Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Permit D16-0056 - THORNDYKE ELEMENTARY SCHOOL - MAIN ENTRY DOORS
THORNDYKE ELEMENTARY SCHOOL 4415 S 150 ST D16-0056 Parcel No: Address: City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-438-9350 Web site: http://www.TukwilaWA.gov DEVELOPMENT PERMIT 0042000280 Permit Number: 4415 S 150TH ST Issue Date: Permit Expires On: Project Name: THORNDYKE ELEMENTARY SCHOOL D16-0056 3/30/2016 9/26/2016 Owner: Name: Address: Contact Person: Name: Address: Contractor: Name: Address: TUKWILA SCHOOL DISTRICT 4640 S 144TH ST, TUKWILA, WA, 98168 LILIANA CARDENAS 4640 S 144 ST , TUKWILA, WA, 98168 FORMA CONSTRUCTION COMPANY PO BOX 11489 , OLYMPIA, WA, 98508- 1489 License No: FORMACC878OR Lender: Name: TUKWILA SCHOOL DISTRICT Address: 4640 S 144TH ST, TUKWILA, WA, 98168 Phone: (206) 901-8020 Phone: (360) 754-5788 Expiration Date: 9/19/2017 DESCRIPTION OF WORK: INSTALLATION OF SECOND SET OF MAIN ENTRY DOORS TO CREATE A SECURITY VESTIBULE TO CONTROL VISITOR TRAFFIC INTO THE BUILDING Project Valuation: $29,345.00 Type of Fire Protection: Sprinklers: YES Fire Alarm: YES Type of Construction: VB Electrical Service Provided by: TUKWILA FIRE SERVICE Fees Collected: $1,155.24 Occupancy per IBC: E Water District: 125 Sewer District: VALLEY VIEW SEWER SERVICE Current Codes adopted by the City of Tukwila: International Building Code Edition: International Residential Code Edition: International Mechanical Code Edition: Uniform Plumbing Code Edition: International Fuel Gas Code: 2012 2012 2012 2012 2012 National Electrical Code: WA Cities Electrical Code: WAC 296-46B: WA State Energy Code: 2014 2014 2014 2012 Public Works Activities: Channelization/Striping: Curb Cut/Access/Sidewalk: Fire Loop Hydrant: Flood Control Zone: Hauling/Oversize Load: Land Altering: Landscape Irrigation: Sanitary Side Sewer: Sewer Main Extension: Storm Drainage: Street Use: Water Main Extension: Water Meter: Volumes: Cut: 0 Fill: 0 Number: 0 No Permit Center Authorized Signature: t/l/ Date: �(44 I hearby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this development permit and agree to the conditions attached to this permit. Signature: Print Name: CA (.1 it. 9— Ode. -v4-3 Date: 3 3° I fo This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 3: Fire protection systems shall be maintained in accordance with the original installation standards for that system. Required systems shall be extended, altered or augmented as necessary to maintain and continue protection whenever the building is altered, remodeled or added to. Alterations to fire protection systems shall be done in accordance with applicable standards. (IFC 901.4) 1: All new sprinkler systems and all modifications to existing sprinkler systems shall have fire department review and approval of drawings prior to installation or modification. New sprinkler systems and all modifications to sprinkler systems involving more than 50 heads shall have the written approval of Factory Mutual or any fire protection engineer licensed by the State of Washington and approved by the Fire Marshal prior to submittal to the Tukwila Fire Prevention Bureau. No sprinkler work shall commence without approved drawings. (City Ordinance No. 2436). 5: Maintain automatic fire detector coverage per N.F.P.A. 72. Addition/relocation of walls, closets or partitions may require relocating and/or adding automatic fire detectors. 6: Maintain fire alarm system audible/visual notification. Addition/relocation of walls or partitions may require relocation and/or addition of audible/visual notification devices. (City Ordinance #2437) 4: All new fire alarm systems or modifications to existing systems shall have the written approval of The Tukwila Fire Prevention Bureau. No work shall commence until a fire department permit has been obtained. (City Ordinance #2437) (IFC 901.2) 2: Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (City Ordinances #2436 and #2437) 7: Any overlooked hazardous condition and/or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. 8: These plans were reviewed by Inspector 511. If you have any questions, please call Tukwila Fire Prevention Bureau at (206)575-4407. 9: ***BUILDING PERMIT CONDITIONS*** 10: Work shall be installed in accordance with the approved construction documents, and any changes made during construction that are not in accordance with the approved construction documents shall be resubmitted for approval. 11: All permits, inspection record card and approved construction documents shall be kept at the site of work and shall be open to inspection by the Building Inspector until final inspection approval is granted. 12: All construction shall be done in conformance with the Washington State Building Code and the Washington State Energy Code. 13: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of this requirement. 14: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center. 15: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 1700 BUILDING FINAL** 1400 FIRE FINAL 0409 FRAMING 0606 GLAZING CITY OF TUK, LA Community Development Department Public Works Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.TukwilaWA.gov Building Permit No. bi (p— 00,10 Project No. Date Application Accepted: S--H-[ BH—[ 'f9 Date Application Expires: (For office use only) CONSTRUCTION PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **Please Print** SITE LOCATION King Co Assessor's Tax No.: 004 1000 as 0 Site Address: 4Y 1 S SOU 11 1 'S 1- 4A 101 2) (o $ Suite Number: Tenant Name: 1"QIC..Q t lam- 5 cat,00 k si>1 Si`tAeA- PROPERTY OWNER Name: LA ClounCs. CAI_A2-1-4/tr Address: t 4 0 `(/ (j (/4 \s,,r City: "f�� tti1 tState•:wt_ Zip: civ);61c. Name: -rUi<LUI 1 Email: C-ardeVIC% t -P 1-U444/ I (G . (.C.l°Git a . S Ch00 0 >STIZ . CA-- A"Address: Address: LeCoLt'p s ' s r Fax: City: (1 State: Contr Reg No.: Stater Zip: a8 I b S CONTACT PERSON - person receiving all project communication Name: LA ClounCs. CAI_A2-1-4/tr Address: t 4 0 `(/ (j (/4 \s,,r City: "f�� tti1 tState•:wt_ Zip: civ);61c. Phone: 2,06,-i0t 01 --gam Fax: 2-06-410 (- 8 O iiia Email: C-ardeVIC% t -P 1-U444/ I (G . (.C.l°Git a . GENERAL CONTRACTOR INFORMATION Company Name: Address: Address: $ Lt fit,, � 7� City: O 1 u K�. State: w Zip: 1 g l Phone: _ ki$ I. c{ Z.0 Fax: 3100 , 3 5-2.- q t 5.3 City: State: Zip: Phone: Fax: City: State: Contr Reg No.: Phone: Exp Date: Tukwila Business License No.: H:\Applications\Forms-Applications On Line\2012 Applications\Permit Application Revised - 2-7-12.docx Revised: February 2012 bh d� Floor: New Tenant: ❑ Yes E. No ARCHITECT OF RECORD Company Name: kKi3 Of'Pl ro toq,0r.) P T�_c_. Architect Name: zsze__ Ceeh Address: $ Lt fit,, � 7� City: O 1 u K�. State: w Zip: 1 g l Phone: _ ki$ I. c{ Z.0 Fax: 3100 , 3 5-2.- q t 5.3 Email: - ecc_ceevvet-( p le. 1.4gdpSIbitJ . Gc9yi ENGINEER OF RECORD Name: 4riW 1 Company Name: Address: 40 4(0 Engineer Name: Nct S Address: State: KM- City: State: Zip: Phone: Fax: Email: LENDER/BOND ISSUED (required for projects $5,000 or greater per RCW 19.27.095) Name: 4riW 1 Address: 40 4(0 5 Nct S City: -flJJlt.4.- State: KM- Zip: clg Iei Page 1 of 4 BUILDING PERMIT INFORMATIC 206-431-3670 Valuation of Project (contractor's bid price): $ 2-'9‘ J 4 S Existing Building Valuation: $ Describe the scope of work (please provide detailed information): J+v s'ra-111ck)t--, —) Sre 1- 014 pa;,.) o, oon s -�- o tJtie w-rr P. S rpt UP) L e -io ookrted U l cA' L- 1••1 z , (-41 fit] ( (otl. &) 6 Will there be new rack storage? ❑ ....Yes No If yes, a separate permit and plan submittal will be required. Provide All Building Areas in Square Footage Below PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq 11): Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact: Handicap: Will there be a change in use? ❑ Yes V No If "yes", explain: FIRE PROTECTION/HAZARDOUS MATERIALS: Er Sprinklers izrAutomatic Fire Alarm ❑ None 0 Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? 0 Yes Er No If `yes', attach list of materials and storage locations on a separate 8-1/2" x II" paper including quantities and Material Safety Data Sheets. SEPTIC SYSTEM ❑ On-site Septic System — For on-site septic system, provide 2 copies of a current septic design approved by King County Health Department. H: Applications\Forms-Applications On Line \2012 ApplicationsU'ermit Application Revised - 2-7-12.docx Revised: February 2012 bh Page 2 of 4 Existing Interior Remodel Addition to Existing Structure New Type of Construction per IBC Type of Occupancy per IBC 1St Floor 2nd Floor 3rd Floor Floors thru Basement Accessory Structure* Attached Garage Detached Garage Attached Carport Detached Carport Covered Deck Uncovered Deck PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq 11): Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact: Handicap: Will there be a change in use? ❑ Yes V No If "yes", explain: FIRE PROTECTION/HAZARDOUS MATERIALS: Er Sprinklers izrAutomatic Fire Alarm ❑ None 0 Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? 0 Yes Er No If `yes', attach list of materials and storage locations on a separate 8-1/2" x II" paper including quantities and Material Safety Data Sheets. SEPTIC SYSTEM ❑ On-site Septic System — For on-site septic system, provide 2 copies of a current septic design approved by King County Health Department. H: Applications\Forms-Applications On Line \2012 ApplicationsU'ermit Application Revised - 2-7-12.docx Revised: February 2012 bh Page 2 of 4 PERMIT APPLICATION NOTES — Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNE OR AUTHORIZED AGENT: Signature: Date: ) q) 001 Print Name: L -i �-1 (MA- COECi.2A41--b Day Telephone: ZOG "-Ot Ol Mailing Address: L( q0 S IL( 1-1,0-4/ 1 — B 6& City H:\Applications\Forms-Applications On Line\2012 Applications\Permit Application Revised - 2-7-12.docx Revised: February 2012 bh State Zip Page 4 of 4 [PUBLIC WORKS PERMIT INE MATION — 206-433-0179 Scope of Work (please provide detailed information): Call before you Dig: 811 Please refer to Public Works Bulletin #1 for fees and estimate sheet. Water District ❑ .. Tukwila ❑ ...Water District #125 ❑ .. Water Availability Provided Sewer District ❑ .. Tukwila ❑ .. Sewer Use Certificate ❑... Highline ❑ ...Valley View ❑ ... Renton ❑ ...Sewer Availability Provided 0... Renton 0... Seattle Septic System: 0 On-site Septic System — For on-site septic system, provide 2 copies of a current septic design approved by King County Health Department. Submitted with Application (mark boxes which apply): 0 .. Civil Plans (Maximum Paper Size — 22" x 34") 0 .. Technical Information Report (Storm Drainage) ❑ .. Bond 0... Insurance 0... Easement(s) Proposed Activities (mark boxes that apply): 0 .. Right-of-way Use - Nonprofit for less than 72 hours ❑ .. Right-of-way Use - No Disturbance ❑ .. Construction/Excavation/Fill - Right-of-way 0 Non Right-of-way ❑ ❑ .. Total Cut ❑ .. Total Fill cubic yards cubic yards ❑ .. Sanitary Side Sewer ❑ .. Cap or Remove Utilities 0 .. Frontage Improvements ❑ .. Traffic Control ❑ .. Backflow Prevention - Fire Protection Irrigation Domestic Water 0... Geotechnical Report 0...Maintenance Agreement(s) ❑ .. Traffic Impact Analysis ❑ .. Hold Harmless — (SAO) ❑ .. Hold Harmless — (ROW) 0...Right-of-way Use - Profit for less than 72 hours 0...Right-of-way Use — Potential Disturbance 0...Work in Flood Zone 0... Storm Drainage 0... Abandon Septic Tank ❑... Curb Cut 0...Pavement Cut 0...Looped Fire Line ❑ .. Permanent Water Meter Size (1) " WO # 0 .. Temporary Water Meter Size (1) " WO # 0 .. Water Only Meter Size WO # ❑ .. Sewer Main Extension Public 0 Private ❑ 0 .. Water Main Extension Public 0 Private 0 0... Grease Interceptor ❑ ... Channelization ❑ ... Trench Excavation 0... Utility Undergrounding (2) " WO # (3) " WO # (2) " WO # (3) " WO # ❑ .. Deduct Water Meter Size FINANCE INFORMATION Fire Line Size at Property Line 0 .. Water 0 .. Sewer 0 .. Sewage Treatment Monthly Service Billing to: Name: Number of Public Fire Hydrant(s) Day Telephone: Mailing Address: City State Zip Water Meter Refund/Billing: Name: Mailing Address: Day Telephone: City State Zip H: Applications\Forms-Applications On Line\2012 Applications\Permit Application Revised - 2-7-12.docx Revised: February 2012 bh Page 3 of 4 Cash Register Receipt City of Tukwila DESCRIPTIONS PermitTRAK I ACCOUNT I QUANTITY I PAID $715.25 D16-0056 Address: 4415 S 150TH ST Apn: 0042000280 $715.25 DEVELOPMENT $681.40 PERMIT FEE R000.322.100.00.00 0.00 $676.90 WASHINGTON STATE SURCHARGE B640.237.114 0.00 $4.50 TECHNOLOGY FEE $33.85 TECHNOLOGY FEE TOTAL FEES PAID BY RECEIPT: R8055 R000.322.900.04.00 0.00 $33.85 $715.25 Date Paid: Wednesday, March 30, 2016 Paid By: LILIANA CARDENAS Pay Method: CREDIT CARD 004326 Printed: Wednesday, March 30, 2016 9:03 AM 1 of 1 CRI(SYSTEMS Cash Register Receipt City of Tukwila DESCRIPTIONS I ACCOUNT 1 QUANTITY PAID PermitTRAK $439.99 D16-0056 Address: 4415 S 150TH ST Apn: 0042000280 $439.99 DEVELOPMENT $439.99 PLAN CHECK FEE TOTAL FEES PAID BY RECEIPT: R7834 R000.345.830.00.00 0.00 $439.99 $439.99 Date Paid: Friday, March 04, 2016 Paid By: LILIANA CARDENAS Pay Method: CREDIT CARD 024003 Printed: Friday, March 04, 2016 1:24 PM 1 of 1 C?SYSTEMS INSPECTION RECORD Retain a copy with permit PECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION _(df 6300 Southcenter Blvd:, #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project: �� lf�l//.1 Type oblrtsIctio ( c c � i Ad re�s{s: ( (J 55,(11) S1. Date Called: Special Instructions: E. ,/� /� 1 ✓1 1 Date Wa ted: I._7 —/� t a.m. p.m. Requester:ll, p PV( one No: Z-7(3`. ct/ Approved per applicable codes. Corrections required prior to approval. OMMENTS: ot trfrq/ (4.c G (plc, Our s tbiCilqVce f nspector: Date: REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit IN PECTION NO. PERMIT NO. 1) (6®os-,6 CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Proj ct:Type drvo( e ice of Ins ectio41: & (a v Addre�s(s: Date Called: Special Instructions: pm Date/Wa~ntted: L —/ •— 1,6 a.m. p.m. Requester: Phone No: Approved per applicable codes. E ] Corrections required prior to approval. OMMENTS: inspector: Ler,_ Date: 4-7 REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. 1011111 SPECTION NO. INSPECTION RECORD Retain a copy with permit D(6 rt PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 Permit Inspection Request Line (206) 438-9350 (206) 431-3670 Project: / Type of Inspection: ALr f(r PO , (J-0 fri` f f, Date Called: Special Instructions:. P4 rfrild i& `1) a (1 AM Date Wanted: �'%- r —( % a.m. p.m. Reque�te : Phone No: Approved per applicable codes. LJ Corrections required prior to approval. COMMENTS: C c �l f % lvs'� o rtir( d Go f/ Inspector: rc Date: REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. INSPECTION NUMBER INSPECTION RECORD Retain a copy with permit D�4- ()ds y PERMIT NUMBERS CITY OF TUKWILA FIRE DEPARTMENT 206-575-4407 Project: 1 k uckt ke -P I l�),� , Type_of Inspection: 1 lQ. l IA.,:/N. Address: U c( IS`' Suite #: S / S o 1-,- Contact Person: -"- Special Instructions: y, L.A./ vrc._ Phone No.: (Approved per applicable codes. Corrections required prior to approval. COMMENTS: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire N, f -Q._ y, L.A./ vrc._ -- 0 ic.... . Needs Shift Inspection: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire Permits: Occupancy Type: Inspector: k., P7. --Date: yb/i b Hrs.: 4 $100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. Billing Address Attn: Company Name: Address: City: State: Zip: Word/Inspection Record Form.Doc 3/14/14 T.F.D. Form F.P. 113 INA sHIMOT0N £PC1117[CTli #I 1. MARDWANE CO. iFoNNNIminpimo HEADING 1 (HARDWARE GROUP 1) DOOR #101A, EXTERIOR STOREFRONT, DOUBLE 3'0" X 7'0" DOOR OPENING, AL X AL 6 EA. MCKINNEY BUTTS 1 EA VON EXIT 1 EA. VON EXIT 1 EA. VON MULLION T4A3786 NRP RX-EL98L X 990NL X RHR 4.5 X 4.5 36" RX-EL98DT X 990DT X LHR 36" KR4954 2 EA. VON POWER TRANS. EPT 10 1 EA. BEST RIM CYL 1 EA. BEST MORT. CYL 1 EA. LCN CLOSER 1 EA. LCN CLOSER 2 EA. G/J OH STOP 2 EA. ROCK KICK PLATES 2 EA. ROCK MOP PLATES 1 EA. 1 EA. 2 EA. 1 EA. PEMKO THRESHOLD PEMKO DOOR SEALS PEMKO DOOR SEALS VON POWER SUPPLY 12E71 RP 1E74 C4 RP3 4111 EDA LH 84" 4111 EDA RH 104S K1050 B4E 10 K1050 B4E 6 NiiiR 2 5 2O {34F3d7 ' i'e f;1 f6Gcs 272A72 FHSL 14 S88D21 S88D7 PS -914 X 900-4RL bu-oos& RHR/ACTIVE NON -RATED 652 630 630 PRIMED SP28 626 626 689 689 630 630 630 ALUM D. BRN D. BRN RECEIVED CITY OF TUKWILA MAR 04 2016 PERMIT CENTER 4409 South Orchard Street • Tacoma, WA 98466. Phone (253) 471-9150 • Fax (253) 471-9171 Contract Dept. Fax (253) 475-3513 • www.wah-usa.com WAH 103/06/01 Fig PROJECT: CONTRACTOR: SUPPLIER: DATE: WAs1II*OTO/4 £SCHITRCTURAL HARDWARE CO. DOOR HARDWARE THORNDYKE ELEMENTARY SCHOOL 4415 S. 150TH ST TUKWILA, WA. 98188 206- 901- 7600 F206- 901- 7603 FORMA CONSTRUCTION 2823 29TH AVENUE SW TUMWATER, WA. 98512 360-754-5788 F360-943-5868 f,,c 2 i l '..7.17.1:-.\'',/..' �r n P Pf7nrr� II ij _ tt-%L �,h WASHINGTON ARCHITECTURAL HARDWARE 4409 S. ORCHARD ST. TACOMA, WA 98466 253 471-9150 F253- 471-9171 PM, RUSSELL SHAWVER JAN. 18 2016 bt oos& RECEIVED CITY OF TUKWILA MAR 04 2016 PERMIT CENTER 4409 South Orchard Street • Tacoma, WA 98466• Phone (253) 471-9150 • Fax (253) 471-9171 Contract Dept. Fax (253) 475-3513 • www.wah-usa.com WAH103/06/0I Flt WASHINGTON ARCHITECTURAL HARDWARE CO. 4409 South Orchard St. Tacoma, WA 98466 Phone: (253) 471-9150 Fax: (253) 471-9171 TERMS AND CONDITIONS_ 1. Only schedules that are marked "APPROVED" or "FOR FILE & FIELD USE" are authorized for use by other trades and for installation. 2. No material will be ordered until the schedule has been approved by the proper authority. 3. Approval of this schedule constitutes an agreement between the contractor and/or architect and Washington Architectural Hardware Co. that all items listed are correct or "correct as noted". 4. Orders placed with our suppliers cannot be canceled, changed, or delayed, except with supplier approval and upon terms that will indemnify Washington Architectural Hardware Co., against loss. 5. Because the material for this job is special in nature and in most cases, ordered specifically for this project, it may not be returnable or may be subject to a restocking charge. Please contact your project manager to obtain a Return Goods Authorization BEFORE returning anything. NO RETURNS WILL BE ACCEPTED WITHOUT AN RGA. 6. Once a delivery date is agreed upon and material has been ordered, the date cannot be changed unless satisfactory to all parties concerned. All material supplied by Washington Architectural Hardware Co. is quoted full freight allowed jobsite or freight forwarder and our responsibility ends when the freight company accepts the shipment. If there is any shortage and/or damage, it is the responsibility of the consignee to make the claim. 7. Washington Architectural Hardware Co. cannot be held responsible for delays caused by strikes, acts of God or other conditions beyond our control. 8. Washington Architectural Hardware Co. will replace defective material within the manufacturer's warranty period. However, Washington Architectural Hardware Co. will not be responsible for damages, delays or expenses incurred by other trades or users of our product. 9. Failure to follow manufacturers installation and adjustment instructions may void the manufacturer's warranty. 10. If materials are required, on site, prior to Washington Architectural Hardware Co. receiving schedule and/or shop drawing approval: the contractor will be doing so at their own risk and releasing Washington Architectural Hardware Co. from any responsibility. In the event revisions to the schedule do affect material already delivered, it will be the contractors responsibility either to use the delivered materials or pay for any replacement. Washington Architectural Hardware Co. will require a signed change order or field work order before replacement materials can be provided. :I and Submittal Notes Job Name: Thorndyke ES Storefront TI Job Number: NA Date: 1/18/2016 1) The specified exits require a 4 7/8" stile. Verify that works on the storefront doors. 2) The specified mullion is steel and will need to be painted. Verify this is correct for the storefront system. 3) The PA mount closers need a minimum of 7" on the door header or they may require special template mounting plates or brackets. 4) Verify the handing on the active door leaf. J143/O8/13 THORNDYKE ELEMENTARY SCHOOL FINISH HARDWARE TUKWILA, WA PART 1 GENERAL 1.1 SUMMARY A. SECTION 087100 Section Includes: 1. Complete Finish Hardware for the Project in accordance with drawings, specifications and schedules. 2. Items not specifically mentioned but required to complete the work. 3. Wiring diagrams for electric hardware furnish under this section. B. Related Documents: 1. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 1 Specification Sections apply to this ection. 2. Section 01 10 00 School Dude Maintenance Management S 3. Division 08 Section Hollow Metal Doors and Frames 4. Division 08 Section Wood Doors 5. Division 08 Aluminum Doors and Frames 6. Division 26 Electrical 7. Division 28 Electronic Safety and Security 1.2 REFERENCES: steMEVIEWED FOR CODE COMPLIANCE APPROVED MAR 2 5 2016 A. ANSI - American National Standards Institute. City of Tukwila 1. ANSI 156.18 — Materials and Finishes. !mein 2. ANSI A117.1 — Specifications for making buildings and faci ti�sAs l'ti l�iysi cal Div handicapped people. B. BHMA — Builders Hardware Manufacturers Association C. DHI — Door and Hardware Institute D. NFPA — National Fire Protection Association 1. NFPA 80 — Fire Doors and Windows 2. NFPA 101 — Life Safety Code 3. NFPA 105 — Smoke and Draft Control Door Assemblies 4. NFPA 252 — Fire Tests of Door Assemblies 1.3 SUBMITTALS RECEIVED CITY OF TUKWILA MAR 0 4 2016 PERMIT CENTER A. Product Data: 1. Submit six copies of schedule per Division 1. 2. Organize vertically formatted schedule into "Hardware Sets" with index of doors and headings, indicating complete designations of every item required for each door or opening. 3. Include following information: a. Type, style, function, size, quantity and finish of hardware items. b. Use BHMA Finish codes per ANSI A156.18. c. Name, part number and manufacturer of each item. d. Fastenings and other pertinent information. e. Location of hardware set coordinated with floor plans and door schedule. f. Explanation of abbreviations, symbols, and codes contained in schedule. g. Mounting locations for hardware. h. Door and frame sizes, materials and degrees of swing. i. Catalog cuts. j. Make substitution requests in accordance with Division 1. 1) Include product data and indicate benefit to the Project. 2) Furnish operating samples on request. FINISH HARDWARE b (0.- coos 6. 087100 - 1 �Iz • THORNDYKE ELEMENTARY SCHOOL FINISH HARDWARE TUKWILA, WA SECTION 087100 k. Furnish as-built/as-installed schedule with closeout documents, including keying schedule, wiring/riser diagrams, manufacturers' installation, adjustment and maintenance information, and supplier's final inspection report. 1.4 QUALITY ASSURANCE: A. Qualifications: 1. Hardware supplier; a direct factory contract supplier who employs a certified architectural hardware consultant (AHC) who is: a. available at reasonable times during course Work for project hardware consultation to Owner, Architect and Contractor. b. responsible for detailing, scheduling and ordering of finish hardware. B. Hardware: 1. Provide new, free of defects, blemishes and excessive play. 2. Obtain each kind of hardware (latch and locksets, exit devices, hinges and closers) from one manufacturer. C. Exit Doors: 1. Make operable from inside with single motion without the use of a key or special knowledge or effort. D. Pre -Installation Meetings: 1. Initiate and conduct with supplier, installer and related trades, coordinate materials and techniques, and sequence complex hardware items and systems installation. 2. Convene at least one week prior to commencement of related work. 1.5 DELIVERY, STORAGE AND HANDLING: A. Delivery: 1. Coordinate delivery to appropriate locations (shop or field). 2. Secure delivery of permanent keys and cores to Owner's representative. B. Site Acceptance: 1. Deliver items individually packaged in manufacturers' original containers, complete with proper fasteners and related pieces. 2. Clearly mark packages to indicate contents, locations in hardware schedule and door numbers. C. Storage: 1. Provide locked storage area for hardware, protect from moisture, sunlight, paint, chemicals, etc. 1.6 PROJECT CONDITIONS: A. Where exact types of hardware specified are not adaptable to finished shape or size of members requiring hardware, provide suitable types having as nearly as practical as the same operation and quality as type specified, subject to Architect's approval. 1.7 SEQUENCING: A. Furnish manufacturer templates to door and frame fabricators. B. Use hardware consultant to check Shop Drawings for doors and entrances to confirm that adequate provisions will be made for proper hardware installation. 1. Confirm that door manufacturers furnish necessary UBC -7-2 compliant seal packages. 1.8 WARRANTY: A. Furnish warranty as part of respective manufacturers' regular terms of sale. B. Provide manufacturers' warranties as follows: 1. Closers: Twenty-five years mechanical, two years electrical. FINISH HARDWARE 087100 - 2 THORNDYKE ELEMENTARY SCHOOL FINISH HARDWARE TUKWILA, WA SECTION 087100 2. Hinges: Life of Building. 3. Locksets 3 years 4. Exit Devices 3 years mechanical, 2 years electrical 5. Other Hardware: Two years. C. Provide to the Owner/GC factory order numbers for hardware warranty purposes. 1.9 COMMISSIONING: A. Test door hardware operation with climate control system and stairwell pressurization system both at rest and while in full operation. PART 2 PRODUCTS 2.1 MANUFACTURERS: A. Comply with list of acceptable and alternate manufacturers. B. Submit for review products with equivalent function and 1. ITEM: (ABRV) MANUFACTURER: a. Hinges (MCK) McKinney b. Electrified Hinges (MCK) McKinney b. Locks (BES) Best c. Cylinders (BES) Best d. Closers (LCN) LCN e. Silencers (ROC) Rockwood f. Kick Plates (ROC) Rockwood h. Wall Stops (ROC) Rockwood i. Overhead Stops (GLY) Glynn -Johnson j. Thresholds (PEM) Pemko k. Seals & Bottoms (PEM) Pemko I. Exit Devices (VON) Von Duprin M. Power Supply (VON) Von Duprin N. Auto Operator (REC) Record O. Actuators (BEA) BEA Security features of scheduled products below: ACCEPTABLE SUB: Stanley, Ives, Hager Stanley, Ives, Hager None None None Ives, Hager, Trimco Ives, Hager, Trimco Ives, Hager, Trimco Rixson National Guard National Guard None None None None C. Provide hardware items required to complete the work in accordance with these specifications and manufacturers' instructions. 1. Include items inadvertently omitted from this specification and note these items in submittal for review. 2. Where scheduled item is now obsolete, bid and furnish manufacturers updated item at no additional cost to the project. 2.2 HANGING MEANS: A. Conventional Hinges: 1. Hinge open widths minimum but of sufficient throw to permit maximum door swing. 2. Provide steel or stainless steel pins and ball bearings. 3. Three hinges per leaf to 7 foot, 6 inch height. Add one for each additional 30 inches in height, or any fraction thereof. 4. On doors over 36" in width, provide 5" hinges. 5. All out -swinging doors: Non Removable (NRP) pins. 6. Non-ferrous material exteriors and at doors subject to corrosive atmospheric conditions. 7. Shims and shimming instructions for proper door adjustment. 2.3 LOCKING A. Manufacturers: FINISH HARDWARE 087100 - 3 THORNDYKE ELEMENTARY SCHOOL FINISH HARDWARE TUKWILA, WA SECTION 087100 1. Best — Owner's Standard B. Latches and Locks for Means of Egress Doors: Comply with NFPA 101. Doors shall not exceed 15 lbs (67 N) to release the latch. Locks shall not require the use of a key, tool, or special knowledge for operation from the egress side. C. Function numbers as listed in sets. D. BEST heavy duty cylindrical type: 1. Locksets and Latchsets: To ANSI A156.2, Series 4000, Grade 1, UL listed, extra heavy-duty cylindrical type. 2. Backset 2 3/4 inches (70 mm). 3. Interchangeable Core: Keyway as requested by Owner. 4. Locksets to have anti -rotational studs that are through -bolted. 5. Keyed lever with no exposed keeper hole. 6. Each lever to have independent spring mechanism designed to control lever only. 7. Outside lever sleeve seamless, 1 -piece construction, hardened steel alloy. 8. Keyed Lever: Removable only after core is removed, by authorized control key, to allow access to knob keeper. 9. Hub, side plate, anti -rotational studs 1 -piece casting with shrouded locking lug. 10. Permanent core face same finish as lockset finish. 11. Latch bolts shall be minimum 9/16" throw, deadlocking on keyed and exterior functions. E. Strikes: 1. Provide strikes with extended lips where required to protect trim from being marred by latch bolt. Provide strike lips that do not project more than 1/8" beyond doorframe trim at single doors and have 7/8" lip to center at pairs of 13/4" doors. Provide wrought box strikes on all locks. F. Hardware supplier shall verify all lock functions with Owner prior to ordering material. 2.4 EXIT DEVICES/PANIC HARDWARE A. Von Duprin: [98 series] 1. Independent lab -tested 1,000,000 cycles. 2. Push -through touch pad design. No exposed touch bar fasteners, no exposed cavities when operated. Return stroke fluid dampeners and rubber bottoming dampeners, plus anti -rattle devices. 3. '/<" throw deadlocking latchbolts. 4. No exposed screws to show through glass doors. 5. Non -handed basic device design with center case interchangeable with all functions, no extra parts required to effect change of function. 6. Releasable with 32 Ib. maximum pressure under 250 Ib. load to the door. 7. Lever Trim: Breakaway type, forged brass or bronze escutcheon min .130" thickness, match lockset lever design. 8. Fire -Labeled Devices: UL label indicating "Fire Exit Hardware". Vertical rod devices less bottom rod (LBR) unless otherwise scheduled. 9. Removable Mullions: Removable with single turn of building key. Securely reinstalled without need for key. Furnish storage brackets for securely stowing the mullion away from the door when removed. 2.5 CLOSERS FINISH HARDWARE 087100 - 4 THORNDYKE ELEMENTARY SCHOOL FINISH HARDWARE TUKWILA, WA SECTION 087100 A. LCN: [4000] Surface Closers 1. Full rack-and-pinion type cylinder with removable non-ferrous cover and cast iron body. Double heat-treated pinion shaft, single piece forged piston, chrome -silicon steel spring. 2. ISO 2000 certified. Units stamped with date -of -manufacture code. 3. Independent lab -tested 8,000,000 cycles. 4. Thru-bolts at wood doors unless doors are provided with closer blocking. 5. Non -sized, non -handed, and adjustable. Place closer inside building, stairs, and rooms. 6. Plates, brackets and special templating when needed for interface with particular header, door and wall conditions and neighboring hardware. 7. Opening pressure: Exterior doors 8.5 Ib., interior doors 5 Ib., labeled fire doors 15 Ib. Separate adjusting valves for closing speed, latching speed and backcheck, fourth valve for delayed action where scheduled. 8. Extra -duty arms (EDA) at exterior doors scheduled with parallel arm units. 9. Exterior door closers: tested to 100 hours of ASTM B117 salt spray test, furnish data on request. 10. Exterior doors do not require seasonal adjustments in temperatures from 120 degrees F to —30 degrees F, furnish data on request. 11. Non -flaming fluid will not fuel door or floor covering fires. 2.6 OTHER HARDWARE A. Overhead Stops: 1. Glynn -Johnson Series 100 a. Stainless steel. b. Non -plastic mechanisms and finished metal end caps. c. Field -changeable hold -open, friction and stop -only functions. B. Kick Plates: 1. .Four beveled edges, .050 inches minimum thickness, height and width as follows: At kick plates: 10" x 2" LDW At armor plates: 34" x 2" LDW At mop plates: 4" x 1 "LDW at pull side, and 2" LDW at push side. 2.. Sheet -metal screws of stainless steel. 3. Adjust width of kick, mop and armor plates to avoid interference with hardware, including but not limited to vertical rods, surface bolts, kick -down or plunger holders, etc. C. Door Stops: 1. Provide stops to protect walls, casework or other hardware. a. Unless otherwise noted in Hardware Sets, provide wall type with appropriate fasteners. b. Where wall type cannot be used, provide floor type. c. If neither can be used, provide overhead type. D. Thresholds: 1. Provide as scheduled and per details. 2. Proposed substitutions: Submit for approval. a. Substitute products: Certify that the products equal or exceed specified material's thickness. E. Fasteners: 1. For typical exposed screws, use Phillips or Robertson drive. 2. For high security areas, use pinned TORX drive. 3. For flat head sleeve anchors (FHSL), allow slotted drive. 4. For sheet metal and wood screws, use full -thread. 5. For sleeve nuts, use full length to prevent door compression. F. All wire, junction boxes, conduit and the like shall be furnished and installed by the Division 16 contractor. The hardware supplier shall furnish complete elevation and point to point wiring FINISH HARDWARE 087100 - 5 THORNDYKE ELEMENTARY SCHOOL FINISH HARDWARE TUKWILA, WA SECTION 087100 diagrams to the Division 16 contractor, which shall include the number and size of required conductors. Installation of and connections to access control systems specified elsewhere are not included in this section. G. Silencers: 1. For interior hollow metal frames, provide 3 for single doors, 2 for pairs of doors. 2. Omit where adhesive mounted seal occurs. 3. Leave no unfilled/uncovered pre -punched silencer holes. 2.7 AUTOMATIC OPERATORS: A. Record 8100 Series: 1. Provide units which conform to the requirements of the Americans with Disabilities Act of 1990 (ADA) and as required by local jurisdiction. 2. See hardware groups for scheduled finish. 3. Automatic operators must be installed by a factory authorized and trained installer. FAILURE TO USE AN AUTHORIZED INSTALLER SHALL VOID THE WARRANTY. Below are three local factory authorized installers. a. Western Entrance Technologies — (360) 863-9382 Steve Wilson b. Commercial Hardware Services — (206) 948-8475 Tom Holt c. C4 Products — (253) 840-1738 Dave Trotter 2.8 FINISH: A. Door Hardware: 1. Finishes in general to be Dull Chrome (626), Stainless Steel (630) Clear Anodized Aluminum (628, Sprayed Aluminum (689) 2. See hardware groups for scheduled finish. B. Door Closers: 1. Factory powder coated to match other hardware, unless otherwise noted. 2.9 KEYING REQUIREMENTS: A. Manufacturers: 10. Best G. Keying schedule: The supplier's Factory Authorized Service Center shall meet with the Owner to finalize keying requirements and obtain keying instructions in writing. All cylinders shall be keyed by Service Center, combinated in sets or subsets, master keyed or great grandmaster keyed, as directed by Owner. H. Cylinders: 1. Manufacturer's standard Interchangeable core type, constructed from brass or bronze, stainless steel, or nickel silver. 2. Number of Pins: Seven. 3. Mortise Type: Threaded cylinders with required cam and trim ring(s). 4. Rim Type: Cylinders with back plate, flat -type vertical or horizontal tailpiece, and raised trim ring. 5. Bored -Lock Type: Cylinders with tailpieces to suit locks. I. Permanent Cores: Manufacturer's standard; finish face to match lockset; interchangeable cores. J. Construction Cores: Provide construction cores that are replaceable by permanent cores. 1. The Owner or Owner's Security Agent in conjunction with the service center shall remove construction cores and install final cores. FINISH HARDWARE 087100 - 6 THORNDYKE ELEMENTARY SCHOOL FINISH HARDWARE TUKWILA, WA SECTION 087100 K. Keying System: Both the cylinders and key blanks shall be protected from unauthorized manufacture and distribution by the manufacturer's United States patents. L. Key System: Match Owner's existing "Best" interchangeable core system throughout. Key blanks available only from factory -direct sources, not available from after -market key blank manufacturers. M. Keys: Provide nickel -silver keys permanently inscribed with a visual key control number and "DO NOT DUPLICATE" notation. Furnish keys in the following quantities: 1. Cylinder Change Keys: Two. 2. Master Keys: Six. 3. Grand Master Keys: None. 4. Temporary construction keys: Ten. 5. Construction control keys: Two. N. Deliver all permanent keys, security cores, and other security keys directly to the owner. Hardware supplier to set up Key Cabinet complete to be delivered as directed by School. PART 3 EXECUTION 3.1 ACCEPTABLE INSTALLERS: A. Installer: Factory trained, certified, and carries a factory -issued card certifying that person as a "Certified Installer". B. Substitute Installer: Use installer that can demonstrate suitably equivalent competence and experience. 3.2 PREPARATION: A. Ensure that walls and frames are square and plumb before hardware installation. B. Locate hardware per SDI -100 and applicable building, fire, life -safety, accessibility, and security codes. 1. Notify Architect of any code conflicts before ordering material. 2. Where new hardware is to be installed near existing doors/hardware scheduled to remain, match locations of existing hardware. 3.3 INSTALLATION A. Install hardware per manufacturer's instructions and recommendations. Do not install surface - mounted items until finishes have been completed on substrate. Set units level, plumb and true to line and location. Adjust and reinforce attachment substrate for proper installation and operation. B. Do not install surface -mounted items until finishes have been completed on substrate. C. Set units level, plumb and true to line and location. D. Adjust and reinforce attachment substrate for proper installation and operation. 1. Install jamb -applied gaskets before closers, overhead stops, rim strikes, etc. Install sweeps across bottoms of doors before astragals, cope sweeps around bottom pivots, trim astragals to tops of sweeps. 2. When hardware is to be attached to existing metal surface and insufficient reinforcement exists, use RivNuts, NutSerts or similar anchoring device for screws. 3. Locate floor stops not more than 4 inches from the wall. 4. Drill pilot holes for fasteners in wood doors and/or frames. 3.4 ADJUSTING A. Adjust and check for proper operation and function. B. Replace units, which cannot be adjusted to operate freely and smoothly. FINISH HARDWARE 087100 - 7 THORNDYKE ELEMENTARY SCHOOL FINISH HARDWARE TUKWILA, WA SECTION 087100 1. Repair or replace hardware damaged by improper installation or adjustment methods to Owner's satisfaction. 2. For inspection, use hardware supplier; include suppliers with closeout documents. 3. For follow-up inspection, provide letter of agreement to Owner that approximately 6 months after substantial completion, installer will visit Project with representatives of the manufacturers of the locking devices and door closers to accomplish following: a. Re -adjust hardware. b. Evaluate maintenance procedures and recommend changes or additions, and instruct Owner's personnel. c. Identify items that have deteriorated or failed. d. Submit written report identifying problems and likely future problems. 3.5 PROTECTION/CLEANING: A. Cover installed hardware, protect from paint, cleaning agents, weathering, carts/barrows, etc. 1. Remove covering materials and clean hardware just prior to substantial completion. B. Clean adjacent wall, frame and door surfaces soiled from installation/reinstallation process. 3.6 SCHEDULE OF FINISH HARDWARE A. See door schedule in drawings for Hardware Set (group) assignments. HW SET: 01 Door 101A 6 EA 2 EA 1 EA 1 EA 1 EA 2 EA 1 EA 1 EA 2 EA 2 EA 2 EA 1 EA 1 SET 1 SET 1 EA 2 EA HINGE POWER TRANSFER MULLION PANIC HARDWARE PANIC HARDWARE RIM CYLINDER AUTO OPERATOR SURFACE CLOSER OVERHEAD STOP KICK PLATE MOP PLATE THRESHOLD MULLION SEAL GASKETING POWER SUPPLY ACTUATORS CARD READER DOOR CONTACT END OF SECTION 087100 T4A3786 NRP 4.5" x 4.5" EPT-10 KR4954 7'0" RX-EL98NL x 990NL-RN RX-EL98DT x 990DT 12E 72 S2 RP 8100 PUSH SIDE 4111 EDA 100S K1050 B4E K1050 B4E PER DETAIL S88D (2 ROWS) S88D x HEAD & JAMBS PS914 x 900-4RL 10PBS61 x 10BOX6SQFM BY ACCESS CONTROL BY SECURITY CONTRACTOR 652 MCK 689 VON 689 VON 630 VON 630 VON 626 BES 689 REC 689 LCN 630 GLY 630 ROC 630 ROC AL PEM DKB PEM DKB PEM VON BEA B/O B/O FINISH HARDWARE 087100 - 8 Security Solutions REVIEWED FOR CODE COMPLIANCE APPROVED MAR 2 5 2016 1, " City of Tukwila BUILDING DIVISivN C c -r FIL3 CI E�WILA MIf�� N C W 0 z_ J U OOS\t9 MORTISE AND RIM CYLINDERS . ACCESS SYSTEMS TABLE OF CONTENTS Page Page 1E Series features 2 Eurocylinders 7 1E Series specs/how to order 2 Cylinders and cams 8 1E Series rings/spindles/mortise/service equipment 3 1E Cylinder special rings 9 1E Series special cylinders 4, 5 5E Series specs/accessories 10 1 EJ7J4/1EK7K4 high security cylinders 6 5E Series how to order 11 Patented keying system 6 1E Series how to order (continued) 12 1E SERIES — FEATURES 1E Mortise Cylinder Standard mortise applications require use of BEST's 1E series cylinders with standard 1E -C4 cam. BEST cylinders may be altered to function with other manufacturers' locks by use of different cams (see page 8) and different cylinder rings (see page 9). Special cylinder variations are available for most applications (see pages 4 & 5). BEST cylinders are machined from brass or bronze bar stock and are available in a variety of finishes. Additional security is provided by a set screw that mounts diagonally in the cylinder wall and when tightened, holds the cylinder securely in the housing. BEST mortise cylinders feature the BEST interchangeable core and may be master -keyed into any existing BEST system. Contact your local Stanley Security Solutions sales office tor information on special cylinder applications not listed in this catalog. — "A„ Specifications Cylinder Dimension Nomenclature "A" eiti 1E Cylinder diameter– 1 %2" To order: example: 1E74-C4-RP3-626 Products covered by on or more of the following patents: 5,590,555 5,794,472 12E Rim Cylinder Standard rim cylinder applications require the use of BEST's 1E rim cylinder series. BEST rim cylinders are interchangeable with other manufacturers' rim cylinders. BEST rim cylinders are machined from solid bar stock and are available in a variety of finishes. The standard package for the BEST rim cylinder includes cylinder, RP3 ring package, 1 E -S2 spindle, clamp plate and clamp plate screws. BEST rim cylinders feature the BEST interchangeable core and may be masterkeyed into any existing Best system. Specifications Cylinder Dimension Nomenclature "A" 12E62 12E72 1 3tou 11'/2" Door Thickness 1"to2%" 1 '/A" to 3" Cylinder d iameter-1 %2" To order: example: 12E72-S2-RP3-626 1E SERIES HOW TO ORDER 1E Series 7 Core Housing 4 Function Code Length Code C4 Cam or Spindle RP3 Rings 626 Finish ** I See p. 12 0–dummy 6 -6 -pin 7-7 pin housing accepts all Best cores See p. 12 Blank– Standard 22-13/ a" 24-1'/2" up to6" (See page 4-5) (See code below) C4– Standard cam C181–Adams Rite MS cam S2–Standard spindle (For special cams see page 8) RP– Rim cylinder RP1–Tapered cylinder RP2-6 pin mortise RP3-7 pin mortise RP4-3E mortise (For special rings see page 9) 626 690 Satin* 606 612 613 619 Bright* 605 611 625 *Indicates extra cost " Must specify keymark and number of keys or designate L/C for less core. srnraer 00,1 3=Si C)TI E Installation Methods Door Mounting Hardware Mounting templates for all series holders show various types of hinging methods as well as various degrees of opening. To accommodate the overhead stop to the various mounting methods requires a simple shifting of dimensions A and B. To be assured that reinforcement and mortising are in the proper location, be sure to secure the proper templates from your Glynn -Johnson dealer. These templates include all necessary information for reinforcing door and frame, complete installation instructions for the various mounting methods and the degree of opening required. Concealed Concealed overhead door holder installation requires that the jamb bracket be mortised flush with the bottom of the jamb. The arm and channel must be mortised into the door so the arm is flush with top of the door. A cutout made for the arm on the stop side of single acting doors as in the sketch. Double acting doors require a cutout for the arm on both sides of the door as shown in the sketch. Hollow metal doors must be reinforced at the top of the door to provide necessary strength for the channel. Hollow metal frames must be reinforced in the jamb to provide strength for the jamb bracket. Strength of wood frame and door must be adequate for the holder specified. Accurate template drawings for each holder give complete reinforcement and mortising specifications. They are readily available from your Glynn -Johnson representative. Surface Type Surface mounted overhead door holder installation does not require mortising of jamb or door. The jamb bracket is surface mounted on the stop of the frame. The channel is also surface mounted on the face of the door. Hollow metal doors and jambs must be reinforced to provide necessary strength for the holder specified. Strength of wood doors and jambs must also be adequate for the holder. A typical surface mounted installation is shown in Figure 1 where jamb bracket is fastened to the stop. Angle jamb brackets are available for hinge side mounting (Figure 2) and for use with rabbeted doors or flush transom installations (Figure 3). Jamb brackets with special shims for use on jambs with blade stops arc also available (Figure 4). Advise stop height and the appropriate shim kit will be provided. ,I 1•I BUTT 1.0 r A C #s: q:rSET PnOT RFINFORCE 14011.0WD M[TAL JANu . JAW URACKUI µCMOUTLDER OUT FARMOR 0 FIGURE 20 DOUBLE ACTING DOOR FIGURE 10 TYPICAL INSTALLATION FIGURE 20 HINGE SIDE APPLICATION FIGURE 30 ANGLE JAMB BRACKETO FOR FLUSH TRANSOM ORD RABBETED DOORS FIGURE 40 JAMB BRACKET SHIM] FOR BLADE STOP DOORS GLYNN-JOHNSON. 5 100 Series Concealed Overhead Door Holders/Stops 100 Series Heavy -Duty Glynn -Johnson offers a complete line of overhead door holders and stops, accommodating virtually all openings with solutions for even the most complex door control problems. These concealed holders and stops provide the most attractive and reliable heavy-duty door control available. Glynn -Johnson 100 series holders and stops provide the most reli- able and versatile concealed overhead door control. They are designed for installation on virtually all types of doors mounted on conventional type butt hinges, pivots, continuous hinges, swing clear hinges and numerous other specialty hinges. When used in conjunction with many surface -applied door closers, 100 series holders and stops provide the most effective control for entrance doors and vestibule doors of all types, as well as heavy or often used interior doors. Templates provided allow for variable mounting positions, ranging from 85° - 110° of opening. Five Models: • 100H Series Hold -Open Model • 1001 -IP Series Internal Hold -Open Model • 100F Series Friction Hold -Open Model • 100S Series Stop -Only Model • 100SE Series Special Stop -Only Model Six Sizes: • Each model comes in six sizes. • Simple • Standardized Three Options: • ADJ—Adjustable Jamb Bracket • CJ—Jamb Bracket for use with LCN5030 Closer • SOC—Pin-in-Socket Security Screw Package Unmatched Convenience: • Non -handed • Improved Compatibility with Door Closers • Single/Double-Acting Doors • Interior/Exterior Applications • Reduced Door Prep • Durable • Improved Corrosion Resistance • Function Conversion Kits are Available. 18 GLYNN-JOHNSON Materials and Finishes: In Heavy Gauge Brass or 300 Series Stainless Steel, these models offer the broadest range of finishes in the industry, complementing any design and offering the highest resistance to corrosion. Available in the following finishes: Finishes US3 US4 US 10 USIOB US32 US32D SP4 SP10 SP28 SP313 SPBLK Models Description Polished Brass Satin Brass Satin Bronze Oil Rubbed Bronze Polished Stainless Steel Satin Stainless Steel Powder Coat Brass Powder Coat Bronze Powder Coat Aluminum Powder Coat Dark Bronze Powder Coat Black These models provide a wide range of optional features, and are ideal for use on entrance and vestibule doors, large doors, doors opened frequently, or doors subject to abuse. These models are also furnished with an offset -style jamb bracket. Designed for heavy-duty applications, 100 series models will provide long-lasting protection to doors, frames, hinges, related hardware and surrounding walls or obstructions. 100H Series Hold -Open (Suffix H) The Hold -Open function should be used where it is desired to hold a door open at a predetermined position for short or long periods of time, permitting an unobstructed traffic flow through the opening. These models are both selective and adjustable, featuring the most reliable Hold -Open mechanism available. They feature a control knob which protrudes from the face of the door and turns the Hold -Open function on or off. Set in the inactive position, the unit acts as a stop and shock absorber. The tension on the Hold -Open mechanism can be adjusted using an alien wrench to offset air currents or other exterior conditions. The Hold -Open tension adjustment is located in the bottom of the track in the top of the door. 100HP Series Internal Hold -Open These models provide a Hold -Open unit with the Hold -Open mechanism built into the channel, thus reducing the door prep. The 100HP have a preset Hold -Open force that is not adjustable. The Hold -Open feature is not selectable in these units, so the doors are always held open. 100F Series Friction Hold -Open (Suffix F) Friction Hold -Open models provide an alternative holding method, ideal for heavy patient room doors, closet doors or similar applications where multiple Hold -Open positions are desired. The friction tension is adjusted using an alien wrench and an open end wrench. The friction tension adjustment is located on the top of the slider in the channel. (Suffix S) When the Hold -Open function is not required, the Stop -Only function provides the same effective door control minus the Hold -Open feature. The Stop -Only model may be used on fire doors. 00S Series Stop -Only 100SE Series Special Stop -Only (Suffix SE) When Stop -Only models are used in conjunction with single point Hold -Open electronic door closers, they may be ordered without the shock -absorbing mechanism. Used as an auxiliary stop with these closers, they will prolong the life of the closer. The stop location is adjusted using an alien wrench on the stop block located in the channel. Note: Caution should be used when using this option in other applications, as the elimination of the shock -absorbing spring can put added stress on door and frame if used improperly. Application Information UL Classification The 100 series Stop -Only models are classified by Underwriters Laboratories (UL) as Miscellaneous Fire Door Accessories. This classification applies to use on either Hollow Metal Fire Doors or Wood Fire Doors. Where Wood Door manufacturer's listing allows for the cutout required for installation, concealed overhead stops may be used on those wood fire doors. These units may be used on doors of any rating. As a reminder, the Miscellaneous Fire Door Accessories (GVUX) section is defined by UL as: "Miscellaneous fire door accessories are intended in the individual Listings. The accessories have been investigated to determine that when installed in accordance with the manufacturer's instructions, the accessories do not adversely affect the fire rating of the fire door and/or fire door frames." Dead Stop Templating: If a wall or similar obstruction is in place at 110° or less opening angle (i.e. doors that open back-to-back), Dead Stop Templating should be used. This includes all Hold -Open, Friction and Stop -Only models, except when the "SE" Option is used. The Dead Stop position is reached when the shock -absorbing spring is fully compressed, the initial degree of opening will be 5° to 7° less than the Dead Stop opening. Example: if the holder is templated to 100° Dead Stop, the door will hold open somewhere between 93° and 95,° but no further than 100°. Note: Do not use dead -stop templating on the 100SE Series since there is no shock -absorbing spring. Environmental Considerations: Environmental factors should always be considered when specifying overhead holders and stops. Doors that are positioned on a building's exterior or subject to corrosive conditions should be equipped with a holder constructed primarily of stainless steel or brass materials. For interior applications, steel is acceptable, though brass substrates generally provide a more attractive architectural -grade finish. Options Suffix ADJ (Adjustable Jamb Bracket): An additional option on the 100 series is the adjustable jamb bracket, which allows the degree of Hold -Open or Stop angle to be adjusted after installation. Suffix "ADJ" is available in all functions, but only in sizes 3, 4, 5 & 6. ADJ jamb bracket requires additional frame prep. The ADJ option cannot be added to an existing unit, it must be factory ordered. Suffix CJ (Closer Jamb Bracket): Provides a special jamb bracket needed for 100 series units used with LCN5030 closers. These special jamb brackets are handed, so handing will need to be specified when ordering the "CJ" option, CJLH for a left hand door and CJRH for a right hand door. The CJ option cannot be added to an existing unit, it must be factory ordered. Suffix SOC (Pin -in -Socket Security Screw Package): A screw package with pin -in -socket screws for mounting the jamb bracket to the frame is provided instead of the standard screw package. GLYNN-JOHNSON 19 100 Series Concealed Overhead Door Holders/Stops FRICTION ADJUSTMENT — 1' _1 1 /4' 3-12' STANDARD JAMB BRACKET 1-1/4' 23�t4'—► -'I 12.I- FRAME REIN1FORCEMENT J ARM CUTOUT 4 1/4t — ARM CUTOUT BOTH SIDE ONE SIDE .-i•1Nr DOUBLE ACTING 000RS 4-1/4' —►^ •Onfa tOCK loo SEA. SINGLE ACTING ACTING 000RS 4 i 314' '"-----' 3+8' DRILL FOR CONTROL KNOB. I. OMIT LOCK MECHANISM MORTISE AND CONTROL KNOB HOLE IF FRICTION, �— 5-12'--s STOP ONLY OR AUTOMATIC HOLD OPEN VERSIONS ARE USED. FRONT ELEVATION 17 1.11114' 0 '1 1 .--r 3I8' J_ OPTIONAL JAMB BRACKET "ADJ" 0 0 Note: This chart illustrates the most common types of hinging and door opening sizes. For unusual door details, contact Glynn -Johnson for availability `These sizes are not available for use with offset pivots. Also not available with the ADJ option, The template information on this page is for reference only and is not intended to serve as an installation template. For complete dimensional information, refer to Glynn -Johnson template book. 20 GLYNN-JOHNSON BHMA/ANSI, A156.8 & FED. Spec. Cross Reference G -J Model BHMA* FED. Spec. 100 Series Sizing Chart C01511 1160 101-106 S BUTTS/OFFSET PIVOTS ---- 101-106 F CENTER HUNG SIZE DOOR OPENING STOP ONLY HOLD OPEN FRICTION DOOR OPENING STOP ONLY HOLD OPEN FRICTION I 1 18"-23' 101S* 101H* 101F" — •-- ---- - 2 23-1/16"-27" 102S' 102H" 102F" —__ __ __ ....... ____.. -- 3 4 27-1116"-33' 103S 103H 103F 33-1/16"-39' 103S 1031-1 103F 33-1/16'-39" 104S 104H 104F 39-1/16"-45' 104S 1041-1 104F 5 39-1/16'5' 105S 105H 105F 45.1/16'-51' 105S 105H 105F 6 45-1/16'-54' 106S 106H 106F 51-1/16"-59" 106S 106H 106F Note: This chart illustrates the most common types of hinging and door opening sizes. For unusual door details, contact Glynn -Johnson for availability `These sizes are not available for use with offset pivots. Also not available with the ADJ option, The template information on this page is for reference only and is not intended to serve as an installation template. For complete dimensional information, refer to Glynn -Johnson template book. 20 GLYNN-JOHNSON BHMA/ANSI, A156.8 & FED. Spec. Cross Reference G -J Model BHMA* FED. Spec. 101-106 H C01511 1160 101-106 S C01541 ---- 101-106 F C01531 — * First numeral (0) designates optional material. To specify Brass material, change 0 to 1 (i.e. C11511) Stainless Steel material, change 0 to 5 (i. e, C51511) BHMA All 100 series models are designed for heavy-duty applications and far exceed BHMA cycle test and force test requirements for Grade 1 holders and stops. Hetn! fc Ccdcz 10 Overhead Series: 10 Site (Door Opening Using Buns or Offset Pivots: 1 (18"-23") 2 (23-1/16"-27") 3 (27-1/16' —331 4 (33-1/16"-391 5 (39-1/16"-45") 6 (45-1/16"-54") Function: H Hold -Open HP Internal Hold -Open F Friction Hold -Open S Stop -Only SE Special Stop -Only H US26D — ADJ Finishes: US3 Polished Brass USA Satin Brass US10 Satin Bronze US10B Oil Rubbed Bronze US32 Polished Stainless Steel US32D Satin Stainless Steel SP4 Powder Coat Brass SP10 Powder Coat Bronze SP28 Powder Coat Aluminum SP313 Powder Coat Dark Bronze SPBLK Powder Coat Black Options: ADJ Adjustable Jamb Bracket CJLH Special Jamb Bracket for LCN 5030 Closer, LH Door CJRH Special Jamb Bracket for LCN 5030 Closer, RH Door SOC Pin -in -Socket Security Screws GLYNN-JOHNSON 21 4000 SERIES SURFACE MOUNTED CLOSERS PRODUCT SELECTION GUIDE Surface mounted 4000 Series LCN closers feature a modern design engineered for each application, easy installation, and superior performance. This guide is based on the desired mounting of the closer. EXTERIOR DOOR INTERIOR DOOR PUSH SIDE MOUNTED DOUBLE LEVER ARM 4020 4040XP 4110 4210* PUSH SIDE MOUNTED DOUBLE LEVER ARM 4020 4040XP 4110 4210* 4030 SINGLE LEVER ARM 41101 4040XP 4210T* * INDICATES HIGH SECURITY CLOSER. REFER TO THAT SECTION OF THE CATALOG. PRODUCT COMPARISON This chart shows a basic comparison of 4000 Series closers. Refer to the specific closer chapter for complete details. CLOSER SERIES 4010 4010T 4020 4020T 4030 40301 4040XP MOUNTING FINISH PULL SIDE MOUNTED DOUBLE LEVER ARM 4010 4040XP 4510* PULLSIDE MOUNTED E LEVER ARM 4020 4030 4040XP 4510* COVER SINGLE LEVER ARM 4000T 4010T 40201 45101* 4040XPT 40301 CYLINDER "ARM FUNCTION • • O O 0 0 0 0 0 • O • • 0 • • O O • • O • • 0 4040XPT • • O O 4110 O O O • 4110T O O O O 4000T • O O O • O • O • AVAILABLE O NOT AVAILABLE LCN, • • • • • • • • • • • • • • • • • • • • • 1 0 • • • • • O • • •. • • • • 0 0 0 0 0 • • • O O O O •• 1• • O 0 O O • • 44) 40 `Jy� y�JS ooJ� 140° 0 140° 140° 0 0 0 0 O 1800 120° O 0 0 O 100° 180° 0 140° 140° 0 0 0 0 O 180° 1000 O O O O O 180° 0 180° 0 110" 100° 100° 0 O 180° 180° O O O O O 1200 0 120° 0 180° 110° 110° 0 O 120° 110° O O 0 0 0 0 0 0 1800 180° 110° 110' 0 O 110° 100° O O 0 O O 0 80° 0 0 0 0 0 0 S Closer available with less than 5.0 lbs. opening force on 36"door. ** Maximum opening/hold-open point with standard template. See individual closer series for degrees of opening per installation. *** Advanced Variable Backcheck, **** Delay Action for 4040XP Requires standard 4041 cylinder. 1 PHONE 877-671-7011 FAX 800-248-1460 www.allegion.com/us 4/15 009426 40 SEIES SURFACE MOUNTED CLOSERS APPLICATIONS • For aluminum, hollow metal, or wood swinging doors and frames. • Can be used with hinge or pivot mounted door. ■ Adapter plates and other installation accessories available for unusual conditions. FEATURES COMMON TO 4000 SERIES • Each closer (except 4040XP, 4040XPT, 4030, 4030T) is designed for a specific mounting; hinge side, top jamb, or parallel arm. 4040XP closer with regular or hold -open arm mounts hinge side or top jamb, 4030 and 4040 regular parallel arm closers include 62PA SHOE required to parallel arm mount either regular or hold -open arm. ■ Handed for right or left swinging doors, except 4000T, 4030, 4030T, 4040XP and 4040XPT. ■ Closers to meet ADA reduced opening force requirements except 4000T. • Adjustable hydraulic backcheck cushions opening swing prior to 90°. • Separate regulation of general closing speed and latching speed. ■ Joints in regular arm and shoe adapt to uneven trim. ■ Reversible shoe to boost latching power on double lever arms. a Available in a wide range of standard or optional custom powder coat finishes to blend with door and frame. ■ Plated finishes available to accent door and frame. • Not designed for exterior mounting or exposed to elements. DESIGN ASSISTANCE LCN has been providing reliable solutions to unique door control problems for over 85 years. Design and specification assistance are only a phone call away. Contact LCN for assistance or technical information at 877-671-7011 or FAX 800-248-1460 (Order Entry), Fax 815-879-1495 for Product Support. WARRANTY 30 year limited warranty. See General Information Section for complete warranty details. SPECIFICATIONS Refer to "SPECIFICATIONS" section for suggested architectural specifications. MATERIALS • High strength cast iron cylinder. ■ Forged steel main arms. • One piece forged steel piston. • Double heat treated pinion. a All weather fluid eliminates seasonal adjustments temperatures ranging from 120° F (490 C) to -30°F. (-350 C). • High efficiency, full complement, low friction bearings. • Tamper resistant regulating screws. • Full rack and pinion hydraulic action. • Quiet, low friction track and roller combination for all single lever arm closers. FINISHES • Available in seven standard or optional custom powder coat finishes to blend with door and frame. LCN® • LCN's powder coat finishes surpass 100 hours of salt spray which is over four times the ANSI standard for corrosion resistance. • For installations where a higher level of corrosive resistance is required, LCN offers an optional special rust inhibiting (SRI) pre- treatment. Closers that combine the exclusive LCN powder coat finish and the SRI pre-treatment exceed the ANSI standard for corrosion resistance even further. • Plated finishes are available as an option to accent door and frame. (SRI not available with plated finishes). LISTINGS & APPROVALS UL listed for self-closing doors without hold -open under "SWINGING DOOR CLOSERS"(GVEV) file R1943. Tested and certified under ANSI Standard 4156.4 Grade One. Consult factory for details. Consult factory for other listings such as; cUL, California State Fire Marshal, Bureau of Standards and Appeals. POSITIVE PRESSURE LCN closers have been certified or three hours by UL to be in compliance with UBC 7,2 (1997) and UL 10C. Contact LCN for specific details on door closer fire ratings. FASTENERS 4010, 4010T, 4020, 4020T, 4040XP, 4040XPT, 4110, 4110T Series closers are shipped with: A standard SELF -REAMING and TAPPING SCREW (SRT) pack that contains Philips head SRT screws to install the closer. 4000T series closers are shipped with: A standard WOOD and MACHINE SCREW (WMS) pack that contains Philips head wood and machine screws to install the closer. 4030, 4030T series closers are shipped with: A standard WOOD and SELF -TAPPING MACHINE SCREW (WMS) pack that contains Phillips head wood and self -tapping machine screws to install the closer. Standard LCN thru bolts (TB) can be installed on 1-3/4" (44 mm) thick doors with 1/4-20 machine screws. Optional thru bolt (TB) sizes are available for 1-5/8" (41 mm) or 1-3/8" (35 mm) door thickness, but this must be specified when ordering. 11 Drill 25/64" for steel doors or Drill 3/8" for wood doors Notes: 1. For Thru Bolts, specify door thickness if other than 1-3/4"(44mm), represented in diagram as dimension "X". 2. Phillips head, metric machine screws are available, please specify. 3. LCN recommends the use of wood screws, available in optional WMS screw packs, for wood door applications. MAINTENANCE Closers mounted according to LCN installation instructions require no periodic maintenance or adjustments. 2 PHONE 877-671-7011 FAX 800-248-1460 www.allegion.com/us 4/15 009426 *PARALLEL ARM (PUSH SIDE) MOUNT *4110 HCUSH mount shown ■ Standard 4110 Series closer is shipped with Extra Duty arm, standard plastic cover, 4110-201 FIFTH SCREW SPACER and self reaming and tapping screws. See 4110 Series pages 57 & 58 for options. ■ Sized cylinders adjustable for interior doors to 5'0" and exterior doors to 4'0 ". • Non -sized cylinder adjustable for interior doors to 4' '6" and exterior doors to 3 '6". ■ Closer mounts parallel arm, specify right or left swinging door. • 4111 cylinder meets ADA requirements. See 4110 Series page 59. is Standard or optional custom powder coat finish. • Optional plated finish on metal cover, arm and fasteners. ■ Optional SRI primer for installations in corrosive conditions is available with powder coat only. • The 4110 Series is UL and cUL listed for self-closing doors without hold -open. • Tested and certified under ANSI Standard A156.4, grade one. MOUNTING FINISH COVER CYLINDER 4110 SERIES The 4110 is LCN's best performing heavy duty closer designed W t`r specifically for institutional and other rugged high traffic applications. W U. ■ Cast Iron a Extra Duty Forged Steel Arm Standard ■ Double Heat Treated Steel Pinion ■ All Weather Fluid ■ Advanced Variable Backcheck ■ LCN Patented Green Dial ■ UL & cUL Listed ■ Peel -n -Stick Templates for Fast and Accurate Installations The 4110 Series includes the LCN® "Green Dial" Spring Force Indicator **ARM FUNCTION AVAILABLE O NOT AVAILABLE LCN® Closer available with less than 5.0 lbs. opening force on 36"door. ** Maximum opening/hold-open point with standard template. *** Advanced Variable Backcheck. 55 Q 180° 180° 110° 110° O PHONE 877-671-7011 FAX 800-248-1460 www.allegion.com/us 4/15 009426 MOUNTING DETAILS 4110 SERIES SPIDER) PARALLEL UNRTINGPUSH MAXIMUM OPENING EDA or Fusible Link arm can be templated for 100° ® = 5-15/16" (151 mm) © = 7-1/4" (184 mm) 140° ® = 4-7/16" (113 mm) 0 = 5-3/4" (146 mm) or 180 ® = 2-15/16" (75 mm) = 4-1/4" (108 mm) Hold -open points up to maximum opening with HEDA or Fusible Link arm. CUSH arm can be templated for maximum opening at 85° ®= 8-5/16" (211 mm) = 9-5/8" (244 mm) 90° ® = 7-11/16" (195 mm) 0=9"(229mm) 1009 ® =6-7/16"(164mm) 0 = 7-3/4" (197 mm) or 1100. = 5-9/16" (141 mm) 0 = 6-7/8" (175 mm) Hold -open point at maximum opening with HCUSH arm. Spring Cush hold -open points are approximately 5° less than templated stop point. Options • Size 6 or non -sized cylinder. • Delayed Action and/or Advanced Variable Backcheck cylinder. • HEDA, CUSH, HCUSH, SPRING CUSH, SPRING HCUSH or Fusible Link arm. ■ Metal cover. Special Templates Customized installation templates or products may be available to solve unusual applications. ; Contact LCN Product Support for assistance. —4 102 mm —Z 4 57 mm 0 *5-11/16" (144 mm) For Fusible Link Arm Applications • Butt Hinges should not exceed 5" (127 mm) in width. a Auxiliary Stop is recommended at hold -open point, where a door cannot swing 180°, or where CUSH-N-STOP arm is not used. a Clearance for EDA, or CUSH shoe is 5-1/2" (140 mm) from door face. • Top Rail less than 5-1/8" (130 mm) measured from stop requires PLATE, 4110- 18. Plate requires 2" (51 mm) minimum measured from the stop. • Stop Width minimum 1" (25 mm). • Head Frame flush or rabetted requires CUSH FLUSH PANEL ADAPTER, 4110-419. • Reveal less than 2-3/4" (70 mm), use CUSH SHOE SUPPORT, 4110-30 with CUSH arms. • Blade Stop Spacer, 4110-61 required to dear 1/2" (13 mm) blade stop. • Cush Arm requires CUSH SHOE SUPPORT, 4110-30 for fifth screw anchorage with CUSH arms. • Delayed Action Add suffix "DEL" to selected cylinder (eg. 4111 DEL). Not available with 4116 cylinder. Delays closing from maximum opening to approximately 70°. Delay time adjustable up to approximately 1 minute. • Advanced Variable Backcheck cylinder starts backcheck at approximately 450 instead of the normal 750. Add suffix "AVB" to selected cylinder. LCN® 56 PHONE 877-671-7011 FAX 800-248-1460 www.allegion.com/us 4/15 009426 CYLINDERS CYLINDER, 4110-3071 Standard, handed cast iron cylinder assembly. For various applications see "Table of Sizes" on 4110 Series page 59. COVERS COVER, 4110-72 Standard, non -handed plastic cover. METAL COVER, 4110-72MC Optional, handed cover. Required for plated finishes and custom powder coat finishes. ARMS EXTRA DUTY ARM, 4110-3077EDA, 4110-3077EDAG Non -handed parallel arm features forged, solid steel main and forearm for potentially abusive installations. Optional 4110-626 thick hub shoe for blade stop clearance. HOLD -OPEN ARM 4110-3049EDA Optional handed arm provides hold -open function, adjustable at shoe. FUSIBLE LINK ARM, 4110-3049FL Optional, handed arm releases hold -open function adjustable at shoe when exposed to temperatures above 165° F. NOTE: Check local codes before specifingFL arms. NOTA life safety product! COSH -N -STOP ARM, 4110-3077CNS Non -handed parallel arm features solid forged steel main arm and forearm with built-in stop in soffit shoe. LCN® 57 4110 SERIES 72MC Left Hand Shown PHONE 877-671-7011 FAX 800-248-1460 www.allegion.com/us 4/15 009426 ACCESSORIES ACCESSORIES 4110 SERIES H-CUSH ARM 4110-3049CNS Non -handed arm provides hold -open function with templated stop/ hold -open points. Handle controls hold -open function. SPRING CUSH ARM, 4110-3077SCNS Optional, non -handed parallel arm for abusive applications features solid forged steel main arm and forearm with spring loaded stop in the soffit shoe. SPRING H-CUSH ARM, 4110-3049SCNS Optional, non -handed parallel arm for abusive applications features solid forged steel main arm and forearm with spring loaded stop in the soffit shoe. Handle controls hold -open function. INSTALLATION ACCESSORIES PLATE, 4110-18 Required for push side mount where top rail is less than 5-1/8" (130 mm), measured from the stop. Plate requires minimum 2" (51 mm) minimum top rail. Plate also used with CUSH Arm installations. CUSH SHOE SUPPORT, 4110-30 Provides anchorage for fifth screw used with CUSH arm, where reveal is less than 3-1/16" (78 mm). BLADE STOP SPACER, 4110-61 Lowers parallel arm shoe to clear 1/2" (13 mm) blade stop PA FLUSH PANEL ADAPTER, 4110-419 Provides horizontal mounting surface for CUSH shoe on single rabetted or flush frame. LCN® 58 PHONE 877-671-7011 FAX 800-248-1460 www.allegion.com/us 4/15 009426 TABLE OF SIZES Select closer based on width of door. The spring power of non -sized 4111 cylinder is adjustable from size 1 through size 5 and is shipped set to size 3. Sized 4116 series cylinders 6. Delayed action not available with 4116 cylinder H - CUSH and SPRING H-CUSH arm not available with 4116 cylinder. EXTERIOR (and VESTIBULE) DOOR WIDTH 28" 30" 36" 42" 48" 711mm 762mm 914mm 1067mm 1219mm 4116 size 3 Minimum Door Width size 4 *Adjustable Size 1 thru 5 INTERIOR DOOR WIDTH 28" 711mm *4111 4116 size 2 size 5 34" 38" 864mm 965mm Minimum Door Width size 6 48" 54" 60" 1219mm 1372mm 1524mm size 3 size 4 size 5 size 6 Indicates recommended range of door width for closer size. * Adjustable Size I thru 5. REDUCED OPENING FORCE 4110 CLOSERS CAUTION ! Any manual door closer, including those certified by BHMA to conform to ANSI Standard A156.4, that is selected, installed and adjusted based on ADA or other reduced opening force requirements may not provide sufficient power to reliably close and latch a door. Refer to AUTOMATIC OPERATORS section for information on systems that meet reduced opening force requirements without effecting closing power. * Maximum opening force. LCN® 59 4110 SERIES HOW -TO -ORDER 4110 SERIES CLOSERS 1. SELECT CYLINDER SIZE ❑ 4111 (adjustable from size 1 to 5) ❑ 4116 (DEL, SHCUSH or HCUSH arm not available) 2. SPECIFY HAND o RH ❑ LH 3. SELECT FINISH ❑ Standard Powder Coat Aluminum, Dark Bronze, Statuary, Light Bronze, Black, Brass. Closer will be shipped with: - STANDARD COVER, - FIFTH SCREW SPACER, - EDA ARM, - SELF -REAMING and TAPPING SCREWS unless options listed below are selected. 4110 CLOSER OPTIONS CYLINDER o Delayed Action (DEL) (not available with 4116) o Advanced Variable Backcheck (AVB) COVER o Metal (MC) FINISH o Custom Powder Coat (RAL) (handed metal cover required) ❑ Plated Finish, US (handed metal cover required) o SRI primer (use with powder coat finishes only) SPECIFY ARM o Hold -Open Extra Duty (HEDA) ❑ Fusible Link,165° F (FL) o Cush -N -Stop (CUSH) ❑ H -Cush -N -Stop (n/a with 4116 cylinder) (HCUSH) ❑Spring Cush (SCUSH) o Spring H -Cush (n/a with 4116 cylinder) (SHCUSH) ❑ Extra Duty (EDA) ❑ H -Extra Duty (HEDA) SCREW PACK o TBS, Self -Reaming & Tapping (TBSRT) o Wood & Machine Screw (WMS) oTB*, Wood & Machine Screw (TBWMS) ❑TORX Machine Screw (TORX) o TB* & TORX Machine Screw (TBTRX * Specify door thickness if other than 1-3/4': INSTALLATION ACCESSORIES ❑ Plate, 4110-18 o CUSH Shoe Support, 4110-30 o Blade Stop Spacer, 4110-61 ❑ PA Flush Panel Adapter, 4110-419 SPECIAL TEMPLATE ❑ ST - PHONE 877-671-7011 FAX 800-248-1460 www.allegion.com/us 4/15 009426 ORDERING INFORMATION & DOOR WIDTH 36" 42" 48" 8.5* lbs. 4111 4111 4111 5.0* lbs. 4111 4111 4111 * Maximum opening force. LCN® 59 4110 SERIES HOW -TO -ORDER 4110 SERIES CLOSERS 1. SELECT CYLINDER SIZE ❑ 4111 (adjustable from size 1 to 5) ❑ 4116 (DEL, SHCUSH or HCUSH arm not available) 2. SPECIFY HAND o RH ❑ LH 3. SELECT FINISH ❑ Standard Powder Coat Aluminum, Dark Bronze, Statuary, Light Bronze, Black, Brass. Closer will be shipped with: - STANDARD COVER, - FIFTH SCREW SPACER, - EDA ARM, - SELF -REAMING and TAPPING SCREWS unless options listed below are selected. 4110 CLOSER OPTIONS CYLINDER o Delayed Action (DEL) (not available with 4116) o Advanced Variable Backcheck (AVB) COVER o Metal (MC) FINISH o Custom Powder Coat (RAL) (handed metal cover required) ❑ Plated Finish, US (handed metal cover required) o SRI primer (use with powder coat finishes only) SPECIFY ARM o Hold -Open Extra Duty (HEDA) ❑ Fusible Link,165° F (FL) o Cush -N -Stop (CUSH) ❑ H -Cush -N -Stop (n/a with 4116 cylinder) (HCUSH) ❑Spring Cush (SCUSH) o Spring H -Cush (n/a with 4116 cylinder) (SHCUSH) ❑ Extra Duty (EDA) ❑ H -Extra Duty (HEDA) SCREW PACK o TBS, Self -Reaming & Tapping (TBSRT) o Wood & Machine Screw (WMS) oTB*, Wood & Machine Screw (TBWMS) ❑TORX Machine Screw (TORX) o TB* & TORX Machine Screw (TBTRX * Specify door thickness if other than 1-3/4': INSTALLATION ACCESSORIES ❑ Plate, 4110-18 o CUSH Shoe Support, 4110-30 o Blade Stop Spacer, 4110-61 ❑ PA Flush Panel Adapter, 4110-419 SPECIAL TEMPLATE ❑ ST - PHONE 877-671-7011 FAX 800-248-1460 www.allegion.com/us 4/15 009426 ORDERING INFORMATION 800-3464;0i' i :, .;:.nir!a lne',h!l t:e:.3 mcI(iiimey" Five Knuckle Heavy Weight Full Mortise Series Recommended for use on high frequency andior heavy wood or metal doors in schools, hospitals or other public buildings where heavy traffic is experienced. • Heavy weight hinges should be used on all extra heavy doors or those exposed to high frequency use • T4A3386- Stainless steel base or available in brass base material polished • T4A3786- Steel base material • For Beveled Edge, where doors are beveled on hinge side, specify T4A4386 or T4A4786 • For available finishes see page 29 Note: 8" x 6" and 8" x 8" have six bearings. SpecifyT6B3386 or T6B3786. No. ANSI Cross Reference Base Material Weight T4A3386 A5111 Stainless HVY T4A3386 A2111 Brass HVY T4A3786 A8111 Steel HVY Specifications T4A3386 T4A3786 Application ==_" No. of Fasteners Options: Inches mm Gauge Holes Machine Wood Code Description 4'12" x 4" 114.3 x 101.6 .180 8 1/2x 12-24 11/4x 12 NRP Non -Removable Pin 4'12" x 4'12' 114.3 x 114.3 .180 8 '12 x 12-24 1'14 x 12 T4B Ball Bearing 5" x 4112" 127 x 114.3 .190 8 112x 12-24 1114 x 12 TCA Concealed Bearing 5" x 5"* 127 x 127 .190 8 1/2x 12-24 1'14 x 12 RC Round Corner -'14" radius furnished unless 6" x 5"* 152.4 x 127 .203 8 112 x114-24 1'14 x 14 specified otherwise 6" x 6"* 152.4 x 152.4 .203 10 '12 x114-20 1'12 x 14 f HT Hospital Tip 8"x6"** 203.2x125.4 .203 16 112 x114-20 1112x14 BT gall Tip 8" x 8"*** 203.2 x 203.2 .203 16 112 x 114-20 11/2x 14 _ ST Steeple Tip *Not available in brass base material. SSF Safety Stud Feature **Available in steel only. RB Raised Barrel* ***Available in stainless steel only. QC Electrolynx® Hinge - 2, 4, 6, 8, 10 or 12 wire available CC Concealed Circuit - 2, 4, 6, 8, 10 or 12 wire available * Refer to page SP -3 for Raised Barrel. Cupyi fight © 2012. 2015. MJKinnev Products Company, an ASS1 ABLOY Group company All rights reserved Reproduction in whole (win pari -without the express written permission orMcKinney Pi oducts Company is prohibited CC -18 Concealed Circuit -2, 4, 6, 8 or 10 wire available (2-18AWG wires and the remainder 28AWG wires) MM Magnetic Monitoring The global leader in door opening solutions FM -13 u 011117,x.1 U 1 U�ria PEMKO800-824-3018 1 www.pemko.com Check the web site for the up-to-date catalog • SiliconSeal Adhesive -Backed Fire/Smoke Gasketing • SiliconSeal is extruded from high-temperature silicone; effective between -58°F and 450°F • Self -extinguishing and non-toxic; unaffected by sunlight, ozone, and ultraviolet rays • Impervious to fungus and mildew; will not deteriorate under normal exposure • Meets FAR 25.853 Airworthiness Standards for Compartment Interiors S44 AVAILABLE FINISHES: BL, C, D, GR, W AVAILABLE LENGTHS: 17', 18' 20', 21', 25', 30', 204', 510' ANSI: R0E154, R0E155 • Designed for tighter frames • Demonstrates extremely low closing force • Seal begins compressing at5h6"; compresses to seal up to a'/16" gap '/16tt ('7.g) Y - AdhesWa 6 Backing (11 1) / Low Cbsin0 e Fore Fin Seel / Stabilizer $ Flange r� 1 588 REass AVAILABLE FINISHES: BL, C, D, GR, TAN, W AVAILABLE LENGTHS: 17', 18', 20', 21', 25', 30', 204', 510' ANSI: ROE154, ROE155 • Seal begins compressing at'la"; compresses to seal up to a'I16' gap OA) ('a) ss...,„ Adhesive Backing (12.7) i Compression Bulb f Stabilizerange Fl ASSA ABLOY The global leader in 206 door opening solutions Hinge Jamb g.... top Header Strike Jamb 1 Opt slop -1 7 (7Mer alscurttkWy(/or I .xHLlb0a/eo>"i 6e •6(r h optreetpnpa y}. Application is acceptable anywhere along jamb face "544 shown, but application detail applies to PK33, PK55, 5442, 577, 588, 5773, and 5776 also. S442_ AVAILABLE FINISHES: BL, D, GR, W AVAILABLE LENGTHS: 17', 18', 20', 21', 25', 30', 510' ANSI: R0E154, R0E155 • Fits flush into corner • Seal begins compressing at6h6; compresses to seal up to a 'he gap in either direction %2 (12.7) rioa 5161 (7.0) 10 (12.7) I' tx 5773_ AVAILABLE FINISHES: BL, D, GR, W AVAILABLE LENGTHS: 17118% 20', 21', 25', 30', 250', 500' ANSI: R0E154, R0E155 • Triple -fin design effectively blocks light and sound from infiltrating a room • Seal begins compressingat3ta"; compresses to seal up to a '16" gap rse ®P RIM S77_ AVAILABLE FINISHES: BL, C, D, W AVAILABLE LENGTHS: 17', 18', 20', 21', 25', 30', 204', 500' ANSI: R0E154, R0E155 • Designed for hollow metal and wood meeting stile applications • Seal begins compressing at sh6"; compresses to seal up to a 'h6" gap Fin Seal %6' f Stabilizer (7:A) r Flange i Adhesive 1//+' _61 Backing (12.7) tw IJERNA 5776_ AVAILABLE FINISHES: BL AVAILABLE LENGTHS: 17',18', 20', 21', 25', 30' ANSI: R0E154, ROE155 • Designed for hollow metal and wood meeting stile applications • Seal begins compressing at 'la compresses to seal up to al/16" gap /8 a (9.5) AVAILABLE FINISHES FOR PRODUCFS SHOWN ON 1 HIS PAGE (see General Information section for finish chart) BL(Black) C(Cleat) D(Dark Brown) GR (light Gray) TAN(Tan) W(White) Copyright © 2015, Pemko Manufacturing Co„ an ASSA ABLOY Group company,All rights reserved. Reproduction in whole or in part without the express written permission of Pemko Manufacturing Co, is prohibited, PEMKO800-824-3018 I www.pemko.com Check the web site for the up-to-date catalog Saddle Thresholds • To use a saddle threshold in an offset condition, use an elevator (see page 135) 173 AVAILABLE FINISHES: A, B, D, G ANSI (aluminum): J32300, J32330 ANSI (brass): J12300, J12330 J-44 E 21/4" '1 (4.6) (57,2) 151 AVAILABLE FINISHES: A, B, D, G ANSI (aluminum): J32300, J32330 ANSI (brass): J12300, J12330 n ESSA }i E 1/4"J i 3" (6.4) (78 2) 270 AVAILABLE FINISHES:A, B, D, G ANSI (aluminum):J32100, J32130 ANSI (brass): J12300, J12330 —j 4" 4 (6.4) (101 6) 271 EfiCm AVAILABLE FINISHES: A, B, D, G, SN ANSI (aluminum): J32100, J32130 ANSI (brass): J12100, J12130 .r 1/4.. . 5" (6.4) (127.0) 272 AVAILABLE FINISHES: A, B, D, G, SN ANSI (aluminum): J32100, J32130 ANSI (brass): J12100,112130 maw 6„ (6.4) (152.4) ASSA ABLOY The global leader in 104 door opening solutions NOTE: Products shown in this section may not be drawn to scale. AVAILABLE FINISHES FOR PRODUCTS SHOWN ON THIS PAGE (see General Information section for finish chart) A (Mill Finish Aluminum) B(MIIIFinish Extruded Bronze iBrassl) (2 (Oark Bronze Anodized) G (Gold Anodized) SN (Satin Nickel Anodized) NOTE: G, SN are available with limited inventory Copyright © 2015, Pe mko Manufacturing Co„ an ASSA ABLOY Group company, All rights reserved, Reproduction in whole or in part without the express written permission of Pernko Manufacturing Co. is prohibited, 0= Mop Plate Up to 6"h x48"w <ick Plate 6" to 12' h x48"w Stretcher Plate 6"to12"h and upto48"w Width of Plates: Push Side: 2" less than door width. Pull Side:11/2" less than door width. NFPA 80 STANDARDS — 2-4.5 Protection Plates: Factory -installed protection plates shall be installed in accordance with the listing of the door. Field -installed protection plates shall be labeled and installed in accordance with their listing. Exception: Labeling is not required where the top of the protection plate is not more than 16" (406 mm) above the bottom of the door. R000/001)�. Armor Plate Upto48"hx48"wand available in most finishes OPTIONAL Self-DrillingTEK Screws Cuts door plate installation time in half. Metal Door Plate - Economy Duty No.1<1038 Material: Finishes: Fastener: Ordering: Weight: Options: .038" aluminum, stainless steel Brass look aluminum (BRS LK), US32D, and US3LIFETIME #6x518" OH SMS Specify height x width x finish code. Add any options 8"x 34" = 3.2 lbs • SA -self-adhesive mounting • TORX-securityTorxscrews • TEK-self-drilling screws • Cutouts for locks, louvers, or windows (see worksheets on pages C14 -C15 for details on how to order) Metal Door Plate - Standard Duty N Material: Finishes: Fastener: Ordering: Weight: ANSI: .050" aluminum, brass, bronze, stainless steel Available in standard architectural finishes, US32DMS, US32D316, and US32316 (see page 9) #6x518" OH SMS Specify height x width x finish code. Add any options 8"x34"=4.0lbs J101 - metal armor plate, J102 - metal kick plate, J103 - metal stretcher & mop plate 1<1050F Options: • SA -self-adhesive mounting • TEK - self -drilling screws Beveled 3 or 4 edges, specify B3E or B4E • Cutouts for locks, louvers, or windows (see worksheets on pages C14 -C15 for details on how to order) • Heavy bevel available, specify HVBEV • Screw mounting (K1050F) and UL listed for use on 90 -minute label wood doors and 3 -hour label metal doors O • CSK-countersunk holes • TORX - security Torx screws Copyi ighr (0 2012.2015 Rockwood Manufacturing Company, an ASSA ABLOY Group crnnpany, All rignrs reserved Reproduction in whole or in parr without the express written permission of Rockwood .bianufaci w ing Company is piohibired_ ASSA AB I The global leader in door opening solutions C1 ,.O` PLA Popular double door applications Single door applications Single mortise lock device Door handing Left hand -reverse orientation Single rim device Right hand -reverse orientation LHR (Left hand -reverse) RHR (Right hand -reverse) Outside Outside trim operation Trim operation lever or knob Double door applications Mortise lock and surface mounted concealed vertica cable/rod device combination—same direction ArrAmg Two rim devices with mullion— same direction Two surface mounted vertical rod Two fire exit hardware vertical devices—same direction (do not use cables/rods with auxilary fire with overlapping astragal) latch-LBR option ;-U i 4 A 4 i )11111=9 0 Two vertical rods—double egress Two concealed vertical cables/rods Standard } Key locks and unlocks lever or knob. e.g„ 996L (Classroom) Night latch Key retracts latch bolt, Lever or knob is rigid. Use NL suffix, e,g. 996LNL. (Storeroom) 996L Breakaway" lever The 996L Breakaway trim has become the standard lever trim offering on the 98L/99L Series devices. The Breakaway design is especially effective in areas where vandalism to door hardware is a problem. The design intent is to discourage costly repairs from becoming necessary. The Breakaway feature is not available on the NL (night -latch) or DT (dummy trim) versions. r • Von Duprin 98/99 Series Blank escutcheon } Lever or knob always active. Use BE suffix, e.g., 996L -BE, (Passage) Dummy Lever or knob rigid for pull operation. Use DT suffix, e.g., 996L -DT. 374T/376T Series thumbturn control Standard operation, key locks and unlocks thumbturn. Optional operation, key unlocks thumbturn, re -locks when key is removed. This operation Is created by changing the cylinder plate included with control. Use 1'/<" mortise cylinder with a straight cam. Schlage cam reference B502-191. Use with a pull trim (990DT pictured). L4) i it A Two concealed vertical cables/rods Standard } Key locks and unlocks lever or knob. e.g„ 996L (Classroom) Night latch Key retracts latch bolt, Lever or knob is rigid. Use NL suffix, e,g. 996LNL. (Storeroom) 996L Breakaway" lever The 996L Breakaway trim has become the standard lever trim offering on the 98L/99L Series devices. The Breakaway design is especially effective in areas where vandalism to door hardware is a problem. The design intent is to discourage costly repairs from becoming necessary. The Breakaway feature is not available on the NL (night -latch) or DT (dummy trim) versions. r • Von Duprin 98/99 Series Blank escutcheon } Lever or knob always active. Use BE suffix, e.g., 996L -BE, (Passage) Dummy Lever or knob rigid for pull operation. Use DT suffix, e.g., 996L -DT. 374T/376T Series thumbturn control Standard operation, key locks and unlocks thumbturn. Optional operation, key unlocks thumbturn, re -locks when key is removed. This operation Is created by changing the cylinder plate included with control. Use 1'/<" mortise cylinder with a straight cam. Schlage cam reference B502-191. Use with a pull trim (990DT pictured). L4) op - 1 • 1 98/99 Rim exit device l 98 and 99 Rim exit devices for all types of single and double doors with mullion, UL listed for panic exit hardware. Devices are ANSI A156.3 — 2008 Grade 1. The 98 device has a smooth mechanism case and the 99 device has a grooved case. The rim device is non -handed except when the following device options are used: SD (special dogging), -2 (double cylinder) or SS (signal switch). See Opposite page for available outside trim and device functions. Covers stock hollow metal doors with 86 or 161 cutouts on single doors (may cover cutouts on pairs — consult template). Finishes — US3, US3A, US4, US4A, US10, US26, US260, US26D-AM Antimicrobial, US28, 313, 315 & 643E. US15 and U532D available with 98 Series only. Specifications Device functions Device ships EO/DT/NL. Field selectable. For TP, K or L remove NL drive screw from device. Device lengths 3' 2'4' to 3' (711mm to 914 mm) Door size 4' 2'10" to 4' (864 mm to 1219 mm) Door size Device centerline from finished floor 39 n/,o' (1011 mm) 39"/6" (1008 mm) with mullion Center case dimensions 8"x23/4"x23/6"(203mmx70mmx60mm) Mechanism case dimensions 2'/4" x 2'/4" (57mm x 57mm) Projection Pushbar neutral — 3/.6"(97mm) Pushbar depressed — 3'/." (78 mm) Latch bolt Deadlocking, 3/;' (19mm) throw Fasteners & sex bolts (SNB) Includes screw pack for 13/." (44mm) and 21/2" (57mm) thick metal or wood doors. Optional 425 SNB available, see page 9 for quantities. i i7I3 • • • LX Latchbolt monitor switch RX Pushpad monitor switch RX2 Double pushpad monitor switch E Electric locking & unlockingtr EL Electric latch retraction QEL Quiet electric latch retraction SS Signal switch CX Chexit delayed exit ALK Alarm exit kit WP -RX Waterproof request to exit CON Alleglon Connect Mail-a-ftwi options -2 Double cylinder AX Accessible device GBK Glass bead kit PN Pneumatic latch retraction XP Extra protection SNB Sex bolts SEC Security screws og: ing. e- ' re Dogging opt ons - Hex key dogging standard CD Cylinder dogging SD Special center case dogging LD Less dogging DI Dogging Indicator CI Cylinder dogging Indicator 299 — Dull black 1 • Von Duprin 98/99 Series 4 The 299 Strike ships standard, optional strikes available Hex key dogging comes standard on 98/99 Rim exit devices Extra protection • 90° latch -to - strike contact • Force resistance of 2,000+ lbs. 1 Quiet electric latch retraction • Bolt retraction via switch • Converts exit door to push-pull operation /SDI Cylinder dogging • Replaces hex key dogging • Requires 1'/h' mortise cylinder with Inverted cam Chexit delayed exit • Meets NFPA 101 requirements • Self-contalned controls, locking. alarm rElectric latch retraction • Enables remote unlatching • Alternative to manual dogging Pneumatic latch retraction • For areas where electrical devices banned • Special linkage for mechanical or pneumatic dogging Pushpad monitor switch • Signals use of an opening • SPDT switch to monitor pushpad Accessible device • UL certified to meet new 51b. maximum operating force requirement • Exceeds ANSI/ BHMA requirements Alarm exit kit • Unauthorized opening triggers 85 -decibel horn • Set In armed or disarmed mode by key Alleglon Connectors • Common connectors to connect various door hardware all the way to the power supply Standard trim Electrified lever operation available Notes • Von Duprin 98/99 Series • 9 EO No outside trim Exit only DT i Dummy trim Pull when dogged NL _ Night latch Key retracts latchbolt NL -OP Q Night latch Key retracts latchbolt optional pull required Product description 98E0 99E0 98DT 990T 98NL 99NL 98NL-OP 99NL-OP Trim description990DT — 996L -RN* 990NL-R/V 110NL-MD 110NL-WD Escutcheon plate_ size Escutcheon plate size 3" x 14"/K' x'hz' (76x360x2mm) 3" x 14'3/W x'/3:" (76x360x2mm) — Pull center to center — 5'h" (140mm) 5'h" (140mm) — Projection — 2" (51mm) 2" (51mm) — ANSI function 01 02 03 03 Cylinder type — — Rim Rim Handing — — — — Optional trim x990E0 x996E0 x996K-DT x996L-DT x696DT x697DT x996K-NL x996L-NL x696NL x697NL 2 Optional #425 SNB quantity for device 6 2 2 6 Electrified lever operation available Notes • Von Duprin 98/99 Series • 9 L P Lever Key locks & unlocks L -NL i s 1 ___.) Lever - night latch Key retracts latchbott L -BE ,- 6001L i 1 ._.r Lever - blankescutcheon Always operable (no cylinder) -DT 1 ____, Lever dummy trim pull when dogged Product description 98L 99L 98L -NL 99L -NL 98L -BE 99L -BE 98L -DT 99L -DT Trim description 996L -RN* 996L-NL-R/V 996L -BE -RN* 996L -DT Escutcheon plate size 2=/<" x 10"h" x "'h:" (70x273x21mm) 2'/4' x 10'/." x 2/32" (70x273x21mm) 2"h" x103/.." x "/3:" (70x273x21mm) 2'/." x 10'/." x "h:" (70x273x21mm) Pull center to center — — — — Projection 27." (73mm) 2'/a" (73mm) 2'/"" (73mm) 2'/8" (73mm) ANSI function 08 03 14 02 Cylinder type Rim Rim —. — Handing Handed/Reversible Handed/Reversible Handed/Reversible Handed/Reversible Optional #425 SNB quantity for device 2 2 2 2 Electrified lever operation available Notes • Von Duprin 98/99 Series • 9 98/99 Strike/Stile information Devito typo Standard single doer Standard doubt* door Dpttonai stristadoor ` Optional doubi•door 98/99 Strike Trim/Stile Strike w/ mullion* Trim/Stile Strike Trim/stile Strike w/mullion* Trim/Stile 299 990/996 696/697 990/996 696/697 990/996 696/697 990/996 696/697 4'/," (114mm) 43/a^ (111mm) 299 x 4954 /+�/"" (124mm) 43/4" (121mm) 1439 or 1410 3,3/." (97mm) 3'1." (97mm) 299 x 5654 4'/n° (113mm) 4'/d' (108mm) 1408x5754 3"/.' (97mm) 3"/." (97mm) 1606 4 /'6 " (103mm) 3',/." (100mm) 1606 x 1654 4'/." (112mm) 4'/," (108mm) XP 98/99 909 909 x 4954 -XP - - - 98 -F/99 -F 299F 4'/:" (114mm) 4'/." (111mm) 499E x 9954 4'/." (124mm) 4'/P (121mm) _ _ 499E x 9854 KR9954 XP98-F/XP99-F 909 954x 9954 -XP - 9875 9975 575 4'/," (121mm) 4'/." (121mm) 575-2 - - - - - 576A-5768 4'/." (121mm) 4'/." (121mm) 9875-F 9975-F 575 414 (121mm) 41, (121mm) 575-2 - - 576A -576B 4'/." (121mm) 4'/," (121mm) 9857 9957 299 (Top) 299 (Middle) 304L/284 -L (Bottom) 4'/," (114mm) 4'/." (111mm) 299 x 4954 41." (124mm) 43/4" (121mm) 1439 or 1410 3"/M" (97mm) 3"/$' (97mm) 299 x 5654 4'/." (113mm) 4'/." (108mm) 1408x5754 3"/e' (97mm) 3°/b' (97mm) 1606 4'/.. (103mm) 3 5/16 (100mm) 1606 x 1654 4'/." (112mm) 4'/." (108mm) 9857-F 9957-F 299 (Top) 299E (Middle) 304E (Bottom) 4'/," (114mm) 4'/." (111mm) 299E 499F x 9954 304L 4'/." (124mm) 43/." (121mm) - - - - Strike Application Trim/Stile Optional strike Application Trim/Stile 9827 9927 Latch retraction 299 (Top) 304L/248 -L-4 (Bottom) Single door Two vertical rod devices Vertical rod with Mortise lock device 990/996 696/697 260U (TOP) 385A (Bottom) Single door Two vertical rod devices Vertical rod with Mortise lock device 990/996 696/697 3"/." (94mm) 3"/." (94mm) 43/4" (121mm) 3'/." (92mm) 35/." (92mm) 411' (121mm) 3"/•." (94mm) 3"/." (94mm) 43A " (121mm) 3s/." (92mm) 35/d' (92mm) '/ 4." (121mm) PL9827/PL9927 Pullman latch 299(Top) 304L/248 -L-4 (Bottom) 9827-F 9927-F 299 (Top) 304L (Bottom) 260U (Stainless) 385A (Bottom) 9847 9947 9848 9948 338 (Top) 385A (Bottom) 304L (Bottom) 9847-F 9947-F 9848-F 9948-F 338 (Top) 385A (Bottom) Two vertical rods Vertical rod with Mortise lock device 4'/," (108mm) 4'/1' ` (121mm) 4'/." (105mm) 4'/d' (121mm) 304L (Bottom) Two vertical rods Vertical cl rod Mortise lock device 41," (108mm) 4'/` ; ' _ _ (121mm) 4'/d" (105mm) 4'/` , _ _ -,. (121mm) 9847WDC 9947WOC 338 (Top) 3854 (Bottom) Single door Two vertical rod devices Vertical rod with Mortise lock device 4'A (108mm) 41." (108mm} 4'/." (121mm) 4'1, (108mm) 4'/." (108mm) 4'/:" (121mm) 304L Single door Two vertical rod devices Vertical rod with Mortise lock device 4y1., (108mm) 4'/d' (108mm) 4'/." (121mm) 414" (108mm) 4'/<" (108mm) 4'/." (121mm) 9847WDC-F 9947WDC-F 9849 9949 9849 9949 338 (Top) 385A(Bottom) 249 (Top) 349 (Bottom) Two vertical rod devices Vertical cable with Mortise lock device 4'/," (108mm) 4'/." (121mm) 4'/," (108mm) 4'/," (121mm) 304L Two vertical rod devices Vertical cable with Mortise lack device 41." (108mm) 4'/." (121mm) 4'/." (108mm) 4'/," (121mm) 9849-F 9949-F 9849-F 9949-F 249 (Top) 349 (Bottom) Two vertical cables Vertical cable with Mortise lock device 4'/." (108mm) 4'/," (121mm) 4'/." (108mm) 4'/." (121mm) i Two vertical cable Vertical _ _ _., cable with Mortise lock device J 4'/," (108mm) 4'/." (121mm) 4'/d" (105mm) 414" (121mm) 9949WDC 249 (Top) 349 (Bottom) Single door Two vertical cable devices Vertical cable with Mortise lock device 4,/`. (lOBmm) 49849WDC lO (lOBmm) 4'/." (108mm) 4�/'" (108mm) 4 (lOBmm) 41,' (108mm) - Single door "(WE) vertical de s 1 devices -•.-.. Vertical_. cable with Mortise lock device 4'/." (108mm) 41," (108mm) _ . 4'/," (121mm) 4'/," (108mm) 4'/4" (108mm) 4'/." (121mm) 9849WDC-F 9949WDC-F 249 (Top) 349 (Bottom) Two vertical cable devices 4'/," (108mm) 4'/4" (108mm) Two Vertical Cable Devices 4'/." (108mm) 41." (108mm) ,0 • Von Duprin 98/99 Series 98/99 Strike information Strikes for rim devices 264 rrr(7 �L 2m (32mm) 1v44- (32mm) 299F Tarmor) (73mm) _ r l4mm1 1)h• (3II4,n 1'h- N- T usrm Projection °/16" (14mm) 1410—Integral stop 499F 1408 $100 T 3'A.' (87mm) (l ) Projection"/+6" (21mm) Projection 15/16" (24mm) One per pair of doors 1606 1609 Projection '/:' (l3mm) Projection '/:" (13mm) Projection'/a" (10mm) Panic devices only xvr cp '1.11'he 14- 14a. a7mnu a7mm) Rin) — Requires coordinator — For panic exit application only, not fire rated XP Strikes for rim devices 909 mm 1 3'N.' (44m) 954 rmn) i . d x.. 14' -_ 1 ((221 mm) 14' (32 mrn) Projection'/s' (22mm) - For fire rated double door Projection 13/.R' (21mm) applications Strikes for vertical rod devices Strikes for vertical cable devices 249 - Top strike (25 mn) . mm) 349 - Bottom strike (4 >OO - -U L 244' r L (3 mm) Projection gin" (14mm) Projection'/3" (3mm) 1 tlf 24BL-4 2600 -Flush transom panic only 299 260U -F -Flush transom fire only (64mm) -► 4- $u ( 4mm) Projection'/," (10mm) P-01 T 2'h' 0 0 (64mm) 14471.11 (41 mm) Projection'/4" (10mm) torr: f 1 O (7 m ) �1... �i 3mm -114tv. (32+nm) (6mr21) Projection 13/43 (21mm) (11" (21mm) 299F (73mm) —1i rt: G (32mm) Projection 1/2/.6" (21mm) a [a 1 304L 338 I Ph (48mm) T (48mm) 4- Projection 1'/16" (21mm) Mortise'/a" (16mm) 385A 283 I® vs: Mortise 2'/:' (64mm) 2' (61mm) For use with WDC devices when used with wood frames Strikes for mortise rod devices 575 ` 1354 (27mm) - -t-- 4'h' (224mm) (32mm) For use on 13/4" (44mm) or 2114' (57mm) Single door and 21/4' (57mm) double door with coordinator. 575-2 576A 5768 .A ° ,. (23mm) For use on 1314' (44mm) 42h• thick double (124mm) door with 1±. coordinator and astragal. -►j 14. 1 v." (32mm) 1% 13/.'(44mm) 2vilci4 2'/4*(57mm) -1--f--Open back strike - Open back strike tor 13/4" (44mm) for 21/4" (57mm) 4')' thick double thick double (r24mm) doors without -I.(12481m)doors without —r—t. coordinator. coordinator. 11 )E- Ili: -101 Fs- 13/4" I(32mm) (32mm) I- — Not for use with astragals — For use on wood doors. contact door manufacturer i Acceptable for 90 minute pair of hollow metal doors Von Duprin 98/99 Series 51 1 1 1 0 0 98/99 Function, grade, type options ANSI Function, grade & type Function Grade 1, type 1 Grade 1, type 2 Grade 1, type 3 Grade 1, type 7 Grade 1, type 7 Grade 1, type 8 Grade 1, type 8 Grade 1, type 8 Grade 1, type 9 1 98E0 & F 99E0 & F 9827E0 & F 9927E0 & F 9875E0 & F 9975E0 & F 9847W DCE0 & F 9947WDCE0 & F 9849 W DCEO & F 9949WDCE0 & F 9847E0 & F 9947E0 & F 9848E0 & F 9948E0 & F 9849E0 & F 9949E0 & F 9857E0 & F 9957E0 & F 2 98DT 99DT 9827DT 9927DT 9875DT 99750T 9847WDCDT 9947WDCDT 9849WDCDT 9949WDCDT 98470T 9947DT 9848DT 9948DT 9849DT 9949DT 9857DT 9957DT 3 r 98NL&F 99NL&F 9827NL&F 9927NL&F 9875NL&F 9975NL&F 9847WDCNL&F 9947WDCNL&F 9849WDCNL&F 9949WDCNL&F 9847NL&F 9947NL&F 9848NL&F 9948NL&F 9849NL&F 9949NL&F 9857NL&F 9957NL&F 3 98K -NL & F 99K -NL & F 9827K -NL & F 9927K -NL & F 9875K -NL & F 9975K -NL & F 9847WDCK-NL & F 9947WDCK-NL & F 9849WDCK-NL & F 9949WDCK-NL & F 9847K -NL & F 9947K -NL& F 9848K -NL & F 9948K -NL & F 9849K -NL & F 9949K -NL & F 9857K -NL & F 9957K -NL& F 3 98L -NL & F 99L -NL& F 9827L -NL & F 9927L -NL& F 9875L -NL & F 9975L -NL& F 9847WDCL-NL & F 9947WDCL-NL& F 9849WDCL-NL & F 9949WDCL-NL& F 9847L -NL & F 9947L -NL& F 9848L -NL & F 9948L -NL& F 9849L -NL & F 9949L -NL& F 9B57L-NL & F 9957L -NL& F 5 98TP & F 99TP & F 9827TP & F 9927TP & F 9875TP & F 9975TP & F 9047W DCTP & F 9947WDCTP & F 9849W DCTP & F 9949WDCTP & F 9847TP & F 9947TP & F 9848TP & F 9948TP & F 9849TP & F 9949TP & F 9857TP & F 9957TP & F 7 98TP-2 & F 99TP-2 & F 9875TP-2 & F 9975TP-2 & F 8 98K & F 99K & F 9827K & F 9927K & F 9875K & F 9975K & F 9847WDCK & F 9947WDCK & F 9849WDCK & F 9949WDCK & F 9847K & F 9947K & F 9848K & F 9948K & F 9849K & F 9949K & F 9857K & F 9957K & F 8 98L&F 99L& F 9827L&F 9927L & F 9875L&F 9975L& F 9847WDCL&F 9947WDCL& F 9849WDCL&F 9949WDCL& F 9847L&F 9947L& F 9848L&F 9948L& F 9849L&F 9949L& F 9857L&F 9957L& F 10 98K-2 & F 99K-2 & F 9875K-2 & F 9975K-2 & F 10 98L-2 & F 99L-2 & F 9875L-2 & F 9975L-2 & F 11 12 9827TL & F 9927TL& F 9847WDC & F 9947WDC & F 9849WDC & F 9949WDC & F 9847TL & F 9947TL & F 9848 & F 9948& F 9849 & F 9949& F 9857TL & F 9957TL& F 14 98K -BE & F 99K -BE & F 9827K -BE & F 9927K -BE & F 9875K -BE & F 9975K -BE & F 9847WDCK-BE & F 9947WDCK-BE & F 9849WDCK-BE & F 9949WDCK-BE & F 9847K -BE & F 9947K -BE & F 9848K -BE & F 9948K -BE & F 9849K -BE & F 9949K -BE & F 9857K -BE & F 9957K -BE & F 14 98L -BE & F 99L -8E & F 9827L -BE & F 9927L -BE & F 9875L -BE & F 9975L -BE & F 9847WDCL-BE & F 9947WDCL-BE & F 9849WDCL-BE & F 9949WDCL-BE & F 9847L -BE & F 9947L -BE & F 9848L -BE &F 9948L -BE & F 9849L -BE &F 9949L -BE & F 9857L -BE & F 9957L -BE & F 16 98277L -BE & F 9927TL-BE & F 9847WDC & F 9947W0C & F 9849WDC & F 9949WDC & F 9847TL-BE & F 9947TL-BE & F 9848 & F 9948 & F 9849 & F 9949 & F 9857TL-8E & F 9957TL-BE & F Dimensions 2%" (70mm) (20 8" _ (203mm) 1 23/e" (60mm) k 33"(838mm) 45"(1143mm) 18"(457mm) 24"(610mm) 14— {I 21/4" (5 7mm) ' 1 I I 21/4" Neutral: 313/18' (97mm) (57mm) Depressed: 31/,6" (78mm) Von Duprin 98/99 Series • 67 98/99 Electrical options RX Request to exit The RX (2xit) feature is used to signal the use of an opening. This device is equipped with one internal SPDT switch which monitors the pushpad. The device can be connected to a security console, or may be used as a single door alarm when used with a horn and power supply. The RX switch option should not be used to control a load, but as a signalling switch (0.5 amps. resisitive maximum). The RX switch is available in a low current (LC) switch. Most commonly used In computer operated monitoring systems. To order, specify: • Standard — use prefix RX, example RX99EO Low Current — use prefix RX -LC, example RX-LC98EO RX2 Double request to exit The RX2 feature uses two RX switches. To order, specify: • Standard — Use prefix RX2, example RX299EO WP -RX Waterproof request to exit LX Latchbolt monitoring The LX feature is used to signal the use of an opening. This device is equipped with one Internal SPDT switch which monitors the latch bolt. The device can be connected to a security console, or may be used as a single door alarm when used with a horn and power supply. The LX switch option should not be used to control a load, but as a signalling switch (0.5 amps. resistive maximum). The LX switch Is available in a low current (LC) switch. Most commonly used in computer operated monitoring systems. To order, specify: • Standard — Use prefix LX, example LX99EO • Low Current — Use prefix LX -LC, example LX-LC98EO Electrical rating for all switches: • Standard — 2 Amp maximum @ 24VDC • Low Current (LC) - below 50 Milliamps @ 24VDC Note: All switches can be either factory or field Installed GE EXIT ONLY & SOUND ALARM SS Signal switch Monitors pushpad and latch bolt The SS feature is used to signal the unauthorized use of an opening. This device is equipped with two Internal SPDT switches. One switch monitors both the pushpad and the latch bolt assembly, making the latch bolt tamper resistant, for positive security. An additional SPDT switch is connected to the 1'16" (32mm) mortise cylinder with straight cam for alarm "bypass." (Schlage cam reference B502-191). The device can be connected to a security console, or may be used as a single door alarm when used with a horn and power supply. Pushpad reads: "Emergency Exit ONLY — Push To Open And Sound Alarm.' Pushpad is only available in US32D finish with red silk-screened lettering. The SS mortise lock device is furnished with both the signal switch device and the SS7500 mortise lock. The SS7500 mortise lock has the versatility and advantages of the 7500 lock with the addition of signalling functions to monitor latch bolt operation and the trim locking function. The SS7500 mortise lock Is supplied standard with the SS mortise lock device. To order, specify: 1. Prefix 55, example SS99L. 2. Handing required, LHR or RHR. Electrical ratings: Up to 2.0 AMPS @ 24VDC Popular SS application Unauthorized use of this opening will activate the local horn. The key switch permits inhibiting this system for authorized entry. Horn E ectric Power T anger Key Switch (exterior) Power Supply Von Duprin 98/99 Series • 53 98/99 Electrical options EL Electric latch retraction The EL feature allows for the remote unlatching of exit devices. A control station operator can flip a switch to retract the latch bolt and immediately change an exit door to push-pull operation. A powerful, continuous duty solenoid retracts the latch bolt, either for momentary unlatching, or for extended periods of time. The EL feature is an alternative to manual dogging. If manual hex -key dogging Is required, specify HD -EL. If cylinder dogging is required, the standard cylinder dogging is not available, but special center case dogging is available, specify SD -EL. SD -EL is not available on the 9875 or 9975 devices. EL devices are also useful with automatic door operators, and may be applied to fire -rated applications when under the control of an automatic fire alarm system. UL approved for Class 11 circuit applications. The EL option does not include the power transfer from door to frame, the power supply, or the control operator. Refer to EPT-2 power transfer and the PS914 power supply. The PS914 with the 9002RS option card is the minimum option card required. Other option cards available for other functions, see PS914 power supply for additional information. Solenoid specifications: Solenoid resistance: Continuous duty — 24 VDC -grn-yel 1.2 — 2.2 OHMS Current inrush —16 Amps -grn-org 100 —150 OHMS Current holding — 0.3 Amps To order, specify: Standard — use prefix EL, example EL99L. Hex Key dogging — Use prefix HD -EL, example HD-EL99L special center case dogging — Use prefix SD -EL, example SD-EL99L Popular EL application Power supply PS914-2RS Electric power transfer EPT-2 or EPT-10 12VAC40 a` b* I sc 11 01 12 E PT -2 EL #2 Input #2 p\ (Required for Independent operation only). h* EL #1 Input #1 Von Duprin exit device EL Wire length (feet)' Wire gauge (AWG) up to 2 amps 0-500 12 EL 98/99 Rim 0-300 14 12 AWG 0-200 16 1200 ft. Max. 0-250 12 All other 98/99EL device types 0-150 14 0-100 16 Control Switch 0-1200 18 1, Wire lengths include an EPT, Door loop, electric hinge or pivot and are measured one way between the PS914/option board and the device. 2. Table Is applicable to devices that have shipped after August 2012, QEL Quiet electric latch retraction The QEL feature allows for the remote unlatching of exit devices. A control station operator can flip a switch to retract the latch bolt and immediately change an exit door to push-pull operation. Different than the popular EL, the QEL quiet operation is achieved using an electric drive motor which retracts the latch bolt either momentary unlatching or for extended periods of time. This feature is an alternative to manual dogging. If cylinder dogging is required, the standard cylinder dogging is not available, but special center case dogging Is available, specify SD-QEL. SD-QEL Is not available on the 9875 or 9975 devices. QEL devices are also useful with automatic door operators, and may be applied to flre-rated applications when under the control of an automatic fire alarm system. UL approved for Class it circuit applications. The QEL option does not include the power transfer from door to frame, the power supply, or the control operator. Refer to EPT-2 power transfer and the PS902 or 914 power supply. The PS902/914 with the 2RS, 4RL or 4R board Is the minimum required. Other option boards available for other functions, see PS902/914 power supply for additional information. The QEL has a low in rush current, so it can be used with standard Schlage power supplies. Calculate the peak current draw of all devices in the system to determine the required amperage of the supply. Schlage PS902 Schlage PS904 Schlage PS906 up to 2 amps up to 4 amps up to 6 amps QEL Electrical load Voltage 24VDC Current 1.0 A Inrush (0.5 sec.) / 0.14 A Holding The -2RS option board Is designed to control two electric latch retraction devices and provide time delay between the firing of outputs is required. The power transfer is also sold separately. To order, specify: Standard — use prefix QEL, example QEL99L. Special center case dogging — use prefix SD-QEL, example SD-QEL99L a` b' 120/240 VAC *ON o, tf 01 ONO Popular application Power supply PS902-2RS Electric power transfer EPT-2 or EPT-l0 EPT-2 QEL #1 Input#2 (R/qulred for Indepnndont Ope,w00 oreV) Input #t Distance (one-way) Wire gauge 200' 18 AWG 320 " 16 AWG 500 " 14 AWG 800 " 12 AWG Wire selection Switch wire size 1200 ft. Max. 18 gauge standard Von Duprin 98/99 Series • 57 98/99 Electrical options Power Supplies Series PS902/914 Overview: The PS900 Series is a consolidated line of power supplies and accessories that offer enhanced flexibility and functionality specific to the changing needs of the access control market. The PS900 Series can be used in a variety of applications to convert high voltage AC power into the low voltage DC outputs required by most access control devices. The PS900 Series protects devices downstream by providing Class 2*, filtered and regulated power. The full line is UL294 certified. Note P5906 can provide Class 2 rated outputs when used with 900-8P distribution board. Features: Constant output rating at both 12 VDC and 24 VDC provides superior performance ; includes field selectable jumper Polarized connectors for option boards eliminate need for racks and side connectors Flat mounting of option boards provides easier access to terminal blocks for connection of electrified devices High voltage protective cover Battery back-up board auto -selects voltage Fire alarm relay can be configured to provide either switched or un -switched outputs from a power supply PS914 designed with high in rush current for powering electrified panic devices Universal 120-240 VAC input Low voltage DC, regulated and filtered Electronic power limiting foldback circuit for AC current overload protection Fused primary input AC status monitor- isolated SPDT contacts AC input and DC output LED status indicators Cover mounted AC input Indication Hinged cover with Lock down screws Certifications: • UL 294 certified—the standard for access control • Class 2 rated* + Except PS906, output rating exceeds Class 2 power limits Once power is converted to low voltage DC, the PS900 Series offers a variety of distribution options, including basic fuse protection, simple relay, and advanced logic providing complex sequencing and timing functions. ' PS906 can provide Class 2 rated outputs when used with 900-8P distribution board. i8 • Von Duprin 98/99 Series Note: One fire alarm board can be connected directly to the P5902. If a fire alarm board is desired for the P5904, PS906 or PS914 It can be connected to a distribution board. Applications: The PS900 Series of power supplies works with many electrified devices including Schlage electromagnetic locks, Schlage AD -Series hardwired locks, Schlage electrified mechanical locks, Von Duprin electrified strikes , Von Duprin exit devices, and many other brands. Accessories: The Schlage PS900 Series features seven option boards for use in a variety of applications. All Schlage P5900 Series power supplies option boards are UL 294 certified. Option boards: 900-4R: 4 relay controlled output board to power multiple devices 900-4RL: 4 relay distribution board with logic is field configurable for time delay function, auto operator, security interlock 900-8F: Provides 8 individually fuse -protected outputs, giving the flexibility to power multiple devices and provide another layer of protection 900 -FA: Emergency interface relay Integrates with fire alarm and is used to cut power in case of emergency 900 -BB: Battery backup 900-2RS: 2 relay EL panic device control board (P5914 only) 900-BBK: Battery backup kit includes two 7A/hr batteries and provides up to four hours of backup power when cycled every 5 minutes at full load PS902 PS904 PS906 P5914 Number of connectors on power supply for the following: tamps 4amps 6amps 4amps Distribution boards 1 2 3 2 Battery back-up board 1 1 1 1 Note: One fire alarm board can be connected directly to the P5902. If a fire alarm board is desired for the P5904, PS906 or PS914 It can be connected to a distribution board. Applications: The PS900 Series of power supplies works with many electrified devices including Schlage electromagnetic locks, Schlage AD -Series hardwired locks, Schlage electrified mechanical locks, Von Duprin electrified strikes , Von Duprin exit devices, and many other brands. Accessories: The Schlage PS900 Series features seven option boards for use in a variety of applications. All Schlage P5900 Series power supplies option boards are UL 294 certified. Option boards: 900-4R: 4 relay controlled output board to power multiple devices 900-4RL: 4 relay distribution board with logic is field configurable for time delay function, auto operator, security interlock 900-8F: Provides 8 individually fuse -protected outputs, giving the flexibility to power multiple devices and provide another layer of protection 900 -FA: Emergency interface relay Integrates with fire alarm and is used to cut power in case of emergency 900 -BB: Battery backup 900-2RS: 2 relay EL panic device control board (P5914 only) 900-BBK: Battery backup kit includes two 7A/hr batteries and provides up to four hours of backup power when cycled every 5 minutes at full load 1 s 4 r t 0 EPT Electrical power transfer PNT Pneumatic transfer Electric Power Transfer provides a means of transferring electrical power from a door frame to the edge of a swinging door. The units are completely concealed when the door Is In the closed position, and are ideal for Installations Involving abuse or heavy traffic. Two models are available: EPT-2, two 18 gauge wires and EPT-10, ten 24 gauge wires. The EPT-2 and EPT-10 are U/L listed as "miscellaneous door accessory". UL Listed for use on firedoors Door applications: up to 5" butt hinges —180° swing, 5'/2" butt hinges —130° swing, 6" butt hinges —110° swing, '/." butt offset pivots 180 ° swing. Not for use with swing clear hinges or center -hung pivots. Finishes SP28 (sprayed aluminum) SP313 (sprayed duranodic). Dimensions Housing 9" x 11/4" x 15/8" (229mm x 32mm x 38mm) EPT-2 Two 18 gauge wires, Up to 2 AMPS @ 24VDC, with a 16 AMPS Maximum Surge EPT-10 Ten 24 gauge wires, Up to 1 AMPS © 24VDC, with a 16 AMPS Maximum Surge PNT-1 5/32" Tubing To order, specify: 1. EPT-2 ,EPT-10 or PNT-1. 2. Finish, SP28 or SP313. E996L Electrified breakaway lever E996L Electrified lever trim provides remote locking and unlocking. Furnished standard In fall safe (FS) condition, can be field converted to fall secure (FSE) where allowed. E996L Is furnished standard with cylinder operation for nightlatch (NL) function, or with blank escutcheon (BE). Specification: solenoid — continuous duty 24VDC Solenoid draw — 0.22 amp. Power Wire Runs Through Exit Device Sod To order, specify: Power Transfer (EPT2shown) 1. Use "E" prefix, example E996L. When ordering with the exit device specify trim series with prefix "E", example 9927L -BE 3' US26D E996. 2. Device type, RN (rim/surface vertical rod/concealed vertical rod) or M (mortise). 3. RHR furnished standard if not specified, field reversible. 4. Lever style (06 lever furnished standard). Other levers, no extra charge. Control Switch (normally closed) Von Duprin 98/99 Series • 59 Mullions Removable steel mullions provide single door performance in double door openings with rim devices. Mullions are easily removed by loosening bottom set screw and removing top fitting cover. The top mullion fitting is attached to the frame and Is concealed by the fitting cover. Steel mullions are 2" (51mm) wide and 3" (76mm) deep, with a wall thickness of (3mm). Mullions are shipped with mounting screws and prepared for strikes. Strikes are not Included except where indicated. Steel mullions are available in SP28 and SP313 finishes. Consult factory for other powder coat finish options. ......71CR — Keyed removable steel •mullions make removal faster and easier bya single operation of the mortise cylinder. Once mullion is removed, large equipment or furniture can freely pass through the opening. The unit wilt self lock when re- installed. without the use of the cylinder key. Uses a 1'/:' mortise cylinder with a straight cam (Schlage caul reference 8502-191). Cylinders are sold separately. Prefix mullion model with "KR". Removable aluminum mullions are 1 (27mm) wide on face closest to the door and 2'/e" (60mm) at the widest point. The depth is 3'/." (79mm) with a wall thickness of '/e (3mm). Aluminum mullions are available in US4, US10, US28, 313 and 315 finishes. Consult factory for other powder coat finish options. Aluminum mullion are not available keyed removable. Stock hollow metal applications for devices mounted to cover ANSI 161 cutouts are higher than the standard mullion strike location. Consult the factory for special strike preparation or order a blank mullion. See below. Blank mullions are furnished without strike preparation. They are used to mount devices at a strike height different from the standard mullion preparation. To order, specify: 1. For keyed Removable option on steel mullions, prefix model number with "KR" 2. Model number 3. Height of opening 4. Finish 5. Handing If required 6. Centerline deviation (refer to device template for standard centerline) 7. Strikes, when required, should be ordered with device 16. Removable mullions Keyed removable steel mullions Steel mullions 1654 Prepared for two 1606 strikes. If 1606 strikes are not specified on the order, two per mullion will be added. Additional charges apply. 4954 Prepared for 264 or 299 strikes. For use with all Von Duprin Panic rim devices. 9954 Prepared for and must be used with two 268 strikes (88-F device), or two 499F (22-F, 98-F, 99F devices). UL fire labeled mullion for up to 3 hour opening using Von Duprin fire exit rim devices. This mullion is not easily removed due to special fittings. 98-F and 99-F devices are rated up to 10'0" (3048 mm). Note: If 268 or 499E strikes are not specified on the order. two per mullion will be added. Additional charges apply. 4754 Prepared for two 4263 monitor strikes. 4854 Prepared for one 299 and one 6111 electric strike. Indicate handing for electric strike. 9854 Prepared for one 268 or 499E strike and one 6111 electric strike. Indicate handing for electric strike. UL fire labelled mullion for up to 3 hour openings up to 8' x 8' (2438mm x 2438mm) using Von Duprin fire exit rim devices Door Fitting Cover Strike Device nDevice Top Fitting Strike Furnished with Device t Screw Hex Wrench (furnished) /.m 20 at ead Machine Screws 1.1;r -binge shown for 4764, 4654 end 4954 16 Bottsm) Bottom Fitting Anchor - Hex Wrench (furnished) 4854/9854 - Using one electric strike 299 strike 499F 288 6111 Electric Strike RHR door shown active LHR door shown inactive Von Duprin 98/99 Series • 65 PERMIT COORD COPY PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: D16-0056 DATE: 03/04/16 PROJECT NAME: THORNDYKE ELEMENTARY SCHOOL SITE ADDRESS: 4415 S 150 ST X Original Plan Submittal Revision # before Permit Issued Response to Correction Letter # Revision # after Permit Issued DEPARTMENTS: PFJ wv �I l Building Division JJs N//4- fv Public Works Ate Fire Prevention Structural -s-it-fp 1 L� ^yA- 3 s'1r0 Planning Division Permit Coordinator r PRELIMINARY REVIEW: Not Applicable n (no approval/review required) DATE: 03/08/16 Structural Review Required REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: DUE DATE: 04/05/16 Approved Corrections Required ❑ Approved with Conditions n ❑ Denied n (corrections entered in Reviews) (ie: Zoning Issues) Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire 0 Ping ❑ PW ❑ Staff Initials: 12/18/2013 FORMA CONSTRUCTION COMPANY Horne Espanol Contact Safety & Health Claims & Insurance Clik Washington State Department of Labor & Industries Page 1 of 3 A -Z index Help My L&1 Workplace Rights Trades & Licensing FORMA CONSTRUCTION COMPANY Owner or tradesperson Principals PHILLIPS, JAMES EDWARD, PRESIDENT PHILLIPS, ANDREW JAMES, VICE PRESIDENT MUNSON, JACE KELLER, SECRETARY AB SERVICE COMPANY LLC, AGENT Doing business as FORMA CONSTRUCTION COMPANY WA UBI No. 600 604 496 PO BOX 11489 OLYMPIA, WA98508-1489 360-754-5788 THURSTON County Business type Corporation Governing persons ANDREW PHILLIPS JACE K MUNSON; JAMES A PHILLIPS; License Verify the contractor's active registration / license / certification (depending on trade) and any past violations. Construction Contractor Active. Meets current requirements. License specialties GENERAL License no. FORMACC878OR Effective — expiration 09/19/2013— 09/19/2017 Bond ................. Safeco Ins Co of America Bond account no. 69S010324 $12,000.00 Received by L&I Effective date 09/19/2013 09/18/2013 Expiration date Until Canceled Insurance Wausau Underwriters Ins Co $1,000,000.00 Policy no. TB2-Z91-459645-035 Received by L&I Effective date 07/08/2015 07/09/2015 Expiration date 07/09/2016 RD\A- oic( 4yt,\ https://secure.lni.wa.gov/verify/Detail.aspx?UBI=600604496&LIC=FORMACC878OR&SAW= 3/30/2016 TUKWILA SCHOOL DISTRICT THORNDYKE ELEMENTARY SCHOOL SECURE ENTRY VESTIBULE 4415 S 150TH STREET TUKWILA, WASHINGTON 98188 PROJECT INFORMATION DRAWING INDEX PROJECT DESCRIPTION OWNER Tukwila School District 4242 South 144th Street Tukwila, Washington 98168 206.242.9097 PROJECT LOCATION Thorndyke Elementary School 4415 South 150th Street Tukwila, Washington 98188 206.901.7600 TAX PARCEL No: 0042000280 AUTHORITIES HAVING JURISDICTION City of Tukwila Department of Community Development 6300 Southcenter Blvd., #100 Tukwila, Washington 98188 building@tukwilawa.gov 206.431.3670 Fax: 206.431.3665 DESIGN TEAM ARCHITECT KMB design groups, inc. p.s. 828 -7th Avenue S.E. Olympia, Washington 98501 Jeff Feeney jefffeeney@kmbdesign.com 360.352.8883 Fax: 360.352.8853 TELECOM / SECURITY ELECTRONICS Hargis Engineers 1201 Third Avenue, Suite 600 Seattle, Washington 98101 Patrick Shannon, RCDD, MCSE, PMP - Principal patrick.shannon@hargis.biz David Bultez, RCDD, OSP - Associate david.bultez@hargis.biz 206.448.3376 Fax: 206.448.4450 CONTRACTOR FORMA Construction Company 2823 29th Ave SW # A Tumwater, Washington 98512 Lon Weaver lonw@formacc.com 360.754.5788 Fax: 360.943.5868 10161st Ave South Suite 400 Seattle, Washington 98134 DRAWING ABBREVIATIONS L 0 d AB NC ACOUS ACT ACC ADD ADJ AFF ALUM ALT APPROX ARCH BD BLDG BLK AND ANGLE AT CENTER LINE DIAMETER FOOT (FEET) INCH PENNY (NAILS) POUNDS PLATE or PROPERTY LINE ANCHOR BOLT AIR CONDITIONING ACOUSTIC(AL) ACOUSTICAL CEILING TILE ACCESSIBLE ADDITIONAL ADJACENT / ADJUSTABLE ABOVE FINISH FLOOR ALUMINUM ALTERNATE APPROXIMATE ARCHITECT(URAL) BOARD BUILDING BLOCK BLKG BM BRG BTM BTWN BUR CAB CFCI CJ CL OR 4. CLG CLR CMU COL CONC CONN CONST CONT CORR CTSK CTR DBL DEPT DF ARCHITECTURAL A0.1 COVER SHEET A0.2 REFERENCE FLOOR PLAN A2.1 FLOOR PLAN & SCHEDULES A7.1 INTERIOR ELEVATIONS, SECTIONS & DETAILS TELECOMUNICATIONS T0.1 TELECOM GENERAL NOTES, LEGEND AND SCHEDULE, T6.1 TELECOM FLOOR PLAN AND ELEVATIONS DRAWING SYMBOLS ICCDETAIL NUMBER SHEET NUMBER WHERE DETAIL APPEARS WALL SECTION DESIGNATION SHEET NUMBER WHERE SECTION APPEARS I xxx I ( =cc ) BUILDING SECTION DESIGNATION SHEET NUMBER WHERE SECTION APPEARS ELEVATION NUMBER DESIGNATION DIRECTION IN ROOM SHEET NUMBER WHERE ELEVATION APPEARS BLOCKING BEAM BEARING BOTTOM BETWEEN BUILT-UP ROOF CABINET CONTRACTOR FURNISHED/ CONTRACTOR INSTALLED CONSTRUCTION JOINT CENTER LINE CEILING CLEAR CONCRETE MASONRY UNIT COLUMN CONCRETE CONNECTION CONSTRUCTION CONTINUOUS CORRIDOR COUNTERSINK CENTER DOUBLE DEPARTMENT DRINKING FOUNTAIN ROOM NUMBER FOR FINISH SCHEDULE DOOR NUMBER FOR DOOR SCHEDULE WINDOW TYPE WINDOW NUMBER CEILING DESIGNATION CEILING HEIGHT DIA OR 0 DIAG DN DO DR DHM. DWG (E) EA EF EIFS EJ EL ELEC ELEV EN ENG EQ EQUIP ES EXP EXIST EXT FA DIAMETER DIAGONAL DOWN DITTO (REPEAT) DOOR DETENTION HOLLOW METAL DRAWING EXISTING EACH EXHAUST FAN EXTERIOR INSULATION AND FINISHING SYSTEM EXPANSION JOINT ELEVATION ELECTRICAL ELEVATION EDGE NAIL ENGINEER EQUAL EQUIPMENT EACH SIDE EXPANSION EXISTING EXTERIOR FIRE ALARM FAB FIN FDN FE FEC FF FHWS FLG FLR FOC FOM FOS FOW FP FR FRMG FRT FS FT FTG GA GALV GB GLB GWB THORNDYKE ELEMENTARY SCHOOL IS A PRE -K THROUGH 5TH GRADE SCHOOL WITH OVER 400 STUDENTS. THIS PROJECT INVOLVES INTRODUCING A NEW SECURITY SEPARATION VESIBULE FOR THE MAIN ENTRY OF THE SCHOOL. A NEW SECURE VESTIBULE WILL DIRECT VISITORS INTO THE MAIN OFFICE BEFORE ALLOWING ACCESS FURTHER INTO THE BUILDING. BUILDING OCCUPANCY CLASSIFICATION - EDUCATIONAL (GROUP E) DOOR LOCKING SEQUENCE DOOR LOCKING SEQUENCE OF OPERATIONS IS IN COMPLIANCE WITH IBC 2012 CHAPTER 10 MEANS OF EGRESS, SECTION 1008 DOORS, GATES AND TURNSTILES; 1008.1.9.8 ACCESS CONTROL EGRESS DOORS AND 1008.1.9.9 ELECTROMAGNETICALLY LOCKED EGRESS DOORS. CURRENT SEQUENCE: • EXTERIOR DOORS ARE OPEN DURING SCHOOL HOURS WITH EXISTING HARDWARE THAT HAS AN OBVIOUS METHOD OF OPERATION AND EXISTING ACCESS CONTROL DEVICE AND PANIC HARDWARE PROVIDED ON THE EGRESS SIDE THAT COMPLIES WITH SECTION 1008. PHASE I SEQUENCE: • EXISTING EXTERIOR DOORS HAVE CARD READER, MAGNETIC DOOR CONTACT AND ELECTRIC LOCK. EXTERIOR DOORS TO RECEIVE VIDEO DOOR STATION. •• DOORS SHALL HAVE AN OBVIOUS METHOD OF OPERATION FOR EGRESS AND SHALL COMPLY WITH SECTION 1008.1.9.8. AND 1008.1.9.9. • NEW INTERIOR VESTIBULE DOORS CONSTRUCTED AND PROVIDED WITH ROUGH -IN FOR PHASE 11 WORK, PANIC HARDWARE ON EGRESS SIDE AND HARDWARE ON ENTRANCE SIDE THAT COMPLIES WITH SECTION 1008. HARDWARE IN THIS PHASE IS NOT ELECTROMAGNETICALLY LOCKED. PHASE II SEQUENCE: • EXISTING EXTERIOR DOORS HAVE OPTION TO HAVE ELECTRONIC LOCK AND CARD READER / VIDEO DOOR STATION OPERATIONAL AS CONSTRUCTED IN PHASE I OR DOORS ARE OPEN AND UNLOCKED DURING SCHOOL HOURS. • NEW INTERIOR VESTIBULE DOORS WILL INCLUDE: •• DOOR HARDWARE ON ENTRANCE SIDE �• PANIC HARDWARE ON EGRESS SIDE AUTOMATIC DOOR OPERATOR WITH PUSH PLATES CARD READERS, REQUEST TO EXIT SENSOR, MAGNETIC DOOR CONTACT AND ELECTRIC LOCK ACCESS CONTROL SHALL COMPLY WITH 1008.1.9.8 AND THE ELECTROMAGNET LOCKS SHALL COMPLY WITH 1008.1.9.9. FABRICATE(ION) FINISH FOUNDATION FIRE EXTINGUISHER FIRE EXTINGUISHER CABINET FINISH FLOOR FLAT HEAD WOOD SCREW FLASHING FLOOR FACE OF CONCRETE FACE OF MASONRY FACE OF STUD FACE OF WALL FIREPROOF FIRE RESISTANT FRAMING FIRE -RETARDANT -TREATED FAR SIDE FOOT(FEET) FOOTING GAUGE GALVANIZED GRAB BAR GLUE LAMINATED BEAM GYPSUM WALLBOARD HB HC HD HDW HOSE BIBB HOLLOW CORE / HANDICAP HOLD DOWN HARDWARE HDR HEADER HGR HANGER HORIZ OR H HORIZONTAL HM HOLLOW METAL HR HTG HTR HWH HT ID IF IN INSUL INT INT JAN JST JT KIT LAT LB HOUR HEATING HEATER HOT WATER HEATER HEIGHT INSIDE DIAMETER INSIDE FACE INCH INSULATION INTERIOR INTERIOR JANITOR JOIST JOINT KITCHEN LATERAL POUNDS EXITING PLAN EXISTING EXITING: • CURRENT EXITING FOR THORNDYKE ELEMENTARY SCHOOL IS THROUGH THE MAIN LOBBY ENTRANCE/EXIT DOORS AND EXIT DOORS LOCATED AT THE ENDS OF EACH CLASSROOM WING. DIRECT EXITING TO THE EXTERIOR IS PROVIDED AT THE GYMNASIUM AND MULTI-PURPOSE ROOM. RECEPTION WILL EXIT TO THE MAIN LOBBY AND THEN TO THE EXTERIOR THROUGH THE ENTRANCEIEXIT DOORS. PROPOSED EXITING: • PROPOSED EXITING WILL FOLLOW EXISTING EXIT PATHS. EXITING IS THROUGH THE MAIN LOBBY ENTRANCE/EXIT DOORS AND EXIT DOORS LOCATED AT THE ENDS OF EACH CLASSROOM WING. DIRECT EXITING TO THE EXTERIOR IS PROVIDED AT THE GYMNASIUM AND MULTI-PURPOSE ROOM. RECEPTION WILL EXIT TO THE MAIN LOBBY VESTIBULE AND THEN TO THE EXTERIOR THROUGH THE ENTRANCE/EXIT DOORS. NOTE: EXITING ROUTE FROM BUILDING IS NOT CHANGED WITH THE ADDITION OF INTERIOR VESTIBULE DOOR. CONTRACTOR NOTES 1. FOR ANY AS -BUILT DRWING INFORMATION, CONTACT: Liliana Cardenas Director of Maintenance and Operations Tukwila School District CardenasL@tukwila.wednel.edu 206.901.8020 LF LINEAL FEET L LENGTH/LONG LOC LOCATION LT LIGHT M.C. METAL CHANNEL MR MOISTURE RESISTANT MATL MATERIAL MAX MAXIMUM MB MACHINE BOLT MECH MECHANICAL MEZZ MEZZANINE MFR MANUFACTURER MIN MINIMUM MISC MISCELLANEOUS MR MOISTURE RESISTANT MTD MOUNTED MTL METAL (N) NEW NIC NOT IN CONTRACT NO NUMBER NS NEAR SIDE NTS NOT TO SCALE OC ON CENTER OD OUTSIDE DIAMETER OF OUTSIDE FACE OFCI OWNER FURNISHED/ CONTRACTOR INSTALLED OF01 OWNER FURNISHED/ OWNER INSTALLED OVERHANG OR OVERHEAD OPENING OPPOSITE ORIENTATE(ION) PARALLEL PRECAST CONCRETE PERPENDICULAR PLASTIC LAMINATE PLATE OR PROPERTY LINE POUNDS PER SQUARE FOOT PLYWOOD POUNDS PER SQUARE INCH PRESSURE TREATED QUANTITY RADIUS REFERENCE REFLECTED REFRIGERATOR REINFORCED REQUIRED ROUND HEAD WOOD SCREW OH OPNG OPP ORNT PAR P/C PERP PLAM PL PSF PWD PSI PT QTY RAD OR R REF REFL REFR. REINF REQ'D RHWS RM ROOM RO ROUGH OPENING SC SOLID CORE SCH SCHEDULE SF SQUARE FOOT (FEET) SHT SHEET SHTG SHEATHING SIM SIMILAR SP SPACE(ING) SPS SPACES SPEC SPECIFICATIONS SQ SQUARE SS STAINLESS STEEL SSK SERVICE SINK STD STANDARD STGR STAGGER STL STEEL STR STRUCTURAL SUSP SUSPENDED(TION) SV SHEET VINYL SYM SYMMETRICAL TB TACK BOARD THK THICK TN TOE NAIL TOC TOP OF CONCRETE TOP TOM TOJ TOS TOW TPD TSCD TS TYP UBC SEATTLE NORTH REVISIONS No Changes shall be made to the scope of work without prior approval of Tukwila Cuiiding Division. °OTE: Revisions will requiro a new plan submitt and may ina:udo additional pian review foes. 1111111111111111111111 11111111111111111111 111111111111111111111 11111111111111 iuumui• 11111111111111 design groups, inc. p.s. architecture education facilities group justice facilities group security design group 906 Columbia St SW, Suite 400 Olympia, WA 98501 360.352.8883 MARK- A. tt'I-IL. Plan]:eviie/w poppy:,9.T1 i� suhj ct toerrorsand Ic: '2.f.,— 3. Appi oval of t-1-,. ( .. ... E L.'..ailnlont crit. ) noZ ()Won }f r e , 'r•. '7 ''^ t"I�YA r�� • t the v QIF,��,�, � �: �tl � L,t"i..,�;;L'=: �:, �. o of approved F ibld CPT, and Cc;nov::ir_, d: I NORTH VICINITY MAP TOP OF PAVING TOP OF MASONRY TOP OF JOIST TOP OF SHEATHING TOP OF WALL TOILET PAPER DISPENSER TOILET SEAT COVER DISPENSER TUBE STEEL TYPICAL UNIFORM BUILDING CODE UON UNLESS OTHERWISE NOTED VCT VINYL COMPOSITION TILE VERT OR V VERTICAL VIF VERIFY IN FIELD W W/ W/0 WB WC WD WIN WP WWF YD WIDE (WIDTH) WITH WITHOUT WHITE BOARD WATER CLOSET WOOD WINDOW WATER PROOF / WORK POINT WELDED WIRE FABRIC YARD APPROVALS RECEIVED CITY OF TUKWILA MAR 04 2016 PERMIT CENTER MARTIN TURNEY, EXECUTIVE DIRECTOR OF FINANCES AND OPERATIONS DATE: TUKWILA SCHOOL DISTRICT BRIAN HUTCHINSON, PRINCIPAL THORNDYKE ELEMENTARY SCHOOL DATE: SEPARATE 1 �I REQUIRED FOR: ' Me'; banica gElcctricat Plumbing j2YGas Piping Cis j of Tukwila DIVISION Date: City Of a uki :,4a BUILDING DIVISION 0wco 2 Uzi0 >Es ino cr8 imi= Is 1E2 z CZ um! Esz=1 >IMM um§" Uni g o llej F 0 >on 1.21 F 0 0 LT) ime= cl) ORIGINAL SHEET S Zj =24x36 _ HALF SIZE REDUC IONS:k xa A D FOR ,uutr UUMPLIANCE APPROVED �MAR 2 5 2�6ta REVISIONS: DATE: 02-10-2016 CONSTRUCTIO City nf" Tukwila . isb'��!'I�I' ws014.®ISIOiN SHEET NO. A0.1 3'-54" r 3'-0 60-0" PROJECT LOCATION 26'-0" .r 5.Oo r 51-6" L V 20 A5.6 t1,2u iEMPERED'HAROBOARD -- HAIN4 oT'FRCM6"AFF TO 54" AFP AT FRAMED :HALL5 OF RM 105 *._._ DL'MPSTERSNIG o.� TRANSFORMER -r1 I r I I SERVICE YARD ONC. BOLLARDS - 21'-3' „ 4'-4 LGOM!RESSOR---,4 ,8T GO'\G. HOUSEKEEPING PAD FLUID COOLER Q !, I ' • 4' ES" KIT1HE10 103$' i 6,,111* IU I .////f, '-//// EMERENGY GENERATOR A1 /�z. ///�d1 ,,,_ R.19►J _. 51026011511•7R1➢/1/lISS 919 Y,,,./ / bk 1 iii -3 , Iii -2 ..5!-&--,1,---10.-4-1 d=-1.3:.4_ --6'-8 --if-if. r 5' 6_.- 3-4 -1----.40L,02---- -4,101-7. 3-4 LOi YY ACM ---- REFER rO I/AI0 3 FOR GYM FLOOR PATTERN COVERED FLAY Air 0 4 r,i 111 Ila iI 4.44 ii 1 i ,1 ill 0• 4 4 .4 RE5 FL r-4' ITt3i 1ro 4/A10.3 5 -OR FLOOR PATTERN iv I 5'-4" 3'-4° 4,8K- 6'-4' I' -:x"'-10" 6'-4 6,-4" 3'-4".3'-4•A 4114 GYM STOR. �G-1 PLAOX. 3E3 N/A102 • v r - ENTRY HALL AT INTERI EDGE OF PERLr-INRA"/° ity r q�lFT& 10 5E3 21 426/A15 FOR LAW HALL ANCHOR 8,44r 3'-4'„ 1'-8' .3'-4 L1� GRI O, I ^A, . SaTRe lam' `l 121.1 4'"4' VBLv; n'-1 ' r- 0 23'-2" NOTE, REFER. TO A23 FCR. ENTRY LOBBY FLAN 0 CLERESTORY ENTRY HALL AT INTERIOR EOiSE OF PERLIN ABOVE. 555 DETAIL 16/A5.3 b ,_4V '-0'3'-4'2'-0 W-4" 6'-8" 8'-4'6'-8 6'-4' L 6' 4' 1 a �aE 2 1� 'PENSION X125 " 4'. 6'-0' SECOND/TN RD CLASSROOM L168_1 CLAS ROOM ALIGN HEST FACE:. EAST HALL RMS 142 AND 149 TOME 1-15 CHAP I 1 lel I liSSROOV. 1166, i D/r111R0 RI44-1 sal 12L2" .� GORRIDO t ABV ABV STAIR z\ PRE-SCHOOL '6; F_PRE-SCHOOL LIAISON \/OPP. SIM. KINDERGARTEN /2 r151-1 A1.4 GLASSROOM 12'-2° I C�� q _✓2". _I12`2k• f4 oPP• 26'-0 ,'- 5-4" ♦ 5-4' 1, 6 -0" "3'-4", T-0":_3' 47-43-4-84 26'-0' a'n a.1F10 m 26'-0" L\ l2,_l03" 2'L4'x- 8 1st PLAN 1/1611 I'-0" fpOL.dw iYP 10 BAY6 2'-5 A R C H 1 T E C T 5 1011 Western Avenue Suite No. 101 Seattle, Na 08104 F. 2Q6/340-'4511 P. 206/340-01500 O!' A1ERS REPRESENTATIVE EERY INTERNATIONAL, INC: 1326 Avenue 8th Floor Seattle, WA 416101 Phone (206) 5&1-0413 Fox (206) 581-0469 GEOTECHNICAL ENGINEER. GILES ENGINEERING ASSOC.., INC. 3607 tL Creek P ltway 50(43, Sults 102 Bothell, HA '8011 Rant) (4251 482-2020 Fax (425) 482.6300 CIVIL ENGINEER COUGHLIN PORTER LUMEN 211 Plna Street; 5u1ta 300 Seattle, HA '8101 Rana (206) 343-0460 Fat (206) 343-5641 STRUCTURAL ENGINEER ROBERT FO%ATTI ASSOCIATES 2030 First Avarua, Suns 203 Seattle, WA 48121 Mora (206) 256-1803 for (206) 256-01011 MEGHANIGAL/ELEGTRIGAL ENGINEER HARGIS ENGINEERS, INC. 600 5terurt Street, 54te 1800 Seattle, WA 416101 Moue (206) 448-3376 Fax (206) 440-4450 LANDSCAPE ARCHITECT CASCADE DESIGN COLLABORATIVE 911 Western Ave., Suite 203 Seattle, HA 98104 F(204)) 626,1133 (206) 242.8824 KITCHEN CONSULTANT Arras Design Assoclthee 350 NW 6563, Salto A Seattle, KA 98117 Ftane (206)161-111.6 Fax (206)1841124 ACOUSTICAL CONSULTANT THE 6RN5 U5CH GROUP 414 tElist Street Seattle, WA 08115 Piano (208) 524-0513 Fax (206) 524-0630 DOST CONSULTANT DAVIS LAN6DON ADAMSON 1000 Second Avenue, Suite IVO Seattle, 14A 48104 Phone (206) 343-8119 Fax (206) 343-8541 A A A\ \ GAB 02/15/01 AGGD #T1 04/14/00 RFI #238 6/20/00 RFI #24 8/I I/qq ARFI #8 1/23/51q AADDENDUM 2 5/21/Glq / ' \ ADDENDUM 1 5/14/1q REVISIONS DATE THORNDYKE ELEMENTARY SCHOOL 4415 SOUTH 150TH STREET TUKWILA, WA 48168 TUKWILA SGHOOL DISTRICT 4640 SOUTH 144TH STREET TUKWILA, HA 018168 APPROVED FOR THE OI",TiER DATE JOB NO 40186001"00 15511E DATE z -2/15/01 PRAVIN BY I MP/KK CHECKED EY :11""1 FIRST FLOOR PLAN RECEIVED CITY OF TUKWILA MAR 0 4 2016 PERMIT CENTER 1/1611 bLoosb 11 111M1111111 MEMEMEM EMEEMEE MEMEMEE design groups, inc. p.s. architecture education facilities group justice facilities group security design group 906 Columbia St SW, Suite 400 Olympia, WA 98501 360.352.8883 MAR14A, 6eAa?-0OMrI4L KM Project# E1462 tn >agn MM00 W (3i 14=ii < cs 0I C t co 2 LIU CI um! monli >nu CD I=LI g >two Um] 111'5. '2‘ 9,11 ro)it= 1=== ci) ORIGINAL SHEET SIZE = 24 x 36 HALF SIZE REDUCTIONS 9�-WE -FOR CODE COMPLIANCE APPROVED MAR 2 5 2016 REVISIONS: DATE: 02-10-2016 of Tukwila CONSTRUCTION DO MENTSNG DIVISION SHEET NO. A0.2 FINISH SCHEDULE ROOM FRAME FLOOR ASSEMBLY RATING BASE DOOR NO. NORTH WALL W EAST WALL THK. SOUTH WALL TYPE WEST WALL GLASS CEILING TYPE FIN 101A NO. NAME MAT'L FIN MAT'L HT MAT'L FIN MAT'L FIN MAT'L FIN MAT'L FIN MAT'L FIN HT NOTES ROOM 101A NEW SECURE ENTRY (E) (E) (M) (M) (E) (E) GWB P (E) (E) (E) (E) (E) (E) (E) 101A 101B ENTRY HALL (E) (E) (M) (M) (E) (E) (E) (E) (E) (E) GWB P (E) (E) (E) 101B FINISH SCHEDULE ABBREVIATIONS (E) (M) GWB EXISTING MATCH EXISTING GYPSUM WALLBOARD N/A NOT APPLICABLE P PAINT RBR CEMENT PLASTER GENERAL FINISH SCHEDULE NOTES: MATCH PAINT TO EXISTING WALL COLOR DOOR SCHEDULE DOOR FRAME HDW GROUP ASSEMBLY RATING REMARKS DOOR NO. NO. W H THK. MAT'L TYPE FIN GLASS MAT'L TYPE FIN 101A 3'-0" 7'-0" 1 3/4" ALUM A F GL1 ALUM F-1 F HW1 N PAIR 101A GL1 / GL1 \ ABBREVIATIONS (E) ALUM EXISTING ALUMINUM N FACTORY NONE 11'-0" GENERAL DOOR SCHEDULE NOTES: 1 FOR DOOR HARDWARE, REFER TO SPECIFICATIONS 2 GL1: GLAZING TO BE 1/4" THK TEMPERED GLASS 10'-8" FINISHED OPENING /% 2'-2"" 2" // 2'-11" 2" // 2'-11" /� . 21-2. 2" // _,' \ GL1 - / GL GL1 GL1 • ± 8'-71 /2" FINISHED OPENING 1, EQ. 2" 1,i" EQ. 2" 1,i, EQ. 2"1, EQ. 2" 1, 1, 1'-71 /2" ZL1 / GL1 \ GL1 ///O GL1 / / GL1 / GL1 / GL1 \ FRAME TYPE F-1 ALUMINUM STOREFRONT DOOR AND FRAME TYPES SCALE: 1/2" =1'-0" 51/2" c`o FF \ \ GL1 GL1 DOOR TYPE A ALUMINUM NOTE: FIRE SPRINKER (FS) LOCATIONS PROJECT NORTH PARTIAL REFLECTED CEILING PLAN - MAIN ENTRY SCALE: 1/4" =1'-0" NOTE: FOR FIRE SPRINKLER REFERENCE ONLY DEMO WALL BETWEEN EXISTING STUDS (VERIFY) INSTALL NEW 2x6 VERTICAL AND HORIZONTAL BLOCKING @ 24" O.0 REINSTALL EXISTING BATT INSULATION FINISH TO MATCH EXISTING PROVIDE ROUGH -IN CABLING AND COIL IN BACK BOX FOR AUTOMATIC DOOR OPERATOR PUSH PLATE; COVER WITH STAINLESS STEEL PLATE. PROVIDE ROUGH -IN FOR AUTOMATIC DOOR OPENER THIS LEAF ONLY. ALIGN FRAMING OF NEW WALL WITH EXISTING FLOOR JOINT, SEE NEW ALUMINUM STOREFRONT DOOR AND RELITES CENTER NEW DOORS TO MATCH Q. OF OLD DOORS PROVIDE ROUGH -IN CABLING FOR CARD READER; COVER WITH STAINLESS STEEL PLATE, SEE TELECOM DRAWINGS. PROJECT NORTH ENLARGED FLOOR PLAN - MAIN ENTRY SCALE: 1/2" =1'-0" PROVIDE ROUGH -IN CABLING AND COIL IN BACK BOX FOR AUTOMATIC DOOR OPERATOR PUSH PLATE; COVER WITH STAINLESS STEEL PLATE. DEMO WALL BETWEEN EXISTING STUDS (VERIFY) INSTALL NEW 2x6 VERTICAL AND HORIZONTAL BLOCKING @ 12" O.0 REINSTALL EXISTING BATT INSULATION FINISH TO MATCH EXISTING RECEIVED CITY OF TUKWILA MAR 04 2016 PERMIT CENTER D oosb MAI MI IMMO UUUURRU uui•uai 11111111111111111111111 design groups, inc. p.s. architecture education facilities group justice facilltles group security design group 906 Columbia St SW, Suite 400 Olympia, WA 98501 360.352.8883 MAKk. f . MAKPg'MIP411.. KMB Project # E1462 .1211 CD .00 Lu 00 1=1 o lansa= a3 Lu (I) Q co 2 LaLia uni >212 0 LLI g(12. w Luc)) ORIGINAL SHEET SIZE = 24 x36 HALF SIZE REDUCTIQN 11xa17 r-�!I' 1. VED FOR CODE COMPLIANCE APPROVED MAR 2 5 2016 REVISIONS: DATE: 02-10-2016 CONSTRUCTIO 121:6II DI VISI ON SHEET NO. A2 .1 10'-6" AFF (VERIFY) TOP OF EXISTING SOFFIT/ TOP OF NEW WALL 9'-0" AFF (VERIFY) BOTTOM OF SOFFIT FRAMING ±8'-71/2" AFF FINISH OPENING 7'-0" AFF DOOR HEAD FINISH FLOOR GLASS JAMB HEADER MID -HEIGHT BASE MID -HEIGHT BASE MID -HEIGHT BASE MID -HEIGHT BASE law �w V A WALL SECTIONS 400S162-54 STUD 1/4" TEMPERED GLASS, TYPICAL TRANSOM HEADER TOP RAIL 1/2" GLASS STOP, TYPICAL 51 /4" MUNTIN BAR / CROSS RAIL GLASS BASE ANCHORED TO EXISTING CONCRETE W/ SIMPSON 1/2"x 2.75" TITEN HD SCREWS SPACED @ 12" MAX. O.C. 10'-6" AFF (VERIFY) TOP OF EXISTING SOFFIT / TOP OF NEW WALL 9'-0" AFF (VERIFY) BOTTOM OF SOFFIT FRAMING ROUGH OPENING = FINISH OPENING + 5/8" ±8'-7 1/2" AFF FINISH OPENING ALIGN NEW WALL FRAMING WITH EXISTING FLOOR JOINT 51 /4" METAL CASING J -TRIM BUILT-UP TRACK AND STUD HEADER SPANNING FROM WALL TO SOFFIT 400T150-54 TRACK, TYPICAL 400S162-54 STUDS @ 12" MAX. O.C., CONTINUOUS BUILT-UP TRACK AND STUD HEADER SPANNING FROM WALL TO WALL; SECURE TRACK TO NEW BLOCKING IN SOFFIT 5/8" GWB BOTH SIDES OVER 400S162-54 STUDS @ 12" MAX. O.C. 400T150-54 BASE TRACK ANCHORED TO EXISTING CONCRETE W/ SIMPSON 112"x 2.75" TITEN HD SCREWS SPACED @ 12" MAX. O.C. LOCATE ANCHORS 3" MAX. FROM STUD AND END WALLS, TYPICAL MATCH EXISTING WOOD TRIM AND RESILIENT BASE, BOTH SIDES OF WALL SECTION EXISTING FLOOR FINISH FLOOR SCALE: 3" =1'-0" ANCHOR 400S162-54 STUD TO EACH NEW BLOCKING IN WALL AND SECURE TO CONTINUOUS BUILT-UP HEADER 5/8" GWB BOTH SIDES OVER 400S162-54 STEEL STUD FRAMING DOUBLE STUD AT DOORJAMB REMOVABLE CENTER MULLION NORTH WALL INTERIOR ELEVATION SCALE: 1/4" =1'-0" TOP OF EXISTING WALL r — NEW WALL SOUTH WALL INTERIOR ELEVATION SCALE: 1/4" =1'-0" DEMO WALL BETWEEN EXISTING STUDS (VERIFY LOCATIONS); INSTALL NEW 2x6 VERTICAL AND HORIZONTAL BLOCKING @ 12" O.C.; REINSTALL EXISTING BATT INSULATION; FINISH TO MATCH EXISTING DEMO WALL BETWEEN EXISTING STUDS (VERIFY LOCATIONS); INSTALL NEW 2x6 VERTICAL AND HORIZONTAL BLOCKING @ 12" O.C.; REINSTALL EXISTING BATT INSULATION FINISH TO MATCH EXISTING HORIZONTAL WALL SECTION SCALE: 3" = 1'-0" SECURE FRAMING TO NEW BLOCKING IN SOFFIT ABOVE ALUMINUM STOREFRONT SYSTEM WIDE STILE BEVEL EDGE DOOR 10'-8" FINISHED OPENING GLASS JAMB - GLASS POCKET ROUGH OPENING = FINISH OPENING + 1 1/4" ANCHOR 400S162-54 STUD TO EACH NEW BLOCKING IN WALL AND SECURE TO BOTH BUILT-UP HEADERS PATCH AND REPAIR EXISTING WALL AS / NECESSARY `_J DOOR OPERATOR PUSH PLATE ROUGH -IN LOCATION. DEMO EXISTING SOFFIT AS NECESSARY TO INSTALL HOR. AND VERT. 2x BLOCKING @ 12" MAX. O.C.; PATCH AND REPAIR +10'-6" AFF VERIFY TOP OF EXISTING SOFFIT / TOP OF NEW WALL +9'-0" AFF (VERIFY) BOTTOM OF SOFFIT FRAMING +7'-0" AFF DOOR HEAD RECEIVED CITY OF TUKWILA MAR 04 2016 PERMIT CENTER OPEN TO ENTRY HALL CONTINUOUS BUILT-UP HEADER SPANNING FROM WALL TO WALL NEW WALL (PAINT, BOTH SIDES) DOOR OPERATOR ROUGH -IN LOCATION (OTHER SIDE OF WALL). COVER WITH S STAINLESS STEEL PLATE. j / CARD READER ROUGH -IN LOCATION, SEE TELECOM. // 15'-0" (VERIFY) EAST NEW WALL INTERIOR ELEVATION tb- 00s1) SCALE: 1/4" = ®■■■.i■ 11111111111101111 11111111■ 1111.■■■■ 111111111111111.11 design groups, inc. p.s. architecture education facilities group Justice facilities group security design group 906 Columbia St SW, Suite 400 Olympia, WA 98501 360.352.8883 MARV— k 2AR-0.0 W4t. KMB Project# E1462 CD 00 .00 >fam 00 tiff 1=1 < Cm) 12= CZ/V Fa Tc) co 2 LLI,=1 =A >11= o Lllo is= H = z car) (Lig 1=sm Can ORIGINAL SHEET HALF SIZE REDU IZE ,. . �.O��° oNs ; J :D FR: mon ':'- , PLIANCE APPROVED REVISIONS: MAR 2 5 2016 DATE: 02-10-2016 City of Tukwila CONSTRUCTIOc'ofnil'r�SDIvlw_i.2l� SHEET NO. A7.1 (la! I!I ;II! !➢! I I! I I! 11 Ir -1 1! -! l ! I! I I! I I! 11 1 / // j 7 // // A / / / / / // // /// / /7/ // i IYIKA i / // /7/ / // /I' •NEXISTING SOFFIT NEW WALL = = - a FIRE STROBE - 1 ALARM LIGHT FIRE ALARM PANEL PATCH AND REPAIR EXISTING WALL AS /1 = SWITCH FIRE ALARM NECESSARY / ■ EXISTING CONVENIENCE OUTLET; REMOVE AND REINSTALL AS NECESSARY NORTH WALL INTERIOR ELEVATION SCALE: 1/4" =1'-0" TOP OF EXISTING WALL r — NEW WALL SOUTH WALL INTERIOR ELEVATION SCALE: 1/4" =1'-0" DEMO WALL BETWEEN EXISTING STUDS (VERIFY LOCATIONS); INSTALL NEW 2x6 VERTICAL AND HORIZONTAL BLOCKING @ 12" O.C.; REINSTALL EXISTING BATT INSULATION; FINISH TO MATCH EXISTING DEMO WALL BETWEEN EXISTING STUDS (VERIFY LOCATIONS); INSTALL NEW 2x6 VERTICAL AND HORIZONTAL BLOCKING @ 12" O.C.; REINSTALL EXISTING BATT INSULATION FINISH TO MATCH EXISTING HORIZONTAL WALL SECTION SCALE: 3" = 1'-0" SECURE FRAMING TO NEW BLOCKING IN SOFFIT ABOVE ALUMINUM STOREFRONT SYSTEM WIDE STILE BEVEL EDGE DOOR 10'-8" FINISHED OPENING GLASS JAMB - GLASS POCKET ROUGH OPENING = FINISH OPENING + 1 1/4" ANCHOR 400S162-54 STUD TO EACH NEW BLOCKING IN WALL AND SECURE TO BOTH BUILT-UP HEADERS PATCH AND REPAIR EXISTING WALL AS / NECESSARY `_J DOOR OPERATOR PUSH PLATE ROUGH -IN LOCATION. DEMO EXISTING SOFFIT AS NECESSARY TO INSTALL HOR. AND VERT. 2x BLOCKING @ 12" MAX. O.C.; PATCH AND REPAIR +10'-6" AFF VERIFY TOP OF EXISTING SOFFIT / TOP OF NEW WALL +9'-0" AFF (VERIFY) BOTTOM OF SOFFIT FRAMING +7'-0" AFF DOOR HEAD RECEIVED CITY OF TUKWILA MAR 04 2016 PERMIT CENTER OPEN TO ENTRY HALL CONTINUOUS BUILT-UP HEADER SPANNING FROM WALL TO WALL NEW WALL (PAINT, BOTH SIDES) DOOR OPERATOR ROUGH -IN LOCATION (OTHER SIDE OF WALL). COVER WITH S STAINLESS STEEL PLATE. j / CARD READER ROUGH -IN LOCATION, SEE TELECOM. // 15'-0" (VERIFY) EAST NEW WALL INTERIOR ELEVATION tb- 00s1) SCALE: 1/4" = ®■■■.i■ 11111111111101111 11111111■ 1111.■■■■ 111111111111111.11 design groups, inc. p.s. architecture education facilities group Justice facilities group security design group 906 Columbia St SW, Suite 400 Olympia, WA 98501 360.352.8883 MARV— k 2AR-0.0 W4t. KMB Project# E1462 CD 00 .00 >fam 00 tiff 1=1 < Cm) 12= CZ/V Fa Tc) co 2 LLI,=1 =A >11= o Lllo is= H = z car) (Lig 1=sm Can ORIGINAL SHEET HALF SIZE REDU IZE ,. . �.O��° oNs ; J :D FR: mon ':'- , PLIANCE APPROVED REVISIONS: MAR 2 5 2016 DATE: 02-10-2016 City of Tukwila CONSTRUCTIOc'ofnil'r�SDIvlw_i.2l� SHEET NO. A7.1 GENERAL j// EXISTING ELECTRICAL TO BE REMOVED EXISTING ELECTRICAL TO REMAIN NEW ELECTRICAL WORK — — — MATCHLINE OR PROPERTY LINE — -- - ENLARGED PLAN BOUNDARY DETAIUPLAN IDENTIFIER SECTION IDENTIFIER ELEVATION IDENTIFIER REVISION DEFINITION AREA, AREA ENCIRCLED CONTAINS CHANGES MADE SUBSEQUENT TO PREVIOUS ISSUE REVISION CALLOUT FLAG NOTE TAG O EQUIPMENT TAG EQUIPMENT TAG AHU-01 NORTH ARROW RACEWAYS AIM BOXES JUNCTION BOX PB PULL BOX XXX�) (WHERE INDICATED, SUBCRIPT INDICATES PULL BOX SIZE, ((S) = ACCESS/INTRUSION, (T) = TELECOM) ET-1XX MANHOLE (WHERE INDICATED, SUBCRIPT INDICATES MANHOLE NUMBER) (WHERE INDICATED, ARROW INDICATES COVER SIDE) HH HANDHOLE ®A FLOORBOX (SUBSCRIPT INDICATES TYPE, WHERE NO SUBSCRIPT, SEE SPECIFICATIONS) SURFACE METAL RACEWAY RACEWAY CONCEALED IN WALL OR IN CEILING (EXPOSED IN UNFINISHED AREAS) RACEWAY RUN BELOW FLOOR OR BELOW GRADE FLEXIBLE RACEWAY RACEWAY (CIRCLE DENOTES VERTICAL TRANSITION) --', RACEWAY CONTINUATION ] RACEWAY STUB WITH BUSHING [—] RACEWAY SLEEVE WITH BUSHINGS EZ -PATH FIRE STOPPING SLEEVE TM CABLE TRAY, OVERHEAD LADDER TYPE MotAdDaro -G- GROUNDING CONDUCTOR GROUND ROD GROUNDING BUSBAR EQUIPMENT GROUNDING CONNECTION L. GROUNDING STRAP SECURITY SYSTEM CRH CONTROLLER, WALL MOUNTED (CR- PROXIMITY CARD READER) (VS- VIDEO DOOR STATION) REMOTE DOOR STATION ELECTRIC LOCK REQUEST TO EXIT SENSOR Q MAGNETIC DOOR CONTACT D DR DOOR RELEASE SECURITY CABLE LABELING SCHEME HN - 02 - 00 I I 1 1 1 I SECURITY CABLE IDENTIFIER FLOOR NUMBER DEVICE IDENTIFICATION DEVICE TYPE NOT ALL SYMMS MAY APPEAR ON DRAWNGS ABBREVIATIONS ABV AFF AG AHJ AL ANSI AV AWG BAS BC BLDG BKBD C CAB CAT CATV CLG CO ABOVE ABOVE FINISHED FLOOR ABOVE GROUND AUTHORITIES HAVING JURISDICTION ASSISTIVE LISTENING AMERICAN NATIONAL STANDARD INSTITUTE AUDIO VISUAL AMERICAN WIRE GAUGE BUILDING AUTOMATION SYSTEM BONDING CONDUCTOR BUILDING BACKBOARD CONDUIT CABINET CATEGORY CABLE TELEVISION CEILING CONDUIT ONLY DEMARC DEMARCATION POINT (E) EIA EMT ENCL ER EXISTING ELECTRONIC INDUSTRIES ALLIANCE ELECTRICAL METALLIC TUBING ENCLOSURE EQUIPMENT ROOM FACP FIRE ALARM CONTROL PANEL HC HH IC IG IMC HORIZONTAL CROSS -CONNECT HAND HOLE INTERMEDIATE CROSS -CONNECT ISOLATED GROUND INTERMEDIATE METALLIC CONDUIT J -BOX JUNCTION BOX KCMIL THOUSAND CIRCULAR MILS LAN LOCAL AREA NETWORK LCP LIGHTING CONTROL PANEL MAN MAX MC MH MIN MM MPOE MPOP MNT MTD (N) NEC NIC OFC OFCI OFOI OPD OSP METROPOLITAN AREA NETWORK MAXIMUM MAIN CROSS -CONNECT MANHOLE MINIMUM MULTIMODE MAIN POINT OF ENTRANCE MAIN POINT OF PRESENCE MOUNT MOUNTED NEW NATIONAL ELECTRIC CODE NOT IN CONTRACT OPTICAL FIBER CABLE OWNER FURNISH, CONTRACTOR INSTALLED OWNER FURNISH, OWNER INSTALLED OUTSIDE PLANT DISTRIBUTION OUTSIDE PLANT PBX PRIVATE BRANCH EXCHANGE PD PANORAMIC DOME PVC POLYVINYL CHLORIDE RMFC RACK MOUNT FIBER CABINET RU RACK UNIT SM SMR SP SSP STP SW SINGLEMODE SURFACE METAL RACEWAY SERVICE PROVIDER SECURITY SYSTEM PANEL SHIELDED TWISTED PAIR SWITCH TBB TELECOMMUNICATIONS BONDING BACKBONE TEL TELEPHONE TELCO TELEPHONE COMPANY TGB TELECOMMUNICATIONS GROUNDING BUSBAR TIA TELECOMMUNICATIONS INDUSTRY ASSOCIATION TMGB TELECOMMUNICATIONS MAIN GROUNDING BUSBAR TR TELECOMMUNICATIONS ROOM TYP TYPICAL UON UPS UTP WAN WAP WP V UNLESS OTHERWISE NOTED UNINTERRUPTIBLE POWER SUPPLY UNSHIELDED TWISTED PAIR WIDE AREA NETWORK WIRELESS ACCESS POINT WEATHERPROOF VOLTS GENERAL NOTES 1. LOCATIONS OF RACEWAY, PATHWAY AND SIMILAR ITEMS ARE SHOWN SCHEMATICALLY. COORDINATE INSTALLATION, INCLUDING BUT NOT LIMITED TO CABLING, TELECOMMUNICATIONS PATHWAYS AND SPACES, AND EXACT LOCATION OF HORIZONTAL AND BACKBONE CABLING WITH LOCATIONS OF FIXED CASEWORK AND BUILDING CONDITIONS AFFECTING THE WORK OF THIS CONTRACT. 2. PERFORM WORK IN ACCORDANCE WITH APPLICABLE NATIONAL AND STATE CODES AS AMENDED LOCALLY AND ENFORCED BY THE AHJ. 3. COORDINATE SECURITY WORK WITH THAT OF OTHER TRADES. REFER TO ELECTRICAL, MECHANICAL, ARCHITECTURAL, STRUCTURAL, CIVIL, AND LANDSCAPE DRAWINGS AND SPECIFICATIONS. COORDINATION SHALL OCCUR PRIOR TO FABRICATION, PURCHASE, AND INSTALLATION OF WORK. 4. NEW CABLING INSTALLATIONS SHALL BE CONCEALED IN WALLS AND CEILINGS UNLESS OTHERWISE NOTED ON THE DRAWINGS. CABLING IN ACCESSIBLE CEILING SPACES SHALL BE INSTALLED AS OPEN CABLING NEAR STRUCTURES AND WALLS OR AS SPECIFICALLY NOTED ON DRAWINGS. SEE SPECIFICATIONS FOR SUPPORT REQUIREMENTS. 5. PROVIDE FIRESTOPPING SYSTEMS FOR CONDUIT AND RACEWAY SYSTEMS AT PENETRATIONS, SLEEVES AND SLOTS OF FIRE RATED CONSTRUCTION FOR HORIZONTAL AND INTRABUILDING PATHWAYS AND SPACES. 6. MAINTAIN A MINIMUM SPACING OF 12" FROM ELECTRICAL FEEDERS AND BRANCH CIRCUIT WIRING AND 12" FROM AUXILIARY SYSTEM CABLING. 7. MINIMUM SPACING FROM ELECTRICAL APPARATUS SUCH AS MOTOR DRIVEN EQUIPMENT AND TRANSFORMERS SHALL BE 6'-0". SPACING REQUIREMENTS SHALL APPLY TO OPEN CABLING PATHWAYS WHERE EQUIPMENT IS LOCATED ON THE SAME FLOOR, FLOOR ABOVE, FLOOR BELOW OR IN ROOMS ADJACENT TO SUCH EQUIPMENT AS THOUGH WALLS AND FLOORS DID NOT EXIST. EXCEPTION: BUILDING CONSTRUCTION THAT RESULTS IN CONTINUOUS METALLIC BARRIER BETWEEN ELECTRICAL APPARATUS AND CABLE PATHWAYS SHALL BE CONSIDERED AS SUITABLE SEPARATION. 8. PRIOR TO STARTING SECURITY INSTALLATION, CAREFULLY INSPECT INSTALLED WORK OF OTHER TRADES AND VERIFY THAT SUCH WORK IS COMPLETE TO THE POINT WHERE WORK MAY PROPERLY COMMENCE. NOTIFY THE ARCHITECT AND ENGINEER IN WRITING OF CONDITIONS DETRIMENTAL TO THE PROPER AND TIMELY COMPLETION OF THE WORK. 9. DO NOT BEGIN SECURITY INSTALLATION UNTIL ALL UNSATISFACTORY CONDITIONS ARE RESOLVED. BEGINNING WORK CONSTITUTES ACCEPTANCE OF CONDITIONS AS SATISFACTORY. 10.ROUTE CATEGORY 6 CABLES TO THEIR ASSIGNED CROSS -CONNECT. TERMINATE ALL CABLES ON 48 -PORT PATCH PANELS ON RACKS UNLESS OTHERWISE NOTED. 11.THE ELECTRICAL CONTRACTOR SHALL PROVIDE ALL CONDUIT, OUTLET BOXES, JUNCTION BOXES, RACEWAY SYSTEMS, ETC. FOR A COMPLETE AND OPERATIONAL PATHWAY SYSTEM FOR ALL TELECOMMUNICATIONS SYSTEMS PER THE SCOPE OF WORK INDICATED ON THE CONSTRUCTION DRAWINGS AND BID SPECIFICATIONS. DRA INDEX TO.1 TELECOM GENERAL NOTES, LEGEND AND SCHEDULE T6.1 TELECOM FLOOR PLAN AND ELEVATIONS LOW -VOLTAGE ROUGH -IN SCHEDULE SYMBOL MOUNTING HEIGHT DEVICE NAME OUTLET BOX CONDUIT MUD RING NOTES QTY SIZE QTY SIZE TERM LOCATION —0CR +48" CARD READER 1 4-11/16" 1 3/4" ACCESSIBLE CLG SINGLE GANG 22AWG-2C OA SHIELDED -{:krs +48" VIDEO DOOR STATION 1 SPECIALTY BACK BOX 1 1" ACCESSIBLE CLG - 2 4 DESK TOP REMOTE DOOR STATION - -- - - - 2, 3 RS 18 NO - MAGNETIC DOOR CONTACT - - 1 3/4" ACCESSIBLE CLG - 1 S - ELECTRIC LOCK - - 1 3/4" ACCESSIBLE CLG - 1 EL R TOP OF DOOR FRAME REQUEST TO EXIT SENSOR - - 1 3/4" ACCESSIBLE CLG - 1 - DOOR RELEASE BUTTON - - 1 3/4" ACCESSIBLE CLG SINGLE GANG 4 D DR GENERAL NOTE: DEVICES SHALL BE MOUNTED AS INDICATED, UON ON THE FLOOR PLANS. MOUNTING HEIGHTS INDICATED ON THE SCHEDULE REFER TO CENTER OF BACK BOX. NOTE 1: ROUTE CABLING TO LOCATION FOR FUTURE CONNECTIONS. NOTE 2: DEVICE REQUIRES NETWORK CONNECTION, PROVIDE CATEGORY 6 CABLING. NOTE 3: TERMINATE CATEGORY 6 CABLING IN EXISTING ROUGH -IN LOCATION. PROVIDE NEW FACEPLATE AND RE -TERMINATE EXISTING CABLING ON NEW MODULAR JACKS. NOTE 4: ROUTE CABLING WITH EXISTING LOW -VOLTAGE PATHWAY. PROVIDE J -BOX UNDERNEATH WORKSTATION AND COIL CABLING FOR FUTURE DEVICE INSIDE THE OUTLET BOX. CABLE LEGEND CABDLE MANUFACTURER PART NUMBER CABLE DESCRIPTION CONDUCTORS AWG SHIELD CABLE BELDEN 83656 18AWG-6C OA SHIELDED 6 18 OVERALL CMR SE-01 BELDEN 8450 22AWG-2C OA SHIELDED 2 22 OVERALL CMR SE -02 BELDEN 9940 22AWG-4C OA SHIELDED 4 22 OVERALL CMR SE -03 BELDEN 9571 18AWG-2C 2 18 NO Cli CMR SE -04 RECEIVED Y OF TUKWILA MAR 04 2016 PERMIT CENTER OCSk ME MEM MEMEME EMEMME MEEMEM MEMMEMM EMMEMME design groups, inc. p.s. architecture education facilities group justice facilities group security design group 828 -7th Avenue SE Olympia, WA 98501 360.352.8883 HARGIS Hargis Engineers, Inc. 1201 Third Avenue, Suite 600 Seattle, WA 98101 t 1206.448.3376 f 1206.448.4450 w I hargis.biz KMB Project# E1462 CO Ul 00 is= act (Si z p' 1,== um" cn orq co 2 Lu w g Lu Imum H cils) >I= um! et cin Lau 113rtcas) t/) ORIGINAL SHEET SIZF .24x36 ... HALF SIZE REDUCTIONS U '7V IED FOR CC E COMPLIANCE REVISIONS: APPROVED MAR 2 5 2016 DATE 02-10-2016 Cit Of Tukwila CONSTRUCTION �hi'.�al� SHEET NO. T0.1 PROVIDE (1)1"C TO SMB, ROUTE -FLEX GONDUI.T IN WALL UP TO OFFICE —� ACCESSIBLE CEILING SPACE DR -01-01 LOCATE AT FRONT DESK TELECOM FLOOR PLAN AND ELEVATIONS SCALE: 1/4" =11-0" RX -01-01 EL -01-01 CR -01-01 0 a • Q i PB UNSECURE ACCESS CONTROL DOOR ELEVATION - INTERIOR SCALE: NONE DETAIL NOTES: 1. DOOR ELEVATIONS ARE SHOWN FOR REFERENCE ONLY, SEE FLOOR PLANS FOR LOCATION OF SECURITY EQUIPMENT. EQUIPMENT TAGS: O MAGNETIC DPDT DOOR CONTACT (FUTURE). PROVIDE CABLING IN STORE FRONT FRAMING FOR FUTURE CONNECTIONS O2 CARD READER LOCATION. PROVIDE CABLING AND COIL IN BACK BOX WITH STAINLESS STEEL BLANK PLATE REQUEST TO EXIT LOCATION. PROVIDE CABLING IN STORE FRONT FRAMING FOR FUTURE CONNECTIONS • ELECTRIC LOCKING DOOR HARDWARE (FUTURE). PROVIDE CABLING IN STORE FRONT FRAMING FOR FUTURE CONNECTIONS • CABLING SHALL BE ROUTED TO J -BOX ABOVE CEILING IN ADMIN AREA. • ROUTE CABLING THROUGH STORE FRONT FRAMING. SHEET NOTES: 1. ALL SECURITY DEVICE CABLING ON THIS SHEET SHALL ROUTE CONTINUOUS TO AND TERMINATE AT THE ACCESS CONTROL PANEL. 2. ALL EXISTING CONDITIONS ARE TO BE MAINTAINED THROUGHOUT THE INTERIOR, EXTERIOR, EXTERIOR SITE, BUILDING ENVELOPE, ETC. IF EXISTING CONDITIONS ARE ALTERED, THE CONTRACTOR IS REQUIRED TO RETURN THE ALTERED AREA BACK TO ITS ORIGINAL STATE (OR BETTER). 3. PAINT SURFACE MOUNTED EXTERIOR CONDUITS, ETC. TO MATCH ADJACENT FINISHES. FLAG NOTES: EXISTING ACCESS CONTROL DEVICE/ DOOR HARDWARE TO REMAIN. PROVIDE (1) CATEGORY 6 CABLE TO THE ACCESS CONTROL DEVICE. TERMINATE CABLING IN THE TELECOM ROOM ON THE EXISTING PATCH PANEL. ASSUME 250' CABLE LENGTH FOR BID PURPOSES. REMOTE DOOR STATION SHALL PROVIDE MOMENTARY UNLOCK TO DOOR. PROVIDE CONNECTION FROM VIDEO STATION RELAY MODULE TO ACCESS CONTROL PANEL/ DOOR HARDWARE CONTROLLER. CONTRACTOR TO VERIFY LOCATION OF EQUIPMENT. THE EXISTING ACCESS CONTROL SYSTEM IS BY SONITROL; CONTACT KERRY GOODWIN AT (425) 754-4648 FOR INPUT/OUTPUT CONNECTIONS AND ANY ADDITIONAL PROGRAMMING OF THE ACCESS CONTROL SYSTEM. PROVIDE ROUGH -IN AND CABLING TO ELECTRIC LOCKS, DOOR POSITION SWITCHES, DOOR RELEASE AND CARD READER. ROUTE CABLING AND LEAVE 5' OF SLACK IN J -BOX ABOVE CEILING FOR FUTURE CONNECTIONS. b RECEIVED CITY OF TUKWILA MAR 04 2016 PERMIT CENTER 11111 Ell EME EMEMM MEEMME MEMMMM MEMEME design groups, inc. p.s. architecture education facilities group justice facilities group security design group 828 -7th Avenue SE Olympia, WA 98501 360.352.8883 HARGIS Hargis Engineers, Inc. 1201 Third. Avenue, Suite 600 Seattle, WA 98101 t l 206.448.3376 f l 206.448.4450 w I hargis.biz KMB Project # E1462 C") 00 ov-8 Emzi (7) C± Z LLO cie) cn w >1112 14.1 C� >an, 1.1.1 z g L41 '2' 0 0 00c1) Uzi d" ORIGINAL SHEET SIZE a 24 x 36 HALF SIZE REDUCTIONS =11 x 17 REVISIONS: REVIEWED FOR DATE 02-10-2016 CODE COMPLIANCE APPROVED MAR 2 5 2016 CONSTRUCTION 0CUMENT' `Tulmila DIVISION „ SHEET NO 1' .. n...,..,,,.,....i T6.1