Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Permit D16-0090 - IPLAY & TALK - KIOSK RELOCATION
IPLAY AND TALK 2800 SOUTHCENTER MALL, K-0662 D16-0090 Parcel No: Address: City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-438-9350 Web site: http://www.TukwilaWA.gov DEVELOPMENT PERMIT 9202470010 Permit Number: 2800 SOUTHCENTER MALL K0662 Issue Date: Permit Expires On: Project Name: IPLAY & TALK D16-0090 4/11/2016 10/8/2016 Owner: Name: WESTFIELD PROPERTY TAX DEPT Address: PO BOX 130940 , CARLSBAD, WA, 92013 Contact Person: Name: PAUL ENGERT Address: 26990 SE 22ND WAY, SAMMAMISH, WA, 98075 Contractor: Name: J E M CONSTRUCTION INC Address: 29506 8TH AVE S , ROY, WA, 98580 License No: JEMCOI*033DD Lender: Name: WESTFIELD PROPERTY TAX DEPT Address: PO BOX 130940 , CARLSBAD, CA, 92013 Phone: (206) 225-1443 Phone: (253) 843-2765 Expiration Date: 5/15/2017 DESCRIPTION OF WORK: RELOCATION OF EXISTING KIOSK FOR IPLAY & TALK. 29'-6" WEST OF CURRENT LOCATION IN MALL CONCOURSE Project Valuation: $10,000.00 Type of Fire Protection: Sprinklers: YES Fire Alarm: YES Type of Construction: IIB Electrical Service Provided by: TUKWILA FIRE SERVICE Fees Collected: $491.22 Occupancy per IBC: M Water District: TUKWILA Sewer District: TUKWILA SEWER SERVICE Current Codes adopted by the City of Tukwila: International Building Code Edition: International Residential Code Edition: International Mechanical Code Edition: Uniform Plumbing Code Edition: International Fuel Gas Code: 2012 2012 2012 2012 2012 National Electrical Code: WA Cities Electrical Code: WAC 296-46B: WA State Energy Code: 2014 2014 2014 2012 Public Works Activities: Channelization/Striping: Curb Cut/Access/Sidewalk: Fire Loop Hydrant: Flood Control Zone: Hauling/Oversize Load: Land Altering: Landscape Irrigation: Sanitary Side Sewer: Sewer Main Extension: Storm Drainage: Street Use: Water Main Extension: Water Meter: Volumes: Cut: 0 Fill: 0 Number: 0 No Permit Center Authorized Signature: ✓l )5PL Date: L"--1 f I hearby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this development permit and agree to the conditions attached to this permit. Signature:_--��- Print Name: J rzrf�G Date: 11-41rl, This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: ***BUILDING PERMIT CONDITIONS*** 2: Work shall be installed in accordance with the approved construction documents, and any changes made during construction that are not in accordance with the approved construction documents shall be resubmitted for approval. 3: All permits, inspection record card and approved construction documents shall be kept at the site of work and shall be open to inspection by the Building Inspector until final inspection approval is granted. 4: All construction shall be done in conformance with the Washington State Building Code and the Washington State Energy Code. 5: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of this requirement. 6: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center. 7: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 8: The total number of fire extinguishers required for an ordinary hazard occupancy with Class A fire hazards is calculated at one extinguisher for each 1,500 sq. ft. of area. The extinguisher(s) should be of the "All Purpose" (3A, 40B:C) dry chemical type. Travel distance to any fire extinguisher must be 75' or less. (IFC 906.3) (NFPA 10, 5.4) 9: In order to provide you with the fastest police and fire protection under emergency conditions, please post your suite, room or apartment number in a conspicuous place near the main entry door. 10: Any overlooked hazardous condition and/or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 1700 BUILDING FINAL** 1400 FIRE FINAL CITY OF TUKWILA Community Development Department Public Works Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.TukwilaWA.gov Building Permit No. \>1(_ 00°3 D Project No. Date Application Accepted: ,3 (61 x_31-iW Date Application Expires: (For office use only) CONSTRUCTION PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **Please Print** SITE LOCATION King Co Assessor's Tax No.: 9200247-0010 Site Address: K0662 Southcenter Tukwila, WA 98188 Suite Number: Floor: First Tenant Name: iPlay & Talk PROPERTY OWNER Name: Paul Engert Name: Westfield Southcenter City: Sammamish State: WA Zip: 98075 Address: 2800 Westfield Mall Email: paul@engertarchiteture.com City: Tukwila State: WA Zip: 98188 CONTACT PERSON — person receiving all project communication Name: Paul Engert Address: 26990 SE 22nd Way City: Sammamish State: WA Zip: 98075 Phone: (206) 225-1443 Fax: Email: paul@engertarchiteture.com GENERAL CONTRACTOR INFORMATION Company Name: TBD Company Name: Ferguson Architecture Company Name: N/A Architect Name: Ben Ferguson Address: Address: 1916 S. Jefferson Street City: Tacoma State: WA City: State: Zip: Phone: Fax: Phone: Fax: Contr Reg No.: Email: Exp Date: Tukwila Business License No.: H:\Applicntions\Forms-Applications On Line\201 I Applications\Permit Application Revised - 8-9-1l.docx Revised: August 2011 bh New Tenant: ❑ Yes 0..No ARCHITECT OF RECORD Name: N/A °`l` -I ES IF-NEU) Company Name: Ferguson Architecture Company Name: N/A Architect Name: Ben Ferguson City: °- y,1F-N)I.Pk State: Address: 1916 S. Jefferson Street City: Tacoma State: WA Zip: 98401 Phone: (253) 248-6060 Fax: Email: bferguson@furgusonarch.com State: ENGINEER OF RECORD Name: N/A °`l` -I ES IF-NEU) 3OU'Mc. J Company Name: N/A wc'1x� City: °- y,1F-N)I.Pk State: Engineer Name: Address: City: State: Zip: Phone: Fax: Email: LENDER/BOND ISSUED (required for projects $5,000 or greater per RCW 19.27.095) Name: N/A °`l` -I ES IF-NEU) 3OU'Mc. J Address: 2$00 N).1 e;NNT\ 15 wc'1x� City: °- y,1F-N)I.Pk State: Zip: 9$ t1,313 Page 1 of 4 BUILDING PERMIT INFORMATION"- 2206-431-3670 Valuation of Project (contractor's bid price): $ 10,000 Describe the scope of work (please provide detailed information): Relocation of existing kiosk for iPlay & Paly 29'-6" west of current location in mall concourse Existing Building Valuation: $ Will there be new rack storage? ❑ Yes m.. No If yes, a separate permit and plan submittal will be required. Provide All Building Areas in Square Footage Below PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact: Handicap: Will there be a change in use? 0 Yes © No If "yes", explain: FIRE PROTECTION/HAZARDOUS MATERIALS: Vi Sprinklers 0 Automatic Fire Alarm 0 None 0 Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? 0 Yes iZI No If `yes', attach list of materials and storage locations on a separate 8-1/2"x 11 "paper including quantities and Material Safety Data Sheets. SEPTIC SYSTEM 0 On-site Septic System — For on-site septic system, provide 2 copies of a current septic design approved by King County Health Department. H: Applications\ Forms -Applications On Line \2011 Applications\Permit Application Revised - 8-9-11.docx Revised: August 201 I bh Page 2 of 4 Existing Interior Remodel Addition to Existing Structure New Type of Construction per IBC Type of Occupancy per IBC 1s` Floor 150 150 11-N M 2nd Floor 3rd Floor Floors thru Basement Accessory Structure* Attached Garage Detached Garage Attached Carport Detached Carport Covered Deck Uncovered Deck PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact: Handicap: Will there be a change in use? 0 Yes © No If "yes", explain: FIRE PROTECTION/HAZARDOUS MATERIALS: Vi Sprinklers 0 Automatic Fire Alarm 0 None 0 Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? 0 Yes iZI No If `yes', attach list of materials and storage locations on a separate 8-1/2"x 11 "paper including quantities and Material Safety Data Sheets. SEPTIC SYSTEM 0 On-site Septic System — For on-site septic system, provide 2 copies of a current septic design approved by King County Health Department. H: Applications\ Forms -Applications On Line \2011 Applications\Permit Application Revised - 8-9-11.docx Revised: August 201 I bh Page 2 of 4 • PUBLIC WORKS PERMIT INFORMATION — 206-433-0179 Scope of Work (please provide detailed information): Call before you Dig: 811 Please refer to Public Works Bulletin #1 for fees and estimate sheet. Water District ❑ ...Tukwila ❑ ... Water District #I25 ❑ ... Water Availability Provided Sewer District ❑ ...Tukwila ❑ ...Sewer Use Certificate ❑ .. Highline ❑ ... Valley View ❑ .. Renton ❑ ... Sewer Availability Provided ❑ .. Renton ❑ .. Seattle Septic System: ❑ On-site Septic System — For on-site septic system, provide 2 copies of a current septic design approved by King County Health Department. Submitted with Application (mark boxes which apply): ❑ ...Civil Plans (Maximum Paper Size — 22" x 34") ❑ ...Technical Information Report (Storm Drainage) 0 ...Bond ❑ .. Insurance ❑ .. Easement(s) Proposed Activities (mark boxes that apply): ❑ ...Right-of-way Use - Nonprofit for less than 72 hours ❑ ...Right-of-way Use - No Disturbance ❑ ...Construction/Excavation/Fill - Right-of-way ❑ Non Right-of-way ❑ ...Total Cut ❑ ...Total Fill ❑ ...Sanitary Side Sewer ❑ ...Cap or Remove Utilities ❑ ...Frontage Improvements ❑ ...Traffic Control ❑ ...Backflow Prevention - Fire Protection Irrigation Domestic Water cubic yards cubic yards ❑- ❑. ❑- ❑. ❑ .. Geotechnical Report ❑ .. Maintenance Agreement(s) ❑ ... Traffic Impact Analysis ❑ ...Hold Harmless — (SAO) ❑ ... Hold Harmless — (ROW) ❑ .. Right-of-way Use - Profit for less than 72 hours ❑ .. Right-of-way Use — Potential Disturbance ❑ .. Work in Flood Zone ❑ .. Storm Drainage . Abandon Septic Tank . Curb Cut . Pavement Cut . Looped Fire Line ❑ ...Permanent Water Meter Size... ❑ ...Temporary Water Meter Size .. ❑ ...Water Only Meter Size ❑ ...Sewer Main Extension Public ❑ ❑ ...Water Main Extension Public ❑ 11 51 15 51 ❑ .. Grease Interceptor ❑ .. Channelization ❑ .. Trench Excavation ❑ .. Utility Undergrounding WO # WO # WO # ❑ ...Deduct Water Meter Size Private ❑ Private ❑ FINANCE INFORMATION Fire Line Size at Property Line Number of Public Fire Hydrant(s) ❑ ...Water ❑ ...Sewer ❑ ...Sewage Treatment Monthly Service Billing to: Name: Day Telephone: Mailing Address: Water Meter Refund/Billing: Name: Mailing Address: City State Zip Day Telephone: City State Zip H:\Applications\Forms-Applications On Line \2011 Applications\Permit Application Revised - 8-9-11.docx Revised: August 2011 bh Page 3 of 4 • PERMIT APPLICATION NOTES — Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING QiV� O�IZED AGENT: Signature: Date: 03/31/2016 Print Name: Paul Engert Day Telephone: (206) 225-1443 Mailing Address: 26990 SE 22nd Way Sammamish WA 98075 CityState Zip H:\Applications\Forms-Applications On Line \2011 Applications\Permit Application Revised - 8-9-11.docx Revised: August 2011 bh Page 4 of 4 Cash Register Receipt 4 City of Tukwila DESCRIPTIONS I ACCOUNT I QUANTITY I PermitTRAK PAID $491.22 D16-0090 Address: 2800 SOUTHCENTER MALL K0662 Apn: 9202470010 $491.22 DEVELOPMENT $476.90 PERMIT FEE R000.322.100.00.00 0.00 $286.30 PLAN CHECK FEE R000.345.830.00.00 0.00 $186.10 WASHINGTON STATE SURCHARGE B640.237.114 0.00 $4.50 TECHNOLOGY FEE $14.32 TECHNOLOGY FEE TOTAL FEES PAID BY RECEIPT: R8083 R000.322.900.04.00 0.00 $14.32 $491.22 Date Paid: Thursday, March 31, 2016 Paid By: BEN FERGUSON Pay Method: CREDIT CARD 511382 Printed: Thursday, March 31, 2016 1:29 PM 1 of 1 CSYSTEMS 01111 INSPECTION RECORD Retain a copy with permit ION NO. p PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project:' ��a / Type rzction�.— : ig ///`-- / Addr s: 0Qo ca(A.“fV At.q lir ate Call 'd Special Instructions: P /f/% 0/K- # 666 2. Dat W nted: / -Jester: a.m. p.m. Reg Reqe ke' Phone N Approved per applicable codes. ElCorrections required prior to approval. COMMENTS: € f frd✓rde-�f� 7 Er / (K1 a few ✓a I pr(' r k 10(e-v4717(0P1 Inspector: ./e/ Date:,./ REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION NO. INSPECTION RECORD Retain a copy with permit PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project: �ik1 k i Type 1 spectior}: d ptct / Date Cal d: Address: � meets® -GtCfrAx't Instructions:c KITll�o6oZi/� iffSpecial Date W%anted, % �`7 —i, a.m. p.m. Requester: /// Phone No: Vii5 b06 -5 cr 7A1 LIApproved per applicable codes. IZCorrections required prior to approval. COMMENTS: r irk - % i ' v -c4/4 4 r"/C1(( rte r-e/ 0b Inspector: Date: 07176 REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. PERMIT COORD COPY PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: D16-0090 PROJECT NAME: IPLAY & TALK DATE: 03/31/16 SITE ADDRESS: 2800 SOUTHCENTER MALL - K-0662 X Original Plan Submittal Response to Correction Letter # Revision # before Permit .Issued Revision # after Permit Issued DEPARTMENTS: �S 14--14—q0 Building Division 111 ublic Wo s /I- 'arc° DS C Fire Prevention Structural Lb Ay/1- Planning yePlanning Division nPermit Coordinator m PRELIMINARY REVIEW: Not Applicable n (no approval/review required) DATE: 04/05/16 Structural Review Required REVIEWER'S INITIALS: DATE: n APPROVALS OR CORRECTIONS: Approved Corrections Required (corrections entered in Reviews) Notation: Approved with Conditions Denied (ie: Zoning Issues) DUE DATE: 05/03/16 n REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg 0 Fire ❑ Ping 0 PW 0 Staff initials: 12/18/2013 J E M CONSTRUCTION INC Home Espaiiol Contact Safety & Health 01 Washington State Deparbitent of Labor & industries Page 1 of 2 Search L&I A -Z Inc Claims & Insurance Workplace Rights J E M CONSTRUCTION INC Owner or tradesperson Principals MILLER, JAMES E, PRESIDENT Doing business as J E M CONSTRUCTION INC WA UBI No. 601 770 782 29506 8TH AVE S ROY, WA 98580 253-843-2765 PIERCE County Business type Corporation Governing persons JAMES E MILLER LORI K MILLER; License Verify the contractor's active registration / license / certification (depending on trade) and any past violations. Construction Contractor Active. Meets current requirements. License specialties GENERAL License no. JEMCOI*033DD Effective — expiration 03/04/1997— 05/15/2017 Bond CBIC Bond account no. SA7695 $12,000.00 Received by L&I Effective date 03/19/2002 03/01/2002 Expiration date Until Canceled "\k)s-611734)—(to https://secure.lni.wa.gov/verify/Detail.aspx?UBI=601770782&LIC=JEMCOI*033DD&SAW= 4/11/2016 1 2 3 4 5 ABBREVIATIONS ADJ ALT AFF ALUM ANG ANOD ACT BLDG BLK'G BM B/S CAB CIRC CLR CLG CL COL CONC CONST CONT COORD CPT CT DET DIA DIM DN DR DWG EA EL ELEC ELEV EN EQ EXIST FF FIN FLR FLUOR FOIC FTIC ADJUSTABLE / ADJACENT ALTERNATE ABOVE FINISH FLOOR ALUMINUM ANGLE ANODIZED ACOUSTICAL CEILING TILE AT BUILDING BLOCKING BEAM BUILDING STANDARD CABINET CIRCULATION CLEAR OR CLEARANCE CEILING CENTERLINE COLUMN CONCRETE CONSTRUCTION CONTINUOUS COORDINATE CARPET CERAMIC TILE DETAIL DIAMETER DIMENSION DOWN DOOR DRAWING EACH ELEVATION ELECTRIC ELEVATION OR ELEVATOR ENAMEL EQUAL EXISTING FACTORY FINISH OR FINISH FLOOR FINISH FLOOR FLUORESCENT FURNISHED BY OWNER INSTALLED BY CONTRACTOR FURNISHED BY TENANT INSTALLED BY CONTRACTOR GRAPHIC & SYMBOLS LEGEND IIIIIIII =I I II I=11 11 -111 -111 - EARTH GRAVEL/ROCK CONCRETE ASPHALT PAVING WOOD FRAMING BLOCKING OR SHIM FINISH WOOD GLASS(ELEVATION) GLASS(SECTION) GYPSUM WALL BOARD CAULKING/SEALANT //r PLYWOOD �F}f 1111 III! I • • 5A1SrS AMAMI r////// A BRICK ACOUSTIC TILE RIGID INSULATION BATT INSULATION METAL FT FTIC FURN GA GALV GL GWB HDW HM HGT HVAC IN INCAD INCL INSUL INSTL JAN JB JST JT KIT LF LTG MATL MAX MECH MED MEZZ MFR MISC MTD MTL N/A NIC NO NOM NTS FOOT/FEET FURNISHED BY TENANT INSTALLED BY CONTRACTOR FURNISH / FURNISHINGS GAUGE GALVANIZED GLASS / GLAZING GYPSUM WALL BOARD HARDWARE HOLLOW METAL HEIGHT HEATING VENTILATING AIR CONDITIONING INCH INCANDESCENT INCLUDE INSULATION INSTALLATION JANITOR JUNCTION BOX JOIST JOINT KITCHEN LINEAL FOOT LIGHTING MATERIAL MAXIMUM MECHANICAL MEDIUM MEZZANINE MANUFACTURER MISCELLANEOUS MOUNTED METAL NOT APPLICABLE NOT IN CONTRACT NUMBER NOMINAL NOT TO SCALE OFC 1024) 103 VCT 4�©D A6.1 GRID LINES ROOM NAME NUMBER DOOR NUMBER CEILING HEIGHT CEILING TYPE DATUM OR PROPERTY CORNER KEYNOTE FINISH TYPE INTERIOR ELEVATION REFERENCE ELEVATION / SECTION REFERENCE OC OPN'G OPP PERP PL PLYWD PNL PR PROP PT R RB RFGR REINF REQ'D REV RM RO SC SECT SHT SIM SM SQ STD SUSP TELE TEMP THERST TYP UNO VAR VCT VERT VWC W/ W/0 WC WD ON CENTER OPENING OPPOSITE PERPENDICULAR PLATE OR PLASTIC LAMINATE PLYWOOD PANEL PAIR PROPERTY PAINT RADIUS RESILIENT BASE REFRIGERATOR REINFORCEMENT REQUIRED REVERSE ROOM ROUGH OPENING SOLID CORE SECTION SHEET SIMILAR SHEET METAL SQUARE STANDARD SUSPENDED TELEPHONE TEMPERED THERMOSTAT TYPICAL UNLESS NOTED OTHERWISE VARIES VINYL COMPOSITION TILE VERTICAL VINYL WALL COVERING WITH WITHOUT WALL COVERING WOOD EGRESS DIRECTION EGRESS PATH ER I EGRESS DISTANCE EGRESS START POINT TA2. TA2. NORTH ARROW DETAIL REFERENCE ENLARGED DETAIL OR PLAN REFERENCE WALL TYPE REFERENCE GENERAL NOTES 1. THE CONTRACTOR SHALL BE SOLELY AND COMPLETELY RESPONSIBLE FOR CONDITIONS ON THE JOB SITE, INCLUDING THE SAFETY OF ALL PERSONS, PROPERTY, AND FOR ALL NECESSARY INDEPENDENT ENGINEERING REVIEWS OF THESE CONDITIONS, AND FOR COMPLIANCE WITH O.S.H.A. SAFETY STANDARDS. ARCHITECTS AND THEIR CONSULTANTS' JOB SITE OBSERVATIONS ARE NOT INTENDED TO INCLUDE REVIEW OF THE ADEQUACY OF THE CONTRACTOR'S SAFETY MEASURES. 2. EACH CONTRACTOR SHALL FAMILIARIZE THEMSELVES WITH ALL SPECIFIED PRODUCTS RELATING TO THEIR WORK. THEY ARE TO SUBMIT WRITTEN OBJECTIONS PRIOR TO BIDDING, IF THE CONTRACTOR HAS AN OBJECTION TO ANY PRODUCT AND/OR DISCREPANCIES BETWEEN DRAWINGS AND SPECIFICATIONS. 3. THE GENERAL CONTRACTOR SHALL VERIFY EXISTING CONDITIONS IN THE FIELD. THE ARCHITECT SHALL BE NOTIFIED IMMEDIATELY OF ANY DISCREPANCIES BETWEEN ACTUAL FIELD CONDITIONS AND CONSTRUCTION DOCUMENTS. ALL WORK THAT COULD BE EFFECTED BY THE DISCREPANCY SHALL BE HELD UNTIL SUCH DISCREPANCIES ARE RESOLVED. 4. SEPARATE PERMITS, WHEN REQUIRED AND/OR ARE DESIGN/BUILD , SHALL BE OBTAINED BY THE CONTRACTOR FOR MECHANICAL, PLUMBING, FIRE SPRINKLERS, ELECTRICAL AND FIRE ALARM. DESCRIPTIVE, DETAILED DESIGN AND SUPPLEMENTAL DOCUMENTS SHALL BE PROVIDED FOR REVIEW BY THE AUTHORITY HAVING JURISDICTION AND BY THE OWNER/TENANT/ARCHITECT FOR APPROVAL PRIOR TO ANY WORK BEING PERFORMED. 5. THE INSTALLATION OF AUTOMATIC FIRE SPRINKLER AND ALARM SYSTEMS SHALL COMPLY WITH THE INTERNATIONAL BUILDING AND FIRE CODES. 6. SPECIAL INSPECTIONS WHERE REQUIRED BY THE SCOPE OF WORK SHALL BE PERFORMED BY A APPROVED INSPECTION SERVICE APPROVED BY THE AUTHORITY HAVING JURISDICTION OR BUILDING OFFICIAL. 7. ALL WORK DONE SHALL BE IN CONFORMANCE WITH THE APPROVED PLANS AND PROJECT SPECIFICATIONS. THE APPROVED, PERMITTED, STAMPED PLANS ARE TO REMAIN ON SITE AT ALL TIMES. 8. DIMENSIONS ARE TO FINISH FACE OF GWB, CONCRETE, OR MASONRY UNLESS OR OTHER FACES UNLESS NOTES OTHERWISE. 9. DO NOT SCALE DRAWINGS; DIMENSIONS GOVERN. 10. WHEN CONSTRUCTION DETAILS ARE NOT SHOWN OR NOTED FOR ANY PART OF THE WORK, DETAILS SHALL BE THE SAME AS FOR OTHER SIMILAR WORK. IF QUESTIONS CAN NOT BE RESOLVED IN THIS MANNER, CONTACT THE ARCHITECT PRIOR TO PROCEEDING. 11. GENERAL CONTRACTOR SHALL PROVIDE OWNER WITH DETAILED CRITICAL PATH SCHEDULE FOR REVIEW AND APPROVAL PRIOR TO START OF CONSTRUCTION. UPDATES OF SCHEDULE SHALL BE MADE AS NECESSARY WITH COPIES PROVIDED TO OWNER. 12. ALL WORK AND MATERIALS SHALL BE PLACED / INSTALLED IN FULL ACCORDANCE WITH THE LATEST EDITION OF THE INTERNATIONAL BUILDING CODE IN AFFECT WITHIN THE JURISDICTION WORK IN PERFORMED AND ALL OTHER APPLICABLE STATE OR LOCAL LAWS AND REGULATIONS AS ARE APPLICABLE. NOTHING IN THESE DRAWINGS SHALL BE CONSTRUED TO PERMIT WORK WHICH IS NOT IN CONFORMANCE WITH ANY CODE OR REGULATION IN AFFECT. 13. PROTECTIVE MEASURES SHALL BE TAKEN BY THE CONTRACTOR TO PROTECT ADJACENT PROPERTY AT ALL TIMES DURING CONSTRUCTION. 14. THE CONTRACTOR SHALL COMPLY WITH ALL CURRENT APPLICABLE LOCAL ORDINANCES FOR UTILITY SERVICES. 15. LIGHT AND VENTILATION SHALL COMPLY WITH I.B.C., SECTION 1203, 1204 & 1205. 16. ALL ITEMS NOTED TO BE DEMOLISHED SHALL INCLUDE COMPLETE REMOVAL FROM SPACE AND PROPER OFF-SITE DISPOSAL OF ALL MATERIALS. 17. WHEN CHANGES TO THE MECHANICAL SYSTEM REQUIRE A MECHANICAL PERMIT THEY SHALL COMPLY WITH THE CURRENT MECHANICAL CODE, WASHINGTON STATE ENERGY CODE AND ANY LOCAL JURISDICTION REQUIREMENTS. 18. PROVIDE ILLUMINATED EXIT SIGNAGE WITH MIN. 45 MINUTES BACKUP POWER AT ALL REQUIRED EXITS. 19. PATCH AND REPAIR ALL EXISTING WALLS, FLOORS AND CEILINGS THAT ARE ADJACENT TO AND ALTERED BY NEW CONSTRUCTION. 20. CONTRACTOR IS TO COMPLY WITH CHAPTER 33 OF THE INTERNATIONAL BUILDING CODE CONCERNING PROTECTION OF PEDESTRIANS DURING CONSTRUCTION. 21. ASBESTOS AND HAZARDOUS WASTE : THE ARCHITECT HEREBY STATES, AND THE OWNER ACKNOWLEDGES, THAT THE ARCHITECT HAS NO PROFESSIONAL LIABILITY OR OTHER INSURANCE, (AND IS UNABLE TO REASONABLY OBTAIN SUCH INSURANCE) FOR CLAIMS ARISING OUT OF THE PERFORMANCE OF OR THE FAILURE TO PERFORM PROFESSIONAL SERVICES, INCLUDING BUT NOT LIMITED TO, THE PREPARATION OF REPORTS, DESIGNS, DRAWINGS, AND SPECIFICATIONS, AND RELATED TO THE INVESTIGATION DETECTION. CODE INFORMATION GOVERNING BUILDING CODES: 2012 INTERNATIONAL BUILDING CODE 2009 ICC/ANSI A117.1 (ACCESSIBILITY) 2012 UNIFORM PLUMBING CODE 2012 INTERNATIONAL MECHANICAL CODE 2014 NATIONAL ELECTRICAL CODE (NFPA 70) 2012 INTERNATIONAL ENERGY CODE W/ WASHINGTON STATE AMENDMENTS SEE SHEET TA2.1 FOR OCCUPANT ANALYSIS AND EGRESS PLAN OCCUPANCY CLASSIFICATION: M (MERCANTILE - COVERED MALL) TYPE OF CONSTRUCTION: II -N SPRINKLER SYSTEM: FULLY SPRINKLERED FIRE SEPARATION REQUIREMENTS: IBC SECTION 402.4.5.1 DOORS TO EXIT PASSAGES SHALL BE PROTECTED BE 60 MINUTE RATED DOOR AND FRAME ASSEMBLY THAT IS SELF CLOSING. EACH TENANT SPACE SHALL BE SEPARATED BY A FIRE PARTITION (60 MINUTES RATED) IN ACCORDANCE TO IBC SECTION 708. FLOOR AREAS: TENANT SPACE 150 SQ. FT. LIGHTING REQUIREMENTS SPACE IS RECONFIGURED - NO NEW LIGHTING IS PROPOSED IN THIS SCOPE OF WORK. NEW LIGHTING FIXTURES WILL BE UNDER SEPARATE FUTURE TENANT IMPROVEMENT. ENERGY REQUIREMENTS NO BUILDING ENVELOPE MODIFICATIONS ARE PROPOSED. PLUMBING FIXTURE REQ'S NOTE: PLUMBING FIXTURES ARE EXISTING; SCOPE OF WORK DOES NOT INVOLVE OCCUPANCY CHANGES OR BUILDING SQUARE FOOTAGE AMENDMENTS AND DOES NOT INCREASE FIXTURE REQUIREMENTS. DEFERRED SUBMITTALS ALL DEFERRED SUBMITTALS SHALL BE THE RESPONSIBILITY OF THE GENERAL CONTRACTOR OR HIS SUBCONTRACTORS. HE / THEY ARE RESPONSIBLE FOR ALL PERMIT COSTS AND PERMITTING OF SAME. ELECTRICAL SYSTEMS .:-;.., „ : TL- PERMIT REQUiRED FOR: y echanical g<lectrlcal E j mbing 1.rrGas Piping C iy of Tukwila `:l);'.1".% { DIVISION REVISIONS No changes shall be made to the scope of work without prior approval of 'uiviila Building Division. N : I•; vv:;;; ::s will require a new plan submittal and may include additional plan review fees. WESTFIELD SOUTHCENTER MALL NORDSTROM macys SEARS r* PROJECT DIRECTORY ARCHITECT/CONTACT: OWNER: GENERAL CONTRACTOR: TAX PARCEL # 920247-0010 FERGUSON ARCHITECTURE 1916 JEFFERSON STREET TACOMA, WASHINGTON 98401 CONTACT: PAUL ENGERT PHONE: (206) 225-1443 EMAIL: paul@engertarchitecture.com WESTFIELD SOUTHCENTER 2800 WESTFIELD MALL TUKWILA, WASHINGTON 98188 CONTACT: PHONE: EMAIL: TBD LEGAL DESCRIPTION WAYNE JOHNSON 714-3485 wjohnson@us.westfield.com WEA SOUTHCENTER LLC BSIP PER BSIP REC VOL 256 PGS 1-9 WHICH REPLACES BSIP REC VOL 249 PGS 77-84 (AKA PARCEL A TUKWILA BSIP #L10-032 REC #20101021000765) ADDRESS K0662 SOUTHCENTER TUKWILA, WA 98188 PROJECT DESCRIPTION RELOCATE EXISTING KIOSK 29'-6" TO THE WEST OF CURRENT LOCATION AND INSTALL NEW FLOOR FLOORING . INDEX OF DRAWINGS TA1.0 TA2.1 TA2.2 PROJECT REAM, INDEX & CODE INFORMATION FLOOR PLAN EXISTING KIOSK PHOTOGRAPHS FILE COPY Permit No. Flan review approval is subject to errors and on ce-lcn$. k prove! of consfr. tion documents does riot auta; o id. the violation r ;' any adopted code or ordinance. of approved Field Copy and conditions is acknowledged: By: � Date: - - / I -1 City of Tukwila BUILDING DIVISION 11:111wimiu • r Iii ■ enney OVERALL MALL PLAN WED FOR 0CDE,CC PLIANCE •`. APPROVED APR 0 7 2016 A--•5 U� .City of Tukwila' BUILDING DIVISION AREA OF WORK CITY OF TU KW� `? A MAR 31 2016 PERMIT CENTER b I --- 0 0�o A 1017 U x U Tal E 0 (1)0)coL O ¢ N C Ey • CO ▪ U • O P2 f/)C 4 o C-17) REGISTE ECT B DAV TATE 0` U•ON SHINGTON o B 0 00 cjW 00 00 01) Ol Q LLI Q 0.)I--- W U F- < Z = O t(, fV a: LD LIDCD >12 Is= C innJ .22 REVISIONS: DATE: PROJECT NO: PRINCIPAL -IN -CHARGE: PROJECT MANAGER: DRAWN BY: 0313112016 009-02-16 BEN PAUL PAUL PHASE / DELIVERABLE: ° PERMIT SET 1 2 3 4 5 SHEET TITLE: PROJECT TEAM INDEX CODE INFORMATION SHEET NO. TA1.0 1 2 3 4 5 PACIFIC SUNWEAR LEASE LINE 15' LEAS -0" LINE a ANN TAYLOR LOFT 29'-6"± VFY. W/ WESTFIELD oM LEASE LINE LLI O W Q -J O 9 O iPLAY & TALK RELOCATED KIOSK LEASE LINE E ABERCROMBIE & FITCH LEASE LINE O I—_ I 166 L_ I L {, I 1 L_ BUCKLE 0 ‚II, FLOOR PLAN 1/4" =11-0" SEE SHEET TA2.2 FOR PHOTOGRAPHS OF EXISTING KIOSK TO BE RELOCATED KEY NOTES 1. REMOVE AND DISPOSE EXISTING RUBBER MATT FLOORING INCLUDING BUT NOT LIMITED TO: ADHESIVES, TRANSITION STRIP, ETC. FLOOR TILE SHALL BE FREE OF ALL DEBRIS. 2. EXISTING KIOSK CASEWORK TO BE RELOCATED TO THE WEST APPROXIMATELY 29'-6" 3. RELOCATED KIOSK CASEWORK. 4. INSTALL NEW WOOD FLOORING WITH ALUMINUM TRANSITION STRIP AT ALL EDGES. WOOD FLOORING TO BE MANNINGTON ANTIGUA 7" WHITE OAK OR APPROVED EQUAL. 5. POWER AND DATA SHALL BE EXTENDED TO THE NEW LOCATION. ELECTRICAL SCOPE SHALL BE UNDER SEPARATE PERMIT. KAWED FOR WE COMPLIANCE APPROVED APR 0 7 201 Cid of Tukwila B1 lLOI{'<ZG OIV[StON RECEIVED CITY OF o'UKWILA MAR 31 20 16 PERMIT CENTER V 0 o U U) 0) . O > N ca f2 g a) (d N N 0 d EP �) cow O J Q a 00 ==i �W 00 GC � Fzizi Z 0 0 a - mmg v) � w 1== 0 a Z to <ZFzirzi kr)'' �o H Q J ■22 REVISIONS: DATE: 03/31/2016 PROJECT NO: PRINCIPAL -IN -CHARGE: PROJECT MANAGER: DRAWN BY: 009.02-16 BEN PAUL PAUL PHASE / DELIVERABLE: D PERMIT SET SHEET TITLE: FLOOR PLAN PHOTOS SHEET NO. TA2.1 1 2 3 4 C 2 3 4 5 RELOCATION OF KIOKS MOVE KIOSK 29'-6" TO THE WEST FROM ORIGINAL POSITION AND INSTALL NEW WOOD FLOORING IN LIEU RUBBER MAT FLOORING. REGI `+' D CHIT 'CT B DA j '' GUSON TATE ,+ SHINGTON EXISTING KIOSK LOCATION NEW KIOSK LOCATION 10' X 15` LEASE LINE B A RELOCATION IMAGE EAST ELEVATION - EXISTING CASEWORK WEST ELEVATION - EXISTING CASEWORK Apr, rWiwounweiMANNie 00 00 SI 00 01 J_ F CC LU U F- 0 0 cn fV O 4,107/6.. REVISIONS: 2 NORTH ELEVATION - EXISTING CASEWORK 3 4 SOUTH ELEVATION - EXISTING CASEWORK WED FOR COMPLIANCE APPROVED APR 0 7 2016 i of Tukwila LUNG DIVISION r .E CFIVED CITY OF ILI KVil MAR 31 2016 PERMIT CENTE DATE: 03131/2016 PROJECT NO: 009-02-16 PRINCIPAL -IN -CHARGE: BEN PROJECT MANAGER: PAUL DRAWN BY: PAUL PHASE / DELIVERABLE: ° PERMIT SET SHEET TITLE: EXISTING KIOSK PHOTOS SHEET NO.