HomeMy WebLinkAboutPermit D16-0149 - JOHNSON CONTROLS - OFFICE WALL AND SUSPENDED CEILINGOHNSON COl�TTROLS
3315 S 116 ST
SUITE 115
D 16-0149
City of Tukwila
• Department of Community Development
" • 6300 Southcenter Boulevard, Suite #100
�� Tukwila, Washington 98188
'' ` Phone: 206-431-3670
Inspection Request Line: 206-438-9350
Web site: http://www.TukwilaWA.sov
DEVELOPMENT PERMIT
Parcel No: 0923049068
Address: 3315 S 116TH ST 115
Project Name: JOHNSON CONTROLS
Owner:
Name: EPROPERTY TAX INC DEPT 207
Address: PO BOX 4900 , SCOTTSDALE, WA,
85261
Contact Person:
Name: DAVID KEHLE
Address:
Contractor:
Name:
1913 BONAIR DR SW , SEATTLE, WA,
98116
PRECISION BUILDERS INC
Address: 22531 10TH AVE S, DES MOINES,
WA, 98198
License No: PRECIB1151C2
Lender:
Name: CBRE INC
Address: 20415 72ND AVE S#210 C/0
STOCKBRIDGE CAPITAL GP, KENT, WA,
98032
DESCRIPTION OF WORK:
Permit Number: D16-0149
Issue Date: 6/29/2016
Permit Expires On: 12/26/2016
Phone: (206) 433-8997
Phone: (206) 878-2948
Expiration Date: 1/19/2018
REMOVE INTER�OR NON-BEARING WALLS PER PLAN, INSTALL NEW FULL HEIGHT OFFICE WALL, INSTALL NEW
SUSPENDED CEILING IN NEW AREA, NEW FINISHES
Project Valuation: $9,420.00 Fees Collected: $491.22
Type of Fire Protection: Sprinklers: YES
Fire Alarm:
Type of Construction: IIIB Occupancy per IBC: 6
Electrical Service Provided by: TUKWILA Water District: TUKWILA
Sewer District: VALLEY VIEW
Current Codes adopted by the City of Tukwila:
International Building Code Edition: 2012 National Electrical Code: 2014
International Residential Code Edition: 2012 WA Cities Electrical Code: 2014
International Mechanical Code Edition: 2012 WAC 296-46B: 2014
Uniform Plumbing Code Edition: 2012 WA State Energy Code: 2012
International Fuel Gas Code: 2012
Public Works Activities:
Channelization/Striping:
Curb Cut/Access/Sidewalk:
Fire Loop Hydrant:
Flood Control Zone:
Hauling/Oversize Load:
Land Altering: Volumes: Cut: 0 Fill: 0
Landscape Irrigation:
Sanitary Side Sewer: Number: 0
Sewer Main Extension:
Storm Drainage:
Street Use:
Water Main Extension:
Water Meter: No ` �-?
�� /� // ,� '
Permit Center Authorized Signature;i��!�iL� �/�/✓`-� "( Date: Oj/ ��l
�
I hearby certify that I have read and examined this permit and know the same to be true and correct. All
provisions of law and ordinances governing this work will be complied with, whether specified herein or not.
The granting of this permit does not presume to give authority to violate or cancel the provisions of any other
state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this
development permir,and agree to the conditions attached to this permit.
Signature:
Print Nam
Date:���i -l�C
This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if
the work is suspended or abandoned for a period of 180 days from the last inspection.
PERMIT CONDITIONS:
1: ***BUILDING PERMIT CONDITIONS***
2: Work shall be installed in accordance with the approved construction documents, and any changes made
during construction that are not in accordance with the approved construction documents shall be
resubmitted for approval.
3: All permits, inspection record card and approved construction documents shall be kept at the site of work
and shall be open to inspection by the Building Inspector until final inspection approval is granted.
4: New suspended ceiling grid and light fixture installations shall meet the seismic design requirements for
nonstructural components. ASCE 7, Chapter 13.
5: Partition walls shall not be tied to a suspended ceiling grid. All partitions greater than 6 feet in height shall
be laterially braced to the building structure. Such bracing shall be independent of any ceiling splay
bracing.
6: All construction shall be done in conformance with the Washington State Building Code and the
Washington State Energy Code.
7: There shall be no occupancy of a building until final inspection has been completed and approved by
Tukwila building inspector. No exception.
8: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap
the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks,
wells, and other excavations. Final inspection approval will be determined by the building inspector based
on satisfactory completion of this requirement.
9: Every occupied space other than enclosed parking garages and buildings used for repair of automobiles
shall be ventilated in accordance with the applicable provisions of the International Mechanical Code.
10: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the
City of Tukwila Building Department (206-431-3670).
11: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila
Permit Center.
12: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an
approval of, any violation of any of the provisions of the building code or of any other ordinances of the City
of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other
ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction
documents and other data shall not prevent the Building Official from requiring the correction of errors in
the construction documents and other data.
13: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila
Permit Center (206/431-3670).
17: The total number of fire extinguishers required for a light hazard occupancy with Class A fire hazards is
calculated at one extinguisher for each 3,000 sq. ft. of area. The extinguisher(s) should be of the "all
purpose" (2A, 10 B:C) dry chemical type. The travel distance to any extinguisher must be 75' or less. (IFC
906.3) (NFPA 10, 5.4)
18: The total number of fire extinguishers required for an ordinary hazard occupancy with Class A fire hazards is
calculated at one extinguisher for each 1,500 sq. ft. of area. The extinguisher(s) should be of the "All
Purpose" (3A, 40B:C) dry chemical type. Travel distance to any fire extinguisher must be 75' or less. (IFC
906.3) (NFPA 10, 5.4)
14: Portable fire extinguishers, not housed in cabinets, shall be installed on the hangers or brackets supplied.
Hangers or brackets shall be securely anchored to the mounting surface in accordance with the
manufacturer's installation instructions. Portable fire extinguishers having a gross weight not exceeding 40
pounds (18 kg) shall be installed so that its top is not more than 5 feet (1524 mm) above the floor. Hand-
held portable fire extinguishers having a gross weight exceeding 40 pounds (18 kg) shall be installed so that
its top is not more than 3.5 feet (1067 mm) above the floor. The clearance between the floor and the
bottom of the installed hand-held extinguishers shall not be less than 4 inches (102 mm). (IFC 906.7 and IFC
906.9)
15: Extinguishers shall be located in conspicuous locations where they will be readily accessible and
immediately available for use. These locations shall be along normal paths of travei, unless the fire code
official determines that the hazard posed indicates the need for placement away from normal paths of
travel. (�FC 906.5)
16: Fire extinguishers require monthly and yearly inspections. They must have a tag or label securely attached
that indicates the month and year that the inspection was performed and shall identify the company or
person performing the service. Every six years stored pressure extinguishers shall be emptied and
subjected to the applicable recharge procedures. If the required monthly and yearly inspections of the fire
extinguisher(s) are not accomplished or the inspection tag is not completed, a reputable fire extinguisher
service company will be required to conduct these required surveys. (NFPA 10, 7.2, 7.3)
19: Maintain fire extinguisher coverage throughout.
20: Egress doors shall be readily openable from the egress side without the use of a key or special knowledge
or effort. (IFC 1008.1.8.3 subsection 2.2)
21: Dead bolts are not allowed on auxiliary exit doors unless the dead bolt is automatically retracted when the
door handle is engaged from inside the tenant space. (IFC Chapter 10)
22: Exit hardware and marking shall meet the requirements of the International Fire Code. (IFC Chapter 10)
23: Door handles, pulls, latches, locks and other operating devices on doors required to be accessible by
Chapter 11 of the International Building Code shall not require tight grasping, tight pinching or twisting of
the wrist to operate. (IFC 1008.1.9.1)
24: Aisles and aisle access ways serving as a portion of the exit access in the means of egress system shall
comply with the requirements of this section. Aisles or aisle access ways shall be provided from all
occupied portions of the exit access which contain seats, tables, furnishings, displays and similar fixtures or
equipment. The required width of aisles shall be unobstructed. (IFC 1017.1)
28: Fire protection systems shall be maintained in accordance with the original installation standards for that
system. Required systems shall be extended, altered or augmented as necessary to maintain and continue
protection whenever the building is altered, remodeled or added to. Alterations to fire protection systems
shall be done in accordance with applicable standards. (IFC 901.4)
26: Sprinklers shall be installed under fixed obstructions over 4 feet (1.2 m) wide. (NFPA 13-8.6.5.3.3)
25: All new sprinkier systems and all modifications to existing sprinkler systems shall have fire department
review and approval of drawings prior to installation or modification. New sprinkler systems and all
modifications to sprinkler systems involving more than 50 heads shall have the written approval of Factory
Mutual or any fire protection engineer licensed by the State of Washington and approved by the Fire
Marshal prior to submittal to the Tukwila Fire Prevention Bureau. No sprinkler work shall commence
without approved drawings. (City Ordinance No. 2436).
30: Maintain fire alarm system audible/visual notification. Addition/relocation of walls or partitions may
require relocation and/or addition of audible/visual notification devices. (City Ordinance #2437)
29: All new fire alarm systems or modifications to existing systems shall have the written approval of The
Tukwila Fire Prevention Bureau. No work shall commence until a fire department permit has been
obtained. (City Ordinance #2437) (IFC 901.2)
31: The maximum flame spread class of finish materials used on interior walls and ceilings shall not exceed that
set forth in Table No. 803.9 of the International Building Code.
32: In order to provide you with the fastest police and fire protection under emergency conditions, please post
your suite, room or apartment number in a conspicuous place near the main entry door.
27: Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (City Ordinances
#2436 and #2437)
33: Any overlooked hazardous condition and/or violation of the adopted Fire or Building Codes does not imply
approval of such condition or violation.
34: These plans were reviewed by Inspector 511. If you have any questions, please call Tukwila Fire Prevention
Bureauat(206)575-4407.
PERMIT INSPECTIONS REQUIRED
Permit Inspection Line: (206) 438-9350
1700 BUILDING FINAL**
1400 FIRE fINAL
0409 FRAMING
0606 GLAZING
0502 LATH & GYPSUM
0406 SUSPENDED CEILING
0601 WALL INSULATION
;�J�.N ILA,jy4�
.k,' yZ�
�Q� �-�,;
� 'p,
y�, 2
�290& ,,, ,
CITY OF TUKWILA
Commi�nity Development Department
Public Works Department
Permit Center
6300 Southcenter• Bh=d., Suite 1 QO
Tukwila, WA 98188
�'��--��.�ti�a�.I�uhti��ila1'�� \�`��>�
SITE LOCATION
Building Permit No. ��Q�' 0
Project No.
Date Application Accepted: �p'� C'( � � �Q _
Date Application Expires: _��-����
use
CONSTRUCTION PERMIT APPLICATION
Applications and plans must be comptete in order to be accepted for plan review:
Applications will not be accepted through the mail or by fax.
**Please Print**
� King Co Assessor's Tax No.: �23i� -�Qg� (�
Site Address: ��'� � Suite Number:�� Floor:�
Tenant Name: � ��! New Tenant: �:....Yes ❑ ..No
GENERAL CONTRACTOR INFORMATION
Company Name:
Address:
City: State: Zip:
Phone: Fax:
Contr Reg No.: Exp Date:
Tukwila Business License No.:
H�.\ApplicationslForrts-Appliwtions On Line�2011 Applications\Permil Application Revised � 8-9-11_docs
Recised: Aueust 201 I
bh
ENGINEER OF RECORD
Company Name: �
Engineer Name:
Address:
City: State: Zip:
Phone: Fax:
Email:
LENDER/BOND 1SSUED (required for projects $5,004 or
greater per RCW 19.27.095)
Name: � p.� i11�,/7
�y v�
Address:
City: State: Zip:
Page 1 of 4
BUILDING PERMIT INFORMATION — 206-431-3670
Valuation of Project (contractor's bid price):
Existing Building Valuation: $ �i
Describe the scope of work (please provide detailed information):
�tc�.: Iµ�,�Q2� � �6F���u�- �, �� ,= - iws�u, ta,�w ; � �}r�aHfi
G�G�=�Y6U.1 4W�'i'bu.., i�l�d �� �l�lµc� . �u �Y �¢+E�. � �1C�Y�h1��
Will there be new rack storage? ❑.....Yes � No If yes, a separate permit and plan submittal will be required.
Provide All Building Areas in Square Footage Below
Addition to Type of Type of
Existing Construction per Occupancy per
Existin Interior Remodel Structure New� IBC IBC
151 Fioor �1�T � :/�f �' r' 1�1 '� Y
2" Floor
3` Floor
Floors thtu
Basement
Accessory Structure�`
Attached Garage
Detached Garage
Attached Carport ,
Detached Carport
Covered Deck
Uncovered Deck
PLANMNG DIVISION:
Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches)
*For an Accessory dwelling, pr vide the following:
Lot Area (sq ft): �6 ��+�K Floor area ofprincipal dwelling: Floor area of accessory dwelling:
*Provide documentation that shows that the principal owner lives in one of the d4vellings as his or her primary residence.
Number of Parking Stalls Provided: Standard: T'I� ���i}�i Compact: Handicap:
Will there be a change in use? ❑....... Yes j�....... No If "yes", explain:
FIRE PROTECTION/HAZARDOUS MATERIALS:
...... Sprinklers ❑....... Automatic Fire Alarm ❑.......None ❑. Other s eci
..... � P fY)
Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑....... Yes �......No
If "yes', attach list ofmaterials and storage locations on a separate 8-1/2" r 11 "paper includrng quantities and Mqterial Safery Data Sheets.
SEPTIC SYSTEM
❑....... On-site Septic System — For on-site septic system, provide 2 wpies of a current septic design approved by King County Health
Department.
-_ �-c:icz�.wnvlFor�-Applications On Line12011 ApplicationslPernvt Application Revised- 8A-1l.doc�
+�:+�- .4vgust 2011
�:
Page 2 of -1
PERMIT APPLICATION NOTES —
Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject
to possible revision by the Permit Center to comply with current fee schedules.
Expiration of Plan Review —Applications for which no permit is issued within 180 days following the date of application shall expire by limitation.
The Building Official niay grant one or more extensions of time for additiona! periods not exceeding 90 days each. The extension shall be
requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition).
I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER
PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT.
BUILDING OW R OR A O]ZED AGENT:
Signature: Date: � �a
Print Name: b � Day Telephone: KJfO- �33' U'ta �'
Mailing Address:'-` �� LV�ib�l�• !1G %W � �6 � `� (p
C�ty $tate Zip
H:WpplicntionsVForns-Applita�ions On Line\2011 Applicalio�s\Pemtii Application Rerised - 8-9-1 ].doc�
xe�,s�a: augusi zoi � Paee 4 oF 4
bh �
Date Paid: Wednesday, June 29, 2016
Paid By: PRECISION BUILDERS INC
Pay Method: CHECK 11420
Printed: Wednesday, June 29, 2016 12:53 PM 1 of 1 ��m�t'"�SY57EM5
Date Paid: Thursday, June 09, 2016
Paid By: DAVID KEHLE
Pay Method: CREDIT CARD 02095D
Printed: Thursday, June 09, 2016 8:53 AM 1 of 1 ����
SYS7EM5
�
INSPECTION RECORD
� Retain a copy with permit �� s���9
INSPECTION N0. PERMIT N0.
CITY OF TUKWILA BUILDING DIVISION
6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670
Permit Inspection Request Line (206) 438-9350
8 �� � I �
� REIPISPECTION FEE REQUIRED. Prior to next inspection, fee must be
paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection.
INSPECTIOiV RE
Retain a copy with
INSP ON N0.
�o�p ��..
permit �� �� f y g
PERMIT NQ.
CiTY OE TUKWIL.A BUILDINCi D�VISiON
6300 Southcenter Blvd., #100, Tukwila. WA 98188 (200) 431•3670
Permit Inspection Request Line (206) 438-9350
� Approved per appiicable codes. � Corrections required prior to approvaf.
COMMENTS:
pector:
� RElNSPECTION FEE REQUlRED. Prior to next inspection, fee must be
paid at 6300 5authcenter Blvd.. Suite 100. Call to schedule reinspec#ion.
� IR1SF'��TI�!!4 RECORD ; �
�
� :RPtair� a copy vvith permit ���� � ��y�
I CTION N0. PERMI? P:Q.
CtTY tJ� TU��lL/! SUILDIlVC ���ISlO�
5300 5outhcenter B(vd., #�1.OU, i`ukwifa: WA 98388 (206) 431-367�
Permit Inspectior? Request Line (206} 438-9350
� ��
� Approved per applicabte codes.
nspection:
�� �Date Want��2/ J>G
f
2u,�/
i -- �
� � ' 'T9'G / S30
� Correttions required prior to �approvaf.
� RElNSPECTION FEE REQUIRED. Prior to next inspection, fee musi ae
paid at 6300 Southcenter Blvd., Suite 100. Call to schedule r�inspecficn.
' INSPECTION RECORD �
� Retain a copy with permit ��� �� �y �
INSPECTION N0. PERMIT N0.
CITY OF TUKWILA BUILDING DIVISION
6300 Southcenter Bivd., #100, Tukwila: WA 98188 (206) 431-3670
Permit Inspection Request Line (206) 438-9350
�Approved per applicab�e codes. a Gorrections required prior to approval.
�*�+
U paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection.
INSPECTION RECORD � � , �yg �'�
� Retain a copy with permit � �
INSPECTION N0. PERMIT N0.
CITY OF TUKWILA BUILDING DIVISION
6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670
Permit Inspection Request Line (206) 438-9350
� Appr�oved per applicable codes. � Gorrections required prior to approval.
� REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be
paid at 6300 Southcenter Blvd.. Suite 100. Call to schedute reinspection.
INSPECTION RECORD ��� i1-- �� I',' 1
^ Retain a copy with permit
r_�
INSPECTION NUMBER PERMIT NUMBERS
CITY OF TUKWILA FIRE DEPARTMENT
206-575-4407
Project: Type of Inspection:,t
�
� ��
~ �`,t�� p rt.� ���•1/ � �'' � ! r - r ; �.J � `�
Address: � 31 5-- ��/ b�-�- Contact Person: '
Suite #: , , �
Special In`st`ructions: Phone No.:
�>
Approved per applicable codes. � Corrections required prior to approval.
� �
COMMENTS:
� i. � 4 c�� t_ -- C� %
,
r---. (� ,
� — �', ri� (�l-!C" .4 ., ,
Needs Shift Inspection: Sprinklers:
Fire Alarm: Hood & Duct:
Monitor: Pre-Fire:
Permits: Occupanc T e:
Inspector:
Date:
H rs..
�$100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from
the City of Tukwila Finance Department. Call to schedule a reinspection.
Word/Inspection Record Form.Doc 3/14/14 T.F.D. Form F.P. 113
INSPECTION RECORD /�/� - C�� y`�
Retain a copy with permit
/� - S - /`�6
INSPECTION NUMBER PERMIT NUMBERS
CITY OF TUKWILA FIRE DEPARTMENT �
206-575-4407
Project: � Type of Inspection• . a�
. 0 so �J C��a I S {� �,,�v+�-L
Address: ��� � ,� / j � `�' Contact Person: '
Suite #:
Special Instructions: Phone No.:
�-Approved per applicable codes. � Corrections required prior to approval.
COMMENTS:
P C'p v� -- o �-
S� ��v�� - C��G.
Needs Shift Inspection: Sprinklers:
Fire Alarm: Hood & Duct:
Monitor: Pre-Fire:
Permits: Occu anc T e:
Inspector:
�Z
Date: "]� j�'� � j� Hrs.:
�$100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from
the City of Tukwila Finance Department. Call to schedule a reinspection.
Billing Address
Attn :
Address:
Companv Name:
State:
Word/Inspection Record Form.Doc 3/14/14 T.F.D. Form F.P. 113
�
r •. 2012 Washington State Energy Code Compliance Forms for Commercial, Group R1, and > 3 story R2 and R3
• • • .
2012 Washington State Energy Code Compiian Forms for Commercial, Group R1, and > 3 story R2 and R3 Revised June 2oi3
Project Info Project Address �� 1G�a , Date � a f�
For
Address:
Use
Project Description (❑ New Building ❑ Addition � Aiteration ❑ Plans Included
Lighting Compliance � Lighting Power Density Calculations O Total Building PerfoRnance
Path (!f Total Building Pe►formance then only LGT-CHK is requi►ed.)
Interior Lighting
Compliance Option
Interior Lighting System
Description
describe lighting
i type and features.
� Building Area Method
x
x2
(�. Space-by-space Method
Addiiions and Change of Space Use {C101.4.3 & C101.4.4)
� Addition area or Change of Space Use area complies with all applicabie provisions as stand alone pn
� Addition area or Change of Space Use area is combined with e�sting building lighting systems to der
compliance with all applicable provisions
Provide Building Area Method (LTG-lNT-BLD) or Space-By-Space Mefhod (LTG-INT-SPACE) Comp
allowed arrd proposed (inGuding exis6ng if appticable) lightirrg waftage of Addition or Change of Use
conGrols per C405.2 and commissioning of lighting con6als per C405.13.
Renovations and
REVI�WEt� �'�
'�i0�� �i�M1��.1/"!,.
APPROVED
�
�i af `�ukwifa
❑ 60% or more of luminaires in space reptaced
Provide Building Area Method (LTGINT-BLD) or Space-Sy-Space Meriwd (LTG-lNT-SPACE) Compliance Fomr. Documeni maximum
allowed and proposed (ir�cluding existirrg) IighSng waftage of project scope
�' Less than 60% of laminaires in space replaced
P�ovide Space-by-space Method (LTGINT-SPACE) Compliance Form. Document existing total wattage in space and pro�sed
(including existirtg) lightir►g wattage of prnject scope
❑ Lamp and/or ballast replacement within existing luminaires only — existing total interior building wattage not increased
❑ New wiring installed to senre added fuctures a�d/or fixtures relocated to new circuii
P►rrvide applicable manual ligh6ng controls (C405.2.1), occupancy sensors (C405.2.22), daylight zone conWls (C405.2.2.3), specfic
application controls (C405.2.3), and commissioning of lighSng controls per C405.13
❑ New or moved Iighting panel
Provide all applicable lighting controls as noted for New Wiring, automatic time switch controls {C405.2.2.1), and commissioning of
lighting con6nts per C405.13.
� Space is reconfigured - luminaires unchanged or moved onty
Piovide all applicable lighting controls as noted fnr New �ring and commissioning of lighting contruls per C405.13.
❑ No changes are being made to the inte►ior lighting and space use not changed.
CITY O� T'UKWILA
JUN 0 9 2016
PERMIT CENTER
`�
• -• 2012 Washington State Energy Code
• • • .
2012 Washington State Energy Code Compliance F c fnr r.
Project Info P�O1ect Address OHi�
Maximum Allowed Lighting Wattage
Location (plan #,
room #, or ALL} Space Type"
Forms for Commercial, Group R1, and > 3 story R2 and R3
� • . � �
•- "" -�d > 3 story R2 and R3 Revised June 2013
�, � Date �
�`) y ° For Building Department Use
Atrimn;i Snter Height:
Retail Display Allomance from LGT-INT-DISPLAY
' Select Table C405.5.2(2) category from drop down menu.
" For at►iums, indicate height.Allowed wattage for first 40 feet is 0. 03 W/R. ht ,
above 40 ieet is 0.02 W/R. ht.
Proposed Li hting Watta e
Location (plan #, Fixture Description
room #, or ALL) (Include exempt equipment per Note 3)
�1 uEu 6�tc� Zx� X 3 U�
� ( Area in ft� �(wattslft x area)
1.. � I
Area Allowed Watts
Total �?�„� �g
Number of I Watts/ I Watts
Fixtures Fature P�oposed
Retail Display Liqhting from LGT-INT-DISPLAY
__ _
Tofa! Proposed Watts may not exceed Total Allowed Watts for Interior Lighting Total Proposed Watts ��j%j
Notes:
1. For proposed Fixtu� Descrip6on, indicate fixtuie type, lamp fype (e.g. T-8), number of lamps in the fixture, and ballast type ('d
included). For track lighting, list the Iength of the frack (in feef) in addition to the fixture, lamp, and ballast information.
2. For proposed Watts/Fi�cture, use manufacturer's tisted maximum inpuf wattage of the fxture (not simply the lamp wattage) and
other criteria as specified in Section C405. 5.1. For line voltage track lighting, list the greater of actual luminairs wattage or length of
track multiplied by 50, or as appticable, the wattage of current limiting devices or of the transformer. For low voltage track lighting list
the transformer rated wattage.
3. List al! fixtures. For lighting equipment eligible for exemp6on per C405.5.1, note exception number and leave Watts/Fixture biank.
� -� 2012 Washington State Energy Code Compliance Forms for Commercial, Group R1, and > 3 storv R2 and R3
2012 Washington State Energy Code Compliance Forms for Commercial, Group R1, and > 3 story R2 and R3 Revised June 201
Project Address ��' � � ���� Date�1 � � } �
�
The following information is necessary to check a permit application for complia�ce with the lighting, motor, and transfonner requirements
in the 2012 Washington State Nonresidential Energy Cade.
(yes, no, n.a.) � Section �Companent �Information Required
LIGHTING CONTROLS (Section C405.2)
♦ Manual lighting Lighting control schedule with type, locations served, 50%
�( C405.2.1
,�
µ16,
co�trols I htm reduction method
Lighting systems automatic shut-off capabiliry - indicate
C405.2.2.1 automatic time method and location served on plans. Note locations where
switch controls automatic shutoff is provided by other method (occupancy
sensor da I� ht controls etc
Override swftching Schedule with locations served - no single override switch
exceeds an area of 5 000 SF
C405.2.2.2 Occupancy sensors Schedule of locations served
C405.2.2.3 Daylight Zones
Vertical fenestration Primary and secondary dayiigh# zone areas indipted on plans
Skylights Skylight daylight zone areas indicated on plans
:40522.3. Daylight zone Lighting control schedule with dimming method and locations
controls served - no sin !e da � ht control zone exceeds 2,500 SF
S fic a tication Spe�c application lighting controls are independent of
C405.2.3 �rols pp 9eneral area lighting and contro�s for other lighting
applications
Means of egress Lighting control schedule with method and locations served.
li htin Note iuminaires that function as both normal and ress.
Display lighting Lighting control schedule with type and locations served
Accent lighting LigMing control schedule with type and locations served
Hotel/mote{ guest Li htin control schedufe with
rooms g 9 tYpe and locations served
Supplemental task Lighting control schedule with type and locations served
�i htin
Non-exempt lighting Lighting control schedule with type, applications served and
ui ment locations
Non-exempt lighting Lighting control schedufe with type, applications served and
e ui ment locations
Location Building Dep�
on Plans Notes
fiJ
` ��
��
C405.2.4 �erior lighting Lighting control schedule with type, features and location
controls served
INTERIOR LIGHTING POWER Section C405.5
'� C405.5.1 Total connected Schedule with fixture types, lamps, ballasts, watts per fixture '�'�)
I' htin ower
�� Space exceptions Space exceptions taken noted on plans or compliance foRn
Lighting equipment Equipment exceptions taken noted on plans or compliance
exce tions form
C405.5.2 Lighting power
Area
� 5pace-By-Spaca
Method
C405.4 Exit signs
EXTERIOR LIGHTING POWER (Si
t,I( � C405.6.2 Total connecied
iiahtino nower
power
�/ I C405.6.1 I9�ounds lightin<
ELECTRICAL POWER SYSTEMS
mpliance form completed — proposed wattage per building
�a does not exceed manimum allowed watta e
mpliance form completed — totat proposed wattage does �� I
exceed maximum allowed watta e
intemally illuminated exits sign are < 5 watts per side
Schedule with flxture types, lamps, ballasts, watts per fixture
Exte�ior application exceptions taken noted on plans or
compliance form
Compiiance form completed — proposed wattage for exterior
I�hting plus base sde allowed does not exceed max. allowed
Schedule with fixture types, lamps, ballasts, watts per fixture;
lumens per watt for fixtures > 100 watts
tions C405.7 ,C405.9, C405.12, C409.2.1)
2Q12
State Energy Code Compliance Forms for Commercial, Group R1, and > 3
de Compliance Forrns for Commercial. Grouo R� a��t �� a+��, R2 & R3
R2 R3
Revisad June
Project Info Project Address ,� Date � b8 �V
� � � �, � � Gf �or Buiiding Department Use
ApplicantName: �� � � ��� � � � � � .�
ApplicantAddress: � �� ¢ �� + I�ii '' �..�
Applicant Phone: /� , •
Project Description � �dew Buitding ❑ Addition j�Afteration ❑ Change of OccupancylConditioning
Compliance Path ❑�scriptive .� Component Performance ❑ Totai Building Performance
Occupancy Group � Commercial Q Group R(R-1 &> 3 Story R-2 and R-3)
Climate Zone � Ciimate Zone �G�j C Climate Zone i��( See WSEC 301.1 for county tist)
Vertical Fenestration and Total Verticai Gross Exterior
Sk li ht Area Calcula#ion Fenestration Above Grade % Verticai
y g (rough opening} divided by Wall Area times 100 equals Fenestration
If complying via the Pn9scriptive path, ���
provide values for vertrcat fenestration, : %� 1 �� _
skylights, gross watis and roof. ti
compiying vra the Component Gross Exterior
Perfamence pafh, these values ane auto- Tatal Skylight divided by Rooi Area times 100 equals % Skylight
fiiled by !he ENV-UA form and cannat be
edited here. � I A ,_
�vt
vert,�, DE COMPL(ANC�
Maximum Prescriptive Fenestration � �,�, AIf�PF�OV�D
Fenestration Area Skyfights �,( p� JUN 2 3 2016
50°/a Floor Area in DLZ O More than 50% of the floor area in daylight zone per C40 .3.1.1
❑ Project has semi-heated areas as defined per C402.1.4 BUILDING DIVISION
❑ Applying wall exception to semi-heated areas ""'"'
1. To be deemed semr-heated the area is heafed but nof cooled, and has a max. heating sysiem
output capacity batween 3. 4— 8 Biuh/ft�. Refer fo C402.1.4 ior requirements.
Semi-Heated Path 2. Semi-heafed spaces shalt be documented separately from other cortditioned spaces — prnvide
se,narate compliance fams for each conditioned area type.
3. Semi-heated spaces may comply under the Prescriptrve or Compo»ent Performance compliance
path.
4. Envelope elements separating semi-heated /rom other conditioned spaces shali comply with
thermaf envelope requirements for an exterior walt.
C'i Walk-in cooler ❑ Walk-in freezer
Refrigerated Spaces G Refrigerated Warehouse Cooler ❑ Change of Occupancy/Conditioning
Refigerated spaces shall comply under fhe Prescriptive Path onfy. Comptrance documentation for
these areas may be combined with non-refrigerated areas in the ENV-FRESCR/PTIVE form. Refer
Project inGudes more than one occupancy typa andlor level of space conditioning. Multipte
Mixed Occupancy and/or compliance forms may be requir+�d. Select ali that apply to scope of project:
Space Conditioning �'�ommerciat ❑ Group R1 or >3 story RZ/R3 ❑ Refngerated Space
❑ Fully Conditioned C Semi-Heated C Low Energy'
❑ Group R2/R3 < 3 story RECEIVE
`Low energy areas are exempt from aN fherma! envelope provisions and com�''b�eYpr��br�V �
fhese areas are not required, Refer to C101. 5.2 for exemption.
�
•
JUN 0 9 2016
LA
PERMIT CENTEi�
Project Address � t1 Date og `�
Commerciai O Grou R R-1 &> 3 sto R-2/R-3 Ciear For Bui ing Department Use
Occupancy Group �i p( ry 1
Climate Zone � za�,e �. O Zone
Change in occupancy or space conditioning �
Note - Proposed UR may exceed Tan7et UA by 10'� per C101.4.4 and C101.4.5
Fenestration Area as �o �ross e�e�+or A� wau area µ Max. Target:
5�11 Iit AI'ed as °/a gross exterior roof area � Max. Target:
5U�/o Fioor Area in DLZ �= 50`"�� of thc floor area in ciaylight zonc per C402.3.1.1
Notes: 1: If verticai fisnestration or skylighiarea exceeds maximum a/lowed perC402.3.1, then Target Area Adjustmentoiall applicahle envelope
e/ements wip be catcufated by the campliarrCe 1F�rm. Refer to sheet on the backslde of the ENV-SNGC fam for fhis calcu/ation.
2: U-factors shall co►rre from Appendix A, chapter C303, or ca/culatedper apprnved method as specified in C402.1.2.
3: Refer to ENV-CMK worksheet for example of how to complete the rows on this form.
Buflding Component Proposed UA Target UA
Provide source of U-factor, a e/ lan # of assembf detaii & ID U-factor x Area A = UA U x A U-factor x Area A= UA U x A
,� R= iD: O �I� � �
a� R= ID: �� Above Deck Insulation set occ.
n R= ID:
� �o R= iD:
�m R=. ID: Metal Buiiding set occ.
� R= iD:
�, R= ID:
w R= ID: Singfe raft, attic, other set occ.
� R= ID:
€ R= ♦Ib ID: � (�%� � �
'� R= ID: , SteeUmetal frame set occ.
a� g R= ID: ,., i
a° � R= fD:
¢ m R= ID: Metal Building set occ.
� � R= ID:
3 O R= !D:
�' o R= fD: Wood Frame, other set occ.
' o
c6o R= ID:
a
O « R= !D:
� R= iD: Mass Wa11 set occ.
� R= ID:
= R= !D:
o� R= !D: Assumed to be Mass Wall set occ.
m � R= ID:
` R= ID:
�, R= ID:
N� R= ID: Mass Fbor set occ.
$ R= ID:
LL m R= ID:
� R= !D: Joist/Framing set occ.
u- R= ID:
F-facto� x Perimeter = UA U x A F-factor x Perimeter = UA U x A)
� R= ID: � N� a ; 8a �
,� = R= ID: Slab-On-Grade set occ.
� � R= tD:
c
° � R= ID:
A +.�
�� R= (0: Heated Slab-On-Grade set occ.
= R= iD:
�o e ► e s n r a alue Area UA Area UA
�� no e � u em��ntsp�n ix va ue . ans mus cgear s a e p�e 1
Subtota! ��� � ��a � �� ��jL�'
2012 Wash�ngton State Energy Code Compiiance Forms for Commercial, Group R1, and > 3 story R2 R3
Project Address �� � �, Date b �
FellestY'dtiOli A�C'ed as % gross exterior wa�l area N a Max. Target: For Building Department Use
Skylight Are1 as % gross exterior roof area µ, Max. Target:
Notes: 1: If vertica/ fenestratiort or skYfightarea exceeds maximum alfowed per C402.3.1, then Tar�et
Area Adjustment of al! appliceble envelope e/ements wiU be calculated by the compliance fam.
Refer to sheet on tha backside of the ENV-SHGC form for bhis calcu/aHon.
2: Provrde NFRC or Appendix A U-facMr far fenestration assemby (combined frame and glezing
periormance).
3: Refer to ENV-CHK worksheet for example of how to romplete the rows on this form.
Building Gomponent Froposed tfA Target UA
Provide source of U-factor, a e/ lan # of assembl detail & ID U-factor x Area A = UA U x A 11-fador x Area (A = UA U x A
�� U=0. ,o: 3X� 0•31 21 �. � ,
�� $ U= !D: Qpaque Swing Doors set occ.
v� O �= ID:
� � U= ID:
0 0 �_ �p; Opaque ro►lup & sliding sei occ.
� � U= ID:
� U= ID:
� U= tD: No�-Metal Freme
o U= iD: set occ.
Z U= ID:
� �$ U= ID:
°+� U= ID: Metal Frame, Fixed
`` @ U= ID: set occ.
� �,
c � U= iD:
�
_ a U= ID:
�° �_ �p; Metal Frame, Operabie
�� U= ID: set occ.
� U= ID:
o U= ID:
° U= ID: Metal Entanoe Doar
a U= tD: set oCc.
" U= ID:
� � U= !D:
o, T U= ID: Ait types
Y~ U= ID: set occ.
� ¢ U= ID:
Area UA
page 2 s„�cota� �.
Page 1 Subtotal �S �j .
Tocomply: Total ���� �.0�� �
1) Proposed Total UA shall not exceed Target Total UA. ,t
2y Proposed Total Area shalt equai Target Total Area. ��p� X�`i .q� %�. �=
Area UA
2t �.7i
3�� ;:
C�lo,.9b ��9 �fr
'�Q •�b �GIad,lleD
2012 Washington State Energy Cade Compiiance Forms for Commercial, Group R1, and > 3 story R2 R3
' � •' . •.
2012 Washington State Energy Code Compliance Forms for Commerciai, Group R1, and > 3 story R2 & R: RevisedJune2013
Minimum Re uirements Use table to determine if project qualifies for the optional
q Prescriptive Option. All components must meet the stated
for Prescriptive Option requirement.
Cliroate Zone Climate Zone 4c/Sb Climate Zone 6b
Occupancy Group AI1 Other Group R AI[ Other Group R
Opayue Elements Insulation Min. R-Value''�
Roo s
Insulation Entirel above Deck R-30 c.i. R-38 c.i. R-3& c.i. R-30 c.i.
Metal Building (with R-3.5 R-25 * R-11 Ls R-25 + R-i 1 Ls R-25 + R-11 Ls R-25 + R-11 Ls
thermat blocks)$b
Attic and Other R-49 R-49 R-49 R-49
Walls, Above- rade
Mass '` '` 4 '0 -1 '`
Metal Buildin R-13 �- R-i3 c.i. R-23 + R-13 c.i. R-13 + R-13 c.i. R-t9 + R-I6 c.i.
Steet Framed R-13 + R-lOc.i. R-19 + R-8.5 c.i. R-13 + R-12.5 c.i. R-19 + R-14 c.i.
VVood Framed and Other R-2t int R-21 int R-13 + R-7.5 c.i., or R-21 + R-5 c.i.
R-21 + R-3.8 c.i.
Below Grade Wall Same as above de Same as above de
Flaors
Mass R-30 c.i. R-30 c.i. R-30 c.i. R-30 c.i.
Steel Joist ( er footnota c) R-38 + R-10 c.i. R-38 + R-10 c.i. R-38 � R-10 c.i. R-38.0 + R-10 c.i.
Wood Framed and Other R-30 R-30 R-38 R-38.0 + R-10 c.i.
Slab-On•Grade Floors
iJnheated R-] 0 for 24 in, (�vith R-10 for 24 in. (�e�ith R-10 for 48 in. (w°ith it-15 for 48 in. (�vith
thermal break) thermal break). thermal break) thermal break)
Heated 12-i0 perimeter 8r. R-10 perimeter & R-10 perimeter & R-10 perimeter &
under entire slab under entire slab under entire slab under entire slab
Opaque Doors '.Vtaximum U-Factor
Swinein U-d.37 LJ-0.37 U-0.37 U-0.37
Roll-u or slidin R-4.75 R-4.75 R-4.75 R-4.75
Fenestration 0-30% o K'all Assembiy Maximum U-factor (NFRC Rated)
Yertical Fenestration
Iv'onmetal framin U-0.30 U-0.30 U-0.30 li-0.30
Meta( ftamin (fixed) i;-0.38 U-0.38 IJ-0.36 U-t).36
Metal framin (o erable} U-0.40 U-0.40 U-0.40 U-0.40
Entrance doors U-0.60 U-0.60 U-0.60 U-0.60
S ti hts
S li hts U-0.50 U-0.50 U-0.50 U-0.50
Fenestration 0-3l1% n ii'all Assembly Maximum SHGC Factor
Vertical Fenestration PF<0.2: all orientations - SHGG0.40
0,2 5 I'F < 0.5: north - SHGC-0.4�i. all other SHGC-0.48
PFz�.S: north - SHGC-0.48, all other - SHGC-0.64
Sk li hts SHGC-0.35 SHGC-0.35 SHGC-0.35 SIiGC-0.35
For S[: 1 inch .= 25.4 mm. ci .= Continuous insulation (see foofiote fl. NR .= No requirement.
LS .= Liner s}stem--A continuous membrane installed beiow the purlins and uainterrupted by ftaming members.
Uncompressed,unfaced insulation rests on top of the membrane betH•een the purtins.
a Assembly descriptions can be found in Chapter 2 and Appendix A.
b�h'here using R•value comp[iance method. a thermal spacer b3ock sha11 be provided, othenvise use the i:-factar compliance method
in Tahle C4�2. t .2.
c R-5.7ci is aliowed ta be substituted with conerete biock walls complying with ASTM C90, ungrouted or partially grouted at 32
inches or less on center vertically and 48 inches or less on center horizontally, with ungrouted cores filled with materials having a
maYimum thermal conductivity of 0.44 8tu-in/h-ft2 EF.
d Where heated slabs are below grade, below-grade walls shall cc�mply �vith the exterior insulation requirements for heated slabs.
e Steet tloor ioist systems shall be insuiated to R-38 .+ R-1 Oci.
f For roof, wall or floor asscmblies where the proposed assembiy has penetrations > 0.04%of the area, the assembly is noi
Element:
SKETCH OF E'L,EM,ENT
Note; ;Itiake c:��ies of this fcm^, fcr avery buiidirg e;ement.
i''�i. y�D� ?A� o. L
i�u�z l�ra��'a �
�=ramirg 4atio (ifi apaflca��e; =
i ; Thickness � R! tnch i R Vaiue � R Value
' Materials � inches � Thickness + Solid Cavi� �
�' } ��� � ...,_.,_._.,,__ + � f d.�' f
� �}{ b`�-� -- - y��-' ._ t .__-__ ��� � �s(A � r
��' � �� ' __ __ , .__. � .�_�'.____.__ ____.i
__4�..i��'_1.�.l.�.�._..o►.� ��� _.._.__ `_� f .. ._ .�__�-.____ .._._�,
�,: _, _�.I?�L_�__�_____r_.__;
: '� j__�!��Nt��l:tk_�.�.jc�,l .�. ��__.,�,�._ ; lb.-f� � �
� ^ E___ `�__�'�g �i G�KP � I�D ; - -- ' _...��� � �._.__.._._.__;
' ",'.,.� �� .�.IZ�._._._... � __._._� .___.._ � .�....._Q, t� l _ I
i a� � y ___ -»--�-- -- "".
. �%� .__ �.._______._._ ' _ ! r . ,
'U)'s
�?l;i� __
` � i i
, . .
i o±ai R Va;ues` 2�I. (p s '
__._..;__._._.._..___.;
u Va�ue = vR� �•b 2�j ` ;
— ,
, --___..,
Average U Vaiue = � �
;
�a;us '�r E'ement rR vg.� _ (U Sc rd !Fram,ng 4sio; - :, !Ga: ,; .�acc:; % 2
�?r�a of `;ement� =
'�; °a or �iemeni is ne: area af�er c�en�ngs sucr as �oors. w�racws ar.c
sy?igt?rs �'�ave �eer, subtrac�sd,
� PER�IaT �QOR� COP�
PLAN REVIEW/ROUTING SLIP
PERMIT NUMBER: D 16-0149
PROJECT NAME: JOHNSON CONTROLS
SITE ADDRESS: 3315 S 116 ST - SUITE 115
X Original Plan Submittal
Response to Correction Letter #
DATE: 06/09/16
Revision # before Permit Issued
Revision # after Permit Issued
DEPARTMENTS:
A� A�WG �• I S' �� �'w�, ,$1�i� �� l�0 �� r�, �•'`4'�►`�
Building Division � Fire Prevention Plannn�g Division �.
� � �� G � i�• l (t
Pub�c Works � Structural � Permit Coordinator
�
PRELIMINARY REVIEW: DaTE: 06/14/16
Not Applicable ❑ Structural Review Required ❑
(no approval/f�eview required)
REVIEWER'S INITIALS: DATE:
APPROVALS OR CORRECTIONS: DUE DATE: O7/12I1G
Approved ❑ Approved with Conditions d
Corrections Required ❑
(cof•rections ei�tered in Reviews)
Notation:
REVIEWER'S INITIALS:
Denied ❑
(ie: Zorring Issues)
DATE:
Pernait Center Use Only
CORRECTION LETTER MAILED:
Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Stafflnitials:
12/18/2013
PRECISION BUILDERS INC
Home Bspanol Contact
Safety & Health
Washingtbn 5t�t� Deparbnent of
Labor & lndustries
PRECISION BUILDERS INC
Owner or tradesperson
Principals
SANBURN, SCOT DEAN, PRESIDENT
SANBORN, ELIZABETH ANNE, SECRETARY
Doing business as
PRECISION BUILDERS INC
Claims & Insurance
PO BOX 98609
DES MOINES, WA 98198-0609
206-878-2948
KING County
Page 1 of 2
iSearch L&I �
<�-7Index Iielp M1Sy L8:I
Workplace Right� Trades & Licensing
WA UBI No. Business type
600 553 713 Corporation
Governing persons
LIZ
SANBORN
SCOT D SANBORN;
License
Verify the contractor's active registration / license / certification (depending on trade) and any past violations.
Construction Contractor Active.
_..........._.__. ..............__ ....._..,........._.._......
Meets current requirements.
License speciatties
GENERAL
License no.
PRECI61151C2
Effective — expiration
02/22/1985— 01 /19/2018
Bond
DEVELOPERS INS CO $12,000.00
Bond account no,
415171 C
Received by L&i Effective date
01 /14/2002 01 /19/2002
Expiration date
Until Canceled
Insurance
_..........
West American Ins Co $1,000,000.00
Policy no.
BKW55554018
Received by L&i Effective date
06/29/2015 07/15/2013
Expiration date
07/15/2016
Insurance history
Savings
No savings accounts during the previous 6 year period.
https://secure.lni.wa.gov/verify/Detail.aspx?UBI=600553713&LIC=PRECIBI151 C2&SAW= 6/29/2016
u
�
YICINIT't' M�4i'
N.T.B.
• 1 � � / ' � '
NO���
� �UI1�I�INC� � 51�'� St�tls�'ICS .
Bu(LDINC� GOp�: _ I�C 2012 � ? �,�
zONINCx: M-1 ���,��"�,-��� ������'J: �` ` ��
5�15MIC zON�: ZON� 3 � � �,�
u�
PLUMBINC: � �-
CONStRUCTION tYPE: III-B SPRINKLERED HYAC MODI�IC,4TION8 �
' OCCI,lP,�ICY C�ROUPS: B 4 S-1 �� �'
_ �4�LOUJA�L.E �UILDING ARE,4: UN�IMI1'ED, 60' YARD ON �41.L SIDES, ELECI'R1CAL �, �
� AND �U�I.Y S�INKI.�RED SPRINKI.ER MODIFICATIDNS
� �► QF T�PI,4N1': 3,146 SF
Ai�4 �F I�MODfI.= 341 � C�FFICE
�
�41�,4 OF �3UIl.pINC�: 3i,106 � .� J 0 Q
-T,4X PARC�� NUMB�i�: ID923m4-9068-�m � _ � }
_ � � a .�`n ,
-L�Cz,4L D�SC�:IPtION:
. �N�IU P,4�?G��S �4,�3, � C OF TN� CITY OF TUKWILr4 �-
m
. �30UND�4RY LIN� ,4DJUSTMENT '�89-8-8�,4 ,4S m
RECOfi�D�1� UND�i� KINC� COUNTI' RECOi�DINC� NUMB�R W 3 Y
900312148�, �CORDS O� KINC� COUNTI', UJ,4SNINC�T01�: o � w�
. a o o c=,� o
_ SCOP� 0� UJOfi�K
R�MOYE M'I�RIOR i��t 8��4�Ii� W,41.1.5 P�R P1.�1, IN�TALI. NEW i�.L I�IC�Ii' OFF(C� W�..L
>�
(N5�'ALI. i�UJ �P�NDFT� CEILI1+iCx IN i�1�UJ C,�ICE �,4, N�W Fli�tl�5
MDO�Y LKs�ITB, SPRINKI.ER ANp HY,4C UNp�R �PAi�4TE P�i�`"ili'S
�
_ �
�
� 0
o �
� �
_ _ . � m
c.�
, N �
� o N
�
- � � . • i
�
, Q �
� �
�
>—
- c/�
� � ���
� 00 00 �
� � �Z
�_�
,. '.�. d�- N (n
' � � .�.-. � Q
III I It�I � Q
���� o� W��� t�l�t _� o o z'�.-
� � �: �'� I � __._. �� o �
w
i"��l��l�' f M��O���'I�1��' �� ��' I �, � w °° � �
r
,._ ox `0Q
�1...1�C�. ��, 331� 5. 11� 5�'., 51,� f�'� 11� _
. �
�.� °'��
. �
, �� � . _
-- � ��
��,viEv�'�'�o�' �
�, C(��llp�-IAN�� �
, �11�O�C� 5�' ���'�������� .
' ��6
au� �- � � � �
-- ��� � o
• ,�� �� `�u �
L.D��� ��V►S��� i�4
��w"� BU� � �
: P��vt�� �4 ' �
� r,,,�
. . Pl�n r��i��r� ��p����l i� �ub�e� to �rror� �nd �n�i��ior��. � � �
� �
: ��R����i �f �a�ns�r��ti�;� ��ur�t�nts c���s ��r �c�;rao�i�e � �
ti�� ��ial��i�� �� �.��r �do�,��d �Qd� �r �r�in�nco. ����s�t � "�
of appPo�ac� o-�i�9d ��py �nd ���ii@��a i� ��kr��w1�����1: ��
� �
��'' � � W
: i3a�e: �� -�� � �r E"'�
�
Ci�y t� �'uk�r+i� Q �
�3�lil�Di�C �IV�S� � h"'� U.�
,-
� � ^
9J _ �
: . . : �.._ REVtSIONS F' �1-� W
No chang2s shail b� made to the scopa '� � h� [--1
of work U�ithot,t prior approval of � [—� �
- Tu6,wila Building Division. W� ry �
. l��S�• Fi •� ,. F-+-1
1 " _ � �' , .
. Evis3�n;, will requ�re a new plan subm�ttal
ancl may in�ciu�e additional plan revievr fees. � p� 0.--�
a��
. „
��c�iv�o � � � � o �
CITV CDF �'UKINIL E ,,,� � �
JUN 0 9 2016 � ' ' � �
��W�
���n�ir ����r�� w C—+ .--� �
h����
�c �...� � E�
- �..
. _ �
,,.,..--------.- . _ ... . _ .. . - --
�x. w,a�Nous�
S�M( N�,4tEp
NO CNANC�S
0
NEW SUSP�NDED ACOUSTIC,41.
C�11.INC� ,4i' 8'-6" ,4�F TO M,4tCH
�Np TI� INtO �XIS1'ING C�RIp
PA77Ef�1, tILE 1'O BE
,4RM5i'RONCx 2'X4'Xl" ARMSTRONCx
OPl'IM,4 OP�N PL►4N SQU,4RE
L.AYIN �3153 W/ PR�I.UpE 15/16"
EXP05Ep 1�E GRID. (5EE alC2) ;
5
C
�
�
r•n
�
�
N
�
�
r
_ 1��U� �����C�'�l� C� I� 11�C�
NDi�tN � �I `�:
SC�4�E: I/8" = 1'-0"
� IC���'INC� C��G�.
1. U51NC� SPACE BY SPACE 1'AB1.E C�5.212I
341 SF O� N�W O�FIGE X 0.98 WATTS = 334.18 W�4TTS A�L.OWEp
�fNf S� �10�'�S:
C,4RPEt TNROUC�I-IOUT: MIL�IKN MOpULAR TIL�, SOUT'N�RN ,4NA1.00rt,
P�4NOR�"IIC-P�4111 SIC�N,4�, PtJRCHS�p �Y JCI, INSt,4��ED BY C�C, PROYIp�
QU�d�ITITY 1'D JCI.
�3AS�: GOY�D i�IBP�R �3ASE-ROPP� 193, ��.,4CK BROUIN, P�IRCNASEp �3Y JCI,
INST,4J..1.Ep �1' C�C, PROYID� QUANTIi'Y TO JCI.
�OR i'AINT NOTES, SE� JCI pRAWINCx FOR ACC�Nl' aNp �IE�D PAINT, 2 CDAtS MIN.
������IL.i!"�'tl.. I VL/���%
R��R t0 JCI pR,4lUll�xS �OR NEUJ POUJER, Da�'A ,4Np �Ui�IITUR� POUJER
REQUIR�M�Ni'S.
C��1���� l�Ot�S:
RE��R �0 JCI DR�4U1(1�xS �OR C��NER�� PROJ�Ct NOT�S, CONStR�.lCtION NOt�S,
COi�lER CxUARDS ON AI.L W,41..� CDI�RS 7HROUGHOUt, ,4Np 5YM�01. N07�S.
�
r
�
in
31X4X3i' i�t�SCENT Fik'CU�S � 88 WAti'v i'�R �IkTt� = 264 W,4TTS
CEN
11X4X2T �I..UC��N1' �IX1UR� � 66 lt�►1i6 F'ER �IXTUi� ■ bb W�4Tt5
TOt� I1�T,4�l.ED LIC�HtS = 330 It�4TTS
, � ��i��r��� �0��5:
t N�w sP�cE to H�►vE vccuPANc1" �:r� ,4Nu M,ar�. sw��tcNiN� �3 uuaY�
v��r wit� t��wr
z. r�o� �acist� swirc,�� c� r�w �,a�c�s
3. i�W �',4G� 151�T WIt�IIN p,4Yl.�xNT ZO'N�
4. 1� CNAJ�xES TD �XISTINC� L�NTINC�
0
1
1
1
1
1
1
1
I
1
1
� N��J SINC�LE
EXIi' PaTN
!
1
I
�
�
�
/
i
1
!
1
1 0
1
1 EX. WARENOUSE
� S�MI H��4tEp
� NO GNA1��S
' 10V
1
�
1
� RE�OCAt�
� �XI �
�
�\
�� NEUJ OP�N Oi�ICE
�� 10i
�\
��
I
I
I❑
I
� �x oP�N o�IcE
� I�i_�n
I
M�N
�4
�
N
y: 9'-����
��� ����� i����=
NORTI� SC���: 1/8" = 1'-0°
N�UI OCCUPANI' LOAD: Oi�CIE 1,5�4��1/100=15 OCCUPANtS, �
WAi�N0U8� 1;602�1/500 = 3 OCCUPANTS. TOT,4� OCCUP�4NT
L0,4p = 18 OCC.
PROPOSEp EXIT tR�41/�L pISTANCE SIi��� �XIT IS 122 �.�
I��U! ���� SC���I���: N,ANDLE TO M�4TGN�XIStIi�'s
Nl N�W 3'-0� X 8'-0" SG WaOp DOOR � Ul000 J,4M� TO M,4TGN
�XISTINC� ,�4Np 01� R�� �CISTIPtCx, 2 PA(R �ITTS, l.,4TCN�T,
GLD�R, i!�" M,4X TNRESNDI.D, il�,4tll-�TRJP 1031)
I��W W��� SG���I����
,4. INTERIOR: 3 5/S" X 25 C��4 8?E�L gTl� �4T Z4� O.C. UlITN SC�ID
MSU1.,4TION ,4ND 5/8� C�YP �D F�►GN �ID�.
u
8. P�RIM�'i"ER: 6"X2@C�,4 S'i�El. S'i'� ,47 24� Q.G. TO ROOF S'it�JGTUi�
�u�.�. u��r wir� o�t�crior� �ac�, �-z� �arr �u�.�a�ioN
WITH R-10 CONTI�� �i210R IN�W..�4TIt?N, 5/8" C�YP 8D
wa�t�� 5�r� �u�.� ���t, �ro �� �� c���� a� c��c�
Sip�. (0.2a423I
�:V;+t �5'.� �,��,��„•�, �. .. .
]
R�MOYE EXISTIN�x WALLS
ANp p00RS
SAYE DOORS �OR R� US
F--- ---
�/
_�
❑
R�MOYE EXIStINCx IUA�LS
ANp p00R5
SAY� DOORS �OR R� US
M�N � � �
) O �L====�
, O �
���� ��0�� ��,��:
NORTN SCAI.E: 1/S" = 1'-0"
���� I �1���5:
1. R�MOV� �XISTIi� WA��.S ANp DOOi�v a5 SHOI�I. 5,4�Y,4Cx� p00R5
�OR OU�I�R
Z. i2EM01/� EXISTIi� UN USEp CABELII�
3. REMOVE ELECTRICaL AS R�QUIRED, PULL t0 ,4 NEW J-BOX ,4BOYE
C�ILINCx ANp LAB�1. WItN CIRCUIi' NUMB�R �4NP PA�NEL NtaMBER
�4. P�47CN AND R�PAIR EXIStING UJaLLS, �LOORS �4Np CEILIi� ,4t
REMOVED UlAL�S
5. MODI�Y �Xlsi'll� SPRINKL.ERS A5 REQUIREp AND EXTEND i'0 NEW
O�ICE
6. MODI�Y �X. NV�4C ,4S REG2lJIR�D AND EXPAND INl'0 N�U1 O1�ICES
(YERI�1' CAPACItY)
�. MODI�1' SUJI�'CNINC� 0� LIGNTS ,45 R�QUIR�p �OR NEUJ SPAC�S.
�x. �u�� N���N�r
p�M1811� WA��
EX. NC
R�STR+
26'-5"
�X. DOCK NICxN L.OApING
�
�9 I ES
I
I
I
I
I
i
I EX. SINIx��
� EXIT PatN
I
�
I
I
I
I
i
�
I
�
i
I
I
I
I
4
EX. U1,4RENOUSE �
S�MI N�A?Ep �
NO CNANC�ES �
I
I
I
I
I
I
i
EX15T �
EXI I
E�
P �x oPk'�
ST � o1�ic�
EXI I
M�N
�� U � I I _ I
� �
�- �
r � � � EX.
�� E� � OFFIC�
� I E3
�O
�x. cot��� l
�" � a. . � �.'
\\
�X. OPEN OFFIC� � �XIS7 .
� �XI �2
\��
2�4'-�4���
�x. �u��. N���Nt
p�M151NCx W,4L.l.
�
�
N
9'-8�"
�Xf 5�'II�C� 0���1�� ��00�
NORTN � �� `� �
5C,4LE: 1/8" = 1'-0" .
�XIStINC� OCGUPANT �OAp: OFfCIE 1,203�1/100=12 OGGUP�4N7�,
IUAR�NOUS� 1,9�3g1/500 = 4 OCGUPANTS. tOt�4L OCG .� �����Ft
�o,4p = 16 oCC. �t�.�i�4�p�iA�G�'
�xIS�'li�lCrt ExIT 1'RAVEL DIST�4NCE SIi�L� �xlt 15 1� ��,�p�p�►�'�
:::i , u� 2 3 2��6
�Xf �i�I1�C� �00� �Cl��l�l� �• ,
E1 EXISTII� 3'XS'�o" IN5UL,47ED 51'ORE�RON1' ,�OR �'�u�S�Ot�1
��� �� p1V�
EXIT PADD�.� �V11.
�2,E3 �X. 3'XS' SC WODp p00R, UJp J,4M�3, L,4TGHS�
E6,E�
�S,E9 EX. 9'XI0 01/ERN��D pOCK NICzN p00R
��
;4�*�..� �,,,
� �
� �r 3
�` � ♦
� � � ' � °�` x s� ti
f }
� }J t� ' j 4 , _ �°�
�, , 3 / � �
���.s�a,�� i y yrf� 3�
�
REC�IVIED
CITY �Ir" TUKWILA
JUN 0 9 2016
PER�Ii CEiVTEf�
�'� e I �5
� � � N ",
��4 �
� t �►
�� �. �, � �
` �: �
.
�� .
f=� _
�� `
'���� �t
;r
�,
, >;
�, ,:
� , ,
T wf
�
k . ;
? � ,
�� �
�
;f � . J,
�� ,� � � ;,;:
��, ,..
,� £
�
� �� yY
�y � � �
�Y
rs
;r
`.
57 � �
^' � • � �
,
�3� °'
�� 3
��, �i
� �
r �{St i,.
� r�
4 f
s �,
� �
� _�
�
,� ;�
� � :�
��i a
� ;,F
; � ��
�� � �
.� >
t;�
� • ��.
t
}', 4a�r
fy
• l'{5:,,
� Y�
�; � 11 ;�
RY ir.
§�
� s;- ,
�
3� � =t;
�� �f
, J;
�F ` r
� �
f� � ;
f{: .
�f:
�� �
� � �
�� .
r{� ` x��
, �,:�
• �
. . �•
0 0
�Md- N
cci co
N N
Z
t= �
�
m
�
�
--r
��
�_�
� vi
� �
Z�
� "
W
miJ—ao
tp �'-
�Q
��rn
UJ�S�: 1.9�3 5�
O�� I C� : 1,2 �3 5� i�R TO ,�NN�4N C.ONti�OL � POI�R D,41',4 ,4ND
TOT�4�: 3,1�6 S� s��� c� ��atioN �wn Misc. �cauit��rs.
C:1Documents and SettingslAll UserslDocumentslCAD11987-198918734-4 3315\JOHNSON CONROLS 1151cd's �-07-161T-1.dw�, -.
0
;� : .
�
�XIStING C�IL(NC: HAS R-19 INSIl�Atl�l
�X. ROOF STRUCTUR�, 2X StII�ENERB
Si'EEL STUD D�FLECtION ?RACK
3-�8X I S/8" SCi�lUS EACN
StI�F�NER At 24" O.C. PROYIpE
I 5J8" GAP WI7N p�EP L�Cx TRACK
R-30 BatT INSULATION
TYP. OFFICE tUA�L
�RAMINCs W/R-2� BAT?
INSIJLATION IUItH R-10 CONtINUOUS
RIGIp IN�JLAtION UND�R GYP BD.
6" x 20 GA
$iE�L StUDs �
2�1" 0/C
5/8" Gl'P. BD.
�ACH SIpE �
sc�,.�: �-irt�� _ ��-���
SPACER BAR OR �1�R SU�tABLE
5Y5t�M, t0 KE�P P�RIME'1'�R
COMP�ON�Nt3 Ft�OM SPR�ADII� APART,
s�
GROSS RUNN�R
MAIN Rt�WER —
��
� 4' MIN. t�l-ATTACN�D WALLS
IN. 2" L A1�LE
NOTE:
A17AGN G�ILIt�s AND GRID t0 WALI.
AT�SI.� lMOULDINrs) At 7U10 ADJ,4CQJ1'
UlALLB vIA POP RIvE1'S.
4 M1 GA tUIi�S WItNIN 1" �
/
�
••� �/•" � �
sc�u.�: i-i�z�� = r-m,�
3 5/S" M?L SiUD
2x UJOOD B1.00KINCs
11/2" x IUDOp JAMB
5/8" x 1U00p StOP
�1'10KE vEAL
DOOR
I �xlstlrt�
�,� �YP BD. �ACI�1 SID�
n�s
3� LIGNt �IX'Ni�S t0 BE P031tIV�LY At?AGN�D t0
MAIN AND CR083 tE�B. AND IF OYER 56� h'�JJSt 6�
INpEPEND�NtLY �PPOR?ED.
4) PARTI710NS C�AT�R THAN b' TALL N�ED
INDEi�ND�Nt BRAGI1�ICx YIA SPLAY IUIR�B
lS£PARAtE �ROM ANY 0?H�R lUl�B). PARtI?IONS
6' OR L�SS NO A1?ACHMENt 15 R�Qllif�D.
5) vPRINKLER F�f�AO PEN�7RAt1�18 MtJgt NAv� Z��
NO��: 01I�R51XED 7RIM t0 A1.t.OlU I" MOYEh'i�Nt IN ALL
�PENQrION Ull('�3 t0 B� 12 GACs� At 4' DI�CtI0N5.
O.G. W/ AiTAC4�1�Nt D�YIGES C,4PA�1.� b) MANI,�AGTUf�R CERTIFICATION OF COMpONENT
OF SllPPOR7(Plrs 100 Pt7l�IPS. p��:pp�,p�,�� ,q�,�p p�RiODIC SPECIAL It�PECtION
p
NANCs�R � P�R(MEl'�R WIR�S 1�7 8E �� 5YS'i�M IS I�QIiIRED.
P1.lJM� IUItNiN I IN b Wl.�SS COUN7�R � J � CEILINCs AR�AS EXCEEDMCx 2500 SF, A SE(Sh11G
SLOPItyG WI�S AR� Pf�OVID�D c�p�RqtION JOINt OR �ULI. H�ICaNt WALL PAR7ITION
tNAt Bi�AKS tNE C�ILINrx SNALI. B� PROYIp�p.
CRp� TEE GG�Ct10�11 N0�5� 8) A�1. CRO� 'i��8 51�lALL B� CAPABLE OF
�
ARfi�ANfsED AT 90' FF?OM EAC�I CARRl'INCs 7F� DESIGd�I L0,4D UlIT4a0Ut �XC��DINCs
Oi1�R AND At AN ANCxLE NOi �) M,41N BEAMS 1�E5 AND GROS5IEES fhUSt 8� D�I�CtION �G1UAL tOY�m OF ItS SPAN.
Exc�EOIN� d5•. l.ocatE N�av�r purY wi cor�EcrioH st�tHs oF �m0
R�5?RAINt PAN�LS At 12' O.C. IN ppWpg M C(�1pRESSION t TEN510N. 9) ,4u U11R� TIES ARE TO B� TH(2�� TIC�tT TUid�S
E,4GH DN�CrION ,4TJD tUItNIN 6' dROIAID ItSEL� WItNIN 3 INCN.
OF �ACN IUALI.. Z) C�ILMCs Ai�AS C�a'I�R tNAN 1000 SF Ml1ST HAYE
ti�,41N�� C�I�fN�
l.AtkRAI. FORG� BRACII�{ts YIA pI�CZUNAl. �PLAY
WIR�S, LIMItfN�s MOVEM�N? t0 L� THAN U4' AT
Nt
POI1J7 OF AttAC1�9"f�NL
�'�(L5 (MEE�'S IBC 2�12 SEC SQ?8 ,4ND ASl'h1 C 635 ,45TM C 636 ,�a� asc� �-IDz�
�g
�OR WAl.LS GREAT�R
TNAN 8'- 0" IN
WlOtu WI7FI011t AN
INtER�C711�K� UJALL,
PRovID� l2ga. Wif�s
SPLAI'�D � 45 t0 AN
EY� SC1�W � ROOF
AND tOP OF WAL�
AttACI�I tOP RI�WER
tR,4CK t0 C�IL.II�
C�RID IUItN 2 - +46
x 1.1/8" L�1Cx
SCR�U�'i At Z��O° O:C.
TYPICAL STlJ05 - 31l1",
25Csa. STEEI. B 24" O.C.
(�OR IUALL INSULAtIC�I S�E
P1.AN) 5/8" GYP. BD. EA
SID� lFl.l�N FINISf�!). —,
v
� 3/4'
3 1/2"
I I I . Wfi�� �� I��J��li I�� t�.�� (J� �IV�
sca��: �-in�� : i�-m��
r�s
tYPICAI. tUALL
FRaMIN�s
AitAC+�160iCOh1
TR�4GK t0 COtJC.
�LOOR W/ POUJDER
DRIYEN ANG-IORS, NIL71
OR APPROV�D, �° �MB�DM�Nt,
0.131" DfA, At 14" O.C. _�
. : � . ��. a-� �
. o � .� .a.
'' ° ' � � n.� a � I.� • � ° ,
a. 'a � � u� � .
5/S" C�YP. BD.
CONC. SLAB ON CxRADE
V,41.ID �OR �01'N INTERIOR AND PERfM�TER WA�LS
�f-4�J.- I � 5���
, � �Cr41�: I-i/2' = I'-0u
INSUl.AtION
I/1" CsYP. BD. OR
CEILINrs tILES BRAG�D OR
9tRAPPED tOGEtN�R t0 PROYIpE
AIR tlCxHt ENCLO�IJi� tU/INSULATI�1
AB01I� - S7EEL S1UD �R�'11NCx � R�G�LIIf�O
� 3" AIR CsAP
O O O
PARABOLIC LENSED �L.1J01�5CENt �IXI1lR�
�XISTIi� C�II.INC� HAS R-19 INSU�ATION ON 70P WI7N �IC�NT PR07�CtI0N.
PfaoY��� rJ�w L�c�Nr Box Piaot�ct�oH r�R Ex�stl� �ND t�vvip� r�Ew
R-3¢� IN;3U�,4tI0N GON?INIaC,�JS INSUL,4tI0N ON t0i' C�F 1�W CsRID.
� � 1�1'� I � ( /� i t�� ��� I �C I ( �I �4
+�
sca�.�: i-in�� . r-m��
1
v���° ��'��'�
RE��p�'P!�
��'� ��p`�����
� 5��12 3 2�,6
. .�u�ii�►
���1 �� p���S��N
� BV�1.�t
R����V�D
CITl( 0� iUKVUILA►
JUN 0 9 2016
PERiViIT CENTER
���t�� ���� IV���S.
i) H�At IS vIA GAS, NO �LECTRIC HEA't ALLOIU�D
2) PROVID� YAPOR ON AI.L WALL TO '1'� W,4�1 SID�
3) CAaJLK AND vEAI. AU. OPENINCxg t0 OLI?31p� OR IJNN�At�D vPAC�3
It�LUDINrs 11��4tHER-StRIPPING At Al.l. pCfERIOR ADORg.
d) MAXIMUM ,4�LOU�4BLE LOAD POR °�IUItCN IS 80� �OF 10 ,4MP CIRC1JIt.
5) �OVIDE R-30 It�lSIU.AtIOi�i ON TOP OF �f'. AGOUS?IC CEILItyG
wRENTB OVER LIGHTS
,y) �XIStiNCz I" INSUl.a'�D.,�GG1.AX(Nrs C�YI.I'I'� 14 lll=0.4i) ISHCaG = 034)
-�) ENEfasY CODE COh'iPI.IANt VIA i'R�'O�CCRIPtIYE OPTfON
R
O°7] M � 1-
t� co � z
�=r
dr�- N �, �
r..�-. Q
Q
O O z, � .-
�v m J
I— 00
Z ' �Q
�
= Q �W
LL li �— UI �
�
o �
�
_ e�
�
1 �
J , �
�/ �.
� �
� �
�
�/� �
V 1 ►�..�
� � ��•{
� � �
� � �
��
�°°� 'd�+
P�—� W
� N
(,� � r--+
���
��
� ^
�
H� �
w�`��
���c�
� ��
� � �
a Q '� . „
� � � � �
F ��a
'� ••� ~
� � �.
Ey � � �
� � �
.� �.3 �'J -E-�
�
.Y.._ �
C:1Dacuments and SettingslAll Users\Documents\CAD11987-1989\8734-4 33151JOHNSON CONROLS 1151cd's Q8-07-161T-1.dwg, -, .