HomeMy WebLinkAboutPermit D16-0196 - CHURCH OF THE VIETNAMESE MARTYRS - TEMPORARY ACCESS RAMPCHURCH OF THE
VIETNAMESE MAR S
6841 S 180TH ST
D16-0196
� City of Tukwila
• Department of Community Development
• 6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
'' ` Phone: 206-431-3670
Inspection Request Line: 206-438-9350
Web site: http://www.TukwilaWA.sov
Parcel No: 3623049087
Address: 6841 S 180TH ST
DEVELOPMENT PERMIT
Permit Number: D16-0196
Issue Date: 8/10/2016
Permit Expires On: 2/6/2017
Project Name: CHURCH OF THE VIETNAMESE MARTYRS
Owner:
Name: ARCHDIOCESE OF SEATTLE
Address: 710 9TH AVE C/0 ROY ANNIE,
SEAITLE, WA, 98104
Contact Person:
Name: KIEN NGUYEN
Address:
Contractor:
Name:
Address:
License No:
Lender:
Name:
6841 S 180 ST, TUKWILA, WA, 98188
OWNER AFFIDAVIT
a
Phone: (253) 951-6449
Phone:
Expiration Date:
Address: , , ,
DESCRIPTION OF WORK:
TEMPORARY ACCESS RAMP FOR RELIGIOUS PROCESSION. RAMP TO BE REMOVED BY AUGUST 24, 2016.
Project Valuation: $2,000.00 Fees Collected: $224.66
Type of Fire Protection: Sprinklers:
Fire Alarm:
Type of Construction: Occupancy per IBC:
Electrical Service Provided by: TUKWILA Water District: TUKWILA
Sewer District: TUKWILA
Current Codes adopted by the City of Tukwila:
International Building Code Edition:
International Residential Code Edition:
International Mechanical Code Edition
Uniform Plumbing Code Edition:
International Fuel Gas Code:
Public Works Activities:
Channelization/Striping:
Curb Cut/Access/Sidewalk:
2015 National Electrical Code:
2015 WA Cities Electrical Code:
2015 WAC 296-46B:
2015 WA State Energy Code:
2015
2014
2014
2014
2015
Fire Loop Hydrant:
Flood Control Zone:
Hauling/Oversize Load:
Land Altering: Volumes: Cut: 0 Fill: 0
Landscape Irrigation:
Sanitary Side Sewer: Number: 0
Sewer Main Extension:
Storm Drainage:
Street Use:
Water Main Extension:
Water Meter: No
Permit Center Authorized Signature:,��W Date: D
I hearby certify that I have read and examined this permit and know the same to be true and correct. All
provisions of law and ordinances governing this work will be compiied with, whether specified herein or not.
The granting of this permit does not presume to give authority to violate or cancel the provisions of any other
state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this
development permit agree to the conditions attached to this permit.
Signature: Date: (� t ��'
Print Name: ����'j � �l� �
This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if
the work is suspended or abandoned for a period of 180 days from the last inspection.
PERMIT CONDITIONS:
1: Ramp must be removed by 9/1/2016.
2: ***BUILDING PERMIT CONDITIONS***
3: Work shall be installed in accordance with the approved construction documents, and any changes made
during construction that are not in accordance with the approved construction documents shall be
resubmitted for approval.
4: All permits, inspection record card and approved construction documents shall be kept at the site of work
and shall be open to inspection by the Building Inspector until final inspection approval is granted.
5: All construction shall be done in conformance with the Washington State Building Code and the
Washington State Energy Code.
6: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap
the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks,
wells, and other excavations. Final inspection approval will be determined by the building inspector based
on satisfactory completion of this requirement.
7: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila
Permit Center.
8: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an
approval of, any violation of any of the provisions of the building code or of any other ordinances of the City
of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other
ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction
documents and other data shall not prevent the Building Official from requiring the correction of errors in
the construction documents and other data.
PERMIT INSPECTIONS REQUIRED
Permit Inspection Line: (206) 438-9350
1700 BUILDING FINAL**
0409 FRAMING
CITY OF TUKy► �LA
Community Development Department
Public Works Department
Permit Center
6300 Southcenter Blvd., Suite 100
Tukwila, WA 98188
http://www. TukwilaWA. gov
SITE LOCATION
Site Address: �7 c
Tenant Name:
Building Permit No. �' � �D �q �
Project No.
Date Application Accepted: � l ��
Date Application Expires:
(For office use only)
CONSTRUCTION PERMIT APPLICATION
Applications and plans must be complete in order to be accepted for plan review.
Applications will not be accepted through the mai] or by fax.
**Please Print**
S
Co Assessor's Tax No.:
� Suite Number: Floor:
`'�' ew Tenant: ❑ ..... Yes .. No
H:�Applications�Forms-Applications On Line�20] 2 Applications�Permit Application Revised - 2-7-12.docx
Revised: February 2012
bh
Page 1 of 4
r
BUILDING PERMIT INFORMATIC 206-431-3670
� -_ -P,� --
Valuation of Project (contractor's bid price): $ �(�
Describe the scope of work (please provide detaile information):
.� s L �5' _��1 , ' ��'�
��S ���� �
Will there be new rack storage? ❑.... Yes
Existing Building Valuation:
�
��-�,� � � �-p��
[�No If yes, a separate permit and plan submittal will be reyuired.
Provide All Building Areas in Square Footage Below
Addition to Type of Type of
Existing Construction per Occupancy per
Existin Interior Remodel Structure New IBC IBC
IS` Floor
2" Floor
3` Floor
Floors thru
Basement
Accessory Structure*
Attached Garage
Detached Garage
Attached Carport
Detached Carport
Covered Deck
Uncovered Deck
PLANNING DIVISION:
Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches)
*For an Accessory dwelling, provide the following:
Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling:
*Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence.
Number of Parking Stalls Provided: Standard: Compact: Handicap:
Will there be a change in use? ❑....... Yes ❑....... No If "yes", explain:
FIRE PROTECTION/HAZARDOUS MATERIALS:
❑ ....... Sprinklers ❑ .......Automatic Fire Alarm ][�....... None ❑....... Other (specify)
Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑.......Yes ❑...... No
If "yes', attach list of materials and storage locations on a separate 8-1/2" x II " paper including quantities and Material Safety Data Sheets.
SEPTIC SYSTEM
❑.......On-site Septic System — For on-site septic system, provide 2 copies of a current septic design approved by King County Health
Department.
H:Vipplications�F'orms-Applications On Line�2012 Applications�Permit Application Revised - 2-7-12.docx
Revised: February 2012 Page 2 of 4
bh
O
I YUBLIC WORKS PERMIT INF(.y QATION - 206-433-0179
Scope of Work (please provide detailed information):
Call before you Dig: 811
Please refer to Public Works Bulletin #1 for fees and estimate sh�et.
Water District
❑.. Tukwila ❑... Water District # 125 ❑... Highline
❑ .. Water Availability Provided
Sewer District
❑ .. Tukwila ❑...Valley View ❑...Renton
❑.. Sewer Use Certificate ❑...Sewer Availability Provided
❑... Renton
❑... Seattie
Septic Svstem:
❑ On-site Septic System — For on-site septic system, provide 2 copies of a current septic design approved by King County Health Department.
Submitted with Aoplication (mark boxes which aaplvl:
❑.. Civil Plans (Maximum Paper Size — 22" x 34")
❑.. Technical Information Report (Storm Drainage) ❑... Geotechnical Report ❑.. Traffic Impact Analysis
❑ .. Bond ❑... Insurance ❑... Easement(s) ❑... Maintenance Agreement(s) ❑ .. Hold Harmless — (SAO)
❑ .. Hold Harmless — (ROW)
Proposed Activities (mark boxes that ap�lv):
❑.. Right-of-way Use - Nonprofit for less than 72 hours ❑... Right-of-way Use - Profit for less than 72 hours
❑.. Right-of-way Use - No Disturbance ❑... Right-of-way Use — Potential Disturliance
❑ .. Construction/Excavation/Fill - Right-of-way ❑
Non Right-of-way ❑
❑ .. Total Cut cubic yards
❑ .. Total Fill cubic yards
❑ .. Sanitary Side Sewer
❑ .. Cap or Remove Utilities
❑ .. Frontage Improvements
❑ .. Traffic Control
❑ .. Backflow Prevention - Fire Protection
Irrigation
Domestic Water
❑... Work in Flood Zone
❑... Storm Drainage
❑... Abandon Septic Tank
❑... Curb Cut
❑... Pavement Cut
❑... Looped Fire Line
❑.. Permanent Water Meter Size (1) " WO #_
❑.. Temporary Water Meter Size (1) " WO #
❑.. Water Only Meter Size ........... " WO #
❑.. Sewer Main Extension............ Public ❑ Private ❑
❑.. Water Main Extension ............ Public ❑ Private ❑
FINANCE INFORMATION
Fire Line Size at Property Line _
❑ .. Water ❑ .. Sewer
Monthlv Service Billing to:
Mailing
Water Meter RefundBilline:
Name:
Mailing Address:
❑... Grease Interceptor
❑... Channelization
❑ ... Trench Excavation
❑... Utility Undergrounding
(2) " WO # (3) " WO #
(2) " WO # (3) " WO #
_ ❑ .. Deduct Water Meter Size "
Number of Public Fire Hydrant(s)
❑ .. Sewage Treatment
H:Wpplications�Forms-Applications On Line�2012 Applica[ionsV'ermi[ Application Revised - 2-7-12.docx
Revised: February 2012
bh
Day Telephone:
City
Day Telephone:
City
State Zip
State Z�p
Page 3 of 4
PERMIT APPLICATION NOTES —
Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject
to possible revision by the Permit Center to comply with current fee schedules.
Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation.
The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be
requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition).
I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER
PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT.
BUILDING OWNER OR AUTHORIZED AGENT:
Print Name: � I� l��t V 1 V-�
Mailing Address:
Date:
Day Telephone: L��' ��� ' i�''� ► �/
c�cy
State Zip
H:Wpplications�Forms-Applications On Line�2012 Applications�Pertnit Application Revised - 2-7-]2.docx
Revised: February 2012 PflgC 4 of 4
bh
Date Paid: Tuesday, July 19, 2016
Paid By: KIEN NGUYEN
Pay Method: CREDIT CARD 90924P
Printed: Tuesday,luly 19, 2016 2:45 PM 1 of 1 ('--�;r �f 'T �;�� YSTEMS
' INSPECTION RECORD
Retain a copy with permit ��� s�f��
IN TIOPI N0. PERMIT N0.
CITY OF TUKWtLA BUILDING DIVISION .
6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670
Permit Inspection Request Line (206) 438-9350
�Appr�oved per apptitable codes. � Correuions required prior to approval.
nspector:
�� /
� REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be
paid at 6300 Southcenter Blvd.. Suite 100. Call to schedute reinspection.
�
IN5PECTION RECORD /
1 Retain a copy with permit �� b���
SPECTION N0. PERMIT N0.
CITY OF TUKWILA BUILDING DIVISION .
6300 Southcenter Blvd., #100, Tukwila: WA 98188 (206) 431-3670
Permit Inspection Request Line (206) 438-9350
� REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be
paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection.
. �ER�IIT COORD CaPY
PLAN REVIEW/ROUTING SLIP
PERMIT NUMBER: D16-0196
DATE: 07/22/16
PROJECT NAME: CHURCH OF THE VIETNAMESE MARTYRS
SITE ADDRESS: 6841 S 180TH ST
X Original Plan Submittal
Response to Correction Letter #
Revision # before Permit Issued
Revision # after Permit Issued
DEPARTMENTS:
�S �'t�t1 �; �J�-���' �O �--fi'� ��iA- �'�-��( � I� ,�G i �-!�
Building Division � Fire Prevention � Planning Division �
�� �/� �J��-J� I
Public Works � Structural � Permit Coordinator �
PRELIMINARY REVIEW: DaTE: 07/21/16
Not Applicable �
(no approval/review required)
REVIEWER'S INITIALS:
Structural Review Required �
i.�:v�
APPROVALS OR CORRECTIONS: DUE DATE: Og�iH�16
Approved
❑ Approved with Conditions �
Corrections Required ❑
(corrections entered in Reviews)
Notation:
I�����li.�l� �.`)1►7�/:�I1C`�
Denied �
(ie: Zoning Issues)
DATE:
Permit Center Ilse Ondy
CORRECTION LETTER MAILED:
Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials:
12/IR/2013
�J,�Wi�n yyqsy Permit Center/Building Division
C��� �� T����� 206 43i-36�o
�` �� Department of Community Deuelopment Public Works Department
� % ':2
��� ;�0 6,30o Southcenter Boulevard, Tukwila, WA 98i88 206 433-0179
�''•• '= Telephone: (206) 431-36�o FAX (206) 43i-,366,5 Planning Division
�' `"r90S"��� E-mail: tukplannaci.tukwila.wa.us 2o643i-367o
AF�IDE3VIT' IlOT I.IEIJ OF COIVT�CTOIZ 1�GIS7['I��'IOlV
����� ����� ��
PERMIT NO: � � � i �- i �.� �
r, ' ,, e,,�,-�---
STATE OF WASHINGTON)
) ss.
COUNTY OF KING )
F
� �� ��./ �� �`--�� , states as follows:
[please print name]
i. I have made application for a permit from the City of Tukwila, Washington.
2. I understand that state law requires that all building construction contractors be registered with the
State of Washington. The exceptions to this requirement are stated under Section i8.2�.090 of the
Revised Code of Washington, a copy of which is printed on the reverse side of this Affidavit. I have
read or am familiar with RCW i8.2�.090.
3. I understand that prior to issuance of a permit for work which is to be done by any contractor, the
Ciry of Tukwila must verify either that the contractor is registered by the State of Washington, or that
one of the exemptions stated under RCW i8.2�.090 applies.
4. In order to provide verification to the City of Tukwila of my compliance with this requirement, I
hereby attest that after reading the exemptions from the registration requirem nt of RCW i8.2�.090,
I consider the work authorized under this permit to be exempt under number �, and will therefore
not be performed by a registered contractor.
5. I understand that the licensing provision of RCW i9.28.i6i through i9.28.2�i shall not apply to
persons making electrical installations on their own property or to regularly employed employees
working on the premises of their employer. The proposed electrical work is not for the construction
of a new building for rent, sale or lease.
I understand that I may be waiving certain rights that I might otherwise have under state law in any decision
to engage an unregistered contractor to perform construction work.
� �°.
,-- � �'� �A� ✓ '�
� ner70wner's g�nt* '
( �� G�
�
IAURlE A. WER�.E
NOTARY PUBLIC
STATE OF WASHINGTON
COMMISSIQN EXPIRES
MAY 29, 201$
Signed and sworn to before me this
��' :�.--
da�,of , . � G� ' _ , 20.�
, �
�� � C�� -�` -C
�'i'� �f �.� �
I��OTARY PUBLIC in and for the State of Washington
.
Residing at /��� , County
/�
Name as commissioned: //2(�z���L��l� ���'����
Mycommissionexpires: / (,�S('��(f�
18.27.ogo Exemptions. The stration provisions of this chapter do not app
i. An authorized representative of the United States
government, the state of Washington, or any incorporated
city, town, county, township, irrigation district, reclamation
district, or other municipal or political corporation or
subdivision of this state;
2. O�cers of a court when they are acting within the scope
of their ofFice;
3. Public utilities operating under the regulations of the
utilities and transportation commission in construction,
maintenance, or development work incidental to their own
business;
4. Any construction, repair, or operation incidental to the
discovering or producing of petroleum or gas, or the
drilling, testing, abandoning, or other operation of any
petroleum or gas wel] or any surface or underground mine
or mineral deposit when performed by an owner or lessee;
5. The sale of any finished products, materials, or articles of
merchandise that are not fabricated into and do not become
a part of a structure under the common law of fi}ctures;
6. Any construction, alteration, improvement, or repair of
personal property performed by the registered or ]egal
owner, or by a mobile/manufactured home retail dealer or
manufacturer licensed under chapter 46.�o RCW who shall
warranty service and repairs under chapter 46.�o RCW;
�. Any construction, alteration, improvement, or repair
carried on within the limits and boundaries of any site or
reservation under the legal jurisdiction of the federal
government;
8. Any person who only furnished materials, supplies, or
equipment without fabricating them into, or consuming
them in the performance of, the work of the contractor;
9. Any work or operation on one undertaking or project by
one or more contracts, the aggregate contract price of
which for labor and materials and all other items is less
than five hundred dollars, such work or operations being
considered as of a casual, minor, or inconsequential nature.
The exemption prescribed in this subsection does not apply
in any instance wherein the work or construction is only a
part of a]arger or major operation, whether undertaken by
the same or a different contractor, or in which a division of
the operation is made into contracts of amounts �ess than �
five hundred dollars for the purpose of evasion of this
chapter or otherwise. The exemption prescribed in tl4is
subsection does not apply to a person who advertises or
puts out any sign or card or other device which might
indicate to the public that he or she is a contractor, or that
he or she is qualified to engage in the business of
contractor;
io. Any construction or operation incidental to the
construction and repair of irrigation and drainage ditches
of regularly consti±uted irrigation districts or reclama±ion
districts; or to farming, dairying, agriculture, viticulture,
horticulture, or stock or poultry raising; or to clearing or
other work upon land in rural districts for fire prevention
purposes; except when any of the above work is performed
by a registered contractor;
ii. An owner* who contracts for a project with a registered
contractor, except that this exemption shall not deprive the
owner of the protections of this chapter against registered
and unregistered contractors. The exemption prescribed in
this subsection does not apply to a person who performs
the activities of a contractor for the purpose of leasing or
selling improved property he or she has owned for less than
twelve months;
i2.* Any person working on his or her own property,
whether occupied by him or her or not, and any person
working on his or her personal residence, whether owned
by tiim or her or not but this exemption shall not apply to
any person who performs the activities of a contractor on
his or her own property for the purpose of selling,
demolishing, or leasing the property;
i3. An owner* who performs maintenance, repair, and
alteration work in or upon his or her own properties, or
who uses his or her own employees to do such work;
i4. A licensed architect or civi] or professional engineer
acting solely in his or her professional capacity, an
electrician certified under the laws of the state of
Washington, or a plumber certified under the laws of the
state of Washington or ]icensed by a political subdivision of
the state of Washington while operating within the
boundaries of such political subdivision. The exemption
provided in this subsection is applicable only when the
person certified is operating within the scope of his or her
certification;
i5. Any person who engages in the activities herein
regulated as an employee of a registered contractor with
wages as his or her sole compensation or as an employee
with wages as his or her sole compensation;
i6. Contractors on highway projects who have been
prequalified as required by RCW 47.28.0�0, with the
department of transportation to perform highway
construction, reconstruction, or maintenance work;
i�. A mobile/manufactured home dealer or manufacturer
who subcontracts the installation, set-up, or repair work to
actively registered contractors. This exemption only applies
. to the installation, set-up, or repair of the
R mobile/manufactured homes that were manufactured or
sold by the mobile/manufactured home dealer or
manufacturer;
i8. An entity who holds a valid electrical contractor's
license under chapter i9.28 RCW that employs a certified
journeyman electrician, a certified residential specialty
electrician, or an electrical trainee meeting the
requirements of chapter i9.28 RCW to perform plumbing
work that is incidentally, directly, and immediately
appropriate to the like-in-kind replacement of a household
appliance or other small household utilization equipment
that requires limited electric power and limited waste
and/or water connections. An electrical trainee must be
supervised by a certified electrician while performing
piumbing work.
' Per Washington State Department of Labor and Industries lessee has
been interpreted to be equivalent to owner for purposes of exemptions.
.. ,
�
I� _...r-r-
.�_. � _�- /
�
� �
� r,,,,....-
.�-
�
� V /
.f f ��
�-~--" /
� ��,� � , -/�
\ . � � . C� \ � _,,..�
\�N . : :. � : �. � � � � /..r--
� ��$ . . . . � . �,,,,�---
� �� ������.������.���.��. �. � y
rP \ N��..,
\� . ' . ' . ' . \ I
\ \ �,f ~
\ � � � �- �1"0' WIDE BIKE/PEDESTRIAN
\ \ � �� � � PATH
\ � � --- '""
� . . . . . � � �, _.._.
� � � � � . . �..�. � .�. � � � , � ._,,,�,_
� � ......... �.
� � � � :�.�.�.:��..� � � � , .._-��
, \ � � \ �. �. �. � � � � _„�..�--''
\ \ � � \ �. . . � � _ \ -�""_
\ \ � � \ .. . ..�.�� �. , � �� �..��. � -'"
\ � � \ \ \ ...,... . . � �� \ /....
\ � � �. � . �, . , � . � _...../ �-_"
� � � � � ��.���.��� �.� � \ ` �
� � .... . �
� � � � ` �'
\ \ \ � \ ,,� . �. � . \ \ \ ....--
\
� � � � � � � �� . . �, . :. �,:. � � � � .
� � �\ � � � � � .. ..:..�.......... � � �
\ \ \ \ C� . �. .. �.��. �\
� � \ � � � � \ � � ����..��.�..� .�,��� . ; f-�'""�
� � \ � \ \ r'� � � . .� . . \ � ; \
� � \ � �� � \ � . . �` �
�' � � �
\ � � � r- ��_.. \ � \ � � . . . � . �, ���
\ \ � \ � � �� � � \ � . ����.�� ��� .�� �� . �Q��g �
� � � _ ` �``� ,._....J � \ � � . . �. . . � . . � � `60�� � �,.r
..,r� _ � o.�� 5-t
\ � f . �:.� �� \ � \ � � � � Q� �,. . \
f,---��--?. � � � � � � � �� � . �� \
�..�--�' � � � � • . ' �
/�.� � � �.�� � \ � \ \ \ � �
w.� C�� � � � \ � \
�-, `._ \ \ \ \ � , . , � �
�....� � \ � � � � � � . �� �.�� � \
\ \ \ � � � � � \ \/ _� � � . . . �.
/ \
\ � � \ � \ � \ ���J .�.� .� � .�. \
\ � � \ � \ � \ �-'� � �. �. � � . \
\ \ \ � � � � � �� \ . �
� \
� \ \ � � � � � � \ , �
w � � . .' �
o \ � \ \ \ � � . . ,
� � � � , � , � , � � _ �.�. �. . �. � � . .
Q
�
Y RA P PLAN
�
�' TAX PARCEL NU��ER 1 "=10�-0��
� HORIZONTAL GRAPHIC SCALE
z 3623049087 10 5 0 5 10
�
0
J CONTACTS 1 inch = 10 ft.
� APPLICAfVT� CIVIL ENGINEER�
�
a KIEN NGUYEN PBG, LLC
� 6801 S. 180TH STREET 5130 S. 166TH LANES
�
� TU KW I LA, WA 98188 S EATAC, WA 98188
(253) 951-6449 (206) 229-6422
� EMAIL: KIENKHAM@GMAIL.COM CONTACT: HAN PHAN, P.E.
U
L
�
�
� �� �
�
D ������ ��. . � � D��_( q �O
�
�
i FI��; ��'�iri4s,� :�����aw��! i� �ut�j��t to �►7'��'s a►�d �noi��i���.
� ;t .-,.. ., x • �
o �'_r.���i.�,�:�=1.! i�l �'aPt�i'�i�ti�:ti�+fi i"if3%l6PYT�i�f'3 i���3 l�t5i �4�h�€}j'l�.�
� �f1f� ��i�l������;,; t;�i t�.���a�� �c���t�€� ��cf� �� ��din�nc�. ����i��
�
J ofi £�p��c��f�;,� �=i�1d ��� d �car����e�rt� i� �elcnowiec����1:
� ��,: .
o .
o Q�18: � �C`� �
� ._' `".�..
0
_ , , �rl�j/ Q� ��1�l�VI��
BUILDIi�G DIVISI��
E
a
rn
r� �
N '
I �cD
". Know what's below.
�
_ �111 before you dig.
�
�
8' WIDE TEMPORARY RAMP
r" -""�
/",
__,,...
`
CONT. 2X4 TOP RAIL
2X2 VERT. � 4" O.C.
WOOD 4X4 � 6'-0"-
O.C. UON.
CONT. 2X4 BOTTOM RAIL-
2X4 ANGLE BRACE•
4X4 BOTTOM
RAIL. PIN TO
ASPHALT
` �����.l�i°�aa "- ��ek`�'� 3< ,';r� ��"� .___._.
.. ._ . -:: . , . � , f - . . / a �Y.
�I�? �h�.c�t��� t�,F��i ��;� �,�€� � '. �� �����
pf�s�� wi�hc�r.at �.��r��a! ���� ���
����nin� �►;�i�i�r� og d���
� w
► �i����ov�d .�y: �-- �
; �``�•a�: `�7
� ,£:,., _
.:. ...„ �
' I
� ��
1Y"
_Z
CLR.
+
+
1 1 /2" DIA.
HANDRAIL
HANDRAIL
BRACKET � 48"
O.C., TYP.
�- . � - �� - � - �- . ��
.
�
.�,- -:•. _►� �
NOTE 1. TEMPORARY RAMP TO BE REMOVED BY
SEPTEMBER 1 ST, 2016. CONTRACTOR /
4WNER SHALL RESTORE IN KIND ANY
DAMAGE AREA TC� THE LEVEE SIDE SLOPE
WITH SOD.
�
�t �` �'%'� �
t'
1 i�t� �,�u�
rt `�� �y#isr d k s,t,v,�4 t��rl �y¢„,
�o��i i "��7yr
,����tt������ �t�j���{� �
2X4 TOP RAI
MAX. SPACING
4" SPHERE
2X2 VERT. � 'Tn D.0
TYP.
WOOD 4X4 � 6'-0'
O.C. UON.
EL=34.90
BIKE/PEDESTRIAN PATH
3/4" PLYW001
SHEATHINf
OVER 2X8 J01:
� 16" C
2X4 BOTTOM RAII
1'-2"
1'-0"
(2)2X8 HF #1
EDGE JOIST
(2)-�"� MIN
THRU BOLTS/
EACH GUARDF
TEMP. RAMP LOCATION
sE� �o-rE 1
�d
. , � � ,,, �;,, �,.
��,\�,} �-f, �'�,.',��-`,r"'•.i'' � � :.~L`..�
�,�+�y, \ `�`,`\'��� -y+*,� ...�� r '�/� w~K}~.
.. ,,
, , � •, , � _.._.._.�. , , � �}
���' , -�;;; ;-• w ���.�•�'' ; , � �_
,...-,,: " ..,
r�"___._...._...�.� ,..--� ��,
(��,,,,/� ';;
E = ,r��\\
" y � ... P.t4it£1. � �
�1
�
� �-� �
� ��.
�E� ��P
NTS
REFERENCE
SHEET N0.
��
SHEET
1
OF
1
SHEETS
�____ �EVISIONS �
No ch�ng�s shall b� m�zde to the scopP
of �varlc ���i#hot.,t prior � ��rov�f of
r t,4±r.•ril� Buildinc� Divi$i�n.
P�'�Ti �: r��visio�, 4vi11 require a n���v p!an submittal
and may inc,ud� �dditionai plGn revi��rr f��s. �
� �-����
���
� �`
���( \
�,
SIDES WITH 2X4 BRACING AS SHOWN
��'i�C♦7�\��I�:i=3��Z7:�
�
EXISTING ASPHALT PARKING LOT
RA f CR0�7S �7GCT�o�
1 "=1'-0"
33'-6"
8' WIDE RAMP:
3/4" PLYWOOD SHEATHING
(2) 2X8 H.F. #1 EDGE JOISTS
2X8 H.F. #1 JOISTS @ 16" O.C.
SIMPSON JST. HANGERS, TYP.
`
17.00% SLOPE
��--- �u--- ----�-- ��
EX. ASPHALT PARKING LOT
TYP POST FRAME � 6' O.C.
4X4 POSTS W/ PIER BLOCK
POST CAP CONNECTOR @ TOPS
DBL 2X8 HF #1 BM UNDER SHEATHING
2X4'X' CROSS BRACING
RAMP PROFILE
%a"=1'-0,�
1'-0"
1'-2"
o �
z � � �
Oei' o>- o z
�w m W �
�z
� U �
� � V d
�HANDRAIL TURNS INWARD O
AND RETURNS TO POST (TYP) �
@ END POST. SEE DETAIL a
�
U
u�
w
0
EL=29.20 Z
0
�
-------------- w
---- �
�
PROVIDE 50LID BLOCKING 6' O/C
WHERE SPACE UNDER RAMP DOES
NOT ALLOW FOR TYPICAL POST
FRAME WITH X BRACING
� ^k: � g
i �
fi '
� � i..c„:>,,{Y
Z E 4.
� t �
3 ;
E
W
Q
0
0
z
���,nr
� � � �
Y �
i�� � t
M1 ^
Yg w,��a
,�r�a;.a�:x�: �( ta � � �t �d '�1
`; , % -w�;n. r � "�'$�
s � �
�
� _CEIVED
dl � TUKINIl.A
JUL 19 2016
PERMIT CCNTEFt
�