HomeMy WebLinkAboutPermit D16-0079 - STENSON RESIDENCE - GARAGESTENSON GARAGE
14112 57TH(jJ S
D16-0079
Parcel No:
Address:
Project Name:
City of Tukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206-431-3670
Inspection Request Line: 206-438-9350
Web site: http://www.TukwilaWA.gov
DEVELOPMENT PERMIT
3365900775 Permit Number:
14112 57TH AVE S Issue Date:
Permit Expires On:
STENSON GARAGE
D16-0079
5/19/2016
11/15/2016
Owner:
Name:
Address:
Contact Person:
Name:
Address:
Contractor:
Name:
Address:
License No:
Lender:
Name:
Address:
STENSON FRED LEE
155 A SW 152ND STREET, BURIEN,
WA, 98166
LEE STENSON
155 SW 152 ST, BURIEN, WA, 98166
AFFIDAVIT - F. LEE STENSON
LEE STENSON
155 SW 152 ST, BURIEN, WA, 98166
Phone: (206) 423-8425
Phone:
Expiration Date:
DESCRIPTION OF WORK:
CONSTRUCT DETACHED GARAGE/SHOP.
Project Valuation: $11,784.00
Type of Fire Protection: Sprinklers: NO
Fire Alarm: NO
Type of Construction: VB
Electrical Service Provided by: TUKWILA FIRE SERVICE
Fees Collected: $557.86
Occupancy per IBC: U
Water District: TUKWILA
Sewer District: TUKWILA SEWER SERVICE
Current Codes adopted by the City of Tukwila:
International Building Code Edition:
International Residential Code Edition:
International Mechanical Code Edition:
Uniform Plumbing Code Edition:
International Fuel Gas Code:
2012
2012
2012
2012
2012
National Electrical Code:
WA Cities Electrical Code:
WAC 296-46B:
WA State Energy Code:
2014
2014
2014
2012
Public Works Activities:
Channelization/Striping:
Curb Cut/Access/Sidewalk:
Fire Loop Hydrant:
Flood Control Zone:
Hauling/Oversize Load:
Land Altering:
Landscape Irrigation:
Sanitary Side Sewer:
Sewer Main Extension:
Storm Drainage:
Street Use:
Water Main Extension:
Water Meter:
Volumes: Cut: 0 Fill: 0
Number: 0
Permit Center Authorized Signature:
Date: S —( (°1
5°"
I hearby certify that I have read and examined this permit and know the same to be true and correct. All
provisions of law and ordinances governing this work will be complied with, whether specified herein or not.
The granting of this permit does not presume to give authority to violate or cancel the provisions of any other
state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this
development permit and agree to the conditions attached to this permit.
Signature:
Print Name:
Date: 7/ /2VI
This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if
the work is suspended or abandoned for a period of 180 days from the last inspection.
PERMIT CONDITIONS:
1: ***BUILDING PERMIT CONDITIONS***
2: Work shall be installed in accordance with the approved construction documents, and any changes made
during construction that are not in accordance with the approved construction documents shall be
resubmitted for approval.
3: All permits, inspection record card and approved construction documents shall be kept at the site of work
and shall be open to inspection by the Building Inspector until final inspection approval is granted.
4: All construction shall be done in conformance with the Washington State Building Code and the
Washington State Energy Code.
5: Notify the City of Tukwila Building Division prior to placing any concrete. This procedure is in addition to
any requirements for special inspection.
6: All wood to remain in placed concrete shall be treated wood.
7: There shall be no occupancy of a building until final inspection has been completed and approved by
Tukwila building inspector. No exception.
8: All construction noise to be in compliance with Chapter 8.22 of the City of Tukwila Municipal Code. A copy
can be obtained at City Hall in the office of the City Clerk.
9: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila
Permit Center.
10: Preparation before concrete placement: Water shall be removed from place of deposit before concrete is
placed unless a tremie is to be used or unless otherwise permitted by the building official. All debris and ice
shall be removed from spaces to be occupied by concrete.
11: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an
approval of, any violation of any of the provisions of the building code or of any other ordinances of the City
of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other
ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction
documents and other data shall not prevent the Building Official from requiring the correction of errors in
the construction documents and other data.
PERMIT INSPECTIONS REQUIRED
Permit Inspection Line: (206) 438-9350
1700 BUILDING FINAL**
0301 CONCRETE SLAB
0201 FOOTING
0409 FRAMING
0606 GLAZING
0401 ROOF SHEATHING
0412 UNDERFLOOR FRAMING
0413 WALL SHEATHING/SHEAR
CITY OF TUKh
Community Development Department
Public Works Department
Permit Center
6300 Southcenter Blvd., Suite 100
Tukwila, WA 98188
http://www.TukwilaWA.gov
Building Permit No.
Project No.
Date Application Accepted:
Date Application Expires:
(a — OOT1
(For office use only)
CONSTRUCTION PERMIT APPLICATION
Applications and plans must be complete in order to be accepted for plan review.
Applications will not be accepted through the mail or by fax.
**Please Print**
SITE LOCATION
Site Address: 14112 57th ave S
Tenant Name: Lee Stenson (owner)
PROPERTY OWNER
Name: Lee Stenson
Name: Lee Stenson
City: Burien State: wa Zip: 98166
Address: 14112 57th ave south
Email: fleestenson@gmail.com
City: Tukwila State: wa
Zip: 98168
CONTACT PERSON — person receiving all project
communication
Name: Lee Stenson
Address: 155 SW 152nd St
City: Burien State: wa Zip: 98166
Phone: (206) 423-8425 Fax: (206) 241-7738
Email: fleestenson@gmail.com
GENERAL CONTRACTOR INFORMATION
Company Name: Owner
Address:
Company Name: N/A
Address: Same
Architect Name: N/A
City:
State:
Zip:
Phone:
Fax:
Phone:
Fax:
Contr Reg No.:
Email:
Exp Date:
Tukwila Business License No.:
H:\Applications\Forms-Applications On Linc\201 1 Applications\Permit Application Revised - 8-9.11.docx
Revised: August 2011
hh
King Co Assessor's Tax No.: 336590-0775
Suite Number: Floor:
New Tenant: ❑ Yes j ..No
ARCHITECT OF RECORD
Name: N/A
Address:
Company Name: N/A
—
Architect Name: N/A
Address:
City:
State:
Zip:
Phone:
Fax:
Email:
ENGINEER OF RECORD
Name: N/A
Address:
Company Name: N/A
Engineer Name:
Address:
City:
State:
Zip:
Phone:
Fax:
Email:
LENDER/BOND ISSUED (required for projects $5,000 or
greater per RCW 19.27.095)
Name: N/A
Address:
City: State: Zip:
Page 1 of 4
BUILDING PERMIT INFORMATIG 206-431-3670
Valuation of Project (contractor's bid price): $ 5,000 Existing Building Valuation: $ 400,000
Describe the scope of work (please provide detailed information):
To construct a detached work shop in rear yard slab on grade
Will there be new rack storage? ❑ Yes
®.. No If yes, a separate permit and plan submittal will be required.
Provide All Building Areas in Square Footage Below
PLANNING DIVISION:
Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches)
*For an Accessory dwelling, provide the following:
Lot Area (sq ft): 11,522 Floor area of principal dwelling: 2,250 Floor area of accessory dwelling:
*Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence.
Number of Parking Stalls Provided: Standard: 3 Compact: 0 Handicap: 0
Will there be a change in use? ❑ Yes 0 No If "yes", explain:
FIRE PROTECTION/HAZARDOUS MATERIALS:
❑ Sprinklers 0 Automatic Fire Alarm ® None 0 Other (specify)
Will there be storage or use of flammable, combustible or hazardous materials in the building? 0 Yes ❑ No
If "yes', attach list of materials and storage locations on a separate 8-1/2 " x 11" paper including quantities and Material Safety Data Sheets.
SEPTIC SYSTEM
❑ On-site Septic System — For on-site septic system, provide 2 copies of a current septic design approved by King County Health
Department.
H:\Applications\Forms-Applications On Line \2011 Applications\Permit Application Rcviscd - 8-9-11.docz
Revised: August 2011
bh
Page 2 of 4
Existing
Interior Remodel
Addition to
Existing
Structure
New
Type of
Construction per
IBC
Type of
Occupancy per
IBC
t'` Floor
560
0
0
0
ri Floor
1,900
0
0
0
3rd Floor
0
0
0
0
Floors thru
0
0
0
0
Basement
0
0
0
0
Accessory Structure*
0
0
0
240
Attached Garage
680
0
0
0
Detached Garage
0
0
0
0
Attached Carport
0
0
0
0
Detached Carport
0
0
0
0
Covered Deck
154
0
0
0
Uncovered Deck
0
0
0
0
PLANNING DIVISION:
Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches)
*For an Accessory dwelling, provide the following:
Lot Area (sq ft): 11,522 Floor area of principal dwelling: 2,250 Floor area of accessory dwelling:
*Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence.
Number of Parking Stalls Provided: Standard: 3 Compact: 0 Handicap: 0
Will there be a change in use? ❑ Yes 0 No If "yes", explain:
FIRE PROTECTION/HAZARDOUS MATERIALS:
❑ Sprinklers 0 Automatic Fire Alarm ® None 0 Other (specify)
Will there be storage or use of flammable, combustible or hazardous materials in the building? 0 Yes ❑ No
If "yes', attach list of materials and storage locations on a separate 8-1/2 " x 11" paper including quantities and Material Safety Data Sheets.
SEPTIC SYSTEM
❑ On-site Septic System — For on-site septic system, provide 2 copies of a current septic design approved by King County Health
Department.
H:\Applications\Forms-Applications On Line \2011 Applications\Permit Application Rcviscd - 8-9-11.docz
Revised: August 2011
bh
Page 2 of 4
PUBLIC WORKS PERMIT INFC - 206-433-0179
Scope of Work (please provide detailed information):
Construction of detached work shop in rear yard
Call before you Dig: 811
Please refer to Public Works Bulletin #1 for fees and estimate sheet.
Water District
...Tukwila ❑... Water District #I25
0 ...Water Availability Provided
Sewer District
® ...Tukwila
0 ...Sewer Use Certificate
❑ .. Highline
❑...Valley View ❑ .. Renton
0...Sewer Availability Provided
❑ .. Renton
❑ .. Seattle
Septic System:
❑ On-site Septic System — For on-site septic system, provide 2 copies of a current septic design approved by King County Health Department.
Submitted with Application (mark boxes which apply):
® ...Civil Plans (Maximum Paper Size — 22" x 34")
❑ ...Technical information Report (Stone Drainage) ❑ .. Geotechnical Report
0 ...Bond ❑ .. Insurance ❑ .. Easement(s) ❑ .. Maintenance Agreement(s)
❑...Traffic Impact Analysis
❑ ...Hold Harmless — (SAO)
❑ ...Hold Harmless — (ROW)
Proposed Activities (mark boxes that apply):
❑ ...Right-of-way Use - Nonprofit for less than 72 hours ❑ .. Right-of-way Use - Profit for less than 72 hours
❑ ...Right-of-way Use - No Disturbance ❑ .. Right-of-way Use — Potential Disturbance
0 ...Construction/Excavation/Fill - Right-of-way ❑
Non Right-of-way ❑
0 ...Total Cut 10 cubic yards ❑ .. Work in Flood Zone
0 ...Total Fill 10 cubic yards ❑ .. Storni Drainage
❑ ...Sanitary Side Sewer
❑ ...Cap or Remove Utilities
0 ...Frontage Improvements
❑ ...Traffic Control
❑ ...Backflow Prevention - Fire Protection
irrigation
Domestic Water
❑ .. Abandon Septic Tank
❑ .. Curb Cut
❑ .. Pavement Cut
❑ .. Looped Fire Line
❑ .. Grease Interceptor
0 .. Channelization
❑ .. Trench Excavation
0 .. Utility Undergrounding
❑ ...Permanent Water Meter Size... WO #
0 ...Temporary Water Meter Size .. WO #
❑ ...Water Only Meter Size WO # ❑ ...Deduct Water Meter Size
❑ ...Sewer Main Extension Public 0 Private 0
0 ...Water Main Extension Public 0 Private 0
FINANCE INFORMATION
Fire Line Size at Property Line Number of Public Fire Hydrant(s)
V ...Water
0 ...Sewer ❑ ...Sewage Treatment
Monthly Service Billing to:
Name: Lee Stenson Day Telephone: (206) 423-8425
Mailing Address: 155 SW 152nd St Burien wa 98166
City State Zip
Water Meter Refund/Billing:
Name: Day Telephone:
Mailing Address:
City
State Zip
H:\Applications\Forms-Applications On Line\2011 Applications\Permit Application Revised - 8-9.1 Ldocx
Revised: August 2011
bh
Page 3 of 4
PERMIT APPLICATION NOTES —
Value of Construction – In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject
to possible revision by the Permit Center to comply with current fee schedules.
Expiration of Plan Review – Applications for which no permit is issued within 180 days following the date of application shall expire by limitation.
The Building Official niay grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be
requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition).
I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER
PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT.
BUILDING OW ;R OR .% HORIZED AGENT:
Signatu;�,�
Print Name: (/2`G 77:7":-
Mailing
7
Mailing Address: ACT- S GCJ / 2 S
L\ 11:\Applications \Forms -Applications On Linc\201 I Applications \Permit Application Rcviscd - 8-9-11.docx
cvisctl: August 2011
Date: 3/2 -
Day
/ Z
Day Telephone:
City
State Zip
Page 4 of 4
Cash Register Receipt
City of Tukwila
DESCRIPTIONS
PermitTRAK
I ACCOUNT I QUANTITY
I PAID
$346.28
D16-0079 Address: 14112 57TH AVE S
Apn: 3365900775
$346.28
DEVELOPMENT
$330.00
PERMIT FEE
R000.322.100.00.00
0.00
$325.50
WASHINGTON STATE SURCHARGE
B640.237.114
0.00
$4.50
TECHNOLOGY FEE
$16.28
TECHNOLOGY FEE
TOTAL FEES PAID BY RECEIPT: R8521
R000.322.900.04.00 0.00
$16.28
$346.28
Date Paid: Thursday, May 19, 2016
Paid By: FREDERICK STENSON
Pay Method: CREDIT CARD 06482D
Printed: Thursday, May 19, 2016 2:28 PM 1 of 1
rSYSTEMS
Cash Register Receipt
City of Tukwila
DESCRIPTIONS
ACCOUNT QUANTITY PAID
PermitTRAK
$211.58
D16-0079 Address: 14112 57TH AVE S Apn: 3365900775
$211.58
DEVELOPMENT
$211.58
PLAN CHECK FEE
TOTAL FEES PAID BY RECEIPT: R8009
R000.345.830.00.00
0.00
$211.58
$211.58
Date Paid: Thursday, March 24, 2016
Paid By: STENSON FRED LEE
Pay Method: CREDIT CARD 02440D
Printed: Thursday, March 24, 2016 12:19 PM 1 of 1
erSYSTEMS
C6 INSPECTION RECORD
Retain a copy with permit
INSPECTION
Pte- 0079
PERMIT NO.
CITY OF TUKWILA BUILDING DIVISION
6300 Southcenter Blvd., #100, Tukwila. WA 98188 r (20) 431-3670
Permit Inspection Request Line (206) 438-9350 F (IA c 1
Project:
3—TENS-ON 647q/V-70
Type of Inspection:
FRAM/A/6'
Ad/J/`2 Avi
c/ i
r
Date Called:
Special Instructions:
Date Wanted:
p.m�1
Requester:
Phone No:
Approved per applicable codes. Corrections required prior to approval.
MENTS:
Inspector:
Date: y
REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be
paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection.
INSPECTION RECORD
Retain a copy with permit
INSPECTION NO. PERMIT NO.
CITY OF TUKWILA BUILDING DIVISION
6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670
Permit Inspection Request Line (206) 438-9350
Pi6-0079
Project:
Type of Innss+pection:
Address:
/q//2 57rh /410J S,
Date Called:
Special Instructions:
Date Wanted:
/-2577
a.m.
cam:
Requester:
Phone No: 2 3._
-
qz5-Zolo
pproved per applicable codes. LJ Corrections required prior to approval.
C6i'MI'MENTS:
inspector: 7-
Dater i 7
REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be
paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection.
VOAINSPECTION RECORD
Retain a copy with permit
INS ION I0N NO.
D/t - 79
PERMIT NO.
CITY OF TUKWILA BUILDING DIVISION
6300 Southcenter Blvd., #100, Tukwila. WA 98188
Permit Inspection Request Line (206) 438-9350
(206) 431-3670
Project:
-TEA/6,11Z46‘
Type of Inspection:
p ‹iiert114%A)6-
Address:
j4//l2 c?7AVE
S
Date Cat ed:
Special Instructions:
Date Want
12-
/
/��
//
/ „,
p.m.
Requester.
Phone No:
r4
Approved per applicable codes. LJ Corrections required prior to approval.
COMMENTS:
Inspector:
Date:' 2
REINSPECTION FEE REQUIRED. Prior to next inspectio. fee must be
paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection.
INSPECTION RECORD
Retain a copy with permit
INSPECTION NO. PERMIT NO.
CITY OF TUKWILA BUILDING DIVISION
6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670
Permit Inspection Request Line (206) 438-9350
bi&--6t17ci
Project: Type of Inspection:
--/61/-Ni
SC
114 LL nJ6• / 1
h2
Address://
/4'// <-?Th
Date Called:
Special Instructions:
Date Wanted: % /
Z -2z /�
p.m.
R uester:
eq
Phone No:
266 -6/Z3- X125—
Approved per applicable codes. Corrections required prior to approval.
COMMENTS:
Inspector:
Date) 2 zaJ
REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be
paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection.
\N\s
INSPECTION RECORD
Wj Retain a copy with permit
IN'T TION NO. PERMIT NO.
"V6 - 0079
CITY OF TUKWILA BUILDING DIVISION
6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670
Permit Inspection Request Line (206) 438-9350
Project:
Sprwsed OAh A -G2^
Type spection:
/Ai Q -
Address:
/y//2 5"7 774
�=
S
Date Called:
Special Instructions:
Date Wante:
// /0
//6
a.m.
p.m.
Req uestef:
Phone No:
Approved per applicable codes. Corrections required prior to approval.
COMMENTS:
Insp
ector: Am.114 Date:////0-
REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be
paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection.
PLANNING APPROVED -
No changes can be madeto these
plans without approval from the
Planninpivision of DCD
ftp: oved By:_j--
Date:
r
Ems; ; ';7 ; L. PERMIT
:aQL ! D FOR:
fiechan
cisctrical
'umbing
14,6as .. ng
City of Tukwil
Dili! D1UC DIVISION
D oz l �
5.aot
REVISIO h S
No changes shall be made to the scope
of r.fnr ‘Ifithout prior approval of
i ~vs°"ila Building Division.
NOTE: ;vv;C 13 will require a new plan submittal
1 and may incudo additional plan review fees. 1
3$
Common drive
/9.0z/y
s"b
S-0
Permit No
PI_\Poview approval is bject to errors and omissions.
A:-.;-2ro,X11 of constr ntion a )cements does not au holize
tY.
violaki of any adopter, codo or ordinance. Receipt
of approv3\ Field Copy and nditions is acknowledged:
Eye
Date. Z ' Za/
\ City of kwila
giUILDING 1 !VISION
COPY
boVo— onct
Existing
House
/ q2 ,04/
New garden/shop
r
CORRECTION
LTR#
House address
14112 57th ave S.
Legal Description
Lot #4 Block 8
Hillmans Seattle
Garden tract
parcel # 336590-0775-07
New 10' x 24' Work Shop
For Lee Stenson
Owner
206 423-8425 ....
Site
Existing house
Drive/paved area
New shop storage
11,522.04
2,250.00
230.00
240.00
REVIEWED FOR
CODE COMPLIANCE
APPROVED
MAY 1'72016
City of Tukwila
BUILDING DIVISION
square feet
square feet
square feet
square feet
RECEIVED
CITY OF TUKWILA
MAY 112016
PERMIT CENTER
NORTH 1"=20'
bl&oo7?
Composition Roof
With ridge vent
LP Lap Siding
n
East Elevation
o ►�
North Elevation
Comp Roofing
Continuous roof vent
Plate Line
6' Double door
Safety glass
3' x 2' picture
Window
Safety glass
Or
Hartie Plank lap
Siding
ate, o,
West Elevation
1/4" =
2" x 6" Fascia
9 "
1" x 4" Comer boards
South Elevation.
REVIEWED FOR
CODE COMPLIANCE
APPROVED
MAY 17 2016
City of Tukwila
BUILDING DIVISION
t(i' 00101
RECEIVED
CITY OF TUKWILA
MAY 112016
PERMIT CENTER
4"x8" ridge beam
LU 26 each end of rafter
2 x 6 rafters 24" O.C.
A-35 each end and top
2 x 4 collar ties each rafter
\ Nailed with 3-10d nails each end
Note change of
Ridge beam to 6"x10"
Collar ties to comply with
IRC802.3.1 and Table R602.3
Loft area for wood storage/drying
4" x 6" beam 4' O.C.
Decked with 2" x 6" T&G
/g
T
Wall Sheathing to be '/z" CDX
Nailed 6"O.0 to comply with
I.R.0 Table R602.3(1)
i
Double 2 x 4 top plate
2 x 4 studs 16" o.c.
1/2" CDX over nailed 6" O.0
7/16 Hartie Plank lap siding over
Approved vapor barrier
1/2" Galvanized anchor bolts
48" O.C. with 3"x3" bearing plates
2 x 4 PSI Treat plate
6" Soil separation / 1
2fr'
0 0
Li " ex s 4/441,
° 0 0 G.
-
4 Granular fill material
0 #4 rebar schedule 40
3 runs
Non -Heated area
Correction #2
Double top plate
4"x6" floor joist to rest on
4"x4" post to concrete foundation
2"x4" trimmer stud nailed to each side of
4"x4" 12" o.c. with 16d nails/4nailes
Each side to floor joists.
Double 2"x4" or 4"x4" post
2"x4" nailed each side
Where 4"x6" joist connect to header
Use LU26-2s
4"x6" beam connection
1IIf
All framing material to
Be H/Fir #2 or better to comply with I,R.0 602.2
02 /-/ —
REVIEWED FOR
CODE COMPLIANCE
APPROVED
MAY 17 2016
Ci of Tukwila
BUILD NG DIVISION
e
4" Concrete Slab
With thickened edge
RECEIVED
ITY OF TUKWILA
MAY 112016
ERMIT CENTER
Foundation Plan
1/4 = 1 '
12' 0'
Non Heated area
10' 0"
1/4 = 1'
Loft area plan
4"x6" joist H/Fir
32" oc
This area
Decked with 2"x6" T&G
/ =1'
7' fiev/3z�-
/
x 8 ridge beam
Secure hip rafters to valley
Rafters with A-35 each end
4 x 6 headers
2 x 4 jack stud each side
REVIEWED FOR
CODE COMPLIANCE
APPROVED
Double 4 x 6 Joist at loft end
With 4x4 post to ridge beam
Connected with Simpson AC 4
Post caps
2 x 6 24"o.c
With 1x4 collar ties
1/2 cdx plywood
c
BUIL
1AY172016
4 x 6 r dge beam
Or double 2x8
ity of Tukwila
DING DIVISION
A-35 each end and at ridge
Roof Plan
1/4» = 1
RECEIVED
OF TUKWILA
NAY 112016
RMIT CENTER
CCX plywood at overhang
ti1lR / 00'11
18" overhang.
Typical 4 sides
1/2' CDX Plywood nailed 6" O.0
To comply with I.R.0 Table R602.3(1)
3 1/2 " minium
Rafters nailed with 4 16d nails
And supported with Simpson LU26
1 x 8 ridgc bcam
x 6 rafters with 2 x 4 collar ties
Nailed with 3-10d nails each end
Note change of 4"x8"
Ridge beam to 6"xl0"
Continuous end to end
s1appaH 8 X 17
2X6 block riped to 4"
2.5 each rafter
H2.5 Installation
Each rafter to be nailed
With 4 16d nails -
To top plate
Wall
Note
Minium of 3 '/2 " rafter to remain with 18" over hang
Minimum of 1 '/2 " Bearing on wall plate
Not to include wall sheating
2 x 4 wall Construction
Double top Plate Minium 4' between Joints
/ / _
slap -rack g x b
4 x 8 headers
h' / 0 //F /14F/._
2 L D
REVIEWED FOR
CODE COMPLIANCE
APPROVED
MAY 1 7 2016
City of Tukwila
BUILDING DIVISION
00
te,co1G&
RECEIVED
CITY OF TUKWILA
MAY 112016
PERMIT CENTER
6"x1O"
Note ridge beam to be supported
At each end with 4" x 6" post
To foundation below
Note 3' headers below ridge to
Be 4'x 10" at south wall
4"x4" Post
LSTA24 connection
4"x4" Post
r
-ii
Simpson ABU 44
I 0
0 6
24"x 24" x 18" footing
With 4/#4 bars each way
Concrete foundation
See sheet #3
Center ridge beam support
Scale 1/2" = 1'
4"x 10" header
Double top plate
Jack stud
Trimmer stud nailed 12"o.c
With 5 16d nails to header
Pns7-
LSTA24 each side
4"X10" header
3 o
36" widow opening
REVIEWED FOR
CODE COMPLIANCE
APPROVED
MAY 17 2016
City of Tukwila
BUILDING DIVISION
RECEIVED
CITY OF TUKWILA
ate- 001
°1
MAY 112016
PERMIT CENTER
6"x10" ridge
2"x6" common and hip rafters
ti—24"o.c
H2.5 each side of valley rafters
18" overhang
Plan view 1/2" = 1'
For rafter connection see sheet #5
3' window
Safety glass
l
Elevation View 1/�" =1'
H2.5 Installation
(Nails into both lop plates)
REVIEWED FOR
CODE COMPLIANCE
APPROVED
MAY 17 2016
City of Tukwila
BUILDING DIVISION
D14100101
RECEIVED
CITY OF TUKWILA
MAY 112016
PERMIT CENTER
October 27, 2016
Lee Stenson.
14112 57th Ave S
Tukwila, WA 98168
City of Tukwila Jim Haggerton, Mayor
Department of Community Development Jack Pace, Director
RE: Request for Extension #1
Permit Number D16-0079
Dear Mr. Stenson,
This letter is in response to your written request for an extension to Permit D16-0079. The Building
Official, Jerry Hight, has reviewed your letter and considered your request to extend the above referenced
permit. It has been determined that the City of Tukwila Building Division will be granting an extension
to the permit through May 15, 2017.
If you should have any questions, please contact our office at (206) 431-3670.
Sincerely,
Bill Rambo
Permit Technician
File: Permit No. D16-0079
W.\Permit Cente/AExtension Letters\Permits\2016\D16-0079 Permit Extension in.docx
6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone 206-431-3670 • Fax 206-431-3665
Lee Stenson
155 SW 152"d Street
Suite A
Burien, WA 98166
City of Tukwila
Permit section
Building Official
Permit D 16-0079 extension
Dear Sir or Madam
I would like to request an extension of building permit No. D16-0079 for 14112 57th Ave
South. I just ran out of time doing other people's work. Planning on starting construction
Mid October.
ou for the service
Lee Stenson
1411257thAve S
Tukwila WA
98168
206 423-8425
Request for Extension #
Current Expiration. Date: 7 1
Extension Request: �j
Approved for /0 days
Denied (provide explanation)
Signature/Initials_
RECEIVED
CITY OF TUKWILA
OCT 072016
PERMIT CENTER
10/3/2016
City of Tukwila
Department of Community Development
LEE STENSON
155 SW 152 ST
BURIEN, WA 98166
RE: Permit No. D16-0079
STENSON GARAGE
14112 57TH AVE S
Dear Permit Holder:
Allan Ekberg, Mayor
Jack Pace, Director
In reviewing our current records, the above noted permit has not received a final inspection by the City of Tukwila Building
Division. Per the International Building Code, International Mechanical Code, Uniform Plumbing Code and/or the National Electric
Code, every permit issued by the Building Division under the provisions of these codes shall expire by limitation and become null
and void if the building or work authorized by such permit has not begun within 180 days from the issuance date of such permit, or if
the building or work authorized by such permit is suspended or abandoned at any time after the work has begun for a period of 180
days. Your permit will expire on 11/15/2016.
Based on the above, you are hereby advised to:
1) Call the City of Tukwila Inspection Request Line at 206-438-9350 to schedule for the next or final inspection. Each
inspection creates a new 180 day period, provided the inspection shows progress.
-or-
2) Submit a written request for permit extension to the Permit Center at least seven(7) days before it is due to expire.
Address your extension request to the Building Official and state your reason(s) for the need to extend your permit.
The Building Code does allow the Building Official to approve one extension of up to 180 days. If it is determined that your
extension request is granted, you will be notified by mail.
In the event you do not call for an inspection and/or receive an extension prior to 11/15/2016, your permit will become null and void
and any further work on the project will require a new permit and associated fees.
Thank you for your cooperation in this matter.
Sincerely,
Bill Rambo
Permit Technician
File No: D16-0079
(-3f-tj
6300 Southcenter Boulevard Suite #100 • Tukwila, Washington 98188 • Phone 206-431-3670 • Fax 206-431-3665
May 06, 2016
City of Tukwila
Department of Community Development
LEE STENSON
155 SW 152 ST
BURIEN, WA 98166
RE: Correction Letter # 2
DEVELOPMENT Permit Application Number D16-0079
STENSON GARAGE - 14112 57TH AVE S
Dear LEE STENSON,
Allan Ekberg, Mayor
Jack Pace, Director
This letter is to inform you of corrections that must be addressed before your development permit can be approved. All
correction requests from each department must be addressed at the same time and reflected on your drawings. I have
enclosed comments from the following departments:
BUILDING DEPARTMENT: Allen Johannessen at 206-433-7163 if you have questions regarding these comments.
• (GENERAL NOTE)
PLAN SUBMITTALS: (Min. size 1 lx17 to maximum size of 24x36; all sheets shall be the same size. New revised
plan sheets shall be the same size sheets as those previously submitted.)
(If applicable) "STAMP AND SIGNATURES" "Every page of a plan set must contain the seal/stamp, signature of
the licensee(s) who prepared or who had direct supervision over the preparation of the work, and date of signature.
Specifications that are prepared by or under the direct supervision of a licensee shall contain the seal/stamp,
signature of the licensee and the date of signature. If the "specifications" prepared by a licensee are a portion of a
bound specification document that contains specifications other than that of an engineering or land surveying
nature, the licensee need only seal/stamp that portion or portions of the documents for which the licensee is
responsible." It shall not be required to have each page of "specifications" (calculations) to be stamped and signed;
Front page only will be sufficient. (WAC 196-23-010 & 196-23-020)
(BUILDING REVIEW NOTES)
1. Most the information previously requested has been satisfied. One of the items that were missing is the jack -stud
under the "4x6 beam connection" (page 3). Please indicate that on the plan. Also be specific on that detail for
clarification which framing members shall be used and specify the nailing or mechanical fastener method to be
used.
2. The dormer framing shall require additional framing details for clarity. Will the roof framing extend down to the
plate line at the window or will there be a wall each side of that dormer window with rafter cut for that opening?
Any rafter framing supporting a dormer shall require additional double framing or method for supporting the
dormer framing with the new roof system. Please provide specific details to show the dormer framing where the
point loads for roof and dormer shall transfer down to the foundation.
3. The center post shown to support the ridge beam shall require more specific details with specifications where the
point loads shall transfer down to the foundation or to a center support post and footing. All point loads shall be
identified on the plan. All roof and dormer framing shall be sufficient to support a minimum 25 lb. per square foot
snow load. Provide notes with new details that support the required design loads shall meet code or provide
engineering for the roof construction. Please note that the rafters, beams and post shall be sufficient to support not
only the snow load but also the loads of what will be stored in the loft.
Please address the comments above in an itemized format with applicable revised plans, specifications, and/or other
documentation. The City requires that two (2) sets of revised plan pages, specifications and/or other documentation be
resubmitted with the appropriate revision block.
6300 Southcenter Boulevard Suite #100 • Tukwila Washington 98188 • Phone 206-431-3670 • Fax 206-431-3665
In order to better expedite your resubmittal, a 'Revision Submittal Sheet' must accompany every resubmittal. I have
enclosed one for your convenience. Corrections/revisions must be made in person and will not be accepted through the mail
or by a messenger service.
If you have any questions, I can be reached at 206-431-3655.
Sincerely,
Bill Rambo
Permit Technician
File No. D16-0079
6300 Southcenter Boulevard Suite #100 • Tukwila Washington 98188 • Phone 206-431-3670 • Fax 206-431-3665
April 05, 2016
City of Tukwila
Department of Community Development
LEE STENSON
14112 57TH AVE S
TUKWILA, WA 98188
RE: Correction Letter # 1
DEVELOPMENT Permit Application Number D16-0079
STENSON GARAGE - 14112 57TH AVE S
Dear LEE STENSON,
Allan Ekberg, Mayor
Jack Pace, Director
This letter is to inform you of corrections that must be addressed before your development permit can be approved. All
correction requests from each department must be addressed at the same time and reflected on your drawings. I have
enclosed comments from the following departments:
BUILDING DEPARTMENT: Allen Johannessen at 206-433-7163 if you have questions regarding these comments.
• (GENERAL NOTE)
PLAN SUBMITTALS: (Min. size 11x17 to maximum size of 24x36; all sheets shall be the same size. New revised
plan sheets shall be the same size sheets as those previously submitted.)
(If applicable) "STAMP AND SIGNATURES" "Every page of a plan set must contain the seal/stamp, signature of
the licensee(s) who prepared or who had direct supervision over the preparation of the work, and date of signature.
Specifications that are prepared by or under the direct supervision of a licensee shall contain the seal/stamp,
signature of the licensee and the date of signature. If the "specifications" prepared by a licensee are a portion of a
bound specification document that contains specifications other than that of an engineering or land surveying
nature, the licensee need only seal/stamp that portion or portions of the documents for which the licensee is
responsible." It shall not be required to have each page of "specifications" (calculations) to be stamped and signed;
Front page only will be sufficient. (WAC 196-23-010 & 196-23-020)
(BUILDING REVIEW NOTES)
1. The rafters are shown to attach on the outer edge of the top wall plate. Notches on cantilevered portions of rafters
are permitted provided the dimension of the remaining portion of the rafter is not less than 3-1/2 inches and the
length of the cantilever do, not exceed 24 inches. The ends of each rafter (seat cut) shall have not less than 1-1/2
inches of bearing on wood (does not include the exterior sheathing thickness). Provide elevation details of roof
framing and specify all nailing, fasteners show and specify hurricane ties to each rafter all of which shall be shown
in the elevation details (page 3). The size of rafter shall meet the minimum 3-1/2 inches width of the rafter
overhang and the required 1-1/2 inches bearing on the top plate may determine the minimum size of rafter
materials. All fastener spacing, sizing and hardware shall comply with IRC TABLE R602.3 (1).
2. Collar ties sizing and fastening shall comply with IRC R802.3.1 &
and details in addition to those already indicated.
3. Provide more specific details for the proposed loft rafters and how
show a minimum of one jack stud under the loft joist or clearly show
a mechanical fastener.
TABLE R602.3 (1). Provide notes on the plan
they are fastened, number of fasteners and
a detail of how the joist shall be supported by
4. Provide a floor plan that shows the walls with all openings shown. Specify headers and sizes at each opening.
5. Specify exterior sheathing nailing for lateral wall bracing per code. (IRC R602.1)
6300 Southcenter Boulevard Suite #100 • Tukwila Washington 98188 • Phone 206-431-3670 • Fax 206-431-3665
6. Assuming this is an un -conditioned space; provide notes on the plan non -heated un -conditioned space. If the
intent is to provide heating, energy code shall apply.
Please address the comments above in an itemized format with applicable revised plans, specifications, and/or other
documentation. The City requires that two (2) sets of revised plan pages, specifications and/or other documentation be
resubmitted with the appropriate revision block.
In order to better expedite your resubmittal, a Revision Submittal Sheet' must accompany every resubmittal. I have
enclosed one for your convenience. Corrections/revisions must be made in person and will not be accepted through the mail
or by a messenger service.
If you have any questions, I can be reached at (206)431-3655.
Sincerely,
Bill Rambo
Permit Technician
File No. D16-0079
6300 Southcenter Boulevard Suite #100 • Tukwila Washington 98188 • Phone 206-431-3670 • Fax 206-431-3665
NERNiIT COORD COPY
PLAN REVIEW/ROUTING SLIP
PERMIT NUMBER: D16-0079
PROJECT NAME: STENSON GARAGE
SITE ADDRESS: 14112 57 AVE S
Original Plan Submittal
X Response to Correction Letter # 2
DATE: 05/11/16
Revision #
Revision #
before Permit Issued
after Permit Issued
DEPARTMENTS:
s—lo—lco
Building Division
Public Works
Fire Prevention
Structural
Planning Division
nPermit Coordinator
n
1
PRELIMINARY REVIEW:
Not Applicable n
(no approval/review required)
DATE: 05/12/16
Structural Review Required
REVIEWER'S INITIALS: DATE:
APPROVALS OR CORRECTIONS: DUE DATE: 06/09/16
Approved
Corrections Required
n Approved with Conditions
n Denied
(corrections entered in Reviews) (ie: Zoning Issues)
v\a\ pelf Cs
Notation:
REVIEWER'S INITIALS:
DATE:
Permit Center Use Only
CORRECTION LETTER MAILED:
Departments issued corrections: Bldg ❑ Fire 0 Ping ❑ PW ❑ Staff Initials:
12/18/2013
PERMIT COORD COPY
PLAN REVIEW/ROUTING SLIP
PERMIT NUMBER: D16-0079
PROJECT NAME: STENSON GARAGE
SITE ADDRESS: 14112 57TH AVE S
Original Plan Submittal
DATE: 04/18/16
Revision # before Permit Issued
X Response to Correction Letter # 1 Revision # after Permit Issued
DEPARTMENTS:
c
Building Division
Public Works ❑
Fire Prevention
Structural
Planning Division
Permit Coordinator
PRELIMINARY REVIEW:
Not Applicable ❑
(no approval/review required)
REVIEWER'S INITIALS:
DATE: 04/19/16
Structural Review Required
DATE:
APPROVALS OR CORRECTIONS:
Approved
Corrections Required
(corrections entered in Reviews)
Notation:
DUE DATE: 05/17/16
Approved with Conditions ❑
Denied
(ie: Zoning Issues)
REVIEWER'S INITIALS:
DATE:
Permit Center Use Only j
CORRECTION LETTER MAILED: 5^6-1 0
Departments issued corrections: Bldg Ta-- Fire ❑ Ping ❑ PW ❑ Staff Initials:
oie
12/18/2013
PERMIT COORD COPY
PLAN REVIEW/ROUTING SLIP
PERMIT NUMBER: D16-0079 DATE: 03/26/16
PROJECT NAME: LEE STEVENSON GARAGE
SITE ADDRESS: 14112 57TH AVE S
X Original Plan Submittal
Response to Correction Letter #
Revision # before Permit Issued
Revision # after Permit Issued
DEPARTMENTS:
AT 1-k--1.11°
Building Division
ublic Wo s "'
Ayk AO- wq-lfr L.15 44)
Fire Prevention
Structural
Planning Division
❑ Permit Coordinator
El
PRELIMINARY REVIEW:
Not Applicable ❑
(no approval/review required)
REVIEWER'S INITIALS:
DATE: 03/29/16
Structural Review Required
DATE:
APPROVALS OR CORRECTIONS:
Approved
Corrections Required Denied
(corrections entered in Reviews) (ie: Zoning Issues)
Approved with Conditions
Notation:
DUE DATE: 04/26/16
REVIEWER'S INITIALS:
DATE:
Permit Center Use Only
CORRECTION LETTER MAILED: S --\ 9
Departments issued corrections: Bldg' Fire ❑ Ping ❑ PW ❑ Staff Initials:
12/18/2013
City of Tukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206-431-3670
Web site: http://www.TukwilaWA.gov
VISION'
SUBMITTAL
Revision submittals must be submitted in person at the Permit Center.
Revisions will not be accepted through the mail, fax, etc.
Date: $7// /02-o//
❑ Response to Incomplete Letter #
Response to Correction Letter # vZ
❑ Revision # after Permit is Issued
❑ Revision requested by a City Building Inspector or Plans Examiner
❑ Deferred Submittal #
Project Name: SS(�✓� �jc pj
Project Address: [i( I -4» c S
7
Contact Person: 5 v$o Phone Number: 2Q4 z3 9i2-1
Summary of Revision:
L. L oA,s
Plan Check/Permit Number: /0/ 6— G O 7 9
-# PA c- /5 3 s.t s- 7 -vi✓
3 No T7 C/Jilit/ 4 sMX,
RECEIVED
CITY OF TUKWILA
MAY 1 1 2016
PERMIT CENTER
Sheet Number(s):
"Cloud" or highlight all areas of revision include,
to of revi *o4v
Received at the City of Tukwila Permit Center by:
--Entered in TRAKiT on
W:\Permit Center\Templates \ Forms \Revision Submittal Form.doc
Revised: August 2015
City of Tukwila
REVISION
SUBMITTAL
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206-431-3670
Web site: http://www.TukwilaWA.gov
Revision .submittals must be submitted in person at the Permit Center.
Revisions will not be accepted through the mail, fax, etc.
Date: 431 zO/G
Plan Check/Permit Number: 0—/G — C 0 7 2'
Response to Incomplete Letter # __
Response to Correction Letter # /
Revision # after Permit is Issued
❑ Revision requested by a City Building Inspector or Plans Examiner
❑ Deferred Submittal #
Project Name: �' Tom- � (S' J k/
RECEIVED
CITY OF TUKWILA
APR 15 2016
PERMIT CENTER
Project Address: /L///„Z S`7 17/ . /11/
Contact Person: in /s.. .S re /✓ 4-1 Phone Number;, CSG s°1/2 6 S'11.747,-
Summary of Revision:
s / G2 v .f T A Cv 42 /i ,r; fir, D/1,7715/3 `2/4--
0 5 /* „SW 7- cs--
s,./5_
y%-
s,.F S 7 171
E.Z) Si
s/,,F 7- sy
Ai 0725 7—
Sheet Number(s):
"Cloud" or highlight all areas of revision including date of revision
Received at the City of Tukwila Permit Center by:
Entered in TR.AKiT on wk/-///�
\e:\Permit Center\Templates \Forme\Revision Submittal rorm.doc
Revised: August 2015
Au)
CITY OF TUKWILA
Department of Community Development
6300 Southcenter Boulevard, Tukwila, WA 98188
Telephone: (206) 431-367o FAX (206) 431-3665
E-mail: tukplanpci.tukwila.wa.us
Permit Center/Building Division
206 431-367o
Public Works Department
206 433-0179
Planning Division
206 431-367o
AFFIDAVIT IN LIEU OF CONTRACTOR REGISTRATION
PERMIT NO: bUo ^ 007d1
STATE OF WASHINGTON)
) ss.
COUNTY OF KING
/ l-` G %, 5C)4 , states as follows:
[please print name]
1. I have made application for a permit from the City of Tukwila, Washington.
2. I understand that state law requires that all building construction contractors be registered with the
State of Washington. The exceptions to this requirement are stated under Section 18.27.090 of the
Revised Code of Washington, a copy of which is printed on the reverse side of this Affidavit. I have
read or am familiar with RCW 18.27.090.
3. I understand that prior to issuance of a permit for work which is to be done by any contractor, the
City of Tukwila must verify either that the contractor is registered by the State of Washington, or that
one of the exemptions stated under RCW 18.27.090 applies.
4. In order to provide verification to the City of Tukwila of my compliance with this requirement, I
hereby attest that after reading the exemptions from the registration requirement of RCW 18.27.090,
I consider the work authorized under this permit to be exempt under number /% and will therefore
not be performed by a registered contractor.
5. I understand that the licensing provision of RCW 19.28.161 through 19.28.271 shall not apply to
persons making electrical installations on their own property or to regularly employed employees
working on the premises of their employer. The proposed electrical work is not for the construction
of a new building for rent, sale or lease.
I understand that I may be waiving certain rights that I might otherwise have under state law in any decision
to engage an unregistered contractor to perform construction work.
LAURIE A. WERLE
NOTARY PUBLIC
STATE OF WASHINGTON
COMMISSION EXPIRES
MAY 29, 2018
er/Owner's Agent*
Signed and sworn to before me this
d.yof
v
U
,20/Y .
NOTAY PUBLIC in and for the State of Washington
A://ft, County
l
Name as commissioned: 14 ‘t;79""Pir/
Residing at
My commission expires:
18.27.090 Exemptions. The registration provisions of this chapter do not apply to:
1. An authorized representative of the United States
government, the state of Washington, or any incorporated
city, town, county, township, irrigation district, reclamation
district, or other municipal or political corporation or
subdivision of this state;
2. Officers of a court when they are acting within the scope
of their office;
3. Public utilities operating under the regulations of the
utilities and transportation commission in construction,
maintenance, or development work incidental to their own
business;
4. Any construction, repair, or operation incidental to the
discovering or producing of petroleum or gas, or the
drilling, testing, abandoning, or other operation of any
petroleum or gas well or any surface or underground mine
or mineral deposit when performed by an owner or lessee;
5. The sale of any finished products, materials, or articles of
merchandise that are not fabricated into and do not become
a part of a structure under the common law of fixtures;
6. Any construction, alteration, improvement, or repair of
personal property performed by the registered or legal
owner, or by a mobile/manufactured home retail dealer or
manufacturer licensed under chapter 46.70 RCW who shall
warranty service and repairs under chapter 46.70 RCW;
7. Any construction, alteration, improvement, or repair
carried on within the limits and boundaries of any site or
reservation under the legal jurisdiction of the federal
government;
8. Any person who only furnished materials, supplies, or
equipment without fabricating them into, or consuming
them in the performance of, the work of the contractor;
9. Any work or operation on one undertaking or project by
one or more contracts, the aggregate contract price of
which for labor and materials and all other items is less
than five hundred dollars, such work or operations being
considered as of a casual, minor, or inconsequential nature.
The exemption prescribed in this subsection does not apply
in any instance wherein the work or construction is only a
part of a larger or major operation, whether undertaken by
the same or a different contractor, or in which a division of
the operation is made into contracts of amounts less than
five hundred dollars for the purpose of evasion of this
chapter or otherwise. The exemption prescribed in this
subsection does not apply to a person who advertises or
puts out any sign or card or other device which might
indicate to the public that he or she is a contractor, or that
he or she is qualified to engage in the business of
contractor;
10. Any construction or operation incidental to the
construction and repair of irrigation and drainage ditches
of regularly constituted irrigation districts or reclamation
districts; or to farming, dairying, agriculture, viticulture,
horticulture, or stock or poultry raising; or to clearing or
other work upon land in rural districts for fire prevention
purposes; except when any of the above work is performed
by a registered contractor;
11. An owner* who contracts for a project with a registered
contractor, except that this exemption shall not deprive the
owner of the protections of this chapter against registered
and unregistered contractors. The exemption prescribed in
this subsection does not apply to a person who performs
the activities of a contractor for the purpose of leasing or
selling improved property he or she has owned for less than
twelve months;
12.* Any person working on his or her own property,
whether occupied by him or her or not, and any person
working on his or her personal residence, whether owned
by him or her or not but this exemption shall not apply to
any person who performs the activities of a contractor on
his or her own property for the purpose of selling,
demolishing, or leasing the property;
13. An owner* who performs maintenance, repair, and
alteration work in or upon his or her own properties, or
who uses his or her own employees to do such work;
14. A licensed architect or civil or professional engineer
acting solely in his or her professional capacity, an
electrician certified under the laws of the state of
Washington, or a plumber certified under the laws of the
state of Washington or licensed by a political subdivision of
the state of Washington while operating within the
boundaries of such political subdivision. The exemption
provided in this subsection is applicable only when the
person certified is operating within the scope of his or her
certification;
15. Any person who engages in the activities herein
regulated as an employee of a registered contractor with
wages as his or her sole compensation or as an employee
with wages as his or her sole compensation;
16. Contractors on highway projects who have been
prequalified as required by RCW 47.28.070, with the
department of transportation to perform highway
construction, reconstruction, or maintenance work;
17. A mobile/manufactured home dealer or manufacturer
who subcontracts the installation, set-up, or repair work to
actively registered contractors. This exemption only applies
to the installation, set-up, or repair of the
mobile/manufactured homes that were manufactured or
sold by the mobile/manufactured home dealer or
manufacturer;
18. An entity who holds a valideleefrical''ecintra'cto'r, 's
license under chapter 19.28 RCW that employs a cer'hfied
journeyman electrician, a certified.fiesideritial specialty
electrician, or an electrical trainee meeting the
requirements of chapter 19.2.8 RCW to perform plumbing
work that is incidentally, directly, and immediately
appropriate to the like -in-kind replacement of a household
appliance or other small household utilization equipment
that requires limited electric power and limited waste
and/or water connections. An electrical trainee must be
supervised by a certified electrician while performing
plumbing work.
* Per Washington State Department of Labor and Industries lessee has