Loading...
HomeMy WebLinkAboutPermit D16-0229 - COSCO FIRE PROTECTION - TENANT IMPROVEMENTCOSCO FIRE PROTECTION 4308 S 131 PL D16-0229 Parcel No: Address: City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-438-9350 Web site: http://www.TukwilaWA.gov DEVELOPMENT PERMIT 7349200135 Permit Number: 4308 S 131ST PL Project Name: COSCO FIRE PROTECTION Issue Date: Permit Expires On: D16-0229 9/6/2016 3/5/2017 Owner: Name: Address: Contact Person: Name: Address: Contractor: Name: Address: License No: Lender: Name: Address: NORMED SHAW PTN PO BOX 3644 , SEATTLE, WA, 98124 PAUL GRUNDHOFFER 1411 4TH AVE, SUITE 810 , SEATTLE, WA, 98101 PATTISON GENERAL CONTRACTOR 15235 NE 90TH ST BLDG U, REDMOND, WA, 98052 PATTIGC917C7 OWNER FUNDED Phone: (206) 262-9622 Phone: (425) 978-8222 Expiration Date: 2/27/2017 DESCRIPTION OF WORK: INTERIOR TENANT IMPROVEMENT AT GROUND FLOOR INCLUDING NEW PARTITIONS, DOORS, LIGHTING AND FINISHES. NO CHANGE IN USE IN PROJECT. Project Valuation: $65,000.00 Type of Fire Protection: Sprinklers: YES Fire Alarm: Type of Construction: VB Electrical Service Provided by: TUKWILA Fees Collected: $1,946.32 Occupancy per IBC: B Water District: 125,TUKWILA Sewer District: TUKWILA Current Codes adopted by the City of Tukwila: International Building Code Edition: International Residential Code Edition: International Mechanical Code Edition: Uniform Plumbing Code Edition: International Fuel Gas Code: 2015 2015 2015 2015 2015 National Electrical Code: WA Cities Electrical Code: WAC 296-46B: WA State Energy Code: 2014 2014 2014 2015 Public Works Activities: Channelization/Striping: Curb Cut/Access/Sidewalk: Fire Loop Hydrant: Flood Control Zone: Hauling/Oversize Load: Land Altering: Landscape Irrigation: Sanitary Side Sewer: Sewer Main Extension: Storm Drainage: Street Use: Water Main Extension: Water Meter: Volumes: Cut: 0 Fill: 0 Number: 0 No Permit Center Authorized Signature: (4 - Date: I hearby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this development permit and agree to the conditions attached to this permit. Signature: ! Date: • Co, • l& Print Name: Pt-OP/0 eit4f2e This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: ***BUILDING PERMIT CONDITIONS*** 2: Work shall be installed in accordance with the approved construction documents, and any changes made during construction that are not in accordance with the approved construction documents shall be resubmitted for approval. 3: All permits, inspection record card and approved construction documents shall be kept at the site of work and shall be open to inspection by the Building Inspector until final inspection approval is granted. 4: New suspended ceiling grid and light fixture installations shall meet the seismic design requirements for nonstructural components. ASCE 7, Chapter 13. 5: Partition walls shall not be tied to a suspended ceiling grid. All partitions greater than 6 feet in height shall be laterially braced to the building structure. Such bracing shall be independent of any ceiling splay bracing. 6: All construction shall be done in conformance with the Washington State Building Code and the Washington State Energy Code. 7: All rack storage requires a separate permit issued through the City of Tukwila Permit Center. Rack storage over 8 -feet in height shall be anchored or braced to prevent overturning or displacement during seismic events. The design and calculations for the anchorage or bracing shall be prepared by a registered professional engineer licensed in the State of Washington. Periodic special inspection is required during anchorage of storage racks 8 feet or greater in height. 8: There shall be no occupancy of a building until final inspection has been completed and approved by Tukwila building inspector. No exception. 9: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of this requirement. 10: Every occupied space other than enclosed parking garages and buildings used for repair of automobiles shall be ventilated in accordance with the applicable provisions of the International Mechanical Code. 11: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206-431-3670). 12: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center. 13: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 14: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431-3670). 18: The total number of fire extinguishers required for a light hazard occupancy with Class A fire hazards is calculated at one extinguisher for each 3,000 sq. ft. of area. The extinguisher(s) should be of the "all purpose" (2A, 10 B:C) dry chemical type. The travel distance to any extinguisher must be 75' or less. (IFC 906.3) (NFPA 10, 5.4) 19: The total number of fire extinguishers required for an ordinary hazard occupancy with Class A fire hazards is calculated at one extinguisher for each 1,500 sq. ft. of area. The extinguisher(s) should be of the "All Purpose" (3A, 40B:C) dry chemical type. Travel distance to any fire extinguisher must be 75' or less. (IFC 906.3) (NFPA 10, 5.4) 15: Portable fire extinguishers, not housed in cabinets, shall be installed on the hangers or brackets supplied. Hangers or brackets shall be securely anchored to the mounting surface in accordance with the manufacturer's installation instructions. Portable fire extinguishers having a gross weight not exceeding 40 pounds (18 kg) shall be installed so that its top is not more than 5 feet (1524 mm) above the floor. Hand- held portable fire extinguishers having a gross weight exceeding 40 pounds (18 kg) shall be installed so that its top is not more than 3.5 feet (1067 mm) above the floor. The clearance between the floor and the bottom of the installed hand-held extinguishers shall not be less than 4 inches (102 mm). (IFC 906.7 and IFC 906.9) 16: Extinguishers shall be located in conspicuous locations where they will be readily accessible and immediately available for use. These locations shall be along normal paths of travel, unless the fire code official determines that the hazard posed indicates the need for placement away from normal paths of travel. (IFC 906.5) 17: Fire extinguishers require monthly and yearly inspections. They must have a tag or label securely attached that indicates the month and year that the inspection was performed and shall identify the company or person performing the service. Every six years stored pressure extinguishers shall be emptied and subjected to the applicable recharge procedures. If the required monthly and yearly inspections of the fire extinguisher(s) are not accomplished or the inspection tag is not completed, a reputable fire extinguisher service company will be required to conduct these required surveys. (NFPA 10, 7.2, 7.3) 20: Maintain fire extinguisher coverage throughout. 21: Egress doors shall be readily openable from the egress side without the use of a key or special knowledge or effort. (IFC 1008.1.8.3 subsection 2.2) 22: Dead bolts are not allowed on auxiliary exit doors unless the dead bolt is automatically retracted when the door handle is engaged from inside the tenant space. (IFC Chapter 10) 23: Exit hardware and marking shall meet the requirements of the International Fire Code. (IFC Chapter 10) 24: Door handles, pulls, latches, locks and other operating devices on doors required to be accessible by Chapter 11 of the International Building Code shall not require tight grasping, tight pinching or twisting of the wrist to operate. (IFC 1008.1.9.1) 25: Exits and exit access doors shall be marked by an approved exit sign readily visible from any direction of egress travel. Access to exits shall be marked by readily visible exit signs in cases where the exit or the path of egress travel is not immediately visible to the occupants. Exit sign placement shall be such that no point in an exit access corridor is more than 100 feet (30,480 mm) or the listed viewing distance for the sign, whichever is less, from the nearest visible exit sign. (IFC 1011.1) 26: Every exit sign and directional exit sign shall have plainly legible letters not less than 6 inches (152 mm) high with the principal strokes of the letters not less than 0.75 inch (19.1 mm) wide. The word "EXIT" shall have letters having a width not less than 2 inches (51 mm) wide except the letter "I", and the minimum spacing between letters shall not be less than 0.375 inch (9.5 mm). Signs larger than the minimum established in section 1011.5.1 of the International Fire Code shall have letter widths, strokes and spacing in proportion to their height. The word "EXIT" shall be in high contrast with the background and shall be clearly discernible when the exit sign illumination means is or is not energized. If an arrow is provided as part of the exit sign, the construction shall be such that the arrow direction cannot be readily changed. (IFC 1011.6) 27: Aisles and aisle access ways serving as a portion of the exit access in the means of egress system shall comply with the requirements of this section. Aisles or aisle access ways shall be provided from all occupied portions of the exit access which contain seats, tables, furnishings, displays and similar fixtures or equipment. The required width of aisles shall be unobstructed. (IFC 1017.1) 28: Exit signs shall be illuminated at all times. To ensure continued illumination for a duration of not less than 90 minutes in case of primary power loss, the sign illumination means shall be connected to an emergency power system provided from storage batteries, unit equipment or on-site generator. (IFC 1011.6.3) 29: Emergency lighting facilities shall be arranged to provide initial illumination that is at least an average of 1 foot-candle (11 lux) and a minimum at any point of 0.1 foot-candle (1 lux) measured along the path of egress at floor level. Illumination levels shall be permitted to decline to 0.6 foot-candle (6 lux) average and a minimum at any point of 0.06 foot-candle (0.6 lux) at the end of the emergency lighting time duration. A maximum-to-minimum illumination uniformity ratio of 40 to 1 shall not be exceeded. (IFC 1006.3.1) 33: Fire protection systems shall be maintained in accordance with the original installation standards for that system. Required systems shall be extended, altered or augmented as necessary to maintain and continue protection whenever the building is altered, remodeled or added to. Alterations to fire protection systems shall be done in accordance with applicable standards. (IFC 901.4) 31: Sprinklers shall be installed under fixed obstructions over 4 feet (1.2 m) wide. (NFPA 13-8.6.5.3.3) 30: All new sprinkler systems and all modifications to existing sprinkler systems shall have fire department review and approval of drawings prior to installation or modification. New sprinkler systems and all modifications to sprinkler systems involving more than 50 heads shall have the written approval of Factory Mutual or any fire protection engineer licensed by the State of Washington and approved by the Fire Marshal prior to submittal to the Tukwila Fire Prevention Bureau. No sprinkler work shall commence without approved drawings. (City Ordinance No. 2436). 35: An approved manual fire alarm system including audible/visual devices and manual pull stations is required for this project. The fire alarm system shall meet the requirements of Americans With Disabilities' Act (I.B.C.), N.F.P.A. 72 and the City of Tukwila Ordinance #2437. 36: Maintain fire alarm system audible/visual notification. Addition/relocation of walls or partitions may require relocation and/or addition of audible/visual notification devices. (City Ordinance #2437) 34: All new fire alarm systems or modifications to existing systems shall have the written approval of The Tukwila Fire Prevention Bureau. No work shall commence until a fire department permit has been obtained. (City Ordinance #2437) (IFC 901.2) 37: An electrical permit from the City of Tukwila Building Department Permit Center (206-431-3670) is required for this project. 38: All electrical work and equipment shall conform strictly to the standards of the National Electrical Code. (NFPA 70) 39: The maximum flame spread class of finish materials used on interior walls and ceilings shall not exceed that set forth in Table No. 803.9 of the International Building Code. 32: Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (City Ordinances #2436 and #2437) 40: Any overlooked hazardous condition and/or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. 41: These plans were reviewed by Inspector 511. If you have any questions, please call Tukwila Fire Prevention Bureau at (206)575-4407. PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 1700 BUILDING FINAL** 0611 EMERGENCY LIGHTING 1400 FIRE FINAL 0409 FRAMING 0606 GLAZING 0406 SUSPENDED CEILING CITY OF TUM Community Development Department Public Works Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.TukwilaWA.gov Building Permit No. V 1 h- 0 Z2-61 Project No. Date Application Accepted: Date Application Expires: (For office use only) CONSTRUCTION PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **Please Print** SITE LOCATION Site Address: 4308 S. 131 Street Place Tenant Name: Cosco Fire Protection King Co Assessor's Tax No.: 7349200135 Suite Number: Floor: 1 New Tenant: ❑ Yes I ..No PROPERTY OWNER Name: Paul Grundhoffer Name: NorMed Shaw Partnership City: Seattle State: WA Zip: 98101 Address: PO Box 3644 Email: paulg@weaverarch.com City: Seattle State: WA Zip: 98124 CONTACT PERSON — person receiving all project communication Name: Paul Grundhoffer Address: 1411 4th Ave. Suite 810 City: Seattle State: WA Zip: 98101 Phone: (206) 262-9622 Fax: (206) 262-9507 Email: paulg@weaverarch.com GENERAL CONTRACTOR INFORMATION Company Name: TBD Company Name: Weaver Architects Company Name: Architect Name: Hank Weaver Address: Address: 1411 4th Ave. Suite 810 City: Seattle State: WA City: State: 262-9507 Zip: Phone: Fax: Phone: Fax: Contr Reg No.: Email: Exp Date: Tukwila Business License No.: H:\Applications\Forms-Applications On Linc\201 I Applications\Permit Application Revised - 8-9-I I.docx Revised: August 2011 bh ARCHITECT OF RECORD Name: None, Owners Cash Company Name: Weaver Architects Company Name: Architect Name: Hank Weaver Address: 1411 4th Ave. Suite 810 City: Seattle State: WA Zip: 98101 Phone: (206) 262-9622 Fax: (206) 262-9507 Email: paulg@weaverarch.com State: ENGINEER OF RECORD Name: None, Owners Cash Address: Company Name: Engineer Name: Address: City: State: Zip: Phone: Fax: Email: LENDER/BOND ISSUED (required for projects $5,000 or greater per RCW 19.27.095) Name: None, Owners Cash Address: City: State: Zip: Page 1 of 4 BUILDING PERMIT INFORMATI( J 206-431-3670 Valuation of Project (contractor's bid price): $ 65,000 Existing Building Valuation: $ 2,488,000 Describe the scope of work (please provide detailed information): Will there be new rack storage? ❑ Yes 2.. No If yes, a separate permit and plan submittal will be required. Provide All Building Areas in Square Footage Below PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: 87 Compact: 18 Handicap: 5 Will there be a change in use? 0 Yes m No If "yes", explain: FIRE PROTECTION/HAZARDOUS MATERIALS: Sprinklers 0 Automatic Fire Alarm ❑ None 0 Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? 0 Yes No If 'yes', attach list of materials and storage locations on a separate 8-1/2" x 11" paper including quantities and Material Safety Data Sheets. SEPTIC SYSTEM 0 On-site Septic System — For on-site septic system, provide 2 copies of a current septic design approved by King County Health Department. H:\Applications\Forms-Applications On Line \2011 Applications\Permit Application Revised - 8-9-11.docx Revised: August 2011 bh Page 2 of 4 Existing Interior Remodel Addition to Existing Structure New Type of Construction per IBC Type of Occupancy per IBC 15` Floor 28,520 4,400 0 0 V -B B, S-1 2nd Floor 3rd Floor Floors thru Basement Accessory Structure* Attached Garage Detached Garage Attached Carport Detached Carport Covered Deck Uncovered Deck PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: 87 Compact: 18 Handicap: 5 Will there be a change in use? 0 Yes m No If "yes", explain: FIRE PROTECTION/HAZARDOUS MATERIALS: Sprinklers 0 Automatic Fire Alarm ❑ None 0 Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? 0 Yes No If 'yes', attach list of materials and storage locations on a separate 8-1/2" x 11" paper including quantities and Material Safety Data Sheets. SEPTIC SYSTEM 0 On-site Septic System — For on-site septic system, provide 2 copies of a current septic design approved by King County Health Department. H:\Applications\Forms-Applications On Line \2011 Applications\Permit Application Revised - 8-9-11.docx Revised: August 2011 bh Page 2 of 4 PUBLIC WORKS PERMIT INFO., CATION — 206-433-0179 Scope of Work (please provide detailed information): INTERIOR TENANT IMPROVEMENT AT GROUND FLOOR INCLUDING NEW PARTITIONS, DOORS, LIGHTING, AND FINISHES. NO CHANGE OF USE IN PROJECT. Call before you Dig: 811 Please refer to Public Works Bulletin #1 for fees and estimate sheet. Water District ❑ ...Tukwila ❑ ...Water District #125 ..▪ .Water Availability Provided Sewer District 0 ...Tukwila 0 ...Sewer Use Certificate 0 .. Highline ❑...Valley View ❑ .. Renton m ... Sewer Availability Provided ❑ .. Renton 0 .. Seattle Septic System: O On-site Septic System — For on-site septic system, provide 2 copies of a current septic design approved by King County Health Department. Submitted with Application (mark boxes which apply): ❑ ...Civil Plans (Maximum Paper Size — 22" x 34") ❑ ...Technical Information Report (Storni Drainage) ❑ ...Bond 0 .. Insurance 0 .. Easement(s) Proposed Activities (mark boxes that applv): 0 ...Right-of-way Use - Nonprofit for less than 72 hours ❑ ...Right-of-way Use - No Disturbance ❑ ...Construction/Excavation/Fill - Right-of-way 0 Non Right-of-way ❑ ...Total Cut 0 ...Total Fill cubic yards cubic yards ❑ ...Sanitary Side Sewer ❑ ...Cap or Remove Utilities 0 ...Frontage Improvements ❑ ...Traffic Control ❑ ...Backflow Prevention - Fire Protection Irrigation Domestic Water ❑ .. Geotechnical Report ❑ .. Maintenance Agreement(s) ❑...Traffic Impact Analysis ❑ ...Hold Harmless — (SAO) ❑ ...Hold Harmless — (ROW) ❑ .. Right-of-way Use - Profit for less than 72 hours O .. Right-of-way Use — Potential Disturbance ❑ .. Work in Flood Zone ❑ .. Storm Drainage ❑ .. Abandon Septic Tank ❑ .. Curb Cut ❑ .. Pavement Cut ❑ .. Looped Fire Line 11 O ...Permanent Water Meter Size... ❑ ...Temporary Water Meter Size .. ❑ ...Water Only Meter Size ❑ ...Sewer Main Extension Public ❑ ❑ ...Water Main Extension Public ❑ 11 WO# WO# WO# Private Private ❑ .. Grease Interceptor ❑ .. Channelization 0 .. Trench Excavation ❑ .. Utility Undergrounding ❑...Deduct Water Meter Size FINANCE INFORMATION Fire Line Size at Property Line ❑ ...Water 0 ...Sewer Monthly Service Billing to: Number of Public Fire Hydrant(s) 0 ...Sewage Treatment Name: Day Telephone: Mailing Address: City State Zip Water Meter Refund/Billing: Name: Mailing Address: Day Telephone: City State Zip H:Wpplications\Forms-Applications On Line \2011 Applications\Permit Application Revised - 8-9-11.docx Revised: August 2011 bh Page 3 of 4 PERMIT APPLICATION NOTES —' Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cauge demonstrated. Section 105.3.2 International Building Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNEROR HORI 1 AGE :J Signature: 4 ' - �/ Date: 08/11/2016 Print Name: Paul Grundhoffer Mailing Address: 1411 4th Ave., Suite 810, H:Wpplications\Forms-Applications On Line \2011 Applications\Permit Application Revised - 8-9-11.docx Revised: August 2011 bh Day Telephone: (206) 262-9622 Seattle WA 98101 City State Zip Page 4 of 4 Cash Register Receipt City of Tukwila DESCRIPTIONS PermitTRAK I ACCOUNT I QUANTITY I PAID $1,203.86 D16-0229 Address: 4308 S 131ST PL Apn: 7349200135 $1,203.86 DEVELOPMENT $1,146.75 PERMIT FEE R000.322.100.00.00 0.00 $1,142.25 WASHINGTON STATE SURCHARGE B640.237.114 0.00 $4.50 TECHNOLOGY FEE $57.n TECHNOLOGY FEE TOTAL FEES PAID BY RECEIPT: R9336 R000.322.900.04.00 0.00 $57.11 $1,203.86 Date Paid: Tuesday, September 06, 2016 Paid By: COSCO FIRE PROTECTION Pay Method: CHECK 2789 Printed: Tuesday, September 06, 2016 1:16 PM 1 of 1 Eil`' SYSTEMS Cash Register Receipt City of Tukwila DESCRIPTIONS ACCOUNT QUANTITY PAID PermitTRAK $742.46 D16-0229 Address: 4308 S 131ST PL Apn: 7349200135 $742.46 DEVELOPMENT $742.46 PLAN CHECK FEE TOTAL FEES PAID BY RECEIPT: R9176 R000.345.830.00.00 0.00 $742.46 $742.46 Date Paid: Thursday, August 11, 2016 Paid By: WEAVER ARCHITECTS Pay Method: CHECK 2508 Printed: Thursday, August 11, 2016 3:51 PM 1 of 1 CRWSYSTEMS VOAINSPECTION RECORD Retain a copy with permit IN 0N NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-367 Permit Inspection Request Line (206) 438-9350 b%l. - Uzq Pro'ect: r� Ira- ��26?L`crbAD Type of Inspection: �, Bu i t i J F/ 2 L A dress: 4306 s 13151— PL Date Called: Special Instructions: Date Wanted' z/z4/G a.m. Requester. Phone No: Approved per applicable codes. D Corrections required prior to approval. COMMENTS: Inspector: A REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. U..- O ZZfi CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Pro?ect: �, ro SCC) itiVe Prone mid Type of Inspection: 6-1/+/-/ J6- Address: eaoe c /3)57- Pt Date Called: Special Instructions: Date Wanted 1224+/1 6 a.m. Requester• Phone No: %Approved per applicable codes. Corrections required prior to approval. COMMENTS: Inspector: Date) Z /6 REINSPECTION FEE REQUIRED. Prior to next inspec ZQion, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit INSP ION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION (206) 431-3670 b'6 2,zq 6300 Southcenter Blvd., #100, Tukwila. WA 98188 Permit Inspection Request Line (206) 438-9350 Pr ct:aorwrwvType (� of Inspection: SxateA)bn Coo A16- Address: 1130g 13Ic Pa Date Called: Special Instructions: CALL Date Wanted: �/ j /1 ,1 / a.m. p.m. Requester wirL Phone No: 2uz — siS-L{ - 96 b i Approved per applicable codes. Corrections required prior to approval. COMMENTS: Inspector: Date/,9/// / REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. t)lt• INSPECTION NO. INSPECTION RECORD Retain a copy with permit CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 1)i(- ()Mg PERMIT NO. Project: CSa ciiee P r rx'/ Type of pection: rice► /Ai& Address: 4 3o8 S 13i sr- SPL Date Called: Special Instructions: Date WantediV a.m. Request Phone No: NApproved per applicable codes. Corrections required prior to approval. COMMENTS: ectorl�� Date: 9/2o..//6 2o�i6 REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. INSPECTION NUMBER INSPECTION RECORD Retain a copy with permit t;ter C.)GLj Its -F-- z o PERMIT NUMBERS CITY OF TUKWILA FIRE DEPARTMENT 206-575-4407 Project:Type o A -;.-E- of Inspection: 677vt e-',---- L , ,_,,__L N Hood & Duct: Address:,._4-. Suite #: � s . 1 33 --FL Contact Person: ' \ Special Instructions: — 6-,r1 tom" c -e r Phone No.: - a,47.4' r Approved per applicable codes. Corrections required prior to approval. COMMENTS: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: — 6-,r1 tom" c -e r / fG 41 --Lo ✓-t - a,47.4' r f- -/ 1 7 / z 1_ r (• u (-T co'I . G(1 /bra ).L `-k- • s ►QC - -a.</6_`'" f t -1/4A ------4--*--s 0 Needs Shift Inspection: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: Inspector:; C 3 Date: /2/r0( Hrs.: ' U / / $100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. Billing Address Attn: Company Name: Address: City: State: Zip: Word/Inspection Record Form.Doc 3/14/14 T.F.D. Form F.P. 113 INSPEc ION RECORD Retard a copy with permit INSPECTION NUMBER ?�I � - o z 2 -yo PERMIT NUMBERS CITY OE TUKWILA FIRE REPARTMENT r 206-575-4407 Project: Gam" f' ' Fire Alarm: Hood & Duct: Type of Inspection: .6.-)1,701_e__,,,, Address:Contact Suite #: ,,SSC/ T /'` ,/ /" Person: Special Instructions: Phone No,: Approved per applicable codes. orrections re d prior to approval. COMMENTS: Anzyz- Add !,►'''!' /1/I�'2 2. /� /� A TS 7 Add Aloft'� 1-..oksa Needs Shift Inspection: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: Inspector: ,� 5-3 1 Date: /2 Hrs.: $100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. CaII to schedule a reinspection. Billing Address Attn: Company Name: Address: City: State: Zip: Word/Inspection Record Form.Doc T.F.D. Form F.P. 113 INSPECTION NUMBER INSPECTION RECORD Retain a copy with permit b1to- Q2 Z /C --F- `0 PERMIT NUMBERS CITY OF TUKWILA FIRE DEPARTMENT 206-575-4407 Project: Type of Inspection: Address: Suite #: V5)0 t S/3/ r_ Contact Person: Special Intructions: Phone No.: %Approved per applicable codes. Corrections required prior to approval. COMMENTS: t Needs Shift Inspection: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: Inspector: —XL- f j 3 Date: 12//2/ /G Hrs.: /,c� $100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. Billing Address Attn: Company Name: Address: City: State:. Zip: Word/Inspection Record Form.Doc;, 3/14/14 T.F.D. Form F.P. 113 INSPECTION NUMBER INSPECTION RECORD Retain a copy with permit PERMIT NUMBERS CITY OF TUKWILA FIRE DEPARTMENT 206-575-4407 Project:, Project:Type sPry of Inspection: Y/i 6 - Address: i;/Suite #: Zfr3A 5 . � c) -f- PL Contact Person: Special Instructions: Phone No.: Approved per applicable codes. Corrections required prior to approval. COMMENTS: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: F/A- EirML— - Oe --- 5,--p\)8 $//E1 Piz F FE sl-- �Oi2t se -NO F,9 -P t -1/57-0L, — 00 l 4 niA7)La & faopir (zE-zt--)0. Fa /6_(--r( ,9 Needs Shift Inspection: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: Inspector: f1 ' 4-/ 5'3 Date: / Z. III 1 (;, Hrs.: / $100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. Billing Address Attn: Company Name: Address: City: State: Zip: Word/Inspection Record Form.Doc 3/14/14 T.F.D. Form F.P. 113 I INSPECTION NUMBER INSPECTION RECORD Retain a copy with permit Dig- oaaq /6- 5 --- a o : PERMIT NUMBERS CITY OF TUKWILA FIRE DEPARTMENT 206-575-4407 Project:, C,Sc 0 Sprinklers: f ,e Hood & Duct: Type of Inspection: fro (Th (,—.- Address: y 30 e Suite #: S 1 3 1 ?L Contact Person: Special Instructions: Phone No.: Approved per applicable codes. Corrections required prior to approval. COMMENTS: SP Coc...kr ��-- Needs Shift Inspection: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: Inspector: ✓o Date: WOIgJ,6 Hrs.: $100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. Billing Address Attn: Company Name: Address: City: State: Zip: Word/Inspection Record Form.Doc 3/14/14 T.F.D. Form F.P. 113 Lighting Summary LGT-SUM 2015 Washington State Energy Code Compliance Forms for Commercial Buildings including R2, R3, R4 over 3 stories and all R1 Revised July 2016 Project Info Compliance forms do not require a password to use. Instructional and calculating cells are write protected. Project Title: Cosco Fire Protection Date 8/4/2016 Applicant Information. Provide contact information for individual who can respond to inquiries about compliance form information provided. For Buil • n g D FOR CODE COMPLIANC APP ROVED AUG 2 6 2016 A II e. Cl `LA�� fPr �d with I •l t ii GasiGf r VISIOh Company Name: Weaver Architects Company Address: 1411 4th Ave Suite 810, Seattle WA Applicant Name: Weaver Architects, Paul Grundhoffer Applicant Phone: 206.262.9622 Applicant Email: paulg@weaverarch.com Project Description ❑ New Building 1 Addition El Alteration Include PROJ-SUM form (included in envelope forms workbook) Building Additions Refer to Section C502.2.6 for additional requirements. ri IL , .� Compliance Method Interior lighting Exterior lighting Lighting systems in addition area comply with all applicable provisions as a stand alone new construction project ❑ Lighting systems in addition are combined with existing building lighting systems to demonstrate compliance ❑ . Addition is combined with existing: For interior lightingprojects, include new + interior li htin fixture in Li htin p 1existing lighting wattageProposedLighting Wattage table in LTG -INT -BLD or LTG -INT -SPACE form. For exterior lighting projects, include new + existing exterior lighting fixture wattage in Proposed Tradable and Proposed Non -Tradable Lighting Wattage tables in LTG -EXT form. Interior and Exterior Lighting Alterations Select all Lighting Power and Lighting Control elements that apply to the scope of the retrofit project. If project includes a combination of spaces where less than 50% of the existing fixtures are replaced in some spaces, and 50% or more of the fixtures are replaced in others, then provide separate lighting power compliance forms for the two retrofit conditions. Spaces undergoing the same type of retrofit may be combined into one lighting power compliance form. Refer to Section C503.6 for additional requirements. All alteration lighting controls shall be commissioned per C408.3. El No changes are being made to the interior or exterior lighting systems and existing space uses and configuration are not changed. Lighting Power Interior lighting Parking garage Exterior lighting 50% or more of existing are replaced 0 ❑ 0 Less than 50% of existing are replaced ❑ ❑ Lamp and/or ballast replacement only — existing total wattage not increased 0 ❑ 0 50% or more replaced - Total lighting power of new + existing -to -remain fixtures shall comply with total LPA per Sections C405.4.2 and C405.5.2. Include new + existing -to -remain fixtures in Proposed Lighting Wattage table in LTG -INT -BLD, LTG -INT -SPACE or LTG -EXT form. Less than 50% replaced - Total lighting power of new + existing -to -remain fixtures shall not exceed the total lighting power prior to alteration. Include new + existing -to -remain fixtures in the Proposed Lighting Wattage table in LTG -INT -BLD, LTG -INT -SPACE or LTG -EXT form. 50% threshold applies to number of luminaires for interior spaces and parking garages, and total installed wattage for exterior luminaires. Lighting Controls Interior lighting Parking garage Exterior lighting New wiring installed to serve added fixtures and/or fixtures relocated to new circuit(s) ❑' ❑ New or moved lighting panel ❑ 0 0 Interior space is reconfigured - luminaires unchanged or relocated only ❑ New wiring or circuit - For interior lighting, provide required manual controls per C405.2.3, occupancy sensor controls per C405.2.1, daylight responsive controls per C405.2.4 and application specific lighting controls per C405.2.5. For exterior lighting, provide required controls per C405.2.7. New or moved panel - Provide all applicable lighting controls as noted for New Wiring and automatic time switch controls per C405.2.2. Reconfigured interior space - Provide all required lighting controls that apply to a new interior space. Application specific lighting control provisions per C405.2.5 do not apply to reconfigured spaces. Change of Space Use CITY OF OF KWILA ❑ Existing interior lighting systems in areas under -going a change in space use are upgraded to comply with LPAs for the new space types per Tables C405.4.2(1) or C405.4.2(2). Identify interior spaces requiring LPD upgrade to the current Code in Proposed Lighting Wattage table in LTG -INT -BLD or LTG -INT -SPACE form. AUG 112016 PERMIT CENTER Dl(,O2.V* Lighting Summary, cont. LGT-SUM 2015 Washington State Energy Code Compliance Forms for Commercial Buildings including R2, R3, R4 ov Project Title: Cosco Fire Protection Date 8/4/2016 Interior Lighting System Description All existing storage /warehouse area lighting to remain. Majority of office area lighting to remain other that locaitons were wall are being removed or revised. See RCP for extent of work. Interior Lighting Power Allowance•Method . Q Building Area Method ❑ Space -by -space Method Select method used in project. Interior Lighting Controls Q All C405.2.1 - C405.2.8 Controls ❑ C405.2 Exception 5 Luminaire Level Lighting Control (LLLC) ❑ Additional Efficiency Package Option C406.4 Enhanced digital lighting controls To comply with C406.4, no less than 90% of the total installed interior lighting power shall comply with the required controls per C406.4. _lei_ Dwelling Unit Interior Lighting Permanently installed interior lighting fixtures in dwelling units comply with: EQ s 0 C405.2 thru C405.5 Commercial Lighting Controls and LPA r,: ,.i :., -� o C406.3 High Efficacy Lighting 0 Exterior Lighting System Description No work A .01N:4 I f +l > Interior Lighting - Space -By -Space Method LTG -INT -SPACE 2015 Washington State Energy Code Compliance Forms for Commercial Buildings including R2, R3, R4 over 3 stories and all R1 Revised July 2016 Project Title: Cosco Fire Protection Date 8/4/2016 Calculation Area NOTE s 0 0 Addition - 0 Addition stand alone + existing Spaces where < 50% of 0 Spaces where 2 50% of o luminaires are replaced luminaires are replaced For Building Department Use LPA Calculation Type ® Standard 0 Additional Efficiency Package Option 0 c406.3 Reduced Interior Lighting Power To comply with C406.3, the Proposed LPD shall be 25% lower than the Target LPA. Refer to C406.3 for additional requirements. Maximum Allowed Lighting Wattage ""E1 2 Location (plan #, room #) Space Type Ceiling Height NOTE 2 Gross Interior Area in ft2 Allowed Watts per ft2 Watts Allowed (watts/ft2 x area) 88 106 New LED can light 1 10 10 100 New LED can light 2 10 20 Enter Lobby Art/Exhibit Display Allowance from LTG -INT -DISPLAY NOTE 8 Total Area Retail Display Total Existing LTG -INT -DISPLAY (prior to Alteration) Allowed Watts Allowance from Lighting Watts 256 256 Proposed Lighting Wattage ""'°' Location (plan #, room #) Fixture Description NOTE 4, 5, 6 Number of Fixtures Watts/ Fixture NOTE 7 Watts Proposed 102 New LED 2x4 fixture 2 44 88 103 New LED 2x4 fixture 2 44 88 106 New LED can light 1 10 10 100 New LED can light 2 10 20 Proposed Retail Display Lighting from LTG -INT -DISPLAY Total Proposed Watts may not exceed Total Allowed Watts for Interior Lighting Total Proposed Watts 206 Interior Lighting Power Allowance COMPLIES Note 1 - List all unique space types per Table C405.4.2(2) that occur in the project scope. Select space type category per from drop down menu. Note 2 - Indicate ceiling height for atriums and spaces utilizing the ceiling height adjustment per Table C405.4.2(2), Footnotes d thru f. Note 3 - List all proposed lighting fixtures including exempt lighting equipment and existing -to -remain fixtures. Note 4 - For proposed Fixture Description, indicate fixture type, lamp type (e.g. T-8), number of lamps in the fixture, and ballast type (if included). For track lighting, list the length of the track (in feet) in addition to the fixture, lamp, and ballast information. Note 5 - For lighting equipment eligible for exemption per C405.4.1, note exception number and leave Watts/Fixture blank. Note 6 - Existing -to -remain fixtures shall be included in the Proposed Lighting Wattage table in the same manner as new fixtures. Identify as existing . in fixture description. Note 7 - For proposed Watts/Fixture enter the luminaire wattage for installed lamp and ballast using manufacturer or other approved source. For luminaires with screw-in lamps, enter the manufacturer's listed maximum input wattage of the fixture (not the lamp wattage). For low voltage lighting, enter the wattage of the transformer. For line voltage track/busway systems, enter the larger of the attached luminaire wattage or 50 watts/lineal foot, or enter the wattage limit of permanent current limiting device. Note 8 - Lobby Art/Exhibit Display Allowance is independent of the Maximum Allowed Lighting Wattage. Note 9 - Calculation Area Details: a. Lighting fixtures in a building addition may comply as a stand alone project, or they may be combined with the overall existing building lighting systems to demonstrate compliance. Refer to C502.1. b. For alterations and building additions, provide Space Types and gross interior areas in the Maximum Allowed Lighting Wattage table. if a building addition will comply as combined with the overall existing building lighting systems, include all applicable existing Space Types and gross interior areas. • c. if less than 50% of existing lighting fixtures will be replaced, provide total existing lighting wattage (prior to alteration) in the space provided Lighting, Motor, and Electrical Permit Checklist, Pg. 1 LTG -CHK Revised July 2016 2015 Washington State Energy Code Compliance Forms for Commercial Buildings including R2, R3, R4 over 3 stories and all R1 Project Title: Cosco Fire Protection Date 8/4/2016 The following information is necessary to check a permit application for compliance with the lighting, motor, and electrical requirements in the Washington State Energy Code, Commercial Provisions. Applicability (yes,no,na) Code Section Component Compliance information required in permit documents Location in Documents Building Department Notes LIGHTING CONTROLS C405.2 Lighting controls, general For all lighting fixtures, indicate lighting control method on plans for spaces and lighting zone(s) served, or exception taken C405.2 Luminaire level lighting controls (LLLC) Indicate on plans all fixtures provided with LLLC in lieu of C405.2 lighting controls; provide description of control capabilities and performance parameters C405.1 Lighting in dwelling units For permanently installed lighting fixtures in dwelling units, indicate lighting control method on plans for spaces and lighting zone(s) served, or demonstrate compliance with high efficacy exception C405.2.3 C405.2.1.1 C405.2.2.2 C405.2.4 C405.2.5 Manual controls Indicate on plans the method of manual lighting control (whether combined with occupancy sensor, automatic light reduction, daylight responsive or specific application controls), location of manual control device and area or specifice application it serves C405.2.2.1 C405.2.2.2 C405.2.3 Manual interior lighting controls Indicate on plans which method of manual 50% lighting load reduction is provided, or whether lighting load is reduced via occupancy sensors or daylight responsive controls C405.2.2 Method of automatic shut-off control Indicate on plans the method of automatic shut-off control during unoccupied periods (occupancy sensor or time switch) for all lighting zones; Indicate locations where automatic shutoff is provided by other methods (occupancy sensor or digital timer switch) or which time switch control exception applies C405.2.1 C405.2.1.1 Occupancy sensor controls Indicate on plans the spaces served by occupancy sensors; Indicate whether occupancy sensor controls are configured to be manual -on, automatic 50% -on, or serve a space eligible for automatic 100% -on per exception C405.2.1.2 Occupancy sensor controls - warehouses Indicate aisleways and open areas in warehouse spaces provided with occupancy sensor controls that reduce lighting power by 50% C405.2.6 Digital timer switch Indicate required digital timer switch control function when control is used C405.2.2.1 Automatic time switch controls Indicate locations of override switches on plans and the lighting zone(s) served, include area sq. ft. C405.2.4.2 C405.2.4.3 Daylight zones - Sidelight and toplight Indicate primary and secondary sidelight daylight zone areas on plans, include sq. ft.; Indicate toplight daylight zone areas on plans, include sq. ft.; For small vertical fenestration assemblies (rough opening less than 10 percent of primary daylight zone) where daylight responsive controls are not required, provide fenestration area to daylight zone calculation(s) C405.2.4 Daylight responsive controls Indicate on plans lighting zone(s) served by daylight responsive controls; Identify sidelight and toplight daylight zones that are not provided with daylight sensing controls and the exception(s) that apply; Indicate on plans the lighting load reduction method - continuous dimming, or stepped dimming that provides at least two even steps between 0%-100% of rated power; Indicate that daylight sensing controls are configured to completely shut off all controlled lights in the lighting zone C405.2.5 Additional controls Specific application lighting controls Identify spaces and lighting fixtures on plans that require specific application lighting controls per this section C405.2.5 - Items 1&2 Display and accent lighting Indicate on plans that display and accent lighting, and display case lighting are controlled independently from both general area lighting and other lighting applications within the same space; Indicate manual and automatic lighting control method Lighting, Motor, and Electrical Permit Checklist, Pg. 2 LTG -CHK 2015 Washington State Energy Code Compliance Forms for Commercial Buildings including R2, R3, R4 over 3 stories and all R1 Revised July 2016 Project Title: Cosco Fire Protection Date 8/4/2016 The following information is necessary to check a permit application for compliance with the lighting, motor, and electrical requirements in the Washington State Energy Code, Commercial Provisions. Applicability (yes,no,na) Code Section Component Compliance information required in permit documents Location in Documents Building Department Notes C405.2.5 - Item 3 Hotel/motel guest rooms Indicate method of automatic control - vacancy or captive key control of all installed luminaires and switched receptacles in guest room C405.2.5 Item 4 Supplemental task lighting Indicate method and location of automatic shut-off vacancy control for supplemental task lighting, including under -shelf or under -cabinet lighting C405.2.5 - Item 5 Lighting for non- visual applications Indicate on plans eligible non -visual lighting applications, include sq. ft. area of each lighting control zone; Indicate on plans that non -visual lighting are controlled independently from both general area lighting and other lighting applications within the same space; Indicate method of manual lighting control and applicable automatic lighting control C405.2.5 - Item 6 Lighting equipment for sale or demonstration Indicate on plans that lighting equipment for sale or demonstration are controlled independently from both general area lighting and other lighting applications within the same space; Indicate method of manual lighting control and applicable automatic lighting control C405.2.5 - Item 7 Means of egress lighting Identify on plans egress fixtures that function as both normal and emergency means of egress illumination; Provide calculation of lighting power density of total egress lighting; If total egress lighting power density is greater than 0.02 W/sq. ft., indicate on plans egress fixtures requiring automatic shut-off during unoccupied periods; Indicate method of automatic shut-off control C405.2.7 Exterior lighting controls Indicate on exterior lighting plans and fixture schedules the automatic lighting control method, control.sequence, and locations served; For building facade and landscape lighting, indicate automatic controls shut off lighting as a function of dawn/dusk and fixed opening/closing time; For all other exierior lighting, indicate automatic controls shut off lighting as a function of available daylight; include control sequence that also reduces lighting power by at least 30% between 12am-6am, or from 1 hour after closing to 1 hour before opening, or based upon motion sensor C405.5.1 Exterior building grounds lighting controls For building grounds fixtures greater than 100 watts, indicate on plans whether fixtures have efficacy greater than 80 lumens or; are controlled by motion sensor, or are exempt lighting per C405.5.2 C405.2.5 Area controls - Master control switches and circuit power limit Indicate location(s) of master control switch(es) intended to control multiple independent switches; circuit breaker may not be used as a master control switch; Verify that no 20 amp circuit controlled by a single switch or automatic control is loaded beyond 80% C406.4 Enhanced digital lighting controls To comply with additional efficiency package option, indicate on plans all interior lighting fixtures that are individually addressed and provided with continuous dimming, or exception taken; Include calculation of percent total installed interior lighting power that is configured with required enhanced lighting control functions (min 90% to comply with additional efficiency package option) C405.13 C408.3 Lighting system functional testing If claiming lighting system commissioning exemption provide supporting calculation; Identify applicable commissioning documentation requirements per Section C408 or eligibility for exception; Provide written procedures for functional testing of all automatic controls and describe the expected system response Lighting, Motor, and Electrical Permit Checklist, Pg. 3 • LTG-CHK 2015 Washington State Energy Code Compliance Forms for Commercial Buildings including R2, R3, R4 over 3 stories and all R1 Revised July 2016 Project Title: Cosco Fire Protection Date 8/4/2016 The following information is necessary to check a permit application for compliance with the lighting, motor, and electrical requirements in the Washington State Energy Code, Commercial Provisions. Applicability (yes,no,na) Code Section Component Compliance information required in permit documents Location in Documents Building Department Notes INTERIOR LIGHTING POWER & EFFICACY C405.4.1 C405.4.1 C405.4.2 Total connected interior lighting g g power Include all luminaires in lighting fixture schedule; indicate fixture types, lamps, ballasts, and manufacturer's rated watts per fixture; Identify spaces eligible for lighting power exemption on plans and in compliance forms; indicate the exception applied; Identify lighting equipment eligible for lighting power exemption in fixture schedule and in compliance forms; indicate the exception applied; Indicate that exempt lighting equipment is in addition to general area lighting and is controlled independently • C405.3 Exit signs Indicate location of exit signs on plans and rated watts per fixture in lighting fixture schedule (maximum 5 watts per fixture) C405.1 Lighting in dwelling units -lamp efficacy If high efficacy exception is applied to permanently installed lighting fixtures in dwelling units, indicate in lighting fixture schedule if lamps in fixtures are high efficacy per R404.1. Calculate percentage of fixtures with high efficacy lamps in project (min 75% to comply with exception). C406.3 Reduced lighting power density - dwelling unit lamp efficacy For project with dwelling units, to comply with additional efficiency package option indicate in lighting fixture schedule if lamps in fixtures have efficacy rating of 60 lumens per watt or more. Calculate percentage of fixtures with lamps that have this efficacy rating (min 95% to comply with option). Lighting Power Calculation - Indicate compliance path taken C405.4.2.1 Building Area Method Complete required compliance forms — proposed wattage per building area does not exceed maximum allowed wattage per building area. Identify locations of building areas on plans C405.4.2.2 Space-By-Space Method Complete required compliance forms — total proposed wattage does not exceed maximum allowed wattage. Identify locations of space types on plans, including retail display areas, lobby art & exhibit display areas, and ceiling heights as applicable C406.3 Reduced lighting power density To comply with additional efficiency package option, demonstrate in compliance forms that total connected interior lighting wattage is 75% less than the total maximum allowed lighting wattage via Building Area Method or Space-By-Space Method EXTERIOR LIGHTING POWER & EFFICACY C405.5.2 Total connected exterior lighting power Include all luminaires in lighting fixture schedule; indicate fixture types, lamps, ballasts, and manufacturer's rated watts per fixture; Identify exterior applications eligible for lighting power exemption on plans and in compliance forms; indicate exception applied; Indicate that exempt exterior lighting is controlled independently from non-exempt exterior lighting; include exception claimed for each fixture or group of fixtures under exception category Table C405.5.2(1) Exterior lighting zone Indicate building exterior lighting zone as defined by the AHJ C405.5.1 Exterior building grounds lighting For building grounds fixtures rated at greater than 100 watts that are complying based on efficacy, indicate rated lamp efficacy (in lumens per watt) in fixture schedule C405.5.2 Exterior lighting power calculations Complete required compliance form — proposed wattage for exterior lighting plus base site allowed does not exceed maximum allowed Lighting, Motor, and Electrical Permit Checklist, Pg. 4 LTG -CHK 2015 Washington State Energy Code Compliance Forms for Commercial Buildings including R2, R3, R4 over 3 stories and all R1 Revised July 2016 Project Title: Cosco Fire Protection Date 8/4/2016 The following information is necessary to check a permit application for compliance with the lighting, motor, and electrical requirements in the Washington State Energy Code, Commercial Provisions. Applicability (yes,no,na) Code Section Component Compliance information required in permit documents Location in Documents Building Department Notes MOTORS & TRANSFORMERS C405.6 Electrical tranformers Include electrical transformer schedule on electrical plans; indicate transformer size, efficiency, or exception taken C405.7 Dwelling unit electrical energy consumption Indicate on electrical plans that each dwelling unit in Group R-2 has a separate electrical energy meter C405.8 Electric motor efficiency Include all motors, including fractional hp motors, in electric motor schedule on electrical plans; indicate hp, rpm, rated efficiency, or exception applied C405.9.1 Elevator cabs For luminaires in each elevator cab, provide calculated average efficacy of combined fixtures that indicates efficacy is not less than 35 lumens per watt; Indicate rated watts per cfm for elevator cab ventilation fans do not exceed 0.33 watts per cfm; Indicate automatic controls that de -energize lighting and ventilation fans when elevator is stopped and unoocupied for a period of 15 minutes or more C405.9.2 Escalators and moving walks Indicate escalators comply with ASME A17.1/CSA B44; automatic controls are configured to reduce operational speed to the minimum permitted when not in use C405.9.3 Regenerative drive Indicate all one-way down or reversible escalators are provided with a variable frequency regenerative drive C405.10 Controlled receptacles Identify all controlled and uncontrolled receptables on electrical plans in each space in which they are required; include receptacle configuration such as spacing between controlled and uncontrolled, duplex devices, etc; Indicate on plans whether the method of automatic control for each controlled receptable zone is by occupant sensor or programmable time -of -day control If "no" is selected for any question, provide explanation: End of Lighting, Motor & Transformer Permit Documents Checklist PREVEW PLANI/ROUTING SLIP PERMIT NUMBER: D16-0229 DATE: 08/11/16 PROJECT NAME: COSTCO FIRE PROTECTION SITE ADDRESS: 4308 S 131ST PL X Original Plan Submittal Revision # before Permit Issued Response to Correction Letter # Revision # after Permit Issued DEPARTMENTS: kl Building Divisio tloilc$\111\11fili kNo PcmgiiVq1k) Fire Prevention P 1,1!2 hi) Rik. ivision Structural ❑ Permit Coordinator PRELIMINARY REVIEW: Not Applicable ❑ (no approval/review required) DATE: 08/16/16 Structural Review Required REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: Approved Corrections Required ❑ Approved with Conditions ❑ Denied (corrections entered in Reviews) (ie: Zoning Issues) DUE DATE: 09/13/16 Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire 0 Ping 0 PW 0 Staff Initials: 12/18/2013 PATTISON GENERAL CONTRACTOR Home Espafiol Contact Safety & Health 0 Washington State Department of Labor & Industries Claims & Insurance Search L&I A -Z Index Help Workplace Rights PATTISON GENERAL CONTRACTOR Owner or tradesperson Principals PATTISON, MICHAEL WINFIELD, PRESIDENT PATTISON, JAN LA REE LOUISE, VICE PRESIDENT Doing business as PATTISON GENERAL CONTRACTOR WA UBI No. 602 182 087 Parent company PATTISON INC 15235 NE 90th Street Bldg U REDMOND, WA 98052 425-497-8222 KING County Business type Corporation Governing persons JAN LL PATTISON MICHAEL W PATTISON; ZACHARY V MASON; License Verify the contractor's active registration / license / certification (depending on trade) and any past violations. Construction Contractor Active. Meets current requirements. License specialties GENERAL License no. PATTIGC917C7 Effective — expiration 02/27/2009— 02/27/2017 Bond ................. FIRST NAT INS CORP Bond account no. 6519060 Received by L&I 02/20/2008 Insurance ........................... Charter Oak Fire Ins Co Policy no. DTCO8G246583-15 Received by L&I 03/01/2016 $12,000.00 Effective date 02/27/2009 Expiration date Until Canceled $1,000,000.00 Effective date 02/24/2016 Expiration date 02/24/2017 Page 1 of 2 SEARCH' My L&I Trades & Licensing Help us improve https://secure.lni.wa.gov/verify/Detail.aspx?UBI=602182087&LIC=PATTIGC917C7&SAW= 9/6/2016 GENERAL NOTES ARCH/INTERIOR ABBREVIATIONS BUILDING SUMMARY PROJECT TEAM 1. CONTRACTOR SHALL COMPLY WITH THE CURRENT "GENERAL CONDET1ONS," AND BUILDING STANDARDS AS PROVIDED BY THE BUILDING OWNER. 2. GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR COORDINATING THE WORK OF DIFFERENT TRADES. 3. DO NOT SCALE DRAWINGS. CONTACT ARCHITECT FOR ANY MISSING DIMENSIONS. 4. CONTRACTOR INft1AATED CHANGES SHALL BE SUBMITTED IN WRITING TO THE OWNER AND ARCHITECT FOR APPROVAL PRIOR TO FABRICATION OR CONSTRUCTION. CHANGES SHOWN ON SHOP DRAWING ONLY WILL NOT SATISFY THIS REQUIREMENT. 5. ALL MODIFICATIONS, REQUIRING OWNER OR ARCHITECT APPROVAL WILL NOT BE VAUD UNLESS AUTHORIZED IN WRITING BY OWNER AND/OR ARCHITECT. 6. WITHIN FIVE (5) BUSINESS DAYS OF START OF CONSTRUCTION, THE CONTRACTOR SHALL NOTIFY IN WRITING BOTH THE ARCHITECT AND OWNER OF ANY ITEMS WHOSE ESTIMATE D DELIVERY TO THE SITE WOULD BE LATER THAN THAT REQUIRED FOR TIMELY INSTALLATION IN THE CONSTRUCTION SEQUENCE SUBSTITUTION OF ALTERNATE ITEMS WITH SHORTER LEAD TIMES, PAYMENT OF RUSH FABRICATION .OR DELIVERY CHARGES OUT OF SEQUENCE INSTALLATION, OR DELAY OF INSTALLATION OPTIONS TO BE AT THE SOLE APPROVAL OF OWNER OR ARCHITECT.DEMO 7. CONTRACTOR SHALL BE RESPONSIBLE FOR PROVIDING ALL WORK AND MATERIALS IN ACCORDANCE WITH THE LATEST LOCAL BUILDING CODES AND ORDINANCES. 8. CONTRACTOR SHALL VERIFY ALL AEU) DIMENSIONS AND CONDITIONS AND SHALL REPORT ANY CONFLICTS OR QUESTIONS FOR RESOLUTION BEFORE PROCEEDING WITH THE WORK. DO NOT SCALE THE DRAWINGS. 9. THE USE OF WORD "PROVIDE" SHALL ALWAYS MEAN, "FURNISH AND INSTALL, CONNECT, OR SECURE" AS REQUIRED. 10. ALL MATERIALS AND EQUIPMENT SHALL BE INSTALLED IN STRICT ACCORDANCE WITH MANUFACTURERS 10. ALL RNS ANDQ TRADE ASSOCIATESHACCEPTED STANDARDS.T 11. CONTRACTOR SHALL PROVIDE A WRITTEN CONSTRUCTION SCHEDULE. THIS SCHEDULE SHALL INCLUDE DELIVERY LEAD TIMES OF CONSTRUCTION ITEMS, AND START AND COMPLETION DATES OF EACH PHASE. THE CONTRACTOR SHALL UPDATE AND PROVIDE SUCH SCHEDULE ON A BIWEEKLY BASIS. 12. WORK MUST BE SCHEDULED WITH THE BUILDING MANAGEMENT TO AVOID DISRUPTION TO THE TENANTS. 13. ACCESS TO AND FROM THE PROJECT SITE, SPECIAL CONDITIONS, NOISY WORK, TIMING OF WORK, INTERRUPTION OF MECHANICAL AND ELECTRICAL SERVICES, RELOCATION OF EXISTING EQUIPMENT, CASEWORK, FIXTURES, FITTINGS, ETC., MUST BE COORDINATED WITH THE BUILDING MANAGEMENT. 14. ADEQUATE CLEANUP, PROTECTION AND PLACEMENT OF ANY CEILING TILES AND/OR OTHER DISRUPTION TO THE ADJACENT TENANT IMPROVEMENTS MUST BE REPLACED BEFORE BUSINESS HOURS OF THAT TENANT IN ORDER THAT THE OCCUPANT WILL NOT BE INCONVENIENCED IN THE NORMAL CONTINUATION OF THEIR OFFICE HOURS. 15. EACH SUBCONTRACTOR IS RESPONSIBLE FOR ANY DAMAGE TO ADJACENT WORK AND SHALL REPAIR SAID DAMAGE AT THEIR OWN EXPENSE. THIS INCLUDES ALL AREAS ON THE PREMISES SUCH AS: COMMON HALLWAYS, FREIGHT ELEVATOR VESTIBULES, ETC. 16. SCHEDULE THE USE OF THE ELEVATOR WITH BUILDING MANAGEMENT. 17. UPON COMPLETION OF ALL CONSTRUCTION, THE CONTRACTOR SHALL SUPPLY THE LANDLORD WITH ONE SET OF "RECORD" AS -BUILT DRAWINGS. 18. ALL MATERIALS TO BE NEW UON. 19. PATCH ALL DISTURBED AND/OR DAMAGED AREAS AS REQUIRED TO ACCOMPLISH NEW WORK AND AS REQUIRED FOR FINISHED APPEARANCE. 20. GENERAL CONTRACTOR IS RESPONSIBLE FOR PROVIDING ALL NECESSARYBACKING BLOCKING AND FRAMING FOR UGHT FIXTURES, ELECTRICAL FIXTURES, CASEWORK AND ALL OTHER ITEMS REQUIRING IT. 21. CONTRACTOR TO COORDINATE ALL ARE ALARM WORK WITH BUILDING OWNER. 22. ALL PAINT AND FINISH MATERIAL COLORS SHALL MATCH ARCHITECT'S CONTROL SAMPLES AND REQUIRE ARCHITECT'S REVIEW PRIOR TO INSTALLATION. SUBMIT TO ARCHITECT THREE (3) COPIES FOR REVIEW. 23. CONTRACTOR SHALL FURNISH SHOP DRAWINGS FOR REVIEW ON CABINETWORK, MILLWORK AND ANY1 OTHER SPECIAL ITEMS REQUIRING CUSTOM SHOP FABRICATION. SUBMIT TO ARCHITECT AT LEAST THREE (3) COPIES FOR REVIEW. 24. REPETITIVE FEATURES NOT FULLY SHOWN OR NOTED ON THE DRAWINGS SHALL BE COMPLETELY PROVIDED AS IF DRAWN IN FULL 25. THROUGHOUT THE DRAWINGS ARE ABBREVIATIONS WHICH ARE IN COMMON USE. THE UST OF ABBREVIATIONS PROVIDED IS NOT INTENDED TO BE A COMPLETE UST. THE ARCHITECT WILL DEFINE THE INTENT OF ANY IN QUESTION. ACT -ACOUSTIC CEIUNG TILE MECH -MECHANICAL ADJ -ADJUSTABLE MEZZ -MEZZANINE AFF -ABOVE FINISH FLOOR MFR -MANUFACTURER ALT -ALTERNATE MGMT -MANAGEMENT ALUM -ALUMINUM MGR -MANAGER APC -ACOUSTIC PANEL CEILING MIN -MINIMUM APPROX -APPROXIMATE MISC -MISCELLANEOUS ARCH -ARCHITECTURAL M.R. -MOISTURE RESISTANT AV -AUDIO VISUAL M/R -MOISTURE RESISTANT A/V -AUDIO VISUAL MTD -MOUNTED BLDG -BUILDING MIL -METAL- BOT -BOTTOM B/S -BUILDING STANDARD N/A -NOT APPLICABLE CAB -CABINET NIC -NOT IN CONTRACT CL -CENTER UNE NTS -NOT TO SCALECLG -CEILING OC ON CENTER - CLIC -CLEAR OFF -OFFICE COL -COLUMN OPNG -OPENING CONCF -CONFEREE OPP -OV RHEfE CONE -CONFERENCE OVD -OVERHEAD -DEMOLITION p -PAINT DEPT -DEPARTMENT PART -PARTITION DF -DRINKING FOUNTAIN PERF .-PERFORATED DIA -DIAMETER PERIM -PERIMETER DIFF -DIFFUSERPERP -PERPENDICULAR DIMM-DIMENSION NAM -PLASTIC LAMINATE DTL -DETAIL PLYWD -PLYWOOD DW -DISHWASHER PT -PRESSURE TREATED DWG -DRAWING PVC -POLYVINYL CHLORIDE (E) -EXISTING QTY -QUANTITY EA -EACH (R) -RELOCATED EL -ELEVATOR RA -RETURN AIR ELEC -ELECTRICAL RCP -REFLECTED CEILING PLAN ELEV-ELEVATION REC -RECESSED EQ -EQUAL REF -REFERENCE EQUIP -EQUIPMENT REFR -REFRIGERATOR EXT -EXTERIOR REL -RELOCATE FA -FIRE ALARM REV -REVISION OR REVISED FCIC -FURNISHED BY CONTRACTOR, RFG -REFRIGERATOR INSTALLED BY CONTRACTOR RM -ROOM FD -FLOOR DRAIN RO -ROUGH OPENING FE -FIRE EXTINGUISHER RTD -RATED FEC -FIRE EXTINGUISHER CABINET SCHED -SCHEDULE FFE -FINISH FLOOR ELEVATION SF -SQUARE FEET/FOOT AN -FINISH SHT -SHEET,, FLUOR -FLUORESCENT SIM -SIMILARCOPT FLR -FLOOR SPEC-SPECIRCA11ON FO -FACE OFy SPKR -SPEAKER FOIC -FURNISHED BY OWNER, INSTAU.ED SPKLR -SPRINKLER BY CONTRACTOR SQ -SQUARE FR -ARE RATED/RESISTANT/RETARDENT STD -STANDARD FTIC- -FURNISHED BY TENANT, INSTALLED STL -STEEL BY CONTRACTOR STG -STORAGE FURR -FURRING STOR -STORAGE G1S -GOOD ONE SIDED STRL -STRUCTURAL G2S -GOOD TWO SIDED STRUC -STRUCTURAL GA -GAUGE SYMM -SYMMETRICAL GC -GENERAL CONTRACTOR TBD -TO BE DETERMINED('Plumbing GL -GLASS TEL -TELEPHONE OR TELECOMGWB -GYPSUM WALL BOARD TEMP -TEMPERED GYP -GYPSUM THK -THICKNESS HC -HANDICAPPED TO -TOP OF HDW -HARDWARE TOS -TOP OF SLAB HM -HOLLOW METAL (STEEL FRAME) TYP -TYPICAL HR -HOUR UON -UNLESS OTHERWISE NOTED INCL -INCLUDED OR INCLUDING UPS -UNINTERRUPTED POWER SUPPLY• INFO • -INFORMATION VCT -VINYL COMPOSITION TILE INSUL -INSULATION VIF -VERIFY IN FIELD LAV -LAVATORY W/ -WITH LF -LINEAR FOOT WC -WATER CLOSET MAIL -MAXIMUMTERIAL WD -WOODATE- MAX -MAXIMUM WH -WATER HEATER MDF -MEDIUM DENSITY FIBERBOARD W/O -WITHOUT 1. PROJECT ADDRESS: COSCO FIRE PROTECTION 4308 SOUTH 131ST PLACE TUKWILA, WA 98124 2. APPLICABLE CODES & ORDINANCES: A BUILDING CODES INTERNATIONAL BUILDING CODE - 2015 B REGULATIONS & ORDINANCES NFPA C ACCESSIBILITY INTERNATIONAL BUILDING CODE - 2015 ICC/A117.1 ACCESSIBLE & USABLE BUILDINGS AND FACILITIES - 2009 3. GENERAL BUILDING DESCRIPTION: TENANT: GENERAL CONTRACTOR: COSCO FIRE PROTECTION T.B.D. 4308 SOUTH 131ST PLACE TUKWILA, WA 98124 PLUMBING ENGINEER: TEL: 206.438.3361 TBD - BIDDER DESIGN -BUILD BY G.C. ATTN: CATHERINE FERNANDO MECHANICAL ENGINEER: ARCHITECT/DESIGNER: TBD - BIDDER DESIGN -BUILD BY G.C. WEAVER ARCHITECTS, INC. 1411 - 4TH AVENUE, SUITE 810 ELECTRICAL ENGINEER: SEATTLE, WASHINGTON 98101 TBD - BIDDER DESIGN -BUILD BY G.C. TEL: 206.262.9622 FAX: 206.262.9507 FIRE/LIFE SAFETY ENGINEER: ATTN: PAUL GRUNDHOFFER TBD - BIDDER DESIGN -BUILD BY G.C. TYPE OF CONSTRUCTION: VB FIRE RESISTIVE SYSTEM: SPRINKLED OCCUPANCY TYPE: 'B' OFFICE DESCRIPTION 4. FIRE RESISTIVE CONSTRUCTION REQUIREMENTS: SHAFT ENCLOSURES: NA EXIT STAIR ENCLOSURES: NA CORRIDORS: NA PARCEL #7349200135 RIVERTON REPLAT LOTS 1 TO 5 LOTS 8, 9 & 10 LESS ST HWY TGW PORTION OF VACATED 43RD PLACE SOUTH ADJ - CITY OF TUKWILA ORDINANCE NO 1104 TGW LOTS 11, 12 & 13 LESS ST HWY TGW PORTION OF VACATED 44TH PLACE SOUTH ADJ - CITY OF TUKWILA ORDINANCE NO 1168 5• � APPROXIMATE AREA OF CONSTRUCTION: 2,426 SQ. FT. DRAWING INDEX TOTAL APPROXIMATE SUITE AREA: 16,340 SQ. FT. OCCUPANT LOAD FACTORS: \ DRAWING ISSUED OFFICE: 100 SQ. FT. / OCC. WAREHOUSE: 500 SQ. FT. / OCC. OFFICE 0 GROUND FLOOR: 4,400 SQ. FT. = 44 OCC. WAREHOUSE 0 GROUND FLOOR: 7,685 SQ. FT. = 16 OCC. OFFICE 0 MEZZANINE: 3,070 SQ. FT. = 31 OCC. DATE 08/04/16 cn `- o STORAGE 0 MEZZANINE: 1,185 SQ. FT. = 3 O:C. GENERAL NUMBER OF TOTAL PROPOSED OCCUPANTS: 94 TOTAL (60 GROUND FLOOR / 34 MEZZANINE) X X G.0.0 COVER SHEET / PROJECT INFORMATION NUMBER OF EXITS REQUIRED: 2 X X G.0.1 PROJECT NOTES MINIMUM EGRESS WIDTH REQUIRED: 3'-8" X X G.0.2 PROJECT NOTES COMMON PATH OF TRAVEL 100' SPRINKLED PER NFPA13 RCH AITECTURAL / INTERIORS 6. PROJECT DESCRIPTION: NON-STRUCTURAL INTERIOR TENANT IMPROVEMENT INCLUDING NEW PARTITIONS, DOORS, FINISHES AT THE X X A.1.1 DEMOUTION PLAN GROUND FLOOR. SEE 0.0.2 FOR AREA OF WORK. X X A.2A.1 CONSTRUCTION PLAN / DOOR SCHED. X X A.2B.1 REFLECTED CEILING PLAN w X X A.9.1 PARTITION TYPES / FRAMING DETAILS / CEIUNG DETAILS • Permit No, D1(/ ' 0?4,1 Plan review approval is subject to errors and omissions. Approval of construction documents does not authoiize the violation of any adopted code or ordinance. Receipt of approved Field Copy and conditions is acknowledged: By: SEPARATE REQUIRED el ErELectrical PERMIT FOR: M©chanical FOR REVIEW CE PLAN Co e. C y 'OI PiPP RV p1�G 2 2416 Date: A • �o • r /C� Gas Piping i 0 Ila City of Tukwila Ci BUILDING of Tukwila DIVISION 0 , Ct t31vlS1O� Buil. 1N BUILDING DIVISION SITE PLAN . 1 " -- 6 0' - - PROPERTY LINE - - - _ - - --- DUSTNG HYDR HYDRANT REVISIONS No changes shall be made to the scopePAVEMENT of I I EDGE - D E F I N I T I O N S 8c D I M E N S I O N S \ of work without prior approvalTukwila Building Division. , EXISTING BUILDING OUTUNE EXISTING a new submittal HYDRANT A. DEFINITIONS: NOTE: Revisions will require plan and may include additional plan review fees. 1. "TYPICAL" OR "TYP" INDICATES IDENTICAL COMPLETE SYSTEM FOR THE CONDITION NOTED. 2. "SIMILAR" OR "SIM." INDICATES COMPLETE SYSTEM AND COMPONENTS COMPARABLE TO THE CHARACTERISTICS FOR THE CONDITION NOTED. 3. "AS REQUIRED" INDICATES CONTRACTOR SHALL PROVIDE COMPONENTS REQUIRED TO COMPLETE THE NOTED SYSTEM AS INDICATED IN THE PROJECT DOCUMENTS. 4. "ALIGN" INDICATES ACCURATELY PROVIDE FINISH FACES OF MATERIALS IN STRAIGHT, TRUE, AND PLUMB RELATION ADJACENT MATERIALS. 5. "CLEAR" INDICATES CRITICAL DIMENSION AND SHALL SET PRECEDENT FOR LAYOUT OF PONS. B. DIMENSIONS: Y f 1 tt ; { '2 2 Ff :Z ., $£} �}F 1 3 d - 2 Fh'i✓ �}� Y llSSLSJ n .*l FW, ? tJ 5:f �1 44`n's" :! PAVEMENT EDGE SYMBOLS6.= C. ,cam - 1 uwuwwwu r S 11 o \ 1. DIMENSIONS ARE INDICATED TO THE FACE OF FINISHED SURFACE AT ALL NEW AND EXISTING CONSTRUCTION, CENTER OF COLUMNS OR GRID LINES UNLESS OTHERWISE NOTED. 2. ALIGNMENT OF PARTITIONS AND FINISHES AS SCHEDULED SHALL BE STRAIGHT, TRUE & PLUMB. DIMENSIONAL LAYOUT SHALL BE IN THE FOLLOWING PRIORITY ORDER. A.STRUCTURAL DRAWINGS B. LARGE SCALE DETAILS C. SMALL SCALE DE?AILS D. ENLARGED PLANS AND SECTIONS' E. FLOOR PLANS 3. MINIMUM DIMENSIONS FOR ACCFSSIBILTY CLEARANCES AND BUILDING CODE REQUIREMENTSPLACE SHALL BE MAINTAINED. 4. FLOOR ELEVATIONS ARE INDICATED AT THE FACE OF THE STRUCTURAL SLAB, UNLESS OTHERWISE NOTED. 5. VERTICAL DIMENSIONS ARE INDICATED FROM THE FLOOR ELEVATION TO FACE OF FINISHED " MATERIAL, UNLESS NOTED ABOVE FINISH FLOOR - AFF". 6. CEIUNG HEIGHTS ARE INDICATED FROM THE FLOOR ELEVATION TO THE FACE OF SUSPENDED ACOUSTIC COLING GRID OR FACE OF FINISH MATERIAL FOR OTHER CEILING TYPES, UNLESS OTHERWISE NOTED. 7. DOCUMENTS ARE DRAWN DIAGRAMMATICALLY, AND SCALED DIMENSIONS ARE APPROXIMATE. DIMENSIONS SHALL INDICATE REQUIRED SIZE, CLEARANCES, AND RELATIONSHIPS ARE INDICATED BY DIMENSIONS AS NOTED. ELEVATION REFERENCE SYMBOL INDICATES FINISHED + 1 SURFACES TO ALIGN U DETAIL ID DRAWING TITLE BAR O� HYDRANT 0 ►�0 - ^I- ^- i {} L A.06.XX R DETAIL IDENTIFICATION DRAWING TITLE G. N N EXISTING BUILDING OUTLINE \ 1 I 4308 SOUTH 131ST PLACE IVK'MLA� WA 98124 '� ( t a 4 s fw q £ { Y Y �1 ;f {� ` r f t PAVEMENT EDGE SHEET NO. D SECTION REFERENCE SYMBOL A TITLE GRAPHICAL SCALE O r . " DTL 1 FLOOR ELEVATION SYMBOLS ST 92'-0" +1'-0" NOMINAL FLOOR 41) DETAIL REFERENCE SYMBOL .l- ELEVATION HEIGHT (ABOVE/BELOW) DTL BUILDING SPACE / ROOM ID 'f'4'""""► CONSTRUCTION WORK SHALL NOT PROCEED UNTILH THE BUILDING OWNER / REPRESENTATIVE AND PAVEMENT I I 1 1 SHT --14- SPACE NAME BUILDING TENANT HAVE GIVEN THEIR APPROVAL TO EDGE THESE CONSTRUCTION DOCUMENTS. APPROVAL BY THESE PARTIES SHALL BE INTERPRETED AS \ ' OFFICE COLUMN AND/OR GRID UNE SYMBOL 1127 - -a*SPACE NUMBER DIMENSION LINE: 20' - 0" DOOR Q SYMBOL 'Z p APPROVAL OF DRAWINGS FOR CONTENT, FINISH SELECTIONS, SCOPE OF WORK, AND ALL DIMENSIONS REGARDED BY EITHER PARTY AS BEING NECESSARY \ PROPERTY UNE TO THEIR OPERATIONS, USE OF THE SPACE, FURNISHINGS, TENANT EQUIPMENT 7 AND AND FURNITURE INSTALLATIONS. •- CONSTRUCTION AND/OR INITIATION OF CONSTRUCTION, AUTHORIZED BY THE BUILDING SOUTH 131ST PLACE DOCUMENT SHEET SYMBOL 0 O L ANGLE ®- KEYED SHEET NOTES 0 OWNER FROM THESE CONSTRUCTION DOCUMENTS, BE INTERPRETED BY THE DESIGNER AS APPROVAL IN FULL OF THESE CONSTRUCTION DOCUMENTS BY BOTH THE BUILDING OWNER / REPRESENTATIVE AND THE TENANT. �- GLAZING SYMBOL © AT A Q CENTERLINE "'®- REVISION NUMBER ...00... ...e0m... e••••• • TENANT: COCO Fire Protection COSCO FIRE PROTECTION 4308 SOUTH 131ST PLACE TUKWILA, WA 98124 ARCHITECTS WEAVER ARCHITECTS, INC. 1411 FOURTH AVENUE, SUITE 810 SEATTLE, WASHINGTON 98101 P. 206.262.9622 F. 206.262.9507 All reproduction & intellectual property rights reserved c 2016 Approved by: Date: Professional seal REGISTERED ARCHITECT No. Issue Description Date REVIEW SET 08.05.16 PERMIT SET 08.11.16 Drawn by: PG Reviewed by: Project No: # 16-141-00 HW COVER SHEET / PROJECT INFORMATION Original drawing is 24" x 36". Scale entities accordingly if reduced G.0 n Permit Agency RECEIVED D CIT TUKWILA AUG 11 2016 PERMIT CENTER D (4o11A PROJECT NOTES DMSION I - GENERAL CONDMONS 01010 SUMMARY OF WORK 1. GENERAL DESCRIPTION OF THE PROJECT: NON-STRUCTURAL INTERIOR TENANT IMPROVEMENT OF A COMMERCIAL OFFICE SUITE. 2. WHERE NO BUILDING STANDARDS EXIST FOR MATERIALS CALLED OUT AS "BUILDING STANDARD" ON THE PLANS, THE CONTRACTOR SHALL SO ADVISE WEAVER ARCHITECTS WITHIN TEN (10) DAYS OF THE CONTRACTOR'S RECEIPT OF THE PLANS SO THAT WEAVER ARCHITECTS MAY MAKE ALTERNATE SELECTIONS. 3. CONTRACTOR SHALL VERIFY ALL REQUIREMENTS OF EXACT SIZE AND QUANTITY OF EQUIPMENT FURNISHED BY THE TENANT, INCLUDING REQUIREMENTS FOR MECHANICAL AND ELECTRICAL SERVICES, AND IS RESPONSIBLE FOR ALL ROUGH -IN CONNECTIONS. EACH SUBCONTRACTOR IS RESPONSIBLE FOR ANY DAMAGE TO ADJACENT WORK AND SHALL REPAIR SAID DAMAGE AT THEIR OWN EXPENSE. 4. FIRE/EMERGENCY SYSTEMS INCLUDE, BUT ARE NOT LIMITED TO, SPRINKLER MODIFICATIONS, FIRE EXTINGUISHER PLACEMENT, AUDIBLE ALARMS, SMOKE AND HEAT DETECTORS, STROBES, AND EXIT SIGN PLACEMENT. 5. MECHANICAL AND ELECTRICAL TO BE DESIGN -BUILD UNDER SEPARATE PERMIT. 6. WORK NOT INCLUDED: CONTRACTOR SHALL PROVIDE THE FOLLOWING ITEMS DESCRIBED IN THE SPECIFICATIONS AND SHOWN ON THE PLANS EXCEPT FOR THE ITEMS INDICATED "N.I.C." (NOT IN CONTRACT), SUCH AS TELEPHONE AND DATA CABLES, OFFICE FURNITURE, EQUIPMENT AND MOBILE KITCHEN APPLIANCES. 7. CONTRACTOR TO PROVIDE ALL FIRE/EMERGENCY SYSTEMS AS REQUIRED BY ALL APPLICABLE CODES. FIRE/EMERGENCY SYSTEMS INCLUDE BUT NOT LIMITED TO SPRINKLER MODIFICATIONS, FIRE EXTINGUISHERS, AUDIBLE ALARMS, STROBES, SPRINKLERS, SMOKE AND HEAT DETECTORS, AND EXIT SIGNS. 8. EVERY EXIT DOOR SHALL BE OPERABLE FROM THE INSIDE WITHOUT THE USE OF A KEY OR ANY SPECIAL KNOWLEDGE OR EFFORT, AND SHALL BE EQUIPPED WITH PANIC HARDWARE WHERE REQUIRED AND INDICATED. 9. ANY MATERIAL USED IN CONSTRUCTION SHALL MEET CURRENT FLAME CODE REGULATIONS. 10. ALL ELECTRICAL, PLUMBING AND MECHANICAL MATERIAL INSTALLATIONS SHALL COMPLY WITH THE BUILDING SHELL STANDARD SPECIFICATIONS. DMSION II - SITE WORK 02050 - DEMOLITION 1. FURNISH ALL LABOR, MATERIALS AND EQUIPMENT AS REQUIRED TO COMPLETE THE DEMOLITION AND REMOVAL OF ALL ITEMS LOCATED IN THE CONSTRUCTION AREAS. UPON COMPLETION OF ALL DEMOLITION WORK, ALL AREAS SHALL BE LEFT BROOM CLEAN. 2. DEMOLITION OF TELEPHONES, ELECTRICAL, VOICE/DATA AND PANELS ARE TO BE REMOVED BACK TO ORIGINATING SOURCE. DEMOLITION OF CORES AND RELATED CABLING TO BE REMOVED FROM TENANT SPACES BELOW. 3. DURING THE REMOVAL OF ANY ENVIRONMENTALLY HAZARDOUS MATERIALS, PROTECTION GUIDELINES SHOULD BE STRICTLY FOLLOWED BY CODE OR LOCAL GOVERNING AUTHORITY. 4. ALL EXISTING CONSTRUCTION ITEMS THAT INTERFERE WITH THE CONSTRUCTION NEGOTIATED BY THE PRICING PLAN / SPACE PLAN WITH WORK LETTER SHALL BE REMOVED, RELOCATED, OR KEPT FLUSH IN CEILING, WALL, OR FLOOR AS REQUIRED. 5. ALL DAMAGED AREAS SHALL BE PATCHED AS REQUIRED AND FINISHED TO MATCH EXISTING ADJACENT AREAS OR AS SPECIFIED TO PROVIDE A "LIKE -NEW FINISH". 6. CONTRACTOR SHALL PROVIDE PLASTIC SHEETING OR OTHER APPROPRIATE BARRIER TO CONTROL DUST AND DEBRIS SUCH THAT IT DOES NOT AFFECT AREAS OUTSIDE THE AREA OF WORK. DMSION VI - ARCHITECTURAL CARPENTRY AND CASEWORK 06100 - ROUGH CARPENTRY 1. ROUGH CARPENTRY TO INCLUDE ANY WOOD STUDS, FURRING, BLOCKING, ROUGH FRAMING, WOOD CURBS, BUCKS, NAILERS, BACKING, FIXTURE FRAMING, EQUIPMENT SUPPORTS, ETC. AS DETAILED. 06200 - FINISH CARPENTRY 1. FINISH CARPENTRY TO INCLUDE INSTALLATION OF ALL FIXTURES AND ASSOCIATED TRIMS, HARDWARE AND NOSINGS. 2. PROVIDE INTERIOR DOOR AND SIDELIGHT FRAMES AS SCHEDULED. 06400 - ARCHITECTURAL WOODWORK AND CASEWORK 1. CABINET CONSTRUCTION: COMPLY WITH THE A.W.I. ARCHITECTURAL WOODWORK QUAUTY STANDARDS FOR CUSTOM GRADE WORK. CABINETS SHALL BE FLUSH CONSTRUCTION. 2. PROVIDE PARTICLE BOARD, MED. DENSITY, WEIGHING <40 LB./CU. FT., AT LEAST 3/4" THICK. 3. CABINET HARDWARE: FULL EXTENSION DRAWER GLIDES, STAINLESS STEEL CABINET PULLS, US32D FINISH, AND CONCEALED DOOR HINGES, SHELF HARDWARE AND OTHER REQUIRED ITEMS, UON IN ELEVATIONS / DETAILS. 4. PLASTIC LAMINATE: HIGH-PRESSURE DECORATIVE LAMINATE SELECTED FROM WILSONART, NEVAMAR, PIONITE, AND FORMICA. LAMINATE TO BE GENERAL-PURPOSE GRADE .050" HORIZONTAL AND .030" VERTICAL. 5. INTERIOR CABINET SURFACES AND SHELVES TO BE OF PREFINISHED BOARD WITH POLYESTER OVERLAY. 6. SHELF EDGING TO BE VINYL TO MATCH EXTERIOR LAMINATE FINISH. 7. ALL EXPOSED CABINETS SIDES SHALL BE FINISHED IN PLASTIC LAMINATE TO MATCH CABINET FRONT. 8. SUBMIT SHOP DRAWING SUBMITTALS FOR ARCHITECT REVIEW. DIVISION VIII - DOORS AND WINDOWS 08210 - WOOD DOORS 1. PROVIDE AND INSTALL INTERIOR SUITE DOORS AS INDICATED ON DRAWINGS. 2. DOOR SCHEDULE SPECIFIES FINISH (BOTH SIDES OF DOOR) AND FRAME, UON. 3. DOORS SHALL BE PRE -MACHINED FOR HARDWARE PER HARDWARE SCHEDULE. 4. SUBMIT SHOP DRAWING SUBMITTALS FOR ARCHITECT REVIEW. 08710 - FINISH HARDWARE 1. FINISH AND SPECIALTY HARDWARE INCLUDES ALL ACCESSORIES, TOOLS, AND FASTENERS REQUIRED FOR HARDWARE INSTALLATION AND MAINTENANCE. ITEMS NOT SPECIFICALLY MENTIONED, BUT NECESSARY TO COMPLETE THE WORK, SHALL BE FURNISHED MATCHING IN QUALITY AND FINISH OF SPECIFIED IN SIMILAR LOCATIONS. 2. PROVIDE ALL HARDWARE AS SPECIFIED PER THE HARDWARE SCHEDULE. 3. ALL LOCK SETS SHALL CONFORM TO THE BUILDING'S GRAND MASTER KEYING SYSTEMS. PROVIDE TWO (2) KEYS FOR EACH LOCK AND TWO (2) MASTER KEYS FOR THE SUITE. ALL KEYS TO BE TAGGED WITH ROOM NUMBERS. CONFIRM QUANTITY WITH BUILDING MANAGEMENT. 4. SUBMIT HARDWARE SCHEDULE WITH CATALOGUE CUT SHEETS FOR ARCHITECT REVIEW. 5. ALL DOORS SHALL HAVE A MINIMUM OF 1-1/2 PAIR OF BUTT HINGES, ONE LATCHSET OR LOCK SET, AND ONE DOOR STOP TO MEET ACCESSIBIUTY REQUIREMENTS. 6. ALL HARDWARE SHALL BE COMMERCIAL GRADE. 7. PROVIDE CLOSERS PER HARDWARE SCHEDULE AND AT ALL RATED ASSEMBLIES. . 08810 - GLASS 1. ALL GLASS AT SIDEUGHTS AND DOORS SHALL BE 1/4" TEMPERED SAFETY GLAZING, UON. 2. THIS PROJECT CONTAINS GLAZING THAT WILL BE SUBJECT TO FEDERAL GLAZING STANDARDS. GLAZING SUBCONTRACTOR SHALL BE RESPONSIBLE FOR ADHERENCE TO THE REQUIREMENTS. IF GLAZING SUBCONTRACTOR FINDS ANYTHING IN THE DOCUMENTS NOT IN COMPLIANCE WITH THE STANDARD, THEY SHALL BRING DISCREPANCIES TO THE ATTENTION OF THE ARCHITECT BEFORE PROCEEDING WITH THE WORK. DMSION IX - FINISHES 09250 GYPSUM DRYWALL AND METAL STUDS 1. INCLUDE NECESSARY MATERIALS, LABOR AND ACCESSORIES FOR THE INSTALLATION OF ALL PARTITIONS AS SHOWN IN THE PLANS. 2. "WALL SURFACES" MEAN ALL VERTICAL SURFACES INCLUDING COLUMNS WHERE EXPOSED, CONVECTOR OR RADIATOR ENCLOSURES, FASCIAS, RETURNS, PLYWOOD BACKBOARDS, ETC. 3. ALL PARTITION HEADS SHALL MATCH BUILDING STANDARD, UON. 4. WALLS SHOWN ALIGNED WITH BASE BUILDING STRUCTURE SHALL BE FLUSH AND SMOOTH WITH BASE BUILDING STRUCTURE, UON. 5. SEISMIC BRACING: PROVIDE SEISMIC BRACING AS REQUIRED PER THE LATEST BUILDING CODES (NEW CONSTRUCTION ONLY) TO THE PARTITION HEADS AND CEILING GRID. 6. FRAMING STUDS: GALVANIZED STEEL STUDS PER CONSTRUCTION PLANS. PROVIDE WITH SHEET METAL BACKING WITHIN ALL WALLS RECEIVING CASEWORK (CABINETS, BOOKSHELVES, ETC.). VERIFY STUD SIZE MATCHES DOOR FRAMES IN STOCK IF APPLICABLE. 7. CONTRACTOR SHALL PROVIDE AND LOCATE ACCESS PANELS AS REQUIRED AFTER INSTALLATION OF MECHANICAL DUCTS, PLUMBING, AND ELECTRICAL WORK. FIRE RATE AS REQUIRED. 8. ALL DRYWALL TO BE 5/8" TYPE "X" UNLESS OTHERWISE NOTED. PROVIDE "M/R" TYPE DRYWALL WHERE REQUIRED BY CODE AND AT ALL TOILET ROOMS, AND BEHIND CERAMIC TILES, UON. 9. INSTALL CORNER BEADS AT ALL EXTERNAL CORNERS. INSTALL METAL EDGE TRIM WHENEVER EDGE OF GYPSUM BOARD WOULD OTHERWISE BE EXPOSED OR SEMI -EXPOSED. 10. PRIOR TO RECEIVING FINISH, ALL SURFACES SHALL BE PROPERLY PREPARED AS REQUIRED TO RECEIVE FINAL FINISHING AS SPECIFIED. 11. EXTEND ALL SOFFIT FRAMING TO STRUCTURE ABOVE. PROVIDE DIAGONAL BRACING AS NECESSARY. 12. PROVIDE FRAMING FOR SUSPENDED CEILING WITH SEISMIC BRACING IN ACCORDANCE WITH REQUIREMENTS OF APPLICABLE CODES AND AS SHOWN ON DRAWINGS. 13. USE ACOUSTICAL SEALANT AROUND ALL PIPES, DUCTS, CONDUIT, OUTLETS, SWITCHES ETC. ON BOTH SIDES OF CROSSING/PENETRATING WALLS WITH ACOUSTICAL INSULATION. PENETRATIONS OF FIRE -RATED WALLS SHALL BE PROTECTED BY APPLICABLE FIRE -RATED ASSEMBLIES. 09500 - CEILING SUSPENSION SYSTEMS. 1. PROVIDE NEW CEILING TILE, CEILING GRID AND ALL ACCESSORIES AS REQUIRED TO INSTALL SUSPENDED ACOUSTICAL CEILINGS AS INDICATED ON DRAWINGS. 2. PROVIDE SEISMIC BRACING AS REQUIRED BY CODE AT NEW CEILING WORK ONLY. 3. COORDINATE WORK WITH OTHER TRADES HAVING WORK IN THE CEILING AND THE TELEPHONE AND DATA CABLE COMPANIES WHEREVER THEIR RESPECTIVE WORK IS CONTIGUOUS. 4. PROVIDE CUTOUTS AND OTHER SPECIAL PROVISIONS IN ACOUSTICAL WORK AS REQUIRED FOR LIGHTING FIXTURES, REGISTERS, DIFFUSERS, SPRINKLERS, AND OTHER INSERTED ITEMS. 5. ALL CUTOUTS SHALL BE CENTERED WITHIN ACOUSTIC CEIUNG TILE, UON. 6. ALL MATERIALS SHALL HAVE CLASS 1 FLAME SPREAD RATING AND BE INSTALLED IN ACCORDANCE WITH MANUFACTURER'S SPECIFICATION AND CODES. 7. ALL JOINTS IN THE TILE FIELD SHALL BE SQUARE, LEVEL AND PERFECTLY ALIGNED WITH EACH OTHER. 8. INSTALLED SUSPENDED CEILINGS TO BE LEVEL WITHIN A TOLERANCE OF 1/8" IN 12'-0". ANCHOR AS REQUIRED. 09530 - ACOUSTICAL TREATMENT 1. PROVIDE ACOUSTICAL INSULATION BETWEEN FRAMING STUDS AND EXTENDING TWO FEET ON EACH SIDE OF PARTITION HEAD ABOVE CEILINGS FOR ALL WALLS NOTED PER PLANS. 2. NEW DEMISING WALL CONSTRUCTION TO HAVE SOUND BATT INSULATION BETWEEN FRAMING STUDS AND TWO FEET OF INSULATION ON EITHER SIDE OF THE PARTITION HEAD ABOVE CEILING GRID. 09650 - RESILIENT FLOORING 1. PROVIDE VCT, SHEET LINOLEUM, SHEET VINYL AND RUBBER BASE AS INDICATED IN DRAWINGS. COLOR AND MANUFACTURER PER FINISH SCHEDULE. 2. PROVIDE RUBBER -REDUCING STRIPS IN COLOR TO MATCH SPECIFIED BASE. REDUCING STRIPS TO OCCUR AT ALL AREAS OF FLOOR MATERIAL TRANSITION. 3. BASE TO BE INSTALLED IN LONGEST AVAILABLE LENGTH WITH NO PIECE LESS THAN 12". NO JOINTS AT OUTSIDE CORNERS OR WITHIN 6" OF CORNERS. 4. PATCH, LEVEL AND PREPARE SUB FLOORING WITH CEMENTITOUS UNDERLAY PER MANUFACTURER'S WRITTEN INSTRUCTIONS IN AREAS TO RECEIVE NEW FLOORING. MAX. ALLOWABLE TOLERANCE = 1/4" OVER 10'. 5. UPON COMPLETION ALL WORK SHALL BE CLEANED AND ALL SPOTS OF ADHESIVE AND SURFACE STAINS REMOVED. 6. GENERAL CONTRACTOR SHALL APPLY FLOOR WAX TO NEW FLOORING AREAS PER MANUFACTURERS SPECIFICATION UON. 09680 - CARPET 1. PROVIDE COMMERCIAL GRADE CARPET AS INDICATED IN DRAWINGS. 2. CARPET TO BE INSTALLED AS INDICATED IN DRAWINGS. 3. PREPARE SUB FLOOR WITH LIGHT WEIGHT CONCRETE UNDERLAY WHERE REQUIRED TO PROVIDE APPROVED SUBSTRATE. MAX. ALLOWABLE TOLERANCE = 1/4" OVER 10'. 4. PROVIDE SEAMING DIAGRAMS FOR ARCHITECT'S REVIEW. 09900 - PAINTING AND STAIN 1. UNLESS OTHERWISE NOTED, PRIME ALL GWB WALL SURFACES AND PAINT WITH MINIMUM OF TWO (2) FINISH COATS OF BENJAMIN MOORE EGGSHELL FINISH LATEX PAINT OR APPROVED EQUAL. PRCVIDE FOR NUMBER OF PAINT COLORS AS INDICATED IN DRAWINGS. 2. FINISH DOORS, DOOR FRAMES, AND SIDELIGHT FRAMES AS INDICATED IN DRAWINGS. A) PAINTED WOODWORK TO BE FINISHED WITH ONE (1) COAT PRIMER AND TWO (2) FINISH COATS. 8) SEALED WOODWORK TO BE STAINED PER FINISH SCHEDULE AND SEALED WITH A COMMERCIAL GRADE CLEAR SATIN VARNISH. 3. PAINT FOR THE UGHT SURFACES TO CONFORM TO THE REQUIREMENTS OF THE "ARCHITECTURAL SPECIFICATIONS MANUAL" (AWS) FOR PAINT SYSTEMS. LATEX PAINT: AWS SYSTEM 3-B "CUSTOM" (2 COAT) GRADE LIGHT COLOR PAINT FINISH ON GYPSUM BOARD SURFACES. 4. PAINT FOR THE DARK SURFACES TO CONFORM TO THE REQUIREMENTS FOR THE "ARCHITECTURAL SPECIFICATIONS MANUAL" (AWS) FOR PAINT SYSTEMS. LATEX PAINT: AWS SYSTEM 3-B "CUSTOM" (2 COAT) GRADE DEEP TONE PAINT FINISH ON GYPSUM BOARD SURFACES. 5. UPON COMPLETION OF WORK, REMOVE EXCESS PAINT, STAIN, VARNISH, ADHESIVE, CAULK, ETC. FROM ALL OTHER SURFACES THAT WERE NOT SPECIFIED TO RECEIVE SAME. 6. TOUCH-UP AND PATCH SURFACES AS REQUIRED AFTER THE COMPLETION OF WORK BY OTHER TRADES. 7. WHERE COLUMNS OCCUR IN AREAS SCHEDULED TO BE FINISHED, THEY SHALL RECEIVE THE SAME FINISH AS THE ROOM UON. DMSION XII - FURNISHINGS 12500 - WINDOW TREATMENT 1. ALL EXISTING INTERIOR AND PERIMETER MINI BLINDS TO BE BAGGED AND CLEANED TO LIKE -NEW CONDITION. DMSION XV - MECHANICAL 15400 - PLUMBING 1. PROVIDE SUPPLY, WASTE AND VENT LINES, VALVES, FITTINGS, ETC. REQUIRED FOR KITCHEN SINKS, DISHWASHER, REFRIGERATOR, AIR CONDITIONING UNIT(S), VENDING MACHINES, COFFEE MAKER, WATER HEATERS, ETC. 2. ALL FIXTURE INSTALLATIONS SHALL CONFORM TO THE AMERICANS WITH DISABILITIES ACT. 3. PROVIDE NEW PLUMBING FIXTURES AS SPECIFIED PER DRAWINGS. 4. PROVIDE HOT AND COLD WATER TO SINKS/DISHWASHERS. 5. ALL NEW WATER HEATERS ARE TO BE INSTALLED WITH DRIP PAN CONNECTED TO WASTE LINE. 6. ALL PLUMBING FIXTURES ARE TO BE INSTALLED TO MEET CURRENT GOVERNING LOCAL AND FEDERAL CODES. 7. CONTRACTOR PROVIDE INSTALLATION DESIGN DOCUMENTS TO ARCHITECT AND BUILDING OWNER FOR REVIEW AND APPROVAL PRIOR TO INSTALLATION. 15500 - FIRE PROTECTION 1. FIRE PROTECTION SYSTEM PER BUILDING STANDARD, LOCAL REGULATIONS AND ORDINANCES. 2. PROVIDE ALL EMERGENCY LIGHTING, EXIT SIGNS, FIRE ALARM SPEAKERS, STROBES AND BELLS AS REQUIRED BY CODE. DESIGN AND INSTALL THE SAME IN COMPLIANCE WITH THE AMERICANS WITH DISABIUTIES ACT. 3. PROVIDE SPRINKLERS, FIRE RATED DOORS AND FRAMES, FIRE EXTINGUISHERS, ETC. AS REQUIRED BY APPLICABLE LOCAL CODES AND LAWS. 4. FIRE EXTINGUISHERS SHALL BE BY UNDERWRITER'S LABORATORY 2A-10BC 5 -LB, MULTIPURPOSE EXTINGUISHER WITH SQUEEZE -TYPE HANDLE AND FLEXIBLE DISCHARGE HOSE WITH VISIBLE PRESSURE GAUGE. 5. FIRE EXTINGUISHERS SHALL BE INSTALLED PER BUILDING STANDARD REQUIREMENTS, UON. 6. DESIGN -BUILD FIRE PROTECTION DRAWINGS INDICATE: A. LAYOUT, LOCATION, AND SIZE OF SPRINKLER UNES AND HEADS. B. PRESSURE REQUIREMENTS. C. SPRINKLER HEAD SPECIFICATIONS. D. LOCATION OF FIRE PROTECTION RISERS AND WALL HYDRANTS 7. CONTRACTOR TO PROVIDE INSTALLATION DESIGN DOCUMENTS TO ARCHITECT AND BUILDING OWNER FOR REVIEW AND APPROVAL PRIOR TO INSTALLATION. 8. ALL SPRINKLER HEADS SHALL BE CENTERED IN ACOUSTICAL CEIUNG TILE, UON. 15800 - HEATING VENTILATING AND AIR CONDITIONING 1. PROVIDE BUILDING STANDARD HVAC SYSTEM WITH ALL MATERIALS, LABOR AND ACCESSORIES FOR COMPLETE OPERATION OF SYSTEM. CONTRACTOR TO BALANCE HVAC SYSTEM AS REQUIRED. 2. DESIGN OF MECHANICAL TO BE PREPARED UNDER A SEPARATE PERMIT. 3. DESIGN -BUILD MECHANICAL ENGINEERING DRAWINGS INDICATE: A. DUCTS, AIR MOVEMENT REQUIREMENTS, & SIZES OF GRILLES & REGISTERS. 4. CONTRACTOR TO PROVIDE INSTALLATION DESIGN DOCUMENTS TO ARCHITECT AND BUILDING OWNER FOR REVIEW AND APPROVAL PRIOR TO INSTALLATION. 5. HVAC CONTRACTOR TO CLEAN, REPAIR OR REPLACE SOILED OR DAMAGED HVAC GRILLS, FILTERS AND THERMOSTATS. 16000 - ELECTRICAL AND TELECOMMUNICATIONS 1. REUSE EXISTING ELECTRICAL AND DATA AS APPROPRIATE TO MEET THE TENANT'S REQUIREMENTS. REPLACE OUTLET COVERPLATES TO MATCH NEW FINISH IF APPLICABLE. 2. PROVIDE ALL WORK, EQUIPMENT AND LABOR FOR A COMPLETE AND OPERABLE ELECTRICAL SYSTEM. PROVIDE ELECTRICAL OUTLETS PER POWER AND DATA PLAN. 3. PROVIDE MUDRING FOR DATA AND COMMUNICATION AS SHOWN ON THE POWER AND DATA PLAN. EACH MUDRING TO HAVE A MINIMUM NUMBER OF WIRE PULLS AS INDICATED ON DRAWINGS. COORDINATE DATA CABLE CONFIGURATION WITH THE TENANT. 4. ALL OUTLETS AND MUDRINGS TO BE LOCATED AT 18" AFF TO THE CENTER LINE, UON. 5. WHERE MULTIPLE DEVISES OCCUR IN A SINGLE LOCATION, ALL DEVICES SHALL BE GANGED UON. 6. ALL ELECTRICAL OUTLETS WITHIN THE CODE REQUIRED DISTANCE FROM A SINK SHALL BE ON A GROUND FAULT INTERRUPTED CIRCUIT. 7. ALL WIRING DEVICES: SHALL BE BUILDING STANDARD EXCEPT: "ISOLATED GROUND" OUTLETS SHALL BE ORANGE, "HOSPITAL GRADE ISOLATED GROUND" OUTLETS SHALL BE ORANGE WITH A GREEN DOT, "EMERGENCY" OUTLETS SHALL BE RED, AND "DEDICATED" OUTLETS FOR "CLEAN CIRCUIT" FIXTURES SHALL BE GRAY (UNLESS BUILDING STANDARD DICTATES OTHERWISE). ALL COVERPLATES SHALL BE BUILDING STANDARD FINISH, UON. 8. PROVIDE SEPARATE CIRCUITS FOR TENANT'S EQUIPMENT (INCLUDING THE TELEPHONE SWITCH, COPIERS, COMPUTERS, ETC.) WHEN NOTED ON THE CONSTRUCTION DOCUMENTS. 9. COORDINATE SCHEDULE WITH FURNITURE VENDOR FOR THE USE OF ELECTRICIANS DURING THE INSTALLATION OF TENANT'S NEW FURNITURE. 10. ALL ELECTRICAL WIRING, TELEPHONE AND COMPUTER CABLING, AND CONDUIT SHALL BE CONCEALED IN FLOORS, WALLS, OR CEILINGS. CABLING FOR VOICE AND DATA TO BE PROVIDED BY TENANT'S VENDORS AND SHALL BE COORDINATED BY THE BUILDING MANAGER. 11. THE CONTRACTOR IS TO COORDINATE WITH THE OWNER SUPPLIED FURNITURE SYSTEMS TO INCLUDE BUT NOT LIMITED TO: ELECTRICAL AND DATA WIRING LOCATIONS, J -BOX LOCATIONS, CONNECTIONS AND WALL MOUNTED REQUIREMENTS. 12. THE CONTRACTOR IS TO VERIFY EXISTING ABANDONED CORE DRILL LOCATIONS AND FILL AS REQUIRED WITH MATERIAL TO MEET CURRENT FLAME SPREAD REGULATIONS. LOCATIONS TO BE PREPARED TO RECEIVE NEW FLOOR FINISH AS REQUIRED. 13. ARCHITECTURAL DRAWINGS INDICATE LOCATION ONLY OF DEVICES SHOWN. SWITCHING AND CIRCUITING SHALL BE INDICATED ON SEPARATE ELECTRICAL ENGINEERING AS -BUILT DRAWINGS AND SHALL MEET OWNER'S GUIDELINES. 14. ALL TELEPHONE, ELECTRICAL, COMMUNICATION AND SECURITY WORK SHALL BE COMPLETED IN ACCORDANCE WITH ALL APPLICABLE CODES. 15. DRAWINGS INDICATE ALL DIMENSIONS TO CENTERUNE OF TELEPHONE, ELECTRICAL, AND COMMUNICATION COVERPLATE. OUTLETS SHOWN GROUPED TOGETHER ON PLAN SHALL BE SET TO A MINIMUM DIMENSION BETWEEN EACH DEVICE. 16. BACK-TO-BACK OUTLETS ARE NOT PERMITTED. OFFSET OUTLETS THE MINIMUM DIMENSION REQUIRED. 17. LOCATION OF ALL WALL MOUNTED POWER AND DATA DEVICES SHALL BE FIELD REVIEWED BY THE ARCHITECT BEFORE INSTALLATION. 18. ELECTRICAL ENGINEER TO PROVIDE DESIGN -BUILD PACKAGE TO ARCHITECT FOR REVIEW PRIOR TO INSTALLATION. 19. THE LAYOUT DIAGRAMS COORDINATE LOCATION OF POWER & DATA DEVICES. REFER TO DESIGN -BUILD DOCUMENTS FOR SCOPE, TECHNICAL LAYOUT AND SPECIFICATIONS FOR EACH DISCIPLINE. 20. ARCHITECTS DOCUMENTS INDICATE LOCATION AND RELATIONSHIP OF DEVICES. COORDINATE EXACT LOCATION WITH FURNITURE VENDOR. 21. COORDINATE POWER/DATA, FIRE SAFETY DEVICES & LIGHT FIXTURE MOUNTING LOCATIONS WITH INTERIOR ELEVATIONS, FINISHES & CASEWORK. 22. PROVIDE EXTENSION RINGS AND MOUNTING ACCESSORIES WHERE REQUIRED FOR POWER/DATA DEVICES AND LIGHT FIXTURES. COORDINATE WITH INTERIOR FINISHES AND CASEWORK. 23. CONTRACTOR TO PROVIDE INSTALLATION DESIGN DOCUMENTS TO ARCHITECT AND BUILDING OWNER FOR REVIEW AND APPROVAL PRIOR TO INSTALLATION. 16500 - LIGHTING 1. LOCATION OF SWITCHES SHALL BE SHOWN ON THE REFLECTED CEIUNG PLAN. ALL SWITCHES SHALL BE MOUNTED AT A MAXIMUM , HEIGHT OF 48" A.F.F. TO MEET THE LATEST ACCESSIBILITY CODES AND REGULATIONS. 2. WHERE MULTIPLE SWITCHES OCCUR IN A SINGLE LOCATION, ALL SWITCHES SHALL BE GANGED UON. 3. DOWN LIGHTS SHOWN IN THE CENTER OF CEILING TILE WITHOUT DIMENSIONS ARE TO BE LOCATED IN THE CENTER OF CEILING TILE, UON. 4. REUSE ALL EXISTING B/S FLUORESCENT FIXTURES AS NEEDED PER DESIGN LAYOUT AND TO MEET LOCAL ENERGY CODE COMPLIANCE. VERIFY OR PROVIDE NEW LAMPS AND REPLACE FAULTY BALLASTS. 5. DESIGN OF ELECTRICAL TO BE PREPARED UNDER A SEPARATE PERMIT AS A DESIGN BUILD PROJECT. PERMIT DRAWINGS TO BE REVIEWED AND APPROVED IN WRITING BY LANDLORD PRIOR TO COMMENCEMENT OF WORK. 6. ALL OFFICE AREAS LESS THAN 300 SQ. FT. ENCLOSED BY WALLS OR CEIUNG-HEIGHT PARTITIONS, AND ALL MEETING AND CONFERENCE ROOMS, SHALL BE EQUIPPED WITH OCCUPANCY SENSORS, PER CODE. 7. DESIGN BUILD ELECTRICAL ENGINEERING DRAWINGS INDICATE: A. CIRCUITING AND WIRING OF LIGHT FIXTURES, AND SWITCHES. B. LIFE SAFETY EQUIPMENT. C. LOCATION OF REQUIRED EMERGENCY LIGHT FIXTURES. D. LIGHT FIXTURE SPECIFICATIONS 8. CONTRACTOR TO PROVIDE INSTALLATION DESIGN DOCUMENTS TO ARCHITECT AND BUILDING OWNER FOR REVIEW AND APPROVAL PRIOR TO INSTALLATION. . * 00... *10 COSCO Fire Protection TENANT: COSCO FIRE PROTECTION 4308 SOUTH 131ST PLACE TUKWILA, WA 98124 ARCHITECTS WEAVER ARCHITECTS, INC. 1411 FOURTH AVENUE, SUITE 810 SEATTLE, WASHINGTON 98101 P. 206.262.9622 F. 206.262.9507 All reproduction & intellectual property rights reserved c 2016 REVIEWED FOR CODE COMPLIANCE APPROVED AUG 2 6 2016 City of Tukwila BUILDING DIVISION Professional seal i 8109 REGISTERED ARCHITECT . WEAVER OF WASHINGTON 111/11-7 No. Issue Description Date REVIEW SET 08.05.16 PERMIT SET 08.11.16 Drawn by: HW Reviewed by: Project No: # 16-141-00 PG PROJECT NOTES Original drawing is 24" x 36". Scale entities accordingly if reduced G.0.1 Permit Agency CITYEIVED OF TUKWILA AUG 11 2016 PERMIT CENTER EXISTING SUITE EXPANSION SUITE 3,735 SQ. FT. STORAGE: 8 OCCUPANTS GROUND FLOOR S-1 OCCUPANCY TOTAL 7,685 SQ. FT. = 16 OCC. S-1 OCCUPANCY: 1 MAXIMUM COMMON PATH OF TRAVEL 50' -0 - i (MOUND FLOOR 8 OCCUPANCY TOTAL 4,400 SQ. FT. = 44 OCC. . . GROUND FLOOR EGRESS PLAN 0 16' 32' 48' 1/16" = 1'- 0" EXISTING SUITE EXPANSION SUITE 2,426 SQ. FT. OFFICE: 25 OCCUPANTS AREA OF WORK LIMITED TO GROUND FLOOR OFFICE AREA SHOWN OCCUPANCY INFORMATION KEYED SHEET NOTES OCCUPANT LOAD FACTORS: HATCH SIGNIFIES EGRESS PATH, LIGHT FIXTURES TO PROVIDE EMERGENCY LIGHTING TO ALLOW FOR UGHT LEVEL COMPLYING WITH IBC OFFICE: 100 SQ. FT. / OCC. O SECTION 1006.4. SEE A.2B.1 FOR ADDITONAL INFORMATION. WAREHOUSE: 500 SQ. FT. / OCC. OFFICE 0 GROUND FLOOR: 4,400 SQ. FT. = 44 OCC. O HATCH SIGNIFIES MECHANICAL PLATFORM AND ROOF ACCESS PLATFORM WITH EXISTING GUARDRAIL PERIMETER TO REMAIN AS IS. WAREHOUSE 0 GROUND FLOOR: 7,685 SQ. FT. = 16 OCC. OFFICE 0 MEZZANINE: 3,070 SQ. FT. = 31 OCC. O AREA SIGNIFIES UNUSED INACCESSIBLE EXISTING PLATFORM AREA TO REMAIN AS IS. STORAGE 0 MEZZANINE: 1,185 SQ. FT. = 3 OCC. NUMBER OF TOTAL PROPOSED OCCUPANTS: 94 TOTAL (60 GROUND FLOOR / 34 MEZZANINE) O EXISTING CHAIN UNK STORAGE AREA TO REMAIN NUMBER OF EXITS REQUIRED: 2 MINIMUM EGRESS WIDTH REQUIRED: 3'-8"DOOR SERVES AN OCCUPANT LOAD LESS THAN 50 OCCUPANTS (44 OCCUPANTS FROM GROUND LEVEL EXPANSION OFFICE SPACE AND 3 O COMMON PATH OF TRAVEL: 100' SPRINKLED PER NFPA13 OCCUPANTS FROM STORAGE MEZZANINE) EXISTING SUITE GROUND FLOOR BELOW EXPANSION SUITE OP TO GROUND OOR BELOW OPEN TO GROUND FLOOR BELOW OFFICE AREA 0 MEZZ., 3,070 SQ. FT. = 31 OCC. 'fir: AV, p TAIME ECOMMOW MtmotiACCIN /////// ///// / / // // // ii%��i �i�T�i,�i���i, EXISTING MEZZANINE S OCCUPANCY: 1 OPEN TO WAREHOUSE MEZZANINE 1 AREA BELOW EH 1,185 SQ. FT. = 3 OCC. STORAGE USE MEZZANINE LEVEL EGRESS PLAN 0 16' 32' 48' 1/16" = 1'- 0" EXISTING SUITE EXPANSION SUITE 1,185 SQ. FT. STORAGE: 3 OCCUPANTS EXISTING COMMON PATH OF TRAVEL = 87' .01.00 S s . ".,0.0. . .. 0... *100 N+ • TENANT: Iosco Fire Protection COSCO FIRE PROTECTION 4308 SOUTH 131ST PLACE TUKWILA, WA 98124 ARCHITECTS WEAVER ARCHITECTS, INC. 1411 FOURTH AVENUE, SUITE 810 SEATTLE, WASHINGTON 98101 P. 206.262.9622 F. 206.262.9507 All reproduction & intellectual property rights reserved c 2016 Professional seal 8109 11‘ TA REGISTERED ARCHITECT AVER OF WASHINGTON No. Issue Description Date REVIEW SET 08.05.16 PERMIT SET 08.11.16 Drawn by: PG Reviewed by: Project No: # 16-141-00 HW EGRESS PLAN Original drawing is 24" x 36". Scale entities accordingly if reduced G.0.2 Permit Agency o.229 CITY OF TUKWILA AUG 11 2016 PERMIT CENTER GROUND FLOOR DEMOLITION PLAN , 0 6' 12' 24' DEMOLITION SYMBOLS _ _ EXISTING CONSTRUCTION TO BE REMOVED F�. 1 EXISTING CONSTRUCTION TO REMAIN EXISTING ARE EXTINGUISHER GENERAL DEMOLITION NOTES 1. REFER TO CONSTRUCTION PLAN AND COUNG PLAN FOR EXTENT OF DEMOU11ON. 2. SAVE AND STORE ALL REMOVED UGHT FIXTURES, EXIT SIGNS, DOORS & HARDWARE FOR RE -USE, UON. 3. REMOVE ALL TELEPHONE, ELECTRICAL, AND DATA OUTLETS, FIXTURES, PANELS, ETC FROM ALL DEMOLISHED PARTITIONS. REMOVE ALL CORRESPONDING CABLES, CONDUIT, WIRING, ETC. ALL THE WAY BACK TO THE ORIGINATING SOURCE, UON. 4. CONFIRM WITH TENANT THE EXTENT OF FLOOR AND WALL FINISHES TO BE REMOVED AND REPLACED. CONFIRM NEW FINISH REQUIREMENTS WITH TENANT. 5. REMOVE ALL ABANDONED SCREWS, NAILS, ANCHORS, ETC. FROM EXISTING PARTITIONS THROUGHOUT SUITE. KEYED SHEET NOTES ODEMO DOOR, FRAME, AND HARDWARE - TO BE STORED OR RELOCATED AND REINSTALLED WHERE APPUCABLE. VERIFY WITH TENANT. 0. REMOVE PORTION OF EXISTING PARTITION. 3OREMOVE EXISTING MOP SINK AND ASSOCIATED PLUMBING FIXTURES, ETC., CAP AND ENCLOSE EXISTING SUPPLY AND WAISTLINES IN ADJACENT CONSTRUCTION FOR POSSIBLE FUTURE USE. 4O REMOVE PARTIAL HEIGHT PARTITION AND PATCH AND REPAIR ADJACENT FINISHES. OREMOVE ALL EXISTING ACOUSTIC COUNG TILES IN THIS LOCATION, SEE REFLECTED CEIUNG PLAN FOR ADDITIONAL INFORMATION. 6O EXISTING CEIUNG TO REMAIN. EXISTING PHONE BOARD TO REMAIN, EXISTING EQUIPMENT AND CABLES TO BE REMOVED. EXISTING DOORS 7O TO REMAIN. G.C. TO COORDINATE WITH THE TENANT FOR ITEMS TO BE REMOVED AND RELOCATED INCLUDING POWER AND DATA OUTLETS AND OTHER ITEMS IN THIS CLOSET. R � ��CE PROVED CODS p O� P� RIG 2 6 70 City DIVISION BOLDING ..*00010 ��.00... OO Fire Protection TENANT: COSCO FIRE PROTECTION 4308 SOUTH 131ST PLACE TUKWILA, WA 98124 ARCHITECTS WEAVER ARCHITECTS, INC. 1411 FOURTH AVENUE, SUITE 810 SEATTLE, WASHINGTON 98101 P. 206.262.9622 F. 206.262.9507 All reproduction & intellectual property rights reserved c 2016 Professional seal REGISTERED ARCHITECT WEAVER TAT OF WASHINGTON No. Issue Description Date REVIEW SET 08.05.16 PERMIT SET 08.11.16 Drawn by: pG Reviewed by: Project No: # 16-141-00 HW DEMOLITION PLAN Original drawing is 24" x 36". Scale entities accordingly if reduced A.1.1 Permit Agency CIT pF OF TUKWILA AUG 11 2016 PERMIT CENTER 1 GROUND FLOOR CONSTRUCTION PLAN ah 0 6' 12' 24' cm M CASEWORK ELEVATION 0 2' 4' 8' n JAMB OF DOOR FOR REFERENCE, CONFIRM DIMENSION IN FIELD 3/8" = 1'-0" 0 01 DOOR TYPE SYMBOL LEGEND c.1 w --STAIN GRADE WOOD FRAME STAIN GRADE SOLID CORE I WIDTH WOOD DOOR co W 6 / / STAIN GRADE WOOD FRAME 1/4" TEMPERED GLASS INSET STAIN GRADE WI SOLID CORE je WOOD DOOR .8 1 EXISTING CONSTRUCTION TO REMAIN NEW INSULATED INTERIOR PARTI11ON CONSTRUCTION, PER DETAIL J/A.9.1 GLASS W/ FRAME Wi�i,13i4 NEW CASEWORK / MILLWORK UNE OF UPPER CABINETS (WHERE OCCURS) F EXISTING FIRE EXTINGUISHER CABINET, UNLESS OTHERWISE NOTED, SEE KEY NOTES GENERAL NOTES DOOR & HARDWARE NOTES 1. SEE HARDWARE SPECIFICATIONS FOR HARDWARE, TYPES AND INSTALLATION. 2. DOOR WIDTH & HEIGHT ARE NOMINAL DIMENSIONS FROM JAMB TO JAMB AND FINISH FLOOR TO BOTTOM OF FRAME 0 HEAD. REFER TO SPECIFICA11ONS FOR CLEARANCES. 3. DOOR CONSTRUCTION SHALL PROVIDE ATTACHMENT OF ALL HARDWARE WITHOUT THROUGH - BOLTS. 4. DOOR / HARDWARE SHALL COMPLY WITH All. APPLICABLE IBC & ACCESSIBILITY REQUIREMENTS. DOOR SCHEDULE � m Z DOOR 4 Z 2 W a. 100 3'-O" 7'-O" B 1 WD NA CONFIRM/MODIFY EXISTING OPENING IN FIELD AS NECESSARY FOR DOOR 102 3'-O" 7-0" A 2 WD NA 103 3'-O" 7'-0" A 2 WD NA 106 3'-0" 7'-0" A 2 WD NA 1. REFER TO PROJECT NOTES FOR CONSTRUCTION REQUIREMENTS. 2. GENERAL CONTRACTOR TO FIELD VERIFY ALL EXISTING CONDITIONS PRIOR TO COMMENCEMENT OF WORK. 3. ALL INTERIOR PARTITION, PENETRATIONS, AND OTHER OPENINGS IN THE BUILDING SHELL SHALL BE SEALED, GASKETED, OR WEATHER STRIPPED AS REQUIRED TO MEET PARTITION RATINGS. 4. WHERE PARTI11ON LAYOUT INTERSECTS EXISTING SHELL/CORE GYPSUM BOARD, REMOVE EXISTING CORNER BEADS AND OTHER ACCESSORIES, AIJGN FACE OF PARTIONS, TAPE & SAND SMOOTH FOR NEW FINISH. 5. PROVIDE PARTITION ANCHOR BRACKETS FOR ALL CASEWORK, FIXTURES, EQUIPMENT, & DEVICES MOUNTED ON OR ATTACHED TO PARTITIONS. 6. ALL WOOD USED IN INTERIOR FRAMING IS TO BE FIRE-RETARDENT TREATED WOOD. 7. PARTITIONS ARE TO BE BUILDING STANDARD FLOOR TO CEILING PARTITIONS, LION. SEE TYPICAL WALL DETAIL SHEET FOR MORE INFORMATION. 8. DOORS AND CASED OPENINGS WITHOUT OR MATCH EXISTING SUITE STANDARD. 9. PATCH EXISTING CONSTRUCTION WHERE FOR NEW PAINT FINISH AS SCHEDULED. DIMENSIONS OR DETAILS ARE TO BE LOCATED 4" FROM ADJACENT WALL DEMOLITION HAS OCCURRED FLUSH WITH ADJACENT SURFACE AND PREP 10. WHERE PENETRATIONS OCCUR IN GWB AS A RESULT OF SCREW/NAILS/ANHOR, ETC. REMOVAL, PATCH FLUSH WITH ADJACENT CONSTRUCTION AND PREP FOR NEW PAINT AS SCHEDULED. 107 3'-O" 7'-0" A 1 WD NA HARDWARE GROUP KEYED SHEET NOTES HARDWARE GROUP HARDWARE NOTES GROUP 1 SINGLE, PASSAGE LATCHSET NON -RATED 1 1/2 PAIR HINGES 1 LEVER STYLE PASSAGE LATCHSET 1 WALL MOUNTED DOOR STOP GROUP 2 SINGLE, OFFICE LOCKSET NON -RATED 1 1/2 PAIR HINGES 1 LEVER STYLE OFFICE LOCKSET 1 WALL MOUNTED DOOR STOP 1,-1" �" =: `i - \ \ i ____ I 1J' 11/1/' \ \ - -_ \ `/ / 'i i i / _ / : i \ \ N) \ \ \--_ \ i o o I amme I I 111111I o o o o o 0 o 0 o 0 ` - I' - - - i o ACINi : — ; ___ ---_ X ---- > V. 0 0 ` 0 CASEWORK ELEVATION 0 2' 4' 8' n JAMB OF DOOR FOR REFERENCE, CONFIRM DIMENSION IN FIELD 3/8" = 1'-0" 0 01 DOOR TYPE SYMBOL LEGEND c.1 w --STAIN GRADE WOOD FRAME STAIN GRADE SOLID CORE I WIDTH WOOD DOOR co W 6 / / STAIN GRADE WOOD FRAME 1/4" TEMPERED GLASS INSET STAIN GRADE WI SOLID CORE je WOOD DOOR .8 1 EXISTING CONSTRUCTION TO REMAIN NEW INSULATED INTERIOR PARTI11ON CONSTRUCTION, PER DETAIL J/A.9.1 GLASS W/ FRAME Wi�i,13i4 NEW CASEWORK / MILLWORK UNE OF UPPER CABINETS (WHERE OCCURS) F EXISTING FIRE EXTINGUISHER CABINET, UNLESS OTHERWISE NOTED, SEE KEY NOTES GENERAL NOTES DOOR & HARDWARE NOTES 1. SEE HARDWARE SPECIFICATIONS FOR HARDWARE, TYPES AND INSTALLATION. 2. DOOR WIDTH & HEIGHT ARE NOMINAL DIMENSIONS FROM JAMB TO JAMB AND FINISH FLOOR TO BOTTOM OF FRAME 0 HEAD. REFER TO SPECIFICA11ONS FOR CLEARANCES. 3. DOOR CONSTRUCTION SHALL PROVIDE ATTACHMENT OF ALL HARDWARE WITHOUT THROUGH - BOLTS. 4. DOOR / HARDWARE SHALL COMPLY WITH All. APPLICABLE IBC & ACCESSIBILITY REQUIREMENTS. DOOR SCHEDULE � m Z DOOR 4 Z 2 W a. 100 3'-O" 7'-O" B 1 WD NA CONFIRM/MODIFY EXISTING OPENING IN FIELD AS NECESSARY FOR DOOR 102 3'-O" 7-0" A 2 WD NA 103 3'-O" 7'-0" A 2 WD NA 106 3'-0" 7'-0" A 2 WD NA 1. REFER TO PROJECT NOTES FOR CONSTRUCTION REQUIREMENTS. 2. GENERAL CONTRACTOR TO FIELD VERIFY ALL EXISTING CONDITIONS PRIOR TO COMMENCEMENT OF WORK. 3. ALL INTERIOR PARTITION, PENETRATIONS, AND OTHER OPENINGS IN THE BUILDING SHELL SHALL BE SEALED, GASKETED, OR WEATHER STRIPPED AS REQUIRED TO MEET PARTITION RATINGS. 4. WHERE PARTI11ON LAYOUT INTERSECTS EXISTING SHELL/CORE GYPSUM BOARD, REMOVE EXISTING CORNER BEADS AND OTHER ACCESSORIES, AIJGN FACE OF PARTIONS, TAPE & SAND SMOOTH FOR NEW FINISH. 5. PROVIDE PARTITION ANCHOR BRACKETS FOR ALL CASEWORK, FIXTURES, EQUIPMENT, & DEVICES MOUNTED ON OR ATTACHED TO PARTITIONS. 6. ALL WOOD USED IN INTERIOR FRAMING IS TO BE FIRE-RETARDENT TREATED WOOD. 7. PARTITIONS ARE TO BE BUILDING STANDARD FLOOR TO CEILING PARTITIONS, LION. SEE TYPICAL WALL DETAIL SHEET FOR MORE INFORMATION. 8. DOORS AND CASED OPENINGS WITHOUT OR MATCH EXISTING SUITE STANDARD. 9. PATCH EXISTING CONSTRUCTION WHERE FOR NEW PAINT FINISH AS SCHEDULED. DIMENSIONS OR DETAILS ARE TO BE LOCATED 4" FROM ADJACENT WALL DEMOLITION HAS OCCURRED FLUSH WITH ADJACENT SURFACE AND PREP 10. WHERE PENETRATIONS OCCUR IN GWB AS A RESULT OF SCREW/NAILS/ANHOR, ETC. REMOVAL, PATCH FLUSH WITH ADJACENT CONSTRUCTION AND PREP FOR NEW PAINT AS SCHEDULED. 107 3'-O" 7'-0" A 1 WD NA HARDWARE GROUP KEYED SHEET NOTES HARDWARE GROUP HARDWARE NOTES GROUP 1 SINGLE, PASSAGE LATCHSET NON -RATED 1 1/2 PAIR HINGES 1 LEVER STYLE PASSAGE LATCHSET 1 WALL MOUNTED DOOR STOP GROUP 2 SINGLE, OFFICE LOCKSET NON -RATED 1 1/2 PAIR HINGES 1 LEVER STYLE OFFICE LOCKSET 1 WALL MOUNTED DOOR STOP 1,-1" CABINET DOOR ON CONCEALED HINGES, P -LAM KNISH BOTH SIDES MELAMINE CABINET INTERIOR ADJ. SHELVES W/ MELAMINE FINISH, SEE ELEVATION FOR QUANTITY 4" WIRE PULL MILLWORK SECTION — UPPER CABINET REPAIR EXISTING SKYLIGHT LEAK IN THIS LOCATION BEFORE INSTALLING NEW CEILING TILES AND FINISHES. CONFIRM ISSUES WITH TENANT AND BUILDING OWNER. OPROVIDE NEW DOOR AT EXISTING OPENING IN EXISTING PARTI11ON. SEE DOOR SCHEDULE FOR ADDITIONAL INFORMATION. 3O NEW WATER HEATER TO BE LOCATED AT THE LOCATION INDICATED. CONFIRM REQUIREMENTS WITH TENANT. PROVIDE NEW CARD READER AT EXISTING EXTERIOR DOOR. CONFIRM REQUIREMENTS IN FIELD WITH EXISTING CONDITIONS AND TENANT'S REQUIREMENTS AND MAKE MODIFICATIONS NECESSARY. EACH DOOR SHALL BE READILY OPENABLE FROM THE EGRESS SIDE WITHOUT THE USE OF A KEY OR SPECIAL KNOWLEDGE OR EFFORT PER IBC SECTION 1010.1.9. NEW PARTITION TO BE JUST SHORT OF TOP OF EXISTING GYPSUM BOARD CEILING AT THIS LOCATION TO ALLOW FOR AIR MOVEMENT AT EXISTING EXHAUST FAN TO REMAIN. CONFIRM HEIGHT WITH TENANT AND MECHANICAL SUB -CONTRACTOR SELECTED BY THE G.C. TOP OF PARTITION TO BE ±12'-0" A.F.F. CONFIRM FINAL HEIGHT IN FIELD WITH TENANT. BRACE TOP OF O THIS PORTION OF PARTITION TO EXISTING TILT -UP CONCRETE PANEL AND MEZZANINE STRUCTURE WITH TYPICAL BRACING PER PARTITION DETAILS. 7ONEW 1/4" TEMPERED GLASS RELIGHT IN BUILDING STANDARD WOOD FRAME (MATCH EXISTING ADJACENT SILL AND HEAD HEIGHTS, WOOD PROFILES AND FINISH). 8O PROVIDE NEW CARPET AND RUBBER BASE IN THIS ROOM. CONFIRM FINISH SELECTIONS WITH TENANT. ONEW PROJECTOR SCREEN TO BE INSTALLED AT THIS WALL CONFIRM REQUIREMENTS FOR INSTALLATION W/ TENANT'S PROVIDED SCREEN. 10 NEW WALL MOUNTED SINK AND FAUCET. CONFIRM MODELS AND SPECIFICATIONS WITH TENANT. SEE ELEVATIONS 2'-1" 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 REVIED FOR CODE COM V DE AppRO ...00.. O►O ".00111** 4• ® * a Fire Protection TENANT: COSCO FIRE PROTECTION 4308 SOUTH 131ST PLACE TUKWILA, WA 98124 ARCHITECTS WEAVER ARCHITECTS, INC. 1411 FOURTH AVENUE, SUITE 810 SEATTLE, WASHINGTON 98101 P. 206.262.9622 F. 206.262.9507 All reproduction & intellectual property rights reserved c 2016 Professional seal 109 REGISTERED ARCHITECT . WEAVER A OF WASHINGTON No. Issue Description Date REVIEW SET 08.05.16 PROVIDE BACK INDICATED ON ELEV SCRIBE TO WALL ATi 2 C 2,16 city 0§ 1-0N.Iia DING DIVISION PERMIT SET 08.11.16 COUNTERTOP FINISH PER KNISH SCHEDULE DRAWER W/ MELAMINE FINISH ON FULL EXTENSION SLIDES ADJ. SHELF W/ MELAMINE FINISH MELAMINE CABINET INTERIOR CABINET DOOR ON CONCEALED HINGES, P -LAM FINISH BOTH SIDES BASE AS SCHEDULED FINISH FLOOR MILLWORK SECTION — BASE CABINET O[_ LJ6 12" 124" Drawn by: PG Reviewed by: Project No:# 16-141-00 HW CONSTRUCTION PLAN/ DOOR SCHEDULE/ HARDWARE SCHEDULE/ DOOR TYPES Original drawing is 24" x 36". Scale entities accordingly if reduced A.2A.1 Permit Agency D I RECEIVED CITY OF TUKWILA AUG 11 2016 PERMIT CENTER ‘fse 02.141 1 o o o o o o o 0 o 0 o 0 , I' - , - 1' o o . 0 o 0 0 ` 0 0 • 0 0 O O O O O 0 0 0 0 0 0 0 ` 0 O CABINET DOOR ON CONCEALED HINGES, P -LAM KNISH BOTH SIDES MELAMINE CABINET INTERIOR ADJ. SHELVES W/ MELAMINE FINISH, SEE ELEVATION FOR QUANTITY 4" WIRE PULL MILLWORK SECTION — UPPER CABINET REPAIR EXISTING SKYLIGHT LEAK IN THIS LOCATION BEFORE INSTALLING NEW CEILING TILES AND FINISHES. CONFIRM ISSUES WITH TENANT AND BUILDING OWNER. OPROVIDE NEW DOOR AT EXISTING OPENING IN EXISTING PARTI11ON. SEE DOOR SCHEDULE FOR ADDITIONAL INFORMATION. 3O NEW WATER HEATER TO BE LOCATED AT THE LOCATION INDICATED. CONFIRM REQUIREMENTS WITH TENANT. PROVIDE NEW CARD READER AT EXISTING EXTERIOR DOOR. CONFIRM REQUIREMENTS IN FIELD WITH EXISTING CONDITIONS AND TENANT'S REQUIREMENTS AND MAKE MODIFICATIONS NECESSARY. EACH DOOR SHALL BE READILY OPENABLE FROM THE EGRESS SIDE WITHOUT THE USE OF A KEY OR SPECIAL KNOWLEDGE OR EFFORT PER IBC SECTION 1010.1.9. NEW PARTITION TO BE JUST SHORT OF TOP OF EXISTING GYPSUM BOARD CEILING AT THIS LOCATION TO ALLOW FOR AIR MOVEMENT AT EXISTING EXHAUST FAN TO REMAIN. CONFIRM HEIGHT WITH TENANT AND MECHANICAL SUB -CONTRACTOR SELECTED BY THE G.C. TOP OF PARTITION TO BE ±12'-0" A.F.F. CONFIRM FINAL HEIGHT IN FIELD WITH TENANT. BRACE TOP OF O THIS PORTION OF PARTITION TO EXISTING TILT -UP CONCRETE PANEL AND MEZZANINE STRUCTURE WITH TYPICAL BRACING PER PARTITION DETAILS. 7ONEW 1/4" TEMPERED GLASS RELIGHT IN BUILDING STANDARD WOOD FRAME (MATCH EXISTING ADJACENT SILL AND HEAD HEIGHTS, WOOD PROFILES AND FINISH). 8O PROVIDE NEW CARPET AND RUBBER BASE IN THIS ROOM. CONFIRM FINISH SELECTIONS WITH TENANT. ONEW PROJECTOR SCREEN TO BE INSTALLED AT THIS WALL CONFIRM REQUIREMENTS FOR INSTALLATION W/ TENANT'S PROVIDED SCREEN. 10 NEW WALL MOUNTED SINK AND FAUCET. CONFIRM MODELS AND SPECIFICATIONS WITH TENANT. SEE ELEVATIONS 2'-1" 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 REVIED FOR CODE COM V DE AppRO ...00.. O►O ".00111** 4• ® * a Fire Protection TENANT: COSCO FIRE PROTECTION 4308 SOUTH 131ST PLACE TUKWILA, WA 98124 ARCHITECTS WEAVER ARCHITECTS, INC. 1411 FOURTH AVENUE, SUITE 810 SEATTLE, WASHINGTON 98101 P. 206.262.9622 F. 206.262.9507 All reproduction & intellectual property rights reserved c 2016 Professional seal 109 REGISTERED ARCHITECT . WEAVER A OF WASHINGTON No. Issue Description Date REVIEW SET 08.05.16 PROVIDE BACK INDICATED ON ELEV SCRIBE TO WALL ATi 2 C 2,16 city 0§ 1-0N.Iia DING DIVISION PERMIT SET 08.11.16 COUNTERTOP FINISH PER KNISH SCHEDULE DRAWER W/ MELAMINE FINISH ON FULL EXTENSION SLIDES ADJ. SHELF W/ MELAMINE FINISH MELAMINE CABINET INTERIOR CABINET DOOR ON CONCEALED HINGES, P -LAM FINISH BOTH SIDES BASE AS SCHEDULED FINISH FLOOR MILLWORK SECTION — BASE CABINET O[_ LJ6 12" 124" Drawn by: PG Reviewed by: Project No:# 16-141-00 HW CONSTRUCTION PLAN/ DOOR SCHEDULE/ HARDWARE SCHEDULE/ DOOR TYPES Original drawing is 24" x 36". Scale entities accordingly if reduced A.2A.1 Permit Agency D I RECEIVED CITY OF TUKWILA AUG 11 2016 PERMIT CENTER ‘fse 02.141 0 CLOSET 109 ®� • II`I ■ mME T !RU_ a 11 _ PP ■■ MEM ME -1 • MEM •©■1■1UI 0 ►/ ■1E conal=111111 MEI • r.• 0 REFLECTED CEILING PLAN r L 6i 1 12' 24' 1/8" = 1'-O"66,1) 03 *1111 MEE 0 0 OFFICE 109 emmummum mimes 11111101 ►11 E NMI ���11111 11` 1IL �� 1 ea REC:1111111 tJ■111Num mom 1111//A1//■ ■•111■111MI EMI imisi sm 10. _El CEILING LEGEND — LIGHTING SYMBOL DESCRIPTION/SPEC L1 EXISTING 2' X 4' FLUORESCENT FIXTURE TO REMAIN 0 NEW RECESSED LED CAN LIGHT, 10 WATT MAX, MATCHED ADJACENT FIXTURE COLOR TEMPERATURES OR CONFIRM WITH TENANT. EXISTING 2' X 4' FLUORESCENT FIXTURE TO BE REMOVED. EXISTING SURFACE MOUNTED FLUORESCENT FIXTURE TO BE REMOVED. EXISTING 2' X 2' FLUORESCENT FIXTURE W/ (2) 40 WATT LAMPS. EXISTING SPRINKLER FOR REFERENCE ONLY, NOT FOR DESIGN INTENT. NEW GYPSUM BOARD CEILING, SEE A9.1 FOR DETAILS EXISTING SPEAKER FOR REFERENCE ONLY, NOT FOR DESIGN INTENT. NEW 2' X 4' INDIRECT/DIRECT LED FIXTURE W/ 44 WATT MAX. ADJACENT FIXTURE COLOR TEMPERATURES OR CONFIRM WITH TENANT. EXISTING CEILING MOUNTED ALARM FOR REFERENCE ONLY, NOT FOR DESIGN INTENT. EXISTING HVAC FOR REFERENCE ONLY, NOT FOR DESIGN INTENT. EXISTING EXIT SIGN TO REMAIN. COORDINATE WITH CODE OFFICIAL EXISTING SURFACE MOUNTED FLUORESCENT FIXTURE W/ (2) 4' FLUORESCENT LAMPS NEW EXIT SIGN. EXISTING RECESSED CAN UGHT TO REMAIN. O EXISTING SURFACE MOUNTED INCANDESCENT FIXTURE NEW SURFACE MOUNTED EGRESS PATH UGHTING EXISTING SURFACE MOUNTED INCANDESCENT VANITY FIXTURE es EXISTING SURFACE MOUNTED WALL WASH UGHT FIXTURE TO REMAIN KEYED SHEET NOTES O LIGHT FIXTURES TO PROVIDE EMERGENCY LIGHTING TO ALLOW FOR UGHT LEVEL COMPLYING WITH IBC SECTION 1006.4. SEE G.0.2 FOR ADDITIONAL INFORMATION. PROVIDE NEW BATTERY BACK-UP OR NEW FIXTURE IF REQUIRED. REPLACE EXISTING CEIUNG TILE IN THIS ROOM. REVISE EXISTING HVAC AT THIS LOCATION TO ACCOMMODATE NEW LIGHT FIXTURE OR CONFIRM LOCATION OF FIXTURE WITH TENANT IN FIELD. MECHANICAL DESIGN BY OTHERS UNDER SEPARATE PERMIT. EXISTING GYPSUM BOARD CEILING TO REMAIN. EXISTING SKYLIGHT ABOVE. NEW PARTITION TO BE JUST SHORT OF TOP OF EXISTING GYPSUM BOARD CEILING AT THIS LOCATION TO ALLOW FOR AIR MOVEMENT AT EXISTING EXHAUST FAN TO REMAIN. CONFIRM HEIGHT WITH TENANT AND MECHANICAL SUB -CONTRACTOR SELECTED BY THE G.C. VIEWED FOR ..ODE COMP`, D CE CODE 02,62016 } city of `dAa pi SIGN BUILDING bRrO TENANT: COSCO Fire. Protection COSCO FIRE PROTECTION 4308 SOUTH 131ST PLACE TUKWILA, WA 98124 ARCHITECTS WEAVER ARCHITECTS, INC. 1411 FOURTH AVENUE, SUITE 810 SEATTLE, WASHINGTON 98101 P. 206.262.9622 F. 206.262.9507 All reproduction & intellectual property rights reserved c 2016 Professional seal 810 REGISTERED ARCHITECT WEAVER STATE OF WASHINGTON No. Issue Description I1 Date REVIEW SET 08.05.16 PERMIT SET 08.11.16 Drawn by: pG Reviewed by: Project No: # 16-141-00 HW REFLECTED CEILING PLAN Original drawing is 24° x 36". Scale entities accordingly if reduced A.2B.1 Permit Agency Z29 CITY OF TUKWILA AUG 11 2016 PERMIT CENTER CORNER REINFORCEMENT, TYP. ACOUSTIC INSULATION METAL STUDS 5/8* GYP. BOARD TYP. PARTITION INTERSECTION FRAMING BOTTOM OF EXISTING WOOD STRUCTURE OR NEW BLOCKING 1 PROVIDE ENCAPSULATED ACOUSTICAL BATT EXTENDING 24" EACH SIDE OF PARTITION. l NTS 12" LEG AT STRUCTURE — ATTACH W/ (2) FASTENERS PER BRACE 2 1/2"x25 GA MIN. METAL STUD BRACING 0 48* OC TO STRUCTURE EXISTING SUSPENDED CEUNG MATCH BUILDING STANDARD HEAD CONDITION GRID SPACER BLACK METAL TOP TRACK ATTACHED TO BRACING W/2 SELF—TAPPING SM. SCREWS 48"oc, AND 3/4" PIPE SLEEVES ACOUSTIC BATT INSULATION INSULATION 3-5/8" X 20 GA METAL STUDS 0 24" oc. 1 LAYER 5/8* TYPE "X' GYP. BD. EA. SIDE OF METAL STUDS INSULATION POWER DRNEN FASTENER 0 24" O.C. CONCRETE SLAB, LAG SCREWS 0 16" 0.C. 0 WOOD SHEATHING MET RUNNER TRACK SEALANT PARTIAL HEIGHT PARTITION r • METAL STUDS AS SCHEDULED 25 GA. RUNNER WHERE OPENING EXCEEDS 4'-6" BOTTOM OF SCHEDULED CEILING UP TO 4'-6" MAX: RUNNER TRACK UP TO 8'-0 MAX: DOUBLE 25 GA STUD HEADER & RUNNER TRACK 3'-0"to 4'-6"MAX: DOUBLE STUDS 4'-1"to 8'-0"MAX: DOUBLE 25 GA MTL STUDS DOOR FRAME TOP OF SLAB ------ BOTTOM RUNNER 12 x 25 GA. ANCHOR ANGLE 0 25 GA. STUDS TYP. FRAMING C0 DOOR OPENING NTS NOTE COORDINATE ANCHOR 3 STUDS BRACKET LOCATIONS W/ MIN. CASEWORK & EQUIPMDff WHERE SCHEDULED, AND MANUF. MOUNTING INSTRUCTIONS 1/2" STANDARD BLOCKING DETAIL MAIN RUNNER BOTTOM OF FINISHED CEILING ANCHOR BRACKET: 6"X16ga UNPUNCHED STUD TRACK, ATTACH TO 3 STUDS MIN FINISHED FLOOR NTS UNDERSIDE OF STRUCTURE ANCHOR TO STRUCTURE USE 3/16"0 POWER DRIVEN STUD AT METAL DECK OR W/ 3/4" LAG BOLTS AT WOOD DECK 2 1/2"X16 GA. TRACK WITH L/R RATIO OF LESS THAN 200 MAX. ATTACH STRUT TO MAIN RUNNER WITH 1/4" MACHINE BOLT GYPSUM BOARD CEILING SEISMIC COMPRESSION STRUT 6 11' 8" MAX. 8 GA. HANGER WIRES AT 4'-0" O.C. SADDLED—TIED AROUND MAIN RUNNERS 1 1/2"X1 1 /2" CONT. ANGLE #12 DIAGONAL WIRE TIES 0 12'-0" O.C. EACH WAY 1 1/2"X16 GA. HOT ROLLED MAIN RUNNER CHANNELS AT 4'-0" O.C.-1.12#/FT MIN. 5/8" GYP. B0. SADDLE—TIED CROSS FURRING TO MAIN RUNNERS WITH 2 STRANDS OF 18 GA. WIRE OR 1 STRAND OF 16 GA. WIRE 7/8"X26 GA. CROSS FURRING CHANNELS AT 16" O.C. PARTITION AS SCHEDULED GYP BD CLG SEISMIC RESTRAINED END 0 6" 11' 0 • • NOTES; PROVIDE MIN 25 GA STUDS & ANCHOR BRACKET ANCHORAGES. DOUBLE STUDS END OF PARTITIONS. 3-18 PAN HEAD SHT. MTL SCREWS 6"x16 GA UNPUNCHED STUD TRACK WITH FLANGES COPED AT VERTICAL STUDS. ATTACH TO TWO STUDS MIN. & EXTEND 6"MIN BEYOND MOUNTING POINT EACH DIRECTION. 1. TYPICAL ANCHOR BRACKET ASSEMBLY FOR HANDRAILS, GRAB BARS & TOILET ACCESSORY ANCHORAGES. 2. COORDINATE ANCHOR BRACKET LOCATION WITH ACCESSORY MANUFACURER MOUNTING INSTRUCTIONS. STANDARD BLOCKING DETAIL DEVICES SHOWN STACKED IN PLAN ARE TO ALIGN VERT. AS SHOWN BELOW • " 1 to :t 1 r i " N • • th AT LOCATION AS DIMENSIONED ON PLAN; OR NEXT TO DOOR / OPENING AS DIMENSIONED BELOW 00 FIRE ALARM STROBE FRAME WHERE OCCURS ROOM SIGNAGE, ETC. THERMOSTAT LIGHT SWITCHES, WALL MOUNTED OCCUPANCY SENSOR CARD READER WHERE OCCURS HARDWARE LATCH FINISHED FLOOR 1 TELEPHONE OUTLET ELECTRICAL OUTLET 1. LOCATED SWITCHPLATES, ELECTRICAL AND TELEPHONE WALL OUTLETS AT NEAREST STUD FROM SCALED LOCATION ON PLAN, UNLESS SPECIFICALLY DIMENSIONED ON PLAN, ELEVATION, OR LOCATION AS PER DIAGRAM ABOVE. 2. CENTER FIRE ALARM STROBES DIRECTLY ABOVE FIRE EXTINGUISHER CABINETS WHERE BOTH OCCUR. CHD DEVICE MOUNTING HEIGHTS NTS REVIEWED FOR CODE COMP I CE APPROVED AUG26 2016 City of Tukwila BUILDING DIVISION N.T.S. 8 GA. HANGER WIRES 4'-0" O.C., SADDLE—TIED AROUND MAIN RUNNERS SADDLE—TIED CROSS FURRING TO MAIN RUNNERS WITH 2 STRANDS OF 18 GA. WIRE OR 1 STRAND OF 16 GA. WIRE COMPRESSION STRUT 1 1/2"x16 GA HOT ROLLED MAIN RUNNER CHANNELS 0 4'-0" O.C. 1.121/FT MIN. 7/8"x26 GA. CROSS FURRING CHANNELS 016" O.C. GYPSUM BOARD GYPSUM BOARD CEILING FRAMING M I� 0 u l� 1'-0" 2'_O" 13'-0" 445131 4.DWG .6000 ."s+O 0 Ai. *,0 TENANT: COSCO Fire Protection COSCO FIRE PROTECTION 4308 SOUTH 131ST PLACE TUKWILA, WA 98124 ARCHITECTS WEAVER ARCHITECTS, INC. 1411 FOURTH AVENUE, SUITE 810 SEATTLE, WASHINGTON 98101 P. 206.262.9622 F. 206.262.9507 All reproduction & intellectual property rights reserved c 2016 Professi • nal seal 109 REGISTERED ARCHITECT A. WEAVER TATE OF WASHINGTON No. Issue Description Date REVIEW SET 08.05.16 PERMIT SET 08.11.16 Drawn by: PG Reviewed by: Project No: # 16-141-00 HW PARTITION TYPES / FRAMING DETAILS / CEILING DETAILS Original drawing is 24" x 36". Scale entities accordingly if reduced A.9.1 Permit Agency RECEIVED CITY OF TUKWILA AUG 11 2016 PERMIT CENTER bit 6- ostig