Loading...
HomeMy WebLinkAboutPermit D16-0210 - CRISPY TOWN - TENANT IMPROVEMENTCRISPY TOWN 1379 SOUTHCENTER MALL EXPIRED 10/03/17 D1 6-021 0 City of Tukwila • Department of Community Development • 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-438-9350 Web site: http://www.TukwilaWA.Rov DEVELOPMENT PERMIT Parcel No: 9202470010 Permit Number: D16-0210 Address: 1379 SOUTHCENTER MALL Issue Date: 2/14/2017 Permit Expires On: 8/13/2017 Project Name: CRISPY TOWN Owner: Name: WESTFIELD PROPERTY TAX DEPT Address: PO BOX 130940, CARLSBAD, WA, Address: 1379 SOUTHCENTER MALL, TUKWILA, WA, 98188 DESCRIPTION OF WORK: Phone: (206) 420-2242 Phone: (951) 774-0677 Expiration Date: 11/30/2018 TENANT IMPROVEMENT FOR NEW RESTAURANT Project Valuation: $65,000.00 Fees Collected: $1,946.32 Type of Fire Protection: Sprinklers: YES Fire Alarm: YES Type of Construction: IIB Occupancy per IBC: A-2 Electrical Service Provided by: TUKWILA Water District: TUKWILA Sewer District: TUKWILA Current Codes adopted by the City of Tukwila: International Building Code Edition: 92013 Contact Person: 2014 Name: PATRICIA SHELBY Address: 5628 AIRPORT WAY S, STE 112, International Mechanical Code Edition: SEATTLE, WA, 98108 Contractor: 2014 Name: WEST COAST CONSTRUCTION Address: 3400 CAPITOL BLVD - SUITE 101, International Fuel Gas Code: OLYMPIA, WA, 98501 License No: WESTCCC848Q1 Lender: Name: CRISPY TOWN Address: 1379 SOUTHCENTER MALL, TUKWILA, WA, 98188 DESCRIPTION OF WORK: Phone: (206) 420-2242 Phone: (951) 774-0677 Expiration Date: 11/30/2018 TENANT IMPROVEMENT FOR NEW RESTAURANT Project Valuation: $65,000.00 Fees Collected: $1,946.32 Type of Fire Protection: Sprinklers: YES Fire Alarm: YES Type of Construction: IIB Occupancy per IBC: A-2 Electrical Service Provided by: TUKWILA Water District: TUKWILA Sewer District: TUKWILA Current Codes adopted by the City of Tukwila: International Building Code Edition: 2015 National Electrical Code: 2014 International Residential Code Edition: 2015 WA Cities Electrical Code: 2014 International Mechanical Code Edition: 2015 WAC 296-46B: 2014 Uniform Plumbing Code Edition: 2015 WA State Energy Code: 2015 International Fuel Gas Code: 2015 Public Works Activities: Channelization/Striping: Curb Cut/Access/Sidewalk: Fire Loop Hydrant: Flood Control Zone: Hauling/Oversize Load: Land Altering: Volumes: Cut: 0 Fill: 0 Landscape Irrigation: Sanitary Side Sewer: Number: 0 Sewer Main Extension: Storm Drainage: Street Use: Water Main Extension: Water Meter: No Permit Center Authorized Signature: W Date: I hearby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this development permit and agr to the conditions attached to this permit. /f Signature: _f ) `/vL__� Date: Print Name: i \� V ---jL la C 1/0^v ✓GL This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 4: The total number of fire extinguishers required for an ordinary hazard occupancy with Class A fire hazards is calculated at one extinguisher for each 1,500 sq. ft. of area. The extinguisher(s) should be of the "All Purpose" (3A, 4013:C) dry chemical type. Travel distance to any fire extinguisher must be 75' or less. (IFC 906.3) (NFPA 10, 5.4) 5: Portable fire extinguishers shall be provided within a 30 -foot (9144 mm) travel distance of commercial -type cooking equipment. Cooking equipment involving vegetable or animal oils and fats shall be protected by a Class K rated portable extinguisher. (IFC 904.11.5) 1: Portable fire extinguishers, not housed in cabinets, shall be installed on the hangers or brackets supplied. Hangers or brackets shall be securely anchored to the mounting surface in accordance with the manufacturer's installation instructions. Portable fire extinguishers having a gross weight not exceeding 40 pounds (18 kg) shall be installed so that its top is not more than 5 feet (1524 mm) above the floor. Hand- held portable fire extinguishers having a gross weight exceeding 40 pounds (18 kg) shall be installed so that its top is not more than 3.5 feet (1067 mm) above the floor. The clearance between the floor and the bottom of the installed hand-held extinguishers shall not be less than 4 inches (102 mm). (IFC 906.7 and IFC 906.9) 2: Extinguishers shall be located in conspicuous locations where they will be readily accessible and immediately available for use. These locations shall be along normal paths of travel, unless the fire code official determines that the hazard posed indicates the need for placement away from normal paths of travel. (IFC 906.5) 3: Fire extinguishers require monthly and yearly inspections. They must have a tag or label securely attached that indicates the month and year that the inspection was performed and shall identify the company or person performing the service. Every six years stored pressure extinguishers shall be emptied and subjected to the applicable recharge procedures. If the required monthly and yearly inspections of the fire extinguisher(s) are not accomplished or the inspection tag is not completed, a reputable fire extinguisher service company will be required to conduct these required surveys. (NFPA 10, 7.2, 7.3) 6: Maintain fire extinguisher coverage throughout. 7: Egress doors shall be readily openable from the egress side without the use of a key or special knowledge or effort. (IFC 1008.1.8.3 subsection 2.2) 8: Exit hardware and marking shall meet the requirements of the International Fire Code. (IFC Chapter 10) 9: Exits and exit access doors shall be marked by an approved exit sign readily visible from any direction of egress travel. Access to exits shall be marked by readily visible exit signs in cases where the exit or the path of egress travel is not immediately visible to the occupants. Exit sign placement shall be such that no point in an exit access corridor is more than 100 feet (30,480 mm) or the listed viewing distance for the sign, whichever is less, from the nearest visible exit sign. (IFC 1011.1) 10: Every exit sign and directional exit sign shall have plainly legible letters not less than 6 inches (152 mm) high with the principal strokes of the letters not less than 0.75 inch (19.1 mm) wide. The word "EXIT" shall have letters having a width not less than 2 inches (51 mm) wide except the letter "I", and the minimum spacing between letters shall not be less than 0.375 inch (9.5 mm). Signs larger than the minimum established in section 1011.5.1 of the International Fire Code shall have letter widths, strokes and spacing in proportion to their height. The word "EXIT" shall be in high contrast with the background and shall be clearly discernible when the exit sign illumination means is or is not energized. If an arrow is provided as part of the exit sign, the construction shall be such that the arrow direction cannot be readily changed. (IFC 1011.6) 11: Each door in a means of egress from an occupancy of Group A or E having an occupant load of 50 or more and any Group H occupancy shall not be provided with latch or lock unless it is panic hardware or fire exit hardware. (IFC 1008.1.10) 12: Exit signs shall be illuminated at all times. To ensure continued illumination for a duration of not less than 90 minutes in case of primary power loss, the sign illumination means shall be connected to an emergency power system provided from storage batteries, unit equipment or on-site generator. (IFC 1011.6.3) 13: Every room or space that is an assembly occupancy shall have the occupancy load of the room or space posted in a conspicuous place, near the main exit or exit access doorway from the room or space. Posted signs shall be of an approved legible permanent design and shall be maintained by the owner or authorized agent. (IFC 1004.3) 14: Emergency lighting facilities shall be arranged to provide initial illumination that is at least an average of 1 foot-candle (11 lux) and a minimum at any point of 0.1 foot-candle (1 lux) measured along the path of egress at floor level. Illumination levels shall be permitted to decline to 0.6 foot-candle (6 lux) average and a minimum at any point of 0.06 foot-candle (0.6 lux) at the end of the emergency lighting time duration. A maximum -to -minimum illumination uniformity ratio of 40 to 1 shall not be exceeded. (IFC 1006.3.1) 18: Fire protection systems shall be maintained in accordance with the original installation standards for that system. Required systems shall be extended, altered or augmented as necessary to maintain and continue protection whenever the building is altered, remodeled or added to. Alterations to fire protection systems shall be done in accordance with applicable standards. (IFC 901.4) 16: Sprinklers shall be installed under fixed obstructions over 4 feet (1.2 m) wide. (NFPA 13-8.6.5.3.3) 15: All new sprinkler systems and all modifications to existing sprinkler systems shall have fire department review and approval of drawings prior to installation or modification. New sprinkler systems and all modifications to sprinkler systems involving more than 50 heads shall have the written approval of Factory Mutual or any fire protection engineer licensed by the State of Washington and approved by the Fire Marshal prior to submittal to the Tukwila Fire Prevention Bureau. No sprinkler work shall commence without approved drawings. (City Ordinance No. 2436). 19: A fire alarm system is required for this project. The fire alarm system shall meet the requirements of N.F.P.A. 72 and City Ordinance #2437. 21: Maintain fire alarm system audible/visual notification. Addition/relocation of walls or partitions may require relocation and/or addition of audible/visual notification devices. (City Ordinance #2437) 20: All new fire alarm systems or modifications to existing systems shall have the written approval of The Tukwila Fire Prevention Bureau. No work shall commence until a fire department permit has been obtained. (City Ordinance #2437) (IFC 901.2) 22: An electrical permit from the City of Tukwila Building Department Permit Center (206-431-3670) is required for this project. 23: All electrical work and equipment shall conform strictly to the standards of the National Electrical Code. (NFPA 70) 24: The maximum flame spread class of finish materials used on interior walls and ceilings shall not exceed that set forth in Table No. 803.9 of the International Building Code. 25: New and existing buildings shall have approved address numbers, building numbers or approved building identification placed in a position that is plainly legible and visible from the street or road fronting the property. These numbers shall contrast with their background. Address numbers shall be Arabic numbers or alphabet letters. Numbers shall be a minimum of 4 inches (102mm) high with a minimum stroke width of 0.5 inch (12.7mm). (IFC 505.1) 26: In occupancies of Groups A, E, I and R-1 and dormitories in Group R-2, curtains, draperies, hangings and other decorative materials suspended from walls or ceilings shall be flame resistant in accordance with NFPA 701 or be noncombustible. Where required to be flame resistant, decorative materials shall be tested by an approved agency and pass Test 1, as described in NFPA 701, or such materials shall be noncombustible. Reports of test results shall be prepared in accordance with NFPA 701 and furnished to the fire code official upon request. (IFC 807.1, 807.2) 17: Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (City Ordinances #2436 and #2437) 27: Any overlooked hazardous condition and/or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. 28: These plans were reviewed by Inspector 511. If you have any questions, please call Tukwila Fire Prevention Bureau at (206)575-4407. 29: ***BUILDING PERMIT CONDITIONS*** 30: Work shall be installed in accordance with the approved construction documents, and any changes made during construction that are not in accordance with the approved construction documents shall be resubmitted for approval. 31: All permits, inspection record card and approved construction documents shall be kept at the site of work and shall be open to inspection by the Building Inspector until final inspection approval is granted. 32: New suspended ceiling grid and light fixture installations shall meet the seismic design requirements for nonstructural components. ASCE 7, Chapter 13. 33: Partition walls shall not be tied to a suspended ceiling grid. All partitions greater than 6 feet in height shall be laterially braced to the building structure. Such bracing shall be independent of any ceiling splay bracing. 34: All construction shall be done in conformance with the Washington State Building Code and the Washington State Energy Code. 35: All food preparation establishments must have Seattle/King County Department of Public Health sign -off prior to opening or doing any food processing. Arrangements for final Health Department inspection shall be made by calling Seattle/King County Department of Public Health, (1-800-325-6165 ext 9-566), at least three working days prior to desired inspection date. On work requiring Health Department approval, it is the contractor's responsibility to have a set of plans approved by the agency on the job site. 36: Fire retardant treated wood shall have a flame spread of not greater than 25. All materials shall bear identification showing the fire performance rating thereof. Such identification shall be issued by an approved agency having a service for inspection at the factory. 37: Special inspection for sprayed fire-resistant materials applied to structural elements and decks is required. Special inspections shall be based on the fire -resistance design as designated in the approved construction documents. 38: All rack storage requires a separate permit issued through the City of Tukwila Permit Center. Rack storage over 8 -feet in height shall be anchored or braced to prevent overturning or displacement during seismic events. The design and calculations for the anchorage or bracing shall be prepared by a registered professional engineer licensed in the State of Washington. Periodic special inspection is required during anchorage of storage racks 8 feet or greater in height. 39: There shall be no occupancy of a building until final inspection has been completed and approved by Tukwila building inspector. No exception. 40: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of this requirement. 41: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206-431-3670). 42: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center. 43: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 44: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431-3670). PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 1700 BUILDING FINAL" 0301 CONCRETE SLAB 0611 EMERGENCY LIGHTING 1400 FIRE FINAL 0409 FRAMING 0606 GLAZING LATH & GYPSUM 0406 SUSPENDED CEILING CITY OF TUKWILA Community Development Department • Public Works Department • Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 h!!p://www.TukwilaWA.gov Building Permit No. D* - Vv o --o Project No. �{ — Date Application Accepted: ' I '!i IV Date Application Expires: 1 101,16 use CONSTRUCTION PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. "Please Print" SITE LOCATION King Co Assessor's Tax No.: 920247-0090 Site Address: 1379 Southcenter Mall Suite Number: Floor: ground Tenant Name: Crispy Town New Tenant: m .....Yes ❑ ..No PROPERTY OWNER Name: Seafood City- Store development group Address: 2883 Surveyor Street City: Pomona State: CA Zip: 91768 CONTACT PERSON — person receiving all project communication Name: Patricia Shelby Address: 5628 Airport Way South, suite 112 City: Seattle State: wA Zip: 98108 Phone: (206) 420-2242 Fax: Email. plshelby@jjwarch.com GENERAL CONTRACTOR INFORMATION Company Name: Address: City: State: Zip: Phone: Fax: Contr Reg No.: Exp Date: Tukwila Business License No.: H:\Applications\Forms-Applications On Line\2011 Applications\Fermit Application Revised - 8-9-11.dom Revised: August 2011 bh ARCHITECT OF RECORD Company Name: JJW Architects and Planners Architect Name: Jeff wasserman Address: 5628 Airport Way South, suite 112 City: Seattle State: WA Zip: 98108 Phone: (206) 420-2242 Fax: Email: jwasserman@jjwarch.com ENGINEER OF RECORD Company Name: Jet Power Engineer Name: Jeff Stauffer Address: 1935 Silverton Road City: Salem State: OR Zip: 97301 Phone: (503) 363-2334 Fax: (506) 363-2622 Email: jeff.s@jetindustries.net LENDER/BOND ISSUED (required for projects $5,000 or greater per RCW 19.27.095) Name: Gr —ro � Address: l City: State: Zip: Page 1 of 4 BUILDING PERMIT INFORMATION—206-431-3670 Valuation of Project (contractor's bid price): $ 65,000 Existing Building Valuation: $ 3,347,100 Describe the scope of work (please provide detailed information): Will there be new rack storage? ❑..... Yes O.. No If yes, a separate permit and plan submittal will be required. Provide All Building Areas in Square Footage Below PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact: Handicap: Will there be a change in use? ❑....... Yes {7]....... No If "yes", explain: FIRE PROTECTION/HAZARDOUS MATERIALS: ®.......Sprinklers ®.......Automatic Fire Alarm ❑ .......None ❑ .......Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑....... Yes ❑....... No If `yes', attach list of materials and storage locations on a separate 8-1/2"x 11 "paper including quantities and Material Safety Data Sheets. SEPTIC SYSTEM ❑ .......On-site Septic System — For on-site septic system, provide 2 copies of a current septic design approved by King County Health Department. H:Wpplications\foms-Applications On Line1201 I ApplicationeWermit Application Revised - 8-9-11.dom Revised: August 2011 Page 2 of 4 bb Existing Interior Remodel Addition to Existing Structure New Type of Construction per IBC Type of Occupancy per IBC V Floor 2,390 2,390 IIB A2 2 Floor 3rd Floor Floors thru Basement Accessory Structure* Attached Garage Detached Garage Attached Carport Detached Carport Covered Deck Uncovered Deck PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact: Handicap: Will there be a change in use? ❑....... Yes {7]....... No If "yes", explain: FIRE PROTECTION/HAZARDOUS MATERIALS: ®.......Sprinklers ®.......Automatic Fire Alarm ❑ .......None ❑ .......Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑....... Yes ❑....... No If `yes', attach list of materials and storage locations on a separate 8-1/2"x 11 "paper including quantities and Material Safety Data Sheets. SEPTIC SYSTEM ❑ .......On-site Septic System — For on-site septic system, provide 2 copies of a current septic design approved by King County Health Department. H:Wpplications\foms-Applications On Line1201 I ApplicationeWermit Application Revised - 8-9-11.dom Revised: August 2011 Page 2 of 4 bb PUBLIC WORKS PERNUT INFOkr4ATION - 206-433-0179 Scope of Work (please provide detailed information): Call before you Dig: 811 Please refer to Public Works Bulletin #1 for fees and estimate sheet. Water District ❑ ...Tukwila ❑... Water District # 125 ❑ .. Highline ❑ .. Renton ❑ ...Water Availability Provided Sewer District ❑ ...Tukwila ❑ ... Valley View ❑ .. Renton ❑ .. Seattle ❑ ...Sewer Use Certificate ❑... Sewer Availability Provided Septic System: ❑ On-site Septic System — For on-site septic system, provide 2 copies of a current septic design approved by King County Health Department. Submitted with Alpylication mark boxes which a I : ..Civil Plans (Maximum Paper Size — 22" x 34") ❑ ...Technical Information Report (Storm Drainage) ❑ .. Geotechnical Report ❑ ...Traffic Impact Analysis ❑ ...Bond ❑ .. insurance ❑ .. Easement(s) ❑ .. Maintenance Agreement(s) ❑ ...Hold Harmless — (SAO) ❑ ...Hold Harmless — (ROW) Proposed Activities (mark boxes that annlv): ❑ ...Right-of-way Use - Nonprofit for less than 72 hours ❑ .. Right-of-way Use - Profit for less than 72 hours ❑ ...Right-of-way Use - No Disturbance ❑ .. Right-of-way Use —Potential Disturbance ❑ ...Construction/Excavation/Fill - Right-of-way ❑ Non Right-of-way ❑ ❑ ...Total Cut cubic yards ❑ ...Total Fill cubic yards ❑ ...Sanitary Side Sewer ❑ ...Cap or Remove Utilities ❑ ...Frontage Improvements ❑ ...Traffic Control ❑ ...Backflow Prevention - Fire Protection Irrigation Domestic Water ❑ .. Work in Flood Zone ❑ .. Storm Drainage ❑ .. Abandon Septic Tank ❑ .. Curb Cut ❑ .. Pavement Cut ❑ .. Looped Fire Line ❑ .. Grease Interceptor ❑ .. Channelization ❑ .. Trench Excavation ❑ .. Utility Undergrounding ❑ ...Permanent Water Meter Size... WO # ❑ ...Temporary Water Meter Size.. WO # []...Water Only Meter Size............ WO # ❑... Deduct Water Meter Size ❑ ...Sewer Main Extension.............Public ❑ Private ❑ ❑ ...Water Main Extension.............Public ❑ Private ❑ FINANCE INFORMATION Fire Line Size at Property Line Number of Public Fire Hydrant(s) ❑ ...Water ❑ ...Sewer ❑ ...Sewage Treatment Monthly Service Billing to: Name: Day Telephone: Mailing Address: City State Zip Water Meter Refund/Billing: Name: Day Telephone: Mailing Address: City State zip H:\Applications\Forms-Applications On Line\2011 ApplicationsTermit Application Revised - 8-9-1l.docx Revised: August 2011 Page 3 of 4 bh PERMIT APPLICATION NOTES — Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING Signature: Dater t� ZAI�O ] Print Name: Patricia Shelby Day Telephone: (206) 420-2242 Mailing Address: 5628 Airport Way South Seattle WA 98108 City State Zip H:1Applications\fortm-Applications On Line12011 ApplicationsTermit Application Revised - 8-9-11.docx Revised: August 2011 Page 4 of 4 bh DESCRIPTIONS PermitTRAK ACCOUNT QUANTITY PAID $1,818.88 D16-0210 Address: 1379 SOUTHCENTER MALL Apn: 9202470010 $1,203.86 DEVELOPMENT $1,146.75 PERMIT FEE R000.322.100.00.00 0.00 $1,142.25 WASHINGTON STATE SURCHARGE B640.237.114 0.00 $4.50 TECHNOLOGY FEE $57.11 TECHNOLOGY FEE R000.322.900.04.00 0.00 $57.11 M16-0124 Address: 1379 SOUTHCENTER MALL Apn: 9202470010 $283.03 MECHANICAL $269.55 PERMIT ISSUANCE BASE FEE R000.322.100.00.00 0.00 $32.50 PERMIT FEE R000.322.100.00.00 0.00 $237.05 TECHNOLOGY FEE $13.48 TECHNOLOGY FEE R000.322.900.04.00 0.00 $13.48 PG16-0108 Address: 1379 SOUTHCENTER MALL Apn: 9202470010 $331.99 GAS $156.88 PERMIT ISSUANCE BASE FEE R000.322.100.00.00 0.00 $32.50 PERMIT FEE R000.322.100.00.00 0.00 $93.00 PLAN CHECK FEE R000.322.103.00.00 0.00 $31.38 PLUMBING $157.44 PERMIT ISSUANCE BASE FEE R000.322.100.00.00 0.00 $32.50 PERMIT FEE R000.322.100.00.00 0.00 $124.94 TECHNOLOGY FEE $17.67 TECHNOLOGY FEE TOTAL1: R000.322.900.04.00 0.00 $17.67 :: Date Paid: Tuesday, February 14, 2017 Paid By: WEST COAST CONSTRUCTION Pay Method: CHECK 35406 Printed: Tuesday, February 14, 2017 1:20 PM 1 of 1 CRSY57EM5 DESCRIPTIONS ermitTRAK • QUANTITY PAID $1,251.60 016-0210 ,Address: 1379 SOUTHCENTER MALL Apn: 9202470010 $742.46 DEVELOPMENT $742.46 PLAN CHECK FEE 8000.345.830.00.00 0,00 $742.46 4 ;. EL16-0696 Address: 1379 SOUTHCENTER MALL Apn: 9202470010 $378.32 ELECTRICAL $360.30 PERMIT FEE MULTI-FAM/COMM R000.322,101,00.00 0.00 $360.30 TECHNOLOGY FEE $18.02 TECHNOLOGY FEE R000.322.900.04.00 .0.00 $18.02 7.': M16-0124 Address: 1379 SOUTHCENTER MALL Apn: 9202470010 $67.39 MECHANICAL $67.39 PLAN CHECK FEE R000,322.102.00.00 0.00 $67.39 � ,PG16-0108 Address: 1379 SOUTHCENTER MALL Apn: 9202470010 $63.43 PLUMBING $63.43 PLAN CHECK FEE R000.322.103.00.00 0.00 $63.43 • , , • ! . 1 Date Paid: Thursday, July 28, 2016 Paid By: JJW ARCHITECTS Pay Method: CHECK 3144 Printed: Thursday, July 28, 2016 9:11 AM 1 of 1 ��g -,7irE`;�°'i�'r'?" SYSTEMS INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Approved per applicable codes. LJ Corrections required prior to approval. pector: 115VL ❑ REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. I" INSPECTION RECORD Retain a copy with permit im 02.7 -- rr�?-y / 'l 6yJt3` INSPECTION NUMBER PERMIT NUMBERS CITY OF TUKWILA FIRE DEPARTMENT 206-575-4407 Project: Type of IInys'-pection: Address: Contact Person: Suite #: Pre -Fire: Special Instructions: Phone No.: AN - 10 Approved per applicable codes. ` Corrections r irld prior to approval. COMMENTS: Sprinklers: x Fire Alarm: Vt- '7> Hood & Duct: n S Monitor: 67 (la,/7-DI /;X� Pre -Fire: Permits: Occupancy Type: t L;6 77-/ - / 4--s S/Yvee r Avow- -- , r •� t� � �/ J ,,f/ ! f �tV //V -S Tq-z Needs Shift Inspection: Sprinklers: x Fire Alarm: Vt- '7> Hood & Duct: n S Monitor: 67 (la,/7-DI /;X� Pre -Fire: Permits: Occupancy Type: I Inspector: � 14 I Date: I H rs.: f I $100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. Bming Aaaress Attn: Company Name: Address: City: State: Zip: Word/Inspection Record Form.Doc 3/14/14 T.F.D. Form F.P. 113 4- INSPECTION RECORM. Retain a copy With permit �1312� l r INSPECTION NUMBER PERMIT NUMBERS CITY OF TUKWILA FIRE DEPARTMENT 206-575-4407 Project: 60 w� Type of Inspection: 4 d 0 Address: Suite #: G Contact Person: Special Instructions: Phone No.: Approved per applicable codes. ` rcorrections _ required prior to approval. COMMENTS: S T' Z-) X40 --va 7- w YL�-��ZoN 5 • ,Needs Shift Inspection: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: Inspector: Date: $100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. tsming Aaaress Attn: I Company Name: Address: City: State: Zip: Word/Inspection Record Form.Doc 3/14/14 T.F.D. Form F.P. 113 INSPECTION RECORD 03-7 I Retain a copy with permit / INSPECTION NUMBER PERMIT NUMBERS CITY OF TUKWILA FIRE DEPARTMENT 206-575-4407 Project:/� �-- ) C��� /p�l Type of Inspection: a v/ / Address: Suite #: Contact Person: Special Instructions: Phone No.: —1N' Approved per applicable codes. Corrections required prior to approval. r COMMENTS: 7e Needs Shift Inspection: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: Inspector:/ Date: Hrs.: $100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. tsming Aaaress Attn: Company Name: Address: City: State: Zip: Word/Inspection Record Form.Doc 3/14/14 T.F.D. Form F.P. 113 z zrosvnc e O6OO'LVZOZ6 =0N 1302Nd B 'vinOg mni 6LEL llbW BLEt u, � � 9 n� �ws'wasg� owr� 2131N30H1t10S IN33H 133HS a3nOO o e 0 m g _ g � 3 � d leg JAM $ E H 6 e$$ a m Z f H m a I. � � - o w� •.., BIIIGIII IIII p LL p� e w Y ca r9ge� k Z ` 1 r I I� U ;�; W �gLL 9= o ` R. d, is t, 111 ° ;q 1 1 1 ZG 6 oa CR �v14. l " 4p�p 3 u a M+ W S83 Wg uF� gi 3g Oz€ 3 ab b I a vsl2 v 3 25 of aL`e y o s A Pk W. J 1 ' G G J O co COD • u„, Famtiv Parking NM(COD O co �` NLLJ O N g L *` a gj� x o • bra• - tiZ Q O O Z 03 y B Z WJ O i — �� i o W Cj_J zii. P Gly aM a � cs• .. ^ Z © ..go- r t J 4 e 1 <4 ° ” Z S-th-M.,Pkwy. -� ip jY m a3 112, H J1 11 lit 4 v ��s iSY6 o 3a �g Medd Z ° �= gi B4 b c, d 8 Ills QQ b yyii jj� WOW I$ .8Y4YYY �XY3 �>B W ll0sg gi ds F it 09 s 8 8L : rt SS i YSea6a4 s 's#aas "a Wt. = �..r:. ' ut.11s lWbs �Ymax oso b1'I3W3JaIfvLa 92M tlm aalm�'"W" TfM H31N30HinOS BCC I w� d NO 8 .�wmwe e+av�rorr - e S3dA1 llb'M aNt/ NH'id ONI11X3 0 4 ` an Lu 8 _ rn�<<t- 4 � I II I I � —— b - - ! I I I 1 44 i I I ZZV I - law LV 3g 6 ! 4 t p ! Ali / I I - - _ $ - - C b (} C ! C Z it W ! f - - - •-- -- - W g it ml.NtwwtOlwm aawwNwnm USE HIM dig;` I b t _. VIE HIM —.Ift sa / dolf s21 8& 1 ---------------- -r -------------- 0 t 3 !—� e a <8> --- - — - r------ -------- ------- - - � 1 - G �--------- -----' H 8i Y O' 1 >f s9 a rq 1 Wei . zo �e ' 4 i i lL g� �Se 1 - 1 YYY € i ARO'ZrA'9SL A woos »�n•.m�+s Ltt 4 9 W,"! MV1 aad�y pps ..AdM R,lffYlY11Y 06WLOZOZ6 :ON 1302Nd 9906 VM bIIMNf1L 11VW U3LN3oH.Lnos em NVId ONIII30 o31331d3a I FAM 9i 3, ys N LL O� 19=;a=a IjI V O Y a e �+A i y• a � y i z Z �9E �gZ E A laL W� 2� Y IIS i 9� S y� 8 9 9 8 5 E a S€^3 ¢C s2 F t a€ 3 CCR a HEpp a3 E �v `bL3X r e le. a f 9i 3, ys N LL O� 19=;a=a IjI V O Y a e �+A i y• a � y i fBSf Z �9E Uy LL A laL W� 2� Y IIS i 9� S y� 8 9 9 8 5 E 9i 3, ys N LL O� fUA a N O Y a o o s Z Z Uy LL A laL W� n 0800-L4ZOZ6 :ON 13O21Vd r � muazs'M:a 99w6vm'YIIM ni aotaa vm• m..s zu ama •vm.s Awn u.M. eras lltlW a31N3OHinoS 6LE L $ NVId Joom s a a O 8 Z 50 CLLL; 8 Ell 0 0 Q i S 2012 Washington State Energy Code Compliance Forms for Commercial, Group R1, and > 3 story R2 and R3 ':Mechanical Summary MECH-SUM' 2012 Washington State Energy Code Com liance Forms for Commercial Buildings including R2 & R3 over 3 stories and all R1 Revised Aug2015 Project Info Project Address: 1391 Southcenter Mail Date 6/24/2016 Tukwila, WA 98188 For Building Dept. Use 1 - This address line will copy onto other forms Applicant Name: 1 - This address line will copy onto other forms Applicant Address: 1 - This address line will copy onto other forms L Applicant Phone: 1 - This address line will copy onto other forms Project Description ❑ New Building [] Building Addition ❑ Tenant Improvement Q System Retrofit ❑ No System Changes Briefly describe mechanical systems in the text box provided Restaurant equipment replacement. Makeup Air (heating only) and Grease Exhaust Fan ❑ Total Bldg Performance RECEIVED Total Bldg Performance compliancep includes all mandatory provisions per CITY OF T U K W I L A C O R RE CT &ON C401.2 Option 2. MECH-SUM, and C407 Energy Analysis Summary forms required. �, ,� 19 20130MECH-CHK, LTR # Mechanical Systems Summary PERMIT CENTER Air Compliance Heating Fan Flow Economizer Ventilation Equip ID Type of System (Note 1) Space(s) Served Path and Cooling Controls (Note 2) (Note 3) Energy Recovery MAU-3 MAKE-UP AIR SYSTEM KITCHEN EXHAUST HOOD Simple single zone system Heating only Variable speed (VS) No cooling, NA Not Required Not Required v C IlanP CRT 91-1 11 Q10N I D4V IJ Note 1 - Provide basic description of system type, for example: unitary rooftop air handler, built-up central air handler, single -packaged, split system or packaged terminal air conditioner or heat pump, unit heater, warm -air furnace, electric resistance heater, 4 -pipe fan coil, VRF system, energy recovery air handler, make-up air system, ground or water -source heat pump, etc. Note 2 - If taking an exception to air economizer, select exception taken from drop down menu and complete MECH-ECONO form. Summary definitions of each exception are listed in MECH-ECONO. Note 3 - If ventilation "Not applicable" is selected, provide explanation in Project Description box above. HVAC Hydronic Systems ❑ Hydronic chilled water ❑ Waterdoop heat pump ❑- No hydronic systems ❑ Hydronic heating El Geothermal Equipment Type (s) ❑ Hot water heating tank(s) ❑ Instantaneous Q No service water systems Service Water Heating Systems ❑ Dedicated boiler ❑ Heat exchange from space heat boiler or central hot water/steam Distribution Type (s) ❑ Circulation System ❑ On -demand [] Mechanical Plans ❑ MECH-EQ Form Mechanical Schedules Indicate location of equipment compliance information. If provided on plans then MECH-EQ forms are not required, however, include on plans all applicable compliance information listed in MECH-EQ tables. ❑ Load calculation summary Q MECH-LOAD-CALC Foran Design Load Calculations Provide design load calculations for all mechanical systems and equipment serving the building heating, cooling or ventilating needs. If a load calculation summary is provided with the permit documents that includes all applicable compliance information then the MECH-LOAD-CALC form is not required. 2012 Washington State Energy Code Compliance Forms for Commercial, Group R1, and > 3 story R2 and R3 Mechanical Summary, •• 2012 Washington State Energy Code Compliance Forms for Commercial Buildings including R2 i£ R3 over 3 stories and all R1 Revised Aug 2015 ❑ Project includes HVAC air distribution systems that provide heating and/or cooling If yes, provide a MECH-FANSYS -SUM form. Fan Power ❑ For one or more systems, the total fan motor nameplate hp of all fans in HVAC system exceeds 5hp. If yes, provide a separate MECH-FANSYS form for each HVAC system exceeding the 5 horsepower threshold. Refer to Section C403.2.10 and MECH-FANSYS-DOC for requirements and exceptions. Commissioning Exception ❑ Commissioning will be provided for all applicable systems Summary Commissioning Exceptions: Describe means of eligibilty for Commissioning exception (capacity, Simple system. No Economizer. Makeup air heating. 84,600 btuh input. n Mechanical system(s) etc) for all systems noted as taking exception in Mechanical Systems Summary table. Refer to Section C408.2 and C408.4 for exceptions. ❑ Service water heating system(s) For systems requiring commissioning, Figure C408.1.2.1 Commissioning Compliance Checklist shall be submitted to the code official upon project completion. Low Energy and Semi -Heated Spaces (Note 6 and 7) Peak Space Heating Cooling Conditioning Space Area Served, Capacity, Btu/h Capacity, Btu/h Capacity, Compliance Type Location in Plan(s) Space(s) Served square feet (Note 4) (Note 5) Btu/h-sf Check Notes Note 4 - Provide total installed heating output capacity of systems serving Low Energy or Semi -Heated space(s) in btuh. Note 5 - Provide total installed cooling capacity of system serving Low Energy space(s) in Btu/h. Not allowed for semi -heated spaces. Enter 0 if no cooling. Note 6 - Refer to Section 0101.5.2 Low Energy Building. Intalied peak space conditioning capacity, heating or cooling, may not exceed 3.4 Btu/h-sf. Note 7 - Refer to Section C402.1.4 and Semi -Heated Space definition in Chapter 2. Total heating output capacity may not exceed 8 btuh/sf. Only systems without electric resistance heating and no cooling are eligible for the wall.. insulation exception under semi -heated. 2012 Washington State Energy Code Compliance Forms for Commercial, Group R1, and > 3 story R2 and R3 2 Washington State Energy Code Compliance Forms for Commercial Buildinas includina R2 & R3 over 3 stories and all Rt RAvieAn Ann gniF Project Address 1391 SouthcenterMail Date 6/24/2016 The following information is necessary to check a permit application for compliance with the mechanicial systems and equipment requirements of the Washington State Energy Code, Commercial Provisions. Applicable Code Section Code Provision Information Required - Must be in q permit documents Location in Building Department (yes,no,na) Documents Notes GENERAL PROVISIONS Equipment Sizing & Performance yes C403.2.1 Load calculations Load calculations performed per ASHRAE Std 183 or equivalent per Chapter 3 yes C403.2.2 Equipment and system Output capacities of heating and cooling equipment and systems do not exceed the next large M0.1 sizing available equipment size above the calculated bads; note exceptions taken no C403.2.5 Minimum ventilation Ventilation (natural or mechanical) provided per IMC; indicate mechanical ventilation is capable of being reduced to minimum requirement per IMC C403.2.3 & 3 C403.2..2 & Equipment minimum Provide equipment schedules or complete MECH-SUM tables with type, capacity, efficiency, M0.1 yes C403.232.1 efficiency test standard (or other eficiency source) for all mechanical equipment Y es C403.2.13 Electric motor efficiency cYp, Provide equipment schedule with h rpm, and efficiency for all motors; note exceptions taken M0.1 no C403.2.10.1 Fan power limitation For all applicable systems > 5hp, provide system total nameplate hp in MECH-FANSYS-SUM form no C403.2.10.1 Fan power limitation For all applicable fan systems > 5hp, verify fan system motor hp or bhp complies with fan powerlimitsper Table C403.2.10.1 1), provide MECH-FANSYS form for each system no C403.2.10.2 IMotor nameplate hp Indicate fan motors specified are the smallest available motor hp size greater than fan bhp, note exceptions taken no C403.2.10.3 & C403.2.13 Fractional h fan motors p Indicate fan motors 1/12 to 1 h are ECM p type or meet minimum efficiency req. no C403.2.3 a ximiu air cooled chiller Indicate air-cooled chiller capacity does not exceed air-cooled chiller limit no C403.2.3.1Non-standard water-cooled Full -load and NPLV values for water-cooled centrifugal chiller adjusted for non-standard chillers operational conditions no C403.2A 2.1. Centrifugal fan cooling Large capacity cooling towers with centrifugal fan(s) meet efficiency requirements for axial fan towers open circuit cooling towers yes C403.2.3 Forced air furnace and unit Indicate intermittent ignition or IID, flue/draft damper & jacket loss M0.1 heaters no C403.2.3.3 Packaged electric Verify all packaged electric equipment that provides > 20,000 Btu/h cooling capacity and heating/cooling equipment heating is a heat pump, note in equipment schedule no C403.2.3.4 Humidification Indicate method of humidification (note requirements for systems with economizer) HVAC System Controls & Criteria no C403.2.4.1 Thermostatic controls Indicate locations of thermostatic control zones on plans, including perimeter systems no C403.2.4.1.1 Heat pump supplementary Indicate staged heating (compression/supplemental) and outdoor lock -out temperature is set heat to 40°F or less no C403.2.4.2 Setpoint overlap (deadband) Indicate 5°F deadband minimum for systems controlling both heating & cooling no C403.2.4.3 Automatic setback and Indicate zone I -stat controls with required automatic setback & manual override shutdown no C403.2.4.3.3 Automatic (optimum) start Indicate system controls that adjust equip start time to match bad conditions C402.4.5.2 & OSA, exhaust, and relief air Indicate location of outdoor air supply intake, and exhaust and relief outlet dampers; verify M0.1 yes C403.2.4.4 dampers Class 1 leakage rating and control type (motorized or gravity); note exceptions taken no C402.4.5.2 Return air dampers Indicate location of return air dampers that are integral to economizer operation; verify motorized control and Class 1 leakage rating; note exception taken no C402.4.5.1 Stairway and shaft vents Indicate location of stairway and shaft vents, verify Class 1 leakage rated motorized dampers and method of activation no C403.2.11 Heating outside a building Indicate radiant heat system and occupancy controls no C403.2.4.5 Snow melt systems Indicate shut-off controls based on outdoor conditions no C403.2.4.6 Combustion heating Indicate modulating or staged control equipment no C403.2.4.7 Group R1 hotel/motel Indicate method for guest room temperature automatic setback (heating) & set-up (cooling), systems confirm adjustment of at least 5°F minimum. no C403.2.4.8 / E Group R2/R3 dwelling and Indicate 5-2 programmable thermostats in primary spaces with minimum of two setback sleeping unit systems periods and 10"F deadband; note exceptions taken no C403.2.5.1 Demand controlled ventilation Indicate high -occupancy spaces and systems requiring DCV no C403.2.5.2 Occupancy sensors Indicate spaces requiring occupancy -based system control and method; or alternate means rovided to automatically reduce OSA when partially occupied 2012 Washington State Energy Code Compliance Forms for Commercial, Group R1, and > 3 story R2 and R3 PermitMechanical Page 2 of , 2012 Washington State Energy Code Compliance Forms for Commercial Buildings including R2 & R3 over 3 stories and all R1 Revised Aug 2015 Project Address 1391 Southcenter Mail JDate 6/24/2016 The following information is necessary to check a permit application for compliance with the mechanicial systems and equipment requirements of the Washington State Energy Code, Commercial Provisions. Applicable Code Section Code Provision Information Required - Must be in permit documents Location in Building Department (yes,no,na) Documents Notes GENERAL PROVISIONS, CONTINUED HVAC System Controls & Criteria, Continued na C403.2.5.3 Enclosed loading dock/parking garage Indicate enclosed loadingdock and enclosed parking P 9 garage ventilation system activation and ventilation control method yes C403.2.5.4.1 Kitchen exhaust hoods Indicate kitchen hoods requiring make-up air, indicate make-up air source and conditioning M0.1 method na C403.2.5.4.2 Laboratory exhaust systems Indicate lab exhaust systems requiring heat recovery, method & efficiency; or altemative method taken (VAV, semi -conditioned makeup, or CERM calculation) na C403.2.6.1 Energy recovery (ER) - ventilation systems Indicate ventilation systems requiring ER, method & efficiency; note exceptions na C403.2.6.2 Energy recovery (ER) - condensate systems Indicate on-site steam heating systems requiring energyrecovery na C403.2.6.3 Energy recovery - coolerlfreezer condensers Indicate remote refrig. condensers requiring ER and use of captured energy na C403.4.6 Energy recovery (ER) - Indicate condenser systems requiring ER to pre -heat service water, indicate ER effectiveness; condenser systems note exceptions taken na 0403.2,12 Variable flow control - Indicate fan and pump motors x7.5 hp and the method of variable flow control (VSD or fansipumps equivalent controls) na C403.2.12.1 Variable flow control - heat Indicate heat rejection equipment and cooling tower fans requiring variable flow control and rejection equipment method Indicate single zone fan systems requiring airflow reduction capability in response to reduced na C403.2.12.2 Large volume fan systems cooling or heating demand in a zone, or adjacent zones without separating walls, with > 10,000 CFM supply air, note exceptions taken na C403.2.12.2 Single zone AC systems Indicate method of cooling demand -based fan control for air conditioning systems > 110,000 Btu/h serving single zones na C403.2.4.10 DDC system capabilities Identity all DDC system input/output control points and indicate capability for trending and demand response set oint adjustment Ducting Systems 0403.2.7.1 & Dud construction Indicate all ductwork constructed and sealed per IMC, C402.4 leakage requirements and IBC na C403.2.7.3 vapor retarder requirements yes 403.2.7.3.1_ Dud pressure Identify location of low, medium and high pressure ductwork on plans classificationsM2.1 na C403.2.7.3.3 High pressure duct leakage Indicate high pressure dud leakage testing requirements on plans; provide test results to test jurisdiction when completed yes 403.2.7.1 /1 Duct insulation Indicate R -value of insulation on ductwork M0.1 Piping Systems na C403.2.8 Piping insulation Indicate R -value of insulation on piping na C403.2.8.1 Pcpmg insulation exposed to weather Indicate method of protection from damage/degredation SIMPLE SYSTEMS Qualifying Systems yes C403.3 Qualifying single zone Verify unitary or packaged equipment does not exceed capacity limits, does not have active systems humid fcabon or simultaneous heating/cooling M0.1 na C403.3 Qualifying 2 -pipe heating systems Verify 2 -pipe heating -only system does not exceed capacity limits na C403.3.2 Hydronic system controls Refer to Complex Systems Section 0403.4.3 Simple System Economizers na C403.3.1 Air economizer required Indicate cooling systems requiring economizer controls; note in equipment schedule na C403.3.1 Air economizer exceptions Indicate eligible exception(s) taken and provisions to comply with exception(s) na C403.3.1.1.1 Air economizer capacity Indicate modulating OSA control capability up to 100% OSA; note exceptions taken na C403.3.1.1.2 Integrated air economizer Indicate capability for partial air economizer operation for systems with capacity > 65,000 Btu/h operation na C403.3.1.1.3 Air economizer high limit controls Indicate high limit shut-off control method per Table C403.3.1.1.3(2) 2012 Washington State Energy Code Compliance Forms for Commercial, Group R1, and > 3 story R2 and R3 PermitMechanical Plans ..g- 3 of 2012 Washington State Energy Code Compliance Forms for Commercial Buildings including R2 & R3 over 3 stories and all R1 Revised Aug 2015 Project Address 1391 SouthcenterMait Date 6/24/2016 The following information is necessary to check a permit application for compliance with the mechanicial systems and equipment requirements of the Washington State Energy Code, Commercial Provisions. Applicable Code Section Code Provision Information Required - Must be in eq permit documents Location in Building Department (yes,no,na) Documents Notes COMPLEX SYSTEMS Complex System Economizers na C403.4.1 Air economizer required Indicate cooling systems requiring economizer controls; note in equipment schedule na C403.4.1 Air economizer exceptions Indicate eligible exception(s) taken and provisions to comply with exception(s) na C403.4.1.1 Water economizer capacity For eligible systems where water economizer may be provided in lieu of air economizer, indicate system is capable of 100% cooling capacity at 50°F db/45°F wb OSA na C403.4.1.2 Water economizer Indicate precooiing coils and heat exchangers in water economizer system do not exceed maximum pressure drop pressure drop limit na C403.4.1.3 Integrated economizer operation Indicate capability for partial economizer operation for air or water economizer systems na C403.4.1.4Economizer heating system Verify control method of HVAC systems with economizers does not increase building heating impact energy usage during normal operation Specific System Requirements na C403.4.2 & C403.2.12 VAV fan control Indicate fans requiring variable flow control and method na C403.4.2.1 VAV fan static pressure Indicate sensor locations on plans; include at least one sensor per major duct branch sensors na C403.4.2.2 VAV fan static pressure setpoint Indicate fan system static pressure setpoint based on zone requiring most pressure na C403.4.5VAV systems serving Indicate supply air systems serving multiple zones, method of primary air control, and zones multiple zones served; Indicate VAV or note exceptions taken na C403.4.5 VAV systems serving For each air system terminal, indicate the maximum air flow rate of primary supply air during muftiple zones zone peak cooling and the maximum airflow, rates during zone peak heating. na C403.4.5.4 VAV system supply air reset Indicate controls that automatically reset supply air temp in response to loads na C403.4 Large capacity cooling Indicate method of multi -stage or variable control for building cooling system capacity > 300 systems tons na C403.4.7 Hot gas bypass limitation Indicate cooling equipment unloading or capacity modulation method na C403.4.3 Large capacity boiler systems Indicate multi -stage or modulating burner for single boilers > 500,000 Btu/h na C403.4.3 Boiler sequencing Indicate automatic controls that sequence operation of multiple boilers na C403.4.3.5 Chiller / boiler plant pump Indicate capability to automatically reduce overall plant flow and shut-off flow through chillers & isolation boilers when not in use C403.4.3.6 & Variable flow control - na C403.2.12 pumps Indicate pumps requiring variable flow control & method na C403.2.12.1 & C403.4.4 Variable flow control - cooling towers Indicate cooling tower fans requiring variable flow control and method na C403.4.3.4 Hydronic system part load Indicate heating & chilled water systems have the capability to automatically reset supply water controls temp AND reduce flow by s 50% for systems > 300,000 Btulh na C403.4.3.2 Two -pipe changeover systems Indicate deadband, heating/cooling mode scheduling and changeover temperature range na C403.4.3.3.1 Water loop heat pump - Indicate capability of central equipment to provide min. 20°F water supply temp deadband deadband between heat rejection and heat addition modes na C403.4.3.3.2.1 Water loop heat pump - Indicate method used to limit system heat loss when heat rejections is not needed heat rejection, Zone 4 na C403.4.3.3.2.2 Water loop heat pump - Provide heat exchanger that separates cooling tower and heat pump loop heat rejection, Zone 5 C403.4.3.3.3 Water loop heat pump - Indicate 2 -way isolation valve on each heat pump and variable flow control for systems with na isolation total pump power> 10 hp na C403.5 Walk-in cooler/ freezer- anti -sweat heaters Indicate w/sf & control method for walk-in cooler/freezer door anti -sweat heaters na C403.5 / 6 Cooler / freezer - evaporator Indicate motor type for evaporator and condenser fans < 1 hp and condenser fans 2012 Washington State Energy Code Compliance Forms for Commercial, Group R1, and > 3 story R2 and R3 PermitMechanical Plans r 2012 Washington State Energy Code Compliance Forms for Commercial Buildings including R2 & R3 over 3 stories and all R1 Revised Aug 2015 Project Address 1391 SouthcenterMail I Date 6/24/2016 The following information is necessary to check a permit application for compliance with the mechanicial systems and equipment requirements of the Washington State Energy Code, Commercial Provisions. Applicable Code Sectio Code Provision information Required - Must be in permit documents Location in Building Department (Yes,no,na ) Documents Notes SERVICE WATER HEATING Service Water Systems C404.2 Water -heating equip min. Provide equipment schedule with type, capacity, efficiency, test standard or other efficiency no efficiency source no C404.3 Temperature controls Indicate temperature controls have required setpoint capability no C404.4 Heat traps Indicate piping connected to equipment have heat traps on supply & discharge no C404.5 Insulation underwater Indicate R-10 insulation under electric water heater tanks heater no C404.6 Service water piping insulation Indicate R -value of insulation on piping; note exceptions taken no C404.7 / 8 Circulation systems and heat trace shut-off Indicate shutoff capability based on occupancy and periods of limited demand no C404.9 Group R-2 service hot water Indicate method of usage metering for dwelling units served by a central service hot water meters system Pools & In -Ground Permanently Installed Spas C404.10.1 Pool heating equip min. Provide equipment schedule with type, capacity, efficiency, test standard or other efficiency no efficiency source no C404.10.1 12 Pool heater on / off controls Indicate automatic on/off control based on scheduling & accessible on/off switch on heater that operates independent of thermostat setting; note exceptions taken no C404.10.3 Pool covers Indicate vapor retardant cover and insulation rating as required no C404.10.3 Pool assembly insulation Indicate rating of Insulation on sides and bottom of pools heated to > 90°F no C404.10.4 Heat recovery Indicate method, exhaust air temperature reduction and recovered energy use; note exceptions taken COMMISSIONING Specific System Requirements no C408.2 Mechanical systems Indicate all mechanical systems to be commissioned; for those that will not be commissioned, commissioning note exception taken no C408.4 Service water heating Indicate all service water heating systems to be commissioned; for those that will not be systems commissioning commissioned, note exception taken no C408.1.1 Commissioning plan Provide commissioning plan for all systems requiring commissioning; include in plan all required items per this section C408.2.2.1 & Air system and hydronic Include in commissioning plan that air and hydronic systems shall be balanced in a manner to no C408.2.2.2 system balancing first minimize throttling losses, then adjust to meet design flow conditions no C408.2.2.1 Air system balancing Indicate devices that provide the capability to balance all supply air outlets, zone terminals and devices equipment requiring system balancing no C408.2.2.2 Hydronic system balancing Indicate devices that provide the capability to isolate, balance and measure flow for all devices hydronic equipment requiring system balancing no C408.2.3 Mechanical systems functional performance Provide description of functional performance testing procedures for all applicable systems testing Including:equipment, controls, economizers no C408.4.1 Service water heating functional performance Provide description of functional performance testing procedures for all applicable systems testing including: equipment, controls, pools and spas no C408.1.4 Systems operation training Indicate required systems operation training measures to be provided no C408.1.2 & Documentation Indicate required documentation including: record documents, manuals, balancing reports, C403.1.3 commissioning preliminary and final reports no C408.1.2.1 Acceptance report Indicate that Commissioning Compliance Checklist (Figure C408.1.2.1) is required upon com letion of Ereliminary commissioning report If 2012 Washington State Energy Code Compliance Forms for Commercial, Group R1, and > 3 story R2 and R3 Mechanical Fan System Power Allowance 2012 Washinaton State Enerav Code Comnliance Forms fnr Cnmmerrial Ri ildinns in(gwlinn 59 R RR nvar 3 cfnriwa and all R1 Rov earl AI, n Dn1 a Project Info Project Address: 1391 Southcenter Mall Date 6/24/2016 Tukwila, WA 98188 For Building Dept. Use Fill this line out on MECHSUM Applicant Name: Fill this line out on MECHSUM Applicant Address: Fill this line out on MECHSUM Applicant Phone: Fill this line out on MECHSUM HVAC Air Distribution System Schedule List all HVAC systems that have the capability to provide heating and/or cooling to the spaces they serve. Fan System ID Speed Control (Note 1) Description System Total Nameplate HP (Note 2) Fan Power Calculation (Note 3) MUA-31 EF -3 VAV TYPE4 MAKEUP AND EXHAUST 2.25 < 5 hp Note 1 - Constant Volume (CV), Variable Air Volume (VAV), or HospitallLab CV system that qualifies for VAV budget per C403.2.10.1 Exception 1. Single zone VAV systems shall comply as CV. Note 2 - Enter the total nameplate hp of all fans associated with the delivery and removal of conditioned air by the system. Include all supply, return/relief, exhaust and exhaust hoods (>1 hp), make-up air, dedicated outside air (DOAS), booster fans, and series fan powered terminals. VA V parallel fan -powered terminals and economizer relief fans do not need to be included if the fans do not operate at peak conditions. Note 3 - Indicate if MECH-FANSYS form is required (Yes), or the system is not required to provide this information because it has a combined total nameplate motor hp less than 5 hp (< 5 hp) or the system is ventilation only and thus has no heating or cooling capacity (No). MECH-FANSYS Forms A MECH-FANSYS form shall be provided for each system with total nameplate hp greater than 5 hp. Select (Add Fan System Form) to generate an additional form. Added forms can be deleted with button in cell E38 of the added 2012 Washington State Energy Code Compliance Forms for Commercial, Group R1. and > 3 story R2 and R3 ,Design• . • Calculation Summary MECH-LOAD-CALC 2012 Washington State Energy Code Com liance Forms for Commercial Buildings including R2 & R3 over 3 stories and all R1 Revised Aug2015 Project Info The following information shall be included in the load calculation program summary submitted with the permit documents. If a load calculation summary is not available, provide the required information below. Project Address: 1391 Southcentar Mall Date 6/24/2016 Tukwila, WA 98188 For Building Dept. Use Fill this line out on MECH-SUM Applicant Name: Fill this line out on MECH-SUM Applicant Address: Fill this line out on MECHSUM Applicant Phone: Fill this line out on MECH-SUM Equip. ID Area(s) Served Heating Design Cooling Design Load - Bluth (Note Load - Btulh (Note Calculation Method 1) 1) (Note 2) Notes MAU-1 TYPE -1 HOOD 77,865 1.1 X CFM X DELTA -T 65F TEMP RISE Note 1- Design load shall account for the building envelope, lighting, ventilation and occupancy loads of the space(s) served by the mechanical system. Heating and cooling loads shall be adjusted to account for load reduction achieved by an energy recovery system, if applicable. Note 2 - Computer load calculation program, worksheet (identify source), or equivalent computation procedure in accordance with ASHRAE Standard 183. City of Tukwila Allan Ekberg, Mayor Department of Community Development Jack Pace, Director 8/31/2017 PATRICIA SHELBY 5628 AIRPORT WAY S, STE 112 SEATTLE, WA 98108 RE: Permit No. D16-0210 CRISPY TOWN 1379 SOUTHCENTER MALL Dear Permit Holder: In reviewing our current records, the above noted permit has not received a final inspection by the City of Tukwila Building Division. Per the International Building Code, International Mechanical Code, Uniform Plumbing Code and/or the National Electric Code, every permit issued by the Building Division under the provisions of these codes shall expire by limitation and become null and void if the building or work authorized by such permit has not begun within 180 days from the issuance date of such permit, or if the building or work authorized by such permit is suspended or abandoned at any time after the work has begun for a period of 180 days. Your permit will expire on 10/3/2017. Based on the above, you are hereby advised to: 1) Call the City of Tukwila Inspection Request Line at 206-438-9350 to schedule for the next or final inspection. Each inspection creates a new 180 day period, provided the inspection shows progress. -or- 2) Submit a written request for permit extension to the Permit Center at least seven(7) days before it is due to expire. Address your extension request to the Building Official and state your reason(s) for the need to extend your permit. The Building Code does allow the Building Official to approve one extension of up to 180 days. If it is determined that your extension request is granted, you will be notified by mail. In the event you do not call for an inspection and/or receive an extension prior to 10/3/2017, your permit will become null and void and any further work on the project will require a new permit and associated fees. Thank you for your cooperation in this matter. Sincerely, Bill Rambo J�1 Permit Technician File No: D16-0210 6300 Southcenter Boulevard Suite #100 9 Tukwila, Washington 98188 • Phone 206-431-3670 • Fax 206-431-3665 ON of Tukwila Department of Community Development - Jack Pace, Director January 30, 2017 Lisa Moseley 6670 Central Ave, Ste B Riverside, CA 92504 RE: Request for Application Extension #1 Permit Numbers - D16-0210, EL16-0696, M16-0124, PG16-0108 Dear Ms. Moseley, Allan Ekberg, Mayor This letter is in response to your written request for an extension to Application Numbers D 16-0210, EL16-0696, M16-0124, PG16-0108. The Building Official, Jerry Hight, has reviewed your letters and considered your request to extend the above referenced permits. It has been determined that the City of Tukwila Building Division will be granting an extension to the permits through July 28, 2017. If you should have any questions, please contact our office at (206) 431-3670. Sincerely, l Rachelle Ripley 1 Permit Technician File: Permit No. D16-0210, ELI 6-0696, M16-0124, PG16-0108 Tukwila City Hall - 6200 Southcenter Boulevard - Tukwila, WA 98188 - 206-433-1800 - Website: TukwilaWA.gov n. Rachelle Ripley From: Lisa Moseley <LMoseley@westcoastgc.com> Sent: Wednesday, January 25, 2017 4:17 PM To: Rachelle Ripley Subject: Request for Extension for Permit Applications D16-0210, EL16-0696, M16-0124 Hello Rachelle, Regarding Permit Application PC 16-0108, West Coast Construction is the General Contractor for the Crispy Town 1379 Southcenter Mall Tukwila WA, project. According to City of Tukwila permit applications -D16-0210, EL16-0696, M16-0124 are currently set to expire 1/28/17. West Coast Construction respectfully requests to be granted an extension for Permit Applications D16-0210, EL16-0696, M16-0124, as Tom Witek is the person whom will be traveling to WA to pay the balance due and pick up the permit is still recovering from shoulder surgery, he is scheduled to return to work next week. Please be so kind to respond. Thank you and have a nice day. Request for Extension # I Lisa Moseley Current Expiration Date: >� Project Engineer Extension Request: WEST COAST CONSTRUCTION . CYJ Approved for i d days 6670 Central Ave Ste B Riverside CA 92504 ❑ Denied (provide explanation) P 1951.774.0677 F 1951.351.7783 I E I LMoseley@westcoastgc.com Signature/Initials From: Lisa Moseley [ma iIto: LMoseley@westcoastgc.com] Sent: Tuesday, January 24, 2017 4:54 PM To: Rachelle Ripley (rachelle.ripley@tukwilawa.gov) <rachelle.ripley@tukwilawa.gov> Subject: Request for Extension for Permit Application PG 16-0108 / City of Tukwila Letter 12/1/16 attached Hello Rachelle, Regarding Permit Application PC 16-0108, West Coast Construction is the General Contractor for the Crispy Town 1379 Southcenter Mall Tukwila WA, project. According to the attached City of Tukwila letter dated 12/1/16 the application is currently set to expire 1/28/17. West Coast Construction respectfully requests to be granted an extension for Permit Application PG 16-0108, as Tom Witek is the person whom will be traveling to WA to pay the balance due and pick up the permit is still recovering from shoulder surgery, he is scheduled to return to work next week. Please be so kind to respond. Thank you and have a nice day. 12/1/2016 City of Tukwila Allan Ekberg, Mayor Department of Community Development Jack Pace, Director PATRICIA SHELBY 5628 AIRPORT WAY S, STE 112 SEATTLE, WA 98108 RE: Permit Application No. D16-0210 CRISPY TOWN 1379 SOUTHCENTER MALL Dear PATRICIA SHELBY, In reviewing our current application files, it appears that your permit applied for on 7/28/2016, has not been issued by the City of Tukwila Permit Center. Per the International Building Code, International Mechanical Code, Uniform Plumbing Code and/or National Electrical Code every permit application not issued within 180 days from the date of application shall expire and become null and void. Currently your application has a status of APPROVED and is due to expire on 1/28/2017. If you still plan to pursue your project, you are hereby advised to do one of the following: 1) If the plan review is complete for the project and your application is approved, you may pick up the application before the date of expiration. At the time of permit issuance the expiration date will automatically be extended 180 days. -or- 2) If the plan review is not completed submit a written request for application extension (7) seven days in advance of the expiration date. Address your extension request to the Building Official and state your reason(s) for the need to extend your application. The Building Code does allow the Building Official to approve one extension of up to 90 days. If it is determined that your extension request is granted, you will be notified by mail. In the event that we do not receive your written request for extension or request is denied, your permit application will expire and your project will require a new permit application, plans and specifications, and associated fees. Thank you for your cooperation in this matter. Sincerely, achelle Ripley Permit Technician File No: D16-0210 6300 Southcenter Boulevard Suite #100 o Tukwila Washington 98188 o Phone 206-431-3670 • Fax 206-431-3665 ity of Tukwila Department of Community Development August 10, 2016 PATRICIA SHELBY 5628 A I RPORT W A Y S, STE 112 SEATTLE. WA 981 08 RE: Correction Letter # I DEVELOPMENT Permit Application N umber D16-0210 CRISPY TOWN - 1379 SOUTH CENTER MALL Dear PATRICIA SHELBY, Allan Ekberg, Mayor Jack Pace, Director RECEIVED CITY OF TUKWILA AUS' 19 2016 PERMIT CENTER n©RRECT�N LTR# _1.....� This letter is to inform you of corrections that must be addressed before your development permit can be approved . All correction requests from each department must be addressed at the same time and reflected on your drawings. I have enclosed comments from the following departments: BUILDING DEPARTMENT: Allen Johannessen at 206-433-7163 if you have questions regarding these comments. (GENERAL NOTE) PLAN SUBMITTALS: (Min. size II x 17 to maximum size of 2406; all sheets shall be the same size. New revised plan sheets shall be the same size sheets as those previously submitted) (If applicable) "STAMP AND SIGNATURES" "Every page of a plan set must contain the seal/stamp, signatu re of the licensee(s) who prepared or who had direct supervision over the preparation of the work, and date of signature. Specifications that are prepared by or under the direct supervision of a licensee shall contain the seal/stamp, signature of the licensee and the date of signature. If the "specifications" prepared by a licensee are a portion of a bound specificat ion document that contains specifications other than that of an engineering or land surveying nature, the licensee need only seal/stamp that portion or portions of the documents for which the licensee is responsible." It shall not be required to have each page of "specifications" (calculations) to be stamped and signed; Front page only will be sufficient. (WAC 196-23-010 & 196-23-020) (BUILDING REVIEW NOTES) I. As of July 1 2016 City of Tukwilaadopted the 2015 International Building codes. Please revise all code note references and if applicable details and note to reference current codes. See revised 24" x 36" sheet G- 0.1 Cover Sheet, revision 1,dated 08.17.16, Code Information section , right hand side of sheet. 2. Provide a life safety plan that identifies means of egress. Dimension egress paths. Identify the specific common paths of egress that shall be provided with emergency illumination. Emergency illumination shall have at least an average 1 foot -sand le and a minimum at any point of 0.1 foot candle measured along the path of egress at the floor levelmergency lighting shall also be required for exit discharge doorways. Egress paths shall be continuous to each exit. Designed egress paths shall be those inspected for egress illumination requirements. (IBC Section 107.2.3, 1006 & 1008.1.6 See revised 24" x 36" sheets G- 0.2 Exiting Plan (Path of egress is dimensioned and highlighted with revision bubbles) and A- 3.1 Reflected Ceding Plan (Exit lights and devises are highlighted with revision bubbles), revision 1,dated 08.17.16. 3. Provide a completed 2015 Washington State Nonresidential Energy Code lighting budget compliance form. 2012 NREC Compliance Forms for Lighting is available online at: http://www.neec.net/energy-codes, (scroll down to center of page). 2012 Washington State Energy Code Form for Commercial, Group R1, and > 3 story R2 and R3 attached. 4. FYI: lew HVAC systems or related alterations shall be under a separate Mechanical Permit. Current mechanical perm it M 16-0124 for the Type 1 hood shall be separate. Note: This permit plan review may not be complete as revised plans may require further corrections. Please address the comments above in an itemized forma t with applicable revised plans, specifications, and/or other documentation. The City requires that two (2) sets of revised plan pages, specifications and/or other documentation be resubmitted with the appropriate revision block. In order to better expedite your resubmittal , a'Revision Submittal Sheet' must accompany every resubmittal. I have enclosed one for your convenience. Corrections/revisions must be made in person and will not be accepted through the mail or by a messenger service. If you have any questions, T can be reached at 206-431-3672. Q 4t/ Brenda Holt Permit Coordinator File No 016-0210 k City of Tukwila Allan Ekberg, Mayor Department of Community Development Jack Pace, Director August 10, 2016 PATRICIA SHELBY 5628 AIRPORT WAY S, STE 112 SEATTLE, WA 98108 RE: Correction Letter # 1 DEVELOPMENT Permit Application Number D16-0210 CRISPY TOWN - 1379 SOUTHCENTER MALL Dear PATRICIA SHELBY, This letter is to inform you of corrections that must be addressed before your development permit can be approved. All correction requests from each department must be addressed at the same time and reflected on your drawings. I have enclosed comments from the following departments: BUILDING DEPARTMENT: Allen Johannessen at 206-433-7163 if you have questions regarding these comments. • (GENERAL NOTE) PLAN SUBMITTALS: (Min. size 11x17 to maximum size of 24x36; all sheets shall be the same size. New revised plan sheets shall be the same size sheets as those previously submitted.) (If applicable) "STAMP AND SIGNATURES" "Every page of a plan set must contain the seal/stamp, signature of the licensee(s) who prepared or who had direct supervision over the preparation of the work, and date of signature. Specifications that are prepared by or under the direct supervision of a licensee shall contain the seal/stamp, signature of the licensee and the date of signature. If the "specifications" prepared by a .licensee are a portion of a bound specification document that contains specifications other than that of an engineering or land surveying nature, the licensee need only seal/stamp that portion or portions of the documents for which the licensee is responsible." It shall not be required to have each page of "specifications" (calculations) to be stamped and signed; Front page only will be sufficient. (WAC 196-23-010 & 196-23-020) (BUILDING REVIEW NOTES) 1. As of July 1 2016 City of Tukwila adopted the 2015 International Building codes. Please revise all code note references and if applicable details and note to reference current codes. 2. Provide a life safety plan that identifies means of egress. Dimension egress paths. Identify the specific common paths of egress that shall be provided with emergency illumination. Emergency illumination shall have at least an average I foot-candle and a minimum at any point of 0.1 foot candle measured along the path of egress at the floor level. Emergency lighting shall also be required for exit discharge doorways. Egress paths shall be continuous to each exit. Designed egress paths shall be those inspected for egress illumination requirements. (IBC Section 107.2.3, 1006 & 1008.1.6) 3. Provide a completed 2015 Washington State Nonresidential Energy Code lighting budget compliance form. 2012 NREC Compliance Forms for Lighting is available online at: http://www.neec.net/energy-codes, (scroll down to center of page). 4. FYI: New HVAC systems or related alterations shall be under a separate Mechanical Permit. Current mechanical permit M16-0124 for the Type I hood shall be separate. Note: This permit plan review may not be complete as revised plans may require further corrections. 6300 Southcenter Boulevard Suite #100 • Tukwila Washington 98188 9 Phone 206-431-3670 • Fax 206-431-3665 .fw Please address the comments above in an itemized format with applicable revised plans, specifications, and/or other documentation. The City requires that two 2 sets of revised plan pages, specifications and/or other documentation be resubmitted with the appropriate revision block. In order to better expedite your resubmittal, a 'Revision Submittal Sheet' must accompany every resubmittal. I have enclosed one for your convenience. Corrections/revisions must be made in person and will not be accepted through the mail or by a messenger service. If you have any questions, I can be reached at 206-431-3672. Sincerely, sw--- Brenda Holt Permit Coordinator File No. D16-0210 6300 Southcenter Boulevard Suite #100 o Tukwila Washington 98188 • Phone 206-431-3670 e Fax 206-431-3665 ARN11T COORD COPY PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: D16-0210 PROJECT NAME: CRISPY TOWN DATE: 08/22/16 1 SITE ADDRESS: 1379 SOUTHCENER MALL Original Plan Submittal Revision #_ before Permit Issued X Response to Correction Letter # 1 I Revision # , after Permit Issued DEPARTMENTS: �1 '�' '�� Buil mg Division Fire Prevention ❑ Planning Division ❑ Public Works ❑ Structural ❑ Permit Coordinator ❑ PRELIMINARY REVIEW: DATE: 08/23/16 Not Applicable ❑ Structural Review Required ❑ (no approval/review required) REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: DUE DATE: 09/20/16 Approved ❑ Approved with Conditions 1� Corrections Required ❑ (corrections entered in Reviews) Notation: Denied ❑ (ie: Zoning Issues) REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: 12/18/2013 PERMIT CORD COPY PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: D16-0210 DATE: 08/02/16 PROJECT NAME: CRISPY TOWN SITE ADDRESS: 1379 SOUTHCENTER MALL X Original Plan Submittal Revision # before Permit Issued Response to Correction Letter # Revision # after Permit Issued DEPARTMENTS: A' caw 0• - b Bui ding Division 10 CJS Af Public Works PRELIMINARY REVIEW: Not Applicable ❑ (no approval/review required) REVIEWER'S INITIALS: AA A01/ Fire Prevention Structural ❑ Planning Division Permit Coordinator ❑ DATE: 08/04/16 Structural Review Required DATE: APPROVALS OR CORRECTIONS: DUE DATE: 09/01/16 Approved ❑ Corrections Required (corrections entered in Reviews) Notation: REVIEWER'S INITIALS: Approved with Conditions ❑ Denied ❑ (ie: Zoning Issues) DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg FV Fire ❑ Ping ❑ PW ❑ Staff Initials: l�y�J► LE 12/18/201:+ City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Web site: http://www.Tukwi]aWA.gov REVISION SUBMITTAL Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fax, etc. Date: Ib AuAu51- 245 1 Le Plan Check/Permit Number: D16-0210 ❑ Response to Incomplete Letter # ® Response to Correction Letter # 1 F1Revision # after Permit is Issued RECEIVED CITY OF TUKWILA ❑ Revision requested by a City Building Inspector or Plans Examiner ❑ Deferred Submittal # AUG s 2o1s Project Name: CRISPY TOWN PERMIT CENTER Project Address: 1379 SOUTHCENTER MALL Contact Person: PATRICIA SHELBY Phone Number: Summary of Revision: Jeet)45 d1 Reyowe- le -&i Pffedled MZ %3hl�JoR ;M%k gnegq Cornpll4n ce toon Sheet Number(s): C1' D. / , &-0.2- , /.L .. "Cloud" or highlight all areas of revision including /date of Received at the City of Tukwila Permit Center by: Entered in TRAKiT on WAllermit Center\Templates\forms\Revision Submittal Porm.doc Revised: August 2015 WEST COAST CONSTRUCTION Home Espanol Contact Safety & Health Claims & Insurance Washington State Department of Labor & Industries WEST COAST CONSTRUCTION Owner or tradesperson PERRY, ROBERT SHAUN Principals PERRY, ROBERT SHAUN, PRESIDENT PING, ERIN ASHLEY, SECRETARY PERRY, BRITTANY NICOLE, TREASURER WA UBI No. 604 048 191 Parent company PERRY COAST CONSTRUCTION INC License 3400 CAPITOL BLVD STE 101 OLYMPIA, WA 98501 951-774-0677 THURSTON County Business type Corporation Page 1 of 2 Search L&I A-1. Index help MyLLM Workplace Rights Trades & Licensing Verify the contractor's active registration / license / certification (depending on trade) and any past violations. Construction Contractor Active. ....................._........._................................... Meets current requirements. License specialties GENERAL $1,000,000.00 License no. WESTCCC848Q1 Effective — expiration Effective date 11/30/2016-11/30/2018 05/14/2016 Bond ................. Expiration date American Contractors Indem CO $12,000.00 Bond account no. 100332358 Received by L&I Effective date 11/30/2016 11/29/2016 Expiration date Until Canceled Insurance Mt Hawley Ins Co $1,000,000.00 Policy no. MGLO183758 Received by L&I Effective date 11/22/2016 05/14/2016 Expiration date 05/14/2017 Savings No savings accounts during the previous 6 year period. Lawsuits against the bond or savings .................. No lawsuits against the bond or savings accounts during the previous 6 year period. L&I Tax debts Help us improve ................ _...................... https:Hsecure.Ini.wa.gov/verify/Detail.aspx?UBI=604048191&LIC=WESTCCC848QI&SAW= 2/14/2017 WEST COAST CONSTRUCTION No L81 tax debts are recorded for this contr license during the previous 6 year period, but some may be recorded by other agencies. License Violations ..................................................... No license violations during the previous 6 year period. Workers' comp No active workers' comp accounts during the previous 6 year period. Workplace safety and health Check for any past safety and health violations found on jobsites this business was responsible for. @ Washington State Dept. of Labor & Industries. Use of this site is subject to the laws of the state of Washington. Page 2 of 2 Help us improve https:Hsecure.Ini.wa.gov/verify/Detail.aspx?UBI=604048191&LIC=WESTCCC848Q1&SAW= 2/14/2017 CAVITY STUD BRACING BACK TO STRUCTURE EXTEND DRYWALL TO BOTTOM OF ROOF DECK STORAGE ROOM GYP. BOARD - STORAGE ROOM SIDE METAL STUDS WALL FINISH AS SCHEDULED NEW BASE AS SCHEDULED OPROVIDE AND INSTALL: -NEW 5/8" THICK TYPE'X' GYP BD ON 6" MTL. STUD - PANELS TAPED AND MUDDED FOR LEVEL 4 FINISH AND PAINTED PER SCHEDULE. -NEW BASE AS SCHEDULED WALL TYPES SCALE: 1/2" = V-0" EXTEND EVERY FOURTH STUD TO STRUCTURE EXTEND GYP. BOARD 6" ABOVE GYP BD C° CEILING 0 DRYWALL CEILING - WHERE OCCURS LAY -IN ACOUSTIC 2x4 CEILING TILE WHERE OCCURS 0 GYP. BOARD METAL STUDS WALL FINISH AS SCHEDULED BASE AS SCHEDULED g PROVIDE AND INSTALL: -NEW 5/8" THICK TYPE 'X' GYP BD ON 3.5/8" MTL. STUD PANELS TAPED AND MUDDED FOR LEVEL 4 FINISH AND PAINTED PER SCHEDULE. 53 -NEW BASE AS SCHEDULED (SERVICE AREA NOT IN VIEW BY PUBLIC)_ w 0 STAINLESS STEEL OVER 1.1/8" PLYWOOD - EASE EDGES i (SERVICE AREA SEEN BY PUBLIC) X18 GA. TOP TRACK GYP. BOARD ON /— METAL STUDS WALL FINISH AS SCHEDULED BASE AS SCHEDULED C1 PROVIDE AND INSTALL: -NEW 5/8" THICK TYPE'X' GYP BD BOTH SIDES ON 3.5/8" MTL. STUD / PANELS TAPED AND MUDDED FOR LEVEL 4 FINISH AND PAINTED PER SCHEDULE. -NEW BASE AS SCHEDULED -PROVI DE/MATCH/INSTALL CORNER GUARDS/ FINISHES SIMILAR TO EXISTING PART HI WALL 54 (SERVICE LSEEN ENOT IN RVICE AREA AREA Q BY PUBLIC) VIEW BY PUBLIC) GYP. BOARD ON METAL STUDS w 0 0 WALL FINISH AS SCHEDULED 101, r BASE AS 0 SCHEDULED OPROVIDE AND INSTALL: -NEW 5/8" THICK TYPE W GYP BD BOTH SIDES ON 3.5/8" MTL. STUD / PANELS TAPED AND MUDDED FOR LEVEL 4 FINISH AND PAINTED PER SCHEDULE. -NEW BASE AS SCHEDULED -PROVIDE/MATCH/INSTALL CORNER GUARDS/ FINISHES SIMILAR TO EXISTING PART HI WALL IBC 1004.3 POSTING OF OCCUPANT LOAD Every room or space that is assembly occupancy shall have the occupant load of the room or space posted in a conspicuous place, near the main exit or exit access doorway from the room or space. Posted signs shall be of an approved legible permanent design and shall be maintained by the own or authorized agent. OCCUPANCY CLASSIFICATION PRIMARY OCCUPANCY CLASSIFICATION = ASSEMBLY A-2 (UNCONCENTRATED) ***SEE "EXITING SUMMARY" TABLE FOR FULL LISTING OF SPACES AND USES AREA PRIMARY CLASSIFICATION GROSS SF CRISPY TOWN ASSEMBLY A-2 2,360 SF CAPACITY OF EGRESS (TABLE 1005.3.2) ALL EXIT DOORS SHALL BE PROVIDED WITH PANIC HARDWARE EGRESS CAPACITY FOR EXTERIOR DOORS (1) EXIT INTO CONCOURSE = 690 OCCUPANTS (1) EXIT INTO REAR DISCHARGE = 180 OCCUPANTS TOTAL EGRESS CAPACITY = 870 OCCUPANTS MINIMUM NUMBER OF EXITS (2012 IBC SECTION 1021.1) REQUIRED EXITS 2 ACTUAL EXITS 2 EXISTING FIRE—RATED WALL ---------------------- WALL TYPE LEGEND --------__-- LIGHT DASHED WALLS, DOORS, WINDOWS & MILLWORK ............ ... ... .... ... ...... TO BE REMOVED EXISTING PARTITION WALL TO REMAIN i' EXISTING CMU BLOCK WALL y ' 7 NEW PARTITION WALL — SEE WALL TYPES NEW KNEE WALL 55 ) (55.3 CE 03 e EXISTING I o0 N 1 FIRE -RATED I. WALLF- �. ...... ............... o........ ::.... \ E r_.. EXISTING DOOR 25+3• EXIT DOOR 1 ®... f : EXIT #2 e 1 72 CLEAR .................... ...:...... ' ()@ : .. !W7NEVEX, — »• ' 3600CCUPANT :....:::. ,.'aftftw ...:..:::::::: (1).@ 36" CLEAR a 1 EGRESS CAPACITY 180 OCCUPANT ` l . -EGRESS CAPACITY (E) FIRE -RATED EXISTING DOOR �'101-101, I EGREESSSS e CORRIDOR ® 31'-6" EMERGENCY ILLUMINATION FOR BUILDINGS AND DURATION OF ILLUMINATION (1008.3.2--1008.3.5) In the event of power supply failure in Rooms and spaces, an emergency electrical system shall automatically illuminate all of the following areas: 1. Electrical equipment rooms, 2. Fire command centers, 3. Fire pump rooms, 4. Generator rooms, 5. Public restrooms with an area greater than 300 square feet. The emergency power system shall provide power for a duration of not less than 90 minutes and shall consist of storage batteries, unit equipment or an on-site generator. Illumination level under emergency power, the lighting facilities shall be arranged to provide initial illumination that is not less than an average of 1 footcandle and a minimum at any point of 0.1 footcandle measured along the path of egress at floor level. Illumination levels shall be permitted to decline to 0.6 footcandle average and a minimum at any point of 0.06 footcandle at the end of the emergency lighting time duration. A maximum -to -minimum illumination uniformity ratio of 40 to 1 shall not be exceeded. 56 '1 COMMON PATH 2T=11 1/2" TING FIRE -RATED WALL ® e e .� woo 130' TRAVEL DISTANCE TO EXIT DISCHARGE FROM THIS POINT ND 63' COMMON PATH COMMON OF EGRESS EXISTING STORAGE FIRE -RATED 102 WALL 57' RL DIS NJ)�Z_71N TO CONCOURSE 26 = FROM THIS POINT EXIT 1:1U. LJ L. 2015 IBC SECTION 1008 MEANS OF EGRESS ILLUMINATION REQUIRED The means of egress serving a room or space shall be illuminated at all times that the room or space is occupied; illumination level shall be not less than 1 footcandle at the walking surface. The power supply for means of egress illumination shall • normally be provided by the premises' electrical supply. In the event of power supply failure in rooms and spaces that require two or more means of egress, an emergency electrical system shall automatically illuminate all of the following areas: 1. Aisles, 2. Corridors, 3. Exit access stairways and ramps. In the event of power supply failure in buildings that require two or more means of egress, an emergency electrical system shall automatically illuminate all of the following areas: 1. Interior exit access stairways and ramps. 2. Interior and exterior exit stairways & ramps, 3. Exit passageways, 4. !Vestibules at level of discharge, 5. Exterior landings and areas t used for exit discharge. 56.6) ( 57 FVl'RE:LIVED FOR OMPLIA(VCI APPROVED AUG 2 9 2016 'LEASE LINE IBUILDING �rRY fTukwila DIVISION I I EXIT #1 TO CONCOURSE 11'-6' BETWEEN 43' RA V DL5• NCE _ _ SEATING PARTITIONS 690 OCCUPANT -� W TO FR M TH POI T 1�-1� EGRESS CAPACITY 0 U 27'-2" Ir NEW DOOR J L --17.-J 1 EXIT DOOR ASE 1 150 OCCUPANT EGRESS CAPACITY E .. :.:.... •.:o:::......E :: .. w•..:;w� ::.iJ?I_.,.:w:mow; :::: ............ .1L.... _ 1 ___j r F _TF 71 Lj L .L.` AUS3 '19 20 6 �CTI. 0J Ta6V.iff CENTER AM Awmm� 1111% ,. EXITING PLAN SCALE: 1/4" L 1'-0" U) W n J J Q 0 Z J J O CJ i w0� W � N (-)< �, 'S O Z Z) <z J �= O =j w >< U W ��Q V_�_n DATE ISSUE 07.20.16 PERMITE S T 08.17.16 REVISIONS Cj G-0.2 2016-11-00 N r _N E C U) 0 4- 0 N 0 0 0 N M 00 N V 0N C U N CL N N Q Q N (6 = U) 00 O C\j N N Lo U) 0- N U) W n J J Q 0 Z J J O CJ i w0� W � N (-)< �, 'S O Z Z) <z J �= O =j w >< U W ��Q V_�_n DATE ISSUE 07.20.16 PERMITE S T 08.17.16 REVISIONS Cj G-0.2 2016-11-00 .............. ............................................... .. . . . . . . . . . . . . . ..................�................................................ - . - . - . - . . . . . . . . . . . . . . . . . . . . . . . . . ...... - . .. ............................................................................ ............................... � .................... . , ............... .............................I. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . , . . . . . . . . . . . . . . . . . . ...-...-...................1 ............................................... . - .,................................................. ....................................... ........................................................ . . . . . . . . . . . . . ................. .............. . . . . . . . . . . . - . - .,........................".,�.. .............. I .................... a) U) :!:� L_ :3 a) ..... I . ........................ . . . . . . . . . .........................................,....................................................... � ................................................................... ........................... %,.,........ ...................................................................................................... il"**"***""""***"*"'*"""""'*'l***"""*""'**111*1*""""",*,**'*"**""""".11**"'**""*'*""""""""'I"*""**""*"""'*'*""'*'"****"*,"."*""*"""'*, ............................. ................. . . . . ............................................................ . . . . . . . . . . . . . . . ................. . . .............................................. ..... ......................................................................... .... .......................................................................... ........................................... . . . ............................... . . . . . . . . . . . . . . . ............... . . . . . . . . . . . . . . . ............... . . . . . . . . . . . . . . . .......................................,.....................................................................................,..................................AP,Ezl-IIOP.'.'.'.*.-.'.*.'.*.'.'.'.*.,.,.*.*.,.,.*.,.*.-.,.*.".,.,.,.1-1.1.1-1.1-1.1-1.1-1.1.*.l.,.*.,.*.,.*.*.*.,.,.l.'.,.'.,.,.*.'.".'.'.l.'.'.*.'.'.*.'.'.'.'.'.*.'.*.'.'.'.'.'.'.'.'.'.'.'.*.'.'.'.'.*.'.'.".'.'." .................................................................................................................................................................................... d- =3 0 2 ca -00) 00 c: C) >1 ...................................................... ........... ....................................................... , ­­­ , , , " * , , , , , , , , , , , , , . . . . . . . . . . , . . . . . . . . . . . . . . . . . . . ........ ............. .''''', .............. ........................... 1_'_'-*_'_'-*-'_'-*-'_'-'_* ..... * , , , '' * * -........I.-...-.-.-...-- ....-.-...-.1 .... * ....... * '' * * , ..... I .......................................... - - - - - - - - - - - - - - - - - - '' * ...... * * '' * , - - - - - - - - - - - - - - - , * ........ * ... 1-"-'.'.'-'-'-'-*-'.'.'.'.'.'.�-'.'.--,.,., - - - - - - - - - - - - .,.. :!:� 0 0 = CL 3! c%j -, 1pi.s.c.i�i�j�c..............................................................................................I.,.,.".,.,.,.".,.'.'."-"'.,-,---*-I-,-*-'-'-*.'.*-'-*-*-'.'.'.'.'.-.'.'.'.'.'.'.'-'.'.'.".".,.,.,.,.,.".,.,.,.".,.,.*.,.,.,.*., I - - ....--.....-.-.-.-.-.-.-.-.-.-.-.-.-.-- . . . . . . . . . . . . . . .. ............ ............... . . . . . . . . . . . . . .. ... .................................................................................................................................................................. .......................................................................................................................................................................................................................................................................... 3: -5 Lo W a -_.-.--_._-_-----.---_._---_- ...................-.-.....-.-.-...-.-...........-.....-.-.....-- .-.-.-.-...-.........................-.-...-.-.-...-.....-- ...-..............................- .....-.............-.-...-.-.---...-.-.-.....-.- ........ ;�*C'ONTRACTORIQ'W�Rlr-Y ........ ............................................................................................................................................................................................................................................................. ............... . . . . . . . . . . . . . . . . . . . .. . ..... � . . . . . . . . . . ... . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . I ........................................ * ..... I . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .... . ... . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ................ . ..... , . . . , . . ....... . . . . . . ... . ... . . ....... ".*.'.'.'.'.'.'SOUNDARtaS'AND.DlMaNSIONS*.'.'.'.'.*. . . ............................................................... .............................................. ................ ........... ...................................................................................... " " """ ** , ........ ....... ....................... ....... ..... ............. . ................................................................................................................ ........................... . ............................... .................................................... .. ......... . - '80UNI)ARIE90"'IM E'N SION S--*.'-'-'-'-'-*- .... I..... ................................................................ . . . . . . . . . . . . . . . . ... ... , . * ............................................................................................................................................................................................................................................................ 1"""*"*"'*"**""*'*'**'""*"'*"'**"*""*"*""'***""* . .......................................................... . ............................................................................................................................ PENDANT LIGHT FIXTURE t ODE COMPLIANCE ` z ... . . .......... . . . .......... . . ARE'APPROXIMATE.&. FOR.'.'.'.'.'.'.*.'.' . . . . . . . . . . . . . . ... . . ...............................................................................................................................................................................................,..................................................................,.....,...........................................................,...............................,.......................�.................................. . . . ........................................... ........ . . .......... . .A,.,.,.,.,... ------ �ZZ.ZZZ.ZZ.Z/-ZZ-Z-ZZ-�/-/-/.,/, - .. - ............... ......... ............. ��, V. -! q ....... . . .............. r..- ..... � ------------- r� - A`4 .. .. ... Z.Z I ZVI . zz-z .................. ,,--.o'z-.z--zz- ------------- y ......................... � - - � 4'.1 -z4z-zjo - - - -_ - I .......... , , - - - Z.11".ZZ t07!7� ... _4 ...... 44z*z 4 --------- t�7 ................................................ -'-�02 z z__ -zz_zz_z- ................................................................. � - - ...4-1 ....... ............ .............. * ki�ri�kl�Nc-r-ONL-Y..-.*......-.-.-.-.-.....-.- I ............................................. .. .............................................. ........ I t� , - , . . ......................... I ..................................................... . . . . . . . . . . . . . . . . . . .,.*." . , ..................................................... .............. ....................... � ................................ ........ . .............................................. , ...... ............... ­­­ .... I ................................................... .................... 7-v - .'F.. - I I ..................... I,- I 11 - - - , - .. ­ I I I!, , i I � , * '' * ''1"*'*"""""'.-.-.-.-....-�..--..-....-.....---.-..-..-.-...--.-...-.---.-..-.....-.-.-- ... '' * '' * .............. , . '' ­ ­ I , - - - I - I ... I . . ,!!, -7 -77 , I I 111. � I ... ­ 1. � ... -11 ... I .... �. ................................ - . ................ I ............. �. -..,. . ,!. T - � "l -r ................... .. , � * , * ....... * ........ * ... , , , , * , , , ... * * .... ... . * ................... *`[`-,-**`*' ­* , , , , '' ­ " ____` . * .... .. ........ .. . .. ................. , * _*_`*""` . , . , . , ...... * ............................. , -I""' "'I"' `1'1'1*`"*1'1*""1'1'1'1'1` 1,1*1 *'* "I",*," * ..... *­ ... * ­ * .... * .............. * , '' ­ * * , , , '' * , '' * ...... ..................................... ......... .............................................. ... ............................ .............. ......... ......................... .. I' .! 11 ........................................................ ....... I ...... ....... I .................... . ............. � ....... . ............ ................... ...................... ................... . .............................................................. ...... ....... ... .. I . . . , , I ...... .................................................... ............................ .. ... . ... ....... ............................................................... . . . . . " * ... , .. .......... . ..... ........ . . R&I ....... . . -h'ff ........................................................ ..... Ev, .. ....... -.1, .. .................... .. J37.* .. . .............................. ........ .. ...................... ................ ........ ...................... .......... , .............. ........ .................................................... .......... ...................................................... .............. ......... ....................................................... ............... ............ . r= ...................... ............... ................... .. ... ... , , * . ... . - - - - - ...... ......................................................................... ... .. , ............ ................... .. .. .................................... . I ................................ . , orl�,?-' 1,:� - . - . - . - . - . - - a-� V,i,r ...... IN.Scf , I )R - . ............................... . - . - . - . - . . . - . - . - . - . - . - . - . - . - . - . - . - . - . - . - ............................... ............. ........................ ... ....... ........'... .......................................... , .............. ........ ......................... .., , , '' -EY - ­........,. ...... ,1W_. . ... I .. - - - I - .. ..... ..................... ....... ....... , * '' * '' * * - - * ... , , '' * * ­ * * ....... ....... ............ ....................................................................... . ...... . ...... .. .... . ...... ................. ... I .......................................... ............... I ......... ........................ I ...................................... ........ ...................................... ....... ................. I . * .... ..... j5Lc_.?-)1�o*p ....... ................ .... . ... , ............................ ... I ........................ ........ ........ � ....... ..... .... I .1"""' . ............ ............ ....... . .......... . ..... ............. . I . . .... .".,. % *.,.,. . . ... ...... I - 1. ............................. I ... I ............... .... ........................... ................... I ..................................... ................................ ...................................... .......... I ..... ...................... ....... ....... 6l" , , , , * ................. ..... ................... ,�,.,.,.*.,.,.,.*.,.,.*.,.,.,.,.,.......... ....... . . . .............. 7U�*6U_ft ..... ...... ........... ................. '' * ................ ......... ..... . ....... .. *.'.'-*.'.'-'.'-'I*.'-'.'. ....... . . . . . . . . . . ........ - - - - - - 19m ........... .......... -'.'.'.'.'.'.*.'-*.*,'-'-'-'.'-'." . ............. ........................... , [ �.. . . = ......................... . . . 1 - - -- - '''' � � ... * . ... ...... .................................................,................... .......... .............. . ..... .................. ......... .................... .................... -!_or ......................... , F, - . I.. ­.... ........ ...A� X.0 ,:-. - ....... ... .. I ....... h ..... * ... * , . I ....................... . ........ � ............................................ I....... ................ -.*__v- -'A ...... . .... ..... ..................... .............. - L . - ­.. ' r4- =__'_---- L - - 2 . ........ . ... ........................................ - - ....................... ............................ . ...................... I .......... .... - - - '' -I ..... . 11 .. .. .. . .. .. .. .... .... * ........... ........................ 11 .. .... ............ . .. ............... .... EM - - - - . . . . .... .... . ... ... � .............'...... I .............. ............................................,........ ......................... .. .... - - . .. .. 0... ..................................... *** ...................................... I.... ... '' * '­ , .................................. .. ... .............................................................................. .. ::� F-��.\Z.j--_-..---.-..'-- *.''.*.'.'.'.*.'.*-'-*-*-*-*.'.* ............................. . .............................. . ... . .. .............. -.-' ..... .-. , ...... I I ...... I ............................................................... .......................... ..................................... .......................... .... ............. Ak ....................... ....................... . . . .... ............................................ .............................................. ........ .......................... ......... .. .. ........... ..................... I . . ... ... ........................................ . ..... ..... ...................... .... ... ... * .... ... . - . . ..... . . . ................................. � .............. , . . . ..........��, .......... - . . , , , .. . .......................... ......... ... , , I .......... . 1. I J:::::: J��:�:�:�:��LPCJ LL, , , � - , 1:z-._-- --- 17-1 . .......... . . * ........... . . .._..... I... I , , , , I (M TT ............................. .................... ...... .D� ............................. �� ............... ............... .. �� ............................................ ti� . _.... . . . . . . . . . . . . ............... �................................... 0A. . ....... ...... � ., . . . ...... .. .. . .. .................. *_'-%'_'_*. . . ........................................ ........................................ ....... ........................ - ........ ..... ........................................ I . ......................... - - .. .................. ......... ... .... . - - .!W , , * . ...... ... , , 111,� 11,1),�,;� ... � ... - '' ,��, 1, ,�,, 11 e ee _____� .'-'-'-'-'-*.*.'-'-'-'-'-*.*.'-*.'-'-'.'.*-'-'.*.*.'.*-'-'.*.'-'- .* ......... .... ..................... (� : ..... . ....................................... ................ .......... � I , * , * , , .... _ ........... ................... - - , * , , * , * , , , , , , , , * , , ..... .......................... ......... ............... . - ' ' ............... � .... . ...... . . . . . . . . .... .. 1 . ... �. .''.., . ... - . ... " , 4 'ED � - - Hui 'I . _�_ _# - . ... ...... .............. ............. [m ..... [N ................................... , * .... � . ­­...... ............... ..... . ................. ... , .................... ­ * ....... ... ­­' '' * * ­ * , , '' * .... ................ ..... ........................................ . ­­­ .................... ­ * ................ * '"' ­ * ....... * ......... * ................. * ... , . . .. . , , , , , , , , , , , ... ........ � . .............. _ .. . - - - - - ............. ...... - * , , , * * , , , , * ' ' E ... . I . . . � L ffil �j I . . . . . . . . . . . ... . I . . . . . . . . . ..... ............................................. . . , . " ................................................ . . . . . . ......I.......... . . . .. .......... . . " M. * , , , , , , * , , , * , * * , , .................................................. ................... - - , , , , , , * , , , , * * , , , , I I , I ... .... .......................... ......... . - ' ' '.- . ..... �. .'.'- . . . .. , , , , , , - . *�­ , , __ ... ... � LL J a S 0� . . . . . . . . . . . . . . . . . . . . . . . ....... ............. d.... . . . . . . . . . I—* . . . , . . . . . . . . . . . . . ...". . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ................ . . , . . . . . . . ... . ........ . . . . . . . . . . . . . ..... ................................. I, � � . . . . - - - - - - - - - - - - - - - - . . .......... .............. ........... �-V_%V_ . '. .. , . , . , . , . , .... .......................... ......... . ........ I - - - - - - - - - - - - ..* - - - -, - - - - - -, - - - - - , * , ....... ........................ * ........... .......... �.,.,. . . . . . . .... - ... - - . .......................... ......... . ......... * * .......... - - - - - L. � " - . ..... .. . . , ..".11".1.7 ...... ...%. I I � , ­­ ... * , . '' ­ *­ . , , . , . , . , . , i R :] (� I 0 ................. . . . . . . . . . . .................................................. .................................................... ........................................................................................................................... . . . I . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . I .... I ..... ........................ - - ............... ....... . . . . . . . . . ......................................... . ....................................... .......... .................................. . �� ... ........... ........... E.* ................. E * _.".......... .. .....I. ....... .... I . . .. ................ ......... . ... I ................ * . ........ . ......... ................. � ... . . ........... .... * . . I ::'':6-1 ` - ........ ­.. ..... .......... ........ ..... , ­ *­ , 0 (&QDQ� ) .............................................................. ........................ ....... .. ... ..-..-............................................................ ........ ....................................... ................ - ............... I ............. .... . . - . - . - . - . - . - . - . - . . - . - . ... I .......... ................ ......... ...... ... ............... ......... ........,.V. _..-___---_-_.--_ . ............................ I............................. ......... . . ........................... ......... .............. ... ... .. ... _- ..... . ...- * ­ ..... ........... .... ..... ........ I . Ll QDV_ - ..... .................... �.-.-.-.-.-..,.,+-......................-.-.-.-,-.-.-.-.-.-.i.-.-.-.-.-..-.-.-.-.-.-.-.-.-.-,-,-.-.-.-.-.-.-.-.-.-.-.-.-.-.-.-,-.-.-.-.-.-.-.-.-.-.-.-.-.-.i.-.-.-.-.-.-.-.-.---.-. ......-.... ....................... I..... ................. .-.-.-.-.A-n.r7tl.l,fo--.-.-.---.-.-.-.-.- ..........''...........,............... ,T------_---.-----_- . . ...... .. ............. . .............. ... ..... . ............... ............. ..... ................ .... ................................... i - - ... ............... ...............'............ .... v ...... *.,.,. ... :1 I ---::-_-_ BE ... ...-.-...-.-.-.-.-.-.-.......................-.....-.....-.....-.......................-.....-.........-.-.............-.............-.....-.......-.......-.-...........-...................i�i ......... .............................................. ......... . ................................................................................................................... I ................................... ............................................... . ....... . ..... 3r;,.oFL;.1.1 ........ I ....... I .. .............................................. ... .... ... ..... ............. ..... .. , ................... * .. ... ............. .............. ............... ... .......................... .. ...... ......... .............. ............. ... ...... I ................... ... .... .......................... .............. ............... ..... . ...... ...... .... ... I .................. ........ ....... ...... .......... , , ............... " '' . ............................... , , * ........................ , , ....................... , . . . .... . I ........ �- no un m I ,:� 1, ­�� ,�,,,' ,_,� ... ,,, , I _�, I :1 1, , ,;;;; - 11 �_ 11 ,, 1, " ................................ ............................................................................................................................... ................................ .. . ........................................................................................................ .................. . . ................................ .......................................... I ......................... ............... .... .............................................. .............. ............... ............................... . .............. ............. ................................ I' . . . . . . . . . . .............. ............... ............ . - .................... ....... I ........................ . . . . . . . . . . . . . . . . . . . , * , , ... . ... . , _p - 1-11,111-1- -_ .0 � . � �7 I -1_11 � ,.. 11 'I . -4 s I I , 11 ........................................................... .............. .................. . . . . . . . . . . . . . . . . , . . . . ............................... ......................... . ............... Im . um . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ..............................................,.......................,..... .............................................. . . ........ ....................................... .............. ......... v .......... . . . . . . ................. . . . . .......... 17 ........ .............. ..... ....................... . .............. ......... ... ................................ .... .... " . . . . . . . . . . . . . . . . . . . ....... ................ ........ . .......... ..A " nj�4-ji(?T ......................... .,.,.,.,.........,.......-. . ..... . FIN W . . . . . . ............... . . . . . . . . . . . . . ............................................................................. ......................... I ...... ............................... , ......... . . . . . . . . . . . . . . . . . . . . . . . . . i - - - - - - - - - - - - - - - - - .................. ............................. � . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . - - - - ................................. I .............. .............................................. � ... . . . . . ........................................................................... . ........ ........ .............. .......... ............... ......... . .. . ..........,......................................... . . . .............. ............... ............................... ............... ............. = ........ * ..................... .............. ............... ................... .............. � ........ ....... ............................... ............. ............... .............................. ............. *.. ...... ............................... ....... .............. ............... .............................. ............... ............. ............................ ..................................... .............. . ........................................................ ........................................... ..................................................................... . .............. . 1Arsc0PE-'-'-'-'_'-'-'- .......... ­­ ........... ................... .............. ................................ '' ­ * ­ ................. ........ .......................... - - - - - - - - - - - - - -, -11111 ... I * * ''I , , .......... , , *_ '­_ ..... ''' , ......... .. ... DO L!�m AL ___, L ___0qq1 1___� . ======m ............................................................... .............................................................. . ........................ I ...... ........ ...................... .................. ............................................ Lr..*.*.,.,.,.*.'.'.'.'.'.".'.'.*.*."*.*.*.*.*.'.'.'.'.*.*.'.".*.'.'.'.'.'.'.*.'.'.'.'.'.'.'.".".'.'.'.'.'.'.'.......'] ................................................................. ............................................................... ........................ .............. � ....................... . ........... . ....... I ............................. j.l* . ..................... ..... ..... ..... " * * I I * I I I * - * ....... ............ I ... ....... . , , '' ­ * * ..... ......"', . .................... ................ I .................... I @ & 4 D 0 & % ............ ..................... ............... I , .................... I ................... ........................................ .......................... I ............. ................................... _­ - ..... * I.,.,.,.,.v.,., . *.,.,.,.,.*.*.,. 1. v.v.,.,.v.,.,.,.,.,. 1. 1. I.I.I.V.I.I.I.I., I I I I I * ...... * , , '' * * ­ ......... ­ * ....... ­ * , .... **** ...... ....... I ................................ I .... ........................................ ........................................ ........................................ .............. ................ ............................................................. ............. .................... I .............. ................ ............................................................ . ....... '' * * ­ , , , , , '' * ­ .............. .............. .......................... .............. I ................ ......... ............................ ­ * ... ............... ............ * . ............................................... .............. .... I ........... . I .............................................. --­ I. '' ­ ............... ............. . .... .... ............................................... ...... . .... ... ............ ... --v..... ..... I ........ ...... ­ . ............... .............. ..... I ........ 11.1, "".1' . ............................................... . ..... .............. .............. ..... ` .lr.-.,j ................................ I...............................................................................................I ............... .. ... ....... ...............................................................-...,���i�.;.i. .. ........ ................. . ....... ... ...... ... ...... . ...... ...... - - - .. .. - ... ... . ... ............... .............................................................................................. .. . , , , '' * ....... .............................................................................................................. .... ...... ............. ........ ........ .................................................. I .......... ...... . . ........ ..... ... , . ....... _� ........................................ - � ........ ............ �............................................. ........................ I .................. ... . ...................................................... , . . ................................ ........... I - � .. ............... ............. ............... ........ . ..................... ....... ....... I ...................... I ........ ............... ..................... . .................... .................... .. I ..... .................... , - ................. .............. IR if ...........,...............,.,........... ", * � 'EAV ........ ... / J1 " . ...... ........................................ . . ..... ........................................ ...................................... ....... . . - ............................... ......... I ..... ............................................. ............................... . . . . ........................................ ................ I ....................... ........................................ .1 .............................. ......................... ......................... , ...................... .............. ........ I .... ........... i . ........... .............. ............... ......... * . ................................. - .............. ............. ............. ............................................................. .............. ............... ........... ................................. . .............. ............ * ............. ............... I ............ 1. .... 1. I ........ ........... ................................................ . ........ .............. ............. ............. .......... .............. ............... ........... ............................................................................................................... . .............. ............. ............. ................ - .............. ............... ........... ....................................................................................................... .............. ............. . I ........... .................................................................. ............... ........... ....................................................................................................................... ....... ................................................................................ a ................................. .................... I ............................. * . ............................................... .............. ....... � ......................................................... I ................. .. I ..... .............. *.,............................................................ .... .. .............. . , ........ .... .............. I ..... . . .... I .. . ................................ ................. .................. ................................ ... ........... ..................... ................................ . ......... .. ............................ .. * , ''' ­ ........ . ... iN-*9�()Pt".'.'.'.'.*.'.'.'.'.*.*.'.'.'., ....................................................................... , ........... .................. ................. . ............................................................................................. ............................. ................. .. .. ....................................................................... . . . ............................. ................. - .... ............................................................................................. . ............................. ................. - . ................................................................ .... ............................. ................................................................ - .......................................................................................... ­­ ­ ...... * ........................... ­ ­ .............................................. ........................................... ­ . .. .. .. .. . ... .. . .. .... .............................................. .............................................. .. .. ... .................. .. . . .............. .............. ............. ............. ........................... .............. ............... ........... ................................................................................................................................................................................................................. ............... ...... , ... , .. ...... ­­­ , , , * ...... ** ...... .............. .............. I . ........... . I. ............ I ..................... ....... . ..... ............. .................. ...... I I ................ - ................................... .......................................................... ........................................... ....... ........................................................................................................................................................................................... ........................................... ................................ ................................................................................................................................................................................................... . . . . . . . . . . . . . . ................ .. . . . . . . . . . . . . . .............................] 1.*.*.* ........................................................................................................................... ___ __ .. I ........... . . .................... ............. ............................. . . - .............. .......................... ........ ....... I' * ... * ...... I , *' - - - ........ ............................................... I ...................................... . .. *­* ... ­* ... . .. ............................................. . ...................................... . __ J."'.'.-.`-.`,.'.".'.'-' , , , , ............................................. .............. .... .... .......................................... ­­ ...... ­­ . ......................................................................................................................................................................... .. - ................................ * ... * , , '' ..................... .............. ......... ­' '­­ .............. ...... ........ ....I ......... I.........''............4 . ....... ........ � ...................... ... . .................................................................................................................................................. ................................ . * , , ....... * ........... , ..... ................................ ....... ......................................... .... ..................................................................... ................................ .................. �. . .................................,. � ....... . . ....................... ................................................................ . . .. ­ * ..... ** ......... ­­­ ... * ...... :**­­­­­­* ............................. ................................................................ . ....... ............................................................... . . -1 . I ........................................... .............................................................................................. ............................................................................................. ..... .1..................................................,...............................I ........ *­'­­­­ ............... I .............. .. ....................................... 1. .. � .............. .................. . ........... .............................................. .............................................. ......... I ........... I ................................................................................................................ ...................................................................... . I ............................................................................................................ ................................................................ I ............................................................... I ............................................. v I..I,��.".'.'.'.'.*.'.'.'.'.'.'.'.I*.'.* . .................... ..................................................................................................................... ....... ................................................................................. . ....... � ..... I .................. .... ..... ............................................ I . . . I I ................................... � ..................................... I DEMOLITION FLOOR PLAN SCALE: 1/8" = 1'-O" LLI AREA ri-G-7- /Al S C 0 P E: + 1"J_XL_�l I I I I I _Atla�,.!. I I . I 1.11 I - r_� 1 fc SCOPE + IL_ - + A, � I + + + + + + + + T N+ A, �- + + + + + + + + + + � �- + # + + + + + + AREA + � : + + + + + + + NOTIN .\ ;;,-;q , (&n I V . � + + + � + - + + - I COP,�- - # - -----= i i AREA : NOT IN I LL=== - - i ... - __ - - r�� - DEMOLITION REFLECTED CEILING PLAN /-_j SCALE: 1/8" = V-0" + # 1 4 - "CONTRACTOR TO VERIFY BOUNDARIES AND DIMENSIONS - BOUNDARIES/DIMENSIONS ARE FOR APPROXIMATE & FOR REFERENCE ONLY" A PL E A N 0 T IN SCOPE **MEP AND FIRE PROTECTION WILL BE SU13MITTED SEP ELY AS DEFE RED PERMITS. ANY INFORMAT19N PERTAINING TO MEP OR RE SYSTEMS SH WN WITHIN THIS DRAWING SET IS FOR REFERENCE ONLY A D IS NOT SUBMI 1TED FOR PERMIT APPROVAL. FUTURE TENANT TO SUBMIT FOR HEALTH f\ - _� EPARTMENT-PERMIT." I i AREA Af 0 T IN SCOPE REmeVE BEBRIS IN TI 118 AREA (PREPAR FOR GO NEW CONCRETE FtOOR SEAtER WHERe GGGYRS) REPAIR AND PREPARE EXISTING SbRFACES TO BE t1KE NEW ED MARLITE PANELS AND L TO BE LIKE NEW. REPAIRE AND INFILL FLOOR TILE WHERE M MODIFIED DURING CONSTRUCTION GENERAL DEMO. NOTES 1. REMOVE EXISTING PARTITIONS AS REQUIRED. PATCH, REPAIR, AND PREP ALL PARTITIONS AS REQUIRED FOR NEW FINISHES. 2. CAP OR REMOVE ALL ELEMENTS AS INDICATED; CAP OR REMOVE ALL ABANDONED PLUMBING/ELECTRICAL DEVICES. PATCH, REPAIR, AND PREP ADJACENT SURFACES AS REQUIRED FOR NEW FINISHES. REmeVE ENTIRE TEMPORARY GONSTRU TION 3. DAMAGE TO OTHER TRADE!S WORK AS A RESULT OF (&n WALUST-GREFRONT BARRIER AND ITS- THIS WORK IS TO BE PROMPTLY REPAIRED AT NO AGGES-S-GRIES - REPAIR AND PREPARE .--..- ....- _. EXPENSE TO THE OWNER AND TO THE COMPLETE EXISTINe S13RFA6ES:fe BE LIKE NEW SATISFACTION OF THE OWNER. (;M GUTENDOPWALLGLEAN REPAIRAND 4. CONTRACTOR SHALL VISIT THE JOB SITE PRIOR TO 12RERARE EXISTING 21 QiA61�i6iR'E=­[ I E NEW .. . . - - ­ ..--- - - SUBMISSION OF BID AND FIELD VERIFY ALL EXISTING CONDITIONS AND THE EXTENT OF THE DEMOLITION REMGVE EGYIPMENT, FRAMES, AP49 ITS WORK. ALL ASSOCIATED DEMOLITION COSTS SHALL EDB . AGGES-R-GRIES RF=PAIRA�iPPREiPARFz.F=X!S:Pi�ir, BE INCLUDED IN THE BID PRICE. NO EXTRA PAYMENT 5U%l ACE8 TO BE tIKE NEW WILL BE ALLOWED FOR WORK REQUIRED BECAUSE EXISTING WALL AND COUNTER TOP TO BE OF DISCERNIBLE CONDITIONS, WHETHER OR NOT REMOVED - REPAIR AND PREPARE EXISTING SPECIFICALLY SHOWN ON THESE DRAWINGS. ) = SURFACES FOR NEW COUNTER AND 5. THE EXISTING BUILDING INCLUDING PORTIONS OF EQUIPMENT. THE RENOVATED AREA SHALL REMAIN IN SERVICE REMOVE PORTION OF CONCRETE SLAB - REPAIR DURING THE CONSTRUCTION PHASE OF THIS (M AND PREPARE EXISTING SURFACES TO BE LIKE PROJECT. ANY MODIFICATIONS TO THE EXISTING NEW - COORDINATE LOCATION W/ FUTURE ELECTRICAL SYSTEMS THAT MAY REQUIRE THE EQUIPMENT TEMPORARY INTERRUPTION OF EXISTING SERVICES SHALL BE COMPLETED AFTER THAT MAY REQUIRE THE TEMPORARY INTERRUPTION OF EXISTING (6M INSTALL NEW DOOR AND FRAME. ADJACENT SERVICES SHALL BE COMPLETED AFTER NORMAL SURFACES TO BE PATCHED AS NEW. WORKING HOURS. PRE -SCHEDULE ANY SERVICE INTERRUPTIONS WITH THE OWNER PRIOR TO NEW FLOOR SINKS TO BE CONNECTED TO STARTING ANY WORK. DO NOT DISTURB THE 4( MD EXISTING. PREPARE EXISTING SURFACES TO BE EXISTING DEPARTMENTS IN THE EXISTING BUILDING LIKE NEW COMPLEX. REMOVAL OF MECHANICAUPLUMBING & (M ELECTRICAL SYSTEMS TO BE COORDINATED WITH MECHANICAL/PLUMBING & ELECTRICAL (:: � PAIR ACCESSORIES AND S C ��a��I T I �ON�N 0 �TE �S � � ) PREPARE SURFACES AS NECESSARY TO BE LIKE NEW MGVE ENTIRE GI=ASS PARTATIGN AND ITS Qqn AGGESSeRIES REPAIR AND PREPARE EXISTING ---------- LIGHT DASHED WALLS, DOORS, WINDOWS & MILLWORK SURFAGES Te BE LIKE NEW SEE PLAN FeR - TO BE REMOVED NEW LeGGA:Fle�4 REMOVE ENTIRE TEMPORARY CONSTRUCTION I EXISTING PARTITION WALL TO REMAIN (ON (M WALUSTOREFRONT BARRIER AND ITS DEMOLITION PLANS) ACCESSORIES - REPAIR AND PREPARE EXISTING SURFACES TO BE LIKE NEW EXISTING CEILING ITEMS IN THIS AREA TO EXISTING CMU BLOCK WALL (ON DEMOLITION (6M REMAIN - REPLACE DAMGED ITEMS ONLY - PLANS) REPAIR AND PREPARE EXISTING SURFACES TO BE LIKE NEW I I PART HIGH WALL TO REMAIN - REPAIR/PREPARE FOR ) EXISTING CEILING ITEMS IN THIS AREA TO BE NEW FINISHES am REMOVED - REPAIR AND PREPARE EXISTING SURFACES TO BE LIKE NEW CONSTRUCTION WALL TO BE REMOVED - ) (im REMOVE CEILING/ROOF ELEMENTS IN THIS AREA I `,�� * � `:` PATCH/REPAIR EXISTING SURFACES)PREPARE FOR FOR NEW RTUIDUCTWORK - REPAIR AND NEWWORK PREPARE EXISTING SURFACES TO BE LIKE NEW ( S!�n�T�E§_���� (:: � S 1�� �2L S�- L ,EG �EN D�S � � PHOTO DEMOLITION - SERVING COUNTER SCALE: NONE PHOTO DEMOLITION - NEW EXIT DOOR SCALE: NONE MECHANICAL DEMOLITION NOTES 6. REUSE (E) INFRASTRUCTURE. ADD/REPLACE MAKE NEW CONNECTIONS. 7. ALL FIRE PROTECTION SYSTEMS TO REMAIN IN PLACE AND OPERATIONAL DURING DEMOLITION PHASE. 8. SEE MECHANICAL DWGS FOR MORE INFORMATION. ELECTRICAL DEMO. NOTES 9. UTILITY OUTAGES: NOT LESS THAN 1 0 WORKING DAYS (VERIFY WITH LANDLORD) . PRIOR TO A REQUIRED UTILITY (POWER, TELE, NET) OUTAGE, OUTAGE FROM THE FACILITY. NO APPROVAL. CONTRACTOR SHALL LOCK -OUT AND RED -TAG THE APPROPRIATE CIRCUIT BREAKER, SWITCH, ETC. RED -TAG SHALL INDICATE WHEN THE OUTAGE WILL BE TERMINATED, AND A TELEPHONE NUMBER TO CONTACT REGARDING THIS OUTAGE. THE TAG SHALL ALSO WARN PEOPLE NOT TO RE-ENERGIZE THE CIRCUIT SYSTEM BECAUSE OF POTENTIAL DANGER TO PERSONNEL AND EQUIPMENT. ALL WORK ASSOCIATED WITH ANY POWER OUTAGES SHALL BE COMPLETED AFTER NORMAL WORKING HOURS. 10. SEE ELECTRICAL DWGS FOR MORE INFORMATION. 04 CEILING MOUNTED LIGHT FIXTURE T_ Irl, a) U) :!:� L_ :3 a) E 0 a U) 0 c Z M -I.- Jc� d- =3 0 2 ca -00) 00 c: C) >1 ?: . - ca Irl - m 00 C,4 5 U) 3� (3) 'IT r t04 QD) It < " M E :!:� 0 0 = CL 3! c%j a) 0 .!:: - 'T L_ < < A (o cn CMI) i> co *� 0 > C\1 CU 04 3: -5 Lo W a - a) on 5W RWnTmMWD I �� ' Aft� k L �'OF ��WUANMWW40M ' �STAU 0q. 20-zo 10 0 CEILING MOUNTED LIGHT FIXTURE + SUSPENDED CEILING MOUNTED LIGHT FIXTURE 1'x4'PENDANT FLUORESCENT LIGHT FIXTURE l'x4' FLUORESCENT LIGHT FIXTURE - SURFACE MOUNTED L� 2'x4' FLUORESCENT LIGHT FIXTURE z 0 CEILING MOUNTED LIGHT/EXHALIST FAN � /_ � � _1 RECESSED CAN LIGHT FIXTURE . - a- , REVIEWED F OR (9 -N cp--./ PENDANT LIGHT FIXTURE t ODE COMPLIANCE ` z . ,. APPROVED _j AUG 2 9 201t . W . 0 City of Tukwila BUILDING DIVISION r) - _-_ - * -- * '77�7­­­='7- W I I I � '� 1 , I � , , / , 'I �� _� � � 1. ,� , , , , ,; � I � " , , " , , "/ I i - � I � I /", �, "I �, � /I - � , I "�,�� , , , " I ""/ , <1:0 I () - I'll, , , I I I 1, " "' " , , " , , "I , �, ,,, ," I I I I "I .......... ,_� ,_ I 11 I I . ..... . , W "I I ,/ I 11��1'11� 1, " 11""", I ,� 111�1/1 I , 11 , , _��"",��,'�',,I/�','�' I , , 111,� 11,1),�,;� ... � ... - '' ,��, 1, ,�,, 11 e ee U. , I I I I W 11N, 1,111, � I"- � 1� ... "I , I 0� 11, I 11, , ,­- , , � , 11-1 "�,� 1, � " 1'� , 11 ", 1111�,' �,,,�/<11, ,��,,,' I """ ­,"" I. - I'll __qm 06 ,',,',� � ... ",§� ,,,, ", �` �11 /,,:�m ,11 I/,/,,,,, "' " 11 "I 0� , ­�F",,,� 11 ­­ !""""""', � ,,,,,,,,,, _;,11, I , "'ll "" 0 I , I , '111 I I I 1 , 11111 � I �' "',", 11 0 � � , '1111111-11 ,�� �­� I -'a , 11 ... _j ,,�,, - 1�0 11::::: � �, � I'', '_ I U. _j I I I If , 1117 "Ill,����",,',���'�'�,,�,�,,��', 11 -1 �, � ,� /, , , � " 1� M"'I": ,`�!,:,`!`�,' I , '­ I I _j < 0 05 I 1-1 "I'll � � I'll 1:1 11 �,`. , , , -11, 11,11141 I ��/ 1- " I 11 � "i I'll 11 1 I ,,�� 11 "I , 1, 1; "I'', I" ''I I , '' " �:,,,,__ i I ­ z !>- C) 0 I ,:� 1, ­�� ,�,,,' ,_,� ... ,,, , I _�, I :1 1, , ,;;;; - 11 �_ 11 ,, 1, " I'll , I I'll "P" - � �,/,,11 ... I), ­ � �­ V111-11111111 -I I .�, 0 W W ()o co 1,� ,I. ,,, I �;,',111111 �11 111- - ��� ,, �111111", , _p - 1-11,111-1- -_ .0 � . � �7 I -1_11 � ,.. 11 'I . -4 s I I , 11 - F Z T- co N C) DEMOLITION - CEI . L - W 0') N .1 0 0 -r < 0') . � ,OCT, 043 2017, 3: d 2 �- ) - -� z I W 0- _j . . .., - . � " . - :, - , . . I . , . . I .� . -�l W 3: W 0 I , , - , (3) Ill- v W c,r) D < I "I'll".., I v - F_ 0 - 1, , I ,zj, I'' I '' '' 11 I'll 1 1111_ I qm DATE I ISSUE 07.2016 --Fp- ERmIT SET VINIM1,11, 111111"imm PHOTO DEMOLITION - SERVING COUNTER SCALE: NONE ERMIT CEINTER AD -2.1 2016-11-00 KITCHEN EQUIPMENT SCHEDULE SCALE: NTS EQUIPMENT SCHEDULE r r REMARKS RESP QTY. SIZE,(WxHxD) (inches) MANUFACTURER MODEL NO. DESCRIPTION ITEM SIZE (wxdxh) (inches) ER 2 1..4.37'x11.92`x14,29" PROTECH PS -6509 P.O.S (CASH REGISTER) 781/8"x293/4"x783/8" EXISTING EXISTING REACH -IN REFRIGERATOR 5 ER 1 39NWN44" R1 NSE654AS-1B ER 2 16.2"x16.4"x4.3" MMF SP -103 P.O.S. Cash Drawer B-0592 POT FILLER 13 E 1 541/8"x293/4"x783/8" EXISTING EXISTING RIA 14 BO 2 5.71 "x 7.68"x 5.83" EPSON TMT881V P.O.S. Printer 15 E 1 42"x20"x36" HOBART FP100 FOOD PROCESSOR 16 R2 1 BO 2 59 1/2"x23 5/8"x9 3/4" DELFEELD N8800-SPL4-PAN BAIN MARIE WARMER. 1 12°x17" GSW HS-1217SS WALL -MOUNTED HAND SINK 18 E 1 R3 ADJUSTABLE ANGLE BRACKETS; REMOTE CONTROL ENCLOSURE RMB -70; HALOGEN BULBS BO 2 54"x9''x2.5" HATCO GRAIHL-54 INFRA BLACK STRIP HEATER CAPTIVEAIRE COUNTERTOP WARMER KITCHENHOOD W/ANSULSYSTEM 28 KEY: E: Existing- no change :S: Salvage- turnover to Owner R4 R20 BO 1 8.6"x18.9"x17.8" BUNN POUROVER COFFEE BREWER BO 1 71 112'x23 518''x9 314" DELFEELD N8800 -SPL -5 -PAN BAIN MARES WARMER, R21 QUICK DISCONNECT (GAS CONNECTOR R5 ADJUSTABLE ANGLE BRACKETS; REMOTE ( 3/4"diax48" LONG) BO 1 18"x20"x32.5" AMERICAN RANGE ARWR-3R CONTROL ENCLOSURE RMB -70; HALOGEN BULBS BO 1 42'x9"x2.5'' HATCO GRAIHL-36 INFRA BLACK STRIP- HEATER RS ADJUSTABLE ANGLE BRACKETS; REMOTE ( 3/4"diax48" LONG) BO 38"x44.5"x57.5" GARLAND MCO GD -10-S CONTROL ENCLOSURE RMB -70; HALOGEN BULBS BO 1 36"x9"x2.5" HATCO GRAIHL-30 INFRA BLACK STRIP HEATER. R6..1 { 3/4"diax48" LONG) BO 1 36"07"X42" CLEVELAND RANGE SGL30TR BRAISING PAN 30 gal BO 1 15.75"x 15.5"x 9" METTILER TOLEDO UC -ST COUNTER SCALE E62083D100 STEAMER R7 M22 BO 1 T&S B-0205LN/133X SWIVAL DUAL CONTROL FAUCET BO 1 30"x 12"x 1" 30"x12"x1" E2436 POLYBOARD jj23 W/ T&S B -0133-B PRE -RINSE, B-155LNM ADD-ON 1 -ER, R8 FAUCET, AND 068X FAUCET PART 1 -BO 2 25 9/16"x20 3/4"x 18 9/16" PANASONIC NE -3280 MICROWAVE BO 3 BO T&S B-0205LN/OCS8 SWNAL DUEL. CONTROL FAUCET CUSTOM S/S TABLE R9 CONNECT IT (QUICK DISCONNECT) M25 STRAPPED TO ADJACENT HALF -HEIGHT WALL E ( 3/4"diax48" LONG); CONNECTING STREP BO 3 15 5/8"X31 1/2"X46" FRYMASTER MJ45-SD FRYER R10 WATER HEATER 26 E BO 1 23"x 28.5"x 15" CASTLE 2923SF FLAT FRYER KITCHENHOOD W/ ANSUL SYSTEM 28 11/1 NEW ER 1 12 1/2"x17 114"x13 3/8" GSW HS1217SSG HAND SINK 5430ND-2-PSP-F KITCHENHOOD W/ ANSUL SYSTEM M29 R12 BO BO 1 27 518"x30 1/8"x29 3/4" TRUE TUC -27G -ADA UNDER COUNTER REFRIDGERATOR TRAY RAIL R30 KEY: E: Existing- no change ER: Existing to be relocated BO: By Owner R 13 ER 1 15" dia x 16" ZOJIRUSHI THA -803 RICE WARMER. R,#4 BO 1 7" dia x 5 1/2" GSW HS-DSRO DIPPER WELL R15 KITCHEN EQUIPMENT SCHEDULE SCALE: NTS NOTE: KITCHEN EQUIPMENT IS SHOWN FOR REFERENCE ONLY. ALL MEP WORK TO BE FILED AS A DEFFERED SUBMITTAL AND SUBMITTED SEPARATELY FROM THIS DRAWING SET. FUTURE TENANT TO APPLY FOR HEALTH DEPT. PERMIT. NOTE: CONTRACTOR SHALL COORDIANTE ANC FIELD VERIFY EXISTING EQUIPMENT VS, NEW EQUIPMENT FURNISH AND INSTALL NEW EQUIPMEW THAT IS NOT SALVAGABLE EQUIPMENT SCHEDULE r r _a) REMARKS RESP QTY. EQUIPMENT (ALREADY INSTALLED) MANUFACTURER RESP CITY. SIZE (wxdxh) (inches) MANUFACTURER MODELNO. DESCRIPTION ITEM E 1 781/8"x293/4"x783/8" EXISTING EXISTING REACH -IN REFRIGERATOR 5 ER 1 39NWN44" SCOTSMAN NSE654AS-1B ICE MAKER W/ BIN 10 S 1 33/16"x209/16"x6" T&S BRASS B-0592 POT FILLER 13 E 1 541/8"x293/4"x783/8" EXISTING EXISTING REACH -IN FREEZER 14 E 1 72"x24"06" GC CUSTOM PREP TABLE AND SINK 15 E 1 42"x20"x36" HOBART FP100 FOOD PROCESSOR 16 E 1 24N90 3/4"x45" EXISTING EXISTING 3 -COMPARTMENT SINK 17 E 1 12°x17" GSW HS-1217SS WALL -MOUNTED HAND SINK 18 E 1 2411x24" EXISTING EXISTING 24X24MOPSINK. 19 E 1 FIELD MEASURE CAPTIVEAIRE COUNTERTOP WARMER KITCHENHOOD W/ANSULSYSTEM 28 KEY: E: Existing- no change :S: Salvage- turnover to Owner ER: Existing- to be relocated NOTE: KITCHEN EQUIPMENT IS SHOWN FOR REFERENCE ONLY. ALL MEP WORK TO BE FILED AS A DEFFERED SUBMITTAL AND SUBMITTED SEPARATELY FROM THIS DRAWING SET. FUTURE TENANT TO APPLY FOR HEALTH DEPT. PERMIT. NOTE: CONTRACTOR SHALL COORDIANTE ANC FIELD VERIFY EXISTING EQUIPMENT VS, NEW EQUIPMENT FURNISH AND INSTALL NEW EQUIPMEW THAT IS NOT SALVAGABLE STALL NEW FLOOR SINKS- DORD. EXACT LOCATION 'ITH NEW KITCHEN EQUIP. RE SEWED FOR �ODgppROVED CE AUG 2 9 2016 City of Tukwila BUILDING DIVISION N �$ x kz - daYTa i2MY.Y.W .00T. 032917, y RECEIVED CITU' OF TUKWILA JUL 2 8 2016 PERMIT CENTER I SCALE: NTS N EQUIPMENT SCHEDULE r r _a) REMARKS RESP QTY. SIZE (WxHxD) (inches) MANUFACTURER MODEL NO. DESCRIPTION ITEM ' rn N a� N U>N Q Q 0 0 0 u) CO o C N N ER 1 49 1/8"x23 718"x35 5/8" TRUE TBB-24-48G-SD CHILLER, GLASS DOOR SLIDER n J —I O R16 BO 2 11 1/4"05 7/8"x27 1/4" CRATHCO-GRINDMASTER E294 BEVERAGE DISPENSER w�� z z o0 W R17 DIMENSIONA ARE FOR GENERIS SCREEN rn = � ASO O) VERIFY ACTUAL BO 3 48.78"x28.46"x2.99" HS-1217SS 55" LED TV MENU BOARD R18 BO 1 18 5/8" x 9 7/8x10 3/8' NEMCO VP17-2 COUNTERTOP WARMER R20 BO 1 8.6"x18.9"x17.8" BUNN POUROVER COFFEE BREWER R21 QUICK DISCONNECT (GAS CONNECTOR ( 3/4"diax48" LONG) BO 1 18"x20"x32.5" AMERICAN RANGE ARWR-3R HEAVY DUTY WOK RANGE M19 QUICK DISCONNECT (GAS CONNECTOR) ( 3/4"diax48" LONG) BO 38"x44.5"x57.5" GARLAND MCO GD -10-S MINI OVEN M20 QUICK DISCONNECT (GAS CONNECTOR) { 3/4"diax48" LONG) BO 1 36"07"X42" CLEVELAND RANGE SGL30TR BRAISING PAN 30 gal M21 BO 1 23.19X26.55x25.36 ACCUTEMP E62083D100 STEAMER M22 BO 1 T&S B-0205LN/133X SWIVAL DUAL CONTROL FAUCET jj23 W/ T&S B -0133-B PRE -RINSE, B-155LNM ADD-ON 1 -ER, FAUCET, AND 068X FAUCET PART 1 -BO 2 25 9/16"x20 3/4"x 18 9/16" PANASONIC NE -3280 MICROWAVE M24 BO 1 48"x30"x36" GC CUSTOM S/S TABLE M25 STRAPPED TO ADJACENT HALF -HEIGHT WALL E 1 2' DIA. EXISTING EXISTING WATER HEATER 26 E 1 FIELD MEASURE CAPTIVEAIRE KITCHENHOOD W/ ANSUL SYSTEM 28 NEW 1 FIELD MEASURE CAPTIVEAIRE 5430ND-2-PSP-F KITCHENHOOD W/ ANSUL SYSTEM M29 BO 1 FIELD MEASURE TRAY RAIL R30 KEY: E: Existing- no change ER: Existing to be relocated BO: By Owner S; Salvage- turnover to Owner STALL NEW FLOOR SINKS- DORD. EXACT LOCATION 'ITH NEW KITCHEN EQUIP. RE SEWED FOR �ODgppROVED CE AUG 2 9 2016 City of Tukwila BUILDING DIVISION N �$ x kz - daYTa i2MY.Y.W .00T. 032917, y RECEIVED CITU' OF TUKWILA JUL 2 8 2016 PERMIT CENTER I SCALE: NTS N r r _a) a)0 � C U Co L L 0 ca -a CO o ' rn N a� N U>N Q Q 0 0 0 u) CO o C N N cu 3LoCn tea) 01-20.zc�1(0 z n z W n J —I O O O i W w�� z z o0 W WAN U Q rn = � ASO O) W U C'e)�Q DATE ISSUE 07.20.16 PERMIT SET A-2.2 2016-11-00 EXISTING CONCRETE SLAB 2'-0" MAX. NEW CONCRETE SLAB NEW REBAR TO MATCH F'c = 4500 PSI EXISTING BAR AND SPACING d p ,4 ' O d 4,140. d O p. QI 4. 0)p 4 p' O d. O O p v.' O 2" SPLICE WITH LENTON® LOCK - STAGGER THE CONNECTION EXISTING SLAB CUT AND INFILL 6 SCALE: 1.1/2" = 1'-0" EXISTING CONCRETE SLAB 2'-0" MAX. DOWEL INTO EXISTING SLAB FOR 4'-0" x 4'-0" (3- #4 DWL) p N :d d 4 p 4 d d 4. 0') v 4 v c 4- d. Q NEW CONCRETE SLAB F'c = 4500 PSI EXISTING SLAB CUT AND INFILL AT DOWEL 3 SCALE: 1.1/2" = 1'-0" 4 4 4'-0.". MAX: O v v CUT:Ol1T 2'=0" X 2'-0" dC d v p CONCRETE, CUT EXISTING p REBAR AT CHIPPED. ` p d4 d d p cil. CUT EXISTING REBAR IF NOT WITHIN CHIPPED Q OUT.AREA AREA).. d d p O I 4 ° d p TW 1 v -.4 ° a . 0 W L.L_ J Q aLJ. � O d opp p Q W r' � N N = U <C rn M� ry ASO d ° d O d O 4 p U MQ p d' F— d G p d ad —.NEW REBAR TO d ° v . . MATCH EXISTING. . a ° d 4 , BAR AND SPACING; v d ° d p 4 .. „'d d p 4 ° p ° d d NEW CONCRETE 4 SLAB F'c :=4500 PSI d .4- 4 d•d 4 SPLICE WITH v ° LENTON® LOCK . STAGGER THE v 'CONNECTIO.N d 4 q v c 4EXISTING CONCRETE SLAB 4 p d :d p • p 4 p. d EXISTING -SPACING. EXISTING SLAB CUT �AN�Dl FILL � \ 1'-0" EXISTING CONCRETE SLAB 2'-0" MAX. NEW CONCRETE SLAB NEW REBAR TO MATCH F'c = 4500 PSI EXISTING BAR AND SPACING d p ,4 ' O d 4,140. d O p. QI 4. 0)p 4 p' O d. O O p v.' O 2" SPLICE WITH LENTON® LOCK - STAGGER THE CONNECTION EXISTING SLAB CUT AND INFILL 6 SCALE: 1.1/2" = 1'-0" EXISTING CONCRETE SLAB 2'-0" MAX. DOWEL INTO EXISTING SLAB FOR 4'-0" x 4'-0" (3- #4 DWL) p N :d d 4 p 4 d d 4. 0') v 4 v c 4- d. Q NEW CONCRETE SLAB F'c = 4500 PSI EXISTING SLAB CUT AND INFILL AT DOWEL 3 SCALE: 1.1/2" = 1'-0" 4 4 4 - #4 X V-6" TOP/BOTTOM EACH WAY - REBAR TYP SCALE: 1.1/2" = 1'-0" SECTION - NEW SLAB / FLOOR SINK v SCALE: 1.1/2" = 1'-0" Ce) N 2 DOOR DETAIL SCALE. 1 1 0 TYPE "X" 3UM WALL RD ON MTL )S )D BLOCKING ICAL AT JAMB) -OW METAL )IE HORS (TYPICAL) - =E PER JAMB \IUM V METAL DOOR ,R FINISH DER 'HEDULE REVIEWED FOR CODE COMPLIANCE APPROVED AUG 2 9 2016 v City of Tukwila BUILDING DIVISION HARDWARE SETS HARDWARE SET #1 (SERVICE AREA, 60 MINUTE RATED) MORTISE "L" SERIES LOCKSET (PROVIDE CONSTRUCTION CORE) 1 1/2 PAIR BUTT HINGES SMOKE SEALS CLOSER THRESHOLD HARDWARE SET #2 (STORAGE) MORTISE "L" SERIES LOCKSET (PROVIDE CONSTRUCTION CORE) 1 1/2 PAIR BUTT HINGES CLOSERS SILENCERS THRESHOLD GENERAL NOTES 1. ALL EXIT DOORS SHALL BE OPERABLE WITHOUT THE USE OF KEYS, SPECIAL KNOWLEDGE, OR EFFORT. 2. ALL DOORS SHALL HAVE A MINIMUM CLEAR OPENING WIDTH OF 32". 3. ALL DOOR LATCHES SHALL BE EQUIPPED WITH LEVER -TYPE HANDLES. DOOR OPENING HARDWARE SHALL BE MOUNTED BETWEEN 30" AND 44" ABOVE FINISH FLOOR. 4. FLOOR AREAS AT EACH SIDE OF ALL DOORS SHALL BE CLEAR AND LEVEL. MAXIMUM THRESHOLD HEIGHT SHALL BE 1/2". N o OCT. 03 2017, 2" .. 3'-0" S/S KICK PLATE 101 1 HOUR DOOR ff RECEIVED INTERIOR D90��194' THLVWILA FRAME: HOLLOW J�(I�T'h 2016 WELDED JdJ� DOOR: MTL. HOLLOW CORE PERnrwr CEIUT'ER _ HARDWARE SET #2 U) O v v CUT:Ol1T 2'=0" X 2'-0" dC d FROM EXISTING . p CONCRETE, CUT EXISTING REBAR AT CHIPPED. ` 0 OUT AREA (DO NOT cil. CUT EXISTING REBAR IF NOT WITHIN CHIPPED Q OUT.AREA AREA).. vJ W O 4 - #4 X V-6" TOP/BOTTOM EACH WAY - REBAR TYP SCALE: 1.1/2" = 1'-0" SECTION - NEW SLAB / FLOOR SINK v SCALE: 1.1/2" = 1'-0" Ce) N 2 DOOR DETAIL SCALE. 1 1 0 TYPE "X" 3UM WALL RD ON MTL )S )D BLOCKING ICAL AT JAMB) -OW METAL )IE HORS (TYPICAL) - =E PER JAMB \IUM V METAL DOOR ,R FINISH DER 'HEDULE REVIEWED FOR CODE COMPLIANCE APPROVED AUG 2 9 2016 v City of Tukwila BUILDING DIVISION HARDWARE SETS HARDWARE SET #1 (SERVICE AREA, 60 MINUTE RATED) MORTISE "L" SERIES LOCKSET (PROVIDE CONSTRUCTION CORE) 1 1/2 PAIR BUTT HINGES SMOKE SEALS CLOSER THRESHOLD HARDWARE SET #2 (STORAGE) MORTISE "L" SERIES LOCKSET (PROVIDE CONSTRUCTION CORE) 1 1/2 PAIR BUTT HINGES CLOSERS SILENCERS THRESHOLD GENERAL NOTES 1. ALL EXIT DOORS SHALL BE OPERABLE WITHOUT THE USE OF KEYS, SPECIAL KNOWLEDGE, OR EFFORT. 2. ALL DOORS SHALL HAVE A MINIMUM CLEAR OPENING WIDTH OF 32". 3. ALL DOOR LATCHES SHALL BE EQUIPPED WITH LEVER -TYPE HANDLES. DOOR OPENING HARDWARE SHALL BE MOUNTED BETWEEN 30" AND 44" ABOVE FINISH FLOOR. 4. FLOOR AREAS AT EACH SIDE OF ALL DOORS SHALL BE CLEAR AND LEVEL. MAXIMUM THRESHOLD HEIGHT SHALL BE 1/2". N o OCT. 03 2017, 2" .. 3'-0" S/S KICK PLATE 101 1 HOUR DOOR ff RECEIVED INTERIOR D90��194' THLVWILA FRAME: HOLLOW J�(I�T'h 2016 WELDED JdJ� DOOR: MTL. HOLLOW CORE PERnrwr CEIUT'ER _ HARDWARE SET #2 U) v • a° • dC d • p d d4 v 0 4 - #4 X V-6" TOP/BOTTOM EACH WAY - REBAR TYP SCALE: 1.1/2" = 1'-0" SECTION - NEW SLAB / FLOOR SINK v SCALE: 1.1/2" = 1'-0" Ce) N 2 DOOR DETAIL SCALE. 1 1 0 TYPE "X" 3UM WALL RD ON MTL )S )D BLOCKING ICAL AT JAMB) -OW METAL )IE HORS (TYPICAL) - =E PER JAMB \IUM V METAL DOOR ,R FINISH DER 'HEDULE REVIEWED FOR CODE COMPLIANCE APPROVED AUG 2 9 2016 v City of Tukwila BUILDING DIVISION HARDWARE SETS HARDWARE SET #1 (SERVICE AREA, 60 MINUTE RATED) MORTISE "L" SERIES LOCKSET (PROVIDE CONSTRUCTION CORE) 1 1/2 PAIR BUTT HINGES SMOKE SEALS CLOSER THRESHOLD HARDWARE SET #2 (STORAGE) MORTISE "L" SERIES LOCKSET (PROVIDE CONSTRUCTION CORE) 1 1/2 PAIR BUTT HINGES CLOSERS SILENCERS THRESHOLD GENERAL NOTES 1. ALL EXIT DOORS SHALL BE OPERABLE WITHOUT THE USE OF KEYS, SPECIAL KNOWLEDGE, OR EFFORT. 2. ALL DOORS SHALL HAVE A MINIMUM CLEAR OPENING WIDTH OF 32". 3. ALL DOOR LATCHES SHALL BE EQUIPPED WITH LEVER -TYPE HANDLES. DOOR OPENING HARDWARE SHALL BE MOUNTED BETWEEN 30" AND 44" ABOVE FINISH FLOOR. 4. FLOOR AREAS AT EACH SIDE OF ALL DOORS SHALL BE CLEAR AND LEVEL. MAXIMUM THRESHOLD HEIGHT SHALL BE 1/2". N o OCT. 03 2017, 2" .. 3'-0" S/S KICK PLATE 101 1 HOUR DOOR ff RECEIVED INTERIOR D90��194' THLVWILA FRAME: HOLLOW J�(I�T'h 2016 WELDED JdJ� DOOR: MTL. HOLLOW CORE PERnrwr CEIUT'ER _ HARDWARE SET #2 U) dC W 0 z Q vJ W I D TW 1 U 0 W L.L_ J Q � O W opp O qt Q W r' � N N = U <C rn M� ry ASO Z O oma_-' O U)'S U MQ ry T_ F— n DATE ISSUE 07.20.16 PERMIT SET A-2.4 2016-11-00 CEILING SCHEDULE NO. MANUFACTURER DESCRIPTION MATERIAL FINISH REMARKS C1 GOLD BOND DRYWALL CEILING ON 5/8" TYPE "X" GYPSUM FORMICA LAMINATE CONFIRM HEIGHTS AND ASCE-7-05 SECTION 13.5.6.2.2, ITEM B. METAL FRAMING BOARD EBONY (9012) MATERIALS OF EXISTING SUPPORTING THE ROOF OR FLOOR ABOVE. GOLD BOND DRYWALL CEILING ON 5/8" TYPE "X" GYPSUM PAINT DUNN EDWA RDS CEILING COMPONENTS RIVETS ARE ACCEPTABLE. ON THE OTHER METAL FRAMING BOARD PEARL WHITE (DEW 328) PATCH AND REPAINT C2 SUSPENDED CEILING SYSTEM TO COMPLY WITH 17 CLEARANCE BETWEEN THE ENDS OF THE SEMI -GLOSS EXISTING CEILING TO MATCH COLORS AND GOLD BOND DRYWALL CEILING ON 5/8" TYPE "X" GYPSUM PAINTGLIDDEN SECTION 13.5.6.2.2, ITEM B. SEPARATION JOINTS OF FULL HEIGHT METAL FRAMING BOARD RED GERANIUM (GLR06) FINISHES LISTED IN THIS C3 A 3/4" CLEARANCE BETWEEN THE ENDS OF INTO AREAS NOT EXCEEDING 2,500 SF. SEMI -GLOSS TABLE. THE GRID AND THE WALL. REFERENCE GOLD BOND DRYWALL CEILING ON 5/8" TYPE "X" GYPSUM PAINT: BEHR C4 4. CISCA RECOMMENDATIONS FOR SEISMIC METALFRAMING BOARD BILLOWY DOWN (7803-1) ZONES 3-4. (CEILINGS AND INTERIOR PREVENT THE SPREAD OF MAIN BEAMS 2'X 4' SUSPENDED T -BAR "VINYL ROCK" VINYL - CLAD WHITE AND/OR CROSS TEES. CISCA GUIDELINES C5 USG GRID CEILING SYSTEM GYP. BD. PANELS SMOOTH & WASHABLE SPECIFIC CASE, DIFFERENT SECTIONS OF SUSPENDED CEILING ASSEMBLIES, SEISMIC ALLOW FOR FREE MOVEMENT OF AT LEAST 1" THIS CODE SPECIFY DIFFERENT MATERIALS, ,. ZONES 3 & 4, MAY, 2004, INSTALLATION ELECTRICAL FIXTURE LEGEND SYMBOL DESCRIPTION LAMP X WATTS REMARKS 2'X 4' FLUORESCENT LIGHT 32W TS, 48" W/ SHATTER -PROOF LENS HIGH EFFICIANCYT8TROFFER -STATIC T8, 120/277V BY: "LSI", PETROLEUM LIGHTING, 50/60HZ GA332SDSS010EM12OLMP841 LMP841 DOWNLIGHT, RECESSED COMPACT FLUORESCENT MATCH EXIST. FIXTURES W/ SHATTER -PROOF LENS @ KITCHEN, PREP AREA, & SERVICE AREA DOWNLIGHT, RECESSED COMPACT FLUORESCENT MATCH EXIST. FIXTURES W/ SHATTER -PROOF LENS @ KITCHEN, PREP AREA, & SERVICE AREA PENDANT LIGHT MATCH EXIST.I U F XT RES O° LIGHTING MATCH EXIST. o v v v 1, s CEILING MOUNTED EMERGENCY LIGHT 25 W LIGHT TO PROVIDE AN AVERAGE 1 TWO HEADS W/ 90 MIN. BATTERY PACK ILLUMINATION OF 1 FOOTCANDLE BUT NOT 120V, WHITE COLOR LESS THAN 0.1 FOOTCANDLE AT ANY POINT ALONG PATH OF EGRESS AT FLOOR LEVEL UNIVERSAL MOUNTED EXIT SIGN X 7 W CLEAR FLEXI FLUORESCENT, 120V W/ 90 MIN. BATTERY PACK. SINGLE FACE GREEN LETTERING EXISTING LIGHTTO REMAIN IN PLACE ENSURE LIGHT IS OPERABLE. REPLACE IF NECESSARYTO MATCH EXISTING ADJACENT FIXTURES f.. SEISMIC SUPPORT FOR CEILING SYSTEM: b. WIDTH OF THE PERIMETER SUPPORTING PODS AT 12'-0" MAX. O.C. AND 6'-0" MAX. FROM N =3 E CLOSURE ANGLE (WALL ANGLE) SHALL NOT WALLS. A STRUT FASTENED TO THE MAIN ARMSTRONG SEISMIC RX SUSPENSION SYSTEM BE LESS THAN 2.0 INCHES. REFERENCE RUNNER SHALL BE EXTENDED TO AND ICC -ESR -1308 USED AS BASIS OF DESIGN. ASCE-7-05 SECTION 13.5.6.2.2, ITEM B. FASTENED TO THE STRUCTURAL MEMBERS t10 3: a7 N c. ON TWO ADJACENT SIDES, THE GRID SHALL SUPPORTING THE ROOF OR FLOOR ABOVE. SUBSTITUTIONS PERMITTED PROVIDED THEY BE ATTACHED TO THE WALL ANGLE. POP CISCA GUIDELINES FOR SEISMIC RESTRAINT COMPLY WITH ASTM C636 AND ASTM E580 RIVETS ARE ACCEPTABLE. ON THE OTHER FOR DIRECT HUNG SUSPENDED CEILING 0")O N TWO SIDES, THERE SHALL BE A 3/4" ASSEMBLIES, SEISMIC ZONES 3 & 4, MAY, SUSPENDED CEILING SYSTEM TO COMPLY WITH 17 CLEARANCE BETWEEN THE ENDS OF THE 2004, INSTALLATION SECTION, ITEM 3. THE FOLLOWING CODES AND REGULATIONS: GRID AND THE WALL. REFERENCE ASCE-7-05 i. CEILINGS OVER 2,500 SF MUST HAVE SEISMIC SECTION 13.5.6.2.2, ITEM B. SEPARATION JOINTS OF FULL HEIGHT 1. 2012 INTERNATIONAL BUILDING CODE (IBC) d. ON THE OTHER TWO SIDES, THERE SHALL BE PARTITION THAT BREAKS THE CEILING UP SECTIONS 808 AND 1613.1 A 3/4" CLEARANCE BETWEEN THE ENDS OF INTO AREAS NOT EXCEEDING 2,500 SF. 2. ASTM C635 AND ASTM C636. < THE GRID AND THE WALL. REFERENCE REFERENCE ASCE-7-05 SECTION 13.5.6.2.2, 3. ASCE-7-05 SECTION 13.5.6.2.2. DATE ISSUE ASCE-7-05 SECTION 13.5.6.2.2, ITEM B. ITEM E. 4. CISCA RECOMMENDATIONS FOR SEISMIC e. STABILIZER BARS ARE REQUIRED TO j. FOR CEILINGS WITHOUT REIGID BRACING, ZONES 3-4. (CEILINGS AND INTERIOR PREVENT THE SPREAD OF MAIN BEAMS SPRINKLER HEAD AND OTHER PENETRATIONS SYSTEMS CONSTRUCTION ASSOCIATION). AND/OR CROSS TEES. CISCA GUIDELINES SHALL HAVE A 2" OVERSIZE RING, SLEEVE, OR 5. IBC 102.1, WHICH STATES, "WHERE, IN ANY FOR SEISMIC RESTRAINT FOR DIRECT HUNG ADAPTER THROUGH THE CEILING TILE TO SPECIFIC CASE, DIFFERENT SECTIONS OF SUSPENDED CEILING ASSEMBLIES, SEISMIC ALLOW FOR FREE MOVEMENT OF AT LEAST 1" THIS CODE SPECIFY DIFFERENT MATERIALS, ZONES 3 & 4, MAY, 2004, INSTALLATION IN ALL HORIZONTAL DIRECTIONS; OR, METHODS OF CONSTRUCTION OR OTHER SECTION ITEM 4. SPRINKLER HEAD EXTENSION TO HAVE REQUIREMENTS THE MOST RESTRICTIVE f.ERI P METER SUPPORT (TAIL) WIRES ARE SWING JOINT THAT CAN ACCOMMODATE 1 OF SHALL GOVERN. WHERE THERE IS A REQUIRED WITHIN 8" OF THE WALL FOR ALL CEILING MOVEMENT IN ALL DIRECTIONS. CONFLICT BETWEEN A GENERAL EDGES. CISCA GUIDELINES FOR SEISMIC REFERENCE ASCE-7-05 SECTION 13.5.6.2.2, REQUIREMENT AND A SPECIFIC RESTRAINT FOR DIRECT HUNG SUSPENDED ITEM E. REQUIREMENT, THE SPECIFIC CEILING ASSEMBLIES, SEISMIC ZONES 3 & 4, k. CHANGES IN CEILING PLAN ELEVATION SHALL REQUIREMENTS SHALL BE APPLICABLE". MAY, 2004, INSTALLATION SECTION, ITEM 2. BE PROVIDED WITH POSITIVE BRACING. 6. NOTE THAT THE SUSPENDED CEILING g. VERTICAL HANGERS SHALL BE NO. 12 GAUGE REFERENCE ASCE-7-05 SECTION 13.5.6.2.2, SYSTEM MUST MEET THE FOLLOWING WIRE SPACED AT 4'-0" O.C. ALONG EACH MAIN ITEM F. REQUIREMENTS: RUNNER. THREE WIRE TURNS REQUIRED. I. CABLE TRAYS AND ELECTRICAL CONDUITS a. ONLY HEAVY DUTY T -BAR GRID SYSTEM WITHIN 1:6 OUT -OF -PLUMB UNLESS SHALL BE SUPPORTED INDEPENDENTLY OF SHALL BE USED. REFERENCE ASCE-7-05 COUNTER -SLOPING WIRES ARE PROVIDED. THE CEILING. REFERENCE ASCE-7-05 SECTION 13.5.6.2.2, ITEM A. h. LATERAL BRACING IS REQUIRED: SPLAY WIRE SECTION 13.5.6.2.2, ITEM G. LAY -IN CEILING - SEISMIC DETAILS SCALE: N.T.S. conip i post - 12 Ga.. i(aRgerwire Typ.41-0' G,Q (3'TIght IF+t apsi Main Beam A :d 0rx s Tees L T..f d _,✓ OSEISMIC SUPPORT BRACING C5 10'-0" . SD "IST, y.� 1 . E , s . .................. .................. .... ...... OCT 0a217, 12 Ga, GRIDS ATTACHED TO WALL ANGLE ON TWO ADJACENT SIDES. PROVIDE 3/4" CLEARANCE BETWEEN ENDS OF GRID AND WALL ON THE OTHER TWO SIDES. ,tI REVIEWED FOR ODE COMPLIAW APPROVED AUG 2 9 2016 Ub FLEXIBLE BRACKET AT ATTACHED AL1,Cij�tifTukwila 4 BI III DING DIV SII -------------_........................................ _.......------....---------------................................................................................. . ..>:*`:....................................... E ...... ......... .. ' ... -- 1 (E) LIGHTS AND CEILING TO REMAIN. SCALE: 1/4" = V-0" F CONFIRM ALL LIGHT FIXTURES ARE FUNCTIONING AND REPLACE WITH LIKE KIND AS NECESSARY. PATCH AND REPAIR ALL SURFACES AND REPAINT PER COLORS LISTED IN 1/A-3.1. ® FACING TOWARD FRONT OF SPACE U FACING TOWARD REAR OF SPACE (E) CEILING CONDITION PHOTOS SCALE: N.T.S. W U W F_ U W J H W TUKWILA 19 2015 I' CENTER N J N =3 E W O coU d o co c:ao co t10 3: a7 N C N 0 1- ON L •— Q Q N U) U) co co r- C) � N N In W 0- N J J Q O O WoOO~ N� LU 0")O N UQ� 17 3:O �Qz 0 SSU M < �-- n DATE ISSUE 07.20.16 PERMIT SET 08.17.16 A REVISIONS A-3.1 2016-11-00 INTERIOR ELEVATION - STOREFRONT SCALE: NTS INFILL GAP ut- XI TIN CEILING EXHAU 55" TV 55" TV HOOD MENU MENU EXIST. TO DOORWAY (4) SIDES OF OPEN BEYOND PREP AREA o COLUMN NEW HALF WALL CABINETRY BY OWNER 55" TV MENU OPEN TO PREP AREA INTERIOR ELEVATION - FRONT COUNTER - FRONT SCALE: 1/4" = V-0" REPLACE TOYKO SIGN WITH NEW CRISPY TOWN SIGNAGE IA - (4) SIDES OF COLUMN ni i INTERIOR ELEVATION - NORTH VIEW WITH PART -HI WALL Cr'AI C- 4/A" - 4'_n" t CHOW KING DINING AREA BEYOND AREA NOT IN SCOPE r i " u AREA NOT IN SCOPE KEY PLAN SCALE: NONE I EXIS T. ELEVATOR ■�■I I■NEI I■a■� a ,;Pr ' � IAIi � � ■i ■�■ lit �■I ; �?�,I 119 �© — -- —,— -- —�■ it■'II ii■1 Il( ■■ ■I■ ■■ — -- Ron i IAII 131 i! imam I I■ ■I 1■■' 1 -mi 1 • PATCH COLUMN FINISH AT NEW WALL INTERSECTION 1' t NEW — DOOR AND FRAME P TC COLUMN FINIS11i AT DOOR NEW FRONT COUNTER DROP CEILING TO 10'-0" AT NEW KITCHEN HOOD AND INFILL 6" GAP TO TOP OF HOOD �T� `CUT qACK SOFFIT WALL T EXHAUS/T- HOOD F (E) STAINLESS STEEL CALDDING ® TO BE REUSED IN THESE AREAS MOVE OLD ADHESIVE AND PRE.P ADJACENT WALL AREA FOR NEW FRP APPLICATION PAINT SCHEDULE NO. I MANUFACTURER MFG#1 COLOR FINISH REMARKS PT -01 FRAZEE COLOR LIFE CL2771W ARROWROOT EGG -SHELL CRISPYTOWN BRANDING COLOR; WALL/SOFFIT PT -02 FRAZEE COLOR LIFE CL2773M TOFFEE EGG -SHELL CRISPY TOWN STD COLOR; WALL/SOFFIT PT -03 FRAZEE COLOR LIFE CL2775D VENISON EGG -SHELL CRISPY TOWN STD COLOR; WALL/SOFFIT PT -04 FRAZEE COLOR LIFE CL1835D SLAM EGG -SHELL CRISPY TOWN STD COLOR; WALL/SOFFIT PT -05 FRAZEE COLOR LIFE CL1626N FRENCH NARROW EGG -SHELL CRISPY TOWN STD COLOR; WALL/SOFFIT PT -06 FRAZEE COLOR LIFE CL1953D WEEDEN EGG -SHELL CRISPY TOWN STD COLOR; WALL/SOFFIT NOTE: CONTRACTOR TO VERIFY SCHEDULED PAINT COLORS AND FINISHES AS A MATCH WITH EXISTING AND TO FURNISH NEW PAINT WHERE COLOR CHANGED ANY REMAINING ORIGINAL, UNDAMAGED MATERIALS ARE TO REMAIN IN PLACE AND BE REUSED THROUGHOUT. ,sae QCT. 03 2,17, INTERIOR ELEVATION - NORTH VIEW - NORTH SIDE WALL 0 4)MI 1'-0" N r WALL / LAMINATE SCHEDULE NO. MANUFACTURER DESCRIPTION MFG# COLOR/FINISH REMARKS WP -01 ROSEBURG DURAMINE LAMINATE 55 HARD ROCK MAPLE WP -02 AMERICAN LAMINATES ACCENT MATERIAL 9012 FUSION MAPLE WP -03 ROSEBURG DURAMINE WAINSCOT 78 WINDSOR MAHOGANY WP -04 ROSEBURG DURAMINE LAMINATE 64 PEARWOOD WF -01 MARLITE FRP P100 WHITE WF -02 S/S FABRICATOR S/S PANEL (22 GA.) BEHIND COOKING LINE aD 0 `j N cu cq cu 5 Lo cn ii 0'' 5-01 COLORED GLASS RED PAINT BEHIND PORTAL S-02 �� WOOD VENEER STRIPS PORTAL 1- O -W 1 NOTE: CONTRACTOR TO VERIFY SCHEDULED PAINT COLORS AND FINISHES AS A MATCH WITH EXISTING AND TO FURNISH NEW PAINT WHERE COLOR CHANGED ANY REMAINING ORIGINAL, UNDAMAGED MATERIALS ARE TO REMAIN IN PLACE AND BE REUSED THROUGHOUT. ,sae QCT. 03 2,17, INTERIOR ELEVATION - NORTH VIEW - NORTH SIDE WALL 0 4)MI 1'-0" N r z a) =3 E c 0 I— J J cu `' U Q C co W cu j 0) V N W N oQ cu E U CL N U Q N N aD 0 `j N cu cq cu 5 Lo cn ii 0'' Uj: 20. Z0 14P V! z O I— J J Q W O O J WF-- W � ti Z T- 00 N N O M Q 0'' O W �� Z 1- O -W 1 Z 'S U M v- D (- Q DATE 1 ISSUE 07.20.16 PERMIT SET PERV011' CIENTER A-5.1 2016-11-00 TILE / FLOOR SCHEDULE SCALE: NONE FLOOR FINISH GENERAL NOTES 1. CONTRACTOR TO CONFIRM TILE USED FOR PATCH AND NEW AREAS IS AN ACCURATE MATCH WITH EXISTING TILE BEFORE PURCHASE AND INSTALLATION. 2. CONTRACTOR TO VERIFY CONDITION OF EXISTING TILE IS SUITABLE TO REMAIN AND CONFIRM EXTENT OF NEW TILE WORK AND REPAIR REQUIRED. FLOOR FINISH PLAN s 1 SCALE: 1/4" = 1'-0" U) N r TILE FLOOR SCHEDULE _O O co O C U NO. MANUFACTURER DESCRIPTION SERIES MFG # ...... COLOR ..._ _... FINISH JOINT _..... _ __..,. GROUT _..... .: __..... .... REMARKS ._ . N a, L 0 cu -a U) co c o CT -01 EUROWEST 24" x 24" DELUXE CREMA POLISHED DINING- FIELD co � 00 � CT -02 EUROWEST 24" x 24" DELUXE OLIVE BROWN POLISHED DINING - ACCENT N CT -03 EURQWEST 6" x 24" COVE DELUXE CREMA POLISHED dC DINING - BASE Ff 0 CLN CT -04 UNUSED J Q Qcn CT -05 DALTILE 6".x 20" COVE VERANDA S-36E9T LEATHER cy) ~W T2 DINING O C) op oco CT -06 UNUSED ti Q W T- � N N �- UQ1") N (a N (o a , CT -07 UNUSED U) z Z off-' SSU Q- CT -08 EUROWEST 24" x 24" DELUXE M It- PERLA POLISHED T2 DINING FLOOR - FIELD CT -09 EUROWEST 24"x 24" DELUXE DELORIAN GREY POLISHED T2 DINING FLOOR.- ACCENT'. CT -10 EUROWEST 6" x 24" DELUXE DELORIAN GREY POLISHED T2 BASE QT -01 DALTILE 6" x 6" PAVERS OQ84 RED PAVER SMOOTH 3/8" G4 KITCHEN, PREP, STORAGE FLOORS QT -02 DALTILE 6" x 6" COVE PAVERS P-3665 RED PAVER SMOOTH 3/8" G4 KITCHEN, PREP, STORAGE FLOORS QT -03 ALFAGRES 411,x 8" TEAK RED SMOOTH 3/8" G4 CK SERVICE AREA FLOOR QT -04 ALFAGRES 6" x 6" COVE TEAK RED SMOOTH' 3/8" G44 CK SERVICE AREA BASE QT -05 ALFAGRES 6" x 6"COVE TEAK COFFEE SMOOTH 3/8" G4 T2 SERVICE AREA BASE QT -06 ALFAGRES 4" x 8" TEAK COFFEE SMOOTH 3/8" G4 T2 SERVICE AREA BASE TILE / FLOOR SCHEDULE SCALE: NONE FLOOR FINISH GENERAL NOTES 1. CONTRACTOR TO CONFIRM TILE USED FOR PATCH AND NEW AREAS IS AN ACCURATE MATCH WITH EXISTING TILE BEFORE PURCHASE AND INSTALLATION. 2. CONTRACTOR TO VERIFY CONDITION OF EXISTING TILE IS SUITABLE TO REMAIN AND CONFIRM EXTENT OF NEW TILE WORK AND REPAIR REQUIRED. FLOOR FINISH PLAN s 1 SCALE: 1/4" = 1'-0" U) W I D W U U) W z dC n J Q J d cy) ~W O C) �- pop ti Q W T- � N N �- UQ1") =SO U) z Z off-' SSU D Q M It- F -0 - DATE ISSUE 07.20.16 PERMIT SET A-5.2 2016-11-00 ZJND SAHL 1201 First Avenue South, Suite 310 Seattle, Washington 98134 206.402.5156 www.lundopsahl.com Project 16-098-02 Crispy Town Range Unit Plan Project No. 16-098-02 Date 07/20/2016 Reference Scale NTS Q10p© `5l2ANSlG11i1C,-- a��,c.c S -SK -01 Near>� icy Ir }- j. v') wt%IV "r') 1p, Sidfoo art '�G M Nva ATrnP-In Project 16-098-02 Crispy Town Range Unit Seismic Brace Detail @ Roof Project No. 16-098-02 Date 06/17/2016 �7C —S K-04 Reference Scale NTS It/h Mr-TAL P $ a f��0'Q+✓lafls oFPkood�. ?1040 ASC Pzr)asi1Yt'. c 24234 O TURAL ENG tV�V f SSIONAL E�G� 07/20/2016 1 AAA ONLY , Project 16-098-02 O UND Crispy Town Range Unit Hanging Detail SAHL Project No. 16-098-02 Date 07/20/2016 � � � 0 Gn 1201 First Avenue South, Suite 310 Seattle, Washington 98134 206-402-5156 www.lundopsahl.com Reference Scale NTS ) & \) tA-rT /�� ^,r �a1lr C� R ril F� fl i1. '-� Cy phi i J a1 C i @ I� ��; tf �l I 4, c �a 1 kw C L Z t F,A vi 0"'4 i' .r1 ��''C�?�J� `i l•\'��' ��?�'p:�1�k1� ��� t7,1�� tta �a�.w.��t*!?a :t:l�`t� �:bc;' k%oRATL, AMD WO IQ 6C960)S AVAP ,- 07/14/2016 Project 16-098-02 MUA Attachment Detail Project No. 16-098-02 Date 07/14/2016 S -SK -05 Reference 1 /M2.1 Scale NTS z W 24234 �� 4 'RAL ENG G ANAL EN 06/21/2016 3/k i K I,, kipw 11 .rZc�r�L CNN -) : NVQ' .(iYP,1 Nark, .e GP Tb MP -&tom C N r J N E2 :`= O N C � U i a o CU 0 3 � . J CU 0) 0 o > N U OC) 1 N �z�N U a� NN Q Q N Q 00 = O �ol caN f0 cc —. -5 to U) cL a) TW LT)JE W1 CORN\it!JG`31 l2GtNC+r? kl(yG� lV0't�.'° V'EFGP Tb ISTD U " M x'1'1 � �N D SAHL 1201 First Avenue South, Suite 310 Seattle, Washington 98134 206402-5156 w vlundopsahl.com Project 16-098-02 Crispy Town Range Unit Seismic Brace Detail @ Unit Project No. 16-098-02 Date 06/17/2016 S S K-03 Reference Scale NTS (::)Plan Scale: NTS LTD SAHL 1201 First Avenue South, Suite 310 Seattle, Washington 98134 206-402-5156 wwwlundopsahl.com Project 16-098-02 07/14/2016 I.•,-\ Qtur,7- IPQAtA NCS '1~0 Pep, pt-AVA cs� %Fk)'K MUA Support Angle and Detail Project No. 16-098-02 Date 07/14/2016 Reference 1/M2.1 Scale NTS VOL A Ci✓ DeR NeD p0 I%$ 29 pUG ",ka D,v,g�pN 4. 4.OCT. 03' RECEIVED CITY OF TUKWILA JUL 2 8 2016 PERMIT CENTER Cn J J WJ Q< 0 rn J 0 o W F— OC) 1 N �z�N Q 0 0 �<z ryo J W U) OC r n DATE ISSUE 07.20.16 PERMIT SET S--0.1 2016-11-00 ELECTRICAL SYMBOL LIST LIGHTING RACEWAYS TELECOMMUNICATIONS ABBREVIATIONS SURFACE METAL RECEPTACLE RACEWAY QA OR E;3A WALL MOUNTED LUMINAIRE V COMBINATION COMMUNICATIONS OUTLET. A AMPERES, AMBER A = ABOVE COUNTER WITH (2) CAT 5E FOR DATA, (1) CAT 5E FOR A SWITCHES AND RECEPTACLESPHONE. 11 AFF ABOVE FINISHED FLOOR _ RECESSED FLUORESCENT 2'X 4' LUMINAIRE =(A o� OA OR A SURFACE MOUNTED LUMINAIRE S SINGLE POLE SWITCH 2 = DOUBLE POLE SWITCH p DATA OUTLET, 3/4" CONDUIT WITH CAT 5E FOR DATA. SEE PLAN FOR 0- O 3 = THREE-WAY SWITCH c U) o NUMBER OF CABLES. AIC 4 = FOUR-WAY SWITCH f--�A SURFACE MOUNTED STRIP/COVE LUMINAIRE AV a THRU z (LOWERCASE) = LUMINAIRE CONTROL DESIGNATION ® TELEPHONE OUTLET, 3/4" CONDUIT R D = DIMMER A V) C M = MANUAL MOTOR STARTER WITH THERMAL OVERLOAD (S)A ®AOR RECESSED LUMINAIRE P = SWITCH WITH PILOT LIGHT a CODE LIST AT COMBINATION COMMUNICATIONS OUTLET FOR OPTIONS. CB SC = SPEED CONTROL A N CAN T = 15 MINUTE SPRING WOUND TIMER OA OR PENDANT MOUNTED LUMINAIRE WP = WEATHER PROOF SWITCH c4 RECEPTACLE. SEE LETTER CODE LIST AT COMBINATION CCN V = LOW VOLTAGE SWITCH �— IA PENDANT MOUNTED FLUORESCENT 1'X 8' LUMINAIRE S oc WALL MOUNTED OCCUPANCY SENSOR SWITCH AE FLUORESCENT LUMINAIRE CONNECTED TO EMERGENCY CIRCUIT OS CEILING MOUNTED OCCUPANCY SENSOR AE AEOR `E RECESSED LUMINAIRE CONNECTED TO EMERGENCY CIRCUIT OS WALL MOUNTED OCCUPANCY SENSOR OR AE PENDANT LUMINAIRE CONNECTED TO EMERGENCY CIRCUIT ® SPECIAL PURPOSE RECEPTACLE. SEE LETTER CODE LIST AT DUPLEX MISCELLANEOUS RECEPTACLE FOR OPTIONS A ZS L' A® TRACK LIGHTING. (E) TWISTLOCK RECEPTACLE. COORDINATE RECEPTACLE CONFIGURATION CONDUIT ELLED UP FA WITH EQUIPMENT BEING SUPPLIED. SEE LETTER CODE LIST AT DUPLEX 0-mA EXTERIOR POLE MOUNTED LUMINAIRE FACP RECEPTACLE FOR OPTIONS + A AREA BOLLARD WITH CONCRETE BASE -e SINGLE RECEPTACLE. SEE LETTER CODE LIST AT DUPLEX RECEPTACLE FAAP FOR OPTIONS •4 A FLOODLIGHT =0DUPLEX RECEPTACLE PLASTIC BUSHING A = ABOVE COUNTER A WALL MOUNTED SIGN LUMINAIRE GFI C = FLUSH CEILING MOUNTED GROUNDING POINT G, GND F = ARC FAULT PROTECTED BY BREAKER IN PANEL -► IG GFI = GROUND FAULT CIRCUIT INTERRUPTER A EXIT SIGN WALL MOUNTED, ARROW(S) INDICATES DIRECTION IF SHOWN GFCIP = GROUND FAULT CIRCUIT INTERRUPTER PROTECTED KV GFCIF = GROUND FAULT CIRCUIT INTERRUPTER FACELESS OR FLUSH MOUNT EQUIPMENT ENCLOSURE AS NOTED KVA IG = ISOLATED GROUND —" EXIT SIGN CEILING MOUNTED, SHADED AREA INDICATES NUMBER OF FACES KW P = PENDANT MOUNTED WITH CORD GRIPS. VERIFY PENDANT LENGTF ® A SHOWN, ARROW(S) INDICATES DIRECTION IF SHOWN TR = TAMPER PROOF M WP = WEATHER PROOF CONTINUOUS COVER AND GFCI PROTECTED 4C:INA EMERGENCY LIGHTING UNIT MCA MINIMUM CIRCUIT AMPS =0DOUBLE DUPLEX RECEPTACLE. SEE LETTER CODE LIST AT DUPLEX ® CONNECTIONS / EQUIPMENT RECEPTACLE FOR OPTIONS 9M OR ® RECEPTACLE, FLUSH FLOOR, FLUSH CEILING MOTOR CONNECTION NL NIGHT LIGHT Eli NON-FUSED DISCONNECT SWITCH NO NORMALLY OPEN -� BRANCH CIRCUIT WIRING. ARROW INDICATES HOME RUN TO PANEL RANGE RECEPTACLE li HEAVY DUTY FUSED DISCONNECT SWITCH PH PHASE 0 OR JUNCTION BOX O CLOCK RECEPTACLE T-1 TRANSFORMER © BELL © CONTACTOR COIL TTB TELEPHONE TERMINAL BOARD - - - - - - CONDUIT ROUTED BELOW FLOOR / GRADE M INTERCOM ® RELAY TVSS TRANSIENT VOLTAGE SURGE SUPPRESSOR WP� REFERENCE NOTE TYP TELEVISION WEATHER PROOF PUSH BUTTON UL UNDERWRITERS LABORATORIES F 2 TONE CHIME as TV CAMERA O SMOKE DECTECTOR, TYPE AS REQUIRED BY NFPA QM MAGNETIC DOOR HOLD V VOLTS, VOLTAGE (9) SPEAKER OSYS SMOKE DECTECTOR, SYSTEM TYPE W WIRE, WHITE TCO SMOKE DETECTOR, 120V CO 0 KEY PAD PC PHOTO CELL _ W - WEATHER PROOF CONTINUOUS COVER WITH 1 CONDUIT TO =(A o� JUL 2 8 2016 AFG ABOVE FINISHED GRADE p DATA OUTLET, 3/4" CONDUIT WITH CAT 5E FOR DATA. SEE PLAN FOR 0- O N c U) o NUMBER OF CABLES. AIC AVAILABLE INTERRUPTING CAPACITY 't rn w AV AUDIO VISUAL ® TELEPHONE OUTLET, 3/4" CONDUIT R N COO <C < m cm co V) C CONDUIT, CLOSE, CONTROL N Ltd CO Q 4- FLUSH FLOOR COMBINATION COMMUNICATIONS OUTLET. SEE LETTER a CODE LIST AT COMBINATION COMMUNICATIONS OUTLET FOR OPTIONS. CB CIRCUIT BREAKER N CAN CABLE TELEVISION ® FLUSH FLOOR COMBINATION COMMUNICATIONS OUTLET AND DUPLEX r c4 RECEPTACLE. SEE LETTER CODE LIST AT COMBINATION CCN CLOSED CIRCUIT TELEVISION, SECURITY COMMUNICATIONS OUTLET FOR OPTIONS. U� CLG CEILING TELEPHONE TERMINAL BOARD CU COPPER E EMERGENCY MISCELLANEOUS (E) EXISTING CONDUIT ELLED UP FA FIRE ALARM FACP FIRE ALARM CONTROL PANEL CONDUIT ELLED DOWN FAAP FIRE ALARM CONTROL PANEL CONDUIT/WIRING STUBBED OUT WITH END CAP OR INSULATED FLA FULL LOAD AMPS PLASTIC BUSHING GFI GROUND FAULT INTERRUPTER GROUNDING POINT G, GND GROUND IG ISOLATED GROUND SURFACE MOUNT EQUIPMENT ENCLOSURE AS NOTED KV KILOVOLT OR FLUSH MOUNT EQUIPMENT ENCLOSURE AS NOTED KVA KILOVOLT AMPERES KW KILOWATT girm BRANCH PANEL M MOTOR FLUSH WALL MOUNTED BRANCH PANEL MCA MINIMUM CIRCUIT AMPS MOCP MAXIMUM OVERCURRENT PROTECTION ® MAIN DISTRIBUTION PANEL/ SUB DISTRIBUTION PANEL NC NORMALLY CLOSED FLEXIBLE CONDUIT NL NIGHT LIGHT NO NORMALLY OPEN -� BRANCH CIRCUIT WIRING. ARROW INDICATES HOME RUN TO PANEL B-27,29 WITH CIRCUITS AS NOTED. PH PHASE (R) REMOVE CONDUIT CONCEALED IN WALL OR CEILING SPACE (RR) REMOVE AND RELOCATE TTB TELEPHONE TERMINAL BOARD - - - - - - CONDUIT ROUTED BELOW FLOOR / GRADE TVSS TRANSIENT VOLTAGE SURGE SUPPRESSOR O REFERENCE NOTE TYP TYPICAL UL UNDERWRITERS LABORATORIES O MECHANICAL EQUIPMENT CONNECTION ITEM. REFER TO SCHEDULE .UPS UNINTERRUPTABLE POWER SUPPLY V VOLTS, VOLTAGE VA VOLT AMPERES W WIRE, WHITE WP WEATHERPROOF N 4-22-17 =(A o� JUL 2 8 2016 U C 0- O N c U) o o. do 't rn w LE tfO Q N O E R N COO <C < m cm co V) co=oo N N N ca .3 N Ltd CO Q 4- N SX n= 4-22-17 =(A o� JUL 2 8 2016 W � PERMIT CENTER c o. do w LE 'p -: z ciuo- a Z N r c4 jie®► Q U� J J W d THIS DRAWING DATA AND DESIGNS THEREON SHALL NOT BE DUPLICATED, USED OR DISCLOSED TO OTHERS FOR PROCUREMENT OR OTHER PURPOSE, EXCEPT AS OTHERWISE AUTHORIZED BY CONTRACT, WITHOUT PERMISSION OF JET INDUSTRIES, INC. 1936 SILVERTON RD. SALEM, OR 97301 TEL: (603) 363-2334 FAX: (603)384-2488 OR CCB#' C226; CA CCB# 476267 LL REPRODUCTIONS SHALL BEAR THIS AS NOTICE. x W 0 Z W TW ♦Z V! � J J z Q O W O '' .-�� ■� .1„ , r w 00 Imo. (:0 N 00 W 0*) N �C nc, zqv ' U <>C a* U =�o W �z j o�_J SHEET INDEXui u) E0.1 ELECTRICAL - LEGEND /SHEET INDEX M D Q E2.1 ELECTRICAL - FLOOR PLAN - POWER E3.1 ELECTRICAL - FLOOR PLAN - LIGHTING DATE ISSUE E4.1 ELECTRICAL - PANEL / SCHEDULES 07.20.16 PERMIT SET s �u RECEIVED CITY OF TUKWILA JUL 2 8 2016 PERMIT CENTER 2016-11-00 0Nll� OMOUNT RECEPTACLE AND DATA CONNECTION FOR CT -18 TV -MENU BOARDS IN FACE OF OVERHEAD BULKHEAD, COORDINATE WITH ARCHITECT. OEXTEND CIRCUIT TO HOOD CONTROL PANEL. OMOUNT GFI RECEPTACLES UNDER COUNTER. ELECTRICAL - FLOOR PLAN - POWER 1/4" = 1'-0" PERMIT CENTER N p ti.. ��•.. L i. F ., N r N oO C co U 3:O U �- o cu oo c lu cu Lo m N Lo - N C Q E U �-> N C.0 a) C-4 cn 0000 �04 CUNN.� c0 Ot 1fAg8 t- �l� MMM 4-22-17 t2 CL o� W Q a-uj W Z . cm w 41 " =1 �o a jc- ° � Q W W 4, THIS DRAWING DATA AND DESIGNS THEREON SHALL NOT BE DUPLICATED, USED OR DISCLOSED TO OTHERS FOR PROCUREMENT OR OTHER PURPOSE, EXCEPT AS OTHERWISE AUTHORIZED BY CONTRACT, WITHOUT PERMISSION OF JET INDUSTRIES, INC. 1936 SILVERTON RD. SALEM, OR 97301 TEL: (603)363-2334 FAX: (503) 364-2488 OR CCB#' C226; CA CCB# 476267 ALL REPRODUCTIONS SHALL BEAR THIS NOTICE. ry W 3:O n I z Q J J J Q O O O O W��''`. _I LL I— w�N T- CV UQcr) C)��O W J F O�� �z W U) — W 0) M D Q DATE ISSUE 07.20.16 PERMIT SET E2.1 2016-11-00 ERAL NOTES REFER TO A-3.1 FOR FIXTURE TYPES AND DESCRIPTION. NOTES OCONNECT TO EXISTING CIRCUIT. ELECTRICAL -FLOOR PLAN - LIGHTING 1 All = 11-0'I RECEIVED CITY OF TUKWILA JUL 2 8 2016 N r r N 5 E C U U D- O cu cU)0 3 co 1-- � r CJ N L0 N C�(NO N E V Q-� N COO N QQ a)(OCO N 00=00 N N N .3 N EXPMES 4-22-17 THIS DRAWING DATA AND DESIGNS THEREON SHALL NOT BE DUPLICATED, USED OR DISCLOSED TO OTHERS FOR PROCUREMENT OR OTHER PURPOSE, EXCEPT AS OTHERWISE AUTHORIZED BY CONTRACT, WITHOUT PERMISSION OF JET INDUSTRIES, INC. 1936 SILVERTON RD. SALEM, OR 97301 TEL: (603)363-2334 FAX: (503) 364-2488 OR CCB#' C226; CA CCB# 476267 ALL REPRODUCTIONS SHALL BEAR THIS V Z cco iaoLuo V uicz =i0 ; t tt� LL o Z O E ti c E Q THIS DRAWING DATA AND DESIGNS THEREON SHALL NOT BE DUPLICATED, USED OR DISCLOSED TO OTHERS FOR PROCUREMENT OR OTHER PURPOSE, EXCEPT AS OTHERWISE AUTHORIZED BY CONTRACT, WITHOUT PERMISSION OF JET INDUSTRIES, INC. 1936 SILVERTON RD. SALEM, OR 97301 TEL: (603)363-2334 FAX: (503) 364-2488 OR CCB#' C226; CA CCB# 476267 ALL REPRODUCTIONS SHALL BEAR THIS V Z mr V E —� J J QO 5 O O w00ti O H T- N I.L w0N op ' U << a� �z W 0-w M D Q DATE ISSUE 07.20.16 PERMIT SET E3.1 2016-11-00 Panel A I I PANEL SCHEDULE N 5 PROJECT: PROJECT: 15-0487 1391 SOUTH CENTER MALL 15-0487 1391 SOUTH CENTER MALL 120/208V, 3Ph, 4W. 250A Bus 225A M.C.B. FLUSH MOUNTED M.L.O. LTG & APPLIANCE BRANCH PANELBOARD 1 Jul -16 Ckt. Description Load Load C.B. Load C.B. C.B. Load Load escriptlon / Ckt. No. Location (VA) Type Amp/Pole Notes Ph. Notes Amp/Pole (VA) Type Location No. 1 Lighting 950 L 20/1 A A 20/1 336 R POS (Cashier) w/ printer CT -01, CT -02 2 3 Lighting 950 L 20/1 B B 20/1 336 R POS (Cashier) w/ printer CT -01, CT -02 4 5 Lighting 272 L 20/1 C C 20/1 1,200 K I Ice Maker 6 7 Lighting 900 L 20/1 A A 20/1 500 R Counter Scale System - CT -05 8 9 Spare 0 20/1 B B 20/1 420 K Food Processor 10 11 Receptacles 900 R 20/1 C C 20/1 1,176 K Mini Oven - M-02 12 13 Freezer 1,476 K 20/1 A A 20/1 216 K Braising Pan 30 gal. - M-03 14 15 Refrigerator 1,548 K 20/1 B B 20/1 360 R Roof Receptacle 16 17 Hood 850 K 20/1 C C 20/3 840 K Hood - Fryer Control Box 18 19 Steamer - M-04 2,645 K 30/3 A 11840 20/1 K " 20 21 2,645 K 1.B 20/1 B "• 840 K It 22 23 2,645 K 1.C 20/1 25/3 2,160 H RTU -2 24 25 EF -2 1,320 K 20/3 A A 2,160 H K 26 27 to1,320 27 Bain Marie Warmer - CT -03 K " B B 2,160 H K 28 29 to1,320 29 " K It C 1 100/3 12,391 0 Panel C 30 31 MUA-2 938 K 15/3 A A to 11,070 0 to 32 33 " 938 K It B B to 13,368 0 to 34 35 to 938 K It C C 20/1 0 0 Spare 36 37 Spare 0 0 20/1 A A 20/1 0 0 Spare 38 39 Spare 0 0 20/1 B B 20/1 0 1 0 Spare 40 41 Spare 0 0 20/1 C C 20/1 0 0 Spare 42 Total Connected Load: Ph A Total Connected Load: Ph A 195 A 103 A Total Connected Load: Ph B M7A VA 207 A 27,191 A rms Available Fault Duty Total Connected Load: Ph C VA VA 206 A "Maximum" Phase Connected Load: "Maximum" Phase Connected Load: Ph B 24,885 VA Total Connected Load (3 X Maximum): Total Connected Load (3 X Maximum): 74.7 KVA 207.4 AMPS Total Demand Load: 53.2 KVA 147.7 AMPS 24.7 KVA 68.7 AMPS Accessories: Accessories: SOURCE = Switchboard C1 SOURCE= Panel A NOTES: NOTES: 1, Provide Shunt -Trip circuit breaker 1. CEILING MOUNTED J -BOX CONNECTION CONFIRM WITH KITCHEN SUPPLIER 2. 2. 3. 3. 4. 4. 5. 5. Load Load Description Load Load Description Connected Subfed Subfed Total Demand Demand Demand Type Type Loads Loads (S) Loads(S) Loads Factor Load Load G General (Non -Continuous) G General (Non -Continuous) 0 0 0 100% 0 0 L Lighting L Lighting 3,072 0 3,072 125% 0 3,840 R Receptacles - to 10 KVA R Receptacles - to 10 KVA 2,432 2,310 4,742 100% 2,310 4,742 over 10 KVA over 10 KVA 0 0 50% 0 0 K Kitchen K Kitchen 24,115 34,519 58,634 65% 22,437 38,112 H Heating H Heating 6,480 0 6,480 100% 0 6,480 M Motors M Motors 0 0 0 100% 0 0 LM Largest Motor LM Largest Motor 0 0 0 125% 0 0 WH Water Heater WH Water Heater 0 0 0 125% 0 0 C Continuous General Load C Continuous General Load 0 0 0 125% 0 0 U <User Defined Load Type> U <User Defined Load Type> 0 0 0 100% 0 0 0 0 0% 0 0 0 0 0% 0 0 O 0 0% 0 0 TOTALS TOTALS 36,099 VA 36,829 VA 72,928 VA 24,747 VA 53,174 VA Panel C I r r PANEL SCHEDULE N 5 E PROJECT: U 15-0487 1391 SOUTH CENTER MALL 120/208V, 3Ph, 4W. 125A Bus M.L.O. FLUSH MOUNTED c 00 LTG & APPLIANCE BRANCH PANELBOARD 1 -Jul -16 Ckt, Description / Load Load C.B. N <( QN sD C , C.B. Load Load Description Ckt, No. Location (VA) Type Amp/Pole Notes Ph. Notes Amp/Pole (VA) Type Location No. 1 SPARE 0 20/1 A 20/1 0 r\� SPARE 2 3 SPARE 0 J 20/1 B a� 20/1 0 -5 SPARE 4 5 Infra -Black Strip Heater - CT -04 1,490 K 20/1 1 C 20/1 1,130 K Infra -Black Strip Heater - CT -06A 6 7 Bain Marie Warmer - CT -03 2,250 K 30/2 A U 20/1 980 K Infra -Black Strip Heater - CT -06B 8 9 112,250 K " B O 20/1 650 R LED TV Menu Board - CT -18 10 11 Infra -Black Strip Heater - CT -04 1,490 K 20/1 1 C D 20/1 650 R LED TV Menu Board - CT -18 12 13 Microwave Oven - M-06 2,912 K 40/2 A 20/1 650 R LED TV Menu Board - CT -18 14 15 If2,912 K " B 20/1 396 K Beverage Dispenser - CT -17 16 17 Microwave Oven - M-06 2,912 K 40/2 C 20/1 396 K Beverage Dispenser - CT -17 18 19 " 2,912 K 1.A 20/1 77 K Rice Warmer - CT -14 20 21 Chiller - Glass Slide Door - CT -16 912 K 20/1 B 20/1 100 K Soup warmer 22 23 Undercourter Frig 800 K 20/1 1 30/2 2,250 K Bain Marie Warmer- CT -05 24 25 Undercounter GFI 360 R 20/1 A " 2,250 K 26 27 Bain Marie Warmer - CT -03 2,250 K 30/2 B 20/1 1,600 K Coffee 28 29 " 2,250 K 11C 20/1 0 1.30 31 SPARE 0 20/1 A 20/1 0 1.32 33 0 20/1 B 20/1 0 to34 35 0 20/1 C 20/1 0 to 36 37 0 20/1 A 20/1 0 It38 39 to 0 20/1 B 20/1 1 0 " 40 41 " 0 20/1 C 20/1 0 1142 Total Connected Load: Ph A VA 103 A Total Connected Load: Ph B VA 92 A 19,666 A rms Available Fault Duty Total Connected Load: Ph C VA 111 A "Maximum" Phase Connected Load: Ph C 13,368 VA Total Connected Load (3 X Maximum): 40.1 KVA 111.4 AMPS Total Demand Load: 24.7 KVA 68.7 AMPS Accessories: SOURCE= Panel A NOTES: 1. CEILING MOUNTED J -BOX CONNECTION CONFIRM WITH KITCHEN SUPPLIER 2. 3. 4. 5. Load Load Description Connected Subfed Total Demand Demand Type Loads Loads (S) Loads Factor Load G General (Non -Continuous) 0 0 100% 0 L Lighting 0 0 125% 0 R Receptacles - to 10 KVA 2,310 2,310 100% 2,310 over 10 KVA 0 50% 0 K Kitchen 34,519 34,519 65% 22,437 H Heating 0 0 100% 0 M Motors 0 0 100% 0 LM Largest Motor 0 0 125% 0 WH Water Heater 0 0 125% 0 C Continuous General Load 0 0 125% 0 U <User Defined Load Type> 0 0 100% 0 0 0% 0 0 0% 0 O 0% 0 TOTALS 36,829 VA 0 VA 36,829 VA 24,747 VA N co r r N 5 E U) U C a0 cc o c 00 oaN°E .= CL N COO N <( QN sD C , Cn N 00 O O N N N Cc .3 � -� u7 CO Q v_ N 4 TAS r ✓c ''A ins 4-22-17 0 13 loW 0 a W W co x 9 W W THIS DRAWING DATA AND DESIGNS THEREON SHALL NOT BE DUPLICATED, USED OR DISCLOSED TO OTHERS FOR PROCUREMENT OR OTHER PURPOSE, EXCEPT AS OTHERWISE AUTHORIZED BY CONTRACT, WITHOUT PERMISSION OF JET INDUSTRIES, INC. 1836 SILVERTON RD. SALEM, OR 87301 TEL: (503) 363-2334 FAX: (603)384-2488 OR CCB#' C228; CA CCB# 478287 ALL REPRODUCTIONS SHALL BEAR THIS OCT. 0" 211"11 DATE ISSUE 07.20.16 PERMIT SET RECEIVED CITY CP TUKWILA JUL 2 8 2016 PERMIT CENTER ^6 h Iu ;l -'Ai JD r Fry } E4 1 f ,• �. s J n8..+1n..,E •f RE°..��.§ 2016-11-00 co W J TW t1, rVn w / r\� J Q a� _ Q -5 g E- WF- Wo W 00 'r0000L t O w0)N 1 04 UQ� U ��o Wz 1� J O J J f CO D Q OCT. 0" 211"11 DATE ISSUE 07.20.16 PERMIT SET RECEIVED CITY CP TUKWILA JUL 2 8 2016 PERMIT CENTER ^6 h Iu ;l -'Ai JD r Fry } E4 1 f ,• �. s J n8..+1n..,E •f RE°..��.§ 2016-11-00 EQUIPMENT SCHEDULE SYMBOL DESCRIPTION ELECTRICAL MAU-3 MODULAR MAKEUP AIR UNIT: GAS HEAT, NO COOLING. 208 V/ 3 PH U �- o 1,700 CFM AT 0.75 IN. E.S.P. 3.4 FLA; 1 HP c �cu m% C\I Lo DIRECT FIRED GAS HEATING: 131.2 MBH INPUT; 120.7 MBH OUTPUT; 92% THERMAL EFFICIENCY. 4.7 MCA cu o`�N� PROVIDE WITH MOTORIZED INTAKE DAMPER, ROOF CURB. VFD RATED MOTOR N << a'coco'n APPROXIMATE OPERATING WEIGHT: 800 LBS. CONTROL: HOOD PANEL. m .3 04 n Lo (n 0. ;-: BASIS OF DESIGN: CAPTIVE AIRE UNIT A1 -D.250 -G10. CIRCUIT WITH EF -3 0 z F- O O O W W EF -3 EXHAUST FAN: 208 V/3 PH 'm pop~ U IL Moo 2,000 CFM AT 1.0 IN. E.S.P. 3.8 FLA 5 Or .a a W SONES: 12.7 MAXIMIM. 5.2 MCA W RATED FOR GREASE; PROVIDE WITH HINGE KIT. 20 MOCP z G�- z / W -I APPROXIMATE OPERATING WEIGHT: 150 LBS. VFD RATED MOTOR ~ Q V- I- BASIS OF DESIGN: CAPTIVE AIRE DU180HFA. CONTROL: HOOD PANEL. Y H-3 TYPE I HOOD: 115 V/ 1 PH LIGHT CIRCUIT 6-2" LONG, PERFORATED SUPPLY PLENUM, 9 MICRON FILTERS. 115 V/ 1 PH ANSUL CIRCUIT EXHAUST AT 2,000 CFM, SUPPLY AT 1,700 CFM. 430 STAINLESS STEEL, REMOTE DCV CONTROL PANEL. APPROXIMATE OPERATING WEIGHT: 410 LBS. BASIS OF DESIGN: CAPTIVEAIRE ND5430 ND -2 -PSP -F. MECHANICAL SYMBOL LIST GENERAL NOTES DUCTWORK 1. PROVIDE AND INSTALL 1%" INSULATION ON REFRIGERANT CD CEILING DIFFUSER PIPING. ® CND CONDENSATE DRAIN 2. PROVIDE AND INSTALL MINIMUM R4.2 DUCT INSULATION FOR ® SUPPLY OR OUTSIDE AIR INDOORS CONDITIONED, R5.0 DUCT INSULATION FOR CFM CUBIC FEET PER MINUTE INDOORS UNCONDITIONED AND R8.0 DUCT INSULATION FOR RETURN AIR OUTDOORS ON ALL SUPPLY DUCTS. INSULATED UNLESS OTHERWISE NOTED.URN DUCTS ARE COP COEFFICIENT OF PERFORMANCE CONT. CONTINUATION 3. SEAL ALL DUCT SEAMS WITH MASTIC OR FOIL BACKED DUCT ® ® EXHAUST AIR TAPE. © CU CONDENSING UNIT 4. PROVIDE O&M MANUALS TO OWNER ON ALL MECHANICAL AC -1 ROOM THERMOSTAT D DROP EQUIPMENT. 5. AIR BALANCE TO +10% OR -5% OF INDICATED FLOWS TO QS SENSOR DB DECIBEL EACH GRILLE/DIFFUSER. DB DRY BULB 6. PROVIDE START-UP ON ALL EQUIPMENT PER AC -1 EQUIPMENT IDENTIFICATION DIA DIAMETER MANUFACTURERS RECOMMENDATION. CD -1 100 7. THERMOSTATS TO BE 7 -DAY PROGRAMMABLE WITH 6"0-4 DIFFUSER OR GRILLE IDENTIFICATION DX DIRECT EXPANSION 5 -DEGREE DEADBAND AND NIGHT SET -BACK CAPABILITY. EAT ENTERING AIR TEMPERATURE 8. PROVIDE ELECTRIC STRIP HEAT LOCKOUT ON ALL HEAT DAMPERS EDH ELECTRIC DUCT HEATER PUMPS AND SET AT 32 DEGREES. VOLUME DAMPER EER ENERGY EFFICIENCY RATING EF EXHAUST FAN FIRE DAMPER FD EEF EFFICIENT FIRE/SMOKE DAMPER EL ELEVATION FSD ELEC ELECTRICAL SMOKE DAMPER SD EXH EXHAUST I MOTORIZED DAMPER F FAHRENHEIT M FD FIRE DAMPER DUCTWORK FITTINGS FLA FULL LOAD AMPS FT FEET MITERED ELBOW WITH ' TURNING VANES HP HEAT PUMP HP HORSEPOWER RADIUSED ELBOW HTR HEATER RECTANGULAR MAIN WITH IE INVERT ELEVATION ROUND BRANCH IN INCHES RECTANGULAR MAIN WITH KW KILOWATT RECTANGULAR BRANCH LAT LEAVING AIR TEMPERATURE ROUND MAIN REDUCING WITH LBS. POUNDS ROUND BRANCH MA MIXED AIR CONCENTRIC SQUARE TO MAX MAXIMUM ROUND MBH THOUSAND BTU'S PER HOUR ECCENTRIC TRANSITION, RECTANGULAR OR ROUND MD MOTORIZED DAMPER MH MOUNTING HEIGHT NON -SYMMETRICAL WYE MIN MINIMUM SYMMETRICAL WYE N/A NOT APPLICABLE NTS NOT TO SCALE RECTANGULAR DUCT RISER OA OUTSIDE AIR ROUND DUCT RISER OBD OPPOSED BLADE DAMPER OD OUTSIDE DIAMETER RECTANGULAR DUCT DROP PH PHASE ROUND DUCT DROP QTY QUANTITY RA RETURN AIR RECTANGULAR OFFSET LESS THAN 150 RET RETURN RPM REVOLUTIONS PER MINUTE RECTANGULAR OFFSET MORE THAN 150 SA SUPPLY AIR SEER SEASONAL ENERGY EFFICIENCY RATING ROUND WYE SF SQUARE FEET ROUND DUCT WITH ROUND SH SENSIBLE HEAT BRANCH SP STATIC PRESSURE CONCENTRIC TRANSITION, TEMP TEMPERATURE SHEET INDEX RECTANGULAR OR ROUND UH UNIT HEATER MO.1 HVAC - LEGEND / SHLRT`1�01EX� ACCOUSTICALLY LINED V VOLT M2.1 HVAC - FLOOR PLAN - 4 p DUCT "INSIDE DIMENSION" i " Ll ' " " (OUTSIDE DIMENSION)" VD VOLUME DAMPER (HAND OPERATOR) M4.1 HVAC - DETAILS M4.2 HVAC - DETAILS W WA17 M4.3 HVAC - DETAILS ABBREVIATIONS M4.4 HVAC - DETAILS W/ WITH M4.5 HVAC - DETAILS M4.6 HVAC - DETAILS A/C AIR CONDITION(ED) WB WET BULB M4.7 HVAC - DETAILS AD ACCESS DOOR W/O WITHOUT AFF ABOVE FINISHED FLOOR RECEIVED BDD BACKDRAFT DAMPER CITY OF TUKWILA JUL 2 8 2016 PERMIT CENTER �q'9�c 51�Y 4 Y ♦y I' Ff f', , f� P �'•)��.a� � / �i��IL3 3 r N N ❑ N C � O U E U �- o m o c �cu m% C\I Lo o u- co �rnd-a) N Lo cu o`�N� E -C O�N� N << a'coco'n z Do=o0 N N N m .3 04 n Lo (n 0. ;-: N .,ort ire qv EXPFM 4-22-17 a 92 0 W O E O CL W uj o u- W W z Z t 0 z O O O W LU cn C � I•T 1 ❑ ISI 'm pop~ U W Moo W� U .a a W 0) U / THIS DRAWING DATA AND DESIGNS THEREON SHALL NOT BE DUPLICATED, USED OR DISCLOSED TO OTHERS FOR PROCUREMENT OR OTHER PURPOSE, EXCEPT AS OTHERWISE AUTHORIZED BY CONTRACT, WITHOUT PERMISSION OF JET INDUSTRIES, INC. 1935 SILVERTON RD. SALEM, OR 97301 TEL: (503) 363.2334 FAX: (503) 363-2622 OR CCB#'8 3944,158944,158633,166248,17C982 ALL REPRODUCTIONS SHALL BEAR THIS 16- NOTICE. W 0 E IIIW W Z U) O O W LU O pop~ E W Moo N U < 0) U ��o Q G�- z / Q U)_ -I ui c) ~ Q V- I- n DATE ISSUE 07.20.16 PERMIT SET M0.1 2016-11-00 HVAC - FLOOR PLAN 1/411 /4" = 1'-01' GENERAL NOTES ALL ROOFTOP UNITS, EXHAUST FANS AND MAKE -UP -AIR UNITS ARE EXISTING. CLEAN COILS, REPLACE BELTS, REPLACE FILTERS. REPLACE MOTOR FOR EF -2 TO BE COMPATIBLE WITH VFD. SIZE TO 1hp. REPLACE MOTOR FOR MAU-2 TO BE COMPATIBLE WITH VFD. SIZE TO 1hp. NOTES OCUT NEW DROPS THROUGH ROOF FROM UNIT. EXTEND NEW DUCTWORK TO AND TIE INTO EXISTING DUCTWORK, DIFFUSERS, GRILLES. OPROVIDE (1) LAYER OF 3M 615 PLUS GREASE WRAP ON GREASE DUCT. OBALANCE TO CFM SHOWN. O416"0 TAP TO HOOD AND TRANSITION TO 14"x14" 16 GAUGE STEEL GREASE DUCT, WELD TO HOOD. TRANSITION AND WELD TO EXISTING DUCT WORK. ALL JOINTS WELDED LIQUID TIGHT AND EITHER LIGHT TESTED OR PRESSURE TESTED. OBALANCE EF -2 TO 2,000 CFM. OBALANCE MAU-2 TO 1,450 CFM. MODIFY CONTROLS TO BE COMPATIBLE WITH ENERGY MANAGEMENT SYSTEM. CONTACT CAPTIVE-AIRE FOR WIRING DIAGRAM. O7 REFER TO HOOD DRAWING FOR TAP SIZES. OCUT HOLE IN ROOF FOR NEW DUCTWORK. OHOOD CONTROL PANEL. PERMIT CENTER ,ii �Sd z�,+yOG I ib: 1Cwi JJ R� C U) U cu U N E C U) U cu U 0- o cu co c J >%0 U�a)�rnr �go� C-4 Lo OQNCA cu E .� CL N N Q Q co U) Oo o o � N cu cq m -� Lo co � o%I FPO ohj 71 EXPlI= 4-22-17 o� W� Lu — a z 0.. o J W �go� D M Z ca Wco w � LL [� � 1®1 W UQcy) N r 'S O <C >� D � ... J 0 � lrT,l 0 1�1 Q Eca c � = W J Q J W a - n THIS DRAWING DATA AND DESIGNS THEREON SHALL NOT BE DUPLICATED, USED OR DISCLOSED TO OTHERS FOR PROCUREMENT OR OTHER PURPOSE, EXCEPT AS OTHERWISE AUTHORIZED BY CONTRACT, WITHOUT PERMISSION OF JET INDUSTRIES, INC. 1935 SILVERTON RD. SALEM, OR 97301 TEL: (503) 363-2334 FAX: (503) 363.2622 OR CCB#'8 3944,156944,158833,186248,170952 ALL REPRODUCTIONS SHALL BEAR THIS NOTICE. z J J 075 o O J Wco � LL �N� � W UQcy) N r 'S O <C >� D � z J ui Q n DATE ISSUE 07.20.16 PERMIT SET M2.1 2016-11-00 )TAL HOOD HOOD CONFIG. 4 (LBS.) SONES FIRE END 12.7 FMY CONSTRUCTION ENDO ROW SYSTEM 430 SS SWITCHES 208 700 586 ALONE ALONE HANGING Where Exposed SIZE MODEL # FOR QUESTIONS, CALL KURT CURTIS: REGIONAL MANAGER PHONE: (360) 828-5418 FAX: (919) 227-5983 EMAIL: kurt.curtis@captiveaire.com -IT(S) UTILITY CABINET(S) WEIGHT 4 (LBS.) SONES FIRE HOOD 12.7 VOLT FLA (LBS.) FIRE SYSTEM ELECTRICAL SWITCHES 208 WIRE 586 18.9 SYSTEM HANGING TYPE SIZE MODEL # QUANTITY �E GUARD LOCATION SIZE PIPING WIGHT es E26 NO YES 406 LBS C, IIRR NO. WEIGHT WEIGHT 4 (LBS.) SONES 3 117 12.7 C, IIRR NO. FANS CONTROLLED WEIGHT ITEM WEIGHT H.P. BURNER -1.P. O VOLT FLA (LBS.) SONES C EFFICIENCY(/o) 450 3 208 3.4 586 18.9 92 C, IIRR NO. FANS CONTROLLED WEIGHT ITEM SIZE H.P. FAN FLA Smart Controls DCV KEX-1 1 # 1 41 LBS Curb 26.500"W x 26.500"L x 20.000"H Vented Hinged 2 #2 63 LBS Curb 21.000"W x 71.000"L x 20.000"H Insulated OPTION FANS CONTROLLED FAN TAG TYPE 41, H.P. VOLT FLA Smart Controls DCV KEX-1 Exhaust 3 1.000 208 3.8 MUA-1 Supply 3 1.000 208 3.4 c /STEo us wek � 7 r� BUILT ,ar `�. ACCORDANCE IF M A, L W TH ITF �7 NFPA No. 96 CAPTIVE-AIRE HOODS ARE BUILT IN COMPLIANCE WITH UL 710 AND NFPA96 AND ARE RECOGNIZED BY ONE OR MORE OF THE FOLLOWING: ETL SANITATION LISTED ETL LISTED FILE# 3054804-001 N r N N a)O C M U U E: -U)0 ca�0),tMr Lo (D C Q N E CL N .0 COON QQ N(6(6 N CID =o0 CN MNN.� Lo C/) Q4- ai Off, I FF'pA oFj 'A EagPEB 4-22-17 Wcz cc E w LUp cc M Uj G It 14x rca VJ LN�L/I LL V/ 0 z w ILL. 0 Z V5 0 2 c THIS DRAWING DATA AND DESIGNS THEREON SHALL NOT BE DUPLICATED, USED OR DISCLOSED TO OTHERS FOR PROCUREMENT OR OTHER PURPOSE, EXCEPT AS OTHERWISE AUTHORIZED BY CONTRACT, WITHOUT PERMISSION OF JET INDUSTRIES, INC. 1935 SILVERTON RD. SALEM, OR 97301 TEL: (503) 363-2334 FAX: (503) 363-2622 OR CCBV8 3944,158944,158633,186248,17C982 ALL REPRODUCTIONS SHALL BEAR THIS U J J < o Q o W W 00 Z00o LU cr) _ UQ� til y i! C k CCC W �— cn U XT o L1) 2n1 vH� -D.4-7' C* •Ik.ji7t[:j 1 2682831 D -R. 4 XIV BY Sean Elias SCA -ZZ 3/811 = 1'-0„ DATE ISSUE 07.20.16 PERMIT SET M4.1 2016-11-00 EXHAUST RISER HANGING ANGLE 20" CAPTRATE SOLO FILTER WITH HOOK 3" INTERNAL STANDOFF IT IS THE RESPONSIBILITY OF THE ARCHITECT/OWNER TO ENSURE THAT THE HOOD CLEARANCE FROM LIMITED -COMBUSTIBLE AND COMBUSTIBLE MATERIALS IS IN COMPLIANCE WITH LOCAL CODE REQUIREMENTS. GREASE DRAIN WITH REMOVABLE CUP L55 SERIES E26 CANOPY LIGHT FIXTURE - HIGH TEMP ASSEMBLY, INCLUDES CLEAR THERMAL AND SHOCK RESISTANT GLOBE <L55 FIXTURE) ATTACHING 30" NOM, 48.0" MAX 430ND-2-PSP-F 'CHEN SUPPLY RISER WITH VOLUME DAMPER 23.5! OPEN STAINLESS STEEL PERFORATED PANEL 20" r A s "EE TEMP ►ENSOR DETAIL U.L. Listed L55 Series E26 Canopy Light Fixture - High Temp Assembly 7" J_ do 37" 24 3/4" 24 3/4" 6' 2.00"Nom./6' 2.00"CID ----- 6'-8.00" Overatt Length .2 ;*� yam. .�' � ♦ F `y �, RECEIVED CITY OF TUKVIILA JUL 2 8 201 PERIUIIT CEN ER TDB Tokvo Tokvo South Center Matt Crisov Town .LOCdTION SEATTLE, WA, 98188 B TB 6129/2016 JOB 2682831 mC # 2 B. N' BYSean Elias "Y S"CALZ 318" = 1'-0" N � J Q 0 r N N O C U (D ' ' U n- O cu C W 00 N � W U U NLID N N'C>QN 0� E ._ OR > N cD N aQ�(6�(n 00 o o N N .3 � 0J �5U ,r VAs r a -A f ElaqffS 4-22-17 t i t i Zm Cm ua tl. er THIS DRAWING DATA AND DESIGNS THEREON SHALL NOT BE DUPLICATED, USED OR DISCLOSED TO OTHERS FOR PROCUREMENT OR OTHER PURPOSE, EXCEPT AS OTHERWISE AUTHORIZED BY CGNTRACT, WITHOUT PERMISSION OF JET INDUSTRIES, INC. 1935 SILVERTON RD. SALEM, OR 97301 TEL: (503) 363.2334 FAX: (503) 363.2622 OR CCB#'S 3944, 156944,158833,166248,17C982 ALL REPRODUCTIONS SHALL BEAR THIS NOTICE. G7 J � J Q 0 _ Q ~W W 0 O � � � N � W U Q N °*) Q �Z _ 0J �5U DATE ISSUE 07.20.16 PERMIT SET M4.2 2016-11-00 LIGHT AND FAN SWITCHES 2011 x 18" S/S WALL BOX thtertek 20" 18•• 8.62,• 18" 4: r.:. '•`+alt � r..w. ANO SPECIFICATION: CAPTRATE GREASE -STOP SOLd FILTER THE CAPTRATE GREASE -STOP SOLO FILTER IS A SINGLE -STAGE FILTER FEATURING A UNIQUE S -BAFFLE DESIGN IN CONJUNCTION WITH A SLOTTED REAR BAFFLE DESIGN, TO DELIVER EXCEPTIONAL FILTRATION EFFICIENCY. FILTER IS STAINLESS STEEL CONSTRUCTION, AND SIZED TO FIT INTO STANDARD 2 -INCH DEEP HOOD CHANNEL(S). UNITS SHALL INCLUDE STAINLESS STEEL HANDLES AND A FASTENING DEVICE TO SECURE THE TWO COMPONENTS WHEN ASSEMBLED. GREASE EXTRACTION EFFICIENCY PERFORMANCE SHALL REMOVE AT LEAST 75% OF GREASE PARTICLES FIVE MICRONS IN SIZE, AND 90% GREASE PARTICLES SEVEN MICRONS IN SIZE AND LARGER, WITH A CORRESPONDING PRESSURE DROP NOT TO EXCEED 1.0 INCHES OF WATER GAUGE. THE CAPTRATE GREASE -STOP SOLO WAS TESTED TO ASTM STANDARD ASTM F2519-05. FILTER COLLECTION EFFICIENCY2" Captrat®Grease-Sto®Solo Filter 100 90 80 70 W 60 HU W 50 w O 40 30 [L 20 10 0.1 1 ]0 PARTICLE DIAMETER (um) CAPTRATE FILTERS ARE BUILT IN COMPLIANCE WITH:. NFPA #96 NSF STANDARD #2 UL STANDARD #1046 INT. MECH. CODE (IMC) PSP HANGING ANGLE 1/2" DIA. ALL THREAD ROD CONNECTED TO ROOF JOIST THROUGH ANOTHER HANGING ANGLE RESISTANCE VS. AIRFLOW - 2" Captrat®Grease-St( ®Solo Filter 1.6 1.4 1.2 1 0.8 0.6 0.4 0.2 0 o zoo AIRFLOW (din) soo STEEL HANGING ANGLE 1/2" DIA. HEAVY DUTY NUT AND WASHER - ONE ABOVE AND ONE BELOW HANGING ANGLE ROD, NUTS, AND WASHERS TO BE SUPPLIED BY INSTALLING CONTRACTOR HANGING ANGLE IS PRE -PUNCHED AT FACTORY 1/2" DIA. ALL THREAD ROC CONNECTED TO ROOF THROUGH ANOTHER HANGING ANGLE CORNER HANGING ANGLE e-reeL HANGING ANGLE 1000 BUILT IN z his ACCORDANCE < WITH NFPA vti ° No. 96 oa C/STEL 1/2" DIA. HEAVY DUTY NUT AND WASHER - ONE ABOVE ID ONE BELOW HANGING ANGLE ROD, NUTS, AND WASHERS TO BE SUPPLIED BY INSTALLING CONTRACTOR HANGING ANGLE IS PRE -PUNCHED AT FACTORY DUCT THERMISTOR SENSOR INSTAEEATION NOTE: Thermistor has 2 wires that connect to control cabinet 1/2' NPT Quik Seal (Adapter Body) Part # 32-00002--\ Thermistor Temperature Sensor Part #A/CP-PO-4'-EXPL-HT 1/2' Quik Seal (Gasket) Part # 32-00002 Extension Ring 59361-1/2 PSP THERMISTOR SENSOR INSTALL NOTE Thermistor has 2 wires that connect to control cabinet, If prewire is mounted on same hood in utility cabinet, factory wire sensors to the package per schematic, 1/2' NPT Quik Seal (Adapter Body) Part # 32-00002 1/2' Qulk Seal (Gasket) Part # 32-00002 Top of PSP (External Surface) 1 1/8' - 1 1/4' Diameter Hole 1/2' Quik Seal (Lock Washer) Part #32-00002 1/2' Conduit Lock Nut Part #LN101SC 1/2' NPT Qulk Seal (Nut) Part #32-00002 BUILT ®® � IN A#% Am h==M= 0 ACCORDANCE ® ® ® ® Jam® WITH fig ®®® 1011 NPA ,�j�l� _® p� No. 96 C C /STEO us Intertek Thermistor Temperature Sensor Part #A/CP-PO-4"EXPL-HT Junction Box Part # 58361-1/2 1/2' Conduit Lock Nut Part #LN101SC Extension Ring Cover 100 -BW Label as MUA Stat or AC Stat as necessary Stat must be centered in width Duct nal Surface) 1 1/8' - 1 1/4' Diameter Hole 1/2' Quik Seal (Lock Washer) Part #32-00002 VKNOTEI EXTENSION 1/2' NPT Qulk Seal (Nut) RING TO BE Part #32-00002 TACK WELDED TO DUCT OR RISER Ring Cover Must remain towards center but can adjust towards ECP to avoid riser interference JOB Tokyo Tokyo South Center Mall Crispy Town 7 LOCATION SEATTLE, WA, 98188 75 OCT o 1`i JOB Tokyo Tokyo South Center Mall Crispy Town r r LOCATION SEATTLE, WA, 98188 75 C _DATE 6/29/2016 TOB # 2682831 �- 0 .DTYG # 3 - D.R14 Tf�V BY Sean Elias 00 REV. ,SCALL' 3/811 = 1'-011 O7 Q CV 0') U N Ln (1)c! 0' N E w N < < a) o ? F, rl tr .3 C�_J U N J J r r coE 75 C 0 W v �- 0 M Cao Z 00 o � 't W O7 Q CV 0') U N Ln (1)c! 0' N E .0 0 N N < < a) o co 00 o co N N N .3 C�_J ov J� , 44.1cri Eal= 4-22-17 c� z THIS DRAWING DATA AND DESIGNS THEREON SHALL NOT BE DUPLICATED, USED OR DISCLOSED TO OTHERS FOR PROCUREMENT OR OTHER PURPOSE, EXCEPT AS OTHERWISE AUTHORIZED BY CONTRACT, WITHOUT PERMISSION OF JET INDUSTRIES, INC. 1935 SILVERTON RD. SALEM, OR 97301 TEL: (503) 3532334 FAX: (503) 363.2622 OR CCB#'8 3944,156944,150633,166248,17C982 ALL REPRODUCTIONS SHALL BEAR THIS NOTICE. J J J —Q < 75 o W ry LU 00 o Z 00 o W O7 Q CV 0') Q -Z C�_J U M <C r DATE ISSUE 07.20.16 PERMIT SET ,w:Etl[EIVE ITT 01F TUMILA M4.4 2016-11-00 FAN #2 A1 -D.250 -G10 - HEATER (MUA-1) 1. DIRECT GAS FIRED HEATED MAKE UP AIR UNIT WITH 10" BLOWER 2. INTAKE HOOD WITH EZ FILTERS 3. DOWN DISCHARGE - AIR FLOW RIGHT -> LEFT 4. COOLING INTERLOCK RELAY. 24VAC COIL. 120V CONTACTS. LOCKS OUT BURNER CIRCUIT VA HEN AC IS ENERGIZED. 5. MOTORIZED BACK DRAFT DAMPER 16" X 18" FOR SIZE 1 STANDARD & MODULAR DIRECT FIRED HEATERS W/EXTENDED SHAFT, STANDARD GALVANIZED CONSTRUCTION, 3/4" REAR FLANGE, LF120S ACTUATOR INCLUDED 6. LOW FIRE START. ALLOWS THE BURNER CIRCUIT TO ENERGIZE WHEN THE MODULATION CONTROL IS IN A LOW FIRE POSITION. 7. GAS PRESSURE GAUGE, 0-3511,2.511 DIAMETER, 1/4" THREAD SIZE 8. GAS PRESSURE GAUGE, -5 TO +15 INCHES WC., 2.5" DIAMETER, 1/4" THREAD SIZE 9. EXTRA SET OF V -BELTS. ONLY TO BE ORDERED AS FAN OPTION AT TIME FAN IS ORDERED. 10. SEPARATE 120VAC WIRING PACKAGE FOR MAKE-UP AIR UNITS. OPTION MUST BE SELECTED WHEN MOUNTING VFD IN PREWIRE PANEL OR WITH DCV PACKAGE. PROVIDES SEPARATE 120VAC INPUT TO SUPPLY FAN. THIS 120V SIGNAL MUST BE RIJN BY ELECTRICIAN FROM DCV TO MUA SWITCH. LIFTING LUG 20" EQUIPMENT CURB �[ /STED; 273/811 59/1611 CURB OUTER WALL DISCHARGE OPENING 131/411 37/811 293/411 If 161/4 " 20 161/411 2111 No ROOF OPENING 2" SMALLER THAN CURB DIMENSION. L__ FLEX CONDUIT FOR FIELD WIRING 32 1/811 AIRFLOW fMMMMMSERVI DISCONNE SWIT BLOWER/MOTOF ACCESS DOOR 24" SERVICE 'CLEARANCE RE( e SUPPLY SIDE HEATER INFORMATION: WINTER TEMPERATURE = 0°F. TEMP. RISE = 65°F. BTUs CALCULATED OFF ACTUAL AIR DENSITY OUTPUT BTUs AT ALTITUDE OF 0.0 ft. = 120666 INPUT BTUs AT ALTITUDE OF 0.0 ft. = 131159 71" Direct Fired (DF) Profile Plate Assembly Direct Fired Profile Plate Specifications: Description: Direct fired burners shall have patented (US Patent No.: US6629523132), self-adjusting profile plates designed to ensure proper air velocity and pressure drop across the burner. Profile plates shall allow burners to achieve clean combustion by limiting by-product levels to a maximum of 5ppm of carbon monoxide (CO), and 0.5ppm of nitrogen dioxide (NO2). Application: Spring-loaded burner profile plates are engineered to automatically react to the momentum of a fresh air stream, without the need for any motors or actuators to mechanically adjust them. With this feature, all DF units are designed for demand control ventilation (DCV) requirements. Certifications: All profile plate assemblies shall be included in the DF unit's ETL listing and comply with combined safety standards ANSI Z83.4 and CSA 3.7 (non -recirculating DF heaters) and ANSI Z83.18 (recirculating DF heaters). General Construction: -Profile plates shall be formed from G90 galvanized steel. -Profile plates shall vary in size per unit. -Profile plates shall be mounted along the same plane as the discharge of the burner. -Design shall incorporate properly torqued, permanently mounted spring hinges. -Spring hinges shall be made from plated steel. BUILT ( ® IN ACCORDANCE WITH CUP) NFPA No. 96 0 [ /STE0 US Wertek � ➢ �3 x kb MRMw- r , e }� JOB Tokyo Tokyo South Center Mall Crispy Town LOCATION SEATTLE, WA, 98188 N N O .DATE 6/29/2016 C JOB # 2682831 U IDTyG # 6 z .DR,I X/V BY Sean Elias coo -REV � OCR 'T SCALE 3/811 a) 't a> N E IT A^ N > COO < < (6 (6 In 0000 N N N N .3 N J J Q _ N N O O C U N U FLO z 00 3 coo W � OCR 'T N M a) 't a> N E -C 0- N N > COO < < (6 (6 In 0000 N N N N .3 J o TA $� r ERM 4-22-17 (4� U) W C Z W LL ts O 0 P®I Q THIS DRAWING DATA AND DESIGNS THEREON SHALL NOT BE DUPLICATED, USED OR DISCLOSED TO OTHERS FOR PROCUREMENT OR OTHER PURPOSE, EXCEPT AS OTHERWISE AUTHORIZED BY CONTRACT, WITHOUT PERMISSION OF JET INDUSTRIES, INC. 1935 SILVERTON RD. SALEM, OR 97301 TEL: (503) 363.2334 FAX: (503) 363.2622 OR CCB#16 3944,156944,158633,166248,17C982 ALL REPRODUCTIONS SHALL BEAR THIS � J J Q _ O LJ,J W 00 a_p O rL d' D z 00 W O N Q -z J ,17 U)'S U M � = F_ Q 0— DATE IISSUE 07.20.16 PERMIT SET CIy jut 2 8"2315 P&MIT CENTER M4.5 2016-11-00 FAN #1 DU180HFA - EXHAUST FAN (KEX-1) DUCTWORK BETWEEN EXHAUST RISER ON HOOD AND FAN (BY OTHERS) - DIRECT DRIVE CONSTRUCTION (NO BEL -S/PULLEYS) - ROOF MOUNTED FANS - RESTAURANT MODEL - UL705 AND UL762 - VARIABLE SPEED CONTROL - INTERNAL WIRING -WEATHERPROOF DISCONNECT -THERMAL OVERLOAD PROTECTION (SIN, 3LE PHASE) - HIGH HEAT OPERATION 300°F (149°C) - GREASE CLASSIFICATION TESTING NORMAL TEMPERATURE TEST EXHAUST FAN MUST OPERATE CONTINUOUSLY WHILE EXHAUSTING AIR AT 300°F (149°C) UNTIL ALL FAN PARTS HAVE REACHED THERMAL EQUILIBRIUM, AND WITHOUT Al JY DETERIORATING EFFECTS TO THE FAN V\ HICH WOULD CAUSE UNSAFE OPERATION. ADKIr%0 fiA1 171 Aon 1 ID T1=0T EXHAUST FAN MUST OPERATE CONTINUOUSLY WHILE EXHAUSTING BURNING GREASE V, �PORS AT 600°F (316°C) FOR A PERIOD OF 15 MINUTES WITHOUT THE FAN BECOMIN DAMAGED TO ANY EXTENT THAT COULD t:AUSE AN UNSAFE CONDITION. nPTIC)N.q GREASE BOX FAN BASE CERAMIC SEAL. - FOR GREASE DUCTS 10 Ioa C �09�1,"TSDUs Ince tek A VENTED CURB !0 GAUGE )TEEL ;ONSTRUCTION ROOF OPENING 24 DIMENSIONS 24 PITCHED CURBS ARE AVAILABLE FOR PITCHED ROOFS. SPECIFY PITCH: EXAMPLE: 7/12 PITCH = 30° SLOPE `VA Ai lMW BUILT e . IN s ACCORDANCE WITH N PA No. 96�aa ,�u C;.'>�, �A;�<•,,`t~j a't'': €t3�m'a _ ,_ N 2682831 T_ BY Sean Elias T- 11-011 3/811 N N OO IR C CO U N 4 -� U Lc o U_ C CO O Rf�ooNL o U N LO cu °�1=QNB' E .0 CL0 3: CO(O 0 Co 0 $�N CUNN.3 cuN 5LoC0a:a) o EXPn= 4-22-17 oca 2682831 .D.RATYN BY Sean Elias SCAZ 11-011 3/811 0 IR U) wti,. t,FJ.•_ CL r4 w 'A Lc o U_ o w z o ..,., O 0 0 Q W THIS DRAWING DATA AND DESIGNS THEREON SHALL NOT BE DUPLICATED, USED OR DISCLOSED TO OTHERS FOR PROCUREMENT OR OTHER PURPOSE, EXCEPT AS OTHERWISE AUTHORIZED BY CONTRACT, WITHOUT PERMISSION OF JET INDUSTRIES, INC. 1935 SILVERTON RD. SALEM, OR 97301 TEL: (503) 363.2334 FAX: (503) 363.2622 OR CCB#'S 3944,156944,158633,166248,17C982 ALL REPRODUCTIONS SHALL BEAR THIS NOTICE. JOB Tokyo Tokyo South Center Mall Crispy Town LOCATION SEATTLE, WA, 98188 -DATE 6/29/2016 _DX0 # 5 REV. JOB # 2682831 .D.RATYN BY Sean Elias SCAZ 11-011 3/811 wti,. t,FJ.•_ :RTY• UE TPKWILA M4.6 2016-11-00 ER TEMPE v I I I SECURE TO WALL WITH 4 SCREWS —\ \ ROOM TEMPERA' SENSOR AT -5 CONNECTION ON REVERSE. ONNECTED TO HOOD CONTROL ANEL. OUNTS IN STANDARD DOUBLE ANG JUNCTION BOX HOOD LIGHTS CASHMI INTERFACE. rW fs 1 CT. . 0 2917, WALL MOUNTED CONTROL CENTER N J J Q R- VE rn O O •"= O N C � U tc -c FL O N = >% 0O .D)vc # 10 0 co 't 0) cq LO N C Q N0-)L� cc N0 N (0NaaID��Dr-oo SC4Z 7 3/811=11-011 �Cq �NN.� n C7 (/) L L 4-: N WA so c EXPM 4-22-17 0 W O O. W W :b V THIS DRAWING DATA AND DESIGNS THEREON SHALL NOT BE DUPLICATED, USED OR DISCLOSED TO OTHERS FOR PROCUREMENT OR OTHER PURPOSE, EXCEPT AS OTHERWISE AUTHORIZED BY CONTRACT, WITHOUT PERMISSION OF JET INDUSTRIES, INC. 1935 SILVERTON RD. SALEM, OR 97301 TEL: (503) 363.2334 FAX: (503) 363.2622 OR CCBVS 3944,156944,158633,166248,17C982 ALL REPRODUCTIONS SHALL BEAR THIS J J J Q R- VE rn _ Q CI OF TUKAVILA O ~W WI-- 00 4t .D)vc # 10 V-- � cq U-5 - W UQ� N REV. SC4Z 7 3/811=11-011 Q i' M4 7 -z ■ ■ _ O�J W M < T— I— 0— DATE ISSUE 07.20.16 PERMIT SET JOB Tokyo Tokyo South Center Mall Crispy Town R- VE D LOCATION SEATTLE, WA, 98188 CI OF TUKAVILA .DATE 6/29/2016 JOB # 2682831 .D)vc # 10 .DR4 TVN BY Sean Elias PE U-5 - 7R REV. SC4Z 7 3/811=11-011 y �S r M4 7 e jY9 i411 ■ ■ 2016-11-00 PLUMBING FIXTURE SCHEDULE VALVE, GENERAL AFF CONNECTION SIZE W V CW HW SYMBOL DESCRIPTION COTG CLEANOUT: SIOUX CHIEF 834-4DNR 3" --- --- --- F_ ABS ADJ ROUGH IN CLEANOUT W/PLUG. CD CONDENSATE DRAIN q -o) FS -1 FLOOR SINK: .� Q- � N (oU PRESSURE REDUCING Q¢ (DtoN co o o �04 MNN.� 12X12X6 PORCELAIN WITH ACID RESISTANT COATING INTERIOR CONT. CONTINUATION V♦♦r J CHECK VALVE COTG 2" 12X12X6 ENAMEL FLR SINK W/STRAINER. BASIS OF DESIGN: PROFLO PF906K 2" 2" 1/2" --- ���-- 3" 12X12X6 ENAMEL FLR SINK W/STRAINER. BASIS OF DESIGN: PROFLO PF906M 3" 2" 1/2" --- TD-1 TROUGH DRAIN: 3" 2" --- --- W 12" x 36" 304 STAINLESS STEEL DRAIN, WITH ST. ST. GRATE, 4" DEPTH. 3" OUTLET, WITH TRAP. PRIMER AND (E) EXISTING —�{ BALANCING VALVE 2" VENT. (D H EL ELEVATION M W BASIS OF DESIGN: ADVANCE TABCO FTG -1236 ELECT ELECTRICAL 0 MV -1 MIXING VALVE: POINT OF USE, UNDERCOUNTER --- --- 1/2" 1/2" BASIS OF DESIGN: POWERS HYDROGUARD SERIES LFLM495 FPM FEET PER MINUTE 0) PIPE DROP RPBP-1 REDUCED PRESSURE BACKFLOW PREVENTER: --- --- 1/2" --- STRAINER, BALL VALVE SHUT -OFFS, UNIONS, AIR GAP FUNNEL FITTING. GAL WATTS LF009-S-QT, WATTS 909AGC AIR GAP. - TEE DOWN ON PIPE GPH GALLONS PER HOUR ALUMINUM— PIPE COVER. LAP SEALANT. STAINLESS STEEL CLAMPING STRAP. ROOF DECK.-` \ NOTE: USE ROOF MEMBRANE MANUFACTURER'S MATERIALS. PATCH AND REPAIR ROOF TO COMPLY WITH ALL ROOF WARRANTIES. 1 PIPE/CONDUIT COVER PEKE NO SCALE CONCRETE SLAB ON GRADE SAND VAPOR BARRIER ROCK FILL 3 FLOOR SINK NO SCALE T RATIO N FLOOR SINK SEALANT ALL AROUND FINISHED FLOOR FLOOR FINISH WHERE OCCURS SECOND LAYER 4'-0" SQUARE VAPOR BARRIER TIGHTLY FITTED AROUND PENETRATION AND SEALED WITH TAPE. _" VENT PIPE TO EXTERIOR PER LISTING UNION DRIP LEG MUST BE LOCATED AT � CHANGE OF FLOW DIRECTION GAS COCK APPLIANCE REGULATOR FLEXIBLE APPLIANCE CONNECTION PER CODE TO GAS TRAIN, SIZE PER O.M.S.C. TABLE 1309.1.2(2) AND LISTED FOR THIS USE. DORMONT 50 OR 60 SERIES _----GAS COCK WITH PILOT TAP WHERE REQUIRED -PILOT REGULATOR WHERE REQUIRED TE: T PLUG /-.SECONC ARV PRESSURE REGULATOR ARE OOOJ����6" DIRT LEG REQUIR =D FOR SERVICE PRESSURES EXCEED NG 7" WATER COLUMN (STANDARD "-APPLIANCE SERVICE PRESSU RE). SEE DRAWINGS FOR ADDITIONAL BRANCH PIPING INFORM, kTION. GAS APPLAINCE CONNECTION 2 PIPING DETAIL NO SCALE PLUMBING SYMBOL LIST VALVES ABBREVIATIONS D4 VALVE, GENERAL AFF ABOVE FINISHED FLOOR PLUMBING - DEMO PLAN - UNDERGROUND BFP BACKFLOW PREVENTER I>?<I— CONTROL VALVE PLUMBING - FLOOR PLAN - DOMESTIC U Irz 0- O f t• ' BFF BELOW FINISHED FLOOR F_ GATE VALVE CD CONDENSATE DRAIN q -o) CL CENTERLINE .� Q- � N (oU PRESSURE REDUCING Q¢ (DtoN co o o �04 MNN.� VALVE CONT. CONTINUATION V♦♦r J CHECK VALVE COTG CLEAN OUT TO GRADE \ J CV CHECK VALVE ���-- QUARTER TURN VALVE Ww CW COLD WATER D�4-- GLOBE VALVE DIA DIAMETER W Z (E) EXISTING —�{ BALANCING VALVE N (D H EL ELEVATION M W FITTINGS ELECT ELECTRICAL 0 FC FLEXIBLE CONNECTOR PIPE RISE U M FPM FEET PER MINUTE 0) PIPE DROP FPS FEET PER SECOND DATE 1 FT FEET TEE UP ON PIPE GAL GALLONS - TEE DOWN ON PIPE GPH GALLONS PER HOUR GPM GALLONS PER MINUTE CONTINUATION HD HEAD 2 CAP HP HEAT PUMP HP HORSE POWER PIPE BELOW GRADE HTG HEATING HOSE BIBB HTR HEATER HW HOT WATER PUMP HWR HOT WATER RETURN WCO -i WALL CLEANOUT ID INSIDE DIAMETER IE INVERT ELEVATION � CO FLOOR CLEANOUT IN INCHES FLOOR DRAIN LBS. POUNDS ❑® AREA DRAIN MH MOUNTING HEIGHT MIN MINIMUM O ROOF DRAIN MW MAKE-UP WATER ® FLOOR SINK (N) NEW t4� VENT THROUGH ROOF N/A NOT APPLICABLE -< OVERFLOW NOZZLE NIC NOT IN CONTRACT NO. NUMBER PIPING SYSTEMS NTS NOT TO SCALE - COLD WATER PIPING OC ON CENTER OD OUTSIDE DIAMETER - - HOT WATER PIPING P PUMP - - - HOT WATER RETURN PD PRESSURE DROP PIPING PRV PRESSURE REDUCING VALVE G GAS PIPING PSI POUNDS PER SQUARE INCH MPG MEDIUM PRESSURE GAS PIPING (2#) QTY QUANTITY D CONDENSATE PIPING (R) REMOVE (RL) RELOCATE PW PUMPED WASTE RET RETURN SANITARY PIPING BELOW SF SQUARE FEET GRADE OR FINISHED FLOOR SOV SHUT OFF VALVE SP STATIC PRESSURE SANITARY PIPING ABOVE GRADE OR FINISHED TEMP TEMPERATURE FLOOR TP TOTAL PRESSURE SD STORM DRAIN PIPING V VENT ABOVE GRADE OR FINISHED FLOOR VEL VELOCITY VTR VENT THROUGH ROOF — —SD— — STORM DRAIN PIPING BELOW GRADE OR W/ WITH FINISHED FLOOR WC WATER COLUMN ------------- SANITARY VENT PIPING W/O WITHOUT WT o- � SHEET INDEX P0.1 PLUMBING - LEGEND / SHEET INDEX / DETAILS T_ P1.1 PLUMBING - DEMO PLAN - UNDERGROUND P2.1 PLUMBING - FLOOR PLAN - SANITARY (D D P3.1 PLUMBING - FLOOR PLAN - DOMESTIC U Irz 0- O f t• ' F_ 0 q -o) o ` "O� E .� Q- � N (oU N Q¢ (DtoN N T_ T_ a) 0 (D D � C U Irz 0- O N F_ 0 q -o) o ` "O� E .� Q- � N (oU N Q¢ (DtoN co o o �04 MNN.� Lo Co Q ,;-: ai �), I FF0 04 RA g4, 13p� ' V`y9AL� EaM 4-22-17 cm fir/ W � �o u. y co ❑z W F_ O s o z 0 J C ❑ m �o Lu �- THIS DRAWING DATA AND DESIGNS THEREON SHALL NOT BE DUPLICATED, USED OR DISCLOSED TO OTHERS FOR PROCUREMENT OR OTHER PURPOSE, EXCEPT AS OTHERWISE AUTHORIZED BY CONTRACT, WITHOUT PERMISSION OF JET INDUSTRIES, INC. 1935 SILVERTON RD. SALEM, OR 97301 TEL: (503) 363.2334 FAX: (503) 363-8008 OR CCB#'8 3944,156944,158633,166248,17C982 ALL REPRODUCTIONS SHALL BEAR THIS NOTICE. x W 0 Z F_ W TW V♦♦r J \ J z J Q Ww O O (D W 00 ooc) W Z � o ' W UQ"I N (D H 'S O M W p Q z 0 J W U M D Q T_ F_ n.. DATE 1 ISSUE _ 07.20.16 PERMIT SET CITY OF TUHW PTI-RIVIIT CENTER P0.1 2016-11-00 55 55.3 AREA NOT IN SCOPE 56 56.6 GENERAL NOTES 1. EXISTING SANITARY WASTE AND GREASE WASTE PIPING TO BE SAWCUT AND REMOVED. SEE SHEET P2.1 FOR EXISTING PIPING TO STAY. 2. MINIMIZING SAWCUTTING AS MUCH AS POSSIBLE. 9X2' THICK SLAB WITH GRADE BEAMS AT COLUMN LINES. N C.2 ci o wU, 0 a= o t C i,., •, 1 �, yr; N C.2 ci o wU, 0 a= o � C U FL o cu LE o u. coo N � � 0 r U CV Lid av�QNOE m .0 Q-�NC00 N 64 QQ a0(0 ch 10 0000 �� �NN.�Lo m 131PII M 4-22-17 oco C.2 ci o wU, 0 W cc aam4 W LE o u. D Z uj cab w z oZ J 0 ti D o �x 0 � a m O ti �I E— coop V-- M N N WCL W UQ0') THIS DRAWING DATA AND DESIGNS THEREON SHALL NOT BE DUPLICATED, USED OR DISCLOSED TO OTHERS FOR PROCUREMENT OR OTHER PURPOSE, EXCEPT AS OTHERVNSE AUTHORIZED BY CONTRACT, WITHOUT PERMISSION OF JET INDUSTRIES, INC. 1935 SILVERTON RD. SALEM, OR 97301 TEL: (503) 363-2334 FAX: (503) 363-8008 OR CCB#'8 3944,156944,158833,166248,17C982 ALL REPRODUCTIONS SHALL BEAR THIS NOTICE. N W z z J 0 d 5 d-) O W O ti W E— coop V-- M N N W UQ0') C� ASO 00 _IO�J z U — W 0) M D Q v— F— 0 - DATE I ISSUE 07.20.16 1 PERMIT SET I Tx' OF TKWILA P1.1 2016-11-00 ER r.. AREA NOT IN SCOPE GENERAL NOTES 1. SLOPE ALL SANITARY PIPING 4" OR GREATER AT 1/8" PER FOOT, MINIMUM. 2. SLOPE ALL SANITARY PIPING 3" OR SMALLER AT 1/4" PER FOOT, MINIMUM. 3. SLOPE ALL GREASE WASTE PIPING 1/4" PER FOOT, MINIMUM. 4. SEE PLUMBING FIXTURE SCHEDULE FOR SIZE OF BRANCH PIPING SERVING EACH FIXTURE. 5. SEE KITCHEN PLANS FOR PLUMBING CONNECTIONS SIZES AND LOCATIONS TO KITCHEN EQUIPMENT. 6. FLOOR DRAINS AND FLOOR SINKS REQUIRE TRAP PRIMERS. NOTES OEXISTING FLOOR SINK TO REMAIN. O2 2" COPPER MANIFOLD INDIRECT WASTE FROM EACH - CT -03 BAIN MARIE WARMER, SLOPE AT 1/4"/FT, WITH UPPER END CLEANOUT, TERMINATE INDIRECT AT FLOOR SINK, COORDINATE WITH KITCHEN SUPPLIER. JMBING - FLOOR PLAN - SANITARY AREA NOT IN SCOPE N W�' L:3 E C U v W caU '�)111111*iY F0 cu U) co C O LoU W U c rn - N to (D c40O ca E CL '4 co N Q`S to � 0000 �j� CUN04 O Lo (A Q.: N E(PU ;4 4-22-17 acn 00 W�' �o cm Off- 0 v W Lucc o '�)111111*iY Z W U u - O O O 2 oa D tj.g "� m ..r W THIS DRAWING DATA AND DESIGNS THEREON SHALL NOT BE DUPLICATED, USED OR DISCLOSED TO OTHERS FOR PROCUREMENT OR OTHER PURPOSE, EXCEPT AS OTHERWISE AUTHORIZED BY CONTRACT, WITHOUT PERMISSION OF JET INDUSTRIES, INC. 1935 SILVERTON RD. SALEM, OR 97301 TEL: (503) 363.2334 FAX: (503) 363.8008 OR CCBW9 3944,156944,158833,166248,17C982 ALL REPRODUCTIONS SHALL BEAR THIS r,7, dz r n\ U) I z n� ii J LL m J VJ O W00 00 ~ WM 00 N UQ� z 0 - W c�Q F- 0 - DATE ISSUE 07.20.16 PERMIT SET RECEIVE C1l 1 Or JUL 2 8 2 ARMiT SP P2.1 /r� day pp pp yd/h ?tx r 2016-11-00 I AREA NOT IN SCOPE GENERAL NOTES 1. SEE PLUMBING FIXTURE SCHEDULE FOR SIZE OF BRANCH PIPING SERVING FIXTURES. 2. TRAP PRIMER PIPING NOT SHOWN FOR CLARITY. SEE SANITARY PLANS FOR TRAPS REQUIRING TRAP PRIMERS. 3. LOCATE VALVES IN AN ACCESSIBLE LOCATION. NOTES OEXISTING 3/4" 21b GAS UP. O2 21b STANDARD PRESSURE GAS REGULATOR, VENT TO EXTERIOR PER MANUFACTURERS LISTING. OAUTOMATIC GAS SHUT-OFF, TO SHUT OFF GAS SUPPLY IN THE CASE OF FIRE, INTERTIE TO HOOD FIRE SUPPRESSION SYSTEM, MANUAL RETURN TO OPEN. O4 MUA-3 ON ROOF. EXTEND 1/2" 21b GAS TO MUA-3 21b TO 7" W.C. REGULATOR, 3/4" STD PRESSURE GAS CONNECTION WITH GAS VALVE, AND CONNECTION. IN WALL JMBING - FLOOR PLAN - DOMESTIC 1-011 AREA NOT IN SCOPE AREA NOT IN SCOPE } J Tt ��' &t Ll ficT 0 �c s x SI',� a , N 0 N cn N � O � U v _� D- o ca U rn � mt m t 04 Lo cu oQNa' E :L .a a N (D N QQa)(6CDU) J Co=oo �j NM N N. 3 ry J Q y RA g i" Q' ONAL EXKW 4-22-17 THIS DRAWING DATA AND DESIGNS THEREON SHALL NOT BE DUPLICATED, USED OR DISCLOSED TO OTHERS FOR PROCUREMENT OR OTHER PURPOSE, EXCEPT AS OTHERWISE AUTHORIZED BY CONTRACT, WITHOUT PERMISSION OF JET INDUSTRIES, INC. 1935 SILVERTON RD. SALEM, OR 97301 TEL: (503) 363.2334 FAX: (503) 363.8008 OR CCEIVS 3944,156944,158633,166248,17C982 ALL REPRODUCTIONS SHALL BEAR THIS 2 0 f) I z Q J Q— J ry J Q � 0 75 O O w00� -= LL F— r— N c) W0) U Q N 0) (D -r 3: m � �z _l 0�� U) S U Q T -F -n DATE ISSUE _ 07.20.16 PERMIT SET IT OF- T 'ERMIT Ci -LATER P3.1 2016-11-00