Loading...
HomeMy WebLinkAboutPermit D16-0121 - GATEWAY NORTH / BUILDING 3 - REROOFGA AY NORTH - BLDG 3 3 215 S 116TH ST D16-0121 � City of Tukwila ' �;. Department of Community Development + 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 '' ` Phone: 206-431-3670 Inspection Request Line: 206-438-9350 Web site: http://www.TukwilaWA.gov Parcel No: 0923049066 Address: 3215 S 116TH ST 17��L�1��I�i�il�li�i»:�►�il�� Permit Number: D16-0121 Issue Date: 5/25/2016 Permit Expires On: 11/21/2016 Project Name: GATEWAY NORTH - BLDG 3 Owner: Name: EPROPERTY TAX INC DEPT 207 ' Address: PO BOX 4900 , SCOTTSDALE, WA, 85261 Contact Person: Name: DAN JOHNSON Address: Contractor: Name: 13105 HOUSTON RD E, SUMNER, WA, 98390 WAYNE'S ROOFING INC Address: 13105 HOUSTON RD, SUMNER, WA, 98390-9208 License No: WAYNESR205Q5 Lender: Name: CBRE INC Phone: (253) 863-4455 Phone:(253)863-4455 Expiration Date: 5/2/2017 Address: 20415 72ND AVE S#210 C/0 STOCKBRIDGE CAPITAL GP, KENT, WA, 98032 DESCRIPTION OF WORK: REMOVE EXISTING ROOFINGTO WOOD DECK. INSTALL NEW INSULATED ROOF SYSTEM. TWO LAYERS 2.4" ISO, 1/2" COVER BOARD AND .060 MIL SIKAPLAN PVC ROOF MEMBRANE Project Valuation: $201,096.00 Fees Collected: $4,048.12 Type of Fire Protection: Sprinklers: Fire Alarm: Type of Construction: VB Occupancy per IBC: B Electrical Service Provided by: TUKWILA Water District: TUKWILA Sewer District: VALLEY VIEW Current Codes adopted by the City of Tukwila: International Building Code Edition: 2012 National Electrical Code: 2014 International Residential Code Edition: 2012 WA Cities Electrical Code: 2014 International Mechanical Code Edition: 2012 WAC 296-466: 2014 Uniform Plumbing Code Edition: 2012 WA State Energy Code: 2012 International Fuel Gas Code: 2012 Public Works Activities: Channelization/Striping: Curb Cut/Access/Sidewalk: fire Loop Hydrant: Flood Control Zone: Hauling/Oversize Load: Land Altering: Volumes: Cut: 0 Fill: 0 Landscape Irrigation: Sanitary Side Sewer: Number: 0 Sewer Main Extension: Storm Drainage: Street Use: Water Main Extension: Water Meter: No Permit Center Authorized Signature: I w � Date: �� I I hearby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this development permit and a r o the conditions attached to this permit. Signature: Date: � Z��' p' - > Print Name: C�i� l� �� ���t�1Mbv►J� This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: ***BUILDING PERMITCONDITIONS*** 2: Work shall be installed in accordance with the approved construction documents, and any changes made during construction that are not in accordance with the approved construction documents shall be resubmitted for approval. 3: All permits, inspection record card and approved construction documents shall be kept at the site of work and shall be open to inspection by the Building Inspector until final inspection approval is granted. 4: All construction shall be done in conformance with the Washington State Building Code and the Washington State Energy Code. 5: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of this requirement. 6: Prior to final inspection for this building permit, a copy of the roof inembrane manufacturer's warranty certificate shall be provided to the building inspector. 7: VALIDIN OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 8: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206-431-3670). 9: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center. PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 1700 BUILDING FINAL** 0103 PRE-REROOF CITY OF TUKi�1LA Com�reunity Development Department Public Works Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.TukwilaWA.� SITE LOCATION Building Permit No. ���o — Q ��� Project No. � Date Application Accepted: � — [ a1 �_ Date Application Expires: ( �— �O —(_� or o77tce use CONSTRUCTION PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **Please Print** King Co Assessor's Tax No.: Site Address: � Z � g / i Co � S: %� 1�.....; 14 e.�a� . Suite Number: Floor: Tenant Name: L7'�- ��. w�� J�-� � r�'�. �� New Tenant: ❑..... Yes �. No PROPERTY OWNER Name: � � �Z � Address: Zv y� S � Z.��f /-1 �c $ . City: � �� State: �� Zip: CONTACT PERSON — person receiving all project communication Name: .n._� ,� J a ��..., � � � Address: . _ City: State: Zip: Q S v..-..� � r- ��t �v 3 Phone: _ Fax: Email: GENERAL CONTRACTOR INFORMATION Company Name: �� y� c J % ' � ,.r , Address:l f� � �� City: Sviu .� C � State: �,� ZiP: S, ��, �� �J Phone: �_ � u � � � Fax: Contr Reg No.: ��ry�E� R�s� Exp Date: 5� � o Tukwila Business License No.: H:Wpplications�Forms-Applications On Line�2012 Applications�Permit Application Revised - 2-7-12.docx Revised: February 2012 bh ARCHITECT OF RECORD Company Name: Architect Name: Address: City: State: Zip: Phone: Fax: Email: ENGINEER OF RECORD Company Name: Engineer Name: Address: City: State: Zip: Phone: Fax: Email: LENDER/BOND ISSUED (required for projects $5,000 or greater per RCW 19.27.095) Name: � � 2 � Address: �o�-F!s �7Z,vJ ,,E f• City: �� .� State: � � Zip: �. Page 1 of 4 BUILDING PERMIT INFORMATII - 206-431-3670 Valuation of Project (contractor's bid price): $ Z. c? �� o i te . r� o Existing Building Valuation: $ Describe the scope of work (please provide detailed information): �► /�-C .� o�C C�_ :� i •`.s c r'� C�U fL; � � e 1 Ci Gc� f �.= � iL ..�- v: e.a • i il.J C�) ,f vr u /� iY f i�-<Jb � % •-r � TZ w+ ��.cD'!� �-/+-�� � 'Z `�'i •� �Jt�i //�- <• COv.:� ,�.7n� � s CJ �.. �I . c5 v o /i.-% r / 1C /a p I.. n.+ }� v�_ (' a��F /�`� r� . n.s � Will there be new rack storage? ❑.... Yes ❑..No If yes, a separate permit and plan submittal will be required. Provide A11 Building Areas in Square Footage Below Addition to Type of Type of Existing Construction per Occupancy per Existin Interior Remodel Structure New IBC IBC 15f Floor 2° FloOr 3` Floor Floors thru Basement Accessory Structure* Attached Garage Detached Garage Attached Carport Detached Carport Covered Deck Uncovered Deck PLANNING DNISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact:_ Will there be a change in use? ❑.......Yes ❑.......No If "yes", FIRE PROTECTION/HAZARDOUS MATERIALS: ❑ ....... Sprinklers ❑ .......Automatic Fire Alarm ❑....... None Handicap: ❑....... Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑.......Yes ❑...... No If "yes', attach list ofmaterials and storage locations on a separate 8-1/2" x 11 " paper including quantities and Material Safery Data Sheets. SEPTIC SYSTEM ❑.......On-site Septic System — For on-site septic system, provide 2 copies of a current septic design approved by King County Health Department. H:Wpplications�Forms-Applications On Line�2012 Applications�Permit Application Revised - 2-7-12.docx Revised: Febniary 2012 Page 2 of 4 bh •a � PUBLIC WORKS PERMIT INFO_ �ATION — 206-433-0179 Scope of Work (please provide detailed information): Call before you Dig: 811 Please refer to Public Works Bulletin #1 for fees and estimate sheet. Water District ❑ .. Tukwila ❑ ... Water District # 125 ❑ ... Highline ❑ .. Water Availability Provided Sewer District ❑ .. Tukwila ❑ ...Valley View ❑... Renton ❑.. Sewer Use Certificate ❑...Sewer Availability Provided ❑... Renton ❑... Seattle S�e tic Svstem: ❑ On-site Septic System — For on-site septic system, provide 2 copies of a current septic design approved by King County Health Department. Submitted with Application (mark boxes which applvl: ❑.. Civil Plans (Maximum Paper Size — 22" x 34") ❑.. Technical Information Report (Storm Drainage) ❑... Geotechnical Report ❑.. Traffic Impact Analysis ❑ .. Bond ❑... Insurance ❑... Easement(s) ❑... Maintenance Agreement(s) ❑ .. Hold Harmless — (SAO) ❑ .. Hold Harmless — (ROW) Proaosed Activities (mark boxes that applv): ❑.. Right-of-way Use - Nonprofit for less than 72 hours ❑... Right-of-way Use - Profit for less than 72 hours ❑.. Right-of-way Use - No Disturbance ❑... Right-of-way Use — Potential Disturbance ❑ .. Construction/Excavation/Fill - Right-of-way ❑ Non Right-of-way ❑ ❑ .. Total Cut cubic yards ❑ .. Total Fill cubic yards ❑ .. Sanitary Side Sewer ❑ .. Cap or Remove Utilities ❑ .. Frontage Improvements ❑ .. Traffic Control ❑ .. Backflow Prevention - Fire Protection Irrigation Domestic Water ❑... Work in Flood Zone ❑ ... Storm Drainage ❑... Abandon Septic Tank ❑... Curb Cut ❑... Pavement Cut ❑... Looped Fire Line - >, ❑.. Permanent Water Meter Size (1) " WO #_ ❑.. Temporary Water Meter Size (1) " WO # �❑.. Water Only Meter Size........... " WO # ❑.. Sewer Main Extension............ Public ❑ Private ❑ ❑.. Water Main Extension............ Public ❑ Private ❑ ❑... Grease Interceptor ❑... Cha�nelization ❑...Trench Excavation ❑...Utility Undergrounding (2) " WO # (3) " WO # (2) " WO # (3) " WO # _ ❑ .. Deduct Water Meter Siae " FINANCE INFORMATION Fire Line Size at Property Line Number of Public Fire Hydrant(s) ❑ .. Water ❑ .. Sewer ❑ .. Sewage Treatment Monthly Service Billin� Name: Mailing Address: Water Meter Refund/Billine: Name: Mailing H:Wpplications�Forms-Applications-On Line�2012 Applications�Permit Application Revised - 2-7-12.doc�c Revised: February 2012 bh Day Telephone: c��y Day Telephone: Ciry State Zip State Zip Page 3 of 4 ,► PERMIT APPLICATION NOTES - Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR AU�H�I�D AGENT: Date: ,J " j v ` � � Print Name: LJ.�,� T� ��v�;,,J Day Telephone: ��� !� oca i'� �(y Mailing Address: �.�� o,_S�` �-¢���� �,� �-�! . � �v�� -�``-� w/; - � u�s�! City State Zip H:Wpplications�Forms-Applications On Line�2012 Applications�Pertnit Application Revised - 2-7-12.docx Revised: February 2012 Page 4 of 4 bh ► Date Paid: Tuesday, May 10, 2016 Paid By: WAYNE'S ROOFING INC Pay Method: CHECK 8598 Printed: Tuesday, May 10, 2016 10:17 AM 1 of 1 ���� SY57EM5 l ..- — PE TION RECORD � INS C ��_��Zf � / Retain a copy with permit INSPE ON N0. PERMIT N0. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 �Approved per applicable codes. � Corrections required prior to approval. U paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. � � INSPECTION RECORD � Retain a copy with permit ��6�� �� IN CTION N0. PERMIT N0. CITY OF TUKWILA BUILDING DiVI510N 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 � Approved per applicable codes. a Corrections required prior to approval. COMMENTS: � Inspector: Date: � � � - l /' l� � REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. 1NSPECTI4N RECORD 6 Z 2 Retain a copy with permit ➢r� �' r INSPECTION N0. PERMIT N0. CITY OF Tl1KWILA BUILDING 6300 Southcenter Blvd., #100, Tukwila. WA 98188 Permit lnspection Request Line (206) 438-9350 DIVISION (206) 431-3570 � � Approved per applicable codes. � Corrections required prior to approval. iOMNiENTS: �v� � C nspettar: � REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 630Q Southcenter Slvd., Suite 100. Call to schedule reinspection i� INSPECTION RECORD �f� ��(� � � Retain a copy with permit SPECTION N0. PERMIT N0. CITY UF TUKWILA BUILDING DIVISI�N 6300 Southcenter 8{vd., #100, Tukwila. WA 98388 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 �App�oved per applicable codes. �Corrections required prior to approval. COMMENTS: pector: � "") ` �.. !� 1p � REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at h300 Southcenter Blvd., Suite 100. Catl to schedute reinspection. A . � '� _ ----�- --`�T_ ....---" „'�•-�� , ^ _, � � -- --� � Samafi/� BUILDING TRUST � 20 Year System Plus Warranty Warranty Serial No.: 0000026360-245216.1 SIKAPLAN ROOFING WARRANTY FOR COMMERCIAL BUILDING Building Owner: RREEF America Reit II Corp MMMM7 Washinqton Building Name: Gatewa North Buildin 3 Building Address: 3215 South 116th Street Tukwila WA 98168-1973 Applicator: Wa ne's Roofin Inc. 13105 Houston Road Sumner WA 98390 Telephone: (253) 863-4455 Date of Substantial Completion: 7/28/2016 Date of Inspection: N/A By: N/A Building/Area Name: Gatewav North Buildina 3 Used As: INDUSTRIAL BUILDINGS - WAREHOUSES Area Warranted: 32.330 sq. ft. Sika Corporation ("Sika"), warrants to the building owner described above ("Owner"), that subject to the terms, conditions, and limitations, including the limitations set forth in section 10 below, stated herein, Sika Corporation will repair roof leaks originating from the Sikaplan Roofing Membrane, Sarnatherm Insulation or Sika Corporation Roofing Accessories installed according to Sika Corporation's Technical instructions by a Sika Corporation Authorized Roofing Applicator for a period of 20 (twenty) years commencing with the date of substantial completion of the installation of the Roofing Membrane with no monetary limit with respect to roof repair costs. p TERMS, CONDITIONS, LIMITATIONS 1. Owner shall notify Sika Corporation on the first business day immediately following the discovery of each leak in the Roofing System and confirm in writing within one week. 2. If on Sika Corporation's inspection, Sika Corporation determines that the leak is caused by a defect in the Sikaplan Roofing Membrane, Samatherm Insulation or Accessory provided by Sika Corporation to the Applicator for this building or from a defect in the Sika Corporation Authorized Applicator's workmanship applied to that Sikaplan Membrane, except as provided in the following paragraph three (3) Owner's remedies and Sika Corporation's Iiability shall be limited to Sika Corporation's repair of the Roofing Membrane, Sarnatherm Insulation or Accessory. 3. This warranty does not apply and may be null and void if any of the following occur: (a) The Roofing Membrane, Sarnatherm Insulation or Accessory is damaged by a natural disaster including, but not limited to, earthquake, lightning, hail, peak wind gust in excess of 60 mph (97 km/h), hurricane, or tornado, as defined by The National Weather Service, or other acts of God, or: (b) The Roofing Membrane, Sarnatherm Insulation or Accessory is damaged by any act of negligence, accident, or misuse including, but not limited to, vandalism, falling objects, civil disobedience, or act of war, or: (c) A deficient pre-existing condition or equipment is causing water entry, or: (d) Metal work or other accessories or equipment is used in the Roofing and causes leaks, or: (e) There are any alterations or repairs made on or through the completed roof, or objects such as but not limited to fixtures, equipment, or structures are placed on or attached to the completed roof without first obtaining written authorization from Sika Corporation, or: (f) Failure by the Owner or his lessee to use reasonable care in maintaining the roof as described in the Owner's Guide provided with this warranty, including that of sealants and caulking, or: (g) Loss of integrity of the building envelope and, or structure including, but not limited to partial or complete loss of roof decking, wall siding, windows, doors or other envelope components or from roof damage by wind blown objects, or: (h) Condensation accumulates in the roof assembly due to incorrect design or due to a reduction in the vapor barrier effectiveness, or: (i) A significant change in the use of the building by the Owner or his lessee expected by Sika Corporation to effect the Roofing Membrane as originally installed, or: (j) The Roofing Membrane is damaged by contaminates and/or spills, or: (k) Deficient design applied to the Roofing Membrane such as membrane contact with incompatible materials andlor substrates, or: (I) The Owner fails to comply with every term and condition stated herein. 4. During the period of this warranty, Sika Corporation , its agents and employees, shall have free access to the roof during regular business hours. 5. Should the Roofing Membrane be concealed, the cost of exposure of the Roofing Membrane for purposes of Sika Corporation's investigation and/or repair, such as removal and replacement of any paving or overburden, shall be the Owner's responsibility. 6. Sika Corporation shall have no obligation under this warranty until all invoices for materials, installation, and services provided by Sika Corporation and the Sika Corporation Authorized Applicator have been paid for in full. 7. Sika Corporation's failure at any time to enforce any of the terms or conditions stated herein shall not be construed to be a waiver of such provision. 8. This warranty may be tr�nsferred to a subsequent Owner of the Building if approved in advance and in writing by Sika Corporation and the cost to process the transfer and to inspect and repair the Sika Corporation Roofing System, if necessary, such as but not limited to, removal and replacement of overburden, shall be the Owner's responsibility. 9. The Owner and Sika Corporation hereby agree that any and all claims (contractual, statutory, common law or otherwise), disputes, or suits that in any way, directly or indirectly, arise out of or relate to this Warranty, or the alleged breach thereof, or to any contracts between the owner and Sika Corporation , or the alleged breach thereof, or to the design, manufacture, sale, distribution, installation, and/or inspection of the Sikaplan Roofing System, shall first be submitted to non-binding mediation before a neutral mediator jointly selected by the parties or, in the absence of agreement, as designated by the American Arbitration Association. In the absence of resolution by mediation, all such claims shall be settled by arbitration by the American Arbitration Association in accordance with the Construction Industry Arbitration Rules. Any such mediation and/or arbitration shall take place in Boston, Massachusetts. This Warranty, and any claims, disputes or suits beriveen the parties hereto shall be governed by, and construed and enforced in accordance with, the laws of the Commonwealth of Massachusetts. 10. THIS WARRANTY IS GIVEN IN LIEU OF ALL OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING ANY WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTfCULAR PURPOSE. THERE ARE NO WARRANTIES TkiAT EXTEND BEYOND THE DESCRIPTION ON THE FACE HEREOF. THE REMEDIES STATED HEREIN ARE EXCLUSIVE REMEDIES AND SIKA CORPORATION SHALL NOT BE RESPONSIBLE OR LIABLE FOR ANY INDIRECT, CONSEQUENTIAL OR INCIDENTAL DAMAGES INCLUDING THE PRESENCE OF MOLDS, FUNGI, BACTERIA, SPORES, MYCOTOXINS OR THE LIKE OR FURTHER LOSS OF ANY KIND WHATSOEVER, INCLUDING BUT NOT LIMITED T0, DAMAGE TO THE BUILDING ON WHICH THE COMPONENTS OF THE ROOF ARE SITUATED, DAMAGE TO THE CONTENTS THEREOF, LOSS OF USE OF THE BUILDING OR ANY COMPONENT PART THEREOF, OR DAMAGE TO ANY OTHER PROPERTY OR PERSONS. NO REPRESENTATIVE OF SIKA CORPORATION HAS AUTHORITY TO MAKE ANY REPRESENTATIONS OR PROMISES EXCEPT AS STATED HEREIN. This Warranty Is Effective From: 7I28/2016 through: 7I28I2036 � � I� �"''i, '� � �`� 812412016 � Luz Adorno-Boria Date: Brian J. Whelan Administrative Assistant Executive Vice President ��L������ CITY QF TUKV'VILA SIKA CORPORATION • ROOFING 100 Dan Road • Canton, MA 02027 Tel : 781828-5400 • Fax: 781-828-5365 • usa.sarnafil.sika.com SEP 13 2016 aERMIT CE��TER Page 1 of 1 �i� --��I�-� 8/24/2016 Date: � . • � 4 t Wayne's Roofing, Inc. 13105 Houston Road Sumner, WA 98390 www.wavnesroofina.com SUBMITTALS ���r^^!',T� P���iIT � �..o�u;a,IC 1+.. (��M� chanic�! Cy�l��tricai G�.y of Tukwil� �'� �°_ � °�" �r ��v�s�i Section 07550 - PVC Single-Ply Roofing PROJECT GATEWAY NORTH BLDG 3 321�116th Street Tukwila, WA PREPARED FOR CBRE 20415 72nd Ave South Kent, WA REVISIONS No changes shall ba made to thP sc of t�rork ���ith�ut prior �pprovat of ►'u';!•�ila E3uilding Division. ����=: ��v��i��� u�ill require a new plan sul �nd muy in�Su�e add:tional p;an review fe ` tiil:tiE� �iixlf IRG. 1\-C � �VMNLN.No April28tli, 2016 �� C�Op�I G������ c�oo � I �_ D,��-�l , FI^� rW�f����� �p�ro��l is subje� to �reors and omi�sions. l,;�-�J�a��9 c� �;��s�����,i�� dc�cuments does not �u€�o�iz� t:�� �;���ti��n �� �;�;r �c���t�ci �de or ordinance. ���ci�t o� ����; QqJc�S Ft�E� C�py and conoii;��s �r �know�ed��d: �y: � Da2e: �' �-i� • �C.. clty Of �'ul�11� ������� �������� ��c�i�c� �IYY 0� YU�l�lIL� N1AY 10 2016 ����eg c����� WR/ PROJECT 16-032 SUMNER (253) 863-4455 SEATTLE (206) 575-0078 FAX (253) 863-8311 a t Wayne's Roofing, Inc. 13105 Houston Road Sumner, WA 98390 www.wavnesroofina.com wati�res�txm�:, �sc� � � �a �� YUMNGM,riO Gateway North Bldg 3 DRAWINGS ■ Roof Plan ■ System Descriptions PRODUCT DATA ■ Roof System Product Data CERT/FICATION ■ Approved Applicator Letter ■ Roof System UL Rating WARRANTIES ■ Manufacturers Sample Warranty ■ Contractor's Sample Warranty April 28, 2016 1 2 3 4 WRI PROJECT 16-032 � 8�-0• . Insulation Data . . . o Notes: MANUFACTURER � - Perimeter & Corner Areas , � � are Determined in Accordance TYPE with ASCE-7: Field Layout 1/10 Least Plan Width or THICKNESS 6 FAST/BD 4/10 Roof Height but not Less than 4 Ft R-VALUE (Total R=40.9) 8'- O' • • • • • - Where Parapet exceeds 36" NO. OF LAYERS � Corner Fastener is not needed i � ATTACHMENT . . . . . FASTENER TYPE Perimeter Layout 10 FAST/BD FASTENER LENGTH 8�-�" � � � � BOARD SIZE O. . . . � � • • • . FIELD FAST'G • . . . PERIMETER FAST'G CornerLayout 16 FAST/BD CORNER FAST'G INSULATION FASTENING PATTERN FM R�Q(PATfERN ONLY) Sarnafastener XP (Fastener will Penetrate Deck by Much as 2") Bottom SARNAFIL SARNATHERM POLYISO 2.4 INCH Middle SARNAFIL SARNATHERM POLYISO 2.4 INCH 13.8 13.8 SINGLE SINGLE LOOSE LOOSE N/A N/A N/A N/A 4X8 4X8 N/A N/A N/A N/A N/A N/A N/A N/A Top - SARNAFIL SARNATHERM ROOF BOARD -H 1�2„ 2.5 : SINGLE MECHANICAL SARNAFASTENER XP 7 INCH 4X8 6 10 16 1-75 �--SikaPlan Energysmart.60 mil Roof — — Membrane (Heat Welded) (White) Induction Welded RhinoBond Assembiy ������ ������ �ORRECTION LTR# BASE FLASHING COMPONENTS Sarnatherm Roof Board-H hanically Attached) iarnatherm 20 psi Polyiso Insulation �e Laid) iarnatherm 20 psi Polyiso Insulation e Laid) ng Wo��EIVED CITY OF TUKWILA MAY 2 0 2016 r— Sarnafil G459 flashing .60 mil Roof Membrane Adhered) (White) Sarnaco12170 � � Adhesive � �� � ♦ � ' Wayne's Roofing, Inc. �3�os Housto� Road GATEWAY NORTH BLDG 3 Sumner, WP, 98390 5um (253) 863-4d55 Sea (206) 5754078 Fax (253) 863-8311 Gate Prepared By Rev. 4-28-16 T.L. SYSTEM DESCRIPTION .ob No. Scale Section 16-032 N.T.S. Sheet 002 Wayne's Roofing, Inc. 13105 Houston Road Sumner, WA 98390 www.wavnesrooflng.com wxti�rEs A�wnu:, ���c � '1VNM[M.wc DRAWINGS ,y e�-o• Insulation Data . . . b Notes: MANUFACTURER � - Perimeter & Corner Areas � � � are Determined in Accordance n'PE with ASCE-7: Field Layout 1/10 Least Plan Width or THICKNE55 6 FAST/BD 4/10 Roof Height but not 8,_ p. Less than 4 Ft R-VALUE (Total R=40.9) • • • • • - Where Parapet exceeds 36" NO.OF LAYERS b Corner Fastener is not needed d ATTACHMENT . . . . . FASTENER TYPE Perimeter Layout 10 FAST/BD FASTENER LENGTH 8' - O' b � � � � BOARD 512E � . . . . FIELD FAST'6 . . . . PERIMETER FAST'6 CornerLayout 16 FAST/BD CORNER FAST'G INSULATION FASTENING PATTERN FM REQ(PATTERN ONLY) SarnafastenerXP (Fastener will Penetrate Deck by Much as 2") Bottom SARNAFIL SARNATHERM POLYISO 2.4 INCH 13.8 SINGLE LOOSE N/A N/A 4X8 N/A N/A N/A N/A Middle SARNAFIL SARNATHERM POLYISO 2.4 INCH 13.8 SINGLE LOOSE N/A N/A 4X8 N/A N/A N/A N/A Top SARNAFIL SARNATHERM ROOFBOARD-H 1�2„ 2.5 SINGLE MECHANICAL SARNAfASTENER XP 71NCH 4X8 6 10 16 1-75 �-SikaPlan Energysmart.60 mil Roof Membrane (Heat Welded) (White) Induction Welded RhinoBond Assembly ������ ������ BASE FLASHING COMPONENTS �natherm RoofBoard-H nically Attached) natherm 20 psi Polyiso Insulation .aid) natherm 20 psi Polyiso Insulation .aid) Wood Deck r--Sarnafil G459 Flashing .60 mil Roof Membrane (Adhered) (White) Sarnacol 2170 Adhesive � � � . Wayne's Roofing, Inc. GATEWAY NORTH BLDG 3 13105 Houston Road 5umner, WA 98390 S�m (253) 863-d455 Sea (206) 575-007B S YST E M D E S C R I PT I 0 N Fcvc (253) 863-8311 Prepared By Rev. Job No. Scale Section Sheet 4-28-16 T.L 16-032 N.T.S. 002 Wayne's Roofing, Inc. 13105 Houston Road Sumner, WA 98390 www.wavnesroofinq.com Hai�[ s Au�n�c. i�c. � .VNNGN,WA PRODUCT DATA • BU�.OING TRUST � �_� r I. i ,- . �� I`. i� � i i_. ,I � _ SARNATHERM° - 20 psi Sarnatherm is a rigid closed cell polyisocyanurate insulation board with fiber reinforced felt facers. Sarnatherm is suitable for use in new construction and re-roofing with Sarnafil� or Sikaplan� membranes. PRODUCT INFORMATION USES Wherever insulation is required within a conventional roof assembly to achieve specified thermal resistance. AREAS OF APPLICATION ■ New Roofs ■ RecoverRoofs ■ Mechanically Fastened Systems ■ Adhered Systems FEATURES / BENEFITS • Manufactured with no CFCs or HCFCs ■ Virtually no GWP (global warming potential) ■ Zero ODP (ozone depletion potential) ■ Compatible with Sarnafil and Sikaplan membranes CODES / APPROVALS ■ ASTM C 1289 Type II, Class 1, Grade 2(20 psi) • UL 1256, 790, 263 ■ FM 4450, 4470 ■ Miami-Dade County ■ State of Florida PRODUCT DATA COMPOSITION ■ Polyisocyanurate Foam Core ■ Fiber Reinforced Felt Facers COLOR Off-White Core with Dark Brown Facer 1/3 O1-26-15 Version pl . PACKAGING ■ 4'x4'(1.2mx1.2m) ■ 4'x8'(1.2mx2.4m) ■ VariousThicknesses STORAGE STORAGE CONDITIONS Factory-applied packaging is intended only for protection during transit. When ' stored outdoors or on the job site, the insulation should be stacked on pallets at least 4 in (102 mm) above ground level and completely covered with a weatherproof covering such as a tarpaulin. The temporary factory-applied packaging should be slit or removed to prevent accumulation of condensation. Refer to PIMA Technical Bulletin 109: Storage and Handling Recommendations for Polyiso Roof Insulation. TECHNICAL DATA TYPICAL PHYSICAL PROPERTIES* Property ASTM Test Method Results Compressive Strength D 1621 20 psi (138 kPa) Dimensional Stability D 2126 < 2% Water Absortion C 209 < 1.5 % Water Vapor Transmission E 96 < 1.5 perm (85.5 ng /(Pa•s•mz)) Flame Spread E 84 (10 min.) 40-60** Smoke Development E 84 (10 min.) 50-170** -100° to 250° F Service Temperature - ' (-73° to 121° C) *Physical properties listed above are presented as typical average values as determined by accepted ASTM test methods and are subject to normal manufacturing variation. **Numerical ratings are not intended to reflect performance under actual fire conditions. Flame spread index of 5 75 and smoke devefopment <_ 450 meet code requirements forfoam lastic roof insulation. Codes exempt foam plastic insuiation when used in FM 4450 or UL 1256. 2.4 INCH R = 13.8 THERMAL DATA LTTR Value* 5.7 8.6 10.3 11.4 14.4 15.0 17.4 20.5 23.6 in 1.0 1.5 1.8 2.0 2.5 2.6 3.0** 3.5** 4.0* * Thickness mm 25 38 46 51 64 66 76 89 102 flute Spanability in mm 2 - 5/8 66.68 4 - 3/8 111.13 4 - 3/8 111.13 4 - 3/8 111.13 4 - 3/8 111.13 4 - 3/8 111.13 4 - 3/8 111.13 4 - 3/8 111.13 4 - 3/8 111.13 *LTTR (long term thermal resistance) values are based on ASTM C 1289. Test samples were third-party selected and tested by an accredited material testing laboratory. The LTTR results were reviewed by FM Global and certified by the PIMA Quality Mark Program. "`*Use multiple layers when the total desired or specified R-value requires an insulation thickness greater than 2.7 in (68.58 mm). Product Data Sheet North America Sarna[herm - 20 psi Insulation 01-26-15, VERSION #1 � � 2�3 BUILDING TRUST � 4 , SYSTEM INFORMATION INSTALLATION Sarnatherm is installed by a Sika Authorized Applicator. Sarnatherm may be installed by mechanical-attachment to the roof deck with Sarnafasteners and Sarnaplates, by attachment with Sarnacol Board Adhesive, or by hot asphalt depending on project requirements and specifications. Roof insulation which has become wet or damaged should be removed and replaced with solid, dry insulation. Contact Sika Corporation — Roofing Technical Department regarding alternative methods of attachment. MAINTENANCE WARRANTY Standard maintenance of roofs should include regular inspection of flashings, drains and termination sealants at least twice a year and after each storm. As a Sika supplied product, Sarnatherm is covered under Sika Corporation warranties. LEGAL NOTES All information provided by Sika Corporation ("Sika") concerning Sika products, including but not limited to, any recommendations and advice relating to the appliwtion and use of Sika products, is given in good faith based on Sika's current ezperience and knowledge of its products when properly stored, handled and applied under normal wnditions in accordance wi[h Sika's instruc[ions. In practice, the diHerences in materials, substrates, storage and handling conditions, actual site conditions and other factors outside of Sika's control are such that Sika assumes no liability for the provision of such infarmation, advice, recommendations or inrtructions related to Its products, nor shall any legal relationship be created by or arise from the provision of such information, advice, recommendations or instructions related to its products. The user of the Sika product(s) mus[ test the produQ(s) for suitability for the intended appliwtion and purpose before proceeding with the full application of the product�s). Sika reserves the right to change the properties af ks products without notice. All sales of Sika produa�s) are subject to its current terms and condRions of sale which are available at usa.samafil.sika.com or by calling 800-451-2504. SIKA CORPORATION — ROOFING Produc[ Da[a Sheet Sarnatherm — 20 psi O1-2645, VERSION #1 3/3 Prior to each use of any Sika p�oduc4 the user must atways read and follow the wamings end i�structions an the product's most current Product Data Shee; product label and Safery Data Sheet which are avaflable online at use.sarnafil.sfka.com or by wlling Sika's Techniwl Servfce Department at 800-451•2504. Noffifng contafned in any Sika matertals �elieves the user of the o6ligation to read and follow the wamings and instruttion tor each Sfka product es set forth in the cunent Produa DaW Shee4 Product label and Safery Data Sheet prior to produtt use. _ Sika warrants this product for one year from date of installation to be free from manufacturing defects and to meet the technical properties on the current Product Data Sheet if used as directed within shelf life. User determines suRability of product for intended use and assumes all risks. Buyer'z sole remedy shall be limited to the purchase price or replacement of product ezclusive of labor or cast of labor. NOOTXER WARRANTIES EXVRESSORIMPLIEDSHALLAPPLYINQAIDINGANYWARRANTYOFMERQiANTABIIffYORFRNFSS FONA PARTIQ1lAR PURPOSE. SIKA SHAII NOT BE W18LE UNDER ANY LEWLTHEORV FOR SPEqALOR CONSEQUEMIAI DAMAGES. SIIfA SHALL NOT BE RESPONSIBLE FORTXE USE OF THIS PRODUR IN A MANNER TO INFRINGE ON ANY PATEM OR ANY OTHER �NTEILELTUAL PROPERTY RIGHTS HEID BY OTHERS. - UNITED STATES 100 Dan Road Canton, MA 02021 800-451-2504(p) 781-828-5365 (f) usa.sarnafil.sika.com webmaster.sarnafilCn�us.sika.com North America Insulation SIKA CANADA INC. 6915 Davand Drive Mississauga, ON L5T iL5 905-795-3177 (p) 905-795-3192 (f) can.sika.com marketine.construction(�ca.sika.com BUILDING TRUST Product Data Sheet Edition: 09/2012 Version no.: 0001 Sarnatherm Roof Board-H Composition: Packaging: Installation: Availability: Sarnatherm Roof Board-H is a IighMreight, high-density polyisocyanurate roof board for new, re-cover and re-roof applications. The coated fiber glass facers provide strong, smooth surfaces suitable for mechanically at- tached or fully adhered membranes. Sarnatherm Roof Board-H is high-density polyisocyanurate with fiber glass- reinforced facers. Sarnatherm Roof Board-H is provided in a 4 ft. x 8 ft. (1.2 m x 2.4 m) board size and in a thickness of 1/2 inch (13 mm). • Lighiweight for easy hoisting, staging and maneuvering • High impact and flexural strength • Improved resistance to foot traffic and normal roof maintenance • Low water absorption • Easy scoring,.cutting and snapping • UL Classified 790 •�M Approved (consult RoofNav for specific assemblies) Sarnatherm Roof Board-H is packaged 96 pieces per bundle. Weight per sheet is 11 Ibs. (4.9 kg). Protect Sarnatherm Roof Board-H from damage and moisture during transportation and storage. Sarnatherm Roof Board-H is installed by a Sika Sarnafil Authorized Ap- plicator by mechanical-attachment to the roof deck with approved fasteners and plates. Attachment with specialized adhesive(s), options dependent on deck type and Sika Sarnafil system to be installed. Maximize board lengths to minimize end joints with end joints staggered. Drive fasteners firmly against and flush with surface of Sarnatherm Roof Board-H. Sarnatherm Roof Board-H is cut by scoring and breaking. Do not install more Sarna- therm Roof Board-H than can be covered with welded Sarnafil membrane in that day. Sarnatherm Roof Board-H is available directly from Sika Sarnafil Authorized Applicators when used within a Sika Sarnafil Roof System. Contact your Sika Sarnafil Regional Office or visit our website for further information. As a Sika Sarnafil supplied accessory, Sarnatherm Roof Board-H is in- cluded in Sika Sarnafil's System Warranty to the Building Owner. Sarnafil � Maintenance: Technical: Technical Data (as manufactured): Sarnatherm Roof Board-H requires no maintenance. Sika Sarnafil provides technical support. Technical staff is available to ad- vise Applicators as to the correct installation methods of Sarnatherm Roof Board-H. o e Test Method Thickness, nominal Width, standard Length, standard Pieces per pallet Weight per sheet (4x8 sheet) Dimensional Stability ASTM D 2126 "R" Value ASTM C 518 Water Absorption, % max ASTM C 209 Compressive Strength, ASTM D1621 • Mold Resistance ASTM D3273 Service Temperature Recycled Content Flame Classification Corporate Office Sika Sarnafil A Division of Sika Corporation 100 Dan Road Canton, MA 02021 Tel.: (781) 828-5400 1-800-451-2504 Fax: (781) 828-5365 Web: usa.sarnafil.sika.com � 13 mm 4' (1220 mm) 8' (2440 mm) 96 11 Ib. <0.5% (linear change 7 days) 2.5 <1 % Volume >100psi Passed (10) 260 F or less >8% FM Approved (consult RoofNav for specific assemblies) UL Classified 790 Email: webmaster.sarnafil@us.sika.com Canada Office Sika Sarnafil A Business Unit of Sika Canada 6820 Davand Drive Mississauga, ON L5T 1J5 Tel.: (905) 670-2222 1-800-268-0479 Fax: (905) 670-5278 Web: can.sika.com Disclaimer: All information provided by Sika Corporation ("Sika') conceming Sika products, including but not limited to, any recommendafions and advice relafing to the application and use of Sika products, is given in good faith based on Sika's current expenence and knowledge of its products when properly stored, handled and applied under normal conditions in accordance with Sika's instructions. In practice, the dilferences in materials, , substrates, storage and handling conditions, actual site conditions and other factors outside of Sika's control are such that Sika assumes no liability for the provision o/such information, advice, recommendations or instrucfions related to ifs products, nor shall any legal relationship be created by or arise irom the provision o/such informa6on, advice, recommendaHons orinstrucfions related to its products. The user o/ the Sika product(s) must test the product(s) for suitability for the intended applicafion and purpose before proceeding with the full applicafion o/ the product(s). Sika reserves the right to change the properties of its products without nofice. All sales oiSika product(s) are sub%ect to its cument terms and conditions of sale which are availa6le at usa.samafiLsika.com or by calling 800-451-2504. Prior to each use of any Sika product, the user must always read and follow the wamings and insfrucNons on the producYs most cunent Technical Data Sheet product label and Material Safety Data Sheet which are availabfe at usa.sama�l.sika.com or by contacting 800-451-2504. Nothing contained in any Sika materials relieves the user of the o61iga6on to read and follow the wamings and inshuction for each Sika product es set forth in fhe current Technical Data Sheet, producf la6el and Material Safety Data Sheet prior to producf use. � . � Product Data Sheet Edition: 5/2007 Version no.: 0004 Sarnafastener - XP � Overview: Sarnafastener-XP is a specially-designed fastener used with Sarnadisc, Sarnadisc-XPN, Sarnarail or Sarnabar to attach the Sarnafil S327 roof � membrane directly to (16 - 24 gauge) steel roof decks, approved structural ' concrete or wood roof decks greater than 15/32 inch and structural con- ! crete decks. Composition: Sarnafastener-XP is made from carbon steel, treated with a corrosion resistant coating to meet the Factory Mutual 4470 criteria for corrosion resistance. Features: Sarnafastener-XP has an enhanced buttress thread to increase both surface.area and friction against the deck for improved backout resistance and exceptionally high pullout values. The shank diameter is approximately 0.21 inch (5.3 mm) and the thread diameter is approximately 0.26 inch (6.6 mm). The driving head has a diameter of approximately 0.435 inch (11 mm) and is #3 Phillips design for positive engagement and simplicity of ap- plication. The thread density is 13 turns/inch (approximately 5 turns/cm). Packaging: Sarnafastener-XP is packaged in boxes or plastic buckets in quantities of 250, 500 or 1000. See Technical Data section for lengths and weights. Installation: For S327 roof inembrane attachment, the Sarnafastener-XP is placed through the Sarnadisc, Sarnadisc-XPN, Sarnarail or Sarnabar, through the membrane, insulation and set into the roof deck with a heavy-duty (4 amp min.), variable speed (0-2500 rpm), reversible screwgun with clutch release and a#3 Phillips drive bit. Sarnafastener-XP must penetrate steel, wooden plank and concrete roof decks 1 inch (25mm) and the underside of plywood roof decks %z inch (13mm). Pre-drill a 7/32" ANSI pilot hole when installing in structural concrete decks using a hammer or rotary hammer drill. Hole shall be 1/2" deeper than required embedment for concrete decks. Care must be taken to not damage the roof deck. Choose the correct fastener length and do not overdrive or underdrive the Sarnafastener-XP. Pullout tests may be required prior to job start. Contact Sika Sarnafil's Technical Department for determination. Availability: Sarnafastener-XP is available directly from Sika Sarnafil Authorized Ap- plicators when used within a Sika Sarnafil roof system. Contact your Sika Sarnafil Regional Office or visit our website for further information. :S Sarnafil � Warranty: Maintenance: Technical: As a Sika Sarnafil-suppiied accessory, Sarnafastener-XP is included in Sika Sarnafil's Standard or System Warranry to the Building Owner. Sarnafastener-XP requires no maintenance. Sika Sarnafil provides technical support. Technical staff is available to ad- vise Applicators as to the correct installation method of Sarnafastener-XP. Technical Data: Lenath Thread Packa4ina Weiaht 1'/ inch 1 inch 1000/Bucket 12 Ib (32 mm) (5.4 kg) 2 inch 1 3/4 inch 1000/Bucket 19 Ib (51 mm) (8.6 kg) 3 inch 2-'/4 inch 1000/Bucket 29 Ib (76 mm) (13.2 kg) 4 inch 2 3/4 inch 1000/Bucket 38 Ib (101 mm) (17.2 kg) 5 inch 3-'/4 inch 1000/Bucket 47 Ib (127 mm) (21.3 kg) 6 inch 3-'/4 inch 500/Bucket 29 Ib (152 mm) (13.1 kg) 7 inch 3-'/4 inch 500/Bucket 33 Ib 178 mm 15.0 k 8 inch 3-'/< inch 500/Bucket 37 Ib (203 mm) � (16.8 kg) '10 inch 3-'/< inch 500/Box 46 Ib (254 mm) . (20.9 kg) "12 inch 3-'/< inch 500/Box 55 Ib (304 mm) (24.9 kg) *14 inch 3-'/ inch 500/Box 65 Ib (356 mm) (29.4 kg) *16 inch 3-3/ inch 250/Box 38 Ib (406 mm) (17.2 kg) Corporate Office Sika Sarnafil Inc. 100 Dan Road Canton, MA 02021 * May be coated with a grey corrosion resistant coating. Canada Office Sika Sarnafil A Business Unit of Sika Canada 6820 Davand Drive Mississauga, ON L5T 1J5 Tel.: (781) 828-5400 Tel.: (905) 670-2222 1-800-451-2504 1-800-268-0479 Fax:(781)828-5365 Fax:(905)670-5278 Web: www.sikacorp.com Emaii: webmaster.sarnafil@us.sika.com Web: www.sika.ca Disclaimer: The information, and, in particular, the recommendation relating to the applicafion and end-use of Sika Sarnafil products, are given in good faith based on Sika Sarnafil's cwrent knowledge and experience of the products when propeAy stored, handled and applied under normal conditions in accordance with Sika Samafil recommendations. In practice, the differences in materials, subsbates and actual site conditions are such that no war- ranty in respect of inerchantability of fiiness for a particular purpose, nor any liability arising out of any legal relationship whatsoever, may 6e infened from this information. The user of the product must determine the producYs suitability for the intended applica6on and purpose. Sika Sarnafil reserves the right to change the properties of its products. The proprietary rights of third parties must be observed. All orders are accepted subject to our current terms of sale and delivery. Users must always refer to the most recenf issue of the local P�oduct Data Sheet for the product concerned, copies o/ which will be supplied on request. � Product Data Sheet Edition: 3/2008 Version no.: 0001 Sarnadisc RhinoBond Overview: Sarnadisc RhinoBond is a specially designed, polymer coated plate used with Sarnafasteners to attach insulation or cover boards directly to the roof deck or structural purlins prior to the installation of the Sika Sarnafil membrane. The membrane will be welded to the Sarnadisc RhinoBond by induction welding. Composition: Sarnadisc RhinoBond is a 3 inch (75 mm) diameter, 0.028 inch (0.7 mm) thick metal plate with a polymer coating, meeting the Factory Mutual 4470 criteria for corrosion resistance. Features: Sarnadisc RhinoBond has a recessed center to provide protection to the membrane underside from abrasion by the fastener head. Packaging: Sarnadisc RhinoBond is packaged in Pails of 500. Each pail weighs ap- proximately 54 Ibs (24 kg). Installation: Sarnadisc RhinoBond is positioned on the surface of the insulation board. A Sarnafastener is set through the center of the disc and set into the roof deck or purlin. The Sarnadisc RhinoBond holds the insulation in piace. Availability: Sarnadisc RhinoBond is available directly from Sika Sarnafil Authorized Applicators when used within a Sika Sarnafil roof system. Contact your Sika Sarnafii Regional Office or visit our website for further information. Warranty: As a Sika Sarnafil supplied accessory, Sarnadisc RhinoBond is included in Sika Sarnafil's Standard or System Warranty to the Building Owner. Sarnafil � ti ♦ Maintenance: Technical: Corporate Office Sika Sarnafil A Division of Sika Corporation 100 Dan Road Canton, MA 02021 Sarnadisc RhinoBond requires no maintenance. Sika Sarnafil provides technical support. Technical staff is available to ad- vise Applicators as to the correct installation method. Canada Office Sika Sarnafil A Business Unit of Sika Canada 6820 Davand Drive Mississauga, ON L5T 1J5 Tel.: (781) 828-5400 Tel.: (905) 670-2222 1-800-451-2504 1-800-268-0479 Fax:(781)828-5365 Fax:(905)670-5278 Web: www.sikacorp.com Email: webmaster.sarnafil@us.sika.com Web: www.sika.ca Disclaimer: The in(ormation, and, in particular, the recommendation relating to the application and end-use of Sike Samafil products, are given in good faith 6ased on Sika Samafil's currenf knowledge and experience of the products when properly stored, handled and applied undernormal condifions in accordance with Sika Samafil recommendations. In practice, fhe dif/erences in materials, substrates and actual site condifions are such that no war- ranty in respect of inerchantabillfy of fitness /or a paRlculai purpose, nor any liabillty aiising out of any legal relationship whatsoever, may be in/ened from fhis information. The user of the product must determine the producYs suitability for the intended applica6on and purpose. Sika Samafil reserves the right to change the properties of its products. The proprietary nghts of third parties must be observed. All orders are accepted subject to our cuRent terms oi sale and delivery. Users musf always refer to the most recent issue of the local Product Data Sheet for the product concemed, copies of which will be supplied on request. . o , - � : � � � ,� � i ' ; ; - "� „ � � � � , ` I ' ;. I t_ � � � . L _- _ '- • BUN.DII� TRUST SIKAPLAN° FASTENED ENERGYSMART ROOF° MEMBRANE ��-��'��, 45 X 60 F E LTBAC K ����rgySmart Sikapian Fastened EnergySmart Roof Membrane is a highly reflective white, nominal thickness PVC membrane with polyester scrim reinforcement offered in nominal 45 mil and 60 mil thicknesses. It is also available in feltback which is manufactured with a recycled felt backing. PRODUCT INFORMATION USES Sikaplan Fastened EnergySmart roof inembrane is mechanically fastened using various attachment components over various substrates. AREAS OF APPLICATION ■ In-seam disc systems ■ In-seam batten, doubie-weld systems ■ RhinoBond� systems ■ New construction and reroofing FEATURES / BENEFITS • Highly dimensionally stable ■ Heat welded seams TESTS STANDARDS / APPROVALS ■ FM Global � ■ Underwriters Laboratories ■ Underwriters Laboratories of Canada ■ California Title 24 ■ U566C LEED ■ �reen Globes Produc[ Data Sheet North America Sikaplan Fastened EnergySmart � Membrane 06-15-15, VERSION i!3 1�4 PRODUCT DATA COMPOSITION Thermoplastic PVC membrane containing ultraviolet light stabilizers, flame retardant and integral reinforcement with a unique lacquer coating on the top surface. COLOR White top surface, dark gray bottom surFace PACKAGING ■ Sikaplan Fastened 45 EnergySmart 10 ft x 150 ft rolls, 420 Ibs per roll, 8 rolls per pallet 5 ft x 150 ft rolls, 210 Ibs per roll, 12 rolis per pallet ■ Sikaplan Fastened 60 EnergySmart 10 ft x 100 ft rolis, 350 Ibs per roll, 8 rolls per pallet 5 ft x 100 ft rolls, 175 Ibs per roll, 12 rolls per pallet ■ Sikaplan Fastened 45 EnergySmart Feltback 10 ft x 100 ft rolls, 344 Ibs p�r roll, 9 rolls per pallet ■ Sikaplan fastened 60 EnergySmart Feltback 10 ft x 100 ft rolls, 403 Ibs per roll, 9 rolls per pallet STORAGE STORAGE CONDITIONS Store rolis on pallets and fully protected from the weather with clean canvas tarpaulins. Unvented polyethylene tarpaulins are not accepted due to the accumulation of moisture beneath the tarpaulin in certain weather conditions that may affect the ease of inembrane weldability. Product Data Sheet North America Sikaplan Fastened Energy5mart Membrane � 06-15-15, VERSION 7t3 � 2/a BUILDING TRUST � TECHNICAL DATA TYPICAL PHYSICAL PROPERTIES"` ASTM ASTM Type III Properties D-4434 Spec. Test Method Requirement Reinforcing Material • -- -- Polyester Overall Thickness, rriil D751 45 45 (nominal) Thickness Over Scrim, mil -- 16 20 Felt Weight, oz/yd2 (feltback membrane only) -- -- 9 Breaking Strength M.D.', Ibf/in. (KN/m) D751 200 (35) 230 (40) Elongation at Break, °/a M. D.' &% C.M.D.1 D751 15 & 15 20 & 20 Seam Strength, %a of originalZ D751 75 Pass Retention of Properties After Heat Aging D3045 -- -- Tensile Strength, %of original D751 90 as Elongation, % of original D751 90 Tearing Resistance, Ibf (N) D751 45 (200) 45 00j Low Temperature Bend, -40°F (-40'C) D2136 Pass P Accelerated Weathering Test G154 5,000 Hours 10,0 0 urs (Florescent Light UV exposure) Cracking (7x magnification) -- None None Discoloration (by observation) -- Negligible egligibl Crazing (7x magnification) -- None None Linear Dimensional Change, % D1204 0.5% max. 0.31 Weight Change After Immersion in Water, % D570 ± 3.0% max. 2.9 Static Puncture Resistance, Ibf (N) D5602 33 (147) Pass Dynamic Puncture Resistance, ft-Ibf (1) D5635 14.7 (20) Pass Recycled Content -- -- 9% Pre-consum� *Results may differ based upon statistical variations depending upon mixing methods and equipment, temper methods, test methods, actual site conditions, and curing conditions. 1 M.D. = Machine Direction, C.M.D. = Cross Machine Direction 2 Failure occurs through membrane rupture not seam failure. Polyester 60 (nominal) 24 9 303 (53) 20 & 20 Pass Pass Pass 45 (200) Pass 10,000 Hours None Negligible None 0.24 2.5 Pass Pass Post-consumer INITIAL SOLAR 3-YEAR SOLAR �NITIAL 3-YEAR INITIAI SOLAR 3-YEAR SOLAR REFLECTANCE REFLECTANCE THERMAL THERMAL REFLECTANCE REFLECTANCE EMITTANCE EMITTANCE INDEX INDEX Sikaplan Fastened 45 EnergySmart White 0.83 0.64* 0.89 Pending 104 Pending Sikaplan Fastened 60 EnergySmart White 0.85 0.66* 0.89 Pending 107 Pending *Derived using the California Title 24 calculation method for aged solar reflectance per Section 110.8(i)2. of the 2013 Building Energy Efficiency Standard, page 102. SYSTEM INFORMATION APPLICATION Sikaplan Fastened EnergySmart Roof Membrane is installed by Sika Corporation Roofing Authorized Applicators. Sikaplan Fastened EnergySmart Roof Membrane is installed on acceptable substrates and fastened to the roof deck using the approved attachment method. The membrane is heat-welded together by trained mechanics using Sika's hot-air welding equipment. Sikaplan Fastened EnergySmart Roof Membrane can be used for flashings on Sikaplan Fastened EnergySmart Roof Membrane roof projects. Product Data Sheet Sikaplan Fastened EnergySmart 06-15-15, VERSION #3 3/4 North America Membrane � BUILDING TRUST � . AVAILABILITY MAINTENANCE WARRANTY From Sika Authorized Applicators when used within Sikaplan roofing systems. Standard maintenance of roofs should include regular inspection of flashings, drains and termination sealants at least twice a year and after each storm. Upon successful completion of the installed roof by the Sika Authorized Applicator, Sika Corporation will provide a warranty to the Building Owner via the Sika Authorized Applicator. LEGAL NOTES All inforrtiation provided 6y Sika Corporation ("Sika") concerning Sika produc[s, including but not limited to, any recommendations and advice , relating to the application and use of Sika produc[s, is given in good faith based on Sika's current experience and knowledge of ks products when properly stored, handled and applied under normal condftions in accordance with Sika's instructions. In practice, the differences in materiais, substrates, storage and handling conditions, ac[ual site conditions and ather factors outside of Sika's cantrol are such that Sika assumes no liability for the provision of such information, advice, recommendations or instructions related to its produc[s, nor shall any legal relationship be created by or arise from the provision of such iniormation, advice, recommendations or inrtructions related to ks products. The user of the Sika product(s) must test the produc[�s) for suitability for the intended application and purpose 6efore proteeding with the full application of the product(s). Sika reserves the right [o change the properties of its products without notice. All sales of Sika product�s) are . subject to its current terms and conditions of sale which are available at usa.sarnafil.sika.com or by cailing 800-051-2504. SIKA CORPORATION — ROOFING Product Data Sheet Sikaplan Fastened EnergySmart 06-15-15, VERSION #3 a/a Prior to each use of any Sika product, the user must always read antl follow the wamings and instruttions on the product's most cunent Vroduct Data Shee4 P�aduct label and Safety DaW Sheet which are available online at usa.sarnafil.sika.com or by wlling Sika's Technical Service Department at B00-451-2504. Nothing contalned in any Sika matertals relieves the user of the obligation to read and follow the wamings antl instruction for each Sika product as set torN in the curtent Product Data Shee; produtt label and Safery Data Sheet prior to product use. Sika warrants this product for one year from date of Installation to be free from manufaRuring defects and [o meet the technical properties on the current Praduct Data Sheet if used as directed within sheN life. User determines suitability of produc[ for intended use and assumes all risks. Buyers sole remedy shall be limited to the purchase price or replacement of produc[ ezclusive of labor or cost of labor. NOOTMER WARRANTIES EXPRESSORIMPLIEDSHALLAPPLYINCLUDINGANYWARRANTYOFMERdiANTABILITYORFRNFSS FORA PARTIQ1lAR VURFOSE. SIKA SHALL NOT BE LIABIE UNDER ANY LEGAL THEORV FOR SPEOALOR CONSEQUENTIAL DAMAGES. SIKA SHALL NOT BE RESPONSIBLE FORTME USE OF THIS PRODUR IN A MANNER TO INFRINGE ON ANY PATENT OR ANY OTHER INTELLECTUAL PROPERTY RIGHTS HELD BY OTXERS. UNITED STATES 100 Dan Road Canton, MA 02021 800-451-2504(p) 781-828-5365 (f) usa.sarnafil.sika.com webmaster.sarnafil(a�us.sika.com North America Membrane SIKA CANADA INC. 6915 Davand Drive Mississauga, ON L5T 1L5 905-795-3177 (p) 905-795-3192 (f) can.sika.com marketin�.construction@ca.sika.com BUILDING TRUST s Product Data Sheet Edition: 11/2013 Version no.: 0009 G459 Flashing Membrane � Overview: G459 flashing membrane is a heat-weldable roofing membrane formulated ; for direct exposure to the weather and is produced with an integral fiber- glass mat reinforcement for dimensional stabiliry. G459 flashing membrane � is used to flash roof penetrations within a Sika Sarnafil roof system. G459 I flashing membrane can be adhered directly to asphalt or other contami- � nated surfaces. ' Composition: G459 flashing membrane is a high quality product containing PVC resin, pigments, stabilizers, ultraviolet absorbers, and a fiberglass carrier sheet. G459 flashing membrane comes in 6.5 ft. x 65 ft. and 3.25 x 65 ft. options and is 60 mil (1.5mm) thick. The standard color i w i e on tan. The tan side of the membrane must be the side exposed o e contamination. Features: G459 flashing membrane's glass reinforcement makes it highly dimension- ally stable which is ideal for adhered flashing applications at walls, termina- tions and penetrations. G459 flashing membrane is resistant to asphalt and many other rooftop contaminates. Sika Sarnafil recommends testing for compatibility. Contact Sika Sarnafil's Corporate or Regional Offices. Codes and Approvals: Sika Sarnafil's Adhered Systems using G410 PVC membranes are clas- sified by Undenrvriters Laboratories, Inc., Underwriters Laboratories of Canada, FM Global, Miami-Dade and Florida Building Code. Sika Sarnafil membranes also meet the material requirements of Internationat building code. Packaging: G459 flashing membrane rolls are provided individually and are sealed for shipping. Individual rolls are 168 Ibs for 6.5 ft. x 65 ft. and 83 Ibs for 325 x 65 ft. Installation: G459 flashing membrane is installed by Sika Sarnafil Authorized Applicators on walls curbs and certain other penetrations using Sika Sarnafil's Sarnacol adhesives. The seams are then heat welded together by trained operators using Sika Sarnafil's hot-air welding equipment. � Availability: G459 flashing membrane is available directly from Sika Sarnafil Authorized �� Applicators. Contact your Sika Sarnafil Regional Office or visit our website for further information. Sarnafil � Warranty: Maintenance: Technical: Technical Data (as manufactured): Parameters Reinforcing Material Overall Thickness, min., inches (mm) Tensile Strength, min., psi (MPa) Elongation at Break, min. As a Sika Sarnafil-supplied accessory, G459 flashing membrane is included in Sika Sarnafil's Standard or System Warranty to the Building Owner. G459 flashing membrane requires no maintenance. Sika Sarnafil provides technical support. Technical staff is available to advise Applicators as to the correct installation methods of G459 flashing membrane. Seam Strength", min., (% of tensile strength) Retention of Properties After HeatAging Tensile Strength, min., (% of original) Elongation, min., (% of original) Tearing Resistance, min., Ibf (N) Low Temperature Bend, -40 °F (-40 °C) Accelerated Weathering Test (Florescent Light, UV exposure) Cracking (7x magnification) Discoloration (by observation) Crazing (7x magnification) Linear Dimensional Change Weight Change After Immersion in Water Static Puncture Resistance, 33 Ibf (15 kg) Dynamic Puncture Resistance, 7.3 ft-Ibf (10 J) " Failure occurs through membrane rupture not seam failure. Corporate Office Sika Sarnafil A Division of Sika Corporation 100 Dan Road Canton, MA 02021 Tel.: (781) 828-5400 1-800-451-2504 Fax:(781)828-5365 Web: usa.sarnafil.sika.com Typical ASTM Physical Test Method Pro4erties D638 D638 D638 D638 D3045 D638 D638 D1004 D2136 G154 D1204 D570 D5602 D5635 Email: webmaster.sarnafil@us.sika.com Fiberglass 0.060 (1.5) 1600 (11.1) 270% M.D. 250% C.M.D. 80 95 90 14 (63.0) Pass Pass None Negligible None 0.02% 2.5% Pass Pass Canada Office Sika Sarnafil A Business Unit of Sika Canada 6915 Davand Drive Mississauga, ON L5T 1 L5 Tel.: (905) 670-2222 1-800-268-0479 Fax:(905)670-5278 Web: can.sika.com Disclaimer: All information provided by Sika Corporation ("Sike') conceming Sika producfs, including but not limited to, any recommenda6ons and advice rela6ng to the applicallon and use of Sika products, is given in good faith based on Sika's current experience and knowledge of its products when properly stored, handled and applied under normal condifions in acc6rdance with Sika's instructions. In pracfice, the differences in materials, substrates, storage and handling conditions, actual site conditions and other factors outside oi Sika's control are such that Sika assumes no lia6ility lor fhe provision of such information, advice, recommendafions or instrucfions related fo its products, nor shall any legal relationship be creafed by or arise from the provision of such informa6on, advice, recommendafions or instructions related to its products. The user of the Sika product(s) must test the product(s) for suitability for the intended application and purpose before proceeding with the /ull application o/ the product(s). Sika reserves the right to change the properties of its products without no6ce. All sales of Sika product(s) are subject to its current terms and condifions o/ sale which are available at usa.samafil.sika.com or by calling 800-451-2504. Prior to each use of any Sika product, the user must always read and follow the wamings and instructions on the producYs most current Product Data Sheet, product label and Safety Data Sheet which are available online at usa.sarnafii.sika.com or by calling Sika's Technical Service Department at 800-451-2504. Nothing contained in any Sika materials relieves the user ofthe obligation to read and followthe wamings and instruction for each Sika product as set forth in the current Product Data Sheet, product label and Safety Data Sheet priorto product use. Sika werrants this product for one year irom date oi installafion to be free from manufactunng defects and to meet the technical properties on the current Product Data Sheet if used as directed within shelf li/e. User determines suitability o(product /or intended use and assumes all risks. Buyer's sole remedy shall be limited to the purchase price or replacement of product exclusive of labor or cost of labor. NO OTHER WARRANTIES EXPRESS OR IMPLIED SHALLAPPLY INCLUDING ANY WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. SIKA SHALL NOT BE LIABLE UNDER ANY LEGAL THEORY FOR SPECIAL OR CONSEQUENTIAL DAMAGES. SIKA SHALL NOT BE RESPONSIBLE FOR THE USE OP THIS PRODUCT IN A MANNER TO INFRINGE ON ANY PATENT OR ANY OTHER INTEL- LECTUAL PROPERTY RIGHTS HELD BY OTHERS. � BtlIl.01NG TRUS�'i � ; ; ,; , � � ; i ,,� � , � � � �� � . , ':�_ ' � � ' � �_ � � � �t� � �� . : � i SA R N ACO L� ��. �O USE AT BASE FLASHING Sarnacol� 2170 membrane adhesive is a solvent-based reactivating adhesive used within a Sarnafil� adhered roofing and waterproofing system. It is also used to adhere flashings in any Sarnafil system. It is formulated for adhering Sarnafil PVC membranes to properly prepared substrates such as wood, sheet steel, masonry, concrete, insulations and approved coverboards. PRODUCT INFORMATION PRODUCT DATA fORM USES Sarnacol 2170 is uniquely formulated to be compatible with Sarnafil membranes. AREAS OF APPLICATION Bareback Membrane Substrates ■ isocyanurate Organic Facer ■ Isocyanurate Glass Facer ■ Smooth Plywood • Metal ■ Concrete Wall ■ DensDeck� • DensDeck Prime° ■ Securock� Gypsum Fiber Feltback Membrane Substrates ■ Isocyanurate Organic Face ■ Isocyanurate Glass Facer ■ Smooth Plywood ■ Metal ■ Concrete Deck ■ Concrete Wall ■ Masonry Wall ■ CellularConcrete ■ DensDeck� ■ OensDeck Prime° ■ Securock� Gypsum Fiber COMPOSITION Liquid COLOR Da rk Yellow INSTRUCTIONS ON THE PRODUGT'S MOST CURRENT PRODUCT DATA SHEET, PRODUCT LABEL AND SAFE7Y DATA SHEET W HICH ARE AVAILABLE ONLINE AT USASARNAFILSII(ACOM OR BV CALUNO SINA SARNAFIL'S TECHNICAL SERVICE DEPARTMENTATlOW5745M.NOTHIN6CONTAINEDIN AHY SII(A MATERIA�S RELIEVES TXE USER OF THE OBUOATION TO READ AND FOLLOW THE WARNIN65 AND INSTRUCTIONS FOR EACH SIIU PRODUCT !S SET FORTN IN THE CURREHT PRODUCT DATA 9HEET, PRODUCT LABEL AND SAFETY DATA SHEET PRIOR TO PRODUCTUSE. 1/4 10-01-14 Version # 1 � STORAGE SYSTEM INFORMATION APPLICATION INSTRUCTIONS VOC CONTENT 694.2 g/I PACKAGING 5 gallon (18.9 L) pails, 45 Ibs (20.4 kg) per pai�, 48 pails per pallet. STORAGE CONDITIONS Store materials in a dry area between -4"F (-20°C) and 86°F (30'C) with careful handling to prevent damage to products. Do not store at high temperatures or in direct sunlight. Keep lids tightly closed when not in use. Protect all materials from freezing and other damage during transit, handling, storage, and installation. SHELF LIFE 12 months if stored properly in original unopened, sealed and undamaged packaging. SURFACE PREPARATION All surfaces must be clean, dry, and free of dirt, grease, oil, or other contaminants or particulates. MIXING Mix well before use. APPLICATION METHOD / TOOLS Bareback: Sarnacol 2170 is roller-applied to both the membrane and the substrate in the following manner: Apply Sarnacol 2170 to the substrate and allow to dry. After the substrate adhesive has dried completely, apply Sarnacol 2170 to the back side of the membrane, and aliow to become tacky (producing strings) when touched with a dry finger. The Sarnacol 2170 on the membrane shall not be permitted to dry completely. The membrane is then placed on the substrate (mating adhesive surfaces). The bonded sheet shall be pressed firmly in place with a minimum 100 Ib (45 kg) steel, membrane roller, by rolling in two directions (vertical flashings are hand-rolled). Feltback: Sarnacol 2170 is roller-appiied to the substrate and allowed to dry completely. A second coat of adhesive is then applied to the substrate. The second coat of adhesive shall not be permitted to dry completely. The membrane is then placed on the substrate while the adhesive is still wet. The bonded sheet shall be pressed firmly in place with a minimum 100 Ib (45 kg) steel, membrane roller, by rolling in two directions. Installation Note: These installation instructions are a condensed version for the product data sheet. Before installing the membrane with Sarnacol 2170, read the complete instructions detailed in the applicator handbook. INSTRUCTIONS ON 7HE PRODUCT'S MOST CURREN7 PRODUCT DATA SHEET, PRODUC7 LABEL AND SAFETY DATA SHEET W HICH ARE AVAILABLE ONLINE AT USA.SARNAf IL.SIKACOM OR BY CALLING SIKA SARNAFIL'S TECHNICAI SERVICE DEPARTMENT AT 800-r57-2500.�NOTHING CONTAINED IN ANY SINA MATERIALS RELIEVES THE USER OF TME OBLIGATION TO READ AND FOLLOW THE WARNINGS AND INSTRUCTIONS FOR EACH SIKA PRODUCT AS SET FORTH IN THE CURREHT PRODUCT DATA SHEET, PRODUCT LABEL AND SAFEfY DATA SHEET PRIOR TO PRODUCTUSE. 2/4 10-01-14 Version # 1 Sarnacol 2170 � BUILDING TRUST COVERAGE Bareback Membrane Substrates Isocyanurate Organic Facer 1-% G/Sq. (0.71 L/MZ) Isocyanurate Glass Facer 1%z G/Sq. (0.61 L/MZ) Smooth Plywood 1%: G/Sq. (0.61 L/MZ) Metal 1-'/< G/Sq. (0.51 L/MZ) Concrete Wall 1% G/Sq. (0.71 L/MZ) Dens-Deck� 1-% G/Sq. (0.71 L/M2) Dens-Deck Prime� 1-'/: G/Sq. (0.61 L/Mz) Securock� Gypsum-Fiber 1%z G/Sq. (0.61 L/MZ) Feltback Membrane Substrates Isocyanurate Organic Facer 2-'/< G/Sq. (0.92 L/MZ) Isocyanurate Glass Facer 2 G/Sq. (0.81 L/MZ) Smooth Plywood 2 G/Sq. (0.81 L/MZ) Metal 1-% G/Sq. (0.71 L/MZ) Concrete Deck 2% G/Sq. (0.92 L/MZ) Concrete Wall 2% G/Sq. (0.92 L/MZ) Masonry Wall 2-'/< G/Sq. (0.92 L/M2) Cellular Concrete 2% G/Sq. (0.92 L/MZ) Dens-Deck� 2-'/< G/Sq. (0.92 L/Mz) Dens-Deck Prime� 2 G/Sq. (0.81 L/MZ) Securock� Gypsum-Fiber 2 G/Sq. (0.81 L/MZ) PRODUCT LIMITATIONS LIMITATIONS: Precautions should be taken to prevent odors and/or vapors from entering the building/structure, including but not limited to turning off and sealing air intake vents or other means of ingress for odors and/or vapors into the building/structure during product application and cure. • Do not apply in wet weather or to a wet surface. • Open time varies depending on weather and temperature conditions. • The open time will be shorter on hot days and longer on cold dry days. PRIOR TO EACH USE OF ANV SIKA PRODUCT, THE USER MUST ALWAYS READ AND FOLLOW THE WARNINGS AND - INSTRUCTIONS ON THE PRODUCT'S MOST CURRENT PRODUCT DATA SHEET, PRODUCT LABEL AND SAFETY OATA SHEET WHICHAREAVAILABLEONLINE ATUSA.SARNAFIL.SIKA.COMORBYCALlIN6SIKASARNAFIL'STECHNICALSERVICE � DEPARTMENT AT 806d51-2504. NOTHINO CONTAINED IN ANY SIKA MATERIALS RELIEVES THE USER OF THE OBLI6ATION TO � READ AND FOLLOW THE WARNINOS AND INSTRUCTIONS FOR EACH SIKA PRODUCT AS SET FORTH IN THE CURRENT CRODUCT DATA SHEET, PRODUCT LABEL AND SAFETY DATA SHEET PRIOR TO PRODLCTUSE. ' � 3/a 10-01-14 version # 1 sarnacol 21�o BUILDING TRUST AVAILABILITY MAINTENANCE WARRANTY • Eliminate uneven surfaces to ensure positive contact between the membrane and the substrate. • Unused adhesive can be saved for use at a later date by simply replacing the pail cover. • From Authorized Applicators when used within Sarnafil or Sikaplan roofing and waterproofing systems. Standard maintenance of roofs, green roofs and plaza decks should include regular inspection of flashings, drains and termination sealants at least twice a year and after each storm. As a Sika supplied accessory, Sarnacol 2170 is covered under Sika Corporation warrantees. LEGAL NOTES All information provided by Sika Corporation ("Sika") concerning Sika products, including but not limited to, any recommendations and advice relating to the appliwtion and use of Sika products, is given in good faith based on Sika's current experience and knawledge of its products when properly stored, handled and applied under normal cond'rtions in accordance . with Sika's instructions. In practice, the diHerences in materials, substrates, storage and handling cond"Rions, actual site wnd'Rions and other tactors outside of Sika's control are such that Sika assumes no liability for the provision of such information, advice, recommendations or instructions related to i[s praduc[s, nor shall any legal relationship be created by or arise from the provision of such information, advice, recommendations or instructions related to its products. The user of the Sika product(s) must test the product�s) for suitability for the intended application and purpose before proceeding with the full appliwtion of the product(s�. Sika reserves the right to change the properties of ks produRs without notice. All sales ot Sika . produc[�s) are subjeQ to its curcent terms and condRions of sale which are available a[ usa.sarnaiil.sika.com or by calling 800- 451-2504. - Prior to eath use of any5ika product, the user must always read and follow tMe wamings and instruaions on the praduct's most cunent Product Data SAeet, produtt label and SaMty Data Sheet which are available online at usa.samafil.sika.com or � by calling Stka's Technical5ervice Depanment at 800-451d504. Nothing contained in any Sika materials relieves the user of the obligation to reed and follow the wamings and Instruction for each Sfka product as set forth in the current Product Data Sheet, product label and Safety Data Sheet prior to produa use. Sika warran[s this product for one year from date of installation to be ftee from manufacturing defec[s and to meet the technical properties on the current Product Data Sheet ii used as direc[ed wi[hin shelf life. User determines suRability of produR for intended use and assumes all risks. Buyer's sole remedy shall be limited to the purchase price or replacement of product exclusive ot labor or cost of labor. NOOTHER WARRAMIES EXVRESSORIMPLIEDSHALLAVPLYINf1UDINGANYWARRAMYOFMER6fAMABILT'ORFRNESS fOR A PARTIL11lAR PURPOSE. SIKA SNALL NOT BE W1BLE UNDER AN`/ IFGAI THEORY FOR SPECIAL OR CONSEQUEMIAL ' DAMAGES. SIKASHALL NOT BE RESPONSIBLE FORTHE USE OF THIS VRODUR IN A MANNER TO INFRINGE ON ANY PATENT OR ANY OTNER IMELLECTUAL VROPERTY RIGHTS MEID BY OTHE0.5. SIKA CORPORATION — ROOFING UNITED STATES SIKA CANADA INC. 100 Dan Road 6915 Davand Drive Canton, MA 02021 Mississauga, ON LST 1L5 800-451-2504(p) 905-795-3177(p) 781-828-5365 (f) 905-795-3192 (f) usa.sarnafil.sika.com can.sika.com webmaster.sarnafilC«�us.sika.com marketin�.constructionC�ca.sika.com INSTRUCTIONS�ON �THE PRODUCT'S MOST CURRENT PRODUCT�DATA SHEET, PRODUCT LABEL AND SAFETV DATA SHEET W HICH ARE AVAILABLE ONLINE AT USA.SARNAFIL.SIKA.COM OR BY CALLINO SINA SARNAFIL'S TECHNICAL SERVICE DEPARTMENT AT 800-057-250Y. NOTHING CONiAINED IN ANY SINA MATERIALS RELIEVES THE USER OF THE OBLIOATION TO READ AND FOLLOW THE WARNIN65 AND INSTRUCTIONS FOR EACH SII(A PRODUCT AS SET FORTH IN THE CURRENT PRODUCT DATA SHEET, PRODUCT LABEL AND SAFEfY DATA SHEET PRIOR TO PRODUCTUSE. 4/4 10-01-14 Version # 1 Sarnacol 2170 BUILDING TRUST � . , , Product Data Sheet � Edition: 2/2013 ! Version no.: 0007 Sarnaclad Overview: Sarnaclad is a heat-weldable flashing product used with Sarnafil G and S membranes to form a monolithic roofing or waterproofing system. Composition: Sarnaclad is a 24 gauge, G90 galvanized metal sheet with a 20 mil (0.5 mm) unsupported Sarnafil membrane laminated on one side. Sarnaclad s lable in seven standard colors. Standard colors are Copper Brown, White Evergreen, Lead Gray, Light Gray, Patina Green, and Tan. Sika Sar- na i s nergy Star rated EnergySmart Rooi� color family consists of White, Tan, Light Gray, and Patina Green. The dimensions of Sarnaclad are 4 ft x 8ft(12mx2.4m)or4ftx 10ft(1.2mx3.Om). Recycled Content (metal): 25% Post Consumer, 6% Pre Consumer Recycled Content (membrane): 0% Features: Sarnaclad is a durable and attractive flashing product capable of being formed into a large variety of shapes and profiles. Heat-welding of Sar- nafil G and S membranes to Sarnaclad assures watertight integrity. The Sarnaclad has a unique lacquer coating to resist staining from airborne dirt and pollutants. Packaging: See Technicai Data section for information. Installation: Sarnaclad is cut to size and formed to shape on standard sheet metal . equipment. Sarnaclad is fastened in position in accordance with Sika Sar- nafil Technical requirements. The Sarnaclad joints are covered by 2 inch (50 mm) wide aluminum foil tape and then made watertight by heat-weld- ing a 4 inch (100 mm) wide G410 membrane strip over the tape. By use of a Sarnafil G or S coverstrip, the roofing or waterproofing membrane is then heat-welded to the Sarnaclad. Availability: Sarnaclad is available directly from Sika Sarnafil Authorized Applicators when used within a Sika Sarnafil roofing or waterproofing system. Contact your Sika Sarnafil Regional Office or visit our website for further informa- tion. Warranty: As a Sika Sarnafil-supplied accessory, Sarnaclad is included in Sika Sarnafil's Standard or System Warranty to the Buiiding Owner. Sarnafil � � Maintenance: Technical Data: � Corporate Office Sika Sarnafil A Division of Sika Corporation 100 Dan Road Canton, MA 02021 Sarnaclad requires no maintenance. Sika Sarnafil provides technical support. Technical staff is available to ad- vise Applicators as to the correct installation method of Sarnaclad. Sheets/Pallet Size WeighUSheet Weight/Pallet 25 4ftx8ft (1.2mx2.4m) 25 4ftx10ft (1.2mx3.Om) 35 Ibs (16 kg) 905 Ibs (410.5 kg) 44 Ibs (20 kg) 1,130 Ibs (512.6 kg) Recycled Content (metal): 25% Post Consumer, 6% Pre Consumer Recycled Content (membrane): 0% Canada Office Sika Sarnafil A Business Unit of Sika Canada 6915 Davand Drive Mississauga, ON L5T 1 L5 Tel.: (781) 828-5400 Tef.: (905) 670-2222 1-800-451-2504 1-800-268-0479 Fax: (781) 828-5365 Fax: (905) 670-5278 Web: usa.sarnafil.sika.com Email: webmaster.sarnafil@us.sika.com Web: can.sika.com Disclaimer: All intoRnation provided by Sika Corporation ('Sika ) conceming Sika products, including but not limited to, any recommenda6ons and advice relafing to the application and use o/ Sika products, is given in good faith based on Sika's current expenence and knowledge of its products when properfy stored, handled and epplied under normal condi6ons in accordance with Sika's instructions. In practice, the differences in materials, substrates, storage and handling conditions, actual site conditions and other factors outside of Sike's confrol are such that Sika assumes no liability for the provision oi such in/ormation, advice, recommendallons or instrucNons related to its products, nor shal! any legal relationship be created by or arise from !he provision of such informafion, advice, recommendafions orinshucfions related to its products. The user of the Sika product(s) must test the product(s) for suitability for the intended applica6on and purpose before proceeding with the full application of the product(s). Sika reserves the right to change the prope�ties ofits products without nofice. All safes of Sika product(s) are subject to its cunent terms and conditions of sale which are available at usa.samafil.sika.com or 6y calling 800-451-2504. Prior to each use of any Sika product, the usermust always read and lollow the wamings and instrucfions on the products most current Technical Data Sheet product label and Material Sa/ety Data Sheet which are available at usa.samafil.sika.com or by contacting 800-451-2504. Nothing contained in any Sika matenals relieves the user of the obliga6on to read and Iollow the wamings and instruction for each Sika product as set foRh in the current Technical Data Sheet, product label and Material Safety Data Sheet prior to product use. Product Data Sheet Edition: 10/2011 Version no.: 0001 Sarnacorners - Inside Composition: Packaging: Installation: Availability: �a„� �., Q. =�; Sarnacorners - Inside are a 60 mil (1.5 mm) thick prefabricated corner used as a time-saving and attractive part of a wall flashing detail. Sarnacorners - Inside come in EnergySmart white. Sarnacorners - Inside are injection molded with the same time-proven for- mulation used in our Sarnafii membranes. Sarnacorners - Inside simplify the flashing procedures for inside corner details reducing the risk of leakage. They are available in one size which accomodates most inside corners. Sarnacorners - Inside are heat-welded in place, becoming an integral part of the flashing assembly. Sarnacorners - Inside are packaged in boxes of 10 pieces. Each box weighs a total of 30 Ibs (13.6 kg). � After the wall flashings are installed, Sarnacorners - Inside are heat welded in place with a hand-held hot-air welder and roller. No cauiking or sealants are necessary. Sarnacorners - Inside are available directly from Sika Sarnafil Authorized Applicators when used within a Sika Sarnafil Roofing or Waterproofing System. As a Sika Sarnafil supplied accessory, Sarnacorners - Inside are included in Sika Sarnafil's Standard or System Warranty. Sarnafil � � Maintenance: Sarnacorners - Inside require no maintenance. Periodic maintenance of a Sika Sarnafil system ensures e�ended performance and reduces life cycle costs. Consistent with industry practices, Sika Sarnafil recommends in- specting the roof system for damage, plugged drains, weathered sealants, etc. at least twice a year and after each storm. Technical: Corporate Office Sika Sarnafil A Division of Sika Corporation 100 Dan Road Canton, MA 02021 Sika Sarnafil provides technical support. Technical staff is available to advise applicators as to the proper installation method. Canada Office Sika Sarnafil A Business Unit of Sika Canada 6820 Davand Drive Mississauga, ON L5T 1J5 Tel.: (781) 828-5400 Tel.: (905) 670-2222 1-800-451-2504 1-800-268-0479 Fax:(781)828-5365 Fax:(905)670-5278 Web: usa.sarnafil.sika.com Email: webmaster.sarnafil@us.sika.com Web: can.sika.com Disclaimer: The infama6on, and, in particular, the recommenda6on relating to the application and end-use o/ Sika Samafil products, are given in good faith based on Sika Samafil's currenf knowledge and experience of the products when properiy stored, handled and applied undernormal condi6ons in accordance with Sika Samafil recommendations. In practice, the differences in materials, substrates and actual site condiHons are such that no war- ranty in respect of inerchantabfltty of �tness for a particular purpose, nor any lfability arising out of any legaf relationship whatsoever, may be infened from thls Information. The user of the product must determine the producYs suitability for the infended applicaHon and purpose. Sika Samafil reserves the right to change the properties of its products. The proprietary rights of third parties must be observed. All orders are accepted subject to our current te�ms of sale and delivery. Users must ahvays re%r to the most recent issue of the local Product Data Sheet for the product concemed, copies of which will6e supplied on request. ' Product Data Sheet Edition: 10/2011 Version no.: 0001 Sarnacorners - Outside Overview: Composition: Sarnacorners - Outside are a 60 mil (1.5 mm) thick prefabricated corner used as a time-saving and attractive part of curb and wall flashing details. Sarnacorners - Outside are available in EnergySmart white. Sarnacorners — Outside are injection molded with the same time-proven formulation used in Samafil membranes. Features: Sarnacorners — Outside simplify the flashing procedures for various penetrations, reducing the risk of leakage at outside corner details. They are available in one size which will accommodate most outside.corners. Sarnacorners - Outside are heat-welded in place, becoming an integral part of the flashing assembly. Packaging: Instailation: Availability: Warranty: Each carton contains 20 outside corners. Each box weighs a total of 30 Ibs {13.6 kg). After the curb or wall flashings are installed, Sarnacorners - Outside -are heat welded in place with a hand-held hot-air welder and roller. No caulking or sealants are necessary. Sarnacorners - Outside are available directly from Sika Sarnafil Authorized Applicators when used within a Sika Sarnafil Roofing or Waterproofing System. As a Sika Sarnafil supplied accessory, Sarnacorners - Outside are included in Sika Sarnafil's Standard or System Warranty. Sarnafil � C ♦ Maintenance: Sarnacorners - Outside require no maintenance. Periodic maintenance of a Sika Sarnafil system ensures extended performance and reduces life cycle costs. Consistent with industry practices, Sika Sarnafil recommends inspecting the roof system for damage, plugged drains, weathered seal- ants, etc. at least twice a year and after each storm. Technical: Corporate Office Sika Sarnafil A Division of Sika Corporation 100 Dan Road Canton, MA 02021 Sika Sarnafil provides technical support. Technical staff is available to advise applicators as to the proper installation method. Canada Office Sika Sarnafii A Business Unit of Sika Canada 6820 Davand Drive Mississauga, ON L5T 1J5 Tel.: (781) 828-5400 Tel.: (905) 670-2222 1-800-451-2504 1-800-268-0479 Fax: (781) 828-5365 Fax: (905) 670-5278 Web: usa.sarnafil.sika.com Email: webmaster.sarnafil@us.sika.com Web: can.sika.com Disclaimer: The inlormation, and, in particulai the recommendation relafing to the application and end-use o/Sika Samafil products, are given in good faith based on Sika Samafil's current knowledge and experience of the products when properly stored, handled and applied undernormal conditions in accordance with Sika Samafil recommendallons. In pracNce, the diHerences in matedals, substrates and actual site conditions are such fhat no war- ranty in respect of inerchantabillty of fitness for a particufar purpose, nor any IlabflNy arising out of any legal relationship whatsoever, may be inferred from this informatfon. The user ol the product must determine the product's suitability /or the intended applica6on and purpose. Sika Samafil reserves the dght to change the properties of its products. The propnetary nghts of third parfies musf be observed. All orders are accepted subject to our current terms of sale and delivery. Users must always refer to the most recent issue of the local Product Data Sheet for the product concemed, copies oi which will be supplied on request. r � . Product Data Sheet Edition: 04/2013 Version no.: 0002 Sarnastack Universal Composition: Packaging: Installation: Availability: Sarnastack Universal is a 60 mil (1.5 mm) thick prefabricated stack/pipe boot used as a time-saving and attractive part of a Sika Sarnafil roofing system. Sarnastack Universal comes in EnergySmart White, Tan and Light Gray. Sarnastack Universal is injection molded with the same time-proven formu- lation used in our Sarnafil membranes. Sarnastack Universal simplifes the flashing procedures for stack/pipe details reducing the risk of leakage. They are available in one size which accomodates stack/pipe penetrations from 3/4" - 8" (19mm-203mm) in diameter. Sarnastack Universal is heat-welded in place, becoming an inte- gral part of the Sika Sarnafil roofing system. Sarnastack Universal is packaged in boxes of 8 pieces and comes with custom made stainless steel clamps. Each box weighs a total of 30 Ibs (13.6 kg). Sarnastack Universal's lower flange is heat welded in place with a hand- held hot-air welder and roller. The top is then clamped to the stack/pipe using the clamp provided. Sikaflex 1a is then used to caulk around the top. Sarnastack Universal is available directly from Sika Sarnafil Authorized Applicators when used within a Sika Sarnafil Roofing or Waterproofing System. As a Sika Sarnafil supplied accessory, Sarnastack Universal is included in Sika Sarnafil's Standard or System Warranty. Sarnafil � Maintenance: Sarnastack Universal requires no maintenance. Periodic maintenance of a Sika Sarnafil system ensures extended pertormance and reduces life cycle ' costs. Consistent with industry practices, Sika Sarnafil recommends in- specting the roof system for damage, plugged drains, weathered sealants, etc. at least twice a year and after each storm. Technical: Corporate Office Sika Sarnafil A Division of Sika Corporation 100 Dan Road Canton, MA 02021 Sika Sarnafil provides technical support. Technical staff is available to advise applicators as to the proper installation method. Canada Office Sika Sarnafil A Business Unit of Sika Canada 6915 Davand Drive Mississauga, ON L5T 1 L5 Tel.: (781) 828-5400 Tel.: (905) 670-2222 1-800-451-2504 1-800-268-0479 Fax: (781) 828-5365 Fax: (905) 670-5278 Web: usa.sarnafil.sika.com Email: webmaster.sarnafil@us.sika.com Web: can.sika.com Disclaimer: All intormation provided by Sika Corporation ("Sika'J conceming Sika products, including but not limited to, any recommendafions and advice rela6ng to the application and use of Sika producfs, is given in good faith based on Sika's current expenence and knowledge of its products when prope�ly stored, handled and applied under normal conditions in accordance with Sika's instructions. In practice, the differences in matenals, substrates, storage and handling conditions, actual site condifions and other factors outside of Sika's control are such that Sika assumes no liability for the provision of such information, advice, recommendations or instructions related to its products, nor shal! any legal relationship be created by or arise from the provision of such in/ormafion, advice, recommendafions orinstrucfions related to its products. The user of the Sika product(s) must test the product(s) for suitabiliry for the intended application and purpose before proceeding with the 1u11 applicafion of the product(s). Sika reserves the right to change the properties ofits products without nofice. All sales of Sika product(s) are subject to its current terms and conditions of sale which are available at usa.samafil.sika.com or by calling 800-451-2504. Prior to each use of any Sika product, the user must always read and follow the wamings and instructions on the product's most current Technical Data Sheet, product label and Material Sa/ety Data Sheet which are available at usa.samafil.sika.com or by contacting 800-451-2504. Nothing contained in any Sika materials relieves the user o/ the obligation to read and lollow the wamings and instruction for each Sika product as set forth in the current Technical Data Sheet, product label and Material Safety Data Sheet prior to product use. �. Product Data Sheet Edition 9.13.2012 Sikaflex-1 a Sikaflex°-1a One part polyurethane, elastomeric sealant/adhesive Ittued lo: Sik� Corparalion Pmduct: Sikatlex�-1A C719:Pass ✓ FxC*35% Comp:-35% Substnte: Mortar, Aluminum, Glass (martN wtStlYe pAneA w(N 9I] RNnu 119J C66L• Hating 40 Validallon Date: 8l�/tz — BN77 No. 0612-511211 convnanrm: � Description Sikaflex-1a is a premium-grade, high-pertormance, moisture-cured, 1-component, polyurethane-based, , non-sag elastomeric sealant. Meets Federal specification TT-S-00230C, Type II, Class A. Meets ASTM , C-920, Type S, Grade NS, Class 35, use T, NT, O, M, G, I; Canadian siandard CAN/CGSB 19.13-M87. Where to Use ■ Designed for all types of joints where maximum depth of sealant will not exceed 1/2 in. ■ Excelient for small joints and fillets, windows, door frames, reglets, flashing, common roofing detail ap- plications, and many construction adhesive applications. ■ Suitable for vertical and horizontal joints; readily placeable at 40°F. ■ Has many applications as an elastic adhesive between materials with dissimilar coefficients of expansion. ■ Submerged conditions, such as canal and reservoirjoints. Advantages ■ Eliminates time, effort, and equipment for mixing, filling cartridges, pre-heating or thawing, and cleaning of equipment. ■ Fast tack-free and final cure times. ■ High elasticity - cures to a tough, durable, flexible consistency with exceptional cut and tear-resistance. ■ Stress relaxation. ■ Excellent adhesion - bonds to most construction materials without a primer. ■ Excellent resistance to aging, weathering. ■ Proven in tough climates around the world. ■ Odorless, non-staining. ■ Jet fuel resistant. ■ Certified to the NSF/ANSI Standard 61 for potabie water. I ■ Urethane-based; suggested by EPAfor radon reduction. ■ Paintable with water-, oil- and rubber-based paints. ■ Capable of t35% joint movement. I Coverage 10.1 fl. oz. cartridge seals 12.4 lineal ft. of 1/2 x 1/4 in. joint. 20 fl. oz. uni-pac sausage seals 24 lineal ft. of 1/2 x 1/4 in. ioint. Packaging Disposable 10.1 fl. oz., moisture-proof composite cartridges, 24/case; and uni-pac sausages, 20 fl. oz., 20/ carton. TypIC81 DBta (Material and curing conditions @ 73°F (23°C) and 50% R.N.) RESULTS MAY DIFFER BASED UPON STATISTICAL VARIATIONS DEPENDING UPON MIXING METHODS AND EOUIPMENT, TEMPERATURE, APPLICATION METHODS, TEST METHODS, AC7UAL SITE CONDITIONS AND CURING CONDITIONS. Shelf Life 10.1 fl. oz. cartridges 12 months 20 fl. oz. uni-pac sausages 12 months 5 gallon pail 6 months 55 gallon drum 6 months Storage Conditions Store at 40°-95°F (4°-35°C). Condition material to 65°-75°F before using. Colors White, coloniai white, aluminum gray, limestone, black, dark bronze, capitol tan, stone and medium bronze. Special architectural colors on request. Application Temperature 40° to 100°F. Sealant should be installed when joint is at mid-range of its anticipated movement. Service Range -40° to 170°F • Curing Rate Tack-free time 3 to 6 hours Tack-free to touch 3 hours Finai cure 4 to 7 days Tear Strength (ASTM D-624) Shore A Hardness (ASTM C-661) Movement Capability (ASTM C-719) Tensile Properties (ASTM D-412) 21 day Tensile Stress Elongation at Break Modulus of Elasticity 55 Ib./in. 21day 40t5 +/- 35% 175 psi (1.21 MPa) 550% 25% 35 psi (0.24 MPa) 50% 60 psi (0.41 MPa) 100% 85 psi (0.59 MPa) Adhesion in Peel (TT S-00230C, ASTM C 794) Substrate Peel Strength Adhesion Loss Concrete 201b. 0% Aluminum 201b. 0% Glass 201b. 0% Weathering ResisWnce Exceilent Chemical Resistance Good resistance to water, diluted acids, and diluted alkalines. Consult Technical Service for specific data. > t ` ' How to Use Linear Feet of Sealant per Gailon Surface Preparation Clean all surfaces. Joint walls must be sound, clean, De th dry, frost-free, and free of oii and grease. Curing . p compound residues and any other foreign matter must Inches Y. yz be thoroughly removed. A roughened surface will also enhance bond. Install bond breaker tape or backer rod �/. 308.0 to prevent bond at base ofjoint. � Priming Priming is not usually necessary. Most substrates only « � 154.0 77.0 require pnming if testing indicates a need or where seal- 'o / 102.7 51.3 � ant will be subjected to water immersion after cure. � i Consult Sikaflex Primer Technical Data Sheet or Techni- � 77.0 38.5 � cal Service for additional information on priming. � Yz 61.6 30.8 I Application Recommended application temperatures: 40°-100°F. , ; For cold weather application, condition units at approxi- �� 51.3 25.7 I mate�y 70°F; remove prior to using. � For best performance, Sikaflex-1a shouid be gunned into joint when joint slot is at mid-point of its designed � expansion and contraction. Place nozzle of gun into bottom of the joint and fill entire joint. Keep the nozzle in the sealant, continue on ; with a steady flow of sealant preceding the noule to avoid air entrapment. Avoid overlapping of sealant to eliminate entrapment of air. Tool sealant to ensure full contact with joint walls and remove air entrapment. Joint dimension should allow for 1/4 inch minimum and 1/2 inch maximum thick- ness for sealant. Proper design is 2:1 width to depth ratio, For use in horizontal joints in traffic areas, the absolute minimum depth of the sealant is 1/2 in. and closed cell backer rod is recommended. � umiiauons ■ . ■ ■ , ■ I ■ ■ ■ ■ , , ■ i ■ ■ I ■ i I ■ ■ I � Caution Handling 8 Storage Hllow 1-WeeK CUfB 8i St8f1Daf0 COn01U0nS WIIB� USIf1g SIkBTIeX-1a In t0t81 w2t2f ImfT12fSI0n SItU8tI0�S 8fld prior to painting. When overcoating with water, oil and rubber based paints, compatibility and adhesion testing is essential. Avoid exposure to high levels of chlorine. (Maximum continuous level is 5 ppm of chlorine.) Maximum depth of sealant must not exceed 1/2 in.; minimum depth is 1/4 in. Maximum expansion and contraction should not exceed 25% of average joint width. Do not cure in the presence of curing silicone sealants. Avoid contact with alcohol and other solvent cleaners during cure. Do not apply when moisture-vapor-transmission condition exists from the substrate as this can cause bubbling within the sealant. Use opened cartridges and uni-pac sausages the same day. When applying sealant, avoid air-entrapment. Since system is moisture-cured, permit sufficient exposure to air. White color tends to yellow slightiy when exposed to ultraviolet rays. Light colors can yellow if exposed to direct gas fired heating element. The ultimate pertormance of Sikaflex-1a depends on good joint design and proper appiication with joint surfaces properly prepared. The depth of sealant in horizontal joints subject to traffic is 1/2 in. Do not tool with detergent or soap solutions. Do not use in contact with bituminous/asohaltic materials WARNING: IRRITANT, SENSITIZER. Contains Polyisocyanate Prepolymer (Mixture), Xylene (CAS 1330-20-7). Causes eye irritation. May cause skin/respiratory irritation. May cause skin and/or respira- tory sensitization after prolonged contact. May be harmfui if swallowed. Reports have associated repeat- ed and prolonged exposure to some of the chemicals in this product with permanent brain, liver, kidney and nervous system damage. Headaches and dizziness may result. Deliberate misuse by inhalation of vapors may be harmful or fatal. Strictly follow all usage, handling and storage instructions. Avoid direct contact. Wear personal protective equipment (chemical resistant goggles/gloves/clothing) to prevent direct contact with skin and eyes. Use only in well ventilated areas. Open doors and windows during use. Use a properly fitted NIOSH respirator if ventilation is poor. Wash thoroughly with soap. and water after use. Remove contaminated clothing and launder before reuse. Store in cool dry well ventilated area. � Cleanup Use personal protective equipment (chemical resistant gloves/goggles/clothing). Without direct contact, � • remove spilled or excess product and placed in suitable sealed wntainer. Dispose of excess product and � container in accordance with applicable environmental regulations. 'i I First Aid Measures Eyes: Hold eyelids apart and flush thoroughly with water for 15 minutes. Skin: Remove contaminated clothing. Wash skin thoroughly for 15 minutes with soap and water. Inhalation: Remove to fresh air. � Ingestion: Do not induce vomiting. Dilute with water. Contact physician. In all cases contact a � physician immedfately if symptoms persist. KEEP CONTAINER TIGHTLY CLOSED • KEEP OUT OF REACH OF CHILDREN • NOT FOR INTERNAL CONSUMPTION • FOR INDUSTRIAL USE ONLY � AI� infortnation provided by Sika Corporation ('Sika") conceming Sika products, inGuding but not Iimited to, any recommendalions and advice relating to lhe i application and use of Sika products, Is given in good fatth based on Sika's curtent experience and knowledge of its products when propeAy stored, handled and applied under nortnal canditions in accordance with Sika's instructions. In practice, the diNerences in materials, subsVates, storage and handling condi- � tions, aclual site conditions and other factors outside of Sika's conlrol are such that Sika assumes no liability for the provision of such information, advice, recommendations or instruclions related to its producls, nor shall any legal relationship be ueated by or arise trom lhe provision of such iniormation, advice, recommendalions or inslructions relaled to its products. The user of the Sika product(s) must test the product(s) fw suitability for lhe infended application and purpose before proceeding wilh the full application of lhe product(s). Sika reserves lhe right to change lhe properties of ils products without notice. . All sales of Sika product(s) are subject to its current terms and conditions of sale which are available at www.s�kausa.com or by caliing 800-933-7452. Prlor to each use of any Sika product, the user must always read and foliow the wamings and instructfons on the produd's most curtent Technica) � Data Sheet, product label and MateHal Safety Data Sheet which are available online at www.slkausa.com or by calling Sika's Technical Service ' Department at 800.933-7462. Nothing contained in any Sika materials relieves the user of the obligation to read and follow the wamings and ., instructfon for each Sika product as set forth in the curtent Technical Data Sheet, product label and Material Safety Data Sheet priorto product use. � LIMITED WARRANTY: Sika warrants this product for one year from date of installation to be free from manufacturing defects and to meet lhe ' technical properties on lhe current Technical Data Sheet if used as directed wfthin shelf life. User delermines suitability of product tor intended use and assumes all risks. Buyer's sole remedy shall be limited to lhe purchase price or replacement of product exGusive of labor or cast of labor. ' NOOTHER WARRANTIES EXPRESS OR IMPLIED SHALLAPPLY INCLUDINGANY WARRANTYOF MERCHANTABIIJTYOR flTNESS FORA PARTICULAR PURPOSESIKASHALLNOTBELIABLEUNDERANYLEGALTHEORYFORSPECIALORCONSEQUENTIALDAMAGES.SIKASHALLNOTBERESPONSIBLE FOR THE USE OF THIS PRODUCTINA MANNERTOINFRINGE ONANY PATENTORANYOTHER IN7ELLECTUAL PROPERTY RIGHTS HELD BYOTHERS. Visit our website at www.sikausa.com 1-800-933-SIKA NATIONWIDE i Regional Iniormation and Sales Centers. For the location oi your nearest Sika sales office, contact your regional center. � Sika Corporation Sika Canada Inc. Sika Mexicana S.A. de C.V. e�� � � 201 Polito Avenue 601 Delmar Avenue Carretera Libre Celaya Km. 6.5 �$� %p� � ; Lyndhurst, NJ 07071 Pointe Claire Fracc, Industrial Balvanera �/ Phone: 800-933-7452 Quebec H9R 4A9 Corce idora, Queretaro � Fax:201-933-6225 Phone:514697-2610 C.P.76920 ���m��^�°x����`� �'.�± � � :D01 �- - • FaX: 5146942792 PhOne: 52 442 2385800 Sika end Sikfaflex are registered trademarks. Fax: 52 442 2250537 p���ed in Canada. a Y '�M ' t � ����ni � � . � :� i 3° � � �, � . . i . _ � �= C / ; l � ' � } � ,,; . _� � . - . SEAM CLEAN ER Seam Cleaner is used during the installation of Sika's roofing and waterproofing membranes in the seam overlap only. It is not to be used as a general membrane cleaner. For general membrane cleaning, please refer to the "localized Membrane Cleaning" technical bulletin #02-13 located at usa.sarnafil.sika.com. PRODUCT INF�RMATION PRODUCT DATA FORM STORAGE TECHNICAL DATA USES Seam Cleaner is used on Sika's PVC roofing and waterproofing membranes in the seam area only. COMPOSITION Colorless liquid VOC CONTENT 0 g/I with exemption; 792 g/I without Acetone exemption ' The U.S. EPA, SCAQMD and others consider the solvent in Seam Cleaner as "exempY', and therefore the producYs VOC content can be considered "0 g/I" and used in all jurisdictions operating under these guidelines. PACKAGING 1 gallon (3.8 L) can, 2 cans per case, 15 Ibs (6.8 kg) per case STORAGE CONDITIONS Store in a cool, dry location at temperatures between 40°F (4'C) and 80°F (27°C). SHELF LIFE 12 months TYPICAL PHYSICAL PROPERTIES* Vapor Pressure: 828 mbar @ SO"C Vapor Density (Air=1): Is heavier than air Specific Gravity: 0.790 Boiling Point: 56°C (133'F) Freezing Point: -95°C (-139'F) pH: S.0 — 6.0 INSTRUCTIONS ON TNE PRODUCT'S MOST CURREM PROOUCT DATA SNEET, PROOUCT LABEL AND SAFETY DAtA SHEET WHICHAREAVAILABLEONLINE ATUSASARNAFILSIKACOMORBYCAWNOSIKASARNAFIL'S7ECHNICALSERVICE DEPARTMENT A7 LOW51-T5M. NOTHING CONTAINED IN ANY SIKA MATERIALS REUEVES THE USER OF THE OBLIOATION TO READ AND FOLLOW THE WARNINOS AND INSTRUCiIONS FOR EACM SIKA PRODUCT AS SET FORTH IN THE CURRENT PRODUCT DATA SHEET, PRODUCT LABEL AND SAFEfY �ATA 9HEET FRIOR TO PRODUCTUSE. 1/2 10-01-14 Version # 1 SYSTEM INFORMATION APPLICATION INSTRUCTIONS PRODUCT LIMITATIONS Viscosity: 0.32 mPa s@ 20°C Evaporation Rate: Not available Color: Colorless "Results may differ based upon statistical variations depending upon mixing methods and equipment, temperature, application methods, test methods, actual site conditions and curing conditions. APPLICATION Open container slowly to relieve pressure. Wearing protective gloves, apply Seam Cleaner to a clean, white cotton rag and rub the wet rag on the area to be cleaned. Follow immediately with a second dry, clean white cotton rag. Heavy concentrations of dirt, dust and residue should be lightly scrubbed off (using a non-scratch scouring pad) the membrane prior to cleaning. Do not pour Seam Cleaner directly on the membrane. COVERAGE Approximately 400 square feet per gallon (9.8 mZ/L). LIMITATIONS Precautions should be taken to prevent odors and/or vapors from entering the building/structure, including but not limited to turning off and sealing air intake vents or other means of ingress for odors and/or vapors into the building/structure during product application and cure. LEGAL NOTES A�I information provided by Sika Corporation ("Sika") concerning Sika products, Induding but not limited ta, any retommendations and advice relating to the application and use of Sika products, is given in good faith based on Sika's current ezperience and knowledge of its products when properly stored, handled and applied under normal conditions In accordance with Sika's instructions. In prec[ice, the differences in materials, su6strates, storage and handling conditions, actual site condi[ions and other factors outside of Sika's control are such that Sika assumes no liability for the provision of such information, advice, recommendations or instnictions related to its productz, nor shall any legal refationship be created by or arise from the provision of such information, advice, recommendations or instructions related to its products. The user of the � Sika product(s) must test the product�s) for suitability for the intended application and purpose before proceeding with the full application of the produR(s). Sika reserves the right to change the properties of Rs products without notice. All sales af Sika produc[�s) are suhject [o its curtent terms and conditions of sale which are available at usa.sarnatil.sika.com or by calling 800- 451-2504. SIKA CORPORATION — ROOFING Prior to each use of any Sike product, the user must always read and follow the wemings and instructions on the product's most turrent Product Data Sheet, product Wbel and Safety DaW Sheet whfch are avaiWble online at use.sarnafil.sfka.com or 6y calling Sika's 7echnical Servtce Department at 800�451-2504. Nothing contained in any Sika materfals relieves the user of the obligation to read and follow the warnings and instruction for each Sfka product as set forth in the current Vroduct Data Sheet, product label and Safety Data Sheet prfor to product use. . Sika warrants this product for one year trom date ot instailation to be free from manufaRuring defeRs and to meet the techniwl properties on the c�rrent Product Data Sheet'rf used as directed within sheH life. User determines sui[ability of product for intended use and assumes all risks. 8uyers sole remedy shall be limited to the purchase price or replacement of produc[ exclusive of labor or cost of labor. NOOTMER WARRANTIES EXPRESSORIMPUEDSHALLAPPLYINQUDINGANYWARRAMYOFMERd1AMABIl1TYORFRNESS FOR A PARTIq1LAR PURPQSE. SIKA SHALL NOT BE LIABLE UNDER ANY LEGAL THEORY FOR SPEqAL OR CONSEQUENTIAL DAMAGES. SIKA SMALL NOT BE RESPONSIBLE FORTHE USE OF THIS PRODUR IN A MANNER TO INFRIfVGE ON ANY VATENT OR ANY OTHER INTEILECfUAL PROPERTY RIGHTS HELD BY OTHERS. UNITED STATES SIKA CANADA INC. 100 Dan Road 6915 Davand Drive Canton, MA 02021 Mississauga, ON L5T 1L5 800-451-2504(p) 905-795-3177(p) 781-828-5365 (f) 905-795-3192 (f) usa.sarnafil.sika.com can.sika.com webmaster.sarnafilCa�us.sika.com marketin�.constructionCc�ca.sika.com INSTRUCTIONS ON THE PRODUCT'S MOST CURRENT PRODUCT DATA SHEET, PRODUCT iABEL AND SAFETV DATA SHEET WHICHAREAVAILABLEONLINE ATUSA.SARNAFILSIKA.COMORBYCALLINGSIKASARNAFIL'STECHNICALSERVICE DEPARTMENT A7 BOPd51•2504. NO7HING CONfAINED IN ANY SIKA MATERIALS RELIEVES THE USER OF iHE OBLIGATION TO READ AND FOLLOW THE WARNINGS AND INSTRUCTIONS FOR EACH SIKA PROOUCT AS SET FORTH IN THE CURRENT PRODUCT DATA SHEET, PRODUCT LABEL AND SAFETY DATA 9HEET PRIOR TO PRODUCTUSE. 2/2 10-01-14 Version # 1 Seam Cleaner 0 BUILDING TRUST r r• . , � Product Data Sheet Edition: 5/2009 Version no.: 0005 I Aluminium Tape � � I Overview: i � Composition: I i � Features: Packaging: Instailation: iAvailability: I I i Warranty: Aluminum Tape is used as a separation barrier between contaminated materi- als and Sarnafil membrane. Aluminum Tape is a 25/50 rated aluminum foil tape with a pressure sensi- tive adhesive applied to one side for bonding to substrates. The adhesive is covered with a paper liner. Aluminum Tape conforms to irregularsurfaces. The paper liner removes easily to expose the pressure sensitive adhesive. Aluminum Tape is available in lengths of 150 ft (�45.7 m) by 2 in (51 mm) wide and comes in rolls of 24 per case. Aluminum Tape is to be applied to a clean, prepared surtace. The surface preparation may include but is not limited to scraping and wiping the surface free of any excessive contaminates. Once the surface has been prepared apply theAluminum Tape to the prepared surface making sure ali contaminated areas are covered completely with the Aluminum Tape. Once the Aluminum Tape is applied, make sure it is securely in place and does not allow any contaminates to be exposed to the contact area of the Sarnafil membrane. Aluminum Tape is available directly from Sika Sarnafil Authorized Applicators when used within a Sika. Sarnafil Roofing or Waterproofing System. Contact Sika Sarnafil or visit our website www.sikacorp.com for further information. As a Sika Sarnafil-supplied accessory, Aluminum Tape is included in Sika Sarnafil's Standard or System Warranty. Sarnafil � �• Maintenance: Technical: Technical Data: Corporate Office Sika Sarnafil A Division of Sika Corporation 100 Dan Road Canton, MA 02021 Aluminum Tape requires no maintenance. Sika Sarnafil provides technical support. Technical staff is available to advise applicators as to the proper installation method. Adhesion to Backing Adhesion to Steel Adhesive Backing Elongation Tensile Break Temperature Range 36 oz./in width (39 N/100 mm) 75 oz./in width (81 N/100 mm) Rubber 2 mil dead soft aluminum foil 11% 23 Ibs/in width (403 N/100 mm) -20°F (-29°C) thru +150°F (66°C) Canada Office Sika Sarnafil A Business Unit of Sika Canada 6820 Davand Drive Mississauga, ON L5T 1J5 Tel.: (781) 828-5400 Tel.: (905) 670-2222 1-800-451-2504 1-800-268-0479 Fax:(781)828-5365 Fax:(905)670-5278 Web: www.sikacorp.com Email: webmaster.sarnafil@us.sika.com Web: www.sika.ca Disclaimer: The information, and, in parficular, the recommendation relating to the application and end-use o/ Sika Sama(1 producfs, are given in good faith based on Sika Samafil's current knowledge and experience of the products when propeAy stored, handled and applied undernormal condifions in accordance with Sika Samafil recommendations. In practice, fhe differences in materials, substrates and actual site conditions ere such that no war- ranty Tn respect of inerchantabflity of �tness for a particular purpose, nor any liabflify aris(ng out of any legal relatlonship whatsoever, may be inferred from this Information. The user of the product must determine the product's suitability for the intended applicaBon and purpose. Sika Samafil reserves the nght to change the properties of its products. The proprietary rights o/ third parties must be observed. All orders are accepted su6ject to our current te�ms oi sale and delivery. Users must afways refer to the mosf recent issue o/ the local Product Data Sheet /or the product concemed, copies of which will be supplied on request. • BlNL�11�16 TRUST ( , i� r � �' ' ' ' i� ' ;`1 � j I' ! ! ' `` _ i ` , � , ; DETAIL MEMBRANE (60 MIL) A heat weldable thermoplastic PVC membrane used in Sarnafil� and Sikaplan� roofing and waterproofing flashing details. Detail Membrane is produced with an integral fiberglass mat reinforcement for dimensional stability and is more pliable than Sarnafil G410 flashing membrane making it easier to stretch and weld. Detail Membrane is intended for flashing pipes, inside/outside corners and unusual shaped penetrations. PRODUCT INFORMATION PRODUCT DATA FORM Produa Data Sheet DETAIL MEMBRANE 02-06-14, VERSION Nl 1�2 USES For Sarnafil and Sikaplan roofing and waterproofing flashing details AREAS OF APPLICATION . • Flashing pipes ■ Inside/outside corners ■ Unusual shaped penetrations FEATURES / BENEFITS ■ More pliable than Sarnafil G410 membrane making it easier to stretch and weld ■ Reinforced for dimensional stability and durability • lacquer coated top surface to reduce dirt pick up ■ Convenient pre-cut rolls COMPOSITION Thermoplastic PVC membrane containing ultraviolet light stabilizers, flame retardant and integral carrier. Detail Membrane has a unique lacquer coating applied to the top surface of the membrane. Available in 60 mil (1.5 mm) thickness. COLORS White, tan or light gray PACKAGING 12" x 50' (30.5 cm x 15.2 m) roll, 20 Ibs (9.1 kg) per roll 24" x 50' (61 cm x 15.2 m) roll, 40 (bs (18.2 kg) per roll North America Flashings . � STORAGE SYSTEM INFORMATION STORAGE CONDITIONS Store rolls standing on end on pallets and fully protected from the weather with clean canvas tarpaulins. Unvented polyethylene tarpaulins are not accepted due to the accumulation of moisture beneath the tarpaulin in certain weather conditions that may affect the ease of inembrane weldability. APPLICATION INSTRUCTIONS Detail Membrane is installed by Authorized Applicators on pipes, corners and other roof penetrations. Detail Membrane can be heated slightly and stretched to conform around various shapes. Seams are heat welded together using standard hot air welding tools. Install Detail Membrane with lacquer coated (glossy appearance) side up. AVAILABILITY MAINTENANCE WARRANTY From Authorized Applicators when used within Sarnafil or Sikaplan roofing and waterproofing systems. Standard maintenance of roofs, green roofs and plaza decks should include regular inspection of flashings, drains and termination sealants at least twice a year and after each storm. As a Sika supplied accessory, Detail Membrane is covered under Sika ` Corporation warranties. LEGAL NOTES All information provided by Sika Corporatian ("Sika") concerning Sika productr, induding but not limited to, any recommendations and advice relating to the application and use of Sika produRs, is given in good faith based on Sika's current � ezperience and knowledge of tts produQs when properly stored, handled and applied under normal conditions in accordance wkh Sika's instruRions. In practice, the differences in materials, substrates, rtorage and handling condRions, actual site condkions and other factors outside of Sika's control are such that Slka assumes no IiabiliTy for the provision of suth infortnation, advice, recommendationz or instruc[ions related to tts products, nor shall any legal relationship be created by or arise from the provision of such information, advice, recommendations or instructions related to its products. The user of the Sika product�s) must test the produtt�s) for suitability for the intended application and purpose before proceeding wi[h the full appliwtion oi the produR�s). Sika reserves the right to change the properties of its produc[s without notice. All sales of Sika . produR�s) are subject to its curcent terms and conditions of sale which are available at usa.sarnatil.sika.com or by calling 800- 451-2504. SIKA CORPORATION — ROOFING Product Data Sheet DETAIL MEMBRANE 02-06-14, VERSION Nl i/z Vrior to each use of any Sfka protluc4 the user must always reed and follow the warnings and instructtons on the producCs most current Product Data Sheet, produ[t label and Safety Data Sheet which are available onllne at usa.sarnaNl.sika.com or by cailfng Sika's Technical Service Depanment at 80405i•2500. Nothing contained (n a�ry Sika materials relieves the user of the obligation to reaA and fallow the wamings and innruction for each Sika product as set forth in the cunent ProduR Data Sheet, product label and Safety Daq Sheet prior to product use. Sika warrants this produc[ for one year fram date of insta�lation to be free fram manufacturing defects and to meet the txhniral properties on the current Produc[ Data Sheet if used as directed wRhin sheH I rfe. User determines suitability of product for intended use and assumes all risks. Buyers sole remedy shall be limited tothe purchase price or replacement of produc[ exclusive of labor or cost of labor. NOOTMER WARRAMIES EXPRESSORIMPIIEDSHALLAPP�YINCLUDINGANYWARRANTYOFMERCHANTABILRYORFRNE55 FOR A PARTIQ1lAR PURPOSE. SIKA SMALL NOT BE IlABIE UNDER ANY LEWL THEORY fOR SPEqAL OR CONSEQUENTIAL DAMAGEt. 511(A SMALLNOT BE RESPONSIBLE FORTHE USE OF THIS PRODUR IN A MANNER TO INFRINGE ON ANY PATEM OR ANY OTHER IMELLERUAL PROPERTY RIGHTS HELD BY OTHERS. UNITED STATES 100 Dan Road Canton, MA 02021 800-451-2504(p) 781-828-5365 (f) usa.sa rnafil.sika.com webmaster.sarnafilC�us.sika.com North America Flashings SIKA CANADA INC. 6915 Davand Drive Mississauga, ON L5T 1L5 905-795-3177(p) 905-795-3192 (f) can.sika.com marketin�.constructionC�ca.sika.com � BUILDING TRUST � Wayne's Roofing, Inc. 13105 Houston Road � Sumner, WA 98390 www.wavnesroofina.com N.f1'tif3 fllMlfllG, 14"f;. � � :UNNGN, N:4 CERTIFICATIONS � t,.tiaR�;, . .�.�-`rt`�'��'. • a � �:.,:�,. , `o: ,-,: ,:� January 5, 2016 Company: Wayne's Roofing, Inc. 13105 Houston Road Sumner, WA 98390 Re Project: Approved Applicator Status To Whom It May Concern: �0�� BUILDING TRUST This letter is to certify that Wayne's Roofing, Inc. is an approved and qualified applicator of Sarnafil roofing systems in good standing. Certified since 2004, Wayne's qualifies for all available roofing warranties offered by Sika Corporation • Roofing. Wayne's Roofing, Inc. has earned the status of Partners Club Elite Applicator, our highest overall rating relative to quality installations, technical expertise, payment history and integrity. If you have any questions, please contact our office. Regards, Kara Sanders Sika Corporation • Roofing SIKA CORPORATION • ROOFING 6590 Darin Way, Cypress, CA 90630 Tel: 714-898-9355 • fax: 714-898-9357 • usa.sarnafil.sika.com See General Information for Roofina Svstems SIKA SARNAFIL INC CANTON COMMERCE CENTER 100 DAN RD CANTON, MA 02021.-2842 USA TGFU.R8992 Roofing Systems Roofing Systems SINGLE PLY MEMBRANE SYSTEMS Class A - Mechanically Fastened 36a. Deck: C-15/32 Incline: Unlimited Paae Bottom R8992 Vapor Barrier (Optional): — Polyethylene or Kraft (not Classified). Insulation (Optional): — One or more layers potyisocyanurate, polystyrene or combinations, any thickness, mechanically fastened or hot mopped. Barrier Board: — Minimum �/a-in. thick Georgia-Pacific Gypsum LLC "DensDeckp Roofboard", "DensDeck Primep Roofboard", "DensDeck DuraGuardTM Roofboard" or minimum'/a-in. thick United States Gypsum Co. "SECUROCK� Glass-Mat Roof Board (Type SGMRX)" or Certainteed Gypsum Inc. "GlasRoc", mechanically fastened with all barrier board butt joints staggered a minimum of 6-in. from plywood deck butt joints, mechanically fastened. Membrane: —"Sikaplan 45", "Sikaplan 60" or "Sikaplan 80", mechanically fastened. For Combustible Roof Decks - Class A: 3. A minimum Yz-in. layer of Sika Sarnafil Inc. "Sarnatherm Roofboard H", or Hunter Panels "H-Shield HD" over a minimum 2.5-in. layer of any Sika Sarnafil Inc. or Hunter Panels Classified polyisocyanurate insulation is placed directly over a combustible roof deck and is covered with any UL Classified roofing membrane used in any UL Class A roofing assembly to achieve a Class A fire Classification. As an alternative, any UL Classified insulation (except expanded or extruded polystyrene), any combination, any thickness, may be used below the 3-in. minimum total thickness. The insulation may be loosely laid or attached with fasteners and plates, hot roofing asphalt or cold adhesive. A vapor barrier (non-UL classified) may also be used below the insulation. All insulation joints must be staggered a minimum of 6-in. from the deck joints or from the insulation joints directly below. The maximum incline shall be in accordance with the Classification established for the membrane/insulation roof covering assembly, however the incline cannot exceed 1/2:12. Wayne's Roofing, Inc. 13105 Houston Road Sumner, WA 98390 www.wavnesroofinq.com uatiti[ s atwritc, i�r.. �� .VMM[M,NO WARRANTI ES 10 Year Warranty Serial No.: SAMPLE � __� �u�7 SIKAPLAN ROOFING WARRANTY FOR COMMERCIAL BUILDI Building Owner: SAMPLE Building Name: SAMPLE Building Address: SAMPLE Applicator: SAMPLE Date of Substantial Completion: SAMPLE e of Inspection: SAMPLE Building/Area Name: SAMPLE � TRUST � nty Telepho SAMPLE Used As: SAMPLE Area Warrante . MPLE sq. ft. Sika Corporation ("Sika"), warrants tothe owner of the buil i ribed above ("Owner"), that subject to t ie conditions, and limita ions, including the limitations set forth in section 10 below, stated herein, Sika Corp will repair roof leaks originating from the Sikaplan Roof g Membrane, Sarnatherm Insulation or Sika Corporation Roofing Acc sories installed accor in ika Corporation's Technical instrudions by a ka Corporation AuthorizedRoofingApplicatorforaperiodoflQ{en�yearscommenc 'hthedateofsubst ompletionoftheinstallationoftheRofingMembrane with no monetary limit with respec[ to roofy�pair costs. TERMS, CONDITIONS, LIMITATIONS Owner shall notify Sika Corporetion n the first busine ay imm ' tely following the di covery of each leak in the Roofing System and confirm in writing within one week. If on Sika Corporetion's inspection Sika Corporation termines that the leak is caused by defect in the Sikaplan Roofing Membrane, Sarnatherm Insulation orAccessory provided b Sika Corporetion to the ' ator for his building orfro a defed in the Sika Corporation Authorized Applicator's workmanship applied to that Sik lan Membrane, except as provi e' he following par raph three (3) Owner's remedies and Sika Corpbration's liability shall be limited to Sika C retion's repair of the Roofing Membrane, Sarnather Insulation or Accessory. This warranty does not apply and may nd void if any of the following occur: (a) The Roofing Membrene, Sarnatherm Insulatio cessory is damaged by a natural disaster i , but not limited to, earthquake, lightning, hail, peak wind gust in ex ale force, hurricane, o do, as defined by The National Weather ' or other acts of God, or: �b) The Roofing Membrane, arnather ation orAccessory is da by any act of negligence, accident, or misu ' cluding, but not limitedto, vandalism, falling obje , civil disobedience, of war, or: (c) A deficient pre-existing ondition or equipment is causi ter entry, or (d) Metal work or other a cessories or equipment is used in the Roo d causes leaks, or: (e) 7hereareanyalterati nsorrepairsmadeonorthroughthecompletedroo, 'ectssuchasbutnotlimi res,equipment,orstructures are placed on or attac to the completed r ' hout first obtaining written aut 'on from Sika Corporation, or: (fl Failure by the Owner or his to use reasonable intaining the roof as described in wner's Guide provided with this warrenty, including that of sealants and caul or: (g) Loss of integrity of the building envelope or structure inclu ' but ' ited to partial or complete oss of roof decking, wall siding, windows, doars or her envelope components m roof damage b ' d blown ' or: (h) Condensation ac mulates ssembly due to rrect design or due reduction m or I (i) Asignificantcha eintheuseofthebuilding ror seeexpectedby5i rporationtoe e installed, or: Q) The Roofing M brane is damaged b contaminates and/or spills, or: (k) Deficient desi applied to the [toofing ch as membrane contact with incompatible materia (I) The Owner fai o comply with every term and c '' n s e�e�� During the period of this ty, Sika Corporation, its agents a loyees, sTiaiYhav access to the r o Should the Roofing Membrane be c led, the cost of exposure of the Membrene for purp iks repair, such as removal and replacement o a ing or overburden, shall be the ' responsibility. �r effectiveness, or: Roofing Membrane as originally and/or substretes, or: during regular business hours. Corporation's investigation and/or 6. Sika Corporation shall have no obligation under this war ntil all invoices for materials, ins ' n, and services provided by Sika Corporetion and the Sika Corporetion Authorized Applicator have been paid for in 7. Sika Corporation's failure at any time to enforce any of the terms or conditi ted herein shall not be nstrued to be a waiver of such provision. 8. This warranty nsferred to a subsequent Owner of the Building if approve ' vance and in riting by Sika Corporation and the cost to process the t nsfer and to inspe a ar oration Roofing System, if necessary, s b t not limited to, removal and replacement of overburden, hall be the Owner's responsibility. 9. The Owner nd Sika Corporetion hereby agreethat any and all claims (contredual, statutory, co w or otherwise), disputes, or suitsthat in any way, dire y or indirectly, arise out of or relate to this Warranty, or the alleged breach thereof, or t any contrects between the owner and Sika Corporati r the alleged breach the design, manufacture, sale, distribution, installa on, and/or inspection of the Sikaplan Roofing System, shall fir submitted to non-bi ' mediation eutral mediatorjointly selected b the parties or, in the absence of agreement, as designated by the Am ' an Arbitration Associa '. In the abse ce of resolution by ' ion, all ch claims shall be settled by arbitration by the American Arbitration Assoa ' n in accordance with t nstru ion IndustryArbitr tion Rules. Anysuch mediation and/orarbitration shalltake place in Boston, Massachusetts. This renty, and any claims, ' tes or suits betw n the parties hereto shall be governed by, and construed and enforced in accordance with, the laws e Commonwealth of Massachusetts. 10. THIS WARRANTY IS GIVEN IN LIEU OF ALL ER WARRANTIES, EXPRE55 OR I PLIED, INCLUDING ANY WARRANTY OF MERCHANTABILITY OR FITNESSFORAPARTICULARPURPOSE.THEREAR WARRANTIESTHATEXTEN BEYONDTHEDESCRIPTIONONTHEFACEHEREOF.THEREMEDIES STATEDHEREINAREEXCLUSIVEREMEDIESANDSIKAC RATIONSNALLNOTBER NSIBLEORLIABIEFORANYINDIRECT,CONSEQUENTIALOR INCID LDAMA6E5 DINGTHEPRESENCEOFMOLD, GI,BACTERIA,SPORES, TOXINSORTHELIKEORFURTHERLOSSOFANYKIND W TSOEVER,INCLUDINGB TNOTLIMITEDTO,DAMAGETOTH LDINGONWHICHTHE OMPONEIYTSOFTHEROOFARESITUATED,DAMAGE T THE CONTENTS THEREO , LOSS OF USE OF rwc a_�i i_�ING OR ANY C ONENT PART T EREOF, OR DAMAGE TO ANY OTHER PROPERTY OR NO REPRESENTATIVE OF 51T(A CORPORATION HAS AUTHORIN TO MAKE Warranty Is Effective SAMPLE Authorized SIKA CORPORATION • ROOfING 100 Dan Road • Canton, MA 02021 Te1:781-828-5400 • Fax: 781•528-5365 • usa.sarnafil.sika.com OR PROMISES EXCEPT AS STATED HEREIN. SAMPLE PLE Date: SAMPLE Roofin Guarante g , Whereas WAYNE'S ROOFING, INCORPORATED, of Sumner, herein called "the Contractor, " has conrpleted applicatioj� orthe fo!lolaving ►•oof � O�vner: SAMPLE WARRANTY Add��ess of Ow�zer.• Type and Name ofBuilding: Locatiorr Area of Roof Date of Completior7: Date Guara�itee Expires: Whereas, at the inception ojsuch work the Contrac�tot�agreed to guar�a`tee`Ihe-aforesaid r bf against faulry materials or workrnanship for a limited period and subject to the coi�ditions herei�i set fortli'�,` � NOW, Therefore, the Contractor {:ereby fiurantees, subje� to the condilions'�re�'n setfordl, 1l�at during a pe�•iod of Two_(_2� year fro�n lhe date of completion said r•oof, it will, ap its oivn cost and e,rpere e, make or cause to be made stech repairs to said roof and composition flashin restrlting solely fi•o»�`faults or defects in mad �ials or- worinna�rslaip applied by or th��ough the Co��tr•actor as may be necessa to mainfai�i said roo in watertig{rt condition. This guarantee is made subject to the following conditions: 1. Specifically excluded from this guarantee is any ana a�l damage to s d roof, the building or contents caused by the acts or omissions of other trades or contractors; l,iShtning, wind �to�rm, ha�lstorm; or other unusual; phenomena of the elements; foundation settlement; failure or cracking d'F the roof deck; def�cts or failure of material used as a roof base over which the roof is applied, faulty construction of �zrapet wall,,copings, chunneys, skylights, vents, supports, or other parts of the building; vapor condensation beneath the�r.Qof; penetra�ions for pitchboxes; or f re. If the roof is damaged by reason of any of fhe foregoing this guarantee shall therei�pon b�come nuil. and void�'o{ the balance of the guarantee period unless such damage is repaired by the Contractor at the ex�j2ense'oi�the party reguesting s`uch repairs. 2. The Contractor is not liable for consequential damages to t e�uilding or contents resulting from any defects in said roof or composition flashing. � ` 3. No work shall be done on said roof, including, but without limttation, work in connection with flues, vents, drains, sign braces, railing, platforms other eQuipment fastened'� or set on th�e taof, and no repairs or alterations shall be made to said roof, unless the Contr� or shall be firsfi�otified, shal�be given the opp�rtunity to make t1�e necessary roofing application recommendations w�th �respect there�o, and such recomme�dations are complied with. Failure to observe this condition shall render this guarantee nu�l, and voi�: -'T.he Contractor- shall .be paid for time and material expended in making recommendations or repairs occasioned�by the work of others on said roof. 4. This guazantee shall become null �rad void if ihe roof is `used-as a promenade or work deck or is sprayed or flooded, unless such use was originally specified an���e specification is noted in paragraph 8 below. Areas that pond water shall not be covered by this guazantee. `. 5. This guara�ntee 'shall-not be or become effec#'ve vnless,and until the Contractor has been paid in full for said roof in accorda ce with the agreement•pursuant to whic�uch roof was applied. 6. This gu tee s'ha3� become null an�void-unless th`8•Contractor is promptly notified of the alleged defect in materials or workmanshi� and providecl an pportunity to uispe'ct^the roof. 7. This guazant�e is in lieu of all�ther guarantees or warranties, express or implied 8. Additional cor�dition's or ex�e'�usions : In Wimess Whereof,�is ins�ment has been duly executed this day of , 2�OX % ` / "� `- � / �� BY � ._ _ WAYNE'S ROOFING, INC. 13105 HOUSTON ROAD SUMNER, VVASHIn'GTON 98390 TAC. (253) 863-4455 : SEA.(2U6) 575d1078 � AUTHORIZED REPRESENTATIVE Donald Guthrie, President City of Tukwila Allan Ekberg, Mayor Department of Community Development Jack Pace, Director May 19, 2016 DAN JOHNSON 13105 HOUSTON RD E SUMNER, WA 98390 RE: Correction Letter # 1 DEVELOPMENT Permit Application Number D16-0121 GATEWAY NORTH - BLDG 3- 3215 S 116 ST Dear DAN JOHNSON, This letter is to inform you of corrections that must be addressed before your development perrfl-iit can be approved. All correction requests from each department must be addressed at the same time and reflected on your drawings. I have enclosed comments from the foilowing departments: BUILDING DEPARTMENT: Allen Johannessen at 206-433-7163 if you have questions r�garding these comments. • (BUILDING REVIEW NOTES) 1. Please indicate R-value for the insulation on the roof. Total R value for commercial building flat roof shall be R- 30. Include manufacturer's installation specifications. (WSEC TABLE C4022) FIRE DEPARTMENT: AI Metzler at 206-971-8718 if you have questions regarding these comments. • The product information allows for mechanicai fastening or hot asphalt. Please indicate which method will be used. Please address the comments above in an itemized format with applicable revised plans, specifications; a�d/or other documentation. The City requires that two 2 sets of revised plan pages, specifications and/or other documentation be resubmitted with the appropriate revision block. In ordet to better expedite your resubmittal, a'Revision Submittal Sheet' must accompany every resubmittal. I have enclosed one for your convenience. Corrections/revisions must be made in person and will not be accepted throu�h the mail or by a messen�er service. If you have any questions, I can be reached at 206-431-3655. Sincerely, Bill Rambo Permit Technician File No. D16-0121 6300 Southcenter Boulevard Suite #100 • Tukwila WashinQton 98188 � Phone 206-431-3670 • Fax 206-431-3hh5 . t�ERMIT COaRD COP�( PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: D16-0121 DATE: 05/20/16 PRO.T,�CT NAME: GATEWAY NORTH — BLDG 3 SITE ADDRESS: 3215 S 116 ST Original Plan Submittal Revision # before Permit Issued X Response to Correction Letter # 1 Revision # after Pennit Issued DEPARTMENTS: P�� � � S ��'�v� �° Building Division � A-t� �/�}' �- �-� b Fire Prevention � Planning Division ❑ Public Warks ❑ Structural � Permit Coordinator �, PRELIMINARY REVIEW: DaTE: 05/24/16 Not Applicable ❑ Structural Review Required ❑ (no approval/revie�� required) REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: DUE DATE: OC�21�16 Approved � Approved with Conditions � Corrections Required ❑ Denied ❑ (corrections entered ir� Reviews) (ie: Zoning Issues) Notation: REVIEWER'S INITIALS: 1�7:r�� Permil Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Stafflnitials: iznsnou PERMIT C40RQ COPY PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: D 16-0121 DATE: 05/10/16 PROJECT NAME: GATEWAY NORTH - BLDG 3 SITE ADDRESS: 3215 S 116 ST X Original Plan Submittal Response to Correction Letter # DEPARTMENTS: � Co,M �Z. �-��� �� Building Division � Revision # Revision # � Covr Z �-1 t--Ib Fire Prevention � before Permit Issued after Permit Issued Planning Division � Public Works � Structural � Permit Coordinator � PRELIMINARY REVIEW: DaTE: OS/12/16 Not Applicable ❑ Structural Review Required � (no approval/review required) REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: DUE DATE: 06�09�16 Approved � Approved with Conditions ❑ Corrections Required � Denied � (corrections e�ztered irz Reviews) (ie: Zoning Issues) Notation: REVIEWER'S INITIALS: DATE: Perrnit Center Use Orrly CORRECTION LETTER MAILED: � � 1 _� Departments issued corrections: Bldg Fire �Q" Ping ❑ PW ❑ Stafflnitials: v 12/18/2013 City of Tukwila Department of Community Development 6300 Southcenter Boulevazd, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206-431-3665 Web site: http://www.ci.tukwila.wa.us Revision submitlals must be submitted in person at the Permft Center. Revisions wiU not be accepted through the mail, fir.� eta Date• .� — Z a-- i �, �❑ ►z� Response to Incomplete Letter # Response to Correction Letter # Plan ChecWPermit Number: D 16�� � 21 1 ❑ Revision #^ after Permit is Issued ❑ Revision requested by a City Building Inspector or Flans Examiner Project Name: Gateway North — Bld� 3 ProjectAddress: 3215 S 116 St RECEIVED CIYV OF iU�CWILA MAY Z Q;���s PE��ti C�i�li�ii Contact Persoa: � 4,,., T c�,� �„� Phone Number: Z- s3 w o�'�� 9 L Summary of Revision: /Z�o %'�� � i .Z�.aJJ I ,. ,-; � > �..J s�-�,H.J� .�� � `/ 6- �/-/� CJ H /� - �V^/� ri L,,�{�ty it ` �'�' a= � O 1 /'"'+_. �.a ^ /' t Z 4�+ i il�. s � /�a= �r+ / � ...�f s / n � � . �o �1,t,>h...� �a.57,� vJ�c.�- j�-`= /".L_ / � My 1/ Q/ v� a F '1+- .,.� /bo F /� �� �,. ��'� ' J � c3 ,( n�J : v c..�= �.•.�-Z� O•�a Jv 5,..-r-��..t j..�� Z Sheet Number(s): "Cloud" or highlight all areas of revision incCuding date nf revisio C Received at the City of Tukwila Permit Center by: �Entered in TRAKiT on J —'/���y pl�cahons�forms-app icabons on line ev�sion submrttal Created: 8-13-2004 RPVICPlI' WAYNE'S ROOFING INC Hume Espanol Contact Safety & Heafth WaShingtori Sta#e Oepartmerit of �abar & i�dustries WAYNE'S ROOFING INC Owner or tradesperson Principals GUTHRIE, DONALD D, PRESIDENT WETHERBEE, RODNEY ALLEN, VICE PRESIDENT JOHNSON, DANIEL JON, VICE PRESIDENT WETHERBEE.KITTY.SECRETARY BULTER, BRIAN LEE, SECRETARY ANDERSON,JEANNE COLETTE,TREASURER WETHERBEE, WAYNE W, PRESIDENT (End: 04/30/2007) MANN, SHARON R, SECRETARY (End: 04/30/2007) Doing business as WAYNE'S ROOFING INC WA UBI No. 600 178 144 License Page 1 of 4 �Search L&I � � a`sS`s�l A-Z.Lidex :Fleli> b4} L,�;.i Claims & Insurance Workplace Rights Trades & Licensing 13105 HOUSTON RD SUMNER, WA 98390 253-863-4455 PIERCE County Business type Corporation Governing persons DONALD GUTHRIE KITTY WETHERBEE; RODNEY WETHERBEE; SHARON MANN; Verify the contractor's active registration / license / certification (depending on trade) and any past violations. Construction Contractor Active. _._ .............._...___ ...._.._......_......,._. Meets current requirements. License specialties GENERAL License no. WAYNESR205Q5 Effective — expiration 11/25/1980— 05/02/2017 Bond THE HANOVER INS CO Bond account no. 1968027 Received by L�I 04/11/2011 $12,000.00 Effective date 04/13/2011 Expiration date https://secure.lni.wa.gov/verify/Detail.aspx?UBI=600178144&LIC=WAYNESR205Q5&SAW= OS/25/2016