Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Permit D16-0235 - MUSEUM OF FLIGHT - FIRST FLOOR TENANT IMPROVEMENT
MUSEUM OF FLIGHT 9404 E MARGINAL WAY S D16-0235 Parcel No: Address: City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-438-9350 Web site: http://www.TukwilaWA.gov DEVELOPMENT PERMIT 3324049019 Permit Number: D16-0235 9404 E MARGINAL WAY S Project Name: MUSEUM OF FLIGHT Issue Date: 9/20/2016 Permit Expires On: 3/19/2017 Owner: Name: Address: Contact Person: Name: Address: Contractor: Name: Address: License No: Lender: Name: Address: MUSEUM OF FLIGHT FOUNDATION 9404 EAST MARGINAL WY S , SEATTLE, WA, 98108 PIA WESTEN 1050 N 38TH ST, SEATTLE, WA, 98103 BNBUILDERS 2601 4TH AVE SUITE 350, SEATTLE, WA, 98121 BNBUII*990K3 MUSEUM OF FLIGHT 9404 E MARGINAL WAYS , TUKWILA, WA, 98108 Phone: (206) 224-3316 Phone: (206) 382-3443 Expiration Date: 9/12/2017 DESCRIPTION OF WORK: PARTIAL FIRST FLOOR TENANT IMPROVEMENT CONSISTING OF PROPOSED BATHROOMS AND A FIRST AID ROOM. Project Valuation: $310,000.00 Type of Fire Protection: Sprinklers: YES Fire Alarm: YES Type of Construction: IIA Electrical Service Provided by: TUKWILA Fees Collected: $5,608.72 Occupancy per IBC: A-3 Water District: TUKWILA Sewer District: TUKWILA Current Codes adopted by the City of Tukwila: International Building Code Edition: International Residential Code Edition: International Mechanical Code Edition: Uniform Plumbing Code Edition: International Fuel Gas Code: 2015 2015 2015 2015 2015 National Electrical Code: WA Cities Electrical Code: WAC 296-46B: WA State Energy Code: 2014 2014 2014 2015 Public Works Activities: Channelization/Striping: Curb Cut/Access/Sidewalk: Fire Loop Hydrant: Flood Control Zone: Hauling/Oversize Load: Land Altering: Landscape Irrigation: Sanitary Side Sewer: Sewer Main Extension: Storm Drainage: Street Use: Water Main Extension: Water Meter: Volumes: Cut: 0 Fill: 0 Number: 0 No Permit Center Authorized Signature: €'- Date: 7/(71,606 I hearby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this development per ► d agree to the conditions attached to this permit. Signature: Print Name: MA 11 /gNKr Ovr°--- Date: 9'1a This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: ***BUILDING PERMIT CONDITIONS*** 2: Work shall be installed in accordance with the approved construction documents, and any changes made during construction that are not in accordance with the approved construction documents shall be resubmitted for approval. 3: All permits, inspection record card and approved construction documents shall be kept at the site of work and shall be open to inspection by the Building Inspector until final inspection approval is granted. 4: New suspended ceiling grid and light fixture installations shall meet the seismic design requirements for nonstructural components. ASCE 7, Chapter 13. 5: Partition walls shall not be tied to a suspended ceiling grid. All partitions greater than 6 feet in height shall be laterially braced to the building structure. Such bracing shall be independent of any ceiling splay bracing. 6: Insulating materials, where exposed as installed in buildings of any type of construction, shall have a flame spread index of not more than 25 and a smoke development index of not more than 450. Where facings are installed in concealed spaces in buildings of Type III, IV, or V construction, the flame spread and smoke - developed limitations do not apply to facings, that are installed behind and in substantial contact with the unexposed surface of the ceiling, wall or floor finish. 7: All construction shall be done in conformance with the Washington State Building Code and the Washington State Energy Code. 8: Fire retardant treated wood shall have a flame spread of not greater than 25. All materials shall bear identification showing the fire performance rating thereof. Such identification shall be issued by an approved agency having a service for inspection at the factory. 26: Emergency lighting facilities shall be arranged to provide initial illumination that is at least an average of 1 foot-candle (11 lux) and a minimum at any point of 0.1 foot-candle (1 lux) measured along the path of egress at floor level. Illumination levels shall be permitted to decline to 0.6 foot-candle (6 lux) average and a minimum at any point of 0.06 foot-candle (0.6 lux) at the end of the emergency lighting time duration. A maximum-to-minimum illumination uniformity ratio of 40 to 1 shall not be exceeded. (IFC 1006.3.1) 30: Fire protection systems shall be maintained in accordance with the original installation standards for that system. Required systems shall be extended, altered or augmented as necessary to maintain and continue protection whenever the building is altered, remodeled or added to. Alterations to fire protection systems shall be done in accordance with applicable standards. (IFC 901.4) 28: Sprinklers shall be installed under fixed obstructions over 4 feet (1.2 m) wide. (NFPA 13-8.6.5.3.3) 27: All new sprinkler systems and all modifications to existing sprinkler systems shall have fire department review and approval of drawings prior to installation or modification. New sprinkler systems and all modifications to sprinkler systems involving more than 50 heads shall have the written approval of Factory Mutual or any fire protection engineer licensed by the State of Washington and approved by the Fire Marshal prior to submittal to the Tukwila Fire Prevention Bureau. No sprinkler work shall commence without approved drawings. (City Ordinance No. 2436). 31: A fire alarm system is required for this project. The fire alarm system shall meet the requirements of N.F.P.A. 72 and City Ordinance #2437. 33: Maintain fire alarm system audible/visual notification. Addition/relocation of walls or partitions may require relocation and/or addition of audible/visual notification devices. (City Ordinance #2437) 32: All new fire alarm systems or modifications to existing systems shall have the written approval of The Tukwila Fire Prevention Bureau. No work shall commence until a fire department permit has been obtained. (City Ordinance #2437) (IFC 901.2) 34: An electrical permit from the City of Tukwila Building Department Permit Center (206-431-3670) is required for this project. 35: All electrical work and equipment shall conform strictly to the standards of the National Electrical Code. (NFPA 70) 36: The maximum flame spread class of finish materials used on interior walls and ceilings shall not exceed that set forth in Table No. 803.9 of the International Building Code. 29: Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (City Ordinances #2436 and #2437) 37: Any overlooked hazardous condition and/or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. 38: These plans were reviewed by Inspector 511. If you have any questions, please call Tukwila Fire Prevention Bureau at (206)575-4407. PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 1700 BUILDING FINAL** 0301 CONCRETE SLAB 0611 EMERGENCY LIGHTING F&S RESISTANT PEN 1400 FIRE FINAL 0409 FRAMING LATH & GYPSUM 0406 SUSPENDED CEILING 0601 WALL INSULATION 9: Special inspection for sprayed fire-resistant materials applied to structural elements and decks is required. Special inspections shall be based on the fire -resistance design as designated in the approved construction documents. 10: There shall be no occupancy of a building until final inspection has been completed and approved by Tukwila building inspector. No exception. 11: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of this requirement. 12: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206-431-3670). 13: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center. 14: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 15: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431-3670). 16: The total number of fire extinguishers required for a light hazard occupancy with Class A fire hazards is calculated at one extinguisher for each 3,000 sq. ft. of area. The extinguisher(s) should be of the "all purpose" (2A, 10 B:C) dry chemical type. The travel distance to any extinguisher must be 75' or less. (IFC 906.3) (NFPA 10, 5.4) 17: Maintain fire extinguisher coverage throughout. 18: Egress doors shall be readily openable from the egress side without the use of a key or special knowledge or effort. (IFC 1008.1.8.3 subsection 2.2) 19: Dead bolts are not allowed on auxiliary exit doors unless the dead bolt is automatically retracted when the door handle is engaged from inside the tenant space. (IFC Chapter 10) 20: Exit hardware and marking shall meet the requirements of the International Fire Code. (IFC Chapter 10) 21: Door handles, pulls, latches, locks and other operating devices on doors required to be accessible by Chapter 11 of the International Building Code shall not require tight grasping, tight pinching or twisting of the wrist to operate. (IFC 1008.1.9.1) 22: Exits and exit access doors shall be marked by an approved exit sign readily visible from any direction of egress travel. Access to exits shall be marked by readily visible exit signs in cases where the exit or the path of egress travel is not immediately visible to the occupants. Exit sign placement shall be such that no point in an exit access corridor is more than 100 feet (30,480 mm) or the listed viewing distance for the sign, whichever is less, from the nearest visible exit sign. (IFC 1011.1) 23: Every exit sign and directional exit sign shall have plainly legible letters not less than 6 inches (152 mm) high with the principal strokes of the letters not less than 0.75 inch (19.1 mm) wide. The word "EXIT" shall have letters having a width not less than 2 inches (51 mm) wide except the letter "I", and the minimum spacing between letters shall not be less than 0.375 inch (9.5 mm). Signs larger than the minimum established in section 1011.5.1 of the International Fire Code shall have letter widths, strokes and spacing in proportion to their height. The word "EXIT" shall be in high contrast with the background and shall be clearly discernible when the exit sign illumination means is or is not energized. If an arrow is provided as part of the exit sign, the construction shall be such that the arrow direction cannot be readily changed. (IFC 1011.6) 24: Aisles and aisle access ways serving as a portion of the exit access in the means of egress system shall comply with the requirements of this section. Aisles or aisle access ways shall be provided from all occupied portions of the exit access which contain seats, tables, furnishings, displays and similar fixtures or equipment. The required width of aisles shall be unobstructed. (IFC 1017.1) 25: Exit signs shall be illuminated at all times. To ensure continued illumination for a duration of not less than 90 minutes in case of primary power loss, the sign illumination means shall be connected to an emergency power system provided from storage batteries, unit equipment or on-site generator. (IFC 1011.6.3) CITY OF TUKh .A Community Development Department Public Works Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http ://www.TukwilaWA. go v Building Permit No. D16-00)-35) Project No. , Date Application Accepted: off% % (/(p Date Application Expires: p d-//9// 7 (For office use only) CONSTRUCTION PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **Please Print** SITE LOCATION Site Address: 9404 E Marginal Way S Tenant Name: Museum of Flight PROPERTY OWNER Name: Pia Westen Name: Museum of Flight City: Seattle State: WA Zip: 98103 Address: 9404 E Marginal Way Email: piaw@shksarchitects.com City: Seattle State: WA Zip: 98108 CONTACT PERSON — person receiving all project communication Name: Pia Westen Address: 1050 N 38th St City: Seattle State: WA Zip: 98103 Phone: (206) 224-3316 Fax: Email: piaw@shksarchitects.com GENERAL CONTRACTOR INFORMATION Company Name: BNBuilders Address: 2601 4th Ave, Suite 350 City: Seattle State: WA Zip: 98121 Phone: (206) 382-3443 Fax: Contr Reg No.: BNBUlI*990K3 Exp Date: 09/12/2017 Tukwila Business License No.: BUS -0992476 H:\Applications\Forms-Applications On Line \2011 Applications\Permit Application Revised - 8-9-I I.docx Revised: August 2011 bh King Co Assessor's Tax No.: 3324049019 Suite Number: Floor: New Tenant: ❑ Yes ❑..No ARCHITECT OF RECORD Name: N/A ► v G V s_t4 I'v 64' "ttit. Company Name: SHKS Architects Company Name: NA Architect Name: David Strauss Address: 1050 N 38th St City: Seattle State: WA Zip: 98103 Phone: (206) 675-9151 Fax: Email: dstrauss@shksarchitects.com State: ENGINEER OF RECORD Name: N/A ► v G V s_t4 I'v 64' "ttit. Address: a/4i 1 l%1 G. vi 0,1 Vial Company Name: NA Engineer Name: Address: City: State: Zip: Phone: Fax: Email: LENDER/BOND ISSUED (required for projects $5,000 or greater per RCW 19.27.095) Name: N/A ► v G V s_t4 I'v 64' "ttit. Address: a/4i 1 l%1 G. vi 0,1 Vial City: 5,m,t(?/ State: v vl Zip:12,, D g Page 1 of 4 BUILDING PERMIT INFORMATIC )206-431-3670 Valuation of Project (contractor's bid price): $ 310,000 Existing Building Valuation: $ 94,231,600 Describe the scope of work (please provide detailed information): PARTIAL FIRST FLOOR TENANT IMPROVEMENT CONSISTING OF PROPOSED BATHROOMS AND A FIRST AID ROOM. Will there be new rack storage? ❑ Yes 0.. No If yes, a separate permit and plan submittal will be required. Provide All Building Areas in Square Footage Below PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq fl.): Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact: Handicap: Will there be a change in use? 0 Yes 0 No If "yes", explain: FIRE PROTECTION/HAZARDOUS MATERIALS: m Sprinklers ® Automatic Fire Alarm 0 None ❑ Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes No If `yes', attach list of materials and storage locations on a separate 8-1/2"x 11 "paper including quantities and Material Safety Data Sheets. SEPTIC SYSTEM 0 On-site Septic System — For on-site septic system, provide 2 copies of a current septic design approved by King County Health Department. H:\Applications\Fortes-Applications On Line\2011 Applications\Permit Application Revised - 8-9-I I.docx Revised: August 2011 bh Page 2 of 4 Existing Interior Remodel Addition to Existing Structure New Type of Construction per IBC Type of Occupancy per IBC 1st Floor 86,000 1,650 0 0 IIA A 2nd Floor 3rd Floor Floors thru_ Basement 75,300 1,870 0 0 IIA B Accessory Structure* Attached Garage Detached Garage Attached Carport Detached Carport Covered Deck Uncovered Deck PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq fl.): Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact: Handicap: Will there be a change in use? 0 Yes 0 No If "yes", explain: FIRE PROTECTION/HAZARDOUS MATERIALS: m Sprinklers ® Automatic Fire Alarm 0 None ❑ Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes No If `yes', attach list of materials and storage locations on a separate 8-1/2"x 11 "paper including quantities and Material Safety Data Sheets. SEPTIC SYSTEM 0 On-site Septic System — For on-site septic system, provide 2 copies of a current septic design approved by King County Health Department. H:\Applications\Fortes-Applications On Line\2011 Applications\Permit Application Revised - 8-9-I I.docx Revised: August 2011 bh Page 2 of 4 PUBLIC WORKS PERMIT INFORMATION — 206-433-0179 Scope of Work (please provide detailed information): Call before you Dig: 811 Please refer to Public Works Bulletin #1 for fees and estimate sheet. Water District ❑ ...Tukwila ❑ ...Water District #125 ❑ ...Water Availability Provided Sewer District ❑ ...Tukwila ❑ ...Sewer Use Certificate ❑ .. Highline ❑...Valley View ❑ .. Renton ❑ ... Sewer Availability Provided ❑ .. Renton ❑ .. Seattle Septic System: ❑ On-site Septic System — For on-site septic system, provide 2 copies of a current septic design approved by King County Health Department. Submitted with Application (mark boxes which apply): ❑ ...Civil Plans (Maximum Paper Size — 22" x 34") ❑ ...Technical Information Report (Storm Drainage) ❑ .. Geotechnical Report ❑ ...Bond ❑ .. Insurance ❑ .. Easement(s) ❑ .. Maintenance Agreement(s) Proposed Activities (mark boxes that apply): ❑ ...Right-of-way Use - Nonprofit for less than 72 hours ❑ ...Right-of-way Use - No Disturbance ❑ ...Construction/Excavation/Fill - Right-of-way ❑ Non Right-of-way ❑ ❑ ...Total Cut ❑ ...Total Fill cubic yards cubic yards ❑ ...Sanitary Side Sewer ❑ ...Cap or Remove Utilities ❑ ...Frontage Improvements ❑ ...Traffic Control ❑ ...Backflow Prevention - Fire Protection Irrigation Domestic Water ❑ ...Permanent Water Meter Size... ❑ ...Temporary Water Meter Size.. ❑ ...Water Only Meter Size ❑ ...Sewer Main Extension Public ❑ ❑ ...Water Main Extension Public ❑ ❑ ...Traffic Impact Analysis ❑ ... Hold Harmless — (SAO) ❑ ... Hold Harmless — (ROW) ❑ .. Right-of-way Use - Profit for less than 72 hours ❑ .. Right-of-way Use — Potential Disturbance ❑ .. Work in Flood Zone ❑ .. Storm Drainage ❑ .. Abandon Septic Tank ❑ .. Curb Cut ❑ .. Pavement Cut ❑ .. Looped Fire Line ❑ .. Grease Interceptor ❑ .. Channelization ❑ .. Trench Excavation ❑ .. Utility Undergrounding WO # WO # WO # ❑...Deduct Water Meter Size Private ❑ Private ❑ FINANCE INFORMATION Fire Line Size at Property Line Number of Public Fire Hydrant(s) ❑ ...Water ❑ ...Sewer ❑ ...Sewage Treatment Monthly Service Billing to: Name: Day Telephone: Mailing Address: Water Meter Refund/Billing: Name: Mailing Address: City State Zip Day Telephone: City State Zip H:Applications\Forms-Applications On Line\201 I Applications\Permit Application Revised - 8-9-1 I.docx Revised: August 2011 bh Page 3 of 4 PERMIT APPLICATION NOTES — Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWN. Signature: AU;11)1 Print Name: Clark Miller Mailing Address: 9404 E Marginal Way S H:Wpplications\Forms-Applications On Line \20I I Applications\Pcrmit Application Revised - 8-9-1 I.docx Revised: August 2011 bh Date: Day Telephone: (206) 768-7149 Seattle WA 98108 City State Zip Page 4 of 4 o 4.4JILA h%s,. y J / 290).: Cash Register Receipt City of Tukwila Receipt Number R9233 DESCRIPTIONS ACCOUNT QUANTITY PAID PermitTRAK $2,142.79 D16-0235 Address: 9404 E MARGINAL WAY S Apn: 3324049019 $2,142.79 DEVELOPMENT $2,142.79 PLAN CHECK FEE TOTAL FEES PAID BY RECEIPT: R9233 R000.345.830.00.00 0.00 $2,142.79 $2,142.79 Date Paid: Friday, August 19, 2016 Paid By: THE MUSEUM OF FLIGHT Pay Method: CHECK 88644 Printed: Friday, August 19, 2016 10:33 AM 1 of 1 CPSYSTEMS Cash Register Receipt City of Tukwila DESCRIPTIONS I ACCOUNT I QUANTITY I PermitTRAK PAID $3,465.93 D16-0235 Address: 9404 E MARGINAL WAY S Apn: 3324049019 $3,465.93 DEVELOPMENT $3,301.10 PERMIT FEE R000.322.100.00.00 0.00 $3,296.60 WASHINGTON STATE SURCHARGE 8640.237.114 0.00 $4.50 TECHNOLOGY FEE $164.83 TECHNOLOGY FEE TOTAL FEES PAID BY RECEIPT: R9455 R000.322.900.04.00 0.00 $164.83 $3,465.93 Date Paid: Tuesday, September 20, 2016 Paid By: THE MUSEUM OF FLIGHT Pay Method: CHECK 88932 Printed: Tuesday, September 20, 2016 2:19 PM 1 of 1 CRWYSTEMS INSPECTION RECORD Retain a copy with permit INSPEC NO. oZ,3S PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project: rnuswit/I (771"? 641+r T e of Inspection: UPLbi,J& & AiAL Ajdress: 9 04 (/14/10.44AML 1J19 S Date Called: Special Instructions: Date Wanted:' / 2/24/16 a.m. = Requester: �77— Phone No: `j rg 2o& -7!t- 6 (1 EAApproved per applicable codes. LJ Corrections required prior to approval. COMMENTS: Inspector: A Date: 22-g4 REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit PECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 1)16..-0Z3s' Project: rf')10E))M i- o ) 6� - Type of Inspection: L,i*m4 61 PLEjl Actdress: 92/41q , 44 Oldift- l Date Called: 5 ecial I tractions: p (��,�I'' ( Lo irk t d6tp^ Date Wanted: /2 2 %G a.r p.m. Requester: Phone No: ElApproved per applicable codes. Corrections required prior to approval. COMMENTS: Inspector: Dat 2— REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. .M INSPECTION RECORD Retain a copy with permit L1SPECTON NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350La., Gy�S,,�, Project: Lj fim m= ,�7.ei-tr Type of Inspection: c i Address: 94/0. E' /11A126 -104-t- wY S Date Called: Special Instru iions: �j 57- .(q =-4�� ,p� c� Date Want : z0.6 a.m p.m. Request r: Phone No: Approved per applicable codes. L,1 Corrections required prior to approval. COMMENTS: Inspector: Date// _ 2q -t6 REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Kci INSPECTION RECORD Retain a copy with permit PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project: irU U il4 6) t )6,/-1-1-- Type o spection: /'l W iAZ- A ds: res .voq t AIS-lAiAl- CAti S Date Called: Special fnstructians lw� Date Wanted ��Z3�pm.fre0�� a.m.0/� equester Phone No: Approved per applicable codes. Corrections required prior to approval. COMMENTS: 7/'c Inspector: Date://,23 REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. rpm!INSPECTION RECORD Retain a copy with permit TION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Projecet,i_ , C?� �('(p 4f_ Type of Inspection: rr o / 1 � d� A re s: C-5r0Z I Date Called:,_r J tr/v.ate Sple c I In tructions: ®, �,.( rg.i / nted• *1. 166• Requester: Phone No: ElApproved per applicable codes. Corrections required prior to approval. COMMENTS: BLccsPnl r�aJr �L 57�i-dav��4 e 4 r -'6 - Inspector: Date:/ lc REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION %j 6300 Southcenter Blvd., #100, Tukwila. WA 9818872 Permit Inspection Request Line (206) 438-9350 1j16 -o ZSS Project: uS6.414 ar k; 614--r- Typ- of Inspection I t • '-' _141 Address: 91/oil EGi'AL (,WV S Date Called: Wanted- • r®/'/ /4''0° p.m. Special Instructions: jDate �J r-0' - 10( f' A fret -40%e_ Requester: - SCO! TT Phone No: 29-v9-6S"3q EiApproved per applicable codes. Corrections required prior to approval. COMMENTS: Inspector: Dates , z REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit b -az3 S" PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project: !/1o 11 iCioii Typpeof Inspection: l)N•CleC G SLA g Address: Wall (' grim,•.. w3V$ Date Called: Special I structions: et44, eo-S/Oe Date Wanted: /0 / m. p.m. Requester` f@ 6'41 6)4456/ Phone No: 206 -7/5- 6r?q Approved per applicable codes. Ll Corrections required prior to approval. COMMENTS: Inspector: Date/0 -I 7 -i REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. Y17161 e_ ati{? d 2- - ./v6 _ use Biq SP14 3 INSPECTION NUMBER INSPECTION RECORD Retain a copy with permit DI Q —C)? -3C 1(— S -- Y v PERMIT NUMBERS CITY OF TUKWILA FIRE DEPARTMENT 206-575-4407 Project:` 77 Type of Inspection; Address: Suite #: g yQ y CAJ 5 Contact Person: Special Instructions: Occupancy Type: Phone No.: XrApproved per applicable codes. Corrections required prior to approval. COMMENTS: ,gyp ---. Ar4s 11.7;1 kis , ti /1-/4/%w7 Needs Shift Inspection: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: Inspector: - % / Date: /0„..-3// 4 Hrs.: / • v /$100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. Billing Address Attn: Company Name: Address: City: State: Zip: Word/Inspection Record Form.Doc 3/14/14 T.F.D. Form F.P. 113 INSPECTION NUMBER INSPECTION RECORD Retain a copy with permit PERMIT NUMBERS CITY OF TUKWILA FIRE DEPARTMENT 206-575-4407 Pro)•qct: 'F 0 12-6---37-r2-66--vvt Type of Inspection: Fi44e-12 - 6-t 6H ri. Aii5 Address: A A Suite #: pi - 0 4- 6---- fro LA) S Contact Per,,sen: ` > . 6- o 17 -- Special Instructions: Phone No.: Approved per applicable codes. .EPI -Corrections required prior to approval. COMMENTS: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: F144 q- & ( 67 fLO-I f\/67 /A1Sy r -F/‘ / 6-1"-17— Ai& e - 6 7-0 /(-/ D 0 /27 6fi 6-- z 1 6? I__-( 7 ov 6? 7--4, 6:thi 2 E- 5 (D417_( Alt --Fl 7 F-7 6 D 4 -r- 771-- C-Goe2 Needs Shift Inspection: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: Inspector: ri/vi 54, 16--- rg Date: t 2 /2/ //6 Hrs.: it $100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. Billing Address Attn: Company Name: Address: City: State: Zip: Word/Inspection Record Form.Doc 3/14/14 T.F.D. Form F.P. 113 INSPECTION NUMBER INSPECTION RECORD Retain a copy with permit 0/6 ! (? r S O PERMIT NUMBERS CITY OF TUKWILA FIRE DEPARTMENT 206-575-4407 Project: �� 72M� . �o� ' Type of Inspectian: 74 , se "& Address:Contact Suite #: 9404/K 0_,S Person: Monitor: Special Instructions: Phone No.: Occupancy Type: „Approved per applicable codes. Corrections required prior to approval. COMMENTS: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: r fV- XWAIN/eb //( /UOT7. civil/ /4/1/e„,r//0 ,VG/ 5 /.J 2-'"0P - ,Z9 &.,,Y2,0 55 /Nkt&-Yz- r,-‘49 , 'f e Needs Shift Inspection: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: Inspector: l -Z Date: and b(� Hrs.: $100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. Billing Address Attn: Company Name: Address: City: State: Zip: Word/Inspection Record Form.Doc 3/14/14 T.F.D. Form F.P. 113 r INSPECTION NUMBER INSPECTION RECORD Retain a copy with permit )IGS -0z ss- /h - PERMIT NUMBERS CITY OF TUKWILA FIRE DEPARTMENT 206-575-4407 Project: tie o1 (,. r6/6„f(� Type of Inspection: r vi�� 1.r 5 n Address:(-1Contact Suite #: l�04- e v4 kv_ Person: Special Instructions: Phone No.: jiApproved per applicable codes. Corrections required prior to approval. COMMENTS: dl(-- co✓e I Needs Shift Inspection: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: Inspector: Fin ca. -1/4-Q-) Date:`stvlal, Hrs.: $100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. Billing Address Attn: Company Name: Address: City: State: Zip: Word/Inspection Record Form.Doc 3/14/14 T.F.D. Form F.P. 113 City of Tukwila Allan Ekberg, Mayor Public Works Department - Bob Giberson, Director August 26, 2016 Museum of Flight Foundation 489999 9404 East Marginal Way S Seattle, WA 98108 Attn: Clark Miller RE: Museum of Flight Tenant Improvement 9404 East Marginal Way S Permit No. D16-0235 To Whom It May Concern: In accordance with Washington State Department of Health guidelines for Group A Public Water Systems, Public Works has implemented a cross -connection control program to protect the public water system from contamination via cross -connection. The program requires elimination or control of any cross -connection between the distribution system and a consumer's water system by the installation of an approved backflow device. The subject building has all necessary backflow preventers installed; however, they are overdue for mandatory annual testing. All backflow assemblies were due June 2016. Contact Todd Reedy, Water Quality Specialist, directly at (206) 431-2169 for the list of overdue backflows. The Public Works Director will withhold issuance of the Museum of Flight Tenant Improvement permit until the Permit Center receives test reports for the above backflows. Please contact me at (206) 431-2440 or via email at joanna.spencer@tukwilawa.gov if you have any questions. Sincerely, Janna Spencer Development Engineer cc: D16-0235 File Pia Westen, Applicant (W:PW Eng/Other/Joanna Spencer/Letter Museum of Flight 082616) FILE COPY 6300 Building 0 6300 Southcenter Boulevard Suite 100 0 Tukwila, WA 98188 0 206-433-0179 Tukwila City Hall • 6200 Southcenter Boulevard • Tukwila, WA 98188 • 206-433-1800 • Website: TukwilaWA.gov Joanna Spencer From: Todd Reedy Sent: Monday, August 29, 2016 3:50 PM To: Joanna Spencer Subject: RE: D16-0235.9404 E MARGINAL WAY S Hi Joanna, We have now received completed backflow test reports for all of the backflow preventers at the Museum of Flight for the 2016 annual testing. They forwarded them to me today. Thank you, Todd From: Joanna Spencer Sent: Friday, August 26, 2016 4:07 PM To:'PIAW@SHKSARCHITECTS.COM' <PIAW@SHKSARCHITECTS.COM> Cc: Todd Reedy <Todd.Reedy@TukwilaWA.gov>; Joanna Spencer <Joanna.Spencer@TukwilaWA.gov> Subject: D16-0235 9404 E MARGINAL WAY S FYI, This letter will be mailed on Monday, August 29, 2016. Joanna Spencer Development Engineer Public Works Department 6300 Southcenter Blvd, Suite 100, Tukwila, WA 98188-2544 Phone: 206 431-2440 Fax: 206 431-3665 1 DIO235 PERMIT COORD COPY PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: D16-0235 DATE: 08/22/16 PROJECT NAME: MUSEUM OF FLIGHT SITE ADDRESS: 9404 E MARGINAL WAY S X Original Plan Submittal Revision # before Permit Issued Response to Correction Letter # Revision # after Permit Issued DEPARTMENTS: v S•' •1G Builkling Division RI J3S PA, 6• 40 Public Works A'it)c' 6•3c.(b Fire Prevention 151 Planning Division e/k 111A.8.2y•►� r11111 Structural Permit Coordinator n PRELIMINARY REVIEW: Not Applicable ❑ (no approval/review required) DATE: 08/23/16 Structural Review Required REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: DUE DATE: 09/20/16 Approved Approved with Conditions Corrections Required Ti Denied ❑ (corrections entered in Reviews) Notation: (ie: Zoning Issues) REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire 0 Ping ❑ PW ❑ Staff Initials: 12/18/2013 BNBUILDERS INC Washington State Department of Labor & Industries Home Espanol Contact Safety & Health Claims & Insurance Search L&I Page 1 of 4 A -Z Index Help My L&I Workplace Rights Trades & Licensing BNBUILDERS INC Owner or tradesperson Principals BASTIAN, BRADLEY JAMES, PRESIDENT NIELSEN, JEFFREY J, VICE PRESIDENT O'BRIEN, TIMOTHY D, CHIEF FINANCIAL OFFICER Doing business as BNBUILDERS INC WA UBI No. 602 056 687 2601 4TH AVE STE 350 SEATTLE, WA 98121 206-382-3443 KING County Business type Corporation Governing persons BRADLEY JAMES BASTIAN JEFFREY J NIELSEN; License Verify the contractor's active registration / license / certification (depending on trade) and any past violations. Construction Contractor License specialties GENERAL License no. BNBUII*990K3 Effective — expiration 05/23/2001— 09/12/2017 Bond _..._........ SAFECO INS CO OF AMERICA Bond account no. 6642084 Active. Meets current requirements. $12,000.00 Received by L&I Effective date 06/05/2009 06/02/2009 Expiration date Until Canceled Insurance Greenwich Insurance Company $1,000,000.00 Policy no. CGG740912004 Received by L&I Effective date 09/01/2016 09/07/2016 Expiration date 09/07/2017 Help us improve https://secure.lni.wa.gov/verify/Detail.aspx?UBI=602056687&LIC=BNBUII*990K3&SAW= 09/20/2016 M F FL HT RE TR M EXPAN N SHKSARCHITECTS ABBREVIATIONS L @ 0 (E) q. A.B. MW AC ACT ACU ADJ AFF ALT ALUM APPROX BLDG BLW B.O. CB CBB CEM CJ CL CLG CLR CO COL CONC GOND CONT CPT CT DBL DEMO DF WA DIFF DIM DISP DN DR OS DTL OW E EA ECS EF EJ EL ELEC ELEV EMERG EQ EXP FOP FD FE FF FH FIN FLR F.O. FOIL F010 FR FS AND ANGLE AT DIAMETER POUND OR NUMBER EXISTING CENTERLINE ANCHOR BOLT ABOVE AIR CONDITIONING ACOUSTIC CEILING TILE AIR CONDITION UNIT ADJUSTABLE ABOVE FINISHED FLOOR ALTERNATE ALUMINUM APPROXIMATELY BUILDING BELOW BOTTOM OF CATCH BASIN CEMENT BACKER BOARD CEMENT CONTROL JOINT CENTERLINE CEILING CLEAR CLEAN OUT COLUMN CONCRETE CONDITION CONTINUOUS CARPET CERAMIC TILE DOUBLE DEMOLISH DRINKING FOUNTAIN DIAMETER DIFFUSER DIMENSION DISPENSER DOWN DOOR DOWNSPOUT DETAIL DISHWASHER EAST EACH EXTERIOR COMPOSITE SIDING EXHAUST FAN EXPANSION JOINT ELEVATION ELECTRICAL ELEVATOR EMERGENCY EQUAL EXPANSION FIBER BOARD PANEL FLOOR DRAIN FIRE EXTINGUISHER FINISH FLOOR FIRE HYDRANT FINISH FLOOR FACE OF FURNISHED BY OWNER, INSTALL BY CONTRACTOR FURNISHED BY OWNER INSTALL BY OWNER FIRE RESISTANT FLOOR SINK MATERIAL SYMBOLS III'lIIIII -(II II 8/19/2016 8:17:07 AM BATT INSULATION EARTH MASONRY GA GALV GB GL GLB GND GR GRID GWB HB HC HCMU HDWD HDWE HT HM HR HORIZ I.D. INSUL INT JAN JT KIT LAB LAM LAV LKR LOC LT LVL M MAIL MAX MC MECH MEMO MFR MIN MIR MISC MH MO MTD MTL MULL N NA NIC NOM NTS NR OA OBS O.C. 0.0. OFF OPNG OPP PC PL PLAS PLY P.LAM PNT POC PR PSL PT PTN )n)0On,- �#u�n1uw �uu�nn� �iuu� IhihAk040 Ok0 LVAANAA u�.00 AO AAO GAUGE GALVANIZED GRAB BAR GLASS GLU-LAM BEAM GROUND GRADE GROUTED GYPSUM WALL BOARD HOSE BIBB HANDICAP HOLLOW CLAY MASONRY UNIT HARDWOOD HARDWARE HEIGHT HOLLOW METAL HOUR HORIZONTAL INSIDE DIAMETER INSULATION INTERIOR JANITOR JOINT KITCHEN LABORATORY LAMINATE LAVATORY LOCKER LOCATE LIGHT LAMINATED VENEER LUMBER MEN'S MATERIAL MAXIMUM MEDICINE CABINET MECHANICAL MEMBRANE MANUFACTURER MINIMUM MIRROR MISCELLANEOUS MANHOLE MASONRY OPENING MOUNTED METAL MULLION NORTH NOT APPLICABLE NOT IN CONTRACT NOMINAL NOT TO SCALE NOT RATED OVERALL OBSCURE ON CENTER OUTSIDE DIAMETER OFFICE OPENING OPPOSITE PRECAST CONCRETE PLATE PLASTER PLYWOOD PLASTIC LAMINATE PAINT POINT OF CONNECTION PAIR PARALLEL STRAND LUMBER PRESSURE TREATED PARTITION CONCRETE GRAVEL PLYWOOD QT R or RAD RB RCP RD REF REFR REINF RELOC REQ'D RES RM RO RV RL SA SC SCHED SECT SG SHT SIM SPEC SQ S.S. STA STD STL STH STOR STRUCT SOG SUSP SYM T, TMP T&G TEL TER THK T.O. TS TV TYP UL UNO VCT VERT VEST VIF VTR W W/ WC WD WF W/O WOM WM WP WSCT WT • • QUARRY TILE RADIUS RESILIENT BASE REFLECTED CEILING PLAN ROOF DRAIN REFERENCE REFRIGERATOR REINFORCED RELOCATE REQUIRED RESILIENT ROOM ROUGH OPENING ROOF VENT RAIN WATER LEADER SOUTH SMOKE ALARM SOLID CORE SCHEDULE SECTION SAFETY GLASS SHEET SIMILAR SPECIFICATION SQUARE STAINLESS STEEL STATION STANDARD STEEL STAIN STORAGE STRUCTURE SLAB ON GRADE SUSPENDED SYMMETRICAL TEMPERED TONGUE & GROOVE TELEPHONE TERRAllO THICK TOP OF TUBE STEEL TELEVISION TYPICAL UNDERWRITERS' LABORATORIES UNLESS NOTED OTHERWISE VINYL COMPOSITION TILE VERTICAL VESTIBULE VERIFY IN FIELD VENT THRU ROOF WEST WITH WATER CLOSET WOOD WIDE FLANGE WITHOUT WALK OFF MAT WOMEN'S WATERPROOFING WAINSCOT WEIGHT RIGID INSULATION WOOD STEEL DRAFTING SYMBOLS ROOM NAME 101 1i NAME A. ELEVATION XXX T.O. XXX - XX X O DESCRIPTION WALL SECTION BLDG SECTION EXTERIOR ELEVATION INTERIOR ELEVATION DETAIL NORTH ARROW GRID HEAD ROOM TAG WINDOW TAG WALL TAG DOOR TAG KEY NOTE ELEVATION NOTE SPOT ELEVATION CENTERLINE PROPERTY LINE FLOOR TRANSITION REVISION BREAKLINE DIMENSION POINT DETAIL BORDER GENERAL NOTES 1. MATERIALS, ASSEMBLIES AND NOTED ITEMS ARE NEW UNLESS OTHERWISE NOTED. 2. CONTRACTOR SHALL VERIFY CONDITIONS. NOTIFY THE ARCHITECT OF ANY CONDITIONS INCONSISTENT WITH THE INTENT OF THE DRAWINGS PRIOR TO STARTING OR CONTINUING WORK IN THE AREA CONCERNED. CODE: 1. ALL WORK SHALL CONFORM TO APPLICABLE CODES AND LOCAL BUILDING REQUIREMENTS, WHICH INCLUDE THE MOST CURRENT EDITIONS OF THE INTERNATIONAL BUILDING CODE WITH LOCAL AMENDMENTS, INTERNATIONAL MECHANICAL CODE (IMC), NATIONAL ELECTRICAL CODE (NEC), INTERNATIONAL FIRE CODE (IFC), AND WASHINGTON STATE ENERGY CODE (WEC). 2. MECHANICAL, ELECTRICAL AND PLUMBING PERMITS TO BE APPLIED FOR UNDER SEPARATE APPLICATION BY CONTRACTOR. K3. PROVIDE FIREBLOCKS AND DRAFTSTOPS PER IBC. 4. PROVIDE CLOSURE MEETING THE REQUIREMENT OF GOVERNING FIRE AUTHORITIES BETWEEN FIRE RATED FLOORS, SHAFTS AND BUILDING PARTITIONS AND PENETRATING DUCTS, PIPES, CONDUIT, MECHANICAL, ELECTRICAL, AND OTHER ITEMS. 5. RECESSES LOCATED WITHIN FIRE RATED PARTITIONS SH4LL BE CONSTRUCTED TO MAINTAIN THE REQUIRED FIRE RATING OF THE PARTITION. 6. PROTECT EXISTING FIRE EXTINGUISHERS AND CABINETS (RECESSED OR SURFACE MOUNTED) FROM DAMAGE. HAZMAT: 1. HAZARDOUS MATERIAL REMOVAL & DISPOSAL: BEFORE BEGINNING ANY DEMOLITION OR OTHER WORK, COMPLY WITH DOCUMENTS PREPARED BY THE OWNER'S HAZARDOUS MATERIALS CONSULTANT. THIS APPLIES TO DEMOLITION, DISPOSAL AND CONSTRUCTION OPERATIONS ASSOCIATED WITH THE PROJECT. THE CONTRACTOR WILL SUSPEND WORK IMMEDIATELY AND NOTIFY THE OWNER IF MATERIALS SUSPECTED OF BEING HAZARDOUS, AND NOT PREVIOUSLY IDENTIFIED, ARE ENCOUNTERED IN THE COURSE OF THE CONTRACTOR'S WORK. DEMOLITION: 1. WHERE ITEMS ARE INDICATED ON PLANS TO BE REMOVED, IT SHALL MEAN THE COMPLETE REMOVAL AND DISPOSAL OF THE ITEM INDICATED UNLESS OTHERWISE NOTED. CONTRACTOR IS RESPONSIBLE FOR REVIEW OF THE HAZARDOUS MATERIALS ABATEMENT AND ARCHITECTURAL DRAWINGS AND SPECIFICATIONS FOR CUTTING AND PATCHING WORK. DIMENSIONS: 1. DO NOT SCALE DRAWINGS. 2. VERIFY DIMENSIONS SHOWN ON DRAWINGS. USE ONLY DIMENSIONS INDICATED. PRIOR TO STARTING OR CONTINUING WORK, NOTIFY ARCHITECT OF DISCREPANCIES OR CONDITIONS INCONSISTENT WITH THE INTENT OF THE CONSTRUCTION DOCUMENTS. 3. DIMENSIONS ARE TO FACE OF CONCRETE, FACE OF MASONRY, OR FACE OF STUD, UNLESS OTHERWISE NOTED. 4. FINISHED SURFACE OF INFILL OR EXTENSIONS OF EXISTING PARTITIONS SHALL ALIGN WITH ADJACENT EXISTING SURFACES UNLESS OTHERWISE NOTED. 5. VERTICAL DIMENSIONS ARE MEASURED FROM STRUCTURAL SLAB, TOP OF STEEL OR TOP OF SHEATHING, UNLESS NOTED OTHERWISE. 6. DOORS NOT LOCATED BY DIMENSION ON PLANS SHALL 8E SIX INCHES FROM FACE OF ADJOINING PARTITION TO HINGE EDGE OF DOOR OPENING. PROVIDE MINIMUM 18" CLEAR FROM FACE OF ADJOINING PARTITION OR OTHER OBSTRUCTION TO JAMB EDGE OF DOOR OPENING, UNLESS OTHERWISE NOTED. NOTIFY ARCHITECT IF REQUIRED CLEARANCES ARE NOT AVAILABLE. COORDINATION: 1. COORDINATE ALL OPERATIONS WITH OWNER, SUCH AS AREAS USED FOR MATERIAL STORAGE, ACCESS TO AND FROM THE SITE, TIMING OF WORK AND REQUIREMENTS OF NOISE ORDINANCE. INSTALL DUST AND NOISE BARRIERS AS REQUIRED TO PROTECT EXISTING ADJACENT BUILDINGS AND OCCUPANTS AND TO MAINTAIN AN ENVIRONMENT SUITABLE TO PERMIT CONTINUED OCCUPANCY OF SUBJECT AND ADJACENT BUILDINGS. 2. REVIEW DEMOLITION DRAWINGS. PATCH AND REPAIR ALL EXISTING SURFACES AFFECTED BY DEMOLITION WORK. 3. VERIFY LOCATIONS OF EXISTING UTILITIES. CAP, MARK AND PROTECT AS NECESSARY TO COMPLETE THE WORK. 4. COORDINATE AND PROVIDE REQUIRED PENETRATIONS AND PATCHING WITH INDIVIDUAL SUBCONTRACTORS TO SUIT NEW WORK. 5. CONTRACTOR TO OBTAIN AND VERIFY ROUGH -IN DIMENSION REQUIREMENTS FOR CABINETRY, EQUIPMENT, ACCESSORIES AND THE LIKE INCLUDING THOSE DESIGNATED FOIC AND FOTO. CONTRACTOR TO PROVIDE BACKING, BLOCKING, SUPPORT AS REQUIRED FOR INSTALLATION. CONTRACTOR TO COORDINATE POWER, DATA, COMMUNICATIONS AND SECURITY REQUIREMENTS FOR FOIC AND FOTO EQUIPMENT WHERE SERVICES ARE REQUIRED. INCLUDE STUB OUTS AND CONNECTIONS. VERIFY AND COORDINATE DIMENSIONS OF FOIC AND FOTO ITEMS PRIOR TO PROCEEDING WITH WORK. INCLUDE STUB OUTS FOR FUTURE WORK. 6. PIPING, CONDUITS, DUCTS, ETC. SHALL BE CONCEALED IN WALLS, CHASES, ABOVE SUSPENDED CEILINGS, BELOW FLOORS OR BE FURRED -IN IN ROOMS WITH EXISTING CEILINGS, UNLESS OTHERWISE NOTED. DO NOT CONCEAL PIPING, CONDUITS, DUCTS, ETC. IN ELECTRICAL, MECHANICAL, AND COMMUNICATION ROOMS. 7. CAREFULLY COORDINATE MECHANICAL, ELECTRICAL, AND BUILDING SYSTEM INSTALLATIONS WITH EXISTING STRUCTURE AND BUILDING SYSTEMS. 8. "REMOVE" MEANS TO COMPLETELY AND PERMANENTLY REMOVE FROM THE PROJECT. 9. REFER TO LIGHTING PLAN AND ELECTRICAL DRAWINGS FOR ELECTRICAL DEVICES AND LOCATIONS. COORDINATE AND REVIEW DEVICE LOCATIONS WITH ARCHITECT IN FIELD PRIOR TO ROUGH -IN. REVISIONS No changes shall be made to the scope of work without prior approval of Tukwila Building Division. NOTE: Revisions will require a new plan submittal and may include additional plan review fees. 9404 EAST J 3 MARGINAL WAY S Penile South VICINITY MAP PROJECT INFORMATION PROJECT OWNER: MUSEUM OF FLIGHT PROJECT MANAGER: CLARK MILLER ADDRESS: 9404 EAST MARGINAL WAY S SEATTLE, WA 98108 SCOPE DESCRIPTION: PARTIAL FIRST FLOOR TENANT IMPROVEMENT CONSISTING OF PROPOSED RESTROOMS AND FIRST AID ROOM. APPLICABLE CODES: 2012 WASHINGTON STATE BUILDING CODE 2015 WASHINGTON STATE ENERGY CODE ZONING ANALYSIS 1. PROJECT ADDRESS: 9404 EAST MARGINAL WAY S SEATTLE, WA 98108 2. PARCEL NUMBER: 3324049019 3. LEGAL DESCRIPTION: THAT POR OF THE SE QTR OF SEC 33 TWP 24 N RNG 4 E WM IN KING COUNTY WA DESCRIBED AS FOLLOWS COMMENCING AT THE SE COR OF SD SUBD TH N 88-04-53 W A DIST OF 1314.13 FT ALG S LN THOF TO NELY MGN OF E MARGINAL WY S AND POB TH ALG SD MGN N 88-04-53 W A DIST OF 37.35 FT TH CONT ALG SD MGN N 22- 31-55 W A DIST OF 997.62 FT TH DEPARTING SD MGN S 87-49-39 E A DIST OF 77.07 FT TH N 22-49- 02 W A DIST OF 23.50 FT TH S 87-49-39 E A DIST OF 89.83 FT TH S 02-11- 39 W A DIST OF 42.19 FT TH S 88- 43-46 E A DIST OF 290.49 FT TH S-28- 43-46 E A DIST OF 89.25 FT TH S 88-18-47 E A DIST OF 164.78 FT TO A LN THAT IS 500 FT FR AND PLW C/L RUNWAY 13R -31L TH ALG SD LN S 28- 43-34 E A DIST OF 658.80 FT TH S 67-28-05 W DIST OF 596.64 FT TO POB PER CITY OF TUK BLA NO L 02-058 REC #20030115900002 4. LOT AREA: 498,510 SF 5. ZONE: MIC/H 6. CURRENT USE: MUSEUM 7. YEAR BUILT: 1987 8. ASSCOIATED PERMITS PLUMBING - UNDER SEPARATE PERMIT MECHANICAL - UNDER SPEARATE PERMIT ELECTRICAL - UNDER SPERATE PERMIT FIRE SPRINKLERS - UNDER SEPARATE PERMIT DESIGN TEAM ARCHITECT: SHKS ARCHITECTS 1050 NORTH 38TH ST SEATTLE, WA 98103 TEL: 206.675.9151 CONTACT: PIA WESTEN EMAIL: piaw@shksarchitects.com CONTRACTOR: BNBUILDERS 2601 4TH AVE, SUITE 350 SEATTLE, WA 98121 TEL: 206.382.3443 CONTACT: RACHAEL BARESH EMAIL: rachael.baresh@bnbuilders.com SHEET INDEX A0.0 A0.1 A0.2 AD1.0 AD1.1 A2.1 A2.2 A3.0 A6.0 A6.2 A8.0 COVER SHEET SITE PLAN CODE ANALYSIS FIRST FLOOR DEMO PLAN FIRST FLOOR DEMO RCP FLOOR PLAN MEZZANINE PLAN EXTERIOR ELEVATIONS BASEMENT RCP FIRST FLOOR RCP INTERIOR DETAILS SEPARATE PERMIT REQUIRED FOR: I Mechanical I3 Electrical Itiflumbing tB Gas Spina City of Tukwila BUILDING DIVISION REVIEWED FOR CODE COMPLIANCE APPROVED SEEP 0 2 2016 City f Tu1(wila BUILDING DIVISION Plan review approval is subject to errors and omissions. Approval of construction documents does not authorize the violation of any adopted code or ordinance. Recoipt of approved Field C • : and • nditi • s . acknowledgod: By: CITY O E T U K W I L A . `51itZ5 Dateg,Zp(� RECEIVED ••..'.•••• City of Tukwila AUG 18 2016 BUILDING DIVISION PERMIT CENTER 1050 N.38th St. - Seattle, WA 98103 - PH: 206.675.9151 - www.shksarchitects.com MUSEUM OF FLIGHT RESTROOM EXPANSION PERMIT SET 9404 E MARGINAL WAY S - SEATTLE, WA 98108 Drawn by: Checked: Date: Scale: - Revisions: No. Date PW MI 08/19/16 As indicated Remarks COVER SHEET A0.0 • • I • i • • i • • L.. 8/19/2016 8:17:10 AM • I • • • • i • • I • SITE PLAN " = 40'-O" • • I • I • • • - 1 • • • • • • (E) MARGINAL WAY • - SHKSARCHITECTS AREA OF WORK • • • • •.11011111111111111111111111.•• •• (E) PARKING - NO CHANGE •• •• 0111111011111 •• •• ••• ▪ • •• _ •- •• • I • I • • • • • • • • • • • I • REVIEWED FOR CODE COMPLIANCE APPROVED SEP 0 2 2016 City of Tukwila BUILDING DIVISION GENERAL NOTES: 1. PARKING IS EXISTING. 2. LANDSCAPING IS EXISTING. 3. NO CHANGE IN OCCUPANCY PROJECT TRUE NORTH NORTH GROUP. RECEIVED CITY OF TUKWILA AUG 192016 PERMIT CENTER 023S 1050 N. 38th St. Seattle, WA 98103 - PH: 206.675.9151 — www.shksarchitects.com MUSEUM OF FLIGHT RESTROOM EXPANSION PERMIT SET 9404 E MARGINAL WAY S — SEATTLE, WA 98108 Drawn by: Checked: Date: Scale: — Revisions: No. Date PW MI 08/19/16 1" = 40'-0" Remarks SITE PLAN = A0.1 8/19/2016 8:17:14 AM FIRST FLOOR OCCUPANCY LOAD FACTOR TABULATION PER 2012 IBC AREA NAME USE & OCCUPANCY CLASSIFICATION OCCUPANCY LOAD FACTOR (FUNCTION OF SPACE PER TABLE 1004.1.1) S.F.PER PERSON AREA NSF/GSF AREA CALC OCCUPANTS ACTUAL OCCUPANTS COMMENTS STORAGE B Accessory Storage Areas, Mechanical Equipment Room 300 Gross 12 SF 1 1 THEATER A Assembly W/ Fixed Seats 0 See Section 1004.7 3325 SF 437 (E) OCCUPANT LOAD, NO CHANGE MEN'S RESTROOM B Business Areas 100 Gross 270 SF 3 3 WOMEN'S RESTROOM B Business Areas 100 Gross 320 SF 4 4 FAMILY ROOM B Business Areas 100 Gross 101 SF 2 2 FAMILY ROOM B Business Areas 100 Gross 80 SF 1 1 VESTIBULE B Business Areas 100 Gross 303 SF 4 4 CORRIDOR B Business Areas 100 Gross 362 SF 4 3 CORRIDOR B Business Areas 100 Gross 277 SF 3 3 FIRST AID B Business Areas 100 Gross 75 SF 1 1 FIRST FLOOR 5125 SF 23 459 FLOOR EXIT ACCESS TRAVEL DISTANCE LEVEL PATH NAME PATH LENGTH FIRST FLOOR Exit Path 1 511-21/16" BUILDING CODE 1. OCCUPANY CLASSIFICATION (SBC 302): NO CHANGE FROM EXISTING A - MUSEUM B - ADMINISTRATIVE AND BUSINESS AREAS 2. CONSTRUCTION TYPE: II -A, NO CHANGE FROM EXISTING. 3. NUMBER OF STORIES: NO CHANGE FROM EXISTING. 4. ALARM: (E) FIRE ALARM. 5. ALLOWABLE AREA CALCULATIONS (PER SBC 503 & 506.3): NO CHANGE TO EXISTING 8. REQUIRED MEANS OF EGRESS WIDTH PER SBC 1005.1 NO CHANGE TO EXISTING EGRESS. REDUCED EGRESS WIDTH AT THEATER ONLY. REQUIRED THEATER EGRESS WIDTH: PER IBC 1015.1.1 OCCUPANT LOADS BETWEEN 501 AND 1,000 REQUIRE THREE EXITS. (E) OCCUPANT LOAD = 441 WHICH IS LESS THAN 501 (2) EXITS REQUIRED (E) EXITS PROVIDED: 2 DISTRIBUTION OF EGRESS CAPACITY: PER 1005.5, LOSS OF ANY ONE MEANS OF EGRESS SHALL NOT REDUCE THE AVAILABLE CAPACITY TO LESS THAN 50% OF THE REQUIRED CAPACITY. (E) THEATER OCCUPANTS = 441 (E) 1/2 OF THEATER OCCUPANTS = 221 EGRESS STAIR WIDTH: .2", (FULLY SPRINKLERED) ALL OTHER EGRESS COMPONENT WIDTH: .15", (FULLY SPRINKLERED) WIDTH PROVIDED AT EXITS: (E) EAST THEATER EXIT: (E) WEST THEATER EXIT: 144" (221 x .15"= 33.15" REQUIRED) 64" (221 x .2" = 44.2" REQUIRED) 9. ACCESSIBLE MEANS OF EGRESS NO CHANGE FROM EXISTING 10. COMMON PATH OF EGRESS TRAVEL PER SBC 1014.3 75 FEET MAX 11. EXIT AND EXIT ACCESS DOORWAYS REQUIRED PER SBC 1015.1 NO CHANGE FROM EXISTING 12. DISTANCE BETWEEN EXITS PER SBC 1015.2.1 NO CHANGE FROM EXISTING FIGURE 602.5 DRINKING FOUNTAIN SPOUT '' 1'-4" -1'-6" I (A) WHEELCHAIR ACCESSIBLE WATER CLOSETS FIGURE 604.2 WATER CLOSET LOCATION 4'-6" MIN 1'-3" TO 3'-5'10 FIGURE 604.5.1 SIDE WALL GRAB BAR AT WATER CLOSETS ) M ADA CHAPTER 6 PLUMBING ELEMENTS 1/4" = 11-0" TRANSFER SIDE FIGURE 604.5.2 REAR WALL GRAB BAR AT WATER CLOSETS FIRE RATED ASSEMBLY LEGEND ® ® ® ® IMP OCCUPANCY TAG LEGEND OCCUPANCY MARK EXISTING OCCUPANCY DESIGNATION OCCUPANCY CLASSIFICATION AREA OF OCCUPANCY 1 HR RATED 2 FIR RATED COMMON PATH OF EGRESS TRAVEL: DISTANCE A PERSON HAS TO TRAVEL BEFORE THEY HAVE A CHOICE OF GOING IN 2 DIRECTIONS MIA C=1 C:ZZ1 MAX TRAVEL DISTANCE: 42=3 CEO et20 112920 EGRESS LEGEND: C17,173 Car3. C2:73 EGRESS LEGEND: FIGURE 604.7 DISPENSER OUTLET LOCATIONS COMMON PATH EXIT ACCESS TRAVEL DISTANCE PATH EXIT ACCESS DIAGONAL DEAD END CORRIDOR CO M 5'-0"MIN (A) ADULT WALL HUNG WATER CLOSET FIGURE 604.8.1.1-2 WHEELCHAIR ACCESSIBLE TOILET COMPARTMENT DOORS SHKSARCHITECTS THEATER 3325 SF VESTIBULE 303 SF FIRST AID CORRIDOR 277 SF FAMILY ROOM 101 SF MEN'S RESTROOM 270 SF ettsj4111. 1114 FAMILY ROOM 80 SF STORAGE WOMEN'S RESTROOM 320 SF CORRIDOR 362 SF FIRST FLOOR 1/8" = 1'-0" REVIEWED FOR CODE NCE APPROVED SEP 02 2016 (A) ELEVATION ADULT 6" MIN L I C (B) ELEVATION CHILDREN L� (C) PLAN Q; FIGURE 604.8.1.4 WHEELCHAIR ACCESSIBLE TOILET COMPARTMENT TOE CLEARANCE FIGURE 604.8.2 AMBULATORY ACCESSIBLE TOILET COMPARTMENT (A) WALL HUNG TYPE FIGURE 605.2 HEIGHT AND DEPTH OF URNIALS (A) HINGED DOOR FIGURE 404.2.3 CLEAR WIDTH OF DOORWAYS ADA CHAPTER 4 1/4" = 11-0" 4 1'-6"MIN FRONT APPRAOCH (FA) PULL SIDE 1 _. I i' .= I i 1 1 1 FRONT APPRAOCH (FA) PUSH SIDE 12" * *IF BOTH CLOSER AND LATCH ARE PROVIDED • Co M E I-3 2' -0" MIN I LATCH APPRAOCH (LA) PUSH SIDE 2'-0" J * 48" IF CLOSER IS PROVIDED ** 54" IF CLOSER IS PROVIDED FIGURE 404.2.4.1 MANEUVERING CLEARANCES AT MANUAL SWINGING DOORS AND GATES LATCH APPRAOCH (LA) PULL SIDE ity of Tukwila CsB BUILDING DIVISION (A) PULL SIDE FIGURE 404.2.4.3 MANEUVERING CLEARANCES AT RECESSED DOORS AND GATES OUTLET/SWITCH 4r' WORK SURFACES — O — CD VISIBLE ALARM —9—, SIGNS/ADA SYMBOLS SIGNALS, OPERATORS, AND SURFACE HEIGHTS 1/4" = 1'-0" D o Zzi MANUAL FIRE ALARM PULL LIGHT SWITCH AUTO DOOR OPERATOR Fo ELEC OUTLET FIRE @ FLOOR EXTINGUISHER CABINET 1050 N. 38th St. Seattle, WA 98103 — PH: 206.675.9151 - www.shksarchitects.com MUSEUM OF FLIGHT RESTROOM EXPANSION PERMIT SET 9404 E MARGINAL WAY S — SEATTLE, WA 98108 Drawn by: Checked: Date: Scale: — Revisions: No. Date RECEIVED _ CITY OF TUKWILA PERMIT CENTER— PW MI 08/19/16 As indicated Remarks — CODE ANALYSIS )ara A012 ���i 01)--Q0- -Q0- OD UP 7!1 (�1J CI OD CI El itt Lt UP NI CIL El - 00 CO OD qj LY SHKSARCHITECTS OD (2 c2) CO OD c12) OD 21) C2) \\\'\\,\\\'\\,: • REMOVE (E) WALL ASSEMBLY AS REQUIRED TO INSTALL PLUMBING FIRST FLOOR DEMO PLAN 1/4" = 1'-O" 8/19/2016 8:17:29 AM 55' -1 1/2" +/- 5' - 8" +/- 8' - 6 3/4" +/- 8' - 4" +/- REVIEWED FOR CODE COMPLIANCE APPROVED SEP 0 2 2016 City of Tukwila BUILDING DIVISION DEMO LEGEND: (E) WALL — REMOVE (E) WALL REMOVE (E) TILE FLOORING REMOVE (E) CARPET FLOORING KEYNOTE LEGEND MARK KEYNOTE TEXT D1 REMOVE (E) DOOR D4 REMOVE (E) WATER FOUNTAIN D5 REMOVE (E) COUNTERTOP D6 REMOVE (E) URINAL D7 REMOVE (E) TOILET D8 REMOVE (E) SINK D9 REMOVE (E) TOILER PARTITION D11 REMOVE (E) GWB, (E) FRAMING TO REMAIN 1050 N.38th St. - Seattle, WA 98103 - PH: 206.675.9151 - www.shksarchitects.com MUSEUM OF FLIGHT RESTROOM EXPANSION - PERMIT SET 9404 E MARGINAL WAY S — SEATTLE, WA 98108 Drawn by: Checked: Date: Scale: — Revisions: No. Date RECEIVED CITY OF TUKWILA- AUG 19 2016 PERMIT CENTER — PW MI 08/19/16 1/4" = 1'-0" Remarks - FIRST FLOOR I � 023 s•AD1= DEMO PL.0AN - SHKSARCHITECTS 8/19/2016 8:17:32 AM FIRST FLOOR DEMO RCP 1/4" = 1'-0" RCP DEMO LEGEND: REVIEWEDMLIANCE FOR CODE APPROVED SEP 0 2, 2M6 Bu1LDtCiti of ¶DIVukwUa NC ! REMOVE OR SALVAGE AS INDICATED BY KEYNOTE REMOVE (E) GWB CEILING KEYNOTE LEGEND MARK KEYNOTE TEXT D13 REMOVE (E) LIGHT FIXTURE D14 REMOVE (E) GLAZING PANEL AS REQUIRED PER MECH bi 1050 N.38th St. Seattle, WA 98103 - PH: 206.675.9151 - www.shksarchitects.com MUSEUM OF FLIGHT RESTROOM EXPANSION PERMIT SET 9404 E MARGINAL WAY S — SEATTLE, WA 98108 Drawn by: Checked: Date: Scale: — Revisions: No. Date RECEIVED CITY OF TUKWILA AUG 192016 PERMIT CENTER - PW MI 08/19/16 1/4" = 1'-0" Remarks FIRST FLOOR DEMO CP C = AD p �' 1 i1 1111 111I6111 1111 1111 El Kt IM 11111 111 111/1 1111 IN II CPT TO MATCH (E) CPT SHKSARCHITECTS MEN'S RESTROOM FAMILY ROOM FAMILY ROOM L 8/19/2016 8:17:17 AM FIRST FLOOR PLAN 1/4" = 1'-0" DOOR SCHEDULE MARK ROOM NAME SIZE DOOR FRAME/TRIM FIRE RATING REMARKS HW GROUP W H MATERIAL FINISH MATERIAL FINISH 101 FIRST AID 3' - 0" 7 - 0" HM PT HM PT 1 HR 102 FAMILY ROOM 3' - 0" 7' - 0" HM PT HM PT 1 HR 103 FAMILY ROOM 3' - 0" 7' - 0" HM PT HM PT 1 HR 104 CORRIDOR 3' - 0" 7' - 0" HM PT HM PT 1 HR 105 MEN'S RESTROOM 3' - 0" 7' - 0" NM PT HM PT 1 HR 106 WOMEN'S RESTROOM 3' - 0" 7' - 0" HM PT HM PT 1 HR 108 CLOSET 2' - 6" 7' - 0" WD PT WD PT NR REVIEWED FOR GODE�OMPLIANCE �, PROVED SEP 0 2 2016 City of Tukwila BUILDING DIVISION KEYNOTE LEGEND MARK KEYNOTE TEXT 2 LAVATORY 4 CHANGING STATION 7 BOTTLE FILLING STATION/DRINKING FOUNTAIN COMBO 9 COUNTERTOP GENERAL NOTES: 1. WALLS TO 6" ABOVE CEILING TYP UNO. 2. PROTECT (E) FIREPROOFING. 3. SEE 3/A3.0 FOR WALL TYPES PLAN LEGEND (E) WALL WALL I } COMBO WASTE RECEPTACLE CWP PAPER TOWEL DISPENSER I I PTD HD PAPER TOWEL DISPENSER HAND DRYER WASTE RECEPTACLE WR 0135 -___ A2.1 1050 N.38th St. Seattle, WA 98103 - PH: 206.675.9151 - www.shksarchitects.com MUSEUM OF FLIGHT RESTROOM EXPANSION PERMIT SET 9404 E MARGINAL WAY S — SEATTLE, WA 98108 Drawn by: Checked: Date: Scale: — Revisions: No. Date RECEIVED - CITY OF TUKWILA AUG 19 2016 - PERMIT CENTER PW MI 08/19/16 1/4" =1'-0" Remarks FLOOR PLAN MEZZANINE 1/4" =1'-0" 8/19/2016 8:17:19 AM 19' - 3" +/- 19' - 3" +/- 19' - 3" +/- 19'-3"+/- 19'-3"+/- 1 EQUIPMENT PER MECH I A3.0 a) N SHKSARCHITECTS GENERAL NOTES: 1. PROTECT (E) FIREPROOFING. 2. MECHANICAL AND RELATED WORK UNDER SEPARATE PERMIT. REVIEWED FOR CODE COMPLIANCE OMP IA CE APPROVED SEP p 2 2016 City of TuloNila BUILDING DIVISION l(r 35 1050 N.38th St. Seattle, WA 98103 - PH: 206.675.9151 - www.shksarchitects.com MUSEUM OF FLIGHT RESTROOM EXPANSION PERMIT SET 9404 E MARGINAL WAY S — SEATTLE, WA 98108 Drawn by: Checked: Date: Scale: — Revisions: No. Date RECEIVED _ CITY OF TUKWILA AUG 19 2016 - PERMIT CENTER PW MI 08/19/16 1/4" = 1'-0" Remarks - MEZZANINE PLAN = A2.2 EQUIPMENT PER MECHANCIAL GWB (E) CATWALK RESILIENT BASE 8/19/2016 8:17:23 AM CORRIDOR SECTION 1/4" = 1'-0" wawa SECOND FLOOR 4, 46'-0" CAT WALKS 4, 39'-6" MEZZANINE 46, 36'-0" FIRST FLOOR 4, 20' - 0" BASEMENT 4. 9'-0" 1'-6" 1A: SEE SPECIFICATION FOR PIPING AND ACOUSTIC REQUIREMENTS 0WALL TYPE LEGEND „_ " SHKSARCHITECTS GENERAL NOTES: 1. MECHANICAL AND RELATED WORK UNDER SEPARATE PERMIT. 2. PROTECT (E) FIREPROOFING. EAST ELEVATION 1/8" =1'-0" (2) LAYERS 5/8" TYPE "X" GWB 4" MTL STUD AT 16" 0.C. ACOUSTIC BATT INSULATION 4" MTL STUD AT 16" 0.C. 5/8" TYPE "X" GWB, BACKER BOARD AT TILE LOCATIONS PER ELEVATIONS 5/8" TYPE "X" GWB, BACKER BOARD AT TILE LOCATIONS PER ELEVATIONS 4" MTL STUD AT 16" 0.C. 5/8" TYPE "X" GWB 4" ACOUSTIC BATT INSULATION ACOUSTIC BATT INSULATION (E) FRAMING - — (E) GWB 2A: SEE SPECIFICATION FOR PIPING AND ACOUSTIC REQUIREMENTS LOUVER PER MECH, TYP 3A: t (2) LAYERS 5/8" TYPE "X" GWB 4" MTL STUD AT 16" O.C. 4" ACOUSTIC BATT INSULATION 5/8" TYPE "X" GWB 11' 5/8" TYPE "X" GWB, BACKER BOARD AT TILE LOCATIONS PER ELEVATIONS 4" MTL STUD AT 16" O.C. 4" ACOUSTIC BATT INSULATION 5/8" TYPE °X" GWB, BACKER BOARD AT TILE LOCATIONS PER ELEVATIONS 4A: 4B: OMIT 4" ACOUSTIC BATT INSULATION 5A: a OMIT 4" ACOUSTIC BATT INSULATION 2X4 MTL FRAMING AT 16" O.C. 5/8" TYPE "X" GWB, BACKER BOARD AT TILE LOCATIONS PER ELEVATIONS 4" MTL STUD AT 16" O.C., TYP 4" ACOUSTIC BATT INSULATION 5/8" TYPE "X" GWB (E) MTL STUD (2X MTL STUD AT 16" O.C. AT 5B) B.O. ROOF AI 55'-107/16" SECOND FLOOR ik 46'-0" CAT WALKS 39'-6" 7 MEZZANINE da 36'-0" PROJECTION 33'-0" Y FIRST FLOOR Aka 20'-0" REVIEWED FOR CODE COMPLIANCE APPROVED SEP 0 2 2016 City of Tukwila BUILDING DIVISION 6A: 5/8" TYPE "X" GWB 6" MTL STUD AT 16" O.C. 6" ACOUSTIC BATT INSULATION 5/8" TYPE "X" GWB 1050 N.38th St. Seattle, WA 98103 — PH: 206.675.9151 - www.shksarchitects.com MUSEUM OF FLIGHT RESTROOM EXPANSION PERMIT SET 9404 E MARGINAL WAY S — SEATTLE, WA 98108 Drawn by: Checked: Date: Scale: — Revisions: No. Date RECEIVED CITY OF TUKWILA _ AU6 1 8 2016 -- PERMIT PERMIT CENTER PW MI 08/19/16 As indicated Remarks EXTERIOR ELEVATIONS 1� BASEMENT 8/19/2016 8:28:16 AM MEN'S 0.21 FIRST AID SECURITY DARK ROOM 0.23 PLENUM 0.25 MECHANICAL 0.26 u LI WOMEN'S RESTROOM LOUNGE WOMEN'S PHOTO LAB ELEV MACH ELEVATOR STAIR STAIR 10 REPLACE ACOUSTIC TILE TO MATCH (E), SALVAGE AND REINSTALL (E) LIGHT FIXTURES, TYP REMOVE (E) GWB CEILING AS REQUIRED TO INSTALL PLUMBING PIPING. RESTORE TO MATCH (E) UPON COMPLETION 1/8" = 1'-0" CEILING TYPES: 1A: 5/8" TYPE "X" GWB 4" MTL STUD AT 16" OC 1 B: 5/8" TYPE "X" GWB 4" MTh STUD AT 16" OC 5/8" TYPE "X" GWB 1C: 5/8" TYPE "X" GWB (E) FRAMING 2A: 25(4' ACOUSTIC CEILING TILE TO MATCH (E) GRID RCP LEGEND LIGHTING SYMBOLS Q RECESSED CAN LIGHT �—I WALL MOUNTED FIXTURE LINEAR RECTANGULAR LIGHT FIXTURE RECTANGULAR PENDANT LIGHT FIXTURE SHKSARCHITECTS REVIEWED FOR CODE COMPLIANCE APPROVED SEP 0 2 2016 City of Tukwila BUILDING DIVISION 1050 N.38th St. Seattle, WA 98103 PH: 206.675.9151 www.shksarchitects.com MUSEUM OF FLIGHT RESTROOM EXPANSION PERMIT SET 9404 E MARGINAL WAY S SEATTLE, WA 98108 Drawn by: Checked: Date: Scale: — Revisions: No. Date RECEIVED - CITY OF TUKWILA AUG 192016 — PERMIT CENTER PW MI 08/19/16 As indicated Remarks BASEMENT RCP 1 FIRST FLOOR RCP 1/4" = 1'-0" 8/19/2016 8:28:17 AM REVIEWED FOR CODE COMPLIANCE APPROVED SEP 0 2 2616 Cid► ©G DIVISION SHKSARCHITECTS CEILING TYPES: 1 A: 5/8" TYPE "X° GWB 2X4MIL STUD AT16"OC 1 B: 5/8" TYPE "X" GWB 2x4MIL STUD AT16"OC 5/8" TYPE "X" GWB 1 C: 5/8" TYPE "X" GWB (E) FRAMING 2A: 21x4' ACOUSTIC CEILING TILE TO MATCH (E) GRID RCP LEGEND LIGHTING SYMBOLS 0 RECESSED CAN LIGHT WALL MOUNTED FIXTURE LINEAR RECTANGULAR LIGHT FIXTURE RECTANGULAR PENDANT LIGHT FIXTURE bl 1050 N.38th St. - Seattle, WA 98103 - PH: 206.675.9151 - www.shksarchitects.com MUSEUM OF FLIGHT RESTROOM EXPANSION PERMIT SET 9404 E MARGINAL WAY S - SEATTLE, WA 98108 Drawn by: Checked: Date: Scale: — Revisions: No. Date RECEIVED - CITY OF TUKWLLA AUG 19 2016 - PERMIT CENTER PW MI 08/19/16 = 1'-0" Remarks 1 FIRST FLOOR RCP 0413 S. = A6.2 07'-111/4"$ FAMILY ROOM 103 REVIEWED FOR CODE COMPLIANCE APPROVED SEP 0 2 2616 Cid► ©G DIVISION SHKSARCHITECTS CEILING TYPES: 1 A: 5/8" TYPE "X° GWB 2X4MIL STUD AT16"OC 1 B: 5/8" TYPE "X" GWB 2x4MIL STUD AT16"OC 5/8" TYPE "X" GWB 1 C: 5/8" TYPE "X" GWB (E) FRAMING 2A: 21x4' ACOUSTIC CEILING TILE TO MATCH (E) GRID RCP LEGEND LIGHTING SYMBOLS 0 RECESSED CAN LIGHT WALL MOUNTED FIXTURE LINEAR RECTANGULAR LIGHT FIXTURE RECTANGULAR PENDANT LIGHT FIXTURE bl 1050 N.38th St. - Seattle, WA 98103 - PH: 206.675.9151 - www.shksarchitects.com MUSEUM OF FLIGHT RESTROOM EXPANSION PERMIT SET 9404 E MARGINAL WAY S - SEATTLE, WA 98108 Drawn by: Checked: Date: Scale: — Revisions: No. Date RECEIVED - CITY OF TUKWLLA AUG 19 2016 - PERMIT CENTER PW MI 08/19/16 = 1'-0" Remarks 1 FIRST FLOOR RCP 0413 S. = A6.2 2'-0" I ACCESSIBLE SINK 8/19/2016 8:17:27 AM " = 1'-0" 8" MIN 11" MIN MIRROR COUNTER AND BACKSPLASH KNEE CLEARANCE PER ADA 306 INSULATE PIPES PER ADA 606 r 5/8" TYPE "X" GWB 5/8" TYPE "X" GWB CEILING PER PLAN WALL PER PLAN RATED WALL TO RATED CEILING 3° = 1'-0" 1 4" MIN (E) STRUCTURE EXPANSION ANCHORS TO CONCRETE, TYP MTL ANGLE / MTL NAILER 5/8" TYPE "X" GWB CEILING PER PLAN RATED CHASE WALL TO RATED CEILING 3" = 1'-0" WALL PER PLAN 5/8" TYPE "X° GWB // (2) 2x4 MTL BRACING 6' O.C. MAX ALTERNATE BRACE ORIENTATION WHERE POSSIBLE SHEET MTh SCREWS EACH END TYPICAL WALL BRACING 3° = 1'-0" WALL PER PLAN GWB, TYP WALL PER PLAN RESILIENT BASE, TYP SEALANT, TYP FLOORING PER PLAN, TYP (E) CONCRETE SHKSARCHITECTS REVIEWED FOR CODE COMPLIANCE APPROVED SEP p 2 2016 City of Tukwila BUILDING DIVISION 1050 N.38th St. Seattle, WA 98103 - PH: 206.675.91 51 - www.shksarchitects.com MUSEUM OF FLIGHT RESTROOM EXPANSION PERMIT SET 9404 E MARGINAL WAY S — SEATTLE, WA 98108 Drawn by: PW Checked: MI Date: 08/19/16 Scale: As indicated — Revisions: No. Date RECEIVED CITY OF TUKWttA AUG 1 9 2016 - PERMIT CENTE-R Remarks INTERIOR DETAILS bl�� (a3S. = A8.O