Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Permit D16-0226 - KLAIBER RESIDENCE - DECK REPLACEMENT
KLAJBER DECK 13020 35TH AVE S EXPIRED 03/08/17 D16-0226 Parcel No: Address: Project Name: City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-438-9350 Web site: http://www.TukwilaWA.eov DEVELOPMENT PERMIT 7359600830 Permit Number: D16-0226 13020 35TH AVE S KLAIBER DECK Issue Date: 8/5/2016 Permit Expires On: 2/1/2017 Owner: Name: Address: Contact Person: Name: Address: Contractor: Name: Address: License No: Lender: Name: Address: KLAIBER JILL A 13020 35TH AVE S , TUKWILA, WA, 98168 JILL KLAIBER 13020 35 AVE S , TUKWILA, WA, 98168 AFFIDAVIT - JILL KLAIBER Phone: (425) 774-1541 Phone: Expiration Date: DESCRIPTION OF WORK: REPLACE EXISTING DECK, 4 FT X 7 FT - 28 SQ FT Project Valuation: $220.08 Type of Fire Protection: Sprinklers: Fire Alarm: Type of Construction: VB Electrical Service Provided by: TUKWILA Fees Collected: $72.75 Occupancy per IBC: U Water District: 125 Sewer District: VALLEY VIEW Current Codes adopted by the City of Tukwila: International Building Code Edition: International Residential Code Edition: International Mechanical Code Edition: Uniform Plumbing Code Edition: International Fuel Gas Code: 2015 2015 2015 2015 2015 National Electrical Code: WA Cities Electrical Code: WAC 296-46B: WA State Energy Code: 2014 2014 2014 2015 Public Works Activities: Channelization/Striping: Curb Cut/Access/Sidewalk: Fire Loop Hydrant: Flood Control Zone: Hauling/Oversize Load: Land Altering: Landscape Irrigation: Sanitary Side Sewer: Sewer Main Extension: Storm Drainage: Street Use: Water Main Extension: Water Meter: Volumes: Cut: 0 Fill: 0 Number: 0 No Permit Center Authorized Signature: Date: I hearby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this development permit and agree to the conditions attached to this permit. Sign(a't Print Nme:Ar U,(_,(M Date:i •lco This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: ***BUILDING PERMIT CONDITIONS*** 2: Work shall be installed in accordance with the approved construction documents, and any changes made during construction that are not in accordance with the approved construction documents shall be resubmitted for approval. 3: All permits, inspection record card and approved construction documents shall be kept at the site of work and shall be open to inspection by the Building Inspector until final inspection approval is granted. 4: All construction shall be done in conformance with the Washington State Building Code and the Washington State Energy Code. 5: All construction noise to be in compliance with Chapter 8.22 of the City of Tukwila Municipal Code. A copy can be obtained at City Hall in the office of the City Clerk. 6: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 1700 BUILDING FINAL** 0409 FRAMING 0104 REMOVE STOP WORK CITY OF TUKh-.LA Community Development Department Public Works Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.TukwilaWA.gov Building Permit No. Project No. Date Application Accepted: Date Application Expires: For o ace use on CONSTRUCTION PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **Please Print** SITE LOCATION Site Address: Tenant Nam 4r, King Co Assessor's Tax No.: 3 2 3S rliN Ate_ Tt4eitAhre, PROPERTY OWNER Name if( 1//C, _ L, ._ _ r1.t�/v I v Y Company Name: Name,' 1 Ki- Address: City'—j iA,0t (6, SV`i%- Addresy „)0 3st 8)?,:,6, s MGIC CityrTl vi, itt, S� 4 f) i' ip:(.,,A CONTACT PERSON — person receiving all project communication Name if( 1//C, _ L, ._ _ r1.t�/v I v Y Company Name: Addrest:,1/`�f79t�( Address: City'—j iA,0t (6, SV`i%- ` 8)?,:,6, Phon4 25. 11 e+ 1 S 4 Flax: MGIC Zip: Email: "/44 Fax: City: GENERAL CONTRACTOR INFORMATION Company me: 'vA ,o ; I v Y Company Name: t v / A Address: Architect Name: City: State: Address: Zip: Phone: Fax: City: Contr Reg No.: Zip: Exp Date: Tukwila Business License No.: Email: H.\Applications\Forms-Applications On Line\2012 ApplicationsTermit Application Revised - 2-7-12.docx Revised: February 2012 bh Suite Number: Floor: New Tenant: ❑ Yes Et..75-o ARCHITECT OF RECORD Name: I v Y Company Name: t v / A Address: Architect Name: City: Address: Zip: City: State: Zip: Phone: Fax: Email: ENGINEER OF RECORD Name: I v Y Company Name: r > j iq I� Address: Engineer Nam : City: Address: Zip: City: State: Zip: Phone: Fax: Email: LENDER/BOND ISSUED (required for projects $5,000 or greater per RCW 19.27.095) Name: I v Y Address: City: State: Zip: Page 1 of 4 BUILDING PERMIT INFORMATI( 206-431-3670 Valuation of Project (contractor's bid price): $ M/0 0 Existing Building Valuation: $ Describe the scope of work (please provide detailed information): Ng letCji/ �''1 t-ftYL 10 dec / piaci Will there be new rack storage? ❑ ....Yes h'- If yes, a separate permit and plan submittal will be required. Provide All Building Areas in Square Footage Below PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact: Handicap: Will there be a change in use? ❑ Yes ❑ No If "yes", explain: FIRE PROTECTION/HAZARDOUS MATERIALS: 0 Sprinklers 0 Automatic Fire Alarm ❑ None 0 Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes 0 No If `yes', attach list of materials and storage locations on a separate 8-1/2" x 11 " paper including quantities and Material Safety Data Sheets. SEPTIC SYSTEM 0 On-site Septic System — For on-site septic system, provide 2 copies of a current septic design approved by King County Health Department. H:\Applications\Forms-Applications On Line \2012 Applications'Permit Application Revised - 2-7-12.docx Revised: February 2012 bh Page 2 of 4 Existing Interior Remodel Addition to Existing Structure New Type of Construction per IBC Type of Occupancy per IBC 1St Floor 2nd Floor 3rd Floor Floors thru Basement Accessory Structure* Attached Garage Detached Garage Attached Carport Detached Carport Covered Deck Uncovered Deck PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact: Handicap: Will there be a change in use? ❑ Yes ❑ No If "yes", explain: FIRE PROTECTION/HAZARDOUS MATERIALS: 0 Sprinklers 0 Automatic Fire Alarm ❑ None 0 Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes 0 No If `yes', attach list of materials and storage locations on a separate 8-1/2" x 11 " paper including quantities and Material Safety Data Sheets. SEPTIC SYSTEM 0 On-site Septic System — For on-site septic system, provide 2 copies of a current septic design approved by King County Health Department. H:\Applications\Forms-Applications On Line \2012 Applications'Permit Application Revised - 2-7-12.docx Revised: February 2012 bh Page 2 of 4 CUBLIC WORKS PERMIT INFO :ATION — 206-433-0179 Scope of Work (please provide detailed information):; P(C .k1St4-l41 Pv 146/ Call before you Dig: 811 Please refer to Public Works Bulletin #1 for fees and estimate sheet. Water District ❑ .. Tukwila ❑ ...Water District # 125 ❑ .. Water Availability Provided Sewer District ❑ .. Tukwila 0 .. Sewer Use Certificate ❑...Valley View ❑ ...Sewer Availability Provided ❑... Highline ❑ ... Renton ❑... Renton ❑... Seattle Septic System: O On-site Septic System — For on-site septic system, provide 2 copies of a current septic design approved by King County Health Department. Submitted with Application (mark boxes which apply): 0 .. Civil Plans (Maximum Paper Size — 22" x 34") ❑ .. Technical Information Report (Storm Drainage) 0 .. Bond 0...Insurance ❑... Easement(s) Proposed Activities (mark boxes that apply): ❑ .. Right-of-way Use - Nonprofit for less than 72 hours ❑ .. Right-of-way Use - No Disturbance ❑ .. Construction/Excavation/Fill - Right-of-way 0 Non Right-of-way ❑ 0 .. Total Cut ❑ .. Total Fill cubic yards cubic yards ❑ .. Sanitary Side Sewer ❑ .. Cap or Remove Utilities 0 .. Frontage Improvements ❑ .. Traffic Control O .. Backflow Prevention - Fire Protection Irrigation Domestic Water ❑• ❑. ❑. ❑. D... Geotechnical Report 0... Maintenance Agreement(s) ❑ .. Traffic Impact Analysis ❑ .. Hold Harmless — (SAO) ❑ .. Hold Harmless — (ROW) 0... Right-of-way Use - Profit for less than 72 hours 0... Right-of-way Use — Potential Disturbance 0... Work in Flood Zone 0...Storm Drainage .. Abandon Septic Tank .. Curb Cut .. Pavement Cut .. Looped Fire Line If 0 .. Permanent Water Meter Size (1) ❑ .. Temporary Water Meter Size (1) 0 .. Water Only Meter Size ❑ .. Sewer Main Extension Public ❑ 0 .. Water Main Extension Public 0 31 WO # WO # WO # Private 0 Private ❑ ❑ ... Grease Interceptor ❑ ... Channelization ❑...Trench Excavation 0...Utility Undergrounding (2) " WO# (3) " WO# (2) " WO # (3) " WO # ❑ .. Deduct Water Meter Size FINANCE INFORMATION Fire Line Size at Property Line Number of Public Fire Hydrant(s) 0 .. Water ❑ .. Sewer ❑ .. Sewage Treatment Monthly Service Billing to: Name: Mailing Address: Day Telephone: Water Meter Refund/Billing: Name: Mailing Address: City State Zip Day Telephone: City State Zip H:Wpplications\Forms-Applications On Line\2012 Applications\Permit Application Revised - 2-7-12.docx Revised: February 2012 bb Page 3 of 4 PERMIT APPLICATION NOTES — Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING 1 WNER ORUTH Signat _ : RIZED AGENT: Prin Qy, Mailing Address: 35 c�V 3 S 461aw- H:\Applications\Forms-Applications On Line\2012 Applications\Permit Application Revised - 2-7-I2.docx Revised: February 2012 bh Date: 1 l 7q /G P Day Telephone: 425 7) q 15i 1 U lAjA lv8 City State Zip Page 4 of 4 Cash Register Receipt City of Tukwila DESCRIPTIONS PermitTRAK I ACCOUNT 1 QUANTITY I PAID $72.75 D16-0226 Address: 13020 35TH AVE S Apn: 7359600830 $72.75 DEVELOPMENT $69.50 PERMIT FEE R000.322.100.00.00 0.00 $65.00 WASHINGTON STATE SURCHARGE B640.237.114 0.00 $4.50 TECHNOLOGY FEE $3.25 TECHNOLOGY FEE TOTAL FEES PAID BY RECEIPT: R9138 R000.322.900.04.00 0.00 $3.25 $72.75 Date Paid: Friday, August 05, 2016 Paid By: JILL KLAIBER Pay Method: CREDIT CARD 715074 Printed: Friday, August 05, 2016 3:47 PM 1 of 1 CPSYSTEMS INSPECTION RECORD Retain a copy with permit INS ION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION (206) 431-3670 1776- 2-z-10 6300 Southcenter Blvd., #100, Tukwila. WA 98188 Permit Inspection Request Line (206) 438-9350 Project: k 1. q (t)bear- r- pe-� Type f Inspection:r 1 KEy o S �� (cry' 1, Address. /3° O 35-frk Alt , . Date Called: Special Instructions: Date Wanted:_ m: 61 -f -lb f_/o Ruest r: yy Rt (( 41 (Ct.( Phone No: � i-77t-frfs111 Approved per applicable codes. Corrections required prior to approval. COMMENTS: Date: ,)eiyi n REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. Inspector:A, Owner: Jill Klaiber 13020 35th Ave S Tukwila, WA Project: Rear deck remove and replace per City of Tukwila Deck handout (See Attached) ,;, R'' /a ; e r /3020 3Sly ,¢ ✓e S. Tel /61; 11 4/ DECK PLAN & SIDE VIEWS City of Tukwila 2015 WASHINGTON STATE BUILDING CODES Building Division/Permit Center 6300 Southcenter Blvd. #100 Tukwila, WA 98188 (206) 431-3670 HOUSE TREATED WOOD DECK OR DECK COATING TOP 2X4 RAIL BEAM AND POST BELOW 1 TOP VIEW 3 LI L U I LI L LI NNNNIJUNN ( O LAN BALUSTERS (TYP.) CORNER POST TYP. FRONT VIEW 2X4 TOP AND BOTTOM RAIL TOP RAIL ONLY 9 9 a s � 9 = 4X BEAM / FINISH GRADE BELOW POST WHERE WOOD POST SHALL NOT COME INTO CONTACT WITH THE GROUND FOOTING AND CONCRETE PIER POST BASE SET IN CONCRETE 6 POST CAP TYP. CROSS BRACE AS REQUIRED ONE PIECE PIER BLOCK W/ POST BASE (SEE NOTE) CONCRETE FOOTING POST BASE SET IN CONCRETE MIN. 12" BELOW FINISH GRADE OPTIONAL RAILING CONSTRUCTION NO BOTTOM 2X4 RAIL DIFFERENT OPTIONS FOR POST AND PIER / CONSTRUCTION NOTE: DECK FOOTINGS SIZE VARY PER DECK SIZE AND WEIGHT. CHECK CODE REQUIREMENTS. (PIER BLOCK NOT ALLOWED FOR ATTACHED DECKS.) DRAWING # DCD H009 -F DATE 7/25/2016 (f a S- 3 `+a DECK ELEVATIONS DETAILS City of Tukwila 2015 WASHINGTON STATE BUILDING CODES Building Division/Permit Center 6300 Southcenter Blvd. #100 Tukwila, WA 98188 (206) 431-3670 NEW DECK CARAGE BOLT OR SCREWS GUARD RAIL 4X4 POST • • 3/8 MIN. BOLTS 0 SPACED TO NOT ALLOW PASSAGE OF A 4 INCH DIAMETER SPHERE z a s a a a NUT AND WASHERS 2'-0" EACH END MAXIMUM CANTILEVER POSITIVE CONNECTIONS REQUIRED POST BASE IN CONCRETE FOOTING ELEVATED TO PREVENT GROUND CONTACT. 5 — GUARD RAIL 36" TO 38" HIGH MAX. 3 6 S S 9 ® 6 s 7a a a a a n --><-11><i}‹. iwx (SEE CONNECTOR NOTE "B" -PAGE 3) JOIST HANGER BEAM SIZED FOR SPAN PER JOIST SIZE POST BEAM HARDWARE (POST CAPS) 4X4 MIN. POST FINISH GRADE FOOTING NOTE: *All support framing shall be pressure treated. (IRC R317.1 & SECTION R318) *Decking, railing balusters and hand rails shall be treated outdoor wood or similar. *Current chemical trcatmcnt for wood preservative will damage light galvanizing on bolts, nails and hangers. Usc hot dipped galvanizing, stainless steel or better. EXISTING HOUSE —0- BALUSTERS (TYP.) 2X FASTENED TO EXTERIOR WALL DECKING FLASH (SEE DETAIL BELOW) aL LAG BOLTS (SEE "A" -PAGE 3 LEDGER BOLT SIZE & SPACING) FLASH BEHIND SIDING AND BELOW DECKING FLASH BEHIND LEDGER SIDE VIEW DRAWING # DCD H009 -E DATE 7/25/2016 BAND JOIST 2 City of Tukwila 2015 WASHINGTON STATE BUILDING CODES Building Division/Permit Center 6300 Southcenter Blvd. #100 Tukwila, WA 98188 (206) 431-3670 NOTE: THIS DETAIL IS APPLICABLE WHERE FLOOR JOISTS ARE PARALLELTO DECK JOISTS. SHEATHING SIDING FLASHING FOR WATER TIGHTNESS DECKING APPROVED JOIST HANGERS 2x LEDGER WITH FASTENERS IN ACCORDANCE WITH TABLE R507.2 HOLD-DOWN DEVICE MIN 750 LB. CAPACITY AT4 LOCATIONS, EVENLY DISTRIBUTED ALONG DECK AND ONE WITHIN 2° OF EACH END OF THE LEDGER. HOLD-DOWN DEVICES SHALL FULLY ENGAGE DECK JOIST PER HOLD-DOWN MANUFACTURER. AFULLY THREADED '/e° DIAMETER LAG SCREW PREDRILLED W/ MIN. 3" PENETRATION TO CENTER OF TOP PLATE, STUDS, OR HEADER. FIGURE R507.2.3(2) DECK ATTACHMENT FOR LATERAL LOADS R507.2.4 Deck lateral load connection. The lateral load connection required by Section R507.1 shall be permitted to be in accordance with Figure R507.2.3(1) or R507.2.3(2). Where the lateral load connection is provided m accordance with Figure R507.2.3(1), hold-down tension devices shall be installed in not less than two locations per deck, within 24 inches of each end of the deck. Each device shall have an allowable stress design capacity of not less than 1,500 pounds (6672 N). Where the lateral load connections are provided in accordance with Figure R507.2.3(2), the hold-down tension devices shall be installed in not less than four locations per deck, and each device shall have an allowable stress design capacity of not less than 750 pounds (3336 N). Exception: Decks not more than 30 inchcs above grade at any point may be unattached 4 DRAWING # DCD H00 -C DATE 7/25/2016 BAND JOIST DETAILS City of Tukwila 2015 WASHINGTON STATE BUILDING CODES Building Division/Permit Center 6300 Southcenter Blvd. #100 Tukwila, WA 98188 (206) 431-3670 EXTERIOR SHEATHING EXISTING STUD WALL EXISTING 2x BAND JOIST OR ENGINEERED RIM BOARD FLOOR FRAMING EXISTING FOUNDATION WALL ter. 2" MIN. 1111....111%1 1-5/8" MIN. 5" MAX. 2" MIN. a O' C o . 04, .00 7 O , O 0 p. JOIST HANGER FIGURE R507.2.1(2) PLACEMENT OF LAG SCREWS AND BOLTS IN BAND JOISTS DECK JOIST LAG SCREWS OR BOLTS R507.2.2 Band joist details. Band joists attached by a ledger in accordance with Section R507.2 shall be a minimum 2 -inch -nominal (51 mm), solid -sawn, spruce -pine -fir lumber or a minimum 1 -inch by 91/2 -inch (25 mm ' 241 mm) dimensional, Douglas fir, laminated veneer lumber. Band joists attached by a ledger in accordance with Section R507.2 shall be fully supported by a wall or sill plate below. R507.2.3 Ledger to band joist fastener details. Fasteners used in deck ledger connections in accordance with Table R507.2 shall be hot -dipped galvanized or stainless steel and shall be installed in accordance with Table R507.2.1 and Figures R507.2.1(1) and R507.2.1(2).inches may be reduced to 3/4 inch when the band joist is directly supported by a mudsill, a header or by double top wall plates FLOOR SHEATHING NAILING AT 6" MAXIMUM ON CENTER TO JOIST WITH HOLD-DOWN HOLD-DOWN OR SIMILAR TENSION CE VICE 3 FLOOR JOIST) DECK JOIST FIGURE 507.2.3(1) DECK ATTACHMENT FOR LATERAL LOADS DRAWING # DCD H00 -C DATE 7/25/2016 .plILA wgsy 4 OZ Q v�2 1908 DECK HARDWARE INFO City of Tukwila 2015 WASHINGTON STATE BUILDING CODES Building Division/Permit Center 6300 Southcenter Blvd. #100 Tukwila, WA 98188 (206) 431-3670 DECK HARDWARE INFO TABLE R507.2 DECK LEDGER CONNECTION TO BAND JOISTa, b (Deck live load = 40 psf, deck dead load = 10 psf, snow load £ 40 psi) JOIST SPAN 6' and less 6'1"to8' 8'1"to10' 10'1" to 12' 12'1" to 14' 14'1" to 16' 16'1" to 18' Connection Details Connection Detailsd' e 1/2 inch diameter lag screw with 15/32 inch maximum sheathing a 30 23 18 15 13 11 10 1/2 inch diameter bolt with 15/32 inch maximum sheathing 36 36 34 29 24 21 19 1/2 inch diameter bolt with 15/32 inch maximum sheathing and 1/2 inch stacked washers b h 36 36 29 24 21 18 16 For SI: 1 inch = 25.4 mm, 1 foot = 304.8 mm. 1 pound per square foot = 0.0479 kPa. a. The tip of the lag screw shall fully extend beyond the inside face of the band joist. b. The maximum gap between the face of the ledger board and face of the wall sheathing shall be 1/22. c. Ledgers shall be flashed to prevent water from contacting the house band joist. d. Lag screws and bolts shall be staggered in accordance with Section R502.2.2.1.1. e. Deck ledger shall be minimum 2 x 8 pressure -preservative -treated No. 2 grade lumber, or other approved materials as established by standard engineering practice. f. When solid -sawn pressure -preservative -treated deck ledgers are attached to a minimum 1 inch thick engineered wood product (structural composite lumber, laminated veneer lumber or wood structural panel band joist), the ledger attachment shall be designed in accordance with accepted engineering practice. g. A minimum 1 x 91/2 Douglas Fir laminated veneer lumber rimboard shall be permitted in lieu of the 2 -inch nominal band joist. h. Wood structural panel sheathing, gypsum board sheathing or foam sheathing not exceeding 1 inch in thickness shall be permitted. The maximum distance between the face of the ledger board and the face of the band joist shall be 1 inch. R507.2.1 Ledger details. Deck ledgers installed in accordance with Section R507.2 shall be a minimum 2 -inch by 8 -inch (51 mm by 203 mm) nominal, pressure - preservative -treated southern pine, incised pressure -preservative -treated Hem -fir, or approved, naturally durable, No. 2 grade or better lumber. Deck ledgers installed in accordance with Section R507.2 shall not support concentrated loads from beams or girders. Deck ledgers shall not be supported on stone or masonry veneer. TABLE 507.2.1 PLACEMENT OF LAG SCREWS AND BOLTS IN DECK LEDGERS AND BAND JOISTS MINIMUM END AND EDGE DISTANCES AND SPACING BETWEEN ROWS TOP EDGE BOTTOM EDGE ENDS ROW SPACING Ledger a 2 inches d 3/4 inch 2 inchcsb 15/8 inches b Band Joist c 3/4 inch 2 inches e 2 inches 15/8 inches b For SI: 1 inch = 25.4 nun. a. Lag scrcws or bolts shall be staggered from b. Maximum 5 inches. c. For engineered rim joists, the manufacturer's d. The minimum distance from bottom row e. The 2 inches may be reduced to 3/4 inch the top recommendations of lag screws when the to thc bottom along thc horizontal run of the dcck ledger in accordance with Figure R507.2.1(1). shall govern. or bolts to the top edge of the ledger shall be in accordance with Figure R507.2.1(1). band joist is directly supported by a mudsill, a header or by double top wall plates z STAGGER FASTENERS IN 2 ROWS 5.5" MIN. FOR 2 :X 8' 'DISTANCE SHALL BE PERMITTED TO 5'M. • 0 4) 6.5 MIN. FOR 2X10 SE REDUCED TO4.5"IF LAG SCREWS 7.5" MIN. FOR 2 X 12 ARE USED OR SOLT SPACING IS ® 0 REDUCED TO THAT OF LAG SCREWS 2" MIN. TO ATTACH 2 X 8 LEDGERS TO 2 X 8 BAND JOISTS. LAG SCREW OR BOLT 3/4" MIN. LEDGER FIGURE R507.2.1(1) 2PLACEMENT OF LAG SCREWS AND BOLTS IN LEDGERS DRAWING # DCD H00 -B DATE 7/25/2016 SAMPLES OF DECK CONSTRUCTION 4/ Vis: 4�Z o L. City of Tukwila 2015 WASHINGTON STATE BUILDING CODES Building Division/Permit Center 6300 Southcenter Blvd. #100 Tukwila, WA 98188 190E (206) 431-3670 1 REQUIREMENTS FOR TYPICAL DECK CONSTRUCTION WITH PLAN DETAILS Q. When is a permit required for a residential deck? A. All decks require application for a building permit Q. What information is required to apply for a permit? A. Your proposed project must have reviewable deck plans. These plans must contain the following information checked below to be reviewable by the Building Department. Plans must be fully dimensioned or to scale Provide a site plan showing deck(s) in relation to property and setbacks Provide elevation drawing showing final grade of surrounding ground Show height of deck above finished grade Show deck -flooring type (wood, vinyl, etc) Show direction, size and spacing of all floor joists, posts and beams Show connections: post to beam, post to pad or foundation, identify fasteners and hardware as galvanized, identify hardware connections with specific type or manufactures hardware identification. Provide footing details including reinforcing bars size and footing dimensions Indicate method of attachment to house Show roof framing detail, roof covering (if applicable) Provide stair detail (rise, run, width, handrails) and guardrail details Show all wood as being treated or of natural resistance to decay PLEASE NOTE: Deck handouts are provide as a helpful reference only and are not to be used for permit plans. Deck plans shall be drawn specific to each site location and characteristics. DRAWING # DCD H009 -A DATE 7/25/2016 AUTHORIZATION FOR ALTERNATE PLAN SUBMITTAL (LIMITED SCOPE OF WORK) IBC & IRC Section 104.1 Date: g/S/-2 o/v Permit/Application Number: bila © p Address: /3 OzO 35214 Al/.e S Tukwila, WA 981 Description of Work: PG rM d de ref /a exist i j G/ X / Yea v a/e a d -Tv, Oe.cIL #arthof The above project permit applicant, due to the limited scope of work, is authorized to submit reduced plan requirements described below: 1. Complete permit application(s): yl Building Mechanical n Plumbing/Gas Piping 1 1 Electrical ❑ Other 2. Plan and/or Specification (minimum): Il Site Plan Cross Sections Floor Plan Elevations n Foundation Structural Calcs Roof Plan 1 1 Narrative Narrative WSEC Compliance 3. Required Inspections (only completed when to be issued over the counter): rr-� Framing ❑ Glazing Final j) Other: fW f4' ��.Jdw"k 4. Other Special Instructions: Authorized By: Printed Name: fit ✓717 Date: r,/s/-2 d/‘ (Authorization void 30 days after date) 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206 431-3670 • Fax: 206 431-3665 W:\Permit Center\Templates\Forms\Auth for Reduced Plan Submittal.docx 2/1/2017 City of Tukwila Department of Community Development JILL KLAIBER 13020 35 AVE S TUKWILA, WA 98168 RE: Permit No. D16-0226 KLAIBER DECK 1302035AVE S Dear Permit Holder: Allan Ekberg, Mayor Jack Pace, Director In reviewing our current records, the above noted permit has not received a final inspection by the City of Tukwila Building Division. Per the International Building Code, International Mechanical Code, Uniform Plumbing Code and/or the National Electric Code, every permit issued by the Building Division under the provisions of these codes shall expire by limitation and become null and void if the building or work authorized by such permit has not begun within 180 days from the issuance date of such permit, or if the building or work authorized by such permit is suspended or abandoned at any time after the work has begun for a period of 180 days. Your permit will expire on 3/8/2017. Based on the above, you are hereby advised to: 1) Call the City of Tukwila Inspection Request Line at 206-438-9350 to schedule for the next or final inspection. Each inspection creates a new 180 day period, provided the inspection shows progress. -or- 2) Submit a written request for permit extension to the Permit Center at least seven(7) days before it is due to expire. Address your extension request to the Building Official and state your reason(s) for the need to extend your permit. The Building Code does allow the Building Official to approve one extension of up to 180 days. If it is determined that your extension request is granted, you will be notified by mail. In the event you do not call for an inspection and/or receive an extension prior to 3/8/2017, your permit will become null and void and any further work on the project will require a new permit and associated fees. Thank you for your cooperation in this matter. Sincerely, Rachelle Ripley Permit Technician File No: D16-0226 6300 Southcenter Boulevard Suite #100 • Tukwila, Washington 98188 • Phone 206-431-3670 • Fax 206-431-3665 CITY OF TUKWILA Department of Community Development 6300 Southcenter Boulevard, Tukwila, WA 98188 Telephone: (206) 431-367o FAX (206) 431-3665 E-mail: tukplan@ci.tukwila.wa.us ci.tukwila.wa.us Permit Center/Building Division 206 431-3670 Public Works Department 206 433-0179 Planning Division 206 431-3670 AFFIDAVIT IN LIEU OF CONTRACTOR REGISTRATION STATE OF WASHINGTON) ) ss. COUNTY OF KING j( K [please print naLlir , states as follows: PERMIT NO: 1. I have made application for a permit from the City of Tukwila, Washington. 2. I understand that state law requires that all building construction contractors be registered with the State of Washington. The exceptions to this requirement are stated under Section 18.27.090 of the Revised Code of Washington, a copy of which is printed on the reverse side of this Affidavit. I have read or am familiar with RCW 18.27.090. 3. I understand that prior to issuance of a permit for work which is to be done by any contractor, the City of Tukwila must verify either that the contractor is registered by the State of Washington, or that one of the exemptions stated under RCW 18.27.090 applies. 4. In order to provide verification to the City of Tukwila of my compliance with this requirement, I hereby attest that after reading the exemptions from the registration requirement of RCW 18.27.090, I consider the work authorized under this permit to be exempt under number 13 , and will therefore not be performed by a registered contractor. 5. I understand that the licensing provision of RCW 19.28.161 through 19.28.271 shall not apply to persons making electrical installations on their own property or to regularly employed employees working on the premises of their employer. The proposed electrical work is not for the construction of a new building for rent, sale or lease. I understand that I may be waiving certain rights that I might otherwise have under state law in any decision to engage an unregistered contractor to perform construction work. LAURIEA. NOTARY PUBLICRIC STATE OF WASHINGTON COMMISSION EXPIRES MAY 29, 2018 r/Owner's Agent* Signed and sworn to before me this day of ,20/Le. #u - a IT RY PUBLIC in and for the State of Washington Residing at (/7 Name as commissioned: My commission expires: , County Del'?(/K 18.27.090 Exemptions. The registration provisions of this chapter do not apply to: 1. An authorized representative of the United States government, the state of Washington, or any incorporated city, town, county, township, irrigation district, reclamation district, or other municipal or political corporation or subdivision of this state; 2. Officers of a court when they are acting within the scope of their office; 3. Public utilities operating under the regulations of the utilities and transportation commission in construction, maintenance, or development work incidental to their own business; 4. Any construction, repair, or operation incidental to the discovering or producing of petroleum or gas, or the drilling, testing, abandoning, or other operation of any petroleum or gas well or any surface or underground mine or mineral deposit when performed by an owner or lessee; 5. The sale of any finished products, materials, or articles of merchandise that are not fabricated into and do not become a part of a structure under the common law of fixtures; 6. Any construction, alteration, improvement, or repair of personal property performed by the registered or legal owner, or by a mobile/manufactured home retail dealer or manufacturer licensed under chapter 46.70 RCW who shall warranty service and repairs under chapter 46.70 RCW; 7. Any construction, alteration, improvement, or repair carried on within the limits and boundaries of any site or reservation under the legal jurisdiction of the federal government; 8. Any person who only furnished materials, supplies, or equipment without fabricating them into, or consuming them in the performance of, the work of the contractor; 9. Any work or operation on one undertaking or project by one or more contracts, the aggregate contract price of which for labor and materials and all other items is Less than five hundred dollars, such work or operations being considered as of a casual, minor, or inconsequential nature. The exemption prescribed in this subsection does not apply in any instance wherein the work or construction is only a part of a larger or major operation, whether undertaken by the same or a different contractor, or in which a division of the operation is made into contracts of amounts less than five hundred dollars for the purpose of evasion of this chapter or otherwise. The exemption prescribed in this subsection does not apply to a person who advertises or puts out any sign or card or other device which might indicate to the public that he or she is a contractor, or that he or she is qualified to engage in the business of contractor; 10. Any construction or operation incidental to the construction and repair of irrigation and drainage ditches of regularly constituted irrigation districts or reclamation districts; or to farming, dairying, agriculture, viticulture, horticulture, or stock or poultry raising; or to clearing or other work upon land in rural districts for fire prevention purposes; except when any of the above work is performed by a registered contractor; 11. An owner* who contracts for a project with a registered contractor, except that this exemption shall not deprive the owner of the protections of this chapter against registered and unregistered contractors. The exemption prescribed in this subsection does not apply to a person who performs the activities of a contractor for the purpose of leasing or selling improved property he or she has owned for less than twelve months; 12.* Any person working on his or her own property, whether occupied by him or her or not, and any person working on his or her personal residence, whether owned by him or her or not but this exemption shall not apply to any person who performs the activities of a contractor on his or her own property for the purpose of selling, demolishing, or leasing the property; 13. An owner* who performs maintenance, repair, and alteration work in or upon his or her own properties, or who uses his or her own employees to do such work; 14. A licensed architect or civil or professional engineer acting solely in his or her professional capacity, an electrician certified under the laws of the state of Washington, or a plumber certified under the laws of the state of Washington or licensed by a political subdivision of the state of Washington while operating within the boundaries of such political subdivision. The exemption provided in this subsection is applicable only when the person certified is operating within the scope of his or her certification; 15. Any person who engages in the activities herein regulated as an employee of a registered contractor with wages as his or her sole compensation or as an employee with wages as his or her sole compensation; 16. Contractors on highway projects who have been prequalified as required by RCW 47.28.070, with the department of transportation to perform highway construction, reconstruction, or maintenance work; 17. A mobile/manufactured home dealer or manufacturer who subcontracts the installation, set-up, or repair work to actively registered contractors. This exemption only applies to the installation, set-up, or repair of the mobile/manufactured homes that were manufactured or sold by the mobile/manufactured home dealer or manufacturer; 18. An entity who holds a valid electrical contractor's license under chapter 19.28 RCW that employs a certified journeyman electrician, a certified residential specialty electrician, or an electrical trainee meeting the requirements of chapter 19.28 RCW to perform plumbing work that is incidentally, directly, and imm41i ely appropriate to the like=in-kind replacement of a household appliance or other small household utilization equipment that requires limited electric power and limited waste and/or water connections. An electrical trainee must be supervised by a certified electrician while performing plumbing work. ' Per Washington State Department of Labor and Industries lessee has been interpreted to be equivalent to owner for purposes of exemptions.