 24. IN THE CASE OF ROOFTOP SOLUTIONS WITH THE INSTALLATION OF ANTENNAS WITHIN CONCEALED (SHROUDED) SUPPORT FRAMES OR TRIPODS, THE GENERAL CONTRACTOR SHALL COORDINATE WITH THE FRP DESIGN ER/FABRICATOR TO ENSURE THAT THE FINAL FRP SHROUD IS SIMULATING (IN APPEARANCE) DESIGNATED EXISTING EXTERIOR BUILDING FACADE MATERIALS, TEXTURES, AND COLORS. THE CONTRACTOR SHALL FURTHERMORE ENSURE THE USE OF COUNTERSUNK FASTENERS IN ALL FRP CONSTRUCTION. WHEN PHOTO SIMULATIONS ARE PROVIDED. THE CONTRACTOR SHALL ENSURE THAT FINAL CONSTRUCTION REPRESENTS WHAT IS INDICATED IN PHOTO SIMULATIONS. SHOP DRAWINGS SHALL BE PROVIDED TO THE GENERAL CONTRACTOR, CONSTRUCTION COORDINATOR, AND ARCHITECT PRIOR TO FABRICATION AND CONSTRUCTION. GENERAL NOTES (CONT'L ). 25. IN THE CASE OF ROOFTOP SOLUTIONS FOR EQUIPMENT AND/OR ANTENNA FRAMES WHERE ANCHORING TO A CONCRETE ROOF SLAB IS REQUIRED, CONTRACTORS SHALL CONFIRM (PRIOR TO SUBMITTING BID) WITH CONSULTING CONSTRUCTION COORDINATOR AND ARCHITECT THE PRESENCE OF POST TENSION TENDONS WITHIN THE ROOF SLAB - RESULTING FROM AN UNDOCUMENTED DESIGN CHANGE IN THE EXISTING BUILDING "AS -BUILT DRAWING SET" -HAVING INDICATED AN ORIGINAL DESIGN SOLUTION OF REINFORCED CONCRETE W/EMBEDDED STEEL REBAR. IN THE EVENT POST TENSION SLAB SOLUTION IS PRESENT, CONTRACTOR SHALL INCLUDE PROVISIONS FOR X-RAY PROCEDURES (INCLUDED IN BID) FOR ALL PENETRATION AREAS WHERE ANCHORING OCCURS. 26, GENERAL & SUB CONTRACTORS SHALL USE STAINLESS STEEL METAL LOCKING TIES FOR ALL CABLE TRAY TIE DOWNS AND ALL OTHER GENERAL TIE DOWNS (WHERE APPLICABLE). PLASTIC ZIP TIES SHALL NOT BE PERMITTED FOR USE ON AT&T PROJECTS. RECOMMENDED MANUFACTURE SHALL BE: PANDUIT CORP. METAL LOCKING TIES MODEL NO. MLT4S-CP UNDER SERIES-304 (OR EQUAL). PANDUIT PRODUCT DISTRIBUTED BY TRIARC OF TACOMA, WA. DESIGN CRITERIA: 1. THE STRUCTURAL DESIGN OF THIS PROJECT IS IN ACCORDANCE WITH THE INTERNATIONAL BUILDING CODE 2009 WITH WASH INGTON STATE BUILDING CODE AMENDMENTS (IBC 2009) 2. DESIGN LOADS: DESIGN DATA FOR KING COUNTY, WA: -ROOF SNOW LOAD N/A (NOT A ROOFTOP SOLUTION) -BASIC WIND SPEED 85 MPH (3 SEC GUST) -WIND EXPOSURE B CONCRETE NOTES: 1. ALL CONCRETE CONSTRUCTION SHALL BE IN ACCORDANCE WITH ACI-318. 2. CONCRETE SHALL BE MIXED, PROPORTIONED, CONVEYED AND PLACED IN ACCORDANCE WITH CHAPTER 19 OF THE IBC 2009. STRENGTHS AT 28 DAYS AND MIX CRITERIA SHALL BE AS FOLLOWS. TYPE OF CONSTRUCTION 28 DAY STRENGTHS W/C MINIMUM (fc) RATIO CONT A, SLABS ON GRADE PER CUBI TOPPING SLABS CONCRETE PIERS 3,000 PSI f .45 5 1/2 SA B. ALL STRUCTURAL CONCRETE 4,000 PSI � .45 6 112 SA EXCEPT WALLS C. CONCRETE WALLS 4,000 PSI '_ .45 6 1/2 SA CEMENT SHALL BE ASTM C150, PORTLAND CEMENT TYPE 0 U.N.O. 3. THE GENERAL CONTRACTOR SHALL SUPERVISE AND BE RESPONSIBLE FOR THE METHODS AND PROCEDURES OF CONCRETE PLACEMENT. 4. ALL CONCRETE WITH SURFACES EXPOSED TO STANDING WATER SHALL BE AIR -ENTRAINED WITH AN AIR -ENTRAINING AGENT CONFORMING TO ASTM C260, C494, C618. C989 AND C1017. TOTAL AIR CONTENT SHALL BE IN ACCORDANCE WITH TABLE 1904.2.1 OF THE IBC 2009. 5, REINFORCING STEEL SHALL CONFORM TO ASTM A615 (INCLUDING SUPPLEMENT Si), GRADE 60, fy=60,000 PSI. EXCEPTIONS: ANY BARS SPECIFICALLY SO NOTED ON THE DRAWINGS SHALL BE GRADE 40. fy=40.000 PSI. GRADE 60 REINFORCING BARS INDICATED ON DRAWINGS TO BE WELDED SHALL CONFORM TO ASTM A706. REINFORCING COMPLYING WITH ASTM A615(S1) MAY BE WELDED ONLY IF MATERIAL PROPERTY REPORTS INDICATING CONFORMANCE WITH WELDING PROCEDURES SPECIFIED IN A.W.S. D14 ARE SUBMITTED. 6. REINFORCING STEEL SHALL BE DETAILED (INCLUDING HOOKS AND BENDS) IN ACCORDANCE WITH ACI 315 AND 318. LAP ALL CONTINUOUS REINFORCEMENTAT LEAST 30 BAR DIAMETERS OR A MINIMUM OF 2'-0'. PROVIDE CORNER BARS AT ALL WALL AND FOOTING INTERSECTIONS. LAP CORNER BARS AT LEAST 30 BAR DIAMETERS OR A MINIMUM OF 2'-0". LAP ADJACENT MATS OF WELDED WIRE FABRIC A MINIMUM OF B" AT SIDES AND ENDS. 7. WELDED WIRE FABRIC SHALL CONFORM TO ASTM A-185. 8. SPIRAL REINFORCEMENT SHALL BE PLAIN WIRE CONFORMING TO ASTM A615. GRADE 60. fy=60.000 PSI. 9, NO BARS PARTIALLY EMBEDDED IN HARDENED CONCRETE SHALL BE FIELD BENT UNLESS SPECIFICALLY SO DETAILED OR APPROVED BY THE CONSULTANT. 10. CONCRETE PROTECTION (COVER) FOR REINFORCING STEEL SHALL BE AS FOLLOWS: FOOTINGS AND OTHER UNFORMED SURFACES, EARTH FACE 3" - FORMED SURFACES EXPOSED TO EARTH OR WEATHER (#6 BARS OR LARGER) 2" (#5 BARS OR SMALLER) 1 1/2" - SLABS AND WALLS (INTERIOR FACE) 3/4" 11. BARS SHALL BE SUPPORTED ON CHAIRS OR DOBIE BRICKS. 12, ANCHOR BOLTS TO CONFORM TO ASTM A307. 13. NON -SHRINK GROUT SHALL BE FURNISHED BY AN APPROVED MANUFACTURER AND SHALL BE MIXED AND PLACED IN STRICT ACCORDANCE WITH THE MANUFACTURER'S PUBLISHED RECOMMENDATIONS. GROUT STRENGTH SHALL BE AT LEAST EQUAL TO THE MATERIAL ON WHICH IT IS PLACED (3,000 PSI MINIMUM), 14. ALL EXPANSION ANCHORS TO BE HILTI BRAND. ADHESIVE ANCHORS REQUIRE TESTING TO CONFIRM CAPACITY UNLESS WAIVED BY ENGINEER. LENIENT ENT C YARD CKS CKS CKS STRUCTURAL STEEL NOTES: 1. SHOP DRAWINGS FOR STRUCTURAL STEEL SHALL BE SUBMITTED TO THE CONSULTANT FOR REVIEW PRIOR TO FABRICATION. 2. STRUCTURAL STEEL DESIGN, FABRICATION AND ERECTION (INCLUDING FIELD WELDING, HIGH STRENGTH FIELD BOLTING, EXPANSION BOLTS. AND THREADED EXPANSION ANCHORS) SHALL BE BASED ON THE A.I.S.I. "SPECIFICATION FOR THE DESIGN, FABRICATION, AND ERECTION OF STRUCTURAL STEEL FOR BUILDINGS" LATEST EDITION. SUPERVISION SHALL BE IN ACCORDANCE WITH IBC 2009 CHAPTER 22. BY A QUALIFIED TESTING AGENCY DESIGNATED BY THE CONSULTANT. THE CONSULTANT SHALL BE FURNISHED WITH A COPY OF ALL INSPECTION REPORTS AND TEST RESULTS. 3. STRUCTURAL STEEL SHALL CONFORM TO THE FOLLOWING REQUIREMENTS: TYPE OF MEMBER A. WIDE FLANGE SHAPE ASTM A992, Fy 50 KSI B. OTHER SHAPE. PLATES AND ROD ASTM A36, Fy 36 KS I E PIPE COLUMNS ASTM A53, Fy 35 KSI D. STRUCTURAL TUBING ASTM A500, Fy 46 KSI E. ANCHOR BOLTS ASTM A307 Fm CONNECTION BOLTS ASTM A325 4. ALL MATERIAL TO BE HOT DIPPED GALVANIZED AFTER FABRICATION PER A123/A123M-00. 5. ALL WELDING SHALL BE IN CONFORMANCE WITH A.I.S.I. AND AWS STANDARDS AND SHALL BE PERFORMED BY W.A.B.O. CERTIFIED WELDERS USING E70 XX ELECTRODES. ONLY PREQUALIFIED WELDS (AS DEFINED BY AWS)SHALL BE USED. WELDING OF GRADE 60 REINFORCING BARS (IF REQUIRED) SHALL BE PERFORMED USING LOW HYDROGEN ELECTRODES. WELDING OF GRADE 40 REINFORCING BARS (IF REQUIRED) SHALL BE PERFORMED USING E70 XX ELECTRODES. WELDING WITHIN 4' OF COLD BENDS IN REINFORCING STEEL IS NOT PERMITTED. SEE REINFORCING NOTE FOR MATERIAL REQUIREMENTS OF WELDED BARS, 6. COLD -FORMED STEEL FRAMING MEMBERS SHALL BE OF THE SHAPE, SIZE, AND GAGE SHOWN ON THE PLANS. PROVIDE MINIMUM SECTION PROPERTIES INDICATED. ALL COLD -FORMED STEEL FRAMING SHALL CONFORM TO THE A.I.S.I. "SPECIFICATION FOR THE DESIGN OF COLD -FORMED STEEL STRUCTURAL MEMBERS.' 7. BOLTED CONNECTIONS SHALL USE BEARING TYPE ASTM A325 BOLTS (3/4" DIA.)AND SHALL HAVE A MINIMUM OF TWO BOLTS UNLESS NOTED OTHERWISE. 8, NONSTRUCTURAL CONNECTIONS FOR STEEL GRATING MAY USE 5/8" DIA. ASTM A307 BOLTS UNLESS NOTED OTHERWISE. 9. ALL STEEL WORK SHALL BE PAINTED IN ACCORDANCE WITH THE DESIGN & CONSTRUCTION SPECIFICATION AND IN ACCORDANCE WITH ASTM A36 UNLESS NOTED OTHERWISE. 10, ALL WELDS TO BE 1/4" FILLET UNLESS NOTED OTHERWISE. 11. TOUCH UP ALL FIELD DRILLING AND WELDING WITH 2 COATS OF GALVACON (ZINC RICH PAINT) OR APPROVED EQUAL. TOWER/POLE NOTES: 1. VERIFICATION THAT THE PROPOSED TOWER/POLE CAN SUPPORT THE PROPOSED ANTENNA LOADING IS TO BE DONE BY OTHERS. 2. PROVIDE SUPPORTS FOR THE ANTENNA COAX CABLES TO THE ELEVATION OF ALL INITIAL AND FUTURE ANTENNAS. ANTENNA COAX CABLES ARE TO BE SUPPORTED AND RESTRAINED AT THE CENTERS SUITABLE TO THE MANUFACTURER'S REQUIREMENTS. ABBREVIATED ROOF TOP SAFETY PROCEDURES (WHEN APPLICABLE): (AS PER "ACCIDENT PREVENTION PROGRAM"- BY PERMISSION OF WREN CONSTRUCTION, INC. - 03/01/99) FALL PROTECTION METHODS AND EQUIPMENT ROOFTOP INSTALLATIONS 1. FOR WORK IS BEING PERFORMED WITHIN 25' OF AN UNPROTECTED ROOF EDGE, THE CONSTRUCTION SUPERVISOR SHALL DESIGNATE A TRAINED SAFETY MONITOR TO OBSERVE THE MOVEMENTS AND ACTIVITIES OF THE CONSTRUCTION WORKERS. 2. SAFETY MONITOR SHALL WARN CONSTRUCTION WORKERS OF HAZARDS (I.E., BACKING UP TOWARD A ROOF EDGE, ETC.) OR UNSAFE ACTIVITIES. THE SAFETY MONITOR MUST BE ON THE SAME ROOF AND WITHIN VISUAL AND VERBAL DISTANCE OF THE CONSTRUCTION WORKERS. 3. CONSTRUCTION INVOLVING WORKERS TO APPROACH WITHIN 6' OR LESS OF AN UNPROTECTED ROOF EDGE, REQUIRES WORKERS TO USE SAFETY LINE. 4. SAFETY LINE SHALL BE MINIMUM IA' DIAMETER NYLON, WITH A NOMINAL TENSILE STRENGTH OF 5400 LBS. S. SAFETY LINE SHALL BE ATTACHED TO A SUBSTANTIAL MEMBER OF THE STRUCTURE. 6. SAFETY LINE LENGTH SHALL BE SET ALLOWING CONSTRUCTION WORKER TO REACH EDGE OF ROOF, BUT NOT BEYOND. 7. SAFETY BELTS SHALL BE WORN BY ALL CONSTRUCTION WORKERS. B. MONTHLY SAFETY INSPECTION AND MAINTENANCE OF THE FALL PROTECTION EQUIPMENT SHALL OCCUR BY THE SAFETY COMMITTEE REPRESENTATIVES, INCLUDING: INSPECTION OF CONSTRUCTION AREA FOR HAZARDS USE OF AN INSPECTION CHECKLIST INTERVIEWING COWORKERS REGARDING SAFETY CONCERNS REPORTING AND DOCUMENTING ANY HAZARDS REPORTING HAZARDS TO THE SAFETY COMMITTEE FOR CONSIDERATION POSTING RESULTS OF INSPECTION AND ANY ACTION TAKEN RECEIVING AN UNBIASED REVIEW OF ONE'S OWN WORK AREA BY ANOTHER COWORKER SAFETY REPRESENTATIVE REFER TO ROOFTOP WORK AREA SAFETY PROTOCOL NATIONAL ASSOCIATION OF TOWER ERECTORS 2000 PUBLICATION REFERENCED OSHA REGULATION/STANDARDS SHALL BE REVIEWED BY TOWER ERECTORS, EQUIPMENT INSTALLERS, AND TOWER/ROOF TOP CONTRACTORS/SUBCONTRACTORS 29 CFR 1926.500-SCOPE, APPLICATION, AND DEFINITIONS 29 CFR 1926.501 - DUTY TO HAVE FALL PROTECTION 19 CFR 1026.502 - FALL PROTECTION SYSTEMS CRITERIA AND PRACTICES SYMBOL., AND ABBREVIATIONS A/C AIR CONDITIONING LBS POUNDS AGL ABOVE GRADE LEVEL MAX MAXIMUM APPROX APPROXIMATELY MECH MECHANICAL MTL METAL BLDG BUILDING MFR MANUFACTURE BLK BLOCKING MGR MANAGER MIN MINIMUM CLG CEILING MISC MISCELLANEOUS CLR CLEAR CONC CONCRETE NA NOT APPLICABLE CONST CONSTRUCTION NIC NOT IN CONTRACT CONT CONTINUOUS NS NEAR SIDE NTS NOT TO SCALE DBL DOUBLE DIA DIAMETER OC ON CENTER DIAG DIAGONAL OD OUTSIDE DIAMETER DN DOWN DET DETAIL PLYWD PLYWOOD DWG DRAWING PROJ PROJECT PROP PROPERTY EA EACH PT PRESSURE TREATED EL ELEVATION RED REQUIRED ELEC ELECTRICAL RM ROOM ED EQUAL RO ROUGH OPENING EQUIP EQUIPMENT EXT EXTERIOR SHT SHEET SIM SIMILAR FIN FINISH SPEC SPECIFICATION FLUOR FLUORESCENT SF SQUARE FOOT FLR FLOOR SS STAINLESS STEEL FS FAR SIDE STL STEEL FT FOOT STRUCT STRUCTURAL STD STUD GA GAUGE SUSP SUSPENDED GALV GALVANIZED GC GENERAL CONTRACTOR THRU THROUGH GRNO GROUND TNNG TINNED GYPBD GYPSUM WALLBOARD TYP TYPICAL HORZ HORIZONTAL UNO UNLESS NOTED HR HOUR OTHERWISE HT HEIGHT HVAC HEATING VERT VERTICAL VENTILATION VIF VERIFY IN FIELD AIR CONDITIONING W/ WITH ID INSIDE DIAMETER W/O WITHOUT IN INCH WP WATERPROOF INFO INFORMATION INSUL INSULATION INT INTERIOR IBC INTERNATIONAL BUILDING CODE - T T- TELEPHONE -p P- POWER - - - - - - - - - - - GROUND WIRE -COAX COAX- COAXIAL CABLE ANTENNA rL CENTERLINE (E) EXISTING ex DETAIL NUMBER SHEET NUMBER SPECIAL INSPECTIONS: SPECIAL INSPECTIONS IN ACCORDANCE WITH IBC 2009 SECTION 1704. SOILS/GEOTECHNICAL: ❑SHORING INSTALLATION AND MONITORING ❑OBSERVE AND MONITOR EXCAVATION ❑VERIFY SOIL BEARING psf BEARING []SUBSURFACE DRAINAGE PLACEMENT ❑ VERIFY FILL MATERIAL AND COMPACTION ❑ VERIFY CONDITIONS AS ANTICIPATED ❑PILE PLACEMENT (AUGER CAST/DRIVEN PILE) ❑OTHER REINFORCED CONCRETE: ❑REINFORCING STEEL AND CONCRETE PLACEMENT ❑PRESTRESSED/PRECAST CONCRETE FABRICATION AND ERECTION ❑BATCH PLANT INSPECTION ❑SHOTCRETE ❑GROUTING ❑OTHER STRUCTURAL STEEL: ❑FABRICATION AND SHOP WELDS ❑ERECTION AND FIELD WELDS AND BOLTING ❑OTHER at&t Your world. Delivered. rRVJCVI VVIVJVLIMIVIJ. QGoodmanNetworks PLANS PREPARED BY: -� OFlNERS TONE 1692E WOODINVILLE-REDMOND RD NE, SUITE 210 WOODINVILLE, WA 98072 PHONE: 425.487.1732 FAX:425.487.1734 EMAIL: cei@cornerstone ngr. m W W W.CORNERSTONE-ENGR.COM r PROJECT INFO: L ISSUED FOR: CCONSTRUCTION rREV:=DATE:=ISSUED FOR: BY:� Qp 08-31-11 CONSTRUCTION JRS 1 06-30-11 I CLIENT REVIEW tAJB LDRAWN BY:=CHK.: APV.: rAJB I BMH MWO L CURRENT ISSUE DATE: CI I!`GNICI ICG• 08-31-11 DO NOT SCALE DRAWINGS. CONTRACTOR MUST VERIFY STRUCTURAL ALUMINUM: ALL DIMENSIONS AND ADVISE CONSULTANTS OF ANY ERRORS AND OMISSIONS. ALL PREVIOUS ISSUES OF THIS ❑FABRICATION AND SHOP WELDS DRAWING ARE SUPERSEDED BY THE LATEST REVISION. ❑ERECTION AND FIELD WELDS AND BOLTING ❑OTHER THE INFORMATION CONTAINED IN THIS SET OF DOCUMENTS IS PROPRIETARY BY NATURE. ANY USE OR DISCLOSURE OTHER THAN WHICH IS RELATED TO NAMED CLIENT IS STRICTLY PROHIBITED. STRUCTURAL MASONRY: DRAWING TITLE: ❑CONTINUOUS ❑PERIODIC GENERAL NOTES OTHER: rDRAWING NUMBER: ANCHORING TO CONCRETE: t ❑BOLOLTS INSTALLED IN CONCRETE ^ I (vl+ 0 ❑POST -INSTALLATION ADHESIVE ANCHORS � 1 _-I ❑POST -INSTALLATION MECHANICAL ANCHORS CEI JOB NUMBER: 11-69043 r \ \ (E) CHAINLINV \ m 10 \\N \NGRes s C b \ \ O \O \N \ (E) TREES SITE PLAN TL# 0423049186 \ SITE ACCESS i � 2 \ \ (E) 156'-8" HIGH SCL \ \ \ SELF-SUPPORT LATTICE TOWER \ ED THIS IS NOT A SURVE . ALL INFORMATION AND TRUE NORTH HAVE BEEN OBTAINED FROM EXISTING DRAWINGS AND ARE APPROXIMATE. (E) PARKING LOT 1. N N1,1 "'_� - (E) AT&T EQUIPMENT COMPOUND SUBJECT ZONING USE: INDUSTRIAL ZONE: MIC/H ADJACENT ZONING USE: INDUSTRIAL \ ZONE: MIC/H \ \ \ TL# 0423049189 \ \ SCL TRANSMISSION TOWER ROW TL# 0423049130 \ 822,899 SQ. FT. \ (18.89 ACRES) (E) UTILITY POLE (TYP) (E) CONCRETE CURB (TYP) \ C � at&t Your world. Delivered. � PROJECT CONSULTANTS: GoodmanNetworks PLANS PREPARED BY: CCORNER640NE �• oir+eew�Ho. �Ne. 18923 WOODINVILLE-REDMOND RD NE, SUITE 210 WOODINVILLE, WA 95072 PHONE: 425.487.1732 FAX: 425.487.1734 EMAIL: cei@cornersto­rgr.com W W W.CORNERSTONE-ENGR.COM .,PROJECT INFO: L ISSUED FOR: � CCONSTRUCTION REV: =DATE:=ISSUED FOR: BY: DRAWN BY: =CHK.: APV.: AJB BMH CURRENT ISSUE DATE: MWO [08-31-11 _ LICENSURE: 0 08-31-11 CONSTRUCTION JRS Qq 06-30-11 CLIENT REVIEW AJB ;DRAWING INFORMATION: DO NOT SCALE DRAWINGS. CONTRACTOR MUST VERIFY ALL DIMENSIONS AND ADVISE CONSULTANTS OF ANY ERRORS AND OMISSIONS. ALL PREVIOUS ISSUES OF THIS DRAWING ARE SUPERSEDED BY THE LATEST REVISION. THE INFORMATION CONTAINED IN THIS SET OF DOCUMENTS IS PROPRIETARY BY NATURE. ANY USE OR DISCLOSURE OTHER THAN WHICH IS RELATED TO NAMED CLIENT IS STRICTLY PROHIBITED. \ 'DRAWING TITLE: (E) PARKING LOT \ SITE PLAN DRAWING NUMBER: PLAN NORTH Al 0 CEI JOB NUMBER: 11-69043 1" = 20'-0" 111x17 SCALE: 1" _ (E) CHAIN -LINK FENCE W/ BARBED WIRE (E) SCL SELF-SUPPORT LATTICE TOWER r FOOTING (TYP) P 7, (E) TELCO ENCLOSURE (E) UMTS CABINET (E) 100 AMP ELECTRICAL SERVICE PANEL W/ METER & SERVICE LIGHT (E) MICRIN GEN PLUG (E)200AMP r' ELECTRICAL SERVICE (E) ICE CANOPY (ABOVE) (E) 24" WIDE ICE BRIDGE (E) TE21 POWER CABINET (E) NOKIA CABINET r i (E) TE40 CABINET PROPOSED U/G 2"0 RIGID 24V DC POWER CONDUIT FROM (E) TE21 TO (E) TE43 / PROPOSED AT&T L G P S ANTENNA �a NOTE: EXISTING SCL SELF-SUPPORT LATTICE TOWER & AT&T PANEL ANTENNA ARRAY NOT SHOWN FOR CLARITY NOTE: SEE RF-1 FOR ANTENNA PLAN (E) CHAIN -LINK FENCE W/ BARBED WIRE & PRIVACY SLATS 66 (E) ICE BRIDGE W/ (12) 7/8"0 COAX (E) �• / & (6) 1 5/8" 0 COAX � 4e , ., ....ter•.. � rPOSED H-FRAME W/ LTE BACKPACK, SURGE BOX PRESSOR ENCLOSURE &ESS CABLE ENCLOSURE A 3 1 DC POWER TRUNK CABLES ACKPACK, THROUGH SURGE SUPPRESSOR, TO NEMATYPE. (E) H-FRAME W/ (6) DIPLEXERS PROPOSED FIBER CABLE FROM LTE 9412 BACKPACK TO NEMA TYPE 3 BOX PROPOSED H-FRAME W/ (3) 700MHz & (3) 2100MHz RRH'S, (2) CABLE GUTTERS, (2) NEMA TYPE 3 BOXES & (6) DIPLEXERS 11 (E) H-FRAME W/ HOFFMAN BOX A-3.1 A•3 PROPOSED DC -DC CONVERTER 9 (E) TE43 CABINET MOUNTED WITHIN (E) TE43 CABINET A-3 PROPOSED FIBER CABLE FROM (E) TE43 TO LTE 9412 BACKPACK PROPOSED (2) 48V DC POWER TRUNK CABLES FROM (E) TE43 TO LTE 9412 BACKPACK 0 PROPOSED ENLARGED SITE PLAN (E) CONCRETE CURB (TYP) (E) LIGHT POLE PLAN NORTH (E) CHAIN -LINK FENCE W/ BARBED WIRE (E) SCL SELF-SUPPORT LATTICE TOWER FOOTING (TYP) o P� ^6G�74 (E) TELCO ENCLOSURE (E) UMTS CABINET (E) 100 AMP ELECTRICAL SERVICE PANEL W/ METER & SERVICE LIGHT (E) MICRIN GEN PLUG (E) 200 AMP ELECTRICAL SERVICE (E) ICE CANOPY (ABOVE) (E) 24" WIDE ICE BRIDGE (E) TE21 POWER CABINET (E) NOKIA CABINET (E) TE40 CABINET (E) TE43 CABINET EXISTING ENLARGED SITE PLAN 11x17 SCALE: 1/4" = 1'-0" NOTE: EXISTING SCL SELF-SUPPORT LATTICE TOWER & AT&T PANEL ANTENNA ARRAY NOT SHOWN FOR CLARITY (E) CHAIN -LINK FENCE W/ BARBED WIRE & PRIVACY SLATS (E) ICE BRIDGE W/ (12) 7/8"0 COAX (E) (E) H-FRAME W/ (6) DIPLEXERS (E) H-FRAME W/ HOFFMAN BOX (E) CONCRETE CURB (TYP) (E) LIGHT POLE PLAN NORTH at&t Your world. Delivered. PROJECT CONSULTANTS: GoodmanNetworks PLANS PREPARED BY: [CORNERSTONE _� EN OINEERIN O. INC. 16928 WOODINVILLE-REDMOND RD NE, SUITE 210 WOODINVILLE, WA 98072 PHONE: 425.487.1732 FAX:425.487.1734 EMAIL: cei@cornemtone�ngr.com W W W.CORNERSTONE-ENGR.COM L PROJECT INFO: L ISSUED FOR: CCONSTRUCTION =REV.=DATE:=ISSUED FOR: BY:= Qp 08-31-11 CONSTRUCTION JRS Qq 06-30-11 CLIENT REVIEW AJB DRAWN BY:=CHK.: APV.: AJB 1BMH MWO [CURRENT ISSUE DATE. 08-31-11 r LICENSURE: DRAWING INFORMATION: DO NOT SCALE DRAWINGS. CONTRACTOR MUST VERIFY ALL DIMENSIONS AND ADVISE CONSULTANTS OF ANY ERRORS AND OMISSIONS. ALL PREVIOUS ISSUES OF THIS DRAWING ARE SUPERSEDED BY THE LATEST REVISION. THE INFORMATION CONTAINED IN THIS SET OF DOCUMENTS IS PROPRIETARY BY NATURE. ANY USE OR DISCLOSURE OTHER THAN WHICH IS RELATED TO NAMED CLIENT IS STRICTLY PROHIBITED. DRAWING TITLE: EXISTING & PROPOSED Ll ENLARGED SITE PLANS ,DRAWING NUMBER: A-1.1 0 CEI JOB NUMBER: 11-69043 = V-0" 111x17 SCALE: 1/4" = V-0" T.O. E SCL LATTICE TOWER EL 156-8" AGL E TRANSMISSION LINE EL 134'-2" AGL (E) ANTENNA MOUNT TO TEMPORARILY REMAIN UNTIL REMOVAL CAN BE PERFORMED BY SCL (TYP OF 3 SECTORS) — E TRANSMISSION LINE EL 115'-9" AGL 12'-0" EXCLUSION AREA (TYP) o(E) TRANSMISSION LINE DEL 97'-6" AGL 1 \ T.O. PROPOSED AT&T PANEL ANTE EL 85'-6" AGL �RAD CENTER OF PROPOSED AT&T A - EL 8V-6" AGL PROPOSED AT&T . GPS ANTENNA (E) ICE BRIDGE PROPOSED DC -DC CONVERTER MOUNTED WITHIN (E) TE43 CABINET m „EL 0'-0" (ASSUMED) PROPOSED SOUTHEAST ELEVATION (E) TRANSMISSION LINE EL 155'-7" AGL (E) TRANSMISSION LINE EL 135'-3" AGL (E) PANEL ANTENNA TO TEMPORARILY REMAIN UNTIL REMOVAL CAN BE PERFORMED BY SCL (TYP OF 6) (E) TRANSMISSION LINE EL 116'-10" AGL (E)ITRANSMISSION LINE 19 1 ' EL 98'-6" AGL (E) AT&T ANTENNAS AND MOUNT TO REMAIN (TYP OF 3 SECTORS) PROPOSED AT&T LTE ANTENNA A-3 PROPOSED TWIN TMA MOUNTED TO PIPE MAST 7 (TYP OF 3, 1 PER SECTOR) A-3 PROPOSED (6) 1 5/8- 0 COAX FROM RRH'S TO TMA'S (E) 156'-8" HIGH SCL SELF-SUPPORT LATTICE TOWER (E) VERTICAL COAX SUPPORT TO BE REUSED (TYP) (E) ICE CANOPY PROPOSED H-FRAME W/ (3) 700MHz & (3) 2100MHz RRH'S, (2) CABLE GUTTERS, (2) NEMA 11 TYPE 3 BOXES & (6) DIPLEXERS A-31 (E) EQUIPMENT CABINET (TYP) (E) CHAIN -LINK FENCE W/ BARBED WIRE & PRIVACY SLATS PROPOSED H-FRAME W/ LTE 9412 BACKPACK, SURGE SUPPRESSOR ENCLOSURE & ,- EXCESS CABLE ENCLOSURE A-3.1 (E) ICE BRIDGE W/ (12) 7/8"0 COAX (E) & (6) 1 5/8" 0 COAX PROPOSED OFA .i. T_O. (Fl SCI LATTICE TOWER EXISTING SOUTHEAST ELEVATION 1107 SCALE: 1/16" = I KANoWIR I? LINt EL 155-7" AGL I TRANSMISSION LINE / EL 135'-3" AGL (E) PANEL ANTENNA TO TEMPORARILY REMAIN UNTIL REMOVAL CAN BE PERFORMED BY SCL (TYP OF 6) I TRANSMISSION LINE h EL 116-10" AGL TRANSMISSION LINE EL 98'-6" AGL (E) 156'-8" HIGH SCL SELF-SUPPORT LATTICE TOWER (E) VERTICAL COAX SUPPORT TO BE REUSED (TYP) (E) ICE CANOPY (E) EQUIPMENT CABINET (TYP) (E) CHAIN -LINK FENCE W/ BARBED WIRE & PRIVACY SLATS (E) ICE BRIDGE W/ (12) 7/8"0 COAX C R t' 0.0007 at&t Your world. Delivered. PROJECT CONSULTANTS: GoodmanNetworks PLANS PREPARED BY: _�E CORNERS TONE 16928 WOODINVILLE-REDMOND RD NE, SUITE 210 WOODINVILLE, WA 98072 PHONE: 425.487.1732 FAX:425.487.1734 EMAIL: cei@comerston ngr.com W W W.CORNERSTONE-ENGR.COM r PROJECT INFO: ISSUED FOR: 1 CCONSTRUCTION r,REV:=DATE:=ISSUED FOR: BY:::� Qp 08-31-11 CONSTRUCTION JRS Qq 06-30-11 CLIENT REVIEW AJB DRAWN BY:=CHK.: APV.: AJB BMH MWO CCURRENT ISSUE DATE: 08-31-11 r LICENSURE: 'DRAWING INFORMATION: DO NOT SCALE DRAWINGS. CONTRACTOR MUST VERIFY ALL DIMENSIONS AND ADVISE CONSULTANTS OF ANY ERRORS AND OMISSIONS. ALL PREVIOUS ISSUES OF THIS DRAWING ARE SUPERSEDED BY THE LATEST REVISION. THE INFORMATION CONTAINED IN THIS SET OF DOCUMENTS ISPROPRIETARY BY NATURE, ANY USE OR DISCLOSURE OTHER THAN WHICH IS RELATED TO NAMED CLIENT IS STRICTLY PROHIBITED. DRAWING TITLE: EXISTING & PROPOSED SOUTHEAST ELEVATIONS rDRAWING NUMBER: A-2 0 CEI JOB NUMBER: 11-69043 22x34 SCALE: 1/8" = 1'-0" 111x17 FINISH GRADE OR PAVING TO MATCH SLOPE OF EXISTING GRADE 2'-0" EXCAVATION WARNING TAPE UNEXCAVATED AREA NOTE: VERIFY ALL TRENCHING REQUIREMENTS PER LOCAL UTILITIES. COMPACTED BACK FILL PER WSDOT 9-03.14(3) COMPACTED TO MIN UNIT WT PER ASTM D1557 FIBER OPTIC TRUNK LINE WITHIN 1 1/2"0INNERDUCT (2) POWER TRUNK LINES (1) 4" SCH 40 PVC CONDUIT PIPE ZONE BEDDING PER WSDOT 9-03.12(3) COMPACTED TO MIN 95% OF MAX UNIT WT PER ASTM D1557 POWER / FIBER TRENCH 22x34 SCALE: 1/2" = 1'-01, 11x17 SCA NOT USED 22x34 SCALE: NTS I11x17 SCA moll r 1 •, I TOP 2100MHz RRH 22x34 SCALE: 1 1/2" = 1'-0" 12 1 NOT USED I 22x34 SCALE: NTS 0) 11x17 MAKE: POWERWAVE MODEL: TTAW-07BP111-001 HEIGHT: 9.9" WIDTH: 6.7" DEPTH: 5.4" W 0i 5.4" 8 1TWIN TMA DETAIL 22x34 SCALE: 3" = V-0" I11x17 MANUFACTURER: ALCATEL-LUCENT MODEL: 9442 RRH AWS 2100MHz HEIGHT: 24.4" WIDTH: 10.6" DEPTH: 6.T' WEIGHT: 43 LBS 11x17 SCALE: 3/4" = 1'-0" t•� NOT USED 22x34 SCALE: NTS 11x17 SCALE: NTS AT&T GPS ANTENNA 1 7/8" O.D. PIPE RLSS PIPE TO PIPE CLAMP SET U) (PARTg10-158-001) O NOTES: 1. LOCATION OF ANTENNA MUST HAVE CLEAR VIEW OF SOUTHERN SKY AND CANNOT HAVE ANY BLOCKAGES EXCEEDING 25% OF THE SURFACE AREA OF A HEMISPHERE AROUND THE GPS ANTENNA. 2. ALL GPS ANTENNA LOCATIONS MUST BE ABLE TO RECEIVE CLEAR SIGNALS FROM A MINIMUM OF FOUR (4) SATELLITES. VERIFY WITH HANDHELD GPS BEFORE FINAL LOCATION OF GPS ANTENNA. 11 LTE GPS ANTENNA 10 22x34 SCALE: 1" = V-0" 111x17 SCALE: 112" = T-0" MAKE: POWERWAVE MODEL: CM1007-DBPXBC HEIGHT: 8.96" WIDTH: 4.92" DEPTH: 3.2T' Qo oQ co- - m AOWERW.4VE pWOD M 4.92" 0 0 L32 7 DIPLEXER DETAIL 6 22x34 SCALE: 3" = T-0" 111x17 SCALE: 1 1/2" = V-0" 11.8" 6" fV N FRONT VIEW SIDE VIEW BACK VIEW ANTENNA: KATHREIN 800 10764 TOP VIEW 3 I ANTENNA DETAIL (SECTOR Y) 2 r ■aaaaaaaaeaaaaaaaaaa■, - B 9 6�at&t Your world. Delivered. TOP DISTRIBUTION SHELF PROJECT CONSULTANTS: (18 BREAKER POSITIONS) 0o MANUFACTURERALPHA TECHNOLOGIES G d N fiA/ MC e ' v "O o 0 oo man e o s MODEL: 24V/48V DC -DC CONVERTER •• • - •• •" ARGUS P/N: 053-996-20-000 HEIGHT: 8.75"; 5RU (Rack Units) WIDTH: 17.24"; 19"/23" RACK MOUNTS PLANS PREPARED BY: DEPTH: 12.20" WEIGHT: 45 LBS FRONT 0 a ao NEFlS TONE CONVERTER SHELF (SPACE FOR UP TO 4 16928 WOODINVILLE-REDMOND RD NE, SUITE 210 CONVERTER POSITIONS) WOODINVILLE, WA 98072 PHONE: 425.487.1732 FAX:425.487.1734 EMAIL: cei@cornerston rgr.com IF W WW.CORNE RS70NE{NGR.COM PROJECT INFO: DC -DC CONVERTER 9 WA158 22x34 SCALE: 1 1/2" = 1.4. 11x17 SCALE: 3/4" = T-0" ROXBURY FRONT SOLAR 12 19/32" SHIELD 10710 WEST MARGINAL WAYS RRH TUKWILA, WA98168 KING COUNTY N ISSUED FOR: • ® io N CONSTRUCTION t � [ TOP REV:=DATE:=ISSUED FOR: BY:� N 6 ISO VIEW MANUFACTURER: ALCATEL-LUCENT MODEL: 9442 RRH 700MHz HEIGHT: 28.8" Qp 08-31-11 CONSTRUCTION JRS Qq 06-30-11 CLIENT REVIEW AJB WIDTH: 12.6" DRAWN BY:=CHK.: APV.: DEPTH: 5.7" WEIGHT: 44 LBS AJB BMH MWO CURRENT ISSUE DATE: 700MHz RRH 5 IF- 08-31-11 22x34 SCALE: 1" = 1'-0" 11x17 SCALE: 1/2" = 1'-0" IF LICENSURE: 12" 6" ��4 of Wasy�s2 O o,� s� s rn DRAWING INFORMATION: DO NOT SCALE DRAWINGS. CONTRACTOR MUST VERIFY ALL DIMENSIONS AND ADVISE CONSULTANTS OF ANY ERRORS AND OMISSIONS. ALL PREVIOUS ISSUES OF THIS DRAWING ARE SUPERSEDED BY THE LATEST REVISION. THE INFORMATION CONTAINED IN THIS SET OF DOCUMENTS IS PROPRIETARY BY NATURE. ANY USE OR DISCLOSURE OTHER THAN WHICH IS RELATED TO NAMED CLIENT IS STRICTLY PROHIBITED. DRAWING TITLE: F_ DETAIL SHEET FRONT VIEW SIDE VIEW BACK VIEW DRAWING NUMBER: �,0 /V�j_/ l J POWERWAVE MODEL: ZDhTOP ' VIEW ' P65-17-XLH-RR /fj _/'1 0 H ANTENNA DETAIL (SECTOR X & Z) 1 CEI JOB NUMBER: 11-69043 : 22x34 SCALE: 1/2" = 1'-0" 11x17 SCALE: 1/4" = 1'-0" Aw RRH & DIPLEXER MOUNTING DETAIL 22x34 SCALE: 3/4"=1'-0" 11x17 SCALE: 3/8"=V-0" LTE 9412 BACKPACK MOUNTED TO UNISTRUT PER MANUFACTURER 1 5/8"x1 5/8" S.S. UNISTRUT U-BOLTED TO 3"0 PIPE, TYP 0 RAYCAP SURGE SUPPRESSOR 6 p ENCLOSURE 6 EXCESS FIBER CABLE o ENCLOSURE r 5 N EXISTING GRADE 1 G. o b1 _ t3KIUUM 6'-0" COAX TO DIPLEXERS (TYP) 2100MHz RRH (TYP OF 3) MOUNTED TO UNISTRUT 4 PER MANUFACTURER A3 700MHz RRH (TYP OF 3) MOUNTED TO UNISTRUT 5 PER MANUFACTURER A-3 DIPLEXER MOUNTED ON UNISTRUT (TYP OF 6) 6 9A-3 PROPOSED 6x6 CABLE GUTTER MOUNTED ON UNISTRUT NEMA TYPE 3 BOX (TYP OF 2) 1 5l8"x1 5/8" SS UNISTRUT U-BOLTED TO 3"0 PIPE, TYP PIPE FLANGE 11 LTE 9412 BACKPACK MOUNTED TO UNISTRUT PER MANUFACTURER 11 EXCESS FIBER CABLE ENCLOSURE RAYCAP SURGE SUPPRESSOR ENCLOSURE 1 5l8"x1 518" S.S. UNISTRUT U-BOLTED TO 3"0 PIPE, TYP EXISTING GRADE f — I:' FIBER-1 RUNK CABLE TO TOWER 1'-0"0 24V DC POWER TRUNK (TYP) CABLE TO TOWER FIBER TRUNK CABLE 24V DC POWER TRUNK CABLE 2 1/2"0 - 3"0 ST[ 0 0 0- 0 0 1.0 CONCF CONCRETE PIER DETAIL 10 RET DETAIL 9 2204 SCALE: 1" = 1'-0" 111x17 SCALE: 1/2" = 1'-0" 22x34 SCALE: 6" = V-0" 11x17 SCALE: 3" = 1'-0" MOUNTING OPTIONS PER MANUFACTURER: WALL, H-BRACKET OR PIPE UP TO 3.5" O.D. —� V-5 1/4" MANUFACTURER:RAYCAP MODEL: DC6-48-60-0-lE SURGE SUPPRESSOR ENCLOSURE SURGE SUPPRESSOR ENCLOSURE ( 6 22x34 SCALE: 1 1/2" = 1'-0"1 11x17 SCALE: 3/4" = T-O" 3 1/2" FLUSH MOUNT STEEL PIPE FLANGE 3 112"0 O.D. GALVANIZED PIPE TOP OF CONCRETE (4) 3/8" HILTI-HAS EXP. ANCHORS W/ 4" MIN EMBED ELEVATION VIEW 3 1/2" FLUSH MOUNT STEEL PIPE FLANGE PLAN VIEW RRH H-FRAME DETAIL 3 I PIPE FLANGE DETAIL 22x34 SCALE: 314" = V-0" 111x17 SCALE: 3/8" = V-0" 12204 SCALE. 3 = V-0" 11x CABLE TO ENTER ANY OF THE (4) SIDES AND EXIT ANY OF THE (3) REMAINING SIDES — COVER NOT SHOWN FOR CLARITY — MANUFACTURER:ROSENBERGER u/ I MODEL: FB-15-ABOX CEO 10505 U EXCESS FIBER CABLE ENCLOSURE DIMENSIONS: 18"W X 18"H X 4"D CAPACITY: 35m (115t) OF 10MM CABLE EXCESS CABLE ENCLOSURE 22x34 SCALE: 1 1/2" = 1'-0" 11x17 SCALE: 3/4" = V-0" MANUFACTURER: ALCATEL-LUCENT MODEL: LTE 9412 eNodeB COMPACT ENCLOSURE HEIGHT: 31" WIDTH: 20" DEPTH: 24" WEIGHT: 143 LBS TOP 3 1/2"0 O.D. I o GALVANIZED PIPE 0 FRONT SIDE (DOOR OPEN) 00) 2 LTE 9412 eNodeB BACKPACK 1 1/2" = 1'-0" 1 22x34 SCALE: 3/4" = V-0" 111x17 SCALE: 3/8" = V-0" 5 1 6 at&t Your world. Delivered. GoodmanNetworks PLANS PREPARED BY: EC00 NEFts TONE 16928 WOODINVILLE-REDMOND RD NE, SUITE 210 WOODINVILLE. WA 98072 PHONE: 425.487.1732 FAX: 425,487.1734 EMAIL: cei@comerston ngr.wm W W W.CORNERSTONE-ENGR.COM PROJECT INFO: L ISSUED FOR: CCONSTRUCTION REV.= DATE: =ISSUED FOR: BY: —DRAWN BY: =CHK.: APV.: [CURRENT BMH MWO [CURRENT ISSUE DATE: 08-31-11 LICENSURE: Qp 08-31-11 CONSTRUCTION JRS Q06-30-11 CLIENT REVIEW AJB 'DRAWING INFORMATION: DO NOT SCALE DRAWINGS. CONTRACTOR MUST VERIFY ALL DIMENSIONS AND ADVISE CONSULTANTS OF ANY ERRORS AND OMISSIONS. ALL PREVIOUS ISSUES OF THIS DRAWING ARE SUPERSEDED BY THE LATEST REVISION. THE INFORMATION CONTAINED IN THIS SET OF DOCUMENTS IS PROPRIETARY BY NATURE. ANY USE OR DISCLOSURE OTHER THAN WHICH IS RELATED TO NAMED CLIENT IS STRICTLY PROHIBITED. DETAIL SHEET (DRAWING NUMBER: A-3.1 0 CEI JOB NUMBER: 11-69043 APPURTENANCES ITEM NEW EXISTING REMAIN REPLACE TOTAL ANTENNA 3 6 6 0 9 TMA 0 6 6 0 6 RET 6 12 12 0 18 700MHz RRH 3 0 0 0 3 2100MHz RRH 3 0 0 t 0 3 SCHEDULES 1x17 RF DATA SHEET SECTOR OTY ANTENNA RAD CENTER AZIMUTH ANTENNA LTE X 1 81'-6" AGL 170" SEE DETAIL 1/A-3 LTE Y 1 81'-6" AGL 280" SEE DETAIL 2/A-3 LTE Z 1 81'-5" AGL 45" SEE DETAIL 1/A-3 PROPOSED ANTENNA PLAN 1 2 TRUNK CABLES TYPE OF CABLE LENGTH PLACEMENT POWER 50'-0" BURIED FIBER 15'-0" BURIED COAX 100'-0" TOWER LEG 4 1 �J EXISTING ANTENNA PLAN I 1 1/2" = 1'-0" 111x17 SCALE: 1/4" = 1'-0" 40at&t Your world. Delivered. GoodmanNetworks PLANS PREPARED BY: CCO=r_n5TONE -� NOINEENINO. INC. 16928 WOODINVILLE-REDMOND RD NE, SUITE 210 WOODINVILLE, WA 98072 PHONE: 425.487.1732 FAX: 425.487.1734 EMAIL: cei@cornerstone�ngccom W W W,CORNERSTONE-ENGR.COM r PROJECT INFO: L ISSUED FOR: ILV:CONSTRUCTION =DATE:=ISSUED FOR. BY. 0 08 DRAWN BY: =CHK.: APV.: AJB I BMH MWO [CURRENT ISSUE DATE: 08-31-11 LICENSURE: -31-11 CONSTRUCTION JRS A06-30-11 CLIENT REVIEW AJB p�K W. OAS is OF phi o z po R 322 0 F �tsT� SS'GNAL 'DRAWING INFORMATION: DO NOT SCALE DRAWINGS. CONTRACTOR MUST VERIFY ALL DIMENSIONS AND ADVISE CONSULTANTS OF ANY ERRORS AND OMISSIONS. ALL PREVIOUS ISSUES Of THIS DRAWING ARE SUPERSEDED BY THE LATEST REVISION. THE INFORMATION CONTAINED IN THIS SET OF DOCUMENTS Is PROPRIETARY BY NATURE. ANY USE OR DISCLOSURE OTHER THAN WHICH IS RELATED 70 NAMED CLIENT IS STRICTLY PROHIBITED. DRAWING TITLE: EXISTING 81 PROPOSED ANTENNA PLANS 'DRAWING NUMBER: RF-1 0 CEI JOB NUMBER: 11-69043 1x17 SCALE: JROUNDING KEYED NOTES I I / I 1 NOTE: ALL GROUNDING WIRE RUNS AND CONNECTIONS, BOTH ABOVE AND BELOW GRADE, SHALL BE LOCATED INSIDE OF THE LEASE AREA LINE. SCHEMATIC GROUNDING PLAN PLAN NORTH SYMBOL DESCRIPTION O GROUND INSPECTION WELL ® COPPER GROUND ROD ® COMPRESSION LUG ® CADWELD CONNECTION `® SIDE SPLICE CADWELD - --- ----�- \/��j, FIELD VERIFY & TIE INTO EXISTING GROUNDING SYSTEM O(E) GROUND BUSS BAR, TYP. O(E) MAIN GROUND CONNECTION POINT. (V.I.F.) O(E) ANTENNA MOUNT STRUCTURE. OPROPOSED #2 STRANDED GREEN INSULATED GROUNDING WIRE, TYP. O(E) #2 STRANDED GREEN INSULATED COPPER GROUND LEAD, TYP. (V.I.F.) OPROPOSED GROUND CONNECTION TO ANTENNA. SEE 2/E-2. GROUNDING NOTES & LEGEND GENERAL GROUNDING NOTES 1. ALL DETAILS ARE SHOWN IN GENERAL TERMS. ACTUAL INSTALLATION AND CONSTRUCTION MAY VARY DUE TO SITE SPECIFIC CONDITIONS. 2. GROUND ALL ANTENNA BASES, FRAMES, CABLE RUNS, AND OTHER METALLIC COMPONENTS USING GROUND WIRES AND CONNECT TO SURFACE MOUNTED BUSS BARS. FOLLOW ANTENNA AND BTS MANUFACTURERS PRACTICES FOR GROUNDING REQUIREMENTS. GROUND COAX SHIELD AT BOTH ENDS AND EXIT FROM TOWER OR POLE USING MFR'S PRACTICES. 3. ALL GROUND CONNECTIONS SHALL BE CADWELD. ALL WIRES SHALL BE COPPER THHN/THWN. ALL GROUND WIRE SHALL BE GREEN INSULATED WIRE ABOVE GROUND. 4. CONTRACTOR TO VERIFY AND TEST GROUND TO SOURCE. GROUNDING AND OTHER OPERATIONAL TESTING WILL BE WITNESSED BY AT&T WIRELESS, LLC. REPRESENTATIVE. 5. REFER TO DIVISION 16 GENERAL ELECTRIC; GENERAL ELECTRICAL PROVISION AND COMPLY WITH ALL REQUIREMENTS OF GROUNDING STANDARDS. 6. ELECTRICAL CONTRACTOR TO PROVIDE DETAILED DESIGN OF GROUNDING SYSTEM, AND RECEIVE APPROVAL OF DESIGN BY AUTHORIZED AT&T WIRELESS, LLC. REPRESENTATIVE, PRIOR TO INSTALLATION OF GROUNDING SYSTEM. PHOTO DOCUMENT ALL CADWELDS AND GROUND RING 7. NOTIFY CONSTRUCTION MANAGER IF THERE ARE ANY DIFFICULTIES INSTALLING GROUNDING SYSTEM DUE TO SITE SOIL CONDITIONS. GROUNDING ROD NOTES (WHERE APPLICABLE) ELECTRICAL CONTRACTOR SHALL ORDER GROUND RESISTANCE TESTING ONCE THE GROUND SYSTEM HAS BEEN INSTALLED; A QUALIFIED INDIVIDUAL, UTILIZING THE FALL OF POTENTIAL METHOD, SHOULD PERFORM THE TEST. THE REPORT WILL SHOW THE LOCATION OF THE TEST AND CONTAIN NO LESS THAN 9 TEST POINTS ALONG THE TESTING LINE, GRAPHED OUT TO SHOW THE PLATEAU. 2 POINT GROUND TEST OR 3 POINT 62% TESTS WILL NOT BE ACCEPTED AS ALTERNATIVES TO THE AFORE MENTIONED GROUND TESTS. TEST SHALL BE PERFORMED WHILE THE COUNTERPOISE IS ISOLATED FROM THE A/C SYSTEM GRIDS AND EXISTING COMMUNICATIONS FACILITY. (OIL -woo? at&t Your world. Delivered. IQ­­­­.... ­11- j GoodmanNetworks PLANS PREPARED BY: —E CORNERS TONE 16928 WOODINVILLE-REDMOND RD NE, SUITE 210 WOODINVILLE, WA 98072 PHONE: 425.487.1732 FAX 425.487.1734 EMAIL: cei@cornem(ome ngccom W W W.CORNERSTONE-ENGR.COM r PROJECT INFO: L ISSUED FOR: CCONSTRUCTION REV.= DATE: -ISSUED FOR: Qp 08-31-11 CONSTRUCTION JRS Qq 06-30-11 CLIENT REVIEW AJB :DRAWN BY:=CHK.: APV.: AJB I BMH I MWO [CURRENT ISSUE DATE: 08-31-11 r- LICENSURE: `DRAWING INFORMATION: DO NOT SCALE DRAWINGS. CONTRACTOR MUST VERIFY ALL DIMENSIONS AND ADVISE CONSULTANTS OFANY ERRORS AND OMISSIONS. ALL PREVIOUS ISSUES OF THIS DRAWING ARE SUPERSEDED BY THE LATEST REVISION. THE INFORMATION CONTAINED IN THIS SET OF DOCUMENTS IS PROPRIETARY BY NATURE, ANY USE OR DISCLOSURE OTHER THAN WHICH IS RELATED TO NAMED CLIENT IS STRICTLY PROHIBITED. DRAWING TITLE: SCHEMATIC GROUNDING PLAN DRAWING NUMBER: E-1 0 CEI JOB NUMBER: 11-69043 ANTENNA — WEATHER SEAL T JUMPER DIN MALES GROUNDING KIT #2 GREEN FROM TOP GROUND BAR TO BOTTOM GROUND BA (E) (2) #2 SOLID BARE TINNED COPPER GROUNDING LEADS, CADWELD (TYP) (E) GROUNDING BUSS BAR & ATTACHMENT KIT W/ ISOLATORS BOLTED TO TOWER REFER TO SCHEDULE ON SHEET RF-1 FOR COAX CABLE APPROXIMATE LENGTH & PLACEMENT INSTALL GROUNDING KIT ABOVE COAX BEND (E) GROUNDING BUSS BAR & ATTACHMENT KIT W/ ISOLATORS BOLTED TO TOWER PROPOSED RRH & DIPLEXER H-FRAME (E) #2 SOLID BARE TINNED COPPER GROUND RING NOTE: • ALL CONNECTIONS TO BE CADWELDED • USE MECHANICAL CONNECTIONS ONLY WITH THE WRITTEN APPROVAL OF THE CONSTRUCTION MANAGER • HOISTING GRIP TO BE INSTALLED BELOW TOP GROUND KIT COAX GROUNDING KIT JUMPER CABLE GROUND BAR ATTACHED TO ICE BRIDGE SUPPORT (E) ARGUS POWER CABINET (E) NOKIA CABINET (E) UMTS CABINET (E) #2 SOLID BARE TINNED COPPER GROUNDING LEADS (TYP) (E) ARGUS TE43 CABINET PROPOSEDLTE 9412 BACK PACK PROPOSED AT&TH-FRAME 0 PROPOSED EXCESS CABLE ENCLOSURE PROPOSED SURGE SUPPRESSOR ENCLOSURE GROUNDING SCHEMATIC 6 NOT USED IL 5 22x34 SCALE NTS 111x17 SCALE NTS 22x34 SCALE: NTS 111x17 SCALE: NTS r i IIIIIIIIIII!I'dnIlllfilplpllpl V "I' �� °VIII ` �••�•TYPE GL LUG TYPE GR z NOTE: CADWELD "TYPES" SHOWN ABOVE ARE EXAMPLES — CONSULT WITH PROJECT MANAGER FOR SPECIFIC TYPES OF CADWELDS TO BE USED FOR THIS PROJECT. EQUIPMENT CHASSIS / GROUNDING BUSS BAR / CABLE RACEWAY NO -LUX ANTI —OXIDIZING COMPOUND (2) 3/8"0 SS HEXNUT (#2) TWO HOLE COMPRESSION LUG GROUND WIRE STUD (TYP OF 2 @ FRONT AND BACK OF CABINET) CLEAR HEAT SHRINK ON COMPRESSION LUGS 3/8"0 STAR / I } #2 STRANDED GREEN WASHER J)tt 1 INSULATED COPPER GROUND LEAD TO BUSS BAR OR #2 SOLID BARE TINNED PLAN COPPER TO GROUND RING NOTE: FOR GROUNDING CONNECTIONS TO PAINTED CABINETS CHASSIS, GRIND OFF ALL ENAMEL COATINGS TO BARE METAL AT LUG CONTACT AREA PRIOR TO MAKING BOLTED LUG CONNECTION. APPLY NO —LUX TO ALL EXPOSED BARE METAL. NOT USED 4 CADWELD DETAILS 3 [t22 YLUG CONNECTION 22x34 SCALE: NTS 11x17 SCALE: NTS 22x34 SCALE: NTS 11x17 SCALE: NTS x34 SCALE: NTS 1171 2 NOT USED 2204 SCALE: NTS 11x17 SCALE: NTS 1 6�at&t Your world. Delivered. PROJECT CONSULTANTS: QGoodmanNetworks PLANS PREPARED BY: -E E ORNEFi3 TONE 16928 WOODINVILLE-REDMOND RD NE, SUITE 210 WOODINVILLE, WA 98072 PHONE: 425.487.1732 FAX: 425.487.1734 EMAIL: cei@cor erstone Wr.com W W W.CORNERSTONE-ENGR.COM r PROJECT INFO: ISSUED FOR: CCONSTRUCTION =REV:=DATE:=ISSUED FOR: BY:� Qp 08-31-11 CONSTRUCTION JRS Qq 06-30-11 CLIENT REVIEW AJB LDRAWN BY: =CHK.: APV.: AJB BMH MWO [CURRENT ISSUE DATE: [08-31-11 LICENSURE: DRAWING INFORMATION: DO NOT SCALE DRAWINGS. CONTRACTOR MUST VERIFY ALL DIMENSIONS AND ADVISE CONSULTANTS OF ANY ERRORS AND OMISSIONS. ALL PREVIOUS ISSUES OF THIS DRAWING ARE SUPERSEDED BY THE LATEST REVISION. THE INFORMATION CONTAINED IN THIS SET OF DOCUMENTS IS PROPRIETARY BY NATURE. ANY USE OR DISCLOSURE OTHER THAN WHICH IS RELATED TO NAMED CLIENT IS STRICTLY PROHIBITED. DRAWING TITLE: GROUNDING DETAILS DRAWING NUMBER: E-2 0 CEI JOB NUMBER: 11-69043