Loading...
HomeMy WebLinkAboutPermit D16-0207 - ORCAS HOMES - FOSTER LANE LOT 7 (NULL)FOSTER LANE -LOT 7 14407 44T" LN S D16-0207 Parcel No: Address: City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-438-9350 Web site: http://www.TukwilaWA.gov DEVELOPMENT PERMIT 0040000377 Permit Number: D16-0207 14407 44TH LN S Project Name: FOSTER LANE LOT 7 Issue Date: 8/8/2016 Permit Expires On: 2/4/2017 Owner: Name: Address: Contact Person: Name: Address: Contractor: Name: Address: License No: Lender: Name: Address: ORCAS HOMES LLC 12411 NE 80TH WAY DUNBABIN BOB, KIRKLAND, WA, 98033 DAMIAN NORRIS 2053 FABEN DR, MERCER ISLAND, WA, 98040 NORRIS HOMES INC 12411 NE 80TH WAY, KIRKLAND, WA, 98033 NORRIHI099LC COASTAL COMMUNITY BANK 10520 19TH AVE SE , EVERETT, WA, 98208 Phone: (206) 423-2124 Phone: (206) 275-1901 Expiration Date: 5/22/2017 DESCRIPTION OF WORK: NEW DECK Project Valuation: $432.30 Type of Fire Protection: Type of Construction: VB Electrical Service Provided by: Sprinklers: NO Fire Alarm: NO Fees Collected: $115.00 Occupancy per IBC: U Water District: Sewer District: Current Codes adopted by the City of Tukwila: International Building Code Edition: International Residential Code Edition: International Mechanical Code Edition: Uniform Plumbing Code Edition: International Fuel Gas Code: 2015 2015 2015 2015 2015 National Electrical Code: WA Cities Electrical Code: WAC 296-46B: WA State Energy Code: 2014 2014 2014 2015 Public Works Activities: Channelization/Striping: Curb Cut/Access/Sidewalk: Fire Loop Hydrant: Flood Control Zone: Hauling/Oversize Load: Land Altering: Landscape Irrigation: Sanitary Side Sewer: Sewer Main Extension: Storm Drainage: Street Use: Water Main Extension: Water Meter: Volumes: Cut: 0 Fill: 0 Number: 0 No Permit Center Authorized Signature: Date: I hearby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of thi .ermit does n presume to give authority to violate or cancel the provisions of any other state or local law gulating 'a•n truction or the performance of work. I am authorized to sign and obtain this development pe t and a o the conditions attached to this permit. Signature: Print Name: V(�'� I fr Nen_`1�1 S Date: e ---/k This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: ***BUILDING PERMIT CONDITIONS*** 2: Work shall be installed in accordance with the approved construction documents, and any changes made during construction that are not in accordance with the approved construction documents shall be resubmitted for approval. 3: All permits, inspection record card and approved construction documents shall be kept at the site of work and shall be open to inspection by the Building Inspector until final inspection approval is granted. 4: All construction shall be done in conformance with the Washington State Building Code and the Washington State Energy Code. 5: Notify the City of Tukwila Building Division prior to placing any concrete. This procedure is in addition to any requirements for special inspection. 6: All construction noise to be in compliance with Chapter 8.22 of the City of Tukwila Municipal Code. A copy can be obtained at City Hall in the office of the City Clerk. 7: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center. 8: Preparation before concrete placement: Water shall be removed from place of deposit before concrete is placed unless a tremie is to be used or unless otherwise permitted by the building official. All debris and ice shall be removed from spaces to be occupied by concrete. 9: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 1700 BUILDING FINAL** 0201 FOOTING 0409 FRAMING CITY OF TUKR A Community Development Department Public Works Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.TukwilaWA.gov Building Per.=.gt No. DV' 07 '0/ Project No. Date Application Accepted: '1 `lA'r Il Date Application Expires: 1 jr (For office use only) CONSTRUCTION PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **Please Print** SITE LOCATION Site Address: 14407 44th Lane S. Tenant Name: Fatal-C4.41,e/ #-1 PROPERTY OWNER Name: Damian Norris Name: Orcas Homes LLC City: Kirkland State: WA Zip: 98033 Address: 12411 NE 80th Way Email: damian@norrishomesinc.com City: Kirkland State: WA Zip: 98033 CONTACT PERSON — person receiving all project communication Name: Damian Norris Address: 12411 NE 80th Way City: Kirkland State: WA Zip: 98033 Phone: (206) 423-2124 Fax: Email: damian@norrishomesinc.com GENERAL CONTRACTOR INFORMATION Company Name: Norris Homes, Inc. Address: 12411 NE 80th Way City: Kirkland State: WA Zip: 98033 Phone: (206) 423-0777 Fax: Contr Reg No.: NORRISHI099LC Exp Date: 05/22/2017 Tukwila Business License No.: BUS -0996302 H:\ Applications\Forms-Applications On Linc\201 1 Applications\Pcrmit Application Rcviscd - 8.9-1 l.docx Rcviscd: August 2011 bh King Co Assessor's Tax No.: 004000-0377 Suite Number: Floor: New Tenant: ❑ Yes ..No ARCHITECT OF RECORD Name: Coastal Community Bank Address: 10520 19th Ave. SE Company Name: Architect Name: . Address: City: State: Zip: Phone: Fax: Email: ENGINEER OF RECORD Name: Coastal Community Bank Address: 10520 19th Ave. SE Company Name: Engineer Name: Address: City: State: Zip: Phone: Fax: Email: LENDER/BOND ISSUED (required for projects $5,000 or greater per RCW 19.27.095) Name: Coastal Community Bank Address: 10520 19th Ave. SE City: Everett State: WA Zip: 98208 Page 1 of 4 BUILDING PERMIT INFORMATIOI )06-431-3670 Valuation of Project (contractor's bid price): $ 1,500 Describe the scope of work (please provide detailed information): Construct wood deck. Will there be new rack storage? ❑ Yes Existing Building Valuation: $ 190,000 0.. No If yes, a separate permit and plan submittal will be required. Provide All Building Areas in Square Footage Below PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) 1,966 *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact: Handicap: Will there be a change in use? 0 Yes WI No If "yes", explain: FIRE PROTECTION/HAZARDOUS MATERIALS: Sprinklers 0 Automatic Fire Alarm ❑ None ❑ Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? 0 Yes El No If 'yes', attach list of materials and ,storage locations on a separate 8-1/2"x 11" paper including quantities and Material Safety Data Sheets. SEPTIC SYSTEM 0 On-site Septic System — For on-site septic system, provide 2 copies of a current septic design approved by King County Health Department. H:'ApplicationsWorms-Applications On Line \2011 Applications\Permit Application Revised - 8-9-11.docx Revised: August 2011 6L Page 2 of 4 Existing Interior Remodel Addition to Existing Structure New Type of Construction per IBC Type of Occupancy per IBC 1' Floor 1,294 2"4 Floor 1,543 3rd Floor Floors thru Basement Accessory Structure* Attached Garage 588 Detached Garage Attached Carport Detached Carport Covered Deck Uncovered Deck 55 PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) 1,966 *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact: Handicap: Will there be a change in use? 0 Yes WI No If "yes", explain: FIRE PROTECTION/HAZARDOUS MATERIALS: Sprinklers 0 Automatic Fire Alarm ❑ None ❑ Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? 0 Yes El No If 'yes', attach list of materials and ,storage locations on a separate 8-1/2"x 11" paper including quantities and Material Safety Data Sheets. SEPTIC SYSTEM 0 On-site Septic System — For on-site septic system, provide 2 copies of a current septic design approved by King County Health Department. H:'ApplicationsWorms-Applications On Line \2011 Applications\Permit Application Revised - 8-9-11.docx Revised: August 2011 6L Page 2 of 4 PUBLIC WORKS PERMIT INFO ATION - 206-433-0179 Scope of Work (please provide detailed information): Call before you Dig: 811 Please refer to Public Works Bulletin #1 for fees and estimate sheet. Water District 0 ...Tukwila ®...Water District #125 0 ...Water Availability Provided Sewer District ❑ ...Tukwila 0 ...Sewer Use Certificate 0 .. Highline 2 ...Valley View ❑ .. Renton ❑ ...Sewer Availability Provided ❑ .. Renton ❑ .. Seattle Septic System: 0 On-site Septic System — For on-site septic system, provide 2 copies of a current septic design approved by King County Health Department. Submitted with Application (mark boxes which apply): 0 ...Civil Plans (Maximum Paper Size — 22" x 34") 0 ...Technical Information Report (Storm Drainage) ❑ ...Bond ❑ .. Insurance 0 .. Easement(s) Proposed Activities (mark boxes that apply): ❑ ...Right-of-way Use - Nonprofit for less than 72 hours ❑ ...Right-of-way Use - No Disturbance ® ...Construction/Excavation/Fill - Right-of-way 0 Non Right-of-way ❑ ...Total Cut ❑ ...Total Fill cubic yards cubic yards ❑ ...Sanitary Side Sewer ❑ ...Cap or Remove Utilities ❑ ...Frontage Improvements ❑ ...Traffic Control ❑ ...Backflow Prevention - Fire Protection Irrigation Domestic Water ❑ .. Geotechnical Report 0 .. Maintenance Agreement(s) ❑ ... Traffic Impact Analysis ❑ ... Hold Harmless — (SAO) ❑ ...Hold Harmless — (ROW) ❑ .. Right-of-way Use - Profit for less than 72 hours ❑ .. Right-of-way Use — Potential Disturbance ❑ .. Work in Flood Zone ❑ .. Storm Drainage ❑ .. Abandon Septic Tank ❑ .. Curb Cut 0 .. Pavement Cut ❑ .. Looped Fire Line ❑ ...Permanent Water Meter Size... ❑ ...Temporary Water Meter Size .. 0 ...Water Only Meter Size ❑ ...Sewer Main Extension Public ❑ ...Water Main Extension Public 0 .. Grease Interceptor ❑ .. Channelization 0 .. Trench Excavation ❑ .. Utility Undergrounding WO # WO # WO # 0 ...Deduct Water Meter Size Private 0 Private 0 FINANCE INFORMATION Fire Line Size at Property Line Number of Public Fire Hydrant(s) 0 ...Water 0 ...Sewer 0 ...Sewage Treatment Monthly Service Billing to: Name: Day Telephone: Mailing Address: Water Meter Refund/Billing: Name: Mailing Address: City State Zip Day Telephone: City State Zip H:\Applications\Forms-Applications On Line \2011 Applications\Permit Application Revised - 8-9-1 I.docx Revised: August 2011 bh Page 3 of 4 ON Ni Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR AUTHORIZED A NT: Signature: Date: 07/26/2016 Print Name: Courtney Norris Vice p0.es 063rDay Telephone: (206) 423-0777 Mailing Address: 12411 NE 80th Way KirklandWA 98033 H:Wpplications\Forms-Applications On Line \2011 Applications\Permit Application Revised - 8-9-11.docx Revised: August 2011 bh City State Zip Page 4 of 4 Cash Register Receipt City of Tukwila DESCRIPTIONS PermitTRAK 1 ACCOUNT QUANTITY PAID • $115.00 D16-0207 Address: 14407 44TH LN S Apn: 0040000377 $115.00 DEVELOPMENT $111.75 PERMIT FEE R000.322.100.00.00 0.00 $65.00 PLAN CHECK FEE R000.345.830,00.00 0.00 $42.25 WASHINGTON STATE SURCHARGE B640.237.114 0.00 $4.50 TECHNOLOGY FEE $3.25 TECHNOLOGY FEE TOTAL FEES PAID BY RECEIPT: R9056 R000.322.900.04.00 0.00 $3.25 -$115 00 Date Paid: Tuesday, July 26, 2016 Paid By: NORRIS HOMES Pay Method: CHECK 80746 Printed: Tuesday, July 26, 2016 12:10 PM 1 of 1 I . 1J )7SYSTEMS INSPECTION NO. INSPECTION RECORD Retain a copy with permit °tel PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 PCa N5 fIS Type tnacAon: `meq' Address /11(1a7 �i� till- Q Date Called: Special Instructions: Date Wanted: i6)—/746 a.m p.m. Requester: Phone No: Approved per applicable codes. a Corrections required prior to approval. COMMENTS: Inspector: A n REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit 1)16-024 PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 \oN' Project Type of e n:r FIR' C'el l Ar ss�y� 7 ipif,t (0(4P Set Date Called: V Special Instructions: Date Wanted: 8-17 _/,‘ p.m. Requester: Phone No: MApproved per applicable codes. L1 Corrections required prior to approval. COMMENTS: Inspector: Date: n 17,M REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. LJ INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION P16 -02-0 7 6300 Southcenter Blvd., #100, Tukwila. WA 98188 Permit Inspection Request Line (206) 438-9350 (206) 431-3670 \ 64' Pr ct: roS tit "fjj_ Type of Inspec cont ado j� n Address:q/ ilq zoite_ Dia D e Called: t Special Instructions: Date Wmted: a.m. 'Requester: Phone No: Approved per applicable codes. LJ Corrections required prior to approval. COMMENTS: Inspector: Date:* .7Ii REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. PERMIT COORD COPY PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: D16-0207 DATE: 07/27/16 PROJECT NAME: FOSTER LANE - LOT 7 SITE ADDRESS: 14407 44TH LANE S X Original Plan Submittal Revision # before Permit Issued Response to Correction Letter # Revision # after Permit Issued DEPARTMENTS: AAta 1-1Ai Bui ing Division Public Works 0 ANI Kia. '144'. I(i Fire Prevention Or Structural <M2 -AT 6-s* Planning Division II ❑ Permit Coordinator PRELIMINARY REVIEW: Not Applicable n (no approval/review required) REVIEWER'S INITIALS: DATE: 07/28/16 Structural Review Required DATE: APPROVALS OR CORRECTIONS: Approved ❑ Approved with Conditions Corrections Required (corrections entered in Reviews) Notation: Denied (ie: Zoning Issues) DUE DATE: 08/25/16 n REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: 12/18/2013 NORRIS HOMES INC 1=ioOTIC Espanol Contact Safety & Health Claims & Insurance Washington State Department of ILO Labor & Industries Page 1 of 2 A-1, Index Help My 1.&I Workplace Rights Trades & Licensing NORRIS HOMES INC Owner or tradesperson Principals NORRIS, JOHN BRADLEY, PRESIDENT NORRIS, COURTNEY BRYNN, VICE PRESIDENT Doing business as NORRIS HOMES INC WA UBI No. 601 320 348 12411 NE 80TH WAY KIRKLAND, WA 98033 206-275-1901 KING County Business type Corporation License Verify the contractor's active registration / license / certification (depending on trade) and any past violations. Construction Contractor License specialties GENERAL License no. NORRIHI099LC Effective -- expiration 06/03/1991— 05/22/2017 Bond OLD REPUBLIC SURETY CO Bond account no. YLI219775 Active. Meets current requirements. $12,000.00 Received by L&I Effective date 02/16/2002 05/22/2002 Expiration date Until Canceled Insurance Wesco Insurance Co $1,000,000.00 Policy no. WPP1377444 02 Received by L&I Effective date 04/05/2016 05/31/2016 Expiration date 05/31/2017 Insurance history Savings No savings accounts during the previous 6 year period. Lawsuits against the bond or savings No lawsuits against the bond or savings accounts during the previous 6 year period. L&I Tax debts https://secure.lni.wa.gov/verify/Detail.aspx?UBI=601320348&LIC=NORRIHI099LC&SAW= 8/8/2016 25' N 01°08'52" E 77.13' 25' PRIVATE DRAINAGE EASEMENT, N 01°08'52" 20.00' 3„Eb,TS0L8S 12'-1 7-0" 613 N 33'-0" CHELSEA MAIN FLR. 1294 SQFT r— — GARAGE 588 SQFT L11_-8"_� 21'-0" L=31.76' R = 20.00' SCALE: 1" = 20' 10' SIDEWALK UTILITY E T. co 2 c?. N01°08'52"E 36.70' 44TH LN. S. 2 x 4 CAP RAIL 1 x 4 TOP RAILS 4 x 4 POST SPACING 8' O.C. MAX. - 1 x 4 BOTTOM RAILS <4"O M —2 x 2 PICKETS (2) (1)DTT2ZBERRTS POST SCALE: Z" = 1' 2'k8"DECK JOIST `4 x 4 CEDAR DECKING z 0 v Lu c")W 0 W U D FLASHING 1 /4" 0 x 4-1 /2 SIM PSON SDS SCREWS, 8" O/C STAGGERED TOP & BOTTOM (2) DTT2Z's w/ %" THREAD ROD TIE DECK TIE BAC (2) LOCATIONS SCALE: 1" = JST. HANGER 2 x 8 LEDGER u A A RIM JST. BLOCKING DOUBLE P.T. 2X8 JOIST USE 4" X 4 CEDAR DECKING, TYP. HANDRAIL (SEE DETAIL) 2X8 P.T. BLOCKING OVER BEAM 18" CONCRETE PIERS (TYP.) 4X4 P.T. POST W/ABU44 POST BASE HANG JOIST FROM LEDGER W/ LUC28Z SCALE: 1/" = 1' X8 oIs1 a 16" Ic 2 0 HOUSE 7' HA w HAP O z —4X10 HA 8' 0.C. ( Max.) POSTIVE DIRECT CONNECTION TO RESIST UPLIFT & LATFRAL DISPLACEMENT (1x4 CLEATS FRONT & BACK) 4 x 4 P.T. POST POST ANCHOP TO RESIST UPLIFT & LATERAL DISPL ACEMENT (ABU44) 18" X 18" X 12" OONCRETE PIER SCALE: 1/ = 1' G DBL JOIST W/ SKEWED LUC28-2Z G JOIST W/ SKEWED LUC28-2Z P.T. BEAM NG BEAM HUC4 10Z i-SEFARATE7 PERMIT i *Z ?UIRED FOR �'INNcchanical Q icctrical E iumbing Lrl,Las Piping 1µ::W of Tukwila E' ii 7,..'f!'!21 DIVISION PL.ANN§"#8, . PE Rs-'. .PED . e'. � � > ? fix. ��-Y, No changes .co..n b rnelde. to these plans without approval from the Planning 'Division of DCD ,w Approved By: 1 EL) SCALE: 1/a" = 1' 7' 4 x 10 P.T. BEAM GRADE REVISIONS f !o changes shall he made to the scope of work without prior approval of T ukiv;la Building Division. N712. =: i,evis ons will require a new plan submittal and may include additional plan reviewfeed Permit No. t0" C).?47 Plan review approval is subject to errors and omissions. Approval of corisinuction documents does not authorize the violation f arr.. adopted c d , or ordinance. Receipt of approved Field. .py andi ';iticns is acknowledged: 3y: Date: City of Tukwila BUILDING DIVISION REVIEWED FOR CODE COMPLIANCE APPROVEI AUG 0 4 2016 City o i c [ops t¢z BUILDING DIVISION NOTES 1. ALL MATERIAL EXPOSED TO WEATHER SHALL BE PRESSURE TREATED OR NATURALLY RESISTANT TO DECAY 2. "FIELD -CUT ENDS, NOTCHES AND DRILLED HOLES OF PRESERVATIVE -TREATED WOOD SHALL BE TREATED IN THE FIELD IN ACCORDANCE WITH AWPA M4." R319.1.1 FIELD TREATMENT 3. "FASTENERS FOR PRESSURE PRESERVATIVE AND FIRE -RETARDANT -TREATED WOOD SHALL BE OF HOT -DIPPED GALVANIZED STEEL, STAINLESS STEEL, SILICON, BRONZE, OR COPPER." PROJECT NAME: FOSTER LANE LOT #7 ADDRESS: 14407 44TH LN. S. DECK 55 SQFT. DRAWN BY: Damian Norris RECEIVED ITV OF TUKWILA JUL 2 6 2016 'ERMIT CENTER DATE: 7/26/2016 SCALE: VARIES SHEET Di