Loading...
HomeMy WebLinkAboutPermit D16-0110 - HARTUNG GLASS - BLOWER ROOMHARTUNG GLASS 17750 W VALLEY HWY EXPIRED 02/06/18 D16-0110 Parcel No: Address: City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-438-9350 Web site: http://www.TukwilaWA.gov DEVELOPMENT PERMIT 3623049097 Permit Number: 17750 W VALLEY HWY Issue Date: Permit Expires On: Project Name: HARTUNG GLASS D16-0110 6/20/2016 12/20/2016 Owner: Name: Address: Contact Person: Name: Address: Contractor: Name: Address: License No: Lender: Name: Address: SCIOLA FAMILY PROPERTIES LL 17830 W VALLEY HWY, TUKWILA, WA, 98188 TORJAN RONHOVDE 14900 INTERURBAN AVE S , TUKWILA, WA, 98168 GATEWAY CONSTRUCTION SVS 5602 2ND AVE S , SEATTLE, WA, 98108-2409 GATEWCS992C3 I1I Phone: (206) 859-5500 Phone: (206) 621-9111 Expiration Date: 3/4/2018 DESCRIPTION OF WORK: PROVIDE A 460 SF BLOWER ROOM WITHIN AN EXISTING GLASS MANUFACTURING FACILITY. Project Valuation: $20,000.00 Type of Fire Protection: Sprinklers: YES Fire Alarm: YES Type of Construction: VB Electrical Service Provided by: TUKWILA Fees Collected: $890.92 Occupancy per IBC: F-1 Water District: RENTON Sewer District: RENTON Current Codes adopted by the City of Tukwila: International Building Code Edition: International Residential Code Edition: International Mechanical Code Edition: Uniform Plumbing Code Edition: International Fuel Gas Code: 2012 2012 2012 2012 2012 National Electrical Code: WA Cities Electrical Code: WAC 296-46B: WA State Energy Code: 2014 2014 2014 2012 Public Works Activities: Channelization/Striping: Curb Cut/Access/Sidewalk: Fire Loop Hydrant: Flood Control Zone: Hauling/Oversize Load: Land Altering: Landscape Irrigation: Sanitary Side Sewer: Sewer Main Extension: Storm Drainage: Street Use: Water Main Extension: Water Meter: Volumes: Cut: 0 Fill: 0 Number: 0 No Permit Center Authorized Signature: Date: 4U/ I hearby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this development permit and agree to the conditions attached to this permit. Date: Cit/24/00 This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: The total number of fire extinguishers required for an ordinary hazard occupancy with Class A fire hazards is calculated at one extinguisher for each 1,500 sq. ft. of area. The extinguisher(s) should be of the "All Purpose" (3A, 40B:C) dry chemical type. Travel distance to any fire extinguisher must be 75' or less. (IFC 906.3) (NFPA 10, 5.4) 2: Maintain fire extinguisher coverage throughout. 6: Fire protection systems shall be maintained in accordance with the original installation standards for that system. Required systems shall be extended, altered or augmented as necessary to maintain and continue protection whenever the building is altered, remodeled or added to. Alterations to fire protection systems shall be done in accordance with applicable standards. (IFC 901.4) 4: Sprinklers shall be installed under fixed obstructions over 4 feet (1.2 m) wide. (NFPA 13-8.6.5.3.3) 3: All new sprinkler systems and all modifications to existing sprinkler systems shall have fire department review and approval of drawings prior to installation or modification. New sprinkler systems and all modifications to sprinkler systems involving more than 50 heads shall have the written approval of Factory Mutual or any fire protection engineer licensed by the State of Washington and approved by the Fire Marshal prior to submittal to the Tukwila Fire Prevention Bureau. No sprinkler work shall commence without approved drawings. (City Ordinance No. 2436). 8: Maintain fire alarm system audible/visual notification. Addition/relocation of walls or partitions may require relocation and/or addition of audible/visual notification devices. (City Ordinance #2437) 7: All new fire alarm systems or modifications to existing systems shall have the written approval of The Tukwila Fire Prevention Bureau. No work shall commence until a fire department permit has been obtained. (City Ordinance #2437) (IFC 901.2) 5: Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (City Ordinances #2436 and #2437) 9: Any overlooked hazardous condition and/or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. 10: These plans were reviewed by Inspector 511. If you have any questions, please call Tukwila Fire Prevention Bureau at (206)575-4407. 11: ***BUILDING PERMIT CONDITIONS*** 12: Work shall be installed in accordance with the approved construction documents, and any changes made during construction that are not in accordance with the approved construction documents shall be resubmitted for approval. 13: All permits, inspection record card and approved construction documents shall be kept at the site of work and shall be open to inspection by the Building Inspector until final inspection approval is granted. 14: When special inspection is required, either the owner or the registered design professional in responsible charge, shall employ a special inspection agency and notify the Building Official of the appointment prior to the first building inspection. The special inspector shall furnish inspection reports to the Building Official in a timely manner. 15: A final report documenting required special inspections and correction of any discrepancies noted in the inspections shall be submitted to the Building Official. The final inspection report shall be prepared by the approved special inspection agency and shall be submitted to the Building Official prior to and as a condition of final inspection approval. 16: All construction shall be done in conformance with the Washington State Building Code and the Washington State Energy Code. 17: Notify the City of Tukwila Building Division prior to placing any concrete. This procedure is in addition to any requirements for special inspection. 18: All rack storage requires a separate permit issued through the City of Tukwila Permit Center. Rack storage over 8 -feet in height shall be anchored or braced to prevent overturning or displacement during seismic events. The design and calculations for the anchorage or bracing shall be prepared by a registered professional engineer licensed in the State of Washington. Periodic special inspection is required during anchorage of storage racks 8 feet or greater in height. 19: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of this requirement. 20: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206-431-3670). 21: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center. 22: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 23: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431-3670). 24: Masonry construction shall be special inspected. PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 1700 BUILDING FINAL** 1400 FIRE FINAL 0409 FRAMING 0502 LATH & GYPSUM 4046 SI-EPDXY/EXP CONC 0601 WALL INSULATION 0601 WALL INSULATION 0413 WALL SHEATHING/SHEAR Parcel No: Address: City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-438-9350 Web site: http://www.TukwilaWA.gov DEVELOPMENT PERMIT 3623049097 Permit Number: D16-0110 17750 W VALLEY HWY Project Name: HARTUNG GLASS Issue Date: 6/20/2016 Permit Expires On: 12/17/2016 Owner: Name: Address: Contact Person: Name: SCIOLA FAMILY PROPERTIES LL 17830 W VALLEY HWY, TUKWILA, WA, 98188 TORJAN RONHOVDE Address: 14900 INTERURBAN AVE S , TUKWILA, WA, 98168 Contractor: Name: GATEWAY CONSTRUCTION SVS Address: 5602 2ND AVE S , SEATTLE, WA, 98108-2409 License No: GATEWCS992C3 Lender: Name: Address: Phone: (206) 859-5500 Phone: (206) 621-9111 Expiration Date: DESCRIPTION OF WORK: PROVIDE A 460 SF BLOWER ROOM WITHIN AN EXISTING GLASS MANUFACTURING FACILITY. Project Valuation: $20,000.00 Type of Fire Protection: Sprinklers: YES Fire Alarm: YES Type of Construction: VB Electrical Service Provided by: TUKWILA Fees Collected: $824.42 Occupancy per IBC: F-1 Water District: RENTON Sewer District: RENTON Current Codes adopted by the City of Tukwila: International Building Code Edition: International Residential Code Edition: International Mechanical Code Edition: Uniform Plumbing Code Edition: International Fuel Gas Code: 2012 2012 2012 2012 2012 National Electrical Code: WA Cities Electrical Code: WAC 296-46B: WA State Energy Code: 2014 2014 2014 2012 Public Works Activities: Channelization/Striping: Curb Cut/Access/Sidewalk: Fire Loop Hydrant: Flood Control Zone: Hauling/Oversize Load: Land Altering: Landscape Irrigation: Sanitary Side Sewer: Sewer Main Extension: Storm Drainage: Street Use: Water Main Extension: Water Meter: Volumes: Cut: 0 Fill: 0 Number: 0 Permit Center Authorized Signature: Date: Y I hearby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this development permit and agree to the conditions attached to this permit. Signature:II Date: Print Name: 4 {�(,� This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: The total number of fire extinguishers required for an ordinary hazard occupancy with Class A fire hazards is calculated at one extinguisher for each 1,500 sq. ft. of area. The extinguisher(s) should be of the "All Purpose" (3A, 40B:C) dry chemical type. Travel distance to any fire extinguisher must be 75' or less. (IFC 906.3) (NFPA 10, 5.4) 2: Maintain fire extinguisher coverage throughout. 6: Fire protection systems shall be maintained in accordance with the original installation standards for that system. Required systems shall be extended, altered or augmented as necessary to maintain and continue protection whenever the building is altered, remodeled or added to. Alterations to fire protection systems shall be done in accordance with applicable standards. (IFC 901.4) 4: Sprinklers shall be installed under fixed obstructions over 4 feet (1.2 m) wide. (NFPA 13-8.6.5.3.3) 3: All new sprinkler systems and all modifications to existing sprinkler systems shall have fire department review and approval of drawings prior to installation or modification. New sprinkler systems and all modifications to sprinkler systems involving more than 50 heads shall have the written approval of Factory Mutual or any fire protection engineer licensed by the State of Washington and approved by the Fire Marshal prior to submittal to the Tukwila Fire Prevention Bureau. No sprinkler work shall commence without approved drawings. (City Ordinance No. 2436). 8: Maintain fire alarm system audible/visual notification. Addition/relocation of walls or partitions may require relocation and/or addition of audible/visual notification devices. (City Ordinance #2437) 7: All new fire alarm systems or modifications to existing systems shall have the written approval of The Tukwila Fire Prevention Bureau. No work shall commence until a fire department permit has been obtained. (City Ordinance #2437) (IFC 901.2) 5: Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (City Ordinances #2436 and #2437) 9: Any overlooked hazardous condition and/or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. 10: These plans were reviewed by Inspector 511. If you have any questions, please call Tukwila Fire Prevention Bureau at (206)575-4407. 11: ***BUILDING PERMIT CONDITIONS*** 12: Work shall be installed in accordance with the approved construction documents, and any changes made during construction that are not in accordance with the approved construction documents shall be resubmitted for approval. 13: All permits, inspection record card and approved construction documents shall be kept at the site of work and shall be open to inspection by the Building Inspector until final inspection approval is granted. 14: When special inspection is required, either the owner or the registered design professional in responsible charge, shall employ a special inspection agency and notify the Building Official of the appointment prior to the first building inspection. The special inspector shall furnish inspection reports to the Building Official in a timely manner. 15: A final report documenting required special inspections and correction of any discrepancies noted in the inspections shall be submitted to the Building Official. The final inspection report shall be prepared by the approved special inspection agency and shall be submitted to the Building Official prior to and as a condition of final inspection approval. 16: All construction shall be done in conformance with the Washington State Building Code and the Washington State Energy Code. 17: Notify the City of Tukwila Building Division prior to placing any concrete. This procedure is in addition to any requirements for special inspection. 18: Masonry construction shall be special inspected. 19: All rack storage requires a separate permit issued through the City of Tukwila Permit Center. Rack storage over 8 -feet in height shall be anchored or braced to prevent overturning or displacement during seismic events. The design and calculations for the anchorage or bracing shall be prepared by a registered professional engineer licensed in the State of Washington. Periodic special inspection is required during anchorage of storage racks 8 feet or greater in height. 20: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of this requirement. 21: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206-431-3670). 22: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center. 23: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 24: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431-3670). PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 1700 BUILDING FINAL** 1400 FIRE FINAL 0409 FRAMING 4046 SI-EPDXY/EXP CONC 4022 SI -MASONRY CITY OF TUKH I Community Development Department Public Works Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.TukwilaWA.gov fi Building Pert... No. /(o - o%/ U Project No. Date Application Accepted: Date Application Expires: (For office use only) CONSTRUCTION PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **Please Print** SITE LOCATION Site Address: 17750 West Valley Hwy Tenant Name: Hartung Glass PROPERTY OWNER . Name: Torjan Ronhovde Name: Sciola Family Properties City: Tukwila State: WA Zip: 98188 Address: 17830 W Valley Hwy Email: torjan@ronhovdearchitects.com City: Tukwila State: WA Zip: 98188 CONTACT PERSON — person receiving all project communication Name: Torjan Ronhovde Address: 14900 Interurban Ave S City: Tukwila State: WA Zip: 98188 Phone: (206) 859-5500 Fax: (206) 859-5501 Email: torjan@ronhovdearchitects.com GENERAL CONTRACTOR INFORMATION Company Name: Architect Name: Torjan Ronhovde Address: 14900 Interurban Ave S City: Tukwila State: WA Zip: 98188 Address: Email: torjan@ronhovdearchitects.com City: State: Zip: Phone: Fax: Phone: Fax: Contr Reg No.: Email: Exp Date: Tukwila Business License No.: H:'Applications\Forms-Applications On Line\201 I Applications\Permit Application Revised - 8-9-11.does Revised: August 2011 bh King Co Assessor's Tax No.: 362304-9097 Suite Number: Floor: 1ST New Tenant: ❑ Yes ..No ARCHITECT OF RECORD Company Name: Ronhovde Architects Architect Name: Torjan Ronhovde Address: 14900 Interurban Ave S City: Tukwila State: WA Zip: 98188 Phone: (206) 859-5500 Fax: (206) 859-5501 Email: torjan@ronhovdearchitects.com ENGINEER OF RECORD Name: Address: Company Name: Engineer Name: Address: City: State: Zip: Phone: Fax: Email: LENDER/BOND ISSUED (required for projects $5,000 or greater per RCW 19.27.095) Name: Address: City: State: Zip: Page 1 of 4 BUILDING PERMIT INFORMATIO: 106-431-3670 Valuation of Project (contractor's bid price): $ 20,000 Existing Building Valuation: $ 5,173,000 Describe the scope of work (please provide detailed information): PROVIDE A 460 S.F. BLOWER ROOM WITHIN AN EXISTING GLASS MANUFACTURING FACILITY. Will there be new rack storage? ❑ Yes O.. No If yes, a separate permit and plan submittal will be required. Provide All Building Areas in Square Footage Below PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: 105 Compact: Handicap: 3 Will there be a change in use? El Yes 0 No If "yes", explain: FIRE PROTECTION/HAZARDOUS MATERIALS: Sprinklers Z Automatic Fire Alarm ❑ None ❑ Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes J No If "yes', attach list of materials and storage locations on a separate 8-1/2" x 11" paper including quantities and Material Safety Data Sheets. SEPTIC SYSTEM 0 On-site Septic System — For on-site septic system, provide 2 copies of a current septic design approved by King County Health Department. H:\Applications\Forms-Applications On Line \201 I Applications\permit Application Revised - 8.9.11.docx Revised: August 2011 bh Page 2 of 4 Existing Interior Remodel Addition to Existing Structure New Type of Construction per IBC Type of Occupancy per IBC 1st Floor 54,360 460 0 0 3b F-2 2nd Floor 3rd Floor Floors thru Basement Accessory Structure* Attached Garage Detached Garage Attached Carport Detached Carport Covered Deck Uncovered Deck PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: 105 Compact: Handicap: 3 Will there be a change in use? El Yes 0 No If "yes", explain: FIRE PROTECTION/HAZARDOUS MATERIALS: Sprinklers Z Automatic Fire Alarm ❑ None ❑ Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes J No If "yes', attach list of materials and storage locations on a separate 8-1/2" x 11" paper including quantities and Material Safety Data Sheets. SEPTIC SYSTEM 0 On-site Septic System — For on-site septic system, provide 2 copies of a current septic design approved by King County Health Department. H:\Applications\Forms-Applications On Line \201 I Applications\permit Application Revised - 8.9.11.docx Revised: August 2011 bh Page 2 of 4 PUI3LIC WORKS PERMIT INFOT kTION — 206-433-0179 Scope of Work (please provide detailed information): Call before you Dig: 811 Please refer to Public Works Bulletin #1 for fees and estimate sheet. Water District ❑ ...Tukwila ❑ ...Water District #125 ❑ ...Water Availability Provided Sewer District ❑ ...Tukwila ❑ ...Sewer Use Certificate El .. Highline ❑... Vail ey View ❑ .. Renton ❑ ... Sewer Availability Provided ❑ .. Renton ❑ .. Seattle Septic System: ❑ On-site Septic System — For on-site septic system, provide 2 copies of a current septic design approved by King County Health Department. Submitted with Application (mark boxes which apply): ❑ ...Civil Plans (Maximum Paper Size — 22" x 34") El ...Technical Information Report (Storm Drainage) 0 ...Bond El .. Insurance 0 .. Easement(s) Proposed Activities (mark boxes that apply): ❑ ...Right-of-way Use - Nonprofit for less than 72 hours ❑ ...Right-of-way Use - No Disturbance El ...Construction/Excavation/Fill - Right-of-way ❑ Non Right-of-way ❑ ...Total Cut El ...Total Fill cubic yards cubic yards El ...Sanitary Side Sewer ❑ ...Cap or Remove Utilities El ...Frontage Improvements El ...Traffic Control El ...Backflow Prevention - Fire Protection Irrigation Domestic Water ❑ .. Geotechnical Report ❑ .. Maintenance Agreement(s) ❑ ...Traffic Impact Analysis ❑ ...Hold Harmless — (SAO) ❑ ...Hold Harmless — (ROW) 0 .. Right-of-way Use - Profit for less than 72 hours ❑ .. Right-of-way Use — Potential Disturbance El .. Work in Flood Zone El .. Storm Drainage El .. Abandon Septic Tank E l .. Curb Cut ❑ .. Pavement Cut ❑ .. Looped Fire Line ❑ ...Permanent Water Meter Size... El ...Temporary Water Meter Size .. ❑ ...Water Only Meter Size ❑ ...Sewer Main Extension Public El ...Water Main Extension Public .51 WO# WO# WO # Private ❑ Private El El .. Grease Interceptor ❑ .. Channelization El .. Trench Excavation ❑ .. Utility Undergrounding El ...Deduct Water Meter Size FINANCE INFORMATION Fire Line Size at Property Line El ...Water ❑ ...Sewer ❑ ...Sewage Treatment Monthly Service Billing to: Name: Number of Public Fire Hydrant(s) Day Telephone: Mailing Address: City State Zip Water Meter Refund/Billing: Name: Mailing Address: Day Telephone: City State Zip H:\Applications\Forms-Applications On Line \2011 Applications\Permit Application Revised - 8-9-11.docx Revised: August 2011 bh Page 3 of 4 [RMIT APPLICATION NOTES — Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE AWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILD] Signature. RAU GENT: Print Name: Torjan Ronhovde Mailing Address: 14900 Interurban Ave S H:Wpplications\Forms-Applications On Line \2011 Applications\permit Application Revised - 8-9-11.docx Revised: August 2011 bh Date: 04/27/2016 Day Telephone: (206) 859-0550 Tukwila WA 98188 City State Zip Page 4 of 4 Cash Register Receipt City of Tukwila Receipt Number DESCRIPTIONS PermitTRAK I ACCOUNT I QUANTITY PAID $66.50 D16-0110 Address: 17750 W VALLEY HWY Apn: 3623049097 $66.50 DEVELOPMENT $66.50 ADDITIONAL PLAN REVIEW TOTAL FEES PAID BY RECEIPT: R8822 R000.345.830.00.00 1.00 $66.50 $66.50 Date Paid: Friday, June 24, 2016 Paid By: HARTUNG GLASS Pay Method: CREDIT CARD 071883 Printed: Friday, June 24, 2016 12:04 PM 1 of 1 r1�SYSTEMS Cash Register Receipt City of Tukwila Receipt Number' DESCRIPTIONS ACCOUNT I QUANTITY PermitTRAK PAID $510.92 D16-0110 Address: 17750 W VALLEY HWY Apn: 3623049097 $510.92 DEVELOPMENT $486.80 PERMIT FEE R000.322.100.00.00 0.00 $482.30 WASHINGTON STATE SURCHARGE 8640.237.114 0.00 $4.50 TECHNOLOGY FEE $24.12 TECHNOLOGY FEE TOTAL FEES PAID BY RECEIPT: R8775 R000.322.900.04.00 0.00 $24.12 $510.92 Date Paid: Monday, June 20, 2016 Paid By: TIMOTHY KRONA Pay Method: CREDIT CARD 07599D Printed: Monday, June 20, 2016 8:59 AM 1 of 1 rrSYSTEMS INSPECTION NO. INSPECTION RECORD Retain a copy with permit 116-a//0 PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project PA ! tiiMJ6 o1 SS Type of Inspection: / JA LL Z ui ..4 -rho ,✓ Address: ) 770 GSI VALt6/ /41,..)i Date Called: Special Instructions: M^. Am 19 0t t �Q(" �!l �� Date Wanted: Date j !! s a.m. p.m. Requester: Phone No: Approved per applicable codes. a Corrections required prior to approval. COMMENTS: P (4 Inspector: Date:/' 2 (Z n REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit NSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Df4--olf0 Pro'ect: G fra Type of Inspection:c, FirettGa ij A ress� ['715'0 �, lief (kr wti Date Called: Special Instructions: s/f h`V 1� h / CNVA t t>e_, k ( S 1 kk.. j l�G� C `S Date gante2c.I.:, �� a.m. P.m. Requester: Phone No: Approved per applicable codes. El Corrections required prior to approval. COMMENTS: rO(A /Lie r(Q rvkt rs 01A. s re Inspector: Date 6 ` Z) ) REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. INSPECTION NUMBER INSPECTION RECORD Retain a copy with permit If PERMIT NUMBERS CITY OF TUKWILA FIRE DEPARTMENT 206-575-4407 Project: ,/� /7 t t.,t+N4 / /./.4_5'S" Type of Inspection: 5 (--)r tiJCA-C-- Address: 17 73-7) Suite #: , toU 4Contact Person: Special Instructions: Occupancy Type: Phone No.: Approved per applicable codes. Corrections required prior to approval. COMMENTS: (a) ( vtJw 1 -- C� Needs Shift Inspection: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: Inspector: (A! ( Date: S — f — U -6 Hrs.: $100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila -Finance Department. Call to schedule a reinspection. Billing Address Attn: Company Name: Address: City: State: Zip: Word/Inspection Record Form.Doc 3/14/14 T.F.D. Form F.P. 113 1/2/2018 City of Tukwila Department of Community Development TORJAN RONHOVDE 14900 INTERURBAN AVE S TUKWILA, WA 98168 RE: Permit No. D16-0110 HARTUNG GLASS 17750 W VALLEY HWY Dear Permit Holder: Allan Ekberg, Mayor Jack Pace, Director In reviewing our current records, the above noted permit has not received a final inspection by the City of Tukwila Building Division. Per the International Building Code, International Mechanical Code, Uniform Plumbing Code and/or the National Electric Code, every permit issued by the Building Division under the provisions of these codes shall expire by limitation and become null and void if the building or work authorized by such permit has not begun within 180 days from the issuance date of such permit, or if the building or work authorized by such permit is suspended or abandoned at any time after the work has begun for a period of 180 days. Your permit will expire on 2/6/2018. Based on the above, you are hereby advised to: 1) Call the City of Tukwila Inspection Request Line at 206-438-9350 to schedule for the next or fmal inspection. Each inspection creates a new 180 day period, provided the inspection shows progress. -or- 2) Submit a written request for permit extension to the Permit Center at least seven(7) days before it is due to expire. Address your extension request to the Building Official and state your reason(s) for the need to extend your permit. The Building Code does allow the Building Official to approve one extension of up to 180 days. If it is determined that your extension request is granted, you will be notified by mail. In the event you do not call for an inspection and/or receive an extension prior to 2/6/2018, your permit will become null and void and any further work on the project will require a new permit and associated fees. Thank you for your cooperation in this matter. Sincerely, Bill Rambo Permit Technician File No: D16-0110 6300 Southcenter Boulevard Suite #100 • Tukwila, Washington 98188 • Phone 206-431-3670 • Fax 206-431-3665 City of Tukwila Allan Ekberg, Mayor Department of Community Development - Jack Pace, Director August 8, 2017 Jeff Edvalds Hartung Glass 17750 W Valley Hwy Tukwila, WA 98188 RE: Request for Extension #1 Permit Number D16-0110 Dear Mr. Edvalds, This letter is in response to your written request for an extension to Permit D16-0110. The Building Official, Jerry Hight, has reviewed your letter and considered your request to extend the above referenced permit. It has been determined that the City of Tukwila Building Division will be granting an extension to the permit through February 06, 2018. If you should have any questions, please contact our office at (206) 431-3670. Sincerely, Rachelle Ripl y Permit Technician File: Permit No. D16-0110 Tukwila City Hall • 6200 Southcenter Boulevard • Tukwila, WA 98188 • 206-433-1800 • Website: TukwilaWA.gov Rachelle Ripley From: Sent: To: Cc: Subject: Importance: Hello Bill, Jeff Edvalds <jedvalds@hartung-glass.com> Friday, July 28, 2017 4:06 PM Bill Rambo Permits Request for permit extension of D16-0110 High I wanted to send you a letter requesting an extension for permit D16-0110. The reason for the request is because we are in the process of taking bids for the relocation of our fire panel this month with the expectation of having it moved by the end of August which would go past the expiration date of August 6th 2017. This is due to a recent fire inspection where the fire department is asking us to move the fire panels current location to one more accessible to the fire department. If you have any questions or I need to do more to fulfill this request, please let me know? Thank you for your time. Thanks Jeff Edvalds Jeff Edvalds Training Coordinator Hartung Glass Industries iedvalds@hartung-glass.com Building partners through glass. KARTVNG GLASS ommsrAres Request for EL e.nsion # Current Expiration Date: �� Extension Request: Approved for / t(% days Denied (provide explanation) 1 /4/Signature/Initials 7/3/2017 City of Tukwila Department of Community Development TORJAN RONHOVDE 14900 INTERURBAN AVE S TUKWILA, WA 98168 RE: Permit No. D16-0110 HARTUNG GLASS 17750 W VALLEY HWY Dear Permit Holder: Allan Ekberg, Mayor Jack Pace, Director In reviewing our current records, the above noted permit has not received a final inspection by the City of Tukwila Building Division. Per the International Building Code, International Mechanical Code, Uniform Plumbing Code and/or the National Electric Code, every permit issued by the Building Division under the provisions of these codes shall expire by limitation and become null and void if the building or work authorized by such permit has not begun within 180 days from the issuance date of such permit, or if the building or work authorized by such permit is suspended or abandoned at any time after the work has begun for a period of 180 days. Your permit will expire on 8/6/2017. Based on the above, you are hereby advised to: 1) Call the City of Tukwila Inspection Request Line at 206-438-9350 to schedule for the next or final inspection. Each inspection creates a new 180 day period, provided the inspection shows progress. -or- 2) Submit a written request for permit extension to the Permit Center at least seven(7) days before it is due to expire. Address your extension request to the Building Official and state your reason(s) for the need to extend your permit. The Building Code does allow the Building Official to approve one extension of up to 180 days. If it is determined that your extension request is granted, you will be notified by mail. In the event you do not call for an inspection and/or receive an extension prior to 8/6/2017, your permit will become null and void and any further work on the project will require a new permit and associated fees. Thank you for your cooperation in this matter. Sincerely, Bill Rambo Permit Technician File No: D16-0110 6300 Southcenter Boulevard Suite #100 • Tukwila, Washington 98188 • Phone 206-431-3670 • Fax 206-431-3665 1/3/2017 City of Tukwila Department of Community Development TORJAN RONHOVDE 14900 INTERURBAN AVE S TUKWILA, WA 98168 RE: Permit No. D16-0110 HARTUNG GLASS 17750 W VALLEY HWY Dear Permit Holder: Allan Ekberg, Mayor Jack Pace, Director In reviewing our current records, the above noted permit has not received a final inspection by the City of Tukwila Building Division. Per the International Building Code, International Mechanical Code, Uniform Plumbing •Code and/or the National Electric Code, every permit issued by the Building Division under the provisions of these codes shall expire by limitation and become null and void if the building or work authorized by such permit has not begun within 180 days from the issuance date of such permit, or if the building or work authorized by such permit is suspended or abandoned at any time after the work has begun for a period of 180 days. Your permit will expire on 2/6/2017. Based on the above, you are hereby advised to: 1) Call the City of Tukwila Inspection Request Line at 206-438-9350 to schedule for the next or final inspection. Each inspection creates a new 180 day period, provided the inspection shows progress. -or- 2) Submit a written request for permit extension to the Permit Center at least seven(7) days before it is due to expire. Address your extension request to the Building Official and state your reason(s) for the need to extend your permit. The Building Code does allow the Building Official to approve one extension of up to 180 days. If it is determined that your extension request is granted, you will be notified by mail. In the event you do not call for an inspection and/or receive an extension prior to 2/6/2017, your permit will become null and void and any further work on the project will require a new permit and associated fees. Thank you for your cooperation in this matter. Sincerely, Bill Rambo Permit Technician File No: D16-0110 6300 Southcenter Boulevard Suite #100 • Tukwila, Washington 98188 • Phone 206-431-3670 • Fax 206-431-3665 T H E RONHOVDE ARCHITECTS L L C June 1,2016 Allen Johannessen Plans Examiner City of Tukwila Department of Community Development 6300 Southcenter Blvd. #100 Tukwila, WA 98188 RECEIVED CITY OF TUKWILA JUN 0.1 2016 PERMIT CENTER Re: D16-0110, Hartung Glass Dear Mr. Johannessen, Attached are 4 copies of the revised plans. The following comments relate to the numbers in your plan review letter dated May 6, 2016. Background: The owners have decided to"hangthe construction of the blower room from CMU to Steel Studs. The steel stud wall framing will extend from floor to roof deck with a deflection track. This deletes the room ceiling structure. General The plans are all wet signed as requested. Building 1) No longer applies. CMU has been deleted from project. 2) The mechanical system including louvers, make-up and relief air are a deferred submittal to be made by the mechanical sub -contractor designer. The following is a system statement provided by the owners: The blower room is a sealed room that has two openings for air intake. These openings are approx. 100 SF. The openings are NOT used at the same time. The majority of the time outside air will be drawn in through the roof top louver. In the cooler months the outside air louver is closed and tempered air is drawn in from the interior of the building through the wall louver. The air that is pulled through the blowers is released out into the plant floor upon exiting tempering furnace. That air is exhausted to the exterior by fans. We are enclosing 4 complete sets of all revised drawings, CS, A1.1 and A2.1. Please let me know if you need anything additional. rely, Tor -Jan Ronhovde, Architect The Ronhovde Architects, LLC 6625 South 190th Street, Suite B-105, Kent, WA 98032 PH. (425) 656-0500 FAX. (425) 656-0501 D1(—o(iO May 06, 2016 City of Tukwila Department of Community Development TORJAN RONHOVDE 14900 INTERURBAN AVE S TUKWILA, WA 98168 RE: Correction Letter # 1 DEVELOPMENT Permit Application Number D16-0110 HARTUNG GLASS - 17750 W VALLEY HWY Dear TORJAN RONHOVDE, Allan Ekberg, Mayor Jack Pace, Director This letter is to inform you of corrections that must be addressed before your development permit can be approved. All correction requests from each department must be addressed at the same time and reflected on your drawings. I have enclosed comments from the following departments: BUILDING DEPARTMENT: Allen Johannessen at 206-433-7163 if you have questions regarding these comments. • (GENERAL NOTE) PLAN SUBMITTALS: (Min. size 11x17 to maximum size of 24x36; all sheets shall be the same size. New revised plan sheets shall be the same size sheets as those previously submitted.) (If applicable) "STAMP AND SIGNATURES" "Every page of a plan set must contain the seal/stamp, signature of the licensee(s) who prepared or who had direct supervision over the preparation of the work, and date of signature. Specifications that are prepared by or under the direct supervision of a licensee shall contain the seal/stamp, signature of the licensee and the date of signature. If the "specifications" prepared by a licensee are a portion of a bound specification document that contains specifications other than that of an engineering or land surveying nature, the licensee need only seal/stamp that portion or portions of the documents for which the licensee is responsible." It shall not be required to have each page of "specifications" (calculations) to be stamped and signed; Front page only will be sufficient. (WAC 196-23-010 & 196-23-020) (BUILDING REVIEW NOTES) 1. Masonry shall be special inspected. Provide special inspections matrix table for masonry, steel and concrete. Include specifications for the concrete slab construction with details. Specify how the slab ties into the existing slab. Provide engineers calculations. 2. Indicate if the blower is taking air from the outside and show the details for any new openings. Also indicate the method for supply and return air where it shall not affect the conditioned space. Please include some additional information for the purpose of the blower and its function. Please address the comments above in an itemized format with applicable revised plans, specifications, and/or other documentation. The City requires that two (2) sets of revised plan pages, specifications and/or other documentation be resubmitted with the appropriate revision block. In order to better expedite your resubmittal, a 'Revision Submittal Sheet' must accompany every resubmittal. I have enclosed one for your convenience. Corrections/revisions must be made in person and will not be accepted through the mail or by a messenger service. 6300 Southcenter Boulevard Suite #100 • Tukwila Washington 98188 • Phone 206-431-3670 • Fax 206-431-3665 If you have any questions, I can be reached at 206-431-3655. Sincerely, Bill Rambo Permit Technician File No. D16-0110 6300 Southcenter Boulevard Suite #100 • Tukwila Washington 98188 • Phone 206-431-3670 • Fax 206-431-3665 PERMIT COORD COPY PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: D16-0110 PROJECT NAME: HARTUNG GLASS SITE ADDRESS: 17750 W VALLEY HWY DATE: 06/13/16 Original Plan Submittal Revision # before Permit Issued Response to Correction Letter # X Revision # 1 after Permit Issued DEPARTMENTS: A -S Auk Building Division Wo ks AJ/4 ublic Fire Prevention Structural • Planning Division to --)-t ❑ Permit Coordinator 1111 PRELIMINARY REVIEW: Not Applicable ❑ (no approval/review required) DATE: 06/14/16 Structural Review Required REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: Approved Corrections Required DUE DATE: 07/12/16 Approved with Conditions re Denied (corrections entered in Reviews) I (ie: Zoning Issues) Notati( Y Ove �1Gt t S ` rui4n),, Wet awl REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: 12/18/2013 PERMIT COORD COPY PLAN REVIEW/ROUTING SLIP 11. PERMIT NUMBER: D16-0110 DATE: 06/06/16 PROJECT NAME: HARTUNG GLASS SITE ADDRESS: 17750 W VALLEY HWY Original Plan Submittal Revision # before Permit Issued X Response to Correction Letter # 1 Revision # after Permit Issued DEPARTMENTS: A kwc (01-16 Building Division 1114 Public Works n Fire Prevention Structural Planning Division ❑ Permit Coordinator n n PRELIMINARY REVIEW: Not Applicable (no approval/review required) DATE: 06/07/16 Structural Review Required REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: Approved DUE DATE: 07/05/16 n Approved with Conditions IV Corrections Required Denied (corrections entered in Reviews) Notation: (ie: Zoning Issues) REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire 0 Ping 0 PW ❑ Staff Initials: 12/18/2013 PERMIT COORD COPY PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: D16-0110 DATE: 04/27/16 PROJECT NAME: HARTUNG GLASS SITE ADDRESS: 17750 WEST VALLEY HWY X Original Plan Submittal Revision # before Permit Issued Response to Correction Letter # Revision # after Permit Issued DEPARTMENTS: Building Division Public Wor s A -vi S s-12 \/ L /1/4)/A___ Fire Prevention i Planning Division it Structural ❑ Permit Coordinator n PRELINIINARY REVIEW: Not Applicable n (no approval/review required) DATE: 05/03/16 Structural Review Required REVIEWER'S INITIALS: DATE: n APPROVALS OR CORRECTIONS: DUE DATE: 05/31/16 Approved Corrections Required ❑ Approved with Conditions ❑ Denied (corrections entered in Reviews) — (ie: Zoning Issues) Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg Fire ❑ Ping ❑ PW ❑ Staff Initials: 12/18/2013 PROJECT NAME: 41PERMIT NO: b.,Ip -0 t 0 SITE ADDRESS: �1� LVaccSY Hw1 u �e ORIGINAL ISSUE DATE: RENIS][ N LOG REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF INITIALS I (o—t3-1 Summary of Revision: (14,t4c, ChA(1 (-vat , f ct (.coo / ve i ,v - LA..: 4za. sir. . 41& v✓ved wet 0 (I 6 ' l t - — 741)3*e(1-4-' Received by:, ORM -, REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF INITIALS 1 Summary of Revision: Received by: please print) REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF INITIALS 1 Summary of Revision: Received by: (please print) REVISION NO. IATE RECEIVED STAFF INITIALS ISSUED DATE STAFF INITIALS 1 Summary of Revision: Received by: (please print) REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF INITIALS Summary of Revision: Received by: (please print) REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF INITIALS Summary of Revision: Received by: (please nrint) Date: 6-13-16 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Web site: http://www.TukwilaWA.gov REVISION SUBMITTAL Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fax, etc. Plan Check/Permit Number: D16-0110 ❑ Response to Incomplete Letter # Response to Correction Letter # Revision # I after Permit is Issued ❑ Revision requested by a City Building Inspector or Plans Examiner ❑ Deferred Submittal # f7 Project Name: HARTUNG GLASS Project Address: 17750 WEST VALLEY ROAD Contact Person: TORJAN RONHOVDE Phone Number: 206-559-5500 Summary of Revision: DELETE CMU INFILL WALL AND REPLACE WITH METAL STUD FRAMED WALL. CMU IS DELETED FROM THIS PROJECT. RECEWED CITY OF TUKWILA JUN 13 20 PERMIT CENTER Sheet Number(s): "Cloud" or highlight all areas of revision including date of revisipn Received at the City of Tukwila Permit Center by: Entered in TRAKiT on tQ W:\Permit Center \Templates\Forms\Revision Submittal Formdoc Revised: August 2015 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Web site: http://www.TukwilaWA.gov REVISION SUBMITTAL Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fax, etc. Date: 6i /-40, Plan Check/Permit Number: 016 - 01/0 ❑ Response to Incomplete Letter # Response to Correction Letter # ❑ Revision # after Permit is Issued ❑ Revision requested by a City Building Inspector or Plans Examiner ❑ Deferred Submittal # Project Name: iyie# n 4 1,44.1 Project Address: /" a ' . / //r 3id4 Contact Person: i / p. O)11 6V,, Phone Number: Zi6. 651- ''S'(„tc, Summary of Revision: n rebel l res P it f e f 4. Moto 6 /S/v 14' fay r,<zp0 A AA Isterle.471fer e4 14 RECEIVED CITY OF Thi JUN 0 1 2016 PERMIT CEN Sheet Number(s): ! At IA - r I "Cloud" or highlight all areas of revision including date gf revvis'ion 0a#(4, Received at the City of Tukwila Permit Center by: ❑ Entered in TRAKiT on W:\Permit Center \Templates\Forms\Revision Submittal Form.doc Revised: August 2015 GATEWAY CONSTRUCTION SRW'S INC Home .Espanol Contact Safety & Health Claims & Insurance 0 Washington State Department of Labor & Industries Search L&I Page 1 of 2 A -Z Index help My LF:I Workplace Rights Trades & Licensing GATEWAY CONSTRUCTION SRVCS INC Owner or tradesperson Principals SACCO, RONALD, PRESIDENT NIELSEN, CRISTIAN, VICE PRESIDENT Doing business as GATEWAY CONSTRUCTION SRVCS INC WA UBI No. 602 086 011 5602 2nd Ave. S. SEATTLE, WA 98108 206-621-9111 KING County Business type Corporation Governing persons CHARLES J PORTER CRIS J NIELSEN; License Verify the contractor's active registration / license / certification (depending on trade) and any past violations. Construction Contractor License specialties GENERAL License no. GATEWCS992C3 Effective — expiration 02/26/2001— 03/04/2018 Bond Berkley Insurance Co Bond account no. 0193811 Active. Meets current requirements. $12,000.00 Received by L&I Effective date 08/25/2015 08/19/2015 Expiration date Until Canceled TRAVELERS CAS & SURETY CO Bond account no. 105165492 $12,000.00 Received by L&I Effective date 08/21/2008 08/19/2008 Expiration date Until Canceled Insurance Travelers Indemnity Company Th $1,000,000.00 Policy no. 3US-0q9L(L13-3 https://secure.lni.wa.gov/verify/Detail.aspx?UBI=602086011 &LIC=GATEWCS992C3&SAW= 6/23/2016 (EX) GONG. VIALL-N (EX) WOMEN Aoo 1-03 (EX) MEN =4 15 C-0 X X /-(EX) SCREEN - 1 I I I I rl•TFF1991 11111111 1 1 1 I 1 I 1 I v -(EX) GOL 1 1 V(EX) FLOOR DRAIN 4. 4. (EX) GONG. WIALL-N lj ADD (2) 2x6 HF#2 EACH SIDE OF NEN OPNG. TM. WALL ASSEMBLY: 6" STL STUD (6005125-68) AT 16' O.C. 11111-1 5-1/2' SOUND ATTENUATION INSULATION AND 5/8' TYPE 'X' 64 EA. SIDE. BLOWER ROOM BLOWER BY OTHERS INSTALL ON SPRING VIBRATION ISOLATION MOUNTS WITH MIN. 2" STATIC DEFLECTION /\ INTAKE LOUVER GENTER OPENING BETWEEN ROOF PURLINS AND BLOWER UNIT BELOW!. SEE DEFERRED MEGH. SUBMITTAL 11 STEEL BOX BEAM HEADER DEFLEGTION TRACK, TYP (EX) GONG. SLAB • ZSJ CN WOMEN (EX) GONG. NALL' L.JITO —(E EN 0 X GLASTON FG500 BY OTHERS -----' (4) 4' x 48" SUSPENDED STRPLIGHT, (2) F321-8 LAMP, ( LITHONIA G-2-32 (OR SIMILAR) - 58 WATTS BLOWER BY OTHERS VERIFY LOGATION AND GLEARANGES (EX) ROOF DECK AND COVERING —IF (EX) ROOF PURLINS (EX) ROOF BEAM BLOWER DUCTWORK SEE DEFERRED MECHANICAL SUBMITTAL. SECTION A 5GALE: 1/4' = 1'-0" SAN GUT (ENTIRE DEPTH OF EXISTING SLAB) AROUND THE FOOTPRINT OF BLOWER ROOM TO PROVIDE STRUCTURAL BREAK BETWEEN BLOWER ROOM AND REST OF BUILDING. 36' MIN. GLR Loo< BLOWER NR,1 (EX) ADJACENT TENANT RETAIL SPACES (EX) GONG. DEMISING NALL -N J :- (EX) MAINT B 0 E 00W 24'4' 7/ORKIN AREA (Ex) XL PTI:= -ILtZ,L)" mia ..1 ------- __ = .. BLOWER NR,1 (EX) ADJACENT TENANT RETAIL SPACES (EX) GONG. DEMISING NALL -N J :- (EX) MAINT B 0 E 00W 24'4' 7/ORKIN AREA (Ex) XL PTI:= -ILtZ,L)" mia ..1 ANN 0.4..- I) 7 ,..7.-..r.,7,7-..‘........, ...7....-7,,,,.....:1, .....,,........... --. .'. ",..,..14,..r...1 nOman ,-..... WE 5,3,5.11T17, TII (EX) MAINT (EX) GONG. WALL 9 rn (EX) GOL 0,4E4 GOL (p() MIANUFACTL RING GENERAL NOTES I. DUCT, PIPING, CONDUIT PENETRATIONS OF THE BLOWER ROOM SHOULD BE MADE WITH A SMALL GAP (LESS THAN 1/4") AROUND THE SYSTEM PENETRATION, AND GAULKED AIR TIGHT USING ACOUSTICAL CAULK, BACKER ROD, AND PACKED INSULATION IN METAL SLEEVE. 2. JERVIGE PIPES PENETRATING THE EXISTING CONCRETE DEMISING }ALL SHOULD BE SEALED AIR TIGHT NTH ACOUSTICAL CAULK (I/4' GAP AROUND PIPE). 3. ALL DUCTS EXPOSE!) TO WORKING AREA SHOULD BE CONSTRUCTED OF A MIN. 16 GAGE SHEE1 METAL MD EXTERNALLY WRAPPED WITH 2 LB/SF LAGGING. MATERIAL (50UZSEAL B-20/GFA-3). SEE DEFERRED MECHANICAL SUBMITTAL. DEMO FLAG NOTES ® REMOVE OVERHEAD ROLL -UP DOOR AND FRAME i0 REMOVE MOD STAIRS O REMOVE OFFICE WALLS, CEILING, DOORS, FINISHES, AND ELECTRICAL O REMOVE PORTION OF GHAINLINK SCREENING FENGE 1605 SANGUT EXISTING GONG. SLAB (ENTIRE THICKNESS) AROUND FOOTPRINT OF PROPOSED BLOWER ROOM TO PROVIi TRUG BREAK ;au OWER • ..0,1 AND THE REST OF i,, BUILD' (7) REMOVE PORTION OF ROOF DECK AND COVERING FOR NEW INTAKE LOUVER. VERIFY OPENING SIZE AND LOGATION FLOOR PLAN FLAG NOTES 0 INFILL 10' x 10' OPENING IN EXISTING GONG. WALL WITH NEN FRAMED NALL. SEE SECTION "A" ® 4' x 10' x 10' REMOVABLE MET IIR I . 42 5TG NOISEBARRIER LLG., QUIETMOD H/P-42 REMOVABLE H -JOINER OR EQ, DOOR SCHEDULE . A . Eytert v." te t friS E -9-t r ktradofi; - 1-6-h•rto* y tA) • T H E RONHOVDE ARCHITECTS L L C 14q00 INTERURBAN AVE SOUTH SUITE 138 TUKINILA, WASHINGTON (1816E3 (206) 654-5500 1 FAX (206) 854-5501 ronhoyclearchitects.co REGISTE' ED ARCHIT - A RONI-It DE STATE OF WAS GTON ( 1 ) 31-0' x 11-0' x 1-3/4" INSULATE) HOLLOW METAL, MIN 16 GA STEEL FRAME FULL PERIMETER SOUND SEALS JAMB/FEAD. PEMKO 350_SR NOP 105 MILLED BOTTOM: PEMKO 434_RL OR SURFAGED MOUNTED BOTTOM: PEMKO ADA LEVER HANDLE LOCKABLE HARDNARE FILE COPY Permit Im®. bi (0-0 110 • :WON 5ppkow,i1 is subject to errors and omissions. vr.eicf emstrniion documents does not authorize cScny adopted code or ordinance. Reccipt of akAovc-..; Fiold Copy and conditions is acknowledged: Date: A AAA, fo/z9( 26 i City of Tukwila GENERAL DOOR NOTE& ILDING DIVISION - ALL INTERIOR AND EXTERIOR DOORS NOTED SHALL. HAVE LOCKS PROVIDED II/ HARDWARE THAT 15 READILY OPENABLE FROM THE EGRESS SIDE WITHOUT THE USE OF A KEY OR.SPECIAL KNOWLEDGE PER IBC 1008.1.q - ALL HARDWARE PULLS, ,HANDLES, LOCKS, LATGHES OR OTHER OPERATING DEVICES SHALL NOT REQUIRE TIGHT GRASPING, PINCHING OR TWISTING OF THE MIST TO OPERATE PER IBC 1008.1.8.1 - ALL EXTERIOR DOORS TO BE EQUIPPED WITH THRESHOLDS WITH A MAXIMUM RISE OF 1/2' PER ANSI 4042.4. -ALL DOORS IF NOT SPECIFICALLY NOTED OTHERNISE SHALL BE PROVIDED WITH ADA LEVER HANDLE HARDWARE GOMPLYING WITH ANSI 4042.6. - ALL HARDWARE TO BE MOUNTED WITH OPERABLE PARTS LOCATED BETWEEN 34" AND 48" ABOVE THE FLOOR PER ANSI 4042.6. - SEE SHEET A1.0 FOR LOCATIONS OF DOORS REQUIRED TO BE EQUIPPED MTh EXIT SIGNAGE AND EXIT ILLUMINATION. - DOOR CLOSERS SHALL BE ADJUSTED 50 THAT FROM THE OPEN POSITION OF ci0 DEGREES, TIE TIME REQUIRED TO MOVE THE DOOR TO AN OPEN POSITION OF 12 DEGREES SHALL BE 5 SECONDS MIN. -IN GROUP OGGUPANGY OR GROUP 'A' OR 'E' OCCUPANCY WITH 50 OR MORE OGGUPANT LOAD, PANIC AND FIRE EXIT HARDWARE SHALL BE PROVIDED ON ALL DOORS VI/LOCKS AND LATCHES PER IBC 1008.1.10. - LAZING AT DOORS SHALL HAVE A LENGTH MEASURED IN THE DIRECTION OF EGRESS TRAVEL OF NOT LESS THAN 44 INCHES I-tR IBC.. 1008.1.6. -WHEN A LANDING SERVES AN OCCUPANT LOAD OF 50 OR MORE, DOORS IN ANY POSITION SHALL NOT REDUCE THE LANDING TO LESS THAN ONE-HALF ITS REQUIRED WITH IBC 1008.1.6. LIGHTING ENERGY CALCULATION REVISIONS No changes sholl bn made to the scope of kvork ‘,vithoi1 prior approval of Building Division. i'eviscrie will require a new plan submittal al id may incudo additional pian review fees. PER MEG 2012 EDITION TABLE G40552 (1) INTERIOR LIGHTING SUMMARY - SPACE BY SPACE TOTAL ALLOWED WATTS: 0.q5 WATT x 3qI SF = 311 WATTS -.T0tLNATT5 PROPOSED = 232 (EX) LOADING DOCK SEPArl.A.TE PERMIT REQUiRED FOR: EAloctlanical aEle,etrical El'Plumbing czi,Gas Piping aty of Tukwila DIVISION LOUVER SCHEDULE FEB 06 2018 RECEIVED CITY OF TUKWILA JUN la 2016 PERMIT CENTER 10L0' x 10'-0", ALUM, SCREEN ON INSIDE, MOTORIZED DAMPER, c16.q 5F MIN NET AREA OF THE INTAKE ORIFICE FOR WINTER TIME OPERATING ABT. < +5 DEG G VERIFY SIZE AND LOGATION 81-0" x 121-0", ALUM, SCREEN ON INSIDE, MOTORIZED DAMPER, c16.01 SF MIN NET AREA OF THE INTAKE ORIFICE FOR SUMNER TIME OPERATING ABT. +5 DEG G VERIFY SIZE AND LOCATION. cr. ,r ••••-•••+9 tr:' LAN !. APPR!....!Er.) • chanpes be iTode to these plans without opproval from the Planning Division of DCD 0110 FOR COMPLIANCE APPROVED 11.114 24 2016 . 7/711-71- octutaiicta $UILDING DIVISION 10 8 6 5 4 3 6-10-16 DELETE GMU MU_ 2 06-01-16 AGENCY REVIEW RESPONSES 4 OR CHANGES 04-27-16 PERMIT SUBMITTAL NO. DATE DESCRIPTION REVISIONS SHEET CONTENTS: PLANS, SECTIONS, SCHEDULES JOB NO.: 2016.05.6 DRAWN BY: DGF CHECKED BY: TX DATE: 4-26-16 SHEET NO. A1.1 -ILtZ,L)" 0.4..- I) 7 ,..7.-..r.,7,7-..‘........, ...7....-7,,,,.....:1, .....,,........... --. .'. ",..,..14,..r...1 nOman ,-..... WE 5,3,5.11T17, TII (EX) MAINT (EX) GONG. WALL 9 rn (EX) GOL 0,4E4 GOL (p() MIANUFACTL RING GENERAL NOTES I. DUCT, PIPING, CONDUIT PENETRATIONS OF THE BLOWER ROOM SHOULD BE MADE WITH A SMALL GAP (LESS THAN 1/4") AROUND THE SYSTEM PENETRATION, AND GAULKED AIR TIGHT USING ACOUSTICAL CAULK, BACKER ROD, AND PACKED INSULATION IN METAL SLEEVE. 2. JERVIGE PIPES PENETRATING THE EXISTING CONCRETE DEMISING }ALL SHOULD BE SEALED AIR TIGHT NTH ACOUSTICAL CAULK (I/4' GAP AROUND PIPE). 3. ALL DUCTS EXPOSE!) TO WORKING AREA SHOULD BE CONSTRUCTED OF A MIN. 16 GAGE SHEE1 METAL MD EXTERNALLY WRAPPED WITH 2 LB/SF LAGGING. MATERIAL (50UZSEAL B-20/GFA-3). SEE DEFERRED MECHANICAL SUBMITTAL. DEMO FLAG NOTES ® REMOVE OVERHEAD ROLL -UP DOOR AND FRAME i0 REMOVE MOD STAIRS O REMOVE OFFICE WALLS, CEILING, DOORS, FINISHES, AND ELECTRICAL O REMOVE PORTION OF GHAINLINK SCREENING FENGE 1605 SANGUT EXISTING GONG. SLAB (ENTIRE THICKNESS) AROUND FOOTPRINT OF PROPOSED BLOWER ROOM TO PROVIi TRUG BREAK ;au OWER • ..0,1 AND THE REST OF i,, BUILD' (7) REMOVE PORTION OF ROOF DECK AND COVERING FOR NEW INTAKE LOUVER. VERIFY OPENING SIZE AND LOGATION FLOOR PLAN FLAG NOTES 0 INFILL 10' x 10' OPENING IN EXISTING GONG. WALL WITH NEN FRAMED NALL. SEE SECTION "A" ® 4' x 10' x 10' REMOVABLE MET IIR I . 42 5TG NOISEBARRIER LLG., QUIETMOD H/P-42 REMOVABLE H -JOINER OR EQ, DOOR SCHEDULE . A . Eytert v." te t friS E -9-t r ktradofi; - 1-6-h•rto* y tA) • T H E RONHOVDE ARCHITECTS L L C 14q00 INTERURBAN AVE SOUTH SUITE 138 TUKINILA, WASHINGTON (1816E3 (206) 654-5500 1 FAX (206) 854-5501 ronhoyclearchitects.co REGISTE' ED ARCHIT - A RONI-It DE STATE OF WAS GTON ( 1 ) 31-0' x 11-0' x 1-3/4" INSULATE) HOLLOW METAL, MIN 16 GA STEEL FRAME FULL PERIMETER SOUND SEALS JAMB/FEAD. PEMKO 350_SR NOP 105 MILLED BOTTOM: PEMKO 434_RL OR SURFAGED MOUNTED BOTTOM: PEMKO ADA LEVER HANDLE LOCKABLE HARDNARE FILE COPY Permit Im®. bi (0-0 110 • :WON 5ppkow,i1 is subject to errors and omissions. vr.eicf emstrniion documents does not authorize cScny adopted code or ordinance. Reccipt of akAovc-..; Fiold Copy and conditions is acknowledged: Date: A AAA, fo/z9( 26 i City of Tukwila GENERAL DOOR NOTE& ILDING DIVISION - ALL INTERIOR AND EXTERIOR DOORS NOTED SHALL. HAVE LOCKS PROVIDED II/ HARDWARE THAT 15 READILY OPENABLE FROM THE EGRESS SIDE WITHOUT THE USE OF A KEY OR.SPECIAL KNOWLEDGE PER IBC 1008.1.q - ALL HARDWARE PULLS, ,HANDLES, LOCKS, LATGHES OR OTHER OPERATING DEVICES SHALL NOT REQUIRE TIGHT GRASPING, PINCHING OR TWISTING OF THE MIST TO OPERATE PER IBC 1008.1.8.1 - ALL EXTERIOR DOORS TO BE EQUIPPED WITH THRESHOLDS WITH A MAXIMUM RISE OF 1/2' PER ANSI 4042.4. -ALL DOORS IF NOT SPECIFICALLY NOTED OTHERNISE SHALL BE PROVIDED WITH ADA LEVER HANDLE HARDWARE GOMPLYING WITH ANSI 4042.6. - ALL HARDWARE TO BE MOUNTED WITH OPERABLE PARTS LOCATED BETWEEN 34" AND 48" ABOVE THE FLOOR PER ANSI 4042.6. - SEE SHEET A1.0 FOR LOCATIONS OF DOORS REQUIRED TO BE EQUIPPED MTh EXIT SIGNAGE AND EXIT ILLUMINATION. - DOOR CLOSERS SHALL BE ADJUSTED 50 THAT FROM THE OPEN POSITION OF ci0 DEGREES, TIE TIME REQUIRED TO MOVE THE DOOR TO AN OPEN POSITION OF 12 DEGREES SHALL BE 5 SECONDS MIN. -IN GROUP OGGUPANGY OR GROUP 'A' OR 'E' OCCUPANCY WITH 50 OR MORE OGGUPANT LOAD, PANIC AND FIRE EXIT HARDWARE SHALL BE PROVIDED ON ALL DOORS VI/LOCKS AND LATCHES PER IBC 1008.1.10. - LAZING AT DOORS SHALL HAVE A LENGTH MEASURED IN THE DIRECTION OF EGRESS TRAVEL OF NOT LESS THAN 44 INCHES I-tR IBC.. 1008.1.6. -WHEN A LANDING SERVES AN OCCUPANT LOAD OF 50 OR MORE, DOORS IN ANY POSITION SHALL NOT REDUCE THE LANDING TO LESS THAN ONE-HALF ITS REQUIRED WITH IBC 1008.1.6. LIGHTING ENERGY CALCULATION REVISIONS No changes sholl bn made to the scope of kvork ‘,vithoi1 prior approval of Building Division. i'eviscrie will require a new plan submittal al id may incudo additional pian review fees. PER MEG 2012 EDITION TABLE G40552 (1) INTERIOR LIGHTING SUMMARY - SPACE BY SPACE TOTAL ALLOWED WATTS: 0.q5 WATT x 3qI SF = 311 WATTS -.T0tLNATT5 PROPOSED = 232 (EX) LOADING DOCK SEPArl.A.TE PERMIT REQUiRED FOR: EAloctlanical aEle,etrical El'Plumbing czi,Gas Piping aty of Tukwila DIVISION LOUVER SCHEDULE FEB 06 2018 RECEIVED CITY OF TUKWILA JUN la 2016 PERMIT CENTER 10L0' x 10'-0", ALUM, SCREEN ON INSIDE, MOTORIZED DAMPER, c16.q 5F MIN NET AREA OF THE INTAKE ORIFICE FOR WINTER TIME OPERATING ABT. < +5 DEG G VERIFY SIZE AND LOGATION 81-0" x 121-0", ALUM, SCREEN ON INSIDE, MOTORIZED DAMPER, c16.01 SF MIN NET AREA OF THE INTAKE ORIFICE FOR SUMNER TIME OPERATING ABT. +5 DEG G VERIFY SIZE AND LOCATION. cr. ,r ••••-•••+9 tr:' LAN !. APPR!....!Er.) • chanpes be iTode to these plans without opproval from the Planning Division of DCD 0110 FOR COMPLIANCE APPROVED 11.114 24 2016 . 7/711-71- octutaiicta $UILDING DIVISION 10 8 6 5 4 3 6-10-16 DELETE GMU MU_ 2 06-01-16 AGENCY REVIEW RESPONSES 4 OR CHANGES 04-27-16 PERMIT SUBMITTAL NO. DATE DESCRIPTION REVISIONS SHEET CONTENTS: PLANS, SECTIONS, SCHEDULES JOB NO.: 2016.05.6 DRAWN BY: DGF CHECKED BY: TX DATE: 4-26-16 SHEET NO. A1.1 HARTUNG GLASS TENANT IMPROVEMENT -BLOWER ROOM GENERAL NOTES OWNER/CONTRACTOR COORDINATION NOTES I PLEASE NOTIFY ARCHITECT IF ANY DISCREPANCIES EXIST WITHIN THE DRAWINGS. 2 THE DRAWINGS FOR THIS PROJECT ARE CONSIDERED TO BE "OWNER/BUILDER TYPE" AND ARE INTENDED TO DOCUMENT THE GENERAL CONSTRUCTION SYSTEMS WHICH MEET MINIMUM BUILDING CODE STANDARDS. CHANGES IN TIBE SYSTEMS MAY RESULT IN CONSTRUCTION THAT DOES NOT MEET MINIMUM CODE OR CONFLICTS WITH OTHER WORK STANDARDS. ANY CHANGES NOT APvKOVED IN WRITING ARE THE RESPONSIBILITY OF THE CONTRACTOR OR SUB -CONTRACTOR MAKING THE CHANGES. 3 THE CONTRACTOR AND SUB -CONTRACTOR SHALL CAREFULLY STUDY AND COMPARE THESE DRAWINGS WITH EACH OTHER AND WITH INFORMATION FURNISHED BY THE TENANT. ANY ERRORS, INCONSISTENCIES OR OMISSIONS DISCOVERED SHALL BE REPORTED TO THE ARCHITECT IMMEDIATELY IN WRITING. THE CONTRACTOR SHALL NOT BE LIABLE FOR THE ABOVE UNLESS THE CONTRACTOR (SUB) RECOGNIZED SUCH ERROR, ETC., DID NOT REPORT SUCH ERROR AND PROCEEDED WITH THE CONSTRUCTION. INSTALLATION DRAWINGS FURNISHED BY THE TENANT TAKE PRECEDENCE OVER THESE DRAWINGS. 4 CONTRACTOR, SUB -CONTRACTOR d MATERIAL SUPPLIERS TO VERIFY FIELD CONDITIONS WHICH EFFECT THEIR WORK PRIOR TO FABRICATION OR CONSTRUCTION. CONTACT INFORMATION INDEX OF DRAWINGS RONHOVDE LARCH ITECTS L L C 4x00 INTERURBAN AVE SOUTH SUITE 138 TUKWILA, WASHINGTON (18168 (206) 859-5500 I FAX (206) 851-5501 ronhovdearch - mom THE FOLLOWING NOTES SHALL SERVE A5 A GUIDE TO THE CONTRACTOR TO VERIFY EACH CONDITION EITHER THE PRODUCT MANUFACTURER OR SUPPLIER, AND/OR LOCAL JURISDICTIONS FOR THEIR REQUIREMENTS PRIOR TO SUBMITTING A BID TO THE OWNER OR PROCEEDING WITH THEIR WORK. THE ITEMS OUTLINED BELOW ARE NOT INTENDED TO BE AN EXHAUSTIVE ANALYSIS OF ALL POSSIBLE AREAS OF CONCERN OR CONFLICT, BUT RATHER TO SERVE A5 A BEGINNING POINT IN IDENTIFYING COMMONLY OVERLOOKED AREAS IN THE CONSTRUCTION PROCESS. BUILDING TENANT ARGHITEGT HARTUNG GLASS TEL: 253 310 3514 CONTACT: KEN MASON KMASON@ HARTING-GLAS5.GOM I. REVIEW MANUFACTURER'S PRODUCT LITERATURE AND GENERAL NOTES FOR INSTALLATION INSTRUCTIONS UNIQUE TO THE PROJECT. THE RONHOVDE ARCHITECT LLG 14100 INTERURBAN AVE. SOUTH #138 TUKWILA, WA 18168 TEL: 206-851-5500 FAX: 206-851-5501 CONTACT: TORJAN RONHOVDE TORJAN@ RONHOVDEARGH I TECTS.GOM G5 COVER GI II=ET, SITE PLAN, AND PROJECT NOTES Al.! PLANS, SECTION, AND SCHEDULES A2.1 DETAILS JAN RO DE E OF WASHINGTON 2. COORDINATE WITH THE FOLLOWING UTILITIES AND COMPLY WITH LOCAL JURISDICTIONAL REQUIREMENTS. A. POWER 3, THE FOLLOWING ITEMS SHALL BE DEFERRED SUBMITTALS. THE CONTRACTOR SHALL PROVIDE A COMPLETE SYSTEM TO THE OWNER AND BUILDING DEPARTMENT WHICH COMPLIES WITH ALL JURISDICTIONAL REQUIREMENTS. 5 SHOP DRAWINGS, PRODUCT DATA AND SAMPLE APPROVAL ARE THE RESPONSIBILITY OF THE GENERAL CONTRACTOR. DO NOT SCALE THE DRAWINGS. 6 UNLESS OTHERWISE NOTED, PLANS ARE DIMENSIONED TO FACE OF STUDS. 1 VERIFY ALL ROUGH -IN DIMENSIONS FOR EQUIPMENT PROVIDED IN THIS CONTRACT OR BY OTHERS. 8 VERIFY SIZE 4 LOCATION OF 4 PROVIDE ALL OPENINGS THROUGH FLOORS 4 WALLS. FURRING CURBS, ANCHORS, INSERTS, MACHINE BASES AND ROUGH BUCKS 4 BACKING FOR SURFACE -MOUNTED ITEMS. JOIST NOTCHING AND HOLE BORING SHALL COMPLY WITH IBC AND/OR JOIST MANUFACTURE. 1 REPETITIVE FEATURES ARE OFTEN DRAWN ONLY ONCE 4 SHALL BE COMPLETELY PROVIDED AS IF DRAWN IN FULL. ITEMS REFERRED TO A5 SINGLE MAY BE PLURAL. 10 VERIFY LOCATIONS OF ALL EXISTING UTILITIES PRIOR TO CONSTRUCTION. I. MEGH SYSTEM 2. FIRE SPRINKLER SYSTEM 3. FIRE ALARM SYSTEM 4. LIGHTING DESIGN 5. PLUMBING SYSTEM 6. ELECTRICAL PERMIT PROJECT INFORMATION BUILDING OWNER SGIOLA FAMILY PROPERTIES 11830 W VALLEY HWY TUKWILA, WA 18188 ACCESSIBILITY COMPLIANCE NOTES I) ALL EXISTING ROUTES OF TRAVEL TO 4 FROM THE BLDG ARE HANDICAP ACCESSIBLE TO H/G PARKING 4 PUBLIC RIGHT OF WAY. NO SITE CHANGES ARE PROPOSED. SCOPE OF NORK: PARCEL NUMBER : SITE ADDRESS : BUSINESS NAME: TYPE OF BUSINESS: JURISDICTION: ZONING: SITE AREA: BUILDING AREA: THE SCOPE OF THIS PROJECT 15 PROVIDE A 460 5.F. BLOWER ROOM WITHIN AN EXISTING GLASS MANUFACTURING FACILITY. 362304-1081 11150 NEST VALLEY ROAD TUKWILA, NA (18188 HARTUNG GLASS MANUFACTURING (EXISTING) LEGAL DESCRIPTION ENERGY CODE SUMMARY 2012 W.S.E.G. CLIMATE ZONE 5 AND MARINE 4. CITY OF TUKWILA G/LI 130,846 5F (3 ACRES) 1ST FLOOR WAREHOUSE: 54,360 5.F. 1ST FLOOR RETAIL: 15,884 5.F. (ADJACENT TENANT) MEZZANINE OFFIIGE/STORAGE: 14,120 5.F. TOTAL: 84,164 5.F. (EXISTING NO CHANGE),. REVISIONS No changes shall be made to the scope of work without prior approval of Tukwila Building Division. NOTE: Revisions will require a new plan submittal and may include additional plan review fees. PARCEL 362304-1011 LOT I OF RENTON SHORT PLAT NO 346-1q REG NO 1101161001 5D PLAT DAF - POR GL 2 4 NE 1/4 OF NW 1/4 5D 5EG LY ELY OF NEST VALLEY ROAD 4 WLY OF PSE RAI 6 LY NLY OF LN NCH 15 156 FT N OF MEAS AT R/A THOF 6 PLT N LN OF 5 180 TH 5T LESS POR GOW FOR SR 181 NUMBER OF STORIES: BUILDING HEIGHT: TYPE OF CONSTRUCTION: I + MEZZANINE (EXISTING) 28' (EXISTING) 3-B, SPRINKLED (EXISTING) PLANK/NE: APPR:9: No changes can be madeto thele plans without approval from the Planning Division of DCD SEPARATE PERMIT REQUIRED FOR: "@Jiochanical isf,Electrical Plumbing LMgGas Piping City of Tukwila BUILDING DIVISION C%) J � 1==Z >u n'illmw ,,,„ g 2 2 i ..., ,.... co W p >" IZ IA= 0 � O Jw� MQ Q �- 0 1=, a= m > 77" Z 2 T =1=0 Z BYO 1,.... Z z tiI < a3 0 m to In= as W r v/ H � NO CHANGE OR ALTERATION PROPOSED TO EXISTING BUILDING ENVELOPE OCCUPANCY CLASSIFICATION: CHANGE OF U5E: EXISTING PARKING: GOVERNING GODES: B AND F-2 (EXISTING, NO CHANGE) Approved By: NO (NO CHANGE PROPOSED OR REQUIRED) `� I. 2012 INTERNATIONAL BUILDING CODE (IBC) WAG 51-50 2.2012 INTERNATIONAL MECHANICAL CODE (IMG) WAG 51-52 3.2012 INTERNATIONAL FIRE CODE (IFC) WAG 51-54 4.2012 UNIFORM PLUM3ING CODE (UPC) WAG 51-56, 51-51 5. 2012 WASHINGTON STATE ENERGY CODE (15EG) WAG 51-11 6.200q ICG/ANSI AII1.1 (ACCESSIBLE STANDARDS + WAG 51-50 + CHAPTER 10 AND II OF THE 2012 IBC) PROJECT VALUATION: $2opoo Th PROPERTY LINE (APPROX LOCATION) s e s FILE COPY Parer No. PRP -- O I I O Pian :° ori wappmvFd is subject to errors and om sion3. Approval of construi. Zion documents doe„, s oy at thorizo tl�e vioiaan o n fnddci tod cod° or ordinance. Receipt of approvod Fi sid Copy and cone {bons i , acknow! ted: Date: L2O /6. (EX) GONG. DEMISING WALL FEB 06 2010 City of Tukwila BUILDING DIVISION NO WORK PROJECT LOCATION (EX) GLASS MANUFACTURING FACILITY (EX) LOADIING DOCK REVIEWED FOR {CODE COMPLIANCE APPROVED JUN 132016 a a O a O O a a a (EX) 1ST FLR: RICH'S, RETAIL SPACE (EX) MEZZANINE: 24-1 PROTECTION, RETAIL SPACE (EX) MEZZANINE: HARTUNG GLASS, OFFICE SPACE r ti y LI (EX) OFFICE 1 ,2 VICINITY MAP RECEIVED CITY OF TUKWILA wi.,f rzf `✓ t gin„M..a: s ::i: i.,. /r/ib/r/eosv/iaurrLiia/474,7v07/7..40,tHriarrrpi/rr0 A 1 JUN 0:1 2016 PERMIT CENTER (EX) PARKING a J I a ✓ / iiimiaiaiao/ diomiH ad/lr /ii/aamI5 r%ai*z., /�////%%T%//',Z!. //9/%/////%%f//%//.Glias:G ////%/1 li/////////%////bY.l%///////.!b/i/. ,7:=#"=;yJi7%%//%/ d////7//474/.. JU///////%%//////4/////J///i/.. ri /H////H%%4W/// i%%%/////H%/ - ,'T////////////4 / 2 06-01-16 04-21-16 : , i 11111111111111111111111111 (EX) PARKING s 1111111111111111111111110 111111111111111111111•0 ROJECT :OC TION v33t o Wholesite c, PROHtRTY LINE (APPROX LOCATION) SITE/OVERALL FLOOR PLAN SCALE: I" = 301-0" REVISIONS SHEET GONTENTS: AGENCY REVIEW RESPONSES Q OWNER CHANGES PERMIT SUBMITTAL IDESGRIPTION COVER SHEET SITE PLAN PROJECT NOTES JOB NO.: 2016.05.G DRAWN BY: DGF GHEGKED BY: TJR DATE: 4 -26 -lb SHEET NO. CS (EX) GONG. WALL (EX) WOMEN r) 7.7 0 (EX) MEN 1\- 1 x z -(EX) SCREEN 1i II 7l.T.FF=199 /111111111 LLLUIILUJ� (EX) GONG. WALL 0,—(Ex) GOL 1 J ::'-nt~xt.xrttnturrrtrt;rrrrrnrMILE .;ar n i APLAN 2DESCALE: v;:14.119 ! (EX) FLOOR DRAIN a (----i (4) 4" x 48" SUSPENDED STRIPLIGHT, (2) F32T8 LAMP, LITHONIA G-2-32 (OR SIMILAR) - 58 WATTS (EX) GONG. WALL' EXE? WOMEN :........._........i X GLASTON FG500 BY OTHERS 0 r<, I L Co1<. Loi (EX) GOL� x 101-011 b'43,II AGGE55 OPNG. ....................... INTAKE LOUVER \% CENTER OPENING BETWEEN ROOF PURLINS AND BLOWER UNIT BELOW. SEE DEFERRED MEGH. SUBMITTAL DEFLECTION TRACK, TYP BLOWER BY OTHERS VERIFY LOCATION AND CLEARANCES (EX) ROOF DECK AND COVERING '.;t. — _r g• I • 11 r l r r A '4 N, 410 '4 ,; • BLOWE SEE 01 ADD (2) 2x6 HF#2 EACH SIDE OF NEW OPNG. STEEL I• BOX BEAM HEADER --- 1 GONG. SLAB > Q TYP. WALL ASSEMBLY: b" Sit STUD (6005125-68) AT lb" O.G. WITH 5-1/2" SOUND ATTENUATION INSULATION AND 5/8" TYPE 'X' GWB EA. SIDE. BLOWER 9— m ROOM - �- // -r / �/Y / --,'(/ \(EX) BLOWER BY OTHERS INSTALL ON SPRING VIBRATION ISOLATION MOUNTS WITH MIN. 2 i STATIC DEFLECTION \ \/ \\ / �// zz/ \r\�- / 2 SECTION A SCALE: 1/4" - 1-0 (EX) ROOF PURLINS (EX) ROOF BEAM DUCTWORK ERRED MECHANICAL SUBMITTAL. SAW GUT (ENTIRE DEPTH OF EXISTING SLAB) AROUND THE FOOTPRINT OF BLOWER ROOM TO PROVIDE STRUCTURAL BREAK BETWEEN BLOWER ROOM AND REST OF BUILDING. 4 L_0 VI E.'..'l"'3' NR,1 _ rir � vprrnruriiiinnillyiiil /d//H///.0//l//1/44 G fe.raAVASVAMTOMMONXIMSFAMMAMVAIN.WOONAP' 21-2" lniiayr/aai i%r%.. gyeememmmi 01 51 er//Nl'%//////%%!:Luff%/H.{!U///N////.f0/.4'j///r/.W.H///////ti. rarrmrr✓rrrrm/rnmrmliiiiiiii—r%U///%%iign r,Ao/m ,, rjI 1 f //'ryr/•;i:11,,,:tL.4...,,,,,,,r,L,,,,,,0 3 y/fs.I rrrrr r ` rrrarr—„ rrr (l (EX) ADJACENT TENANT RETAIL SPACES (EX) GONG. DEMISING WALL (EX) MAINT (Ex) coL_N (EX) MAINT (EX) GOL ry--(% GOL (p) MANUFACTURING (EX) LOADING DOCK GENERAL NOTES I. DUCT, PIPING, CONDUIT PENETRATIONS OF THE BLOWER ROOM SHOULD BE MADE WITH A SMALL GAP (LESS THAN 1/4") AROUND THE SYSTEM PENETRATION, AND CAULKED AIR TIGHT USING ACOUSTICAL CAULK, BACKER ROD, AND PACKED INSULATION IN METAL SLEEVE. 2. SERVICE PIPES PENETRATING THE EXISTING CONCRETE DEMISING WALL SHOULD BE SEALED AIR TIGHT WITH ACOUSTICAL CAULK (1/4" GAP AROUND PIPE). 3. ALL DUCTS EXPOSED TO WORKING AREA SHOULD BE CONSTRUCTED OF A MIN. lb GAGE SHEET METAL AND EXTERNALLY WRAPPED WITH 2 LB/5F LAGGING MATERIAL (SOUNDSEAL B-20/QFA-3). SCC DEFERRED MECHANICAL SUBMITTAL. DEMO FLAG NOTES REMOVE OVERHEAD ROLL -UP DOOR AND FRAME REMOVE WOOD STAIRS REMOVE OFFICE WALLS, CEILING, DOORS, FINISHES, AND ELECTRICAL REMOVE PORTION OF GHAINLINK SCREENING FENCE SAWGUT EXISTING GONG. SLAB (ENTIRE THICKNESS) AROUND FOOIVRINT OF PROPOSED BLOWER ROOM TO PROVID TRUG BREAK EN I ; OWER ROOM AND THE REST OF I E BUILDI REMOVE PORTION OF ROOF DECK AND COVERING FOR NEW INTAKE LOUVER. VERIFY OPENING SIZE AND LOCATION FLOOR PLAN FLAG NOTES 01 INFILL 10' x 10' OPENING IN EXISTING GONG. WALL WITH 8" GROUT FII I FD GMU BLOCK. O2 4" x 10' x 10' REMOVABLE METAL PANEL, MIN. 42 5TG NOISEBARRIER LLC., QUIETMOD H/P-42 WITH REMOVABLE H -JOINER OR EQ, DOOR SCHEDULE ( I) 3'-0" x 1'-0" x 1-3/4" INSULATED HOLLOW METAL, MIN lb GA STEEL FRAME FULL PERIMETER SOUND SEALS JAMB/HEAD: PEMKO 350_5R NGP 105 MILLED BOTTOM: PEMKO 434_RL OR NGP 423N SURFACED MOUNTED BOTTOM: PEMKO 413I_PKL ADA LEVER HANDLE LOCKABLE HARDWARE GENERAL DOOR NOTES - ALL INTERIOR AND EXTERIOR DOORS NOTED SHALL HAVE LOCKS PROVIDED W/ HARDWARE THAT IS READILY OPENABLE FROM THE EGRESS 51DE WITHOUT THE USE OF A KEY OR SPECIAL KNOWLEDGE PER IBC 1008.I.q -ALL HARDWARE PULLS, ,HANDLES, LOCKS, LATCHES OR OTHER OPERATING DEVICES SHALL NOT REQUIRE TIGHT GRASPING, PINCHING OR TWISTING OF THE WRIST TO OPERATE PER 1BG 1008.1.5.1 - ALL EXTERIOR DOORS TO BE EQUIPPED WITH THRESHOLDS WITH A MAXIMUM RISE OF 1/2' PER ANSI 404.2.4. -ALL DOORS IF NOT SPECIFICALLY NOTED OTHERWISE SHALL BE PROVIDED WITH ADA LEVER HANDLE HARDWARE COMPLYING WITH ANSI 40426. - ALL HARDWARE TO BE MOUNTED WITH OPERABLE PARTS LOCATED BETWEEN 34" AND 48" ABOVE THE FLOOR PER ANSI 40426. - SEE SHEET AI.O FOR LOCATIONS OF DOORS REQUIRED TO BE EQUIPPED WITH EXIT SIGNAGE AND EXIT ILLUMINATION. -DOOR CLOSERS SHALL BE ADJUSTED 50 THAT FROM THE OPEN POSITION OF q0 DEGREE -5, THE TIME REQUIRED TO MOVE THE DOOR TO AN OPEN POSITION OF 12 DEGREES SHALL BE 5 SECONDS MIN. -IN GROUP 'H' OCCUPANCY OR GROUP 'A' OR 'E' OCCUPANCY WITH 50 OR MORE OCCUPANT LOAD, PANIC AND FIRE EXIT HARDWARE SHALL BE PROVIDED ON ALL DOORS W/ LOCKS AND LATCHES PER IBG 1008.1.10. - LANDING AT DOORS SHALL HAVE A LENGTH MEASURED IN THE DIRECTION OF EGRESS TRAVEL OF NOT LESS THAN 44 INCHES PER IBC 1008.1.6. - WHEN A LANDING SERVES AN OCCUPANT LOAD OF 50 OR MORE, DOORS IN ANY POSITION SHALL NOT REDUCE THE LANDING TO LESS THAN ONE-HALF ITS REQUIRED WITH IBC 1008.1.6. LIGHTING ENERGY CALCULATION PER WSEG 2012 EDITION TABLE 6405.52 (I) INTERIOR LIGHTING SUMMARY - SPACE BY SPACE TOTAL ALLOWED WATTS: O.qs WATT x 3441 5F = 371 WATTS TOTAL WATTS PROPOSED = 232 A\ LOUVER SCHEDULE FED 0.6 2010 10'-0" x 10'-0", ALUM, SCREEN ON INSIDE, MOTORIZED DAMPER, 016.6I 5F MIN NET AREA OF THE INTAKE ORIFICE FOR WINTER TIME OPERATING ABT. < +5 DEG G VERIFY SIZE AND LOCATION 8'-0" x 12'-0", ALUM, SCREEN ON INSIDE, MOTORIZED DAMPER, 446.'1 5F MIN NET AREA OF THE INTAKE ORIFICE FOR SUMNER TIME OPERATING ABT. > +5 DEG G VERIFY SIZE AND LOCATION. 1)16 RONHOVDE ARCHITECTS 4 c . 14q00 INTERURBAN AVE SOUTH SUITE 138 TUKWILA, WASHINGTON 18168 (206) 851-5500 I FAX ( 851-5501 ronhrG .com � J cOe== )0- mlas W Y 2 2 ao~ LIJ 0 >• ;21) u= �� m O Jw0 Q >- Q 0 .. Et > 5 Z 1 imul c0 :,,j 0 . iss=Q n ii= o o amJZ � �- i. LO M ZI o a112 r 01) ftz eVi''0 COW °APPROVED AIN 13 2016 City offo la UILDING RECEIVED CITY OF TUKWILA JUN 011 2016 PERMIT CENTER 10 q 8 1 6 5 4 3 2 06 -01 -lb AGENCY REVIEW RESPONSES d OWNER CHANGES 04-21-I6 PERMIT SUBMITTAL NO. DATE DESCRIPTION REVISIONS SHEET CONTENTS: PLANS, SECTIONS, SCHEDULES JOB NO.: 2016.05.6 DRAWN BY: DGF CHECKED BY: TJR DATE: 4-26-I6 SHEET NO. A1.1 INFILL STUD HEADER TRACKS 6005125-54 (50 K5I) WITH (2) #8 SCREWS AT 24" 0.G. HEADER MEMBERS 10005162-54 (50 K5I) (2) BOXED ANGLE 54 MIL WITH (4) #8 SCREWS AT EACH LEG CRIPPLE STUD 6005125-b8 WITH (2) #8 SCREWS JAMB 6005125-68 (50 KSI) (2) BOXED ANCHORAGE (I) 3/5" DIA SIMPSON TITEN HD, WITH 25" NOMINAL EMBEDMENT BOX BEAM HEADER SCALE E : I" - l' -0" 3 -BOX BEAM HEADER FLOOR OR ROOF STRUCTURE 3/4" MAX -} DEFLECTION TRACK W/ 3" LE6 DO NOT ATTACH 61A1B AT DEFLECTION TRACK LE6 FEB O62018 WALL TOP DEFLECTION TRACK SCALE : I-1/2" = I'-0" 805-23 n BASE SEE WALL SCHEDULE I-1/4" RAM -SET GONG. PINS @ 24" O.G. GONG. FLOOR 4'5100 INTERURBAN AVE SOUTH SUITE 138 TUKWILA, WASHINGTON 88168 (206) 85q-5500 I FAX (206) 85q-5501 ronhovdearc a I _,i om AN RO "°: I E OF WASHINGTON f� laMin z>a g§1 W O 8 Oier < Thm. dz Ili I= 0 1— Z w ;ate z iVpROVED lUN 3 '1016 MY �f "1'0 13NisloNusIG ium o.Uzi Z17. RECEIVED CITY OF TUKWILA JUN O.1 Z016 PERMIT CENTER 10 I 8 l 5 4 3 2 06-01-16 AGENCY REVIEW RESPONSES ff OWNER CHANGES 1 04 -21 -Ib PERMIT SUBMITTAL NO. DATE DESGRIPTI ON REVISIONS SHEET CONTENTS: DETAILS JOB NO.: 2016.05.0 DRAWN BY: DCF GHEGKED BY: TJR DATE: 4-26-16 SHEET NO. A2.1