Loading...
HomeMy WebLinkAboutPermit D16-0198 - BURLINGTON COAT FACTORY - STORAGE RACKSBURLINGTON COAT FACTORY 17 4 8 0 S O UTH C ENTER PK D 16-0198 � � City of Tukwila • Department of Community Development • 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 ' `' Phone: 206-431-3670 Inspection Request Line: 206-438-9350 Web site: http://www.TukwilaWA.gov DEVELOPMENT PERMIT Parcel No: 2623049110 Address: 17480 SOUTHCENTER PKWY Project Name: BURLINGTON COAT FACTORY Owner: Name: KIR TUKWILA OSO LLC Address: 3333 NEW HYDE PARK RD #100 C/0 KIMCO REALTY CORP, PO BOX 5020 NEW HYDE PK, CA, 11042 Contact Person: Name: DAVID GLASSMAN Address: Contractor: Name: 1309 POST AVE , TORRANCE, CA, 90501 ALEGIS RESTORATION INC Address: 3701 S NORFOLK ST, SUITE 300 , SEATTLE, WA, 98118 License No: ALEGIR1890K6 Lender: Name: KIMCO REALTY Permit Number: D16-0198 Issue Date: 8/3/2016 Permit Expires On: 1/30/2017 Phone: (310) 781-8250 Phone: (206) 725-0385 Expiration Date: 5/19/2017 Address: 4065 FACTORIA MALL, BELLEVUE, WA, 98006 DESCRIPTION OF WORK: INSTALLATION OF SHELVING FIXTURES FOR BURLINGTON COAT FACTORY (RETAIL CLOTHING STORE). THE TENANT IMPROVEMENT PERMIT IS SEPARATE AND ALREADY APPROVED UNDER PERMIT D16-0011 Project Valuation: $57,000.00 Fees Collected: $1,802.16 Type of Fire Protection: Sprinklers: YES Fire Alarm: YES Type of Construction: VB Occupancy per IBC: M Electrical Service Provided by: TUKWILA Water District: HIGHLINE,TUKWILA Sewer District: TUKWILA Current Codes adopted by the City of Tukwila: International Building Code Edition: 2015 National Electrical Code: 2014 International Residential Code Edition: 2015 WA Cities Electrical Code: 2014 International Mechanical Code Edition: 2015 WAC 296-46B: 2014 Uniform Plumbing Code Edition: 2015 WA State Energy Code: 2015 International Fuel Gas Code: 2015 Public Works Activities: Channelization/Striping: Curb Cut/Access/Sidewalk: Fire Loop Hydrant: Flood Control Zone: Hauling/Oversize Load: Land Altering: Landscape Irrigation: Sanitary Side Sewer: Sewer Main Extension: Storm Drainage: Street Use: Water Main Extension: Volumes: Cut: 0 Fiil: 0 Number: 0 �: Water Meter: No � Permit Center Authorized Si nature: �� W "" F� I Date: g I hearby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this development permit and agree to the conditio, s attached to this permit. Signature: �� ���'�- —� Print Name: k�--� � � ��5� ° Date: � � This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 4: The total number of fire extinguishers required for an ordinary hazard occupancy with Class A fire hazards is calculated at one extinguisher for each 1,500 sq. ft. of area. The extinguisher(s) should be of the "Ail Purpose" (3A, 40B:C) dry chemical type. Travel distance to any fire extinguisher must be 75' or less. (IFC 906.3) (NFPA 10, 5.4) 1: Portable fire extinguishers, not housed in cabinets, shall be installed on the hangers or brackets supplied. Hangers or brackets shall be securely anchored to the mounting surface in accordance with the manufacturer's installation instructions. Portable fire extinguishers having a gross weight not exceeding 40 pounds (18 kg) shall be installed so that its top is not more than S feet (1524 mm) above the floor. Hand- held portable fire extinguishers having a gross weight exceeding 40 pounds (18 kg) shall be installed so that its top is not more than 3.5 feet (1067 mm) above the floor. The clearance between the floor and the bottom of the installed hand-held extinguishers shall not be less than 4 inches (102 mm). (IFC 906.7 and IFC 906.9) 2: Extinguishers shall be located in conspicuous locations where they will be readily accessible and immediately available for use. These locations shall be along normal paths of travel, unless the fire code official determines that the hazard posed indicates the need for placement away from normal paths of travel. (IFC 906.5) 3: Fire extinguishers require monthly and yearly inspections. They must have a tag or label securely attached that indicates the month and year that the inspection was performed and shall identify the company or person performing the service. Every six years stored pressure extinguishers shall be emptied and subjected to the applicable recharge procedures. If the required monthly and yearly inspections of the fire extinguisher(s) are not accomplished or the inspection tag is not completed, a reputable fire extinguisher service company will be required to conduct these required surveys. (NFPA 10, 7.2, 7.3) 5: Maintain fire extinguisher coverage throughout. 7: Sprinklers shall be installed under fixed obstructions over 4 feet (1.2 m) wide. (NFPA 13-8.6.5.3.3) 6: All new sprinkler systems and all modifications to existing sprinkler systems shall have fire department review and approval'of drawings prior to installation or modification. New sprinkler systems and all modifications to sprinkler systems involving more than SO heads shall have the written approval of Factory Mutual or any fire protection engineer licensed by the State of Washington and approved by the Fire Marshal prior to submittal to the Tukwila Fire Prevention Bureau. No sprinkler work shall commence without approved drawings. (City Ordinance No. 2436). 10: Maintain fire alarm system audible/visual notification. Addition/relocation of walls or partitions may require relocation and/or addition of audible/visual notification devices. (City Ordinance #2437) 9: All new fire alarm systems or modifications to existing systems shall have the written approval of The Tukwila Fire Prevention Bureau. No work shall commence until a fire department permit has been obtained. (City Ordinance #2437) (IFC 901.2) 11: Clearance between ignition sources, such as light fixtures, heaters and flame-producing devices, and combustible materials shall be maintained in an approved manner. (IFC 305.1) 12: Where storage height exceeds 15 feet and ceiling sprinklers only are installed, fire protection by one of the following methods is required for steel building columns located within racks: (a) one-hour fire proofing, (b) sidewall sprinkler at the 15 foot elevation of the column, (c) ceiling sprinkler density minimums as determined by the Tukwila Fire Prevention Bureau. (NFPA 13-16.1.4) 13: Storage shall be maintained 2 feet or more below the ceiling in nonsprinklered areas of buildings or a minimum of 18 inches below sprinkler head deflectors in sprinklered areas of buildings. (IFC 315.3.1) 14: Flue spaces shall be provided in accordance with International Fire Code Table 3208.3. Required flue spaces shall be maintained. 8: Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (City Ordinances #2436 and #2437) 15: Any overlooked hazardous condition and/or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. 16: These plans were reviewed by Inspector 511. If you have any questions, please call Tukwila Fire Prevention Bureauat(206)575-4407. 17: ***BUILDIN6 PERMIT CONDITIONS*** 18: Work shall be installed in accordance with the approved construction documents, and any changes made during construction that are not in accordance with the approved construction documents shall be resubmitted for approval. 19: All permits, inspection record card and approved construction documents shall be kept at the site of work and shall be open to inspection by the Building Inspector until final inspection approval is granted. 20: When special inspection is required, either the owner or the registered design professional in responsible charge, shall employ a special inspection agency and notify the Building Official of the appointment prior to the first building inspection. The special inspector shall furnish inspection reports to the Building Official in a timely manner. 21: A final report documenting required special inspections and correction of any discrepancies noted in the inspections shall be submitted to the Building Official. The final inspection report shall be prepared by the approved special inspection agency and shall be submitted to the Building Official prior to and as a condition of final inspection approval. 22: All construction shall be done in conformance with the Washington State Building Code and the Washington State Energy Code. 23: There shall be no occupancy of a building until final inspection has been completed and approved by Tukwila building inspector. No exception. 24: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center. 25: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. PERMIT INSPECTIONS REqUIRED Permit Inspection Line: (206) 438-9350 1700 BUILDING FINAL** 1400 FIRE FINAL 4046 SI-EPDXY/EXP CONC Co �an� ��ry De�� me� Depnrtment Public Works Department Permit Ce�7ler 6300 Soulhcenler Bh-d., Suite 100 Tukvila, Id�A 98/88 http://www.TukwilaW A.gov Building Permit No. �(� Project No. Date Application Accepted: `J V�� � Date Application Expires: L��d'�� 7 , o�� o��ice use CONSTRUCTION PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **Please Print** SITE LOCATION King Co Assessor's Tax No.: oZ6�=, ��1 �( ! V Site Address: l� Suite Number: Floor: .�- Tenant Name: New Tenant: �.....Yes ❑ ..No GENERAL CONTRACTOR INFORMATION Company Name: Address: City: State: Zip: Phone: Fax: Contr Reg No.: Exp Date: Tukwila Business License No.: LENDER/BOND 1SSUED (required for projects $5,000 or greater per RCW 19.27.095) Name: �� l �GG �'Z �G� � Address Ll��� � u G� v��� �� ���� _ City: /j_���v� State:�/� _ Zip: ��Gp� H:Wpplications�Forms-Applications On Line�201 I Applica�ions�Permit App�ication Revised - 8-9-1 I.docx Revised: August 201 I Page 1 of 4 bh y , . 9 BUILDING PERMIT INFORMATIUN — 206-431-3G70 ��� .• Valuation of Project (contractor's bid price): $�(%(%� Existing Building Valuation: $ Describe the s ope of work (please provide detailed in ormation): t f� � S"�1 � ��1 �C 0 � o � �(v � h �i �C�r-1 S -�,� �ur I I'� y�U�1 �I� � �"� � '�?� � I .�' � .c h� 0. G� �C� c[ �i p/�re � uvt �Cir'. c��� �� s-b �-�. ) . � �; T� �e ��� �-- +� s�P r �( I � �C �C � ����-�� �b-ovf! � _. Will there be new rack storage? ��...Yes ❑.. No ]f yes, a separate permit and plan submittal will be required. Provide All Building Areas in Square Footage Below Addition to Type of Type of Existing Construction per Occupa�icy per Existin Interior Remodel Structure New 1BC 1BC 1�' Floor G( � � � in 2" Floor 3 Ploor Floors thni Basement Accessory Structure* Attached Garage Detached Garage Attached Carport Detached Carport Covered Deck Uncovered Deck PLANNING DIVISION: Single family building footprint (area of the foundation of all stru tures, plus any decks over ] 8 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: ��� �(��� ��I�,,,� G� "" 7 L,ot Area (sq ft): Floor area of pnncipal dwelling: Ploor area of accessory d���elling: 'Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact: Handicap: Wil( there be a change in use? ❑....... Yes �]....... No If "yes", explain: FIRE PROTECTION/HAZARDOUS MATERIALS:/ �....... Sprinklers �....... Automatic Fire Alarrn ❑ .......None ❑ .......Other (specify) Will [here be storage or use of flammable, combustible or hazardous materials in the building? ❑.......Yes �]C �.......No If "yes', atlach /ist of materlals and storage locations on a separate 8-1/2"x 11 " paper rnc/uding quantities and Material Safet�� Data S/leets. SEPTIC SYSTEM ❑.......On-site Septic System — For on-site septic system, provide 2 copies of a current septic design approved by King County Health Department. H:Wpplitatiortt�Forrttt-Appiications On Line�20ll Applications�Permit Applitation Revised - 8-9-1 l.docz Revised: Augusl 201 I Page 2 of 4 PERMIT APPLICATION NOTES — • . Value of Construction — In all cases; a value of construction amount should be entered by the applicant. This figure �vill be revie�ved and is subject to possible revision by the Permit Center to comply �vith current fee schedules. Ezpiration of Plan Rcvie�v — Applications for tifiich no pemiit is issued �vithin 180 days following the date of application shall expire by limitation. The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section ]05.3.2 International Building Code (current edition). ] HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW TH� SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OP THG STATE OF WASH]NGTON, AND I AM AUTHORI7ED TO APPLY FOR THIS PERMIT. BUILDING Signature:_ Print Name Mailing Ad ZED AGEN7': Date: � � Day Telephone:���'/�'g/ �� %C � c�ry H:V+pplications\For�-Applications On Line�2011 Applications�Permit Application Re��sed - 8-9-I I.docx Revised: August 2011 bh � �— Statc Zip Page 4 of' 4 �� PUBLIC WORKS PERMIT INFORMATION — 206-433-0179 Scope of \�Jork (please provide detailed information): Call before you Dig: 811 Please refer to Public Works Bulletin 1 for fees and estimate sheet. Water District ❑ ...Tukwila ❑... Water District #1 ❑ ...Water Availability Provided Se���er District ❑ ...Tukwila ❑ ... I ley V iew ❑ ...Se�ver Use Certificate ❑...Se� r Avail� � ■Q ❑ .. Renton ❑ .. Seattle Sentic Svstem: � ❑ On-site Septic System — For on-site septic s em, provide 2 copies of uttent septic design approved by King County Health Department. Submitted with A lication mark boxes which a ❑...Civil Plans (Maximum Paper Size — 22" x 34") ❑...Technical Information Report (Storm Drainage) ❑.. Geotechnical Report ❑...Traffic Impact Analysis ❑ ...Bond ❑ .. Insarance ❑ .. Easemen ❑ .. Maintenance Agreement(s) ❑ ...1-�old Narmless — (SAO) ❑...Hold Harmless—(ROW) Pronosed Activities (mark boxes that apnlvl: ❑...Right-of-way Use - Nonprofit for less than 72 ho s .. Right-of-way Use - Profit for less than 72 hours ❑...Right-of-way Use - No Disturbance Right-of-�vay Use — Potential Disturbance ❑ ...Construction/Excavation/Fill - Right-of-way Non Right-o way ❑ ❑ ...Total Cut cubic yards ❑ ...Total Fill cubic yards ❑ .. Work � Flood Zone ❑ .. Storm D ioage ❑...Sanitary Side Sewer ❑.. Abar�don Septic Tank ❑...Cap or Remove Utilities ❑.. Curb Cut ❑ ...Frontage Improvements ❑ .. Pavement Cut ❑ ...Traffic Control ❑ .. Looped Fire Line ❑ ...Backflow Prevention - Fire otection " Im ation " D mestic Water �� ❑ ...Permanent Water Mete Size... " WO # ❑ ...Temporary Water Meter Size .. ' WO # ❑ ...Water Only Meter Size............ " WO # ❑ ...Sewer Main Extension .............Public ❑ Private ❑ ❑ ...Water Main Extension .............Public ❑ Private ❑ ❑ .. Grease Interceptor ❑ .. Channelization ❑ .. Trench Excavation ❑ .. Utility Undergrounding ❑...Deduct Water Meter Size " FINANCE INFORMATION Fire Line Size at Property Line Number of Public Fire Hydrant(s) ❑ ...Water ❑ ...Se�ver ❑ ...Sewage Treatment Monthlv Service Billine to: Name: Day Telephone: Mailing Address: Ciry State 7.ip Water Meter Refund/BillinQ: Name: Day Telephone: Mailing Address: City H:Wpplications�For�•Applications On Line�201 I ApplicntionsU'ermit Application Revised - 8-9-1 �.docx Revised: Augu512011 bh State Zip Page 3 of 4 Date Paid: Wednesday, August 03, 2016 Paid By: BURLINGTON STORES Pay Method: CREDIT CARD 040735 Printed: Wednesday, August 03, 2016 2:52 PM 1 of 1 ��� SYS7EM5 Date Paid: Wednesday, July 20, 2016 Paid By: GLASSMAN PLANNING ASSOCIATES i Pay Method: CHECK 2189 Printed: Wednesday,luly 20, 2016 10:44 AM 1 of 1 ���� SY57Eiv15 � INSPECTION RECORD Retain a copy with permit b�6� � r�p INSPECTION N0. PERMIT N0. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 � Appr�oved per applicable codes. � Corrections required prior to approval. COMMENTS: 3LC -�''T" �� � �� .��- ,� Inspector: Date: 1� /� L I I KtINSPtGI10N FtE h�EQUIKED. Nrior to next inspection, tee must be u paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION RECORD -- C�c��_ � Retain a copy with permit �,(� -� � � � �✓ � .�� -� �-- � � INSPECTION NUMBER ��, p�RMIT�NUMBERS r ,�� CITY OF TUKWILA FIRE DEPARTMENT �nti-���-4am , Projec � Type of Inspectian: � - t �i,..��^--�,. �v � r` Address Contact Person: � Suite #: c,.� � ,,,,,, �/�-c (,�... Special Instructions , Phone No.: �Approved per applicable codes. � Corrections required prior to approval. COMMENTS: � � �.� r.�--t " � �.,.�., �--- �' , �- � � � n-�� � --- � S� - ��l��- -G --� �'�.; „ � ,� j--- � �-.... °� -�-�� � �.--�-� Needs Shift Inspection: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre-Fire: Permits: Occu anc T e: , r: Date: �'�j�,/f� � Hrs.: � � �$100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. Billin Address Attn: Company Name: Address: City: State: Word/Inspection Record Form.Doc 3/14/14 T.F.D. Form F.P. 113 �'" . �. Materials Testing & Consulting, Inc. Geotechnical Engineering & Consulting � Special Inspection � Materials Testing � Environmental Consulting August l 7, 2016 Ron Tabish Burlington Coat Factory 4827 Route 130 South Edgewater Park, NJ 08010 S21Zt VZR 2Y12QIl: ron.tabish@budingtonstores.com Re: Final Letter Burlington Coat Factory - Tukwila 17480 South Center Pkwy Tukwila, WA MTC Project #] 6B 154 BLDG Permit #D16-0198 Dear Mr. Tabish: Materials Testing & Consulting, Inc. (MTC) provided materials testing and special i�spection services during construction of the above-referenced project. This letter is a statement declaring the actual work inspected by MTC itemized below was found to be, to the best of the inspector's knowledge, in accordance with project plans, specifications, engineer approved revisions, and the International B�i�ing���c�Cl�a The following is the scope of inspections performed on this project: �m�� �'� TU!{�/ILf� ♦ Proprietary Anchors ����5� � � �0�� ���NIfT C;E��TER The results of our services were provided to the local building department for review. Only WABO Certified special inspectors were utilized to perform those specific inspections as reyuired by the Special Inspection Agreement. Any items that were found to be in noncompliance with the approved construction documents were repaired or replaced, and re-inspected for acceptance. To the best of our knowledge, items that were observed by Materials Testing & Consulting, Inc. during continuous or part time inspections for the noted project are compliant with approved plans and specifications. Page 1 of 2 I � 0�� �\ Corporate • 777 Chrysler Drive • Burlington, WA 98233 • Phone 360.7 5.1990 • Fax 360.755.1980 SW Region • 2118 Black Lake Blvd. S.W.• Olympia, WA 98512 • Phone 360.534.9777 • Fax 360.534.9779 NW Region • 805 Dupont St, Suite 5• Bellingham, WA 98226 • Phone 360.647.6061 • Pax 360.647.8111 Kitsap Region • 5451 N.W. Newberry Hill Road, Suite ]O1 • Silverdale, WA 98383 • Phone 360.698.6787 • Fax 360.692.1919 Visit our website: ���i��.mtc-inc.net r�'" . . ! 1l�Ia er�a�s Testing c� Consultin�, Inc. Geotechnical Engineering & Consulting � Special Inspection � Materials Testing � Environmental Consulting LIMITATIONS The services provided as described in this report include professional opinions and judgment based on the data collected and our field observations. These services have been performed according to the specified codes, industry standards, and generally accepted engineering practices. No warranty, express or implied, is provided. Representatives of Materials Testing & Consulting, Inc. did not supervise, direct, alter, amend or change project specifications or contractor activiry. Our statement of conformance pertains to only those items inspected and tested by Materials Testing & Consulting, Inc. for the subject project during the time period when we were on-site. This report may be used only by the client and only for the purposes stated, within a reasonable time from its issuance. Any party other than the client who wishes to use this report shall notify Materials Testing & Consulting, Inc. of such intended use. Based on the intended use of the report, Materials Testing & Consulting, Inc. may require that additional work be performed and that an updated report be issued. Non-compliance with any of these reguirements by the client or anyone else will release Materials Testing & Consulting, Inc. from any liabiliry resulting from the use of this report by any unauthorized party. We sincerely appreciate the opportunity to be of service to you on this project and look forward to offering our services again. If you should have any questions concerning this report, please contact the undersigned at your convenience. Respectfully Submitted, MATERIALS TESTING & CONSULTING, INC. w: -� �#� � {,: --- /_ ,�-����� _� . �. _ --- „i � Ross Bichel WABO Technical Director Page 2 of 2 Corporate • 777 Chrysler Drive • Burlington, WA 98233 • Phone 360.755.1990 • Fax 360.755,1980 SW Region • 2118 Black Lake Blvd. S.W.• Olympia, WA 98512 • Phone 360.534.9777 • Fax 360.534.9779 NW Region • 805 Dupont St, Suite 5• Bellingham, WA 98226 • Phone 360.647.6061 • Fax 360.647.8111 Kitsap Region • 5451 N.W. Newberry Hill Road, Suite ]O1 • Silverdale, WA 98383 • Phone 360.698.6787 • Fax 360.692.1919 Visit our website: �m��a��a�.mtc-inc.��et � �_ 1'I��.��r���� �+���in� � �C�r�����i��� �r��� �� , �:r,5s�4c'�+nlril, i:rs�,i+s►el�P,� 1R' Y i�nr���qing r 4�Xie�l �nr��t'irm �?1]!lltei}��s 1'�atr�g f F.nrirnnRf!'nl�l �r,�nyilli� t `'"+� n�c•�+''��. Fi a�yrr.�nvl �laanrnn�x .S�n � J a.5i _ Burlington Coat Factory - Tukwila -166154 - Proprietary Anchors: Report #P13668 CLIENT Burlington Stores DATE 08/l7/2016 PROJECT LOCATION 17480 South Center Parkway PFRMIT # D16-0198 Tukwila WA Inspection Information: lnspection Date: �8/17/2016 Time Onsite: 06:00 AM Weather C'onditions: Clear Inspcction Performed: Field Data: Base Material: � Concrete "I�hickness in ioches: Proprietary Anchors l:xisting Specified Compressive Strength in psi: Lxis[ing Hole Data in inches: Depth: 4" Edge Distance: Na End Uis[ance: Uiameter: 3/8" Spacin�: �-8. O Clean O llrillcd O Cored Mechanical Anchor Data: ryu�: }i;ir; xri-Fz Length in inches: 4" lliameter in inchex: 3/8 Torqoe (rt. Ibs.): 40 ❑ Setfing'1'oo( Present Adhesive Anchor Data: Product \ame: I.,ocation: Number ot'anchors: � '1'hreaded Rod Anc6or Length in Inches: B�tch #: tixp. Date / Shelf 1_,ife: Anchor Diameter in Inches: Rcmark5: MTC onsite as requested to inspect previously installed anchor bolls. M7'C inspected a re�resentat,ive satnple of bolts which �vere fi�und to be of the correct ryne and ti�htened wit�hin the reqaired torque value (40 fooUlbs) noted on the I�SR report. Bolcs were in compliance to project plans. Images: a.i�.�..rr�.r�..,..�t..�. � e.,....cv��.�.,. �..c..,,�, ..:...: ����� naxr,....F:sie, tPv.s�.e�ax.M1-.rra+.-�•, .a�. .....t:..��.�.,.�.ar..�.�..a+..�...a..:.'.n � r.. .l:� �_ . .i,(.n ,. '...I.a�.-E•. x ntr..e ' ..�.�� ..il?� 4.r, ��i. � .��€ Y��: i ;..1 . .. ';tl �.;k . . ._1 f°r�P�neyie *}:r? 4��rrclrr 17rLti•�r • I�u,����ny�lam. i4`,i 4���4 * WWnn�� ��t�ip.��S_I§+�11 • F`3x .�bt�.?5�.9+dM�! w#\' Rr�tdrn •:I.;`: H€aCa I.�tw H:i'•:1 :ti 54' •1}IpcSirlA� t1'�i'�lyi:= • F'h.=.-n�7 :fP�{I.S:!4.�f";�'� � 3-:ih .it,t,l.°.±A.4�;7'J i�i�5' �it•�jl�tn + �:dli li�i4�q��i1 :4C:t•rl� �uj(;,: 5 • 11�.:111,-s[;liiiii�, }A.,'4 "�}{ �?.+, � k'G.:�I¢ �!�41.f>a`.it:11�I 4 J•:�4 <t+l!.feart,!il 1 t �'.si: rur �n�rhsiic: �• � .���,,;���;, Burlington Coat Faclory - Tukwiln - 76BI54, 08/17/2016, #P13668, Page 1 oj1 � Ty ���+�r��.�� �'`+��tin�� � +��►n�u��i���, In�� f:a�n�tniral i'eq�i�ran� 7l Cnn+ut4tink s 4�+rinl �n+pra�ti��n +\Iwlpristiv Tt+hn� r F'ntiin�nmrnl:�l [',vr�c�dl� t'.qYaTrs�n7i' .l yy urnn�x .S�nne ! 4n! [1Pl_.OAD�D: 08,'17'2016 0?:02:t10 UYLOAllFll: 08i17i?016 07:03:00 �?PLOr�DED: �8I17/?O16 O�:Oti:00 KI�:POR'17f1� l31'_ �1il:c Fin�inttn RLVII�\,'�'I�:D I3Y. R.��mond ti1cl�an7ara_ Pr«jrct n1.u7a�cr ,,..F.r ...... .. .. . ..r, .-.: , .,.,t ,...,..: .,. .,, . ,.;_, ,.,. . ._ ,..z , .,,.m , „r... ..,._ . . . r .,..., :.,....,,. _,....., .. ,.:.. _,� „. . Cr�rpneaEr •'�'�'7 1�3erslr�r flrirr • kutl;n�l�n, 14 A 9li2_1.N � Pltr�sr _�fi1M_1S?_l441F • k'3s �6i�.7��.i4KD �lY I��}�ilYt1 • :I';�°� H=�.i Lzle {i��,'.i '� �4` � ilf'.;���:i.i. 5\ •�. �•lr4'h's � t'h.^.u�� .it�'.� w4a •i"' • Fai St,�,L'� �-1 .��:'.,�a ;�ii� �iC�,i��o ' K?ii 17n�-�srnl w�'¢cl SaeCr 5• N,t:li ;�'Ir.iu�. 'J. 'y �J?i='" ' F"P�.:r€� it.;i &-1'��` r�;if�i • S�ax .�T��f.f�a�" 41 I; `.' �.i: , �ir u:h�.i:u , t�. : . ,: Burlinglon Coa! Factory - Tukwila - 16B154, 08/17/1076, #P13668, Page 2 of 2 STRUCTURAL DESIGN CALCULATIONS For Seismic Shelving Analysis �':: �° � �, .� Burlington Coat Tukwila, WA REVIEWED FOR , CAD� CC?MPLIANCE Q►�P�ON�D AUG Q �. 20�� Ci� c�'it�i�ril� � BUlLDIf�C� i�6�/t���►� � � AMBROSE ENGINEERING INCORPOR.ATED N215 COMMERCE CT., CEDARBURG, WI 53012 PH. [262] 377-7602, FAX [262] 377-4868 ambeng@ambeng.com Job # 016-260 June 14, 2016 Calculations prepared for MEG\�/" hlerchandising Equipman. Group, LLC RECEIVED CITY OF TtJKWILA JUL 20 2016 Merchandising Equipment Group, LLC 502 South Green Street Cambridge City, IN 47327-0240 (765) 478-3141 www.megfixtures.com ER . � � . h�,' �� � �.... .. �w} :Y _-,� ti..�•-�- '•s ,..1 Reference Data These calculations review the design and installation of storage racks for structural adequacy. The sealing of these drawings is for the structural review of the storage racks only. Other information is not reviewed or approved. Building Code C � �C���J • ASCE 7-10 • Rack Manufacturers Institute - Industrial Steel Storage Racks Manual (RMI) Loads Vertical (dead plus live) Stationary Shelving by Merchandising Equipment Group, LLC (MEG Maximum permissible load per shelf < 1171bs Maximum permissible load per unit < 3501bs Component Design Procedure • Structural Analysis based on analyfiical model of one shelving unit only. �g� • Posts/Spreaders designed for double loading to account for back to back or end to end shelf orientations. : :� 'r a w� �.,� � . �, i���, a�a ��^: �•� Aneh�rsfFxacks designed for double loading to account for back to back or end to end shelf orientations. • X�Brace(s) designed for (2) times the loading to account for (1) set of x-braces per (2) units, typical. :���{" i yl j'3. � _ � �.; t. .�. . �ta; �` :i�i3. . .:i ,�,-�a� �� �r ,,�' �, n r.� �i� �'( , 3! . �; � 11 r^` *V �� �Ty,, �. .� �y,plP ? �� : � ',�;� .�. � fi'''�..�` �'�,�;,;> «, ��-,,,, � t � �(� Design Maps Summary Report User-Specified Input euilding Code Reference Document 2012 International Building Code (which utilizes USGS hazard data available in 2008) Site Coordinates 47.44645°N, 122.Z6207°W Site Soil Classification Site Class D-"Stiff Soil" Risk Category I/II/III : � ..._ Z R rts� a r�t : - -�;. `.� - . . � . � �� � �` � J,1�� . ' 1 w,�� 5 i +�" �'' `�t,� � � Rf1��1Tj��O�N � ,�� �MJ2M� • %, �, �. �" I � , a•• •1 . N{{JIf� �d�� � ^�' .. . .t - ' r:� i 'x �� rl��RTt ;i,`.� , A � *��� , i `•* �Uf��`F'1 � _�,.�fiiM �a�?�x r� �., � .' . ; �•,�''M" . ._,.,,: •� `� �:�? � � i'. ' . � � j �.. : 'i::�� ,'Yi , , 'w/�SI'1�G� � --'5����� : �� . . � s� .. ' { �'� ... A � _� '� le � ..,� . ,, , . . y TACOIi�A �VTt - � . , . .� � ��' � �� z A1�EFORT iVdB�?�� �/d�'��'�' •�"�O� s-� D�S_iVi011''�4�5l, � - ��1 - t " � . ' �.! ._ . -y - I j; , .1 { ' �, - �, i �E I'M t � .. _. i � ,s ,� , t � , +�t7�Ylii�OEl � ` �� _ �4r+i9URN _ �� f' � .. 7F� . USGS-Provided Output SS = 1.444 g SMg = 1.444 g Spg = 0.963 g S1 = 0.538 g SM1 = 0.807 g Spi = 0.538 g For information on how the SS and S1 values above have been calculated from probabilistic (risk- targeted) and deterministic ground motions in the direction of maximum horizontal response, please return to the application and select the "2009 NEHRP" building code reference document. MCER Response Spectrum 1.65 1.50 1.35 1.20 1.05 � 0.90 v y O.TS 0.60 0.45 0.30 0.15 0.00 0.00 0.20 O.dO 0.60 0.80 1.00 1.20 1.d0 1.60 1.80 2.00 Period, T (sec) Design Response Spectrum i.io 1.00 0.90 0.80 0.70 0� 0.60 y 0.50 0.40 0.30 0.20 0.10 0.00 0.00 0.20 O.dO 0.60 0.80 1.00 1.20 1.40 1.60 1.80 2.00 Period, T (sec) Although this information is a product of the U.S. Geologica) Survey, we provide no warranty, expressed or implied, as to the accuracy of the data contained therein. This tool is not a substitute for technical subject-matter knowledge. r�AMBROSE ENGINEERING INC. W66 N216 CONIMERCE CT. / CEDARBURG, WI53012 Shelf Information Length � 48 ', m Width 24 �i in Height 144 �in Bottom Shelf "height" 3 in Second Shelf "height" � 91 � in Typical Shelf "height" 88 ; in Number of Shelves 3 Units Laterally Supported 2 Importance Factor lA R,� (braced) � 4 � RZ (unbraced) 3 6 Spl 0.963 Sps 0.538 ' Seismic Design Category D Ca (From RMI) 0.200 Above first floor No Job: Burlington Coat - Tukwila, WA Page: Job #: 016-260 By: Date: 6/14/2016 Checked: Shelf Profile Seismic design pmcedures follow IBC 2012 ASCE 7-1012.8.3,15.5.3, and RMI MH16.1 Seismic Base Shear, V V=CSxIpzWs RMI ASCE 7-10 (min) Cs �R=`�� 0.1345 0.075 CS (R�) 0.08967 Product Load, PL 350 lbs (max load per unit) Cs 0.135 Dead Load, DL 1.5�psf Posts double loaded to account for side to side orientaHan Load per Shelf Load Per Post Dead Load per Shelf Shelf # [lbs] [lba] [lbs] 1 117 5S 12.00 2 117 58 12.00 3 117 58 12.00 Total 350 lbs WS =(0.67 z PL�, x PL) + DL Ws 270.5 lbs V (R�) 36 lbs V (R�) 24 lbs 36 lbs ��AMBROSE ENGIlVEERING INC. Job: Burlington Coat - Tukwila, WA Page: W66 N216 COMMERCE CT. Job tt: 016-260 By: � CEDARBURG, WI53012 Date: 6/14/2016 Checked: Vertical Distribution of Forces Vw hk From RMIMH16.1 F _ x x � x ^ For all levels k 1.0 �W�hk h/d 6.00 �� All shelves loaded to 67% capacity: Posts double loaded to account for side to side orientation Shelf k Load per Shelf Height Post Load (lbs] [in] Modified for # of Racks 1 78 3 39.1 2 78 88 39.1 3 78 144 39.1 Braced Direction (Longitudinal, X) R=4 Load Case 1: All shelves loaded at 67% Shelf # 1 2 3 Total wXhx x [lb-in] 235 6879 11256 18369 lb-in Load Case 2: Top ehelf 100% loaded •al Load at � Level [lbs] 0.5 13.6 22.3 Wa,wP 175 Ibs V�p = F�P 24 Ibs Lateral load af top shelf Each Node [lbs] 0.23 6.81 11.15 � RMS Load Case 1 Load Case 2 ��AMBROSE ENGINEERING INC. Job: Burlington Coat - Tukwila, WA Page: W66 N216 COMMERCE CT. Job Ik: 016-260 By: � CEDARBURG, WI53012 Date: 6/14/2016 Checked: Unbraced Direction (Transverse, Z) R=6 Load Case 1: All shelves loaded at 67% Shelf # W"h"K [lb-in; 1 235 2 6879 3 11256 Total 18369 lb-in Load Case 2: Top shelf 100% loaded Lateral Load at Level [lbs] 0.3 9.1 14.9 Wa,wP 175 lbs V�p = F�p 16 lbs Lateral load at top shelf Specific Load Combinations (per RMI MH16.1 §2.1) Load Factors DL LL (PL) EQ Combination #1 1.00 - - Combination �2 1.00 1.00 - Combination #3 0.75 0.75 -0.50 Combination �4 0.75 0.75 0.50 Combination #5 1.00 0.88 - Member Spreader Beam MII,� 258 in-lb (from RAM) fb 2041 psi Fb 21600 psi f�b 0.094 OK Spreader Beam Connection Rivet Spacing 2 in Rivet Diameter ' 0.1875 in Shear Capacity of Rivet V��,, � 591 lbs VaPP�� IZ% 1175 RIVET OK Each Node [lbs] 0.15 4.54 7.43 Section Properties SX 0.1264'i in3 Fy 3600p' �psi RMS Load Case 1 Load Case 2 V 129 lbs X-Brace - Shelf supports 2 units Axial Force �36 �lbs (for one shelf, spreadsheet multiplies by 2) Ft 14400 psi Area ��_0.0525 _ �in2 fi 1371 psi � BRACE O� � X-Brace Connection to Upright #10 Screw, 18 GA Upright � Va 422 lbs Applied Force 72 lbs .� V„ 591 lbs SCREW OK { � �-� AMBROSE ENGINEERING INC. ! !� W66 N216 COMMERCE CT. � CEDARBURG, 4VI 53012 1 Anchor Diameter 0.375 in Uplifta,� 55 lbs Vm� 135 lbs Interaction 0.0257 ANCHORS OK Slab Information P 214 lbs f � 3000 psi tslab 4 lIl bo 3i lIl F� 29796 lbs A 0.712 ftz Job: Burlington Coat - Tukwila, WA P3ge: Job #: 016-260 By: Date: 6/14/2016 Checked: Anchor Expansion Anchor Hilti Kwik Bolt TZ f� 3000 psi heff 2.5 in T�oW 937 lbs V�o„, 1565 lbs Slab Check i?b = 2.0 for anchorage Base Plate Dimensions b �in w 2.25 in Soil Pressure Under Slab 301 psf < 1000 psf - OK � a �,ow. � � ATTAGNUV(USNTTO ATTnCNMF.M RATE 1V! rtOx�/lI�OI B\ IIEADSAIS .i/� � � � 0,��, � ����a� �:�PONOlES FOR ANGLE COLUMN ANALYSIS, SEE ATTACHED RAM ELEMENTS ANALYSIS COLUMNS ANALYZED IN BOTH DIRECTIONS JLM RMS ICC-ES ESR-1917 r� �-- Ambrose Engineering Inc. Current Date: 6/14/2016 4:53 PM Structural Englneer. Ambrose Engineering Units system: English File name: S:\2016dwg\016-260 MEG - Burlington Coat - Tukwila, WA\Calcs\RAM\016-260 Burlington Coat - Tukwila, WA.etr\ Report: Summary - Group by member Load condiUons to be included in design : c01=DL c02=DL+LLA c03=DL+LLT c04=0.75D L+0.75LLA+0.5EPXA c05=0.75DL+0.75LLA+0.5ENXA c06=0.75D L+0.75LLA+0.5EPXT c07=0.75D L+0.75LLA+0.5E NXT c08=0.75DL+0.75LLA+0.5EPZA c09=0.75DL+0.75LLA+0.5ENZA c10=0.75DL+0.75LLA+0.5EPZT c11=0.75DL+0.75LLA+0.5ENZT c12=0.75D L+0.75LLT+0.5EPXA c13=0.75DL+0.75LLT+0.5ENXA Steei Code Check c14=0.75DL+0.75LLT+0.5EPXT c 15=0.75DL+0.75LLT+0.5ENXT c 16=0.75DL+0.75LLT+0.5EPZA c 17=0.75DL+0.75LLT+0.5ENZA c18=0.75DL+0.75LLT+0.5EPZT c 19=0.75DL+0.75LLT+0.5ENZT c20=0.75DL+0.75LLA+0.5EPXA c21=0.75DL+0.75LLA+0.5ENXA c22=0.75DL+0.75LLA+0.5EPXT c23=0.75DL+0.75LLA+0.5ENXT c24=0.75DL+0.75LLA+0.5EPZA c25=0.75DL+0.75LLA+0.5ENZA c26=0.75DL+0.75LLA+0.5EPZT c27=0.75DL+0.75LLA+0.5ENZT c28=0.75DL+0.75LLT+0.5EPXA c29=0.75DL+0.751LT+0.5ENXA c30=0.75DL+0.75LLT+0.5EPXT c31=0.75DL+0.75LLT+0.5ENXT c32=0.75DL+0.75LLT+0.5EPZA c33=0.75DL+0.75LLT+0.5ENZA c34=0.75DL+0.75LLT+0.5EPZT c35=0.75DL+0.75LLT+0.5ENZT c36=DL+0.88LLA c37=DL+0.88LLT Description Sectlon Member Ctrl Eq. Ratio Status Reference brece RectBar070x.75 65 c13 at 50.00% 0.15 OK Eq. H1-1b 66 c12 at 50.00% 0.15 OK Eq. H1-1 b 67 c13 at 47.92% 0.17 OK Eq. H1-1b 68 C12 at 47.92% 0.17 OK Eq. H1-1 b column sinale rvt bm soreader aIslLU 1.5x1.5x0.0598 LU 1x2 11_16x0B8 a1s/C 1.25x4.5x068 1 c09 at 1.56% 0.90 2 c08 at 1.25°k 0.80 3 c04 at 1.56°�6 0.90 4 c08 at 1.25°� 0.77 7 c05 at 100.00% 0.10 8 c05 at 100.00°k 0.03 18 c13 at 100.00% 0.20 39 c16 at 100.00°r6 0.11 55 C09 at 50.00% 0.18 57 c04 at 100.00°� 0.09 6 32 41 48 49 51 52 54 C05 at 0.00% c13 at 0.00°k c04 at 100.00% C12 at 100.00°� c12 at 0.00°� c12 at 0.00°� c13 at 100.00% c13 at 0.00% 0.06 0.07 0.06 0.07 0.02 0.01 0.02 0.01 OK OK OK OK OK OK OK OK OK OK OK OK OK OK OK OK OK OK C5.2.1-1 C5.2.1-1 C5.2.1-1 C5.2.1-1 Eq. H2-1 Sec. F1 Eq. H2-1 Eq. H2-1 Sec. F1 Sec. F1 C5.2.1-3 C5.2.1-2 C5.2.1-3 C5.2.1-2 C3.3.1-1 C3.3.1-1 {1� � Ambrose Engineering Inc. Current Date: 6/14/2016 4:56 PM Structural Englneer. Ambrose Engineering Units system: English Flle name: S:\2016dwg\016-260 MEG - Burlington Coat - Tukwila, WA\Calcs\RAM\016-260 Burlington Coat - Tukwila, WA.etr\ Steel Code ChecK Report: Concise Members: Hot-rolled Design code: AISC 360-2010 ASD Member . 65 (brace) Design status . OK Sec�ion Information Section name: RectBar 070x.75 (US) Dlmensions , , `���: i u .� . �: ki `: y, a = 0.750 [in] Height b = 0.070 [in] Width Propertfes Section properties Gross area of the section. (Ag) Moment of Inertia (local axes) (I) Moment of Inertia (principal axes) (I') Bending constant for moments (principal a�ds) (J') Radius of gyration (local axes) (r) Radius of gyration (principal axes) (r') Saint-Venar�t torsion constant. (J) Section warping constant. (G1�v) Distance from centroid to shear center (principal axis) (xo,yo) Top elastic section modulus of the section (local axis) (Ssup) Bottom elastic section modulus of the section (local axis) (Sin� Top elastic section modulus of the section (principal a�ds) (S'sup) Bottom elastic section modulus of the section (principal axis) (S'in� Plastic section modulus (local axis) (Z) Plastic section modulus (principal auis) (Z') Polar radius of gyration. (ro) Area for shear (Aw) Torsional constant. (C) Materlal : A570 Gr50 cold form weightless Propertles Yield stress (Fy): Tensile strength (Fu): Unit [in2] [in4] [in4] [in] [in] [in] [in4J [in6) [in] [in3] [in3] [in3] [in3] [in3] [in3] [in] [in2] [in3] unit [Kipfin2j [Kip/in2] Major axls Minor axis 0.053 0.002 2.14E-05 0.002 2.14E-05 0.000 0.000 0.217 0.020 0.217 0.020 8.07E-05 0.000 0.000 0.000 0.007 6.12E-04 0.007 6.12E-04 0.007 6.12E-04 0.007 6.12E-04 0.010 9.19E-04 0.010 9.19E-04 0.217 0.053 0.053 0.011 Value 50.00 65.30 Elasticity Modulus (E): Shear modulus for steel (G): [Kip/in2] 29000.00 [Kip/in2] 11507.94 DESIGN CRITERIA Description Unit Value Length for tension slendemess ratio (L) (ft] 5.48 Distance between member lateral bracing points Length (Lb) [ft] Top Bottom 5.48 5.48 Laterelly unbraced length Length [ft] Effective length factor Major axis(L33) Minor axis(L22) Torsional axis(Lt) Major axis(K33) Minor axis(K22) Torsional axis(Kt) 5.48 5.48 5.48 1.0 1.0 1.0 Additlonal assumptlons Continuous lateral torsional restraint Yes Tension field action No Continuous flexural torsional restraint No Effective length factor value type None Major axis frame type Sway Minor auis frame type Sway DESIGN CHECKS AXIAL TEN310N DESIGN � Axlal tenslon Ratio . 0.02 Capacity . 1.57 [Kip] Reference : Eq. Sec. D2 Demand . 0.03 [Kip] Ctri Eq. : c12 at 0.00% Intermedlate results Unit Value Reference Factored axial tension ca�aciN(Pn/SZ) [Kip] 1.57 Eq. Sec. D2 AXIAL COMPRESSION DESIGN '"!� Comoression in the malor axis 33 Ratio . 0.00 Capacity . 0.09 [IGp] Demand . 0.00 [Kip] Intermedlate results Section classification Factored flexural bucklina strenath(Pn33/S2) Reference Ctrl Eq. Unit [Kip] : Sec. E1 : c05 at 50.00% Value Reference 0.09 Sec. E1 Comoression in the minor axis 22 Ratio . 0.02 Capacity . 0.00 [Kip] Demand . 0.00 [Kip] Intermediate results Section classification Factored flexural bucklina strenath(Pnz2/S2) Reference Ctrl Eq. Unit [Kip] : Sec. E1 : c05 at 50.00% Value Reference 0.00 Sec. E1 FLEXURAL DESIGN � Bendina about maior axis. M33 Ratio . 0.14 Capacity . 0.02 [Kip"ft] Reference : Sec. F1 Demand . 0.00 [Kip"ft] Ctrl Eq. : c13 at 50.00°� Intermediate results Unit Value Reference Section classification Factored vieldina strenath(Mn/Si) [Kip*ft] 0.02 Sec. F1 Bendins� about minor axis. M22 Ratio . 0.01 Capacity . 0.00 [Kip'ft] Reference : Sec. F1 Demand . 0.00 [Kip•ft] Ctrl Eq. : c05 at 46.88% Intermediate results Unit Value Reference Section class�cation Factored vieldina strenath(Mn/S2) [Kip`ft] 0.00 Sec. F1 DESIGN FOR SHEAR Shear In malor axls 33 Ratio . Capacity . Demand . Intermedlate results Factored shear ca�acitv(Vn/SZ) Shear in minor axls 22 Ratio . Capacity . Demand . Intermediate results 0.00 0.94 [Kip] 0.00 [Kip] 0.00 0.94 [Kip] 0.00 [Kip] � Ct�i Eq. : C05 at 0.00% Unit Value Reference [Kip] 0.94 Ctri Eq. : c05 at 50.00% Unit Value Reference 0 Factored shear caoaciN(Vn/SZ) TORSION DESIGN � Torsion Ratio . 0.01 Capacity . 0.00 [Kip"ft] Demand . 0.00 [Kip"ft] Intermediate results Factored torsion caoaciN(Tn/Si) [Kip] Ctrl Eq. Unit �Kip*ft] 0.94 : c04 at 50.00% Value Reference 0.00 COMBINED ACTIONS DESIGN � Combined flexure and axial compresslon ............................................................................................................................................................................. Ratio . 0.14 Ctrl Eq. . c05 at 50.00°r6 Reference : Eq. H1-1b ............................................................................................................................................................................. Intermediate results Unit Value Reference Interaction for doublv svmmetric members for in-olane bendinq — 0.14 Eq. H1-1 b Interaction for doub�y svmmetric members for out-of-olane bendinq — 0.04 Eq. H1-2 Combined flexure and axlal tenslon ............................................................................................................................................................................. Ratio . 0.15 Ctrl Eq. . c05 at 50.00°� Reference : Eq. H1-1b ............................................................................................................................................................................. Intennedlate results Unit Value Reference Combined flexure and axlal compresslon about local axls ............................................................................................................................................................................. Ratio . N/A Ctri Eq. . — Reference . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Combined flexure and axial tenslon about local azls ............................................................................................................................................................................. Ratio . N/A Ctri Eq. . — Reference . ............................................................................................................................................................................. Combined torslon, flexure, shear and aulal compression ............................................................................................................................................................................. Ratio . N/A Ctr1 Eq. . — Reference . ............................................................................................................................................................................. Combined torsion, flexure, shear and axlal tenslon . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Ratio . N/A Ctr1 Eq. . — Reference . ............................................................................................................................................................................. Members: Cold-formed Design code: AISI 2001 Sup. 2004 ASD Member Design status PROPERTIES . 1 (column) . OK Secuon information Section name: aisiLU 1.5x1.5x0.0598 (US) Dimensions ; •:+' ,1; {; a, - ��r. Y. _ : -. . :a ,. a = 1.500 [in] Ftange width r = 1.500 [in] Inside bend radius t = 0.060 [in] Thickness Properties Sectlon propertles Unit Gross area of the section. (Ag) [in2] Moment of Inertia (principal axes) (1� [in4] Bending constant for moments (principal axis) (J') (in) Radius of gyration (principal axes) (r� (in] Saint-VenaM torsion constant. (J) [in4] Section warping constant. (G1nr) [in6j Distance from centroid to shear center (principal axis) (xo,yo) [in] Top elastic section modulus of the section (principal a�ds) (S'sup) [in3] Bottom elastic section modulus of the section (principal axis) (S'in� [in3J Polar radius of gyration. (ro) [in] Mate�lal : A570 Gr50 cold form MaJor auls 0.147 0.063 0.000 0.653 2.10E-04 0.000 -0.876 0.057 0.057 1.101 Descrlptlon Unit Value Yield stress (Fy): [KipM2] 50.00 Tensile strength (Fu): [Kipfin2] 65.30 Elasticity Modulus (E): [Kipfin2] 29000.00 Shear modulus for steel (G): [Kipfin2] 11507.94 DESIGN CRITERIA Description Effective length factor (I� Effedive length factor for torsion Unbraced compression length (Lx, Ly) Length for torsion and lateral-torsional buckling Lateral bracing Mlnor axis 0.003 2.223 0.134 0.000 0.011 0.010 Unit Ma)or axis Mlnor axis — 1.78 1.83 — 1.00 [ft] 4.50 4.50 [ftj 7.50 — Yes Yes Additional hypotheses Bearing length Positive flange fastened Negative flange fastened Continuous lateral torsional restraint SERVICE CONDITIONS Verlflcation Unit Maximum geometric slendemess (Ur) — Geometric slendemess (KUr) — - Slendemess greater than recommended (KUr 200) Deflection in compression and/or bending [in] DESIGN CHECKS DESIGN FOR FLEXURE "� Bendina about malor axis. M33 Ratio . 0.28 Capacity . 0.09 [IGp*ft] Demand . -0.03 [IGp*ft] [in] 0.00 No No No Value Ctrl EQ 179.80 329.77 1.34 c08 at 100.00% Reference (Com. C4F) Reference : (Sec. C3) Ctri Eq. : c17 at 2.34% Intermedlate results Unit Value Reference Nominal flexural strenath (Mnxl [Kip'ft] 0.15 (Sec. C3) Bendina strenath factor (��, — 1,67 (Sec. C3.1.1) Bendina about minor axis. M22 Ratio . 0.27 Capacity . 0.05 [Kip*ft] Reference : (Sec. C3) Demand . -0.01 [Kip•ft] Ctri Eq. : c05 at 60.94% Intermediate results Unit Value Reference Nominal flexural strenath (Mnv) [Kip'ft] 0.08 (Sec. C3) Bendina strenath factor ($1 — 1.67 QSec. C3.1.1) DESIGN FOR SHEAR � Shear oarallel to minor axis. V2 Ratio . 0.03 Capacity . 2.33 [Kip] Reference : (Sec. C3.2) Demand . -0.07 [Kip] Ctrl Eq. : c13 at 0.00% Intermediate results Unit Value Reference Nominal shear strenath Nn) [Kip] 3.73 (Sec. C3.2) Shear strenath factor (�v_� — 1.60 (Sec. C3.2.1) Shear oarallel to malor auls. V3 Ratio Capacity Demand Intertnediate results Nominal shear strenqth Nn) Shear strenath factor ($1 0.02 2.33 [Kip] 0.05 [Kip] Reference Ctrl Eq. Unit [Kip] : (Sec. C3.2) : C17 at 0.00°r6 Value Reference 3.73 (Sec. C3.2) 1.60 (Sec. C3.2.1) DESIGN FOR TENSION � Tension Ratio . 0.00 Capacity . 5.26 [Kip] Reference : (Eq. C2-1) Demand . 0.00 [Kipj Ctrl Eq. : c01 at 0.00% Intermedlate results Unit Value Reference Nominal tension strength (Tnl [Kip] 8.79 (Sec. C2) Tension strenath factor (�t� — 1.67 (Sec. C2) DESIGN FOR COMPRESSION "� Comoression Ratio . 0.70 Capacity . -0.23 [Kip] Demand . -0.16 [Kip] Intertnediate results Nominal comoression strenath (Pnl Comoression strenath factor (�,, Reference Ctr1 Eq. Unit IK�PI : (Sec. C4) : c05 at 0.00% Value Reference -0.41 (Eq. C4.1) 1.80 (Sec. C41) DESIGN FOR TORSION "� Torsion Ratio . 0.19 Capacity . 0.01 [Kip*ft] Reference :(AISC, Sec. H) Demand . 0.00 [Kip*ft] Ctrl Eq. : c13 at 61.72°k Intermedlate results Unit Value Reference Nominal torsion strenath [Kip*ft] 0.01 Torsion strenath factor ($1 — 1.67 DESIGN FOR CRIPPUNG (N/A) INTERACTION � Combined bendlna and web crloollna ratlo � � Ratio . 0.00 Ctrl Eq. : C01 at 0.00% *The equation has been modified for a maximum ratlo equal to 1.0 Combined bendina and shear ratlo Ix-xl Ratio . 0.28 Ctrl Eq. : c17 at 2.34% Reference : C3.3.1-1 Combined bendina and shear ratlo (v-vl Ratio . 0.17 Ctri Eq. : c05 at 60.94% Reference : C3.3.1-1 Combined flexure and tension ratlo Ratio . 0.38 Ctrl Eq. : c12 at 43.75% Reference : C5.1.1-2 Combined flexure and comoresslon ratlo Ratio . 0.90 Ctr1 Eq. : c09 at 1.56% Reference : C5.2.1-1 CRITICAL STRENGTH RAT10 � ............................................................................................................................................................................. Ratio . 0.90 Ct�l Eq. . c09 at 1.56% Reference : C5.2.1-1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Member . 48 (spreader) Design status . OK PROPERTIES Secvon Information Section name: aisiC 1.25x4.5x.068 (US) Dimensions �-- .---� +�~ : �I. �.��*: �' ! Lb I I I • ! � -. . � a:.�. a 1.250 [in] Flange width b = 4.500 [in] Depth r = 0.136 [in] Inside bend radius t = 0.068 (in] Thickness Properties Sectlon properties Gross area of the section. (Ag) Moment of Inertia (principal axes) (I') Bending constant for moments (principal axis) (J') Radius of gyration (principal axes) (r� Saint-Venant torsion constant. (J) Section warping constant. (Cw) Distance from centroid to shear center (principal axis) (xo,yo) Top elastic section modulus of the section (principal a�ds) (S'sup) Bottom elastic section modulus of the section (principal axis) (S'infl Polar radius of gyration. (ro) Material : A570 Gr50 cold form Description Yield stress (Fy): Tensile strength (Fu): Elasticity Modulus (E): Shear modulus for steel (G): DESIGN CRITERIA Descrlptlon Effective length factor (Iq Effective length factor for torsion Unbraced compression length (Lx, Ly) Length for torsion and lateral-torsional buckling Lateral bracing Additional hypotheses Bearing length Positive flange fastened Negative flange fastened Continuous lateral torsional restraint SERVICE CONDITIONS Verlflcation Maximum geometric slendemess (Ur) Geometric slendemess (KUr) Deflection in compression and/or bending DESIGN CHECKS DESIGN FOR FLEXURE � Bendina about malor axis. M33 Ratio . 0.02 Capacity . 1.25 [Kip`ft] Demand . 0.02 [Kip*ft] Intermediate results Nominal flexural strenath (Mnxl Bendina strenath factor ($1 Unit [inj J � Unit Major axls Minor axis [in2] 0.456 [in4j 1.250 0.059 [in] 0.000 2.723 [in] 1.656 0.361 [in4] 7.19E-04 [in6] 0.214 [in] -0.626 0.000 (in3] 0.556 0.060 [in3] 0.556 0.232 [in] 1.807 Unit [Kip/in2] [Kip/in2] [Kip/in2] [Kip/in2] Value 50.00 65.30 29000.00 11507.94 Unit MaJor axis Mlnor axis — 1.00 1.00 — 1.00 [ft] 2.00 2.00 [ft] 2.00 — No No [inj 0.00 No No No Value Ctrl EQ 66.57 66.57 0.00 c08 at 75.00% Reference (Com. C4F) Reference : (Sec. C3) Ctri Eq. : c16 at 100.00% Unit Value Reference [Kip'ft] 2.09 (Sec. C3) — 1.67 (Sec. C3.1.1) Bendins� about minor axis. M22 Ratio . 0.06 Capacity . 0.11 [Kip"ft] Demand . -0.01 [Kip'ft] Intermedlate results Nominal flexural strength (Mn� Bendina strenath factor (�� Reference Ctr1 Eq. Unit [Kip'ft] : (Sec. C3) : C12 at 100.00% Value Reference 0.19 (Sec. C3) 1.67 (Sec. C3.1.1) DESIGN FOR SHEAR � Shear oarallel to minor a�cis. V2 Ratio . 0.00 Capacity . 4.83 [Kip] Reference : (Sec. C3.2) Demand . 0.02 [Kip] Ctrl Eq. : c08 at 0.00% Intermedlate results Unit Value Reference Nominal shear strenath Nn) [Kip] 7.72 (Sec. C3.2) Shear strenath factor (�y� — 1.60 (Sec. C3.2.1) Shear oarallel to malor auls. V3 Ratio . 0.00 Capacity . 2.67 [Kip] Reference : (Sec. C3.2) Demand . 0.00 [Kipj Ctrl Eq. : c12 at 0.00% Intertnediate resuks Unit Value Reference Nominal shear strenath Nn) [Kip] 4.27 (Sec. C3.2) Shear strenath factor (�� — 1.60 (Sec. C3.2.1) DESIGN FOR TENSION � Tenslon Ratio . 0.00 Capacity . 13.68 [Kip] Demand . 0.04 [Kip] Intermedlate results Nominal tension strenath (Tnl Tension strenath factor (�� DESIGN FOR COMPRESSION � Comoresslon Ratio . 0.00 Capacity . -7.15 [Kip] Demand . 0.00 [Kip] Reference Ctri Eq. Unit [Kip] Reference Ctrl Eq. : (Eq. C2-1) : c13 at 0.00% Value Reference 22.85 (Sec. C2) 1.67 (Sec. C2) (Sea C4) c09 at 0.00% Intermedlate results Nominal com�ression strenath (Pn) Compression strenath factor (�c� Unit [Kip] Value Reference -12.87 (Eq. C4.1) 1.80 (Sec. C41) DESIGN FOR TORSION � Torsion Ratio . 0.04 Capacity . 0.02 [Kip'ft] Reference :(AISC, Sec. H) Demand . 0.00 [Kip*ft] Ctrl Eq. : c05 at 0.00% Intermediate results Unit Value Reference Nominal torsion strenath [Kip`ft] 0.03 Torsion strenath factor (�� — 1.67 DESIGN FOR CRIPPLING � Web crioolina stren�tth Ratio . 0.00 Capacity . 0.73 [IGp] Reference : (Sec. C3.4) Demand . 0.00 [Kip] Ctrl Eq. : c01 at 0.00% Intermedlate results Unit Value Reference Nominal crioolina strenath (Pnl [Kip] 1.35 (Eq. C3.4.1-1) Crioolina strenath factor (�� — 1.85 (Tables C3.4.1) Crioolina strenath factor (�w�, — 1.85 (Tables C3.4.1) INTERACTION '� Combined bendins� and web criuolins� ratio Ratio . 0.01 "The equatlon has been modlfled for a maxlmum ratlo equal to 1.0 Combined bendina and shear ratlo (x-x1 Ratio . 0.02 Combined bendina and shear ratlo Iv-vl Ratio . 0.06 Combined flexure and tenslon ratlo Ratio . 0.07 Ctr1 Eq. Reference Ctr1 Eq. Reference Ctr1 Eq. Reference Ctrf Eq. c16 at 100.00°� C3.5.1-1 c16 at 100.00°k C3.3.1-1 c12 at 100.00°k C3.3.1-1 c12 at 100.00°k e � Reference : C5.1.1-2 Combined flexure and comoression ratio Ratio . 0.07 Ctri Eq. : c12 at 100.00°� Reference : C5.2.1-2 CRITICAL STRENGTH RATIO "� ............................................................................................................................................................................. Ratio . 0.07 Ctrl Eq. . c12 at 100.00% Reference : C5.2.1-2 ............................................................................................................................................................................. DESIGN CALCULATIONS FOR - LOZIER SHELVING s � � �-�: REViEWED FOR 'CODE COMPLIANCE ::��"'` APPROl�ED ��t AUG 0 2 2016 1 � �, ' ��: � Gity �fiTukwila BURLINGTON COAT FACTORY No. 1005 PARKWAY SUPER CENTER 17480 SOUTHCENTER PARKWAY TUKWILA, WA 98188 � NOTE: THESE CALCS ARE TO SUPPLEMENT THE SHELVING INSTALLATION MANUALS THAT ARE ISSUED FOR EACH PROJECT. ALL SHELVING COMPONENTS SHALL BE INSTALLED ACCORDING TO THE MANUFACTURER'S RECOMMENDATIONS. NOTIFY ENGINEER WITH ANY DISCREPANCIES. CITY OF TUKWILA JUL 20 2016 PERMtT CENTER � ��o wq �y��\����1� �'��' yci: . e a: « ''- - � : : N Z . �► � � • : � pp ': q 14723 p ' �� �1►�E`n '����� � 'T.1�2.�t c.p JOB: 16279 DATE: 07/07/16 JOE P. HILL, P.E. BY: CD CHD: �pH CONSULTING STRUCTURAL ENGINEERING 1801 N. HAMPTON RD., SUITE 440 DESOTO, TX 75115-2399 972-283-5111 E-Mail:Joe@jphpe.com Page 1 of 84 0 TABLE OF C.ONTENTS DESIGN INFORMATION - ---------------------------------------------------------------------------------------------------- FRAME B-WM �------------------------------------------------------------------------------------------------------ FRAME B-R12 ------------------------------------------------------------------------------------------------------ FRAME E1 �- ---------------------------------------------------------------------------------------------------- ANCHOR PLATE DESIGN - ---------------------------------------------------------------------------------------------------- SLAB PUNCH SHEAR - ---------------------------------------------------------------------------------------------------- APPENDIX A �- ---------------------------------------------------------------------------------------------------- APPENDIX B �- ---------------------------------------------------------------------------------------------------- APPENDIX C(ANCHOR BOLT DESIGN & ICC _ESR-3027) --------------------- ----------------------------------------------------------- 3-8 9-27 28-46 47-82 83 84 A 1 - A46 B1 - B8 C1 - C22 JOB: 16279 DATE: 07/07/16 JOE P. HILL, P.E. BY: CD CHD: �pH CONSULTING STRUCTURAL ENGINEERING 1801 N. HAMPTON RD., SUITE 440 DESOTO, TX 75115-2399 972-283-5111 E-Mail:Joe@jphpe.com Page 2 of 84 O _ �� ��� � BUILDING CODE: �1--��ERNATIONAL BUILDING CODE ASCE 7-10 & RMI (AS IT APPLIES) LOCATION : TUKWILA, WA ALLOWABLE SHELVING LOADS FRAME B-WM: 22" B x 48" W x 90" H WALL MOUNTED SHELVING (8 SHELVES) SIM. 22" B x 36" W x 90" H WALL MOUNTED SHELVING (8 SHELVES) SHELVING LOADS DL = 3 PSF PL = 8 PSF FRAME B-R12: 22" B x 48" W x 120" H WALL MOUNTED SHELVING (13 SHELVES) SHELVING LOADS DL = 3 PSF PL = 5 PSF FRAME E1: 36" B x 96" W x 144" H WIDESPAN SHELVING (3 SHELVES) SHELVING LOADS DL = 5 PSF/SHELF PL = 180 LBS/SHELF SHELVING FRAMING TYPES FRAME B: FRAME IS CANTILEVERED COLUMN SYSTEM IN TRANSVERSE DIRECTION AND MOMENT FRAME SYSTEM IN LONGITUDINAL DIRECTION. FRAMES E1: FRAME IS MOMENT FRAME SYSTEM IN TRANSVERSE DIRECTION AND MOMENT FRAME SYSTEM IN LONGITUDINAL DIRECTION. ,loB: � g279 DATE: 07/07/16 JOE P. HILL, P.E. BY: Cp CHD: �pH CONSULTING STRUCTURAL ENGINEERING 1801 N. HAMPTON RD., SUITE 440 DESOTO, TX 75115-2399 972-283-5111 E-Mail:Joe@jphpe.com Page 3 of 84 ♦ // '�\ � � �.` ,� ..� BUILDING CODE: 2015 INTERNATIONAL BUILDING CODE W/ 2015 WASHINGTON STATE CODE AMENDMENTS LOGATION : TUKWILA, WA ALLOWABLE SHELVING LOADS FRAME B-WM: 22" B x 48" W x 90" H WALL MOUNTED SHELVING (8 SHELVES) SIM. 22" B x 36" W x 90" H WALL MOUNTED SHELVING (8 SHELVES) SHELVING LOADS DL = 3 PSF P� = 8 PSF FRAME B-R12: 22" B x 48" W x 120" H WALL MOUNTED SHELVING (13 SHELVES) SHELVING LOADS D� = 3 PSF PL = 5 PSF FRAME E1: 36" B x 96" W x 144" H WIDESPAN SHELVING (3 SHELVES) SHELVING LOADS DL = 5 PSF/SHELF PL = 180 LBS/SHELF SHELVING FRAMING TYPES FRAME B: FRAME IS CANTILEVERED CO�UMN SYSTEM IN TRRNSVERSE DIRECTION AND MOMENT FRAME SYSTEM IN LONGITUDINAL DiRECTION. FRAMES E1: _ �.,.o,,,r� ���' p� H�1����1 FRAME IS MOMENT FRAME SYSTEM IN TRANSVERSE DIRECTION �, •f'�qs�.,, 1� AND MOMENT FRAME SYSTEM IN LONGITUDINAL DtRECTION. ;��� �yc:, -� . f � �,�. :, o ; .� :y �.fki�- �� �, � p� '. 4723 ` � i--�L��ec��'•�r'. ��0._'t`��� .IOB: �g279 DATE: 07/29/16 JOE P. HILL, P.E. BY: Cp CHD: JPH CONSULTING STRUCTURAL ENGINEERING 1801 N. HAMPTON RD., SUITE 440 DESOTO, TX 75115-2399 972-283-5111 E-Mail:Joe@jphpe.com Page 3 of 84 � �, f } r � July 29, 2016 City of Tukwila Department of Community Development 630Q Southcenter Blvd, Suite #100 Tukwila, WA 206.431.3670 Re: Correction Letter # 1 Development Permit Application #: D16-0198 Burlington Coat Factory — 17480 Southcenter Pkwy Rllen Johannessen In regards to your structural review comments from .7uly 29, 2016; we offer the following response: BUILDING REVIEW NOTES 1. Changed International Building Code form 2012 to 2015 on page 3 of the calculations and on sheet Sl of the plans. This will not affect the current design or calculations. Should you have any questions or concerns, please contact us directly at 972-283- 5111. Sincerely, )d�. Hill, P. E. President JPH:CD ,�`�pE P. H��lt�h � .; oF �wAS;S;•, �1 �' �� ��,• • � a �: � :N �: .� : ' � . . O ': 9 14723 p rW (t�.,'•:��'L`� s : ��►4 JOE P. HILL, P.E. CONSULTING STRUCTURAL ENGINEERING 1801 N. Hampton Rd., Suite 440 DeSoto, TX 75115-2399 972-283-5111 ����� It/E% CITY O� TU6CWIL� JUL 2 9 2016 PERMIT CENTER C4�R�C7�►N LTR#�� � ��� � Q��� .4 . e ���� Design Maps Summary Report User-Specified Input . Report Title Tukwila, WA Thu July 7, 2016 21:29:38 UTC Building Code Reference Document 2012/2015 International Building Code (which utilizes USGS hazard data available in 2008) Site Coordinates 47.44585°N, 122.26011°W Site Soil Classification Site Class D-"Stiff Soil" '_ : �y �' Vash4r�, �, � 1 .� � ,- l '�c Risk Category I/II/III - ----- �r* *sxsxrw�- - --- � -- - ----� ;' ' o nlir� � � � � -=--� ; � �� : � �._^_� ,� �` - ` �,,�.',\ � REN7'ON � - " : ..� S�Ud�i ' :� � � � ;� � II�UNI �M " �'� � I _ 1; �:__ )RP�RTl �, y � `� � �.. , � ., • -�• � , ,{�� a-.� Buri�r� �SEAiTi� r�rn�t,� �r�. �,aPo�� � . ..- � L�es;Moin+e�s,� R, . r d � ;' ^ r�' : '`r USGS-Provided Output SS = 1.442 g Sl = 0.537 g �L ° l�-�r�t�n � x ��� . `.' '� .,_ , �.�. ; ..i'�-i- `-' ";. � ,_,. � . , s� � ' j � '�, ,�;,. I ' / ' ,`.. �� t,f � . , �`: Maple V�iley . • t� %� � C , � ,j {�._. ( �r �'�l-•' `. 'J' '� � f �I� Q" � � / � •.. �� _ �,�Co�ni��ton � ,�_ _ , �, �' � ��u��► _ �� SMS = 1.442 9 Sos = 0.961 g SMl = 0.806 9 Sol = 0.537 g For information on how the SS and S1 values above have been calculated from probabilistic (risk-targeted) and deterministic ground motions in the direction of maximum horizontal response, please return to the application and select the "2009 NEHRP" building code reference document. MCE� Response 5pectrum 1.65 1.50 1.35 1.20 1.05 � 0.90 y 0.75 0.6D , D.45 0.3D 0.15 O.OD U.DD D.20 O.�D 0.60 0.90 1.00 1.30 1.iD 1.60 1.80 2.OD Period, T (secj Design Response Spectrum i.ia 1.00 0.9D O.BD 0.70 O� 0.6D y O.SD O.�D 0.3D 0.20 0.3 0 D.00 D.00 0.20 O.10 0.6D O.BD 1.00 1.20 1.l0 1.6D 1.80 2.00 Period, T (sec� Although this information is a product of the U.S. Geological Survey, we provide no warranty, expressed or implied, as to the accuracy of the data contained therein. This tool is not a substitute for technical subject-matter knowtedge. Page 4 of 84 A � • a b .n �U�j� Design Maps Detailed Report 2012/2015 International Building Code (47.44585°N, 122.26011°W) Site Class D-"Stiff Soil", Risk Category I/II/III Section 1613.3.1 — Mapped acceleration parameters Note: Ground motion values provided below are for the direction of maximum horizontal spectral response acceleration. They have been converted from corresponding geometric mean ground motions computed by the USGS by applying factors of 1.1 (to obtain SS) and 1.3 (to obtain Sl). Maps in the 2012/2015 International Building Code are provided for Site Class B. Adjustments for other Site Classes are made, as needed, in Section 1613.3.3. From Fiaure 1613.3.11i1 �l� From Figure 1613.3.1�2) �2� Section 1613.3.2 — Site class definitions SS = 1.442 g 51=0.537g The authority having jurisdiction (not the USGS), site-specific geotechnical data, and/or the default has classified the site as Site Class D, based on the site soil properties in accordance with Section 1613. 2010 ASCE-7 Standard - Table 20.3-1 SITE CLASS DEFINITIONS Site Class A. Hard Rock B. Rock C. Very dense soil and soft rock D. Stiff Soil E. Soft clay soil F. Soils requiring site response analysis in accordance with Section 21.1 vs N or N�,, s„ >5,000 ft/s N/A N/A 2,500 to 5,000 ft/s N/A N/A 1,200 to 2,500 ft/s >50 >2,000 psf 600 to 1,200 ft/s 15 to 50 1,000 to 2,000 psf <600 ft/s <15 <1,000 psf Any profile with more than 10 ft of soil having the characteristics: • Plasticity index PI > 20, • Moisture content w>_ 40%, and • Undrained shear strength s� < 500 psf See Section 20.3.1 For SI: lft/s = 0.3048 m/s llb/ft2 = 0.0479 kN/mz Page 5 of 84 Section 1613.3.3 - Site coefficients and adjusted maximum considered earthquake spectral response acceleration parameters TABLE 1613.3.3(1) VALUES OF SITE COEFFICIENT Fa Site Class Mapped Spectral Response Acceleration at Short Period SS 5 0.25 SS = 0.50 SS = 0.75 SS = 1.00 SS >_ 1.25 A 0.8 0.8 0.8 0.8 0.8 B 1.0 1.0 1.0 1.0 1.0 C 1.2 1.2 1.1 1.0 1.0 D 1.6 1.4 1.2 1.1 1.0 E 2.5 1.7 1.2 0.9 0.9 F See Section 11.4.7 of ASCE 7 Note: Use straight-line interpolation for intermediate values of SS For Site Class = D and SS = 1.442 g, Fe = 1.000 TABLE 1613.3.3(2) VALUES OF SITE COEFFICIENT F„ Site Class Mapped Spectral Response Acceleration at 1-s Period S1 <_ 0.10 S1 = 0.20 S, = 0.30 S1 = 0.40 S, >_ 0.50 A 0.8 0.8 0.8 0.8 0.8 B 1.0 1.0 1.0 1.0 1.0 C 1.7 1.6 1.5 1.4 1.3 D 2.4 2.0 1.8 1.6 1.5 E 3.5 3.2 2.8 2.4 2.4 F See Section 11.4.7 of ASCE 7 Note: Use straight-line interpolation for intermediate values of Sl For Site Class = D and Sl = 0.537 g, F„ = 1.500 Page 6 of 84 Equation (16-37): Equation (16-38): SMS = FaSs = 1.000 X 1.442 = 1.442 g SM1 = F„S1 = 1.500 x 0.537 = 0.806 g Section 1613.3.4 — Design spectral response acceleration parameters Equation (16-39): Equation (16-40): SDS - 2� SMS - Z� X 1.442 = 0.961 g SDl -� SM1 - z� x 0.806 = 0.537 g Page 7 of 84 Section 1613.3.5 — Determination of seismic design category SE: TABLE 1613.3.5(1) :SMIC DESIGN CATEGORY BASED ON SHORT-PERIOD (0.2 second) RESPONSE ACCELERATION RISK CATEGORY VALUE OF Sos I or II III IV Sps < 0.167g A A A 0.167g 5 Sps < 0.33g B B C 0.33g <_ Sps < 0.50g C C D 0.50g <_ Sps D D D For Risk Category = I and Sps = 0.961 g, Seismic Design Category = D TABLE 1613.3.5(2) SEISMIC DESIGN CATEGORY BASED ON 1-SECOND PERIOD RESPONSE ACCELERATION RISK CATEGORY VALUE OF Sol I or II III IV Spl < 0.067g A A A 0.067g 5 Spl < 0.133g B B C 0.133g <_ Spl < 0.20g C C D 0.20g <_ Spl D D D For Risk Category = I and Sp, = 0.537 g, Seismic Design Category = D Note: When S1 is greater than or equal to 0.75g, the Seismic Design Category is E for buildings in Risk Categories I, II, and III, and F for those in Risk Category IV, irrespective of the above. Seismic Design Category =_ "the more severe design category in accordance with Table 1613.3.5(1) or 1613.3.5(2)" = D Note: See Section 1613.3.5.1 for alternative approaches to calculating Seismic Design Category. References 1. Figure 1613.3.1(1): http://earthquake.usgs.gov/hazards/designmaps/downloads/pdfs/IBC-2012-Fig1613p3p1(1).pdf 2. Figure 1613.3.1(2): http://earthquake.usgs.gov/hazards/designmaps/downloads/pdfs/IBC-2012-Fig1613p3p1(2).pdf Page 8 of 84 u FRAME B-WM LOZIER WALL MOUNT SHELVING 22•B x 48" L x 90• H WALL MOUNT ,IOB: � 6279 DATE: 07/07/16 JOE P. HILL, P.E. BY: Cp CHD: �pH CONSULTING STRUCTURAL ENGINEERING 1801 N. HAMPTON RD., SUITE 440 DESOTO, TX 75115-2399 972-283-5111 E-Mail:Joe@jphpe.com Page 9 of 84 0 SEISMIC DESIGN FRAME B-WM (22". B x 48"L x 90"H WALL) ASCE 7& RMI (AS IT APPLIES) EQUIVALENT LATERAL FORCE PROCEDURE FOR SHELVING WALL Bt' OTNERS £�� e . Width = 22 IN L��� � Length = 48 IN E 6 Max. Shelving Height = 90 IN Levels = 8 L L 9 LEVEL 4 H SS = 1.442 � S� = 0.537 Site Class = LEvEL 9 E L 2 Fa = 1.000 F� = 1.500 `E" " Sos = 2/3(Fa)SS = 0.961 Sp� = 2/3(F„)S� _ w Seismic Use Group = I SEISMIC DESIGN CATEGORY = CS = Soi TR CS = 1.48 Cs, naax = S�s R Cs, MIN - �.�44SDS SEISMIC BASE SHEAR, V= CS Ip WS T=0.02*h�3/4)_ R = 4.00 Ip = 1.50 CS, M,vc = Cs, MIN - 0.537 0.09 (RMI Sec. 2.6.3) (RMI Sec. 2.6.2) 0.24 « CONTROLS 0.04 LOADS DL = 3 PSF PL = 8 PSF (FIRST LEVEL) PL = 8 PSF TOTAL FRAME WEIGHT Ws = DL + 67%PL + 0.25LL (Per Storage Rack Section) DL = 3 PSF x 1.83 FT x 4 FT x 8 SHELVES = 176.00 LBS PL = 8 PSF x 1.83 FT x 4 FT x 7 SHELVES x 0.67 = 275.15 LBS PL = 8 PSF x 1.83 FT x 4 FT x 1 SHELVES x 0.67 = 39.31 LBS (FIRST LEVEL) WS = 490.45 LBS 0.525 x VBASE = 93 LBS IF TOP SHELF 100% LOADED ONLY, 0.525 x VTOP = 44 LBS ,loB: � 6279 DATE: 07/07/16 JOE P. HILL, P.E. BY: Cp CHD: JPH CONSULTING STRUCTURAL ENGINEERING 1801 N. HAMPTON RD., SUITE 440 DESOTO, TX 75115-2399 972-283-5111 E-Mail:Joe@jphpe.com Page 10 of 84 0 SEI$MIC DESIGN - FRAME B-WM (CONTINUED) TOTAL = 490.45 Ibs per rack DISTRIBUTED LATERAL FORCES WXhXk Fx=(C„x) V C„x = E W; h�k U Bnse = 93 LBS PsTa,ric = 490.45 Ibs per post k= 1.0 since Ta <_ 0.50 E (FX'` h) = 453.14 LBS-FT LW = 22 IN L� = 48 IN CONNECTION DISTANCE H= 84 IN TRANSVERSE: W = 490.45 LBS M cRa,virv = W(LW/2)/12 = 449.58 LBS-FT M sEisnnic = E�FX X h) = 453.14 LBS-FT TENSION AT WALL CONNECTION = SHEAR AT WALL CONNECTION = 129 LBS 93 LBS ,10g: 16279 DATE: 07/07/16 JOE P. HILL, P.E. BY: Cp CHD: �pH CONSULTING STRUCTURAL ENGINEERING 1801 N. HAMPTON RD., SUITE 440 DESOTO, TX 75115-2399 972-283-5111 E-Mail:Joe@jphpe.com Page 11 of 84 O 22"B X 90"N IUALL MOUINt 4'-O�� w N � w } � - Z N d � � � W LONCx17UD INAL c i _ Q PLAN YIEW OF tYPIG,4L LAl'OUT FOR FRAME "B—WM" _� O O "� O � �. � r O � O � � O �t cA 61.31" 61.31� �01.31�' 61.31M 61.31�' 61.31" 61.31� 61.31" L �''—O" L �— F x C8) —� Fx(7) —� Fx(6� � FxlS) � FxC4) —� Fxl3) —� �x(2) —� Fxll) UJALL BY OTHEI TYP. FRONt PROFILE OF �RAME "B—WM" TYP. END PROPILE OF FR4ME "B—WM" .log: � 6279 DATE: 07/07/16 JOE P. HILL, P.E. BY: Cp CH�: �pH CONSULTING STRUCTURAL ENGINEERING 1801 N. HAMPTON RD., SUITE 440 DESOTO, TX 75115-2399 972-283-5111 E-Mail:Joe@jphpe.com Page 12 of 84 0 OVERTURNING MOMENTS TOP SHELF LOADED - FRAME B-WM (CONTINUED) DISTRIBUTED LATERAL FORCES WxhXk FX =(C�x) V k= 1.0 since Ta <_ 0.50 C�x = � w, il;k V TOP - � LBS LW = 22 IN L� = 48 IN CONNECTION DISTANCE H= 84 IN TRANSVERSE: W= 234.67 LBS LOAD TOP SHELF ONLY M cRavirY = W�Lw/2)/12 = 215.11 LBS-FT M sEisMic =��FX x h) = 248.90 LBS-FT TENSION AT WALL CONNECTION = 67 LBS SHEAR AT WALL CONNECTION = 45 LBS .log: � 6279 DATE: 07/07/16 JOE P. HILL, P.E. BY: Cp CHD: �pH CONSULTING STRUCTURAL ENGINEERING 1801 N. HAMPTON RD., SUITE 440 DESOTO, TX 75115-2399 972-283-5111 E-Mail:Joe@jphpe.com Page 13 of 84 0 COMPONENT DESIGN FOR FRAME B-WM NOTE:SECTION PROPERTIES LISTED ON COMPONENT DESIGN SHEETS, REFER TO APPENDIX B IN REPORT, INDICATING SHAPE, SIZE & RISA SECTION PROPERTIES FOR EACH COMPONENT. 22 IN . SHELF: LENGTH OF SHELF (L�) = 4.00 FT Fy = 45 KSI MIN. W DL+LL - 20.�% PLF MAX. M SHELF - W DL+LL x L�z I H X � 2= 4H4.00 LBS-IN MAX. V SHELF - l•• DL+LL X L� � 2� = 40.33 LBS FROM RISA SECTION: REQD Sx = M sHE�F / 0.6 Fy = 0.018 IN3 Ix = 0.119 IN4 Sx = 0.099 IN3 OK REQD AREA = V sHE�F / 0.4 Fy = 0.002 INZ SHELF BRACKET: TL STYLE MAX SPAN (LS) = 22 IN AREA = 0.959 INZ OK THEREFORE SHELF IS OK Fy = 70 KSI MIN. LENGTH OF SHELF (L�)= 4.00 FT WDL+LL+O.SBPL -�DL+LL+O.HHPL� X I{ I Z= ZO.OH PLF PVERT IMPACT - WDL+LL+0.88PL X ZrJ% = 5.02 LBS M�MAX� _��WDL+LL+0.88PL X LS2 � 24� +�PVERT IMPACT X LS �I - 5�5.39 LBS-IN V�MAX% =��WDL+LL+0.86PL X LS% + PVERT IMPACT J- 4�.H3 LBS ASSUME ONLY TOP CLIP IN TENSION AREA = 0.951" x 0.12" = 0.11 TENSION CAPACITY = AREA x 0.6Fy = 4793 LBS MOMENT CAPACITY = TENSION CAP. x 1.82 IN = 8723 LBS-IN MOMENT CAPACITY > M(MAX) CHECK SHEAR OF BRACKET un��ow = AREA x 0.4Fy = 3195.36 LBS OK THEREFORE SHELF BRACKET IS OK INZ OK .log: � 6279 DATE: 07/07/16 JOE P. HILL, P.E. BY: Cp CHD: JPH CONSULTING STRUCTURAL ENGINEERING 1801 N. HAMPTON RD., SUITE 440 DESOTO, TX 75115-2399 972-283-5111 E-Mail:Joe@jphpe.com Page 14 of 84 COMPONENT DESIGN - TRANSVERSE DIRECTION (FRAME B-WM) UPRITE . �_ ,� Y� a� ( SECTION PROPERTIES MAX HT = 90 IN �` i Fy = 55000 PSI � AREA = 0.757 INZ ly = 0.237 IN° � ; Ix = 0.817 IN4 Sy = 0.250 IN3 '� j Sx = 0.630 I N3 ry= 0.560 I N � rx = 1.039 I N 52,c= 1.80 -�;�—�. __._._._._i._._._._._._ ._._.__.__ � C„� 1.0 S2b= 1.67 F� � Unbrace Lx-x = 90 IN Kx = 1.7 ; Unbrace Ly-y = 14 IN Ky = 1.0 Rj � Span (LS) = 22 IN I - ; — Psra,ric = 490.45 LBS MAX MsrnTic = PsTnTic x(LS/12) / 2= 449.58 LBS-FT kLx _ 1.7 90 = 147.26 <-- CONTROLS rx 1.0391 N � _ �� = 25.00 ry 0.561 N Fa = � * E = 13199 PSI (KI/r)2 �c = (Fy / Fa)��2 = Fn =j �'c < 1.5 (0.658'���Fy _ l �,c > 1.5 (0.877/ �,c2)Fy Pn = AREA * Fn = PEX = (7t2Elx) � �Kx�x)2 = ax = 1 — (52�P/Pex) _ MAX MOMENT IN COLUMN 2.04 >1.5 11576 PSI 8762.77 LBS 9989.34 LBS 0.91 COLUMN SECTION Mx = MsTATic = 449.58 LBS-FT Mx = MseisMic = EiFX x h) = 453.14 LBS-FT <— CONTROLS M„ = Sx " Fy = 2887.50 LBS-FT COMBINED STRESS = fa/Fa + fp/Fb = (S2CP/Pn) + ��pCmxM�/Mnoc�) = 0.39 < 1.0 THEREFORE UPRITE IS OK .loB: 16279 DATE: 07/07/16 JOE P. HILL, P.E. BY: Cp CHo: �pH CONSULTING STRUCTURAL ENGINEERING 1801 N. HAMPTON RD., SUITE 440 DESOTO, TX 75115-2399 972-283-5111 E-Mail:Joe@jphpe.com Page 15 of 84 COMPONENT DESIGN - LONGITUDINAL DIRECTION (FRAME B-WM) RELATIVE SHELF STIFFNESS (22". SHELF): E= 29000 KSI S2 = 1.67 � SHELF - O• � � 9 IN° �� = 48 IN K sHE�F = 384EI / L�3 = 11.983 RELATIVE UPRITE STIFFNESS: � UPRITE - O.Z37 �N° UNBRACED H= 14 IN K uPRi� = 24EI / H3 = 60.114 FROM RISA MODEL (SEE NEXT 4 PAGES): SHELF DESIGN: MAX. M= 0.062 K-FT (MEMBER M6 CONTROLS) MAX. MIMPACT - PVERTIMPACT � �s = 0.009 K-FT MAX. M = 0.071 K-FT Sx = 0.099 IN' Mallow = Sx`Fy/S2 = 0.222 K-FT Mallow > MAX. M OK T=C=M*12/1.82= 0.47 KIP {V � ALLOWABLE SHEAR TO RESIST MOMENT: TAB DISTANCE = 1.82 IN I T TAB = 0.95 IN � � t= 11 GA AREA OF TAB = 0.11 INZ (SEE COMP.CALCS) FY = 70 KSI Vn��ow = 0.4 AREA FY = 3.18 KIP ����F T = C < Vq��pyy OK UPRITE . DESIGN: MAX UNBRACED HT (L�) = 14 IN Fy = 55000 PSI Ls = 22 IN SECTION PROPERTIES FROM RISA SECTION: AREA= 0.757 INZ Sy= 0.250 IN3 IY= 0.237 IN° MSTATIC - PSTATIC �2 � �s�2 = 2697.49 IN-LBS ry= 0.560 IN � _ (0.81(MAX Hn _ 20.00 Fa = 12 � � * E - 373329 PSI ry 0.56 23(KI/r)Z fa/Fa = (PsTnnc)KAREA*Fa) = 0.002 fb/Fb = (MsTATic) / (Sy'Fy/S2) = 0.328 fa/Fa + fb/Fb = 0.329 < 1.00 FROM RISA MODEL OF FRAME B-WM =__> MsTnnc + Mseisrnic = 49.00 LBS-FT fb/Fb =(MsrnTic+ MseisMic) ��Sy'Fy/S2) = 0.071 fa/Fa + fb/Fb = 0.073 < 1.00 THEREFORE UPRITE IS OK ,loB: � 6279 DATE: 07/07/16 JOE P. HILL, P.E. BY: Cp CHD: �pH CONSULTING STRUCTURAL ENGINEERING 1801 N. HAMPTON RD., SUITE 440 DESOTO, TX 75115-2399 972-283-5111 E-Mail:Joe@jphpe.com Page 16 of 84 WALL MOUNT CONNECTIONS TO CMU WALL OPT. 1 ATTACHING UPRITE TO THE 2x4 BLOCK (THROUGH UPRITE INTO BLOCK) ATTACH UPRITE TO WALL AT EVERY 1 UPRITE FRAME TYPICAL 5/16" x 4" LAG SCREW T Max = 129 x 1= 129 LBS (MAX. LOAD) V Ma,x = 93 x 1= 93 LBS (MAX. LOAD) TWITHDRAWL — 23rJ LBS PER INCH OF THREADS (NDS TABLE 11.2A) MIN. EMBEDMENT = 1.25 IN (NDS SEC. 11.1.3) T n��ow = 293.75 LBS PER LAG SCREW TALLOW > MAX T OK USE TYPICAL 5/16" x 4" LAG SCREW (1-1/4" MIN. EMB. IN TO SOLID MATERIAL) ATTACHING 2x4 BLOCKING TO THE WALL MAX. BASE SHEAR, V= 93 LBS MAX., T= 129 LBS ANCHOR 2X4 BLOCK TO THE MASONARY WALL EACH BLOCK HAS TWO MASONARY ANCHORS. PER MOUNT PL, VM,� = 93 LBS PER MOUNT PL, TM� = 129 LBS VALLOW — 5OO LBS TA��ow = 300 LBS LBS COMBINED FORCES (Nd/Nrec�s/3 +�VdNrec)5�3 = 0.31 < 1.0 OK REQD PER 2X4 BLOCK: (2)1/4" DIA. TITEN MASONARY ANCHORS (EMBED 1 1/2" MIN IN TO SOLID MATERIAL) **USE 114" DIA x 4" TITEN MASONARY SCREW ANHORS ,log: 16279 DATE: 07/07/16 JOE P. HILL, P.E. BY: Cp CHp: �pH CONSULTING STRUCTURAL ENGINEERING 1801 N. HAMPTON RD., SUITE 440 DESOTO, TX 75115-2399 972-283-5111 E-Mail:Joe@jphpe.com Page 17 of 84 0 WALL MOUNT CONNECTIONS TO CMU WALL OPT. 2 ATTACHING UPRITE TO THE 2x4 BLOCK THROUGH WALL MOUNT BRACKET PLATE MAX. BASE SHEAR, V= 93 LBS MAX., T= 129 LBS EACH MOUNT BRACKET HAS TWO (2) WOOD SCREWS PER SCREW, VM� = 47 LBS PER SCREW, TM� = 65 LBS VALLOW — �2O LBS TA��ow = 114 LBS/IN (NDS TABLE 11.M) (NDS TABLE 11.26) Tn��ow = 171 LBS Vq��pyy > MAX V OK TALLOW > MAX T OK REQD PER BRACKET: (2) #10 x 1-1/2"" WOOD SCREWS ATTACHING 2x4 BLOCKING TO THE WALL MAX. BASE SHEAR, V= 93 LBS MAX., T= 129 LBS ANCHOR 2X4 BLOCK TO THE MASONARY WALL EACH BLOCK HAS TWO MASONARY ANCHORS. PER MOUNT PL, VM� = 93 LBS PER MOUNT PL, TM,,,X = 129 LBS Vq��pW = �JOO LBS TALLOW — 3OO LBS LBS COMBINED FORCES �Nd�N���5/3 ,f �VdNrec)5�3 = 0.31 < 1.0 OK REQD PER 2X4 BLOCK: (2)1/4" DIA. TITEN MASONARY ANCHORS (EMBED 1 1/2" MIN IN TO SOLID MATERIAL) **USE 1/4" DIA x 4" TITEN MASONARY SCREW ANHORS ,10B: 16279 DATE: 07/07/16 JOE P. HILL, P.E. BY: Cp CHD: �pH CONSULTING STRUCTURAL ENGINEERING 1801 N. HAMPTON RD., SUITE 440 DESOTO, TX 75115-2399 972-283-5111 E-Mail:Joe@jphpe.com Page 18 of 84 WALL MOUNT CONNECTIONS TO CMU WALL OPT. 3 ATTACHING UPRITE THROUGH WALL MOUNT BRACKET PLATE TO THE WALL MAX. BASE SHEAR, V= 93 LBS MAX., T= 129 LBS EACH POST HAS TWO WALL MOUNT BRACKETS (48" O.C.) PER MOUNT PL, VM,,,X = 93 LBS PER MOUNT PL, TM,� = 129 LBS EACH BRACKET HAS TWO MASONARY ANCHORS. PER SCREW, VM,,,X = 47 LBS PER SCREW, TM,� = 65 LBS VALLOW — 5OO LBS TA��ow = 300 LBS LBS COMBINED FORCES (Nd/N��/5/3 +�VdNreclS/3 — O.�O < 1.0 OK REQD PER WALL MOUNT BRACKET: (2) 1/4" DIA. TITEN MASONARY ANCHORS (EMBED 1 1/2" MIN IN TO SOLID MATERIAL) **USE 1/4" DIA x 2 1l2" TITEN MASONARY SCREW ANHORS ,log: 16279 DATE: 07/07/16 JOE P. HILL, P.E. BY: Cp CHp: �pH CONSULTING STRUCTURAL ENGINEERING 1801 N. HAMPTON RD., SUITE 440 DESOTO, TX 75115-2399 972-283-5111 E-Mail:Joe@jphpe.com Pa e 19 of 84 O WALL MOUNT CONNECTIONS TO WALL STUDS OPT. 1 ATTACHING UPRITE TO THE 2x4 BLOCK (THROUGH UPRITE INTO BLOCK) ATTACH UPRITE TO WALL AT EVERY 1 UPRITE FRAME TYPICAL 5/16" x 4" LAG SCREW T nnnx = 129 x 1= 129 LBS (MAX. LOAD) V nnnx = 93 x 1= 93 LBS (MAX. LOAD) Tv�nTHoaa,v� = 235 LBS PER INCH OF THREADS (NDS TABLE 11.2A) MIN. EMBEDMENT = 1.25 IN (NDS SEC. 11.1.3) T a��ow = 293.75 LBS PER LAG SCREW TALLOW > MAX T OK USE TYPICAL 5/16" x 4" LAG SCREW (1-1/4" MIN. EMB. INTO MATERIAL) ATTACHING 2x4 BLOCKING TO THE WALL MAX. BASE SHEAR, V= 93 LBS MAX., T = 129 LBS USE 1 5/16" LAG SCREWS @ EACH STUD (1-1/4" MIN EMB.) OR 2 #8 SELF-DRILLING DRY WALL SCREWS (�D_ EACH STUD PER MOUNT PL, VM,� = 93 LBS WOOD SCREWS Vn��ow= 1(180#) =180# Tn��ow = 1(293.75#) =293# OK PER MOUNT PL, TM,,,X = 129 LBS METAL STUD SCREWS Va��ow= 2(174#) =348# Ta��ow= 2(75#) =150# OK ,log: � g279 DATE: 07/07/16 JOE P. HILL, P.E. BY: Cp CHD: JPH CONSULTING STRUCTURAL ENGINEERING 1801 N. HAMPTON RD., SUITE 440 DESOTO, TX 75115-2399 972-283-5111 E-Mail:Joe@jphpe.com Page 20 of 84 0 WALL MOUNT CONNECTIONS TO WALL STUDS OPT. 2 ATTACHING UPRITE TO THE 2x4 BLOCK THROUGH WALL MOUNT BRACKET PLATE MAX. BASE SHEAR, V= 93 LBS MAX., T= 129 LBS EACH MOUNT BRACKET HAS TWO (2) WOOD SCREWS PER SCREW, VM,� = 47 LBS VALLOW - � 20 (NDS TABLE 11.M) PER SCREW, TM� = 65 LBS VALLOW > MAX V OK TALLOW ' MAX T OK REQD PER BRACKET: (2) #10 x 1-1/2"" WOOD SCREWS ATTACHING 2x4 BLOCKING TO THE WALL MAX. BASE SHEAR, V= 93 LBS Ta��ow = 114 LBS/IN (NDS TABLE 11.2B) Ta��ow = 171 LBS MAX., T = 129 LBS USE 1 5/16" LAG SCREWS @ EACH STUD (1-1/4" MIN EMB.) OR 2 #8 SELF-DRILLING DRY WALL SCREWS (ca EACH STUD PER MOUNT PL, VM,� = 93 LBS WOOD SCREWS Va��ow= 1(180#) =180# Tn��ow = 1(293.75#) =293# OK PER MOUNT PL, T� = 129 LBS METAL STUD SCREWS Va��ow= 2(174#) =348# Ta��ow= 2(75#) =15� OK ,log: � g279 DATE: 07/07/16 JOE P. HILL, P.E. BY: Cp CHD: �pH CONSULTING STRUCTURAL ENGINEERING 1801 N. HAMPTON RD., SUITE 440 DESOTO, TX 75115-2399 972-283-5111 E-Mail:Joe@jphpe.com Page 21 of 84 �x Loads: LC 1, DL+LL+SEISMIC Joe P. Hill, P.E. SK - 1 CD FRAME B-WM - LONGITUDINAL BURLINGTON � NODE, MEMBER AND LOADING LAYOUT I FRAME B-WM.r3d �Company : Joe P. Hill, P.E. O Designer : CD Job Number : BURLINGTON Model Name . FRAME B-WM - LONGITUDINAL G/oba/ Checked By: JPH RISA-3D Version 13.0.0 [C:\...\...\...\...\CALC\Frames\RISA3D\FRAME B-WM.r3d] Page P� o�f 84 �Company : Joe P. Hill, P.E. O Designer : CD Job Number : BURLINGTON Checked By: JPH Model Name . FRAME B-WM - LONGITUDINAL Global. Continued Seismic Code None Seismic Base Elevation ft Not Entered Add Base Wei ht? No Ct X .035 Ct Z .035 T X sec Not Entered T Z sec Not Entered R X - - - -- 8.5 ___ _- --- — - - -- --- ------ R Z 8.5 Genera/ Material Properties Label E ksi G ksi Nu Therm 1 E5 F Densi k/ft^3 1 RIGID 1 e+7 0 0 0 General Section Sets Member Primarv Data Joint Coordinates and Temneratures Label X ft Y ft Z ft Tem F Detach From Dia... 1 N 1 -- � - - - --- ------- � ---. -- - - -- —� -- - - -- - -�----- - _ _ ----- -- 2 N2 4 0 0 0 3 N3 0 7.5 0 0 4 N4 4 7.5 0 0 5 N5 0 _ 0.666667 0 0 � 6 N6 4 0.666667 0 0 7 N7 0 1.833333 0 0 8 N8 4 1.833333 0 0 9 N9 0 2.666667 0 0 10 N 10 4 2.666667 0 0 11 N11 0 3.5 0 0 12 N12 4 3.5 0 0 13 N13 0 4.333333 0 0 14 N14 4 4.333333 0 0 15 N 15 0 5.166667 0 0 , 16 N 16 4 5.166667 0 0 17 N17 0 6 0 0 18 N18 4 6 0 0_ __ RISA-3D Version 13.0.0 [C:\...\...\...\...\CALC\Frames\RISA3D\FRAME B-WM.r3d] Page P�$e� 84 Company : Joe P. Hill, P.E. � Designer : CD \J�1 1 Job Number : BURLINGTON Checked By: JPH Model Name : FRAME B-WM - LONGITUDINAL Joint Coordinates and Temaeratures (Continued) Joint Boundarv Conditions Joint Loads and Enforced Disalacements (BLC 2: SEISMIC) Joint Label L D M Direction Ma nitude Ib k-ft in rad Ib*s^2/ft Ib"s^2`ft 1 N 19 L X 20.46 2 N17 L X 17.97 3 N15 L X 15.47 4 N13 L X 12.98 5 N11 L X 10.48 6 N9 L X 7.98 7 N7 L X 5.49 8 -- - N5 -- --- L X 2 . - -- — - --- Member Distribufed Loads BLC 1: DL+LL) Basic Load Cases Load Combinations Descri tion Solve PD... S... BLC F... BLC F... BLC F... BLC F... BLC F... B...F... BLC F... B..F... B..F... B...F... 1 DL+LL+SEISMIC Yes 1 1 2 1 Joint Reactions RISA-3D Version 13.0.0 [C:\...\...\...\...\CALC\Frames\RISA3D\FRAME B-WM.r3d] Page P� o� 84 �Company : Joe P. Hill, P.E. O Designer : CD Job Number : BURLINGTON Checked By: JPH Model Name . FRAME B-WM - LONGITUDINAL Member Section Forces LC Member Lab... Sec Axial Ib Shea Ib z Shea Ib Tor ue k-ft - Moment k-ft z-z Moment k-ft 1_ __ 1_ M1 1 126.709 31.975 0_ _____ 0 0 0 2 2 106.659 18.558 0 0 0 -.015 3 3 78.565 9.584 0 0 0 -.02 --- 4 4 42.497 �.331 0 0 0 -.019 5 5 0 0 0 0 0 0 I 6 1 M2 1 353.291 60.855 0 0 0 0 7 2 253.341 66.782 0 0 0 .003 8 3 161.435 57.296 0 0 0 -.012 9 4 77.503 42.761 0 0 0 -.02 10 5 0 0 0 0 0 0 11 1 M3 1 5.384 15.049 0 0 0 -.01 12 2 5.384 .049 0 0 0 -.018 13 3 5.384 -14.951 0 0 0 -.01 14 4 5.384 -29.951 0 0 0 .012 15 5 5.384 -44.951 0 0 0 .05 16 1 M4 1 4.102 13.045 0 0 0 -.014 17 2 4.102 -1.955 0 0 0 -.02 18 3 4.102 -16.955 0 0 0 -.01 19 4 4.102 -31.955 0 0 0 .014 20 5 4.102 -46.955 0 0 0 .054 21 1 M5 1 -4.403 11.033 0 0 0 -.018 22 2 -4.403 -3.967 0 0 0 -.022 23 3 -4.403 -18.967 0 0 0 -.01 � 24 4 -4.403 -33.967 0 0 0 .016 25 5 �.403 -48.967_ 0 0 0 .058 � 26 1 M6 1 -1.524 9.017 0 0 0 -.022 27 2 -1.524 -5.983 0 0 0 -.024 ' 28 3 -1.524 -20.983 0 0 0 -.01 29 4 -1.524 -35.983 0 0 0 .018 I 30 5 -1.524 -50.983 0 0 0 .062 31 1 M7 1 6.778 17.062 0 0 0 -.006 32 2 6.778 2.062 0 0 0 -.016 33 3 6.778 -12.938 0 0 0 -.01 34 4 6.778 -27.938 0 0 0 .01 _ 35 _ _ _ _ __ 5 6.778 -42.938 0_ 0 0 .046 36 1 M8 1 7.757 19.006 0 0 0 -.002 37 2 7.757 4.006 0 0 0� -.014 38 3 7.757 -10.994 0 0 0 -.01 39 4 7.757 -25.994 0 0 0 .008 40 5 7.757 -40.994 0 0 0 .042 41 1 M9 1 -3.512 20.695 0 0 0 .001 42 2 -3.512 5.695 0 0 0 -.012 43 3 -3.512 -9.305 0 0 0 -.01 44 4 -3.512 -24.305 0 0 0 .007 45 5 -3.512 -39.305 0 0 0 .039 46 1 M10 1 46.273 21.803 0 0 0 .003 47 2 46.273 6.803 0 0 0 -.011 48 3 46.273 -8.197 0 0 0 -.01 49 4 46.273 -23.197 0 0 0 .005 50 5 46.273 -38.197 0 0 0 .036 RISA-3D Version 13.0.0 [C:\...\...\...\...\CALC\Frames\RISA3D\FRAME B-WM.r3d] Page P� o� 84 Company : Joe P. Hill, P.E. �Designer : CD Job Number : BURLINGTON Model Name : FRAME B-WM - LONGITUDINAL Material Takeoff Checked By: JPH RISA-3D Version 13.0.0 [C:\...\...\...\...\CALC\Frames\RISA3D\FRAME B-WM.r3d] Page P�i o� 84 0 � FRAME B-R12 LOZIER WALL MOUNT SHELVING 22•B x 48• L x 120° H WALL MOUNT ,log: 16279 DATE: 07/07/16 JOE P. HILL, P.E. BY: Cp CHD: �pH CONSULTING STRUCTURAL ENGINEERING 1801 N. HAMPTON RD., SUITE 440 DESOTO, TX 75115-2399 972-283-5111 E-Mail:Joe@jphpe.com Page 28 of 84 0 SEISMIC DESIGN FRAME B-R12 (22". B x 48"L x 120"H WALL) ASCE 7& RMI (AS IT APPLIES) I_ , EQUIVALENT LATERAL FORCE PROCEDURE FOR SHELVING . Width = 22 IN Length = 48 IN Max. Shelving Height = 120 IN SS = 1.442 S� = 0.537 Fa = 1.000 Sps = 2/3(Fa)SS = 0.961 Seismic Use Group = I �S T R CS = 1.19 Cs, MAX — SDS R Cs, MIN — �.�'44SDS SEISMIC BASE SHEAR, V= CS Ip WS LOADS DL = PL = (FIRST LEVEL) PL = 3 PSF 5 PSF 5 PSF Levels = 13 Site Class = D F„ = 1.500 Sp� = 2/3(F„)S� = 0.537 SEISMIC DESIGN CATEGORY = D T = 0.02 '' h �3�4� = 0.11 R = 4.00 (RMI Sec. 2.6.3) Ip = 1.50 (RMI Sec. 2.6.2) Cs, MAX — Cs, MIN — 0.24 « CONTROLS 0.04 TOTAL FRAME WEIGHT Ws = DL + 67%PL + 0.25LL (Per Storage Rack Section) DL = 3 PSF x 1.83 FT x 4 FT x 13 SHELVES = 286.00 LBS PL = 5 PSF x 1.83 FT x 4 FT x 12 SHELVES x 0.67 = 294.80 LBS PL = 5 PSF x 1.83 FT x 4 FT x 1 SHELVES x 0.67 = 24.57 LBS (FIRST LEVEL) WS = 605.37 LBS 0.525 x VBASE = 115 LBS IF TOP SHELF 100% LOADED ONLY, 0.525 x VTOP = 61 LBS ,1og: � 6279 DATE: 07/07/16 JOE P. HILL, P.E. BY: Cp CHD: JPH CONSULTING STRUCTURAL ENGINEERING 1801 N. HAMPTON RD., SUITE 440 DESOTO, TX 75115-2399 � 972-283-5111 E-Mail:Joe@jphpe.com Page 29 of 84 O SEISMIC DESIGN - FRAME B-R12 (CONTINUED) LEVEL W h WXhXk E W; h;k C„x FX (Ibs. ft) Ibs-ft Ibs-ft (Ibs 13 46.57 10.00 465.67 3352.80 0.14 15.91 12 46.57 9.33 434.62 3352.80 0.13 14.85 11 46.57 8.67 403.58 3352.80 0.12 13.79 10 46.57 8.00 372.53 3352.80 0.11 12.73 9 " 46.57 7.33 341.49 3352.80 0.10 11.67 8 46.57 6.50 302.68 3352.80 0.09 10.34 7 46.57 5.67 263.88 3352.80 0.08 9.02 6 46.57 4.83 225.07 3352.80 0.07 7.69 5 46.57 4.00 186.27 3352.80 0.06 6.37 4 46.57 3.17 147.46 3352.80 0.04 5.04 3 46.57 2.33 108.66 3352.80 0.03 3.71 2 46.57 1.50 69.85 3352.80 0.02 2.39 1 46.57 0.67 31.04 3352.80 0.01 1.06 TOTAL = 605.37 Ibs per rack DISTRIBUTED LATERAL FORCES Wxhxk FX=(C�x) v C„x = E W; h�k V snse = 115 LBS PsTa,ric - 605.37 Ibs per post k= 1.0 since Te <_ 0.50 E (FX * h) = 814.57 LBS-FT LW = 22 IN L� = 48 IN CONNECTION DISTANCE H= 114 IN TRANSVERSE: W = 605.37 LBS M c�,�n. = W(LW/2)/12 = 554.92 LBS-FT M seisnnic = E�FX X h) = 814.57 LBS-FT TENSION AT WALL CONNECTION = SHEAR AT WALL CONNECTION = 145 LBS 115 LBS ,106: � 6279 DATE: 07/07/16 JOE P. HILL, P.E. BY: Cp CH�: �pH CONSULTING STRUCTURAL ENGINEERING 1801 N. HAMPTON RD., SUITE 440 DESOTO, TX 75115-2399 972-283-5111 E-Mail:Joe@jphpe.com Page 30 of 84 O z���B x i2o��H UJALL MOUIN7 �'-o�� w N � � N � � � �- w LONC� ItUD INAL c i -� 4 _� cA c� cA O � O O - O � :, _ O � �, - � O O O O cA �6.57" �6.5�" �65��' �6.57�' �6.57� ��o.b�" �6.r✓- i� 46.r✓- ��' ��0.5�" 46.57" �6.5�" �65�" �6.57" � Fx113) � Fx112) � Fx111) -� Fx(10) � Fx(°I) � Fx(8) —� FxC�) � �xC6) � FxCS) � FxC4) —� Fx(3) —�— F x l2 ) � Fxl1) WALL Bl' OTHEi IUALL MOUN' tYf' � I � �'—O" � 22�� TYP. FRONt PROFILE OF FRAME "B—R12" tYP. END PROFILE OF �RAME "B—R12" .106: 16279 DATE: 07/07/16 JOE P. HILL, P.E. BY: Cp CHD: JPH CONSULTING STRUCTURAL ENGINEERING 1801 N. HAMPTON RD., SUITE 440 DESOTO, TX 75115-2399 972-283-5111 E-Mail:Joe@jphpe.com Pa e 31 of 84 OVERTURNING MOMENTS TOP SHELF LOADED - FRAME B-R12 (CONTINUED) LEVEL W h WXhXk E W; h;k C„x FX Ibs. ft Ibs-ft Ibs-ft Ibs 13 58.67 10.00 586.67 1950.67 0.30 18.37 12 22.00 9.33 205.33 1950.67 0.11 6.43 11 22.00 8.67 190.67 1950.67 0.10 5.97 10 22.00 8.00 176.00 1950.67 0.09 5.51 9 22.00 7.33 161.33 1950.67 0.08 5.05 8 22.00 6.50 143.00 1950.67 0.07 4.48 7 22.00 5.67 124.67 1950.67 0.06 3.90 6 22.00 4.83 106.33 1950.67 0.05 3.33 5 22.00 4.00 88.00 1950.67 0.05 2.75 4 22.00 3.17 69.67 1950.67 0.04 2.18 3 22.00 2.33 51.33 1950.67 0.03 1.61 2 22.00 1.50 33.00 1950.67 0.02 1.03 1 22.00 0.67 14.67 1950.67 0.01 0.46 TOTAL = 322.67 Ibs per frame DISTRIBUTED LATERAL FORCES Wxhxk FX =(C„x) V k= 1.0 since Ta <_ 0.50 C„x = E W; h�k V Tpp = G'I LBS LW = 22 IN L� = 48 IN CONNECTION DISTANCE H= 114 IN TRANSVERSE: W= 322.67 LBS LOAD TOP SHELF ONLY M cw�viTv = W(LW/2)/12 = 295.78 LBS-FT M sEisnnic =��FX x h) = 467.35 LBS-FT TENSION AT WALL CONNECTION = 81 LBS SHEAR AT WALL CONNECTION = 62 LBS ,log: � 6279 DATE: 07/07/16 JOE P. HILL, P.E. BY: Cp cH�: JPH CONSULTING STRUCTURAL ENGINEERING 1801 N. HAMPTON RD., SUITE 440 DESOTO, TX 75115-2399 972-283-5111 E-Mail:Joe@jphpe.com Page 32 of 84 COMPONENT DESIGN FOR FRAME B-R12 NOTE:SECTION PROPERTIES LISTED ON COMPONENT DESIGN SHEETS, REFER TO APPENDIX B IN REPORT, INDICATING SHAPE, SIZE & RISA SECTION PROPERTIES FOR EACH COMPONENT. 22 IN . SHELF: LENGTH OF SHELF (L�) = 4.00 FT Fy = 45 KSI MIN. W DL+LL - �4.67 PLF MAX. M SHELF - W OL+LL X L�Z I H X � Z= 3rJZ.00 LBS-IN MAX. V SHELF -�W DL+LL X LL � 2� - 29.33 LBS REQD Sx = M sHE�F / 0.6 Fy = REQD AREA = V sHE�F / 0.4 Fy = SHELF BRACKET: TL STYLE MAX SPAN (LS) = 22 IN FROM RISA SECTION: 0.013 IN3 Ix = 0.119 IN4 Sx = 0.099 IN3 OK 0.002 INZ AREA = 0.959 INZ OK THEREFORE SHELF IS OK Fy = 70 KSI MIN. LENGTH OF SHELF (L�)= 4.00 FT WDL+LL+0.86PL =(DL+LL+O.HHPL) X L� I Z= PVERT IMPACT - WDL+LL+0.88PL X Z5% _ M�MAX� _��WDL+LL+0.88PL X LSZ � 24� +�PVERT IMPACT X LS �� - 14.8 PLF 3.7 LBS 379.87 LBS-IN V�MAX� =��WDL+LL+0.88pL X LS� '� PVERT IMPACT �- 3O.H3 LBS ASSUME ONLY TOP CLIP IN TENSION AREA = 0.951" x 0.12" = 0.11 INZ TENSION CAPACITY = AREA x 0.6Fy = 4793 LBS MOMENT CAPACITY = TENSION CAP. x 1.82 IN = 8723 LBS-IN MOMENT CAPACITY > M(MAX) OK CHECK SHEAR OF BRACKET VAi�o,�, = AREA x 0.4Fy = 3195.36 LBS OK THEREFORE SHELF BRACKET IS OK ,loB: �g279 DATE: 07/07/16 JOE P. HILL, P.E. BY: Cp CHo: �pH CONSULTING STRUCTURAL ENGINEERING 1801 N. HAMPTON RD., SUITE 440 DESOTO, TX 75115-2399 972-283-5111 E-Mail:Joe@jphpe.com Page 33 of 84 0 COMPONENT DESIGN - TRANSVERSE DIRECTION (FRAME B-R12) Yf UPRITE . � �� �� + � � SECTION PROPERTIES MAX HT = 120 IN ' T ; Fy = 55000 PSI � AREA = 0.757 INZ ly = 0.237 IN° � ; Ix = 0.817 IN4 Sy = 0.250 IN3 � i Sx = 0.630 IN3 ry= 0.560 IN � � nc= 1.039 IN S2c= 1.80 -�-,--- ---•----+------- ----- a C„� 1.0 S2b= 1.67 I ; Unbrace Lx-x = 120 IN Kx = 1.7 ; Unbrace Ly-y = 10 IN Ky = 1.0 �I � � Span (LS) = 22 IN ; - PsTa,Tic = 605.37 LBS MAX MsrnTic = PsTnric x(LS/12) / 2= 554.92 LBS-FT kLx _ 1.7 120 = 196.34 <- CONTROLS rx 1.0391 N k� _ �� = 17.86 ry 0.561 N Fa = � * E = 7425 PSI (KI/r)2 COLUMN SECTION �,c = (Fy / Fa)'�2 = 2.72 >1.5 Fn =r �'c < 1.5 (0.658'�°2>Fy = 6511 PSI l �,c > 1.5 (0.877/ �,c2)Fy Pn = AREA * F„ = 4929.06 LBS PEx = (7�EIX) / (KxLx)z = 5619.01 LBS a,� = 1- (S2�P/Pex) = 0.81 MAX MOMENT IN COLUMN Mx = MsTATic = 554.92 LBS-FT Mx = MseisMic =�iFX x h) = 814.57 LBS-FT <— CONTROLS M„ = Sx * Fy = 2887.50 LBS-FT COMBINED STRESS = fa/Fa + fb/Fb = (S2CP/P„) + (,�PC,T„�M�/M„ac,�) = 0.81 < 1.0 THEREFORE UPRITE IS OK ,loB: � 6279 DATE: 07/07/16 JOE P. HILL, P.E. BY: Cp CH�: JPH CONSULTING STRUCTURAL ENGINEERING 1801 N. HAMPTON RD., SUITE 440 DESOTO, TX 75115-2399 972-283-5111 E-Mail:Joe@jphpe.com Page 34 of 84 0 COMPONENT DESIGN - LONGITUDINAL DIRECTION (FRAME B-R12) RELATIVE SHELF STIFFNESS (22". SHELF): E= 29000 KSI S2 = 1.67 � SHELF - O.'I'I9 IN4 L� = 48 IN K sHE�F = 384EI / L�3 = 11.983 RELATIVE UPRITE STIFFNESS: � UPRITE - O.Z37 �N° UNBRACED H= 10 IN K uPRi� = 24EI / H3 = 164.952 FROM RISA MODEL (SEE NEXT 4 PAGES): SHELF DESIGN: MAX. M= 0.065 K-FT (MEMBER M6 CONTROLS) MAX. MIMPACT - PVERT IMPACT � LS - 0.007 K-FT MAX. M = 0.072 K-FT Sx = 0.099 IN3 Maliow = Sx'Fy/52 = 0.222 K-FT Mallow > MAX. M OK T=C=M*12/1.82= 0.47 KIP ALLOWABLE SHEAR TO RESIST MOMENT: TAB DISTANCE = 1.82 IN TAB = 0.95 IN t= 11 GA AREA OF TAB = 0.11 INZ (SEE COMP.CALCS) FY = 70 KSI un��ow = 0.4 AREA FY = 3.18 KIP T = C < VqLLOW OK UPRITE . DESIGN: MAX UNBRACED HT (L�) _ Ls = SECTION PROPERTIES FROM RISA SECTION: AREA = 0.757 INZ MsTanc = Psrnnc �2 " �s�2 = 3329.52 IN-LBS N � T G M ��F 10 IN Fy= 22 IN Sy = 0.250 IN3 ly = 0.237 IN° ry=__ 0.560 IN F'�'id�I��1.91 � _ f0.8)(MAX H� 12 * 7� * E- 14.29 Fa = - 731724 PSI ry 0.56 23(KI/r)2 fa/Fa = (Psrnric)��AREA•Fa) = 0.001 fb/Fb = (Msrnric) � iSy'Fy/52) = 0.404 fa/Fa + �/Fb = 0.405 < 1.00 FROM RISA MODEL OF FRAME B-R12 =__> MsTnnc '* MseisMic = 45.00 LBS-FT fb/Fb =(Msrnnc+ MseisMic) � iSy'Fy/S2) = 0.066 fa/Fa + fb/Fb = 0.067 < 1.00 THEREFORE UPRITE IS OK ,loB: 16279 DATE: 07/07/16 JOE P. HILL, P.E. BY: Cp CHD: �pH CONSULTING STRUCTURAL ENGINEERING 1801 N. HAMPTON RD., SUITE 440 DESOTO, TX 75115-2399 972-283-5111 E-Mail:Joe@jphpe.com Page 35 of 84 WALL MOUNT CONNECTIONS TO CMU WALL OPT. 1 ATTACHING UPRITE TO THE 2x4 BLOCK (THROUGH UPRITE INTO BLOCK) ATTACH UPRITE TO WALL AT EVERY 1 UPRITE FRAME TYPICAL 5/16" x 4" LAG SCREW T Mnx = 145 x 1= 145 LBS (MAX. LOAD) V Max = 115 x 1= 115 LBS (MAX. LOAD) TWITHDRAWL — 235 LBS PER INCH OF THREADS (NDS TABLE 11.2A) MIN. EMBEDMENT = 1.25 IN (NDS SEC. 11.1.3) T a��ow = 293.75 LBS PER LAG SCREW TALLOW > MAX T OK USE TYPICAL 5/16" x 4" LAG SCREW (1-1/4" MIN. EMB. IN TO SOLID MATERIAL) ATTACHING 2x4 BLOCKING TO THE WALL MAX. BASE SHEAR, V= 115 LBS MAX., T= 145 LBS ANCHOR 2X4 BLOCK TO THE MASONARY WALL EACH BLOCK HAS TWO MASONARY ANCHORS. PER MOUNT PL, VM� = 115 LBS PER MOUNT PL, TM� = 145 LBS VALLOW — 5OO LBS TALLOW — 3OO LBS LBS COMBINED FORCES (Nd�N�e��5,3'+ �Vd�rec�5/3 — O.3H < 1.0 OK REQD PER 2X4 BLOCK: (2) 1/4" DIA. TITEN MASONARY ANCHORS (EMBED 1 1/2" MIN IN TO SOLID MATERIAL) **USE 1l4" DIA x 4" TITEN MASONARY SCREW ANHORS �oB: 16279 DATE: 07/07/16 JOE P. HILL, P.E. BY: Cp CHD: �pH CONSULTING STRUCTURAL ENGINEERING 1801 N. HAMPTON RD., SUITE 440 DESOTO, TX 75115-2399 972-283-5111 E-Mail:Joe@jphpe.com Page 36 of 84 WALL MOUNT CONNECTIONS TO CMU WALL OPT. 2 ATTACHING UPRITE TO THE 2x4 BLOCK THROUGH WALL MOUNT BRACKET PLATE MAX. BASE SHEAR, V= 115 LBS MAX., T= 145 LBS EACH MOUNT BRACKET HAS TWO (2) WOOD SCREWS PER SCREW, VM,� = 58 LBS PER SCREW, TM� = 73 LBS VALLOW — �ZO LBS TAuow = 114 LBS/IN (NDS TABLE 11.M) (NDS TABLE 1126) TA��ow = 171 LBS VALLOW > MAX V OK TALLOW > MAX T OK REQD PER BRACKET: (2) #10 x 1-1/2"" WOOD SCREWS ATTACHING 2x4 BLOCKING TO THE WALL MAX. BASE SHEAR, V= 115 LBS MAX., T= 145 LBS ANCHOR 2X4 BLOCK TO THE MASONARY WALL EACH BLOCK HAS TWO MASONARY ANCHORS. PER MOUNT PL, VM� = 115 LBS PER MOUNT PL, TM� = 145 LBS VALLOW — 5OO LBS TA��ow = 300 LBS LBS COMBINED FORCES (Nd/Nrec�S/3 +�VdNrec�S/3 ' O.3H < 1.0 OK REQD PER 2X4 BLOCK: (2) 1/4" DIA. TITEN MASONARY ANCHORS (EMBED 1 1/2" MIN IN TO SOLID MATERIAL) **USE 1/4" DIA x 4" TITEN MASONARY SCREW ANHORS ,1oa: 16279 DATE: 07/07/16 JOE P. HILL, P.E. BY: Cp CHD: �pH CONSULTING STRUCTURAL ENGINEERING 1801 N. HAMPTON RD., SUITE 440 DESOTO, TX 75115-2399 972-283-5111 E-Mail:Joe@jphpe.com Page 37 of 84 WALL MOUNT CONNECTIONS TO CMU WALL OPT. 3 ATTACHING UPRITE THROUGH WALL MOUNT BRACKET PLATE TO THE WALL MAX. BASE SHEAR, V= 115 LBS MAX., T= 145 LBS EACH POST HAS TWO WALL MOUNT BRACKETS (48" O.C.) PER MOUNT PL, VM,,,x = 115 LBS PER MOUNT PL, TM� = 145 LBS EACH BRACKET HAS TWO MASONARY ANCHORS. PER SCREW, VM,� = 58 LBS PER SCREW, TM� = 73 LBS VALLOW — 5OO LBS TALLOW — 3OO LBS LBS COMBINED FORCES (Nd/Nrec�S/3 +�VdNrec)5�3 = 0.12 < 1.0 OK REQD PER WALL MOUNT BRACKET: (2)1/4" DIA. TITEN MASONARY ANCHORS (EMBED 1 1/2" MIN IN TO SOLID MATERIAL) **USE 1/4" DIA x 2 1/2" TITEN MASONARY SCREW ANHORS .IOB: 16279 DATE: 07/07/16 JOE P. HILL, P.E. BY: Cp CH�: JPH CONSULTING STRUCTURAL ENGINEERING 1801 N. HAMPTON RD., SUITE 440 DESOTO, TX 75115-2399 972-283-5111 E-Mail:Joe@jphpe.com Page 38 of 84 O WALL MOUNT CONNECTIONS TO WALL STUDS OPT. 1 ATTACHING UPRITE TO THE 2x4 BLOCK (THROUGH UPRITE INTO BLOCK) ATTACH UPRITE TO WALL AT EVERY 1 UPRITE FRAME TYPICAL 5/16" x 4" LAG SCREW T Mnx = 145 x 1= 145 LBS (MAX. LOAD) V nn,nx = 115 x 1= 115 LBS (MAX. LOAD) Tv,nTH�Ra,v,a = 235 LBS PER INCH OF THREADS (NDS TABLE 11.2A) MIN. EMBEDMENT = 1.25 IN (NDS SEC. 11.1.3) T a,��ow = 293.75 LBS PER LAG SCREW TALLOW > MAX T OK USE TYPICAL 5/16" x 4" LAG SCREW (1-1/4" MIN. EMB. INTO MATERIAL) ATTACHING 2x4 BLOCKING TO THE WALL MAX. BASE SHEAR, V= 115 LBS MAX., T = 145 LBS USE 1 5/16" LAG SCREWS @ EACH STUD (1-1/4" MIN EMB.) OR 2 #8 SELF-DRILLING DRY WALL SCREWS CD EACH STUD PER MOUNT PL, VM� = 115 LBS WOOD SCREWS Vn��ow= 1(180#) =180# Tn��ow= 1(293.75#) =293# OK PER MOUNT PL, TM,� = 145 LBS METAL STUD SCREWS Vn��ow= 2(174#) =348# Ta��ow= 2(75#) =150# OK ,loB: 16279 DATE: 07/07/16 JOE P. HILL, P.E. BY: Cp CHp: �pH CONSULTING STRUCTURAL ENGINEERING 1801 N. HAMPTON RD., SUITE 440 DESOTO, TX 75115-2399 972-283-5111 E-Mail:Joe@jphpe.com Page 39 of 84 O WALL MOUNT CONNECTIONS TO WALL STUDS OPT. 2 ATTACHING UPRITE TO THE 2x4 BLOCK THROUGH WALL MOUNT BRACKET PLATE MAX. BASE SHEAR, V= 115 LBS MAX., T= 145 LBS EACH MOUNT BRACKET HAS TWO (2) WOOD SCREWS PER SCREW, VM� = 58 LBS PER SCREW, TM� = 73 LBS VALLOW - � 20 (NDS TABLE 11.M) VALLOW > MAX V OK TALLOW > MAX T OK REQD PER BRACKET: (2) #10 x 1-1/2"" WOOD SCREWS ATTACHING 2x4 BLOCKING TO THE WALL MAX. BASE SHEAR, V= 115 LBS Tn��ow = 114 LBS/IN (NDS TABLE 11.2B) Ta��ow = 171 LBS MAX., T = 145 LBS USE 1 5/16" LAG SCREWS @ EACH STUD (1-1/4" MIN EMB.) OR 2 #8 SELF-DRILLING DRY WALL SCREWS CD_ EACH STUD PER MOUNT PL, VM,� = 115 LBS WOOD SCREWS Va��ow= 1(180#) =180# Ta��ow= 1(293.75#) =293# OK PER MOUNT PL, TM� = 145 LBS METAL STUD SCREWS Vn��ow= 2(174#) =348# TA��ow= 2(75#) =150# OK ,IOB: � 6279 DATE: 07/07/16 JOE P. HILL, P.E. BY: Cp CH�: JPH CONSULTING STRUCTURAL ENGINEERING 1801 N. HAMPTON RD., SUITE 440 DESOTO, TX 75115-2399 972-283-5111 E-Mail:Joe@jphpe.com Page 40 of 84 �x -.o�zWrc 15.9' 14.E 13. Loads: LC 1, DL+LL+SEISMIC Joe P. Hill, P.E. SK - 1 CD FRAME B-R12 - LONGITUDINAL BURLINGTON � NODE, MEMBER AND LOADING LAYOUT I FRAME B-R12.r3d Company : Joe P. Hill, P.E. �,�� Designer : CD LJo ��t I Job Number : BURLINGTON Model Name : FRAME B-R12 - LONGITUDINAL Global Checked By: JPH RISA-3D Version 13.0.0 [C:\...\...\...\...\CALC\Frames\RISA3D\FRAME B-R12.r3d] page P� o�f 84 Company : Joe P. Hill, P.E. � Designer : CD VI�1 I Job Number : BURLINGTON Checked By: JPH � Model Name : FRAME B-R12 - LONGITUDINAL Global. Continued General Material Proaerties Label E ksi G ksi Nu Therm \1 E5 F Densi k/ft^3 1 RIGID 1e+7 0 0 0 Genera/ Section Sets Member Primarv Data Joint Coordinaies and Temperatures Label X ft Y ft Z ft Tem F Detac From Dia... 1_ N1 0 0 _----- . 0 0 , 2 N2 4 _ 0 0 -__ � 3 - ------ N3---- ----_ _ _..._ ---�----- 10 0 0 _-_ , 4 N4 4 10 0 0 5 N 5 0 0.666667 _ 0 0 6 N6 __ .. _ 4 _ - -- -- 0.666667 _ . _ _ _ . 0 0 -7-- --- - N7 . 0 1.5 0 0_ - - ----- , 8 N8 4 1.5 _ _0 - -- - -- -- � --- - — 9 _N9 ____ 0 2.333333 0 0 � 10 N10 4 2.333333 0 0 11 N 11 0 3.166667 0 0 12 N12 4 3.166667 0 0 13 N13 0 4 0 0 RISA-3D Version 13.OA [C:\...\...\...\...\CALC\Frames\RISA3D\FRAME B-R12.r3d] Page P�e� 84 Company : Joe P. Hill, P.E. ��� Designer : CD �.JI�1 1 Job Number : BURLINGTON Checked By: JPH Model Name : FRAME B-R12 - LONGITUDINAL Joint Coordinates and Temaeratures (Continuedl Label X ft Y ft Z ft Tem F Detach From Dia... 14 N14 4 4 0 0 15 N15 0 4.833333 0 _ 0_ - -- - - _-- _ 16 N16 4 4.833333 0 0 17 N17 ___ 0 __ _ _5.666667 _ ___ __ 0 0 18 N 18 4 5.666667 0 0 19 - -N19_ ------ 0 6.5 0 . - ---- -- --- __ _ _ ---- - - � 20 N20 4 6.5 0 0 21 N21 0 7.333333 0 0 22 N22 4 7.333333 0 0 23 N23 0 8 0 0 24 N24 4 8 0 0 25 N25 _ 0 8.666667 0 0 26 N26 4 8.666667 0 0 27 N27 0 9.333333 0 0 28 N28 4 9.333333 0 0 Joinf Boundarv Conditions Joint Loads and Enforced Disalacements (BLC 2; SE/SMIC) Joint Label L D M Direction Ma nitude Ib k-ft in rad Ib*s^2/ft Ib's^2`ft 1 N3 L X 15.91 2 N27 L X 14.85 3 N25 L X 13.79 4 N23 L X 12.73 5 N21 L X 11.67 6 N19 L X 10.34 7_ N17 L X 9.02 � 8 ----- - N15 L X 7.69 9 N13 _------ -----�-------- ---- X------ - - ----- - 6.37 -------- ---- ' 10 N 11 L X 5.04 11 N9 L X 3.71 12 N7 L X 2.39 13 N5 L X 1.06 Member Distributed Loads (BLC 1: DL+LL) Member ... Direction Start Ma nitude k/ft End Ma nitude k/ft Start Locatio... End Location ft% 1 M3 Y -.012 -.012 0 0 2 M4 Y -.012 -.012 0 0 3 M5 Y -.012 -.012 0 0 � 4 M6 Y -.012 -.012 0 0 5 M7 Y -.012 -.012 0 0 6 M8 Y -.012 -.012 0 0 7 M9 Y -.012 -.012 0 0 8 M10 -_ - Y -.012 -.012 0 0 9 M 11 Y -.012 -.012 0 0 10 M12 Y -.012 -.012 0 0 11 M13 Y -.012 -.012 0 0 , 12 M 14 Y -.012 -.012 0 0 13 M 15 Y -.012 -.012 0 0 RISA-3D Version 13.0.0 [C:\...\...\...\...\CALC\Frames\RISA3D\FRAME B-R12.r3d] page P4�� o�' 84 Company : Joe P. Hill, P.E. � Designer : CD V�1 I Job Number : BURLINGTON Checked By: JPH Model Name : FRAME B-R12 - LONGITUDINAL Basic Load Cases Load Combinations Descri tion Solve PD... S... BLC F... BLC F... BLC F... BLC F... BLC F... B...F... BLC F... B..F... B..F... B...F... 1 DL+LL+SEISMIC Yes 1 1 2 1 Joint Reactions Member Section Forces LC Member Lab... Sec Axial Ib Shea Ib z Shea Ib Tor ue k-ft - Moment k-ft z-z Moment k-ft 1 1 M 1 1 108.372 46.127 0 0 0 0 2 2 106.764 34.65 0 0 0 -.005 3 3 93.381 25.073 0 0 0 -.013 4 4 63.64 5.051 0 0 0 -.024 5 5 17.496 -26.724 0 0 0 .003 6 1 M2 1 515.628 68.443 0 0 0 0 7 2 373.236 72.76 0 0 0 .005 8 3 242.619 63.237 0 0 0 -.004 9 4 128.36 52.229 0 0 0 -.016 10 5 30.504 42.634 0 0 0 -.029 11 1 M3 1 2.5 2.989 0 0 0 -.026 12 2 2.5 -9.011 0 0 0 -.023 13 3 2.5 -21.011 0 0 0 -.008 14 4 2.5 -33.011 0 0 0 .019 15 5 2.5 -45.011 0 0 0 .058 16 1 M4 1 2.039 1.725 0 0 0 -.029 17 2 2.039 -10.275 0 0 0 -.024 18 3 2.039 -22275 0 0 0 -.008 19 4 2.039 -34.275 0 0 0 .02 20 5 2.039 -46.275 0 0 0 .06 21 1 M5 1 1.483 .542 0 0 0 -.031 22 2 1.483 -11.458 0 0 0 -.026 23 3 1.483 -23.458 0 0 0 -.008 24 4 1.483 -35.458 0 0 0 .021 _25 _ _ 5 1.483 -47.458 0 0 0_ ___ __ .063 26 1 M6 1 -7.839 -.659 _ - 0 - - - - -- 0. -- -- - - 0 -.033 27 2 -7.839 -12.659 0 0 0 -.027 28 3 -7.839 -24.659 0 0 0 -.008 29 4 -7.839 -36.659 0 0 0 .023 - -- - 30 5 -7.839 -48.659 0 0 0 .065 31 1 M7 1 3.179 4.399 0 0 0 -.023 _ _ __ � 32 2 3.179 -7.601 0 - - - - 0 - - - ---- - 0 - - -- - - --- - 022 - - 33 3 3.179 -19.601 0 0 0 -.008 � 34 4 3.179 -31.601 0 0 0 .017 35 5 3.179 -43.601 0 0 0 .055 RISA-3D Version 13.0.0 [C:\...\...\...\...\CALC\Frames\RISA3D\FRAME B-R12.r3d] Page P4�e0� 84 Company : Joe P. Hill, P.E. . � Designer : CD V�JI 1 Job Number : BURLINGTON Checked By: JPH Model Name : FRAME B-R12 - LONGITUDINAL Member Section Forces (Continued) LC Member Lab... Sec Axial Ib Shea Ib z Shea Ib Tor ue k-ft - Moment k-ft z-z Moment k-ft 36 1 M8 1 3.844 5.996 0 0 0 -.02 37 2 3.844 -6.004 0 0 0 -.02 38 - _ _ _- - - - - 3 -- - 3.844 -18.004 0 0 0 -.008 __ 39 4 3.844 -30.004 0 0 0 .016 - - - ._---- _ - --- -- 40 5 3.844 -42.004 0 0 0 .052 41 1 M9 1 4.635 7.804 0 0 0 -.016 - - - -- 42 2 4.635 �.196 0 0 0 -.018 43 3 4.635 -16.196 0 0 0 -.008 44 4 4.635 -28.196 0 0 0 .014 45 5 4.635 -40.196 0 0 0 .048 46 1 M10 1 4.908 9.838 0 0 0 -.012 47 2 4.908 -2.162 0 0 0 -.016 48 3 4.908 -14.162 0 0 0 -.008 49 4 4.908 -26.162 0 0 0 .012 i 50 5 4.908 -38.162 0 0 0 .044 51 1 M 11 1 1.466 12.099 0 0 0 -.008 i 52 2 1.466 .099 0 0 0 -.014 53 3 1.466 -11.901 0 0 0 -.008 54 4 1.466 -23.901 0 0 0 .01 55 5 1.466 -35.901 0 0 0 .04 56 1 M 12 1 6.312 13.913 0 0 0 -.004 57 2 6.312 1.913 0 0 0 -.012 58 3 6.312 --10.087 0 . 0 0 -.008 59 4 6.312 -22.087 0 0 0 .008 60 5 6.312 -34.087 0 0 0 .036 61 1 M13 1 5.384 15.49 0 0 0 -.001 62 2 5,384 3.49 0 0 0 -.011 63 3 5.384 -8.51 0 0 0 -.008 64 4 5.384 -20.51 0 0 0 .006 65 5 5.384 -32.51 0 0 0 .033 66 1 M 14 1 -2.101 16.74 0 0 0 .001 67 2 -2.101 4.74 0 0 0 -.009 68 3 -2.101 -7.26 0 0 0 -.008 69 4 -2.101 -19.26 0 0 0 .005 70 5 -2.101 -31.26 0 0 0 .03 71 1 M15 1 42.634 17.496 0 0 0 .003 72 2 42.634 5.496 0 0 0 -.009 73 3 42.634 -6.504 0 0 0 -.008 � 74 4 42.634 -18.504 0 0 0 .004 75 5 42.634 -30.504 0 0 0 .029 Maierial Takeoff RISA-3D Version 13.0.0 [C:\...\...\...\...\CALC\Frames\RISA3D\FRAME B-R12.r3d] Page P4�eo� 84 O FRAME E1 WIDESPAN SHELVING 36•B x 96°L x 144•H .log: � 6279 DATE: 07/07/16 JOE P. HILL, P.E. BY: Cp CHD: JPH CaNSULTING STRUCTURAL ENGINEERING 1801 N. HAMPTON RD., SUITE 440 DESOTO, TX 75115-2399 972-283-5111 E-Mail:Joe@jphpe.com Page 47 of 84 0 SEISMIC DESIGN 36"W x 96"L x 144"H WIDE SPAN FRAME E1 ASCE 7& RMI (AS IT APPLIES) EQUIVALENT LATERAL FORCE PROCEDURE FOR SHELVING Width = 36 IN Length = 96 IN Max. Shelving Height = 144 IN SS = 1.442 S� = 0.537 Fa = 1.000 SpS = 2/3(Fa)SS = 0.961 Levels = 3 Site Class = D F„ = 1.500 Sp� = 2/3(F„)S� = 0.537 Seismic Use Group = I SEISMIC DESIGN CATEGORY = D T= 0.02*h�"4�= 0.13 CS _ Sp� R= 4.00 (RMI Sec. 2.6.3) T R Ip = 1.50 (RMI Sec. 2.6.2) S2o = 2.0 (ASCE 7 Table 15.4-1) CS = 1.04 SDS C5' nn,vc R Cs, MIN — 0.O44SDS SEISMIC BASE SHEAR, V= CS IP WS LOADS DL = 5 PSF/SHELF RATED LOAD PL = 180 LBS/SHELF CS, M,� _ Cs, MIN — 0.24 « CONTROLS 0.04 TOTAL FRAME WEIGHT Ws = DL + 67%PL + 0.25LL (Per Storage Rack Section) DL = 5 PSF x 3 FT x 8 FT x 3 SHELVES = 360.00 POUNDS SHELVING PL = 180 LBS/SHELF x 0.67 x 3 SHLVS = 361.80 POUNDS SHELVING WS = 721.80 LBS 0.525 x VBASE _ IF TQP SHELF 100% LOADED ONLY, 0.525 x VTOP = 137 LBS 102 LBS ,loB: 16279 DATE: 07/07/16 JOE P. HILL, P.E. BY: Cp CHD: JPH CONSULTING STRUCTURAL ENGINEERING 1801 N. HAMPTON RD., SUITE 440 DESOTO, TX 75115-2399 972-283-5111 E-Mail:Joe@jphpe.com Page 48 of 84 0 SEISMIC DESIGN - (CONTINUED) FRAME E1 W5 = 721.80 Ibs PM,ix = 360.90 Ibs per post DISTRIBUTED LATERAL FORCES WXhxk FX, (C„x) v C�x = EW;hk V ense = 137 LBS COMP.M„� = 450.00 Ibs per post k= 1.0 since Te <_ 0.50 E (Fx' h) = 1274.05 LBS-FT UPLIFT FORCES (RMI Sec. 2.1.3 Sismic Uplift) W = (0.6-0.11 Sps)DL + (0.6-0.14Sps)PL LW = 36 IN L� = 96 IN TRANSVERSE: W = 429.25 LBS M c�,�n. = W(LW/2)/12 = 643.88 LBS-FT M seisMic = EiFX x h) 520= 2548.10 LBS-FT M cw,v�n � M SEISMIC NG HOLD DOWNS ARE REQD TENSION= 635 LBS (UPLIFT) LONGITUDINAL: W = 429.25 LBS M cruviTv = W i���2)�� 2= 1717.02 LBS-FT M seisMic = EiFx x h) S2o= 2548.10 LBS-FT M cruv�n � M SEISMIC NG HOLD DOWN ARE REQD TENSION= 104 LBS (UPLIFT) ,1oB: � 6279 DATE: 07/07/16 JOE P. HILL, P.E. BY: Cp CH�: JPH CONSULTING STRUCTURAL ENGINEERING 1801 N. HAMPTON RD., SUITE 440 DESOTO, TX 75115-2399 972-283-5111 E-Mail:Joe@jphpe.com Page 49 of 84 � � m � � � � 144"N WIDESPAN 2��_�00# � � q6 �� tYP. FRONT PROFILE OF FRAME "EI" LE1�L 3 / � LE1rE T / F x l3) Fx C2) Fx C1) 36" TYP. END PROFILE OF FRAME "�I" .log: 16279 DATE: 07/07/16 JOE P. HILL, P.E. BY: Cp CH�: JPH CONSULTING STRUCTURAL ENGINEERING 1801 N. HAMPTON RD., SUITE 440 DESOTO, TX 75115-2399 972-283-5111 E-Mail:Joe@jphpe.com Page 50 of 84 0 OVERTURNING MOMENTS TOP SHELF LOADED - FRAME E1 DISTRIBUTED LATERAL FORCES WXhXk FX= (C�x) V k= 1.0 Since Ta <_ 0.50 C„x = E W; h�k V Tpp = � OL LBS UPLIFT FORCES (RMI Sec. 2.1.3 Sismic Uplift) W = (0.6-0.11 Sos)DL + (0.6-0.14Sps)0.75xPL L,�, = 36 I N L� = 96 IN TRANSVERSE: W= 240.76 LBS LOAD TOP SHELF ONLY M cRnviTv = W iLW/2)/12 = 361.14 LBS-FT M seisMic =�iFX x h) S2o= 2082.51 LBS-FT M GRAVITY � M SEISMIC NG HOLD DOWNS ARE REQD TENSION= 574 LBS (UPLIFT) LONGITUDINAL: W= 240.76 LBS LOAD TOP SHELF ONLY M cRnwrv = W����2)��2 = 963.05 LBS-FT M seisMic =��FX x h) S2o= 2082.51 LBS-FT M GRAVITY � M SEISMIC NG HOLD DOWN ARE REQD TENSION= 140 LBS (UPLIFT) ,loB: � 6279 DATE: 07/07/16 JOE P. HILL, P.E. BY: Cp CHD: �pH CONSULTING STRUCTURAL ENGINEERING 1801 N. HAMPTON RD., SUITE 440 DESOTO, TX 75115-2399 972-283-5111 E-Mail:Joe@jphpe.com Page 51 of 84 0 BEAM DESIGN FOR FRAME E1 SECTION PROPERTIES: MAX L = 96 IN H = 3.25 IN t = 16 GA AREA = 0.439 IN2 Ix = 0.621 IN° Sx = 0.342 IN3 rx = 1.190 IN MAX ALLOWABLE LOAD - BENDING: Fy = 45000 PSI ly = 0.128 IN4 Sy = 0.108 IN3 ry = 0.540 I N (AISI Sec. C3.1.3) Mn (MAX) = 0.6 * Sx * Fy = 9223.2 LBS-IN CAPACITY = 2( 8" M/ L) = 1537.20 LBS MAX ALLOWABLE LOAD - DEFLECTION (L/180): (RMI Sec. 5.3) ALLOW DEFLECTION = 5wL4 / 384 E I CAPACITY = 2[(384 E I) /(5*180*L2) ]= 1668.57 LBS BEAM SECTION MAXIMUM STATIC ALLOWABLE LOAD PER LEVEL= 1537.20 LBS ALLOWABLE AND ACTUAL BENDING MOMENT PER LEVEL (RMI Sec.2.1.5 & 2.3) MAX BENDING MOMENT Wstatic =(DL + LL + 0.88PL) / 96" = 2.90 LBS/IN MSTATIC (DL + LL + 0.88PL) - WSTATIC LZ �$- 3340.$O LBS-I N PVERTICAL IMPACT' WStatIC X Z�J% = H.%O LBS MVERTICAL IMPACT- PVERTICAL IMPACT X L I4 = ZOH.HO LBS-IN MsTa,Tic+iMPacT= 3549.60 LBS-IN ALLOWABLE BENDING MOMENT Ma,��ow�srnTic>= 18446.40 LBS-IN MSTATiC+IMPACT � MALLOW(STATIC) OK �og: � 6279 DATE: 07/07/16 JOE P. HILL, P.E. BY: Cp CHD: JPH CONSULTING STRUCTURAL ENGINEERING 1801 N. HAMPTON RD., SUITE 440 DESOTO, TX 75115-2399 972-283-5111 E-Mail:Joe@jphpe.com Page 52 of 84 SECTION PROPERTIES AREA = Ix = Sx = rx = Cmz Unbrace Lx = Unbrace Ly = O COLUMN DESIGN FOR FRAME E1 MAX HT = 144 IN 0.372 INz ly = 0.133 IN" 0.202 IN4 Sy = 0.151 IN3 0.231 IN3 ry= 0.597 IN 0.738 IN S2c= 1.80 1.00 S2b= 1.67 72 IN Kx = 1.7 37 IN Ky = 1.0 PsTnTic = 360.90 LBS MAX COLUMN SECTION kLx _ � •L�1 = 165.85 <-- CONTROLS rx 0.7381N � — �� = 61.98 ry 0.5971N Fa = � * E = 10405 PSI (KI/r)2 �,c = (Fy / Fa)'�2 = 2.19 >1.5 Fn =f �'c < 1.5 (0.658 ��Z�Fy _ g125 PSI l �c > 1.5 (0.877/ �,c2)Fy Pn = AREA * F� = 3394.61 LBS Pex = (�ZE�x) � �Kx�x)2 = 3859.10 LBS ax = 1— (S2�P/Pex) = 0.83 MAX MOMENT IN COLUMN Mx = Msrnric + Mseisnnic = 360.00 LBS-FT M„= Sx' Fy = 962.50 LBS-FT My = MsT,aric + MseisMic = 1.00 LBS-FT M�y = Sy' Fy = 629.17 LBS-FT COMBINED STRESS = fa/Fa + fb/Fb = (SLCP/Pn) + ��pCmxMx�MnoSc) + (S2bCmyMy/M�vay) = 0.95 < 1.0 THEREFORE UPRITE IS OK ,10g: 16279 DATE: 07/07/16 JOE P. HILL, P.E. BY: Cp CH�: JPH CONSULTING STRUCTURAL ENGINEERING 1801 N. HAMPTON RD., SUITE 440 DESOTO, TX 75115-2399 972-283-5111 E-Mail:Joe@jphpe.com Pa e 53 of 84 0 TRANSVERSE BRACINGS FRAME E1 SECTION PROPERTIES: Vense = 137 HORIZONTAL BRACINGS: AREA = 0.115 INZ rX = 0.453 IN d = 36 IN k�X _ (0.81(361M rX 0.4531N k�x < rX Fa = "2E — (kl/r)2 fa VgqSE Fa AREA x Fa = 0.017 = 63.58 200 OK 70812 PSI < 1.0 OK DIAGONAL BRACING: AREA = 0.115 INZ rX = 0.453 IN d = 36 IN I = 38 IN THE LENGTH OF THE BRACE: � _ �dz+ �z�o.s _ 4.36 FT L = 52.35 IN UDIAG - VBASE �(LENGTH OF THE BRACE/ DEPTH) = 199 LBS k�X _ (1)(52.351M = 115.55 �X 0.4531N k�X < 200 OK rX 2 Fa = �k�� �2 21436 PSI fa VDIAG Fa AREA x Fa = 0.081 < 1.0 OK �oB: 16279 DATE: 07/07/16 JOE P. HILL, P.E. BY: Cp cHp: �pH CONSULTING STRUCTURAL ENGINEERING 1801 N. HAMPTON RD., SUITE 440 DESOTO, TX 75115-2399 972-283-5111 E-Mail:Joe@jphpe.com Page 54 of 84 BEAM TO COLUMN CONNX FRAME E1 BEAM TO COLUMN CONNECTION PROVIDE ADEQUATE MOMENT CAPACITY TO STABLIZE THIS SYSTEM, ALTHOGH IT DOES NOT PROVIDE 100% FIXITY. THUS, THE BEAMS WILL BE ANALYSED ASSUMING THEY HAVE PINNED ENDS. FOR THE COMPUTATION OF BEAM TO COL. MOMENT CAPACITY, THE PARTIAL FIXITY OF THE BEAM,(ASSUMED AT AN ARBITRARY 25% OF THE FIXED END MOMENT OR 2000 IN-LB WHICH EVER IS SMALLER) WILL BE ADDED CAPACITY OF CONNECTOR: BEAM LOCKING DEVICE (TWO CLIPS) (RMI 7.1.2) AREA = 7/16 " 0.03 *2 = 0.026 INZ Fy = 50000 PSI Fv=2*0.4*A*Fy VM� = 1050 LBS >1000 LBS OK BEAM TO BRACKET WELD CAPACITY 1/8"'' 14.84 KSI = 1855 LBS/IN <— CONTROLS 0.061" " 26 KSI * 1.33 = 2109 LBS/IN �we�� = 3 IN CAPACITY = 5565 LBS a) SHEAR CAPACITY OF 1/2" TAB AREA = 0.105" * 1/2" = 0.053 INZ Fy = 50000 PSI Fv= 0.4"A*Fy VM� = 1050 LBS b) BEARING ON COLUMN D = 0.420 I N t = 0.072 IN BEARING AREA = t* D= 0.030 IN2 Fy = 50000 PSI PMax eea,Rirvc = BRG AREA * 1.2 * Fy = 1814 LBS SINCE SHEAR GOVERNS P1 = 1050 LBS �UPPGR � W .,e. M CONN CAPACITY — 1P� * 2") = 2100 LBS-IN M coNN seisMic = 1.33 * M CONN CAPACITY — 2793 LBS-IN FROM MODEL RISA MMnxeEAMzSi = 984 LBS-IN < M CONN SEISMIC OK ,log: 16279 DATE: 07/07/16 JOE P. HILL, P.E. BY: Cp CHp: �pH CONSULTING STRUCTURAL ENGINEERING 1801 N. HAMPTON RD., SUITE 440 DESOTO, TX 75115-2399 972-283-5111 E-Mail:Joe@jphpe.com Page 55 of 84 � W J W J � J �' 0 � � W O d � X J = (7 m Z } � � � N J � � m �Company : Joe P. Hill P.E. O Designer : CD Job Number : BURLINGTON � Checked By: JPH Model Name . FRAME E1 Global RISA-3D Version 13.0.0 [C:\...\...\...\...\CALC\Frames\RISA3D\3D-WS-FRAME-E1-R19.r3d] Page P6� of 84 �Company : Joe P. Hill P.E. O Designer : CD Job Number : BURLINGTON Checked By: JPH Model Name : FRAME E1 Global, Continued Seismic Code None Seismic Base Elevation ft Not Entered Add Base Wei ht? Yes Ct X .02 Ct Z .02 T X sec Not Entered T Z sec Not Entered RX - —_. _. . . _ . _ _— -- 3_ _ _ _ --- RZ 3 Hot Rolled Steel ProQerties Hot Rolled Steel Section Sets Label Sha e T e Desi n List Material Desi n...A in2 I in..Ju in...J in4 1 BM WS BEAM SECTION 16... 822111 Channel A36 Gr.36 Typical .439 .128 .621 .0005.. Member Primarv Data RISA-3D Version 13.0.0 [C:\...\...\...\...\CALC\Frames\RISA3D\3D-WS-FRAME-E1-R19.r3d] Page P6a4ed�f 84 �Company : Joe P. Hill P.E. O Designer : CD Job Number : BURLINGTON Checked By: JPH Model Name . FRAME E1 Member Primarv Data (Continued) Member Advanced Data Label I Release J Release I Offset in J Offset in T/C Onl Ph sical TOM Inactive Seismic Desi ... 1 M1 Yes None --_ . -- I 2 M2 Yes None 3 M3 Yes None 4 M4 Yes None 5 M5 Yes None _ --- -- 6 M6 Yes None 7 M7 Yes _ _ None 8 M8 _ _. Yes None 9 M9 _ __ Yes None ---- -- --- ---- — - - - -- --_ . 10 M10 Yes None 11 M11 Yes None i 12 M12 Yes None 13 M13 Yes None_ 14 M14 Yes _ None 15 M15 _______ Yes None I 16 M16-- ---- ---- — ---- ---Yes--- None 17 M17 Yes None 18 M18 - ---- Yes _ --- None -- 19 M19 Yes None__ 20 M20 Yes None 21 M21 Yes None - -- _ _ _ _ 22 M22 Yes None 23 M23 Yes None 24 M24 Yes None 25 M25 Yes None 26 M26 Yes None _ 27 M27 Yes None _ _ _ ---. --... -- -- --- __ _ ' 28 M28 Yes None 29 M29 Yes None - - --- ---.-._ . 30 M30 Yes None 31 M31 _ Yes None _----- - - - _ _ 32 M32 Yes None 33 M33 Yes None 34 M34 Yes None_ 35 M35 Yes _ None _ - - --- -- -------- 36 _ M36 Yes None 37 M37 Yes None - __ _ _. 38 M38 Yes None 39 M39 Yes None RISA-3D Version 13.0.0 [C:\...\...\...\...\CALC\Frames\RISA3D\3D-WS-FRAME-E1-R19.r3d] page Pb�i o� 84 Company : Joe P. Hill P.E. �Designer : CD Job Number : BURLIN�TON Checked By: JPH Model Name : FRAME E1 Joint Coordinates and Temaeratures Label X fl Y ft Z ft Tem F Detach From Dia... 1 N1 0 0 0 0 2 __ N2 8- 0 __ p p _. 3 N3 0 .333 0 0 4 _ N4 - __ 8 - - .333 -- � - - � 5 N5 0 12 0 0 - 6 N6 8 -__ 12 0 ---- -� 7 N7 8 0 3 0 '� 8 N8 8 12 3 0 9 N9 8 .5 0 0 10 N10 8 .5 3 0 11 N 11 8 .958 3 0 12 N 12 8 4.167 0 0 13 N 13 8 4.167 3 0 i 14 N 14 8 3.708 0 0 15 N 15 8 7.833 0 0 16 N 16 8 7.833 3 0 17 N17 0 0 3 0 � 18 N18 0 12 3 0 19 N19 0 .5 0 0 i 20 N20 0 .5 3 0 21 N21 0 .958 3 0 ! 22 N22 _ 0 4.167 0 0 23 N23 0 4.167 3 0 I 24 N24 0 3.708 0 0 25 N25 0 7.833 0 0 ' 26 N26 0 7.833 3 0 27 N27 16 0 0 0 I28 N28 16 .333 0 0 29 N29 16 12 0 0 � 30 N30 16 0 3 0 31 N31 16 12 3 0 _ - 32 N32 16 .5 0 0 33 N33 16 .5 3 0 34 N34 16 .958 3 0 35 N35 16 4.167 0 0 36 N36 16 4.167 3 0 37 N37 16 3.708 0 0 38 N38 16 7.833 0 0 39 N39 16 7.833 3 0 40 N40 8 11.5 0 0 41 N41 8 11.5 3 0 42 N42 8 11.042 0 0 43 N43 8 8.292 3 0 44 N44 0 11.5 0 0 45 N45 0 11.5 3 0 46 N46 0 11.042 0 0 47 N47 0 8.292 3 0 48 N48 16 11.5 0 0 49 N49 16 11.5 3 0 50 N50 16 11.042 0 0 51 N51 16 8.292 3 0 52 N52 0 6.333 0 0 53 N53 8 6.333 0 0 _ ___ 54 N54 0 6.333 3 0 55 N55 8 6.333 3 0 56 N56 16 6.333 0 0 KISA-3U Version 13.0.o [G:\...\...\...\...\GALC\Frames\RISA3D\3D-WS-FRAME-E1-R19.r3d] Page P6� o� 84 Company : Joe P. Hill P.E. � Designer : CD V��t I Job Number : BURLINGTON Checked By: JPH Model Name : FRAME E1 Joint Coordinates and Temperatures (Continued) Label X ft Y ft Z ft Tem F Detach From Dia... 57 N57 16 6.333 3 0 58 N58 0 9.083 0 0 59 N59 8 9.083 0 0 60 N60 0 9.083 3 0 61 N61 8 9.083 3 0 62 N62 16 9.083 0 0 63 N63 16 - -9.083--- --- - 3 --- ----- - -- _ �--- - -- - _ . 64 --- N64 8 4.625 3 0 65 --___ _ N65 8 7.375 0 _0 _ __ __-- 66 N66 0 4.625 3 0 67 N67 0 7.375 0 0 68 N68 16 ----4.625 -- - 3 . 0 69 N69 16 7.375 0 0 Joint Boundarv Conditions Joint Loads and Enforced Displacements (BLC 2: EL)C) Joint Label L D M Direction Ma nitude Ib Ib-ft in rad Ib`s^2/ft Ib"s^2*ft 1 N5 L__ _ _ X 14.96 � 2 N 18 L X 14.96 3 N6 L X 14.96 4 N8 L X 14.96 5 - - N6 L -X --- -- -- - -----14.96--- - ---------- 6 N8 L X 14.96 7 N29 - --- _--- -----� .- -. _ _ _ _ X 14.96 8 N31 L X 14.96 9 N58 L X - _ _ -- -19.38 _ _ - - - -- -- - -- ---- _- 10 N60 L X 11.38 11 N59 __ L_______ _ X_ 11.38 ! 12 • N61 L X 11.38 13 N59 L X _ - 11.38 - --------- 14 ---- - N61 --- L X 11.38 15 N62 _ L X _ 11.38 ---- ------- _ 16 N63 L X 11.38 17 N52 L X 7.81 18 N54 L X 7.81 19 N53 L X_ 7.81 - ----- ---- - -- ----- ------ - .. _ _ 20- ---. __ _ - -N55 L X 7.81 21 N53 _ L X 7.81 - -- ---- — - -- - - - � 22 N55 L X 7.81 23 N56 L X 7.81 ' 24 N57 L - X _ 7.81 Joint Loads and Enforced Displacements (BLC 3: ELZ) Joint Label L D M Direction Ma nitude Ib Ib-ft in rad Ib`s^2/ft Ib's^2*ft 1 N5 L Z 14.96 RISA-3D Version 13.0.0 [C:\...\...\...\...\CALC\Frames\RISA3D\3D-WS-FRAME-E1-R19.r3d] page P�$ o� 84 Company : Joe P. Hili P.E. � Designer : CD \./1�1 I Job Number : BURLINGTON Checked By: JPH � Model Name : FRAME E1 Joinf Loads and Enforced Disalacements (BLC 3: ELZ) (Continued) __ Joint Label L D M Direction Ma nitude Ib Ib-ft in rad Ib's^2/ft Ib's^2'ft - _ - -_ _ 2 N 18 L Z 14.96 3 N6 L Z 14.96 __. __ __ - ----- - - - _ 4 N8 L Z 14.96 5 N6 L Z 14.96 - - ._---___ __ 6 N8 L - - - Z --14.96-- 7 N29 L Z 14.96 -- _ --- -- 8 N31 __ _ � Z_- -- _..-- - 14.96 9 N58 L Z 11.38 10 N60 L Z 11.38 11 N59 L Z 11.38 12 N61 L Z 11.38 13 N59 L Z 11.38 14 N61 L Z 11.38 15 N62 L Z 11.38 16 N63 L Z 11.38 17 N52 L Z 7.81 18 N54 L Z 7.81 19 N53 L Z 7.81 20 N55 L Z 7.81 21 N53 L Z 7.81 22 N55 L Z 7.81 23 N56 L Z 7.81 24 N57 L Z 7.81 Member Distributed Loads fBLC 1: DL+LL) Basic Load Cases Load Combinations RISA-3D Version 13.0.0 [C:\...\...\...\...\CALC\Frames\RISA3D\3D-WS-FRAME-E1-R19.r3d] Page P6�e0� 84 �Company : Joe P. Hiil P.E. O Designer : CD Job Number : BURLINGTON Checked By: JPH Model Name . FRAME E1 EnveloAe Joint Reactions Enveloae Member Section Forces RISA-3D Version 13.0.0 [C:\...\...\...\...\CALC\Frames\RISA3D\3D-WS-FRAME-E1-R19.r3d] page P6� of 84 Company : Joe P. Hill P.E. �Designer : CD Job Number : BURLINGTON Checked By: JPH Model Name : FRAME E1 Envelope Member Section Forces (Continuedl RISA-3D Version 13.0.0 [C:\...\...\...\...\CALC\Frames\RISA3D\3D-WS-FRAME-E1-R19.r3d] Page P6�i o� 84 �Company : Joe P. Hill P.E. O Designer : CD Job Number : BURLINGTON Checked By: JPH Model Name . FRAME E1 Envelope Member Section Forces (Continuedl RISA-3D Version 13.0.0 [C:\...\...\...\...\CALC\Frames\RISA3D\3D-WS-FRAME-E1-R19.r3d] Page P6� o� 84 Company : Joe P. Hill P.E. � Designer : CD VirJl I Job Number : BURLINGTON Checked By: JPH Model Name : FRAME E1 _ EnveloAe Member Section Forces (Continued) RISA-3D Version 13.0.0 [C:\...\...\...\...\CALC\Frames\RISA3D\3D-WS-FRAME-E1-R19.r3d] Pag�� o°f 84 Company : Joe P. Hill P.E. ��� Designer : CD VU1 I Job Number : BURLINGTON Checked By: JPH Model Name : FRAME E1 EnveloAe Member Section Forces (Continued) RISA-3D Version 13.0.0 [C:\...\...\...\...\CALC\Frames\RISA3D\3D-WS-FRAME-E1-R19.r3d] Pag�� of 84 Company : Joe P. Hill P.E. � Designer : CD V�1 1 Job Number : BURLINGTON Checked By: JPH Model Name : FRAME E1 Envelope Member Section Forces (Continuedl RISA-3D Version 13.0.0 [C:\...\...\...\...\CALC\Frames\RISA3D\3D-WS-FRAME-E1-R19.r3dJ Pag�� 1� $4 Company : Joe P. Hili P.E. � Designer : CD \.Jlvt I Job Number : BURLINGTON Checked By: JPH � Model Name : FRAME E1 EnveloQe Member Section Forces (Continued) RISA-3D Version 13.0.0 [C:\...\...\...\...\CALC\Frames\RISA3D\3D-WS-FRAME-E1-R19.r3d] Pag��1 o�f 84 Company : Joe P. Hill P.E. � Designer : CD LJ��JI I Job Number : BURLINGTON Checked By: JPH Model Name : FRAME E1 Envelope Member Section Forces (Continuedl Envelope Joint Disalacements RISA-3D Version 13.0.0 [C:\...\...\...\...\CALC\Frames\RISA3D\3D-WS-FRAME-E1-R19.r3d] Pag�� o� 84 �8 �o ���fied IP£�'66b-63-3WtRi�-SM-O£\Q£`dSRi\sawe��\��d�\...�...�...�...\��� 0'0'E6 uois�a/�Q£-dSlb panu�;uo� s;uawa�e� s�p;wo� a o�anu3 l3 3WbR�� : aweN �apoW � Hdf ��8 pa�l�a4� NOlJNll21f18 � �a4�nN qoP O Q� : �au6isaa '3'd 11!H 'd ao� . �(uedwo� �g �.j� �e 6�d � sawe� uois�a d IP£ '66b-13-3W�d2i�-SM-Q£\4£tJSRi\ �\�lt/�\...\...\...\...\��l 0'0'£I. /� 4£-t/SI�I suo���a/,�aQ uo���aS �aqwayy a o�anu3 panu�;uo� s;uawa�e� s�p;u�o� a o�anu3 L3 3Wb21� : aweN �apoW � Hdf ��8 Pa�l�a4� NOl�Nll2if18 � �aqwnN qo� O Q� : �au6isaa '3'd II!H 'd ao� . �(uedwo� Company : Joe P. Hill P.E. ��� Designer : CD \.J��t I Job Number : BURUNGTON Checked.By: JPH Model Name : FRAME E1 Envelope Member Section Deflections (Continued) RISA-3D Version 13.0.0 [C:\...\...\...\...\CALC\Frames\RISA3D\3D-WS-FRAME-E1-R19.r3d] Pag�� of 84 �g � �e ��d � sawe� uois�a '"86 d �p£ '61b-63-3W`d21�-SM-QE\aEbSIN\ �\�ld�\...\...\...\...\��l 0'0'£l /� DE-dSl2J panu��uo� suo�;�a�,�ap uo���as �aqwa�jy a o�anu3 63 3Wtf21� : aweN �apoW � Hdf ��9 pa�I�a4� NOlJNll21f19 : �aqwnN 4of Q� : �au6isap � '3'd II!H 'd ao� . �tuedwo� �8 �° ��fi�d [p£�'66b-L3-3Wb2i�-SM-a£\a£`dSlb\sawe��\��d�\...�..1...�...\��] 0'0'E6 uois�an QE-dSlb panu�;uo� suo�;�a��aa uo�;�as aaqwaW a o�anu3 l3 3Wb2i� : aweN �apoW � Hdf ��8 pa�l�a4� NOl�Nll21f18 = �aqwnN qo� O Q� : �auBisaa '3'd II!H 'd ao� . �(uedwo� �� � sawe� uois�a �8'OZ �°d d IP£ '61b-63-3W`d2i�-SM-O£\QEdSl2�\ �\�ld�\...\...\...\...\��l 0'0'£l /� a£-dSl2� panu��uo� suo�;�aJ�ap uo���as aaqwayy a o�anu3 63 3Wb21� : aweN �apoW � Hdf ��9 pa�l�a4� NOl�Nllbfl8 : �aqwnN qof Q� : �au6isaa � '3'd II!H 'd aof • �uedwo� �8 }�Z ��6�d IPE�'612i-63-3WH��-SM-QE\QEdSIa\sa����\��tl�\...\...\...\...\��l 0'0'E 6 uois�an 0£-t/SRi panu��uo� suo���a��aQ uo���as aaqwaW a o�anu3 l3 3W`d2�� : aweN �apoW � Hdf ��8 Pa��ay� NOlJNllbfl8 � �aqwnN qo� O Q� : �au6isaa '3'd II!H 'd ao� . Ruedwo� �8 �z ��6�d IPE��6Lb-63-3WH2�.�-SM-aE\a£t/S121\sawe��\��d�\...\...\...\...\��l 0�0'£l uois�an Q£-dS121 panu�;uo� suo���a��aQ uo���as aaquiayy a o�anu3 l3 3Wb21� : aweN �apoW � Hdf ��9 Pa�l�a4� NOl�Nll21(18 � �aqwnN qo� Q� : �au6isaa � '3'd II!H 'd ao� . �(uedwo� Company : Joe P. Hill P.E. � Designer : CD V�1 1 Job Number : BURLINGTON Checked By: JPH Model Name : FRAME E1 EnveloQe Member Section Deflections (Continued) Material Takeoff RISA-3D Version 13.0.0 [C:\...\...\...\...\CALC\Frames\RISA3D\3D-WS-FRAME-E1-R19.r3d] Pag��1 �b�f 84 0 ANCHOR PLATE DESIGN FOR WIDE SPAN SHELVING: O.1C (12 b,� :A' N MAX. MAX. MAX. FRAME SHEAR UPLIFT COMP. (LBS.) (LBS.) (LBS.) E 137 635 450 .-,,, �,......,.. ANCHOR PLATE SHEAR CHECK: ✓ir� ur�ire i° �-.��t. r+�icKa eX18T. GONG. �LOOR -� �� ' � HOLE lTl'P 2 PLS) MATL: 12 GA. HRS; Fy = 30,000 psi; thickness = 0.1084" (MIN.) ALLOW. V= 0.4 * AREA * 30 KSI = 0.4"((1-3/8"-0.5")* 0.1084")''30 KSI = 1138 LBS ALLOW. V OF ANCHOR PL > MAX. UPLIFT LOADS OK UPLIFT/TENSION FORCE MATL: 12 GA. HRS; Fy = 30,000 psi; thickness = 0.1084" (MIN.) ; S= 0.194 in3 ALLOW M= 0.6 * 30 KSI " 0.194 in3 = 3492 LBS-IN ALLOW UPLIFT = ALLOW M* 2/ 1" = 6984 LBS ALLOW UPLIFT > MAX. UPLIFT LOAD OK CHECK OF THE MAXIMUM DOWNWARD VERTICAL FORCE BASED ON THE BEARING STRESS IN CONCRERTE: F'p = 0.35 fc = 0.35 x 3000 = 1050 psi Aeff = 3.75 x 2.25 = 8.44 in^2 ALLOW. P= F'p x Aeff = 8862 LB ALLOW. P> MAX. COMPRESSION AT THE BASE OF THE COLUMN OK WIDE SPAN UPRITE SHEAR CHECK: MATL: 14 GA. A653; Fy = 30,000 psi; thickness = 0.072" (MIN.) ALLOW. V= 0.4 * AREA " 30 KSI = 0.4 "(.372) * 30 KSI = 4464 LBS ALLOW. V OF UPRITE > MAX. UPLIFT LOADS OK CARRIAGE BOLT BEARING CHECK: CONNECTION SCREW SHEAR CHECK: ASTM A449 0 5/16"-18"x22" BOLT; Fu=65 KSI (14ga MATL) ASTM A449 0 5/16"-18"x22" BOLT; Fnv=47 KSI ALLOW. V= 3.43K / 2.5 = 1372 LBS (TABLE IV-7c, AISI ALLOW. V= 3.06K / 2.4 = 1500 LBS MANUAL 2002) (TABLE IV-6, AISI MANUAL 2002) _> ALLOW. V(SEISMIC) = 1.0 (ALLOW. V) = 1372 LBS => ALLOW. V(SEISMIC) = 1.0(ALLOW. V) = 1500 LBS ALLOW. V(SEISMIC) > MAX. UPLIFT LOADS OK ALLOW. V(SEISMIC) > MAX. UPLIFT LOADS OK �og: 16279 DATE: 07/07/16 JOE P. HILL, P.E. BY: Cp CHD: �pH CONSULTING STRUCTURAL ENGINEERING 1801 N. HAMPTON RD., SUITE 440 DESOTO, TX 75115-2399 972-283-5111 E-Mail:Joe@jphpe.com Page 83 of 84 � • � SLAB PUNCH SHEAR FOR FRAMES E1: 4" THICK CONCRETE SLAB fc' =2500 PSI MIN. (NO INSPECTION) ALLOWABLE SOIL BEARING PRESSURE = 1000 PSF (DL+LL) CONTROLS --> P(MAX) = 2000 LBS BEARING PLATE 3 3/4" x 2 1/4" TYP. (AREA = 8.44 SQ. IN.) FOR TWO WAY DIAGONAL TENSION ACTION: SHEAR V = 1.7xPnet (EFFECTIVE AREA) V = [3400/2.25] x [2.25 - 0.3364] = 2891.71 POUNDS AREA OF FOOTING AREA REQ'D = 2000/1000 = 2.0 SQ. FT. USE 1'-6" x 1'-6" (AREA = 2.25 SQ. FT.) ACTUAL BRG PRESSURE = 2000/2.25 = 888.89 PSF FACTOR OF SAFETY = 1000/888.89 = 1.12 OK v = 2891.71/[((7.75"x2)+(6.25"x2))x4"] = 25.82 PSI Vallow = 0.85x2[fc']^2= 85.0 PSI Vallow > v OK N "� LENGTH =(7.75" x 2) +(6.25" x 2) = 28" AREA=Lxt = 28" x 4" = 112 SQ. IN. v= 3400 LBS / 112 SQ. IN. = 30.36 PSI Vallow = 0.85x2[fc']^i = 85.0 PSI Vallow > v OK .1oB: � 6279 DATE: 07/07/16 JOE P. HILL, P.E. BY: Cp CHp: �pH CONSULTING STRUCTURAL ENGINEERING 1801 N. HAMPTON RD., SUITE 440 DESOTO, TX 75115-2399 972-283-5111 E-Mail:Joe@jphpe.com Pa e 84 of 84 O APPENDIX A TYPICAL LOZIER TECHNICAL SPECIFICATIONS ,IOB: � 6279 DATE: 07/07/16 JOE P. HILL, P.E. BY: Cp CHD: �pH CONSULTING STRUCTURAL ENGINEERING 1801 N. HAMPTON RD., SUITE 440 DESOTO, TX 75115-2399 972-283-5111 E-Mail:Joe@jphpe.com A1 LOZIER WIRE BACK ASSEMBLIES USED ON SALES AREA WALLS HOME AND BABY DEPARTMENTS A2 � � � • ' Lozier shelves are designed to satisfy a wide range of Brackets are an integral part of the shelf providing rugge merchandising needs and load requirements. All construction and fast installation. Shelves are vertically shelves feature precision formed tag moldings that adjustable in 1" interoals and can be sloped at angles accept 1.235" high tags. Shelves and decks have shown below. Recommended load capacities shown are double rows of perForations 1" on center at fFont and based on evenly distributed static load. All shelves and rear edges for vertical dividers, binning, and product decks are finished with a durable wear resistant finish. retainers. Capacities shown are reduced by 30% when front half only is loaded. LOAD CAPACITI'E� AND ANGULAR ADJUSTMENTS MAX. EVENLY DISTRIBUTED STATIC LOAD CAPACITY (in Ibs.) 17° 30° 15° BRACKET PROFlLE SHELF SHELF DOWN• DOWN- UP- S7YLE DEPTH FLAT SLOPE SLOPE SLOPE _� _ . _.—_ l.�-�� - . —; � TL 5tyle & 7` 300 300 - - '�,o _ - �- --- ` _. _ ��� � SiYLE S STYLE � y S Style 10'ihru 19" 500 250 G�--��" — , :1-�� -, .� � � �--�- _'—�•:`, �� !— �'��—' " TL Style 8 20' 8� 25" 500 250 - - �- �--'-�J 7L SME S STYLE S Style 28" & 31' 400 Z00 r-..,`— ���-,r;� DLStyle 7" 300 300 125 Z00 �y � .�.----.--� 10"thru19' S00 250 125 300 i�__--.� �—'—� � �rJ� �� _�.�� ��' DL Style 22" & 25" 5�0 250 125 - ci _.r- . 28" 8 31° 400 200 100 - t,° r-_ �-- - _ ^ �— • .�-�'',L �- HL Style 16" thru 19' 60D 250 125 - c=� ., _" ' 1� r-��..�- � • _ a� _ ? � ��"` � HL Style 22" 700 - - i_-� . _ __.��- ,�_ L--- ��'�_ ' •° j i--ri" ---_,� �" �. G�� f�f --f � ML Style 28" &^31" 60D - - - 1 . ��"' • �` _ � ' � . Std. Decks 13" thru 19" 600 22"thru31" 800 _ ` Heavy Duty 19" 900 �_; �° _ _ Dadcs 22" thru 31" 1Z00 {same profileas Add load easer brackeis (pg. 206) for Std. Decks) 500 Ibs. addiGonal deck capaGty. P.O. BOX i9999 • OMAHA, NEBRASKA 68119-0999 •(800) 228-9882 Specifications subject to change wifhout notice. A3 � ������ � 1999 Lozier Corporation ig and �ts contents are the excluswe and confidentwl property of Lozier Gorporation and its �mpanics. The draaving is prrn�ded only for the purposes mtended and shall at �II times ba kept I by the customer or supplier, who shall not, vnthout the prvor urt•itten conserit of Loner, diclose, �eminate, in whole or m part, this dravnng, �ts coriterits, or concepts, and shail promptly retum g upon request without retammg any copies thereof. STIFFENER 75 82 7/8 84 ! 35 I 42 7/G I 44 69 76 7/8 78 I 29 I 36 7/8 I 38 63 70 7/B 72 I 23 I30 7/8 I 32 57 6Q 7/$ 66 ! 17 I 24 7I8 I 26 5! 58 7/8 60 I I I I I 8 7/8 I 20 45 52 7/8 54 i 05 I I 2 7/8 I I 4 39 46 7/8 4b 99 I06 7!8 I 08 33 40 7/b 42 93 I 00 7/8 I 02 27 34 7/8 36 87 94 7/8 96 2! 28 7/8 30 8I 88 7/8 90 I 5 22 7/8 24 N:.a.OF A NOM NO.OF A NOM St0T5 SLO75 TOP Cr��P �- A SECTION B-6 LEVELING LEG ASSEMBLY NOT SHOWN STIFPFNER � --�----�-- � -{�-- - - --�---�-- SECTION GC LEVELIN6 LEG A55EMBLY NOT 5t10WN B e iF i4 f i F � O - O%� - _ � O O "— UP�ilTE LEVELER LEG ASSLY. FACE CHi.NNEL SIOf CYIANNEL I / C � � � � � � � � � � � � � � � � = A 51DF CHANNFL SEGTION A-A I /B MAK F,h:EGt1ANNEL -- ---- I!8 * DETAI L OF FACE SHOWING WELD 4CE GHiJJNEL (�TE61 I ) FLU5t1 TO 316a �:nX fXTENCED OR il32 MAX RECESSED (Dc�EPT TOP I'� �2000 LOZIER CORP. : �.�1,.=�.�'� UPRITE DETAILS 6336 PERSHING DR. OMAFiA, NE 681 I O ' SIiEET � OF 2 I -800-228-9882 This drawing and its contents are the cxclusive and conhder�tiai properLy of Lozier Gorporat�on and its afhiiated compames. The drav,nng is prov�ded only for the purposes mtended and 5hall at �II times be kept confidential by the customer or suppiier, who shal{ not, Hnthout the pnor wrytten conserrt of tna�r, diclose, use or d�ssemmate, in whofe or in part, this drawing, its eoritents, or concepts, and shall promptly retum the draMnng upon request tivithout retammg any copies thercof. 18 GA. SIDE CHANNEL MATERIAL SPECIFICATION COLD ROLLED HIGH STRENGTH, LOW ALLOY (tiSlA) GRADE 45 GLA55 II STEEL. MATERIAL TO MEET ASTTvI SPECIFICATION A607. LIMffED TO 57000 P51 MAX YIELD, 2295 MIN ELONGATION IXCEFf 24%a NATIONAL AND US STEEL. LIMITED TO 55000 P51 MIN TEN5ILE ORDER TtiIGKNESS: .043 MINIMUM. 5/ I 6 TYP -.375 � I I '991 2 I 7/32 ! .761 y- R3/32 .298 —RI/16 MAXTYP I 9/32±0 1:.505 1.643 I .935 R9/64 ' TO SNARP CORWER TO START OF RADIUS DETAIL A �4� FACE CHANNEL MATERIAL SPECIFICATION VENDOR SPEGIPIGATIONS: I I/4 X 3/8 X IENGTFi, ASTM f 044 SPECIAL t107 ROLLED STEEL Wfftt .6096 TO .90% MAGANESE (GALUAIE� OR ASTM A572-60 HOT ROLLED STEEL (COURTICE) YIELD: 60,000 P51 MINIMUM +.031 _� r375 �3• s I/2• I +.020 I .275 -.O I O .187 MAXIMUM OYERALL ;1.237 .730 y�p�ry � MINiMlJM PIAT , C�2000 LOZI�R CORP. ��i.�.�s� 6336 PER5111NG DR. OMAf1A, NE 681 I O �J -800-228-9882 S110WING 5LOT5 2 25/32 I 5/8 I/2 �JPRlTE DETAILS ShEET 2 OF '2� A5 0 � �dr� w� � DAddd MNH� al�� � O W c� a Vl z 0 � H � U � H w^ T1�+��1 V1 z W � � U � a l3NNt/H� 31RIdf1 '1331S 3uu NOI1dW�530 Noisv�a n3a O�d -+ p1 0- lf0'+ NOHd � �� O ` � O 3 `� o t r o Z z=wz� � �' � � m N �ac�3 m Z``i o � o m N w w �F �a� �' e€ � � � � Z � � p � � \N� � p a N � m�p� • m �J vpq1 W � � � .�. � O� Y m t� tn ad z J m Z �j � ��� � � j�� �� Q� � W � LL !7) �� � W �OJ On � Ii, o � O Z � c�i� � �ayw �Oi �3 � � � � �� Z��WW ZN � 7 7 w O i li N U�U �Q �� U m--� O fV M � � �D I� W Of � 00 +n��3 N N T N }�- I zro M��� n m - � N M O \ � 'F1 N � m m mo_ 0 �* � a � �� � � �z Z o � � �} N q � _. jW O � Z �� W � Z = K � U� N 0� O � � U : LLL£9 � Z-3 � d0 1 3�Id ^mONlIM � L IIGXM Y6! �qliflJ 7M1 !0 7if1 iqi 31LL YO! q OM1 'i00 nQ01 3LL �o wu�ow �mrrq�a �ru c� a�ewmo au IO{O�C 111i �r. 1�1 1 F L�1 t i i1/�OM! 1�/1 � Oill Q A/1 M ��OY ��� p e�r s n�e U33.73i 6aM WN�OI NOLLWQRIO� N3ROl BBBIm �� O "° �°'°°'"° 8�/90 'A1f10 1J�d3H `l3NN'dH� 3�b.� .' �"� � o "' ` ° '°""" �. � �.� :�uu „�, o � = � ;,' � � awrua Notldla�s3a NOISIA3a /�a O�d 01r �"0°` �"�0 �, a3izo� ss <<z lo aasv�3a v �a�ac �,�� �,� 310HA3H Q�V `05094 8�d tf3d �9B1' H M M3N PI1B Ol S3V�IlON dtl5 U3�Q�f B 15194 � a �"a+"' "°"°"°'s'° �"+ M31� YY18 W02l� 53H�lON d`dS 03/�OW321 � bOL94 ��� ��'� �'� '�"'� �" so uneow aniarpx� 3w s� oM�wa a�u WIQ 05L'Z SVM WId BLL'Z 0 199SS ,� �� m 0 � J Z ZZ � _ �tpn0� N Q F_ �Jb� � U � 4. Nr.d]w {I � �-' W � � W � z W �� 3 w o m ? W ���� � J I� � � U � � . � n � W � � � ONO :°na`r O � so�- :�xR v a �'HJ O�UvUl4i t- W �OW�Q a 0D � z `` � ��` o a z�ao�000zZw U°o��m •���ov=� � �p��` ��`�'wWU o.-����3�i�yz~Wm �Ip�NQ 6Wl'"� IL �� a�Zoo ���'onzo���w~y X���=�W��� �~ ����a�c' 23�n^d� p � N 17 sF tn W f� Z �_� � ��i o=� o�N ao� ��z a r3� �a� �Wz� K Q d�U O � � Zm0 _ =O� f � �w� z� ��a � U � � b o m � rn W� � � � � � In F � � W j3 � UC � 4� m Zo W � J ; Za a � � � �o +� N a � N ,T u� N �o� �f1 = � � � T3•� ~ W oN�- ¢ �a� ��g ��� +i g �g� � g�a � U O Kf M M M M M 1� M M O O � M � � Z � , � � � � Vf (!! Vl N Vl VI i%f Vl �/1 a � n n��� a a n r�n c��t � O 2 \ \ \ \ \ \ \ \ \ \ n n n n n n � n n n Q h O t�0 ��[1 � V�' � M c�Y N o� t�0 t�D N� t M M N N� V O� Z �� M M M M���� Wq tD tD tD tD tD t0 F- O O Qi 00 ! tO � d' M N �I � I 1 I I I I I 1 0 O O O O O O O O O O Z M M � M I'1 c��o m� m m�� � m� aa V1 fn (/1 N fn 41 4! fA f/1 fn a� M N N � o o�� z, \ � � \ \ \ \ \ \ \ n n n n n n n n i,, �,, Q d M M N m N O O O�1 m M N N r O� o� O�f OMi En0 aD U O Z N J n n n n n n n n n� � a i nr� nn � n n � n n n�z � uf �o cMo m � m � � � � �Y U F O A7 Q � 3liadn �iea3ais '"'"'""'" `""'w" ' Q.. �m m�a�o u.no..,R.rxv ,�u �m�a iwu mru� io� �+w -�--- �t/w nQvo � xne�m �m �ox�� .w/�: mex p m� • cr rt� '4lON7lM � L 110H: i0f r'i1101pq �Il �j' �yp/// unw� p 0� • mr eMm d' Z o so aen 3ws su xor o an •mm �¢m au io uu3aor� wmon au a auneo au --- r�' wu�+a aru�n o�vmYv�mw a. �f N N N � � [D z w � i � ¢ �I �am No a a o a�3 c! „�� � �- d� � I` ^ ' ^ �p� �t��if ��I � � ��� a� � L M W � Z � O= � 4 � y Z � r •N ^ N � � � � � L� O O� �� K = W ^ m Q � W � N O � t�. X Z tp � \ K � w � � �W U N Nv W ���'''```--- 00 N pl *Z � W 1 �I ' �yWj ap la. W O� N � Z — O 3NRiSrB� _ �j �O�N � �d � ��� � M � N � �v � W t0 � M � � pO I d' � U �a � � � � � _ � O m � �" � m V W � W L _ N � o� a r� � a� _ o � � � � �� a r! a ga �? �ga `y °>, °� a �� oo m �i � 4 m �� N � ^ � o � o m V � � yZ C 0 7 C � ' C C -� � L V ' 4 Q � G �— - � � � n �� � � n � � n w NW�N N N Z go M 04 � +1 K� U ---� � M O� Z : ���ri 1-� N W ..�.— � M � �� � � o � +b � z o "� � w � I � o g � I �W� � x � � � � � a�z WsZ a�� �� v, n � 2 � 5 � 0 � N 1 W N Z ` � • � � 9l/90 `lllfla �lAtl3H `311adf1 �';, „, o ��� � .�;:�„� �31111 �¢rra�e se�tNn cnMvrrioi M ioahoe�oo mm ua � 'G.IGICLIi N 11 IIOIW r0! IMOW17 11LL �D �ul llDf 71LL IIQI A WM 'JIW YfQdl 31LL !0 lJiO/WN iNCrtA70 71LL CI lNMran nMl 0 O � Z � M � z w � ? �mz Q o � �� ��� � �\�� 'HU Z��w I � W �� �� � J �� � WQ ���a --� zW �� 9� �� � � �� � � � � � � 30 7 �� � � �„ � � �Z o��n r\ � �m f 1 W�o � �° �mN �� DGDW � om * �VIJ ~O Z\� � ��li �-7Z �-WQ W 2 � 0 0 OWZ ��w �� N II Wm= �? W W _----0 II II �FU �o �j� m� 0�p Y� a� ii ii '�`az'a' w m� � M �3 '� 'N O W� �� ii ii � � k-'' O O - --c� � - o � � � OZ Z�^ O mp- A u Z�Z � N W W 1�.0 u p �N v H �OWO� �Vl I v : a �o �Z �_ �� � N � m � CV O � 2 p . � � f�/f�Vl IaJ W W � � 3 v � y Z � 2 O {{�� N �� � � N J 4 a e z O � W O w a �_^ �zs �o� c� • ¢ �z� 0 � z�� � ��r \� Z � 2 '�'��jW SMO� N � v � � � Z � W��� mdo� �i,zo� ���d� -� �Vza �og,� w I N�� `il��Li 1O � a �4� �O Z W m N � \ W '- W �OO= N Nv O Q ~ N 2 W z ��� O W �N V O u N � az Z1Oo�d" O� IU U � axao � � �w Z K � �h � U 1 • INSTALLATION INSTRUCTIONS WIREGRID BACK ASSEMBLIES (ONE PIECE GRID, UP TO U96) Step 1: Set up shelving sections following display shelving installation instructions 01-13 using either BR_ OR BRHD_ bottom rails. See retainer types on page 2. TOP RAIL (R_l� UPPER WIRE GRID RETAIN ER (RUS_) EXTENSION WIRE GRID RETAINER RAIL (RES_) STANDARD DU' BOTTOM RAIL �BR_) HEAVY DUTY BOTTOM RAIL (BRHD_) ����� ���� „��EMBLY ����� OMAHAPNEBRASKA 68110 ECO# OMPCOA6368 07/3�1�/1�5 02015 LOZIER CORPORATION (800) 228-9882 PAGE 1 OF 6 INSTALLATION INSTRUCTIONS WIREGRID BACK ASSEMBLIES Step 2: A) Install the lower horizontal wire grid retainer (RES_) on the bottom rail. B) Install the wire grid back on top of the lower horizontal wire grid retainer. The wire grid back should locate in the channel of the lower horizontal wire grid retainer. NOTE: See Figure 3 for wire grid back orientation. C) On each side of the wire grid back, slide the vertical wire grid retainers (RES_) down between the uprite and the wire grid back. The wire grid back should locate in the channel of the vertical wire grid retainer. If the wire grid back is taller than a nom 48, the vertical wire grid retainer will be a two piece retainer (RES_ and an RUS_). NOTE: If using triple track wire grid retainers (RET ) with a centered hardboard back, slide the hardboard back down the center channel of the retainers prior to installing the upper vertical wire grid retainers (RUT_). D) Install the upper horizontal wire grid retainer (RES_) on top of the wire grid back. The wire grid back should locate in the channel of the upper horizontal wire grid retainer. E) For systems with two backs vertically (taller than U96) go to page 3. Systems U96 and shorter, go to step F). F) Install the top rail (R_�. RETAINER TYPES: GRID WG) RETAINER RES BO�TTOM RAIL RETAINER RET RETAINER RED SINGLE TRACK DOUBLE TRACK TRIPLE TRACK ����� OMAHAPNEBRASKA 68 10 ECO# OMPCOA6368 07/�1�5 (800) 228-9882 PAGE 2 OF 6 OO 2015 LOZIER CORPORATION INSTALLATION INSTRUCTIONS WIREGRID BACK ASSEMBLIES (MULTI-PIECE GRID, TALLER THAN U96) Step 3: A) Instati the splicer rail (R_S). B) Install the lower horizontal wire grid retainer (RES_) on the splicer rail. C) Install the wire grid back on top of the lower horizontal wire grid retainer. The wire grid back should locate in the channel of the lower horizontal wire grid retainer. NOTE: See Figure 3 for wire grid back orientation. D) On each side of the wire grid back, slide the vertical wire grid retainers (RES_) down between the uprite and the wire grid back. The wire grid back should locate in the channel of the vertical wire grid retainer. If the wire grid back is taller than a nom 48, the vertical wire grid retainer will be a two piece retainer (RES_ and an RUS_). E) Install the upper horizontal wire grid retainer on top of the wire grid back. The wire grid back should locate in the channel of the upper horizontal wire grid retainer. F) Install the top rail (R_�. TOP RAIL (R T) SPLICER RAIL (R_S) UPPER WIRE GRID ' RETAINER (RUS_) EXTENSION WIF GRID RETAINER (RES_) STANDARD DU BOTTOM RAIL (BR_) �� HEAVY DUTY BOTTOM RAI (BRHD_) � � � � ��--� rl\7VRC L �� WIRE GRID ASSEMBLY WITH SPLICER ����� OMAHAPNEBRASKA 68 10 ECO# OMPCOA6 68 07/3�1/1�5 (800) 228-9882 PAGE 3 OF 6 02015 LOZIER CORPORATION INSTALLATION INSTRUCTIONS � TOP BOT+T'OM � ��f TOP BOTTOM t TOP WIREGRID BACK ASSEMBLIES + BO + OM RBE_MG i � 3 REF ---�- RBE_SG RBE_WG FIGURE 3 WIRE GRID BACK ORIENTATION �� 4 1/2 REF -�---- - L 1/2 { REF 1/2 .EF � � 3 1/2 REF �� ����� OMAHAPNEBRASKA 68 10 ECO# OMPCOA6368 07/3�1/1�5 (800) 228-9882 PAGE 4 OF 6 OO 2015 LOZIER CORPORATION INSTALLATION INSTRUCTIONS WIREGRID BACK ASSEMBLIES WIRE GRID BACKS AND REfAINERS LOWER WIRE UPPER WIRE LOWER WIRE UPPER WIRE LOWER UPPER UPPER UPPER UPRITE GRID BACK GRID BACK VERTICAL VERTICAL VERTICAL VERTICAL HEIGHT GRID BACK GRID BACK ACTUAL SIZE ACTUAL SIZE RETAINER RETAINER RETAINER RETAINER NOM SIZE NOM SIZE ��g�� DIM "C" DIM NOM SIZE NOM SIZE NOM SIZE NOM SIZE 36 RBE_30_ N/A 29 N/A RE_30 N/A N/A N/A 42 RBE_36_ N/A 35 N/A RE_36 N/A N/A N/A 48 RBE_42_ N/A 41 N/A RE_42 N/A N/A N/A 54 RBE_48_ N/A 47 N/A RE_48 N/A N/A N/A 60 RBE_54_ N/A 53 N/A RE_48 RU_06 N/A N/A 66 RBE_60_ N/A 59 N/A RE_48 RU_12 N/A N/A 72 RBE_66_ N/A 65 N/A RE_48 RU_18 N/A N/A 78 RBE_72_ N/A 71 N/A RE_48 RU_24 N/A N/A 84 RBE_78_ N/A 77 N/A RE_48 RU_30 N/A N/A 90 RBE_84_ N/A 83 N/A RE_48 RU_36 N/A N/A 96 RBE_90_ N/A 89 N/A RE_48 RU_42 N/A N/A 102 RBE_48_ RBE_48_ 47 47 RE_48 N/A RE_48 N/A 108 RBE_48_ RBE_54_ 47 53 RE_48 N/A RE_48 RU_06 114 RBE_48_ RBE_60_ 47 59 RE_48 N/A RE_48 RU_12 120 RBE_48_ RBE_66_ 47 65 RE_48 N/A RE_48 RU_18 126 RBE_48_ RBE_72_ 47 71 RE_48 N/A RE_48 RU_24 132 RBE_48_ RBE_78_ 47 77 RE_48 N/A RE_48 RU_30 138 RBE_48_ RBE_84_ 47 83 RE_48 N/A RE_48 RU_36 144 RBE_48_ RBE_90_ 47 89 RE_48 N/A RE_48 RU_42 Notes: 1) Wire backs can be 3x3 wire grid (RBE_WG), slot grid (RBE_SG), multi grid (RBE_MG) or louver grid (RBE_LG). 2) The bottom rail must always be a BR_ or BRHD_. (See order for actual parts) 3) The horizontal retainers will be RESJ RED_ or RET , where _ is the nominal width of the system. 4) The upper and lower horizontal retainers are identical. 5) Wire backs can be replaced with hardboard backs (RBE*P, RBE*M or RBE*ME). 6) Units taller than 96H require a splicer rail. 02015 LOZIER CORPORATION 6336 PERSHING DRIVE 84691 fj�V� �} OMAHA, NEBRASKA 68110 ECO# OMPCOA-368 07/31/15 (800) 228-9882 PAGE 5 OF 6 INSTALLATION INSTRUCTIONS WIREGRID BACK ASSEMBLIES WIRE GRID BACK MERCHANDISING LOAD MATRIX ________ NOM 30" WIDE AND NOM 30" WIDE AND NOM 3' AND 4' WIDE NOM 3' AND 4' WIDE LESS LESS U96 OR SHORTER TALLER THAN U96 U96 OR SHORTER TALLER THAN U96 (WIRE OR (WIRE OR (WIRE OR (WIRE OR SLOTWALL BACKS) SLOTWALL BACKS) SLOTWALL BACKS) SLOTWALL BACKS) ___ _ LOAD RATING PER LOAD RATING PER LOAD RATING PER LOAD RATING PER SECTION SECTION SECTION SECTION (SINGLE PIECE (MULTI PIECE BACK (SINGLE PIECE (MULTI PIECE WITH BACK WITHOUT A WITH SPLICER BACK WITHOUT A SPLICER RAILS SPLICER RAIL (R_S)) RAILS (R_S)) SPLICER RAIL (R_S)) (R_S)) BACK TYPE RAIL TYPE PER SIDE PER PER SIDE PER PER SIDE PER PER SIDE PER SECTION SECTION SECTION SECTION 3 x 3 Wire Grid BR_ 150 Ibs 150 Ibs 150 Ibs 150 Ibs 3 x 3 Wire Grid BRH_ 350 Ibs 350 Ibs 350 Ibs 350 Ibs Slot Grid BR_ 150 Ibs 150 Ibs 150 Ibs 150 Ibs Slot Grid BRH_ 350 Ibs 350 Ibs 350 Ibs 350 Ibs Multi Grid BR_ 140 Ibs * 130 Ibs * 120 Ibs * 100 Ibs * Multi Grid BRH 340 Ibs * 330 Ibs * 300 Ibs * 270 Ibs * Louver Grid BR_ 120 Ibs * 90 Ibs * Not Recommended Not Recommended Louver Grid BRH 320 Ibs * 290 Ibs * 250 Ibs * 200 Ibs * Notes: 1) Items marked with * are derated for the weight of the back. 2) The above load ratings assume that the bottom rail tab is bent per II 01-13 for single sided sections. 3) For backs nom 60" wide, reduce the above loads for a nom 3 and 4' wide by 20% (multiply above loads by 0.80). 4) For shorter systems, when the wire grid or slotwall back panel is shorter than nom 90" tall or nom 144 tall, you can calculate a higher merchandising load by adjusting for the difference in the weight of the back panels. Note: Do not exceed 150 Ibs per side or 300 Ibs total per section when using a standard bottom rail. Includes the back weight and the merchandising weight. Note: Do not exceed 350 Ibs per side or 700 Ibs total per section when using a HD bottom rail. Includes the back weight and the merchandising weight. ozs�� OO 2015 LOZIER CORPORATION 6336 PERSHING DRIVE 84691 fj�V� � OMAHA, NEBRASKA 68110 ECO# OMPCOA-368 07/31/15 (800) 228-9882 PAGE 6 OF 6 NSTA��ATION INSTRUCTIONS WALL MOUNT BRACKET (DC2191) Anchoring of all Wall Sections is recommended for limiting deflection under loaded conditions. Additional unbalanced load capacity may be available if the Wall Sections are anchored to a suitable building wall or other structure to prevent collapse of the shelving. Wall Sections must be assembled per Display Shelving Installation Instructions 01-13. The purchaser of the fixture is responsible for determining the suitability of any specific wall or structure to which shelving is anchored, for the selection of and/or proper installation of the anchoring fasteners, hardware and materials, and for the workmanship of those performing anchoring. These guidelines are meant to illustrate typical types of anchoring and do not constitute any endorsement by Lozier of any specific anchoring application. Each application will vary due to the building, structure and materials used for anchoring, and professional advice should be sought for each anchored installation. Anchoring situations other than those illustrated may be encountered. As a guideline, each anchoring location shown must provide a minimum of 450 pounds of pull—out resistance and be located as shown in these illustrations. Extreme care must be taken to insure that the building wall or other structure is solid and suitable for anchoring and will support the load being anchored to it. CAUTION: DO NOT USE PLASTIC OR FIBER ANCHORS, CONCRETE NAILS, OR REGULAR NAILS. CAUTION: DO NOT OVERTIGHTEN FASTENERS. OVERTIGHTENING CAN CAUSE MATERIAL DAMAGE OR THREAD DAMAGE, CAN WEAKEN THE CONNECTION, AND COULD CAUSE THE PRODUCT TO COLLASPE CAUSING BODILY INJURY OR PROPERTY DAMAGE. z 6" MAX � � 2 X 4 BLOCKING � (SEE PAGE 3) j • x 6" MAX � 1 � 2 X 4 BLOCKING � (SEE PAGE 3) j w 2 X 4 SPACER v w ATTACHED TO WALL a AT 48" O.C. MIN. � w z � o 12" Max � SINGLE LEVEL BLOCKING ��U�� OMAHA, NEBRAS A D 681 10 PCR866619 � 01=2�611 �Zo>> LOZIER CORPORATION (800) 228-9882 PAGE 1 OF 3 INSTA�L�ATION INSTRUCTIONS WALL MOUNT BRACKET (DC2191) CENTER UPRITES— Slide Wall Mount Bracket over Uprite Side Channel. (See FIGURE 2). Attach Wall Mount Bracket to approriate wall or 2 x 4 Blocking. END UPRITES— Place Wall Mount Bracket over the lip of the Uprite side channel. (See FIGURE 3). Attach Wall Mount Bracket to appropriate wall or 2 x 4 Blocking. FIGURE 2 CENTER UPRITES FIGURE 3 END UPRITES NOTE: All fasteners shown are minimum diameter and length for applications illustrated. 2 X 4 CONTINUOUS BLOCKING (SEE PAGE 3) u�t ��� � i u x 1 1/2" WOOD SCREWS ALL TYPES OF 1PALL �PITH CONTINUOUS BLOCHING u�t ��� CONCRETE WEDGE ANCHORS DIRECTLY TO CONCRETE 1PALL ����� OMA A6 NEBRAS A D 6I81 10 PCR866619 � 01=2�71 1 �2011 LOZIER CORPORATION �800� ZZS-98HZ PAGE 2 OF 3 INSTA��ATION INSTRUCTIONS WALL MOUNT BRACKET (DC2191) NOTE: All fasteners shown are minimum diameter and length for applications illustrated. ,� ATTACH AS NEAR AS POSSIBLE TO UPRITE �, �" X 4" LAG SCREW )UGH UPRITE INTO BLOCK 2 X 4 CONTINUOUS BLOCKING BEHIND UPRITES CONCRETE �POOD STUD �PALL X 4 CUT BOARD :TWEEN UPRITES FOR WOOD & METAL FRAMED WALL; ATTACH TO EACH STUD 2 X 4 BLOCKING BETWEEN UPRITES ATTACHING BLOCHING TO WALL ?X4 BLOCKING WEDGE ANCHOR 2X4 BLOCKING CONC. i/16" X 4" LAG SCREW �T EACH STUD 2X4 BLOCKING �1 /4" SELF—TAPPING MASONRY SCREW. EMBEDMENT INTO SOLID MATERIAL MASONRY (CONCRETE BLOCK, BRICK, ETC.) 2X4 BLOCKING 2) #8 X 2 5/8" SELF— )RILLING DRYWALL SCREWS �T EACH STUD METAL STUD �PALL (14 ga. min. ) ����� OM HA6 NEBRAS A D 681 10 PCR866619 EV 01=2�811 �zo>> LOZIER CORPORATION (800) 228-9882 PAGE 3 OF 3 NSTA��ATION I NSTRUCTIONS WALL MOUNT BRACKET (CD6921) Anchoring of all Wall Sections is recommended for limiting deflection under loaded conditions. Additional unbalanced load capacity may be available if the Wall Sections are anchored to a suitable building wall or other structure to prevent collapse of the shelving. Wall Sections must be assembled per Display Shelving Installation Instructions 01-13. The purchaser of the fixture is responsible for determining the suitability of any specific wall or structure to which shelving is anchored, for the selection of and/or proper installation of the anchoring fasteners, hardware and materials, and for the workmanship of those performing anchoring. These guidelines are meant to illustrate typical types of anchoring and do not constitute any endorsement by Lozier of any specific anchoring application. Each application will vary due to the building, structure and materials used for anchoring, and professional advice should be sought for each anchored installation. Anchoring situations other than those illustrated may be encountered. As a guideline, each anchoring location shown must provide a minimum of 450 pounds of pull—out resistance and be located as shown in these illustrations. Extreme care must be taken to insure that the building wall or other structure is solid and suitable for anchoring and will support the load being anchored to it. CAUTION: DO NOT USE PLASTIC OR FIBER ANCHORS, CONCRETE NAILS, OR REGULAR NAILS. CAUTION: DO NOT OVERTIGHTEN FASTENERS. OVERTIGHTENING CAN CAUSE MATERIAL DAMAGE OR THREAD DAMAGE, CAN WEAI�N THE CONNECTION, AND COULD CAUSE THE PRODUCT TO COLLASPE CAUSING BODILY INJURY OR PROPERTY DAMAGE. 6" MAX � I' 2 X 4 BLOCKING (SEE PAGE 3) 2 X 4 SPACER ATTACHED TO WALL AT 48" O.C. MIN. � 12" Max � SINGLE LEVEL BLOCHING ����� OMAHA, NEBRASKA D 681 10 OMPCOA-613 7-6=�1� �2016 LOZIER CORPORATION �800� 2Z$-9HS2 PAGE 1 OF 3 INSTA��ATION INSTRUCTIONS WALL MOUNT BRACKET (CD6921) Rotate Wall Mount Bracket into Uprite Face Channel. (See FIGURE 2). Attach Wall Mount Bracket to 2 x 4 Blocking. WALL MOUNT BRACKET 2 X 4 CONTINUOUS BLOCKING (SEE PAGE 3) FIGURE 2 NOTE: All fasteners shown are minimum diameter and length for applications illustrated. u�t �z� � i u n 1 1/2" WOOD SCREWS ALL TYPES OF 1PALL WITH CONTINUOUS BLOCHING ����� OMA A6 NEBRAS A D 681 10 OMPCOA-613V 06=23� 16 02016 LOZIER CORPORATION �8��� 228-9$$2 PAGE 2 OF 3 INSTA��ATION INSTRUCTIONS WALL MOUNT BRACKET (CD6921) NOTE: All fasteners shown are minimum diameter and length for applications illustrated. CONCRETE �POOD STUD WALL ATTACHING BLOCHING TO �PALL !X4 BLOCKING WEDGE ANCHOR 2X4 BLOCKING CONC. i/16" X 4" LAG SCREW �T EACH STUD 2X4 BLOCKING �1 /4" SELF—TAPPING MASONRY SCREW. EMBEDMENT INTO SOLID MATERIAL MASONRY (CONCRETE BLOCK, BRICK, ETC.) 2X4 BLOCKING 2) #8 X 2 5/8" SELF— )RILLING DRYWALL SCREWS �T EACH STUD METAL STUD WALL (14 ga. min. ) ����� OMA A6 NEBRAS A D6I8110 OM COA-613v 06=23� 16 �2016 LOZIER CORPORATION (800) 228-9882 PAGE 3 OF 3 W N � � 'Zz10/ D (n �l D T` �r y r�� < �NOZ Zoz� c oA� � ��R, o r.v�i ��v.. x ��z 0 pm� �mZ � � 1 .Z1 O � m � m c� r D . � � 0 z 1 fTl � N W � D A rn � � Z (7� N 00 C �N W O � m m � .D p I o 0 I o 0 ,ZDj � I N N � � r N � � Z n N -N1 D � � � D � p o Z z � � 0 � � m v T �J �) � �J'�i'�S msote w� co�oa�aox iHIS DMYANG IS THE IXCLUSNE PROPEFfY Of RIE IOZIER CORP. ANO IS i'OR iHE SOIE USE 0 z T rx W v N TOIERANCES uN�ss SPECIFIED: 68647 B 19 32 WAS 1/2, UPDATED LASER AND AREA 03r08 12 � WIPE PROOUCTS USE: ES-38 A RELEASED QT 7076 GI JOE � K NAL• XXX = t.010 INSPECTION ECO REV REVISION DESCRIPTION ORAFfER C NAL• %X = t .03 � DINENSION :noNw: t i/as• uicuutr: t s(e[Nos) TITLE: suvcxsmes: nc: :�Mw :r��u onieRs� WALLMOUNT BRKT — CENTER, TO ATTACH TO SLOTTING �,�,� �., W W ww o cVn N�O D�� m �mN .. � w o� U � v � N C7 � � N m � � o �z D W I � D w N I + rnu A N � m � � D � � m � m z z c o � m m m N � D �D � � I � O m � N D n � m � � D o � z - 0 �'f�3�i mwio w�e ca�oa�im,v TNIS DRAWINC IS TNE EXCWSIVE PROPERfY OF THE LOZIER CORP. NiD IS IOR TXE SOLE USE OF TXE CUSTONER i'OR WHOM R IS INTENDED. TOLERANCES UNLE55 SPECIFIED: DECOYLe 100( c lA1D � �N� DECRI/�L• %K = :.w O xo�n ti/a' EM.IIAI: tt/St' �--+ GR/JN DIRECIION YEIIlIR 31YY � �MGUUR: 3S BENDS) DECN4L• %% � 3.OY :'' .LL onans> .xcowe :�• Z O n A D n � N N w w N V D C � � mr A �� '� n O m �Z �� Z O n A D (� � N W N � IZ ' O O � � �=�AN (n-�cponmoZ-� oNZ����� f�i � ��O r �Zy � � D.. Z Z l • W 0� �� ��N mr � m'l ON D �o� o � � �� � p� DD � C� C� �D� �D orn �� N m O � A � m N � O v �No � w � m" m o i0538 F ADDED COIL MATERIAL TO NOTE 4 AS PRIMARY MATERIAL "'_� _ F PCO REV REVISION DESCRIPTION DRAFTER c TITLE: suvwsmEs WALL MOUNT BRACKET ��„ NOTE: NOTE: THIS DRAWING IS INTENDED FOR PARTS THE PURCHASER OF THE FIXTURE IS RESPONSIBLE FOR DETERMINING THE SUITABIUTY OF ANY IDENTIFICATION ONLY. PLEASE REFER TO SPECIFIC WALL OR STRUCTURE TO WH]CH SHELVING IS ANCHORED, FOR THE SELECTION OF AND/OR INSTALLATION MSTRUCTIONS PACKAGED PROPER INSTALLATION OF THE ANCHORING FASTENERS, HARDWARE AND MATERIALS, AND FOR THE WITH COMPONENTS FOR PROPER ASSEMBLY µ'��MANSHIP OF THOSE PERFORMING ANCHORING. THESL GUIDLLIN6S ARL MPANT TO REQUIREMENTS. ILLUSTRATE TYPICAL TYPES OF ANCHORING AND DO NOT CONSTITUTE ANY ENDORSEMENT BY LOZIER OF ANY SPECIFIC ANCHORING APPLICATION. EACH APPLICATION W[LL VARY DUE TO THE SEE INSTALLATION INSTRUCTIONS: BUILDING, STRUCTURE AND MATERIALS USED FOR ANCHORING, AND PROFESSIONAL ADVICE 85263 SHOULD BE SOUGHT FOR EACH ANCHORED INSTALLATION. FURRING NOTE: 2 x 4 FURRING STRIPS SHOULD BL ANCHORED AT EVERY STUD LOCATION NOT TO EXCEFD 16" DRAWMC TITLE: �u r n ton g SCALG: N.T.S. DRAWN BY: MB DATE: AN INSTALLATION INSTRUCTION) � 5/5/16 DETAiL NO: WALL ANCHOR DETAIL PAGE 1 OF 2 NOTE: NOTE: THIS DRAWING IS INTENDED FOR PARTS THE PURCHASER OF THE FIXTURE IS RESPONSIBLE FOR DETERMINING THE SUITABILITY OF ANY IDENTIFICATION ONLY. PLEASE REFER TO SPECIFIC WALL OR STRUCTURE TO WHICH SHELVING IS ANCHORED, FOR THE SELECTION OF AND/OR INS"IALLATION INSTRUCTIONS PACKAGED PROPER INSTALLATION OF THE ANCHORING FASTENERS, HARDWARE AND MATERIALS, AND FOR THE WITH COMPONENTS FOR PROPER ASSEMBLY WORKMANSHIP OF THOSE PERPORMING ANCHORING. THESE GUIDELINES ARE MEANT TO REQUIREMENTS. ILLUSTRATE TYPICAL TYPES OF ANCHORING AND DO NOT CONSTITUTE ANY ENDORSEMENT BY LOZIER OF ANY SPECIFIC ANCHORING APPLICATION. EACH APPLICATION WILL VARY DUE TO THE SEE INSTALLATION INSTRUCTIONS: BUILDING, STRUCTURE AND MATERIALS USED FOR ANCHORING, AND PROFESSIONAL ADVICE l 1-83 SHOULD BE SOUGHT FOR EACH ANCHORED INSTALLATION. DRAN'MG 7ITLE �u r n ton g SCALE: N.T.S DRAWN BY: MB DATE: OT AN INSTALLATION INSTRUCTIONI I 5/5/16 DCIAIL NO: WALL ANCHOR DETAIL PAGE 2 OF 2 LOZIER SHELVING Receiving Widespan (R19 Series) R19.0 - 4 ft. wide section R19.6 - 6 ft. wide section R19.8 - 8 ft. wide section Widespan: Includes four basic components: Uprite Frames Beams Shelf Supports Shelves Dimensional lnformation: Clear opening between posts: Nominal shelf width plus 1/2" Overall length: (Nominal section width + 1/2") times the number of sections, + 1 3/4" for each post in the run Overall depth: 2 1/4" greater than the nominal depth of the unit Vertical clearance between shelves: Regular Duty Beam: 3 1/4" less than the center-to-center shelf spacing Heavy Duty Beam: 4 3/4" less than the center-to-center shelf spacing Shelves adjustable 2" on center No cross bracing required Welded Uprite Frame Paller Loaded Widespan Considerations: WARNING: Forklifts must not be used, Only hand loader/stacker can be safely used Order "RE" Reinforced Uprite Frames when using hand loader/stacker Shelf supports are required for all applications to stabiliz beam, if not used then beam locking clip is required Aisle side Uprite posts must be anchored to floor Total weight of palletized goods MUST NOT exceed one half of uniformly distributed Beam capacity Allow at least 3" clearance between pallet & Uprite Frame, at least 4" clearance between pallets Pallets should overhang both Beams by at least 2", otherwise Particleboard or Wiregrid Shelves must be used WARNING: Multi-Function Beams are intended to be used with Multi- Function Shelf Supports. If Shelf Supports are not installed then the beams MUST utilize a Widespan Multi-Function Beam Locking Clip (WS1291 or WS9111 pg.706) depending on the beam location. Failure to do this could allow the Beam to become disengaged causing product damage or personal injury. '/StBf� C.,�L I ifF P.O. BOX 3448 • OMAHA, NEBRASKA 68103-0448 •(800) 228-9882 %�j�Z:��� 3/�13 This is a copyrighted work of Lozier Corporation. Any unauthorized reproduction, �'� A distribution or use is expressly prohibited. � O 2013 Lozier� Corporation This dravnng and �ts contents are the excfusve and confident�al property of Lorer Corporat�on and �ts affd�ated companies. The draunng is proNded only for the purposes mtended and shall at all times be kept confidential by the customer or supplier, wiio shall not, �nntho�t the prvor wntten consent of Lozier, diciose, use or d�sseminate, in whole or �n p:rt, thi5 drawing, its contents, or concepts, and shall promptly retum the draKnng upon request without reta�rnng any cop�es thereof. 3 arRe�s�to SECTION A-A I 6 GA. HOT ROLLED S7�EL A57M A60'7 GR 45, CLlSS 2, OR SA� J 1392 Oq5X 45,000 P51 MIN YIELD RLTPRNAT� WELDt�IENT OPTION ?YP BOTti ENDS HOOK DETAIL 1 2 Gh. t10T ROLIED ST�EL HSLA GRADE 50 PER h5T1�1 SPECIFICATION A7 I 5 50,000 P51 IAINIMU�:1 YIELD STRfNGTFi I 2 G+ -A 96 1l8 96 1/2 �:°5896 94 I`9 9A i/2 Vf5B94 92 1;8 92 I/2 4NSB92 84 I/8 84 1/2 V. 5884 '79 i /8 79 I /2 W5879 78 I/8 76 112 W5B78 77 IlB 77 I)2 W5B77 74 1/8 74 I/2 V,'SB74 72 I/8 72 I/2 WS672 70 I/8 70 I/2 WSH70 68 I/8 68 I/2 W5B68 66 i/8 66 I/2 W5866 64 I/8 G4 I/2 WS864 60 I/9 60 I/2 w'S860 59 1/8 59 I/2 V.'Sb59 56 I/8 56 112 WSB56 54 1/8 54 !/2 V✓SB54 48 I/B 48 I!2 WS848 44 I/8 4A I/2 WgB44 42 I/8 42 I/2 W5842 A i I/8 41 I/2 1MSB41 3.i I/8 34 IJ2 VJSB34 28 I/8 28 I/2 1"ASB28 22 I/8 22 I!2 14'SB22 � � PAR7 P10. � � B BEAM LENGTt1 - � �200o LOZIER CORP. STANDARD DUTY BEAM �Zt.�1� 6336 PER5111NG DR. OMAHA, NE 68 ! I 0 I -800-228-9882 WIDESPAN BEAM DETAILS sheEr 1 oF 1 L Th�s drawing and �ts contents are the exciuswe and conRdent�al property of Lozier Corporation and �ts af61�c•ted companies. The drawin9 is proHded only for the purposes mtended and shall at ali times bc kcpt confident�ai by the customcr or supplier, who shail not, withovt thc prior wr7tten conser�t of Lozier, diclosc, use or dissemmate, +n whole or in part, this draw�ng, rts contents, or contepts, and shall promptiy return the dran�ng upqn request without retain�nc� any cop�es tliereoP. 1/8 5 8/ TYP (6) PLS MIN LENGTII _ � (8, p� , I/8 518 MIN LENG711 DETAIL A 7HIS WELDMENT f5 FOR UPRITES TO 8'H. C�2000 LOZIER CORP. Et 5 1 /2 c� �zs.�� 6336 PERS111NG DR. OMAt1A, NE 681 10 I -800-228-9882 TF11S WELDMENT IS FOR UPRITES 9'H TIIROU6H 12'H. D± 5 I /2 Tk115 WELDMENT IS FOR URITE5 ABOVE I 2' WELDMENT DETAILS WIDESPAN UPRITE SHEET 'I OF 4 This drawmg and its contents are the excluswe and conf�deriGal property of 1.4zier Corporat�on and �ts afhliated companies. The drawnng is provided onl f for the purposes �ntended and shail at all times be kept co�hdent�al by the cu5tomer or suppher, �e�ho shaU �ot, w�thout the pnor wntten conaent of Loyer, d�close, vse or dissem+nate, in ufiole or in part, th�s draK7ng, its contents, or concepts, ond shall promptly retum the dravnno upon request Nnthout retairnng any cop�es thereof. --' 36 6 A2 32 118 WSU30042 ""' 36 6 42 26 I/8 1�✓SU24042 """ 36 6 q2 z0I/B W9Ul8042 "'" 36 6 q2 101/8 WSW8042 "' 34 6 40 50 !/8 WSU48040 "'" 32 6 38 32 I/8 1MSU30038 --- 30 6 36 601/8 W5U58036 """ 30 6 36 50I/8 W5U48036 "" 30 6 36 44 I/6 V�U42036 --- 30 6 36 38 I/8 WSU36036 "' 30 6 36 32 1/8 WSU30036 """ 30 6 36 26 I/8 1AraU24036 '"' 30 6 36 20 I/8 WSU18036 '"" 30 6 36 17 I/8 W5U15036 "' 26 6 32 14 I/8 V✓SU12032 "' 24 6 30 50 I/b N�SU48030 "' 24 6 30 44 1/b WSU42030 '"' z� 6 30 38 I JB WSU36030 """ 24 6 30 32 I/8 WSU30030 "' 24 6 30 26 1!6 WSU24030 "' 24 6 30 20 !/8 V✓5U 16030 "' 22 6 28 50 !/8 WSU48028 "' Ib 6 24 50 I/8 WSUA8024 " 18 6 24 44 I/8 lN5UA202R "' 18 6 p4 38 1/8 WSU36024 --- 18 6 24 32 I/8 WSU30024 --- 18 6 24 30 I/8 W5U2802R "' , 18 G 24 26 I/8 WSU24024 "' 18 6 24 23 1/8 W5U21024 "" 18 6 24 20 I/8 WSU 18024 --- I 8 6 24 17 I/8 WSU � 502A "- 12 6 18 20 I/8 WSU18018 B PART E D C NOM A NUMBER HEIGHT �2000 LOZIER CORP. Lz��� 6336 PERS111NG DR. OMAt1A, NE 681 i 0 1-800-228-9882 "' 54 6 66 38 I/8 lR'SU36066 "' S4 6 66 26 I/8 WSU24066 "" 60 6 66 I 7 I/8 V�SU I 5066 �-' SA 6 66 14 I/8 UlSU12066 "' 54 6 60 60 I i8 WSU58060 "" 5`� 6 60 50 I/8 W5U48060 "' �a 6 60 44 I/B WSU42060 "' 5a 6 60 38 UB M�5U36060 --- 54 6 60 32 I/8 W5U30060 , --- 54 6 60 26 1/8 WSU24060 ""' S4 6 60 24 IJ8 WSU22060 "' Sa 6 60 22 Il8 WSU20060 "' S'� 6 60 20 I!8 WSU I 8060 "' S4 6 60 I 7 I/8 W5U I 5060 ""' S4 6 60 I 4 1/8 W5U I 2060 --- 48 6 5A 50 I/8 WSU48054 '"" 48 6 54 44 1/8 VJSU42054 "" 48 6 54 38 I/8 N'SU36054 '-' 48 6 54 32 1t8 WSU30054 "' 48 6 54 26 I/8 iN5U24054 -" 42 6 A8 50 I/8 NE5U48048 "'" 42 6 48 44 !/8 N.'SU42048 "' 42 6 48 38 I/8 WSU36048 —' 42 6 48 36 I/8 Vv5U34048 '"' 42 6 48 35 I/8 WSU33048 "' 42 6 48 32 �/8 WSU300Ab "' 42 6 48 26 1/8 W5U24048 "" '12 6 48 22 1/8 W5U20048 "' '�2 6 48 20 I 18 WSU I 8048 "' 42 6 A8 I 8 I/8 WSU I 6�48 ""- 42 6 48 ! 7 I/8 WSU 15048 "' 42 6 48 I A I/8 WSU I 2048 "' 36 6 42 50 !/8 WSU48042 "' 36 6 a2 44 !/8 WSU42042 "'" 36 6 42 38 I/8 WSU36042 E D C ��A q PART HE16HT NUMBER WIDESPAN UPRITE Sf1EET 2 OF 4 Th�s draw�ng and its contents are the exclusive and confidential property of Loz�er Corporation and �t5 affihated compames. The dra�amg is prc�nded only for the purposes intended and shall at all times be kept confidential by the customer or supplier, who shall not, without the prior untten con5ent of Lozier, diclo5e, use or d�ssem�nate, in whole or m part, thi$ drawing, its contents, or concepts, and shall promptly return the dr:,w�ng upon request v.�thout reta�rnng arry cop�es thereof. """ 78 12 96 32 I/8 WSU30096 ""' 78 12 96 26 !/B W5U24096 "'" 78 I 2 96 20 1/8 WSU I 8096 "" 78 12 96 17 I/8 WSU15096 '"" 78 12 96 14 I/8 WSU12096 '"' 78 12 �0 501l3 WSU48090 -"' 78 12 90 441/8 WSU42030 --" 7B 12 90 38 I/8 WSU36090 --- 72 12 84 b0 118 WSU58084 . """ 72 I 2 84 50 I/8 �NSU48084 �� "" 72 12 84 46 1 J8 W5U44084 """ 72 I 2 84 44 1/8 WSU42084 """ �2 12 84 381/8 WSU36084 """ 72 I 2 84 32 !/8 W'SU30084 "" 72 12 84 26 i/8 WSU24084 --- 72 I 2 84 20 I/8 N5U I 8p84 -" 72 12 84 18 U8 WSU16084 "' 72 12 84 17 I!B WSU15084 """ 72 12 $4 I 4 I/8 WSU I 2064 66 I/4 �2 78 I!4 38 I/8 W5U36078.25 �-- 66 I/A 12 78 I/4 32 1/8 WSU30078.25 --- 66 1/4 � 2 78 I/4 26 I/8 WSU24078.25 '�- 66 ! 2 78 60 I/8 WSU58�78 -'- 66 ! 2 7b 38 Ii8 WSU36078 '-- 66 12 78 32 I/8 W5U30078 --- 60 12' 72 50 I/8 WSU48072 --- 60 ! 2 72 46 I/8' WgU44072 "" 60 12 72 44 I/8 1NSU42072 "' 60 12 72 38 I/8 1NSU36072 ""' 60 12 72 32 !/8 WSU30072 "' 60 I 2 72 26 I/8 W5U24072 --- 60 12 72 221/8 WSU20072 --- 60 12 72 20 118 WSU I 8072 --- 60 I 2 72 I 7 I/8 YdSU I 5072 "' 60 I 2 72 I 4 I/B N^5U I 2072 B PART E D' C NOie A NUMBER nei�nr QG 2000 LOZIER CORP. �Z.t.�'.1�� 6336 PERSHING DR. OMAf1A, NE 681 10 1-800-228-9882 461/2 !6B 12 180 501/6 W5U48180 42 I/2 150 6 156 54 I/8 WSU52156 54 1/2 132 12 144 601/8 W5U5814A 54 I/2 132 12 144 50 I/$ L",'SU48144 54 1/2 132 I 2 I44 46 1/8 WSUGA I A4 54 I/2 132 12 144 44 I/8 1h�5U42144 54 1/2 132 12 !44 38 I/8 WSU361q4 54 I/2 132 12 !44 32 1/8 WSU30144 5A I/2 ! 32 I 2 144 30 t/B WSU28144 54 I/2 !32 12 144 261/8 W5U24144 qg t/2 ! 14 6 I 26 20 I/8 WSU 18126 42 I/2 108 12 120 601/8 WSU58120 42 I/2 i 08 � 2 I 20 50 I/8 WSU48 I 20 42 I/2 !08 12 120 44 I!8 W$U42120 �i2 �/2 108 �2 120 38 I/8 WSU36120 42 I/2 !08 12 120 32 I/8 WSU30120 42 I/2 !08 12 120 301/8 WSU28120 42 I/2 !08 12 120 26 I/8 W5U24120 42 I/2 108 I 2 120 20 I/8 tNSU I 8120 42 l/2 ! 08 12 ! 20 14 1/8 WSU 1 2120 QZ �IZ 102 6 I 14 32 I/8 W5U30I 14 42 !I2 102 6 108 54 1!8 WSU52108 42 !/2 102 6 108 50 I/8 WSU48108 42 !/2 102 6 !08 44 I/8 WSU42108 42 1/2 102 6 108 38 1J8 W5U36�08 42 I/2 l 02 6 I OB 32 1/8 VJSU30 � 08 42 I!2 102 6 108 301/8 WSU28108 42 I/2 102 6 108 27 1!8 W5U25108 42 I/2 102 6 108 261/8 W5U24108 a2 I/2 I o2 6 I o8 20 I/8 WSu 181 ob 42 I/2 102 6 !08 �7 �/8 W�U15108 39 1J2 96 6 102 26 I/8 W5U24102 "' 76 ! 2 96 60 I/8 WSU58096 '"' 78 ! 2 96 50 !/8 Yb5U48096 -'" 76 12 96 44 1/8 WSU42096 '"' 78 12 96 38 I/8 WSU36096 B PAR7 E D C NOM A NUt�IBER HEIGH7 WIDESPAN UPRITE shE�r 3 0� 4 � This drawing and its conte�ts are the excluswe and conBdential property of Lozier Corporabon and its affiliated companies. The drsvnng is prov�ded only for the purposes intended and shali at all t�mes be kept conf�dent�al by the tustomer or suppl�er, who shail not, w�thout the prior written consent of lozier, diclose, use or dissemmate, in whole or in part, this dravuing, its contents, or concepts, and shall promptly return Lhe drav,�ng upon reqvest Hnthout retairnng ary copies thereof, �?�c ~�` � �) � � �32 �'�_,� _ I � 3 4 HOR1Z. AND DIAG. BRACE MATERIAL SPEGFICATIONS: 375 I. 3/4 X I ! I/32 X 20 GA. WALL STEEL TUBING. 2.000 _ TYf' . I 50 REF . I 50 REF I .800 MAX (A7 . ! 50 OFFSET) � 3 I /64 TYF' �I I f-- I .625 14 GA. POST MATERIAL SPECIFICATION SPECIFICATlONS: 110T ROLLED I.000 TYP AS7M A570 GR 45 OR EQUIVALENT. TI1fCKNESS: .0720 MINIMUM. I � .344 TYP � � - � �1 � o �1 Cl � o �312TYP FRONT OF POST .562 7YP I .750 ±.0 I 5 � .000 TYP � 344 iYP C(�2000 LOZIfR CORP. �irZs.�,�! 6336 PER5f1ING DR. OMAHA, NE G81 10 i -800-228-9882 ❑ ❑ ❑ SIDE OF POST 2.000---i I--- .344 TYP TYP WIDESPAN UPRITE 5t1EET 4 OF 4 INSTA��ATION INSTRUCTIONS WIDE SPAN SHELVING NOTE: WIDE SPAN BEAMS ARE IDENTIFIED BY A WS STAMPED INTO THE RIGHT END OF EACH BEAM. See page 2 for Reinforced Uprite ITEM PART NUMBER DESCRIPTION 1 WSU_ Uprite Frame 2 WSB_ Beam 3 WSSS_ Shelf Support 4 WSWG_ Wiregrid Shelf 5 WSB_HD Heavy Duty Beam 6 WSSS_HD Heavy Duty Shelf Support 7 WSPB_HD Heavy Duty Shelf 8 WSUC Uprite Connector 9 WS1241 Floor Anchor • 10 WS1251 Floor Protector/Shim 11 WS1291 Beam Locking Clip 12 50106 5/16"-18 x 2 1/2" Carriage Bolt 13 51005 5/16"-18 Hex Nut 14 WS1231 Back to Back Connector 15 WSU RE Reinforced Uprite Frame 16 WS1321 Top Cap 17 WS9111 Beam Locking Hardware PLEASE NOTE: Personnel must be provided with safe access to all elevations of storage equipment or display fixtures via ladders, stairways, or other means in accordance with applicable OSHA regulations. In NO case should anyone be allowed to climb or stand on storage or display equipment. .a ����� OMAHA, NEBRAS A D6I8E10 �ZPCOA-746 1A=2�515 �2015 LOZIER CORPORA710N . �800� 228-9882 PAGE 1 OF 12 48" INSTA��ATION INSTRUCTIONS '^�'�� SPAN SHELVING Reinforced Uprite Frame (Item 15) NOTE 1: Wide Span Uprite Frames are available in standard duty for normal use or reinforced for use with hand stackers. (See User Instructions on page 10 for capacities.) NOTE 2: Either of two beam types may be used with the Wide Span System (See User Instructions on page 9 and page 10 for capacities). The Standard Duty Beam (Item 2) is 3 1/4" high. The Heavy Duty Beam (Item 5) is 4 3/4'� high. Reinforced Uprite Frames (Item 15) have a channel shaped reinforcement member in the lower portion of each post. They also have a welded foot plate to secure the post to the floor. Standard Duty Uprite Frames (Item 1) DO NOT have the reinforcement member. 0 Standard Duty Beam (Item 2) 0 Heavy Duty Beam (Item 5) .d ����� OMAHA, NEBRAS A D 6I81 10 �LZPCOA-746V � A36 m2015 LOZIER CORPORATION (800) 228-9882 PAGE 2 OF 12 I NSTA��ATION I NSTRUCTIONS WIDE SPAN SHELVING SELF—RETAINING WIDE SPAN BEAM INSTALLATION These Wide Span Beams are designed with Self—Retaining Lower Hooks on the End Connectors. The beam must be tilted so the longer lower hook can be inserted into the post slot first CORRECT STEP I: Tilt top of beam and insert lower hooks into slots. INCORRECT STEP 2: Rotate top of beam forward so top hooks ore inserted into slots. STEP 3: Seat the hooks downward into the slots. � TILT BACK �START LOWER HOOK INTO SLOT �ROTATE FORWARD BOTH HOOKS INTO SLOTS SEAT HOOKS INTO SLOTS ... 0���� OMAHA, NEBRAS A D 6I81 10 �LZPCOA-746V � A37 �2015 LOZIER CORPORATION �800� Z2H-9SHZ PAGE 3 OF � Z INSTA��ATION INSTRUCTIONS WIDE SPAN SHELVING NOTE 3: Two styles of Shelf Supports may be used depending upon beam type: Standard Duty Shelf Supports (Item 3) are 2-17/32" high and "n" shaped. These are used with Standard Duty Beams. Heavy Duty Shelf Supports (Item 6) are 4" high and "n " shaped. These are used with Heavy Duty Beams. NOTE 4: Two Shelf types may be used: 2 1 -�I 1 13/ 16" I� Standard Duty Shelf Support (Item 3) Heavy Duty Shelf Support (Item 6) 3x3 Wire Grid (Item 4). Heavy Duty Shelves (Item 7) are 5/8" thick, hinh—c�rr�nn�h nnrtirlA hnnrri e-oe ����� OMA A6 NEBRAS A D 681 10 �LZPCOA-746 � A3$ �2015 LOZIER CORPORATION (800) 228-9882 PAGE 4 OF 12 INSTA�LATION INSTRUCTIONS WIDE SPAN SHELVING 1. ASSEMBLY OF BASIC UNIT NOTE: To provide for beams height adjustments, allow a 2" gap between wall and face of uprite (See Detail B) or between faces of both uprites in back—to—back applications or use back—to—back connectors (Item 14) (See Detail C). WALL ����� � �� � 2„ I UPRITE I � 2„ UPRITE UPRITE ~i DETAIL B DETAIL C Top View of Uprite Frames a. Stand two frames vertically (NARROW ENDS OF SLOTS DOWNWARD). Diagonal bracing on alternate uprite assemblies should face opposite directions per illustration on page 1. WARNING: BE SURE REINFORCED UPRITES (Item 15) ARE INSTALLED IN AREAS WHERE HAND STACKERS ARE TO BE USED. b. Install one beam at lowest desired level. IF THE BOTTOM OF THIS BEAM IS MORE THAN 6" FROM THE FLOOR, THEN THE UPRITE MUST BE ANCHORED. Both ends of beam must be inserted into the uprite slots at the same time. (See Detail D) c. Install opposite side beam, following same procedure as outlined above. d. Install remaining beams at desired levels. Maximum beam spacing is 48" to maintain the uprite rated load capacities. CAUTION: IF CERTAIN LEVELS ARE TO BE HEAVY DUTY, BE SURE HEAVY DUTY BEAMS ARE INSTALLED AT THOSE LEVELS. REFER TO LOADING INFORMATION IN USER INSTRUCTIONS ON PAGES 9 AND 10. UPRITE HOOK ����� � � � •• CORRECT DETAIL D INCORRECT (Top View of Uprite Post and Left End of Beams) TOP CAP NOTE: Be sure that: —Hooks on all beams are properly seated and are square with uprites. (See Detail E) —All beams are installed parallel with the floor. —Front and rear beams of each pair are installed at same height. —If top Lance in Uprite is going to be used remove Top Cap to insert Beam Hook and reinsert Top Cap (See Detail E). BEAM UPRITE DETAIL E � ����� OMAHA, NEBRAS A D68E10 �LZPCOA-746 � A39 �2015 LOZIER CORPORATION (800) 228-9882 PAGE 5 OF 12 NSTA��ATION INSTRUCTIONS WIDE SPAN SHELVING e. When shelves are used, install Shelf Supports per Details F, G, and H. Shelf Support locations in the beams are as shown in Details F. � 2 Shelf Supports �,,..,�, �.,��y�, 48: X=12" 60: X=12" 72: X=18„ 96: X=24" 4 Shelf Supports � �I X -- — �-.. 48: X=6";Y=12" 60: X=6";Y=12" 72: X=6";Y=20" 96: X=6";Y=28" X I� DETAIL F (View From Top) � 3 Shelf Supports tfeam Length 48: X=8"; Y=16 60: X=8"; Y=22 72: X=12"; Y=24 96: X=12"; Y=36 5 Shelf Supports - — -- �- 48: X=6";Y=9" 60: X=6";Y=12" 72: X=6";Y=15" 96: X=6";Y=21 " f. Shelf Supports (Item 3) are installed by laying them sideways between the beam flanges, then rotating them to vertical (See Detail G and H). � X I� If outer supports fit to tightly, install them near center of the beams. Then slide them outward to the positions noted in Detail F above. BEAM (ITEM 2 OR 5) � SHELF SUPPORT (ITEM 3 OR 6) DETAIL G BEAM (ITEM 2 OR �� SHELF SUPPORT (ITEM � _ _, DETAIL H .-0. ����� OMA A6 NEBRAS A D 6I81 10 �LZPCOA-746V � A4O �2015 LOZIER CORPORATION �800� 228-9882 PAGE 6 OF 12 INSTAL�ATION INSTRUCTIONS 2. FLOOR ANCHOR WIDE SPAN SHELVING Floor anchors are required when: a. The ratio of the height of the unit to the overall depth of the unit exceeds 6:1. b. Alignment of rows need to be maintained. c. When hand stackers are used. d. Post load needs to be spread over a larger area. e. When bottom of the bottom beam is more than 6" from the floor. Bolt floor anchor onto the bottom of the post using hardware provided as shown in Detail I. Anchor to floor using a wedge—style anchor suitable for concrete. Anchor material, finish, diameter and embedment shall be determined by the customer for the specific site requirement. The minimum anchor diameter shall be 1/4" and the minimum embedment shall be 1 1/8". NUT FOR CONCRETE ANCHOR f.l�:��l�� FLOOR ANCHOR (ITEM 9) CONCRETE ANCHOR 5/16"-18 X 2 1/2" CARRIAGE BOLT (ITEM 12) 3. FLOOR PROTECTOR/SHIMS � Floor protector/shims are used to protect floors when required and/or to aid in leveling the system when required (by stacking the shims). , NOTE: FLOOR PROTECTOR/SHIMS CANNOT BE USED IN CONJUNCTION WITH . FLOOR ANCHOR PADS. a. Install after assembly of basic unit by lifting one uprite at a time and then positioning shim (or shims) as shown in "Detail J". Do not exceed 5 shims under any post. DETAIL J UPRITE POST FLOOR PROTECTOR/SHIM (ITEM 10) � �uU�� OM HA6 NEBRAS A D 681 10 �LZPCOA-746 � A4� �2015 LOZIER CORPORATION (800) 228-9882 PAGE 7 OF 12 INSTA��ATION INSTRUCTIONS WIDE SPAN SHELVING 4. UPRITE CONNECTOR Uprite connectors are required for two—piece uprite frames (those over 10' tall), and when adding height to existing installations. On two—piece uprite frames and on extension frames, the lower uprite frame should be equal to or greater in height than the upper uprite frame. a. Remove Top Caps from lower uprite frame. b. Slide a connector channel into the bottom of each leg of the upper uprite frame. MAKE SURE THE "C" CHANNEL SHAPE IS OPPOSITE THAT OF THE UPRITE POST. Slip the carriage bolt through the square hole at the front of the upper uprite post, then through the insert, then through the clamp. Install the nut loosely. When both connectors are installed, raise the upper uprite frame into place per Detail L and tighten nuts snug. DO NOT over tighten as it will deform the face of the post. CARRIAGE BOLT CLAMP ° N UT CONNECTOR CHANNEL � � • K� (HOLE NOT USED) DETAIL K UPPER UPRITE POST r.� � i 'O i io i � � CONNECTOR CHANNEL ;o � � � CLAMP � , � ;o ; � , � , 'o � � , � � UNUSED HOLE AT BOTTOM BOTTOM UPRITE POST DETAIL L 5. BACK—TO—BACK CONNECTORS Back—to—back connectors are used to space back—to—back sections of Wide Span to allow beam ad justment. a. Set Uprite Posts into slots in connector on floor (Detail M). (When floor anchors are used, lower back—to—back connector is not needed.) b. Place one connector over tops of back—to—back posts (Detail N), after removing Top Caps. DETAIL M DETAIL N BACK—TO—BACK CONNECTOR .a �U��� OMA A6 NEBRAS A D68110 �LZPCOA-746 � A42 �2015 LOZIER CORPORATION �$OO� ZZH-9H82 PAGE H OF � Z INSTA��ATION INSTRUCTIONS WIDE SPAN SHELVING STEP 6: BEAM LOCKING: Beam locking clips (WS1291) or locking hardware (WS9111) must be used in the following applications: — When beams are used singly, not as a beam pair with connecting shelf supports — When hand stackers may be used to load and/or unload shelves — When beam pairs will be used as tire racks Locking clips must be oriented so that their tapered legs align with the tapered sides of the shelf slots in the uprite post. The clips will not lock the beams unless they are correctly oriented when installed. Insert the beam locking clip into the portion of the uprite slot above the beam connector hook, as shown in Detail B. Always install the clip in the slots shown. WARNING: DO NOT INSTALL THE LOCKING CLIP IN THE SLOT WITH BOTTOM HOOK OR THE TOP HALF SLOT OF THE UPRITE. THE CLIP WILL NOT LOCK THE BEAM IN THOSE SLOTS. TAPER 0 ° O BEAM LOCK WSB_ o CLIP WS1291 �� (ITEM 11) � I I � 0 o � LOCKING CLIP SLOT IN POST WSB_HD 0 o O o °� DETAIL P DO NOT INSTALL LOCKING CLIP HERE BEAM LOCK CLIP WS1291 (ITEM 1 1) EXTENSION CONNECTOR CLAMP DO NOT INSTALL LOCKING CLIP HERE Position clip so taper of clips legs matches taper of the slot in post. 5/16-18 HEX NUT DO NOT INSTALL A LOCKING CLIP IN TOP SLOT o O o Q SECURE WITH e o 5/16 BOLT WSB_ AT TOP OF WSU_: BEAM LOCKING HARDWARE WS9111 (ITEM 17) STEP 7:TIRE RACK ASSEMBLIES: The tire rack is assembled from standard components by following instructions on preceding pages. Use one shelf support near the center of each pair of beams to prevent the beams from spreading. WARNING: BEAM LOCKING CLIP MUST BE USED ON ALL TIRE RACK BEAMS TO RESTRAIN BEAMS FROM BECOMING DISLODGED. � ����� 6336 PERSHING DRIVE 01-60 REv. a4 q43 OMAHA, NEBRASKA 68110 LZPCOA-746 -- �2015 LOZIER CORPORATION (800) 228-9882 PAGE 9 OF 12 INSTA��ATION INSTRUCTIONS WIDE SPAN SHELVING POST IN CONSPICUOUS PLACE WARNING: OVERLOADING, MISUSE, ABUSE OF THE WIDE SPAN SYSTEM CAN CONTRIBUTE TO COLLAPSE AND PERSONAL INJURY! PLEASE NOTE: Personnel must be provided with safe access to all elevations of storage equipment or display fixtures via ladders, stairways, or other means in accordance with applicable OSHA regulations. In NO case should anyone be allowed to climb or stand on storage or display equipment. A. LOADING AND CAPACITY LIMITATIONS 1. Uprite assembly - 10,000 pounds per uprite assembly moximum: - Beams spaced not more than 48" vertically on center. - Post anchored to floor if bottom of bottom beam is more than 6" from floor 2. Standard Duty Beams (Hand Loaded Only) WARNING: THESE CAPACITIES ARE FOR EVENLY DISTRIBUTED LOADS. CONCENTRATED LOADS REDUCE THESE CAPACITIES 50�. a. Maximum evenly distributed static load capacities per shelf with shelf supports (WSSS) and 5/8" thick particle board shelf (WSPB). Widespan Shelf Capacity (Uniformly Distributed Load) Section Section Width Number of Regular Duty Number of Heavy Duty Depth (Beam Length) Shelf Supports with Shelf Supports with Regular Duty Beams Heavy Duty Beams 2 3 4 2 3 48" 1,600 2,400 3,000 3,000 Up to 60" 1,600 2,400 2,400 ---- 3,000 36"D 72�� 1,600 2,000 2,400 ---- 3,000 84" 1,600 1,800 2,000 ---- 3,000 96" 1,600 1,600 1,600 ---- 3,000 48" 1,370 2,055 2,740 ---- 3,000 Up to 60" 1,370 2,055 2,400 ---- 3,000 42"D 72�� 1,370 2,000 2,200 ---- 3,000 84" 1,370 1,800 1,600 ---- 3,000 96" 1,370 1,600 1,600 ---- 3,000 48" 1,200 1,800 2,400 ---- 3,000 Up to 60" 1,200 1,800 2,400 ---- 3,000 48"D 72�� 1,200 1,800 2,000 ---- 3,000 84" 1,200 1,700 1,800 ---- 3,000 96" 1,200 1,600 1,600 ---- 3,000 b. Capacities per pair of beams (with the required number of shelf supports (WSSS) to tie beams together) when load is placed across beams with no shelf. Length Capacity No. of Shelf Supports (Std. Duty) Req. Per Pair of Beams 48�� 3,000 Ibs. 1 60" 2,500 Ibs. 1 72" 2,000 Ibs. 3 gg" 1,600 Ibs. 3 3 Standard Duty Beam � ����� OMAHA, NEBRAS A D 6I81 10 �LZPCOA-746V � A44 �2015 LOZIER CORPORATION �800� Z2H-g$HZ PAGE � O OF � L I NSTA��ATION I NSTRUCTIONS WIDE SPAN SHELVING 3. Heavy Duty — Three (3) heavy duty shelf supports are required per pair of beams. a. Hand Loaded: 3,000 pounds per pair of beams (all lengths) — evenly distributed load. 4; WARNING: CONCENTRATED LOADS REDUCE THIS CAPACITY BY 5^% b. Hand Stacker Loaded: 2— 1,000 pound pallets per pair of beams. 1— 1,500 pound pallet per pair of beams. )uty Beam WARNING: HAND STACKERS (WALKER STACKERS) ONLY ARE ALLOWABLE. RIDER LIFT TRUCKS OF ANY TYPE ARE NOT ALLOWABLE. — Beams must be heavy duty (WSB_HD) — Beam locking clips are required on all aisle—side beams. — Floor anchors are required on all aisle—side posts. — Uprites (WSU_RE) with reinforcement members MUST be used. — Pallets MUST sit on front and rear beams. — Pallet sizes will be limited by the space between uprite posts, required between pallets and between pallets and �osts. Approximately 3" clearance is Hand Stacker Forklift Truck .-0. ����� OMAHA, NEBRAS A D 6I81 10 �LZPCOA-746 � A45 �2015 LOZIER CORPORATION �BOO� 2ZS-gSHZ PAGE � � OF � 2 INSTA��ATION INSTRUCTIONS WIDE SPAN SHELVING B. SAFETY PRECAUTIONS — In order to assure that the Wide Span Shelving is used in a safe manner, the following safety precautions must be observed. 1. Racks MUST be installed strictly according to the manufacturers instructions. 2. Never overload the uprites or beams (See Section A on pages 10 and 1 1). 3. Be sure the shelving sections remain aligned. 4. When the height of the rack is more than 6 times the depth, floor anchors must be used. 5. Never use damaged parts. Damaged parts may cause shelving to be structurally unsafe or create exposure to sharp or pointed edges. If parts were damaged in shipment, do not use and contact your Lozier Customer Service Representative. If parts are damaged after shipment, discontinue use immediately and order replacement parts. 6. Never alter, modify or otherwise structurally change the shelving or any of its component parts. Modification or alteration may cause the shelving or component part to become structurally unsafe resulting in tipping, collapse or other failure of the fixture. 7. If any shelf support or beam becomes partially or completely dislodged, it must be corrected immediately. 8. Do not use the installed Wide Span Rack as a ladder, walkway, or work platform. 9. Do not lean tall or heavy items against shelving unless shelving is anchored to a suitable building wall, to the floor, or is otherwise braced to prevent overturning. The weight and force of leaning items on unanchored or unbraced shelving may cause the shelving to overturn or collapse. 10. Shelving (or racks) that are leaning or bending when loaded may indicate a dangerous overload or impending collapse. Loads should be immediately reduced, and the cause for this condition should be corrected, before reloading. Refer to appropiate installation instructions to assure shelving (or racks) are properly assembled, replace any damaged components or parts, and do not exceed recommended maximum loads or engage in any other unsafe use of the shelving (racks). .a ����� OMA A6 NEBRAS A D 6I81 10 �ZPCOA-746V � A46 �2075 IOZIER CORPORATION �$OO� ZZS—gSBZ PAGE � Z OF � 2 APPENDIX B TYPICAL COMPONENT DESIGN CALCULATIONS .1oB: 16279 DATE: 07/07/16 JOE P. HILL, P.E. BY: Cp CH�: JPH CONSULTING STRUCTURAL ENGINEERING 1801 N. HAMPTON RD., SUITE 440 DESOTO, TX 75115-2399 972-283-5111 E-Mail:Joe@jphpe.com B� Company : Designer : Job Number: Section Properties: WS BEAM SECTION 16GA (0.061 ") Section Information: Material Type Shape Type Number of Shapes Basic Properties: Total Width Total Height Centroid, Xo Centroid, Yo X-Bar (Right) X-Bar(Left) Y-Bar(Top) Y-Bar(Bot) Max Thick Equivalent Properties: Area, Ax Inertia, Ixx Inertia, lyy Inertia, ixy Sx (Top) Sx (Bot) Sy (Left) Sy (Right) rx ry Plastic Zx Plastic Zy Torsional J As-xx Def As-yy Def As-xx Stress As-yy Stress = General = Arbitrary = 5 = 1.689 = 3.250 _ -0.282 = 0.193 = 0.502 = 1.187 = 1.433 = 1.817 = 0.061 = 0.439 = 0.621 = 0.128 _ -0.069 = 0.433 = 0.342 = 0.108 = 0.255 = 1.190 = 0.540 = 0.459 = 0.202 = 0.001 = 1.000 = 1.000 = 1.000 = 1.000 in^2 in^4 in^4 in^4 in^3 in^3 in^3 in^3 in in in"3 in^3 in^4 Section Diagram C:\RISA Section Files\WIDESPAN BEAM.nmsx g2 Company : Designer : Job Number: Section Properties: WS UPRITE 14GA (0.072") Section Information: Material Type Shape Type Number of Shapes Basic Properties: Total Width Total Height Centroid, Xo Centroid, Yo X-Bar (Right) X-Bar(Left) Y-Bar(Top) Y-Bar (Bot) Max Thick Equivalent Properties: Area, Ax Inertia, Ixx Ine�tia, lyy Inertia, Ixy Sx (Top) Sx (Bot) � Sy (Left) Sy (Right) � ry Plastic Zx Plastic Zy Torsional J As-xx Def As-yy Def As-xx Stress As-yy Stress = General = Arbitrary = 2 = 1.625 = 1.750 = 1.176 = 0.446 = 0.878 = 0.747 = 0.875 = 0.875 = 1.625 = 0.372 = 0.202 = 0.133 _ -0.000 = 0.231 = 0.231 = 0.178 _ �0.151 = 0.738 = 0.597 = 0.265 = 0.200 = 0.001 = 1.000 = 1.000 = 1.000 = 1.000 in^2 in^4 in^4 in"4 in^3 in^3 in^3 in"3 in in in^3 in^3 in^4 Section Diagram C:\RISA Section Files\WIDESPAN BEAM.nmsx B3 Company : Designer : Job Number: Section Properties: WS BRACINGS 20GA Section Information: Material Type Shape Type Number of Shapes Basic Properties: Total Width Total Height Centroid, Xo Centroid, Yo X-Bar (Right) X-Bar(Left) Y-Bar(Top) Y-Bar (Bot) Max Thick Equivalent Properties: Area, Ax Inertia, Ixx Inertia, lyy Inertia, Ixy Sx (Top) Sx (Bot) Sy (Left) Sy (Right) rx ry Plastic Zx Plastic Zy Torsional J As-xx Def As-yy Def As-xx Stress As-yy Stress = General = Arbitrary = 2 = 0.750 = 1.342 = 2.804 = 0.557 = 0.375 = 0.375 = 0.671 = 0.671 = 0.033 = 0.115 = 0.024 = 0.010 = 0.000 = 0.035 = 0.035 = 0.027 = 0.027 = 0.453 = 0.298 = 0.046 = 0.032 = 0.000 = 1.000 = 1.000 = 1.000 = 1.000 in^2 in^4 in^4 in^4 in^3 in^3 in^3 in^3 in in in^3 in^3 in^4 Section Diagram C:\RISA Section Files\WIDESPAN BEAM.nmsx B4 Company : Designer : Job Number: Section Properties: 19-shelf Section Information: Material Type Shape Type Number of Shapes Basic Properties: Total Width Total Height Centroid, Xo Centroid, Yo X-Bar (Right) X-Bar(Left) Y-Bar (Top) Y-Bar(Bot) Max Thick Equivalent Properties: Area, Ax Inertia, Ixx Inertia, lyy Inertia, Ixy Sx (Top) Sx (Bot) Sy (Left) Sy (Right) rx ry Plastic Zx Plastic Zy Torsional J As-xx Def As-yy Def As-xx Stress As-yy Stress � � � General Arbitrary 3 19.170 1.400 9.646 1.226 9.553 9.618 0.208 1.192 0.030 0.864 0.115 29.272 -0.007 0.555 0.097 3.044 3.064 0.365 5.822 0.169 4.377 0.000 1.000 1.000 1.000 1.000 in^2 in^4 in^4 in^4 in^3 in^3 in"3 in^3 in in in^3 in^3 in^4 Y� � tl.ilo eeie I„ �$o �_ -$��f-- - --- --- -- - --- i �- - - -�- - - - -- - --- ;; � i � Section Diagram C:\RISA Section Files\GONDOLA-NEW.nmsx - B5 Company : Designer : Job Number: Section Properties: 22-shelf Section Information: Material Type = General Shape Type = Arbitrary Number of Shapes = 3 Basic Properties: Total Width Total Height Centroid, Xo Centroid, Yo X-Bar (Right) X-Bar(Left) Y-Bar (Top) Y-Bar (Bot) Max Thick Equivalent Properties: Area, Ax Inertia, Ixx Inertia, lyy Inertia, Ixy Sx (Top) Sx (Bot) Sy (Left) Sy (Right) � ry Plastic Zx Plastic Zy Torsional J As-xx Def As-yy Def As-xx Stress As-yy Stress = 22.169 = 1.400 = 11.098 = 1.242 = 11.116 = 11.054 = 0.190 = 1.210 = 0.030 = 0.959 = 0.119 = 43.174 = 0.008 = 0.627 = 0.099 = 3.906 = 3.884 = 0.353 = 6.710 = 0.172 = 5.600 = 0.000 = 1.000 = 1.000 = 1.000 = 1.000 in^2 in^4 in^4 in^4 in"3 in^3 in^3 in^3 in in in^3 in^3 in^4 Yt _ a,n i�ov i� +vii > • §�-^�-- - --- �---- - ------- ---- a � � � Section Diagram C:\RISA Section Files\GONDOLA-NEW.nmsx - B6 Company : Designer : Job Number: Section Properties: GONDOLA UPRIGHT OPN Section Information: Material Type = General . _ __ _ __ _ _-- - - -- --- __ - Shape Type Arbitrary _ _ -- -- _ _— _ - Number of Shapes = 6 Basic Properties: ---_ _ Total Width 1.899 in _ _ ___ _ --------- - _ Total Height 2.593 in . . .._ _'.._. _.__. .._- __-- - ...__._ _ _ ____. __ .. Centroid, Xo = 0.990 in .__._ __._ . ......_._ .__.__ ______- Centroid, Yo = 1.372 in X-Bar (Right) = 0.950 in X-Bar (Left) = 0.950 in Y-Bar (Top) = 1.296 in Y-Bar (Bot) = 1.297 in Max Thick = 2.531 in Equivalent Properties: Area, Ax = 0.757 in^2 _._. _----- - --- _ - - — Inertia, Ixx = 0.817 in"4 _ __ - --- - ----- __ _ ..__ _ _ --�-- Inertia, lyy 0.237 in 4 _ _ _ - -- ---- _—__ _ .---- Inertia, Ixy - 0.000 in^4 Sx (Top) = 0.630 in^3 _ __--- - - __ - _ __ _ _ _ Sx (Bot) = 0.630 in^3 _ -- ------ - -- - _ - _ _ Sy (Left) = 0.250 in^3 ___ __ _ --- -___ -__ _.__ __ Sy (Right) 0250 in^3 . _ _---- rx = 1.039 in __ _ _ _--- - -- __ ------- _ . _ ry = 0.560 in _ . --- -- — __ _ _ Plastic Zx = 0.746 in^3 -- _ _— _ __ _ _ Plastic Zy = 0.406 in^3 _ . -- -- _ ___ _ _ _. _ _ _ Torsional J = 0.005 in^4 _ . --- _---- --- _. As xx Def = 1.000 _ -- -_ _-- —__ _ _--- __ As-yy Def = 1.000 -- -- _ _ — ---___ _ As-xx Stress = 1.000 _ _--- __ As-yy Stress = 1.000 Y� ,_ . ,�, _ � o ceo o sse _._,�,�... ,�� . _...._ . ..I.� ....__ . _ .�I Section Diagram C:\RISA Section Files\GONDOLA-NEW.nmsx g7 Company : Designer : Job Number: Section Properties: HD GONDOLA UPRIGHT OPN Section Information: Material Type Shape Type Number of Shapes Basic Properties: Total Width Total Height Centroid, Xo Centroid, Yo X-Bar (Right) X-Bar(Left) Y-Bar(Top) Y-Bar(Bot) Max Thick Equivalent Properties: Area, Ax Inertia, Ixx Inertia, lyy Inertia, Ixy Sx (Top) Sx (Bot) Sy (Left) Sy (Right) rx ry Plastic Zx Plastic Zy Torsional J As-xx Def As-yy Def As-�c Stress As-yy Stress = General = Arbitrary = 6 = 1.861 = 2.872 = 1.870 = 0.839 = 0.931 = 0.931 = 1.435 = 1.437 = 2.531 = 0.866 = 1.083 = 0.273 = 0.000 = 0.754 = 0.753 = 0.293 = 0.293 = 1.118 = 0.561 = 0.919 = 0.468 = 0.006 = 1.000 = 1.000 = 1.000 = 1.000 in^2 in^4 in^4 in^4 in^3 in^3 in^3 in^3 in in in^3 in^3 in^4 Section Diagram C:\RISA Section Files\GONDOLA-NEW.nmsx - B8 0 APPENDIX C ANCHOR BOLT DESIGN & ICC ESR-3027 REPORT ,loB: � g279 DATE: 07/07/16 JOE P. HILL, P.E. BY: Cp CH�: JPH CONSULTING STRUCTURAL ENGINEERING 1801 N. HAMPTON RD., SUITE 440 DESOTO, TX 75115-2399 972-283-5111 E-Mail:Joe@jphpe.com C� ANCHOR BOLT DESIGN FOR WIDE SPAN SHELVING: MAX. MAX. FRAME SHEAR UPLIFT (LBS.) (LBS.) E1 137 635 FACTORED LOADS MAX. SHEAR (LBS.) 137 198 ANCHORS: MAX. UPLIFT (LBS.) 635 915 USE TWO (2) 3/8" DIA. HILTI KWIK HUS-EZ (KH-EZ) SCREW ANCHOR WITH 2.5" MIN. NOMINAL EMBEDMENT, CARBON STEEL, INSTALLATION PER ESR-3027. SEE NEXT PAGES FOR CALCS. CZ www.niiti.us Profis Anchor 2.6.5 Company: JOE P. HILL,P.E.,INC Page: 1 Specifier: CD Project: BURLINGTON Address: 1801 N. HAMPTON ROAD, SUITE 440,DESOTO,TX Sub-Project I Pos. No.: WS Phone I Fax: 972-283-5111 � 972-283-5113 Date: 7/8/2016 E-Mail: Specifier's comments: 1 Input data � Anchor type and diameter: KWIK HUS-EZ (KH-EZ) 3/8 (21/2) � Effective embedment depth: her,ea = 1.860 in., hnom = 2•500 III. Material: Carbon Steel Evaluation Service Report: ESR-3027 � Issued I Valid: 12/1/2015 � 12/1/2017 Proof: Design method ACI 318-11 / Mech. Stand-off installation: eb = 0.000 in. (no stand-of�; t= 0.108 in. Anchor plate: Ix x ly x t= 2.250 in. x 4.250 in. x 0.108 in.; (Recommended plate thickness: not calculated Profile: no profile Base material: Installation: Reinforcement: Seismic loads (cat. C, D, E, or F) Geometry [in.] & Loading [Ib, in.lb] cracked concrete, 2500, f� = 2500 psi; h= 4.000 in. hammer drilled hole, Installation condition: Dry tension: condition B, shear: condition B; no supplemental splitting reinforcement present edge reinforcement: none or < No. 4 bar Tension load: yes (D.3.3.4.3 (d)) Shear load: yes (D.3.3.5.3 (c)) y.. Input data and results must be checked for agreement with the existing wndi6ons and for plausibility! �'] PROFIS Anchor ( c) 200�2009 Hilti AG, FL-9494 Schaan Hilli is a registered Trademark of Hilti AG, Schaan J www.hilti.us Company: JOE P. HILL,P.E.,INC Page: Specifier: CD Project: Address: 1801 N. HAMPTON ROAD, SUITE 440,DESOTO,TX Sub-Project I Pos. No.: Phone I Fax: 972-283-5111 � 972-283-5113 Date: E-Mail: 2 Load case/Resulting anchor forces Load case: Design loads Anchor reactions [Ib] Tension force: (+Tension, -Compression) Anchor Tension force Shear force Shear force x Shear force y 1 519 99 99 0 2 519 99 99 0 max. concrete compressive strain: 0.06 [°/oo] max. concrete compressive stress: 260 [psi] resulting tension force in (x/y)=(0.125/0.000): 1039 [Ib] resulting compression force in (x/y)=(1.051/0.000): 124 (Ib] 3 Tension load Profis Anchor 2.6.5 2 BURLINGTON WS 7/8/2016 Load N1e Ilb] Capacity �N„ [Ib] Utilization �= N„�/+N„ Status Steel Strength` 519 6718 8 OK Pullout Strength" Concrete Breakout Strength'* N/A 1039 * anchor having the highest loading "anchor group (anchors in tension) 3.1 Steel Strength Nsa = ESR value refer to ICC-ES ESR-3027 � Nsa Z Nua ACI 318-11 TBble D.4.1.1 Variables A58,N Iin.21 futa �PS�� 0.09 120300 Calculations Nsa I�b� 10335 N/A 1569 Results Nsa ��b� �steet �nondud�ie � Nsa ��b� Nua ��b� 10335 0.650 1.000 6718 519 N/A N/A 67 OK Input data and results must be checked for agreement with the existing conditions and for plausibility! /'+ ^ PROFIS Anchor ( c) 2003-2009 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan \�`'f www.nilti.us Company: JOE P. HILL,P.E.,INC Page: Specifier: CD Project: Address: 1801 N. HAMPTON ROAD, SUITE 440,DESOTO,TX Sub-Project I Pos. No. Phone I Fax: 972-283-5111 � 972-283-5113 Date: E-Mail: 3.2 Concrete Breakout Strength Ncbg —(A o� �/ec,N Wed.N IVe.N WcP.N Nb � N�9 2 Nua AN� see ACI 318-11, Part D.5.2.1, Fig. RD.5.2.1(b) z ANco - 9 het 1 41e�,N �+ 2 eN) <_ 1.0 3 het/ y/ed.N = 0.7 + 0.3 � �a.min l � 1.0 1.5hef/ W�P,N = MAX �a=min 1.5he� � 1.0 � �ac � �ac � Nb =kcaa�he'ts ACI 318-11 Eq. (D-4) ACI 318-11 Table D.4.1.1 ACI 318-11 Eq. (D-5) ACI 318-11 Eq. (D-8) ACI 318-11 Eq. (D-10) ACI 318-11 Eq. (D-12) ACI 318-11 Eq. (D-6) Variables het Ilfl.] e�,.N [in.1 e�z.N Iin.] Ca.min tlfl.l y1c N 1.860 0.000 0.000 � 1.000 �ac ��I1.� kc aa fc �ps�� 2.920 17 1.000 2500 Profis Anchor 2.6.5 3 BURLINGTON WS 7/8/2016 Calculations ^Nc lln.2J AN�o I�� ZI ylecl,N wec2,N �Ved,N WcP.N Nu I�bl 46.48 31.14 1.000 1.000 1.000 1.000 2156 Results N�n9 I�bl �concrete �seismic �nondudiie � Ncbg LIb� N�a [�b] 3219 0.650 0.750 1.000 1569 1039 Input data and results must be checked for agreement with the existing conditions and far plausibility! n e PROFIS Anchor ( c) 2003-2009 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan �.�v W1NW.f11�tI.US Company: JOE P. HILL,P.E.,INC Page: Specifier: CD Project: Address: 1801 N. HAMPTON ROAD, SUITE 440,DESOTO,TX Sub-Project I Pos. No.: Phone I Fax: 972-283-5111 � 972-283-5113 Date: E-Mail: 4 Shear load � III Profis Anchor 2.6.5 4 BURLINGTON WS 7/8/2016 Load V,,, [Ib] Capacity �V� [Ib] UtIIiZ8t1011 �y = V�a/+Vn Status Steel Strength` 99 1867 6 OK Steel failure (with lever arm)* N/A N/A N/A N/A Pryout Strength'* 198 2253 9 OK Concrete edge failure in direction `* N/A N/A N/A N/A ' anchor having the highest loading **anchor group (relevant anchors) 4.1 Steel Strength VSe,eQ = ESR value refer to ICC-ES ESR-3027 � Vs,�i Z V�a ACI 318-11 Table D.4.1.1 Variables Ase.v Un?I futa �PS�� 0.09 120300 Calculations Vsa ey [Ib] 3111 Results Vsa,eq I�b� �steel �nondudile � Vse [�b] Vua [�b] 3111 0.600 1.000 1867 99 4.2 Pryout Strength V�P9 — k�P L\/�NcO� Wec.N 1�ed.N y1c,N ylcp,N NbJ � Vcpg Z Vua AN� see ACI 318-11, Part D.5.2.1, Fig. RD.5.2.1(b) z ��o = 9 her 1 we� N �+ 2 eN 5 1.0 _ � 3 hef Wad,N = 0.7 + 0.3 ( Ca.min 1 c 1.0 1.5h8�/ t�/cp N= MAX �a=min 1.5het � 1.0 � Cac � Cac � Nb = kc �a `�1C hef AC1318-11 Eq.(D-41) ACI 318-11 Table D.4.1.1 ACI 318-11 Eq. (D-5) ACI 318-11 Eq. (D-8) ACI 318-11 Eq. (D-10) ACI 318-11 Eq. (D-12) ACI 318-11 Eq. (D-6) Variables kcp hef �Ifl.� eci,N �Ifl.� ec2,N �III.� Ca.min �III.� 1 1.860 0.000 0.000 ^� tVc,N Cac [Il1.] k� Ra fc �PS�� 1.000 2.920 17 1.000 2500 Calculations �� f �?1 AN�o I�n?l y�aci,N weo2 N yled N W�P.N Nn I�bl 46.48 31.14 1.000 1.000 1.000 1.000 2156 Results V�P9 �II)� �concrete �seismic �nonduaile � V�Py �Ib� �/Ue [�b] 3219 0.700 1.000 1.000 2253 198 Input data and results must be checked for agreement with the existing conditions and for plausibility! /'�G PROFIS Anchor ( c) 2003-2009 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan �•� V www.nilti.us Company: JOE P. HILL,P.E.,INC Page: Specifier: CD Project: Address: 1801 N. HAMPTON ROAD, SUITE 440,DESOTO,TX Sub-Project I Pos. No. Phone I Fax: 972-283-5111 � 972-283-5113 Date: E-Mail: 5 Combined tension and shear loads Profis Anchor 2.6.5 5 BURLINGTON WS 7/8/2016 Rr, pv � Utilization RN v[%] Status 0.662 0.088 5/3 53 OK Rr�v = (3� + (3v <= 1 6 Warnings • Load re-distributions on the anchors due to elastic deformations of the anchor plate are not considered. The anchor plate is assumed to be sufficiently stiff, in order not to be deformed when subjected to the loading! Input data and results must be checked for agreement with the existing conditions and for plausibility! • Condition A applies when supplementary reinforcement is used. The m factor is increased for non-steel Design Strengths except Pullout Strength and Pryout strength. Condition B applies when supplementary reinforcement is not used and for Pullout Strength and Pryout Strength. Refer to your local standard. • Refer to the manufacturer's product literature for cleaning and installation instructions. • Checking the transfer of loads into the base material and the shear resistance are required in accordance with ACI 318 or the relevant standard! • An anchor design approach for structures assigned to Seismic Design Category C, D, E or F is given in ACI 318-11 Appendix D, Part D.3.3.4.3 (a) that requires the governing design strength of an anchor or group of anchors be limited by ductile steel failure. If this is NOT the case, the connection design (tension) shall satisTy the provisions of Part D.3.3.4.3 (b), Part D.3.3.4.3 (c), or Part D.3.3.4.3 (d). The connection design (shear) shall satisfy the provisions of Part D.3.3.5.3 (a), Part D.3.3.5.3 (b), or Part D.3.3.5.3 (c). • Part D.3.3.4.3 (b) / part D.3.3.5.3 (a) require the attachment the anchors are connecting to the structure be designed to undergo ductile yielding at a load level corresponding to anchor forces no greater than the controlling design strength. Part D.3.3.4.3 (c) / part D.3.3.5.3 (b) waive the ductility requirements and require the anchors to be designed for the maximum tension / shear that can be transmitted to the anchors by a non-yielding attachment. Part D.3.3.4.3 (d) / part D.3.3.5.3 (c) waive the ductility requirements and require the design strength of the anchors to equal or exceed the maximum tension / shear obtained from design load combinations that include E, with E increased by �o. • Hilti post-installed anchors shall be installed in accordance with the Hilti Manufacturer's Printed Installation Instructions (MPII). Reference ACI 318-11, Part D.9.1 Fastening meets the design criteria! Input data and results must be checked for agreement with the existing conditions and for plausibilityl /�+� PROFIS Anchor ( c) 2003-2009 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan t� � � . �. �� DIVlSIQN: 03 00 00--CONCRETE SECT{ON: 0316 00--CONCRETf ANCHORS �IVISION: 05 QO 00—METALS SfCiION: 05 0519—POST-INSTAIED CONCR�7'E ANCHORS �tEPORT HOI,DER: HILTI, INC. 7Z50 DALLAS PARKWAY, SUITE 1000 PLANO, T€XAS ?5024 EVAU7ATfOAI SUQiEC7: �iI�T! K1NIK HUS-EZ {KH-EZj AND KWIK HUS-EZ I{KH-EZ i) CAR80�U STEEL SCR�W ANCHORS fOR USE !N CRACKED AND UNCR�CICED CC)NCR�TE ICC ��� , ICC ���� ���� 1�� c PMG � IISTElJ Look for the trusted marks af Conformity! "2D24 Recipient of �restigiaus Western Siates Seismic Policy Council (WSSPC} Award in Farcellence" A Subsidiary of ICC ES Ei�ahration Reports are �ro11n be cons,trued as ,representing aesthetics or any other Qttrihu�es nai /� 1 "`"ri°'"' spec�cally addressed, nor are lb�ey �o be Consd�ued as an endorseme�rt of the subject of the repor! ar a�� �� i�ecomme»dat�on J'or its use. T?1e�•e is no wan•an�j� by ICC Evaluatror� Sen�ice, LLG exp�ess or inrp1ied, as � to a�ry findrng or ot)ter matter i►� �hrs report, or rrs ta nny prdduct co>>ered �y fhe repo��, � � +�,..�r «� Gopyrigh# � 2U151CC Evaluation Service, LLC All rights resenred. C$ ICCeES '�vafuaiEora Report ESR-3027 l2eissued December 2015 �'�is report is subject to renewa! December 2017, vvww.icc-�s.orq �{SOOj 4�3-658i ;� (562) 699-0543 A Subsidiary of the Internafional Code Council� D[VIStON: 03 00 OO�CONCRETE Sectlon: 0316 '00--Concrete .Anchors DN1510N: 05 00 00-METALS 8ection: OS 0519--�ost-lnstalled Concrete Anchors REPORT ^HOI:DER: #IILTE, INC.. ''7254 DALLAS PA'RKWAY,'SUITE 900D PL,ANO; t�XAS 75024 (80Q}879-8000 � � www.us.hilt�.com �'�Hi ItiTech Er�q Caaus.'h'itfi:com EVALUA'TION SUBJECT: HILTi KWIK HUS-EZ (K1#-EZj AI�D iKWIK �il�S-�Z'd. {KH-EZ 1,) CARBOI�f STEEL SCREIM1iANCfiORS!�DR USE fN CR;4CKED AND UNCRACKED CONCRfTE 1.0 EV/1LUiATiON SCOPE 'Compliance with the followi�g codes:. • 2015,�7012,•2009, and 20061nfern8tional8uilding �Code�' (IBC) :■ 2015, 2012, 2009, and 2006 Irifemationa! Re'.srdential Gode�:(fRC) � � 201'3 Abu Dhatii'Infemati.ona1 Build�ng:Code (A'DIBC,)t tThe ADIBC is based oii ll�e'2U091�G. 2009 IBC code atctions reteienced'In . - fhis mport arc fhe same sections in the ADIBd. ";Property evaluatedt SWctufal. 2:0: �USES The Hitti KIMK HUS-EZ (KH-EZ) screinr anchors are �ased to resist static, wind and seismic .tension and shea� loads in cracked and uncracked normai-we3ght and sa�d-lighiweigtit cbncrete having a specified. strength, .1'�: of ;2;500 �si :to. 8;500' .psi (97.2 MPa to. 58.6 1WIPa); :and cracked and uncracked normaFweight or sand-lightweight concrete aver steel deck having a mi�imum :specified c:ompressive strength, f�, of 3,000 psi (2D.7 MPa) iminimum •of 24 MPa is reguired under.ADIBC Append'ix L, Section 5.1.1j: The K1MK HUS-EZ !(KH-EZ I) screw anchors are used tb resist static, wind and seismic;tension and shear loads onty in cradted and uncradced -normal-weight and sand- �lightweight wncrete having a specified strength, 'i'�, af 2;500 psi to 8,500 psi (97:2 MPa 'to 58:6 MPa); and cradced and uncraciced normai-weight ar sand-lighiweighi .concrete aver steel.deck havirig a minimum:specified coinpressive 'strength, .P�, of 3;000-�isi (20.7'MPa) [min'�mum of 2A MPa is required u�der ADIBC Appendix I., Section 5.1 1]. 7t�e :Hitti. KiMK HUS-E� (KH-EY) and KVYIK FlliS-E�Z I (1CH-EZ i) screw ancho�s are an afternative to ancho�s described �in Section '1901.3 of 3he 2015 IBC, Sectioms 1908 and 1809 of the 2012 IBC, Sections 1911 'and 1912 of the 2009 :and 20q6.IBC. The anchors may also be used where ara engineered. design is submitted in accordance with 5ection R301.1;3 of the �IRC.. 3:0 'QESC'RIPTION 3.1 KIMK NUS,EZ (KH-EZ): Hilti KWIK HUS=EZ ;(KM-EZj anct►ors are comprised of a body with hex washe�'head.:'fhe anchor is manutaet►�red #rom carbon steel -and ,is ;heat=treated.. tf �as a minimum 0:0003-inch-thick ;�8 Ntnj .z'inc. coating in accflrdance with OIN EN IS0 4Q42: 'The anchoring system is available in a va�iety of lengths,. with nominal diamefers of 'Ja '•inch, 3I8 "IhCFd, �/2 IIiCFI,.`5/a inct� and '�1a, inch: A typical }CIMK fil9S-EZ (ICIi-�EZ) tis illustrated in �igure 2. The taex head `is .larger'than the diameter of the ar�chor �and ss iormed with ser�ations on ihe underside. The aiachor body is forrned witfi threads:running most of the leng'th of the anchor body. The anchor:is installed in a predrilled hole with a;powered '+mpaci wFench or °torque wrench. The -anchor 3hr+eads cut"into the concrete on the sides. of the `hole . , . and ,interlock with the base matenal during ins�allation. `3.2 K1MK HUS-EZ 1;(KH-� il): The •KIMK HUS=EZ I(KH-EZ:I) anchors aie comprised of a :body -with. a long intemally ihreaded ('la,inch o� 3/8. inch `intemal th�ead) �hex w8shei head: The ancho� is manufactured frorri'carbon steel and is tieat-treated: It.has a �minimum U.0003=inch=thick.:(8 ,;Niti) .zinc coafing in accordance with pIN EN �S0.:4042: 'The anchoring system ,is available in two lengths and a nominal diameter of 'ta'inch. A typical:K1MK hiUS�Z I{KH-�Z I) is'illust�ated in �Figure 3. The oVer-s'ized hex head is larger than the diameter of the anchor and ;is formed with serrabons on ihe unde�side. The snchor body is formed with ,tFaraads .cunning most .of the �length...of the a�achor- �boify: The anchor is ins'talled 'in a' ,;predrilled hole with a�powered ;impact wrench or ;torque wrench direcily 3o fhe supporting, 'member surhace. The anchor threads cut inio the concrete on the sides ofithe hole °and ir�terlock with the base maferial duri�g installation. Shear design vslues in this fepoif'for the K1MK HUS EZ I {�CM-E,Z.1) are for threaded inseris witta f,; equal to:or greater �lian 125 Iksi. �or use'with inseRs with .F„ �ess dhan 125.icsi, lCGES EimluDiton Rej�orxs vie not ro b@'eonstruirl ns n�senri�g iicsthrttc,s or nny oihtr ortrib+itts ncfaptelficnlfy addr¢siPd nor dre rhey to be rbnstrueif ' � as an endorsr�ntnf pfthr 3ubJecY Oftht��Yr.porl or n-r�rOmm�ndallon jor tLt �ae Thrrc�la rro i±nrrttnp�.bti 1CG E�mliurrion Servlce LLC. �c�press a• impl�ed ar � to d'ey;pna'frtg oPo�hrr mauer in this report, aras fo an�� produel co�rred.'bv rhe.r�rt., ���� Gopynght O`.20151CG Evaluation Service; LLC: .AB righfs-►eserved.. Pago 1 oi 14 C9 ESFi•3Q27 J Most �deJy Accepted end Trusted Page 2 of 14 the shear values are multiplied by ¢he ratio of 'F„ of insert antl 125 ksi. 3:3 Concrete: Normal-weight and sand-lightweight concrete must conform fo Sectiori"s 1903 and 1905 of #he IBC. 3.4 Stee'I Deck Ranels: Steel deck panels ;mu"st comply with the confgucations in Figu�e 5 and have e minimum base steel thickness of 0.035 .inch ;{p.889 mm). :SteeF .must •comply wiih ASTM A653fA653M.. SS Grade 33 and have a-minimum yaeid strer�gth of 33,000 ps`i (228 MPa). ,.4:0 'DESIGN l4ND INSTALI.ATION ;4.1 5tre�igth Design: � 9;a �General:.Qesign.�strength:of anchors complying with `the 2015 IBC, as:well as Section R301.1,3 of the 2035 I�C �must 6e;'deteimined in accordance with ACf '318-i4 Ghapter 17 and this report.: �Design st�ngih,of anchors complyir�g with tt�e' 2U12 19C �as well ss Sec6on R30'1 a.3 of the 2012. :IRC must be 'determined in accordance witti ACl �318-11 ��ppendix D arid :ttiis report: Design sirength �of anc'hors complying with the 2009 IBC and Section R301 1.3'of the '2U09 IRC musi be :detem�ined in accordance`with ,lcC) 31�8-08 Appendix D and ihis repo�t. Design stre�gth of anchors complylr�g with the 2006 fBC and 20Q6 IRC must be: iir� :accordance with ACI -3�8-05' Appentlix D and Utis reporL Design parametecs, provided,in Table:2 ,through Table 7, of this �eport aTe based :on xhe 3095' IBG (AC! 31&i4) and :2092 -IBC (AGI 31&11) unless ,noteiJ otherwise ir� Sections =4'1:1 through�a.1:32. ihe stn'ength design :of an.chois �musf comp'ly v✓ith AC{ 31&14;•17.3:7 orACl 318-11 �.4.1, as applicable, except'ss, required in AC� �318-14 17:2.3 or ACI `39&1 ti.D'.3.3, as ;applicable . �SUength reduction,'facto�s; �, as :given in A�1 �31&14 17:3.3 or .ACI 338=11 D:4.3, as ,applicable, and ;nated in Tables 3'.and 4 of:this �epo�t, must be used for7oad �combinations ;catc�i'fated in accoMance wittt ,Section 1605,2 �of the IBG and Secdon�5:3 of ACI,`398=i4 or Section :9:2 of ,ACI'31&97, as applicable. StrengtFi reducfion factors, �; as given in A'CI �31&11 D�4:4 must, be ;used ;for load combinations calculated 'in � accordance ��with A�'1 318-11 �Appendix<C., ihe`value�of f�.used in the calc�alations:must;be limited to• a maximum of 8;OQp psi {55.2 MPa),�in ar,cordance with ACI `31&�i4. 17:2.7 or ACI 3i8-11 ID.3.7, �as ;spplicabte. ,An. example calculation. �in ac�orHance iivifh the.2015 and 2012 fBC is proyided :in Figure 6. '4.1.� �tequiremen4s for �tatic .Steel Strength in fiension, N�:'The nominal static :sfeel strength, N�, �of a' single anchor in �ension calculated in accordance with ACI. ,318-14 1Z4.1.2:,o'r ACI 31�i1 D.5:1:2, as .applicable, is grven.`in Taple 3 of this teport. .5trength reduction, facto�s,q, corresponding to''br�ttle steel elemenEs mus4lse used: 4.1.3 Requlrement8 :for Static Conorete Breakout Sh+ength in 7ension, N,� o'r.. N��t The nominal concrete. breakout strength'of a single anchor or a group'of anchors in.tension, N� and N�,,res.pective'ly, �must be calculated'�n 'accordance with ACI 318=;14 .`I7.4:2 or ACI 318-11 0:5.2, a5 applicabie, wifh rnodifications as described in this section. The' basic concrete breakout .suength of a single anchor `in ten"si�n; Nb. must be"cafculated �n eccordance with 'AC# 39'8- 14 17,A:2.2 or AGI•318-1/ D53.'2, as-applicabte; using fiie :values of. �ie, snd �k� as rgiven in �ables 3;and .7 of. th'is repor�. The nominal �;oncrete breakoutstrength in tension in �egions where analysis �ndicates no cracking in accorrlance with ACf 3'18-a4 'l7:4:2.6 or •ACI 31'8-'11 :D.5.2:6, as applicable„ must be r.�fculated wiEh the valae of k,,,,� as given in Tabie 3 and virith,�y,v 1:0. �or anchors installed in the lower �or upper flute of 3he soffit of :sand-li.ghtweight ;or normal-weight concrete-filled steel deck floor and. roof assemblies, as s'howm,.in Figure 5, calcutatioro of the concrete �reakout sfrength in a'ccordance with ACI 318&14 17A.2 or ACl 3a8-11 D.5.2, as app9icable, is nof�requited. 4.1:d _ Requirements for . Static Pultouf Strength in Tansion; Np: 'fhe r�ominal :pulfout strength of a single anchor �in accordance with AC1318-1417.4:3.1 and 17:4.3.2 or AGI'3i&i i D.5:3.1 and D.5.3.2, as applicable, in cracked and �uricradced concrete, ,Np,�,, and Np;,,,,�, respectively, is given in T.able '3. In lieu of ACI 318-14 17:4.3:6 ar ACI .318- � 1 D:5:3.6, as applicable, wu� _�:0 fior a11 design ca5es.11n accoManoe rvith ACI 318-14 17.a.3 or_ACi 318=11 D.5.3� as applicable, the •nomir�al p�tllout strength nn cracked concrete may be adjusted •accortliqg to Eq.=1: !11 , � � /�1 l� " .rf� ns,.�z,sou� {Ib, psi) (Eq-1j �p;J� ��Nn,n- lz�zln ��1, MPe) where'f� is tFie specified.conc�ete compressive strength and n:is the '.factor defining ,the' influence of concrete �ompressive strengtY� � on the pullout str�ength. For fhe �7e-inch�iameter anchor �at 15/e inches mm�inal embedment in cracked concrete, n'is 0.3.,For all other cases; n is U:S: in +regions wher�e 'analysis : indicates �no crackir�g in accor�danoe with .AC) 31&14' i7.4`3:6 :o� �ACI 318=11 D,�.3,6, as applicable; the nominai ,putlout strengfh 'in. tension may tie adjusted according to Eg 2:. Nn.f� =:Ny,,,�� (' r , �c �Ib psil ��q-2.) lxSoo�, �,� 'IVy;f� _.Nn�vner l��.z� �N, MPaj �where i'�'d"s the s`pecifled 'concrete compressive s�rength and n�s the fector d'efining the influenoe of concfete compressive ::strength :on the ;pullout sfrength. For the �/c-inch-diame'ter anchor at a nominal embedment of 1�fe 6nches in uncFa�ed ��nctete, n�s fl.3. For'all other cases, ,n'is 0.°5. VNhere'values fior Np,drOf Np,,,,,n are not proVided in Table 3 of 'this report; the �ullout �strength in tension need not .be, �cflnsidered: The nominat pulfout: strength in tenSion .of the anchors ;ir�stalled i� the soffit of sand-lightweight or normal-weight ¢oncrete filled �steef :dedc floor and roof assemblies, as sfiown 'in �igure 5, 'is provided in 'Table 5.for 'K1NIK FIUS=E2 and Tabte 6,for K1MK FiUS-'E2 I. In accordance with ACI 31&14 iZ4.3:2 or' ACI..31&11 D.53.2, .as applicable, the nominal puflout strengtti in cracked concrefe must be ca{culated aceording to �Eq-1, wtiereby ihe value af Np;o�w�,o must 'tie substituted for �IP,�, and tt�e value of 3,000 psi {20.7 MPa) =must be subsfituted for the value of 2;500 psi (17.2.MP,a) in 3he denominator. 'fn regions where. analysis indieates no crackin,g in accordancg with ACI `31& 94 17.4,3.6 or A'CI 318-11 5.3:6, aS applicable„ the nominal 'strength in uncradced concrete :must be cafculated according to ;Eq-2, whereby the.value of NP,�,,,,,,� �nust be substituted for 1Vp,�;,�, and the value •of 3,000 psi r(20.7 MPa) 'mu�t be �substituted �for the'ya9ue of 2;500 psi (1�7;2.MPa) in. the denominatar: � a.1.6 Requlrements foc Stattc ; Steei 5hear � Capacity., V�: The morninal steel strength in shear, V�, �of a single: ;anchor �in,ac�orrlance with.AC131Fi-14 17.5:9.2 or AC1 33& C� O ESR-30�7 I Mos1 Widely:Accepied and Trusted Page. 3 of 94. 'I'1 D:6:1.2, as applicable rs given in Table 4 ofi this report and must be usetl'�n lieu of tlie values derived by.cafculation #rom ACf .318=14 Eq. 97.5.1,2b or AC� 31&11 �q. D-29, as applicable, The strength feduction f8ctor,� correspontling to. .britde steel eiemenis must :be used. The nomihal shear <shength V�,�; of:anchors installed in:;he:soffit oi�sand- lightweight or norinal�weight concrele filled steel deck floor �and roof assemblies, as sMown in Figure �, is given'�n �able 5 for K1MK HUS-EZ and 7able S, for KVUIK HUS-EZ I; SheaP values. fo� �K1MK HUS-EZ I�(K�H-EZ 1) .are for threaded inserts' anth 'Fu �z 125 ksi. `I�or use with inserts with �„ iess than 725 ksi,:#he shea� values are;muftiplied by the r�tio of F„ of inse�t and 125`ksi: 4:1;$ Requirements for Statia Concrete �reakout Sfrength in :Shear; 1/ b flc V�,yy: The nominal concrete bieakout strength of a single' anchor or group .of anctiors 'ir� shear V� or V�, respecEi�ely, must be �calcul8ted �n ;accardance with AC� 318=14'�7:5.2 or ACI 318.'J1 D:6.2, as °appficable., with. modifications as ,desccibed in 'fhis section. `The basic concrete breakout,strength in •stiear, Vb; rriust be. �calculated in taccordence with i4C�.318-14 17.5.2,2 or ACI :3'18-1'i D.6.2:2, as appficable, "using the �values �of :�, and :d8 {doj given in Tabte 4. For anchors: installe8 :in #he tower ot upper flute, of the soffit of santi :ligFihveight or norrrial-weig'ht ooAcrete=filled steel deck :floor;and roof assemblies, as.shown in Figure 5, calculation of the concrete. breakout strength in �accordance Gvifh ACl 31&14 17;5.2 or ACl 318-11 '�.6'2 is nof required.. 4.1.7 Requi►ements for .Static., Concrete �Pryout <Strength in �Shear, �V�, or V�„�: The <nominal cflncrete� ;pryout strength of,a singie anchor ior group'of•anchors,� V�; or V�, respectivefy, must .be calculated ;in'accordance with :ACI 31&14 17.5:3 or ACI ;31&'7'� p:6 3; as�8pplicable using 3he coefficient fbr pryout:strength, '.km provided :iri;�abEe ;�• and the va9ue of N�, o� N� as calculateii in `Section•4.1,3 of' 'this report. � _ _.. .. __ For anchors installed in the �,iower or up�ier 'flufe "af: the ;soffit of .sand-ligfitweight or no�nal weigfit concrete-filled. ;steel dec4c floor:and �oof asse�ibfies, as'•shown:in ��igure 5;-. ;calculation of the :concrete pryout: sU�ength in ,,accordaroce iNith ACI 318-1417:5.3 0� AG1318=11 D.6:3 is not "required: • 4.�;8 Regufrements f"or Seismic Design: d.7:8.1 General; For loatl .cotiabinations 'including :seismic; ttie design must tie 'in accordance with ACI 318=14,a7.2.3 or AG9 ,318-91 �.3.3; as:appficable..Modi6cations to,ACl�318& `14: �7.2,3 shall be applied under �Section 1905.1:8 or� the 20]5 �'IBG: For'the 2012 1BC, Section i905;1:9�:sfiatl be omitted. Mod�fiCations fo AC� 31$ �(-08, �-05) :D 3:3 shall be. applietl under' Section 1908.1.9 of the 2009. IBC, or'Section 1908.1:16 ofthe 2006 IBC,�as applicable. The ;anchors comply .v�iith :ACI 31&14 -2.3 or ACi 348-19. D;1, as appticable, as brittle steel elements and must be designed 'in 'accordan'ce with ACI 318.-14 17:2:3 4 ot i 7:2 3 5, AC1318-� 9 D.3.3.4 ar D.3,3 5; ACI 31$-08 D 3_3.5 or D.'3;3.6;' or ACI 318-05 �D.3.3.5, as applicabte. �4.1.8.2 �Seismie Tension: The no..minal steel:strength and noriminal concrete 'breaKout strength, #or anchors in tension must be calculated.in accorda�ace with ACI 398=�4 �,7:4:1 and 17.4.2 or ACI 318=11 D.�.1 and �.5.2, respectiVel,y, as app1icable, as des�ri6ed :in Sectio»s 4.1:2'and 4.1,3 oi this .rePort. In accordancQ with.ACl 318-1d 17:4:3.2 or ACI 31& a 7 D.5.3.2; as applii�ble, ihe appropnafe value''for;pullout strength ;in tension 'for seismic loads; NP�.:o'r ;N���;Q described'in i'ables,3 and 5 for KWIK HUS-EZ;•respective1y; and in Tables`"3.and ;6, fo.r K1MK HUS-�Z l,. respectively; rhust be used +n lieu of Np. NpeQ or Np�;a:may be adjusted .'by` �calcu'lations for ,concrete compcessiJe shength�� an accord8nce witti �q-1 of this �eport_ in addition foT concrete= 'filled steel deck floor. and toof asse�blies the value of 3,000 psi {20.7'iMPa) must be substituted tor the vafue of 2,500 psi (17.2 MP.a) �in the. denominator. Where values for Np,� are not provided in Table 3 of this report, the .�pullout strength in iension for seisrr�ic�lqads need not be eValuated. 4.9:8.3 Selsmic 'Shear:'The nominal concrete brea'kout sUeng'th and pryout.sirength in shear.must be calculated in accordance.witt� ACf 31&:94 17'S.2 and ��7.5.3 orACl 33&: 19 D:6.2 and D:6.3, ,.respectively, as appficable,. ;�as :descnbed in Sec�ions �,1,:6. and 4:1:7 of this report. ..fn accordance with ACi 318-�4 1 i:5..1:2: or AC1318-11. D.8:1:2, as applicab1e,,. the �appropnate value far �ominal steel ;strength fpr Seismic lloads; �!�;� : or 'V�,da�,�� �describ�d in 'fables' 4 and 5#or KW1K IiUS-EZ, respectively; and in 'fables 4 a�d 6.for KIMK HUS-EZ I, :respec6vely, �must be used ir� lieu o%'V�, � 4.1:9 .Requiremenls fo� In`teraction . of Tensfle .and ,�liear Fn�es: For anchors'or groups of anchors thaf are subject to the effects ;at cflmbined tensile and shear forces, tFie design must be;deteimined in accordarace with ACI 318- 14 i,7.6 or ACl 31&19 D;7,:as appGcabie: d 1:10 Requirements for Minimum Membet Thickness,, Minlmum.Anchor Spacing and Minlmum I�dge Distance: In lieu ofAGI 3�&14 1�.7.� and 17.7:3 orACl �316&9i Ds8.i and D.8.3; as �applicable; values of s;�„ and c,�;,,. �respectively, as give'n in Table 2 of this report must�be used. In` lieu �of ACI 318-94 '17:7:5. or 'ACl :318-11 D.8;�; as applicable, mimmuin �inember thicknesses; hm„ as ,giVen in Table 2 musf be used. Add'itional.combinations �C+r minimum �edge distance, c„�;,,�:and ininimurri spacing distance, s,�;,, �nay be derived by �linear interpotation 'between the .given •tioundary values as defined in iabte 2 of ttiis report. 'For ancho�s ►rasfa'tled ;ihrough `ttie sofifit .of steel deck :assemblies, fhe anchors must be installed in accordance �with 1Figure 5 and shall have. an axial.spacing along;the flufe: �egua) to the,gteater of 3hei or 1.5 times the flute width, F.or J�-1r1CFi 8Tld s/�i�OCh °.#CWIK H115=�Z�(ICF#-EZ� ari611or5 insfaUed on' the top of steel deck' -assembfies, .values .'of ce�;w�,,o�, s,�,;,�,�; and c,�,,,ae�xiop, as given'in 7able 7 of `this repoRt»ust;be usecl, � � 4.1:1'1 �Requirements fo'r'.C�itical �dge: ;Distance, c,�: ,In applicaUons where c•< cec and supplemental reinforcement. to oontrol,. splitting of ,the conc'refe `�is not; present, :the coricrete breakout . strengt#i i� tensibn for uncracked •concrete, calcufated in aocordance with,ACl.318-14 17.4.2 or .ACI 31&11 D.5:2, :as .applicable, must be farther °�u�iplied by the 'factor ��,,u as 'given by ;Eq=3: c. ��P.N= �� ��Q'�� viiFiere the ;factor w�,N need �not �be taken as leSs ihan �.5��. �or a11 other cases: 4��,,N 1:0. In lieu �of using ACi, ,�� � - 31&14 17.7:6 or ACI 3a&11 D.8,6, as applicable, yalues of c� m'ust �mplyw+th Tabfes 3 and 7. 4.1.12' Sand-lightweight. Concrete: For ACI 318-.14 (20'15 j�BC), ACI 318-11 {2Di2 IBC) and' ACI 318-08 (2009 IBC), when;anchors'ate :used in sand-liglitweight concrete; the modification :factor for concrefe breakout, �, :or l�, re'spectively, must be iaken as 0.6 . in Iie .0 � of ,ACI :318=� 4 17.2.6 {2095..IBC), ACI'3a8-�i D<3.6 (2012 �IBC),or,ACl,318- 8 f3:3.4;(20U9 IBCj...ln addition, the pullout strength �Jn;,;,;�, 'Np,p, and Np,eQ must be multiplied by 0;6; as appYic86fe. .For ACI 318-05 (2006 IBCj., ihe yalues `N�, r1lp��p, Np,�;.. Npeq, and i%b deterinined in;acoordaric� with �Fiis.re,port rriust' be',mutGplied by.0.60; in Iieu.ofACl 318-05 D:3,4: C,� ,� ESR-302? �'Most �delyAccepte.d and ,Trus�ed Pragefi of 74 Fo� anchors in"stalled an the lower or.upper flute of the soffit .of sand-lighfi�reight cancrete-filled steel deck and fioor and. roof assemblles, this �reduction is not requiretl. d.2 Allowa'ble Stress Design (ASD): 4:2.1 ,General: design Vaiues for use wifh aYlowable st�ess design load, :combinations calculafed in acc4rdan�. with �Se�tion 1605.3 of the�;�BC ,inust be established �ising the follovinng equations: Tanowaw�'ASD - �° (E4�) ��� j/811oir8ble.ASD — �a. (�a-5�. where: reno„�,�,aso = �A'llowable tension load {db, Nj V�irowaweAso = A�lowap'le shear load. ��b, N) �,IJ,; = Lowest design strength of an anchor �or anctaor group in tension�as deteRnined in. aocordance wiih ACI 3'18-1a Chapter 17 �and 2015 IBC Section 1905.1:8, ACl 31$- 1�1 Appendix �; ACi 318=08,Appendix D. •and 2009 IBC Section �908.1:9, ACI 318- • 05 Appendix 'D and 2006. (�G Section 1908.1:16, and Section A:1 of ,ttiis report, `as applicabte. �V;, =:Lowest design strength of :an anchor� or. anchor group: in stiear:as determined �in accordance with ACI 3'f8-14 Chapter 17 �and 2015 :IBC Section'1905.1:8, ACI 318= 11 Appendix D, ACi `31'8=08 Appendix .D and 2009'IBC Section '�908:1.9, AC1 '3i8= 05 and 2006 iIBC Section 1908.1.16, anif Section 4.�1;of�this report; as applicable. a = Convetsion factor calculated as :a. weighted average of the load factoi� fo� the ,controfling load. combination. In.. .aiidition., a must include ;alt applicable � iactois •to accounf fo� :nonductile failu're modes and required over-strength. �mits on etlge distance; anchor spacing arid member' thickne"ss as given in'Table 2 of this report must apply.:An eXampfe of Allowable Stress Design #ension values'is ,giVen in Tab'le 8 and �Figu�e 6. � �d.2.2 1nteraction of Tensile •and_ Shear. Forcesc �The ��nteraction:must !�e calculated and consisterot with'ACI 3i& 1417:6 or ACI 318 (-11, -08, -05j D.7,.as follows:. Fo� shear loads VBpp�;ed � 0.21�enowable�lSD� the full',�Ilowable loatl in tension Tari�wa,ASD Sf18II b2 pBRitlrt@d. For tension loads �ep�r�a �.0.2T�c,;,�we;nsr,, ,the fu11 allowable qoad in';sliear Ver�,��,e�+so sfia11 be ;�ermitied. For ell other cases: _tstHN%ed__;{. 'VeADlied <:"i:2 (Eq-S)` .TaQowedareSn Vaoo»�as,Asti 4:3 lnsfallatlon: insta'ilation parameters are provided in Tabtes 1, 2 and 7' and F'igurss �; 4A, 48 and 5. Anchor looation"s must corr�ply with this teport and plaras a"nd speafica�ons approved by the code. official: The !Hilti 1NVIK 41US-EZ (KH-�Zj and iCW1K MUS-F3 1(KH-EZ �I,) must be installed in':acoordance: wifh the manufac#urer's published instruc�#ions, and this report:' In case. of conflict; fhis repor� govemS. A'richois �must be:.installeil.in holes drilled into concrete•perpendicular "fo #he ,surfare� using carbide=2ipped masbnry iJrill bits' ;comprying ;v�nth ANSI 8212.15-1994 :'The. nominal diill_ bit diameter musf be equal to 3h�t of th� anchor. 7Me minimum �dritled hole. depth is given 'in Table 2. .Prior to insiallation; dust and,debris must be removed irom the drulled hole using �a `hand. pump, compres$ed air or a vacuum. The anclio� �must be ins'talled into the prednlled hole using a powered impact virrench or installed wifh a torqwe wirench until the proper nominal embedmeM depth is obtained. The maximum dmpact wrench torq�fe, T�„�a,,,�„ and rraaximum instaltation torque, T'�„�,� 'for ihe 'manual torque wtench :must ;be �in ,ac�ordance with Tab1e 2. The K1MK H115-EZ (K�FII=F2) and KWIK HIJS-�Z I{KH-EZ I} may. be loosened by a �m8ximum of one 1um and �etig'htened'with a torque wrench or powered impact Vvrench to facilitate fixture attachmen't or realignmer►t. Complete removal and reinstalla'Gon of3he .anchor is not allowed: �For 'installabora in the soffit of concrete on steel deck assemblies, the hofe diameier in the sfeel de�lc must not exceed the diameter of the hole in the :coracrete by more 3Me './e inch {3:2 mm): For inember t�aickness antl edge distance restrictions for mstallations into the soffit of conc�ete o� steel deck assemblies, see Figure 5. � For .installatio'n of. �/winch� and 3Le-inch K11VIK �US-EZ "(k�i=EZ) anchors an �the `top of steel d�ck �assemb1ies, see �7abte 7 fo� instailafion setting infirrnation. �4A S�recial:lnspection: Pe►iodic speciai �nspectiori is �requi�ed, in aoco�ance wifh Section '1705 1.1 :ar�d Tabfe 1705,3 of #he 2015 (BC and 2012 IBC; 'Section 9704:15 of the 2009.116C; or Section `17�4.13 �of: �he 20p6 IBC,, as ap,plicable. The s�cial inspector musf be on the site: periodically during anchor instailation'to •verify anchor type; �anchor dihiensions, ��hole dimensions, conc�ete type, concrete compre5sive stre�agth; dnll ,bit .typ� anil size, hole, dimensions, tiole cleaning proced�res, `ar�chor spacing(s),,'edge�distanoe(s), concre4e member. ihiGcness, anchor,embedr�ent, installation to�ue, �mpact vdrench poweraad adherence.to the manufacturer''s �printed in�tallation ins.truc6ons ��nd .the •cond�Uons qf�this repo�t {in 'case of conflict, ttiis report gove�ns): The special �inspector ,rriust be, -p�esent as often as required 'in accordance'witt� �the °stafement of speoia'I ir�spection." Clnder the'. 98C, � additional �requirements as s.et. forth in ,SecEions '1705; 1706 and 1707 must be observed, wh�re �applicabte.: . . 5 0: �;CONDITlONS OF USE Tiie Him, '1QMK HUS-EZ (#CH EZ) and iC1NIK :HUS-EZ ;I {�CH-EZ 9} conc�et'e anchors .described in :this_ repon are suitable alternatives #o what is specified in, �hose codes listed in Section 1:0 of this report; subJect to ttie folloinring :conditions: �5.1 'The :anchors must be installetl in .accordance with the manuTaciuret's pubtislaed installation insWctions and ftiis .report. In case of conflict, this report govems: 5:2 Anchor sizes, :dimensions, �and minimum :embedment depths are as set forth in tMis report. 5.3 Anchois must be. insiatled in accordanoe w'ith Section d.3 of �this report in unctackecl ,or cracked raorrnai- •welghf conc�ete and sand-lightweight concrebe Fiaving a�specified compressive �strength, ''f`c, of 2,500. psi to 8,500:psi (17.2 MPe to 58.6 M�a) [minimum of 24 MPa is required :under ADIBC Appendix L, Sec6on 5:1.1], 'and �cxadced :arid� u�c�acked riormat=weight or sanrl- lightweight _-concrete over. metal deck' . having, a minimum specified.:ccmpte§sive strer�gth P�, of 3,�Q0 psi {20.7 MPaj (minimur�a of 24 MPa ;is required under ADIBG.Appendix�L•, 5ection 5.9.1]. 5A„ T�►e value of �'�'used for calcufation purposes �iust no4 exceed $;000 p'si {55.2 MPa)r C12 ESR-3�2i � Most �dely Accepted and Tiusted Page 5 oi 14 5.5 Strength design values must be established in accordance with Section q.1 a# this report. 5.6 Allowable stress design values must be established in accordance with 5ection 4.2 of this �eport 5.7 Anchor spacing(s) and edge distance(s), and minimum member thickness, mvst comply with T�ble 2 and Figure 5 of this reporf. 5.8 12epoRed walues far the KIMK HUS-�Z I(KH-EZ I) with an intemally threaded Mex was'her head do not consider �he sfiesl inser� element which must be verified by the design professional. Shear design values in Yhis �eporE for the K1MK #1US-EZ I(KH-FZ I) �re for ihreaded inserts with F„ equal to qr greater than 125 itsi. For use with fnserts with �„ less than 125 ksi, the shear values are muttiplied by the �atio of Fu of insert and 125 ksi. 6.9 Prior io instellation, calculations and details demonstrating compliance with this report must be subr�itted to the code oificial. The catculatians and details must be prepared by a registered design prafessional where required by the sta#utes of the jurisdiction in which the proje�t is ta be conshucted. 5.10 Sinc� aro IGC-ES acaeptartce �riteria for �valuating data to determine Rhe perforrnanoe of anchors subjected to fatigue or shoGc loading is unavailabfe at this time, the use of these anchors under such conditions is beyond the scope of this report. 5.11 Anchors may be installed in regions of concrete where cracking has �occ�rred or where anafysis indicates crackirag may cccur {i�f,j, subject to the conditipns of this report. 5.12 Anchars may be used to resist short-4erm loading �due to wind or seismic forces, subject to the conditions of this repari. 6.13 Anchors are not permitted !o support fire-resistance- rated consi�udion. Where not otherwise prohibited in the code, anchors are permitted for use with flre- rssis#ance-ratad canstruction provided that at least one of fhe following cflnditions is fulfilled: • Anchors .are used to resist wind or seismic fiarces only. � Anchors #hat support gravity load—bearing structural elements are within a fire-resistance-rated envelope or a fire-resistanoe-rated membrane, are protected by approved 6re-resistanae-rated materials, or fiave beer� evaluated for resistance io fire exposure in accordance with recognized standards. • Anchors are used to support nons#ructura9 eiements. 5.1A Anchors have been evaluated fior refiabifity �gainst brRtle failure and found to be not significanUy sensitive to stress-induced hydrogen ernbrittlement. 6.46 Use of carbon steel anchors is limited to dry, interior locations. 6.16 Special inspection must be provid�d in accordance with 5ections 4.4. 5.17 K1MK HUS-EZ (�tH-EZ) and K1MK �iUS-EZ I(KFi-EZ I) anchors are manufactured �,y Hi1ti AG, under a quality conttol program with inspections by ICGES. S.0 EVIpENCE SUBMITTED Data in accordanoe with the iCC-E5 A�eptance Criteria for Mechanical Anchors in Ct�ncrete �lements (AC193), dated June 2Q12, (editorially revised April 201Sj, which incx�rporates requirements in ACI 35�.2-07 / ACI 355.2-04, #or use in cracked snd uncracked concxete; and quatity contral docur�entation. 7A IDENTIFtCATIQN The HILTf K1MK HUS-EZ (KH-EZ) and KIMK �1U5-� � (KH-EZ I) anchors are identified by padcaging vYith the manufacturer's narrae {Hilti, Inc.) and cantact infiormation, anchor name, ancho� size, and eva1uatiora report number (ESR-3027). ihe anch4rs with hex washer head h�ve KH-EZ, HILTI, and anchor size and arachar kength embossed on the anchor h�ad. Identiflcations are visible after installation, for verification. C13 ESR-3027 I Mpst Widely Accepted and Trusted Page 6 of 14 �7ABLE 1—KWIK HUS-EZ (KH-EZ) AND KWIK HUS-EZ I jKH-EZ 1) PRODUCT INFORMATION Name and 5ize Diameter Tp�� Length - under the Minimum Nominai ancfior head {I„,�,� Embedment (h,,,,,,j KFi-EZ'J4" x1 �/e" I'/4' �l# ('l�" UNG20 --Intemai Thread Length -.375") 1s/e" 36/�" KH-EZ'/4" x9 s/e, I 3/e' 'I�" ('le" i1NC-16 --Intemal Thread Length -.453") �s�o. .�s�a« KH-E2'I�" x2'/?" I"/4" "l�" ('!," UNG20 —Intemal Thread Length -.375"j 2'/2" 2'(2" KH-F_Z'/4" x2'!z" I 3/�" '/4' ('/6" UNC-18 —Intemal Thread Length -.453") 2'iz" 2'12" KH-EZ'/."x1 '/e" i�4 � �1s. �s�a. KH-EZ �/�"�t251e" 'l�" � 25J8" 151e" KH-EZ'l�"x3" "/q 3" 15/&" KH-EZ'(.'x3��a �la. ���Z� �s��. KN-EZ'Ja"x4' ,/,• 4• 'ls�e• _ __ _ __ KH-EZ ale x17ie" 3/a" 1�/e" 13/a" KH-EZ'/g"x2�ls" 9/e" 2'!e, 1 s/a" KH-EZ 9/e"x3" 3/a' 3" 2'12" KH-EZ 3/�"x3,�z� 9�8. 3,�2. 2,�2. KH-EZ 91s"X4� 9Jar 4" 3t/a" KH-EZ 3/e'x5� gJ6� 5° 3'!a" KH-EZ'/2"�c2'/2" '/Z 2'/z 2'/," KH-EZ ,�2.x3. i�2. �. Z��4. KH-EZ ,�2.x3't2. ,�s" 3'(z" 3' KH-EZ'/2 x4" 'l2` 4' 3" IfH-EZ t��.Xdro�2. ��Z• 4�/z �. KH�EZ'Iz"x5" '/Z 5" 3' KH-EZ �y2"x6` 'tz" 6" 3" KH-EZ s!B x3'/i 51a" 3'Iz' 3'i+" �_� s�a.x4e 5�6� 4w 3,14� KH-EZ b�e.x5��2. s�a. ���z 3,�t. i�'�'� S�B�%C���2� b�p� . . 6��2 �'I.{� �{�"�-�z 6%B�iiB 6�9� 8� 3ilq� KH-EZ �/a`x4'/Z 3/�" k'!2 4" KN-EZ'/,"x5Y2. 3�4. 51��. 4. iC�i-�Z 3%#�X% gii % 4� KH-EZ 3/,"x8" g/," 8" 4" Ki'�"� 3���X.� 9I4� � 4� For Si: 1 anch =25.4 mm. C14 ESR•3027 I Most Widely Accspted and Trusted Page 7 ot 14 �,. � r 4 _ FICiURE 1--KWIK HUS E2 ANCHOR +M► � �! � '� � ! � . y�„�,� e.'; i( ; FIGURE 2--HILTI KWIK HUS E2 CONCRETE SCREW ANCHOR _..,.�.�...�. .r� �,:. '�� -�� �� FIGURE 3—HIL71 KWIK HUS-EZ 1 ANCHOR � � »� �.� '� IT � € -w; t �� � �3 � � ��-� { ..,�,r � � .� � }, � � � _ .� �. . � � .� � rr ¢ . _ __ � . ELMr �a►r �ru apKM W�p Propw �rerM� �M� 011 ', C�n etlre �aM b w�now MORM : , � �� . �"�� ..� M �m�. � 1��'4� � �, ��sc�ss��� ,� �� :�q�-� ��� � y q`� �Rr FIGURE 4A-9NSTALIATION INSTRUCTIONS – HILTI KYVIK HUS EZ (KH-EZ) 4� � �� !�l�f�i tiC #.�..�..... , .. __.. .. i0rr� nWe �+ oau maknat �Ms� proper o+�meaer aw on ���-� � �_ �.. rinst�ll�ncnorus�nq p►oDsr Imp�ct�oW a tw�uewrench; � ���!���� . ' „� ...� . _... _.. . ....... . _ SGkan WM1ed Aok 4o u+novt tleWis � � �� , * � I _..__._.__._v___.___�.__,_..__.___.____ ___ �rnenas►Eaaee.aalnta insnlMsiasacnor ; _. FIGURE 4B—IN8TALLATiQN INS7RUCTIONB – HILTI KWIK HUS EZ 1(KH-EZ 1) C15 ESR-3Q27 � Most Widely Accepted and Trusted �'age 8 of 14 TABLE 2-KWIK NUS-EZ {KH-EZ) AND KWIK HUS-EZ 1(KH•EZ I} INSTAILATION INFORMATION AND ATICHOR SPECIfICATIQN' Nominal Anchor Diameter {inches) ' Characteristic Symbol Un"rts � �(KH �EZ 1) ila �la '12 61c s/o H@ad Style _ _ Intemally Standard Hex Standard Hex Standard h3ex Standard Hex Standard Hex Threaded Head Head iiead Head Nead Nominal Ufatneter ��a�, in. '!, '!a '/s 5h '/. Driil Bit Diameter dwr in. �1� �Je 'Is 5la 3J� M(nimum Saseplate a a , s 3 t Clearance liole Diameter d� in. N/A i6 Iz 1a l. le Maximum In§tatlation T��x+ ft-Ibf 18 19 40 45 �B5 195 7orque Maximum Impact Wrench Torque Rating3 T�„A,�,m„ ft-Ibf 114 137 114 137 114 450 �37 A50 450 450 Mimmum Nominai h� in. 15/e 2'1, 16/n 2'!s 15/a 2'Jz 3Yn 2'l� 3 4'l, 3'I� 5 4 6'ia fmDedment depth Effective Embe�ment Depih h.� in. 1.18 i.82 1.18 1.92 1.11 1.86 2.50 1.52 2.98 3.22 2.39 3.88 2.92 A.84 Minimum Hole Depth hl,y, +n. 2 2�/� 2 2'/e 1'!e 23/{ �'�z 25�a 3'18 4Fld 3�/e 5'ls 43/s 85/e Critical Edge Disiance' ck in. 2.00 2.78 2.OU 2.78 2.83 2.92 3.75 2.75 3.75 5.25 3.63 5.82 4.41 728 Minimum Spacing at Cridcal Sm�pGi �� �,,0 2.25 3.0 Edge distance2 Minimum Edge'Uistance� c,,,;,� in. 'f.50 1.75 Minimurn Spacing Distance s,,,;,,f in. 3.0 4.0 at Minimum Edge Distance lVlinimum Concrete �rt� in. �.25 9.125 3.25 d.125 3.25 4 435 4.5 4.75 6.75 5 7 6 8.125 Thickness 'I,C Intemai ,�� Wrench socket size - Thread �� Npt Applicable KH-E21 Model !a" Intema) ;�Z Thread Wreneh socket size - in. N/A 'l,� °l,e '�� 's�,a 1�/e KN-EZ Modei ' J4" internal s�� ?Jlax. Head height - Thread in. Not Appiicable KH-EZ I Model /a Intemat „��6 Thread Max. Head Meight - in. N/A 0.24 0.35 0.49 0.57 0.70 Effective tensile sUess area A" s in? 0.045 0.086 Q.9fi1 0.268 0.392 (A«.k) Min"unum specified ultirttate �� pSi 125,000 106,975 420,300 112,540 90,980 81,600 strength �or 51:1 inch = 25.4 mm, i ft-Ibf =1.356 N-m, 1 psi = 6.89 kPa, 1 fn` = 845 mm`, 1 iblin = 0.175 �Slmm. 'The data presented in this table is �o be used in conjunctfon with the design crikeria oi AC! 318-i4 Chapter 17 or ACI 318-11 Appeodix D, as applicaWe. r �For installaiions ihrough the soffit of steel deck into concrete (see Figure 5) anchors instailed in ihe lower flute may be installed with a maximum 1 inch offset in either direction from the center of the flute. � Because of variability in measurement procedures, the pub8shed torque oi an impacl tool may not correlate properly with ihe above setting torques. Over-torquing can damage the anchor andfor reduce its holding capacity, �Ti,,.,,,,,exapplies to insfailaUons using a calibraied torque wrench. SThe notaUon in parenthesis is far ihe 20061BC. "The KWIK HUS-E21(KH-EZ f} version is driven directlyto the suppohing rtiember surface. 'AddiGonal cambinaUons for minimum edge distance, c,,,u„ and minimum spacing distance, s„�„ or s,,,�,�.�, may be deriwed by linear interpolation betwaen !he given boundary values. C16 ESR-3027 J Most WidefyAccepted and Trusled Page 9 of'I4 TABLE 3-HILTI KVYIK HUS-EZ tKH-�Z) and K►NIK HUS-£21(KH-EZ Ij iENSiON STRENG7H DESIGN DATA'�`�' Nominal Anchor Diameter(inches) Characteristic Symbol Un9ts , {� �� �) '/� s!e '/? �!s 'l� Anchor Category 3 1 3 1 1 1,2or3 Hea� Style _ _ iniemally Standard Hex Standard Hex Standard Hex Standard H�x Standard Threaded Nead Head Head Head Hex Mead fdominal y� in. 1°/a 2�/z a5/a 2'/i 15/e 2'/a 3�l� 2'/� 3 d'l� 3'ls 5 4 6'/� Embedment De th SteelStrength in Tension (ACf 398-i417.4.t or ACI 3i8-11 D.5.3) Tension i2esisiance N« fb. 5,660 9,200 10,335 98,120 24,210 32,015 of Steet Reduction FaGor for Steel Strength'�a �, - 0.85 Concrete Breakout Strength in T�ns3on (ACi 31 B-1417.4.2 or ACI 318-11 D.5.2) ENective h,� in. �.18 1.92 1.18 �.92 1.11 1.86 2.50 1.52 2.16 3.22 2.39 3.88 2.92 4.84 Embedment Depth Critical Edge �x in. 2.00 2.78 2AU 2.i8 2.63 2.92 3.75 2.75 3J5 525 3.63 5.82 4.41 7.28 �istance Effectiveness Factor - Uncradced k,,.,o, - 24 27 Concrete Effectiveness Factor ka -CrackedConaete ` 17 Modificalion iactor %r cracked and 4�SN - 1.0 uncracked concrete° 42eduction Facior for - - - Concrete Breakout �,, - 0.45 0.85 0.45 0.65 Stren thZa Pullout Strength in Tension (Non Seismic Applications) (ACI 318-i417.4.3 or AC1318-17 D.5.3) Characteristic pullout strength, �R�� Ib. 1,305° 2,3505 1,305° 2,3505 N!A N/A NlA N/A N!A N/A N/A N/A N!A ' N1A uncracked concrete 2,500psi Characteristic cralck dcroncrete 'Nmp� Ib. 665° 1,1655 665° 1,'�fi55 7256 N/A N!A N/A NIA hlA NIA N/A N/A', N/A 2500 si Reduction facto 2for � . 0.45 0.65 O.dS puilout st�ength • 0.65 Pullout Strength In Tension (Seismic ApplicaGons) (ACI 318-1417.4.3 or ACI 318-11 b.5.3) Gharacteristic PulloutSVength, ', Na.,' Ib. 535° 1,1655 535° 1,i653 7255 NIA NJA N/A N/A N/A N/A N/A N/A t�/A Seismic 2 500 si Reduction Factor for Pullout'Strengthz'' �6,,, - 0.45 0.65 O.AS 0.65 (2,500 psi) Axial StiNness dn Service Load Ra�ge Uneracked Concrete �,,,,,, 760,000 Ibrn. Crecked Concrete �„ 293,b00 For Sl:1 inch = 25.4 mm,1 fl-Ibf =1.356 N-m. 1 psi = 6.89 kPa, 1 in2 = 645 mm2. 1 Ib/in = 0.175 N/mm. jThe data i� this table 1s tntended for use with ihe design provisfons oi ACI 318-14 Chapter 17 or ACI 3f 8•19 Appendix 0, as applicable; for anchars resisting seismic load combinations ihe additional r�equirements of ACI 378-14 17.2.3 or ACI 318-11 D.3.3, as applicabie, shall apply. ZValues of f in this teble apply when the load combinations for ACI 318-14 Sectbn 5.3. ACI 318-11 Section 8.2 or IBC Section 1fiD5.2 are used and the requirements oi ACI 31&14 17.3.3 or ACI 318-'d 1 D.4.3, as applicable, for Condition B are met. For situations where reinforcQment meets the requirements oi CondiGon A, ACI 31&14 17.3.3 or AC131&1 A b.4.3, prov�des the apprapriate ; tactor, as applicabie. �If the bad combinations of ACI 318-99 Appendix C are used, the appropriate value oi � musi be determined in aocordance with AC1318-11 D.4.4. 41n this report, N/A denotes that pulbut resistance does not govem and does not need to be considered. SThe characterisiic pullout resistance for conerete compressiv+e strengths greater than 2,500 psi may be increased by multiplNng lhe value in 1he tabte by (Pa/2 500)oa for psi or (P�i7.2joa tor MPa. °7he characteristic pullout resistance for concrete compressive strengths greater than 2,500 psi anay De increased by multip�ying 1he value in #he t�b1e by (Pa/2,500)0.9 for psi or (Pa/i Z.2J°� for MPa. 'For sanddightweight concrete, calculate values according to 5ection A.1.12 of this repoA. �'The KWIK HUS-EZ (KN-EZ) and KWIK HUS-EZ I(KH-EZ f) is considared a britile steel elem�nt as defined by ACI 318-14 2.3 or ACI 318-17 0.3, as aPplfcable. C17 ESR-3027 I Nlost Widely Accepted and Tr�sted Page 10 of 14 TA9LE 4--�ILTI KWIK HUS•EZ (KH-EZ) and KWIK HUS-EZ 1{KH-EZ I) SHEAR STRENGTH DESIGN DATA'•' Nominal Anchor Diameter �iraches) Characteristic Symbol Unks +�+ , , � 5 s (Kfi-EZ I) /s !` !2 /e la AnChor Catec�Ory 9,2 or 3 3 1 3 1 3 1 1 Embedmerak Depth h,�m in. 15/, 2'/2 1°/s 2'/2 15/B 2'/z 1s1, 2'!� 3'/, 2'l,� 3 d'l, 3'la � 4 6'!. InternaiThr�ad _ � +�� 3�8 N/A NJA N!A NIA N/A N/A NJA N/A NIA N/A NIA N/A piame#er Steel Strength in Shear {AC! 31$-1417.5.7 or ACI 318•17 D.6.1)�'�' Shear Resistance of �� 1b. , 1,360' i, 315' 1,550 3,670 5,185 9,2a5 11,220 16,660 Steel - StaUc Shear Resistance ot ���q �b, 605' 1,120' a,395 3,670 3,110 5,545 6,785 91,555 Steel - Seismic ReducGon Faclor for D.sO Steel Strength3 �" - Concrete Breakout SUength ia 5hear (ACI 318•941�.5.2 or ACI 318-11 D.6.2) NominalDiameter d,(d,J° in. 0.250 fl,375 0.5Db 0,625 0.750 Load Bearing !e in. 1.18 1.92 1.18 1.92 1.18 1.92 1.11 1.86 2.50 1.52 2.16 3.22 2.39 3.88 2.92 b.84 Length of l#nchor Reductian �actor tor Concrete 8reakout �g - 0.70 Strength��' Cancrete Pryout 5trength in Shear {AC1378-1417.5.3 or AC1318-11 D.6.3) Coefficieatfor k - 1,0 1'.0 1 A 1.� 1 A 1.0 1.fl 1,0 2.0 1.0 L� 2.0 1.9 2.0 2.0 2.0 Pryout Strength `F Reduction Factor for 0.70 Pryout Strength�'' �P For SI: 1 inch = 25_4 mm. 1 ft-1bf = 1.356 N-m. 1 osi = 6.89 kPe. 1 in2 = 645 mm2. 1 Ibtn = 0.175 Wlmm. 'The data in this table is intended for use with ihe design provisions of ACI 318-�4 Chapte� 17 or ACf 918-17 Appendix �, as eppficabie. 2 Vatues of � in this tabte appty when the load combinaifons for ACi 3i&� 4 Section 6.3, AG1318-11 Section 9.2 or IBC Section 1605.2, as appticable, are used and ihe requiremenis of ACI-1 d'17.3.3 or ACi 318-11 0.4,3, as applicable, tor Condition B are met. For situaUons where reinforcement meets lhe requittarraenls c�f Cflndition A, ACI 318-1417.3.3 or AGi 318-11 Q.4.3, provides ttae a�ropriate � factor, as appticable.. 31f;he load combinatians of ACI 31811 Appendix C are used, ihe appropriate value oi / must be determined in accardance �1h ACI 318-91 b.4.4, 'Reporked values for steei strength in shear are based on test results per AC! 355.2, Section 9.A and musi be vsed for design in 1'�eu of calculated resulis using equalion 17.5.1.2b of AC131$-14 or e4uation D-29 of ACI 318-19, as applicable. �i'he KWIK F1US-EZ �KH-�2) is consfdened e britde sieei elemeM as defined �y ACI 318-14 2.3 or ACI 318-11 D.1, as applicable. �The noieiion in breckets is for iha 200619C. �Values are ior threaded rod or insert wHh F„�125 ksL For use wiih 7nserls with Fu less than 125 ksi mult(ply the shear values by the ratio oi Fu of inseA and 925 ksi. ESR-3027 � Most INiiielyAccepted and Trusted Page 11 o.f 74 i'ABLE 5—Fi1lTl KWIK HIIS-EZ 4i(H-F.�) TENSfpN AAfD $HEAR DESIGN DA7A FOR INSTAAIl.A'T1�N'ft� 1H� WND'ERSID� ' OF CONC _RETE-FILL'ED.�ROFILE SfEEI DECICIIS$EM81:1ES'�'&' Lower Fluta �llpper Fiute Characteristic Syrribol ! Unks Anchor Diameter 'J4 �3/s �12 5le , g1< '.14 �Ce 1i2 I — _ ;Head Style r = Standerd Hex 4iead Star�dard Heic Heail Einbedment h„�„ in. ' 3'SJS 2'/2 1% ' 2.'!2 3'/a '2'f< '3 ' 4'7e 3'l. I'S 4''15Ig 2'!2 13! 2't7 2'!4 9 5� 5 -8 " 9 . ..� 7 7" 7 5 AAinimum Hofe Oepih' h� in. �.2 ' 2'Ja �1'/e 2°1� 3�/� , 2jle 3 Jb :'4' 18 3 JE �S./o 4 Je `2 2/s �I !b 2Je 2.1e �ffective £mbedmenf hEr 'in. ' 9.18 1.$2 '1.91 1.86' 2:50 'l:52 2:16 3:22 2,3J 3.88 2.92 'l :i 6 1:92 i:11. 1;86 1:52 Depth � i�u'llout i28sistariCe; (uncracked concreiej� NRd�,,,�,, Ib. 1,2101;875 i.900 2;240I� 3,920 7;305 3;060 5;360 4;18p 9;995 4,180 9,490 i,960 1,490 2,928 1;395, �PuYlout Resistance ,(c.�atked conctete and `N��, Ib. 620 930. $10 'l;b90 2,780 82D ' 1„930 3,375I 2;630 5,980 2.630 760 975 1.185 2,U70 �985 seismie loads �- ' $teel StrenQtfi•in ��� �b. 1;2052;210 a,510� 1;5a0 3,60b 1,605' 2,920 3;590 3,470' 4;790 3,�60' 1,205 3;265 '3;670 8,090 7,850 Shea�` _ . _ .. , _ ._ _ _ 'SteelSirength'in v�d�4� .jb, 8D5 1 990 '905 905 ' 3;165 _965 , 9,750 755 2;080 2;5'15' 2;61D 3;080 2,990 3,670 3,fi50 4;7i0 Shear: Seismic . . - . � �.., - _F- - , 2 , .. . _ -- --- ---___ _ For 51 1 inch - 25 4 mm,1 ftdbi -1:35fi N-m,1 p"si - 6,69 k�a,1 en 643`mm�,1 Ibfin =.0.175 Nlmm: '�In$fabation must comply with Sections d.�.9D and 4;3 and figurc 5 at this repoit: 27he.values listed must kie use8 in accordance wifh Section 4.1:4 of this repoA. 'The values listed must ibe used in accordance yvi(h Sebiion 4:1;4 and 4.1:8.2 oi this report. °Tt� values listed musi �be osed 3n accordance with Section 4.1.5 �nd 4.1.8.3 oT ihis reportr SThe'values;tor �pin leosion can !tie found in'fiable � atlhis report and thevaiues ior��„ `rn shear can be tound +n Tabfe 4 of ihis rspoti. 6Fo{ ihe'/4-inch-diameter (KN-EZ) ai 2'.l2rnch nominaf embedmenf and the 9/�-inch- throu9h �,l4-inch-diemeter anchors ttie :characieristic �ullout tesislance.?ofconc�ele campressi�e sUengVis greatei ihan 3,QOD psi ma,y be increased by rnultipiyirig the value.iri ihe ieble by (f�3,000) in'for psi or ir�0 ��ort for MPa. .. . . �For 1he �/�=inch-dlametet anchors ;(I<H-EZ) at 1 Je=inch nominal e'mbedment charactensticopullout res�stance for concrete aompiesSive strengFhs greater than.3;000 psi rnay be inc�eased by multiplying thevalue tn the'table'by (P,.,�l3;000) :3 fot?psi or {T�120:7)°�' for�NlPe: �ABLE 6�—KVYiK IiUS-EZ I:(KH=EZ I) TEMSiOhI.ANb SHEAR DESIGN DA7A FOR•iNSiALLA'ftON IM'T'�iE UNDERSIDE OF CONCR�'t�- FILI.��Il PRO�lI:� STEEt DECK ASSEMBLfES''°'' . _ __ _ _ __ _ ChacaCterisUc S mbei Untts • - LowerFl�fte -_-___ _- - U e7Flute. _� :Head S e lntematl 7hreaded _ _ ��mbedment" h,,,,,, in; 15/e, 2'/z j 151� 2'JQ' 'l5/8 2�12 'ISJe 2'�2 , _ • _ _ h� , m. Minimum'Ho�e 2- - 27�8 � ,2ile; 2 2�/e 2, .2�/e �- Deth. � ,. >. .. . InteDiame erad ' an. ° - 'la ;�/e � ��� -- a/� . --_ � Effective. ' h;l. in: 'I:iB• 7.92 '118 ]:92 1.18; 1:92 1.18 `1.92` Embedmen{ De 'th ' . : , . . , . Pullout Resistance; `(unaadced Np�;,g;w Ib. y:2i0 `i„$75 1,210 1;875; <1.d9U 1:960 1,,490 3;960 ooncrete ' - ' ----- ' - Pulfout �Resistance (cracked concrete N�,,;a;� Ib. 620 � 930 52p 930: 730 975 730 975 . and seismic load' 3 : - _ Steel SVen�9 th In a �b: k$60 1,Q25 i;015, i,525 SheaY' vs'.°°r!� Steel Strength �in e Ib. '385 875 445 'i r295 Shear • Seismic : �",°°`�°? ' - . - _ _ For SI: � inch = 26.4 mm. "I ft-!bf`=1;356 N-in, t psi = 6.89:kPa; 1 in2 = 645 mmz, 1 Ibin = A.1ib .�i/mm: 'Installation mustcomplywifh Seciions 4:'! 10 and 4.3 and �igure 3 oitliis report. 2The values listed �nust be used in 8ccordance with SeCtion 4.1:4 of this repofl. . -�'ftte values listed +nusl be used in accordance with Section 4.1:d and d.1:b2 oi iFns repori. °Ttie values lisled must'be used in •accordance witti Section 4,1.5 arid 4.1.8:3,oi this �epoit. 6Tlre values ior,+p in tension can be tound in'fable 3 qf lhis tepoA aritl ihe value"s for ��,�in shear can be'found in Tabl.e d"oi this repoA: BFor the "lr���h�iameter (KN-EZ 1) at 2�/2 inch nominal ;embedment and the aJ�-Inch- throug6 3Ia='incfi�iameter anchors ihe cheraCteriSNc pullotit resisfance tor concrete compressiva strengUis greate� than 3,000 psi may!be �ncreased by muftiptying ihe vatue in tlie'table by {f,r3.,000J'n fo� psi or �f,�2O.TJm for NIPa. . For the �/, inch-diamefer anc}iors (KH-EZ �) et 151e-inch nominal embetlmeAt cfiaracterisUc �ullout resis[ance'for conc,�ete compressive strengths greatef than 3:;000 psi may be increasetl by'mutGplying the vafue m!he table by (f,/3,000J°'s'for.psi or {Pa%207)a� tor MPa. "BValues for the icWIK HUS-£Z I{K1i=EZ Y) are for ihreaded rod oi msert with. F„i125'ksi: For use with.inserts with Fu less lhan i�5 ksf multipty tFie shear values byitie ratio af Fuo�inseA and i25 ksi, C19 ESR-3027 ( Most �dely Accepted and Trusted Page 12 of 14 TA81E 7.--HILTI KV►►�K HUS—EZ (KM•EX� SETTING INFORMATlON F012 INSTALLATiON ON THE iOP OP CONCRETE-FlLLED PROFILE STEELDECK ASSEMBLIES �'�'�a,s,e,t DE5iGN Nominal Anchor piameter �NFDRMATION Symbol Units ,�� s�s EffecUve h.r in, 1.38 1,11 Embedment De th Minimum concrete ��� in. 2'J2 2'1Z lhickness CritiCal edge �n. 4 3 distan0e �•4ee�,'°a Minimum edge in. i'l� 181q distance �""",de`'.`°" Minimum spacing Sm�n,esd,mp �n. 3 3 For SI:1 inch = 25.d mm. 'Installation must camply w'dh Sections 4.1.10 and A.3 of this report. ZFor all othet enchor diameters and embedment depths refer to Table 2 for values of hm,,,,Cmc� 3�1d Smm. 3Design capacity must De based on caiculations according to values in Tables 3 and 4 of this teport. 4Applicabie for 2�h-inch <_ hm„,,,�;s{3'!,-inch. For �m�,,,,,�x Z 3'!4-Inch, use seiting intorm�tion in Tables'3 and 4 of this repori. SMinimum concrete ihi�kness (h,,.,,,e.n,) reters lo ooncrete thickness above upper ilute. 6Minimum f{ute depih (distance from top of flute to b4ttom of flute) is 3 inches. °Steel deck thickness musl be minimum 20 gauge. See '�QOff1DiE � Max. 3"' Minlmum 9-7/4" � S�e�e tootn�te 2 Min. 3,000 �s� sanda�n�we�gnt or rnrcnai-weighi concrete Upper � 1lute (vaNeY) � �' I � � � i Atyct�or/'� ' �.ower Flwte (rypical) � I Ilu1e (ridge) edge I � Ii M��. 14� �tyY"�^"�I �) i --� �4— See tootnote 4 ----►� Minimum 2t) g�uge stc�i deck See #vainote 4 FlGURE 5—INSTALLATIDN OF KVNIK HUS•EZ (KH-E2j AND KWiK HUS-EZ I(KH-EZ I) IN SOFFIT QF CQNCRE'fE OVER STEEL DECK FLOOR AND ROOF ASSEMBLIES 'Anchors may be placed in the upper or lower flute of the sieet deck profile provided the minimum hote clearance is saGsfied. Anchors in the lower flute may be instailed wHh a maximum 1-inch offset in either direction from the center of the flute. �he offs,ei distance may be increased proportionaily fdr proTiies with lower fluie widths greater than those shown provided the minimum lower flute edge distance is aiso satisfied. ZMinimum tlute width for KH-�Z and KH-EZ 1'/.-inch diameter is 3'I� inches. Minfmum flute width tor KH-EZ'/e-,'/r, 5/�- and �-inch diameter is 4'/� inches. �Minimum concrete thickness abave upper #lute for KM-EZ and KH-EZ I'/,-inch diameter is 2'/Z inches. Minimum concrefe thickness above upper flute for KH-EZ 9/�-, %r, �/r and %-inch diameter is 3-'14 inches. 'Minimum distance from edge of flute to centerline of anchor for KH-EZ and KH-EZ I'/,-inch diameier is 9anch. Minimum distance from edge oi flute to ceMerline of anchor for KH-EZ 3/e�.'�-. ��e- and'J.-inch diameter is 3'I. inches. C20 ESR•3027 j Most �dely Accepted and Trusied Page 13 of 1b TABLE 8—HILTI KWIK F9US-EZ (KN-EZ� AND KWIK HI�S-fZ I{KH-EZ i) AILOWABLE STRESS DESIGN VAIUES F�R ILLUSTRATIVE PllRPOSE S'' z, a. a, e, e, �, e, a Nominsf Anchor �aminal Effective ppawable Tension Embedment Depth, Embedment Diameter h,,,,,, Depth, h., �.oad [in.] [in.] [in.� �IbsJ � i5/s t .18 407 1. 2'/2 1.92 1,031 15/e 1.1 � 82Q '/s 2'!2 1.86 3,334 �"�a 2.5 2,077 2'/4 1.52 9.911 '!z 3 2.16 1,882 4"/4 - - 3.22 3>426 6 3'/, 2.39 2,192 /e 5 �.88 4,530 9 4 2.92 2;963 /„ -- 611,; �t.$4 8,305 F�r SI;1 inch = 25.4 mrr�, 9 Ibf = 4.45 N. '$ingle anchor with statiG tension load only. ?Goncrete detetmined to remain �ncracked fior the life of the �n�horage. �Load combinaiions are taken from ACI �18-14 SecUon 5.3 or ACI 318•1 � Section 9.2, as appiicabie, (no seismic ioading). 'AD% dead Ipad and 60°� live load, �contro1ling load c.�imbinaGon '1.2D + 1.SL. �Galculation of w�ighted average fw conversion factor a=12(0.4) + 1.6(0.6) = 1.44. e t� = 2,500 psi (normal weighi conc,nete). '�.a=c,,ac,�. e h 2 h,,,,,. QUatues are for ConGition B where supplementary reinforcement in accordance wit� �+4CI 39$- 14 17.3.3 or ACi 31$-11 D.4.3, as applipble, �is not provided. C21 ES(t-30�7 N Most Wrdely Accepted and Trusted F'age 14 of 14 Given: Two "/z" diameter KH-EZ with static tension load n!� 4 Y,�� A h,,,,,, = 4.25 �nches ,�,��`-;y _ _ A 1 � h�r= 3.22 inches � ,' .+�tytt ��' �i + " ( > �.s e�., Normai Weight Concrete: 1 � = 3,�00 psi 'r� � � .� .� ,� #; � I l No supplementary reinforcement (Cond. B) €i ,� �� * �yA�j_ �- Na eccentricity, 60% live load, 4U410 dead load. ; -► ; � � • � .f} � + ; , ` �• Assume cradced concrele sincQ no other information is available. �� �-�. �; �_ ��1`�-�!'�� �i � h 6.375 7n. s.,___ __: � ��,s H„ Cmin='I.�%S lfl. 'a t3.ii t_ �?'�� ._ .! sm�,=3 In. n.n Needed: Allowable stress design (ASO) tension capacity Calculation per AC1318-14 Chapter 17, ACI 3l8-14 AC1318-11 ESR ACi 318-11 Appendix D and this report Ref. Ref. Reference Step i: Calculate ste+ei capacity: 17.4.1.2 D.5.1.2 Ta'b1e 3 �NS=n¢N�=2{O.SS)(18,120)=23,55fi Ibs. Step 2: Verify minimum member thickness, spacing and edge distance; hm� 6.375 in. 512 in. -+ok c,,,m=1.75 in. s4 in. -+ok 17.7 D.8 7able 2 s,,,�„-3 In. 56 in. �•ok Step 3: Calculate concrete breakout sVength of anchor grpup in tension: Aac 17.4.2.i D.5.2.1 4.1.3 Nr.,p=�� y'ec,r�y'ea.w�c,NwtP.NNb Step 3a: Calculate Ant and A�: ANc=(1.Sh�+4)(3he1+6)=($.83){1�.$6)=13$.3 ii�.2 17.-02.1 D;5.2.1 Tab1e 3 AN�=9(h�)2=9(3.22)2=93.32 in � StQp 3b. Determine W,�,N—rB��-+W�,�.�=i.O 17.4.2.4 D.�.2.4 —. _ _ Step 3c: Calculate W�,N-+W�,N=0.7+0.3�4��=D.948 17.42.5 D.5.2.5 Table 3 Step'9d: Determine 4+�,N--, W�,N=1.0 because concrete is cracked. 17.4,3.6 D:5.3.6 ---- Siep 3e: Calculate Na: Nn=ka�l, f�{h�)t 5=17(i.0) 3.000(3.22)�.s=5.3801bs 17.d.2.2 D.5.2.2 Table 3 {A, =1;01or �ormal weightconcrete) Step 3f: Calcutate �N�bp: ¢N�={0.65) �738�� (9.0)(0.948){1.U)(iAj(5,38D)=4,9a4 ibs i 7.�4_2.a D.5.2.1 4.1.3 e�3z d7.3.3 {c) D.4.3 (c) Table 3 Step d: Check Puliout Strength -� per �'able 3 idoes not conUol --- --- 7abie 3 Step 5: Controlling Strength; 17.3.1.2 D.A.1.2 Table 3 Lesser.ot n�N�,and �N� -� 4,914 �bs Step 6: Convert to ASD based on 1:6 (0.60)+1.2(0.40)=1.44 fi0°h L'+ve Load and 40% Dead toad: d,99*i — --- 4.2.1 T�wwawa,nso= 1.44 -3.4121bs FIGURE fiREXAdY1PLE CALCULATiON C22 City of Tukwila Allan Ekberg, Mayor Department of Community Development Jack Pace, Director July 28, 2016 DAVID GLASSMAN 1309 POST AVE TORRANCE, CA 90501 RE: Correction Letter # 1 DEVELOPMENT Permit Application Number D16-0198 BURLINGTON COAT FACTORY - 17480 SOUTHCENTER PKWY Dear DAVID GLASSMAN, This letter is to inform you of corrections that must be addressed before your development permat can be approved. All carrection requests from each department must be addressed at the same time and reflected on your drawings. I have enclosed comments from the following departments: BUILDING DEPARTMENT: Allen Johannessen at 206-433-7163 if you have questions regarding these comments. • (GENERAL NOTE) PLAN SUBMITTALS: (Min. size ] 1x17 to maximum size of 24x36; all sheets shall be the same size. New revised plan sheets shall be the same size sheets as those previously snbmitted.) (If applicable) "STAMP AND SIGNATURES" "Every page of a plan set must contain the seal/stamp, signature of the licensee(s) who prepared or who had direct supervision over the preparation of the work, and date of signature. Specifications that are prepared by or under the direct supervision of a licensee shall contain the seal/stamp, signature of the licensee and the date of signature. If the "specifications" prepared by a licensee are a portion of a bound specification document that contains specifications other than that of an engineering or land surveying nature, the licensee need only seal/stamp that portion or portions of the documents for which the licensee is responsible." It shall not be required to have each page of "specifications" (calculations) to be stamped and signed; Front page only will be sufficient. (WAC 196-23-010 & 196-23-020) (BUILDING REVIEW NOTES) 1. Building codes referenced in the plans, including engineer's calculations reference 2012 IBC codes. As of July 1 2016, City of Tukwila requires all plan designs with notes to comply with the new adopted 2015 International and Washington State Building codes. Please provide new plans and documents to reference the current State and International codes including 2015 Washington State code amendments as follows: 2015 International Building codes (IBC) 2015 International Residential codes (IRC) 2015 Uniform Plumbing codes (UPC) 2015 International Mechanical codes (IMC) 2015 National Electrical codes (NEC) 2015 Washington State Energy codes (WSEC) 2014 Liquefied Petroleum Gas Code (NFPA 58) 2015 National Fuel Gas Code (NFPA 54) (for LP Gas installation only) 2015 International Swimming Pool and Spa code 2009 ICC/ANSI A 117.1 (barrier free codes) Please address the comments above in an itemized format with applicable revised plans, specifications, and/or other documentation. The City requires that two 2 sets of revised plan pages, specifications and/or other documentation be resubmitted with the appropriate revision block. 6300 Southcenter Boulevard Suite #100 • Tukwila Washington 98188 � Phone 206-431-3670 • Fax 206-431-3665 In order to better expedite your resubmittal, a'Revision Submittal Sheet' must accompany every resubmittal. I have enclosed one for your convenience. Corrections/revisions must be made in person and will not be accepted throu�h the mail or by a messen�er service. If you have any questions, I can be reached at 206-431-3655. Sincerely, ` �� Bill Rambo Permit Technician File No. D16-0198 6300 Southcenter Boulevard Suite #100 • Tukwila Washin�ton 98188 � Phone 206-431-3670 � Fax 206-431-3665 f July 29, 2016 City of Tukwila Department of Community Develapment 6300 Southcenter Blvd, Suite #100 Tukwila, WA 206.431.3670 Re: Correction Letter #1 Develapment Permit Application #: D16-0198 Burtington Coat Factory — 17480 Southcenter Pkwy Allen Johannessen In regards to your structuraf review comments from July 29, z016; we offer the following response: BUILDING REVIEW NOTES 1. Changed International Building Code form 2012 to 2015 on page 3 of the calculations and on sheet S1 of the plans. This will not affect the current design ar calculations. Shoufd you have any questions or concerns, please contact us directly at 972-283- 5111. Sincerely, Jd�'. Hill, P. E. President JPH:CD r��oo • wa �y��t`1���� s ' N� 'yo•: �, _: . p '; .g ,�1-47�23_ rw (a—i�� •�"/�.I-� ��'�'�� �,Z�..u,�c. JOE P. HILL, P.E. CONSULTING STRUCTURAL ENGINEERING 1801 N. Hampton Rd., Suite 440 DeSoto, TX 75115-2399 972-283-5111 ���� �i�K�NILP, �l�'�' ��� 2 9 2016 r�E���� C��TER V Q 1'] �iG V i�fi� �r�� � f PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: D16-0198 DATE: 07/29/16 � PROJECT NAME: BURLINGTON COAT FACTORY SITE ADDRESS: 17480 SOUTHCENTER PKWY Original Plan Submittal X Response to Conection Letter # 1 DEPARTMENTS: �S �� �.- --1 �P Building Division Revision # before Permit Issued Revision # after Permit Issued Fire Prevention � Planning Division ❑ Public Works � Structural � Permit Coordinator � PRELIMINARY REVIEW: DATE: Og�02/16 Not Applicable � Structural Review Required � (��.o approva.1/review required) REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: DUE DATE: OgI3O�16 Approved ❑ Approved with Conditions � Corrections Required � (correctrons entered iri Reviews) Notation: REVIEWER'S INITIALS: Denied � (ie: Zon.ing Issues) I_�7s111��A Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: ivisizm3 PERMIT COORD COP� PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: D 16-0198 DATE: 07/20/16 PROJECT NAME: BURLINGTON COAT FACTORY SITE ADDRESS: 17480 SOUTHCENTER PKWY X Original Plan Submittal Response to Cor�•ection Letter # DEPARTMENTS: ,,�- �anr jZ �a�-c�° Building Division � Revision # Revision # ,��1 �- ���� � � Fire Prevention � before Permit Issued after Permit Issued Planning Division ❑ Public Works ❑ Structural ❑ Permit Coordinator � PRELIMINARY REVIEW: DATE: 07/21/16 Not Applicable ❑ Structural Review Required ❑ (no approval/r•eview required) REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: DUE DATE: OgI1gI16 Approved ❑ Approved with Conditions ❑ Corrections Required � Denied ❑ (corrections entered in Reviews) (ie: Zoning Issues) Notation: REVIEWER'S INITIALS: DATE: Perinit Center Use O�:ly CORRECTION LETTER MAILED: ��� v _ �,� Departments issued corrections: Bldg � Fire ❑ Ping ❑ PW ❑ Staff Initials: iznanoia ALEGIS RESTORATION INC Hume Fspaiiol Contact Safety & Health UVashington State t?epartment of �abvr 8c industri�s ALEGIS RESTORATION INC Owner or tradesperson Principals JONES, BARRIE GLYN, PRESIDENT PRICE, MICHAEL RAY, VICE PRESIDENT PRICE, MARK ALLEN, SECRETARY EVERTON, ROBERT K, TREASURER . Doing business as ALEGIS RESTORATION INC WA UBI No. 603 110 139 License Page 1 of 2 Search L&I �� � ' r A-%.Index fIelp 34} I.�:I Claims & Insurance Workplace Rights Trades & Licensing 3701 S Nortolk St, Ste 300 SEATTLE, WA 98118 206-725-0385 KING County Business type Corporation Governing persons BARRIE GLYN JONES MARK A PRICE; MICHAEL RAY PRICE; ROBERT K EVERTON; Verify the contractor's active registration / license / certification (depending on trade) and any past violations. Construction Contractor Active. ........................ Meets current requirements. License specialties GENERAL License no. ALEGIRI890K6 Effective — expiration OS/19/2011— 05/19/2017 Bond _.... Travelers Cas and Surety Co of America Bond account no. 105904136 Received by L&I 04/29/2013 Bond history Insurance United Specialty Insurance Com Rolicy no. BV01663687 Received by L&I 07/01/2016 $12,000.00 Effective date 05/16/2013 Expiration date Until Canceled $1,000,000.00 Effective date 06/28/2016 https://secure.lni.wa.gov/verify/Detail.aspx?UBI=603110139&LIC=ALEGIRI890K6&SAW= 8/3/2016 � I �� ��� �� ` LAND RD WNER ' PLUMBING ENGINEER: c� � LO (O ) STRUCTURAL ENGINEER: U � -, KIMCO REALTY LUND OPSAHL JET INDUSTRIES �� I BELLEVUE, WA 98006 SE #F4 i201 FIRST AVENUE SOUTH, SUITE 310 1935 SILVERTON RD. L� � � P: 425.373.3905 SEATTLE,' WASHINGTON 98134 SALEM, OR 97301 �� ° ATTN: TIM HAMANN P: (206) 402-5156 P: 503.798.4401 �� � ;TTN: ADAM SLIVERS ATTN: HAL SPENCE °' � 3 E: THAMANN@KIMCOREALTY.COM E: HAL.S JETINDUSTRIES.NET ��� � F: ASLIVERS@LUNDOPSAHLCOM @ c� � � N�� TENANT � � � N � � BURLINGTON STORES, INC. MECHANICAL ENGINEER: a� L Q N�' � � 4287 ROUTE 130 SOUTH ELECTRICAL ENGINEER: � Q� N�� E D G E W A T E R P A R K, N J 0 8 0 1 0 °,1ET INDUSTRIES L Q� d- cv N 1935 SILVERTON RD. JET INDUSTRIES Q �, co co � P: 609.387.7800 EXT. 71180 �ALEM, OR 97301 1935 SILVERTON RD. ��� N�.3 s F: N/A ' P: (503) 363-2334 SALEM, OR 97301 � � � �- � � ATTN: DEAN DIPALO ����: �!M COOK P: (503) 363-2334 E: DEAN.DIPALO@BURLINGTONSTORES.COM � c- ATTN: DAVID ROOT P.E. a E. JIM.C@JETINDU� fRIES.NEI" - ARGHITECT E: DAVID.R@JETINDUSTRIES.NET VI i JJW ARCHITECTS AND PLANNERS, LLC LIGHTING - 5628 AIRPORT WAY SOUTH, SUITE 112 �;, CARMEN BLAKELY SEATTLE, WA 98108 E: CARMEN.B@JETINDUSTRIES.NET P: 206.420.2242 � � F: 206.260.9595 , ATTN: DAN RASMUSSON � E: DRASMUSSON@JJWARCH.COM ������� �����/ . �I�I�I�� �� ���� ' ��� ��'�� �II ����� � ��� jt � d � APPLICABLE CODES Q � � 1. FLAME SPREAD & SMOKE DEVELOPED RATINGS: 2012 INTERNATIONA� BUI�DING CODE 2008 NATIONAL ELECTRICAL CODE (NEC) `..o � ; �� f NFPA 70 � � � 1.a. ALL FINISHES TO BE AS NOTED & SHALL NOT HAVE SMOKE DEVELOPED RATINGS GREATER THAN 450. (�B�) ( ) � 1.b. INTERIOR FINISHES OF WALLS & CEILINGS IN ALL ROOMS OR ENCLOSED SPACES SHALL HAVE A CLASS C FLAME SPREAD INDEX 76-200; SMOKE DEVELOPED + WAC 51-50* + PART f A���D PART 3, 2009 � �� � 3a + O R D. 6 1 1 3, C H A P. 2 3. 0 5 & 2 3. 1 0"* W A S H I N�� T O N C I T I E S E L E C T R I C A L � � INDEX 0-450. INTERIOR FINISHES OF EXIT ENCLOSURES & EXIT PASSAGEWAYS SHALL HAVE A CLASS B FLAME SPREAD INDEX 26-75; SMOKE DEVELOPED INDEX i� _�� � _�� ..}_�� + ICC A117.1-2009 ACCESSIBLE AND CODE***�; o � 0-450. ASTM E 84. IFC TABLE $03.3. � ���,����� ��;,r�., �� � `�� �� fi � ��r���t�,��c����r�.�." -swt�ih�= � � � � ��.. `�� � ' � `� ��: ����vri�k�e'S�St�uK�n� �� � ' � `� ��� USABLE BUILDINGS AND FACILITIES 2012 INTERhdATIONAL MECI-�ANICAL CODE � �� k � 1.c. MATERIALS USED AS INTERIOR TRIM SHALL HAVE A MINIMUM CLASS C FLAME SPREAD & SMOKE DEVELOPED INDEX & SHALL COMPLY WITH ASTM E 84. �� ,���'� �`�Y�4� ���.,� N l�"� � r 2012 INTERNATIONAL RESIDENTIAL CODE (IMC ' � � �,,, �,-� , ,�€•��.; � �.:� ,�" > � * �''.,. o �,s �� �� � „ � �.. � I RC + WAC 5 , -52 � COMBUSTIBLE TRIM SHALL NOT EXCEED 10 /o OF THE AGGREGATE WALL OR CEILING AREA IN WHICH IT IS LOCATED (IFC 804). ��.--� �� ��� �� y -� ( ) �.� �. ..g.. �- k �,.{; �� �-� ,� � _ � ' ' - s�a �, � , . � ..��` ; � � . : + WAC 51-51 * + ORD. 6�S 13, CHAP. 23.50** � 1.d. INTERIOR WALL & CEILING FINISHES SHALL COMPLY WITH NFPA 286 TESTiNG MEASURES. iNTE�IOR FLOOR FINISHES SHALL COMPLY WITH NFPA 253 WITH A y ���,� - �, � + ** 2012 WTERPyATIONAL NATIONAL FUEL ' ORD. 6113, CHAP. 23.12 � � CLASS 2 CRITICAL RADIANT FLUX > 0.22 WATTS / CM2. FLOOR FINISHES IN EXIT / ACCESS CORRIDORS SHALL BE CLASS 1 CRITICAL RADIANT FLUX > 0.45 WATTS - s,s���,� ' �; �$µ ~_'�' ° Q 2012 WASHINGTON STATE ENERGY CODE AND GAS CODE (IFGC) / CM2. 'r� �„� � ��� �� o � (WSEC) + WAC 51-52-21000 � � 4Ye tfizic�5r�taihc�nteP r, � n � x * 1.e. INTERIOR FINISH MATERIALS SHALL BE APPLIED SO THAT THEY WILL NOT BECOME READILY DETACHED WHERE SUBJECTED TO 200 DEGREES F. FOR NOT LESS ���. ��'��,�,', �� � ��� ��� �� � + WAC 51-11* 2012 UNIFORM P�uMBING CODE (UPC) ,� � � � � �� -s,6�,,s�- s�Fa.�,st �� : _ � �� �� � �- � � ' 2012 INTERNATIONAL FIRE CODE IFC + WAC 51-56* � THAN 30 MINUTES (IFC 803.2). �� � �� � '�� .� � � _ � -`� ������s� � � 1.f. THE REQUIRED FLAME SPREAD OR SMOKE DEVELOPED INDEX OF SURFACES IN EXISTING BUILDINGS MAY BE ACHIEVED BY APPLICATION OF APPROVED FIRE ��'�'�`�`�` ' �� � -� "' + WAC51-54A* + ORD. 6113, CHA,P. 23.60*:* = w,r� + ORD. 6114, CHAP. 23.11*** RETARDANT COATINGS & SHALL COMPLY WITH NFPA 703 (IFC 803.4). �}6����: � �-�� - � 2. ALL ELECTRICAL WORK SHALL CONFORM TO LOCAL CODES, THE REQUIREMENTS OF THE NATIONAL ELECTRICAL CODE, & NFPA 72. s�- st�o;f,s2 �� � � OCCUPANC`( CLASIFICATION ��� � "�r�} S.t�a(=tl:�irT�i'� Z ' 3. THE CONTRACT WORK SHALL INCLUDE FURNISHING ALL MATERIALS, EQUIPMENT, T04LS, LABOR & SERVICES NECESSARY F�R COMPLETION OF THE PROJECT. ;� �;� �� �. �� ; �i�� s�arsa:ast 4. THE G.C. SHALL PERFORM ALL WORK IN CONFORMITY WITH THOSE LAWS HAVING JURISDICTION WHETHER OR NOT SUCH WORK IS SPECIFICALLY SHOWN ON � � ,�', �`��"��Fefs:'� CLASSIFICATION ACTUAL SF NET SF/PERSON TOTAL OCCUPANCY THESE DRAWINGS, INCLUDING ALL SEISMIC REQUIREMENTS. THE G.C. SHALL PROCURE & PAY FOR ALL NECESSARY BUILDWG PERMITS & SHALL BE REIMBURSED � 5������ � �� � � M MERCHANTILE 38,481 SF 3� SF/F'ERSON 1,284 PERSONS FOR GENERAL BUILDING PERMIT COSTS BY OWNER. BUSINESS LICENSE COSTS ARE NOT REIMBURSABLE. '�� � O 5. THE G.C. SHALL BE RESPONSIBLE FOR THE QUALITY OF WORKMANSHIP & FOR COMPLIANCE WITH THE DESIGN. THE G.C. SHALL CORRECT ALL ERRORS & t�� � s � �"X FLOOR AREA (SF): INTERIOR + EXTERIOR ALTERATIOi� ONLY - NO ADDED OVERALL AREA � � E�rsc -bv �� :st�t-�Tst�t -� ���� DEVIATIONS AS REQUESTED BY THE OWNER. "` �'� ' , , :, � : � , �' C° � �' �. � ` , , �ICEa seatcle w 6. G.C. SHALL BE RESPONSIBLE FOR QUALITY OF ALL REFURBISHED MATERIALS. ALL REFURBISHED MATERIALS TO APPEAR NEW. ��� ,�� ��� � �:�`��''f�st '�~i'�j � �;���,y5k CONSTRUCTION TYPE � � �, �, �� .� �.` 7. THE G.C. SHALL PROVIDE & INSTALL FIRE EXTINGUISHERS PER CFC STANDARD 10-1 :e�� � � � � ' 8. ALL WOOD BLOCKING, STUDS, PLYWOOD, ETC. TO BE FIRE RETARDANT. � '� � �� � � � �� -� � " � `" �� � ���`'" ���'� `-= �-�� � ` � � �� � -� � ��� � � � � � �,.,�, :� � �� �;�� CONSTRUCTION TYPE VB - FULLY SPRINKLED �' � - ��, .� �'�-�t,��T ELEVATIONS, ANGLES, & EXISTING CONDITIONS BEFORE PROCEEDING WITH THE AFFECTED ORK & �� 4 �R` NUMBER OF STORIES - SINGLE STORY ��°a��-;y =-�� �'��: 9. AT THE TIME OF SUBMITTING FINAL BID, THE G.G SHALL VERIFY ALL RELEVANT DIMENSIONS, f�� ��� � � � �,� ¢ NOTIFY THE ARCHITECT OF ANY DISCREPANCIES IMMEDIATELY. ALL DISCREPANCIES SHALL BE RESOLVED PRfOR TO PROCEEDING WITH AFFECTED WORK. �� ��°' � -- - � � �'.;.-..:.�.-r�,.�-� 10. THE G.C. SHALL CONTACT THE OWNER / TENANT IMMEDIATELY IF THEY ENCOUNTER ANY HAZARDOUS MATERIALS. ���t� s�- `� � ��-°=-. t� = ° ��`� DEMISING WALLS: 1 HOUR RATED � � _,'� � , � � �� �f � '' MECHANICAL ROOM WALLS 1 HOUR RATED � 11. EXACT LOCATIONS OF PIPING, DUCTWORK, CONDUIT & FIXTURES SHALL BE COORDINATED BETWEEN CONTRACTORS & SUBCONTRACTORS TO AVOID INTERFERENCE. - �, �`�} `�-� ����� < = ^ � � �-..� 12. EXISITNG SPRINKLER SYSTEM SHALL BE MODIFIED. HEAD REPLACEMENT TO MEET ALL LOCAL & NATIONAL CODES INCL. NFPA-13. � `�' �- �" 13. EACH CONTRACTOR SHALL COORDINATE ARCHITECTURAL DRAWINGS WITH THE PLUMBING, MECHANICAL & ELECTRICA� �if�AWINGS & ALL SPECIFICATIONS BEFORE PROCEEDING WITH THE WORK & BURLINGTON COAT FACTORY PARKING � PARKWAY SUPERCENTER NO ADDED OVERALL FLOOR AREA - NO CHANGE TO EXISTING COUNT �,,, �'" �`��' SHALL NOTIFY THE ARCHITECT OF ANY DISCREPANCIES OR CONFLICTS IMMEDIATELY. ALL DISCREPANCIES SHALL BE RESOLVED PRIOR TO THE CONTRACTOR PROCEEDING WITH AFFECTED WORK. ��4so souTHCENTER PaRKwaY k�T $ f'°::'�� ���' . 14. SHOULD ANY OF THE DETAILED INSTRUCTIONS ON THE DRAWINGS CONFLICT WITH THE NOTES OR SPECIFICATIONS OR WiTH EACH OTHER, THE STRICTEST PROVISION SHALL APPLY. TUKwi�a, WA 98188 15. ADDITIONAL WORK, IF APPLICABLE, MUST BE AUTHORIZED IN WRITING BY BOTH THE BURLINGTON CONSTRUCTION PROJ��T MANAGER & ARCHITECT AFTER THE FORMAL REQUEST FOR INFORMATION Q� ����� �� � • (RFI) PROCESS HAS BEEN COMPLETED (GC ISSUES AN RFI TO THE ARCHITECT, IF THE CLARIFICATIONS AND / OR SUPPLEMENTAL INFORMATION INVOLVE AN ADJUSTMENT IN THE CONTRACT SUM, THE ,J � �` ARCHITECT SHALL ISSUE A WORK CHANGE PROPOSAL REQUEST TO THE G.C. TO �BTAIN PRICE QUOTATIONS NEEDED �JR NEGOTIATING CHANGES IN THE C�NTRACT FOR CONSTRUCTION). �- z I 16. JOB SITE CLEANING: DURING DEMOUTION & CONSTRUCTION, THE JOB SITE & BUILDING INTERIOR SHP,LL BE CLEANED ON A LAILY BASIS, INCLUDING REMOVAL OF TRASH, RUBBLE, DEBRIS & , �'. z`__ . R O R G A N I Z A T I O N O F M A T E R I A L S & E Q U I P M E N T. U P O N C O M P L E T I O N O F T H E W O R K, T H E J O B S I T E & B U I L D I N G I N T E R I O R S H A'_ L B E T H O R O U G H L Y C L E A N E D, I N C L U D I N G A R E A S O F T H E B U I L D I N G M A D E NOT TO SCALE .. , DIRTY BY CONSTRUCTION WORK. THE G.C. SHALL REMOVE TRASH, RUBBLE, TOOLS, EQUIPMENT & EXCESS MATERIALS FRiaM THE PREMISES. THE BUILDING IS TO BE LEFT IN PERFECTLY CLEAN ' "`'"` CONDITION. �� � �� A � ' . 17. G.C. IS TO PROVIDE SUPERVISION OF ALL TRADES / SUBS (INCLUDING THOSE HIRED BY BURLINGTON) AS WELL AS ON-SI"fE.SUPERVISION UNTIL THE STORE'S GRAND OPENING. G.C. & E.C. TO BE ON - SITE GRAND OPENING DAY IN CASE OF EMERGENCY. � � � � � � � ' �' � 18. STAGING AREA WILL BE CONTAINED TO AN AREA AS DICTATED BY THE BURLINGTON PM. -�! 19. G.C. IS REQUIRED TO HAVE 30-YARD DUMPSTERS AVAILABLE DURING CONSTRUCTION & THROUGH THE FIXTURE INSTALL PROCESS , AT A LOCATION APPROVED BY THE LANDLORD, MALL OR OWNER. PARCEL ID: 262304-9110 � 20. MAINTAIN A CLEAR AND UNOBSTRUCTED PATH TO EXITS. NEW EXIT CORRIDOR TO BE COMPLETED F�RIOR TO CLOSING OFF COMMON MALL AREA FOR NEW WORK. REV►StONS �o ch�►���; �.�-,� ZONING: TUC - TUKWILA URBAN CENTER , F, � b^ r�nde to the scc�pe 21. PROVIDE WORK AND MATERIALS IN ACCORDANCE WITH APPLICABLE CITY, COUNTY, AND LOCAL BUILDING AND FIRE CODES AS REQUIRED. IN CASE OF CONFLICT ` of °-�:: t,- � F-� �,� n PORTION OF SE 1/4 OF SW 1/4 - BEGIN NE CORNER TH S C�-1''-�5 W TO SE CORNER OF SW � ����-=ov�i of WHERE THE METHODS OR STANDARDS OF INSTALLATION OF THE MATERIALS SPECIFIED DO NOT EQUAL OR EXCEED THE REQUIREMENTS OF THE LAWS OR �� �- f '`� -� �J �?��;;,��_ ORDINANCES, THE LAWS OR ORDINANCES ARE TO G�VERN. NOTIFY ARCHITECT OF CONFLICTS. �� 1/ 4 T H W L Y AL O N G S L I N E T O A L I N E 6 F E E T D I S T A N T N E L Y M E A S A T R/ A F R O M E L Y ������� � -�� .., �-� a� �� I \7130115KIR , tt! f� s:,�, (��'.',/ t�n submit±ai � 22. WORK IS GOVERNED BY CONDITIONS AS INDICATED IN CONTRACT DRAWINGS AND SPECIFICATIONS �OR BUILDINGS. � �, AREA OF WORK MARGIN OF SOUTHCENTER PARKWAY TH NWLY ALQtiG SAID LINE TO POINT WLY OF POINT �� r' �l ��i�.--�' 4�'� :s��►�1 p;an revi�5� fE2s. ! 23. DRAWINGS AND SPECIFICATIONS: STRUCTURAL, PLUMBING MECHANICAL, ELECTRICAL AND FIRE PRUTECTION ARE SUPPLEMENTARY TO THESE DRAWINGS. � ;� OF BEGINNING TH ELY TO POINT OF BEGINNING LESS PORTION IN MINKLER BLVD ' �!; , NOTIFY ARCHITECT OF DISCREPANCIES BETWEEN THE CONSULTANTS' DRAWINGS WITH A WRITTEN REQUEST FOR CLARIFICATION. WORK INSTALLED IN CONFLICT �. -: WITH THESE DRAWINGS OR SPECIFICATIONS IS TO BE CORRECTED BY THE CONTRACTOR AT NO EXPENSE TO THE OWNER, TENANT, OR ARCHITECT. -a � �' __` _ . ' � �_, _. : , . _. __ _ _ -: : ., ... -- ,_ .: r esdayMorning � I Tu . _. � 24. VISIT JOB SITE AND VERIFY FIELD DIMENSIONS AND CONDITIONS AND NOTIFY ARCHITECT OF DISCREPANCIES BEFORE PROCEEDING WITH WORK. � � --------� 25. OBTAIN PERMITS AND APPROVALS REQUIRED. o,� �' `` HomeF=��S ����,�x � cost �� o David�s ; maCy's F; � �Y �� L� �� I I_ D I � P E I� IT �TE� 26. WALLS ARE TO BE INDEPENDENTLY SUPPORTED FOR SEISMIC CONDITIONS IN BUILDING JURISDICTIONS WHERE APPLICABLE. m�; o:s�r.� vo ,. ` J���;` �� 26,2"5` ,�ooS ` 25,,6nf m Br'da� F°�"'t°�eca°ery ` j t L i , zs,tacsi .�' � y �t� c`�chae�S n�nv�anl ',' � �!� , ; ; �+ (� [� �, , � �;s�f � ZH,Z5z5i 4o,00asf r 79,��� �;: ,,� �f �� -------------�---_ .--_t294�`____�__ __°��fi'�5' ; R HITECTUAL = SEE SPECIFIC SHEET FOR MORE INFORMATION 27. PROVIDE AUDIBLE AND VISUAL ALARMS PER CODE. THESE ARE TO BE OPERATIONAL IN NEW EXIT CORRID R PRI R T L IN FF MM N MALL AREA F - Q - �,�.. e<; I A C ( O O O � Ot7 � O l�O O Of � r ,� .., a : . '��� . �� 12,793sf �� . ��� �fp�/f�,'f,'� � a,. . - NEW WORK. C� ' � .��. �_� . - -- -- ;-=--- -: ' --_ __ __; �; p �`� ��`/,��� " ' ' ' ' � �_ - ALL SYMBOLS ARE NOT NECESSARILY USED) C •_` _ � _-'_- y yl � - _ _ � �.- � � _ __ __ . ��.. , 40005t : AmericasBest - � �- d °' =-� - ; • 28. PROVIDE SPRINKLER SYSTEM IN NEW CORRIDOR PER NFPA 13 PROVIDE SPRINKLER STANDPIPE TO NEW TENANT SPACE. COMPLY W/ TENANT FIRE PROTECTION � __ =- _= -�-� Y�-, .-� w� ` � Z=Zos� �": s�eeP S9�Sf -= � � �'� ° ° � � soao�r � � � i .❑ � � -, Hotiby Town i, - - � ;; - - o ' d T� .�- � ' s�s�5r Lifewa Christian St m� CRITERIA AS NOTED ON THIS SHEET. �-eacna�gaaYwo�ks, _ � . '. i . � R �� 924s --- _ ' �f..: _. _ __. ._�_. .. � _ �1- _. _ - ' ' - _ � ' - '�_ _ �= �. , q c' .. Famous Daves ezao:r f � -. -' ' ; y ore -.- - - - -- 29. PROVIDE FIRE TREATED WOOD OR EQUIVALENT SHEET METAL BLOCKING REQUIRED FOR WALL AND CEILING MOUNTED ITEMS ' � a ' -- �" l � � I j i � �� � .-: _ ,�- � J �. � � � . � ; Ulta Cosmetics `-- - , - �_ _ _ _'; --�� _ _ 30. DAMAGE DUE TO ADJACENT WORK BY CONTRACTOR OR CONTRACTOR S FORCES ARE TO BE REPAIRED AT CONTRACTOR S EXPENSE. �,,,8�55f i _ __: �� _ : _. �- j _ ' ": ` ,�! /�`__/ � - SprmtPCS ; � 31. ASSUME PIPES, CONDUITS, VENTS, ETC. TO BE EXPOSED, UNLESS NOTED AS FURR AND FINISH ON CONSTRUCTION DRAWINGS. 200o�s ; rna�Ma�� 2°°°5� ;,;_ Stanford�s . - � ;, „ :-- �- 169 DOOR NUMBER ' I i Capriotti's Sandwich Shop_ Bar & Griil W�ng Stop z000st - ;� ! � ..� i � � ' - ry � � Paufic Dental ssoost " � ; ! 32. INVESTIGATE AND VERIFY LOCATIONS OF STRUCTURAL, MECHANICAL, AND ELECTRICAL ELEMENTS AND OTHER EXISTING CONDITIONS PRIOR TO BEGINNING THE � Rfu Y CotdStoneCreame , �� � ! ! ii BOUOsf � r;�d;;, � ._ ' -. � �; -_ , f r•.\F i'rri.�.^_� WORK. i 92365f , ; _;i " , �enterParkway 169 ROOM NUMBER � 33. DO NOT SCALE DRAWINGS: USE DIMENSIONS SHOWN ON THE DRAWINGS AND ACTUAL FIELD MEASUREMENTS. NOTIFY ARCHITECT OF DISCREPANCIES. _=.. '___�_ --- __�` gou�h -_ - - ---- DEVIATIONS FROM DIMENSIONED LOCATIONS REQUIRE ARCHITECT APPROVAL. ' (,, 34. "ALIGN" MEANS TO ACCURATELY LOCATE FINISHED FACES IN THE SAME PLANE. OFFSET STUDS WhtRE REQUIRED TO ASSURE FLUSH WALLS AT COLUMNS. � B WINDOW TYPES ������ �o �J� ��j i' � Q 35. COORDINATION: VERIFY AND COORDINATE THE WORK OF TRADES TO ASSURE COMPLIANCE WITH THL DRAWINGS AND SPECIFICATIONS. � � � � F' �' �j=� f� ����f i� �tt '� fo e�rs �nd or:��i��io��. 36. NOTIFY ARCHITECT, IF INFORMATION IN THE DRAWINGS IS INCOMPLETE OR IN CONFLICT, FOR CLARIFICATION. 1� KEY TO WALL FINISH SCHEDULE �-,� ,_,� r z__:.r z• � � ....� `, �. �:� � .?��� �������t�s ��� ��� ������?� Q 37. UNLESS NOTED OTHERWISE, ALL DOORS ARE TO BE LOCATED AT 4" FROM INSIDE FACE OF PARTITION TO EDGE OF DOOR JAMB. (HINGE SIDE ONLY) I �� � ._T ,T � � �.� �; �c��ie� ��� �� ����r��t�. ����i� °t 38. ANY REFERENCE MADE TO CONTRACTORS, INCLUDING BUT NOT LIMITED TO L.L.C., G.C., OR E.C., IN�ICATES WORK WHICH IS THE SOLE RESPONSIBILITY OF THE OB KEY TO FLOOR FINISH SCHEDULE . s,.� `' U W Q LANDLORD'S GENERAL CONTRACTOR UNLESS SPECIFfCALLY NOTED. � _ , . . . � ��y " �'� "��'� ��� ���L"�°�=�� �� �w�+���=��d: Q z 0- 39. PUBLICLY ACCESSIBLE PORTIONS OF THE BUILDING INCLUDING SIDEWALKS, ENTRY RAMPS, AND EXIT DOORS SHALL COMPLY AT A MINIMUM WITH THE AMERICANS � � � Z= ' ������ � LL W�. � WITH DISABILITIES ACT, TITLE III, AND LOCAL ARCHITECTURAL BARRIER BOARDS. � �� O KEY TO CEILING FINISfl1 SCHEDULE �;: „ ��" � U W J p D�de: __ �/� � l,� � I- 00 40. DETAILS REFERRED TO AS "TYPICAL" SHALL BE CONSIDERED AS A TYPICAL CONDITION REPEATED TH�OUGHOUT THE PROJECT, WHETHER REFERENCED OR NOT. NOT TO SCALE � Z j O� z p� p 41. CONTRACTOR TO COORDINATE TENANT SHELL PACKAGE WITH TENANT T.I. DRAWINGS TO LOCATE BLOCKING OR PLYWOOD SHEATHING. D KEY TO WALL TYPES � W � W� L� Cit�j/ �` ��$i�lia� � �..� GENERAL TEiV�4NT FIRE SUPPRESSION DESIGN CF�IiEf�IA: BU��`D��°'���� w z�_�> 1. FIRE SPRINKLER DRAWINGS FOR THE SITE AND BUILDING CONSTRUCTION AND ANY OTHER ASSOCIATED LANDLORD WORK SHALL BE SUBMITTED AND REVIEWED MATERIAL KEY & GRAPHIC ABBREVIATI�NS � .- COLUMN CENTERLINE' . = O��> BY THE TENANT ARCHITECT CONCURRENT WITH THE LANDLORD'S SUBMISSION OF THE DRAWINGS TO THE LOCAL AHJ. � C7 Q O� AB ANCHOR BOLT FD FLOOR DRAIN SF SQUARE FEET ` � 7���I 2. LANDLORD'S FIRE SUPPRESSION CONTRACTOR IS RESPONSIBLE FOR OBTAINING ALL PERMITS AND INSPECTIONS FROM THE LOCAL AHJ FOR THEIR OWN SCOPE a,cT ACOUSTICALCEILING FE FIREEXTINGUISHER SPECS SPECIFICATIONS L GROUT MORTAR BRICK TILE FIN FINISH STRUC75TRUCTURAL � � �� O� OF WORK. � � ADJ ADJUSTABLE FM FACTORYMUTUAL STL STEEL AFF ABOVE FINISH FLOOR FR FIRE RATED SS STAINLESS STEEL A_� SECTIO�! MARK �� �� 3. LANDLORD IS REQUIRED TO PROVIDE ELECTRICAL CONNECTIONS FOR THE FIRE ALARM MONITORING SYSTEM FROM ALL EXTERIOR PIV AND SHUT OFF VALVES ALT ALTERNATE FRT FIRERETARDANT T/BM TOPOFBEAM ���g��p ��� PLYWOOD CONCRETE BLOCK ALUM ALUMINUM TREATED TEMP TEMPERED � ���� TO THE BUILDING (TO BE LOCATED BY THE TENANT ARCHITECT AND SUBJECT TO THE AHJ). � � ARCH ARCHITECTURAL Fs FLOORSINK TG TRUSSGIRDER 5 ��i�� �C3S�1�'LIA�C� � m� ��- BJ BARJOIST FV FIELDVERIFY T&G TONGUEBGROOVE ���g��q��� 4. ANY SPRINKLER HEADS PLACED BY LANDLORD SHALL BE PER TENANT STORE LAYOUT PLANS AND BE IN COMPLIANCE WITH LOCAL CODE REQUIREMENTS. � � BLDG BUILDING �rc FOOTING TIJST TOPOFJOIST ENLARGED PLAN/ �"� �`� � �� RIGIDINSULATION STEEL BLK BLOCK GA GAUGE TIST TOPOFSTEEL A_� � DETAIL R�FERENCE SPRINKLER HEADS IN EXPOSED FINISHED SOFFITS, CANOPIES, RECEIVING POD, DRYWALL CEILINGS, AND FINISHED CEILINGS BELOW 11 -0 WITH VIEW OF BLK�c BLOCKING GALV GALVANIZED roM TOPOFMASONRY I A�� p 2��16 DATE REVISION THE PUBLIC SHALL HAVE SEMI RECESSED FLUSH HEADS. BAnoRB�aNKET •.� � BM BEAM GP GUARDPOST TOS TOPOFSLAB I -CONSTRUCTIONSET INSULATION •••' CONCRETE BRG BEARING GWB GYPSUM WALL BOARD nP nPicA� fj 03-10-16 5. LANDLORD SHALL FURNISH TO TENANT AN APPROVED 5-YEAR CERTIFICATION FOR ANY SPRINKLER SYSTEM COMPONENTS THAT LANDLORD INSTALLS. � BTM so�noM HM HONLOWMEfAL uNo OTHERWSEED LY�' � RECEIVED � '�+ �}^c CITY OF TU�WILA EXISTINGCONSTRUCTION � REVISIONINDICATOR C/C CENTERTOCENTER HR HOUR VT TILE � 4„s��y� (�j i(,Eii�F�Ii��' � 6. ALL FIRE PIPING SHALL MEET THE MINIMUM STANDARDS OF A CORROSION RESISTANCE RATIO (CRR) OF 0� CJ CONTROLJOINT HT HEIGHT vcr VINYLCOMPOSITION 3 �U6�����,��J�I�� i::� � NEWCONSTRUCTION CKT CIRCUIT HVAC HEATING,VENTILATING, TILE ELEVATIO�� KEY � 1.0 OR GREATER. � RODBSEALANT CLG CEILING AIRCONDITIONING VWC VINYLWALLCOVERING A-� _" """-"T"" '-"'` JUL 20 2016 COL COLUMN INSUL INSULATION W! WITH Q 7. WET PIPE SPRINKLER SYSTEM IS REQUIRED THROUGHOUT THE INTERIOR OF THE BUILDING. coNc CONCRETE JB JUNCTIONBOX w�o WITHOUT OX DOOR IDENTIFICATION -�5- FLOOR ELEVATION CONST CONSTRUCTION LF LINEAL FEET REV I S I OI�f C LO U D W ITH PEI�II�IT �:E[VTER 8. HOSE RACK SYSTEM: 1-W' HOSE RACKS SUPPLIED FROM SEPARATE RISER (IF REQUIRED)C CONT CONTINUOUS LG LONG ' O GRIDLINE CONTR CONTRACTOR LLH LONGLEGHORIZONTAL REVISION DELTA TAG 9. CONTROL RISERS FROM FLOOR TO ROOF ELEVATION SHALL BE NOT LESS THAN 6" IN DIAMETER. c� CENTERLINE ��v LONGLEGVERTICAL CMU CONCRETEMASONRY MASY MASONRY X UNIT MFR MANUFACTURER REFER TO 10. DESIGN DENSITIES AND AREAS OF APPLICATION AS FOLLOWS: X SECTIONINDICATOR � DETAILINDICATOR AXX AX. CRS COURSE MECH MECHANICAL a. FOR OFFICES, VESTIBULE, CORRIDORS, HALLWAYS, MEN'S RESTROOM, WOMEN'S RESTROOM: LIGHT HAZARD- 0.10 GPM/SF OVER 1,500 SF; MAXIMUM oa D�Ei R MEOT METALRYOPENING DETAIL NUMBER COVERAGE PER SPRINKLER HEAD= 225 SF DIM DIMENSION N�c NOTINCONTRACT � DN DOWN NOM NOMINAL b. ALL OTHER AREAS - STORAGE AND DISPLAY OF CLASS I- IV COMMODITIES ON SHELVES TO MAXIMUM 12'-0" STORAGE HEIGHT (NFPA 13 TABLE 12.1.10.1.1 os DOWNSPOUT Nrs NOTTOSCALE 2 ; AND FIG. 12.1.10) -.20 GPM/SF OVER 1,500 SF ow DRYWALL o�c ONCENTER / DWGS DRAWINGS PL PLATE, PROPERTY LINE SEE 2 A-1 A-1 � EF EACH FACE PR PAIR c. DESIGN AREA SHALL BE THE HYDRAULICALLY MOST REMOTE RECTANGULAR AREA HAVING A DIMENSION PARALLEL TO THE BRANCH LINE AND EQUAL TO �LEC ELECTRICAL Pr PRESERVATIVETREATED EQ EQUAL RA� RADIUS OR GREATER THAN 1.2 TIMES THE SQUARE ROOT OF THE AREA OF SPRINKLER OPERATION. ! EJ EXPANSIONJOINT REINF REINFORCE(ED) (ING) SHEET NUMBER -�- � d. COMBINED HOSE STREAM ALLOWANCE = 500 GPM Ew EACHWAY REP REPRESENTATIVE I EXT EXTERIOR REQD REQUIRED O . o 11. LOWER AND UPPER CANOPY AREAS ARE TO HAVE A SIDE WALL, DRY HEAD FIRE SPRINKLER SYSTEMiUNLESS OTHERWISE DIRECTED BY LOCAL AHJ. 2o�s-29-o0 A 0 � N B........... O � N C 0 N N D ___ O 0 �n N E _ 0 0 O � `n N N � 0 �, N G _._.. 0 � N H O � N O � N Q � L � � 165'-0" , ; 55'-0" ; _ 55'-0" i .. _ . ..... ,.. . . . . � �B7 ..... �-------- ' E17 E17 R42 �Ra2 R42 JAN. EMPLOYEE LOUNGE � EQUIP• - ci ef��-ei: ei c� �ci'�� � ROOM n W. . Q 0 � 1 E13 � E13 . � ,� � R42 � It42 R42 GI GI Gl � EI Gl' f.l � . -. � � W � u� �:. . 6 ( 7 r � qo o � p 3 �' � � -- ---. �'� E� � WOMEN'I C�I '. ASST. MGR./ ES E3 ` EIO `�� RO � � - � W E-LEARN/ LP 'El I E6. �`_, , E8 H8 �E8 ES� MGR.:.:.. d' I .. I� � .... -. � 2� 55'-0" CONT;AINER � P-----► . _ . .... . . . .. . . .. R19.R R19.8 C____� � � � PIXTURE STORAGE � z ��_ � FFiAME E1 � � ( 1 RECEIVING � � � �'�ME E1 '-' 1�� J � W '� Q � V5 : �� �� � � �� C p . . � � =N 1219.N 219.8 R19.8 � : S R42 R42 R42 It42 R42 It42 ILl9.fl R19.N R19.R ' � LAYAWAY � ��.������ 9 630 unit capilClty fi tiTEI' LADI)F.R `T `i y �� G R42 R4� R42 R42 1i42 R42 Q rr,. �� q .r Q � - �, � - �' "' '�'� FRAME E1 - - 'ITTING PAEN'S FITTING / P y� ROOM I�� x • � � �� ��--= , -��•- Ffi3 $ ' _ _ � �'_ - �'^ �.- + �. �.. �.. . _ ` - _ � A R19.9 RI9.8 1219.8 � �a � �.._ . � .. . .. .. ._._ . � _. �` . ..`� � � - � i\vi N � .. . .. . Yl :: YI Yl YI � Yl YI �... YI . �. Yl YI Yl YI YI � I m ll33.... N73 � � � E33 B33 � 637 B14 '_d43 B43 d47 U4) _843 1347 U43 : �..,- . , , , . .. ._ < . . . . ... . . � H75 }q5 k175 H75 H75 H50 H50 .._.."_ � � SiORAGI> � - L4YE7Tt GE HGR .�HOGS 50 .�I S� AC('. IItLS' A(.CLSSOItIl'S ��� oq �� �� F��YS ��('CI:�RIf:.S� s 5"CORAGIi Tltl. H.4�IPI:RS � r; N � � r � s � �. U�°i� s � � s � a � �� m � '2:i T �� � � � � � � ��r x . �m �! S � rei Hens � ci . . . �f � � .� �. � I lll I HJI FI3( 'HJ( � •� x Q..00 B37 d37 D37 . f377 B37 ll7, m I ,,, HI2G H12G H12G t1126 H12G o, -� � . a m I >� F137 637 '. �37 B37 � D37 B37 � 61 �� � � I m°� N N � N N N_ �-= H:8 H28 t12S H23 H?B - j- .' m H.. . DI.4YLIL B.aC U. . M Q a N rv rv I NL I I GG(iAFi1[S ' J T � e H: 9� -- '� ' HATH PO'f"fY 'l " i 1 ., �; °' N y O v,_„ � - SHW It. CUR"I'. SH�\'IL .4CC. ' J � '� �' F.,�� B75 B35 1335 � B35 B35 H77 -.s�+ . °•�` O1 °� � °� °i J O1 �' rv rv x�v N � __ �+ H23 H28 H2R H^_y H29 a, p n m r m �� € �"',, �"'„ �. ", -.� w : w ' ..w � �+- � �u. �.i+. .w �. o s r NN �� ro = HI2 Hi2 III2G H12(+ 1112G = '__ �' C�7. U35 B35 13J5 . D35 B35 .035 ^ O�. p j ,_ r W 1 : O�; � � � V . p { �.�.� y. . Q � N M ' �, H.4'fll L•NS. JA'fH ACC. p� �' n U 13A'I'H IiLAL7'H LLGC. d: x i ' �� y�.' ^�' �O a rv �i j� �v N' F __ ' c¢., _ .� Q SAI'I:T7' ��i I O �� 5 � m O .�' INP. . �; 5�'� y F. p N N F�� � '' NI UA'I'H ILUGJ RUG SG'f5 _' S �'� � u� � PCL•D.61BS I011D.IGLCItv. ���.. e �� ' ; � : � '3�.� p.. y� m p ... y� k13 H7 H3 H21 N21 y _ � � o . . _ �� : <e � � _ � N � � � ,� ��, � P � � � o � �, � - � -� 3 - B36 1336 ��n vi �- . �� a yi oo w � 5 r .. m�I � rn U75� f136.. ...B36 � 1 36 . _ �.3... �. : m w: w o, � m N o r.xn __ .' °° -' °° }°° � > i:. . µ. U� i+. i"' o� w yi w❑ '+. m u.. m m � p� H7 I�II k13 H3 H3 -� �.m m q � .. � o o r: �a� n1� - � ° � � � � 1 x � � N35 ➢35 635 . �35 �35 H35 S a. � v . � m i-.�- � ,o � Q '"y 70N'1:L5 �' g I z_. INPANfPLhDWG NAT. - G a � t� � O 5� ���- O C z ' N si ' e. ai v. si V O 5i O� si � y; `� ' O rv �v �{ N rv __ I HANGING ' � r�e�wc , ti ti�, ❑ q,� q � m m o � � � � E. � �:. ��..- Q C.: . q�` F y �� U N 4 SHGLI'S 13LNK77 UL't51'HRON'S 3 '-�f .. f i q:. ,a":? � K.e m O O.e O �' BII �_ ��.o, H3 H8 111?G H12G H21 o p' _ �' .(' q q q q cYLAYPDS . . . ..f V-e V V�.e U 0�:� F- r- V S = _ x - � � G � .,� �w �. .m .m, m�. :m �. '� `�' ���ll k151 H5l H51 1151 H51 = ? " w rn I HLUUING =' y I :� m � � `" � �, �+ m U � m w m m m m � a I ALUDII�G � � m M m „ � i h - �' SWWGS H4CtIA1RS� ; � F2. F2l ''�'�- H51 H51 NSI 1151 H51 ,�,� a� ,� � s 0 BABY � I � .� �� ��� H7 H� H7 HI29 H129 = 3'T = .� � STROLLCRS ; � E w DR:V LS IiAILU\i'AItL .. N� 11 �. :SI � 's •51 � •til •} `�� m � 5.. . N .rv .ri� rv N. rv .. 0.' : y� � S 9 � a m m m m w `m 'm � I � TOSS uH.ar. ncc. z z��� o � � .. . J rn � � rv .;� � m�..� ,�, o. a o. ��m a = u. � w, �,�°°,, " u. �' .c�. �. 'ii u. �� i.. �. � w �. w ��� n, i iiiz[ HI>_G t�121, H3 H3 _ 5� 5 m � N ._ .' �� w �m�.::�:. '.m.. m. �m m m. ...�.?I. � r"i, _.. , .. . _. �. _I _._ ._... . �- .�� . . . . . . ���.z �H25 �H25 H25 HIS h115 x �. . S . - ' CARSL•A75 _� ,' I � PUILN1�fUItG LA.bfYS < v'^i : ���. ��� . ' u WALL i � CRIA." � '�� �' W :' : . � � 3 T � .4. =SSM.4LL.4IiT ' , : 2 .' � T^ fRA�1CS � I � � q � � � � � � � � V1 � , ! � y`� H8 H3 H41 H91 h141 � � ' rv � � m 9 m m m q '� a H o L� �°' �. °1 n N n �� N N' m a w w��� w I w. �/ �+. �;. �: .� w: w�� � w , . u. O .. i;. �. �� i,. . H I H l H 1 H; i H31 '�� -� ' N � U ' � I F��� � � � � .CA�ULCS FL011AL x� �� m m m�, �:�, O � HOME � � � � e � � � C��I.75 1 '. � �n ^ � GIP'IS N ' �-, �... � � � . � � ;:; I ; O J ` . � q ,� 4112G H12fi H12G HI?6 ti124 = � P� ; e � � , � I . .. . -, ' , ' ' - N o u � . "'i u •..:. O >r• � _ : H4 H4 H4 H4 H4 U I Q z ........� � ......1 ....:... '_..,...... . �� ' > r ' F59 . .. F8 .. . . � � � . G � w ��.� I u, � u. ��. ' u. . , LL � • t'' �.. �o o . r.00�. : N �j w N } u. � �. i.. J _ ' u. � 2 SLASONAL � � � r m Q �:} ;. ;s 0� s' W G6NLIL�IHOUSGWAILLS K:1'OWCL�' 3 ' E � ¢ y � s � si � ° � � � si a � sl 3�+ =. '3 y : �: �..5� .. 5� : U H4 H4 H4 H4 H28 ' � - ` �„ ....:.: .........� ��� .....i:i: � _.t ...... �. t ,f� 3 ' -"°�' ,� � :,:� s . : ;:r o : _c o : c } �.' t} d' � i p = i ���. . ��. F59 . F8 � � .�� pti '�'�-y.t a e 'Y U' f�:a .I = ' ' .. C i :�O O.�e ��.o �p O i o O i :O o.z H4 H4 H7N H7N H7S Y _ v : ti n � : : : `> . .. � '' �... . .. . ... '..: . �:. .. � . � � OUR�ILI N�1A7S/ ICLCIIHS , , .y��.:r/1' �.�.�.�y�.Vt . �... �y. . . � �-.� � ..� � �N 31 •y��m 9.�.�y: G wa � . r, � �J-1 � ^., ��NS �G .. . .. .. y _ - � �z� ' ...... ,.....:__ .....: ..:,:. .:. . � ' . : . SGILVGl4ARC fLA1WARL2 3 � ' F59 F8 ' � . . O: c H4 H4 H4 H4 H12G rn 3' Y v 5j � ' ` Z � ` � C�ATS " u.1�� : .z � HS HS H12G If12G H12G = �� "' _ r _ _ , ; ' , ` _ ' /5 UINNLR HOX UINNLR '� �z I .....�... A ... ...:" ........: ..:...... . �um� . .. M I N O '^ � � '"�:1--Fi--7�-�� ' �59 .. .... FR : nf7 �. s� I I �si �� �}: ��� ���si I ��� U:\KhW:\I21 G:\L'G[75 � z 'L W � � '� � _. � . ._ . ., .rn ��- N�.�_ •N ��, �� �i �� , ,. v�i � ' � �� '�` � �rn H6 H6 112R H'_S HR rn 3 t � . . k. . ' . Lr. �. W . I W -. ( 4. � k. .: W � . 4. �: 4. . � . � LL. � ti . I 4. � ti . J � � W ' -; 1 ` : �. � �: I .. ....:.. ..........�� ... ...:.: .:.....:. : } . . . ' I .UOKW.4R1. CUILLR C, � Y= 1133 H73 H33 H3] H12C = o � Q ��py � - �i ��" , �r F59 �, F8 - I z a ( � Y � � � p/ I .. . ... ... ..... � I '. � ' I W CI� I a � LUGGAGG � ''' � � ' _ ' � . _� r � � .. W . �' � �. Q� ,� H911 }I')0 H90 FI90 k190 rv � x � ` �, w w W ta u. u. �. c;, w c�. ii I H �;. ' s� x � x m ..,.:.i, ...,,.. .........:. .. :........ � I � Ny Vi : V] z [�] � F190 H90 k190 I{90 H90 � �. �W _ F59 . F8 _ :.�I . „W`„i , �..PI i ', r .: .'_7 ._. .. _ ^ aa � i : � . _ .. � LUGGAGfi . _ _ . . . ' _ _ � _ � � � . �. o e� e. ��. � � U O�j; �/��; cai� Q pa I �uccnce _ I^� � a i ��I : ' i� : �' ^: ' I : �" I k190 H90 }:'�p H90 H90 n Y oc - � e, SH32 SH72 SH72 SH32 SH32� SH32 SH32 • . . . i � . . ' .. ... � t � . , _ _ ' a i x � ' � Ix SH32 S}132 SH32 SH32 SH32� SH32_ SIi3� I I I �� �� ' : � H90 H90 H90 H90 H90 � N I � w W : u. w � �i. ti. i;. �i. u. w � �i. u. . �i. �UGG-4G- _- - - - - '„ " x x x ��., SH72 SH32 SH32 51132 SH72 SH32_ _FH32 � �� � I s� I .. I �� � . S1 �� � t� I �� °� ' �� SHI2 SH32 SH32 SH32 SH72 SH32 SH32 . ' I I '. I i � I �� SH72 SHi2 SH3_' SH32 SH3'_ SH12 = � ' N SH32 SH32 SH32 SH72 SN32 SH72 . � v � a i WOMEN'S SHOES � '� �� MEN'S SHOES � � _� ' SH32 SH32 SH72 SH32 SH72� SH32 SH3� . o m SH32 Sfil' SH12 SH32 SH3_ SH32 � ' � � SH32 SH32iSH32 SH32 SH32 SH32 SH32 .. . - . ? ' P SH32 SH32 SHt? 51132 SHi2 SH72 _ ,.a. _ I 700 unit ca aci � h � 3,291 unit capacity �� , ,a.o. I _ . , _. �., SH32 SH32 51{72 SH32 SH72 51132 SH32 : : ; � . _ . °` SHi7 SHi2 SH1' SHI� SNI� H72 '-� ' y.. ...= SH32 SH32 SN72 3rii'< -Sri32� SN)2� Si13� .,..., : I 51 ' �..... �SI. '�: . .. .+1 Sk132 iH32 SH12 SH32pSHJ2 SH7? _ �Si.' : � ,.... ; .... : . ; �'. 5 � P� i . � - � _ I� i�� L------- � � , ' ' . W � W �: 4. :- W � LL' � U+ - W �� 4. - W . LL. � ' - SH32 SH32 SH32 SH32 SH32� SH32 SH3? I '� SH32 SH32 SH32 SH32 SH32 SH32 SH3"? ' � ' W . i - ' = I i . FQ-� �., SH32 SH3? SH32 SH3?� SH32� SH32 SH32 � I �, � p� Q 1���2 SH3�2 SH32 SH72 SH32 ��� Q ' SH7 � �;. ; W w - , µ, �.. � r i;, , p.; . i;. � . �. ' � ; . c;. W '.w � � .������.�� E�� I a{ w � `"� HOSIGRY SOCKS -�� ""'� � � . � . 4 U4 D4 �n �� �'�. F' 3 Q E-' � D4 D4 U na � � VO ❑ W I 's ' o� ' o. u4 �4 ll4 n4 I u4-� �4 `� a (� W i O � , v� � � . • Q - �- �� � v�i . [XbRC1SE WSMGTICS � I . z . ❑. ...... Py+ [i � . I ti ; . IciM�.� I���.. � �i. u. 'u. •w '� •µ� � � 'u, �' � .: � .:� ' 'rn.- U3I �, D31 �. � U31 � D31_ U31 � .-03l - • -. .. .. .. : - _ !� � � U4 D4�� � U4 . U4 D31 _D3l �� Q ' . �- � . �" ��..~. 13LAU'1'Y ACC (.OSMG7lC5 `� . � I s� s S ' ti� . si .� � �s� �. ❑ y I : �� � ,��"� HAIRT(X7L5 HAIRCARC SKtNCARL> - - � rv q mrn 04 � DH � ll9 D3 DA_ D3 0� .� ��� �. �: � C�.,� m�� � ll8 DR .� Uft US . US I� .. . . ;� ' BATH8:I30DT" - I �y{� ' �■y�' � �y..p..1� � ^�.p(..�' .��• ..�y... 11;.. ���. IL,•., �.... .���- I,i���:� .��' ..IL,��. ' � �� � HANDBAG . ' w N )79 U1 DI � DI DI �� DI � m. 4 4� C4� .���f4 LLF4 P4 , 4 ��� , � ^ �.��UI�UI Ul � ' Dl Ul UI � x . ' . � � � A�C�SSORIESlld.��s � Q� I w,� DI DI llt UI � UI UI DI �.. �� � fff��� %a � � -: I 3� 29 U29 UI UI DI DI Ul � Q. � j . ,,,(((�����, Ov ,.a WALLL75 HANDU4GS u � `�( CH31�. (:H3I . 'H I� ('H31� .H31 ' .. I ❑ 4=� CH31� Ctl3l CH31 ...CH31 'H31 ' _ :��.�� � .. . __.. .._...._. .... CG3�U�1LJ.:..�..�'i . . Da. . _ u ^" i ; . .. ... ..... . . �I � z� oz� oz� oz� uz� uz� nz� � : � -� � IQ. V O )�) ll29 U27 U27 U27 �27 U?7 � - �� �m 60XLUJLWLLItY COS'IU�1GL•WLLRY - . . ,H. 71. �� ' WATCHI:S � �� • � ; �, ' t�� _ i� mi nz� uze Dz� nz�] � aocnttrs . I^� �� ��� U�� U�� U4 . U� � UQ �U oa ' � �- RU.4NK.4S COLUWHAlH6R��� �r"�^r' �� � . . �.<*wna ;.. �.,, � m , � .: , �. : j ' �iave ' �iavk ' �w�K ' �iave ' �w9k ' yiayx . Q '� HA75 COLD WF.ATHLR � rv U( . DC. OG . US DN D8 '�.� 7 6 $ 4 3 Z . � �^ �o DG D6 DG U3 lll0 UIO o��V , _ �, ¢' � HA'CS tL4IR dL•L'IS -� I . CHL•CKOU'P/RGI'UKN sl ncc. �,��,� ��s ��..��� �� ' � SC.4RVL'S VESTIBiJLE t.,, q Za � CI141 -�� � n�F56` C113. CI17 CII3 . . Y� D24 �:: U24 D?4 ';. D24 U24;: n24 � D24 ... �� � . ...... CH45 CI145 I ''; 8'-3" 8�_3�� : ,. \. ' � C� C� � ; �] _ ❑ � a , ,.. _._ . �, ��T���� E������ � � �� � � �,�, ��� � : � � � a, � �� '� � � _ � � �, � � ' • � �119 � ...:..VIJ 1L` 1<rVL'.HR ...:.:........ ......... ' - � P3 � - FR � � . .. .. I :.::.:.:. ..........::.. ............:, ' s _ . F8 - . .. . F8 . �. . . . � 5 . _ :..:... � �.CN ..i... , .FB�.. .�.�...� ..::. ' �5� TAILORED I � Fy?� ''- E : i ' I L ' ...�.:. �... ....� � F4 F4 4 ' S I���M17�`A17y y j.�132x � 5 J < f S U , POWGR ROON ,� EXISTING DOOR TO EXTRA SPACL (WEL�ED SHUI') z z z _ � _ � x mN = � rirv� Nc ., � O a' O � y_�v ' _ ' N � y H7� NiS. 55 SS �n55 �SFN � zf5y � 3 �n x � L �11 I. � n - S . x �l J �j' -' ' Ra OSSC SSa. . SSy ...silr p5c �SIS;� ,ii�'" � .. . . . �' J � ii 55 55� 5I` 55 NSS� i'S5�5 . I�119 �.Vi1') �i273 M23 ,�117 �II1 :N32 5 1�G\VI:LRY 5-1N. NuekweAK rURNISHINGS ���i, ^j V � �13 '� . :N7 � � �13 : � M7 - -: M3 � � �13 � �� Nl �� � �.17 M3 �13 � ' yi,.ve i� � �. i� �. �o � � °;�,a" ����� ���� CASH II COUNT ,RV STORAGE ea �a i,��" F56 s� CIi41 ' It7 R7 It7 � R7 li7 � EXISTING 8" F[RL RISER 0 SPRINKLER F.00M � r (N.I.C.) Y Jt-t��� (i���� � . S I �4# .�i�l.Fl��� s�. �cx-ru�� ��,�N, M�-r��i,�L s��c►��c�,tio�s �o�r�5 � 5+���r IND�X. � S2. FR,41"(� �L�1��4TfONS � D�T�411o5, LOZf�i� 1��T,�,I1�S. 1„r���fi�1�4L Sfi��C«fC��'f0�1� �. LOZI�fi� S�-IELVINC� ,4) T1'PIG,4L S+��LI�INC� i�OS7: �-� �5.0 fGSI 1"iIN. C�STM ��0�) 1�=2qx10 i=�I) }3) T�'PIC�4L SI-F�LVINC� S�AM: �-= �O.O fGSf 1"11N. C,4Si�i ��0�) 1�-2qxi� PSI� G) 71'i=ICAL SN��.�: F�-= ��.0 fGSI 1"(fN. C�S7M ,��Di� l� =2q x 10 �'SI) p� T�'�IC�4L S+�E�F 8,4SE: �-= �5.0 fGSI MfN. CASTM A3��) C�=2qx10 PSf) 11 C��. C4-4,4NN�L E� T�'PIC�4L SI-4�L� Afi�M Bfi��4CK�T: %�-= i0.0 KSI Mfi�l. ���-S I ���� ��� �/•"it.� �� T1'i�IC�4L S�ELF B,4SE Bi�4GiGET: �-= �O.O �GSI MIN. C�) l.0 f 1�ES�',4N 8�45� i�LA7�: 12 C�,� O O �'= 30,000 fi�S f XISTIN S A � . � C� L B ,4� �" tNIGfG CONCi�T� F�= 2500 PSI MIN. ALLOUJABLE SOIL i3E�4RINC� 1000 i�� �. CONNECTION M�4tEi�lAL ,4) 3i8 �� ��-IILTI 1�UJ IK NUS EZ �NGNOi� SA� J�03 C�i�,4D� 10821 E�'J' i�#- 3�2�i. S��GI�L INSi�EGTION: S P E C I, d,� I N S i�� C i I O N I S �� G 2 U I R E p � O i� ,� L i�ACK F�LOOi� ,4NCI-�OizS fi��i� '"� �, � ,., 3 "� L� »y '^"'.+�en.aw D�SIC�N L0,4DS: � . _ � �i�,41'"?� �-UJi"1: I�l� = 3.0 PSF/S+�EL� F.i� � �.� 1 VI /V���� FizAM� B-i�12: D� = 3.0 �'S�/SN�LF i�1� � �.O ���/���i�� �i��M�S �1: 1�L = �.O i�SF/SN�LF i�AT�D LOADS: LL = 180 LE3S/S�-IE�� � � � � i �INTE�NATfON� �3UILD(NC� COI�� SCE - � -10 � �` S�fSMIG. Ss Si SD5 SDI S� I SM I C IMi�Ofi�2T,4NG� ��CTO� R(SfG G,4T�C�Oi�Y S� I Sl"i f C S I T� CL,4SS S�fSMIC 1��SIC�N CAT�C�OR�t' i�ESPONS� MOD I� I C�T f Oi�l �,4CTOi� C i�) S�fSMIC r2�SPONs� CO��IGI�NT CCS) ����;,��➢��,�� �a�( � � ����� ��f��s;4'� , �. � �- .�. �., _ �;��C;�' e�"� �' e� �°�° � � �-, = �;•;; .� ��?� � � �����! �l[ ''��1�;1�dl�� 4f{� �G`���?�€�� = 1.��2 = 0.�3�1 = O.q(o 1 = 0.�3i _ I�� = D _ t.�. = 0.24 RECEIVED CITV OF TIJKWILA JUL 20 2016 lP�RNtIT' CENTER a ,� Z0� p � H�<<\e��� .'�°f.��sy'y'•• ,' � Gt. � ., : ;ti - �: +� x . + 'O :y � W � 14723 �Do� .��,� �a�,o�\�4, y N �. r �12�'Z+�IC. � J�E P. HILL, P.E., I��, CONSULTING STRUCTURAL ENGINEERING 1801 N. Hampton Rd. Suite 440, DeSoto, Texas 75115 (972) 283-5111 FAX (972) 283-5113 ph, P.E. Job No. 16-279 .. ,,.,., ,.._.�..u_ ...M._,�w,rn..,� _ ....,m. . _ ,, . .: ._ . ... .. .... .. .... _.. .,.. . _ - ���',;:��i�wP'�"X:��`�i,<��� ,:; � ����;� �� , s� �. STOR� NO: �; �- -� :�.,: � , �,� , �, x�''� , � �� �;� `��� �„ ��: � �� � �� E''%w. "`w� �r �' ��" �; '� ,���*RM�:�.��, � .. ���:;�s����w �� �.�, „:F...,� • ! ' ��r�; ,�� .. .. : ���w�� �:� :, ,�� �� � .a� �; � •. ���,�, ��d �w ��a �� ���.� .• a �r��3&t'a�:;l�'� • +" av�� ��`� :a• � � � �vs • � ;���,$�'�°r.�; � + - � ,�.� q.��. .. w �� x„ ��� ���: g��, �� ^1' � � d�. x�, "�a�"t'"4�"� R"••3'�"9�u�� REVISION DATE Rcviscd b rcducin and Y S 1 rcarranging back of housc �/24/2015 and dccrcased tile aisle width t0 6�-�u. QRcviscd to single slidcr 2 cntrance, added a register, l0/23/2015 decrcased storage room & adjusted front tile. Rclocatcd baby kiosk to bc on wall. 3�• Addcd perimetcr aislcs. • Rclocated Uaby kiosk to 1/04/2016 comer. :^+: �'�°x*, �l at�� �� M `� � ,.. v ��;��� '�dk'� .i;f�`�.:; '�k.m*.+'n+�v�;;i�j,�.�' �" �� m . S;h�,a`��. r:" ." ^&.;�.. ,:�til�f^*�`t m>�^,:a,e,^.�TMa^: a,',.: ,'M,,,�?a;.;;:{ ISSUED DATE PRELIM. DISTRIBiJTION 9/17/2015 REVISED PRELIM. DIST. 9/23/2015 REV.2 TO LANDLORD 10/26/2015 PURCH. 5/ 19/2016 DRAWING TITLE: FIX'T�JItE PLAN DRAWN BY . TLA CHECK. BY : DDP SCALF ASNOTED DATE 8/10/2015 m �j W II��Si=�4N SN�LYINC� DEtAILs: -�2�� ��N, UJ IU�S}�AN U�'RIT� T1'PIC,4L t3�AM TO NO}zI20NT,4L � UJ IDESi�AN BEAM DETAf L (��4ME �1� ���� COLUMN CONNECTION D1�4C�ONAL �.�r��rN���t� 2�0.�0# �EvE� 3 a� Sfi�,4C� MATERI,4L _ ib2�✓ a- -N T1'P. B07N ENDS `" \ � '�s �ULL LENC�7N 12 C�A. NOOK SEE � 1� CxA. POSi' M,47�R1,41. g�AM ,q NOOK DETAIL 2�40.�0� �EV� SP�CI�IC,4TIONS: H07 ROL.LED g�� p��„ 3�� --- — /�Sth1 A�✓-�O Gc%' �45 OR EG2U1�/,4LENT %a 7NICKNESS: .0�20 MINIMUM � - — — � SPECIFIICAtIONS: — — — ,� m � � 3/�" x 1 il/32" x 20 Cx�4. UJA�.L ��NC�tN"(+/-) A � p STEEL tUBINC�. �, �, � 24�0.�0� t v�1- � p� ❑ � � JOfNT UJ�LDS � UJID�SP,4N \ +- � � � - � SEAM Q � � � � \N - O � \.� -- � ❑ � O m 1/8 5/STYP. � � ❑ � UPRI1'E � MIN. �, , o s�� ntl... � ��N�t� _ _ i�E: ANCN4R f� D�tAIL 2 � �N `� �OR AtTACNMENt 70 � � � � \ ��� �XIStfNCx CONCREiE SLAB _ _ � ��S ��BtYp• NOOK DET,41L SEC710N A-A = M�N. 12 Cx,4. N07 RO��.�D StEEL 16 C�x,4. NOt ROLLED Si'EEL � � �� � �� 51DE O� POSt �RONt O� POSt �-���t� +-ISLA CxRAD� 50 PEi� ASTM ASTM A607 C�R 4�, CLASS 2, �-O � � 3-O � SPECIFIG,4tION A"115 �0,000 OR SAE J 13q2 O�FSX PS1 MINIMUM 1'IE�D StRENC�tN 45,000 PSI MINIMUM YIELD � 22"P X 120"N WALL MDUIN7 �,_O,� lll �� w tn - � N � � 111 LONCxITU�IN�lL c) _ Q r�i n�.i vi�iii n� t�rrir�ai I.e�rnilt �nc� �t�dMR ���_t21��� 4�0.5�# 4(o.5�f# �e 4�o.5i# 4�0.57# 4�e 4�o.5�f# �4�0.�✓-7# 4(0��5�# 4��0.57# 4�o.r✓- �� 4.e._ 4�0.57# �4�o.��f# - �xC13) - �XC12) —► �xCll) - �xC10) - FxCq) --_ � x C S) —�- � x C �f ) - �xC�o) ---•- F x l5 ) - FxC4) —�-- � x � 3 ) - �xC2) - FxCI) � � �'-O" � t1'P. FRONt PRO�ILE OF �iv4ME "B-i212" -r�r�. s+���� �i : M,4t��?1,4L Pi�OPERtIEB: �YCBRACKE�') = �0,000 P51 MIN. �YISN���) _ �45,000 PSI MIN. t n � � c �� UJA�L B�' Oi'N�f UJALL MOUN� t�'P SE� DETA 5A/S2 SNEL� WIptN 20 CxA. STEEL i SNEL�� —� ^c� o 11 C�,4. StEEL (BRAGKE7) Ti�. Ui�i�IC�zNi i':�: 123i" P�o���ti�s: - �,�.(S7EE1�) = 55,000 PSI � fi,i�E,4 = 0.�5� IN 2 � �ax= O.(o30 IN3 S �- = 0250 IN 3 I x= o�n IN � 0 I I IY= 023i IN 0 � � Rx = 1.03q IN A A � � �Y = 0.560 IN � � � � � � � � �4StM ,41044 � I I NR 5tEE1� SECtION ,4-A 13" a m N � 22"B X 90"H UJALL MOUINt ��_O�� W �� w � - Z N � N I— � LONCxITUD INAL � � PL�4N VI�W O� 1'YPIG,�1L �A1'OUT FOiz �R�4ME "B-U1M" _� O O =� O �4 _ r- O .. O v � � �i- cf� - FxCB) — �X(�) --= � x C � ) - �xCS) - �XC4) - �xC3� ---= F x l2 � - FxCU , I � �,_�„ � tYP. FRONt i�RO�ILE O� �RAME "B-I.UM" UJAL�. BY OTNEf WALL MOUN� T1'P SEE DETA 5,4/S2 tl'P. ENp PROFI�E O� �R�4ME "B-IUM�� I(�1S—feqLLAl�I��l I�ISTRUCTIONS WIREGRID BACK ASSEMBLIES (ONE PIECE GRID, UP TO U96) Step 1: Set up sheiving sections following display shelving installation instr�actions 01-13 using either BR OR BRHD_ bottom rails. See retainer types on page 2. TOP RAIL (R_T) o 0 °aa UPPER WIRE o 0 GRID S o RETAINER 0 � (RUS_) �II�-�, v o EXTENSION WIRE GRID RETAINER RAIL(RES_) STANDARDC BOTT'OM RAI (BR ) HEAVY DUTY BOTTOM RAI (BRHD_) 6336 PERSHING DRIVE O�v��� OMAHA, NEBRASKA 68110 p 2015 LOZIER CORPORATION 228-9882 � WALL ATTACHMENT DETAILS Q N � i (� S cz(1 lL X IUALL MOUNT BRACKET f DC219U �• i i 0 4 u� �� � a , �p 2x4J BLOCKINCs t7P. 2 x 4 BLOCKINCs � WALL MOUNT � 71'P. �/a"� HILTI KB-tX At 16" O.C. MAX l2 BOLTS MIN.) 2J�i" � 11N. Ei�EG71YE EMB�D. � DETAII. �1 COfJGfiEiE WALL II Y' � Ni—F+ � $�"x�" LACx SCREUJ 2x-0� BLOCKING THRdUCsH UPRITE INTO BLOCK IMIN. 1�i2" PENEtRATION INtO (2) �i4��d�X4" TITEN LUOOU f3LOCKINGs), IUITI-lOU7 LUALL MOUNt MA50NRl' SCR�U1 BRACIGE7 AT 24" O.C. MAX l2) "lOx1�i2" U100D SGREUI V4" MIN. EMBEDMENt tl-IROUCaI-I U1ALL MOUNT BRACIGET 1DC2191) INTO BLOCK IMIN. 1��s" PENE7R,4tION INtO U100D BLOCKINCx), IUITH IUALL MOUNT BRACIGET AtTACN AS NEAR A5 DEYAIL � � POS5IBL� t0 UPRITE MASONRI' �IAI.L RJi.LY G�JIiTEp CMU WALL ,47t�4CNM�NT D�TAIL ,4T FRAME BU1M � BR12 StUDS A,T 16" O.C. 2 x UIOOD S7UD8 A7 2�" O:G. MAX. BY OTNER� (E) DBL. 81LL PLATE MAX. BY 07HERS At SIM. P�AGE 2 x 4 BLOGKING 2 x 4 BLOCKING SCR�WS 1NT0 CENtER OF 2 x 6'8. � BY OtNERS (2) +'8 S�LF DRILL 11) $�"x4" LACx SCREIU SGREIUS A'f EAGN A7 EAG!-i StUD 1"tEtAL STUD 17UJ0 STUDS MIN.) DET�►IL C DETAIL D WOOD SillD WALL METAL STUD WALL INSiALLATION INSTRUCTIONS WIREGRID BACK ASSEMBLIES Step 2: A) Install the lower horizantal wire grid retainer (RES_) on the bottomrail. B) Install the wire grid back on top of the lower horizontal wire grid re:ainer, The wire grid back should locate in the channel of the lower horizontal wire grid retainer. NOTE: See Figure 3 for wire grid back orientation. C) On each side of the wire grid back, slide the vertical wire grid retainers (RES_) down between the uprite and the wire grid back. The wire y; id back should locate in the channel of the vertical wire grid retainer. If the wire grid back is taller than a nom 48, the vertical wire grid retainer will be a two piece retainer (RES_ and an RUS_). MOTE: If using triple tra:.k wire grid retainers (RET_) with a centered hardboard back, slide the hardboard back down the center channel of the retainers prior to installing the upper vertical wire grid retainers (RUT_). D) Install the upper horizontal wire grid retainer (RES_) on top of the r�ire grid back. The wire grid back should locate in the channel of the upper horizontal wire grid retainer. E) For systems with two backs vertically (taller than U96) go to page 3, Systems U96 and shorter, go to step F). F) Install the top rail (R_T). RETAINER TYPES: GRID WG) RETAINER RES_ '--' 'J BOTfOM RAIL � — — iEMBLY SINGLE TRACK DOUBLE TRACK 84691 REV A3 6336 PERSHING DRIVE ECO# OMPCOA-368 07/31/15 ����� OMAHA, NEBRASKA E8110 PAGE 1 OF 6 pz015LOZIERCORPORATION 22$-9882 RET"AINER R�— � EXTENSION GRID RETAII (RES_) STAN DARD [ BOTTOM RA: �BR_) OR HEAVY DUTI TRIPLE TRACK BOTTOM RA (BRHD_) � 84691 REV A4 ECO# OMPCOA-368 07/31/15 0���� PAGE 2 OF 6 p2015LOZIERCORPORATION � MA7ER1,4L: 12 Cx,4. ASTM A526 COMMERCIAL 12 C��4. +-107 i@OLLED GOMMERCII�L G2UA�17Y Gc,4LY�,NIZED SHEEi OR QUA�171' SNEET PICKLED ,4ND OILED ���� i1'P ��� � ��n aEF i. US� TU10 l2) 3/S" D1,4. �diLtl KLUIK NUS-EZ aNCNORs IUItN 2 1/2" NOMINAL EMBEDM�Ni PER ANCNOi� f'LAtE IGC EYALU,4tION REPORT �SR-302�1. SPECIAL INSPEC710N IS REQUIRED. 3. USE 5/1�" x 2 1/2" C,ARRI,4CiE BOLt t0 ,4t7ACN 70 �R4ME E B,48� �'L�4t� DEt�41L �Ofi� �iz,4M� �1 SCALE: N.T.S. Y Ii�JST�eLLATl01�! INSTI�UCTIOfVS � WIREGRID BACK ASSEMBLIES (MULTI-PIECE GRID, TALLER iHAN U96) Step 3: A) Install the splicer rail (R_S). B) Install the lower horizontal wire grid retainer (RES_) on the splicer rail. C) Install the wire grid back on top of the lower horizontal wire grid retainer. The wire grid back should locate in the channel of the lower horizontal wire grid retainer. NOTE: See Figure 3 for wire grid back orientation. D) On each side of the wire grid back, slide the vertical wire grid retainers (RES_) down between the uprite and the v�iire grid back. The wire grid back should locate in the channel of the vertical wire grid retainer. !f the wire grid back is taller than a nom 48, the vertical wire grid retainer will be a two piece retainer (RES_ and an RUS_). E) Install the upper horizontal wire grid ;etainer on top of the wire grid back. The wire grid back should locate in the channel of the upper horizontal wire grid retainer. F) Install the top rail (R_T). TOP RAIL � � (R_T) SPLICER RAI (R_S) UPPER WIRE GRID RETAINER (Rus_) RETAINER RED_ � __URE 2 WIRE GRID ASSEMBLY WITH SPLICER 6336 PERSHING DRIVE 84691 REV A5 OMAHA, NEBRASKA 68110 ECO# OMPCOA-368 07/3 ' 228-9882 PAGE 3 OF 6 3.�5" MIN. EDG-E-- ni�t. �5�-3a2� - a �,�= a � GR4CK IN =� CONCREiE �M�E E>:IStINCx SL�1� —� CRACK IN CONCi�t� v � a � a3i8" DIA. 1-Il�tl I-�4U5-�Z �4NCNOi� - 3/�"j DIA. Nll.tl HUS-EZ ANCNOI�s lU ITH 2 1/2" MIN. EMBEDMENT t0 BE SCREWED DOWN _ � tIC�Nt_ _ _ — ° _ � a a . a � a . . _ o � a a '� d . � a .. ° a a a .d �� _ — — � � � "— — 3/S" � NILTI NUS-�Z ANCNORS I INSTALL�4tlON TORQU� tnrer 40 �t. L #i��Ei�NGE ESR-302� � � � � ��� ��M� � � � RECEtVED Cli'Y 4�F TUKWtLA JUL 20 2016 PIERnAI'T CENi'ER s �O� P • N�l����� _' .F '�qS ,�1 : � y��'�• ; h �� i►e - a: • . v� z � * �u • • � pp'� q� 1_4723 p� t,�� . �w'r^ GZiYf'iZ�:' � 2 � J�� �■ �B�`y ���■y '�mI■ CONSULTING STRUCTURAL ENGINEERING 1801 N. Hampton Rd, Suite 440, DeSoto, Texas 75115 19721 283-5111 FAX (972) 283-5113 Jph, P.E. Job No. 16-279 STORE NO: � � �. � �• �»� �� � � � �� �m� �� �� ���:� � � 4r � �i' ��. �� � �� � ��� �rv �..�s��,�..�w� .,.:,,.:, ,��., _,�.�,iu,_:: µ, r�������: $}'k� � ,�,������: . � - � �'�o�:k^''iu^l� • • � • ��rv;���+s:�;��' . � �.���,. �' • �� ,� �� -,. ,;�w:�,���:�c,ti� .� ;�,�.�,. :°� � :�� ����s°;�m, � ' .. ;,�� x��� � � �_����; � — ,� � �,����;���� � . + i . � ,�,^�� �r��. � � ���,�;:��.;. .. ��# � �� �� ��� x � '"�; ��� �`� � �� � ���� ��.� � REVISION DATE 1QRevised by reducing and rearranging back of house 9/24l2015 and decreased tile aisle width to 6'-0". �Revised to single slider entrance, added a register, 10l23/2015 decreased storage room 8� adjusted front tile. Relocated baby kiosk to be on wall. �• Added perimeter aisles. 3 • Relocated baby kiosk 1/04/2016 to comer. ISSUED DATE PRELIM. DISTRIBUTION 9/17/2015 REVISED PRELIM. DIST. 9/23/2015 REV.2 TO LANDLORU 10/26/2015 PURCH. 5/ 19/2016 DRAWING TITLE: FIXTUI2E DE'I'AILS DRAWN BY . TLA CIIFCK. [3Y . DDP SCALE ASNOTED DATE 8/10/2015 O � 0 � N O � N O N N D _ __ . 0 � N E _. 0 0 O � � N N J O , � � N O � N O � N � N � N 00 M �' ' ____�t}I I;�� - � (') �t:. ..�� O: �i'' j� �'� . ��' �' 55'-0" � � � 26 :1_1 Jnu `________ ��I ; c. i c..i JAN. EMPLOYEELOUNGE ci er ei ei ei ei� , � �.. E13 ... LI3 � �El� EI GI, EI CI C•1���� . ��T , � � G5 .. �,.. �6: .. 165'-0" 55'-0" 55'-0" CONT;AINER � _ I �R19:8� R19.6`_ FIXTURE STORAGE RECEIVING POWER ROOM CV p �� �� � ..... ... . . . . . � N .. RI9.& i19 8' � . .. _.... . .. . _ . .. .. . . . .. . -- _ ..-_._ _- _-__ � R42 !( R42 j� R42 i l R42 I 1 R42) I R42 l� R421 ( R42 �- -- °� �� . . . 19.8� R19.8� t19.8� LAYAWAY m 630 unit capacity e sn� PR � � (� w w _R42 ) �R42 ) ! R42 J ! R42 1 l R42 ) ! R42 ) ( R41 l R42 ) � a' ' O i IQI � '6 8 6" ,.. ._ . '6 4 v a I_. � `` W W a i w w WOMEN^S FITTING ^ !' , r�NS FITTING �� I I=I � . , wl .....E LEARN/LP �. .,". : - - �..� ` � LS C8 E8 E8 MGR. ...,. . `$ ' 2 . O • . O O F'63 $ �� \A/ - - - - - -. . .. .. .. � ..... 1. �%... �6 3 fi 4 ... �6. 5 _. �fi. � :6..._ 3. 6 _. 2 � \�.�. RI9.8� RI9.81 RI98 E I I / �1 . ....... � ... .., ` . , �. . ' � gJ � - w �= B7J ! B3} � (B33) 1833 7,B33 ... BI4 � 1 B43 i B43 i f B43 r! 843 )( B43 1 B43 B43 l, Y.� .,�_ YI :: ). I. L 1.._� 1 YI I i Yl 1�. i YI; YI YI YI. ___ __- - '-'-"- I�I . .. . _ . . .:.: .. . :.: i..;-..,. _.-:: , z..... . ..:. . H75 �H7 (H7 ..�H501 �_HSi i STORAOE - LAYE7'['C GE BER SIIOES SOCRS ACC. IRLS A�HSSORIES �� . :BOYS'ACCGSSORIGS � STOItAGE5/ S� 5 HAMPGRS H751 H7 � I.^,�I - �;: � � OIF'CS � •2 2 � U __ - . - . . . . :: (BII)� FI3 H3 H3 PETBEDS „ I�I� 6r B37 B37 �B37� 1B37 (B37 iB37'. � _ I P . i�I Im .. ___ _. N ,,, H126i �.Hi26� H_126� �.HI26� H12fi i�,�S $� �^ B37_ B37 f B37 ! B37 (.B37 ( 637 r , � 9-� � d � Im; I�I ? `� � � � � � N �S H2R ; � H28 ) H28 i �. H28 i H28 x� �: ; , . r�"+ � ¢ I � N W I�I BA7H pp771 PAI � . � 'W ai '°I ; � r�� _ _ �PETPEGGAIiLES � DIAPE2B G _ _ � � � _ _ _ .. � •� _ ___ _ �_ i _ :.. ; ' ¢I, �l¢1 . � N O � � 7� � S _ . I , �e. cuxr. sHwa. cc. ' ' � �r' = D35 D35 ( U351 l B35 1 1 p35 i ( 0J7_. � °` ' � �` ' . °` :°` ��` . „°`� .. „°`� �.� .� ..y . m' � Y - - a " H28 1 ( H281 ( }I26 ` ( H28 1 AH28 I % � I I �t ____ _._ . .__. .. � , , � , rn rn .. .. . . .. r . ^. . ,- . _- ' _' " � (n W ' 4. ; li � �fi W . � � 4. � W ..� W �.: 4. ��.�. 4. IR11 IOJI :S �I; . l� Im, U35 B35 / BSS ) ( D35J 1. D15 ) l �75 ', �� .. I .. O . ... '�" �- � � '� � � � � � � fll2_1 ( H12 H12G� iH12Gi HI26 _ ___ -_ _.___ __ . - . g jII CG . m . -,.N �I . F'I"I N _ . . BATFIENS. DAT[IACC. . I�+I _.. BATH tIEALTH ELEC. & � m � � .� ^ I +P�i � � .: � � � .,:� � I,Y,� I"i Y ,,, - � �,� _ � ,� - �� d IIJF. SAFE7Y . .. { . . . ,,,� p .:� �m ,m . �� '-- Q V FEHD.BIBS TODD. FEHDIN a ' , . .' I �� O N ,� � .� _ F y p H R GS UG SCTS o.:� nI� �"= __ __.. .__._. ._.._. ._- ___.. .._ t7 ���. a �: �t:� : ... y ;rn m ...0. �. i �i I`�� �-1 . O.. ATH3U i H31 I. HJ ! RH211 H2l IN, , , .... . ...._.. `" O .. �. o,i �35 B36 t D36 ) ( D36 ) LB36 ) i B36 ; .. �y . m �' ��� , p, . ,,.m . .� pp ,r - _ _ _ - ,J ,V .. . _ . . _ __ Ll .; ... oo e m. . � oo ' w : � " �i N � � N � N H � �� � �(°� BIS, B35 1 B35 �(�B35_) I B35 i� 635 �� 61 � w: �., w ��_ W �. .w . w,. : I� w� m w_�..0 p w.�:C �y n. :.y � w�. �, '.� �.. N N F� �� � � 5 N3_) �_H3 )( Hl_! � H3 1 H3 Ixl�:� ,' � lo y �. . _ __ _ _ X � . o: m . m . .. � .,. . ,c �o v �o .o �� 6 r.� ¢ " - .. . _ _ . . TOWELS . . . _ _ � INFANTFEF.DING y. y N � .:.. "� . .. � v, ,<„ � � - - - - � � �°'� � � FeFotNG... � o o � p s I d � d d �d d u o c� u i. I �� r r i c a F E ^ a.�:� , a:_�� � . . �. � � .. � � ._.6 � .O p �.� � � j0� I� m 's S � � � y N SHLETS BLNKT! ULTS7fIROWS:.3 �� a s rcavaitns E `� O O O ( HB 1 A8 'H12G� 'H126� }I21 I X d�� d� � d-- � � c7 � u o 3 �c� o s -r- t� -H c� ( B,� 11 �: �.,I � , - .. _ a a _ y � . ---_- . . H51 ) ( HSf' � H51 � � H51 HSl 1 � � I�l Iml I�I I�l I�l I�I ,_ � � � �� � �� �' II .. . _. ._ �y ..�BEDDiNG -x ���'' °� �"� �"� �"i �"� �"� I"I m�" " �� � m w w m m m t-� Q � BEDDING - �^�) SWING AR HI-CIIAIRS.. .�3 23 ,,, _ _ . I� BL'�LY . .. H51 )( H51 � l HSI ; H51 H51 i� .:.�� STROLLERS . w �_ I � �� i�._� �� H71 ..H7 �� H7 i�.HI29r H129 IbI,Q � ;. Iml � a a. I rv U N � N _, a _ . +� � DRAPeS DHARDWARE 57 � � ���� � S � � - I�) I�I � I�I Im I�I = .W-� � I -: -�� � �. � TOSS DMAT. ACC. - - - m : I�I W a I� Im� mw. . m i� n n� m� .. w : w � f,,� � I': w �. �:. � w . a m.. µ, � W.: w'�� w�� . - BI261 (H126� i1i126� ( 113 i f13_ � �' ,. I�,. m�N I�I- I l l I,1 .1�1 ImI : N __. _ . . ` .. . __ �,.. � . . �- .. .. _ . ' �.-. . , : � e� • H25 ' �� H25 � r H25-� � HIS i HIS.. �5 .._ . _ _ ._. ..,. t _ : .� CARSCATS .� i I _ ' ,.. ' , �.... .:..� URM7'QgE LAMPS rn _ ,. ,:.... , . � , :x i'�. : , F �, , § F �'. I�I • :' N., :' 3'. .' .. � �; < : :; ` WALL _ ' � � CRIBS . � . j t` I . � �, � -� .:: ;: x :; , ` � �... � FRAMES PRAMCSSMALLART . ,,.,I p ..._.. �•� r� I.v N W rv ... .:. :i P. : "� : : ': :� i: ' . �.�: �C .: � HB 1 HS 1 � H41 � 1 H4f 1 H41 , �, M� _ � � _ ; , � , � c ��;� I�, o , _ �, .� M m i ; ; [-� ; t a __ . i w ..� I�+I I�I l�I IwI ,mJ Imi � N „ � > -r , „ . H . � m � � � V-� � ''� - � � '' m - ��Z o ._, � �.�, ._ ._ _ _' _ ._. _� w ; :: o,,, :. w '. I :: w �/ :..w � _. �, , .w . �,. ... w �. µ. ;;y , w -:: m... w F . Hl�; l_Hl 1 ( HI i tH31 I N31 _.I;� '� -. v �I �, rv I�I � �� iM i� I'mi � ' . : . ' ,. . W : ,. � �� M� .:: � O ��� CANDLES FIARAL ... N �m� ��I �m� �ml �m� �m� ca (�I � - .. ;.�, , r I ... O i: . � ... -.: . .. O p:� �. . °i -_ �� � C1FTS �-IOME .. ... AIBS � � ., $. . � . `,Z.-------- I�. W.:; '�, '� .� � �u , _ , ,.�j:: , �: ..� ; I � :.�,. . : y -:: ::� � i.� E'�i d HI261 iH126� �HI26i �HI26i H126�1��p I :.: .: . . . . :: ' �: ., r: :�. v� -:t�+ ,S - � :z ' j:: . .. ,:� �;' � � � � . ..., c - _. .:m ... .:p �..Q ..�. H4 � i H4 ) H4 1 i. H4 i H4 � I�.. : . . :� i.; :: ,I I . ' :: ., `: � . . .. . � . ._.__ .. _ (... . .. . . .. .._ ._ .:Q . _ ..... ...:....._._. .., .._.._. .._._.v. . . ::: � -'�.: � � � � � � �' ���� _� ..;, -� F59 `F8 �� v�� . :- : �- . :m � `:��' w f� �;, ::.o µ, .; �. w � � �SEASONAL _..:V � i w , w v '' w ' w . w w v^ 'o o "' �. . 5 >' � � � ; � a � �' �µ�j � �. . I r- m �' a �, ' � �.3 1: y . . . . :. . . . . : '. � f :N o :�.m m � K.TOWEL�µ� ���� �' i�'� GENERALIiOUSEWARFS .. ��( w�n :,� I' � '�rdi� d ��rdi� d ���d O' �:L1 0 ��1] m �.o`� II4 � 114 i 1[41 i 1i41 II2s. Iq.d �� ' � ..;.... ' ' ... ..� . .Y�. v�, . m .. .�, �, ..�y �, .r� � .o ❑ ..Q � .� . . . � , ;. ,. ��--f}--��r�--1F59. :..FB .. .:..... '�..¢.... � k. `. .�o o �:o o �:o : o �.. �.o o .::�. � I141 114 � Fl78) �H78r F178 l�o , ....:... ...... .,: . _., .. . y Q. y . �?� . ` . . . �� ..�p_.....0.1 �. Rl " t0. � _�:W.. -�..F. .1-� � �� :M t0. .... . . ... . ��...._. � GOURMET PMATS/TCLOTIIS , � . . . � . . SERVEWARE FLATWARE� . F59 � ..FB m � ' � . . � � . . �. . � o H4 ) ( H4 ) l R4_� ( H4 � H126 •¢ _� TM .�_�._ .. . I � �� ��S HS � ! HS / H126� �H126 H12G ��'� - 1-: COATS � � � � �O/SDINNCR UOXDiNNER 6 ... - '. .. .:..�. ....�:•-. . � � � ��� ��. �f .3- F59 � :FB I � ��� • I � I 3 � 6AKCWARE GnflG�[S VR{j �� O� O� �..Q� I � I �'Q , . :. ' � . . :�� . ; - h �' °� °� °� °� �' H6 . H6 ) i H28 � � H28 1 HB ��. .. .. � � w I 'w � ��w. `w I � w w . w �. w' w; w.i a �: w��: w= - - . J: � . . �. :� , I �.. .. , . �. . ..�..�., . :: ; � I .,i ': i i H33 i � H33 � H126 IS p �s H37 � 1tf31 I�.O ���` ��� � � �: � �� i�� � ;.; *, � � � �. + � s{��. � �' � � � s, � SII xi EXISTING DOUR TO EXTRA SPACE ' x� (WNLDED SAUT) � �.�.� � i �� - \ \ � � �'x, � � \ \ � � � . � ._.._._ ._...... '... ., ... �, 'I �i � : x; �I \ \ M� -..., fc'7 ....`� � ��.... _ ',......./ �I � � F59 � :F8 � I I I �� S � � � I f I COOKWARE CUTLERY U� V,iN 1 . � � i ¢w x _ i � I ' � � I - �. �. . Z" I a WGGAOB .i�i w �'_ 1 . � . Cn �� I . W . �. �.' . � . � ' 'v H90 ! f A90 i f H90 ! ; H90 i H90 � I� � m � �,� ^!. ... �i;, q... .--• F59�. ,.,....... `F8. .,�......_ w I .. '!� . �[�].. m .9 � .�. w H � W � � LL W .. . u' ;. w ��. W .s w : � w �� � w �:� H90 � ! H90, � H90 I � H90 i N90.. � .._ v� �x � ..,. � ��,��; , :�::: . .::�- . �::. ' �I ; l•... ;P 2: � ,.. �� � :. l ,:: :.._.�' I: ... � I 'U :(. . �� LUGGAGB ...� ��� z . �i � �������� i �I �:� a: � � A � ��t � p] '� cucaace c �/ SH32 SH32 SH32 �SH32� Bt132�� �SH32� �SH321 - , � ' ev R90 �( H901 1 H90 )� H90 ) N90 � til � SH32 SH32 SH32 �SH3b �.SH32i ;SIIJ2' SH32� I � I - . .:: � � I ��Z y' � N90 1( H90 i i H90 i� H90 l H90 I� a � ��I u. ' �. w '. w ' : w '. �w i+. w w � w � �c : w 1 w ' w �� LUGcnce- � � "'• I I I I a " SN32 SH32 SH32 "SF132� BFI32� �SH32i �.SH32� � � �� � � SH32 SII32 SH32 iSH321 �SH32� �;SH32i ,SH32% � . � s � � �.SH3b �SN3L �SH32�� �Sp32i SH32 SFI32 � , m . � . . ; , �.i �� � . ' � NI I I �� �� j I - I '�' . : :f :; � .. �� ' � '� � '.51132� ,SH3b �$II32� �St132i SIU2 SII32 ; a WOMEN'S SHOES _ � � yl SH32 SH32 SH32 i5H321 i5H3b '51132� �SH3D � - � � � �. �� � ��0�� j" ' = SH72 SH}2 SEil2 13I3321 Bi132�� BH3L �SIi3D . . . � . +SHJ2! �9H3D �SH32� �SH32� SH32 SH32 :� �^ �. :��� � � . . 3H32� ��SH32� SH32i �SH32� SH32 SH32 � a � �� 3 291 umt ca act �' � 1,700 umt capacity , , P �tY ( � � SH32 SH32 SH32 ISN3L SH3L ��SH32� !SH32r �� - ' �{ � � . �•' SI....-.......� SH32 SH32 SH12 ��SH3L ' , �-�' � ��E� .... .. .- � . .... �SF132� �SH32� .�SH321 •5H32i SH32 SH72 _.._. ` i . � � vil � i5H32;. .,SN32! ��SH32: .:. ...I . . .. , a �., s.. , , :. _. � . :. ...... � I 32 � . SH32 �SfU2� �SH32 �SH32� SFI32 SH ;% � . � ' ., . . � al - . � . �: :: . j� z w I�W -w: -w' �. w w W w w. W w __ __- ' � .n SH32 SH32 SH32 f5H321 �SF1321 ISIU2i �SH32�� � � � . W �� � I �'" 5 51132 SH32 5f132 �,Sk13D �SH32� tSH32� �Sfi32i I, � � I . FS F8 � �� � I '� � � � � _ y� % d ���,,,/// OUTERWEAR �i� yl � SN32 SH32 SH32 (SH32i iSH321 �SH3D �SH32'� I �: , � . � , . �.. �:;: , ; � -:. � I :::. _ '_' ' = SH32 SH32 SF132 iSF132� �SH32� �,SH32! •.SH32i , NI �������� w_�I w -w � a W w ' w w �. w w � w�� n w w: I w . .FB , FB .. . HOSIERY SOCKS _ � �� � N � ,a�� C� iD4} iD4i iDM1 l D41 lD4] 1D4� �� WI : 1�� Q � �. Ri ���� � �I i �Q '.. D4 i� D4 1 1 D4 � D4 1 D4 � D4 � py � I"� .:. � jnSa _ O �' � i Q�., .:�� ', I v� : q; ,, � I '�� : ' � � y _ EXERCfSE COSMBTICS � � 'I � , Ll� I . " ' " I+. �: .. I '� i+� � � i�. Y1 �: w . ' W , H• ' • w W � . ... W �� . w � w �� w � I W . .. .. . . _ l. . ��� t D31 �� IDJI�+ �.D31 �i� (-D31 �i tD31 i �-0ll ! � -. , ,.. a - � � � � � � ��� �' :� : . .� �j :: � ' :.: . ' W � _ .., .. : ... j .. - � �.. . .:.... . . , . ......... �$ _ ._. Fa ..,. i i D4 i l D4 ;� D4 1 l D4 � l D3i ��. DSI i O �Q � j 0� � �y - UEAUTY ACC. WSMLTICS � �- I, � 1 �� �� I F8 F8 l - -�.� }IAIRTOOLS HAIRCARE SKINCARE �� �� �/� Q� i°i �Q 1 D4 1� DB 1( D8 1 1 D8 i DS �( D8 r . �. I:� . � �� I � TAILO�'D '� � .� !� m iD81 �DBi tD8 lD8 � � DS! � D81 {� � , � AI ' . .._ VbT1 DATHHANDBAG � �� � �� � ..� ..� � �. �l�l.� � �: ��--j�:: � -�.� � � '� ^':'-1 _' � �! 29 �� Dl � L DI 1 l Dl i I DI ) 1 DI 1 Eq ,� '�. DI � i DI !� DI i i DI ) I DI �� DI ) x . . � �I ACCESSORIES BAGS y 9. �.M19-� :Mlf �M17�. 17 ) � � o) � i DI i� DI �: DI 1( Dl ) 1 DI i f DI ) 1 DI �,v� ��' .��w"7' t+ �=' �- ,.� v� � .�c� .. � a 'j� :: �IAi 29� �D29r �.Dli �Dl iDli lDl) �DI�Q �� •i�i�� �ii� �� m �ryi.i� ��io i+avi ���� C � WALLETS FIANDDAC� � � � , � � O1 � .' �) fl �i H I �: II 1 � II U �. II U � N-... y N. N�... - i.�MIL .. � :: , � _. .. cosnm+e.reweLnv .. Qy � . _ ..a .' : q � � o _. o � � o. _.... _� � � � __. V o o � -� � z N .. � I � i D29 � D27 r D27 i D27 r � D27 � D27 � 0 I .. ... .... ',.�' �� 1 27 1 i D27 �( D27 1. D27 1 i D21 ��. D27 � D27 �,�,� w . �j . .... � f �:, O�� p�� G [Z�p Z.� � ., . w ee m m rv v� �o c o 0 0 "�° � f '.:. EOXED7EWELRY COSTUML�JCWGLRY � � � i 1 ..� � � � � � � %� � � � � N� �N � � � Qi �� � . ' . � � M.19) ;`MI9i !M2•3 iM21`� (M17�� _ _M72�i -,� WATCHPS 7EWEIRY �UN. ���+1111 �I f� �.. 17 r � D17 � i D29 )! D29 ) t D29 i. D29 i� 3 . � C� �� F'UR.�.S�'TINCT.S MEN'1.7 •' a ; rv� �Iq i ID i i DIO � t DIO i�. D4 � 1 D4 i � D4 1��� 40CART3 D . o wc noH . NDL'RWOAR _ -" RUANNAS COLD WEATFIER- � � :. .. .. ., M31 ( M3 1 �l ! ( M3 ) M3 i. ( M3 � ( Ml j � -.� J . ,..: . . . .. . . . -- -'_ __- . , �: � :. + � 149R I49R � 149 I 9R � {J92 f49R k.9R "-. � M3 ) M3 M3 �I 9 � � � � � " � � � (R43 � R43) ( R43 � RA3_? . / a HA7S OLDWHATHHR,-. �nox� �; `: O� D6 1 t D6 J( D6 i D8 1 l DS � I DS 1 0,� ' ' � . 6 . S 4 �� 3 2 � -. - � , �. �'�� ` D6 � t D6 � 1 D6 � �3 � � Dl0 � i DIO i � '� � � �� � o� � t�nrs HNR B��rs � ". ' STORAGE CASH COUNT , ' � ncc. ct�cc�courmEE�varr � �) scnavcs VESTIBULE "u�e"9_ a�„: """°°" �� - � � _ . o __ _ , ���_� , i��. D24 x D24 :i: D241:;1 D� D24 �;��.1, D241 i� D24 ��. ; CH41 :�'Sd� C 3� C J�' C 3. ' ; F56� � CI�I41 R71 (�R7_) f_ R7 1 �,R7 ,. R7 1 � , __ . ., � CH45 CH45 .. . . . . 8'-3�� 8�_3�� EXISTING 8" FIRE RISER J i. .. . : , � � , ' , , ! �; /' �� � � x � �, � i ' � � ���h � ���'� 3 � � .; s � �.ti r, �fi `�'s. ��`. � � ``�. "s ' • 1 SPRINKLER ROOM O � RECEIVED CITY O� TUKWILA JUL 20 2016 PERMIT �;�NTER :,�# ' �. �5'.' /` a,s � � _ /.Y a EXPIRES STORE NO: �� 1;#� y , ` � 9.� ��``��' � f <;� x o c��{�s } + . ;'s; �ik�: �.. vt i t�' u, ����.��r���f�� t�-0���r����� .�fR+�2�� ��r.�, � • � ���� •• i;�b,;.;atakrsidv,� 4ir%,+�"` � � _ ���s;� �`, • � x. . � �� •. ���� .� -n ai;sy`���,i t� rd?� �� _ '�{��&��,�"1�1A1`� 3k� : "�Sl�t s` � �`b` • � � ��'h�b,,,�a+��s.,;,�:�'�'o�c:r�` � � ��, � $a'f,�twt"�tb3is„;�tt§ , 'i2�s.���M�tit``�%�ti . - _ ���,�; +���> •• 7 �ca�i tl� ik �£3 � ��� � �� �� ,.�,�;�+it�;,a�?�,tt3$ REVI5ION DATE �Revised by reducing and 1 reairanging back of house 9/24/2015 and decreased tile aisle width to 6'-0". �Revised to single slider 2 entrance, added a register, ] 0/23/2015 decreased stornge room & adjusted front tile. Relocated baby kiosk to be on wall. �• Added perimeter aisles. 3 • Relocated baUy kiosk to 1/04/201G corner. ISSUED DATE PRELIM. DISTRIBITTION 9/17/2015 REVISED PRELIM. DIST. 9/23/2015 REV.2 TO LANDLORD 10/26/2015 PURCH. 5/19/2016 DRAWING TITLE: FIXTURE PLAN DRAWNBY : TLA CHECK.IIY : DDP SCALE ASNOTED DATE 8/]0/2015 2" O.C. 1 � UPRIGHT 3/4'' \ / 1 1 /2�� � � � � �� 0 .� GA. 5 � HORIZONTAL BRACE (SPREADER) 1 1/2"Q� HOLES 2 � ANCHOR PLATE Vp � 16 GA. ATi'ACH UPRIGHT TO ATTACHMENT PLATE W/#10x3/4"HEX ��` HEAD S.M.S. � l � 6"0 HOLES VARIES " X 14 GA. STRAP �ACH W/ 10 x 3/4" :X HEAD SCREW (4) REQ'D PER X-BRACE SET VET AT CENTER SEE ELEVATIONS FOR X-BRACING CONFIGURATION 6 � SIDE & REAR X-BRAC�iVG 2 1 /2" � MIN_ EMBEDMENT �r (1) REQ'D PER ANCHOR PLATE 3 � ANCHOR 4TTACH W/ #10 x 3/4" MIN.) S.M.S. (3) EACH PER BACK TO BACK POST LOCATION ' � BACK TO BACK ATTACHNIENT DETAIL 16GA /� � � .��� J 1 1 /2" � � � ' � � � � 0 � 0 � � � � � � � � � � � � �� �� TOP TIE f� , I-- , 45,64 4 � SHELF GENERAL CONFIGURA�'�ON (SHELVING) NOTES: 1 2 3. 1 1/2" � �� 4. 5. TOP TIES ARE TO BE LOCATED AT EACH END , ALSO EVERY �THER UPRIGHT IN BETWEEN, BUT NC�T TO EXCEED 8'-0" APART. AT INTERMEDIATES, FASTEN UNDER TOP SHELF. USE #10x3/4 SCREW TO SECURE THE TOP TIES TO THE UPRIGHTS. (AS SH�WN) SLAB CONCRETE STRENGTH = 3000 PSI MINIMUM STEEL STORAGE RACKS DESIGNED IN ACCORDANCE WITH 2O12 IBC ANCHORS INDICATED ON DETAIL AND SHALL BE: POWERS FASTENER WEDGE BOLT (ICC-ES ESR 2526) HILTI KWIK BOLT TZ (ICC-ES ESR 1917) OR ICC-ES APPROVED EQUAL MINIMUM DISTANCE BETWEEN ANCHOR BOLT CENTER TO ANY CONSTRUCTION JOINTS, CONTROL/EXPANSION JOINTS OR SLAB CRACKS IS 4" PROVIDE SPECIAL INSPECTION FOR EXPANSION ANCHORS IN ACCORDANCE WITH IBC 1707.05 �--------� I ��� ��� � ' ' � � � . � � ' I, � u LOAD CAPACITY PER SECTION 350 LBS �"'�,j�, S T� ?� aF ���"� � , p� ti� , �p� > �•. •�+� �a �~, • EXPI RES 1 CALCULATIONS BY: w� , � ��: � _�� � y � ,<. L���,,�4�.�4.��,� :�`,.% ������',�i��.�� ������ �'�'�� :�� �:� �c�����il+���� �`����t. �t��t� i�7� ����l,1������. '�'��� �.��1� a�'.����£ 1��-.,. ��4��.� ��.F9,.^L.< ��L=.P f x'''��li�,�. �. �:���.��i��. .i����k.°}����i�l�.`c��.��4�,.ri.����,.Pe~.� �.1.�: � RECEIV�D CITY C)F TUKWILA JUL 20 2016 IP�RMIT CENTER WARNING: THIS DRAWING AND THE IDEAS PORTRAYED IN IT, ARE THE PROPERTY OF THE MERCHANDISING EQUIPMENT GROUP, LLC. THIS DRAWING SHOULD NOT BE COPIED OR DISTRIBUTED WITHOUT THE EXPRESS PERMISSION OF AN AUTHORIZED MEG EMPLOYEE. ADDRESS: BURLINGTON COAT 17480 SOUTHCENTER PKWY TU KW I LA, WA. 98188 shop � . MEG Merchandising Equipment Group, LLC. 502 South Green Street, Cambridge City, Indlana 47327-0240 TITLE: SHELF SPACE SHELVING SHEET 1 OF 1 DRAWING NUMBER: CALC535 A