HomeMy WebLinkAboutPermit D16-0170 - KENWOOD MANUFACTURING - BREAK ROOMKE OOD UFACTURIN G IN C 1131 ��NDO�TER P W D 16-017 0 � City of Tukwila • � Department of Community Development �„r ,�; • 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 '' ` Phone: 206-431-3670 Inspection Request Line: 206-438-9350 Web site: http://www.TukwilaWA.�ov DEVELOPMENT PERMIT Parcel No: 3523049102 Address: 1131 ANDOVER PARK W Project Name: KENWOOD MANUFACTURING INC Owner: Name: AMB PROPERTY CORP Address: 60 STATE ST STE 1200 C/0 RE TA , BOSTON, WA, 02109 Contact Person: Name: KATE MOLLESON Address: Contractor: Name: 311 FIRST AVE S, SEATTLE; WA, 98104 C P CONSTRUCTION SERVICES LLC Address: 263177TH DR NE , LAKE STEVENS, WA, 98258 License No: CPCONPC920NH Lender: Name: Address: , , , DESCRIPTION OF WORK: Permit Number: D16-0170 Issue Date: 8/16/2016 Permit Expires On: 2/12/2017 Phone: (206) 324-4800 Phone: (425) 345-0830 Expiration Date: 11/14/2016 TENANT IMPROVEMENT - IN EXISTING OFFICE. REMOVE AND EXISTING CLOSET TO PROVIDE A NEW BREAKROOM. NO EXTERIOR WORK ON THIS PERMIT. Project Valuation: $40,000.00 Fees Collected: $1,415.34 Type of Fire Protection: Sprinklers: Fire Alarm: Type of Construction: VB Occupancy per IBC: B Electrical Service Provided by: TUKWILA Water District: TUKWILA Sewer District: TUKWILA Current Codes adopted by the City of Tukwila: International Building Code Edition: International Residential Code Edition: International Mechanical Code Edition Uniform Plumbing Code Edition: International Fuel Gas Code: Public Works Activities: Channelization/Striping: 2015 National Electrical Code: 2015 WA Cities Electrical Code: 2015 WAC 296-466: 2015 WA State Energy Code: 2015 2014 2014 2014 2015 Curb Cut/Access/Sidewalk: Fire Loop Hydrant: Flood Control Zone: Hauling/Oversize Load: Land Altering: Volumes: Cut: 0 Fill: 0 Landscape Irrigation: Sanitary Side Sewer: Number: 0 Sewer Main Extension: Storm Drainage: Street Use: Water Main Extension: Water Meter: No Permit Center Authorized Signature: �� Date: d� � I hearby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this development permit and agree to the Ss�tached to this permit. Signature: —� Date: O L� /.� PrintName:�//_ „�� r,�rriGll�,�itP_.ti. This permit shall become nuil and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: ***BUILDING PERMITCONDITIONS*** 2: Work shall be installed in accordance with the approved construction documents, and any changes made during construction that are not in accordance with the approved construction documents shall be resubmitted for approval. 3: All permits, inspection record card and approved construction documents shall be kept at the site of work and shall be open to inspection by the Building Inspector until final inspection approval is granted. 4: Partition walls shall not be tied to a suspended ceiling grid. All partitions greater than 6 feet in height shall be laterially braced to the building structure. Such bracing shall be independent of any ceiling splay bracing. 5: All construction shall be done in conformance with the Washington State Building Code and the Washington State Energy Code. 6: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, welis, and other excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of this requirement. 7: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206-431-3670). 8: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center. 9: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 10: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila PermitCenter(206/431-3670). 11: Portable fire extinguishers, not housed in cabinets, shall be installed on the hangers or brackets supplied. Hangers or brackets shall be securely anchored to the mounting surface in accordance with the manufacturer's installation instructions. Portable fire extinguishers having a gross weight not exceeding 40 pounds (18 kg) shall be installed so that its top is not more than 5 feet (1524 mm) above the floor. Hand- held portable fire extinguishers having a gross weight exceeding 40 pounds (18 kg) shall be installed so that its top is not more than 3.5 feet (1067 mm) above the floor. The clearance between the floor and the bottom of the installed hand-held extinguishers shall not be less than 4 inches (102 mm). (IFC 906.7 and IFC 906.9) 12: Extinguishers shall be located in conspicuous locations where they will be readily accessible and immediately available for use. These locations shall be along normal paths of travel, unless the fire code official determines that the hazard posed indicates the need for placement away from normal paths of travel. (IFC 906.5) , 13: Fire extinguishers require monthly and yearly inspections. They must have a tag or label securely attached that indicates the month and year that the inspection was performed and shall identify the company or person performing the service. Every six years stored pressure extinguishers shall be emptied and subjected to the applicable recharge procedures. If the required monthly and yearly inspections of the fire extinguisher(s) are not accomplished or the inspection tag is not completed, a reputable fire extinguisher service company will be required to conduct these required surveys. (NFPA 10, 7.2, 7.3) 14: The total number of fire extinguishers required for a light hazard occupancy with Class A fire hazards is calculated at one extinguisher for each 3,000 sq. ft. of area. The extinguisher(s) should be of the "all purpose" (2A, 10 B:C) dry chemical type. The travel distance to any extinguisher must be 75' or less. (IFC 906.3) (NFPA 10, 5.4) 15: Maintain fire extinguisher coverage throughout. 16: Egress doors shall be readily openable from the egress side without the use of a key or special knowledge or effort. (IFC 1008.1.8.3 subsection 2.2) 17: Dead bolts are not allowed on auxiliary exit doors unless the dead bolt is automatically retracted when the door handle is engaged from inside the tenant space. (IFC Chapter 10) 18: Exit hardware and marking shall meet the requirements of the International Fire Code. (IFC Chapter 10) 19: Door handles, pulls, latches, locks and other operating devices on doors required to be accessible by Chapter 11 of the International Building Code shall not require tight grasping, tight pinching or twisting of the wrist to operate. (IFC 1008.1.9.1) 20: Aisles and aisle access ways serving as a portion of the exit access in the means of egress system shall comply with the requirements of this section. Aisles or aisle access ways shall be provided from all occupied portions of the exit access which contain seats, tables, furnishings, displays and similar fixtures or equipment. The required width of aisles shall be unobstructed. (IFC 1017.1) 24: Fire protection systems shall be maintained in accordance with the original installation standards for that system. Required systems shall be extended, altered or augmented as necessary to maintain and continue protection whenever the building is altered, remodeled or added to. Alterations to fire protection systems shall be done in accordance with applicable standards. (IFC 901.4) 22: Sprinklers shall be installed under fixed obstructions over 4 feet (1.2 m) wide. (NFPA 13-8.6.5.3.3) 21: All new sprinkler systems and all modifications to existing sprinkler systems shall have fire department review and approval of drawings prior to installation or modification. New sprinkler systems and all modifications to sprinkler systems involving more than 50 heads shall have the written approval of Factory Mutual or any fire protection engineer licensed by the State of Washington and approved by the Fire Marshal prior to submittal to the Tukwila Fire Prevention Bureau. No sprinkler work shall commence without approved drawings. (City Ordinance No. 2436). � 26: Maintain fire alarm system audible/visual notification. Addition/relocation of walls or partitions may require relocation and/or addition of audible/visual notification devices. (City Ordinance #2437) 27: An electrical permit from the City of Tukwila Building Department Permit Center (206-431-3670) is required for this project. 25: All new fire alarm systems or modifications to existing systems shall have the written approval of The Tukwila Fire Prevention Bureau. No work shall commence until a fire department permit has been obtained. (City Ordinance #2437) (IFC 901.2) 23: Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (City Ordinances #2436 and #2437) 28: Any overlooked hazardous condition and/or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. 29: These plans were reviewed by Inspector 511. If you have any questions, please call Tukwila Fire Prevention Bureau at (206)575-4407. PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 1700 BUILDING FINAL** 1400 FIRE FINAL 0409 FRAMING 0406 SUSPENDED CEILING YJ ILA h, �J� qs 4 "y. o �, z J � �s T 2 1908 ' CITY OF TUKI ,A Con:inunity Development Department Public Works Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.TukwilaWA. � Building Per..r►..�-No. t� ��p � � 1�� Project No. Date Applicarion Accepted: �� � (.V '�11� Date Application E�ires: ( Z� 7,(!' � lD use CONSTRUCTION PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **Please Print** SITE LOCATION King Co Assessor's Tax No.: 352304-9102 site Address: 1131 Andover Park West Suite Number: 1131 Floor: Tenant Name: Kenwood Manufacturing InC. New Tenant: ❑.....Yes 0..No PROPERTY OWNER Name: prologis Address: 12�20 Gateway Drive Suite 110 City: Tukwila state: wa zip: 98168 CONTACT PERSON — person receiving all project cotnmunication Name: Kate Molleson Address: 311 First Avenue South City: Seattle 5��� Wa Z'p� 98104 Phone: �206) 324-4800 Fa"' Emai1: kate.molleson�a jacksonmain.com GENERAL CONTRACTOR INFORMATION Company Name: Address: City: State: Zip: Phone: Fax: Contr Reg No.: Exp Date: Tukwila Business License No.: H:�Applieations�Forms-Applications On L'me�201 I Applicatans�Permit Applicetion Revised - 8-9-1 l.docx Reviud: August 201 I � bh ARCHITECT OF RECORD Company Name: JaCkson � Main Architecture, P.S. Architect Name: Gregg Percich Address: 311 First Avenue South City: Seattle State: wa zip: 98104 Phone: �206) 324-4800 Fa". Email: �.egg.percich@jacksonmain.com ENGINEER OF RECORD Company Name: Engineer Name: Address: City: � State: Zip: Phone: Fax: Email: LENDER/BOND ISSUED (required for projects $5,000 or greater per RCW 19.27.095) Name: Address: City: State: Zip: Page 1 of 4 BUILDING PERMIT INFORMATIQ Valuation of Project (contractor's bid price): $ 40,000 Existing Building Valuation: $ 5,770,1�0 Describe the scope of work (please provide detailed information): Tenant improvement within an existing o�ce area. Remove an existing closet to provide a new break room. no exterior work this permit. Will there be new rack storage? ❑.....Yes �.. No If yes, a separate permit and plan submittal will be required. Provide All Building Areas in Square Footage Below Addition to Type of Type of Existing Construcrion per Occupancy per Existin Interior Remodel Structure New IBC IBC 1� Floor $$,440 150 0 0 VB S-1, B 2 Floor 3 Floor Floors Uuu Basement Accessory Structure* Attached Garage Detached Garage Attached Carport Detached Carport Covered Deck Uncovered Deck PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 incHes and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Pazking Stalls Provided: Standard: 46 Compact: Handicap: 2 Will there be a change in use? ❑....... Yes FIRE PROTECTION/HAZARDOUS MATERIALS: �....... No If "yes", m....... Sprinklers 0....... Automatic Fire Alarm ❑.......None ❑.......Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑....... Yes �.......No Ij "yes', attach list of materials and storage locations on a separate 8-1/2 " x 11 " paper including quantities and Material Safety Data Sheets. SEPTIC SYSTEM ❑....... On-site Septic System — For on-site septic system, provide 2 copies of a current septic design approved by King County Health Department. H:�Applications�Formc-Applieations On Line�201 ] Applicetions�Permit Applicatan Reviud - 8-9-1 l.docz xe�ua: n„�s� zm i Page 2 of 4 bh PUBLIC WORKS PERMIT INFO ATION — 206-433-0179 � Scope of Work (please provide detailed information): Call before you Dig: 811 Please refer to Public Works Bulletin #1 for fees and estimate sheet. Water District ❑ ...Tukwila ❑ ... Water District #125 ❑ .. Highline ❑ ...Water Availability Provided Sewer District ❑ ...Tukwila ❑ ... Valley View ❑ .. Renton ❑...Sewer Use Certificate ❑... Sewer Availability Provided ❑ .. Renton ❑ .. Seattle SepHc Svstem• ❑ On-site Septic System — For on-site septic system, provide 2 wpies of a current septic design approved by King County Health Deparhnent. Submitted with Annlication (mark boxes which applv): ❑...Civil Plans (Maximum Paper Size — 22" x 34") ❑...Technical Information Report (Storm Drainage) ❑.. Geotechnical Report ❑...Traffic Impact Analysis ❑ ...Bond ❑ .. Insurance ❑ .. Easement(s) ❑ .. Maintenance Agreement(s) ❑ ...Hold Hannless — (SAO) ❑ ...Hold Hannless — (ROV� Proposed Activities (mark boxes t6at anplvl: ❑...Right-of-way Use - Nonprofit for less than 72 hours ❑.. Right-of-way Use - Profit for less than 72 hours ❑...Right-of-way Use - No Disturbance ❑.. Right-of-way Use — Potential Disturbance ❑ ...Construction/Excavation/Fill - Right-of-way ❑ Non Right-of-way ❑ ❑ ...Total Cut cubic yards ❑ ...Total Fill cubic yards ❑ ...Sanitary Side Sewer ❑ ...Cap or Remove Utilities ❑ ...Frontage Improvements ❑ ...Traffic Control ❑ ...Backflow Prevention - Fire Protection Irrigation Domestic Water ❑ .. Work in Flood Zone ❑ .. Storm Drainage ❑ .. Abandon Septic Tank ❑ .. Curb Cut ❑ .. Pavement Cut ❑ .. Looped Fue Line _>, >> >> ❑ ...Permanent Water Meter Size... " WO # ❑ ...Temporary Water Meter Size .. " WO # ❑ ...Water Only Meter Size............ " WO # ❑ ...Sewer Main Extension .............Public ❑ Private ❑ ❑ ...Water Main Extension .............Public ❑ Private ❑ FINANCE INFORMATION Fire Line Size at Property Line _ ❑ ...Water ❑ ...Sewer Monthlv Service Billing to: ❑ .. Grease Interceptor ❑ .. Channelization ❑ .. Trench Excavation ❑ .. Utility Undergrounding ❑...Deduct Water Meter Size Number of Public Fire Hydrant(s) ❑ ...Sewage Treatment Name: Day Telephone: Mailing Address: ' CiTy State Zip Water Meter Refund/Billine: Name: Day Telephone: Mailing Address: City Stete Zip H:Wpplieations\Formc-Applieations On L'me�2011 Applioations�Permrt Applieetion Revised - 8-9-] l.docz Re�ua: ao�n zoi i Page 3 of4 bh PERMIT APPLICATION NOTES —'�� �,�� Vatue of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of applicarion shall expire by limitation. The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). I HEREBY CER'TIFY THAT I HAVE READ AND EXAMINED THIS APPLICATTON AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERNRY BY THE LAWS OF Ti� STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING Print Name: Kate Molleson AGENT: Date: 06/20/2016 Day Telephone: �206) 324-4$00 Mailing Address: 311 First Avenue South Seattle WA 98104 City State Zip H:�Applicetions�Fornts-Applications On L'me�201 ] Applications\Permd Application Revised - 8-9-] l.docz Revised: Augus(2011 Page 4 of 4 Date Paid: Tuesday, August 16, 2016 Paid By: JURVAKAINEN COMPANY Pay Method: CREDIT CARD 07733G Printed: Tuesday, August 16, 2016 11:43 AM 1 of 1 - ��SY57EM5 Date Paid: Monday, June 20, 2016 Paid By: JACKSON MAIN ARCHITECTURE Pay Method: CREDIT CARD 684573 Printed: Monday, June 20, 2016 1:58 PM 1 of 1 ��� SYS7EM5 , INSPECTION RECORD � Retain a copy with permit ��� _�i7� INSPECTION N0. PERMIT N0. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Bivd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 � � � Approved per applicable codes. a Corrections required prior to approval. COMMENTS: /� Inspector: Date: /,� /� � �/ � REINSPECTION FEE REQUIRED. Prior to next inspecUon, tee must be paid at 6300 5outhcenter Btvd., Suite 100. Call to schedule reinspection. / INSPECTION RECORD � Retain a copy with permit �� ���7� INSPECTION N0. PERMIT N0. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 � Apprvved per appticable codes. a Gorrections required prior to approval. � REtNSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedute reinspection. � INSPECTION NUMBER Project: Address: Suite #: J / �� Special Instructions: INSPECTION RECORD Retain a copy with permit �t�-:����� PERMIT NUMBERS CITY OF TUKWILA FIRE DEPARTMENT 206-575-4407 Type of Inspect�n: a o c� -T7� �-•� Contact Person: �w �Approved per applicable codes. Phone No.: COMMENTS: � .�.- ,� ai1� -- /��.5-P % � � Corrections required prior to approval. Needs Shift Inspection: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre-Fire: Permits: Occu anc T e: _,.,_ ___ _ . , Inspector: ,;� ��� 5 S Date: ��j� �� � Hrs.: /. � �i' � / / ' �$100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. Billing Address Attn: Address: Companv Name: State: Zlq: Word/Inspection Record Form.Doc 3/14/14 T.F.D. Form F.P. 113 INSPECTION RECORD 1 t� — c� i� b f Retain a copy with permit / -S-It�1 INSPECTION NUMBER PERMIT NUMBERS CITY OF TUKWILA FIRE DEPARTMENT 206-575-4407 Project: Type of Inspection: e.� �..� a �,G fZfG� . � t/P (j Address: Contact Person: Suite #: Jt3/ ��, Special Instructions: Phone No.: �Approved per applicable codes. � Corrections required prior to approval. COMMENTS: �� ,-'1 t r � �..J I � � Needs Shift Inspection: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre-Fire: Permits: Occu anc T e: Ins � I Date: Hrs.: �$100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. Billing Address Attn: Address: Companv Name: State: Zlp: Word/Inspection Record Form.Doc 3/14/14 T.F.D. Form F.P. 113 � • • • 2012 Washington State Energy Code Compliance Forms for Commercial Buildings including R2 8 R3 over 3 stories and all R1 Revised Jan 2014 Project Info Project Address Kenwood Manufacturing Inc. Date �����'��{'J16 Compliance 1131 Andover Park West For Buil� ; e eh �, forms do not �aWordto Tukwila,WA ��lr� � � ���� use. Applicant Name: �ackson � Main Architecture, P.S. Instructional and Applicant Address: 311 First Avenue South , Seattle WA 98104 calculating cells p�R M I T C E N T E R are write- Applicant Phone: p06.324.4800 Project Description ❑ New Building ❑ Addition ❑� Alteration ❑ Plans Included Q Lighting Power Density Calculations Q Total Building Performance Lighting Compliance Path (If Total Building Performance then only LGT-CHK is required.) Lighting Power Allowance Q Building Area Method Q Space-By-Space Method Method Selection required to r_ .._ _.,. enable LPA forms Interior Lighting System �ADE COMPLIANC Description ��pp�p�/Ei� Briefly describe lighting � �, �" AUG 12 2016 � system type and features. , � I \ 9% Additions and Change of Space Use (C101.4.3 & C101.4.4) BUfL ING DIVISIO ❑ Addition area or Change of Space Use area complies with all applicable provisions as stand alone project � � Addition area is combined with existing building lighting systems to demonstrate compliance with all applicable provisions per C101.4.3 Provide Building Area Method (LTG-INT-BLD) or Space-By-Space Method (LTG-INT-SPACE) Compliance Form. Document maximum allowed and proposed (including existing if applicable) lighting wattage ofAddition or Change of Use space. Provide applicable lighting controls per C405.2 and commissioning of /ighting controls per C405.13. Alterations, Renovations and Repairs (C101.4.3.1) ❑ 60% or more of luminaires in space replaced Provide Building Area Method (LTG-INT-BLD) or Space-By-Space Method (LTG-INT-SPACE) Compliance Form. Document maximum allowed wattage within the lighting retrofit space in Maximum Allowed Wattage table and proposed (including existing) lighting wattage in Proposed Wattage table. Retrofd and non-retrofit spaces shal/ be documented separately using multiple forms. � Less than 60% of luminaires in space replaced Provide a separate Space-By-Space Method (LTG-INT-SPACE) Compliance Form for this retrofrt area. Document existing total wattage within the lighting retrofit space in cell provided in the Maximum Allowed Wattage table. Document proposed (including existing) lighting wattage in the Proposed Wattage table. � Lamp and/or ballast replacement within existing luminaires only — existing total interior building wattage not increased � New wiring installed to serve added fixtures and/or fixtures relocated to new circuit Provide applicable manual lighting contro/s (C405.2.1), occupancy sensors (C405.2.2.2), daylight zone controls (C405.2.2.3), specific application contro/s (C405.2.3), and commissioning of lighting controls per C405.13 � New or moved lighting panel Provide all app/icab/e lighting contro/s as noted for New Wiring, automatic time switch controls (C405.2.2.1), and commissioning of lighfing controls per C405.13. � Space is reconfigured - luminaires unchanged or moved only Provide all applicable lighting contro/s as noted for New Wiring and commissioning of lighting contro/s per C405.13. ❑� No changes are being made to the interior lighting and space use not changed. � 2012 Washington State Energy Code Compliance Forms for Commerciai Buildings including R2 8� R3 over 3 stories and all R1 Revised Od2013 Project Info ProjectAddress ICerorood Manufacturing inc. D81@ 6/20/2016 Compliance forms 1131 Andover Park 9Peat For Building Department Use do not requlre a Tuxriia, wA password to use. q licant Name: Jackaon � Main Architecture, P.s. Instructional and PP calcu/ating cells are Applicant Address: sii First Avenue sounh, Seattle, WA 98104 write-protected. Applicant Phone: 2a6. s2a , aeoo Project Description ❑ New Building ❑ Addition ❑✓ Alteration ❑ Change of Occupancy/Conditioning Compliance Path Q Prescri c��e P � Component Performance � Total Building Performance Se/ection required to enable forms. Occupancy Group �Q Commercial � Group R- R2 & R3 over 3 stories and all R1 Selection required fo enable forms. Vertical Fenestration and Total Vertical Gross Exterior Skylight Area Calculation Fenestration Above Grade % Vertical If complying via the Prescriptive path, (rough opening) divided by Wall Area times 100 equals Fenestration enter va�ues tor vertical tenestration, X 100 — ; skylights,; ross walls and roof on this T — ENV-SU�worksheet. If complying via the Componenf Performance path, enfer � ' , Gross Exterior these values in the ENV-UA worksheef. Total Skylight • divided by Roof Area times 100 equals % Skylight These values auto-�ll from ENV-UA and ;- � are write-protected on ENV-SUM. � " _— X � QQ = � ' Vertical FerieStY'dtlOri 1iY'e1' Fenestretion Area Compliance Skylight Area Vertical Fenestration � 50% or more of the floor area is within a daylight zone per C402.3.1.1 Alternates � High Performance Fenestration U-factors and SHGC per C402.3.1.3 Compliance Method ❑ Skylight area 3% or greater, VT-0.40 or greater Single Story Spaces ❑ Skylight effective aperture 1% or greater, provide calculation Requiring Skylights ❑ Space eligible for exception " Requires a minimum of 50% of floor area fo be within a skylight day/ight zone for spec�c space types. Refer to C402.3.2 for requirements. ❑ Project has semi-heated spaces as defined per C402.1.4 ❑ Appiying wall exception to semi-heated spaces 1. Semi-heated spaces may comp/y under Prescriptive or Component Performance compliance Semi-Heated Spaces path. 2. Semi-heated spaces shall be documented separate/y from other conditioned spaces — provide separate comp/iance forms for each conditioned space type. 3. Enve/ope elements separating semi-heated from other conditioned spaces shall comply with exterior therma/ envelope requirements. Q Walk-in Cooler ❑ Walk-in Freezer ❑ Refrigerated Warehouse Cooler ❑ Refrigerated Warehouse Freezer Refrigerated Spaces Refrigerafed spaces shall comply under the Prescriptive Path on/y. Compliance documentation for these areas may be combined with non-refrigerated areas in the ENV-PRESCRIPTIVE form. Refer to C402.5 and C402.6 for requirements. Project includes more than one occupancy type and/or level of space conditioning. Multiple Mixed Occupancy and/or compliance forms may be required. Select all that apply to scope of project: Space Conditioning ❑ Commercial ❑ R2 & R3 over 3 stories and all R1 ❑ Refrigerated Space y� Conditioned ❑ Semi-Heated ❑ Low Energy ' � `�� � � & R3 - 3 stories or less , �4� � 4 � i� �,y ��, � �h 'Low eraergy areas are exempt from all therma/ envelope provisions and compliance forms for � � ';� p these areas are nof required. Refer to C101.5.2 for exempfion. � No exterior work this c�ermit. All interior work this nermit within fullv conditioned buildinn envPlonP_ City of Tukwila Allan Ekberg, Mayor Public Works Department - Bob Giberson, Director June 22, 2016 Prologis 12720 Gateway Drive, Ste. #110 Tukwila, WA 98168 RE: Kenwood Manufacturing, Inc. Tenant Improvement 1131 Andover Park West Permit Number: D16-0170 To Whom It May Concern: In accordance with Washington State Department of Health guidelines for G�oup A Public Water Systems, Public Works has implemented a cross-connection control program to protect the public water system from contamination via cross-connection. The program requires elimination or controt of any cross-connection between the distribution system and a consumer's water system by the installation of an approved backflow device. The City has determined that the building at the above address has deficiencies on the domestic water service. A Reduced Pressure Principle Assembly (RPPA), previously called a Reduced Pressure Backflow Assembly (RPBA), shall be installed immediately downstream of the existing 3-inch permanent water meter. Installation at another location requires the Public Works Director's approval. The RPPA shall be installed in a Hot Box/Hot Rock or equal freeze protection enclosure anct�ored to a minimum 4" thick concrete pad. On your site plan, please show the property line(s), street name, North arrow, building location, existing permanent water meter and proposed RPPA. Specify size, manufacturer name and backflow model number. Submit RPPA cut sheet and circle the backflow to be installed. If you opt to install now, you will need to apply for a Public Works Type C Construction Permit and submit the permit application with (4) four sets of plans together with a construction cost estimate for the RPPA installation. For a Type C permit, Public Works collects a base application and plan review fee ($250.00 plus 2.5% of the construction cost for installation of the subject device) when the application or revision to this Tenant Improvement is submitted. An additional 2.5% of the construction cost for backflow installation will be assessed at the time of permit issuance. I ~ 6 r 6300 Bui(ding • 6300 Southcenter Baufevard Suite 100 • Tukwi(a, WA 98188 � 206-433-0179 Tukwila City Hatl • 6200 Southcenter Boulevard • Tukwi(a, WA 98188 • 206-433-1800 • Website: TukwilaWA.gov Prologis June 22, 2016 Page 2 If you opt to bond for the installation, you must provide the following to the Permit Center: 1) an original design and instal(ation estimate, 2) a bond for 150% of the design and installation cost, and 3) a letter stating your intent to instal( the backflow within 90 days. The Public Works Director will withhold issuance of the subject Tenant Improvement permit until the backflow permit application is received or bond is posted. I have enclosed Public Works Bulletins Al-2, and C5 to help you. If you have any questions, please call Mr. Mike Cusick, P.E., Public Works Senior Water and Sewer Engineer, at (206) 431-2441 or me at (206) 431-2440 or joanna.spencer@tukwilawa.gov. Six�cerely, � Joanna Spe er Development Engineer JS:Iw enclosures: Public Works Bulletins #Al-2, and CS Permit Application cc: D16-0170 File Kate Molleson (W:PW Eng/Other/Joanna Spencer/Letter Prologis 062216) Building Permit Form PERMIT NO PG16-0101 —� �Q �� of 2? � (�� 4� 100% u� Find � Next � 0 f; � Citv of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-438-9350 Web site: http://www.TukwilaWA.�ov PLUMBING/GAS PIPING PERMIT Parcel No: 3523049102 Permit Number: PG16-0101 Address: 1131 ANDOVER PARK W Issue Date: 8/5/2016 Permit Expires On: 2/1/2017 Project Name: KENWOOD MANUfACTURING Owner: Name: AMB PROPERTY CORP Address: 60 STATE ST STE 1200 C/O RE TA , BOSTON, WA, 2109 Contad Person: Name: Address: Contractor: Name: Address: License No: RUSSELL CAHILL 23313 208TH AVE SE , MAPLE VALLEY, WA, 98038 CAHILL PLUMBING AND HEATING INC 23313 208th AVE SE , MAPLE VALLEY, WA, 98038 CAHILPH942JC Phone: (206) 793-9277 Phone: (425) 532-1977 Expiretion Date: 12/1/2016 Lender: Name: Address: , , , DESCRIPTION Of WORK: INSTALL 1" RPBP INSIDE CLOSET SPACE WHERE WATER ENTERS BUILDING WATTS Series LF009 FOR PREMISE ISOLATION. Valuation of Work: $2,000.00 � Fees Collected: $168.68 Water District: TUKWILA Sewer District: TUKWILA Current Codes adopted by the City of Tukwila: International Building Code Edition: 2015 National Electrical Code: 2014 International Residential Code Edition: 2015 WA Cities Electrical Code: 2014 International Mechanical Code Edition: 2015 WAC 296-466: 2014 Uniform Plumbing Code Edition: 2015 WA State Energy Code: 2015 International Fuel Gas Code: 2015 Page 1 of 2 View Report http://trakapp/trakit9/DocumentViewer.aspx?&report=/Documents/PERMITS/Building P... 08/10/2016 City of Tukwila Allan Ekberg, Mayor Department of Com�nunity Development Jack Pace, Director June 30, 2016 KATE MOLLESON 311 FIRST AVE S SEATTLE, WA 98104 RE: Correction Letter # 1 DEVELOPMENT Permit Application Number D16-0170 KENWOOD MANUFACTURING INC - 1131 ANDOVER PARK W Dear KATE MOLLESON, This letter is to inform you of corrections that must be addressed before your development permit can be approved. All correction requests from each department must be addressed at the same time and reflected on your drawings. I have enclosed comments from the following departments: PW DEPARTMENT: Joanna Spencer at 206-431-2440 if you have questions regarding these comments. The cross-connection program requires elimination or backflow installation between the water distribution system and the consumer's water system. Pubiic Works has determined that the ] 131 Andover Pk. West building has deficiencies on the domestic water service. A Reduced Pressure Principle Assembly (RPPA) shall be installed immediately downstream of the existing 3-inch permanent water meter. Installation at another location requires the Public Works Director's approval. The RPPA shall be installed in a freeze protection enclosure anchored to a minimum 4" thick concrete pad. Separate letters were mailed to Prologis, property manager and to the building owner addressing this issue. The Public Works Director will withhold issuance of this TI permit until the backflow permit application is received or bond is posted. Piease address the comments above in an itemized format with applicable revised plans, specifications, and/or other documentation. The City requires that two 2 sets of revised plan pages, specifications and/or other documentation be resubmitted with the appropriate revision block. In order to better expedite your resubmittal, a'Revision Submittal Sheet' must accompany every resubmittal. I have enclosed one for your convenience. Corrections/revisions must be made in person and will not be accented through the mail or by a messenger service. If you have any questions, I can be reached at 206-431-3655. Sincerely, C �.__������ " . Bill Rambo Permit Technician File No. D16-0170 6300 Southcenter Boulevard Suite #100 � Tukwila WashinQton 98188 � Phone 206-431-3fi70 • Fcix 20h-4_31-3h�5 � - P�Ri��i' �OORD COP� . PLAN REVIEW/ROUTIl�TG SLIP PERMIT NUMBER: D 16-0170 DATE: 08/10/16 PROJECT NAME: KENWOOD MANUFACTURING SITE ADDRESS: 1311 ANDOVER PARK W Original Plan Submittal X Response to Correction Letter #�L DEPARTMENTS: Revision # before Permit Issued Revision # after Permit Issued Building Division � Fire Prevention ❑ Planning Division � I�`J r91�� �' '�� i ic Works Structural ❑ Permit Coordinator ❑ PRELIMINARY REVIEW: DaTE: 08/11/16 Not Applicable ❑ (no approval/review required) REVIEWER'S INITIALS: Structural Review Required � DATE: APPROVALS OR CORRECTIONS: DUE DATE: O9�Og�16 Approved � Approved with Conditions d Corrections Required ❑ (corrections entered in Reviews) Notation: REVIEWER'S INITIALS: Denied ❑ (ie: Zoning Issues) DATE: Permit Center Use Ofrly CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PVJ ❑ Staff Initials: 12/18/2013 P ORD COPY PLAN I /ROUTING SLIP PERMIT NUMBER: D 16-0170 DATE: 06/20/16 PROJECT NAME: KENWOOD MANUFACTURING INC SITE ADDRESS: 1131 ANDOVER PARK W X Original Plan Submittal Response to Correction Letter # Revision # Revision # before Permit Issued after Permit Issued DEPARTMENTS: w� � �,�UV� f0� � (� ��l �W� G � � 1 � 1.� (���� � �� BuiVdin Division Fire Prevent�on Plannin Division g g � �}e%s �Y1� (o• 2 ' l� Public Works Structural ❑ Permit Coordinator ❑ PRELIM.INARY REVIEW: DaTE: 06/21/16 Not Applicable ❑ (no approval/f•eview required) REVIEWER'S INITIALS: APPROVALS OR CORRECTIONS: Approved ❑ Corrections Required � (corrections ei�tered if� Reviews) Notation: Structural Review Required ❑ DATE: DUE DATE: 07�19I16 Approved with Conditions ❑ Denied ❑ (ie: Zoning Issues) REVIEWER'S INITIALS: DATE: Permit Ce�:ter Use Or:ly CORRECTION LETTER MAILED: y� � / ,�J Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW � Stafflnitials: ��� — iv�snois Joanna Spencer From: Todd Reedy Sent: Tuesday, June 21, 2016 8:34 AM To: Joanna Spencer Subject: RE: 1131 APW D16-0170 Good Morning Joanna, Regarding 1131 Andover Parl< West: -The 10" fireline DCDA is current on testing. -No irrigation connection. -No RPPA installed on the 3" domestic service. This service feeds several tenant spaces in this building. The only domestic backflow preventer in our database for this building is a 1" RPPA that was installed inside for address 1139 APW in 2015. Please let me know if you have any questions, Todd From: Joanna Spencer Sent: Monday,lune 20, 2016 4:51 PM To: Todd Reedy <Todd.Reedy@TukwilaWA.gov> Cc: David McPherson <David.McPherson@TukwilaWA.gov> Subject: 1131 APW D16-0170 Good Afternoon Todd, Are their backflows up to date? Joanna � City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Web site: http://w���r.Tuk��rilaWA.tr-ov REVISION SUBMITTAL Revision submitta[s must be sub`reitted in person at the Permit Center. Revisions will not be accepted tlirough the �nail, fax, etc. Date: � � � �i� Plan Check/Permit Number: �C� � O ��� ❑ Response to Incomplete Letter # � Response to Correction Letter # � ■ � ■ Revision # after Permit is Issued Revision requested by a City Building Inspector or Plans Examiner Deferred Submittal # Project Name: Project Address: 113 I ��� 4�lt�.o N� Contact Person: ����� 5i� ��' Phone Number: Summary o,f Revision: _ I �� �� �. � n � � � Sheet Number(s): "Cloud" or highlight all areas of revision inc[uding date of revision Received at the City of Tukwila Permit Center by: ��FK�,,ad � Entered in TRAKiT on �' � W:�Permit Center\Templates�Forms�Revision Submittal Formdoc Revised: August 2015 C P CONSTRUCTION SERVICES " T,C Home Fspanol Contaict: Safety & Health Wa3hington State Department oi �abor & I�dustries C P CONSTRUCTION SERVICES LLC Owner or tradesperson Princip�is JURVAKAINEN, RANDY ALLEN, PARTNER/MEMBER JURVAKAINEN, BRADLEY DEAN, PARTNER/MEMBER CASCADE PACIFIC PAINTING LLC, PARTNER/MEMBER JURVAKAINEN ENTERPRISES LLC, PARTNER/MEMBER JURVAKAINEN, JILL ELIZABETH, AGENT Doing business as C P CONSTRUCTION SERVICES LLC WA UBI No. 602 844 469 Parent company JURVAKAINEN COMPANY LLC License Page 1 of 2 Search L&I �.._____—� �. �= r3'r� �:;""�_ A-'J., Index i-felp nf}- Lt�I Claims & Insurance Workplace Rights Trades & Licensing 2631 77th Dr NE LAKE STEVENS, WA 98258 425-345-0830 SNOHOMISH County Business type Limited Liability Company Governing persons BRADLEY DEAN JURVAKAINEN ENTERPRISES LLC JURVAKAINEN; PAINTING LLC CASCADE PACIFIC; RANDY ALLEN JURVAKAINEN; Verify the contractor's active registration / license / certification (depending on trade) and any past violations. Construction Contractor Active. Meets current requirements. License specialties GENERAL License no. CPCONPC920NH Effective — expiration 08/08/2008-11/14/2016 Bond _.......... DEVELOPERS SURETY & INDEM CO Bond account no. 794694C Received by L&I 08/08/2008 Insurance ............. West American Ins Co Palicy no. $12,000.00 Effective date 07/02/2008 Expiration date Until Canceled $1,000,000.00 https:Usecure.lni.wa.gov/verify/Detail.aspx?UBI=602844469&LIC=CPCONPC920NH&SAW= 8/16/2016 � %�'��rz� { i � �' � ��:`is ; i r r � . -.R. n. . �.., .�. . � ��j t � , � ' 7 � t i � .,. t h M : .. . � . , ..,... , a� „ ..p ., � �.,. r :�.�.,�. a�t; ' , .,, c,.,� .+� e � ; �. . ..� ' .. t�, �� � �,. :•.�Y+.. 'i��.3 ..,'«�. �v. '":""��r16,:F 1 . .. ...:. f6 "�'.. , .,, .,,r, n'; i i �. i - � � . e .. � r . t d . o-. v. m.. a . , . , 4 � M . n . . .U��., . wt1 �l�yt i„P � . �r . . . t� t � . , y#.. "n .., : �� .9 ...,. . . ,Jt, �'I., ,S i".h.k �,. i7a��YY�YS ��+k�4S'�9n�bf� S�N•. ..+F^w ".nS,.,.. r'�`?'t„ab.,.,�k' .r��4..,4.ua,?:.,Gxlko-�ai.N. �. ..,.. .. .r.>,. . ,,..e . .., , . „ .,.v :'.x.,,:,.,. ' atw"�$5'�` t .i.t�^ �i'� � �+.. %� a* . io ,.i. °�?i", t,,,a.... .�.: .: ;, . :, ;,.. r,,,,,,: ,,, , . , r ., �� �� '7dw'�w,' ��aY9g, . , �' . �.��' . . . '.. 9a"�i.�+r�';�:'d��. r�... ;�. 7V.�,;.;. �wk�"x ,aP�. �'��.a.�'.sS���, .�,�., y�h ., .; .m ..S�f�J,�+,��:� � �,.. �. �,'^,±�4d�+" ;�. i� , .;t�t- : c"�. , '�... �s � .�", � � <� � � .. , "�, Y , �" ,„, J '� c .. � f< r <<; � � "�. � `� � . E a�� c � �; „ � � $4 �t� , �, �, � a �, , tt i a � � � "w�v ,w, r,� 4, � , a �<� "� n �b,rx% + .<, v, , ` 4 i , � > . , � �r � , ,T s � �, � : ,£�S : � ; . � � ." . �,,"�ti . .i"� 9. .. �, �' ., .d. � �f�,�� .�. ,fi: , ..t<.. .� � �s k .r �f � N,, e t a, d. a ,� � � .. � i � i'�. � @a r , . � . � . . „ ,� . . n. 7 {,, :, . ,F � � � : � ,. ",'� � <,a; ���� � ' n�, ,; ;� ,�a ;. . � ..: ,� ri �. ,,. �,.� �; ,n , �:. a 1 n. ��, . '„ �, . t", ���,.. � � �q` �:. � .r. ,; k �': d 1 > .. �.�.:, .. � �,� .� �.. .o � .��;,3 ,,; ...�a ,>< <, , t� ,i3 �a.....+...�. . '� � x l. „� ,� '� � , , ., , ; . � # , a�.. . ., , ,. >; c: � �f� � ��. yn,� �e �� �e � � ,o a. <.:.,,, , �.,:.:,, �, <. �- ,,. s,,. , ,.,,, , ,,;,:r � ..... ,�. ... :.B ,. .. �a �:� �. � L�,�. a�. ., a , a ��. .. �� :�, ,� ��3�, �� „ �£,�.e,<�, st,,.i:,.. . <,,,: , , ', rr,: a��. �a �. -, .,. �; a � .a '�s, ,,c. y ,. ,. E�. ±, :a �u� ., . a +�, '�� ;,�W , c, �if r. 4,, � ¢�. „` s � :,�k .y „e:. � ,. ; ,- , ;�,.s� ':�, r , . s�. ,^. ':R< �,. „ d u. o. 'x, u� ,5 :, s .: �,. f� � � u '. v. m.i` �a� �Ag.,, .. J .. f�� 5C 1 2 . �: � � ,: �7: �:. .e 2� �� ' ��i� � , ! � '� �vx. . �Y n,g t � u,� �� ., ,. � , .., � � n �. �.3 ,.w Y ��';.. � �.. .�`I.,hY �1t1 i',..;k ..,.,,,. r' ..,..: S ,�,,,.: .., .�i, . . n y . :. � x � ,�, r k� ,. � � �.. �,. U' Y �( e�. "� ..�� � . .., . . .. . .. . , . r£.��� , .. c , . ..., Y ",.,. . , . ,...,, � . ..e � . a,�.. 1 i? .,,. ..�. . „� 'i. � �. � � ..,..n��. t i >> ,.a . + .,,, �M1� r+ .. 'Y k� �, ��i .. ,.,.��. ,. , i .,. .� � .,<<,,.a ..r, x.. t. „..., ,� . i .. . � .. ,. ,, a. �,s .F .?... ..,.�� t . .� a �.. i. ,v� ,.,� .. .�,.. ...., , , , „ ,_... �c, �h , . . � �.,: � �k 3 �, ,,. � . � .§+ Y, . ¢ .. v, .. K� ,� , o. .. a.. � ����.r,..�s '�b �"8^ . •�,, i ��� , �r .., .u.,... .. ��'1, .�t.a .....kYa �.,r...�.., ...,U:. � Yv,,,,,; ..,. . � U , � � �'� .d 2+, �, d ,t � ti . .savd;7 , t a �� . J 1 .. >'�. �'kYA�1'B . S4 a»u�i trY tl.�' dv� �'*" � � s ..Ak^ , a . , N�.S'S '.w a ,q, �i' � � : o.�.�k �� .ar,Po..E.P „ @. ,.. �.:. .�" �� ;'�; ,,, ..�. .. ..... ... ..... r:. µ, �' .t . o,a. >'dw, �:'�. C.4N. t t „ �: �. .: , VS . � �: � . �' k�� �'b i {. , � ... �.., . �� ''� � ,.. a ;` ,. < <. �.. .+. ¢ .k�; ,a� �'S� � , �., n . f. ��.:v ��t ,,.. .� .�..7<. r::,f , �,.. ,,..,, . , .,.,,: .:�"t��X� � a. .� � , Fc ,� .e. .,, ., �. I� ,r 1 .Y '�� .� i� �a�� �,.,.�. ,,. , z,,.,. ,. ..,.. �...,.. ix� i�`� � i, a £ �s. r a'. ., �. ,x x� . ,. ; .' � ,. � ..i �4iA?�+,� �, �'� , � ,: : , o- .:t"'�'.. .. . .�.. >, . „ ,. � t. ..,u° � �.� � � "°'i� u£ . � k ,..�. '� .V .. ..�. F 9 � r � �3, ,.„,.. , .sr. ,,,« , o.v �.�.: ,:u, ,�., . ",�m''a . , "'�' . , � . . ..R. r� ;z ,r � ;: ��, s.' :� s. r ,' .' ;. zk i � �1 ; �' . .:. . e� ,,..,. , ., e„ , , ,, .. ..M ,s. :a� : n � �� x z, ,. 4 ��. d C . . ..��.� �„ .,,., .„ � .,. ; ���� A . ,,..; , .. . s�, a .,.:. ,.¢,<: , ��. < n&, a t § .> ��s ���- � :, Y'.. � ., .. � ,t : , .. ; �'�.=..tt , i. .,r ,"�„ �:r�. t. :', , ., �f t. � ,� ,r �. �� Y .. 4 Y„�s:S,�?P � ,,,,3£tha!@t�2S: �f� ,. � �'i . '�3'.5;>. s.., .'.{. ,..¢ ,�>.� ...� �S , �� ¢ �, „ a � �. . o-� � � �„ � > � � , , � � , . � � � ; � , � #, ,,,:. � � F�:, ti „�:.$ : ° _ . ;, � , � . , , � . � ., � '�� � �, � n � �. , , � r ;,`.� � � � , �„, 7 ,,, ,. � , , , ,, . ., .,; ; a ; �, � ?�, ,. � , . � � �,. � �, ' a ,. � � � � ,�. ,>.. s rt �r, ,r,, tw � � �, � e, A k � � . � A � . , a , r r � � �. ,,,� , ,, , 1 � � x � � � � s a, � �.,K: „A �, � � � , - :_ , �,� 1., #. .., .i.. � � .m "E, .� u' v. � .� �a. 1, f �t ��, ,� �+5.,., �. ,'� � ;�. � !� .: .? h � ,�. R -a. 1. ,.. ^� v� a �,. :: ��. „ r. �, �r� , t�'z� , .,..:,< rrt.:;�. „> ,,,. ,�, . ,t,. .g :; �, �.o . S� '�,. , w t. s , .�< f,.ti �a �, �. ,c. ��C @, ... ,.. ,... ��.o--, .� . a. ��. .,. „ ,. ��� ,�:,, ;� ... � k, .�'3 ,, 9;� , a, �. ,`"T .., r ..,, ..�. ,v. .�:�J ,„.., ..,, � . a. , . � .,. R ., , u t ��; . ., x. .,.�.. .,,. ,., . ..<.., z, � , � � w� � � � �, � �. x. , A 6r a. . . r, . � , .-3 �. .a.� Y` '� � .,. � . � , < ., , � .y,%�& ..... ., .. n.en: n .,., „i> i; � �a t .- � a , f , , , . � v u � ,., . � � , „ �, � t � r . � „ c . ¢ u t 4 � r � o ., , � , , v ; r � a �. , � �, � �.r-.. ,. . x� .t .. ., rf. '. �. v r. ,. .�, ., .;.;.. .� �. ,� .�. "�. . , n , .... n � >.: � „ ,... �, . .� m . 1`„ ,. � , . , �, . , . .:, ... ..,, �,.: , .. ,. .. �� ,-. .�. ., �. , . d . .:. .d. �. , k � ..s. , ..,. ��.. a �, . '� t ��. .., �, v...., �. , . �� � � . .. � � . r .x� i+ � u. .&�', ,�. �. . a .7 �"' , -,. . > ..: , "� , 4 , Y. . , w � . , � �: � x �� � � � � � .r� � a �v � �. t � �s °� z �4 1 ,,, :� � ��� �,,,a� �,t.. ,� s�.,,. �'. a. � �;. �a,� � �..sa� n,. .a`�,�i„at��i s!� ,k � � �. � eYkarz� � � �, � s'� .s�m. �a, �� �t�m;. �i,�.,r.� , . �; . ,. v,��`"�.�,� , � �„, '�,,��' „�� m� �S ��� � �? `°�r$ � 3 �x tr? r �'�' ��: .ti, .�Rr d.s��r�. a � � .m� ..�.. �h,n .�� . � ��� �,� �i�,�r � �f��. x si2 , ; �' �;. 4`� J .i � � �mYt .r�t�,b 3� 4' t p i �s a; � it "�����q�{z �s i ; g �t ? �� �y�' t a" .� r , �SO��tl��`Y� � µ.� P AJ t3 ��� A 4� . 5 f , D 4�d �+ f�:� �Y j .r �. ��� � � �� � � r�, °'h e r s k a� 1 2� s' � � t�l �, � r g. � � r ., � ..� a�. • . � � . . f . � }:�� �.� ���� �� ���.',p�re�:iu�4:�. ..�'�'�r`%.Sw a��£r�`� ,`+.� .,s�, c,' G . � � . ����, , • � � � i � � �� � � � � � �� � , •, ' ��/ � � �� � � � � � � ��� � . � � � � � • • � � � � � � i � � � • � � � � � � � • • , � � � � � � � •• •' � � • ••� �! � � I • � •�' �; . � � � � ���' : �• � : � 1 " r��'�a,��� 'a��:�� � t��a � r $t 41�� . �, �, � � � I • • �' � � � � � � ' � ��t'39v'��z tr '" � t ; t' 1 ������a� �4 sa� r� '�� � i � �� f � r � � ': •: �';�.�P.�,�#wa�.,t F h �4„a:, r,,.� r, �r� , . � :, 7� rw � , �' • •� � •'� , ;� � � • � • 1 11 � � � vKm�.,�zw� .;�s���,�:�, F���.�sos�, .<�<,�>-.��n ' r • - 5. COMPLIANCE CARD TO BE POSTED VERIFYING INSULATION INSTALLED IN WALL, CEILINGS ANDS FLOORS (IF REQUIRED). POR SW 1/4 OF SE 1/4 OF SEC 26-23-4 & OF NW 1/4 OF NE 114 OF SEC 35-23-4 - BEG SE COR OF SW 114 OF SE 1/4 6. ALL WOOD COMING IN CONTACT W! CONCRETE. SHALL BE PRESSURE TREATED (DECAY RESISTANT). OF SEC 26-23-4 TH N 01-47-29 E 140.76 FT TH N 87-55-02 W 740.67 FT TH S 01-51-03 W 13 FT TO TPOB TH CONTG 7. IF ANY ERRORS, OMISSIONS OR INCONSISTENCIES APPEAR IN THE DRAWINGS, SPECIFICATIONS OR S 01-51-03 W 809 FT TH N 87-55-02 W 219.05 FT TH N 01-51-03 E 780.50 FT TH N 63-25-19 E 55.67 FT TH ALG L E OWNER OR ARCHITECT IN WRITING OF SUCH DI T 68.32 FT THRU C/A OF 111-50-19 TAP OTHER DOCUMENTS, THE CONTRACTOR SHA L NOTIFY TH CURVE TO LFT THE CENTER BEARING N 63-25-19 E RAD 35 FT ARC S OMISSIONS, ERRORS, OR INCONSISTENCIES BEFORE PROCEEDING WITH THE WORK, OR ACCEPT FULL OF REV CURVE TH ALG CURVE TO RGT THE CENTER BEARING S 48-25-00 E RAD 20 FT ARC DIST 17.63 FT THRU RESPONSIBILITY FOR COSTS TO RECTIFY SAME. C/A 50-29-58 TH S 87-55-02 E 96.94 FT TO TPOB 8. TYPICAL DETAILS OR BUILDING STANDARDS SHALL APPLY WHERE NO SPECIFIC DETAILS ARE �IVEN. 9. ALL DIMENSIONS ARE MEASURED TO OUTSIDE FACE OF FRAMING 10. ALL DIMENSIONS SHALL TAKE PRECEDENCE OVER SCALE SHOWN ON PLANS, ELEVATIONS, SECTIONS AND 11. ALL EIX T DOORS TO BE OPERABLE FROM INSIDE THE BUILDING WITHOUT KEYS OR SPECIAL KNOWLEDGE. � U I L D I 1�i �J � R E�S 16. MANUALLY OPERATED FLUSH BOLTS ARE NOT PERMITTED AND NO MORE THAN ONE OPERATION FOR THE UNLATCHING IS ALLOWED, 17. FIRE EXTINGUISHERS SHALL BE PROVIDED PER NFPA #10, OR REQUIREMENTS OF LOCAL FIRE OFFICIALS. OVERALL BUILDING AREAS: INTERNATIONAL BUILDING CODE 1 S. ALL EQUALS TO BE SUBMITTED TO ARCHITECT FOR APPROVAL PRIOR TO CONSTRUCTION. EXTERIOR FOOTPRINT FULL BUILDING 88,440 SF 19. BIDDER DESIGN WORK TO BE APPROVED BY OWNER & ARCHITECT PRIOR TO CONSTRUCTION. TENANTAREA THIS PERMIT- 17,639 SF WAREHOUSE AREA (NOT IN SCOPE) - 15,586 SF. OFFICE AREA - 2,053 SF � �� I ��� �� AREA OF WORK 150 SF SUBJECT SITE i � � -�. _ ._--, �CCU�ANT LOADS PER TABLE 1004.12 OF THE INTERNATIONAL BUILDING CODE TENANT SPACE WAREHOUSE: 15,586 SF @ 500 SF / OCCUPANT OCCUPANT LOAD = 32 OFFICE: 2,053 SF @ 100 SF I OCCUPANT OCCUPANT LOAD = 21 TOTAL OCCUPANT LOAD = 53 TOTAL EXITS REQUIRcD = 2 TOTAL EXITS PROVIDED = 2 D�WI��G INDE� ARCHITECTURAL A0,1 ' COUEi� SHEET & BUILDING PLAN A1A ENLARGEDPLANS A1.1 DETAILS & CUSTOMER FINISH STANDARDS TAX PARCEL NUMBER - 352304-9102 PROJECT ADDRESS - 1131 ANDOVER PARK WEST TUKWILA, WASHINGTON 98188 GOVERNING BUILDING CODE - 2012 INTERNATIONAL BUILDING CODE WI WASHINGTON AMENDMENTS GOVERNING ZONING CODE - TUKWILA ZONING CODE SITE STATISTICS ZONE - EXISTING SITE AREA - EXISTING ALLOWABLE LOT COVERAGE - EXISTING REQUIRED BUILDING SETBACKS- FRONT - EXISTING SIDE (INTERIOR) - EXISTING SIDE (STREET) - EXISTING REAR - EXISTING ALLOWABLE FAR - EXISTING ACTUAL FAR - EXISTING BUILDING STATISTICS ALLOWABLE HEIGHT - EXISTING ACTUAL HEIGHT - EXISTING NO CHANGE CONSTRUCTION TYPE - V-B SPRINKLED OCCUPANCY TYPE - B, S-1 PROJECT TEAM OWNERS: ARCHITECT: � PROLOGIS JACKSON ( MAIN ARGHITECTURE, P.S. 12720 GATEWAY DR, SUITE 110 311 FIRST AVENUE SOUTH TUKWILA, WA 98168 SEATTLE, WA 98104 206.414.7600 206.324.4800 CONTRACTOR: TO BE DETERMINED BY OWNER S E PARAT E S lJ B Ni i TTAL.S CONTRACTOR TO SUBMIT FOR AND OBTAIN PERMITS FOR ALL SEPARATE WORK INCLUDING; ELECTRICAL PLUMBING MECHANICAL FIRE SPRINKLERS ANDOVER PARK WEST ni��r� vi vvviv� i i �i� � �ivvii �. SUBTOTAL- 1 FIXTURE I 25 OCC. 0.84 NEW 3-112" 20 GA MTL STUD WALL @ 24" OC WI e" TYPE WAREHOUSE (S) - 15,586 SF/ 500 SF PER OCC.= 32 OCC "X" GWB EACH SIDE. fINISH PER BUILDING STANDARD, SUBTOTAL- 1 FIXTURE / 100 OCC: .32 57ts NEW 3'-0" X 7'-0" SOLID CORE CLEAR FINISH BIRCH DOOR REGISTERED TOTAL FIXTURES REQUIRED - 1.16 (.58 F/ .58 M) O AND "TIMELY" FRAME PER FINISH STANDARDS. PASSAGE CHITECT � SET, LEVER HANDLES, 3 HINGES, 3 SILENCERS PER FINISH STANDARDS, DOOR CLOSER WHE EQUIRED �%"'r-. FIXTURES (PROVIDED)- 1 FI 1 M PER STANDARDS. OBER A. KROESE STATE OF WASHINGTON ����� �. �DI� o EN E RGY C 0 D E� E Q. RI�.� ���i�w �q�r���9 i� �ubject t4 errors and or�i�sion�. � �������1 �f �c�nskru��io� dc��ments d��s �aa� �tctho��i�e GOVERNING ENERGY CODE: 2012 WASHINGTON ENERGY CODE ��� ��Q�����'� �fi `��� �d�P��� ��� ��' �t'C�It1aCIC�3. R��pj� COMPONENT PATH Qf ��pPi�V�Q +�'"��It� C0�3�► atl� %(3ildl��Lii'1 '� acknowiedged: Jackson � Main Architecture BUILDING SPACE TYPE HEAT IS "OTHER" (ALL OTHERS INCLUDING HEAT PUMPS AND �1 � �_ VARIABLE AIR VOLUME.) ELECTRIC RESISTANCE HEATING NOT ALLOWED. \��� O�� 311 First Avenue S: V v Q�� Seattle, Washington 98104 REQUIRED INSULATION VALUES FOR CONDITIONED SPACES - i 206.324.4800 � e-mail: gregg.percich@jacksonmain.com CLIMATE ZONE 1 X DETAIL � ROOF OVER CEILING TILES - R-49 BUILDING ROOF (NO ATTIC) EXISTING OPAQUE WALLS METAL FRAMING R-21 WI 1-112" R-8 CONT. RIGID WOOD FRAMING & OTHER EXISTING OPAQUE DOORS EXISTING NEW OPAQUE DOORS U- 0.40 FLOOR OVER UNCONDITIONED SPACE NIA SLAB-ON-GRADE EXISTING VERTICAL GLAZING EXISTING NEW VERTICAL GLAZING NIA LIGHTING: ALL AREAS ENCLOSED BY WALLS OR FULL HEIGHT PARTITIONS REQUIRED AT. LEAST ONE MANUAL CONTROL FOR LIGHTING. EACH AREA REQUIRED TO HAVE MANUAL CONTROLS SHALL ALSO HAVE A CONTROL TO REDUCE LIGHTING BY 50% IN A REASONABLE UNIFORM ILLUMINATION PATTERN. OR PROVIDE AN OCCUPANCY SENSOR DEVICE. OCCUPANCY SENSOR ARE REQUIRED IN: TRAINING ROOMS, CLASSROOMS, BREAK ROOMS, CONFERENCE ROOMS, PRIVATE OFFICES, RESTROOMS, JANITOR ROOMS, STORAGE ROOMS, WAREHOUSES, AND ANY ROOM 300 SQUARE FEET OR LESS ENCLOSED BY FULL HEIGHT WALLS. THE SENSORS SHALL TURN OFF THE LIGHT WITHIN 30 MINUTES OF ALL OCCUPANTS LEAVING THE SPACE. XX.X i� �U1LDI�G DI!/1SI0� " GRID LINES - COLUMN . x r�OOMNAME ROOMNAMEANDNUMBER S[��;��,?�� � ��A�'1, 101 r`Qt�°1�i�,� �'pR: �Moehan,ca! REVISION TAG �EI•��tr' � rcat Ql Pfumb�ng �Gas Piping X DOOR TAG •„ � . f Tu6cvvila , %3�.7d�,??�a`V� IaIV�S�C�i1i ILLUMINATED EXIT SIGN . ., , ,, �� ARROW INDICATES UIRECTION � ILLUMINATED EXIT SIGN WITH EGRESS PATH LIGHTIN� WITH BATTERY BACKUP SYSTEM e � EGRESS PATH LIGHTING ON BATTERY BACKUP SYSTEM � � � Tu!:�,��ila Bui�a�ny �, � ,...... - .,, �_...,;.� � n��v alan submittal ILD SCALE: 1132" =1'-0" These plans and specifications are the property of Jackson � Main Architeture, P.S. These documents may not be copied, reproduced, used or implemented in any way, in part or in whole, without the written consent of Jackson � Main Architecture, P.S. All common law rights of copyright are hereby specifically reserved. Print Record 06/17/2016 FOR OWNER REVIEW 06/20/2016 FORPERMIT Revision Record KENW�OD ANUFACTU�IN� UPLAND DISTRIBUl'ION CENTER 1131 ANDOVER PARK WEST TUKWILA , WASHINGTON 98188 I�EC�IVED CITY OF TUKWILA xF, � Jt�� 2 0 2Q16 ��" ���t f'ERMIT CENTER �� _ �� � , � � r �.� ��� y s � �� � d � � fi s�� �..� Yt � � �� � � � �� � � � � � � � � �� f �, � � � �, � � � �ti ���� r��� � � ��' � � r�,�§� ���� �� s}� ' "' �� � � �,��� „« E ��� �,��� sq� .. C'k . ..,.4, ( � 7 q � � 8 ,� 6i� � P I F iy 1 12720 Gateway DR Suite 110 Tukwila, WA 98168 Telephone: 206.414.7600 Facsimile: 206.414.7601 �� y���91P,eq�, 91 �q��,�� ," ��� + �! +'wt'I�!!��i'i'���V �fek��� f Y, � �' � Date Project No. 06120116 16008,06 Sheet Title COVERSHEET & BUILDING PLAN Sheet N o. � � ❑ Released for Construction Not Released for Construction 6 49'-0" 7 � 1 � � D E ��� . _ ... o. , �. T,. , , , , �� ` � � �� � � � ��� �� ��` � � � ���; i ` i, . " 1, r, �. / � : � � II 49'-0" � I� N z ; � j ��, , � �.. e, ,�` '•' � ,� � ; ��, �.. � + • � . �� � t� t� � I� 49'-0° �ACKso� � n�Ai � ARCHITECTURE �, �, � +��' I���'' � 4�,;�i ! ' ��i �' �; �,� ; i� � � �� „ I � 5719 REGISTERED � RCHITECT OBERT A. KROESE I STATE OF WASHINGTON Jackson � Main Architecture 311 First Avenue S. Seattle, Washington 98104 t 206.324.4800 e-mail: gregg.percich@jacksonmain,com , � � , r ''�� � �� These plans and specifications are the property of Jackson � Main Architeture, P.S. These documents may not be copied, reproduced, used or implemented in any way, in part or in whole, without the written consent of Jackson � Main Architecture, P,S. All common law rights of copyright are hereby specifically reserved. Print Record 06/17/2016 FOR OWNER REVIEW 06/20/2016 FOR PERMIT 1 1 � � � �� i,, � ti m„ip i , STORAGE � � � � 6 � ; '�I ' I I � � i'I � — — 105 D ' KEN OOD ANUFA�TURING OFFICE OFFICE UPLAND DISTRIBUTION CENTER 107 106 � 1131 ANDOVER PARK WEST TUKWILA , WASHINGTON 98188 CONFERENCE WAREHOUSE N 104 111 I Fi�CEIVED 11'-11��+1- CITY OF TUKWILA �o JU�17 U 2Q�6 A1.1 — — — — � PERNiIT CENTER = �, NEW WALLS FOR BREAK ROOM, �. i FINISH TO MATCH EXISTING PER w � BREAKROOM OFFICE �, c� � _ � � � CUSTOMER FINISH STANDARDS � � � � � � � � � � ��s��� --� 108 � 103 ,��Q F(� �� � I � " , RE.� ��y�p1.1PN � n�5� � OPEN OFFICE �O� �p�QV�a � � �' � �oo � � 12 2p16 N p�� 12720 Gateway DR ALIGN � SUIt2 � � � M � OFFICE . ���it� Tukwila, WA 98168 � � �02 • (;€,i.y ��,�y�vlslO� Telephone: 206.414.7600 ��y��,,,Ot� Facsimile: 206.414.7601 STORAGE Q 101 — — - � Date Project Na RESTROOM RESTROOM �16IZOI�6 �6OOU�O6 109 110 Sheet Titie ENLARGED PLANS � Sheet Na s E L E FL L G O � � � � � � ❑ Released for Constru�tion � SCALE: ��s° _ ��-o° Not Released for Construction � Customer Finish Standards _ Revised: March 3, 2014 DIVISION 1 GENERAL REQUIREMENTS 1,1 CODES: All construction shall comply with local, state and federal codes and regulations, including all ADA standards. 1.2 JOBSITE CONDITIONS: All contractors must verify existing job conditions prior to bfd. 1.3 DOCUMENT CONFLICTS: If there fs a conflict in the drawings, or between the written specs and the drawings, the contractor shall be responsible for lhe more expensive of the options. 1.4 CLOSE-OUT DOCUMENTS: Provide 0& M manuals and "as-buiit" drawings for all architectural, structural, plumbing, electrical, HVAC and fire protection work on two (2) CD's in pdf format, Provide one (1) hard copy and one electronic copy in pdf format of the stampad permit set of draw(ngs. The value of the close-out documents shall be 10% of the value of the respective work. 1.5 EXISTING STRUCTURE:. Nothing may be suspended from the 2x4 or 2x6 sub-purlins at the roof without the structural engineer's written permission except for warehouse lighting fixtures specified below. 1.6 EXISTING CONDITIONS: These finish standards shall be modified to match existing conditions with written approval from the Prologis Project / Property Manager 1.7 FLOOR MAINTENANCE: No vehicles except scissor lifts shall be allowed inside the building during construction without written permission irom the owner. All scissor lifts shall have non•marking tires and must be diapered to prevent marking and staining of the concrete floor. 1.8 SUPERVISION: The general contractor shall provide a highiy experienced jobsite superintendent, acceptable to the owner, to manage all the work during the course of construction. DIVISION 3 CONCRETE 3.1 PATCHING: Any removal and replacement of the concrete slab shall meet the requirements of the existing slab. Do not overcut comers when cutting the floor in warehouse areas. Use care when removing concrete to avoid damage to adjacent slabs to remain. Backfill and subgrade shall be compacted to 95% of maximum dry density determined in accordance with ASTM D-1557. Dowel the new concrete patch to the existing slab with 1!2" steel dowels, extending a minimum of 8". into slab at 18" o.c., secured with epoxy. Install two (2) #4 rebar horizontally in all plumbing trenches. Use 4,000 p.s.i. (at 28 days) concrete for the pour back. All trench patching in the warehouse area shall have a 1/8 inch radius edge and apply new concrete seal. Prior to pouring concrete, stone o t a 8 inch radius ed e. Install va or barrier ff ti awcut ed e with an abrasive brick to a r xima e 1/ the exis n s 9 Pp 9 P 9 there is exisUng vapor barrier. Sawcut control joints in new concrete to match existing, and install joint filler to match existing (Metrger McGuire MMSO or equivalent) DIVISION 4 METALS 4.1 BOLLARDS: Furnish and install two (2) 6" diameter, concrete filled, thin wail steel, pipe bollards extending 4'-0" A.F.F., set in 3'-0" of concrete at each grouping of electrical transformers and panels and at all sprinkler risers in all warehouse areas and other locations exposed to vehicular traffic. Paint new and existing bollards OSHA "Caution Yellow". Surface mounted bolt down bollards may be acceptable at low traffic areas (verify with Prologis Project / Property Manager). Surface mounted bollards shall be 4" diameter 4'-0" A.F.F. wfth a one foot square base plate and expansion anchored to the concrete floor with four (4) each'/z' expansion anchors. DIVISION 6 WOOD AND PLASTICS 6.1 CABINETS: Fumish and install a coffee bar and / or lunch room base cabinet. The base cabinet(s) shall be plastic laminate by Wilsonart or approved aqual in the manufacturer's standard color on all exposed horizontal and vertical surfaces, including open cabinet fnteriors, unless otherwise noted, Semi-exposed cabinet interiors and shelves shall be white melamine with .5mm PVC edge binding. Drawers shall be Grass 6036 Zargen System slides or approved equal. The hardware shall be 96mm wire pulis, 125deg. Blum concealed hinges or approved equal. The cabinet(s) shall be 6'-0" long minimum and 34" high. Each cabinet shall have one row of drawers over doors. The maximum depth for cabinet and countertop should be 24". 6.2 COUNTERTOPS: The countertops shall be plastic laminate.by Wilsonart or approved equal. The coffee bar tops shall have a 2" bull nosed front edge and top edge with a 4" splash and a radiused inside and outside comer at the backsplash, For SF Bay Area Market, install a solid surface countertop per finish spec provided by Prologis persannel. 6.3 LAVATORY COUNTERTOPS; All office toilet rooms with muitiple lavatories shall have vanities. The lavatories shall be installed in a plastic laminated countertop with 2" bull nosed front edge, a 4" backsplash and a radiused inside and outside comer at the backsplash. Single accommodation toilet rooms and muitiple accommodations toilet rooms serving the warehouse shall receive wail mounted lavatories, For SF Bay Area Market, fnstall a solid surface countertop per finish spec provided by Prologis personnel. 6.4 MILLWORK QUALITY: Architectural millwork and cabinetry shall be of a construction quality equal to that of the Architectural Woodwork Institute's (AWI) custom grade for flush overlay construction. MDF products shall be matle with binder containing no urea-formaldehyde. Wood glues used for fastening shall have a VOC content of 30 g!L or less when calculated according to 40 CFR 59, Subpart D(EPA Method 24). Multipurpose construction atlhesives shall have a VOC content of 70 giL or less when calculated according to 40 CFR 59, Subpart D(EPA Method 24). Contact adhesives shall have a VOC content of 250 g/L or less when calculated according to 40 CFR 59,.Subpart D(EPA Method 24) DIVISION 7THERMAL AND MOISTURE PROTECTION 7.1 ROOF INSULATION; The roof insulation above conditioned area ceilings shall be R-19 (or as required by the energy compliance calculation), unfaced fiberglass batts; wire•tied in place as manufactured by Owens-Coming or equal. Fumish and instail a vapor barrier where requiretl by code. Where perimeter office walls do not extend to the roof deck, lay insulation on top of the ceiling tiles if code allows. Note: WSEC does not allow. 7.2 THERMAL WALL 4NSULATION: Fumish and install R-13 (or as requiretl by the energy compliance calculation) unfaced fiberglass batt insulation from floor to roof in walls between conditioned and unconditioned spaces. Furnish and install R-13 at all furred exterior concrete wall at conditioned spaces. Provide a vapor barrier where required by code. For Seattle market, install R•10 rigid insulation from floor to roof in walls between conditioned and unconditioned spaces. 7.3 ACOUSTIC INSULATION: Fumish and install 3 112" unfaced fiberglass batt acoustic insulation in all toilet and shower room walls and ceilings, and demising wall at office area. The batt insulation at office demising wall should go the full height of the wall. 7,4 INSULATION FACING: All exposed fiberglass batt insulation shall have a white PSK-25 or approved equivalent facing. 7.5 ROOFING: The contractor shall use a roofing contractor certified to install the existing roofing material for patching of all roof penetrations, Prior to the work, contractor should verify with Prologis manager for the qualified roofers. The new roof penetrations shall be made in accordance with the roofing manufacturer's recommendations, such that the existing roofing warranty is maintainad. The patch shall also meet all of the requirements stated in the building shell specifications. On built-up roofs, pipe and conduit penetraUons at the roof shall receive galvanlzed pipe flashing with screw clamp and elastomeric sealant and shall also be hot asphalt patched with 4 ply. 7.6 ARCHITECTURAL SHEETMETAL: Fumish and install sheet metal cap flashing on top of any roof mounted wood sleepers approved by owner. 7,7 FIRE SAFING: PeneVations at one hour walls shall be fire safed or caulked. . DIVISION 8 DOORS AND WINDOWS 8.1 INTERIOR DOORS AND FRAMES: Fumish and fnstall 3'-0" x 7'-0" x 1-3/4", solid core, birch, B-3 stain prefinished doors in °Timely" prefinished black steel frames (clear anodized aluminum frames by ACI, Eclipse or approved equal in the San Francisco Bay Area), with 1,112" pairs of Hager 881279 butts per door U.O.N. (All office door shall receive a 2'-0" sidelight in the San Francisco Bay and Seattie Areas). Doors receiving closers shall receive ball-bearing butts. Doors and frames shall be 20 minutes rated where required. When working in an existing tenant space, the new doors and frames shall match the existing doors and frames U.O.N. Use metal frame for door backing, wood is not allowed: . 8.2 NEW EXTERIOR DOORSIFRAMES: 20 guage, fuil flush,1-3/4" thick hollow metal with fibrous honeycomb core or steel stiffened hollow metal. Install rain drip seal on new hollow metal doors. Freme: 18 guage with 2" faces and 5/S" stops formed internal corners mitered, welded and ground smooth. 8.3 INTERIOR DOOR HARDWARE: Fumish and (nstall Schlage AL10S Satum passage hardware on all doors except single accommodation toilet rooms which shall receive Schlage AL40S privacy locks. The door hardware shall have a brushed chrome 626 finish UA,N. Fumish and install weather-stripping, closers, and drop seals at doors between conditioned and non•conditioned areas. Fumish and install closers on all toilet and shower room doors. The closer shall be fnstalled on the toilet room or warehouse sitle of the door. When working in an existing tenant space, the new door hardware shall match the existing door hardware U.O.N. 8.4 EXTERIOR DOOR HARDWARE: Match the existing building hardware. Include door closers and latch guards on all new doors. 8.5 DOOR SIGNAGE: Include all signage per code (Handicap, Exit, etc.) tio If no O.H. doors exist 8.6 OVERHEAD DOORS: Match the existing building overhead doors and door insula n, use insulated Overhead Door Company or equal with 3" track 20 gauge door vertical reinforced bottom rail, with step plate flush panel sectional. Sawcutting at exterior concrete panels must be certified by a licensed structural engineer. No overcuts will be allowed. Protect new overhead door tracks with °Zee Guards": 3/8" thick bent plate, 4 feet long, bolted to the tilt-up wall panel to protect all dock overhead door tracks 8.7 INTERIOR WINDOW FRAMESIGLASS: Interior windows shail be 1/4" clear tempered glass set in black "Timely" frames (or anodized aluminum frames in the S.F. Bay Area) to match the interior door frames. Glazing height shall match door height,. UON; width shall be as indicatad on plans. 8.8 MIRRORS: Fumish and install 4' high x 1/4" thick plate glass mirrors with two coats silve� and electroplated copper backing, and wiped edges at all lavatory vanities. The mirror shall be the length of the lavatory top set directly on top of the splash and extending to the underside of the light shelf. If wall mounted lavatories are used, the mirror shall be a Bobrick 2436. 8.9 EXTERIOR GLASS: The glass in new storefront doors and "in-filled" truck door openings shall match the existing building glass. If the building glass is a long lead item, install gray vision glass (tempered if necessary) for temporary use until building standard glass is available. 8.10 FALSE MULLIONS: Where interior drywall partitions meet the ei�erior window wall, furnish and install aluminum "false" mullions finished to match the existing exterior storefront. DIVISION 9FINISHES 9.1 FIRE RATED WALLS: Metal studs with one layer of 5/8" type "X" gypsum board on each side from the floor to the roof deck with top slip track. The stud size and spacing shall be per the stud manufacturer's tables and local cotle requirements. Install fire safing between the gypsum board and roof deck U.O.N. Penetrations at one hour walls shall be fire safed or caulked. 9.2 FULL HEIGHT DRYWALL PARTITIONS (including tenant demising walls): Metal studs with one layer of 5/8" type "X" gypsum board on each slde from the floor to the roof deck with top slip track. The stud sfze and spacing shall be per the stud manufacturer's tables antl local code requirements. Drywall installed above an acoustical ceiling shall be firetaped and screws spotted , 9.3 OFFICE DRYWALL PARTITIONS: All partitions in areas with ceilings shall be undergrid 3-518" or 3-1/2" x 25 GA. metal studs at 24" o.c. with 518" fire code type "X" gypsum board on each side. The ceiling grid shall be installed first with walls built to the grid. Tho intersection of the wall at the grid shall be snug and flush, Install "L" metal trim at the top of the wall. Toilet room perimeter walls shall be built to 6" above grid. Furr perimeter concrete walls and interior columns in office areas to 6" aboire the grid. 9.4 OFFICEITOILET RM. WALL/CEILING FINISH: All office drywall shall receive a light skip trowel textured wall finish. Denver, Salt Lake City, Portland and Sea�le area proJects shall receive a smooth finish. The skip trowel texture shall be the size of a quarter dollar coin. The finish shall be mocked-up on a 4'x4' piece of drywall on the jobsite for the owner's approval prior to final applicalion: The.toilet and shower room walls and ceilings shall have a smooth finish and drywall ceiling installed at 8'-0" A.F.F. U.O.N. 9.5 WAREHOUSE GYPSUM BOARD WALL FINISH: All drywall in the warehouse shall be fire taped oniy unless otherwise noted. Spot screws in firetaped areas 9.6 END CAPS: Where a partition meets a window mullion, fumish and install an aluminum "wall end cap" finished to match the storefront U.O.N. Install rigid 2" x 2" black foam between end cap and storefront glass if end cap does not intersect vertical mullion. 9.7 WAINSCOT: Toilet room walls shall have 4' high white FRP or plastic laminated wainscot set 6" A.F.F. U.O.N. Walis behind mop sinks, drinking fountain and laundry sinks shall receive a 4' x 4' wainscot along each side of the sink in contact with the wall. All wet walls shall receive water resistant drywall (greenboard). Walls in showers shall receive cement board backer. 9.8 ACOUSTIC CEILING TILE: Fumish and install 24" x 48" x 5/8" USG Omni non-directional fissured tile or equal, installed at 9'-0" A.F.F., U.O.N. in ail office areas except toilet and shower rooms. Use second-look ceiling tile in Seattle market 9.9 ACOUSTIC CEILING TILE SUSP[NSION SYSTEM: Furnish and install Class "A" 15/16" exposed "T" grid system, intermediate duty (heavy duty in seismic design category "D° areas) with 11/2" main tees, 11/2" cross tees, and 7/8" x 7/8" wall mold as manufactured by Donn or equal per cotle, Fire rated grid and tile shall be used where code requires. The grid color shall be white to match the tile exactly. 9.10 CARPET: Carpeting shall be Designweave, Shaw (such as Lynchburg 26 series) or approved equal, loop graphic, solution dyed 100% nylon, 26 oz. per square yard average yam weight minimum,1/10th gauge, color to be selected from manufacturer's standard colors U.O.N. Carpet shall be direct glue down U.O.N. Verify with Prolo is Mana er for final finish seleclion. 9 9 In Seattle Area: Install walkoff mat at all doors from o�ce to either exterior of the building or warehouse. The walkoff mat should be at least 4' wide or the width of the haliway by 3' deep. T h e p r o d u c t s h o u l d b e C o n n e x u s Super Nop 52 In either roll good or modular tile or equal. 9.11 VINYL COMPOSITION TILE: Fumish and install 1/8" gauge, standard grade, VCT as manufactured by Tarkett, Azrock, or Armstrong. Install VCT in server rooms and IT closets. No VCT shall be installed in toilet rooms. Verify with Prologis Manager for final flnish selection. 9.12 RUBBER BASE: All areas receiving Floor covering and new walls except the toilet rooms shall have 4" high tOpset rubber base as manufactured by Burke, Roppe, or Tarkett in a standard color. Install the ru6ber base on a continuously roll, not sectional. Verify with Prologis Manager for final finish selection. 9.13 SHEET VINYL: New toilet rooms shall receive sheet vinyl flooring with a 6" integral flashed cove base with brushed aluminum trim on the top edge. All joints shall be heat welded and receive seam sealer. The sheet vinyl shall be Corlon or Mannington Magna. If not available, need to specify later installed in all new toilet rooms. Verify with Prologis Manager for final finish selection. 9.14 TRANSITION STRIPS: Fumish and install black vinyl transition strips at all changes in flooring material U.O.N. 9.15 CERAMIC TILE: (Central Valley area only) Restrooms: Use 2x2 American 01ean ceramic tile or equal slip resistant on floors and 4x4 ceramic tile on walls as noted on plans. Grout: color to be selected from manufacturer's standard colors: The tile floor shall be cleaned after installation to remove excess mortar and grout. The grout shall be sealed per manufacturer's recommendations. Verify with Prologis Manager for final finish selection.. 9.16 CONCRETE FLOOR SEALER: All concrete floor patches shall be resealed to match the existing concrete floor sealer / hardener in warehouse areas. 9.17 PAINT: On walis rece(ving a skfp trowelled finish, apply one (1) coat of interior satin latex paint, Sherwin Williams or equal in a standard light color. Lunch / break rooms, toilet and shower rooms and the wall at the coffee bar shall receive one (1) coat of latex semi-gloss enamel over one (1) coat of PVA sealer. Smooth finished walls shall receive iwo coats of eggshell latex paint. Paint the warehouse demising wall(s) and warehouse side of the office walls one (1) coat of interior flat latex paint if required. Verify with Prologis Manager for final finish selection. All exposed warehouse coiumns 18'-0" or taller shall be painted OSHA yellow to 12'-0° from A.F.F.. The remainder of the column above 12'-0". to the roof shall be painted white. DIVISION 10 SPECIALTIES 10.1 TOILET ACCESSORIES: Napkin Disposals: Bobrick B-270 sanitary napkin disposals in each women's toilet stall U.O.N. Paper Towel Dispenser: Bobrick B-369 (for single accommodation toilet rooms) or a 8obrick B-3944 (for multiple accommodation toilet rooms) recessed paper towel dispenser with a waste receptacle U.O.N. Seat Cover Dispenser: Bobrick B-221 seat cover dispenser in each toilet stall. Toilet Paper Holder: Bobrick B-686 double toilef paper holder. Grab Bars: Bobrick No. 86806-36 and B6806-42 stainless steel per ADA. 10.2 TOILET PARTITIONS: Furnish antl install metal, floor mounted, overhead braced toilet partitions with a backed : enamel finish by Global Partitions, Knickerbocker or equal in manufactures standard "quick ship" color. 10.3 SIGNAGE: Furnish and install all handicap and exit signage as required by code. DIVISION 11 DOCK EQUIPMENT 11.1 MANUFACTURER: All dock equipment when required by the customer as an upgrade shall be Arbon, Kelly I Serco, Nordock or Powerramp. 11.2 LEVELER PIT: All exposed edges of the dock leveler pit shall be protected with steel comer angles. The existing steel angle or channel at the face of the existing dock shall be replaced with new steel integrally tied to the new pit. Do not overcut the comers when sawcutting the concrete slab for the new pik On the exterior wall, all edges must have a clean'/." chamfer, accomplished by grinding or sawcutting the existing concrete with a'/+" chamfer and pouring the new concrete with a%." chamfer. 11.3 DOCK LEVELERS: Mechanical 6' x 8' 35,000 Ib. capacity Arbon, Kelly / Serco, Nordock or Powerramp with recessed pit per manufacturer's detaiL 11.4 EDGE OF DOCK LEVELERS: 72" wide x 3,000 Ib. capacity Arbon, Kelly / Serco, Nordock or Powerramp. The EOD must be mounted per manufacturer's instr�ctions and must be installed with a transition plate extending 12"minimum into the building if there is no existing steel channel in the dock. Sawcut transition plate into the concrete floor at the leadfng edge . • 11.5 DOCK SEALS: 16 oz. black vinyl and 40 oz. vinyl wear pleats with an 8" exposure. The projection shall be 10" standard or 21" at E.O.D: s including wood biockouts. 11.6 DOCK SHELTERS: The fabric shall be 40 oz black hyplon. The projection shall be 24" standard and 36" at E.O.D.'s. 11.7 DOCK LIGHTS: Adjustable dock loading light with 40" extension. DIVISION 12 FURNISHINGS 12.1 BLINDS: All exterior windows, including exterior warehouse windows and windows above any acoustic ceilings, shall receive mini-blinds by Bali "Classic" or approved equal, with a valance, in a color to match the storefront aluminum color U.O.N. The blinds shall be "inside mounted" (between the vertical window mullions) flush with the inside face of the mullion. Storefront doors and any interior windows shall not receive blinds. Install blinds at all door sidelights. ' DIVISION 15 PLUMBING 15.1.1 DESIGN BUILD: Unless engineered plumbing system drawings are included in the bid documents, the plumbing work shall be performed on a design-build basis. The design-build plumbing contractor shall furnish and install a complete and operative plumbing system to meet all local and state codes. 15.1.2 PLANS: Provide plumbing plans for architect's and owner's review and approvaL 15.1.3 SEWER LINES: Sewer, soil and waste lines within the building below the finished floor elevation shall be schedule 40 ABS plasUc or schedule 40 PVC plastic pipe. Sewer, soil and waste lines within the building above the finished floor elevetion shall be standard weight cast iron. ABS piping may be used above the finished floor if nd a roved b the owner. permitted by code a pp y 15.1.4 GAS LINES: All gas lines shall be run under the roof above the bottom cord of the trusses perpendicular or parallel to the existing roof structure. All new and existing gas lines within a single tenant space shall be connected to a separate gas meter. 15.1.5 PIPE MATERIAL; All pipe materials shall be subJect to the requirements of the City and/or goveming body. All domestic water, condensate and smitty pan drain lines must be copper. 15.1.6 PLUMBIN� FIXTURES AND TRIM; Lavatory for vanity: American Standard, " Cadet Everclean- Oval Countertop sink", model 0419.444EC, white, self-rimming or equal with a Delta Model 523LF HDF or Moen L4601 single lever type faucet assembly with a grid strainer and bright chrome finish. Furnish and install a Handy-Shield Drain Cover #3011 White by Plumberex Specialry Products under each lavatory. Wall-hung lavatory: American Standard, "Lucerne", model 0355.012, white, wall mounted lavatory or equal with a Delta Model 523 LF HDF single lever type faucet assembly with a grid strainer and bright chrome finish. Fumish and install a Handy-Shield Drain Cover #3011 White by Plumberex Specialty Products under each lavatory. Water closet: American Standard, " Madera FloWise- Right Height" elongated, flush valve toilet,17" height, model 3043.001 or approved equal in white, with an Olsonite #95 seat and a Sloan #111 flush valve Urinal: American Standard, "Washbrook FloWise", model 6590.125, or approved equal, white, with a 3/4" top spud. For Portland Area: American Standard, "Washbrook FloWise", model 6590.125, or approved equal, white. Coffee bar / Lunch Room sink: Elkay, model LRAD 1918, stainless steel, with a Delta #100 faucet If the Lunch Room base cabinet is 8'-0" or longer, use an Elkay model GECR 2521. Fumish and install a Handy-Shield Drain Cover #3011 White by Plumberex Specialry Products under each sink. ' Laundry tray: When specified as a customer upgrade use Fiat Products, Molded-Stone, model FL-1, with 20 gallon capacity, or Florestone Model FM Utility Sink with a Delta model 2123 laundry tub faucet. Shower enclosure: When specified as a customer upgrade use Flo�estone, wheelchair accessible fiberglass shower stall, 44-52H white with grab bars, seat, mi�ting valve and shower curtain rod. Water heater: The water heater shall be A.O. Smith, State or approved equal sized to meet the demand. It shaU be located on the warehouse floor in a smitty pan draining into a hub drain with a frap primer. The locetion shall be as located by the architect or approved by the owner. All plumbing connections shall be matle with dielectric unions. Install the water heater above the ceiling is not allowed. Drinking fountain: If drinking fountafn is specified on the plan, Elkay model EZSTLSLC, for the high-low drink fountain. If the local jurisdiction requires the protection for blind person, use Bobrick model "819298" grab bar;1 '/:" stainless steel. Install two grab bar, one at each end of the fountain. 15.1.7 CONDENSATE DRAINS: Fumish and install copper condensate drainage lines with proper venting for all HVAC equipment. The lines shall be no smaller than 314" diameter and shall be located under the roof unless prchibited ' by code. PVC condensate line may not be used. In Reno, provide evaporator pans set in roof mastic. 15,1.8 SHUT-OFF VALVE: Fumish and install a main water line shut-off valve for the Resirooms in the handicapped stall in the men's restroom, not above the ceiling, with an 8" x 8" painted steel access panel. Provide a typed label "Main Water Valve" on the access panel. 15.1.9 MAIN WATER LINE: If a main domestic water line is not existing above the tenant space, fumish and insbll a 2" diameter copper water line at the roof installed above the bottom cord of the Uusses, properly braced ta avoid movement. At each future tenant space that the line crosses, install a 2" "T" with 2" gate valve (one vaVe per storefront door). Extend the water line through the tenant demising wall into the "down stream" adjacenttenant space with a 2" diameter gate valve. Furnish and install a 2" pressure reducing valve with an access pand at the water service enUance when required. 15.1.10 HOSE BIB: Provide one rooftop hose bib if not existing (Freeze proof where required). 15.1.11 CLEAN-OUTS: Fumish and install a brass floor clean-out cove� at the proper finished elevation as requ�ed. if lhe clean-out is in the warehouse area, furnish and install a cast iron heavy duty traffic rated cover. DIVISION 15 FIRE PROTECTION 15.2.1 DESIGN BUILD: The fire protection work shall be performed on a design-build basis. The design-build fire protection contractor shall furnish and install all modifications to the existing fire sprinkler system to neet all applicable local and state fire code requirements. Sprinkler heads shall be dropped into all suspendedceiling areas. Upgrade of existing system shall conform with a class IV occupancy. In buildings with ESFR srstems, maintain the necessary clearances from all obstructions. 15.2.2 PIPE MATERIAL: All fire sprinkler piping shall be standard schedule 10 for 6" piping, and schedule 7 for 4' and 2 Y�" piping U.O.N. Schedule 5 pipe may not be used. ' 15.2.3 SPRINKLER HEADS: The fire sprinkler heads in areas with ceilings shall be chrome, semi-recessed, wih white escutcheons. When "second look" acoustical ceiling tiles are used, sprinkler heads shall be centered on he half tile. 15.2.4 HYDRAULIC TESTING: The contractor shall include the cost of any required hydraulic testing of he fire sprinkler system. 1 5. 2. 5 F I R E E X T I N G U I S H E R S: F i r e e x t i ng u i s h e r s s h a l l b e f u r n i s h e d a n d i n s t a l l e d p e r ci ty f ir e c o d e. E x tinguishas may be wall hung. 15.2.6 SYSTEM SHUT DOWN: The building may be equipped with an ESFR fire protection system and boostei pump. The pump must be turned off prior to causing any flow in the system. The pump must bo turned t�ck on immediately after flow is complete each day. Hoses must be used to drain down the system to avoid stahing of concrete and asphalt surfaces and damage to landscape areas. Contact the Owner's property managerprior to performing any work on the fire system, or deactivaGng the pump. DIVISION 15 HVAC 15.3.1 DESIGN BUILD: Unless engineered HVAC system drawings, are included in the bid documents, the HVA:, work shall be performed on a design-build basis. The design shall be based upon ASHRAE standards, local coie, and weather data. Caiculations shall be provided upon owner request. The design-build HVAC contractur shall fumish and install a complete and operative HVAC system to meet all local and state codes. 15.3.2 PLANS; Provide HVAC plans forarchitect's and owner's review and approvaL 15.3.3 WARRANTY AND SERVICE: All work shall include a one year parts and labor warranty, a five year com�ressor parts warranty and a 90 day service contract from the date of project compleiion. 15.3.4 UNITS: The HVAC units shall be gas/electric, bottom discharge, as manufactured by Carrier, Trane, Lemox, or York. Units shall be installed on a leveled, manufactured curb. All rooftop equipment shall be seisnically fastened to the structure. Side discharge units may not be used. Commercial grade heat pumps by Carrier (model 50TCQ), or Trane (model WCD) only may only be used in the Las Vegas or Phoenix markets. Wh.n heat pumps are used, they must be installed with auxiliary strip heaters and single point wiring kits. Furnish and install economizers on all units larger than five tons and whenever required by the energy wde. For Denver a�d Salt Lake City areas, provide hail guards on rooftop units 15.3.5 UNIT LOCATIONS: HVAC and evaporative coo�er units (when used) shall be located on roof, adjacent to a glulam beam or girder, at or near a sUuctural column, set back from bu'ilding edge to hide �hem fron sight. Framing for roof penetrations and supports for all roof-top equipment must be reviewed, approved and �amped by a structural engineec 15.3.6 EVAPORATIVE COOLER: Evaporative coolers when specified as a customer upgrade shall provide a rrinimum of four air changes per hour U.O.N. The coolers shall be United Metal Products "Slimline" units or approved equals. Provide adequate relief venting to allow all doors within the tenant space to close properly. The cooler plenums shall be located midway between fire sprinkler lines and fire sprinkler heads in buildings with ESFR buildings. The plenums, water supply lines and drain lines shall not encroach into the building's cleai space U.O.N. 15.3.7 CURBSISLEEPERS: All mechanical units (HVAC units, evaporative coolers, and relief vents) shall be loated on roof and shall be installed with a self flashing, leveled, factory curb. Furnish and install 4 inch leg cart strips around all curbs. Absolutely no wood or metal sleepers may be used without owner's written permission. 15.3.8 CONTROLS: The HVAC system shall be connected to a 7-day digital programmable thermostak All thermostats shall be mounted at 48" A.F.F. and shall have an automatic change-over feature. If freeze protection only is installed in the warehouse, the thermostat control should be mounted on the nearest building cniumn at 10' AFF and aligned away from racking. 15.3.9 EXHAUST FANS: Fumish and install an exhaust fan in each toilet room and shower room (if applicable). Instail a supply air grille in the toilet rooms or a transfer grille from the toilet ! shower room ceilirg to the adjacent conditioned space. In multi-fixture restrooms, fans shall be rated at 150 CFM minimum. 15.3.10 DUCTING: All ductirig shall be galvanized spiral, or rectangular insulated with 1-1/2" wrap and vapor barrier or duct board. Any exposed duct in a conditioned warehouse area must be galvanized spiral sheet metal Final connections to the registers shall be made with a minimum 5' soft flex duct for sound attenuation, All plenums shall be fabricated from insulated galvanized sheet metal of appropriate gauge for low pressure use. Fienums shall extend from the unit to the level of the horizontal branches. No ducting or plenum drops may be iistalled over warehouse space. Spray paint flat black any ducting visible through the grille. If the project is a rerr.odel of an existing system, all abandoned ducting shall be removed. 15.3.11 FITTINGS: All wye branch fittings shall have volume dampers with locking quadrant in main and branch ducts. The dampers shall be tagged for easy recognition. 15.3.12 GRILLES: All conditioned areas shall have a supply register and a ducted retum register. Transfer grillsare not permitted in the office area. Supply and retum air registers shall be white baked enamel 2'x2' with a peforated face, flush mounted. Supply air registers shall have a 4-way directional blow. Restroom registers mey be 1'x2' if necessary. 15.3.13 FILTERS: Filters shall be located at the unit not at the return register. Replace all existing filters a`ter ihe completion of the construction. DIVISION 16 ELECTRICAL 16.1 DESIGN BUILD; Unless engineered electrical system drawings are included in the bid documents, the eectrical work shall be performed on a design-build basis. The design-build electrical conUactor shall fumish and 'nstall a complete and operative electrical system to meet all local and state codes. 16.2 PLANS: Provide electrfcal plans for architecYs and owner's review and approvai. 16.3 ENERGY CALCS: Provide energy compliance code lighting calculations if required. 16.4 METER SECTION: Fumish and install an electrical meter secGon "bussed for future" sections if not existirg. 16.5 PANELS AND TRANSFORMERS: The locations of the 277/480 volt electrical panel, the transformer, and the 120/208 volt electrical panel shall be approved by the owner. Typically these should be located on ihe office/warehouse wall adjacent to the tollet rooms. The electrical panels and transformer shall be sized ;o allow for a 25% increase in the number of circuits in the future. 16.6 OFFICE LIGHTING: See updated LED IighUng spec, per Prologis this sheet. 16.7 TOILET ROOM LIGHTING: See updated LED IighUng spec, per Prologis this sheet. 16.9 OUTLET BOXES: All outlet boxes for wall switches, wall receptacles, telephone, etc. shall be galvanized steel or cast e boxes. �Yp 16.10 RECEPTACLES: Furnish and install two (2)110V dupiex receptacles and one (1) telephone "ring and sring" in each office. 16.11 DEDICATED RECEPTACLES: Fumish and install a dedicated 110 volt fourplex outlet at the telephon: board and two dedicated 110V outlets at the coffee bar. Provide a dedicated 20 AMP GFI receptacle if within 6 of any sink; 16.12 GFI RECEPTACLES: Provide one GFI electrical outlet in each toilet room. Install GFI receptacles Hnerever requfred by cade. 16.13 WAREHOUSE SWITCHING: The warehouse lighting must be controlled from light switches at the officelwarehouse door or other owner approved location, not at the electrical paneL 16.14 ELECTRICAL CONDUIT / CONDUCTOR MATERIAL: All conduit shall be EMT. MC cable may be used in lieu of EMT where permitted by code. Romex may not be used: All conductors must be copper. 16.15 CONDUIT INSTALLATION: All conduits in areas withoufceilings shall be installed at or above the bottoms of the trusses or beams: All conduits shall be run at 90 degrees or parallel to structural members, walls flo�rs and ceilings. No conduit may be installed below the slab or on top of the roof without tha owner's written permssion. 16.16 TELEPHONE BOARD: Fumish and install one, 4'x8'x314", APA C-D piugged (paint grade), fire retardant plywood telephone backboard for mounting customer's electrical or telephone equipment. Provide No. 6 copperground wire unless otherwise required. 16.17 TRIM COLOR: All light switches, outlets and electrical trim shall be white. 16.18 LABELING: Label all panels, control points, switches, and motors as directed. Panels shall be identified ty panel number. Switches shall be labeled indicaGng the equipment which they control. Typed (circuit) panel dir.ctories are to be supplied and installed 5 „ .■ , � • • / '.B. BOTH SIDES OVER MTL (SIZE PER PLAN) @ 2'-0" O.C, �OUND BATTS AS REQ. Y" FRAME PER STANDARDS SILENCERS. PER FINISH �ARDS, # DOOR JAMB SIMILAR R H EA D D ETA I L 3�,_�,_�,� : PLASTIC LAMINATE PER FINISH STANDARDS ALL SURFACES PROVIDE FILLER OR FINISHED SIDE AS 6'-0" REQ. � CV ' _ q °° � � 0 CV i � �� �� � I I � I I � � _ � SINK i l l� i l l� � � � / 3'-0" 3'-0" 518" TYPE "X" GWB OVER MTL STUDS (SIZE PER PLAN) PAINT TO MATCH EXISTIN�. SOUND BATT AS REQ. XDNI POWER DRIVEN HILTI FASTENER 24" OC EMBED 1-1/2" RUBBER BASE TO MATCH BLDG, STANDARD PATCH & REPAIR AS REQ'D. TO RECEIVE FINISH PER SCHEDULE ADJUSTABLE SHELVES, TYP. 24" DEEP COUNTER � ! NO BASE UNDER SINK TO PROVIDE 4" INTEGRAL P. LAM. WHEELCHAIR ACCESS. SPLASH NOTE; FIELD VERIFY SIZE OF BREAKROOM PRIOR TO CASEWORK FABRICATION, A EW RK ELEV. � � O � ��4„_�,_�„ ���� ��s 2s5'd �; �:y a Y t � ". u s'������,A;fiian���. ��.� ��d �' '�§tis,sz u 2§s, fs � s � fi. � • � � � � � � � 5719 . REGISTERED CHIT CT � r ROBERT A. KROESE I STATE OF WASHINGTON Jackson � Main Architecture 311 First Avenue S. Seattle, Washington 98104 t 206.324.4800 e-mail: gregg.percich@jacksonmain.com These plans and specifications are the property of Jackson � Main Architeture, P.S. These documents may not be copied, reproduced, used or implemented in any way, in part or in whole, without the written consent of Jackson � Main Architecture, P.S, All common law rights of copyright are hereby speciflcally reserved. Print Record 06/17/2016 FOR OWNER REVIEW 06/20/2016 FOR PERMIT Revision Record KEN O�D ANUFACTURING UPLAND DISTRIBUTION CENTER 1131 ANDOVER PARK WEST TUKWILA , WASHINGTON 98188 �ECE{VED �;i-rv oF -ruKwi�a � ,➢U� 2 � � �Q�6 � � � €�� ' �RMIT CENTER �s � ` � f � � � ,���" � »,����n� � �� � �`" w,,� � ��.. � �� � � '� � � � ��� „��.�� �r �, d �'� � � .: s�"� , . , t �„ �. �� �k.� � � �� ;��� °� , � � � � � 12720 Gateway DR Suite 110 Tukwila, WA 98168 . Telephone: 206.414.7600 Facsimile: 206.414.7601 Date Project No. 06120116 16008.46 Sheet Title DETAILS & GUSTOMER FINISH STANDARDS Sheet Na m ❑ Released for Construction Not Released for Construction