Loading...
HomeMy WebLinkAboutPermit D16-0048 - TERRA STAFFING GROUP - TENANT IMPROVEMENTTERRA STAFFING 16400 SOUTHCENTER PKWY SUITE 200 D16-0048 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-438-9350 Web site: http://www.TukwilaWA.Rov Parcel No: 2623049021 Address: DEVELOPMENT PERMIT 16400 SOUTHCENTER PKWY 200 Project Name: TERRA STAFFING GROUP Permit Number: D16-0048 Issue Date: 3/10/2016 Permit Expires On: 9/6/2016 Owner: Name: Address: Contact Person: Name: Address: Contractor: Name: Address: License No: Lender: Name: Address: LEGACY PARTNERS COMMERCIAL PO BOX 130639 , CARLSBAD, WA, 92013 LINDA DUCEY Phone: (206) 441-1449 1500 WESTLAKE AVE N, SUITE 1, SEATTLE, WA, 98109 DP INC GENERAL CONTRACTORS Phone: (206) 361-2989 19909 BALLINGER WAY NE , LAKE FOREST PARK, WA, 98155 DPINCGC066BU Expiration Date: JOHN C RADOVICH DEV CO 2835 82ND AV SE #S-1, MERCER ISLAND, WA, 98040 DESCRIPTION OF WORK: INTERIOR TENANT IMPROVEMENTS TO AN EXISTING OFFICE SUITE ON THE SECOND FLOOR, SUITE 200, FOR OFFICE USE TO INCLUDE DEMOLITION OF CASEWORK AND PARTITIONS, NEW CONSTRUCTIION OF PARTIOTN AND DOORS, NEW CASEWORK AND A FEW EXISTING LIGHTING RELOCATED. NO STRUCTURAL WORK AND NO ALTERATIONS TO THE BUILDING CORE. Project Valuation: $70,000.00 Type of Fire Protection: Sprinklers: YES Fire Alarm: YES Type of Construction: IIA Fees Collected: $2,036.42 Occupancy per IBC: B Electrical Service Provided by: TUKWILA FIRE SERVICE Water District: TUKWILA Sewer District: TUKWILA SEWER SERVICE Current Codes adopted by the City of Tukwila: International Building Code Edition: International Residential Code Edition: International Mechanical Code Edition: Uniform Plumbing Code Edition: International Fuel Gas Code: 2012 2012 2012 2012 2012 National Electrical Code: WA Cities Electrical Code: WAC 296-46B: WA State Energy Code: 2014 2014 2014 2012 Public Works Activities: Channelization/Striping: Curb Cut/Access/Sidewalk: Fire Loop Hydrant: Flood Control Zone: Hauling/Oversize Load: Land Altering: Landscape Irrigation: Sanitary Side Sewer: Sewer Main Extension: Storm Drainage: Street Use: Water Main Extension: Water Meter: Volumes: Cut: 0 Fill: 0 Number: 0 No Permit Center Authorized Signature: (,,&J,kQJ_.r Date: I hearby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this development permit and agree to the conditio..: tached to this permit. Signature: Print Name: Date: ✓ f r f 2 O1. This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: ***BUILDING PERMIT CONDITIONS*** 2: Work shall be installed in accordance with the approved construction documents, and any changes made during construction that are not in accordance with the approved construction documents shall be resubmitted for approval. 3: All permits, inspection record card and approved construction documents shall be kept at the site of work and shall be open to inspection by the Building Inspector until final inspection approval is granted. 4: New suspended ceiling grid and light fixture installations shall meet the seismic design requirements for nonstructural components. ASCE 7, Chapter 13. 5: Partition walls shall not be tied to a suspended ceiling grid. All partitions greater than 6 feet in height shall be laterially braced to the building structure. Such bracing shall be independent of any ceiling splay bracing. 6: All construction shall be done in conformance with the Washington State Building Code and the Washington State Energy Code. 7: There shall be no occupancy of a building until final inspection has been completed and approved by Tukwila building inspector. No exception. 8: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of this requirement. 9: Every occupied space other than enclosed parking garages and buildings used for repair of automobiles shall be ventilated in accordance with the applicable provisions of the International Mechanical Code. 10: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206-431-3670). 11: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center. 12: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 13: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431-3670). 17: The total number of fire extinguishers required for a light hazard occupancy with Class A fire hazards is calculated at one extinguisher for each 3,000 sq. ft. of area. The extinguisher(s) should be of the "all purpose" (2A, 10 B:C) dry chemical type. The travel distance to any extinguisher must be 75' or less. (IFC 906.3) (NFPA 10, 5.4) 14: Portable fire extinguishers, not housed in cabinets, shall be installed on the hangers or brackets supplied. Hangers or brackets shall be securely anchored to the mounting surface in accordance with the manufacturer's installation instructions. Portable fire extinguishers having a gross weight not exceeding 40 pounds (18 kg) shall be installed so that its top is not more than 5 feet (1524 mm) above the floor. Hand- held portable fire extinguishers having a gross weight exceeding 40 pounds (18 kg) shall be installed so that its top is not more than 3.5 feet (1067 mm) above the floor. The clearance between the floor and the bottom of the installed hand-held extinguishers shall not be less than 4 inches (102 mm). (IFC 906.7 and IFC 906.9) 15: Extinguishers shall be located in conspicuous locations where they will be readily accessible and immediately available for use. These locations shall be along normal paths of travel, unless the fire code official determines that the hazard posed indicates the need for placement away from normal paths of travel. (IFC 906.5) 16: Fire extinguishers require monthly and yearly inspections. They must have a tag or label securely attached that indicates the month and year that the inspection was performed and shall identify the company or person performing the service. Every six years stored pressure extinguishers shall be emptied and subjected to the applicable recharge procedures. If the required monthly and yearly inspections of the fire extinguisher(s) are not accomplished or the inspection tag is not completed, a reputable fire extinguisher service company will be required to conduct these required surveys. (NFPA 10, 7.2, 7.3) 18: Maintain fire extinguisher coverage throughout. 19: Egress doors shall be readily openable from the egress side without the use of a key or special knowledge or effort. (IFC 1008.1.8.3 subsection 2.2) 20: Dead bolts are not allowed on auxiliary exit doors unless the dead bolt is automatically retracted when the door handle is engaged from inside the tenant space. (IFC Chapter 10) 21: Exit hardware and marking shall meet the requirements of the International Fire Code. (IFC Chapter 10) 22: Door handles, pulls, latches, locks and other operating devices on doors required to be accessible by Chapter 11 of the International Building Code shall not require tight grasping, tight pinching or twisting of the wrist to operate. (IFC 1008.1.9.1) 23: Aisles and aisle access ways serving as a portion of the exit access in the means of egress system shall comply with the requirements of this section. Aisles or aisle access ways shall be provided from all occupied portions of the exit access which contain seats, tables, furnishings, displays and similar fixtures or equipment. The required width of aisles shall be unobstructed. (IFC 1017.1) 27: Fire protection systems shall be maintained in accordance with the original installation standards for that system. Required systems shall be extended, altered or augmented as necessary to maintain and continue protection whenever the building is altered, remodeled or added to. Alterations to fire protection systems shall be done in accordance with applicable standards. (IFC 901.4) 25: Sprinklers shall be installed under fixed obstructions over 4 feet (1.2 m) wide. (NFPA 13-8.6.5.3.3) 24: All new sprinkler systems and all modifications to existing sprinkler systems shall have fire department review and approval of drawings prior to installation or modification. New sprinkler systems and all modifications to sprinkler systems involving more than 50 heads shall have the written approval of Factory Mutual or any fire protection engineer licensed by the State of Washington and approved by the Fire Marshal prior to submittal to the Tukwila Fire Prevention Bureau. No sprinkler work shall commence without approved drawings. (City Ordinance No. 2436). 28: A fire alarm system is required for this project. The fire alarm system shall meet the requirements of N.F.P.A. 72 and City Ordinance #2437. 29: All new fire alarm systems or modifications to existing systems shall have the written approval of The Tukwila Fire Prevention Bureau. No work shall commence until a fire department permit has been obtained. (City Ordinance #2437) (IFC 901.2) 30: Maintain fire alarm system audible/visual notification. Addition/relocation of walls or partitions may require relocation and/or addition of audible/visual notification devices. (City Ordinance #2437) 31: An electrical permit from the City of Tukwila Building Department Permit Center (206-431-3670) is required for this project. 32: All electrical work and equipment shall conform strictly to the standards of the National Electrical Code. (NFPA 70) 33: The maximum flame spread class of finish materials used on interior walls and ceilings shall not exceed that set forth in Table No. 803.9 of the International Building Code. 34: In order to provide you with the fastest police and fire protection under emergency conditions, please post your suite, room or apartment number in a conspicuous place near the main entry door. 26: Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (City Ordinances #2436 and #2437) 35: Any overlooked hazardous condition and/or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. 36: These plans were reviewed by Inspector 511. If you have any questions, please call Tukwila Fire Prevention Bureau at (206)575-4407. PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 1700 BUILDING FINAL** 1400 FIRE FINAL 0409 FRAMING 0606 GLAZING 0406 SUSPENDED CEILING CITY OF TUKW, 1 Community Development Department Public Works Department Permit Center 6300 Southcenter Blvd, Suite 100 Tukwila, WA 98188 http://www.Tukwi IaWA.gov Building Permit No. 1)( oig Project No. Date Application Accepted: Date Application Expires: 5,-)-1--d, 40, (For office use only) CONSTRUCTION PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **Please Print** SITE LOCATION Site Address: 16400 Southcenter Parkway Tenant Name: Terra Staffing Group PROPERTY OWNER Name: John C. Radovich Development Co. Address: 2385 82nd Ave. SE, suite 300 City: Mercer Island State: WA Zip: 98040 CONTACT PERSON — person receiving all project communication Name: Linda Ducey Address: 1500 Westlake Ave. N. , suite one City: Seattle state: WA zip: 98109 Phone: (206) 441-1449 Fax: Email: 1.ducey@marvinstein.com GENERAL CONTRACTOR INFORMATION Company Name: DP Inc - General Contrators Address: 19936 Ballinger Way NE City: Seattle State: WA Zip: 98155 Phone: (206) 361-2989 Fax: Contr Reg No.: DPINCGC066BU Exp Date: 01/31/2018 Tukwila Business License No.: H:Wpplications\Forms-Applications On Line\2011 Applicationstpermit Application Revised - 8-9-11.docx Revised: August 2011 bh King Co Assessor's Tax No.: 262304-9021 Suite Number: 200 Floor: 2nd floor New Tenant: m Yes ..No ARCHITECT OF RECORD Company Name: Marvin Stein Associates Architect Name: Mark Evans Address: 1500 Westlake Ave. N. , suite one City: Seattle State: WA zip: 98109 Phone: (206) 441-1449 Fax: Email: m.evans@marvinstein.com ENGINEER OF RECORD Name:\ I /�- k [6; Id_ Company Name: 1 J kik ..5E City:h9rtn ( Engineer Name: Stat : (i i4 Zip: MT Address: City: State: Zip: Phone: Fax: Email: LENDER/BOND ISSUED (required for projects $5,000 or greater per RCW 19.27.095) Name:\ I /�- k [6; Id_ Address:.x56 1 J kik ..5E City:h9rtn ( ` i Stat : (i i4 Zip: MT soy N. Page 1 of 4 BUILDING PERMIT INFORMATIOP D6-431-3670 Valuation of Project (contractor's bid price): $ 70,000 Describe the scope of work (please provide detailed information): Interior tenant improvements to any existing office suite on the second floor, suite #200, for office use to include demolition of casework and partitions, new construction of partitions and doors, new casework, and a few existing lighting relocated. No structural work and no alterations to the building core. Existing Building Valuation: $ Will there be new rack storage? ❑ Yes m.. No If yes, a separate permit and plan submittal will be required. Provide All Building Areas in Square Footage Below PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): 84,975 Floor area of principal dwelling: 64,725 Floor area of accessory dwelling: 0 *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact: Handicap: Will there be a change in use? 0 Yes 0 No If "yes", explain: FIRE PROTECTION/HAZARDDOUS MATERIALS: Sprinklers Jij Automatic Fire Alarm 0 None 0 Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? 0 Yes No If `yes', attach list of materials and storage locations on a separate 8-1/2"x 11" paper including quantities and Material Sa ety Data Sheets. SEPTIC SYSTEM 0 On-site Septic System — For on-site septic system, provide 2 copies of a current septic design approved by King County Health Department. H:\Applications\Fortns-Applications On Line \2011 Applications\Pcrmit Application Revised - 8-9-11.docx Revised: August 2011 bh Page 2 of 4 Existing Interior Remodel Addition to Existing Structure New Type of Construction per IBC Type of Occupancy per IBC 1s Floor 0 2"d Floor 13,700 2,788 0 0 II -A sprinkler B- office 3`d Floor 0 Floors thru 0 Basement 0 Accessory Structure* 0 Attached Garage 0 Detached Garage 0 Attached Carport 0 Detached Carport 0 Covered Deck 0 Uncovered Deck 0 PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): 84,975 Floor area of principal dwelling: 64,725 Floor area of accessory dwelling: 0 *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact: Handicap: Will there be a change in use? 0 Yes 0 No If "yes", explain: FIRE PROTECTION/HAZARDDOUS MATERIALS: Sprinklers Jij Automatic Fire Alarm 0 None 0 Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? 0 Yes No If `yes', attach list of materials and storage locations on a separate 8-1/2"x 11" paper including quantities and Material Sa ety Data Sheets. SEPTIC SYSTEM 0 On-site Septic System — For on-site septic system, provide 2 copies of a current septic design approved by King County Health Department. H:\Applications\Fortns-Applications On Line \2011 Applications\Pcrmit Application Revised - 8-9-11.docx Revised: August 2011 bh Page 2 of 4 PERMIT APPLICATION NOTES — Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDIN Signature: Print Name' OR AUT O ' ZED ENT: ebecca P avidson Date: 02/19/2016 Day Telephone: (206) 267-6061 Mailing Address: 2385 82nd Ave. SE., suite 300 Mercer Island WA 98040 City State Zip H:\Applications\Forms-Applications On Line \2011 Applications\Permit Application Revised - 8-9-11.docx Revised: August 2011 bh Page 4 of 4 PUBLIC WORKS PERMIT INFO -ATION — 206-433-0179 Scope of Work (please provide detailed information): one existing sink replaced one existing dishwasher replaced Call before you Dig: 811 Please refer to Public Works Bulletin #1 for fees and estimate sheet. Water District ❑ ...Tukwila ❑ ...Water District #125 ❑ ...Water Availability Provided Sewer District ❑ ...Tukwila ❑ ...Sewer Use Certificate 0 .. Highline ❑ ... Valley View ❑ .. Renton ❑ ... Sewer Availability Provided 0 .. Renton ❑ .. Seattle Septic System: ❑ On-site Septic System — For on-site septic system, provide 2 copies of a current septic design approved by King County Health Department. Submitted with Application (mark boxes which apply): ❑ ...Civil Plans (Maximum Paper Size — 22" x 34") ❑ ...Technical Information Report (Storm Drainage) ❑ ...Bond 0 .. Insurance 0 .. Easement(s) Proposed Activities (mark boxes that apply): ❑ ...Right-of-way Use - Nonprofit for less than 72 hours ❑ ...Right-of-way Use - No Disturbance ❑ ...Construction/Excavation/Fill - Right-of-way 0 Non Right-of-way ❑ ...Total Cut cubic yards ❑ ...Total Fill cubic yards ❑ ...Sanitary Side Sewer ❑ ...Cap or Remove Utilities 0 ...Frontage Improvements ❑ ...Traffic Control ❑ ...Backflow Prevention - Fire Protection Irrigation ❑ . ❑. ❑ . ❑. ❑ .. Geotechnical Report ❑ .. Maintenance Agreement(s) ❑ ...Traffic Impact Analysis ❑ ...Hold Harmless — (SAO) ❑ ...Hold Harmless — (ROW) ❑ .. Right-of-way Use - Profit for less than 72 hours ❑ .. Right-of-way Use — Potential Disturbance ❑ .. Work in Flood Zone ❑ .. Storm Drainage . Abandon Septic Tank . Curb Cut . Pavement Cut . Looped Fire Line Domestic Water ❑ ...Permanent Water Meter Size... ❑ ...Temporary Water Meter Size .. ❑ ...Water Only Meter Size ❑ ...Sewer Main Extension Public ❑ ...Water Main Extension Public f> 91 11 WO # WO # WO # Private 0 Private 0 ❑ .. Grease Interceptor ❑ .. Channelization ❑ .. Trench Excavation ❑ .. Utility Undergrounding ❑ ...Deduct Water Meter Size ff FINANCE INFORMATION Fire Line Size at Property Line Number of Public Fire Hydrant(s) ❑ ...Water 0 ...Sewer 0 ...Sewage Treatment Monthly Service Billing to: Name: Day Telephone: Mailing Address: Water Meter Refund/Billing: Name: Mailing Address: City State Zip Day Telephone: City State Zip H:Wpplications\Forms-Applications On Line \2011 Applications\permit Application Revised - 8-9-11.docx Revised: August 2011 bh Page 3 of 4 Cash Register Receipt City of Tukwila DESCRIPTIONS 1 ACCOUNT I QUANTITY PermitTRAK I PAID $2,036.42 D16-0048 Address: 16400 SOUTHCENTER PKWY 200 Apn: 2623049021 $2,036.42 DEVELOPMENT $1,976.66 PERMIT FEE R000.322.100.00.00 0.00 $1,195.25 PLAN CHECK FEE R000.345.830.00.00 0.00 $776.91 WASHINGTON STATE SURCHARGE B640.237.114 0.00 $4.50 TECHNOLOGY FEE $59.76 TECHNOLOGY FEE TOTAL FEES PAID BY RECEIPT: R7741 R000.322.900.04.00 0.00 $59.76 $2,036.42 Date Paid: Monday, February 22, 2016 Paid By: RADOVICH PROPERTIES LLC Pay Method: CHECK 002247 Printed: Monday, February 22, 2016 1:48 PM 1 of 1 CRWSYSTEMS INSPECTION O. INSPECTION RECORD Retain a copy with permit b/(-oo90 PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-367 Permit Inspection Request Line (206) 438-9350 kt Project: -nretzA o-Arp ay Type of Inspection: .c%L Address:. /Gyoc Sevnit6urEc Pay Date Called: Special Instructions: Date Wanted/ /9J,6 / Requester: 70Ny Phone No: qi/- Sqi- 672Z Approved per applicable codes. L! Corrections required prior to approval. COMMENTS: (1/42i/JG- Inspector: / Date: 7 REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd„ Suite 100. Call to schedule reinspection. INSPECTION NO. INSPECTION RECORD Retain a copy with permit J�►6 -00q8 PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 Permit Inspection Request Line (206) 438-9350 (206) 431-3670 Project T e of Inspection: Address: i 00 .5')U774e,e0ree PYA -Y1 Date Called: Special Instructions: CA(d- Date Wanted:C-57-n3. 71/3-1/6 pail. Requester: Tey Phone No: L42.C- Sq/ —6?2Z ElApproved per applicable codes. L;i Corrections required prior to approval. COMMENTS: Peea 11'bi AP/Wife-A &m..br 6 PSA CALL- ---;(//1Cfie/17 Inspector: A1 Date: n REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. m! INSPECTION RECORD Retain a copy with permit PECTION NO D(°°tfo PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 Permit Inspection Request Line (206) 438-9350 (206) 431-3670 Project: Project: 'terra S Type o Inspection! , .Wt(vt• Address: I o ® i triCtir �° t Date Ca led: s4(�e4,2.061 Dateanted� � a.m. p.m. Speciaf �"l V �� Instructions:,{ yl r./0 v./ccII �I J Rqueste ica : /�e Phbne N : Aar 15-12, Approved per applicable codes. LJ Corrections required prior to approval. OM MENTS: P c eP t '/ re VigEf. CR I ca inspector: Date: —2L f,6 REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION NUMBER INSPECTION RECORD Retain a copy with permit �i6-c; (4 PERMIT NUMBERS CITY OF TUKWILA FIRE DEPARTMENT 206-575-4407 Project:/%' ''Irq --, 4('/r1 c Type of Inspection: Frre-- f : nit /al,. r,or Address: / G I7W Suite #: 77C) Soti) 4 c -e e r aut Contact Person: Special Instructions: Phone No.: Approved per applicable codes. Corrections required prior to approval. COMMENTS: !, 3 r -G. ,a 10 1 fl ' i -- (4A Needs Shift Inspection: '; PERMIT COORS COPY PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: D16-0048 DATE: 02/22/16 PROJECT NAME: TERRA STAFFING GROUP SITE ADDRESS: 16400 SOUTHCENTER PKWY - SUITE 200 X Original Plan Submittal Response to Correction Letter # Revision # before Permit Issued Revision # after Permit Issued DEPARTMENTS: A—s c L6)49—IP Building Division Rik jblic ask /vrk u tO \it tik '\ Fire PreventionIIIPlanning Division Structural n Permit Coordinator a of PRELIMINARY REVIEW: Not Applicable ❑ (no approval/review required) DATE: 02/23/16 Structural Review Required REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: DUE DATE: 03/22/16 Approved Corrections Required ❑ (corrections entered in Reviews) Approved with Conditions Denied (ie: Zoning Issues) n Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg 0 Fire 0 Ping 0 PW ❑ Staff Initials: 12/18/2013 D P INC GENERAL CONTRACTOR S Home Espanol Contact Safety & Health Claims & Insurance Washington State Department of Labor & Industries Page 1 of 2 Search L&I A -Z Index Help My 1,,&1 Workplace Rights Trades & Licensing D P INC GENERAL CONTRACTORS Owner or tradesperson Principals DODSON, WILLIAM, PRESIDENT Doing business as D P INC GENERAL CONTRACTORS WA UBI No. 601 515 833 19936 BALLINGER WAY NE SEATTLE, WA 98155 206-361.2989 KING County Business type Corporation License Verify the contractor's active registration / license / certification (depending on trade) and any past violations. Construction Contractor Active. Meets current requirements. License specialties GENERAL License no. DPINCGC066BU Effective — expiration 01/31/1994— 01/31/2018 Bond ................. Merchants Bonding Co (Mutual) Bond account no. WA28622 $12,000.00 Received by L&I Effective date 12/27/2012 01/31/2013 Expiration date Until Canceled Bond history Insurance ............................. Continental Western Ins Co Policy no. CWP6015605 $1,000,000.00 Received by L&I Effective date 08/13/2015 09/15/2014 Expiration date 09/15/2016 Insurance history Savings No savings accounts during the previous 6 year period. Lawsuits against the bond or savings No lawsuits against the bond or savings accounts during the previous 6 year period. L&I Tax debts No L&I tax debts are recorded for this contractor license during the previous 6 year period, but some debts may be recorded by other agencies. https://secure.lni.wa.gov/verify/Detail.aspx?UBI=601515833&LIC=DPINCGC066BU&SAW= 03/10/2016 01 0 1 U 01 0 01 0 N 01 0 c"n N C 0 0 ov �cf) N c� 0 I _Q 1 ocL. ACT ADJ AFF ALT ALUM APPROX BLDG BLKG BIS CAB CLR CLG CL COL COMM COMP CONST CONT CPT CT DIA DIM DR DW DWG EA ELEC ELEC'L ELEV EQ EXIST EXT FIN FLR FLUOR FMC FR FT FURN GA GALV GD GL GWB HC HDW HM HT HVAC IN INCL INSUL INT JT LL@TE LF ACOUSTICAL CEILING TILE ADJACENT / ADJUSTABLE ABOVE FINISH FLOOR ALTERNATE ALUMINUM APPROXIMATELY AT BUILDING BLOCKING BUILDING STANDARD CABINET CLEAR/CLEARANCE CEILING CENTERLINE COLUMN COMMUNICATION COMPOSITION CONSTRUCTION CONTINUOUS CARPET CERAMIC/CONCRETE TILE DIAMETER DIMENSION DOOR DISHWASHER DRAWING EXISTING / EAST EACH ELECTRIC ELECTRICAL ELEVATION (VIEW) EQUAL EXISTING EXTERIOR FINISH FLOOR FLUORESCENT FLOOR MATERIAL CHANGE FIRE RATED FEET FURNISH / FURNISHINGS GAUGE GALVANIZED GARBAGE DISPOSAL GLASS / GLAZING GYPSUM WALL BOARD HOLLOW CORE HARDWARE HOLLOW METAL HEIGHT HEATING, VENTILATING, AIR CONDITIONING INCH INCLUDE INSULATION INTERIOR JOINT BY LANDLORD AT TENANTS EXPENSE LINEAL FOOT ABBREVIATIONS MAX MECH MFR MIN MISC MSA MTD MTL MW N N/A NIC NO NOM NTS OC OPNG OPP ORIG PERM PL PLAM PLYWD PR PTN R RB REF REFL'D REINF REQ'D REV RM RO S SCHED SC SECT SIM SPEC SQ STD STL STOR SUSP TEL TSG TYP UNO VCT VERT W/ W/O WC WD MAXIMUM MECHANICAL MANUFACTURER MINIMUM MISCELLANEOUS MARVIN STEIN ASSOCIATES MOUNTED METAL MICROWAVE OVEN NORTH/NEW NOT APPLICABLE NOT IN CONTRACT NUMBER NOMINAL NOT TO SCALE ON CENTER OPENING OPPOSITE ORIGINAL PERMANENT PLATE PLASTIC LAMINATE PLYWOOD PAIR PARTITION RADIUS / REMOVE / RELOCATE RUBBER BASE REFRIGERATOR REFLECTED REINFORCING REQUIRED REVISION / REVERSE ROOM ROUGH OPENING SOUTH SCHEDULE SOLID CORE SECTION SIMILAR SPECIFICATION SQUARE STANDARD STEEL STORAGE SUSPENDED TELEPHONE TEMPERED SAFETY GLASS TYPICAL UNLESS NOTED OTHERWISE VINYL COMPOSITION TILE VERTICAL WEST WITH WITHOUT WALLCOVERING WOOD AEU NO CHANGE IN BUILDING AREA NO CORE / SHELL WORK NO STRUCTURAL WORK NO EXTERIOR WORK NO CHANGE IN USE AREA OF WORK ( 2,788 S F ) OCCUPANT LOAD: PER TABLE 1004.1.2: 100 SF PER OCCUPANT FOR "B" (OFFICE). NUMBER OF REQUIRED EXITS PER IBC 1015.1. 2788 SF @ 1:100 = 28 OCCUPANTS 1 EXIT(S) REQUIRED, 1 EXIT(S) PROVIDED VICINITY MAP TRAVEL DISTANCE: MAXIMUM LENGTH ALLOWED IS 300' PER IBC TABLE 1016.2. M STRANDER BLVD NTS POINT WHERE 2 PATHS TO SEPARATE EXITS ARE AVAILABLE. 238 I I I I I 36 36 COMMON PATH OF EGRESS TRAVEL: MAXIMUM LENGTH ALLOWED IS 100' PER IBC TABLE 1014.3. LONGEST COMMON PATH OF EGRESS TRAVEL = ± 88 FT. SOUTHCENTER PLACE EXISTING 5 -STORY OFFICE BUILDING EXISTING ELEVATOR LOBBY AND CORRIDOR - NIC., TYP. CORE (SHADED AREA) - N.I.C., TYP. NORTH NA 3 KEY PLAN, EXITING AND OCCUPANCY LOAD CALCULATION NTS 4 NA NA 9 NA NA 10 NA NA 11 131 NA NA 141 NA NA 151 NA NA 111111 111111 I I I I I /a SOUTHCENTER PLACE/ Ir Ir 279 \ 1111111111[1111111111 SITE MAP 4'-0" WIDE ACOUSTIC BATT INSULATION CENTERED OVER PARTITION ABOVE HUNG CEILING. 1/4" NON-COMBUSTABLE WOOD FILLER UNDER MAIN RUNNERS. CEILING @ + 81-6" A.F.F. (WHERE INDICATED ON REFLECTED CEILING PLAN). CONTINUOUS 'L' METAL TRIM W/ PAPER WING (BOTH SIDES OF PARTITION) OUTBACK STEAK HOUSE M NORTH SEISMIC BRACING (BEYOND) PER 16171-1. 1/8" BLACK FOAM TAPE, HOLD .•1 BACK 1/4" FROM EDGE OF TRACK (BOTH SIDES) ACOUSTIC BATT INSULATION . GALV. STEEL SILL TRACK. ATTACH TO STRUCTURE WITH HILTI X -U (OR XU15) UNIVERSAL KNURLED SHANK POWER DRIVEN FASTENER WITH MIN. 1" EMBEDMENT @ 16" O.C. (FOLLOW MANUFACTURER'S INSTRUCTIONS). FLOORING AS SCHEDULED (BOTH SIDES OF PARTITION) STUD SCHEDULE STUD SCHEDULE: 2-1/2" = 250S125-27 (22 GA); MAX 10'-0" HIGH. 3-5/8" = 362S125-27 (22 GA); MAX 13'-0" HIGH. 6" = 600S125-27 (22 GA); MAX 17'-6" HIGH. NOTES: 1. ALL STUDS ARE AT 16" O.C. 2. USE SAME GAUGE AS STUDS FOR TRACKS AND CHANNEL. 3. USE SSMA TECHNICAL GUIDES. ) ) ) ) ) METAL TRACK WITH (2) #10 SCREWS AT 16" O.C. REVEAL (PAINT BLACK) OR MATCH EXISTING CONDITION. (BOTH SIDES OF PARTITION) 5/8" FIRE RETARDANT TREATED PLYWOOD BLOCKING AT WALL HUNG ITEMS (WHERE APPLICABLE- REFER TO DRAWING PLANS). ALTERNATE FOR BLOCKING: 20" WIDE SHEET METAL AT +40" FROM FLOOR TO BOTTOM (IN LIEU OF WOOD BLOCKING) 5/8" GWB, TYPE 'X' EACH SIDE BASE, AS SCHEDULED. (BOTH SIDES OF PARTITION.) EXISTING STRUCTURE (BELOW) GALV STEEL STUD, PER STUD SCHEDULE, WITH 5/8" TYPE 'X' GWB EACH SIDE. NTS STANDARD TENANT SOUND PARTITION 1-1/2" =1'-0" EXISTING STRUCTURE METAL CLIP METAL STUDS STAGGERED @ 8'-0" O.C. FOR ALL UNBRACED STRAIGHT RUNS OF WALL OVER 12'-0". ATTACH TO STRUCTURE ABOVE. (2) #10 SCREWS SCHEDULED CEILING TILE & GRID 8' MAX 8' MAX 8' MAX 8' MAX 8' MAX 8' MAX .-2' MAX r y -1( y xkTO END I , OF WALL OMIT BRAC IN AT WALL C G LATERAL BRACING (STAGGERED) PER DETAIL ABOVE (TYP.) J.;111 LATERAL WALL BRACING PLAN VIEW NTS TOP OF WALL 16 NOTES: 1. LATERAL BRACING IS TO BE INSTALLED ON TENANT PARTITIONS AT 8 FEET O.C. EXCEPT AT INTERSECTIONS WITH WALLS AT LEAST 4 FEET LONG. (PER TYPICAL PARTITION PLAN) 2. PROVIDE BRACING AT ANY PERMANENT PARTITION THAT IS NOT ATTACHED TO CEILING GRID. STANDARD HEAD BRACING NA 12 17 SCOPE OF WORK TENANT IMPROVEMENT TO AN EXISTING SUITE ON THE 2ND FLOOR FOR OFFICE USE TO INCLUDE: • DEMOLITION OF CASEWORK AND PARTITIONS • CONSTRUCTION OF PARTITIONS AND DOORS • CONSTRUCTION OF CASEWORK • NEW PAINT AND FLOORING THROUGHOUT SUITE • INSTALLATION AND RELOCATION OF LIGHT FIXTURES • NO STRUCTURAL WORK • NO ALTERATIONS OF CORE. AREA OF SUITE: 2,788 SQ.FT. AREA OF FLOOR: ±13,700 SQ. FT. OCCUPANCY TYPE: B, OFFICE CONSTRUCTION TYPE: II -A, FULLY SPRINKLERED APPLICABLE CODES: 2012 INTERNATIONAL BUILDING CODE (IBC) 2012 INTERNATIONAL FIRE CODE (IFC) 2012 INTERNATIONAL MECHANICAL CODE (IMC) ICC/ANSI 117.1- ACCESSIBLE AND USABLE BUILDINGS AND FACILITIES 2012 WASHINGTON STATE ENERGY CODE (WSEC) 2012 INTERNATIONAL FUEL AND GAS CODE (IFGC) 2012 UNIFORM PLUMBING CODE (UPC) 2014 NATIONAL ELECTRICAL CODE (NEC) WASHINGTON INDOOR AIR QUALITY CODE ASSESSOR'S PARCEL #: 262304-9021 LEGAL DESCRIPTION PARCEL 1 OF CITY OF TUKWILA REVISED SHORT PLAT #77-51-55 AKA BLA #3-79 REC #7904180861 SD PLAT DAF - POR SE 1/4 OF NW 1/4 BEG AT MONUMENTAL INTSN OF C/L'S OF SOUTHCENTER PARKWAY 57TH AVE S & STRANDER BLVD S 164TH ST TH S 8-45-5 E 325.05 FT TH 0-25-58 E 30 FT TO AN INTSN WITH S MGN SD STRANDER BLVD & TPOB TH CONTG S 0-25-58 E 200 FT TH S 89-45-58 E 350 FT TH S 0-25-58 E 1093.20 FT TH N 89-43-19 W 626.31 FT TO E ALG ARC OF CURVE TO RGT RAD 50 FT THRU C/A 91-11-50 79.53 FT TO S MGN STRANDER BKVD TH S 89-45-58 E 237.72 FT TO TPOB LESS POR OF SD PAR.1 FOR ST UNDER REC NO 8310250922 LESS RD PER SUP COURT #09-2-19459-9 KNT PROJECT DIRECTORY TENANT TERRA STAFFING GROUP BUILDING REPRESENTATIVE JOHN C. RADOVICH DEVELOPMENT CO. 2385 82ND AVENUE SE, SUITE 300 MERCER ISLAND, WA 98040 CONTACT: REBECCA DAVIDSON TELEPHONE: (206) 267-6060 FAX: (206) 206-267-6061 EMAIL: REBECCADAVIDSON@JCRDEVCO.COM GENERAL NOTES 1. COMPLY WITH ALL APPLICABLE CODES. DESIGNER MARVIN STEIN ASSOCIATES, LLC 1500 WESTLAKE AVE. N, SUITE ONE SEATTLE, WASHINGTON 98109 CONTACT: LINDA DUCEY TELEPHONE: (206) 441-1449 EMAIL: L.DUCEY@marvinstein.com CONTRACTOR TBD 2. THE GENERAL CONTRACTOR SHALL VISIT THE JOB SITE AND VERIFY THE FIELD CONDITIONS PRIOR TO PURCHASING MATERIALS OR COMMENCING THE WORK. 3. REPORT ANY DISCREPANCIES BETWEEN ACTUAL FIELD CONDITIONS AND DRAWINGS TO MSA BEFORE PROCEEDING WITH THE WORK. 4. VERIFY THE BUILDING STANDARDS (BIS) BEFORE PROCEEDING WITH THE WORK. 5. OBTAIN ALL REQUIRED PERMITS AND APPROVALS BEFORE PROCEEDING WITH THE WORK. 6. WALLS, PARTITIONS AND CEILINGS SHALL BE INDEPENDENTLY BRACED TO RESIST SEISMIC FORCES. 7. PROVIDE BLOCKING AT ALL WALL MOUNTED ITEMS. 8. ALIGN AND SHIM TRANSITIONS BETWEEN OLD AND NEW CONDITIONS. 9. LEVEL THE FLOOR. DEVIATIONS OF ± 1/2" WITHIN 10'-0" IS THE ACCEPTABLE LIMIT. 10. GENERAL CONTRACTOR REVIEW AND STAMP OR MARK REQUIRED SUBMITTALS AND SHOP DRAWINGS PRIOR TO SENDING COPIES TO MSA FOR REVIEW AND COMMENT. 11. THE BUILDING OWNER OR THE OWNER'S AUTHORIZED REPRESENTATIVE SHALL ESTABLISH WORKING TIME AND STANDARDS OF CONDUCT. 12. DO NOT SCALE DRAWINGS. 13. THE GENERAL CONTRACTOR SHALL COORDINATE THE ACTIVITIES OF ALL SUBCONTRACTORS, DELIVERY, AND THE STAGING OF MATERIALS. MECHANICAL, PLUMBING, FIRE PROTECTION AND LIFE SAFETY NOTES 1. MECHANICAL, FIRE PROTECTION AND LIFE SAFETY ALTERATIONS AND CONSTRUCTION ARE BY OTHERS, UNDER SEPARATE PERMITS BY DESIGN BUILD CONTRACTORS - DEFERRED SUBMITTALS. 2. REBALANCE THE HVAC SYSTEM AND PROVIDE WRITTEN REPORT TO BUILDING REPRESENTATIVE. 3. CLEAN ALL DIFFUSERS & GRILLS. 4. VERIFY LOCATION OF THERMOSTATS WITH BUILDING REPRESENTATIVE PRIOR TO FINAL INSTALLATION. 5. ALL CONSTRUCTION WORK IS CONFINED TO THE BUILDING INTERIOR. CONTRACTOR SHALL PROVIDE BARRIERS OR SYSTEMS TO CONTAIN DUST, DIRT OR DEBRIS TO MINIMIZE INCONVENIENCE TO OTHER TENANTS WITHIN THE BUILDING. 6. CONSTRUCTION OPERATIONS SHALL NOT OBSTRUCT HALLWAYS, CORRIDORS, STAIRWAYS OR MEANS OF EGRESS FOR THE TENANTS OF THE BUILDING. 7. DO NOT DISRUPT HVAC, PLUMBING, ELECTRICAL OR FIRE PROTECTION SYSTEMS WITHOUT PRIOR AUTHORIZATION FROM BUILDING REPRESENTATIVE. 8. THE CONSTRUCTION SITE SHALL BE LEFT CLEAN & ORDERLY AT THE END OF EACH WORK DAY. 9. NO ONE WILL OCCUPY THE AREA OF WORK OTHER THAN AUTHORIZED CONSTRUCTION PERSONNEL. 10. THE GENERAL CONTRACTOR SHALL PROVIDE TEMPORARY CONSTRUCTION BARRIERS TO INHIBIT ACCESS BY NON -AUTHORIZED PERSONNEL & AS REQUIRED BY O.S.H.A. STANDARDS TO PREVENT INJURIES OR ACCIDENTS. 11. N.F.P.A. / I.F.C. APPROVED FIRE EXTINGUISHERS SHALL BE LOCATED WITHIN 75 FEET FROM ANY POINT ALONG THE PATH OF TENANT EGRESS OR AS REQUIRED BY THE LOCAL FIRE MARSHAL. 12. THE SPACE AROUND PIPES DUCTS ETC. PENETRATING FIRE RESISTANT CONSTRUCTION SHALL NOT EXCEED 1/2" & SHALL BE PACKED SOLID WITH APPROVED FIRE SAFING MATERIAL & SEALED WITH METAL ESCUTCHEONS EACH SIDE AS REQUIRED BY CODE. 13. MAINTAIN INTEGRITY OF RATED ASSEMBLIES AND REPAIR ANY DAMAGE TO SPRAY APPLIED FIRE PROOFING. SCOPE OF WORK / PROJECT NOTES NA TI -1 COVER SHEET AND DETAILS CITY OFUKWILA TI -2 DEMOLITION PLAN AND CONSTRUCTION PLAN FEB 22 2016 TI -3 REFLECTED CEILING PLAN AND ELEC./COMMUNICATION PLAN PERMIT CENTER TI -4 FINISH PLAN, FINISH SCHEDULE, ELEVATIONSI4SY cc,� Permft No. D LU Plan review approval is subject to errors and omissions. Approval of construction documents does not auihoiize tha violation of any adopted code or ordinance. Receipt of approved Field Copy a d conditions is se oy'Wird: SHEET INDEX 1 By: Date: City of 1 J3�3 BU! D1 ` SSON (c) NA SOUTHCENTER PLACE 16400 SOUTHCENTER PARKWAY TUKWILA; WASHINGTON 98188 8450 RI (;IsTEREI) tc.rrn) MAR' DOUGLAS EVANS STATE OF \V \SI1ING1"ON OP 1500 WESTLAKE AVE N. SUITE ONE. SEATTLE WA, 98109 (206) 441-1449 DRAWN BY: JK, BR CHECKED BY: LD JOB NO.: 78011.143 NO. REVISIONS INDICATED THUS 0 DATE BY PERMIT SET ISSUED FOR REVIEW 01/29/16 JK CONSTRUCTION DRAWINGS 02/17/16 BR ADD DW AND RELOCATE LT. FIX. 02/19/16 BR REVISIONS No changes shall be made to the of work without prior approval of Tukwila Building Division. NOTA:: r^:r 7 a will require a new plan submittal 1 & cJ r -,a7 1:-...,:u...) add :tion al plan review feel_ 1 TENANT: TERRA STAFFING GROUP SECOND FLOOR P�PA�1 SUITE 200 REVIEWED FOR CODE COMPLIANCE APPROVED SEPARATE REQUIR D FORA ,E7 Mecha .�'Electrica3 4.jG�Y �Iu�ttiiiGi� 5�ng City of Tukwila EUsl'ri) , DIVISION MAR 0 4 2016 City of Tukwila BUILDING DIVISION COVERSHEET AND DETAILS REPRODUCTION, ALTERATION OR PUBLICATION OF THIS DRAWING, WITHOUT EXPRESSED PERMISSION BY MSA, IS A VIOLATION OF FEDERAL COPYRIGHT LAW. COPYRIGHT BY MSA 2016. TI -1 OF 4 SOUTHCENTER PLACE 0 DEMOLITION LEGEND DEMOLITION PLAN 1/8" =1'-0" 5' 10' 20' EXISTING BUILDING CORE TO REMAIN. EXISTING HALLWAY PARTITION. EXISTING DEMISING PARTITION. EXISTING CONSTRUCTION TO REMAIN. EXISTING CONSTRUCTION TO BE DEMOLISHED. DEMOLITION KEYNOTES REMOVE EXISTING CASEWORK AND FIXTURES. PLUMBING LOCATION TO REMAIN FOR INSTALLATION OF NEW CASEWORK AND SINK. SEE CONSTRUCTION PLAN 2/TI-2. OREMOVE EXISTING ELECTRICAL OUTLET AND CONDUIT AT FLOOR. PREP FLOOR AS REQUIRED TO RECEIVE NEW FINISH. O3 REMOVE EXISTING ELECTRICAL AT THIS LOCATION. PATCH AND PREP WALL AS REQUIRED TO RECEIVE NEW PAINT. 30' DEMOLITION NOTES NORTH 1. A CLEAR PATH OF EGRESS TRAVEL SHALL REMAIN OPEN AT ALL TIMES DURING DEMOLITION. 2. DISRUPTION OF THE BUILDING FIRE ALARM, ELECTRICAL POWER, WATER, OR LIFE SAFETY SYSTEMS MUST BE COORDINATED WITH ALL GOVERNING AGENCIES AND THE BUILDING MANAGEMENT. 3. ALL DEBRIS SHALL BE REMOVED FROM THE CONSTRUCTION SITE DAILY. 4. ALL DEMOLITION SHALL BE PERFORMED IN ACCORDANCE WITH THE BUILDING MANAGEMENTS RULES AND REGULATIONS WITH MINIMAL DISTURBANCE TO OTHER TENANTS. 5. THE CONTRACTOR SHALL PROVIDE DUST BARRIERS FOR PROTECTION OF EXISTING ADJACENT AREAS. ALL HVAC SYSTEMS ARE TO BE PROTECTED DURING DEMOLITION. 6. THE CONTRACTOR SHALL NOTIFY BUILDING MANAGEMENT AND MSA OF ANY DEMOLITION WORK THAT IMPACTS THE STRUCTURAL INTEGRITY OF THE BUILDING. 7. THE GENERAL CONTRACTOR SHALL IMMEDIATELY REPORT ALL ACCIDENTS, ERRORS OR DEFECTS TO THE BUILDING MANAGEMENT. 8. PROVIDE DEMOLITION TO EXISTING WALLS, DOORS, CASEWORK, AND FLOORING AS REQUIRED. RECYCLING AND REUSE OF CONSTRUCTION MATERIALS IS HIGHLY ENCOURAGED WHERE APPROPRIATE. OFFICE (EXISTING) TELECOM EXISTING) OPEN WORK AREA MEETING (EXISTING) 204 KITCHEN COPY / WORK HALLWAY 1 205 1 MEETING •(EXISTING) 203 MEETING 206 RECEPTION CONFERENCE (EXISTING) 202 0 CONSTRUCTION LEGEND CONSTRUCTION PLAN 1/8" = 5' 10' 20' —• CWL EXISTING BUILDING CORE. EXISTING HALLWAY PARTITION. EXISTING DEMISING PARTITION. NEW B/S TENANT INTERIOR PARTITION. SEE DETAIL 11111-1. NEW COLD WATER LINE. riALIGN. CONSTRUCTION NOTES 1. MAINTAIN A CLEAR PATH OF TRAVEL AT ALL TIMES DURING CONSTRUCTION. 2. DISRUPTION OF THE BUILDING FIRE ALARM, ELECTRICAL POWER, WATER, OR LIFE SAFETY SYSTEMS MUST BE COORDINATED WITH ALL GOVERNING AGENCIES & THE BUILDING OWNER / MANAGEMENT AND TENANT. 3. INSTALL DOUBLE STUDS AT DOOR JAMBS AND HEADERS. 4. PROVIDE FIBER GLASS REINFORCED WATER RESISTANT GYPSUM BOARD IN AREAS SUSCEPTIBLE TO MOISTURE. 5. DIMENSIONS ARE FINISH SURFACE TO FINISH SURFACE, U.N.O. 6. REPORT ANY DISCREPANCIES BETWEEN THE DRAWINGS AND ACTUAL FIELD CONDITIONS TO MSA. 7. ALL EXISTING WINDOW COVERINGS TO BE CLEANED AND IN GOOD WORKING ORDER. CONSTRUCTION KEYNOTES 1O PROVIDE AND INSTALL NEW MAXIMUM WIDTH ALLOWED BIS FULL HEIGHT RELITE TO MATCH EXISTING RELITES IN SUITE. OPROVIDE AND INSTALL BLOCKING IN EXISTING PARTITION TO SUPPORT TENANT PROVIDED WALL MOUNTED WHITE BOARD. COORDINATE WITH TENANT. O3 EXISTING FIRE TREATED PLYWOOD PHONE BOARD TO REMAIN. COORDINATE WITH TENANT TO VERIFY ANY ADDITIONAL TELECOM REQUIREMENTS . O4 VERIFY THIS DIMENSION WITH THE TENANT FURNITURE AT THIS LOCATION TO ENSURE A PROPER FIT. PROVIDE AND INSTALL A BIS DISHWASHER AT EXISTING LOCATION. 30' NORTH DOOR SCHEDULE 6", UNLESS OTHERWISE NOTED NOTES: DOOR NUMBER TYPE OF DOOR A. NEW BIS 3'-0" WIDE X FULL HEIGHT X 1-3/4" THICK SC WOOD DOOR IN BIS WOOD FRAME TO MATCH EXISTING IN SUITE. HARDWARE a. BIS LATCHSET. EXISTING DOOR TO REMAIN 1. PROVIDE CODE COMPLIANT HARDWARE. ALL HARDWARE TO BE LEVER -TYPE. HANDLES, PULLS, LATCHES, LOCKS, AND OTHER OPERABLE PARTS ON ACCESSIBLE DOORS SHALL HAVE A SHAPE THAT IS EASY TO GRASP WITH ONE HAND AND DOES NOT REQUIRE TIGHT GRASPING, PINCHING, OR TWISTING OF THE WRIST TO OPERATE. OPERABLE PARTS OF SUCH HARDWARE SHALL BE 34" MIN. AND 48" MAX. ABOVE THE FLOOR. 2. THE MAXIMUM FORCE FOR PUSHING OR PULLING OPEN DOORS OTHER THAN FIRE DOORS SHALL BE AS FOLLOWS: INTERIOR HINGED DOOR = 5.0 POUNDS (22.2 N), SLIDING OR FOLDING DOOR =15.0 POUNDS (67 N). THESE FORCES DO NOT APPLY TO THE FORCE REQUIRED TO RETRACT LATCH BOLTS OR DISENGAGE OTHER DEVICES THAT HOLD THE DOOR IN A CLOSED POSITION. FIRE DOORS SHALL HAVE A MINIMUM OPENING FORCE ALLOWABLE BY THE APPROPRIATE ADMINISTRATIVE AUTHORITY. 3. THRESHOLDS AT DOORWAYS SHALL NOT EXCEED 0.5 INCH (12.7 MM) IN HEIGHT. RAISED THRESHOLDS AND FLOOR LEVEL CHANGES GREATER THAN 0.25 INCH (6.4 MM) AT DOORWAYS SHALL BE BEVELED WITH A SLOPE NOT GREATER THAN ONE UNIT VERTICAL IN TWO UNITS HORIZONTAL (50 -PERCENT SLOPE). 4. EXIT DOORS MUST REMAIN UNLOCKED AT ALL TIMES IN THE DIRECTION OF EGRESS. PASSAGE EXIT HARDWARE SHALL REQUIRE NO SPECIAL KNOWLEDGE OR ASSISTANCE TO OPEN OR TO ACCESS. D04 RECEIVED CITY OF TUKWILA FEB 22 2016 PERMIT CENTER SOUTHCENTER PLACE 16400 SOUTHCENTER PARKWAY TUKWILA, WASHINGTON 98188 8459 Rt -if i i c RK DOUGLAS EVA STATE 01 \VASIIIN(iFON 1500 WESTLAKE AVE N SUITE ONE, SEATTLE WA, 98109 (206) 441-1449 DRAWN BY: JK, BR CHECKED BY: LD JOB NO.: 78011.143 NO. REVISIONS INDICATED THUS n DATE BY PERMIT SET ISSUED FOR REVIEW 01/29/16 JK CONSTRUCTION DRAWINGS 02/17/16 BR ADD DW AND RELOCATE LT. FIX. 02/19/16 BR TENANT: TERRA STAFFING GROUP SECOND FL (SUITE 2 IEWED FOR DE COMPLIANCE APPROVED MAR 0 4 2016 SHEET TITLE: DEMOLITION AND CONSTRUCTION PLAN City of Tukwila BUILDING DIVISION REPRODUC110N, ALTERATION OR PUBLICATION OF THIS DRAWING, WITHOUT EXPRESSED PERMISSION BY MSA, IS A VIOLATION OF FEDERAL COPYRIGHT LAW. COPYRIGHT BY MSA 2016. TI -2 OF 4 II w V J a - LL -1 w U 0 i� 1' 211 LTJ 201 0 CEILING LEGEND REFLECTED CEILING PLAN 1/8" =1'-0" 5' 10' 20' (N) EXISTING CEILING GRID AND TILES TO REMAIN. EXISTING 2X4' RECESSED FLUORESCENT LIGHT FIXTURES TO REMAIN. EXISTING 2'X4' RECESSED FLUORESCENT LIGHT FIXTURES TO BE UPGRADED FOR EMERGENCY LIGHTING. LAYOUT SHOWN IS CONCEPTUAL ONLY. EXISTING 2'X4' RECESSED FLUORESCENT LIGHT FIXTURES TO BE REMOVED/RELOCATED. NEW OR RELOCATED BIS 2'X4' RECESSED FLUORESCENT LIGHT FIXTURES. NEW OR RELOCATED BIS 2'X4' RECESSED FLUORESCENT LIGHT FIXTURES TO BE UPGRADED FOR EMERGENCY LIGHTING. LAYOUT SHOWN IS CONCEPTUAL ONLY. NEW ILLUMINATED EXIT SIGN (DIRECTIONAL WHERE SHOWN). B/S LIGHT SWITCH. (M = SUITE MASTER, N = NEW) EXISTING EXHAUST FAN. 30' NORTH CEILING NOTES 203 1. CHECK FOR CONFLICTS BEFORE INSTALLING OR RELOCATING LIGHT FIXTURES. NOTIFY MSA OF ANY CONFLICT(S). 2. REPLACE DAMAGED CEILING TILES AND GRID AS NECESSARY TO BRING CEILING TO "LIKE NEW" CONDITION. 3. MAINTAIN EXISTING ONE FOOTCANDLE PER SQUARE FOOT AT EGRESS PATHWAY LIGHTING. 4. MAINTAIN 42" CLEAR SPACE IN FRONT OF THE PANEL SIDE OF ANY V.A.V. BOXES. 5. DAYLIGHT ZONE CONTROL: DAY LIGHTING AS DEFINED BY CODE SHALL BE PROVIDED WITH INDIVIDUAL CONTROLS, OR DAYLIGHT OR OCCUPANT SENSING AUTOMATIC CONTROLS PER SECTION C405.2.2.2 OF THE WASHINGTON STATE ENERGY CODE. 6. FIRE SPRINKLER INSTALLATION TO BE DESIGN -BUILD WITH DEFERRED PERMIT SUBMITTALS. 7. COMMISSIONING REQUIREMENTS: TEST LIGHTING CONTROLS TO ENSURE THAT THE SYSTEMS COMPLY WITH CODES. PROVIDE A WRITTEN REPORT OF TEST PROCEDURES AND RESULTS TO THE OWNER. USE OCCUPANCY SENSORS AS REQUIRED. 8. EXIT SIGNS ARE INDICATED ON THE REFLECTED CEILING PLAN. THEIR FINAL PLACEMENT IS TO BE COORDINATED IN THE FIELD WITH THE INSPECTOR. LIGHTING CALCULATION EXISTING LIGHTING LAYOUT USES 35 FIXTURES. THE PROPOSED LAYOUT RELOCATES 4 OF THE EXISTING FIXTURES. 4/35 x 100 =11.43% WHICH IS LESS THAN THE 60% ALLOWABLE CHANGE PER 2012 WSEC LIGHTING ALTERATION EXCEPTION C101.4.3.1. EXISTING WATTAGE STAYS THE SAME. ELEC./COMMUNICATION PLAN 1 /8" =1'-0" 0 ELEC / COMMUNICATIONS LEGEND 5' 10' 20' B/S WALL MOUNTED DUPLEX ELECTRICAL OUTLET B/S WALL MOUNTED DEDICATED 120V 20A DUPLEX ELECTRICAL OUTLET B/S WALL MOUNTED FOURPLEX ELECTRICAL OUTLET B/S WALL MOUNTED COMBINATION VOICE/DATA OUTLET BLANK FACE PLATE NEW NEW B/S ELECTRICAUCOMMUNICATIONS WHIP. LOCATION SHOWN IS CONCEPTUAL ONLY. CONTRACTOR TO COORDINATE FINAL LOCATION WITH TENANT. SYMBOLS SHOWN INDICATE POWER, VOICE & DATA, SEE SYMBOLS ABOVE FOR REQUIREMENTS. (#) = NUMBER OF WORKSTATIONS SERVED. (N=NEW) 30' NORTH 203 ELEC. / COMMUNICATION NOTES • 1. ALL ELECTRICAL OUTLETS TO BE MOUNTED AT 15" A.F.F. (AT BASE OF OUTLET) PER I.B.C. REQUIREMENTS U.N.O. 2. ROUGH IN ALL DATA AND COMMUNICATION LINES - MUD RING WITH PULL STRING, U.N.O. 3. PROVIDE NEW COVER PLATES AND RECEPTACLES AS NEEDED TO MATCH BUILDING STANDARD. 4. MAINTAIN EXISTING ELECTRICAL OUTLETS UNLESS LOCATION CONFLICTS WITH NEW CONSTRUCTION. bt 0011 9 CITY RECEIVED TUKWILA FEB 22 2016 PERMIT CENTER SOUTHCENTER PLACE 16400 SOUTHCENTER PARKWAY TUKWILA, WASHINGTON 98188 K DOUGLAS STATE OF WASHINGTON 1500 WESTLAKE AVE N. SUITE ONE, SEATTLE WA, 98109 (206) 441-1449 DRAWN BY: JK, BR CHECKED BY: LD JOB NO.: 78011.143 NO. REVISIONS INDICATED THUS 0 DATE BY PERMIT SET ISSUED FOR REVIEW 01/29/16 JK CONSTRUCTION DRAWINGS 02/17/16 BR ADD DW AND RELOCATE LT. FIX. 02/19/16 BR TENANT: TERRA STAFFING GROUP SECOND FLOOR (SUITE 1 VIEWED FOR CO I E COMPLIANCE APPROVED MAR 0 4 2016 SHEET TITLE: REFLECTED CEI!"�q�N AND ELEC./COMMUNICATION PLAN REPRODUCTION, ALTERATION OR PUBLICATION OF THIS DRAWING, WITHOUT EXPRESSED PERMISSION BY MSA, IS A VIOLATION OF FEDERAL COPYRIGHT LAW. COPYRIGHT BY MSA 2016. TI -3 OF 4 SOUTHCENTER PLACE ai iiiiji �E0oaj oI-cnox 0 FINISH NOTES FINISH PLAN 1/8" =1'-0" 5' 10' 20' 1. ALL WALLS TO RECEIVE 2. ALL ROOMS TO RECEIVE 3. BASE , U.N.O. CPT -1 , U.N.O. TO BE USED THROUGHOUT, U.N.O. 4. PROVIDE ROPPE "TILE/CARPET JOINER #50" IN COLOR (TBD - TO MATCH B-1) AT ALL CARPET TO VCT FLOORING TRANSITIONS. 30' NORTH FINISH KEYNOTES OVERIFY WITH TENANT THE CARPET TILE LAYOUT, CPT -2 AS THE GENERAL CARPET TILE AND CPT -3 AS A RANDOM ACCENT TILE. VERIFY CPT -3 -HALF TILE PLACEMENT. OVERIFY WITH TENANT THE VCT LAYOUT, VCT -2 AS THE GENERAL TILE AND VCT -1 AS A RANDOM ACCENT TILE. VERIFY VCT -1 -HALF TILE PLACEMENT. FINISH SCHEDULE SYMBOL/NO. DESCRIPTION MANUFACTURER STYLE COLOR / FINISH SIZE NOTES 0 CARPET BROADLOOM SHAW TERRA 5A037 BLACK GUM 37500 12'-0" NA CPT -1 0 CARPET TILE SHAW PRISMA 59463 OPAQUE BLACK 63500 24" X 24" 1/4" TURN; ALTERNATIVE - SHAW, TANGLE TILE 5T018, DARE 18505 CPT -2 0 CARPET TILE MANNINGTON COMMERCIAL SENTANA GINKGO 4338 24" X 24" 1/4" TURN; ALTERNATIVE - SHAW, TRUE COLORS 59368, BRITE GREEN 68325 CPT -3 0 VINYL COMPOSITECHALK TILE ARMSTRONG EXCELON STONETEX WHITE 52140 12" X 12" INSTALL AND SEAL PER MANUFACTURER'S INSTRUCTIONS VCT -1 VINYL COMPOSITE TILE ARMSTRONG EXCELON STONETEX COAL BLACK 52144 12" X 12" INSTALL AND SEAL PER MANUFACTURER'S INSTRUCTIONS VCT -2 0 GENERAL PAINT SHERWIN WILLIAMS LATEX, MATTE EXTRA WHITE SW7006 NA NA 0 ACCENT PAINT SHERWIN WILLIAMS LATEX, MATTE FROLIC SW6703 NA NA 0 ACCENT PAINT SHERWIN WILLIAMS LATEX, MATTE REFUGE SW6228 NA NA P-4 ACCENT PAINT SHERWIN WILLIAMS LATEX, MATTE AMBER WAVE SW6657 NA RUBBER BASE JOHNSONITE TRADITIONAL WALL BASE CHARCOAL 20 4" HEIGHT NA imp PL -1 PLASTIC LAMINATE PIONITE SUEDE FINISH WHITE SW811 TBD COUNTER TOP AND UPPER CABINETS 43) PLASTIC LAMINATE PIONITE SUEDE FINISH SABLE AG021 TBD VERTICAL GRAIN; EXTERIOR LOWER CABINETS M (0 N c) \ / \ / \ / X / \ r LiAN N i0 M (3) EQ. /\ NOTES: 1. PROVIDE FINISHED ENDS ON ALL EXPOSED SURFACES, TYP. 2. PROVIDE FILLER PANELS AS NECESSARY, TYP. / \� yN / \� • VERIFY 1 36" PER ELEVATION ()ELEVATION 3/8" _r_�,� =1'-0" (2) EQ. ELEVATION 3/8" =1'-0" MIN_ DIM.-' 12" (INSIDE CLEAR) �if/ / 0 X I ■ 0 BY 0 TYP. 01/29/16 0 0 CONSTRUCTION DRAWINGS /\ /__ a /\ __\ _ 0 _,/ 0 0 TYP. 0 0 0 0 .moil. .�/. A 0 �Nv 0 0 1 72" (2 EQ.) ELEVATION 3/8" =1'-0" MIN_ DIM.-' 12" (INSIDE CLEAR) �if/ / 0 X I ■ 0 BY 0 0 01/29/16 0 0 CONSTRUCTION DRAWINGS 02/17/16 a 0 0 BR 0 0 0 0 0 0 0 0 0 0 0 0 ®SECTION 1-1/2" -1' =1'-0" 25" I VERIFY WITH DISHWASHER PLAM FILLER PANEL. ENSURE FULL OPERATION OF DOORS, TYP. BIS PLAMVUPPER CABINET WITH DOORS AND (2) ADJUSTABLE SHELVES. B/S A.N.S.I: APPROVED PLAM SINK CABINET (NO BOTTOM @ BASE) WITH A.N.S.I.- COMPLIANT SINK & FAUCET. BIS PLAM COUNTER TOP AND BACKSPLASH. B/S PLAM LOWER CABINETS WITH DRAWERS, DOORS AND ADJUSTABLE SHELF. NOTES: 1. PROVIDE FINISHED ENDS ON ALL EXPOSED SURFACES, TYP. 2. PROVIDE FILLER PANELS AS NECESSARY, TYP. PLAM FILLER PANEL. ENSURE FULL OPERATION OF DOORS, TYP. BIS PLAM UPPER CABINET WITH DOORS AND (2) ADJUSTABLE SHELVES. B/S PLAM COUNTER TOP AND BACKSPLASH. B/S PLAM LOWER CABINET WITH (2) DRAWERS, DOORS AND ADJUSTABLE SHELF. (2) B/S CONCEALED HINGES PER DOOR. 1/4" PLYWOOD BACKING WITH MELAMINE FINISH. 3/4" PLYWOOD ADJUSTABLE SHELF WITH FINISH MELAMINE FINISH. MELAMINE INTERIOR. CABINET DOORS. P -LAM FINISH ON EXPOSED FACE WITH MATCHING B/S EDGE BANDING AND MELAMINE FINISH ON INTERIOR FACE. BIS ADA -COMPLIANT CASEWORK HARDWARE. 3/4" PLAM BACKSPLASH. PROTECTIVE COVERING AT EXPOSED PIPES. 25" 24" B/S S.S. FAUCET & SINK PER ANSI 117.1 CODE COMPLIANCE BIS PLAM f____ COUNTERTOP, PER SCHEDULE. 1/4" PLYWOOD BACKING WITH MELAMINE FINISH. DASHED LINES INDICATE REQUIRED ACCESSIBLE CLEARANCES. — kr M CONTINUE FINISH FLOOR BELOW SINK RESILIENT BASE, PER SCHEDULE. 6" MIN. CLR. PER ELEVATION B/S ADA- COMPLIANT CASEWORK HARDWARE 8" MIN. CLR. (2) CONCEALED HINGES PER EACH DOOR. SECTION 1-1/2" =1'-0" 25" CABINET DOORS. P -LAM FINISH ON EXPOSED FACE WITH MATCHING EDGE BANDING AND MELAMINE FINISH ON INTERIOR FACE. PL -2 27" MIN. CLR. N \—\ ATTACH BASE TO DOOR. CUT BASE SHORT FOR PROPER DOOR OPERATION. olte/ I PLAM COUNTERTOP AND 3/4" BACKSPLASH.• pL-1 0 0 0 MELAMINE INTERIOR AS SCHEDULED 0 0 0 0 0 0 mood x MIN DIM. 24" SECTION 1-1/2" =1'-0" 3 DRAWER ON (75) POUND FULL- EXTENSION SLIDE. B/S ADA -COMPLIANT CASEWORK HARDWARE, TYP. (2) CONCEALED HINGES PER DOOR. ADJUSTABLE SHELF WITH MELAMINE FINISH. CABINET DOORS. P -LAM FINISH ON EXPOSED FACE WITH MATCHING EDGE BANDING AND MELAMINE FINISH ON INTERIOR FACE. 1/4" PLYWOOD BACKING WITH MELAMINE FINISH. BASE AS SCHEDULED. RECEIVED CITY OF TUKWILA FEB 22 2016 PERMIT CENTER SOUTHCENTER PLACE 16400 SOUTHCENTER PARKWAY TUKWILA, WASHINGTON 98188 8459 REGISTERED ARCMIL;l� - 1'' DO GLAS EVANS STATE ()I' (NASI IIN(I ION 1S00 WESTLAKE AVE N. SUITE ONE, SEATTLE WA, 98109 (206) 441-1449 DRAWN BY: JK, BR CHECKED BY: LD JOB NO.: 78011.143 NO. REVISIONS INDICATED THUS ,L DATE BY PERMIT SET ISSUED FOR REVIEW 01/29/16 JK CONSTRUCTION DRAWINGS 02/17/16 BR ADD DW AND RELOCATE LT. FIX. 02/19/16 BR TENANT: TERRA STAFFING GROUP SECOND FLOOR (SUITE ZO0)— REVIEWEDFOR SHEET TITLE: CODE COMPLIANCE APPROVED MIR 1 2Q1S FINISH PL NCity of Tukwila GJILDING DIVISION FINISH SCHEDULE, ELEVATIONS AND SECTIONS REPRODUCTION, ALTERATION OR PUBLICATION OF THIS DRAWING, WITHOUT EXPRESSED PERMISSION BY MSA, IS A VIOLATION OF FEDERAL COPYRIGHT LAW. COPYRIGHT BY MSA 2016. TI -4 OF 4 SOUTHCENTER PLACE