Loading...
HomeMy WebLinkAboutPermit D16-0231 - 16400 BUILDING SUITE 406 - TENANT IMPROVEMENTSPECULATIVE SUITE 16400 SOUTHCENTER PKWY SUITE 406 D16-0231 Parcel No: Address: City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-438-9350 Web site: http://www.TukwilaWA.gov DEVELOPMENT PERMIT 2623049021 16400 SOUTHCENTER PKWY Project Name: SPECULATIVE SUITE Permit Number: D16-0231 Issue Date: 8/31/2016 Permit Expires On: 2/27/2017 Owner: Name: Address: Contact Person: Name: Address: Contractor: Name: Address: License No: Lender: Name: Address: RADOVICH PROPERTIES LLC 2835 82ND AVE SE STE S 1, MERCER ISLAND, WA, 98040 LINDA DUCEY 1500 WESTLAKE AVE N, SUITE 1, SEATTLE, WA, 98109 Phone: (206) 441-1449 D P INC GENERAL CONTRACTORS Phone: (206) 361-2989 19936 BALLINGER WAY NE , LAKE FOREST PARK, WA, 98155 DPINCGC066BU Expiration Date: 1/31/2018 DESCRIPTION OF WORK: INTERIOR TENANT IMPROVEMENTS TO ANE XISTING OFFICE SUITE ONT EH FOURTH FLOOR, SUITE #406, FOR OFFICE USE TO INCLUDE DEMOLITION OF DOORS, RELITES, AND PATITIONS, NEW CONSTRUCTION OF PARTITION, NEW DOORS AND RELITES, EXISTING LIGHTING RELOCATED. NO STRUCTURAL WORK AND NO ALTERATIONS TO THE BUILDING CORE. Project Valuation: $73,500.00 Type of Fire Protection: Sprinklers: YES Fire Alarm: Type of Construction: IIA Electrical Service Provided by: TUKWILA Fees Collected: $2,108.50 Occupancy per IBC: B Water District: TUKWILA Sewer District: TUKWILA Current Codes adopted by the City of Tukwila: International Building Code Edition: International Residential Code Edition: International Mechanical Code Edition: Uniform Plumbing Code Edition: International Fuel Gas Code: 2015 2015 2015 2015 2015 National Electrical Code: WA Cities Electrical Code: WAC 296-46B: WA State Energy Code: 2014 2014 2014 2015 Public Works Activities: Channelization/Striping: Curb Cut/Access/Sidewalk: Fire Loop Hydrant: Flood Control Zone: Hauling/Oversize Load: Land Altering: Landscape Irrigation: Sanitary Side Sewer: Sewer Main Extension: Storm Drainage: Street Use: Water Main Extension: Water Meter: Volumes: Cut: 0 Fill: 0 Number: 0 No Permit Center Authorized Signature: v! Date: U `51—Ko I hearby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction •.r the performance of work. I am authorized to sign and obtain this development p it and agree t he con.. itions attached to this permit. Signature. 14 /1/ / Date: Print Name 0..61/' _ 11 This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: ***BUILDING PERMIT CONDITIONS*** 2: Work shall be installed in accordance with the approved construction documents, and any changes made during construction that are not in accordance with the approved construction documents shall be resubmitted for approval. 3: All permits, inspection record card and approved construction documents shall be kept at the site of work and shall be open to inspection by the Building Inspector until final inspection approval is granted. 4: New suspended ceiling grid and light fixture installations shall meet the seismic design requirements for nonstructural components. ASCE 7, Chapter 13. 5: Partition walls shall not be tied to a suspended ceiling grid. All partitions greater than 6 feet in height shall be laterially braced to the building structure. Such bracing shall be independent of any ceiling splay bracing. 6: All construction shall be done in conformance with the Washington State Building Code and the Washington State Energy Code. 7: There shall be no occupancy of a building until final inspection has been completed and approved by Tukwila building inspector. No exception. 8: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of this requirement. 9: Every occupied space other than enclosed parking garages and buildings used for repair of automobiles shall be ventilated in accordance with the applicable provisions of the International Mechanical Code. 10: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206-431-3670). 11: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center. 12: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 13: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431-3670). 17: The total number of fire extinguishers required for a light hazard occupancy with Class A fire hazards is calculated at one extinguisher for each 3,000 sq. ft. of area. The extinguisher(s) should be of the "all purpose" (2A, 10 B:C) dry chemical type. The travel distance to any extinguisher must be 75' or less. (IFC 906.3) (NFPA 10, 5.4) 14: Portable fire extinguishers, not housed in cabinets, shall be installed on the hangers or brackets supplied. Hangers or brackets shall be securely anchored to the mounting surface in accordance with the manufacturer's installation instructions. Portable fire extinguishers having a gross weight not exceeding 40 pounds (18 kg) shall be installed so that its top is not more than 5 feet (1524 mm) above the floor. Hand- held portable fire extinguishers having a gross weight exceeding 40 pounds (18 kg) shall be installed so that its top is not more than 3.5 feet (1067 mm) above the floor. The clearance between the floor and the bottom of the installed hand-held extinguishers shall not be less than 4 inches (102 mm). (IFC 906.7 and IFC 906.9) 15: Extinguishers shall be located in conspicuous locations where they will be readily accessible and immediately available for use. These locations shall be along normal paths of travel, unless the fire code official determines that the hazard posed indicates the need for placement away from normal paths of travel. (IFC 906.5) 16: Fire extinguishers require monthly and yearly inspections. They must have a tag or label securely attached that indicates the month and year that the inspection was performed and shall identify the company or person performing the service. Every six years stored pressure extinguishers shall be emptied and subjected to the applicable recharge procedures. If the required monthly and yearly inspections of the fire extinguisher(s) are not accomplished or the inspection tag is not completed, a reputable fire extinguisher service company will be required to conduct these required surveys. (NFPA 10, 7.2, 7.3) 18: Egress doors shall be readily openable from the egress side without the use of a key or special knowledge or effort. (IFC 1008.1.8.3 subsection 2.2) 19: Dead bolts are not allowed on auxiliary exit doors unless the dead bolt is automatically retracted when the door handle is engaged from inside the tenant space. (IFC Chapter 10) 20: Exit hardware and marking shall meet the requirements of the International Fire Code. (IFC Chapter 10) 21: Door handles, pulls, latches, locks and other operating devices on doors required to be accessible by Chapter 11 of the International Building Code shall not require tight grasping, tight pinching or twisting of the wrist to operate. (IFC 1008.1.9.1) 22: Exits and exit access doors shall be marked by an approved exit sign readily visible from any direction of egress travel. Access to exits shall be marked by readily visible exit signs in cases where the exit or the path of egress travel is not immediately visible to the occupants. Exit sign placement shall be such that no point in an exit access corridor is more than 100 feet (30,480 mm) or the listed viewing distance for the sign, whichever is less, from the nearest visible exit sign. (IFC 1011.1) 23: Every exit sign and directional exit sign shall have plainly legible letters not less than 6 inches (152 mm) high with the principal strokes of the letters not less than 0.75 inch (19.1 mm) wide. The word "EXIT" shall have letters having a width not less than 2 inches (51 mm) wide except the letter "I", and the minimum spacing between letters shall not be less than 0.375 inch (9.5 mm). Signs larger than the minimum established in section 1011.5.1 of the International Fire Code shall have letter widths, strokes and spacing in proportion to their height. The word "EXIT" shall be in high contrast with the background and shall be clearly discernible when the exit sign illumination means is or is not energized. If an arrow is provided as part of the exit sign, the construction shall be such that the arrow direction cannot be readily changed. (IFC 1011.6) 24: Aisles and aisle access ways serving as a portion of the exit access in the means of egress system shall comply with the requirements of this section. Aisles or aisle access ways shall be provided from all occupied portions of the exit access which contain seats, tables, furnishings, displays and similar fixtures or equipment. The required width of aisles shall be unobstructed. (IFC 1017.1) 25: Exit signs shall be illuminated at all times. To ensure continued illumination for a duration of not less than 90 minutes in case of primary power loss, the sign illumination means shall be connected to an emergency power system provided from storage batteries, unit equipment or on-site generator. (IFC 1011.6.3) 26: Emergency lighting facilities shall be arranged to provide initial illumination that is at least an average of 1 foot-candle (11 lux) and a minimum at any point of 0.1 foot-candle (1 lux) measured along the path of egress at floor level. Illumination levels shall be permitted to decline to 0.6 foot-candle (6 lux) average and a minimum at any point of 0.06 foot-candle (0.6 lux) at the end of the emergency lighting time duration. A maximum -to -minimum illumination uniformity ratio of 40 to 1 shall not be exceeded. (IFC 1006.3.1) 30: Fire protection systems shall be maintained in accordance with the original installation standards for that system. Required systems shall be extended, altered or augmented as necessary to maintain and continue protection whenever the building is altered, remodeled or added to. Alterations to fire protection systems shall be done in accordance with applicable standards. (IFC 901.4) 28: Sprinklers shall be installed under fixed obstructions over 4 feet (1.2 m) wide. (NFPA 13-8.6.5.3.3) 27: All new sprinkler systems and all modifications to existing sprinkler systems shall have fire department review and approval of drawings prior to installation or modification. New sprinkler systems and all modifications to sprinkler systems involving more than 50 heads shall have the written approval of Factory Mutual or any fire protection engineer licensed by the State of Washington and approved by the Fire Marshal prior to submittal to the Tukwila Fire Prevention Bureau. No sprinkler work shall commence without approved drawings. (City Ordinance No. 2436). 31: A fire alarm system is required for this project. The fire alarm system shall meet the requirements of N.F.P.A. 72 and City Ordinance #2437. 33: Maintain fire alarm system audible/visual notification. Addition/relocation of walls or partitions may require relocation and/or addition of audible/visual notification devices. (City Ordinance #2437) 32: All new fire alarm systems or modifications to existing systems shall have the written approval of The Tukwila Fire Prevention Bureau. No work shall commence until a fire department permit has been obtained. (City Ordinance #2437) (IFC 901.2) 34: An electrical permit from the City of Tukwila Building Department Permit Center (206-431-3670) is required for this project. 35: All electrical work and equipment shall conform strictly to the standards of the National Electrical Code. (NFPA 70) 36: The maximum flame spread class of finish materials used on interior walls and ceilings shall not exceed that set forth in Table No. 803.9 of the International Building Code. 37: In order to provide you with the fastest police and fire protection under emergency conditions, please post your suite, room or apartment number in a conspicuous place near the main entry door. 29: Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (City Ordinances #2436 and #2437) 38: Any overlooked hazardous condition and/or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. 39: These plans were reviewed by Inspector 511. If you have any questions, please call Tukwila Fire Prevention Bureau at (206)575-4407. PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 1700 BUILDING FINAL** 1400 FIRE FINAL 0409 FRAMING 0606 GLAZING 0406 SUSPENDED CEILING CITY OF TUKH I Community Development Department Public Works Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.TukwilaWA.gov Building Peril... No. Dt (^ O2-51 Project No. Date Application Accepted: Date Application Expires: (For office use only) CONSTRUCTION PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **Please Print** SITE LOCATION King Co Assessor's Tax No.: 262304-9021 Site Address: 16400 Southcenter Parkway Tenant Name: Speculative Suite Suite Number: 406 PROPERTY OWNER Name: John C. Radovich Development Co. Address: 2385 82nd Ave. SE, suite 300 City: Mercer Island State: WA Zip: 98040 CONTACT PERSON — person receiving all project communication Name: Linda Ducey Address: 1500 Westlake Ave. N. , suite one City: Seattle State: WA Zip: 98109 Phone: (206) 441-1449 Fax: Email: 1.ducey@marvinstein.com GENERAL CONTRACTOR INFORMATION Company Name: DP Inc - General Contrators Address: 19936 Ballinger Way NE City: Shoreline State: WA Zip: 98155 Phone: (206) 361-2989 Fax: Contr Reg No.: DPINCGC066BU Exp Date: 01/31/2018 Tukwila Business License No.: BUS -0994280 H:Wpplications\Forms-Applications On Line'201 I Applications\Permit Application Revised - 8-9-I 1.docx Revised: August 2011 bh New Tenant: Floor: ® Yes ..No 4th floor ARCHITECT OF RECORD Company Name: Marvin Stein Associates Architect Name: Mark Evans Address: 1500 Westlake Ave. N. , suite one City: Seattle State: WA Zip: 98109 Phone: (206) 441-1449 Fax: Email: m.evans@marvinstein.com ENGINEER OF RECORD Name: Address: Company Name: Engineer Name: Address: City: State: Zip: Phone: Fax: Email: LENDER/BOND ISSUED (required for projects $5,000 or greater per RCW 19.27.095) Name: Address: City: State: Zip: Page 1 of 4 BUILDING PERMIT INFORMATIOP 06-431-3670 Valuation of Project (contractor's bid price): $ $151 q(AJ Existing Building Valuation: $ Describe the scope of work (please provide detailed information): Interior tenant improvements to any existing office suite on the fourth floor, suite #406, for office use to include demolition of doors, relites, and partitions, new construction of partition, new doors and relites, existing lighting relocated. No structural work and no alterations to the building core. Will there be new rack storage? ❑ Yes ®.. No If yes, a separate permit and plan submittal will be required. Provide All Building Areas in Square Footage Below PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): 84,975 Floor area of principal dwelling: 64,725 Floor area of accessory dwelling: 0 *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact: Handicap: Will there be a change in use? 0 Yes J No If "yes", explain: FIRE PROTECTION/HAZARDOUS MATERIALS: Sprinklers 0 Automatic Fire Alarm 0 None 0 Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? 0 Yes 0 No If `yes', attach list of materials and storage locations on a separate 8-1/2"x 11 "paper including quantities and Material Safety Data Sheets. SEPTIC SYSTEM 0 On-site Septic System — For on-site septic system, provide 2 copies of a current septic design approved by King County Health Department. H:\Applications\Forms-Applications On Line\2011 Applications\Permit Application Revised - 8-9-I I.docx Revised: August 2011 bh Page 2 of 4 Existing Interior Remodel Addition to Existing Structure New Type of Construction per IBC Type of Occupancy per IBC 1' Floor 0 2° Floor 0 3'd Floor 0 Floors 4 thru 13,700 1,470 0 0 II -A sprinkler B -Office Basement 0 Accessory Structure* 0 Attached Garage 0 Detached Garage 0 Attached Carport 0 Detached Carport 0 Covered Deck 0 Uncovered Deck 0 PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): 84,975 Floor area of principal dwelling: 64,725 Floor area of accessory dwelling: 0 *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact: Handicap: Will there be a change in use? 0 Yes J No If "yes", explain: FIRE PROTECTION/HAZARDOUS MATERIALS: Sprinklers 0 Automatic Fire Alarm 0 None 0 Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? 0 Yes 0 No If `yes', attach list of materials and storage locations on a separate 8-1/2"x 11 "paper including quantities and Material Safety Data Sheets. SEPTIC SYSTEM 0 On-site Septic System — For on-site septic system, provide 2 copies of a current septic design approved by King County Health Department. H:\Applications\Forms-Applications On Line\2011 Applications\Permit Application Revised - 8-9-I I.docx Revised: August 2011 bh Page 2 of 4 Scope of Work (please provide detailed information): Addition of one sink Call before you Dig: 811 Please refer to Public Works. Bulletin #1 for fees and estimate sheet. Water District ❑ ...Tukwila 0 ...Water District #125 ❑ ...Water Availability Provided Sewer District ❑ ...Tukwila ❑ ...Sewer Use Certificate ❑ .. Highline ❑ ...Valley View ❑ .. Renton ❑ ... Sewer Availability Provided ❑ .. Renton ❑ .. Seattle Septic System: 0 On-site Septic System — For on-site septic system, provide 2 copies of a current septic design approved by King County Health Department. Submitted with Application (mark boxes which apply): ❑ ...Civil Plans (Maximum Paper Size — 22" x 34") ❑ ...Technical Information Report (Storm Drainage) ❑ ...Bond 0 .. Insurance 0 .. Easement(s) Proposed Activities (mark boxes that apply): ❑ ...Right-of-way Use - Nonprofit for less than 72 hours ❑ ...Right-of-way Use - No Disturbance ❑ ...Construction/Excavation/Fill - Right-of-way 0 Non Right-of-way 0 ❑ ...Total Cut ❑ ...Total Fill cubic yards cubic yards ❑ ...Sanitary Side Sewer ❑ ...Cap or Remove Utilities 0 ...Frontage Improvements ❑ ...Traffic Control 0 ...Backflow Prevention - Fire Protection Irrigation ❑ .. Geotechnical Report ❑ .. Maintenance Agreement(s) ❑...Traffic Impact Analysis ❑ ...Hold Harmless — (SAO) ❑ ...Hold Harmless — (ROW) ❑ .. Right-of-way Use - Profit for less than 72 hours ❑ .. Right-of-way Use — Potential Disturbance ❑ .. Work in Flood Zone ❑ .. Storm Drainage ❑ .. Abandon Septic Tank ❑.. Curb Cut 0 .. Pavement Cut ❑ .. Looped Fire Line 52 Domestic Water 21 SI ❑ ...Permanent Water Meter Size... WO # ❑ ...Temporary Water Meter Size .. 72 WO # ❑ ...Water Only Meter Size WO # ❑ ...Sewer Main Extension Public 0 Private 0 ❑ ...Water Main Extension Public 0 Private 0 ❑ .. Grease Interceptor ❑ .. Channelization 0 .. Trench Excavation ❑ .. Utility Undergrounding ❑ ...Deduct Water Meter Size FINANCE INFORMATION Fire Line Size at Property Line 0 ...Water 0 ...Sewer Monthly Service Billing to: Name: Number of Public Fire Hydrant(s) 0 ...Sewage Treatment Day Telephone: Mailing Address: City State Zip Water Meter Refund/Billing: Name: Mailing Address: Day Telephone: City State Zip H:\ Applications\Forms-Applications On Line\201 I Applications\Permit Application Revised - 8-9-11.docx Revised: August 2011 bh Page 3 of 4 Value of Construction — hi all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING O V OR AUT H 2IZED A( NT: 12 Signature: 7 ' ' /� / /V/'U Wf Date: 08/9312016 Print Name: ebecca Davidson / Day Telephone: (206) 267-6061 Mailing Address: 2385 82nd Ave. SE., Suite S-1 Mercer Island WA 98040 City H:\Applications\Forms-Applications On Line \201 I Applications\Permit Application Revised - 8-9-I l.docx Revised: August 2011 bh State Zip Page 4 of 4 Cash Register Receipt City of Tukwila DESCRIPTIONS PermitTRAK ACCOUNT QUANTITY PAID $804.47 D16-0231 Address: 16400 SOUTHCENTER PKWY 206 Apn: 2623049021 $804.47 DEVELOPMENT $804.47 PLAN CHECK FEE TOTAL FEES PAID BY RECEIPT: R9180 R000.345.830.00.00 0.00 $804.47 $804.47 Date Paid: Friday, August 12, 2016 Paid By: REBECCA DAVIDSON Pay Method: CREDIT CARD 04863D Printed: Friday, August 12, 2016 10:08 AM 1 of 1 CSYSTEMS Cash Register Receipt City of Tukwila Receipt Number R9307 DESCRIPTIONS I ACCOUNT I QUANTITY I PermitTRAK PAID $1,304.03 D16-0231 Address: 16400 SOUTHCENTER PKWY 206 Apn: 2623049021 $1,304.03 DEVELOPMENT $1,242.15 PERMIT FEE R000.322.100.00.00 0.00 $1,237.65 WASHINGTON STATE SURCHARGE B640.237.114 0.00 $4.50 TECHNOLOGY FEE $61.88 TECHNOLOGY FEE TOTAL FEES PAID BY RECEIPT: R9307 R000.322.900.04.00 0.00 $61.88 $1,304.03 Date Paid: Wednesday, August 31, 2016 Paid By: REBECCA DAVIDSON Pay Method: CREDIT CARD 14020G Printed: Wednesday, August 31, 2016 1:25 PM 1 of 1 CRWSYSTEMS INSPECTION RECORD Retain a copy with permit D'6 -Ong PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project: SP CII&Vr)' ' SU; re Type of Inspection: ,� ), ,)11.Do- )ij 4 -- Address: Address: MOO Sammc R Pv-wy Date Called: Special Instructions: d l1►/23/%6v Date Wanted: p.M. Requester:/ Phone No: tiQApproved per applicable codes. LJ Corrections required prior to approval. COMMENTS: Inspector: Awl Date: I Z 2 j J c REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit INSPON NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Proo ect::-- � d�"4T1 o IRE.Ci Type of Inspection: tlbt ri!t %/ - Adress: /64e nmm4eae P4 -ti Date Called: Special Instructions: Alie‘ Date Wanted: �f 4 Requester: Phone No: 56 Approved per applicable codes. LJ Corrections required prior to approval. COMMENTS: Inspector: Date: l(f z /6 REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPE ION NO INSPECTION RECORD Retain a copy with permit b1G - o2 1 PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 Permit Inspection Request Line (206) 438-9350 (206) 431-3670 Project: SPctuf.T1tx Co ITE. Type of Inspection: 6/A2 -'AJ -6 - Address: /Gi/'C Soup -0600e pY,tio7" Date Called: Special Instructions: Date Wante /O 2 / m part. Request : Phone No: Approved per applicable codes. Corrections required prior to approval. COMMENTS: Inspector: /I REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project: 5 P 'C(C., Ti Vic cu me' Type of Inspection: OZ/k"CI /f6" Address: /o ° Sot/Neat-0e Peal Date Called: Special Instructions: Wane Date Wanes :06. /G/' p.m. Requeste Phone No: ElApproved per applicable codes. ,l Corrections required prior to approval. COMMENTS: P/cvm6 SS�T�/ 61.40rAr6 ,a;:r' 12641r�s Inspector: Aim Date: 7/?t,// n REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 »&- 623i Project: SPCW �lTlt� rr Type 9J. spection: x 1I &- Address: /l4+v c►+cC Date Called: Special Instructions:GdtJir j,/c6 Date Wanted: Requester: Phone No: Approved per applicable codes. E Corrections required prior to approval. COMMENTS: Inspector:A) Date: 7/36/(4 l4 REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit INSP' tTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION Di/ -0Z3 6300 Southcenter Blvd., #100, Tukwila. WA 98188 Permit Inspection Request Line (206) 438-9350 (206) 431-3670 Project: SkeviA- 1 tfE' w'%?-' Type o spection: f-- 'AlvtIIISC- Address: 1alm P1&/ Date Called: Special Instructions:UV ,r yob Date Wanted: /6 a.m: Requester: Phone No: ElApproved per applicable codes. EJ Corrections required prior to approval. COMMENTS: auvtiai/AQ,- /a/64.4 /Ai ApPlailfait_ 126ittA2 Th Inspector: 43/4744 Date: n REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project: SPECO bevatre coin= Type o spection: ll 6 Address: Mee SeAlnicwrzfe PieL4)9 Date Called: Special Instructions: WALLS (� Date Wante d: j /q 2/ /i P.m. Requester: Phone No: 2s6- Ka zg14 Approved per applicable codes. Corrections required prior to approval. COMMENTS: Inspector:/ 4?) REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. d INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Ili& -02>i Prosect: SPCC UM -T1 tic SO / i e Type spection: llurC- Address: /61/06 cm-kicemele Pews Date Called: Special Instructions: at)f.` i/o& Date Wapte JG %� C� // a.r►.m p. Requeste : Phone No: IApproved per applicable codes. Corrections required prior to approval. COMMENTS: Rantg gtarri ervipg-- / d ,IPP as7A, L. tee SG! U(,>✓- %APeei1 Inspector: Date: /� `� fa. REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION NUMBER INSPECTION RECORD Retain a copy with permit /4--C /'24 /6-S- /w PERMIT NUMBERS CITY OF TUKWILA FIRE DEPARTMENT 206-575-4407 Project: Sprinklers: Tyke of Inspection: / Address:p %IId 5.c. Suite #: Lyroy Ftp✓ y Contact Person: Special Instruc ions: Phone No.: 4kpproved per applicable codes. Corrections required prior to approval. COMMENTS: SP- cAL4L, o Iz- Needs Shift Inspection: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: Inspector c..--7 Date: /07,-V/6 Hrs.: __ $100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. Billing Address Attn: Company Name: Address: City: State: Zip: Word/Inspection Record Form.Doc 3/14/14 T.F.D. Form F.P. 113 INSPECTION NUMBER INSPECTION RECORD Retain a copy with permit D/7- 0-2_5/ —s --/s), PERMIT NUMBERS CITY OF TUKWILA FIRE DEPARTMENT 206-575-4407 Project: Sprinklers: Fire Alarm: Type of Inspection: Address: /4x`00 Suite #: r ca6`j 6 'S C. e k__--.6,‘ f Contact Person: Special Instructions: Phone No.: Approved per applicable codes. Corrections required prior to approval. COMMENTS: ck Ali Needs Shift Inspection: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: Inspector: / (-,-- Date: 7/2)//6 Hrs.: $100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. Billing Address Attn: Company Name: Address: City: State: Zip: Word/Inspection Record Form.Doc 3/14/14 T.F.D. Form F.P. 113 PLAN It IIM/ESP_JPIING SLIP • PERMIT NUMBER: D16-0231 PROJECT NAME: SPECULATIVE SUITE DATE: 08/11/16 SITE ADDRESS: 16400 SOUTHCENTER PKWY, SUITE 406 X Original Plan Submittal Response to Correction Letter # Revision # Revision # before Permit Issued after Permit Issued DEPARTMENTS: kW& A-.1 q1140 Building Division A9 OM Public Works IL k'W& C 4 Fire Prevention Structural Planning Division Permit Coordinator n PRELIMINARY REVIEW: Not Applicable ❑ (no approval/review required) REVIEWER'S INITIALS: DATE: 08/16/16 Structural Review Required DATE: APPROVALS OR CORRECTIONS: Approved Corrections Required (corrections entered in Reviews) Notation: Approved with Conditions Denied (ie: Zoning Issues) 41-69 -�Id DUE DATE: 09/13/16 V n REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg 0 Fire 0 Ping 0 PW ❑ Staff Initials: 12/18/2013 D P INC GENERAL CONTRACTORS Home Espafiol Contact Search L&I Page 1 of 2 A -Z index Help My L&l Safety & Health Claims & Insurance Workplace Rights Trades & Licensing 0 Washington State Department of Labor & Industries D P INC GENERAL CONTRACTORS Owner or tradesperson Principals DODSON, WILLIAM, PRESIDENT Doing business as D P INC GENERAL CONTRACTORS WA USI No. 601 515 833 19936 BALLINGER WAY NE SEATTLE, WA 98155 206-361-2989 KING County Business type Corporation License Verify the contractor's active registration / license / certification (depending on trade) and any past violations. Construction Contractor Active. Meets current requirements. License specialties GENERAL License no. DPINCGC066BU Effective — expiration 01/31/1994— 01/31/2018 Bond Merchants Bonding Co (Mutual) Bond account no. WA28622 $12,000.00 Received by L&I Effective date 12/27/2012 01/31/2013 Expiration date Until Canceled Bond history Insurance Continental Western Ins Co $1,000,000.00 Policy no. CPA6015605 Received by L&I Effective date 08/04/2016 09/15/2016 Expiration date 09/15/2017 Continental Western Ins Co $1,000,000.00 Policy no. CWP6015605 Received by L&I Effective date 08/13/2015 09/15/2014 Expiration date 09/15/2016 https://secure.lni.wa.gov/verify/Detail.aspx?UBI=601515833&LIC=DPINCGC066BU&SAW= 8/31/2016 SOUTHCENTER PLACE EXISTING 5 -STORY OFFICE BUILDING • COMMON AND CORE AREAS, (N.I.C., TYP.) / NO CHANGE IN BUILDING AREA NO CORE / SHELL WORK NO STRUCTURAL WORK NO EXTERIOR WORK NO CHANGE OF USE OCCUPANT LOAD & EXITING: PER IBC TABLE 1004.1.2: BUSINESS AREA =100 SF PER OCCUPANT PER IBC TABLE 1015.1: 0-49 OCCUPANT LOAD = ONE (1) EXIT REQUIRED 50-500 OCCUPANT LOAD = TWO (2) EXITS REQUIRED 1,470 SF @ 1:100 =15 OCCUPANTS 1 EXIT REQUIRED, 1 EXIT PROVIDED PROJECT COMPLIES COMMON PATH OF EGRESS TRAVEL: PER IBC 1014.3: MAX. LENGTH =100'-0" FOR BUILDINGS WITH SPRINKLER SYSTEM LONGEST COMMON PATH OF EGRESS TRAVEL = ± 80' (SUITE 406) AND ± 67' (SUITE 405 PROJECT COMPLIES POINT WHERE 2 PATHS TO SEPARATE EXITS ARE AVAILABLE, TYP. EXIT ACCESS TRAVEL DISTANCE: PER IBC TABLE 1016.2: MAX. DISTANCE = 300'-0" FOR GROUP 'B' OCCUPANCY IN BUILDINGS WITH SPRINKLER SYSTEM PROJECT COMPLIES. w I - SEA -TAC CINTERNATIONAL AIRPORT NORTH 2 VICINITY MAP NTS P L STRANDER BLVD 238 ail I I -IT (11 l 11 I I rT[i 111111IIIIIIIIIIIIIF IIIIIIII11 111IIIIIL 1 U, SOUTHCENTER PLACE 16400 SOUTHCENTER PARKWAY TUKWILA, WA 98188 279 I I I U OUTBACK STEAK HOUSE NORTH EXITING PLAN AND OCCUPANCY LOAD CALCULATION 1/16" = 1'-0" 3 SITE PLAN 1" = 80'-0" EXISTING STRUCTURE METAL CLIP METAL STUDS STAGGERED @ 8'-0" O.C. FOR ALL UNBRACED STRAIGHT RUNS OF WALL OVER 12'-0". ATTACH TO STRUCTURE ABOVE. (2) #10 SCREWS SCHEDULED CEILING TILE & GRID 8' MAX 8' MAX 8' MAX 8' MAX 8' MAX 8' MAX�2' MAX ki'TO END OF WALL if 4: v � OMIT BRACING AT WALL LATERAL BRACING (STAGGERED) PER DETAIL ABOVE (TYP.) LATERAL WALL BRACING PLAN VIEW NTS TOP OF WALL NOTES: 1. LATERAL BRACING IS TO BE INSTALLED ON TENANT PARTITIONS AT 8 FEET O.C. EXCEPT AT INTERSECTIONS WITH WALLS AT LEAST 4 FEET LONG. (PER TYPICAL PARTITION PLAN) 2. PROVIDE BRACING AT ANY PERMANENT PARTITION THAT IS NOT ATTACHED TO CEILING GRID. a 4 STANDARD HEAD BRACING 1-1/2" =1'-0" ACT ACOUSTICAL CEILING TILE ADJ ADJACENT / ADJUSTABLE AFF ABOVE FINISH FLOOR ALT ALTERNATE ALUM ALUMINUM APPROX APPROXIMATELY AT BLDG BUILDING BLKG BLOCKING B/S BUILDING STANDARD CAB CABINET CLR CLEAR/CLEARANCE CLG CEILING CL CENTERLINE COL COLUMN COMM COMP CONST CONT CPT CT DIA DR DIM DW DWG E EA ELEC ELEC'L ELEV EQ EXIST EXT FIN FLR FLUOR FMC FR COMMUNICATION COMPOSITION CONSTRUCTION CONTINUOUS CARPET CERAMIC/CONCRETE TILE DIAMETER DOOR DIMENSION DISHWASHER DRAWING EXISTING / EAST EACH ELECTRIC ELECTRICAL ELEVATION (VIEW) EQUAL EXISTING EXTERIOR FINISH FLOOR FLUORESCENT FLOOR MATERIAL CHANGE FIRE RATED FT FURN GA GALV GD GL GWB HC HDW HM HT HVAC FEET FURNISH / FURNISHINGS GAUGE GALVANIZED GARBAGE DISPOSAL GLASS / GLAZING GYPSUM WALL BOARD HOLLOW CORE HARDWARE HOLLOW METAL HEIGHT HEATING, VENTILATING, AIR CONDITIONING IN INCH INCL INCLUDE INSUL INSULATION INT INTERIOR JT JOINT LL@TE BY LANDLORD AT TENANT'S EXPENSE LINEAL FOOT MAXIMUM MECHANICAL MANUFACTURER MINIMUM MISCELLANEOUS MARVIN STEIN ASSOCIATES MOUNTED METAL MICROWAVE OVEN NORTH/NEW NOT APPLICABLE NOT IN CONTRACT NUMBER NOMINAL NOT TO SCALE LF MAX MECH MFR MIN MISC MSA MTD MTL MW N N/A NIC NO NOM NTS OC ON CENTER OPNG OPENING OPP OPPOSITE 5 I ABBREVIATIONS ORIG PERM PL PLAM PLYWD PR PTN RB REF REFL'D REINF REQ'D REV RM RO S SCHED SC SECT SIM SPEC SQ STD STL STOR SUSP TEL TSG TYP UNO VCT VERT W/ W/O WC WD ORIGINAL PERMANENT PLATE PLASTIC LAMINATE PLYWOOD PAIR PARTITION RADIUS 1 REMOVE / RELOCATE RUBBER BASE REFRIGERATOR REFLECTED REINFORCING REQUIRED REVISION / REVERSE ROOM ROUGH OPENING SOUTH SCHEDULE SOLID CORE SECTION SIMILAR SPECIFICATION SQUARE STANDARD STEEL STORAGE SUSPENDED TELEPHONE TEMPERED SAFETY GLASS TYPICAL UNLESS NOTED OTHERWISE VINYL COMPOSITE TILE VERTICAL WEST WITH WITHOUT WALLCOVERING WOOD 1/4" NON-COMBUSTABLE WOOD FILLER UNDER MAIN RUNNERS. EXISTING CEILING SEISMIC BRACING (BEYOND) /`-7 PER 7/TI-1. CONTINUOUS 'L' METAL TRIM W/ PAPER WING (BOTH SIDES OF PARTITION) GALV. STEEL SILL TRACK. ATTACH TO STRUCTURE WITH HILTI X -U (OR XU15) UNIVERSAL KNURLED SHANK POWER DRIVEN FASTENER WITH MIN. 1" EMBEDMENT @ 16" O.C. (FOLLOW MANUFACTURER'S INSTRUCTIONS). FLOORING AS SCHEDULED (BOTH SIDES OF PARTITION) N STUD SCHEDULE STUD SCHEDULE: 2-1/2" = 250S125-27 (22 GA); MAX 10'-0" HIGH. 3-5/8" = 362S125-27 (22 GA); MAX 13'-0" HIGH. 6" = 600S125-27 (22 GA); MAX 17'-6" HIGH. NOTES: 1. ALL STUDS ARE AT 16" O.C. 2. USE SAME GAUGE AS STUDS FOR TRACKS AND CHANNEL. 3. USE SSMA TECHNICAL GUIDES. //7 %//%�/ 6 I STANDARD TENANT PARTITION 1/8" BLACK FOAM TAPE, HOLD BACK 1/4" FROM EDGE OF TRACK (BOTH SIDES) METAL TRACK WITH (2) #10 SCREWS AT 16" O.C. REVEAL (PAINT BLACK) OR MATCH EXISTING CONDITION. (BOTH SIDES OF PARTITION) 5/8" FIRE RETARDANT TREATED PLYWOOD BLOCKING AT WALL HUNG ITEMS (WHERE APPLICABLE- REFER TO DRAWING PLANS). ALTERNATE FOR BLOCKING: 20" WIDE SHEET METAL AT +40" FROM FLOOR TO BOTTOM (IN LIEU OF WOOD BLOCKING) 5/8" GWB, TYPE 'X' EACH SIDE BASE, AS SCHEDULED. (BOTH SIDES OF PARTITION.) EXISTING STRUCTURE (BELOW) GALV STEEL STUD, PER STUD SCHEDULE, WITH 5/8" TYPE 'X' GWB EACH SIDE. 4'-D" WIDE ACOUSTIC BATT INSULATION CENTERED OVER PARTITION ABOVE HUNG CEILING. 1/4" NON-COMBUSTABLE WOOD FILLER UNDER MAIN RUNNERS. EXISTING CEILING CONTINUOUS 'L' METAL TRIM W/ PAPER WING (BOTH SIDES OF PARTITION) / N I ACOUSTIC BATT INSULATION . GALV. STEEL SILL TRACK. ATTACH TO STRUCTURE WITH HILTI X -U (OR XU15) UNIVERSAL KNURLED SHANK POWER DRIVEN FASTENER WITH MIN. 1" EMBEDMENT @ 16" O.C. (FOLLOW MANUFACTURER'S INSTRUCTIONS). FLOORING AS SCHEDULED (BOTH SIDES OF PARTITION) STUD SCHEDULE STUD SCHEDULE: 2-1/2" = 250S125-27 (22 GA); MAX 10'-0" HIGH. 3-5/8" = 362S125-27 (22 GA); MAX 13'-0" HIGH. 6" = 600S125-27 (22 GA); MAX 17'-6" HIGH. NOTES: 1. ALL STUDS ARE AT 16" O.C. 2. USE SAME GAUGE AS STUDS FOR TRACKS AND CHANNEL. 3. USE SSMA TECHNICAL GUIDES. �j i /; SEISMIC BRACING (BEYOND) PER 7/TI-1. 1/8" BLACK FOAM TAPE, HOLD BACK 1/4" FROM EDGE OF TRACK (BOTH SIDES) METAL TRACK WITH (2) #10 SCREWS AT 16" O.C. REVEAL (PAINT BLACK) OR MATCH EXISTING CONDITION. (BOTH SIDES OF PARTITION) 5/8" FIRE RETARDANT TREATED PLYWOOD BLOCKING AT WALL HUNG ITEMS (WHERE APPLICABLE- REFER TO DRAWING PLANS). ALTERNATE FOR BLOCKING: 20" WIDE SHEET METAL AT +40" FROM FLOOR TO BOTTOM (IN LIEU OF WOOD BLOCKING) 5/8" GWB, TYPE 'X' EACH SIDE BASE, AS SCHEDULED. (BOTH SIDES OF PARTITION.) EXISTING STRUCTURE (BELOW) GALV STEEL STUD, PER STUD SCHEDULE, WITH 5/8" TYPE 'X' GWB EACH SIDE. PROJECT INFORMATION SCOPE OF WORK: ASSESSOR'S PARCEL NUMBER: LEGAL DESCRIPTION: CONSTRUCTION TYPE: OCCUPANCY TYPE: AREA OF SUITE: AREA OF FLOOR: APPLICABLE CODES: 11,011`) 116 BUILDING REPRESENTATIVE: DESIGNER: CONTRACTOR: TENANT IMPROVEMENT TO AN EXISTING SUITE ON THE 4TH FLOOR FOR OFFICE USE TO INCLUDE: • DEMISING OF AN EXISTING SUITE INTO TWO SMALLER SUITES - SUITES 405 AND 406 • DEMOLITION OF PARTITIONS, DOORS AND RELITES • CONSTRUCTION OF PARTITIONS, DOORS AND RELITES 262304-9021 PARCEL 1 OF CITY OF TUKWILA REVISED SHORT PLAT #77-51-55 AKA BLA #3-79 REC #7904180861 SD PLAT DAF - POR SE 1/4 OF NW 1/4 BEG AT MONUMENTAL INTSN OF C/L'S OF SOUTHCENTER PARKWAY 57TH AVE S & STRANDER BLVD S 164TH ST TH S 8-45-5 E 325.05 FT TH S 0-25-58 E 30 FT TO AN INTSN WITH S MGN SD STRANDER BLVD & TPOB TH CONTG S 0-25-58 E 200 FT TH S 89-45-58 E 350 FT TH S 0-25-58 E 1093.20 FT TH N 89-43-19 W 626.31 FT TO E ALG ARC OF CURVE TO RGT RAD 50 FT THRU C/A 91-11-50 79.53 FT TO S MGN STRANDER BKVD TH S 89-45-58 E 237.72 FT TO TPOB LESS POR OF SD PAR 1 FOR ST UNDER REC NO 8310250922 LESS RD PER SUP COURT #09-2-19459-9 KNT II -A, FULLY SPRINKLERED B, OFFICE 1,470 SQ.FT. ±13,700 SQ. FT. 2012 INTERNATIONAL BUILDING CODE (IBC) 2012 INTERNATIONAL FIRE CODE (IFC) 2012 INTERNATIONAL MECHANICAL CODE (IMC) ICC/ANSI 117.1- ACCESSIBLE AND USABLE BUILDINGS AND FACILITIES (11,0101) f2012 WASHINGTON STATE ENERGY CODE (WSEC) 2012 INTERNATIONAL FUEL AND GAS CODE (IFGC) 2012 UNIFORM PLUMBING CODE (UPC) 2014 NATIONAL ELECTRICAL CODE (NEC) WASHINGTON INDOOR AIR QUALITY CODE JOHN C. RADOVICH DEVELOPMENT COMPANY 2385 82ND AVENUE SE, SUITE 300, MERCER ISLAND, WA 98040 CONTACT - REBECCA DAVIDSON PHONE - 206.267.6060 EMAIL - rebeccadavidson@jcrdevco.com MARVIN STEIN ASSOCIATES, A NELSON COMPANY 1500 WESTLAKE AVENUE N, SUITE ONE, SEATTLE, WA 98109 CONTACT - LINDA DUCEY PHONE - 206.441.1449 EMAIL - I.ducey@marvinstein.com TBD GENERAL NOTES SEPARATE PERMIT IT REQUIRED FOR: Electrical Plumbing Gas Piping City of Tukwila 4BUILDIN3 DIVISION REVISIONS No changes shall be made to the scope of work without prior approval of Tukwila Building Division. NOTE: Revisions will require a new plan submittal and may include additional plan review fees. 1. COMPLY WITH ALL APPLICABLE CODES. 2. GENERAL CONTRACTOR SHALL VISIT JOB SITE AND VERIFY FIELD CONDITIONS PRIOR TO PURCHASING MATERIALS OR COMMENCING THE WORK. 3. REPORT ANY DISCREPANCIES BETWEEN ACTUAL FIELD CONDITIONS AND DRAWINGS TO MSA BEFORE PROCEEDING WITH THE WORK. 4. VERIFY THE BUILDING STANDARDS (B/S) BEFORE PROCEEDING WITH THE WORK. 5. OBTAIN ALL REQUIRED PERMITS AND APPROVALS BEFORE PROCEEDING WITH THE WORK. 6. WALLS, PARTITIONS AND CEILINGS SHALL BE INDEPENDENTLY BRACED TO RESIST SEISMIC FORCES. 7. PROVIDE BLOCKING AT ALL WALL MOUNTED ITEMS. 8. ALIGN AND SHIM TRANSITIONS BETWEEN OLD AND NEW CONDITIONS. 9. LEVEL THE FLOOR. DEVIATIONS OF ± 1/2" WITHIN 10'-0" IS THE ACCEPTABLE LIMIT. 10. GENERAL CONTRACTOR SHALL REVIEW AND STAMP OR MARK REQUIRED SUBMITTALS AND SHOP DRAWINGS PRIOR TO SENDING COPIES TO MSA FOR REVIEW AND COMMENT. 11. THE BUILDING OWNER OR THE OWNER'S AUTHORIZED REPRESENTATIVE SHALL ESTABLISH WORKING TIME AND STANDARDS OF CONDUCT. 12. DO NOT SCALE DRAWINGS. 13. GENERAL CONTRACTOR SHALL COORDINATE ACTIVITIES OF ALL SUBCONTRACTORS, DELIVERY, AND STAGING OF MATERIALS. MECHANICAL, PLUMBING, FIRE PROTECTION AND LIFE SAFETY NOTES 1. MECHANICAL, FIRE PROTECTION AND LIFE SAFETY ALTERATIONS AND CONSTRUCTION ARE BY OTHERS, UNDER SEPARATE PERMITS BY DESIGN / BUILD CONTRACTORS - DEFERRED SUBMITTALS. 2. REBALANCE THE HVAC SYSTEM AND PROVIDE WRITTEN REPORT TO OWNER AND/OR MSA. 3. CLEAN ALL DIFFUSERS & GRILLS. 4. VERIFY LOCATION OF THERMOSTATS WITH OWNER OR ARCHITECT PRIOR TO FINAL INSTALLATION. 5. ALL CONSTRUCTION WORK IS CONFINED TO THE BUILDING INTERIOR. CONTRACTOR SHALL PROVIDE BARRIERS OR SYSTEMS TO CONTAIN DUST, DIRT OR DEBRIS TO MINIMIZE INCONVENIENCE DURING CONSTRUCTION TO OTHER TENANTS WITHIN THE BUILDING. 6. CONSTRUCTION OPERATIONS SHALL NOT OBSTRUCT HALLWAYS, CORRIDORS, STAIRWAYS OR MEANS OF EGRESS FOR THE TENANTS OF THE BUILDING. 7. DO NOT DISRUPT HVAC, PLUMBING, ELECTRICAL OR FIRE PROTECTION SYSTEMS WITHOUT PRIOR AUTHORIZATION FROM THE BUILDING REPRESENTATIVE. 8. THE CONSTRUCTION SITE SHALL BE LEFT CLEAN & ORDERLY AT THE END OF EACH WORK DAY. 9. NO ONE WILL OCCUPY THE AREA OF WORK OTHER THAN AUTHORIZED CONSTRUCTION PERSONNEL. 10. THE GENERAL CONTRACTOR SHALL PROVIDE TEMPORARY CONSTRUCTION BARRIERS TO INHIBIT ACCESS BY NON -AUTHORIZED PERSONNEL AND AS REQUIRED BY O.S.H.A. STANDARDS TO PREVENT INJURIES OR ACCIDENTS. 11. N.F.P.A. / I.F.C. APPROVED FIRE EXTINGUISHERS SHALL BE LOCATED WITHIN 75 FEET FROM ANY POINT ALONG THE PATH OF TENANT EGRESS OR AS REQUIRED BY THE LOCAL FIRE MARSHAL. 12. THE SPACE AROUND PIPES DUCTS ETC. PENETRATING FIRE RESISTANT CONSTRUCTION SHALL NOT EXCEED'/" AND SHALL BE PACKED SOLID WITH APPROVED FIRE SAFING MATERIAL AND SEALED WITH METAL ESCUTCHEONS EACH SIDE AS REQUIRED BY CODE. 13. MAINTAIN INTEGRITY OF FIRE -RATED ASSEMBLIES AND REPAIR ANY DAMAGE TO SPRAY -APPLIED FIREPROOFING. SHEET INDEX TI -1 COVER SHEET AND DETAILS TI -2 DEMOLITION PLAN AND CONSTRUCTION PLAN TI -3 REFLECTED CEILING PLAN SOUTHCENTER PLACE 16400 SOUTHCENTER PARKWAY TUKWILA, WASHINGTON 98188 PILE Copy Permit No. i Plan review approval is subject to errors and omissions Approval of construction documents does not aU th the violation of any adopted code or ordinanc. , °ripe of approved Field Raeeipj and condi '.n. is a nowledged: 4 _1. .,/v. / Date:.., 71T City of Tukwila BUILDING DIVISION II Ii UI MARK DOUGLAS EVANS STATE. 01' WAS' IIN<i rON DRAWN BY: NG CHECKED BY: LD JOB NO.: 78011.151 NO. REVISIONS INDICATED THUS n DATE REVIEW SET PERMIT SET APPROVAL STAMPS: TENANT: 07/29/16 08/02/16 RECEIVED CITV t'')F Ti IKWU AUG 12 2016 PERMIT CENTER SPECULATIVE SPACE SUITE 406 SHEET TITLE: OUD Oi'51 COVER SHEET AND DETAILS 1-1/2" =1'-0" 7 1 STANDARD TENANT SOUND & DEMISING PTN .1-1/2"=l'-0" 8 1 PROJECT INFORMATION, NOTES & SHEET INDEX REPRODUCTION, ALTERATION OR PUBLICATION OF THIS DRAWING, WITHOUT EXPRESSED PERMISSION BY MSA, IS A VIOLATION OF FEDERAL COPYRIGHT LAW. COPYRIGHT BY MSA 2016. TI -1 OF 3 SOU THCENTER PLACE DEMOLITION PLAN 1/8" =1'-0" 0 5' 10' 20' DEMOLITION LEGEND EXISTING BUILDING CORE EXISTING CORRIDOR PARTITION EXISTING DEMISING PARTITION EXISTING PARTITION c EXISTING B/S 2'-6" WIDE x FULL -HEIGHT RELITE = EXISTING CONSTRUCTION TO BE DEMOLISHED 30' DEMOLITION NOTES 1. A CLEAR PATH OF EGRESS TRAVEL SHALL REMAIN OPEN AT ALL TIMES DURING DEMOLITION. 2. DISRUPTION OF THE BUILDING FIRE ALARM, ELECTRICAL POWER, WATER, OR LIFE SAFETY SYSTEMS MUST BE COORDINATED WITH ALL GOVERNING AGENCIES AND THE BUILDING REPRESENTATIVE. 3. ALL DEBRIS SHALL BE REMOVED FROM THE DEMOLITION SITE DAILY. 4. ALL DEMOLITION SHALL BE PERFORMED IN ACCORDANCE WITH THE BUILDING REPRESENTATIVE'S RULES AND REGULATIONS WITH MINIMAL DISTURBANCE TO OTHER TENANTS. 5. CONTRACTOR SHALL PROVIDE DUST BARRIERS FOR PROTECTION OF EXISTING ADJACENT AREAS. ALL HVAC SYSTEMS ARE TO BE PROTECTED DURING DEMOLITION. 6. CONTRACTOR SHALL NOTIFY BUILDING REPRESENTATIVE AND MSA OF ANY DEMOLITION WORK THAT IMPACTS THE STRUCTURAL INTEGRITY OF THE BUILDING. 7. GENERAL CONTRACTOR SHALL IMMEDIATELY REPORT ALL ACCIDENTS, ERRORS OR DEFECTS TO THE BUILDING REPRESENTATIVE. NORTH DEMOLITION KEYNOTES CEXISTING CASEWORK TO REMAIN. BREAK RECEPTION OPEN WORK AREA EXISTING OFFICE CONSTRUCTION PLAN 1/8" =1'-0" 0 5' 10' 20' CONSTRUCTION LEGEND c R/N FEC EXISTING BUILDING CORE EXISTING CORRIDOR PARTITION EXISTING DEMISING PARTITION EXISTING PARTITION EXISTING B/S 2'-6" WIDE x FULL -HEIGHT RELITE NEW B/S DEMISING PARTITION PER DETAIL 7/TI-1 NEW B/S TENANT INTERIOR PARTITION PER DETAIL 6/TI-1 NEW B/S SOUND PARTITION PER DETAIL 7/TI-1 RELOCATED OR NEW B/S 2'-6" WIDE x FULL -HEIGHT TEMPERED SAFETY GLASS RELITE PROPOSED LOCATION OF EXISTING FIRE EXTINGUISHER. VERIFY FINAL LOCATION WITH TENANT AND/OR FIRE DEPARTMENT INSPECTOR. ALIGN CONSTRUCTION NOTES 1. MAINTAIN A CLEAR PATH OF TRAVEL AT ALL TIMES DURING CONSTRUCTION. 2. DISRUPTION OF THE BUILDING FIRE ALARM, ELECTRICAL POWER, WATER, OR LIFE SAFETY SYSTEMS MUST BE COORDINATED WITH ALL GOVERNING AGENCIES & THE BUILDING OWNER / MANAGEMENT AND TENANT. 3. INSTALL DOUBLE STUDS AT DOOR JAMBS AND HEADERS. 4. DIMENSIONS ARE FINISH SURFACE TO FINISH SURFACE, U.N.O. 5. REPORT ANY DISCREPANCIES BETWEEN THE DRAWINGS AND ACTUAL FIELD CONDITIONS TO MSA. 6. ALL EXISTING WINDOW COVERINGS TO BE CLEANED AND IN GOOD WORKING ORDER. 30' DOOR SCHEDULE NORTH oFo 0111010 P.,G2,62016 oi100 a ItONG owesoa DOOR NUMBER 4' TYPE OF DOOR A. RELOCATED B/S 3'-0" WIDE SC WOOD DOOR IN RELOCATED B/S WOOD FRAME J HARDWARE a. B/S LATCHSET 6", UNLESS OTHERWISE NOTED EXISTING DOOR TO REMAIN CONSTRUCTION KEYNOTES C C C C EXISTING CASEWORK TO REMAIN. ALIGN NEW PARTITION AT CORNER. UPGRADE EXISTING PARTITION TO MATCH B/S DEMISING PARTITION. PROVIDE AND INSTALL GLASS INSERT TO EXISTING DOOR TO MATCH B/S SUITE ENTRY DOORS. NOTES: 1. PROVIDE CODE COMPLIANT HARDWARE. ALL HARDWARE TO BE LEVER -TYPE. HANDLES, PULLS, LATCHES, LOCKS, AND OTHER OPERABLE PARTS ON ACCESSIBLE DOORS SHALL HAVE A SHAPE THAT IS EASY TO GRASP WITH ONE HAND AND DOES NOT REQUIRE TIGHT GRASPING, PINCHING, OR TWISTING OF THE WRIST TO OPERATE. OPERABLE PARTS OF SUCH HARDWARE SHALL BE 34" MIN. AND 48" MAX. ABOVE THE FLOOR. 2. THE MAXIMUM FORCE FOR PUSHING OR PULLING OPEN DOORS OTHER THAN FIRE DOORS SHALL BE AS FOLLOWS: INTERIOR HINGED DOOR = 5.0 POUNDS (22.2 N), SLIDING OR FOLDING DOOR = 15.0 POUNDS (67 N). THESE FORCES DO NOT APPLY TO THE FORCE REQUIRED TO RETRACT LATCH BOLTS OR DISENGAGE OTHER DEVICES THAT HOLD THE DOOR IN A CLOSED POSITION. FIRE DOORS SHALL HAVE A MINIMUM OPENING FORCE ALLOWABLE BY THE APPROPRIATE ADMINISTRATIVE AUTHORITY. 3. THRESHOLDS AT DOORWAYS SHALL NOT EXCEED 0.5 INCH (12.7 MM) IN HEIGHT. RAISED THRESHOLDS AND FLOOR LEVEL CHANGES GREATER THAN 0.25 INCH (6.4 MM) AT DOORWAYS SHALL BE BEVELED WITH A SLOPE NOT GREATER THAN ONE UNIT VERTICAL IN TWO UNITS HORIZONTAL (50 -PERCENT SLOPE). 4. EXIT DOORS MUST REMAIN UNLOCKED AT ALL TIMES IN THE DIRECTION OF EGRESS. PASSAGE EXIT HARDWARE SHALL REQUIRE NO SPECIAL KNOWLEDGE OR ASSISTANCE TO OPEN OR TO ACCESS. SOUTHCENTER PLACE 16400 SOUTHCENTER PARKWAY TUKWILA, WASHINGTON 98188 8459 8E0811:All) nl '_.. MAR DOUGLAS STATE. OF WASIIINGTON DRAWN BY: NG CHECKED BY: LD JOB NO.: 78011.151 NO. REVISIONS INDICATED THUS n DATE BY REVIEW SET PERMIT SET 07/29/16 08/02/16 NG TA APPROVAL STAMPS: TENANT: RECEIVED CANT ur I UKWILA AUG 12 2016 PERMIT CENTER SPECULATIVE SPACE SUITE 406 SHEET TITLE: D« - o2:31 DEMOLITION AND CONSTRUCTION PLANS REPRODUCTION, ALTERATION OR PUBLICATION OF THIS DRAWING, WITHOUT EXPRESSED PERMISSION BY MSA, IS A VIOLATION OF FEDERAL COPYRIGHT LAW. COPYRIGHT BY MSA 2016. TI -2 OF 3 SOUTHCENTER PLACE REFLECTED CEILING PLAN 1/8" =1'-0" 0 5' 10' 20' CEILING LEGEND I/ I EXISTING CEILING GRID AND TILES TO REMAIN EXISTING GYP. BOARD FINISHED CEILING EXISTING 2'x4' RECESSED FLUORESCENT LIGHT FIXTURES TO BE REMOVED NEW B/S 2'x4' RECESSED FLUORESCENT LIGHT FIXTURES NEW B/S 2'x4' RECESSED FLUORESCENT LIGHT FIXTURES TO BE UPGRADED FOR EMERGENCY LIGHTING. LAYOUT SHOWN IS CONCEPTUAL ONLY. 0 EXISTING B/S ILLUMINATED EXIT SIGN (DIRECTIONAL WHERE SHOWN) IFf?•(M,N) B/S LIGHT SWITCH (M = SUITE MASTER, N = NEW) CEILING KEYNOTES 0 REMOVE EXISTING EXISTING LIGHT FIXTURES AS SHOWN, PROVIDE AND INSTALL NEW B/S LIGHT FIXTURES. 30' inon CEILING NOTES MIN 1. CHECK FOR CONFLICTS BEFORE INSTALLING OR RELOCATING LIGHT FIXTURES. NOTIFY MSA OF ANY CONFLICT(S). 2. REPLACE DAMAGED CEILING TILES AND GRID AS NECESSARY TO BRING CEILING TO "LIKE NEW" CONDITION. 3. MAINTAIN EXISTING ONE FOOTCANDLE PER SQUARE FOOT AT EGRESS PATHWAY LIGHTING. 4. MAINTAIN 42" CLEAR SPACE IN FRONT OF THE PANEL SIDE OF ANY V.A.V. BOXES. 5. DAYLIGHT ZONE CONTROL: DAY LIGHTING AS DEFINED BY CODE SHALL BE PROVIDED WITH INDIVIDUAL CONTROLS, OR DAYLIGHT OR OCCUPANT SENSING AUTOMATIC CONTROLS PER SECTION C405.2.2.2 OF THE WASHINGTON STATE ENERGY CODE. 6. FIRE SPRINKLER INSTALLATION TO BE DESIGN -BUILD WITH DEFERRED PERMIT SUBMITTALS. 7. COMMISSIONING REQUIREMENTS: TEST LIGHTING CONTROLS TO ENSURE THAT THE SYSTEMS COMPLY WITH CODES. PROVIDE A WRITTEN REPORT OF TEST PROCEDURES AND RESULTS TO THE OWNER. USE OCCUPANCY SENSORS AS REQUIRED. 8. EXIT SIGNS ARE INDICATED ON THE REFLECTED CEILING PLAN. THEIR FINAL PLACEMENT IS TO BE COORDINATED IN THE FIELD WITH THE INSPECTOR. U NORTH LIGHTING CALCULATION SYMBOL USED WATTS/ FIXTURE # OF FIXTURES TOTAL WATTS 0 34 17 578 Il 1 0 ALLOWABLE WATTAGE: 1,470 SF x 0.9 WATT PER SF = 1,323 WATTS PROPOSED WATTAGE: 578 WATTS SUMMARY: TOTAL PROPOSED WATTAGE IS LESS THAN THE ALLOWABLE WATTAGE PER 2012 WSEC INTERIOR LIGHTING POWER C405.5.2 (TABLE C405.5.2(1)). PER ELEVATION CD M N C' M 36" 36" 1't • MAX. DIM. 36" I 37" ELEVATION 3/8" =1'-0" 25" MELAMINE INTERIOR AS SCHEDULED 0 0 CD MIN DIM. 24" )' 3" SECTION 1-1/2" =1'-0" PLAM FILLER PANEL. ENSURE FULL OPERATION OF DOORS, TYP. NOTES: 1. PROVIDE FINISHED ENDS ON ALL EXPOSED SURFACES, TYP. 2. PROVIDE FILLER PANELS AS NECESSARY, TYP. PLAM COUNTERTOP AND 3/4" BACKSPLASH. DRAWER ON (75) POUND FULL- EXTENSION SLIDE. B/S ADA -COMPLIANT CASEWORK HARDWARE, TYP. (2) CONCEALED HINGES PER DOOR. ADJUSTABLE SHELF WITH MELAMINE FINISH. CABINET DOORS. P -LAM FINISH ON EXPOSED FACE WITH MATCHING EDGE BANDING AND MELAMINE FINISH ON INTERIOR FACE. Tom„ 1/4" PLYWOOD BACKING WITH MELAMINE FINISH. BASE AS SCHEDULED. 3/4" PLAM BACKSPLASH. PER ELEVATION MIN. DIM. PROTECTIVE COVERING AT EXPOSED PIPES. 1/4" PLYWOOD BACKING WITH MELAMINE FINISH. DASHED LINES co INDICATE REQUIRED ACCESSIBLE CLEARANCES. CONTINUE FINISH FLOOR BELOW SINK RESILIENT BASE, PER SCHEDULE. 12" (INSIDE CLEAR) o 01 o 0 0 0 0 0 0 0 0 0 0 0 0 0 0 C7 10 0 0 0 0 0 0 C-4 SECTION 1-1/2" =1'-0" 25" (2) B/S CONCEALED HINGES PER DOOR. 1/4" PLYWOOD BACKING WITH MELAMINE FINISH. 3/4" PLYWOOD ADJUSTABLE SHELF WITH FINISH MELAMINE FINISH. MELAMINE INTERIOR. CABINET DOORS. P -LAM FINISH ON EXPOSED FACE WITH MATCHING B/S EDGE BANDING AND MELAMINE FINISH ON INTERIOR FACE. B/S ADA -COMPLIANT CASEWORK HARDWARE. 24" 6" MIN. CLR. \I B/S S.S. FAUCET & SINK PER ANSI 117.1 CODE COMPLIANCE B/S PLAM TBD> COUNTERTOP, PER SCHEDULE. B/S ADA- COMPLIANT CASEWORK HARDWARE 8" MIN. CLR. (2) CONCEALED HINGES PER EACH DOOR. CABINET DOORS. P -LAM FINISH ON EXPOSED FACE WITH MATCHING z_ EDGE BANDING AND MELAMINE i FINISH ON INTERIOR FACE. SECTION 1-1/2" =1'-0" ATTACH BASE TO DOOR. CUT BASE SHORT FOR PROPER DOOR OPERATION. SOUTHCENTER PLACE 16400 SOUTHCENTER PARKWAY TUKWILA, WASHINGTON 98188 8459 RliliIS I'1?Il. fi•FP-. 1 ..• I R DOUGLAS EVANS SPATE OF \NASIHN(F I'ON • DRAWN BY: NG CHECKED BY: LD JOB NO.: 78011.151 NO. REVISIONS INDICATED THUS n DATE BY REVIEW SET PERMIT SET 07/29/16 08/02/16 NG TA APPROVAL STAMPS: TENANT: RECEIVED CITY OF TUKWILA AUG 12 2016 PERMIT CENTER SPECULATIVE SPACE SUITE 406 SHEET TITLE: IN(p-O-1-3/ REFLECTED CEILING PLAN, ELEVATION AND SECTIONS REPRODUCTION, ALTERATION OR PUBLICATION OF THIS DRAWING, WITHOUT EXPRESSED PERMISSION BY MSA, IS A VIOLATION OF FEDERAL COPYRIGHT LAW. COPYRIGHT BY MSA 2016. TI -3 OF 3