Loading...
HomeMy WebLinkAboutPermit D16-0238 - HOMEWOOD SUITES - LOBBY RENOVATIONHOMEWOOD SUITES 6955 FORT DENT WAY D16-0238 Parcel No: Address: City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-438-9350 Web site: http://www.TukwilaWA.gov DEVELOPMENT PERMIT 2954900460 Permit Number: D16-0238 6955 FORT DENT WAY BLDG 4 Issue Date: 10/28/2016 Permit Expires On: 4/26/2017 Project Name: HOMEWOOD SUITES TUKWILA Owner: Name: Address: Contact Person: Name: Address: Contractor: Name: Address: License No: Lender: Name: Address: APPLE EIGHT SPE TUKWILA INC 814 E MAIN ST, RICHMOND, OH, 23219 MIKE KEIFLING 311 ELM STREET, STE 600 , CINCINNATI, OH, 45202 Phone: (513) 659-1912 ZERR & ASSOCIATES INC Phone: 5650 E EVANS AVE SUITE 110, DENVER, CO, 80222 ZERRAAI914LK Expiration Date: APPLE HOSPITALITY REIT, INC 814 EAST MAIN ST, RICHMOND, VA, 23219 DESCRIPTION OF WORK: HOTEL LOBBY ISA SEPARATE BUILDING FROM THE GUESTROOM BUILDINGS. LOBBY RENOVATION IS INCLUSIVE OF OFFICE RECONFIGURATION AND NEW FINISHES AND EQUIPMENT. THE MEETING ROOM IN GUESTROOM BUILDING WILL HAVE NEW HVAC AND RECONFIGURE RESTROOMS TO BE ACCESSIBLE Project Valuation: $112,902.00 Type of Fire Protection: Sprinklers: YES Fire Alarm: Type of Construction: VB Electrical Service Provided by: TUKWILA Fees Collected: $2,762.08 Occupancy per IBC: R-1 Water District: TUKWILA Sewer District: TUKWILA Current Codes adopted by the City of Tukwila: International Building Code Edition: International Residential Code Edition: International Mechanical Code Edition: Uniform Plumbing Code Edition: International Fuel Gas Code: 2015 2015 2015 2015 2015 National Electrical Code: WA Cities Electrical Code: WAC 296-46B: WA State Energy Code: 2014 2014 2014 2015 Public Works Activities: Channelization/Striping: Curb Cut/Access/Sidewalk: Fire Loop Hydrant: Flood Control Zone: Hauling/Oversize Load: Land Altering: Landscape Irrigation: Sanitary Side Sewer: Sewer Main Extension: Storm Drainage: Street Use: Water Main Extension: Water Meter: Volumes: Cut: 0 Fill: 0 Number: 0 Permit Center Authorized Signature: Date: lOI2—' I hearby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this development permit and agree to the conditions attached to this permit. Signature: Print Name: Date: G This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 4: The total number of fire extinguishers required for a light hazard occupancy with Class A fire hazards is calculated at one extinguisher for each 3,000 sq. ft. of area. The extinguisher(s) should be of the "all purpose" (2A, 10 B:C) dry chemical type. The travel distance to any extinguisher must be 75' or less. (IFC 906.3) (NFPA 10, 5.4) 1: Portable fire extinguishers, not housed in cabinets, shall be installed on the hangers or brackets supplied. Hangers or brackets shall be securely anchored to the mounting surface in accordance with the manufacturer's installation instructions. Portable fire extinguishers having a gross weight not exceeding 40 pounds (18 kg) shall be installed so that its top is not more than 5 feet (1524 mm) above the floor. Hand- held portable fire extinguishers having a gross weight exceeding 40 pounds (18 kg) shall be installed so that its top is not more than 3.5 feet (1067 mm) above the floor. The clearance between the floor and the bottom of the installed hand-held extinguishers shall not be less than 4 inches (102 mm). (IFC 906.7 and IFC 906.9) 2: Extinguishers shall be located in conspicuous locations where they will be readily accessible and immediately available for use. These locations shall be along normal paths of travel, unless the fire code official determines that the hazard posed indicates the need for placement away from normal paths of travel. (IFC 906.5) 3: Fire extinguishers require monthly and yearly inspections. They must have a tag or label securely attached that indicates the month and year that the inspection was performed and shall identify the company or person performing the service. Every six years stored pressure extinguishers shall be emptied and subjected to the applicable recharge procedures. If the required monthly and yearly inspections of the fire extinguisher(s) are not accomplished or the inspection tag is not completed, a reputable fire extinguisher service company will be required to conduct these required surveys. (NFPA 10, 7.2, 7.3) • 5: Maintain fire extinguisher coverage throughout. 6: Egress doors shall be readily openable from the egress side without the use of a key or special knowledge or effort. (IFC 1008.1.8.3 subsection 2.2) 7: Dead bolts are not allowed on auxiliary exit doors unless the dead bolt is automatically retracted when the door handle is engaged from inside the tenant space. (IFC Chapter 10) 8: Exit hardware and marking shall meet the requirements of the International Fire Code. (IFC Chapter 10) 9: Door handles, pulls, latches, locks and other operating devices on doors required to be accessible by Chapter 11 of the International Building Code shall not require tight grasping, tight pinching or twisting of the wrist to operate. (IFC 1008.1.9.1) 10: Exits and exit access doors shall be marked by an approved exit sign readily visible from any direction of egress travel. Access to exits shall be marked by readily visible exit signs in cases where the exit or the path of egress travel is not immediately visible to the occupants. Exit sign placement shall be such that no point in an exit access corridor is more than 100 feet (30,480 mm) or the listed viewing distance for the sign, whichever is less, from the nearest visible exit sign. (IFC 1011.1) 11: Every exit sign and directional exit sign shall have plainly legible letters not less than 6 inches (152 mm) high with the principal strokes of the letters not less than 0.75 inch (19.1 mm) wide. The word "EXIT" shall have letters having a width not less than 2 inches (51 mm) wide except the letter "1", and the minimum spacing between letters shall not be less than 0.375 inch (9.5 mm). Signs larger than the minimum established in section 1011.5.1 of the International Fire Code shall have letter widths, strokes and spacing in proportion to their height. The word "EXIT" shall be in high contrast with the background and shall be clearly discernible when the exit sign illumination means is or is not energized. If an arrow is provided as part of the exit sign, the construction shall be such that the arrow direction cannot be readily changed. (IFC 1011.6) 12: Exit signs shall be illuminated at all times. To ensure continued illumination for a duration of not less than 90 minutes in case of primary power loss, the sign illumination means shall be connected to an emergency power system provided from storage batteries, unit equipment or on-site generator. (IFC 1011.6.3) 13: Emergency lighting facilities shall be arranged to provide initial illumination that is at least an average of 1 foot-candle (11 lux) and a minimum at any point of 0.1 foot-candle (1 lux) measured along the path of egress at floor level. Illumination levels shall be permitted to decline to 0.6 foot-candle (6 lux) average and a minimum at any point of 0.06 foot-candle (0.6 lux) at the end of the emergency lighting time duration. A maximum-to-minimum illumination uniformity ratio of 40 to 1 shall not be exceeded. (IFC 1006.3.1) `17: Fire protection systems shall be maintained in accordance with the original installation standards for that system. Required systems shall be extended, altered or augmented as necessary to maintain and continue protection whenever the building is altered, remodeled or added to. Alterations to fire protection systems shall be done in accordance with applicable standards. (IFC 901.4) 15: Sprinklers shall be installed under fixed obstructions over 4 feet (1.2 m) wide. (NFPA 13-8.6.5.3.3) 14: All new sprinkler systems and all modifications to existing sprinkler systems shall have fire department review and approval of drawings prior to installation or modification. New sprinkler systems and all modifications to sprinkler systems involving more than 50 heads shall have the written approval of Factory Mutual or any fire protection engineer licensed by the State of Washington and approved by the Fire Marshal prior to submittal to the Tukwila Fire Prevention Bureau. No sprinkler work shall commence without approved drawings. (City Ordinance No. 2436). 18: A fire alarm system is required for this project. The fire alarm system shall meet the requirements of N.F.P.A. 72 and City Ordinance #2437. 20: Maintain fire alarm system audible/visual notification. Addition/relocation of walls or partitions may require relocation and/or addition of audible/visual notification devices. (City Ordinance #2437) 19: All new fire alarm systems or modifications to existing systems shall have the written approval of The Tukwila Fire Prevention Bureau. No work shall commence until a fire department permit has been obtained. (City Ordinance #2437) (IFC 901.2) 21: An electrical permit from the City of Tukwila Building Department Permit Center (206-431-3670) is required for this project. 22: All electrical work and equipment shall conform strictly to the standards of the National Electrical Code. (NFPA 70) 23: The maximum flame spread class of finish materials used on interior walls and ceilings shall not exceed that set forth in Table No. 803.9 of the International Building Code. 16: Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (City Ordinances #2436 and #2437) 24: Any overlooked hazardous condition and/or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. 25: These plans were reviewed by Inspector 511. If you have any questions, please call Tukwila Fire Prevention Bureau at (206)575-4407. 26: ***BUILDING PERMIT CONDITIONS*** 27: Work shall be installed in accordance with the approved construction documents, and any changes made during construction that are not in accordance with the approved construction documents shall be resubmitted for approval. 28: All permits, inspection record card and approved construction documents shall be kept at the site of work and shall be open to inspection by the Building Inspector until final inspection approval is granted. 29: New suspended ceiling grid and light fixture installations shall meet the seismic design requirements for nonstructural components. ASCE 7, Chapter 13. 30: Partition walls shall not be tied to a suspended ceiling grid. All partitions greater than 6 feet in height shall be laterially braced to the building structure. Such bracing shall be independent of any ceiling splay bracing. 31: All construction shall be done in conformance with the Washington State Building Code and the Washington State Energy Code. 32: Notify the City of Tukwila Building Division prior to placing any concrete. This procedure is in addition to any requirements for special inspection. 33: All wood to remain in placed concrete shall be treated wood. 34: There shall be no occupancy of a building until final inspection has been completed and approved by Tukwila building inspector. No exception. 35: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of this requirement. 36: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206-431-3670). 37: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center. 38: Preparation before concrete placement: Water shall be removed from place of deposit before concrete is placed unless a tremie is to be used or unless otherwise permitted by the building official. All debris and ice shall be removed from spaces to be occupied by concrete. 39: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 40: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431-3670). 41: ***PUBLIC WORKS PERMIT CONDITIONS*** 42: Prior to issuance of this permit Owner/Representative shall sign a completed King County Non -Residential Sewer Use Certification. PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 1700 BUILDING FINAL** 0301 CONCRETE SLAB 1400 FIRE FINAL 0201 FOOTING 0409 FRAMING 0606 GLAZING LATH & GYPSUM 0401 ROOF SHEATHING 0406 SUSPENDED CEILING CITY OF TUKWILA Community Development Department Public Works Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http:'i\\ NA\.TLIk ilaWA.nom Building Permit No. Project No. Date Application Accepted: "V7 i f Date Application Expires: 11 (For oJice use on! CONSTRUCTION PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **Please Print** SITE LOCATION King Co Assessor's Tax No.: Z°IS4Q 0041 L 00 Site Address: (.D 5g RAT D'CP&V WA'?,TUW131LA R 1461Lb Suite Number: Floor: Tenant Name: 1. 00A.i )C,0' 4'41:e% -CV kJ...) ILA New Tenant: ❑ Yes J ..No PROPERTY OWNER Name: AiWE 1409;otrA TY RECC, 1 NL Address: , 6a5 f. A1u ;It5' 4-- City: .RICAAMAI Pal> State: /A Zip:23711 CONTACT PERSON - person receiving all project communication Company Name: .q� '!�`" Name: Ithlte.- i +.‘ e.. fe.C.l4- .tlQns . .7rr0 i'k ) i # Address311 s az Cr s 1.00 City: 0Oci bi,JA4T I State: 01.4 Zip:A Suit Phone:56. 4.5ci. let i Z Fax: 0006136/3 Email: Lap LIN. CAMM �c.�.l != 0t t -P t 1 n GENERAL CONTRACTOR INFORMATION Company Name: .q� '!�`" n •.4e-5 err k. t\ssot) Address: S6 5.0 fas f- .tlQns . .7rr0 i'k ) i City: �G�lat� State: ct7 Zip: $0ZZ2 Phone: 303 _ 751.7776 Fax: 305.75$ -?770 ,ontr Reg No.: .tcce,_ _ p Date: (o f 07 Tukwila Business License No.._ 0006136/3 �Crra' AKL ` I 1 L- 11 \Applications'.forms-Applications On Linc 2011 Applications\permit Application Revised - 8-9-11 docs Revised Auuust 2011 bh ARCHITECT OF RECORD Company Name: Fifth. 4. 1h77iU1J WORLD 4J117tr Architect Name:eA tS Sf4PiziV p Address: l i 1 .£t.")..%T City: coocido.JA'C ( State: C) Zip:z4s 2452 Phone: 5 3 24I. 3 0645 Fax: Email: ,15i e3tag, G (-,,,c...1„. CoM ENGINEER OF RECORD Company Name: Engineer Name: '1.01,6 1'ZOf31 SO ,3 Address: 1G4a 1 40Avt 14), Su1'C: 2402. City: oil 404,000b State: W A Zip: cc 60 If. Phone: 206 • 4. 3 3443 Fax: tiZS• 8 3s ► UO Ci$ Email: LENDER/BOND ISSUED (required for projects $5,000 or greater per/RCW 19.27.095) // D ^T Name: ft f p le— go q .{-a! .'.L y k r7 �/ AC Address: JQ ILi ct s>L /414;^ 54.�'+ r, `State: City: ziv( t v4 4 Zip: �32.19 Page 1 of 4 BUILDING PERMIT INFORMATIC 206-431-3670 Valuation of Project (contractor's bid price): $ ': $ q 6 •66' Existing Building Valuation: $ C7 e6,000 Describe the scope of work (please provide detailed information): 14t,f(Et. Lo(vY tS A 5Ad ti u' (bl% t i t, Foo k rM' (.verrovsm (3tA)& • 1,0644 17-6 J0VOrT'6. Is th.)(4.VS'v off- dt=FltE 2C.valrtcriJR14T+dw) Ati1? 1JeZJ FtN1544e-s +- EGtOke 41 • P ')O i'l I'kitni&k. ►24)Oo 1,,J G e-co-Y(44m 3vt0)1mt. 1 'Zc (. l e- a & AWA -C.. Std M• ANA) I (,vnl r, wrtn) ize-STAIJOAA•1 To 13‘ ACkecs1 g ur Will there be new rack storage? ❑ Yes X.. No If yes, a separate permit and plan submittal will be required. Provide All Building Areas in Square Footage Below PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Will there be a change in use? 0 Yes Compact: Handicap: No 1f "yes", explain: FIRE PROTECTION/HAZARDOUS MATERIALS: 01, Sprinklers ❑ Automatic Fire Alarm ❑ None ❑ Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? 0 Yes ❑ No If "yes', attach list of materials and storage locations on a separate 8-1/2" x 11" paper including quantities and Material Safety Data Sheets. SEPTIC SYSTEM ❑ On-site Septic System - For on-site septic system, provide 2 copies of a current septic design approved by King County Health Department. H:\Applications\Forms-Applications On Linc\2011 Applications\Permit Application Revised - 8-9-11 docx Revised. August 2011 bh Page 2 of 4 Existing Interior Remodel Addition to Existing Structure New Type of Construction per IBC Type of Occupancy per IBC 1St Floor 54:00 SC 6,44001(• MSc ryt€ 5 12-1 2" Floor 67SsP riot" 5 R- 1 OS -5i. 3rd Floor Floors thru Basement Accessory Structure* Attached Garage Detached Garage Attached Carport Detached Carport Covered Deck Uncovered Deck PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Will there be a change in use? 0 Yes Compact: Handicap: No 1f "yes", explain: FIRE PROTECTION/HAZARDOUS MATERIALS: 01, Sprinklers ❑ Automatic Fire Alarm ❑ None ❑ Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? 0 Yes ❑ No If "yes', attach list of materials and storage locations on a separate 8-1/2" x 11" paper including quantities and Material Safety Data Sheets. SEPTIC SYSTEM ❑ On-site Septic System - For on-site septic system, provide 2 copies of a current septic design approved by King County Health Department. H:\Applications\Forms-Applications On Linc\2011 Applications\Permit Application Revised - 8-9-11 docx Revised. August 2011 bh Page 2 of 4 PUBLIC WORKS PERMIT INFORMATION — 206-433-0179 Scope of Work (please provide detailed information): NV U.uP ' Call before you Dig: 811 Please refer to Public Works Bulletin #1 for fees and estimate sheet. Water District ❑ ...Tukwila ❑ ...Water District #125 ❑ ...Water Availability Provided Sewer District ❑ ...Tukwila 0 ...Sewer Use Certificate ❑ .. Highline ❑...Valley View 0 ..Renton ❑...Sewer Availability Provided ❑ .. Renton ❑ .. Seattle Septic System: 0 On-site Septic System — For on-site septic system, provide 2 copies of a current septic design approved by King County Health Department. Submitted with Application (mark boxes which apply): ❑ ...Civil Plans (Maximum Paper Size -22" x 34") 0 ...Technical Information Report (Storm Drainage) ❑ ...Bond 0 .. Insurance 0 .. Easement(s) Proposed Activities (mark boxes that apply): ❑ ...Right-of-way Use - Nonprofit for less than 72 hours ❑ ...Right-of-way Use - No Disturbance ❑ ...Construction/Excavation/Fill - Right-of-way 0 Non Right-of-way 0 ❑ ...Total Cut ❑ ...Total Fill cubic yards cubic yards ❑ ...Sanitary Side Sewer ❑ ...Cap or Remove Utilities 0 ...Frontage Improvements ❑ ...Traffic Control 0 ...Backflow Prevention - Fire Protection Irrigation Domestic Water ❑ .. Geotechnical Report 0 .. Maintenance Agreement(s) ❑ ...Traffic Impact Analysis ❑ ...Hold Harmless — (SAO) ❑ ...Hold Harmless — (ROW) ❑ .. Right-of-way Use - Profit for less than 72 hours ❑ .. Right-of-way Use — Potential Disturbance ❑ .. Work in Hood Zone ❑ .. Storm Drainage ❑ .. Abandon Septic Tank ❑ .. Curb Cut ❑ .. Pavement Cut ❑ .. Looped Fire Line ❑ ...Permanent Water Meter Size... ❑ ...Temporary Water Meter Size .. ❑ ...Water Only Meter Size ❑ ...Sewer Main Extension Public ❑ ...Water Main Extension Public If WO # WO# WO # Private 0 Private 0 0 .. Grease Interceptor ❑ .. Channelization 0 .. Trench Excavation ❑ .. Utility Undergrounding ❑...Deduct Water Meter Size FINANCE INFORMATION Fire Line Size at Property Line Number of Public Fire Hydrant(s) ❑ ...Water ❑ ...Sewer ❑ ...Sewage Treatment Monthly Service Billing to: Name: Day Telephone: Mailing Address: City State Zip Water Meter Refund/Billing: Name: Mailing Address: Day Telephone: City ( Stale Zip 11 \Applications\ Forms -Applications On Linet201 I A00 cationsd'ennit Application Revised - 8-9-11 docv Revised. Auwst 2011 Page 3 of 4 PERMIT APPLICATION NOTES — Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). I HEREBY CERTIFY THAT 1 HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR AUT+I Signature: IZE G NT: • Print Name: Mailing Address: 311 C.4..M. ST STC (p Qv H:\Applications\Forms-Applications On Line \20I 1 Applications\Permit Application Revised - 8-9-I I.docx Revised: August 2011 bh Day Telephone: G,Ju40 41 City Date: 0 Z- Ltk- Zv l 51). 31,2.1581 04 4S ZO 2, State Zip Page 4 of 4 Cash Register Receipt City of Tukwila DESCRIPTIONS 1 ACCOUNT I QUANTITY PermitTRAK I PAID $2,762.08 D16-0238 Address: 6955 FORT DENT WAY BLDG 4 Apn: 2954900460 $2,762.08 DEVELOPMENT $2,680.97 PERMIT FEE R000.322.100.00.00 0.00 $1,622.10 PLAN CHECK FEE R000.345.830.00.00 0.00 $1,054.37 WASHINGTON STATE SURCHARGE 8640.237.114 0.00 $4.50 TECHNOLOGY FEE $81.11 TECHNOLOGY FEE TOTAL FEES PAID BY RECEIPT: R9258 R000.322.900.04.00 0.00 $81.11 $2,762.08 Date Paid: Tuesday, August 23, 2016 Paid By: ZAI 2 Pay Method: CHECK 3007 Printed: Tuesday, August 23, 2016 2:40 PM 1 of 1 CRWSYSTEMS INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Prgject: j1�/ geab &iir Type of Inspection:, ck M-bil.dt- -lic,A-1- Address:Date rfe k7e L r Anil Called: Special Instructions: M/b6.- Zy Date Wanted: d /2/i 7 a.m. cp....r.,/i. Requester: Phone No: \IN Approved per applicable codes. LJ Corrections required prior to approval. COMMENTS: Ei7frci-L — inspector: Date: REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 bit -Q ? Pro� e_ct: � �'yL"i1 � � cpir6J^ Type of inspection: / 6r!/4- 2-/frf& r A/lddresss: ��,. ,,� WAY Date Called: Special Instructions: Date Wanted: a.m. Requester: Phone No: ,Zr- ”i- 242 Approved per applicable codes. I Corrections required prior to approval. COMMENTS: - z/A/G- Inspector: Date: REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit INSPE ON NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION (206) 431-3670 �►� - 6110 6300 Southcenter Blvd., #100, Tukwila. WA 98188 Permit inspection Request Line (206) 438-9350 Project: /�C40(54t.4% SJ /17 Type of Inspection: �1/1-141 1X(6 Address: c 4 S ger kzir lorN-1 Date Called: Special Instructions: at:us,.q Date Wante *i: Requeste : Phone No: ❑ Approved per applicable codes. COMMENTS: Corrections required prior to approval. mir6 Cfrifig vim& A-7— 4 ' REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION NO. INSPECTION RECORD Retain a copy with permit bit.- one PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project: 44/1747-4Z0 SUMS Type o J pection: kig474 ),J& Address: CG gri t1,AAi Date Called: Special Instructions: �l `j 7 Date Wanted: j / 2 /`�© l4t a.m. p.m. Requester: / Phone No: 90t1C44- -' Approved per applicable codes. t_J Corrections required prior to approval. COMMENTS: CAAJZOLLe6 - Ak27--- 12,61)bq 90t1C44- -' nv;cx.-r at% ea 1?f PL ( c� w )A� inspector: Date,Z i& REINSPECTION REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100: Call to schedule reinspection. VD INSPECTION_ Retain a copy permit ermit IN CTION NO. bids) SU? 9 PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project: Typ nspection: Address:( 4qs rfry/4 1 LNi% 1JAr ) Date Called: Special Instructions: Date Want d: j Request r: Phone No: Approved per applicable codes. Corrections required prior to approval. COMMENTS: Inspector: �/��'r `-�4 Date: l REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit INS ION NO Did 0238 PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 Permit Inspection Request line (206) 438-9350 (206) 431-3670 Pr��ect: /TiAY.° 50 S Typepection: -124M11J Address: 4qMr- r W4`/ Date Called: Special Instructions: ,3 1 1 q Date Want d: G '" a rr p.m. Requester Phone No: 'D 3 - X13 q - 3-i! 0 Approved per applicable codes. Corrections required prior to approval. COMMENTS: Wim-- reApti /we- OAJ Inspector: Dater z/6,// REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION NUMBER INSPECTION RECORD Retain a copy with permit PERMIT NUMBERS CITY OF TUKWILA FIRE DEPARTMENT 206-575-4407 Project: v6---5 Hrs.: ,.. Type of Inspection: f---74_ Address: ,. Suite #: SC.�_ t� �� - :Ji :' l Vivi Contact Person: !41 i I Special Instructions: Monitor: Phone No.: '`I Approved per applicable codes. Corrections required prior to approval. COMMENTS: v6---5 Hrs.: ,.. Sprinklers: ye' 5 Fire Alarm: t-' 5 ?ilk -1/ /V iM *,917:/4-°V&I) Hood & Duct: .V A----- �Monitor: Monitor: 1,-(4-70 G��✓ `'(2-- Pre -Fire: /V EFD5 vi09 Permits: 1y- Occupancy Type: Needs Shift Inspection: v6---5 Hrs.: ,.. Sprinklers: ye' 5 Fire Alarm: t-' 5 Hood & Duct: .V A----- �Monitor: Monitor: 1,-(4-70 G��✓ `'(2-- Pre -Fire: /V EFD5 vi09 Permits: 1y- Occupancy Type: Inspector: r -e2, 5-4. Date: irich Hrs.: ,.. $100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. Billing Address Attn: Company Name: Address: City: State: Zip: Word/Inspection Record Form.Doc 3/14/14 T.F.D. Form F.P. 113 INSPECTION NUMBER INSPECTION RECORD Retain a copy with permit PERMIT NUMBERS CITY OF TUKWILA FIRE DEPARTMENT 206-575-4407 Project: 0l 43?/ a Glob 5- %L SI Type of Inspe ion: ll Address: Suite#: R-, 55 �--- f -- O iJJ W4-, Contact Person: Special Instructions: 16/1 c 0/ - i.t16,- 7 t-e;NJ G t 0 . 12 t ;0 - t / u.- go - 7 i> ; t -4_, i five.) Phone No.: Approved per applicable codes. Corrections required prior to approval. COMMENTS: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: /1 /1f--` 16/1 c 0/ - i.t16,- 7 t-e;NJ G t 0 . 12 t ;0 - t / u.- go - 7 i> ; t -4_, i five.) /1 (Jt f'! (5Tr7 r iElirCC- v/!•j -')-j ►0 syf"L r,.//%( -.,___ -�- =.. / �(?� D? v 1 C- c `� pe: 3. ---/-b7 ! 't- r_ igrii I, ;14-.-- r1 -t c p, ,, e-- 6 ;viE t'-�j()1 `-1/' ''�-i- f'(C 9 s if itom0 N) 1 As 1) o - i Col �c.r c- 77 . Needs Shift Inspection: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: Inspector: FM S`; Date: ,7�,�%/1 ---LX___ Hrs.: $100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. Billing Address Attn: Company Name: Address: City: State: Zip: Word/Inspection Record Form.Doc 3/14/14 T.F.D. Form F.P. 113 i INSPECTION NUMBER INSPECTION RECORD Retain a copy with permit i[/( O -27-,-(f, PERMIT NUMBERS CITY OF TUKWILA FIRE DEPARTMENT 206-575-4407 Project: O �� 1Al t 9- t Type of Ins ,ection: le Ei, j7 L -(&72 Address: Suite #: Cc" --- v it -r- j -r t,JtA ,!a//v Contact Person: Special Instructions: / Phone No.: p` I Approved per applicable codes. Corrections required prior to approval. COMMENTS: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: CY : !/uk L e --?2- F!. 1/ C� r►/&" r 1 P-- it 6 e ALL— f-4-rEL 6-,1-1.- L2 0L4-7ce- 5 ,zn,(p 1-t 7— Needs Shift Inspection: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: Inspector: F-7,4 ,1 5 4— Date: i 117/1 Hrs.: $100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. Billing Address Attn: Company Name: Address: City: State: Zip: Word/Inspection Record Form.Doc 3/14/14 T.F.D. Form F.P. 113 6/5/2017 City of Tukwila Department of Community Development MIKE KEIFLING 311 ELM STREET, STE 600 CINCINNATI, OH 45202 RE: Permit No. D16-0238 HOMEWOOD SUITES TUKWILA 6955 FORT DENT WAY Dear Permit Holder: Allan Ekberg, Mayor Jack Pace, Director In reviewing our current records, the above noted permit has not received a final inspection by the City of Tukwila Building Division. Per the International Building Code, International Mechanical Code, Uniform Plumbing Code and/or the National Electric Code, every permit issued by the Building Division under the provisions of these codes shall expire by limitation and become null and void if the building or work authorized by such permit has not begun within 180 days from the issuance date of such permit, or if the building or work authorized by such permit is suspended or abandoned at any time after the work has begun for a period of 180 days. Your permit will expire on 7/5/2017. Based on the above, you are hereby advised to: 1) Call the City of Tukwila Inspection Request Line at 206-438-9350 to schedule for the next or final inspection. Each inspection creates a new 180 day period, provided the inspection shows progress. -or- 2) Submit a written request for permit extension to the Permit Center at least seven(7) days before it is due to expire. Address your extension request to the Building Official and state your reason(s) for the need to extend your permit. The Building Code does allow the Building Official to approve one extension of up to 180 days. If it is determined that your extension request is granted, you will be notified by mail. In the event you do not call for an inspection and/or receive an extension prior to 7/5/2017, your permit will become null and void and any further work on the project will require a new permit and associated fees. Thank you for your cooperation in this matter. Sincerely, � tttUUUUUUUUUUUU Rachelle Rip ey Permit Technician File No: D16-0238 Iii 6300 Southcenter Boulevard Suite #100 • Tukwila, Washington 98188 • Phone 206-431-3670 • Fax 206-431-3665 City of Tukwila Department of Community Development September 13, 2016 MIKE KEIFLING 311 ELM STREET, STE 600 CINCINNATI, OH 45202 RE: Correction Letter # 1 DEVELOPMENT Permit Application Number D16-0238 HOMEWOOD SUITES TUKWILA - 6955 FORT DENT WAY Dear MIKE KEIFLING, Allan Ekberg, Mayor Jack Pace, Director This letter is to inform you of corrections that must be addressed before your development permit can be approved. All correction requests from each department must be addressed at the same time and reflected on your drawings. I have enclosed comments from the following departments: BUILDING DEPARTMENT: Allen Johannessen at 206-433-7163 if you have questions regarding these comments. • (GENERAL NOTE) PLAN SUBMITTALS: (Min. size 11x17 to maximum size of 24x36; all sheets shall be the same size. New revised plan sheets shall be the same size sheets as those previously submitted.) (If applicable) "STAMP AND SIGNATURES" "Every page of a plan set must contain the seal/stamp, signature of the licensee(s) who prepared or who had direct supervision over the preparation of the work, and date of signature. Specifications that are prepared by or under the direct supervision of a licensee shall contain the seal/stamp, signature of the licensee and the date of signature. If the "specifications" prepared by a licensee are a portion of a bound specification document that contains specifications other than that of an engineering or land surveying nature, the licensee need only seal/stamp that portion or portions of the documents for which the licensee is responsible." It shall not be required to have each page of "specifications" (calculations) to be stamped and signed; Front page only will be sufficient. (WAC 196-23-010 & 196-23-020) (BUILDING REVIEW NOTES) 1. Plan code references throughout the plan set refer to past codes and accessible codes. As of July 1 2016 City of Tukwila adopted the 2015 International Building codes. Revise plan sheets, notes and related documents for compliance with the current 2015 International Building codes including 2015 UPC, 2015 WSEC, 2009 ANSI as well as all other relative 2015 codes and local Tukwila building codes. 2. The column on sheet id900 specifies 4000 pound concrete. Please clarify or specify the necessary special inspections. Also the plan detail doesn't specify the method of fasteners of the rafters to the wall ledger. Please specify. PW DEPARTMENT: Dave McPherson at 206-431-2448 if you have questions regarding these comments. • 1) Provide a completed Public Works permit fee estimate sheet for Public Works activities including domestic water backflow (RPPA w/HotBox), AMR upgrade to the existing irrigation deduct meters, Storz adapters installation, and backflow annual testing reports. (see PW Bulletin A2 enclosed) 2) In accordance with Washington State Department of Health guidelines for Group A Public Water Systems, Public Works has implemented a cross -connection control program to protect the public water system from contamination via cross -connection. The City has determined that the Homewood Suites Tukwila building has deficiencies on the domestic water backflow devices, fire prevention lines, and irrigation system; requiring the following upgrades. 6300 Southcenter Boulevard Suite #100 • Tukwila Washington 98188 • Phone 206-431-3670 • Fax 206-431-3665 a) Domestic Water A Reduced Pressure Principle Assembly (RPPA), previously called a Reduced Pressure Backflow Assembly (RPBA), shall be installed immediately downstream of each of the four existing permanent water meters. Installation at another location requires approval by the Director of Public Works. The RPPAs shall be installed in Hot Box/Rock or equal freeze protection enclosures anchored to a minimum 4" thick concrete pad. Public Works recommends, but does not require, a power supply for the freeze protection enclosure. On your site plan show the property lines, location of the domestic water meters and proposed RPPA locations. Please specify size/manufacturer/model number of the proposed RPPAs, and submit backflow cut sheets. NOTE: There are a total of five domestic water services and none have RPPA's installed for premise isolation. One of the domestic water services has a DCVA installed for premise isolation (believed to serve a laundry room) and it is overdue for testing. b) Fire Prevention The subject building has all necessary fire backflow preventers installed. However, there is an 8" fire line with a (DCDA) and a 4" fire line with a (DCVA) that are both overdue for mandatory annual testing. Please have both backflows tested by a certified tester ASAP and submit passing test reports to the City. The two existing fire department connections on the fire lines need to have Storz adapters installed. Please note that plans for the fire protection backflow retrofit design must be stamped, signed and dated by a Level III certificate of competency holder or by a professional engineer. c) Landscape Irrigation The annual test required by the Washington State Department of Health for the existing 1" irrigation backflow device (DCVAs) are overdue for testing. Please have the backflow devices tested by a certified tester and submit passing test reports to Public Works. An AMR upgrade to the existing irrigation deduct meters are required. The two existing sewer deduct meters on the irrigation system are not compatible with our AMR meter reading system. The existing irrigation exempt water meters shall be upgraded with AMRs (compatible with SENSUS). In order to connect the deduct meters to the permanent meter reading system, connect the two boxes using PVC conduit. If you need assistance in locating any of these backflows in the field, please contact Mr. Todd Reedy, Tukwila Water Department, directly at (206) 571-6309. Additional contact is Mike Cusick, P.E., Public Works Senior Water and Sewer Engineer at (206) 431-2441 The Public Works Director will withhold issuance of the Homewood Suites Tenant Improvement permit D16-0238 until the Permit Center receives a revision to this TI permit application or a separate Public Works Type C Construction permit that includes plans for domestic water backflow (RPPA w/HotBox), AMR upgrade to the existing irrigation deduct meters, and Storz adapters installation; together with a construction cost estimate for items a) and b) above. When submitting for a Type C permit, Public Works collects a base application fee and plan review and ($250.00 plus 2.5% of construction cost for RPPAs and backflow testing). An additional 2.5% of subject construction cost will be paid at the time of permit issuance. Applicant also has an option to post a bond for these backflow installations in the amount equal to 150% of the design, installation and testing cost of the subject backflows, together with a letter confirming the installation within no more than 90 days. I have enclosed Public Works Bulletin C5 (design and installation requirements for cross connection control), which describes design and installation requirements for cross connection control. Please address the comments above in an itemized format with applicable revised plans, specifications, and/or other documentation. The City requires that two (2) sets of revised plan pages, specifications and/or other documentation be resubmitted with the appropriate revision block. In order to better expedite your resubmittal, a 'Revision Submittal Sheet' must accompany every resubmittal. I have enclosed one for your convenience. Corrections/revisions must be made in person and will not be accepted through the mail or by a messenger service. 6300 Southcenter Boulevard Suite #100 • Tukwila Washington 98188 • Phone 206-431-3670 • Fax 206-431-3665 If you have any questions, I can be 1.,..,;hed at 206-431-3655. Sincerely, 1)12E? Bill Rambo Permit Technician File No. D16-0238 6300 Southcenter Boulevard Suite #100 • Tukwila Washington 98188 • Phone 206-431-3670 • Fax 206-431-3665 City of Tukwila Allan Ekberg, Mayor Public Works Department - Bob Giberson, Director September 8, 2016 Homewood Suites Tukwila 6955 Fort Dent Way Tukwila, WA 98168 RE: Homewood Suites Tukwila Tenant Improvement 6955 Fort Dent Way, Tukwila, WA Permit Number: D16-0238 To Whom It May Concern: 1) In accordance with Washington State Department of Health guidelines for Group A Public Water Systems, Public Works has implemented a cross -connection control program to protect the public water system from contamination via cross -connection. Since the project included alterations to the existing plumbing system, the entire plumbing system must be brought up to the current standards as set forth in the Uniform Plumbing Code including installation of approved backflow prevention on the domestic, fire prevention and irrigation water supply lines to the building. The program requires elimination or control of any cross -connection between the distribution system and a consumer's water system by the installation of approved backflow devices. The City has determined that the building at the above address has deficiencies on the domestic water, fire prevention lines, and irrigation system requiring the following upgrades. a) Domestic Water A Reduced Pressure Principle Assembly (RPPA), previously called a Reduced Pressure Backflow Assembly (RPBA), shall be installed immediately downstream of each of the four existing permanent water meters. Installation at another location requires approval by the Director of Public Works. The RPPAs shall be installed in Hot Box/Rock or equal freeze protection enclosures anchored to a minimum 4" thick concrete pad. Public Works recommends, but does not require, a power supply for the freeze protection enclosure. On your site plan show the property lines, location of the domestic water meters and proposed RPPA locations. Please specify size/manufacturer/model number of the proposed RPPAs, and submit backflow cut sheets. NOTE: There are a total of five domestic water services and none have RPPA's installed for premise isolation. One of the domestic water services has a DCVA installed for premise isolation (believed to serve a laundry room) and it is overdue for testing. b) Fire Prevention The subject building has all necessary fire backflow preventers installed. However, there is an 8" fire line with a (DCDA) and a 4" fire line with a (DCVA) that are both overdue for mandatory annual testing. Please have both backflows tested by a certified tester ASAP and submit passing test reports to the City. The two existing fire department connections on the fire lines need to have Storz adapters installed. Please note that plans for the fire protection backflow retrofit design must be stamped, signed and dated by a Level III certificate of competency holder or by a professional engineer. 6300 Building • 6300 Southcenter Boulevard Suite 100 • Tukwila, WA 98188 • 206-433-0179 Tukwila City Hall • 6200 Southcenter Boulevard • Tukwila, WA 98188 • 206-433-1800 • Website: TukwilaWA.gov Homewood Suites Tukwila September 2, 2016 Page 2 c) Landscape Irrigation The annual test required by the Washington State Department of Health for the existing 1" irrigation backflow devices (DCVAs) are overdue for testing. Please have the backflow devices tested by a certified tester and submit passing test reports to Public Works. An AMR upgrade to the existing irrigation deduct meters are required. The two existing sewer deduct meters on the irrigation system are not compatible with our AMR meter reading system. The existing irrigation exempt water meters shall be upgraded with AMRs (compatible with SENSUS). In order to connect the deduct meters to the permanent meter reading system, connect the two boxes using PVC conduit. If you need assistance in locating any of these backflows in the field, please contact Mr. Todd Reedy, Tukwila Water Department, directly at (206) 571-6309. Additional contact is Mike Cusick, P.E., Public Works Senior Water and Sewer Engineer at (206) 431-2441 The Public Works Director will withhold issuance of the Homewood Suites Tenant Improvement permit D16- 0238 until the Permit Center receives a revision to this TI permit application or a separate Public Works Type C Construction permit that includes plans for RPPA installations, together with a construction cost estimate for items a) and b) above. When submitting for a Type C permit, Public Works collects a base application fee and plan review and ($250.00 plus 2.5% of construction cost for RPPAs and backflow testing). An additional 2.5% of subject construction cost will be paid at the time of permit issuance. Applicant also has an option to post a bond for these backflow installations in the amount equal to 150% of the design, installation and testing cost of the subject backflows, together with a letter confirming the installation within no more than 90 days. I have enclosed Public Works Bulletin C5 (design and installation requirements for cross connection control), which describes design and installation requirements for cross connection control. Sincerely, David H. McPherson Development Engineer Public Works Department City of Tukwila David.mcpherson @tukwilawa.gov 206-431-2448 DHM:lw enclosures: Public Works Bulletin C5 Public Works Permit Application cc: D16-0238 File Mike Cusick, Senior Water and Sewer Engineer Todd Reedy, Water Department (W:PW Eng/Other/Dave McPherson/Letter Homewood Suites Tukwila 090816) PERMIT COORD COPY PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: D16-0238 DATE: 09/20/16 PROJECT NAME: HOMEWOOD SUITES TUKWILA SITE ADDRESS: 6955 FORT DENT WAY Original Plan Submittal X Response to Correction Letter # 1 Revision # Revision # before Permit Issued after Permit Issued DEPARTMENTS: PO MO ar Building Division; Public Works itt Fire Prevention Structural Planning Division ❑ Permit Coordinator PRELIMINARY REVIEW: Not Applicable — (no approval/review required) REVIIEWER'S INITIALS: DATE: 09/22/16 Structural Review Required DATE: APPROVALS OR CORRECTIONS: Approved Corrections Required n (corrections entered in Reviews) Notation: r Une61 Approved with Conditions Denied (ie: Zoning Issues) DUE DATE: 10/20/16 n REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg 0 Fire ❑ Ping 0 PW 0 Staff Initials: 12/18/2013 PERMIT COORD COPY PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: D16-0238 DATE: 08/26/16 PROJECT NAME: HOMEWOOD SUITES TUKWILA SITE ADDRESS: 6955 FORT DENT WAY X Original Plan Submittal Response to Correction Letter # Revision # Revision # before Permit Issued after Permit Issued DEPARTMENTS: Binding Division `COY( mimic Works Pil'lil • x,119 Fire Prevention Structural Planning A %1' Division. �Y ❑ Permit Coordinator PRELIMINARY REVIEW: Not Applicable ❑ (no approval/review required) REVIEWER'S INITIALS: DATE: 08/30/16 Structural Review Required DATE: APPROVALS OR CORRECTIONS: Approved Corrections Required (corrections entered in Reviews) Notation: DUE DATE: 09/27/16 Approved with Conditions ❑ Denied (ie: Zoning Issues) REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: �y o Departments issued corrections: Bldg k /Fire ❑ Ping ❑ PW ]. Staff Initials: 12/18/2013 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206-431-3665 Web site: http://www.ci.tuhwila.wa.us REVISION SUBMITTAL Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the wail, fax, etc. Date: 05' Ig • 20%y Plan Check/Permit Number: D16-0238 ❑ Response to Incomplete Letter # ® Response to Correction Letter # 1 ❑ Revision # after Permit is Issued ❑ Revision requested by a City Building Inspector or Plans Examiner Project Name: Homewood Suites Tukwila Project Address: 6955 Fort Dent Way Contact Person: Nice- 111Fk.ip l(1 Phone Number: 553 ,2• IS8 Summary of Revision: _T ??ZviSitti S t SPnn1Sr, Tb TH€ Lct&tec (,E -1T1 . • )4cu4mat); IzEFeltegcx M bluttuvr t&&W%Li! erlDirS RCxrn1. co...) LQ 41( iter kolitexke.st 5 f , Nsb iZAQ riL TTA Ofu t zt NAT -MOS, Au_ C> *' t fi, Atte'c'-'Ut7E qa tAtit I.Er) wk -t4 i- A RECEIVED CITY OF TUKWILA. SEP 202016 PERMIT CENTER Sheet Number(s): Cot SR Stiger , 2,6.00k O.00 iN1 1 Z 0.O1 tRttE'6Stg.ury, IC( .00 svTalL � 7A`S "Cloud" or highlight all areas of revision including date of revision � Received at the City of Tukwila Permit Center by: [✓ Entered in TRAKiT on 'P'1(1) \applications\forms-applications on line\revision submittal Created: 8-13-2004 Revised: ZERR & ASSOCIATES INC Page 1 of 2 Home E.spauol Contact Search L&I A-7, Index help ,MvL£�I Safety & Health Claims & Insurance Workplace Rights Trades & Licensing 0 Washington State Department of Labor & Industries ZERR & ASSOCIATES INC Owner or tradesperson Principals ZERR, MICHAEL ANTON, PRESIDENT ZERR, ELDON ANTHONY, SECRETARY ZERR, ELDON ANTHONY, TREASURER Doing business as ZERR & ASSOCIATES INC WA UBI No. 602 928 251 5650 E EVANS AVE SUITE 110 DENVER, CO 80222 303-758-7776 Business type Corporation License Verify the contractor's active registration / license / certification (depending on trade) and any past violations. Construction Contractor Active. Meets current requirements. License specialties GENERAL License no. ZERRAAI914LK Effective — expiration 06/12/2009— 06/20/2017 Bond American Contractors Indem CO Bond account no. 1000789805 $12,000.00 Received by L&I Effective date 06/12/2009 06/08/2009 Expiration date Until Canceled Insurance Kinsale Insurance Company $1,000,000.00 Policy no. 01000291111 Received by L&I Effective date 05/20/2016 05/15/2016 Expiration date 05/15/2017 Insurance history Savings ............... No savings accounts during the previous 6 year period. Lawsuits against the bond or savings No lawsuits against the bond or savings accounts during the previous 6 year period. L&I Tax debts Help us improve https://secure.lni.wa.gov/verify/Detail.aspx?UBI=602928251 &LIC=ZERRAAI914LK&SAW= 10/27/2016 Apple Hospitality REIT, Inc. FRCH DESIGN WORLDWIDE BY HHLTONTM "TAKE FLIGHT" INTERIOR RENOVATION TUKWILA, WA inn code: SEATK REVISIONS No changes ;hail be made to the scope of work without prior approval of Tukwila Building Division NOTE: Reviulons will roquiro a n^w p'an submittal and may in,-.:`udo add tional plan reviaw fees. SEE V:I E F'E;"';ilT REQUiP"j FOR: ❑ Mccbanical ❑ Electrical ❑ Plumbing ❑ Cas Piping Cil; of Tukwila ButL17fl VI 'ICN FILE COPY Permit ©. Plan review approval is subject to errors and omissions. Approval of construction documents does not authorize the violation of any adopted code or ordinance. I:1=1;A of approved Field Copy and conditions is acknowledged: By: AN N A p & Date: f City of Tukwila BUILDING DIVISION REVfE WED FOR 1 CODE COMP%LANCE APPROVED OCT 2 5 2016 City of Tukwila BUILDING DIVISION RECEIVED CITY QF TUKWILA SEP 202016 PERMIT CENTER FRCH Project No: 032609.000 REVISION [1] -BUILDING DEPT. COMMENTS PERMIT, CONSTRUCTION, AND BID SET BRAND REVIEW SET 09.19.2016 08.19.2016 04.28.2016 P CORRECTION T # LAYOUT: id0.00 urr cri 0 CO0 N PLOTTED: 9/19/2016 - 2:22 PM FI G D C A 7 8 10 11 12 13 14 Index to, Drawing Symbols ID. 6 SHEETLOCARON illibillh_afer to xxx ID. NUMBER ELEVATION REFERENCE KEY NOTE Illir Referto xxx MATCH LINE ALIGNMENT SIDE 410 REFER TosHEEr (INTERIOR and\or EXTERIOR) WORK ID.NUMOER REFERENCETAG �REEERr"sHEEr GENERAL\TYPICAL USE)(INTERIOR ( mT\ REFER To SHEET ELEVATION REFERENCE ONLY) T\WAWALL ELEVATION, POINT, DATUM CODE, PROVIDE: RESPONSIBLE �� ELEVATION ID. PREPARATION, FURNISH: RESPONSIBLE 728.9896' SPOT ELEVATION & or & L or L @ SF or S.F. or' # +/- or ± A.B. A/C ACOUST. ADJ. AFF or A.F.F. AFG orA.F.G ALUMN. or ALUM. ANGL. APPROX. ARCH. ASPH. ATTN. or ATTEN. BVooe< BD. BIT. BLDG. BLK. BLKG. BM. BOT. BRG. BRK. BRKMTL. B.U.R. C or CH. CAB. CB or C.B. C\C or C.0 CCTV or C.C.T.V. Cer. CL or C.L. or . Cor CLNG CMMUU or C.M.U. C.O. COL. COMB. COMP. or COMPT: CONC. CONST. CONT. CORR. C.W. CJ or C.J. CLR. D, DN. DWN. DBL. DEPT. DETL. or DTL, DIA. or 0 D.F. DIV. DR. or DRN. DS. or D.S. DWG(S). E or E. EA. EJ or EJ. or E.J. EL. or ELE. ELEC. or ELECT. ELEV. EMER. or EMERG. ENCL. ENG. EP or E.P. EQ. EQUIP. EWC or E.W.0 E.W. EXIST. EXP. EXT. F.A. F.B. .B or F.D. FD.FD F.E. F.E.C. xx e ROOM NAME '4016------1SECTION REFERENCE REVISION CLOUD &DELTAIlle, ROOM ID. No. ROOM IDENTIFICATION Board Bituminous Building Block Blocking Beam Bottom Bearing Brick Break Metal Built Up Roofing Channel Cabinet Cement Board Center to Center Closed Circuit Television Ceramic Centerline Ceiling Concrete Masonry Unit Cased Opening Column Combination or Combine Compact(ed) Concrete Construction Continuous Corridor Cold Water Control Joint Clear Down Double Department Detail Diameter Drinking Fountain Division Drain Downspout Drawing(s). East Each Expansion Joint Elevation Electrical Elevator Emergency Enclosure Engineer Electrical Panel Equal Equipment Electrical Water Cooler Each Way Existing Expansion Exterior Fire Face AlarmBrick Floor orcin Foundationu nguisher Fire Extinguisher Cabinet Finish dr& DOOR N ND. ACCESSIBILITY NOTES: PUBLIC SPACES 2 KHWN 1 DOOR IDENTIFICATION - SECTION STRUCTURAL GRID SITE PLAN, EGRESS PLAN )REFERENCE O._0 - TOWER'PLACE HOLDER" MATES FINISH IDENTIFICATION COLOR 1BKEAB-B TO LOCATE C.L BETWEEN GUESTROOMS id1.01 & ,.....^ J •ENLARGED ZZ H 5 F•5 O #' - #' FINISHED CEILING HEIGHT AFF REFERENCE •a•••* . y Q- WALL PARTITION TYPE STANDARD GARAGE NO COL COLS. ONLY AT COLUMN COLUMN EXISTS MAIN�LOWER LEVEL SIS GAUGE C ACCESSORY/FURNITURE, OR, MILLWORK REFERENCE. REFERENCE 1 STUD IDENTIFICATION WALLTYPEO (MORE ON WALL TYPE OR SHEETS WHERE USED) . WALL PARTITION TYPE SPA ING REMf , SEALANT JOINT REFERENCE W/ MODIFIER \ 0 4 ALIGN CONSTRUCTION HOLD CLOUD t GRAIN WOOD GRAIN DIRECTION F 6 6 id4.11 Abbreviations & Definitions EXISTING GUESTROOM COUNT Drawing No. Where additional abbreviations, or word definitions, are defined occurs, their definition shall take precedence over the flowing abbreviation is undefined - CALL the Architect, do not assume. by another discipline and a conflict on their sheets only. Where an NECESSARY: WORK NEEDED To COMPLETE THE WORK. To: "MAKE IT OPERATIONAL". NEEDED To BE IN COMPLIANCE WITH BUILDING CODE, GOVERNING OR JURISDICTION HAVING AUTHORITY. FOR PURCHASE, DELIVERY, RECEIVING, INSPECTION, STORAGE, AND INSTALLATION OF ITEM(S). FOR PUCHASE AND DELIVERY OF ITEM(S) FOR RECEIVING, INSPECTION, STORAGE, PREPARATION AND OF ITEM(S). REQUIRED: WORK Issue Date For CODE, PROVIDE: RESPONSIBLE Abbreviations definitions within 0 are content specific, or optional, depending on the note. example: Content: Refer to Arch. would be read: "Refer to Architectural" Contact Arch. would be read: "Contact Architect" Optional: Dwg.=Drawing and Dwgs.=Drawings PREPARATION, FURNISH: RESPONSIBLE INSTALL: RESPONSIBLE INSTALLATION & or & L or L @ SF or S.F. or' # +/- or ± A.B. A/C ACOUST. ADJ. AFF or A.F.F. AFG orA.F.G ALUMN. or ALUM. ANGL. APPROX. ARCH. ASPH. ATTN. or ATTEN. BVooe< BD. BIT. BLDG. BLK. BLKG. BM. BOT. BRG. BRK. BRKMTL. B.U.R. C or CH. CAB. CB or C.B. C\C or C.0 CCTV or C.C.T.V. Cer. CL or C.L. or . Cor CLNG CMMUU or C.M.U. C.O. COL. COMB. COMP. or COMPT: CONC. CONST. CONT. CORR. C.W. CJ or C.J. CLR. D, DN. DWN. DBL. DEPT. DETL. or DTL, DIA. or 0 D.F. DIV. DR. or DRN. DS. or D.S. DWG(S). E or E. EA. EJ or EJ. or E.J. EL. or ELE. ELEC. or ELECT. ELEV. EMER. or EMERG. ENCL. ENG. EP or E.P. EQ. EQUIP. EWC or E.W.0 E.W. EXIST. EXP. EXT. F.A. F.B. .B or F.D. FD.FD F.E. F.E.C. And Angle At Square Foot(age) Pound(s) or Number Plus Minus Anchor Bolt Air Conditioning Acoustical Adjacent Above Finish Floor Above Finish Grade Aluminum Angle Approximate Archltect(ural) Asphalt Attention Bottom of FL. or FLR. FLUOR. FRM. F.R. F.R.C. F.R.T. F.R.P. FT. FTG. FUT. or FUTR. FV. or F.V. Ga. GALV. G.B. GEN. GFRC GFRG GL. or GLAZ. GRAN. G.S.M. G.V. GYP. GYP. BD. H HC. or H.C. H.B. HDWD. HDWR. HGT. or HT. HM. H.M. or H.M.F. HORIZ. H.P. HTG. HR. or Hr. HVAC or H.V.A.C. H.W. I.D. IN INCL. INFO. INSUL. INT. INV. JC or J.C. JAN. JT. orJNT. KIT. K.O. LAB. LAM. LAV. LB. or LBS. LGMF L.P. LT. LT. WT. L.L.H. or LLH L.L.V. or LLV MAS. MAX. MED. MDO or M.D.O. MECH. MFR. or MANUF. M.H. MIN. MISC. M.O. MR. or M.R. MTD. MTG. MTL. MULL. N or N. NA. or N.A. NEC"( N.I.C. No. NOM. NON COMB. N.T.S. Floor Fluorescent Frame Fire Resistant Fiber Reinforced Concrete Fire Retardant Treated Fiber Reinforced Plastic Foot(Feet) Footing Future Field Verify Gauge Galvanized Gypsum Board General Glass Fiber Reinforced Concrete Glass Fiber Reinforced Gysum Glass/Glazing Granular Galvanized Sheet Metal Gas Valve Gypsum Gypsum Board High Handicapped Hose Bib Hardwood Hardware Height Hollow Metal Horizontal High Point Heating Hour Heating, Ventilation, & A\C Hot Water Inside Diameter Inch(es) Include Information Insulation Interior Invert Janitor's Closet Janitorial) Joint Kitchen Knockout Laboratory Laminate Lavatory Pound(s) Light Gauge Metal Framing Low Point Light Light Weight Long Leg Horizontal Long Leg Vertical Masonry Maximum Medium Medium Density Overlay Mechanical Manufacture Man Hole Minimum Miscellaneous Masonry Opening Moisture Resistant Mounted Mounting Metal Mullion North Not Applicable Necessary Not in Contract Number Nominal Non Combustible Not To Scale O.A. O.C. 0.11 OFF. O.H. OPNG. OPP. O.T.O. PART. PL P. LAM. or P.L. PLAS. PLBG. PLWD. PLYWD. PNL. PORC. PR. P.S.F. P.T. POST TEN. PTN. or PARTN. R R.A. RAD. RD. or R.D. REC. RECV or RECVD REF. or RE: REFR. REG. REINF. REQ'D. RES. RM. R.O. S or S. SB SCHED. or SCHEDL. SECT. SHT. SIM. SM.PE or S.M. SPEC. SQ. ST or S.S. ST. STD. ST STO STRUCT. SUSP. SYM. TVOOO( T or T. TEL. TEMP. T&B T&G THRU TS or T.S. TV or T.V. TYP. U.N.O. UR. or URNL. VAR. VCT or V.C.T. VB or VB. or V.B. VERT. VIF. V.I.F. W or W. W/ W/0 W.C. WC WD. W.F. WIN. W.P. W.M. WWF or W.W.F. WWM or W.W.M. . WSCT. wr• W.V. Overall On Center Overflow Drain or Outside Dia. Office Overhead or Opposite Hand Opening Opposite Out to Out Particle, Partial or Partition Plate Plastic Laminate Plaster Plumbing Plywood Panel Porcelain Pair Pounds per Square Foot Pressure Treated Post Tensioned Partition Riser Retum Air Radius Roof Drain Recessed Receive or Received Refer or Referenced Refrigerator Regular or Register Reinforce(d) Required Resilient Room Rough Opening South Stone Base Schedule Section Sheet Similar Surface Mounted Specification Square StainlessSteel Streett Standard Steel St ge Structural Suspended Symmetrical Top of Board Bituminous Building Block Blocking Beam Bottom Bearing Brick Break Metal Built Up Roofing Channel Cabinet Cement Board Center to Center Closed Circuit Television Ceramic Centerline Ceiling Concrete Masonry Unit Cased Opening Column Combination or Combine Compact(ed) Concrete Construction Continuous Corridor Cold Water Control Joint Clear Down Double Department Detail Diameter Drinking Fountain Division Drain Downspout Drawing(s). East Each Expansion Joint Elevation Electrical Elevator Emergency Enclosure Engineer Electrical Panel Equal Equipment Electrical Water Cooler Each Way Existing Expansion Exterior Fire Face AlarmBrick Floor orcin Foundationu nguisher Fire Extinguisher Cabinet Finish Tread Telephone Temprary or Tempered Top and Bottom Tongue and Groove Through Tube Steel Television Typical Unless Noted Otherwise Urinal Varies \Variable Vinyl Composition Tile Vinyl Base Vertical Verify in Field West With Without Water Closet Wall Covering Wood Wide Flange Window Waterproof Wire Mesh Welded Wire Fabric Welded Wire Mesh Wainscot WeightFIN. Water Valve id0.01 ACCESSIBILITY NOTES: PUBLIC SPACES 2 KHWN A. AL Interior General Project Notes: 1. ALL WORK AND FINAL FINISHED PRODUCTS SHALL BE COMPLETE IN EVERY RESPECT TO THE SATISFACTION OF THE OWNER. 2. EACH CONTRACTOR SHALL BE RESPONSIBLE FOR VERIFYING ALL DIMENSIONS, CONDITIONS, CONSTRUCTION, MATERIALS, AND DETAILS IN THE FIELD PRIOR T0: PREPARATION OF SHOP DRAWINGS, PRE -FABRICATION OR ORDERING OF MATERIAL, AND ACTUAL CONSTRUCTION. THE OWNER'S PROJECT MANAGER, AND THE ARCHITECT SHALL BE NOTIFIED IMMEDIATELY WHEN DISCREPANCIES ARE DISCOVERED. THE CONTRACTOR SHALL ASSUME MODIFICATIONS TO DETAILS AFFECTED BY EXISTING CONDITIONS ARE SUBJECT TO REVIEW BY THE ARCHITECT. 3. DO NOT SCALE DRAWINGS. WRITTEN DIMENSIONS ARE THE ONLY ACCEPTABLE MEANS OF LOCATION. 4. ALL DIMENSIONS ARE TO FINISH FACE OF GYPSUM BOARD AND/OR INDICATED MATERIAL U.N.O. 5. THE CONTRACTOR SHALL REMEDY WITHOUT COST TO THE OWNER, ANY DEFECTS DUE TO THEIR FAULTY WORKMANSHIP OR INSTALLATION OVER IMPROPER SUBSTRATE WITHOUT PRIOR CORRECTION. 6. ALL WORK SHALL BE DONE TO MEET OR EXCEED THE STANDARDS OF THE CONSTRUCTION PRACTICES OF EACH TRADE. 7. CONTRACTORS ARE RESPONSIBLE FOR ALL WORK INDICATED, OR INFERRED, WITHIN THESE CONSTRUCTION DOCUMENTS UNLESS SPECIFICALLY NOTED "BY OTHERS" AND/OR "N.I.C." IN ADDITION, EACH CONTRACTOR SHALL BE RESPONSIBLE FOR COORDINATING, AND SCHEDULING THEIR WORK WITH THE WORK OF THE OTHER TRADES, IDENTIFIED OR OTHERWISE, WITHIN THESE DOCUMENTS. COORDINATION SHALL INCLUDE WORK SPECIFICALLY IDENTIFIED AS: "BY OTHERS" AND/OR "N.I.0". 8 CONTRACTORS SHALL IMMEDIATELY NOTIFY THE ARCHITECT, AND OWNER, OF ANY DISCREPANCIES IN THE CONSTRUCTION DOCUMENTS: CONTRACTORS SHALL NOT PROCEED, OR ALLOW THEIR SUB -CONTRACTORS TO PROCEED, WITH WORK IN THOSE AREAS UNTIL SAID DISCREPANCIES ARE RESOLVED. 9. CONTRACTORS SHALL ADHERE TO ALL DESIGN CRITERIA INCLUDED WITHIN THE CONSTRUCTION DOCUMENTS UNLESS SPECIFICALLY MODIFIED BY AN ADDENDUM, BULLETIN, OR FIELD SKETCH AS ISSUED BY THE ARCHITECT OR ENGINEER(S). 10.CONSTRUCTION ELEMENTS BE INSTALLED PER THE MFR'S. SPECIFICATIONS AND INSTALLATION INSTRUCTIONS, WHERE ADDITIONAL ASTM,TRADE GUILD,AND OR ALL CONSTRU 10SHALL/ TRADE ASSOCIATION INFORMATION IS REFERENCED, THOSE REQUIREMENTS SHALL ALSO BE FOLLOWED. THE CONTRACTOR INSTALLING SAID ELEMENTS, SHALL ENSURE THE SUBSTRATE BEING INSTALLED OVER, COMPLIES WITH THE ABOVE REFERENCED REQUIREMENTS. WHERE THE SUBSTRATE IS NEW CONSTRUCTION PREVIOUSLY INSTALLED BY ANOTHER TRADE, THAT TRADE (CONTRACTOR) SHALL BE RESPONSIBLE FOR REMEDIATION OF THEIR WORK PRIOR TO PROCEEDING. FOR ( IF -#) ITEMS REFER TO THE FF&E SPECIFICATION BOOK. ITEMS REFER TO THE MATERIAL REFERENCE BOOK. FINISH SAMPLES, HARDWARE CUT SHEETS AND MILLWORK SHOP DRAWINGS ARE TO BE PROVIDED TO THE DESIGNER FOR REVIEW AND APPROVAL PRIOR TO ITEM FABRICATION AND/OR INSTALLATION. 14. ALL MILLWORK CABINETRY LOCKING DEVICES ARE TO BE FURNISHED AND INSTALLED BY THE GENERAL CONTRACTOR. ALL CABINETRY LOCKING DEVICES ARE TO BE PROVIDED WITH INTERCHANGEABLE CORES. CONTRACTOR IS TO COORDINATE WITH PROPERTY LOCKSMITHS FOR PREFERRED DEVICE MANUFACTURER AND INSTALLATION LOCATIONS. CONTRACTOR IS TO TURN OVER ALL EXISTING KEYS TO PROPERTY LOCKSMITHS AT PROJECT COMPLETION. 15. ALL PAINTED MOLDINGS ARE TO BE FABRICATED FROM MEDIUM DENSITY FIBERBOARD (MDF) WITH PRIMED FINISH. ALL SEAMS TO BE FILLED FOR SMOOTH SEAMLESS FINISH UNLESS NOTED OTHERWISE. ANY SUBSTITUTION OF MATERIALS MUST RECEIVE APPROVAL PRIOR TO FABRICATION. 16. ALL STAINED WOOD AND WOOD RECEIVING A SPECIAL FINISH SHALL BE FABRICATED FROM A STAIN GRADE WOOD AS SPECIFIED BY DESIGNER. ANY SUBSTITUTION OF MATERIALS OR SPECIES MUST RECEIVE DESIGNER APPROVAL PRIOR TO FABRICATION. 17. SUBMITTAL OF ALL MILLWORK SAMPLES SHALL HAVE THEIR FINISH APPLIED TO ACTUAL PRODUCTION MATERIAL. 18. MARINE GRADE PLYWOOD SHALL BE USED AT ALL WET LOCATIONS INCLUDING SUBSTRATES FOR STONE AND TILE FINISHES. UNLESS NOTED OTHERWISE. 19. INSTALL ALL ITEMS RIGID AND SECURE, PLUMB AND LEVEL. IN ALL INSTANCES WHERE MILLWORK OR CASEWORK ADJOINS OTHER WORK, THE MILLWORK OR CASEWORK SHALL BE SCRIBE CUT TO MAKE A NEAT AND PRESENTABLE JOINT. 20. THE GENERAL CONTRACTOR IS TO ALIGN AND FLOAT ALL FLOOR FINISH MATERIALS WITH ADJACENT MATERIALS UNLESS NOTED OTHERWISE ON THE FLOOR FINISH PLANS. 21. THE CARPET INSTALLER MUST PROVIDE A CARPET SEAM LOCATION PLAN TO OWNER FOR APPROVAL PRIOR TO INSTALLATION OF CARPET. 22. ALL EXISTING FIRE SPRINKLER HEADS, HVAC DIFFUSERS, RETURN AIR GRILLES, LIGHT FIXTURES, SPEAKERS, CAMERAS, EXIT SIGNS, ETC. ARE TO REMAIN UNLESS NOTED OTHERWISE ON THE ARCHITECTURAL AND/OR CONSULTANT DRAWINGS TO BE REMOVED OR RELOCATED. 23. ALL EXISTING & NEW CEILING HVAC GRILLES, LIGHT FIXTURE TRIMS, SPEAKER TRIMS, DOME CAMERA MOUNTING PLATES AND OTHER PAINTABLE ELEMENTS SHALL BE FINISHED TO MATCH THE ADJACENT NEW CEILING FINISH IN SATIN ENAMEL UNLESS NOTED OTHERWISE. General Demolitions Notes: DEMOLITION SHALL NOT BE LIMITED SOLELY TO THOSE ITEMS SHOWN WITHIN THE DEMOLITION DRAWING(S). 2. THE FULL SCOPE OF DEMOLITION REQUIRES A REVIEW OF THE ENTIRE DOCUMENT DRAWING SET, AS WELL AS A SITE VISIT TO REVIEW THE PROJECT SITE. CONTRACTOR SHALL REVIEW ANY EXISTING DOCUMENTATION OF THE PROJECT SPACE TO BETTER UNDERSTAND THE EXISTING CONDITIONS. OMISSIONS WHICH OCCUR DUE TO INCOMPLETE REVIEW WILL NOT BE ENTERTAINED. 3. REMOVE FROM THE SITE AND LEGALLY DISPOSE OF ALL REFUSE, DEBRIS, RUBBISH AND OTHER MATERIALS RESULTING FROM DEMOLITION OPERATIONS. DEBRIS SHALL BE REMOVED ON A REGULAR BASIS SO IT DOES NOT INTERFERE WITH THE DEMOLITION/CONSTRUCTION WORK OR THE NORM4L OPERATIONS OF THE FACILITY, BECOME A SAFETY HAZARD, OR EXCEED THE STRUCTURAL LOAD CAPABILITIES OF THE BUILDING. COORDINATE REMOVAL WITH APPLICABLE RESTRICTIONS ON ADJACENT RIGHTS OF WAY. 4. CONTRACTOR SHALL LEAVE THE SPACE(S) BROOM CLEAN AND READY TO RECEIVE NEW CONSTRUCTION. 5. IF DIRECTED, SALVAGE ANY ITEMS SPECIFICALLY IDENTIFIED BY THE OWNER/ ARCHITECT OR ENGINEER FOR REUSE. STORE ITEMS IN A PROTECTED LOCATION ON SITE, OR IF DIRECTED PROVIDE LOCAL OFF SITE STORAGE AND LOCAL REDELIVERY AS REQUIRED. 6. CONTRACTOR SHALL COMPLY WITH ALL APPLICABLE LOCAL, STATE AND, FEDERAL CODES, AS WELL AS GOVERNING AUTHORITIES HAVING JURISDICTION. ADHERE TO REGULATIONS PERTAINING TO THE SAFETY OF PERSONS, PROPERTY, AND ENVIRONMENTAL PROTECTION. 7. CONTRACTOR SHALL TAKE NECESSARY PRECAUTIONS TO PREVENT MOVEMENT OR SETTLEMENT OF EXISTING STRUCTURES. PROVIDE AND PLACE BRACING OR SHORING AND BE RESPONSIBLE FOR SAFETY AND SUPPORT STRUCTURES. CONTRACTOR SHALL ASSUME LIABILITY FOR SUCH MOVEMENT, SETTLEMENT DAMAGE OR INJURY RESULTING FROM DEMOLITION WORK. CONTRACTOR SHALL SEEK PROFESSIONAL ADVICE, WHEN NEEDED, IN THE DESIGN AND PLACEMENT OF SUCH SHORING AND BRACING 8. CONTRACTOR SHALL EXERCISE CAUTION WHEN REMOVING CONSTRUCTION WHERE THE EXISTING CONDITIONS ARE UNCLEAR. IN SUCH CASE(S), CONTRACTOR SHALL REMOVE THE NECESSARY CONSTRUCTION TO EXPOSE THE UNDERLYING ELEMENTS PRIOR TO PROCEEDING WITH DEMOLITION. WHENEVER THE REMOVAL OF BUILDING ELEMENTS MAY, OR WILL, CREATE AN UNSTABLE, OR UNSAFE, CONDITION, DO NOT PROCEED WITH DEMOLITION UNTIL THE CONCERN IS REVIEWED BY THE OWNER AND ARCHITECT. AT ANY TIME DURING DEMOLITION, CONTRACTOR SHALL CEASE OPERATIONS IF THE SAFETY OF THE STRUCTURE APPEARS TO BE ENDANGERED. PROVIDE BRACING/SHORING TO STABILIZE STRUCTURE AND IMMEDIATELY CONTACT THE OWNER AND ARCHITECT TO DETERMINE M APPROPRIATE DIRECTION. DO NOT RESUME NORMAL OPERATIONS UNTIL SAFETY IS RESTORED. 9. COORDINATE WITH AND PROVIDE 48 HOURS MINIMUM NOTICE TO OWNER AND BUILDING MANAGEMENT WHEN CUTTING, SHUTTING OFF OR REMOVING COMMUNICATION LINES, WET OR DRY UTILITIES OR OTHER BUILDING SERVICE ELEMENTS. CONTRACTOR SHALL BE RESPONSIBLE FOR MECH., ELEC., PLUMBING REMOVAL AND ABANDONMENT OF THE EXISTING CONSTRUCTION WITHIN THE PROJECT AREA. ELECTRICAL ELEMENTS SHALL BE REMOVED TO NEAREST ACTIVE JUNCTION BOX TO REMAIN. CONTRACTOR SHALL BE ALERT TO SITUATIONS WHERE FIELD CONDITIONS FOR EXISTING M.E.P. OR FIRE PROTECTION SERVICE WOULD RESULT IN A "SERVICE INTERRUPTION" WITH THE REMOVAL OF SAID SERVICE PER DOCUMENTATION. IF THERE IS NO PROVISION TO RETAIN OR REPLACE SERVICE, CONTACT OWNER AND ARCHITECT TO IDENTIFY A SOLUTION. DO NOT PROCEED WITH SERVICE INTERRUPTION UNTIL SUCH TIME. 10. IT IS THE INTENT THAT ALL DEMOLITION WORK ADJACENT TO EXISTING SURFACES THAT SHALL REMAIN TO BE REFINISHED SO AS TO PROVIDE AN EVEN FINISH THAT MATCHES THE ADJACENT SURFACE. IN CASES WHERE REQUIRED DEMOLITION RESULTS IN AN AREA THAT IS NOT SPECIFICALLY IDENTIFIED AS FINISHED/CONCEALED/COVERED, CONTRACTOR SHALL PATCH AND REPAIR SUCH WORK SO THERE IS NO EVIDENCE OF THE DEMOLITION. WHERE DEMOLITION WORK COMPROMISES FIRE RATED CONSTRUCTION, MOISTURENAPOR BARRIERS, OR SIMILAR "CONTAINMENT" CONSTRUCTION. CONTRACTOR SHALL PATCH AND REPAIR CONSTRUCTION TO MAINTAIN THE ORIGINAL BARRIER INTEGRITY. 11. MINIMIZE IMPACT OF DEMOLITION ON ALL ADJACENT SURFACES, FINISHES, AND ACTIVITIES. PROVIDE BARRIER PROTECTIDN (PLYWOOD) OVER ADJACENT SURFACES. THE CONTRACTOR IS RESPONSIBLE FOR ALL REPAIRS TO ADJACENT WORK IF OVER -DEMOLITION OCCURS. 12. IT IS THE INTENTION OF THE KEY NOTES LOCATED ON THE DEMOLITION SHEET(S) TO IDENTIFY CONSTRUCTION ELEMENTS, NOT DESCRIBE ENTIRE ASSEMBLIES. THE REMOVAL OF SAID ELEMENT SHOULD INCLUDE ALL ASSOCIATED CONSTRUCTION (i.e. CERAMIC TILE SHOULD INCLUDE (BUT NOT LIMITED TO) THE TILE, MASTIC GROUT, TERRAllO STRIPS, ETC.) U.N.O. Index of Interior Drawings EXISTING GUESTROOM COUNT Drawing No. Drawing Description ROOMS & ENCLOSED SPACES A-2 (IBC) 2015 B Current Revision Issue Date R-1 (IBC)2015 COVER SHEET C C CLASS A: FLAME SPREAD 0 - 25, SMOKE 0 - 450 CLASS B: FLAME SPREAD 26 - 75, SMOKE 0 - 450 CLASS C: FLAME SPREAD 76 - 200, SMOKE 0 - 450 ] 9. 9. 0 6 08.19.2016 id0.00 INDEX SHEET, GENERAL NOTES KHWN 1BK-B 1 BEDROOM KING - BALCONY [1] 09.19.2016 08.19.2016 id0.01 ACCESSIBILITY NOTES: PUBLIC SPACES 2 KHWN 1 [1 09.19.2016 08.19.2016 id0.02 SITE PLAN, EGRESS PLAN -- 16 KHWN 1BKEAB-B 08.19.2016 id1.01 DEMOLITION PLAN: LOBBY/LODGE - LEVEL 01 -- -- 8 KHWN 08.19.2016 id1.02 DEMOLITION PLAN: LODGE/OFFICES - LEVEL 02 - -- 6 6 08.19.2016 1BKAB-B 1 BEDROOM KING ANGLED BAY - BALCONY -- -- -- 6 6 id4.11 CONSTRUCTION & FiNISH PLAN: LOBBY/ LODGE 1 BEDROOM KING WITH ANGLED BAY AND FIREPLACE -- -- 08.19.2016 id4,12 FURNITURE PLAN: LOBBY/ LODGE 1BKF 1 BEDROOM KING WITH FIREPLACE -- 3 08.19.2016 id4.13 FINISH PLAN: LODGE/OFRCES - LEVEL 02 KMSN 1BDF 1 BEDROOM DOUBLE WITH FIREPLACE -- 08.19.2016 id4.14 REFLECTED CEILING PLAN: LOBBY/LODGE, BOH, HOME OFFICE, & FITNESS CENTER 5 TMSN 1BD 1 BEDROOM DOUBLE 08.19.2016 id4.22 ENLARGED CONSTRUCTION & FINISH PLAN: BOH, SUITE SHOP, PANTRY -- 7 THWN 1BDEAB 08.19.2016 2 -- -- -- 2 THWN 1 BDEAB-B id8.01 INTERIOR DETAILS -- -- -- 3 08.19.2016 Id8.02 OUTDOOR KiTCHEN - . -- -- 2 08.19.2016 id8.03 INTERIOR DETAILS - STONE VENEER 2 BEDROOM KING/DD -- 7 -- 08.19.2016 id8.04 EXTERIOR DETAILS 2BKK 2 BEDROOM KING/KING -- 1 08.19.2016 id8.51 INTERIOR MILLWORK: MW -01 FRONT DESK KTKN AlBKT ACCESSIBLE 1 BEDROOM KING TUB 2 08.19.2016 id8.52 INTERIOR MILLWORK: MW -02 BUSSING STATION, MW -03 GUEST LAUNDRY, EMPLOYEE LOUNGE CABS. 2 NKSQA AND NKSQD Al BKT-B ACCESSIBLE 1 BEDROOM KING TUB - BALCONY 08.19.2016 id8.53 INTERIOR MILLWORK: MW -04 SUiTE SHOP, MW -05 BUSINESS CENTER, MW -06 FRONT DESK SCREEN -- 3 NKSQA AND NKSQD Al BKS 08.19.2016 id8.55 INTERIOR MILLWORK: BUFFET ISLAND -- 1 NKSQE 08.19.2016 id8.56 ELEVATIONS: PUBLIC RESTROOMS - -- -- 1 08.19.2016 Id8.57 PANTRY MILLWORK: MW -06 PERIMETER, MW -08 SHORT WALL, MW -09 ISLAND .66 16 16 08.19.2016 id9.00 EXTERIOR ENTRANCE CANOPIES [1] 09.19.2016 08.19.2016 MO -0 LEGEND, GENERAL NOTES, & INDEX 08.19.2016 M0-1 PROJECT NOTES, TABLE, CALCULATIONS 08.19.2016 MO -2 MECHANICAL SCHEDULE 08.19.2016 M1-0 MAIN BUILDING LEVEL 1 MECHANICAL 08.19.2016 M2-0 MEETING ROOM - BUILDING 1 LEVEL 2 MECHANICAL PLAN 08.19.2016 M4-0 DETAILS 08.19.2016 E0-0 LEGEND, NOTES, & DRAWING INDE( 08.19.2016 El -0 MAIN BUILDING LEVEL 1 LIGHTING 08.19.2016 El -1 LIGHTING COMPLIANCE ENERGY FORMS 08.19.2016 E2-0 MAIN BUILDING LEVEL 1 POWER 08.19.2016 E2-1 BUILDING 1 LEVEL 2 POWER 08.19.2016 E3-0 LIGHTING FUNCTIONAL TESTING & SCHEDULES 08.19.2016 P0-0 LEGEND, GENERAL NOTES, & INDIX�''U /` 08.19.2016 P0-1 SCHEDULE, PROJECT NOTESb 1 023 �"' r �� 08.19.2016 P1-0 LEVEL 1 PLUMBING PLAN ,� ' 08.19.2016 P2-0 DETAILS 08.19.2016 Project Scope: PROJECT DESCRIPTION: THIS PROJECT WILL CONSIST OF AN INTERIOR FINISHES AND FF&E (FURNITURE, FXTURES & EQUIPMENT) RENOVATION OF AN EXISTING HOMEWOOD SUITES HOTEL LOCATED WITHIN THE CITY OF TUKWILA, WASHINGTON. THE HOTEL IS COMPOSED OF 1 MAIN BUILDING AND 4 GUESTROOM BUILDINGS WITH A TOTAL OF 106 GUESTROOMS. THE RENOVATION WILL INCLUDE THE EXISTING LOBBY/LODGE, BUSINESS CENTER, MEETING ROOM, CORRIDORS, GUEST LAUNDRY, ELEVATOR LOBBIES, AND POOL AREA TO RECEIVE NEW FINISHES AND FURNITURE; WITHIN THE DESIGNATED AREAS IN THIS DRAWING SET. BOH AND EMPLOYEE BREAKROOM INCLUDES NEW LAYOUT, FINISHES AND MILLWORK. ALL GUESTROOMS TO RECEIVE NEW FURNITURE, FINISHES AND MILLWORK. NO MODIFICATIONS TO THE BUILDING STRUCTURE, BUILDING ENVELOPE, SITE OR EXITING WILL OCCUR. MODIFICATIONS TO LIFE SAFETY SYSTEMS (ALARMS & SPRINKLERS) SHOULD NOT BE MINIMAL IF NECESSARY. ELECTRICAL WORK INDICATED WITHIN THESE DOCUMENTS IS FOR THE PURPOSE OF IDENTIFYING SCOPE. ELECTRICAL WORK SHALL BE EXECUTED AS A 'DESIGN -BUILD' CONTRACT WITH THE CONTRACTORS APPLYING FOR TRADE PERMITS. BUILDING CODE INFORMATION: BUILDING CODES (WITH STATEWIDE AMENDMENTS): 2015 INTERNATIONAL BUILDING CODE 2015 ICC/ANSI A117.1-09 2015 INTERNATIONAL MECHANICAL CODE 2015 UNIFORM PLUMBING CODE 2015 WASHINGTON STATE ENERGY CODE 2014 NFPA 70 OCCUPANCY: MIXED OCCUPANCY NON -SEPARATED MIXED USE GROUPS A-2 (LOBBY) A-4 (POOL AREA) CONSTRUCTION TYPE: TYPE VA NON-COMBUSTABLE (EXISTING) --AS CAN BE DETERMINED BY THE VISIBLE COMPONENTS OF CONSIRUCTIONAND IN THE ARCHITECTS PROFESSIONAL OPINION. FIRE SUPPRESSION: FULLY SPRINKLERED (EXISTING) MATERIALS: ALL COMBUSTIBLE MATERIALS LOCATED WITHIN FIRE RATED NON-BEARING CONSTRUCTION SHALL BE FIRE RETARDANT TREATED WOOD AND NOT PERMITTED IN ANY LOAD BEARING ASSEMBLY OR AN ASSEMBLY WITH A FIRE RATING MORE THAN 2 HOURS INTERIOR FINISH REQUIREMENTS: MINIMUM FLAME SPREAD CLASS REQUIREMENTS FULLY SPRINKLERED EXISTING GUESTROOM COUNT VERTICAL EXITS & EXIT PASSAGEWAYS EXIT ACCESS & OTHER EXITWAYS ROOMS & ENCLOSED SPACES A-2 (IBC) 2015 B B C R-1 (IBC)2015 B. C C CLASS A: FLAME SPREAD 0 - 25, SMOKE 0 - 450 CLASS B: FLAME SPREAD 26 - 75, SMOKE 0 - 450 CLASS C: FLAME SPREAD 76 - 200, SMOKE 0 - 450 1. 2. 4. 5. 6. 7. 8. 9. 10. ALL FINISHES FOR THIS PROJECT ARE CLASS 'A' OR BETTER (NON-COMBUSTABLE) ALL WOOD TRIM AND WOOD BLOCKING TO BE 'FLAME RESISTANCE TREATED" TO RESIST THE SPREAD OF FLAME IN ACCORDANCE WITH NFPA 701. ALL FABRIC TO BE "FIRE RETARDANT TREATED". ALL GLASS PERTAINING TO INTERIOR DESIGN TO BE LAMINATED OR TEMPERED SAFETY GLASS. CARPETING: FLAME RETARDANT RATING (CLASS 1 FLAME SPREAD SMOKE GENERATING RATING <450 SMOKE GENERATION) "PILL TEST" AND WATT/SF. FLOOR FINISHES: FINISHES OTHER THAN WOOD, VINYL, LINOLEUM, TERRAllO, AND RESILIENT FLOOR COVERING SHALL PASS DOC FF -1 "PILL TEST" (CPSC 16 CRF: 1630) MINIMUM CRITICAL RADIANT FLUX OF 0.04 WATTS/CM. ALL FLOOR FINISHES ON LEVEL SURFACES SHALL HAVE A SLIP RESISTANCE (COEFFICIENT OF FRICTION) OF 0.60. ALL FLOOR FINISHES ON A RAMP SHALL HAVE A SLIP RESISTANCE OF 0.80. WALL & CEILING MATERIALS: ALL WALL CEILING FINISH MATERIALS SHALL BE MINIMUM CLASS B (ASTM E-84) FLAME SPREAD OF 26-75; AND SMOKE -DEVELOPED RATING OF 0-450. DECORATIVE MATERIALS: (CURTAINS, DRAPERIES, ETC): SHALL CONSIST OF FLAME -RESISTANT MATERIALS (NFPA 701). COMBUSTIBLE MATERIALS MAY BE FURRED OUT FROM FACE OF NON-COMBUSTABLE SUBSTRATE PROVIDED THAT THE RESULTING CAVITY IS EITHER FILLED WITH AN INORGANIC OR NON-COMBUSTABLE FILL MATERIAL OR FIRE BLOCKED AT 8'-0" IN ALL DIRECTIONS RECEIVE ITY OF TUKWILA SEP 2 0 2016 PERMIT CENTER REVIEWED FOR CODE COMPLIANCE APPROVED OCT 252016 City of Tukwila BUILDING DIVISION 1 5 8 10 11 12. 13 14 HOMEWOOD SUITES BY HILTON" Seattle/Tukwila, WA Inn Code: SEATK EXISTING GUESTROOM COUNT ROOM TYPE: BUILDING: 1 2 3 4 TOTAL HOTEL ROOM TYPE ISSUED INFORMATION OWNER REVIEW SET: BRAND REVIEW SET: 28 April 2016 ISSUED: 19 August 2016 REVISIONS: BLDG. DEPT. COMMENTS 09.19.16 DESIGNATION 1BK 1 BEDROOM KING 21 -- -- -- 21 KHWN 1BK-B 1 BEDROOM KING - BALCONY 2 -- -- -- 2 KHWN 1BKEAB 1 BEDROOM KING EXTENDED ANGLED BAY 16 -- -- -- 16 KHWN 1BKEAB-B 1 BEDROOM KING EXTENDED ANGLED BAY - BALCONY 8 -- -- -- 8 KHWN 1BKAB 1 BEDROOM KING ANGLED BAY -- - -- 6 6 KHWN 1BKAB-B 1 BEDROOM KING ANGLED BAY - BALCONY -- -- -- 6 6 KHWN 1BKABF 1 BEDROOM KING WITH ANGLED BAY AND FIREPLACE -- -- 2 2 KMSN 1BKF 1 BEDROOM KING WITH FIREPLACE -- 3 8 -- 11 KMSN 1BDF 1 BEDROOM DOUBLE WITH FIREPLACE -- 5 -- -- 5 TMSN 1BD 1 BEDROOM DOUBLE 7 -- -- -- 7 THWN 1BDEAB 1 BEDROOM DOUBLE EXTENDED ANGLED BAY 2 -- -- -- 2 THWN 1 BDEAB-B 1 BEDROOM DOUBLE EXTENDED ANGLED BAY - BALCONY 3 -- -- -- 3 THWN 1BDAB 1 BEDROOM DOUBLE ANGLED BAY - . -- -- 2 2 THWN 2BKD 2 BEDROOM KING/DD -- 7 -- -- 7 KTDN 2BKK 2 BEDROOM KING/KING -- 1 -- -- 1 KTKN AlBKT ACCESSIBLE 1 BEDROOM KING TUB 2 -- -- -- 2 NKSQA AND NKSQD Al BKT-B ACCESSIBLE 1 BEDROOM KING TUB - BALCONY 3 -- 3 NKSQA AND NKSQD Al BKS ACCESSIBLE 1 BEDROOM KING ROLL IN SHOWER 1 -- -- 1 NKSQE Al BDS ACCESSIBLE 1 BEDROOM DOUBLE ROLL IN SHOWER 1 - -- -- 1 NDSQE TOTAL GUESTROOMS: .66 16 8 16 106 RECEIVE ITY OF TUKWILA SEP 2 0 2016 PERMIT CENTER REVIEWED FOR CODE COMPLIANCE APPROVED OCT 252016 City of Tukwila BUILDING DIVISION 1 5 8 10 11 12. 13 14 HOMEWOOD SUITES BY HILTON" Seattle/Tukwila, WA Inn Code: SEATK FRC DESIGN WORLDWIDE 311 Elm Street Suite 600 Cincinnati, OH 45202 www.FRCH.com 513 2413000 Owner 804.727.1757 Apple Hospitality REIT, Inc. 814 East Main Street Richmond, VA 23219 Chris Zeigler Architect 513.241.3000 FRCH Design Worldwide f: 513.241.5015 311 Elm Street, Suite 600 Cincinnati, OH 45202-2706 Mike Keifling Interior Design 513.241.3000 FRCH Design Worldwide f: 513.241.5015 311 Elm Street, Suite 600 Cincinnati, OH 45202-2706 Raejean Downs ISSUED INFORMATION OWNER REVIEW SET: BRAND REVIEW SET: 28 April 2016 ISSUED: 19 August 2016 REVISIONS: BLDG. DEPT. COMMENTS 09.19.16 FRCH 1 ARCHITECTURE, INC., P.C. rz!\; Eal . ER'4a, ECT {I J AMES DE ST4TEOF Hyl S ETON va CI' ICI' Z.cr� PROJECT INFORMATION INTERIOR & EXTERIOR RENOVATION Homewood Suites Tukwila 6955 Fort Dent Way Tukwila, WA 98188-2554 PROJECT NUMBER: 032609.000 SHEET INFORMATION Index Sheet, General Notes DRAWN BY: A. Cunningham REVIEWED BY: M.Keifling, R.Downs SCALE: As Noted AUTHORIZED FOR: PERMIT • Accessible_Vanity/Lavatory Section 6. Accessible Fixture Clearances (Public Spaces) W o tMIME GENERAL REQUIREMENTS: 5'-0" MIN. 2'-0" 1'-6" 2'-1" COCA C' 7' FLUSH CONTROLS MUST BE LOCATED ON THE OPEN SIDE OF THE FIXTURE 1'-5" TOILET CLEARANCE MIN. COUNTERTOP COD I / 16"-181. . +34" MAX di a� O . — LAVATORY RIM OR COUNTER SURFACE MUST BE NO 1. i / 4 r +29" MIN di v _ ( ✓ r—\ ties (Publ HIGHER THAN 34" AFF ♦ • O A, A.F.F. A ` ,• ! / / INSULATE ALL PIPES TO PREVENT CONTACT. 'CLEAR MAINTAIN ACCESSIBLE ENVELOPE / AS REPRESENTED BY SHADED AREA t ' DO NOT BUILD IN SHADED AREA. THIS IS fr� MAX./FOR REFERENCE ONLY. +9" MINdi A r 7 '...REFER ..n ...; ..... TO VANITY/LAVATORY ACCESSIBILITY DIMENSIONS ARE SHOWN IN INCHES AND WITH OA CD F, 4 PULL SIDE r HINGE -SIDE APPROACH V1: DOOR + 42" NO MORE THAN 1) BOWL OR SINK SHALL BE REQUIRED TO PROVIDE KNEE AND TOE CLEARANCES HAND -OPERATED (TOUCHLESS) METERING FAUCETS SHALL z z z z 1 I ��— I SECTION FOR ADDITIONAL CLEARANCE REQUIREMENTS At All Accessible Bath Facili REMAIN OPEN FOR 10 SECONDS MINIMUM c9 1 B 'r— 1 WATER SUPPLY AND DRAIN PIPES UNDER LAVATORIES AND ,, ¢ " ♦ SINKS SHALL BE INSULATED OR OTHERWISE CONFIGURED o TO PROTECT AGAINST CONTACT. THERE SHALL BE NO . r SHARP OR ABRASIVE SURFACES UNDER LAVATORIES AND 4 SINKS go o ~ 5 io - —I °C I z I j 30x48 LAVATORY I� I I 1 REFER TO SHEET id0.02 FOR FIXTURE/ACCESSSORY L =1/7/7 _Az 0vV1 CLEARANCE ______ J MOUNTING HEIGHTS ♦ ,rri '. 3i' ed'r1 i r___ REFER TO MANEUVERABILITY REQUIREMENTS THIS SHEET FOR DOOR CLEARANCE REQUIREMENTS DOORS MAY NOT SWING INTO CLEARANCES REQUIRED FOR ANY FIXTURE, BUT MAY SWING INTO REQUIRED TURNING ♦ ♦ 3 P t .:: 3 4 x r z ..X � 1 + . r �.l .,t � � L eM,. ,. .:.c� J RADIUS / / 0 < < i°0— o >»> OVER OBSTRUCTION OVER OBSTRUCTION DE APPROACH NO LESS THAN 2) DRINKING FOUNTAINS ARE REQUIRED - n. r ON LOW FOR WHEELCHAIR ACCESSIBILITY AND ONE HIGH I 5'-0" 1 1 FOR PERSONS WITH BENDING OR STOOPING DISABILITIES RESTROOM ACCESSIBLE STALL CLEARANCES cu 42° CC 40" Al ADDITIONAL CLEAR FLOOR AREA REQUIRED WHEN DOOR HAS BOTH CLOSER AND A LATCH 0 ADDITIONAL CLEAR FLOOR AREA REQUIRED WHEN DOOR HAS CLOSER OA3 ALTERNATIVE CLEAR FLOOR AREAS BASED ON APPROACH CLEARANCES 36" EACH DOOR OPERATING OF 90° OPEN CONTRACTOR(S) (ALUMN. "OPENING" FORCE IS 5lbs OR To 12° FROM LATCH (CLOSING) J STOREFRONT/WOOD/HOLLOW METAL) SHALL BE RESPONSIBLE To ADJUST ALL INTERIOR DOORS SO THAT THE DOOR'S REQUIRED CONTINUOUS LESS. ANY DOOR WITH A CLOSER SHALL BE ADJUSTED To SLOW THE CLOSING TIME To A MINIMUM OF FIVE SECS. FROM A STARTING POINT -- REFER To DIAGRAM BELOW: fQ. VARIES 90° d cn 127 12° I.— 12"HOLD n 12" n , I NOTE: c jG� Cal � E. '. OI MAXIMUM ;77 , 7 / / //-7,17 / / _,_ , � �� /////, 4 , / 3.. 0 / 2015 IBC/ANSI 117.1-2009 REQUIREMENT 7 7 / / 1 T ■ /e///,/,,////,0„z /0/ /�//,7, Mounting Heights � 1m y..e, j .,( / 1-1-I 21-0" 10" j, ,,,,f,/ 10" 41: OVER OBSTRUCTION OVER OBSTRUCTION OVER OBSTRUCTION ALL VENDING MACHINES MUST COMPLY WITH THE ALL FOOD/BEVERAGE ITEMS, CONTROLS, BUTTONS, LEVERS, ALL WALL MOUNTED DEVICES, ELECTRICAL DEVICES, FOLLOWING ACCESSIBLE REACH RANGE REQUIREMENTS: DISPENSERS, HANDLES, ETC. OR OTHER EQUIPMENT PROVIDED PHONES, INTERCOM BUTTONS, ELEVATOR CALL BUTTONS, - ALL COIN SLOTS, DOLLAR CHANGERS, LEVERS, BUTTONS,FORUSE BY GUESTS MUSTBE S S MOUNTED OR LOCATED ON ETC. PROVIDED FOR GUEST USE MUST HAVE ALL BUTTONS, CONTROLS, ACCESS DOORS, ETC. SHALL BE NO LOWER WORK SURFACES, COUNTERTOPS, MILLWORK, CONSOLE CONTROLS, LEVERS, ETC. TO BE WITHIN ACCESSIBLE THAN 15" AFF AND NO HIGHER THAN 48" AFF. TABLES, ETC. NO GREATER THAN 24" FROM THE FRONT FACE REACH RANGES PER THE DIAGRAMS BELOW - MACHINES MUST BE INSTALLED FOR FINAL INSPECTIONS. OF THE CABINETRY AND NO HIGHER THAN 46" AFF .1�C ewe... ... ,.,L ✓. _ ..., 5 Tji31/2'MIN" GRAB BAR TOILET GRAB BAR . 18” GRAB BAR URINAL SURFACE MTD. SEAT HEIGHT (ACCESSIBILITY) HOLD (VERTICAL) GRAB BAR OUTSIDE DIAMETER SHALL BE 1 1/4" MINIMUM AND 2" NOTE: , SURFACE MTD. NOTE: SURFACE MTD. MAXIMUM TYPICAL CLEAR AREA AROUND GRAB BARS TO BE: ABOVE - 12" , BELOW - 1.5". BETWEEN, SHOWER CONTROLS, SHOWER FITTING, AND OTHER GRAB BARS A CLEAR DISTANCE OF 1.5" IS PERMITTED fir. ALL EQUIPMENT CONTROLS OR PRODUCT DISPENSER LOCATIONS MUST BE WITHIN REACH RANGE AS SHOWN ----®- • cn. ° 3.1/4--1, , / / 7 ^:;/,7,77,7,/, cc> '7 / z/z/ v/z/ .., /7 7/ 4 - / / ii/ / c / pv7777 7 7:/„.,w W oz 1%/ /' °' a /, ,° . UNDERSIDE OF `//, / �� VANITY SKIRT / / �� /'� �` d`./ , / 2 g/ ///.//, ,r ,;, / /� / 48" A.F.F. MA) / a c.) 7 / / //A Z' / ' //:/// !� '1/1 io..!✓..' M N ZL.a' .�:......L..�.,.�! ... S`. M to = N Jd Y Z . .µw..✓.:, - Ste. m ao aA ..a.. .....C...a...GL Iy ....t. .> �_ CC G ...2/'F/. �, m c,. , ,. .9' M d— TO REFLECTIVE SURFACE M r ao .r.• ef' r .-. ep 711.911 `f. 7A ♦ • ♦ 4 TOILET PAPER ROLL HOLDER ♦ DUAL TOILET TOILET TISSUE PAPER HOLDER DISPENSER ♦ ♦ 1 MIRROR SAN. NAPKIN TOWEL DISP. / SANITARY TOWEL HOOK NAPKIN DISPOSAL DISPENSER WASTE RECEP. . SURFACE MOUNTED RECESSED RECESSED RECESSED MTD. Accessible_Vanity/Lavatory Section 6. inimum Clear Floor Areas c� W o tMIME FRONT APPROACH HINGE -SIDE APPROACH LATCH -SIDE APPROACH 4'-61(54") DOOR + 24" co) 2'-0" INSTALL BOTTOM OF MIRROR (NOT FRAME) SO THE BOTTOM OF THE REFLECTIVE SURFACE IS NOT ABOVE 40" 2'-1" J REVISIONS: BLDG. DEPT. COMMENTS 0919.16 AF.F. PER ACCESSIBILITY REQUIREMENTS) COUNTERTOP -.` I FRCH 1 ARCHITECTURE, INC., P.C. . +34" MAX di a� O 0 t P4 1. i / 4 r +29" MIN di v _ ( ✓ r—\ A.F.F. OA +27" MIN coa: v < < o v. co O A, A.F.F. A ,• ! / / INSULATE ALL PIPES TO PREVENT CONTACT. 'CLEAR MAINTAIN ACCESSIBLE ENVELOPE / AS REPRESENTED BY SHADED AREA t ' DO NOT BUILD IN SHADED AREA. THIS IS fr� MAX./FOR REFERENCE ONLY. +9" MINdi A r A.F.F. G- (m.. ..n ...; ..... ACCESSIBILITY DIMENSIONS ARE SHOWN IN INCHES AND WITH OA CD Accessible Swing -Door inimum Clear Floor Areas c� W o tMIME FRONT APPROACH HINGE -SIDE APPROACH LATCH -SIDE APPROACH 4'-61(54") DOOR + 24" co) �11-0 1•�%%/%%1%%�/ 2'-1" ISSUED: 19 August 2016 REVISIONS: BLDG. DEPT. COMMENTS 0919.16 ofIC O -.` FRCH 1 ARCHITECTURE, INC., P.C. . GfSTi STAp N ' FONG TT�ON W"HING... bet i11• a� ;: %%//T//T/T/ FE 0 , • / 4 r DRAWN BY: M. Keifling REVIEWED BY: M. Keifling SCALE: As Noted v v c,, coa: v < < o v. co >>iii> CD F, 4 PULL SIDE FRONT APPROACH HINGE -SIDE APPROACH V1: DOOR + 42" LATCH -SIDE APPROACH V2: DOOR + 36" DOOR + 24" 'r— xx hoi 111•Li.malZ1 —♦ AV2 V2: 5'-0" (60") V1: 4'-6" (54") =1/7/7 _Az 0vV1 1S. .�4 A ;; r,.t k'„.• ,rri '. 3i' ed'r1 i r___ k � .`u u f 4 '. t ) 'fi'iiu`fr y t 5,.,✓ r: r. ♦ 3 P t .:: 3 4 x r z ..X � 1 + . r �.l .,t � � L eM,. ,. .:.c� Ft, 6 / / 0 < < i°0— o >»> OVER OBSTRUCTION OVER OBSTRUCTION DE APPROACH (18") 1 1 Al ADDITIONAL CLEAR FLOOR AREA REQUIRED WHEN DOOR HAS BOTH CLOSER AND A LATCH 0 ADDITIONAL CLEAR FLOOR AREA REQUIRED WHEN DOOR HAS CLOSER OA3 ALTERNATIVE CLEAR FLOOR AREAS BASED ON APPROACH CLEARANCES CLOSER EACH DOOR OPERATING OF 90° OPEN CONTRACTOR(S) (ALUMN. "OPENING" FORCE IS 5lbs OR To 12° FROM LATCH (CLOSING) J STOREFRONT/WOOD/HOLLOW METAL) SHALL BE RESPONSIBLE To ADJUST ALL INTERIOR DOORS SO THAT THE DOOR'S REQUIRED CONTINUOUS LESS. ANY DOOR WITH A CLOSER SHALL BE ADJUSTED To SLOW THE CLOSING TIME To A MINIMUM OF FIVE SECS. FROM A STARTING POINT -- REFER To DIAGRAM BELOW: 90° d cn 127 12° I.— = _ c jG� Code Notes:6 SHEETS id0.01 ARE TO BE USED TO VERIFY ACCESSIBILITYFORALLEXISTING IXI TING FEATURES LOCATED IN THE LOBBY INCLUDING ALL EXISTING FEATURES ALONG THE ACCESSIBLE ROUTE TO THE LOBBY AND RESTROOMS, DRINKING FOUNTAINS AND TELEPHONES SERVING THE EXISTING LOBBY SPACE. THE DESIGN INTENT OF THESE DRAWINGS ARE DETAILED IN SUCH A MANNER AS TO ENSURE ACCESSIBILITY COMPLIANCE FOR ALL NEW FEATURES TO BE INCORPORATED INTO THE ALTERATION. THESE SHEETS INDICATE REQUIREMENTS THAT MAY BE BEYOND OUR SCOPE, BUT ARE STILL A REQUIREMENT FOR FULL AND STRICT COMPLIANCE PER 2015 INTERNATIONAL BUILDING CODE, 2015 WASHINGTON STATE BUILDING CODE (IBC WITH STATE AMENDMENTS) AND 2009 ANSI 117.1-09. THE DRAWINGS AND DIAGRAMS DEPICTED ON SHEETS id0.01 ARE THE MINIMUM REQUIREMENTS FOR COMPLIANCE WITH FEDERAL MANDATES AND STATE AND LOCAL BUILDING CODES. THEY DO NOT REPRESENT ALL APPLICABLE STANDARDS AND REQUIREMENTS FOR FULL COMPLIANCE ATA PROPERTY, BUT ARE INTENDED TO ASSIST OWNER/GC TO VERIFY EXISTING PROPERTY CONDITIONS AND DETERMINE IF ELEMENTS ARE IN COMPLIANCE OR NEED ADDITIONAL INFORMATION TO BRING ITEMS INTO COMPLIANCE AS REQUIRED BY ABOVE STATED CODE/MANDATES. THE ARCHITECT HAS ENDEAVORED TOP PROVIDE E ADDITIONAL CLEARANCE IN EXCESS OF THE REQUIRED MINIMUMS TO ACCOMMODATE CONSTRUCTION TOLERANCES. WHERE DIMENSIONAL RANGES WERE REFERENCED BY THE ACCESSIBILITY STANDARD, A SINGLE 'MIDDLE VALUE' WAS PROVIDED TO ACCOMMODATE CONSTRUCTION TOLERANCES TO HELP EACH CONTRACTOR UNDERSTAND WHAT IS CRITICAL FOR ACCESSIBILITY, ADDITIONAL INFORMATION HAS BEEN ADDED TO THE DRAWINGS. • CLEAR FLOOR AREA - THIS IS THE AREA REQUIRED AROUND AN OBJECT OR DOOR (PLEASE NOTE DOORS ARE NOT INDICATED ON MOST PLANS BUT THAT INFORMATION IS INDICATED ON THIS SHEET IN THE 'ACCESSIBLE SWING -DOOR MINIMUM CLEAR FLOOR AREA' SECTION. CLEAR FLOOR AREAS AT PLUMBING FIXTURES ARE INDICATED AS SUCH WHERE THE FIXTURE IS LABELED AND THE REQUIRED CLEAR FLOOR AREA IS IDENTIFIED IN INCHES. UNLESS INDICATED OTHERWISE, THE CLEAR FLOOR AREA IS CENTERED ON PLUMBING FIXTURE. ILAVATORY 30"x48" L J •• IT IS EACH CONTRACTOR'S RESPONSIBILITY TO KNOW THE LAYOUT DIMENSIONS INDICATED IN THE ICC/ANSI A117.1-2009. IF THE PUBLISHED ADA STANDARDS USE A DIMENSION RANGE, THE OBJECT MUST BE WITHIN THAT RANGE. IF IT'S A MAXIMUM DIMENSION, DON'T BE BIGGER, IF IT ISA MINIMUM DIMENSION DONT BE LESS. LOBBY RENOVATIONS 2015 IBC/ANSI 117.1-2009 (SECTION 3409.6 ALTERATIONS AFFECTING AN AREA CONTAINING A PRIMARY FUNCTION) WHEN AN ALTERATION AFFECTS CCESS THE H ACCESSIBILITY TO , OR CONTAINS AN AREA OF PRIMARY FUNCTION, THE ROUTE TO THE PRIMARY FUNCTION AREA SHALL BE ACCESSIBLE. THE ACCESSIBLE ROUTE TO THE PRIMARY FUNCTION AREA SHALL INCLUDE TOILET FACILITIES OR DRINKING FOUNTAINS SERVING THE AREA OF PRIMARY FUNCTION COMPLIANCE MUST INCLUDE: -PATH OF TRAVEL TO PRIMARY FUNCTION SPACE -RESTROOMS SERVING PRIMARY FUNCTION -DRINKING FOUNTAINS SERVING PRIMARY FUNCTION TELEPHONES (WHERE PROVIDED) SERVING PRIMARY FUNCTION -ALL SIGNAGE NT AL • VIC _ ! NT DELETED ACCESSIBLE DINING REQUIRED ACCESSIBLE SEATING = 5% OF TOTAL DINING SEATING TOTAL SEAT COUNT = <50 ACCESSIBLE SEAT COUNT (x.05) = 2 TOTAL SEAT COUNT = >50-60 ACCESSIBLE SEAT COUNT (x.05) = 3 RECEIVED CITY OF TUKWILA SEP 2 0 2016 PERMIT CENTER c Bl HOMEWOOD SITES BY HILTON" Seattle/Tukwila, WA Inn Code: SEATK Accessible Reach Ranges: Owner 804.727.1757 Apple Hospitality REIT, Inc. 814 East Main Street Richmond, VA 23219 Chris Zeigler Architect 513.241.3000 FRCH/Architecture, Inc., P.C. f: 513.241.5015 311 Elm Street, Suite 600 Cincinnati, OH 45202-2706 Mike Keifling Interior Design 513.241.3000 FRCH Design Worldwide f: 513,241.5015 311 Elm Street, Suite 600 Cincinnati, OH 45202-2706 Raejean Downs 11-8" OWNER REVIEW SET: 2'-1" ISSUED: 19 August 2016 REVISIONS: BLDG. DEPT. COMMENTS 0919.16 ofIC O FRCH 1 ARCHITECTURE, INC., P.C. 10520. JAMES DEN STATE OF GfSTi STAp N ' FONG TT�ON W"HING... bet i11• PROJECT INFORMATION O. PROJECT NUMBER: 032609.000 , INFORMATION 'ED FOR viPLIANC OVED P 5 2016 tukwila DIVISION r DRAWN BY: M. Keifling REVIEWED BY: M. Keifling SCALE: As Noted AUTHORIZED FOR: PERMIT id0a0 CD F, 4 G CC E. xx hoi 111•Li.malZ1 V _Arm �V 1S. .�4 A ;; r,.t k'„.• .GY p d ':� , y; '.:k5 r ,, h.,,, .tom,. £., �k ,'$�"` d' ,".'. ,,.. '. 3i' ed'r1 k � .`u u f 4 '. t ) 'fi'iiu`fr y t 5,.,✓ r: r. ♦ 3 P t .:: 3 4 x r z ..X � 1 + . r �.l .,t � � L eM,. ,. .:.c� v#. UNOBSTRUCTED OVER OBSTRUCTION OVER OBSTRUCTION DE APPROACH c jG� � E. '. OI MAXIMUM } h G v S 4 A 1 T ■ 21-0" 10" j, 10" 41: OVER OBSTRUCTION OVER OBSTRUCTION OVER OBSTRUCTION ALL VENDING MACHINES MUST COMPLY WITH THE ALL FOOD/BEVERAGE ITEMS, CONTROLS, BUTTONS, LEVERS, ALL WALL MOUNTED DEVICES, ELECTRICAL DEVICES, FOLLOWING ACCESSIBLE REACH RANGE REQUIREMENTS: DISPENSERS, HANDLES, ETC. OR OTHER EQUIPMENT PROVIDED PHONES, INTERCOM BUTTONS, ELEVATOR CALL BUTTONS, - ALL COIN SLOTS, DOLLAR CHANGERS, LEVERS, BUTTONS,FORUSE BY GUESTS MUSTBE S S MOUNTED OR LOCATED ON ETC. PROVIDED FOR GUEST USE MUST HAVE ALL BUTTONS, CONTROLS, ACCESS DOORS, ETC. SHALL BE NO LOWER WORK SURFACES, COUNTERTOPS, MILLWORK, CONSOLE CONTROLS, LEVERS, ETC. TO BE WITHIN ACCESSIBLE THAN 15" AFF AND NO HIGHER THAN 48" AFF. TABLES, ETC. NO GREATER THAN 24" FROM THE FRONT FACE REACH RANGES PER THE DIAGRAMS BELOW - MACHINES MUST BE INSTALLED FOR FINAL INSPECTIONS. OF THE CABINETRY AND NO HIGHER THAN 46" AFF Code Notes:6 SHEETS id0.01 ARE TO BE USED TO VERIFY ACCESSIBILITYFORALLEXISTING IXI TING FEATURES LOCATED IN THE LOBBY INCLUDING ALL EXISTING FEATURES ALONG THE ACCESSIBLE ROUTE TO THE LOBBY AND RESTROOMS, DRINKING FOUNTAINS AND TELEPHONES SERVING THE EXISTING LOBBY SPACE. THE DESIGN INTENT OF THESE DRAWINGS ARE DETAILED IN SUCH A MANNER AS TO ENSURE ACCESSIBILITY COMPLIANCE FOR ALL NEW FEATURES TO BE INCORPORATED INTO THE ALTERATION. THESE SHEETS INDICATE REQUIREMENTS THAT MAY BE BEYOND OUR SCOPE, BUT ARE STILL A REQUIREMENT FOR FULL AND STRICT COMPLIANCE PER 2015 INTERNATIONAL BUILDING CODE, 2015 WASHINGTON STATE BUILDING CODE (IBC WITH STATE AMENDMENTS) AND 2009 ANSI 117.1-09. THE DRAWINGS AND DIAGRAMS DEPICTED ON SHEETS id0.01 ARE THE MINIMUM REQUIREMENTS FOR COMPLIANCE WITH FEDERAL MANDATES AND STATE AND LOCAL BUILDING CODES. THEY DO NOT REPRESENT ALL APPLICABLE STANDARDS AND REQUIREMENTS FOR FULL COMPLIANCE ATA PROPERTY, BUT ARE INTENDED TO ASSIST OWNER/GC TO VERIFY EXISTING PROPERTY CONDITIONS AND DETERMINE IF ELEMENTS ARE IN COMPLIANCE OR NEED ADDITIONAL INFORMATION TO BRING ITEMS INTO COMPLIANCE AS REQUIRED BY ABOVE STATED CODE/MANDATES. THE ARCHITECT HAS ENDEAVORED TOP PROVIDE E ADDITIONAL CLEARANCE IN EXCESS OF THE REQUIRED MINIMUMS TO ACCOMMODATE CONSTRUCTION TOLERANCES. WHERE DIMENSIONAL RANGES WERE REFERENCED BY THE ACCESSIBILITY STANDARD, A SINGLE 'MIDDLE VALUE' WAS PROVIDED TO ACCOMMODATE CONSTRUCTION TOLERANCES TO HELP EACH CONTRACTOR UNDERSTAND WHAT IS CRITICAL FOR ACCESSIBILITY, ADDITIONAL INFORMATION HAS BEEN ADDED TO THE DRAWINGS. • CLEAR FLOOR AREA - THIS IS THE AREA REQUIRED AROUND AN OBJECT OR DOOR (PLEASE NOTE DOORS ARE NOT INDICATED ON MOST PLANS BUT THAT INFORMATION IS INDICATED ON THIS SHEET IN THE 'ACCESSIBLE SWING -DOOR MINIMUM CLEAR FLOOR AREA' SECTION. CLEAR FLOOR AREAS AT PLUMBING FIXTURES ARE INDICATED AS SUCH WHERE THE FIXTURE IS LABELED AND THE REQUIRED CLEAR FLOOR AREA IS IDENTIFIED IN INCHES. UNLESS INDICATED OTHERWISE, THE CLEAR FLOOR AREA IS CENTERED ON PLUMBING FIXTURE. ILAVATORY 30"x48" L J •• IT IS EACH CONTRACTOR'S RESPONSIBILITY TO KNOW THE LAYOUT DIMENSIONS INDICATED IN THE ICC/ANSI A117.1-2009. IF THE PUBLISHED ADA STANDARDS USE A DIMENSION RANGE, THE OBJECT MUST BE WITHIN THAT RANGE. IF IT'S A MAXIMUM DIMENSION, DON'T BE BIGGER, IF IT ISA MINIMUM DIMENSION DONT BE LESS. LOBBY RENOVATIONS 2015 IBC/ANSI 117.1-2009 (SECTION 3409.6 ALTERATIONS AFFECTING AN AREA CONTAINING A PRIMARY FUNCTION) WHEN AN ALTERATION AFFECTS CCESS THE H ACCESSIBILITY TO , OR CONTAINS AN AREA OF PRIMARY FUNCTION, THE ROUTE TO THE PRIMARY FUNCTION AREA SHALL BE ACCESSIBLE. THE ACCESSIBLE ROUTE TO THE PRIMARY FUNCTION AREA SHALL INCLUDE TOILET FACILITIES OR DRINKING FOUNTAINS SERVING THE AREA OF PRIMARY FUNCTION COMPLIANCE MUST INCLUDE: -PATH OF TRAVEL TO PRIMARY FUNCTION SPACE -RESTROOMS SERVING PRIMARY FUNCTION -DRINKING FOUNTAINS SERVING PRIMARY FUNCTION TELEPHONES (WHERE PROVIDED) SERVING PRIMARY FUNCTION -ALL SIGNAGE NT AL • VIC _ ! NT DELETED ACCESSIBLE DINING REQUIRED ACCESSIBLE SEATING = 5% OF TOTAL DINING SEATING TOTAL SEAT COUNT = <50 ACCESSIBLE SEAT COUNT (x.05) = 2 TOTAL SEAT COUNT = >50-60 ACCESSIBLE SEAT COUNT (x.05) = 3 RECEIVED CITY OF TUKWILA SEP 2 0 2016 PERMIT CENTER c Bl HOMEWOOD SITES BY HILTON" Seattle/Tukwila, WA Inn Code: SEATK FRC DESIGN WORLDWIDE 311 Elm Street Suite 600 Cincinnati, 011 45202 www.FRCH.com 513 241 3000 Owner 804.727.1757 Apple Hospitality REIT, Inc. 814 East Main Street Richmond, VA 23219 Chris Zeigler Architect 513.241.3000 FRCH/Architecture, Inc., P.C. f: 513.241.5015 311 Elm Street, Suite 600 Cincinnati, OH 45202-2706 Mike Keifling Interior Design 513.241.3000 FRCH Design Worldwide f: 513,241.5015 311 Elm Street, Suite 600 Cincinnati, OH 45202-2706 Raejean Downs ISSUED INFORMATION OWNER REVIEW SET: BRAND REVIEW SET: ISSUED: 19 August 2016 REVISIONS: BLDG. DEPT. COMMENTS 0919.16 FRCH 1 ARCHITECTURE, INC., P.C. 10520. JAMES DEN STATE OF GfSTi STAp N ' FONG TT�ON W"HING... bet i11• PROJECT INFORMATION INTERIOR & EXTERIOR RENOVATION Homewood Suites Tukwila 6955 Fort Dent Way Tukwila, WA 98188-2554 PROJECT NUMBER: 032609.000 _ AfigET INFORMATION 'ED FOR viPLIANC OVED P 5 2016 tukwila DIVISION cessibilit Notes: blic Spaces DRAWN BY: M. Keifling REVIEWED BY: M. Keifling SCALE: As Noted AUTHORIZED FOR: PERMIT id0a0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 K J H G F C B A L /' LIFE SAFETY LEGEND * EXISTING FIRE EXTINGUISHER LOCATION 1 78 NEW FIRE EXTINGUISHER LOCATION ROOM/AREA DESIGN OCCUPANT LOAD OCCUPANT LOAD LEAVING AN AREA EXIT INDICATES OCCUPANTS ARE ENTERING PROTECTED EXIT ENCLOSURE EXIT PATHS: ARROW INDICATES DIRECTION OF EGRESS c EXIT PATHS CONVERGE: NUMBER INDICATES TOTAL OCCUPANTS CONTINUING ALONG EXIT PATH 16 EXIT PATHS DIVERGE: NUMBER INDICATES TOTAL OCCUPANTS CONTINUING ALONG SEPERATE EXIT PATHS 1101 1 -HOUR WALL & PROTECTED OPENING: N63'59'57"E 60.00' EXITING CRITERIA DOOR SIZE CLEAR/DOOR TOTAL CLEAR .2" PER OCCUPANT 36" 33.0" 33.0" 165 OCC. 42" 39.0" 39.0" 195 OCC 48" 45.0" 45.0" 225 OCC. • MONUMENT FOUND O MONUMENT SET • P.K. NAIL FOUND EFJ 0 LIGHT POLE STREET UGHT POLE ELEC. TRANSFORMER AIR CONDITIONER ELEC. MANHOLE ELECTRIC METER 1WER mem WIER WOE UM LIZ= MIN SEWER MANHOLE CC E N OUT A?ANt?'..,..... .;TogM INLET CURB NUJ TELEPHONE BOX TELEPHONE MANHOLE GAS VALVE GAS METER SIGN FLAG POLE c.) , ,q 0607 A1C XArt 101! ■ RP IM -- SITE PLAN 1" =30'-0" 1. DE BOUNDARY AIINUARY OF 2003. ALL 4101211119412 SHOW ISEEN ENE WIRED DAWNS 2 OF Et 111E OSURIE MSS SURVEY UNLIES ODERWSE IVIED. 2. 0111 A ea 1123002 LASTAI. STATION WD AT A 14.03. 11 3. PROCEDURES USED 04 WEI MET WERE PRO VERSE LEASUREUDITS NID MEE OR 12523332.9 STANDARDS ET BY W.A.1~ 332-139-090 MID !A! SY ALTA/ �a, ��,WM LAND OASS OF BEARDS IS BARD UP RECERENCE MEWn 2. 5. AT 11E WE OF MS SURVEY 1149IE WAS NO OBSERVABLE MERE OF FAWN NOYES BUMS EDISTRUCW121 OR BUMS ADDITIONS MIDI MDT 0 AT THE IRE OF MS SURIET TINE,, ;• NO WINCES 54 SWEET THE Y EITHER OR AWARE ARON NE01.1240 3121201211124 Et OBSERVABLE ODE= CR IECEIIT SWEET OR 112112AUC CONSTIWORCIN 7. AT 11E 12E OF ICS SURVEY 11E4E WAS 140 ODERVABLE BEDICE 07 10WE USE AS MEM OR BUNIAL memo at exwar PRO. 8. PROPERTY INFER U AL C0C 1&TIESSA'S 22228.2•E 4 11E£ DEIDESNAINX4 OF '1111EVER WAS NOT Oi 11E =WE CIF WES CE DOCIMENT MEM 1) LATS 2 Sc 3 O 1145 OW OF =ROA SIM RECORDED U1001 RECONDS0 MASER 4 8. 1SAM SHORT I AT NU BEM A UT 70-7-R8. OF PARCEL UNDER3CORDED OF (my OF 0370, 51 SECTION 24. TO0ISICP 23 NOWIN, RANGE 4 EAST. LEMAN, Di KM COUNTY. WAS4D4010N. 100E1101 WITH NI EASENENT 1E D ON aOr r UK SHORT PLAT AS 1 -SS. SITUATE 8I THE COUNTY OF K010, STATE OF WASOIGTON. ALERT: SITE PLAN HAS BEEN ADAPTED FROM EXISTING DRAWINGS PROVIDED BY OWNER. FIELF VERIFY ALL DIMENSIONS PRIOR TO COMMENCEMENT OF ANY WORK. ORGINAL SURVEY PERFORMED BBY WILSON SURVEY/ENGINEERING, JANUARY 10, 2008. --REFER TO WRITTEN DIMENSIONS AND DO NOT SCALE FROM THIS PLAN. REQUIRED WIDTH OF EGRESS: 213 PERSONS DOORWAYS CORRIDORS 42.6" 42.6" ACTUAL WIDTH PROVIDED: DOORWAYS CORRIDORS 46" 53" EDT RP. 1 AUII207210418 L it PAI. ICT 1 • v EGRESS: OCCUPANT LOAD IS MINIMALLY CHANGED BY THE RENOVATION. ALL EXISTING ELEMENTS AND CAPACITY ARE EXISTING TO REMAIN. NO MEANS OF EGRESS EXIT ACCESS, EXIT PASSAGEWAYS, EXIT ENCLOSURES OR EXIT ELEMENTS ARE AFFECTED OR MODIFIED BY THE RENOVATION . THE TOTAL GROSS AREA WILL REMAIN THE SAME UPON COMPLETION OF THE PROJECT MAJOR EXITS ARE INDICATED WITH AN arse An; IN EGRESS DIAGRAM TO THE RIGHT. OCCUPANCY: LOBBY A2-15/NET MEETING ROOM A2-15/NET HOME OFFICE A2-15/NET EXIST. PROPOSED 2475sf 2720sf 165 181 246sf Osf 16 0 242sf 242sf 16 16 OFFICE #1 84sf 84sf B-100/GROSS 1 1 OFFICE #2 B-100/GROSS OFFICE #3 B-100/GROSS GUEST LAUNDRY A2-30/NET FITNESS CENTER A2-50/NET 163sf 123sf 1 1 316sf 316sf 3 3 105sf 105sf 3 3 262sf 405sf 5 8 207 213 EGRESS PLAN NOT TO SCALE PANEL 2 RA 03 -2 -EA "-ASPHALT- R OFFICE #1 (2) 36" DOORS CAPACITY: 270 @.2"/OCC. 57 OCC. EXITING (2) 36" DOORS CAPACITY: 270 @.2"/OCC. 42 OCC. EXITING di 11, FITNESS CENTER 405 /50 0 ) A2 2475 /15 BIa.NAIi;GE' r 1412 I Eil� • 1167,4 - -(p-28-4J- - - -� OFFICE #2 163 /100 J PRIMARY ENTRANCE (ACCESSIBLE) 0 I 0 HOME OFFICE 6) OFFICE #3 316 /100 13. PAZ. Ida ASPHALT-.- EXTRJDFD CURH (2) 22" DOORS CAPACITY: 230 @.2"/OCC. 116 OCC. EXITING ".-ASPHALT,_ 0 GTE 8 GOMPAEI rt, CIGMPACT DO MRS Wr 5.9112 'ASV WM me caws Wiewisste came-eatien mos tralym woo ®I 1 �..-ASPHA.LT`..._ cOMr ACT 1 2.6 STRIPIN (TYP) 0 PAVOAD f' PA' V0ENt S.P. 188-1-55 ZOOS O+NS HEREON WERE ORDEED SY A MOST AT THE PUBLIC COMER or THE LOCAL 2000 AU11400TY. NO A11C I ESWoDE FOR E OR M DIVE SS OF SAID MO MY INFOR0101. 10 FIRM IS NOT NIERPETADMI TICS SAY. ANY MLR OF SAID WOW= L4 MED 10 mow THE LOOAL NEWT DIEM. COVERED ENTRY._ STRIPING- (TYP) 11 `\\ i'i' ,�I) I GUEST LAUNDRY tikroa39 STATUS: ITEM 4319101110 USE ',Iu"IT. 1 MED DORM Mir MOZ WARM MINI PLIMEVAP TOTAL OWNER' RENO 021101 MENEM 9247 REQUIRED OBSERVED 12140/1191111. UN Wei WEE Mat Isp 3 Olt 1 Pat IN atm NONLASIEL MD 0,1.31 540 DLO 0 115 SOURCE OF INFO ME •fiIL* III , _'.I...1 L MIS SWUM Dm 51. 2107 NEU= MOS. 112) MIZE War IlLitriel IR Mtn GOSSIZZIEN p 1 WOODEN TRASH ENCLOSURE PA BENC TRASH BIN '-•ASPHALT-•-- I9 hTANDARU ----_-_-1-_ am_ ,-1 f 0 BUILC'rh,G •SLTBACI(- ".._E;(TRUDi.0 EURg-M r II "-ASPHALT-z- STRIPIN^ (TYP) REVIEWED FOR CODE COMPLIANCE APPROVED OCT 2 5 2016 GREEN TRASH -113 1r' City of Tukwila BUILDING DIVISION 10 11 12 13 14 HOMEWOOD SUITES BY HILTON. Seattle/Tukwila, WA Inn Code: SEATK FRC H DESIGN WORLDWIDE 311 Elm Street Suite 600 Cincinnati, OH 45202 www.FRCH.com 513 241 3000 Owner 804.727.1757 Apple Hospitality REIT, Inc. 814 East Main Street Richmond, VA 23219 Chris Zeigler Architect 513.241.3000 FRCH/Architecture, Inc., P.C. 1:513.241.5015 311 Elm Street, Suite 600 Cincinnati, OH 45202-2706 Mike Keifling Interior Design 513.241.3000 FRCH Design Worldwide 1: 513.241.5015 311 Elm Street, Suite 600 Cincinnati, OH 45202-2706 Raejean Downs ISSUED INFORMATION OWNER REVIEW SET: BRAND REVIEW SET: 28 APRIL 2016 ISSUED: 19 August 2016 REVISIONS: FRCH 1 ARCHITECTURE, INC., P.C. 10520 REG • JA SDENN gLETON A E OF W S NGTON 8-19-2016 PROJECT INFORMATION INTERIOR & EXTERIOR RENOVATION Homewood Suites Tukwila 6955 Fort Dent Way Tukwila, WA 98188-2554 PROJECT NUMBER: 032609.000 SHEET INFORMATION Site Plan, RECEIVED Egress PIaffITY OF TUKV AUG 2 3 201 PERMIT CENT DRAWN BY: A. Cunningham REVIEWED BY: M.Keifling, R.Downs SCALE: As Noted AUTHORIZED FOR: PERMIT id01202 2 3 4 5 6 7 8 9 10 11 12 13 14 Q ALERT: DRAWING HAS BEEN ADAPTED FROM FIELD MEASUREMENTS BY FRCH. FIELD VERIFY ALL DIMENSIONS PRIOR TO COMMENCEMENT OF ANY WORK. C7,771 INDICATES AREA NOT IN SCOPE v BOARDROOM 11 1 1 l II !...I RTIAL HEIGHT PATIO • PREP KITCHEN LODGE 1 FITNESS CENTER OFFICE FRONT DESK SOFFIT TO REMAIN I MENS' WOMENS GM OFFICE EXECUTIVE CENTER. STORAGE ; I - I Y. 1 i 1 1 , 1 1 i I L' I I I DEMOLITION PLAN 3/16" = 11-0" 1 2 s 3 4 5 6 AIL 7 8 9 REMOVE DECORATIVE TRIM - CROWN AND BASE TO REMAIN TYP. COLUMN AT LODGE --41�- -4-- - 4— ro" KEY NOTES (continued): 10 19 20 21 22 23 24 25 26 REMOVE SCONCES AND J -BOXES AT FIREPLACE DECORATIVE TRIM TO REMAIN AT COLUMN REMOVE MANTLE, HEARTH, AND TILE GUEST LAUNDRY DEMOLITION -REMOVE ALL TILE FLOORING AND BASE -REMOVE VINYL WALLCOVERING -REMOVE CEILING MOUNTED LIGHT FIXTURES - POWER TO REMAIN -REMOVE ARTWORK -REMOVE IRONING BOARD AND CABINET -REMOVE TELEPHONE - SALVAGE FOR REUSE -REMOVE FURNITURE AND MILLWORK PUBLIC RESTROOM DEMOLITION -REMOVE VANITY MIRRORS -REMOVE VANITY COUNTERTOP, MILLWORK, AND FAUCETS -REMOVE PLASTIC WALL MOUNTED SOAP DISPENSER -REMOVE ALL FLOORING TILE AND BASE -REMOVE ALL WALL TILE -REMOVE PLASTIC TOILET PAPER DISPENSERS -REMOVE TOILET PARTITIONS -REMOVE PLASTIC PAPER TOWEL DISPENSER -REMOVE VINYL WALLCOVERING -REMOVE VANITY LIGHTING - RELOCATE J -BOX, REFER TO SHEET id8.56 FOR NEW LOCATION -REMOVE ARTWORK -GRAB BARS TO BE SALVAGED CORRIDOR DEMOLITION -REMOVE HOUSE PHONE IN NICHE -REMOVE WOOD SHELF -REMOVE VINYL WALLCOVERING -REMOVE ALL TILE FLOORING - WOOD BASE TO REMAIN -REMOVE CORNER GUARDS -REMOVE ARTWORK -REMOVE SCONCES - J -BOXES TO REMAIN -REMOVE KICKPLATES ON DOORS STAIRS AND LEVEL 02 CORRIDOR -REMOVE ALL CARPET, CARPET PAD - WOOD BASE TO REMAIN -REMOVE VINYL WALLCOVERING -RELOCATE EMPLOYEE LOCKERS ON SECOND FLOOR TO NEW BREAKROOM ON FIRST FLOOR OFFICES (LEVEL 02) -REMOVE ALL CARPET, CARPET PAD & WOOD BASE -REMOVE VINYL WALLCOVERING -REMOVE ARTWORK -SALVAGE ALL COMPUTER EQUIPMENT AND FURNITURE FOR REUSE REMOVE EXISTING SECTION OF INTERIOR WALL AS INDICATED TO THE EXTENTS THAT WILL ACCOMMODATE PROPOSED LAYOUT (PATCH AND REPAIR ADJACENT WALL, FLOOR, AND CEILING TO 'LIKE NEW' CONDITION) REMOVE EXISTING SWING DOOR AND PORTION OF WALL TO ACCOMMODATE NEW DOOR AND WALL LAYOUT - SALVAGE DOOR FRAME FOR REUSE - REFER TO 12A / id4.22 FOR NEW WALL CONSTRUCTION REMOVE ENTIRE SECTION OF DOOR, FRAME AND ASSOCIATED TRIM (SALVAGE FOR POTENTIAL RELOCATION AND REUSE) - PATCH AND REPAIR WALL AS REQUIRED TO RECEIVE NEW FINISHES -4`- --4- -4`- REMOVE ENTIRE SECTION OF WINDOW/DOOR, FRAME AND ASSOCIATED -.- TRIM - PATCH AND REPAIR WALL AS REQUIRED TO RECEIVE NEW FINISHES REMOVE SCONCE AND J -BOX, ABANDON CIRCUIT COMPLETELY AND TIE BACK TO NEAREST LOGICAL WALL TERMINATION. PATCH AND REPAIR WALL TO RECEIVE NEW FINISHES NOT USED REMOVE EXISTING CEILING FANS - POWER SUPPLY TO REMAIN - REFER TO SHEET id4.12 FOR NEW FIXTURE TYPE REMOVE EXISTING CEILING FANS AND RELOCATE J -BOX FOR NEW FAN LOCATION - REFER TO SHEET id4.11 FOR NEW LOCATION COMPUTER AND ELECTRICAL EQUIPMENT TO BE SALVAGED AND RELOCATED PER NEW LAYOUT - REFER TO SHEET id4.11 PATIO FURNITURE TO BE PROTECTED DURING CONSTRUCTION AND REARRANGED PER NEW LAYOUT - REFER TO SHEET id4.12 REMOVE SOFFIT TO BUTTOM OF SUPPORT BEAM - ALIGN WITH ADJACENT WALL OVER RECEPTION DESK - PATCH AND REPAIR WALLS AS REQUIRED TO RECEIVE NEW FINISHES REMOVE EXISTING SECTION OF EXTERIOR WALL AS INDICATED TO THE EXTENTS THAT WILL ACCOMMODATE PROPOSED LAYOUT (PATCH AND REPAIR ADJACENT WALL, FLOOR, AND CEILING TO 'LIKE NEW CONDITION - POSSIBLY A BEARING WALL, VERIFY IN FIELD PRIOR TO CONSTRUCTION REMOVE SECTION OF EXISTING SLAB TO ACCOMODATE NEW FLOOR SLAB AND TURN DOWN FOOTING REMOVE SCONCES AND J -BOXES AT FIREPLACE DECORATIVE TRIM TO REMAIN REMOVE MANTLE, HEARTH, AND TILE LOBBY -4-- -4- -4— GENERAL NOTES: a. b. c. d. e. f. g. FIELD VERIFY ALL DIMENSIONS PRIOR TO ANY AND ALL WORK - REPORT ANY DISCREPANCIES TO THE DESIGNER AND OWNER. ALL FLOORING REMOVAL SHALL INCLUDE THE REMOVAL OF ALL SUBSTRATE AND PREPARATION OF EXISTING SLAB TO RECEIVE NEW FLOORING MATERIALS, INCLUDING NECESSARY SCRAPING, CLEANING, SCARIFYING, LEVELING, FILLING, PATCHING AND REPAIRING, ETC. VERIFY LOCATION OF ALL ELECTRICAL DEVICES LOCATIONS - COORDINATE WITH PROPOSED PLANS TO ASSURE ALL ITEMS ARE ADEQUATELY REMOVED/RECONFIGURED AT AREAS WHERE FLOORING MATERIAL IS TO BE REMOVED, REMOVE ALSO ALL BASE TRIM ASSOCIATED WITH FLOORING, UNLESS NOTED OTHERWISE COORDINATE DISPOSAL, SALVAGE, AND STORAGE WITH OWNER/HOTEL MANAGEMENT REMOVAL OF ALL EXISTING FURNITURE TO BE REMOVED REMOVE INTERIOR SIGNAGE THROUGHOUT PUBLIC AREAS AND CORRIDORS REPLACE ALL CORRIDOR DOOR KICKPLATES WITH BRUSHED CHROME TO MATCH NEW DOOR HARDWARE O KEYNOTES: FRONT PORCH -REMOVE SLL CERAMIC FLOOR TILES AT FRONT PORCH -REMOVE FURNITURE VESTIBULE -REMOVE WALLCOVERING -REMOVE MIRROR AND CONSOLE TABLE -REMOVE FLOOR TILE - WOOD BASE TO REMAIN -CROWN MOULDING TO REMAIN LOBBY / LODGE DEMOLITION -REMOVE ALL TILE FLOORING - WOOD BASE TO REMAIN -REMOVE ALL CARPET, CARPET PAD - WOOD BASE TO REMAIN -REMOVE VINYL WALLCOVERING -REMOVE ALL FURNITURE -REMOVE ARTWORK -REMOVE ALL DRAPERY AND DRAPERY HARDWARE -REMOVE ALL WALL SCONCES THROUGHOUT -J -BOXES TO REMAIN -REMOVE ALL CEILING PENDANTS - J -BOX TO REMAIN IN LOBBY -REMOVE FIREPLACE HEARTH AND MANTLE -REMOVE PANELING ON COLUMNS - CROWN AND BASE TO REMAIN -REMOVE MILLWORK ON EITHER SIDE OF FIREPLACE -REMOVE FRONT DESK MILLWORK AND COUNTERTOP - PATCH AND REPAIR WALLS AS NECESSARY TO 'LIKE NEW' CONDITION TO RECEIVE NEW FINISHES -REMOVE TV - SALVAGE FOR REUSE -REMOVE PANELING FROM COLUMNS EXCEPT 4 COLUMNS AROUND FIREPLACE BOARDROOM DEMOLITION -REMOVE ALL CARPET, CARPET PAD - WOOD BASE TO REMAIN -REMOVE VINYL WALLCOVERING -REMOVE DRAPERY AND DRAPERY HARDWARE -REMOVE CORNER SHELF -REMOVE ALL FURNITURE -REMOVE ARTWORK AND MIRROR -REMOVE MILLWORK AND COUNTERTOP -REMOVE CEILING MOUNTED FIXTURES - PATCH AND REPAIR CEILING TO 'LIKE NEW CONDITION -CONVERT RECESSED CAN - IN CENTER OF ROOM - J -BOX TO RECEIVE NEW FIXTURE -RECESSED CANS TO REMAIN -WOOD BLINDS ON FRENCH DOORS - TO REMAIN OFFICES & EMPLOYEE BREAKROOM DEMOLITION -REMOVE ALL CARPET, CARPET PAD & WOOD BASE -REMOVE WINDOW TREATMENTS AND HARDWARE -REMOVE VINYL WALLCOVERING -REMOVE ARTWORK -SALVAGE ALL COMPUTER EQUIPMENT AND FURNITURE FOR REUS -REMOVE ALL CABINETRY, COUNTERTOPS AND REFRIGERATORS IN STORAGE ROOM - SALVAGE FRIGIDARE FOR REUSE IN KITCHEN PRE -REMOVE FLUSH MOUNTED CEILING FIXTURES - SALVAGE FOR REUSE -CEILING FIXTURE TO REMAIN (IN INDEPENDENT OFFICE) REFER TO SHEET id/4.14 - CROWN TO REMAIN IN GM OFFICE EXECUTIVE CENTER (HOME OFFICE) DEMOLITION -REMOVE ALL CARPET & CARPET PAD - WOOD BASE TO REMAIN -REMOVE VINYL WALLCOVERING -REMOVE ALL FURNITURE, MILLWORK, & COUNTERTOPS -REMOVE TASK CHAIRS -REMOVE ARTWORK -REMOVE CEILING MOUNTED LIGHTS - REFER TO RCP SHEET 14G/id4.22 FOR LOCATION OF NEW RECESSED CANS -REMOVE ALL DRAPERY AND DRAPERY HARDWARE INCLUDING WOOD BLINDS -REMOVE SWITCHES, OUTLETS, AND COVERPLATES - WIRING TO REMAIN -SALVAGE EQUIPMENT FOR REUSE SUITE SHOP DEMOLITION -REMOVE ALL TILE FLOORING AND BASE -REMOVE MILLWORK -REMOVE VINYL WALLCOVERING -REMOVE EQUIPMENT -REMOVE TRACK LIGHTING PANTRY DEMOLITION -REMOVE ALL TILE FLOORING AND BASE -REMOVE VINYL WALLCOVERING -REMOVE ARTWORK -REMOVE WALL AND BASE CABINETS AND COUNTERTOPS -RELOCATE ICE MACHINE TO NEW KITCHEN STORAGE -REMOVE SWINGING DOOR TO PREP KITCHEN -REMOVE ALL EQUIPMENT - SALVAGE KEGERATOR AND MICROWAVE FOR REUSE -REMOVE SWITCHES, OUTLETS, AND COVERPLATES - WIRING TO REMAIN FITNESS CENTER DEMOLITION -REMOVE CEILING MOUNTED LIGHT FIXTURES - POWER TO REMAIN -REMOVE VINYL BASE - FLOOR TILES TO REMAIN -SALVAGE WOOD BLINDS FOR REUSE KEY PLAN: LODGE LOBBY/LODGE D 0.38 10 11 LEVEL 01 City of Tukwila BUILDING DIVISION HOMEWOOD j}Y SIT BY HILTON" Seattle/Tukwila, WA Inn Code: SEATK FRC DESIGN WORLDWIDE 311 Elm Street Suite 600 Cincinnati, OH 45202 www.FRCH.com 513 241 3000 Owner 804.727.1757 Apple Hospitality REIT, Inc. 814 East Main Street Richmond, VA 23219 Chris Zeigler Architect 513.241.3000 FRCH Design Worldwide 1: 513.241.5015 311 Elm Street, Suite 600 Cincinnati, OH 45202-2706 Mike Keifling Interior Design 513.241.3000 FRCH Design Worldwide f: 513.241.5015 311 Elm Street, Suite 600 Cincinnati, OH 45202-2706 Raejean Downs ISSUED INFORMATION OWNER REVIEW SET: BRAND REVIEW SET: 17 June 2016 ISSUED: 19 August 2016 REVISIONS: FRCH 1 ARCHITECTURE, INC., P.C. 10520 REG JA S DENN A EOFW 8-19-2016 • I LETON S NGTON PROJECT INFORMATION INTERIOR & EXTERIOR RENOVATION Homewood Suites Tukwila 6955 Fort Dent Way Tukwila, WA 98188-2554 PROJECT NUMBER: 032609.000 SHEET INFORMATION Demolition Plan: Lobby / Lodc-CEIVED Level 01CIT 1 OF TUKWIL AUG 2 3 2016 PERMIT CENTEF DRAWN BY: A. Cunningham REVIEWED BY: M.Keifling, R.Downs SCALE: As Noted AUTHORIZED FOR: PERMIT K J H G F E D C B A L 1 2 3 4 5 6 7 8 9 10 11 12 13 14 Q ALERT: DRAWING HAS BEEN ADAPTED FROM FIELD MEASUREMENTS BY FRCH. FIELD VERIFY ALL DIMENSIONS PRIOR TO COMMENCEMENT OF ANY WORK. :273INDICATES AREA NOT IN SCOPE r P DEMOLITION PLAN 3/16" = 1'-0" v v v OFFICE // / /// ,// /N�/( 1 2 3 4 A. v KEY NOTES (continued): 1a 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 GUEST LAUNDRY DEMOLITION -REMOVE ALL TILE FLOORING AND BASE -REMOVE VINYL WALLCOVERING -REMOVE CEILING MOUNTED LIGHT FIXTURES - POWER TO REMAIN -REMOVE ARTWORK -REMOVE IRONING BOARD AND CABINET -REMOVE TELEPHONE - SALVAGE FOR REUSE -REMOVE FURNITURE AND MILLWORK PUBLIC RESTROOM DEMOLITION -REMOVE VANITY MIRRORS -REMOVE VANITY COUNTERTOP, MILLWORK, AND FAUCETS -REMOVE PLASTIC WALL MOUNTED SOAP DISPENSER -REMOVE ALL FLOORING TILE AND BASE -REMOVE ALL WALL TILE -REMOVE PLASTIC TOILET PAPER DISPENSERS -REMOVE TOILET PARTITIONS -REMOVE PLASTIC PAPER TOWEL DISPENSER -REMOVE VINYL WALLCOVERING -REMOVE VANITY LIGHTING - RELOCATE J -BOX, REFER TO SHEET id8.56 FOR NEW LOCATION -REMOVE ARTWORK -GRAB BARS TO BE SALVAGED CORRIDOR DEMOLITION -REMOVE HOUSE PHONE IN NICHE -REMOVE WOOD SHELF -REMOVE VINYL WALLCOVERING -REMOVE ALL TILE FLOORING - WOOD BASE TO REMAIN -REMOVE CORNER GUARDS -REMOVE ARTWORK -REMOVE SCONCES - J -BOXES TO REMAIN -REMOVE KICKPLATES ON DOORS STAIRS AND LEVEL 02 CORRIDOR -REMOVE ALL CARPET, CARPET PAD - WOOD BASE TO REMAIN -REMOVE VINYL WALLCOVERING -RELOCATE EMPLOYEE LOCKERS ON SECOND FLOOR TO NEW BREAKROOM ON FIRST FLOOR OFFICES (LEVEL 02) -REMOVE ALL CARPET, CARPET PAD & WOOD BASE -REMOVE VINYL WALLCOVERING -REMOVE ARTWORK -SALVAGE ALL COMPUTER EQUIPMENT AND FURNITURE FOR REUSE REMOVE EXISTING SECTION OF INTERIOR WALL AS INDICATED TO THE EXTENTS THAT WILL ACCOMMODATE PROPOSED LAYOUT (PATCH AND REPAIR ADJACENT WALL, FLOOR, AND CEILING TO 'LIKE NEW CONDITION) REMOVE EXISTING SWING DOOR AND PORTION OF WALL TO ACCOMMODATE NEW DOOR AND WALL LAYOUT - SALVAGE DOOR FRAME FOR REUSE - REFER TO 12A / id4.22 FOR NEW WALL CONSTRUCTION REMOVE ENTIRE SECTION OF DOOR, FRAME AND ASSOCIATED TRIM (SALVAGE FOR POTENTIAL RELOCATION AND REUSE) - PATCH AND REPAIR WALL AS REQUIRED TO RECEIVE NEW FINISHES REMOVE ENTIRE SECTION OF WINDOW/DOOR, FRAME AND ASSOCIATED —4— TRIM - PATCH AND REPAIR WALL AS REQUIRED TO RECEIVE NEW FINISHES REMOVE SCONCE AND J -BOX, ABANDON CIRCUIT COMPLETELY AND TIE BACK TO NEAREST LOGICAL WALL TERMINATION. PATCH AND REPAIR WALL TO RECEIVE NEW FINISHES NOT USED REMOVE EXISTING CEILING FANS - POWER SUPPLY TO REMAIN - REFER TO SHEET id4.12 FOR NEW FIXTURE TYPE REMOVE EXISTING CEILING FANS AND RELOCATE J -BOX FOR NEW FAN LOCATION - REFER TO SHEET id4.11 FOR NEW LOCATION COMPUTER AND ELECTRICAL EQUIPMENT TO BE SALVAGED AND RELOCATED PER NEW LAYOUT - REFER TO SHEET id4.11 PATIO FURNITURE TO BE PROTECTED DURING CONSTRUCTION AND REARRANGED PER NEW LAYOUT - REFER TO SHEET id4.12 REMOVE. SOFFIT TO BUTTOM OF SUPPORT BEAM - ALIGN WITH ADJACENT WALL OVER RECEPTION DESK - PATCH AND REPAIR WALLS AS REQUIRED TO RECEIVE NEW FINISHES REMOVE EXISTING SECTION OF EXTERIOR WALL AS INDICATED TO THE EXTENTS THAT WILL ACCOMMODATE PROPOSED LAYOUT (PATCH AND REPAIR ADJACENT WALL, FLOOR, AND CEILING TO 'LIKE NEW' CONDITION - POSSIBLY A BEARING WALL, VERIFY IN FIELD PRIOR TO CONSTRUCTION REMOVE SECTION OF EXISTING SLAB TO ACCOMODATE NEW FLOOR SLAB AND TURN DOWN FOOTING bt O130 LODGE/OFFICES LEVEL 02 -1`- -4— v GENERAL NOTES: a. b. c. d. e f. 9. FIELD VERIFY ALL DIMENSIONS PRIOR TO ANY AND ALL WORK - REPORT ANY DISCREPANCIES TO THE DESIGNER AND OWNER. ALL FLOORING REMOVAL SHALL INCLUDE THE REMOVAL OF ALL SUBSTRATE AND PREPARATION OF EXISTING SLAB TO RECEIVE NEW FLOORING MATERIALS, INCLUDING NECESSARY SCRAPING, CLEANING, SCARIFYING, LEVELING, FILLING, PATCHING AND REPAIRING, ETC. VERIFY LOCATION OF ALL ELECTRICAL DEVICES LOCATIONS - COORDINATE WITH PROPOSED PLANS TO ASSURE ALL ITEMS ARE ADEQUATELY REMOVED/RECONFIGURED AT AREAS WHERE FLOORING MATERIAL IS TO BE REMOVED, REMOVE ALSO ALL BASE TRIM ASSOCIATED WITH FLOORING, UNLESS NOTED OTHERWISE COORDINATE DISPOSAL, SALVAGE, AND STORAGE WITH OWNER/HOTEL MANAGEMENT REMOVAL OF ALL EXISTING FURNITURE TO BE REMOVED REMOVE INTERIOR SIGNAGE THROUGHOUT PUBLIC AREAS AND CORRIDORS REPLACE ALL CORRIDOR DOOR KICKPLATES WITH BRUSHED CHROME TO MATCH NEW DOOR HARDWARE O KEYNOTES: FRONT PORCH -REMOVE SLL CERAMIC FLOOR TILES AT FRONT PORCH -REMOVE FURNITURE VESTIBULE -REMOVE WALLCOVERING -REMOVE MIRROR AND CONSOLE TABLE -REMOVE FLOOR TILE - WOOD BASE TO REMAIN -CROWN MOULDING TO REMAIN LOBBY / LODGE DEMOLITION -REMOVE ALL TILE FLOORING - WOOD BASE TO REMAIN -REMOVE ALL CARPET, CARPET PAD - WOOD BASE TO REMAIN -REMOVE VINYL WALLCOVERING -REMOVE ALL FURNITURE -REMOVE ARTWORK -REMOVE ALL DRAPERY AND DRAPERY HARDWARE -REMOVE ALL WALL SCONCES THROUGHOUT -J -BOXES TO REMAIN -REMOVE ALL CEILING PENDANTS - J -BOX TO REMAIN IN LOBBY -REMOVE FIREPLACE HEARTH AND MANTLE -REMOVE PANELING ON COLUMNS - CROWN AND BASE TO REMAIN -REMOVE MILLWORK ON ETHER SIDE OF FIREPLACE -REMOVE FRONT DESK MILLWORK AND COUNTERTOP - PATCH AND REPAIR WALLS AS NECESSARY TO 'LIKE NEW' CONDITION TO RECEIVE NEW FINISHES -REMOVE TV - SALVAGE FOR REUSE -REMOVE PANELING FROM COLUMNS EXCEPT 4 COLUMNS AROUND FIREPLACE BOARDROOM DEMOLITION -REMOVE ALL CARPET, CARPET PAD - WOOD BASE TO REMAIN -REMOVE VINYL WALLCOVERING -REMOVE DRAPERY AND DRAPERY HARDWARE -REMOVE CORNER SHELF -REMOVE ALL FURNITURE -REMOVE ARTWORK AND MIRROR -REMOVE MILLWORK AND COUNTERTOP -REMOVE CEILING MOUNTED FIXTURES - PATCH AND REPAIR CEILING TO 'LIKE NEW' CONDITION -CONVERT RECESSED CAN - IN CENTER OF ROOM - J -BOX TO RECEIVE NEW FIXTURE -RECESSED CANS TO REMAIN -WOOD BLINDS ON FRENCH DOORS - TO REMAIN OFFICES & EMPLOYEE BREAKROOM DEMOLITION -REMOVE ALL CARPET, CARPET PAD & WOOD BASE -REMOVE WINDOW TREATMENTS AND HARDWARE -REMOVE VINYL WALLCOVERING -REMOVE ARTWORK -SALVAGE ALL COMPUTER EQUIPMENT AND FURNITURE FOR REUSE -REMOVE ALL CABINETRY, COUNTERTOPS AND REFRIGERATORS IN STORAGE ROOM - SALVAGE FRIGIDARE FOR REUSE IN KITCHEN PREP -REMOVE FLUSH MOUNTED CEILING FIXTURES - SALVAGE FOR REUSE -CEILING FIXTURE TO REMAIN (IN INDEPENDENT OFFICE) REFER TO SHEET id/4.14 - CROWN TO REMAIN IN GM OFFICE EXECUTIVE CENTER (HOME OFFICE) DEMOLITION -REMOVE ALL CARPET & CARPET PAD - WOOD BASE TO REMAIN -REMOVE VINYL WALLCOVERING -REMOVE ALL FURNITURE, MILLWORK, & COUNTERTOPS -REMOVE TASK CHAIRS -REMOVE ARTWORK -REMOVE CEILING MOUNTED LIGHTS - REFER TO RCP SHEET 14G/id4.22 FOR LOCATION OF NEW RECESSED CANS -REMOVE ALL DRAPERY AND DRAPERY HARDWARE INCLUDING WOOD BLINDS -REMOVE SWITCHES, OUTLETS, AND COVERPLATES - WIRING TO REMAIN -SALVAGE EQUIPMENT FOR REUSE SUITE SHOP DEMOLITION -REMOVE ALL TILE FLOORING AND BASE -REMOVE MILLWORK -REMOVE VINYL WALLCOVERING -REMOVE EQUIPMENT -REMOVE TRACK LIGHTING PANTRY DEMOLITION -REMOVE ALL TILE FLOORING AND BASE -REMOVE VINYL WALLCOVERING -REMOVE ARTWORK -REMOVE WALL AND BASE CABINETS AND COUNTERTOPS -RELOCATE ICE MACHINE TO NEW KITCHEN STORAGE -REMOVE SWINGING DOOR TO PREP KITCHEN -REMOVE ALL EQUIPMENT - SALVAGE KEGERATOR AND MICROWAVE FOR REUSE -REMOVE SWITCHES, OUTLETS, AND COVERPLATES - WIRING TO REMAIN FITNESS CENTER DEMOLITION -REMOVE CEILING MOUNTED LIGHT FIXTURES - POWER TO REMAIN -REMOVE VINYL BASE - FLOOR TILES TO REMAIN -SALVAGE WOOD BLINDS FOR REUSE KEY PLAN: A. 5 6 7 8 9 10 11 12 13 ° 14 :D F PLIA ED OCT 2 5 '016 1 HOMEWOOD SUITES BY HILTON" Seattle/Tukwila, WA Inn Code: SEATK FRCHODESIGN WORLDWIDE 311 Elm Street Suite 600 Cincinnati, OH 45202 www.FRCH.com 513 241 3000 Owner 804.727.1757 Apple Hospitality REIT, Inc. 814 East Main Street Richmond, VA 23219 Chris Zeigler Architect 513.241.3000 FRCH Design Worldwide 1: 513.241.5015 311 Elm Street, Suite 600 Cincinnati, OH 45202-2706 Mike Keifling Interior Design 513.2413000 FRCH Design Worldwide f: 513.241.5015 311 Elm Street, Suite 600 Cincinnati, OH 45202-2706 Raejean Downs ISSUED INFORMATION OWNER REVIEW SET: BRAND REVIEW SET: 17 June 2016 ISSUED: 19 August 2016 REVISIONS: FRCH 1 ARCHITECTURE, INC., P.C. PROJECT INFORMATION, INTERIOR & EXTERIOR RENOVATION Homewood Suites Tukwila 6955 Fort Dent Way Tukwila, WA 98188-2554 PROJECT NUMBER: 032609.000 SHEET INFORMATION Demolition Plan: Lodge/OfficesEcteveIO2 CITY OF TUKWP AUG 2 3 2016 PERMIT CENTE DRAWN BY: A. Cunningham REVIEWED BY: M.Keifling, R.Downs SCALE: As Noted AUTHORIZED FOR: PERMIT id1.02 City of Tukwila BUILDING DIVISION K J H G F E D C B A L 4 5 6 7 8 9 10 11 12 13 14 WALK kis tic 0 KEYNOTES: EXTENDED DINING 1d8.01 NEW CONCRETE FOOTING AND 4" THICK CONCRETE SLAB AT NEW ' OUTDOOR "KITCHEN PATIO 16 17 18 FRAMING DIRECTION ASSUMED; FIELD VERIFY EXISTING FRAMING PRIOR TO COMMENCEMENT OF DEMOLITION. IF OTHER THAN INDICATED ON DRAWINGS, CONTACT ARCHOITECT FOR DIRECTION TO PROCEED CONTRACTOR TO INSTALL ADEQUATE POWER SUPPLIES, EASILY ACCESSIBLE FOR STRING LIGHTS - CONTRACTOR TO RUN POWER AND INSTALL ONE(1) DUPLEX AT 18" AFF, ONE(1) DUPLEX AT 96" AFF, AND ONE(1) SWITCH AT 48" AFF AREA OF THICKENED SLAB - REFER TO DETAILS FOR MORE INFORMATION POWER AND SIGNAL LEGEND: PLAN: DUPLEX POWER OUTLET DATA OUTLET VOICE OUTLET 0— :n DECORATIVE WALL SCONCE Ei -- REFER TO FF&E PACKAGE WALL JUNCTION BOX QUAD POWER OUTLET FLOOR DUPLEX CEILING JUNCTION BOX LODGE NEW WALL TYPES: WALK (1) LAYER 5/8" TYPE 'X' GYPSUM BOARD ON EA. SIDE OF 2x4 WOOD STUDS AT 16" o.c. LOCATION: BOH AND SUITE SHOP (1) LAYER 5/8" TYPE 'X' GYPSUM BOARD ON EA. SIDE OF 2x6 WOOD STUDS AT 16" o.c. 6. LOCATION: BOH AND SUITE SHOP 1d8.01 WALL MODIFIER: "x" DESIGNATION INDICATES REQUIRED WALL FIRE RATING INFLIT 1d8.04 1 ST 01 (WC01 1 1d8.04 FITNESS CENTER WALK L i._.. EMPLOYEE -T ;l f iBOOMREAKR.I.. EMI 02 VB 02 Ii— L - { PTI 13 1'7-- — id8.01 12A id8.01 id8.56 WALL FINISH LEGEND: PAINT FINISH WNW. 11.111. 011111M• WALL COVERING TILE STONE CLADDING TRANSITION/STOP POINT ALERT: DRAWING HAS BEEN ADAPTED FROM FIELD MEASUREMENTS BY FRCH. FIELD VERIFY ALL DIMENSIONS PRIOR TO COMMENCEMENT OF ANY WORK, INDICATES AREA NOT IN SCOPE GM OFFICE 1WCI071 HOME OFFICE M® -J PT 1 07 1 JPT1031 SALES OFFICE 11 CONSTRUCTION & FINISH PLAN 3/16" = bt 0)3 9 TWO STORY LODGE & PANTRY LOBBY/LODGE LEVEL 01 —a- -®- v a. b. c. d. e. 9. h. k. GENERAL NOTES: ALL PUBLIC SPACE AREAS TO RECEIVE CARPET SHALL ALSO RECEIVE CARPET PAD - CONTRACTOR SHALL VERIFY ALL QUANTITIES REQUIRED CPP 01 , BOH CPP 02 PROVIDE SHOE MOLDING TO WOOD BASEBOARD AND WOOD CAP TO TILE BASEBOARDS, TO RECEIVE PAINT - REFER TO DETAIL 5A/id8.01 PT 03 ALL NEW WALL COVERING SHALL BE INSTALLED OVER CLEAN, EVEN "PREPARED" WALL SURFACE - CONTRACTOR SHALL VERIFY ALL QUANTITIES REQUIRED ALL SURFACES RECEIVING PAINT MUST BE PATCHED, REPAIRED AND PREPARED TO 'LIKE -NEW' CONDITION IN ORDER TO RECEIVE NEW FINISH ALL PORCELAIN FLOOR TILE SHALL BE INSTALLED OVER EXISTING CONCRETE SLAB USING MEDIUM SET METHOD WITH A LATEX MODIFIED SETTING BED ALL OUTSIDE WALL CORNERS TO RECEIVE CORNER GUARDS AT LOBBY/ LODGE CD 03 ALL DOORS AND FRAMES - IN PUBLIC SPACES - TO RECEIVE PAINT PT 03 , BOH PT 18 ALL ARCHITECTURAL TRIM, WOOD BASE, CROWN MOLDING, ETC. TO RECEIVE PAINT PT 03 BRASS TRIM AT FIREPLACE TO RECEIVE NEW HIGH TEMPERATURE APPROPRIATE SATIN BLACK PAINT - PREPARE AND PRIME AS NECESSARY TO RECEIVE NEW PAINT REPLACE ALL CORRIDOR DOOR KICKPLATES WITH BRUSHED CHROME TO MATCH NEW DOOR HARDWARE METAL GRILLES, PANELS, ETC. LOCATED ON WALLS TO RECEIVE PAINT TO MATCH ADJACENT WALL COLOR - IN SEMI -GLOSS FINISH - LODGE/LOBBY SECOND FLOOR OF LODGE PT 1 19 CORRIDORS PT 103 PT 1 06 U EYNOTES: O O 0 O O 0 11 12 13 14 15 COORDINATE FOR POWER, DATA, AND VOICE OUTLETS TO AT BUSINESS CENTER EQUIPMENT- PROVIDE CONDUIT AND PULL CORDS - REFER TO 8E/id8.01 CONCEAL ALL ELECTRICAL CONNECTIONS BEHIND THE CONNECTED EQUIPMENT - CONCEAL THE WALL MOUNTED PHONE LINE INSTALL NEW FLOOR OUTLET TO POWER FURNITURE / MILLWORK ABOVE - COORDINATE WITH INTERIOR FURNITURE DRAWINGS AND / OR MILLWORK DRAWINGS FOR PROPER LOCATION OF OUTLET RELATIVE TO POWER REQUIREMENTS GC TO RUN WIRING AND INSTALL NEW J -BOX TO RECEIVE WALL SCONCE - LOCATE IN CENTER OF SURFACE, 66" A.F.F. - REFER TO SHEET id4.12 FOR FIXTURE TYPE INSTALL NEW 2 X 4 WITH 5/8" GYPSUM BOARD, ON EITHER SIDE (TOTAL WIDTH 4 3/4"). MATCH EXISTING CONDITIONS, VERIFY IN FIELD. EXPAND FITNESS CENTER: - INSTALL WALLCOVERING ON NEW WALLS - INSTALL FLOORING AND BASE IN EXPANDED AREA - INSTALL 3 ADDITIONAL CEILING LIGHTS - REFER TO SHEET id4.12 FOR FIXTURE TYPE - INSTALL WINDOW TREATMENT - REFER TO SHEET id4.12 FOR FIXTURE TYPE - RELOCATE MIRRORS TO NEW WALL REFER ALSO TO INTERIOR SPECIFICATIONS FOR ADDITIONAL FF&E INFORMATION INSTALL POWER AND DATA FOR NEW TV AT 6'-6" AFF, ON CENTER RELOCATE DRAIN AND FLOOR SINK FOR NEW DROP-IN COLD BIN - CONNECT TO EXISTING DRAIN LINE FROM ABANDONED ISLAND DRAIN PROVIDE NEW DOUBLE WINDOW TO MATCH EXISTING WINDOWS AT "LODGE" SEATING AREA INSTALL APPROPRIATE POWER, CABLE, DATA, SALVAGED COMPUTER, AND ELECTRONIC EQUIPMENT - VERIFY PREFERRED LOCATIONS WITH PROPERTY INSTALL ELECT AT 18" A.F.F. FOR NEW DROP IN COLD PAN - MUCH ACCOMMODATE 3.9 AMPS / 120 V/ s HP WALL TILE TO MATCH EXISTING PREP KITCHEN - RUN FULL HEIGHT WHERE HEARTH WAS REMOVED PATCH AND REPAIR WALL TO RECEIVE NEW FINISH - ADD BASE TO MATCH EXISTING INSTALL NEW WHITE SWITCHES, OUTLETS AND COVER PLATES IN BUFFET AND HOME OFFICE - EXISTING LOCATIONS TO REMAIN INSTALL QUALITY SUB BASE AND TILE SETTING BED TO AVOID CRACKING OF TILES - ALL SLOPES MUST DRAIN AWAY FROM BUILDING AND MEET CODE REQUIREMENTS KEY PLAN: 1 2 3 4 5 6 7 8 9 10 11 12 HOMEWOOD SUITES BY HILTON" Seattle/Tukwila, WA Inn Code: SEATK FRC DESIGN WORLDWIDE 311 Elm Street Suite 600 Cincinnati, OH 45202 www.FRCH.com 513 241 3000 Owner 804.727.1757 Apple Hospitality REIT, Inc. 814 East Main Street Richmond, VA 23219 Chris Zeigler Architect 513.241.3000 FRCH Design Worldwide f: 513.241.5015 311 Elm Street, Suite 600 Cincinnati, OH 45202-2706 Mike Keifling Interior Design 513.241.3000 FRCH Design Worldwide 1: 513.241.5015 311 Elm Street, Suite 600 Cincinnati, OH 45202-2706 Raejean Downs ISSUED INFORMATION OWNER REVIEW SET: BRAND REVIEW SET: 28 April 2016 ISSUED: 19 August 2016 REVISIONS: ................................................................................................................................... FRCH 1 ARCHITECTURE, INC., P.C. 10520 REG • JA S DENN 10 1`% • LETON A EOFW'S NGTON 8-19-2016 PROJECT INFORMATION INTERIOR & EXTERIOR RENOVATION Homewood Suites Tukwila 6955 Fort Dent Way Tukwila, WA 98188-2554 PROJECT NUMBER: 032609.000 SHEET INFORMATION Construction & Finish p(�il • ECEIVED i,i OF TUKWILi Lobby / Lodge AUG 2 3 2016 PERMIT CENTER DRAWN BY: A, Cunningham REVIEWED BY: M.Keifling, R.Downs SCALE: As Noted AUTHORIZED FOR: PERMIT CE id4:, .11 City of Tukwila BUILDING DIVISION K J H G F E D C B A L ► 4 5 6 7 8 9 10 11 12 13 14 LANDSCAPE BED RT -185C — LANDSCAPE BED LANDSCAPE BED AA -301 WALK AA -301 AA -302 AA -302 ( AA -303 WT -100C EXTENDED DINING WT -100D) SG -106 INT -1000 SG -119 (SG -1 CG -120 (CG -128) LT -115 CG -105 CG -105 SG -106 SG -109 WT -100C LT -104 CG -106 SG -108 CG -106 SG -107 LT -102 id8.57 (CG -108) WALK AA -302 AA -301 SG -300 • Q ALERT: DRAWING HAS BEEN ADAPTED FROM FIELD MEASUREMENTS BY FRCH. FIELD VERIFY ALL DIMENSIONS PRIOR TO COMMENCEMENT OF ANY WORK. 11 ��r777INDICATES AREA NOT IN SCOPE • ■ • 10•102001 • O a 0 • 8 • • 1 /LANDSCAPE BED SG -109 LT -102 LT -106 CG -108 SG -110 SG -110 CG -114 KITCHEN PANTRY WT -100B (IIU RT -185B id8.53 RT -185/) LODGE SG -110 CG -108 CG -114 SG -110 id8.57 CG -118 —( LT -105 ART -184 SG -103 AR -102 CG -103 FITNESS CENTER SG -104 GUEST LAUNDRY ELECTRICAL/ /; OFFICE CG -100 ART -186 LOBBY sT (SG -127 MW -03 LT -102 ART -183 RT -182 RT -1828 STORAGE EMPLOYEE IREAKROOM SG -114 OFFICE WOMENS GM OFFICE SALES OFFICE SG -400 SG -115 LT -107 ART -187 \/ /l, - n. SG -114 ART -104, CG -300 id8.56 SG -301 AA -301 AA -302 SG -304 CG -300 SG -306 FRONT PORCH FURNITURE PLAN 3/16" = 1'-0" Ak 3 4 5 A. A. UTDOOR GRILL WALK Dtb-oz38 LOBBY/LODGE 6 7 8 9 10 11 12 --4 —+- -.- -4— GENERAL FURNITURE PLAN NOTES: a. b. c. REFER TO INTERIOR SPECIFICATIONS FOR ALL FURNITURE INFORMATION AND SIZING FIELD VERIFY ALL FURNITURE DIMENSIONS AND FURNITURE ORIENTATIONS (MIRRORED, BUILT-IN, ETC.) AND ELECTRICAL REQUIREMENTS WITH EXISTING CONDITIONS FOR KITCHEN PREP AND KITCHEN STORAGE EQUIPMENT POWER - REFER TO id4.22 O KEYNOTES: EXPANDED FITNESS CENTER: - INSTALL WALLCOVERING ON NEW WALLS - REFER TO SHEET id4.11 - INSTALL FLOORING IN EXPANDED AREA - REFER TO SHEET id4.11 - INSTALL 3 ADDITIONAL CEILING LIGHTS -INSTALL WINDOW TREATMENT - REFER TO PRECOR PROVIDED LAYOUT FOR EQUIPMENT LOCATIONS AND SPECIFICATIONS REFER ALSO TO INTERIOR SPECIFICATIONS FOR ADDITIONAL FF&E INFORMATION INSTALL SALVAGED TV IN LODGE INSTALL SALVAGED TELEPHONE IN GUEST LAUNDRY OWNER TO PROVIDE 55" TV - VERIFY CONNECTIVITY IS ADEQUATE WITH NEW FLAT SCREEN TV EXISTING PATIO FURNITURE TO REMAIN RELOCATE DOUBLE OVEN RELOCATE ICE MACHINE, COFFEE AND JUICE BREWING STATION RELOCATE M3 TURBO FREEZER RELOCATE FRIGIDAIRE FREEZER OWNER TO PROVIDE SHELVING OWNER TO PROVIDE NEW EQUIPMENT FOR SUITE SHOP EXISTING WOOD BLINDS TO REMAIN IN FITNESS CENTER PROPERTY TO PROVIDE STRING LIGHTS. IF POWER DOES NOT EXIST, CONTRACTOR TO INSTALL ADEQUATE POWER SUPPLIES, EASILY ACCESSIBLE. CONTRACTOR RUN POWER AND INSTALL ONE(1) DUPLEX AT 18"AFF, ONE DUPLEX AT 96"AFF, AND ONE(1) SWITCH AT 48"AFF. KEY PLAN: IA APPROVED 13 14 OCT 2 5 2016 HOMEWOOD SUITES BY HILTON" Seattle/Tukwila, WA Inn Code: SEATK FRCH) DESIGN WORLDWIDE 311 Elm Street Suite 600 Cincinnati, OH 45202 www.FRCH.com 513 241 3000 Owner Apple Hospitality REIT, Inc. 814 East Main Street Richmond, VA 23219 Chris Zeigler 804.727.1757 Architect 513.241.3000 FRCH Design Worldwide f: 513.241.5015 311 Elm Street, Suite 600 Cincinnati, OH 45202-2706 Mike Keifling Interior Design 513.241.3000 FRCH Design Worldwide f: 513.241.5015 311 Elm Street, Suite 600 Cincinnati, OH 45202-2706 Raejean Downs ISSUED INFORMATION OWNER REVIEW SET: BRAND REVIEW SET: 28 April 2016 ISSUED: 19 August 2016 REVISIONS: FRCH 1 ARCHITECTURE, INC., P.C. PROJECT INFORMATION INTERIOR & EXTERIOR RENOVATION Homewood Suites Tukwila 6955 Fort Dent Way Tukwila, WA 98188-2554 PROJECT NUMBER: 032609.000 SHEET INFORMATION Furniture Plan: Lobby / I wIgpoF TUKWII AUG 2 3 2016 PFRMIT CFNTE DRAWN BY: A, Cunningham REVIEWED BY: M.Keifling, R.Downs SCALE: As Noted AUTHORIZED FOR: PERMIT id4.12 City of Tukwila BUILDING DIVISION K J H G F E D C B A L 1 2 3 4 5 6 7 8 9 10 11 12 13 14 CROWN MOLDING & PANELS CROWN MOLDING CROWN MOLDING & PANELS TWO STORY LODGE L_ CONSTRUCTION, FINISH, & FURNITURE PLAN 3/16" = 1'-0" 1 2 3 1 11 1 11 1 1 1. HALF WALL 1 1 1 1 r 1 LODGE BELOW J WC 01 r.�NsNselm mmm- r ■uur / / 6/ / / / / / / / / /// / / %moi / / C 03 CPP 02 1 PT 03 1 CORRIDOR HALF WALL WC1231.1 WC 23 / / /aro / , / . / / ./ ■ D WV / �/ / //,6 ^i / / /a / / PI C 04 VB 02 CPP 02 O IwCI 15 • / / / / / / / / / r J Dib- 0)3 4 5 6 7 8 9 10 11 -®- -4- -4— -4- a. b. c. d. e. f. g. h. GENERAL NOTES: LOBBY AND LODGE CEILINGS SHALL BE PAINTED AS NECESSARY - REFER ALSO TO INTERIOR SPECIFICATIONS FOR PAINT INFORMATION PT 07 ALL PUBLIC SPACE AREAS TO RECEIVE CARPET SHALL ALSO RECEIVE CARPET PAD - CONTRACTOR SHALL VERIFY ALL QUANTITIES REQUIRED CPP 01 , BOH CPP 02 ALL NEW WALL COVERING SHALL BE INSTALLED OVER CLEAN, EVEN "PREPARED" WALL SURFACE - CONTRACTOR SHALL VERIFY ALL QUANTITIES REQUIRED ALL SURFACES RECEIVING PAINT MUST BE PATCHED, REPAIRED AND PREPARED TO 'LIKE -NEW' CONDITION IN ORDER TO RECEIVE NEW FINISH ALL OUTSIDE WALL CORNERS TO RECEIVE CORNER GUARDS AT LOBBY/ LODGE CD 1 03 ALL DOORS AND FRAMES - FACING PUBLIC SPACES - TO RECEIVE PAINT PT 03 ALL DOORS AND FRAMES - IN BACK OF HOUSE OFFICE - TO RECEIVE PAINT PT 113 ALL ARCHITECTURAL TRIM, WOOD BASE, CROWN MOLDING, ETC. TO RECEIVE PAINT PT 03 ALL SOFFITS TO RECEIVE PAINT PT 08 METAL GRILLES, PANELS, ETC. LOCATED ON WALLS TO RECEIVE PAINT TO MATCH ADJACENT WALL COLOR - IN SEMI -GLOSS FINISH - LODGE/LOBBY SECOND FLOOR OF LODGE pT 19 CORRIDORS PT 03 PT 1 06 O KEYNOTES: 0 O STAIR RAILING AND HALF WALL TRIM TO RECEIVE PAINT PT 1 03 RELOCATE ELECTRICAL TOWERS(2) - FROM FIRST FLOOR BACK OF HOUSE - VERIFY WITH PROPERTY FOR NEW LOCATION WALL FINISH LEGEND: H4 PAINT FINISH WALL COVERING TILE STONE CLADDING TRANSITION/STOP POINT Q ALERT: DRAWING HAS BEEN ADAPTED FROM FIELD MEASUREMENTS BY FRCH. FIELD VERIFY ALL DIMENSIONS PRIOR TO COMMENCEMENT OF ANY WORK. (INDICATES AREA NOT IN SCOPE KEY PLAN: LODGE/OFFICES LEVEL 02 12 tk 13 AIL F PLI •; APPR0_ED HOMEWOOD SUITES BY HILTON'" Seattle/Tukwila, WA Inn Code: SEATK FRCHIDESIGN WORLDWIDE 311 Elm Street Suite 600 Cincinnati, OH 45202 www.FRCH.com 513 241 3000 Owner Apple Hospitality REIT, Inc. 814 East Main Street Richmond, VA 23219 Chris Zeigler 804.727.1757 Architect 513.241.3000 FRCH Design Worldwide f: 513.241.5015 311 Elm Street, Suite 600 Cincinnati, OH 45202-2706 Mike Keifling Interior Design FRCH Design Worldwide 311 Elm Street, Suite 600 Cincinnati, OH 45202-2706 Raejean Downs 513.241.3000 f: 513.241.5015 ISSUED INFORMATION OWNER REVIEW SET: BRAND REVIEW SET: 28 April 2016 ISSUED: 19 August 2016 REVISIONS: FRCH 1 ARCHITECTURE, INC., P.C. PROJECT INFORMATION INTERIOR & EXTERIOR RENOVATION Homewood Suites Tukwila 6955 Fort Dent Way Tukwila, WA 98188-2554 PROJECT NUMBER: 032609.000 SHEET INFORMATION Construction & Finish Plan: Lodge/Offi � h 02J AUG 2 3 2016 PERMIT CENTER DRAWN BY: A, Cunningham REVIEWED BY: M.Keifling, R.Downs SCALE: As Noted AUTHORIZED FOR: PERMIT id4.13 14 OCT 2 5 2016 City of Tukwila BUILDING DIVISION K J H G F E D C B USER: MKEIFLING L s 3 4 v 5 6 7 8 9 v 10 11 12 QALERT: DRAWING HAS BEEN ADAPTED FROM FIELD MEASUREMENTS BY FRCH. FIELD VERIFY ALL DIMENSIONS PRIOR TO COMMENCEMENT OF ANY WORK. EXTENDED DINING PANTRY LODGE KITCHEN PREP PERIMETER OF ISLAND BELOW 0 KITCHEN STORAGE SUITE SHOP FITNESS ENTER a OFFICE FRONT DESK LOBBY GUEST LAUNDRY EMPLOYEE w BREAKROOM GM OFFICE SALES OFFICE VESTIBULE HOME OFFICE WOMENS REFLECTED CEILING PLAN 3/16" = 1'-0" 1 2 3 4 a 5 6 FRONT PORCH s 7 8 • 2-0" 9 10 INDICATES AREA NOT IN SCOPE bib- 0)39 11 LOBBY/LODGE LEVEL 01 12 13 14 GENERAL NOTES: LOBBY, LODGE, FITNESS CENTER, HOME OFFICE, SUITE SHOP AND EXPANDED DINING CEILINGS SHALL BE PAINTED AS NECESSARY - REFER ALSO TO INTERIOR SPECIFICATIONS FOR PAINT INFORMATION PT 07 ALL SURFACES RECEIVING PAINT MUST BE PATCHED, REPAIRED AND PREPARED TO 'LIKE -NEW CONDITION IN ORDER TO RECEIVE NEW FINISH GC TO VERIFY ALL EXISTING CONDITIONS PRIOR TO CONSTRUCTION ELECTRICAL ELECTRICAL CONTRACTOR TO COORDINATE FIXTURE PLACEMENT WITH HVAC LOCATIONS PRIOR TO INSTALLATION — 4- 4- - 4- - 4- -4- - 4- -4- -4— -4— O EYNOTES: INSTALL NEW DECORATIVE LIGHT FIXTURES WITH NEW J -BOX AT CEILING ON DEDICATED CIRCUIT AND SEPARATE SWITCH WITH DIMMING CAPABILITY - REFER TO id4.12 AND INTERIOR SPECIFICATION FOR FIXTURE TYPE - AT BUSINESS CENTER - REFER TO SHEET id4.22 FOR EXACT LOCATION RELOCATE CEILING FAN J -BOX - REFER TO SHEET id4.12 FOR FIXTURE TYPE INSTALL NEW 6" RECESSED CEILING FIXTURES - REFER TO MEP DRAWINGS FOR SPECIFICATION EXISTING FLUSH MOUNTED FLOURESCENT FIXTURE TO REMAIN INSTALL NEW FLUSH MOUNTED FIXTURES IN EXISTING LOCATIONS - INSTALL NEW FLUSH MOUNTED FLOURESCENT FIXTURE - ALIGN WITH EXISTING FIXTURE LOCATIONS - CLT -126 INSTALL SALVAGED FLUSH MOUNTED FLOURESCENT FIXTURE INSTALL CROWN MOLDING TO MATCH EXISTING - RUN PERIMETER OF NEW LAYOUT EXISTING RECESSED CEILING FIXTURES TO REMAIN POWER AND SIGNAL LEGEND: h. PLAN: DUPLEX POWER OUTLET DATA OUTLET VOICE OUTLET DECORATIVE WALL SCONCE -- REFER TO FF&E PACKAGE WALL JUNCTION BOX QUAD POWER OUTLET FLOOR DUPLEX CEILING JUNCTION BOX KEY PLAN: LODGE —®- 13 14 F COIU'IPLI APPRO*E HOMEWOOD SUITES BY HILTON" Seattle/Tukwila, WA Inn Code: SEATK FRCHIDESIGN WORLDWIDE 311 Elm Street Suite 600 Cincinnati, OH 45202 www.FRCH.com 513 241 3000 Owner Apple Hospitality REIT, Inc. 814 East Main Street Richmond, VA 23219 Chris Zeigler 804.727.1757 Architect 513.241.3000 FRCH Design Worldwide f: 513.241.5015 311 Elm Street, Suite 600 Cincinnati, OH 45202-2706 Mike Keifling Interior Design 513.241.3000 FRCH Design Worldwide f: 513.241.5015 311 Elm Street, Suite 600 Cincinnati, OH 45202-2706 Raejean Downs ISSUED INFORMATION OWNER REVIEW SET: BRAND REVIEW SET: 17 June 2016 ISSUED: 19 August 2016 REVISIONS: FRCH 1 ARCHITECTURE, INC., P.C. PROJECT INFORMATION INTERIOR & EXTERIOR RENOVATION Homewood Suites Tukwila 6955 Fort Dent Way Tukwila, WA 98188-2554 PROJECT NUMBER: 032609.000 SHEET INFORMATION Reflected Ceiling Plan: Lobby / Lodge, BOH, Home1Qfft.0,EK-E\)v Fitness Center AUG 2 3 2016 PE MIT CENT' DRAWN BY: A. Cunningham REVIEWED BY: M.Keifling, R.Downs SCALE: As Noted AUTHORIZED FOR: PERMIT OCT 2 5 2016 City of Tukwila BUILDING DIVISION 3 4 5 6 7 8 9 NV 10 11 NV 12 13 14 GENERAL NOTES: a. (1) LAYER 5/8" TYPE 'X' GYPSUM BOARD ON EA, SIDE OF 2x4 WOOD STUDS AT 16" o.c. ALL PUBLIC SPACE AREAS TO RECEIVE CARPET SHALL ALSO RECEIVE CARPET PAD - CONTRACTOR SHALL VERIFY ALL QUANTITIES REQUIRED CPP 01 4}" LOCATION: BOH AND SUITE SHOP WALL MODIFIER: b. "x" DESIGNATION INDICATES REQUIRED WALL FIRE RATING INOH URS' C. d. ALL NEW WALL COVERING SHALL BE INSTALLED OVER CLEAN, EVEN "PREPARED" WALL SURFACE - CONTRACTOR SHALL VERIFY ALL QUANTITIES REQUIRED ALL SURFACES RECEIVING PAINT MUST BE PATCHED, REPAIRED AND PREPARED TO 'LIKE -NEW' CONDITION IN ORDER TO RECEIVE NEW FINISH ALL OUTSIDE WALL CORNERS TO RECEIVE CORNER GUARDS AT MEETING ROOM CD 04 KITCHEN PREP Q ALERT: e. f. DRAWING HAS BEEN ADAPTED FROM FIELD MEASUREMENTS BY FRCH. FIELD VERIFY ALL DIMENSIONS PRIOR TO COMMENCEMENT OF ANY WORK. C: INDICATES AREA NOT IN SCOPE ALL DOORS AND FRAMES - IN MEETING ROOM - TO RECEIVE PAINT PT 03 GC TO REVIEW POWER REQUIREMENTS OF NEW AND REUSED EQUIPMENT PRIOR TO INSTALLATION - COORDINATE WITH PROPERTY FINAL LOCATIONS EYNOTES: 0 O 0 0 0 PANTRY O INSTALL NEW SWINGING DOOR AND HARDWARE TO PREP KITCHEN RELOCATE EXISTING POWER, DATA, AND VOICE TO NEW WALL - CONSULT WITH PROPERTY ON FINAL LOCATIONS NEW BI -PASS CLOSET DOORS AND HARDWARE WITHIN EXISTING OPENING, DOOR: MOHAWK - 6 PANEL DOOR, 1 3/8" THICK, HARDWARE: JOHNSON 138F MILLED FINISH WITH BOTTOM TRACK (FULL LENGTH GUIDES) AND ROOKWOOD FLUSH PULL 95B SATIN NICKEL, FIELD VERIFY -INSTALL NEW LAMINATE COVERED SHELF AND HANGING ROD - DEPTH OF SHELF 15" - STAINLESS STEEL BAR NOT LESS THAN 1" DIAMETER - MOUNT BAR AT 5'6" AFF REUSE SALVAGED DOOR, FRAME AND HARDWARE - IN NEW LOCATION - GC TO CONFIRM EACH DOOR IS 36" W PROVIDE NEW RECESSED CEILING MOUNTED ELECTRIC PROJECTION SCREEN - PROVIDE TRIM KIT TO MATCH EXISTING SUSPENDED CEILING TRACK - DA -LITE COSMOPOLITAN WITH REMOTE AND WALL CONTROL (LOCATED NO MORE THAN 48" TO TOP OF CONTROL A.F.F.) PROVIDE NEW STACK CHAIRS (SG -116) - REFER TO INTERIOR SPECIFICATIONS 0 0 t 0 KITCHEN STORAGE FRONT DESK FRAMING CONVERT FLOURESCENT LIGHTING TO DIMMABLE LED LAMPS- INSTALL A DEDICATED CIRCUIT AND SEPARATE SWITCH WITH DIMMABLE CAPABILITY FOR RECESSED CAN LIGHTING, LIGHT WELLS AND NEW WALL SCONCES INSTALL NEW DOOR VIEWER AT MAIN OFFICE DOOR ENTRY - ROOKWOOD 622UL LISTED DOOR VIEWER - SATIN NICKEL GC TO INSTALL APPROPRIATE POWER FOR RELOCATED FREEZERS RELOCATE 240V ELECTRIC FOR RELOCATED DOUBLE OVEN INSTALL APPROPRIATE POWER AND COLD WATER LINES WITH WATER FILTERS FOR RELOCATED ICE MACHINE AND JUICE/COFFEE MACHINES - GC TO COORDINATE APPROPRIATE REQUIREMENTS WITH EQUIPMENT SPECIFICATIONS INSTALL DRAIN IN EXPANDED KITCHEN STORAGE AREA - CENTER IN ROOM INSTALL POWER FOR NEW REFRIGERATOR AT EMPLOYEE BREAKROOM INSTALL CONVENIENCE OUTLET AT 42" AFF AT EMPLOYEE BREAKROOM INSTALL ELECTRONIC LOCKSET - HARDWARE FINISH TO MATCH THROUGHOUT - SATIN CHROME OR SATIN STAINLESS BUILD OUT EXISTING HALF WALL TO FULL HEIGHT, FIELD VERIFY EXISTING STUD SIZE, NEW GYP. BOARD ON EITHER SIDE TO EXTEND FROM FLOOR TO CEILING. REFER TO FINISH PLAN FOR MOER INFORMATION FRAMING DIRECTION ASSUMED; FIELD VERIFY EXISTING FRAMING PRIOR TO COMMENCEMENT OF DEMOLITION. IF OTHER THAN INDICATED ON DRAWINGS, CONTACT ARCHOITECT FOR DIRECTION TO PROCEED INSTALL ELECTRICAL OUTLET FOR UNDERCABINET MICROWAVE POWER AND SIGNAL LEGEND: PLAN: KEY PLAN: 4— DUPLEX POWER OUTLET DATA OUTLET VOICE OUTLET DECORATIVE WALL SCONCE El -- REFER TO FF&E PACKAGE WALL JUNCTION BOX QUAD POWER OUTLET FLOOR DUPLEX CEILING JUNCTION BOX SALES OFFICE ENLARGED CONSTRUCTION PLAN 1/4" = BOH, SUITE SHOP AND PANTRY LODGE 10 11 12 13 City of Tukwila BUILDING DIVISION HOMEWOOD . SITES BY HILTON" Seattle/Tukwila, WA Inn Code: SEATK FRC DESIGN WORLDWIDE 311 Elm Street Suite 600 Cincinnati, OH 45202 www.FRCH,com 513 241 3000 Owner 804.727.1757 Apple Hospitality REIT, Inc. 814 East Main Street Richmond, VA 23219 Chris Zeigler Architect 513.241.3000 FRCH Design Worldwide f: 513.241.5015 311 Elm Street, Suite 600 Cincinnati, OH 45202-2706 Mike Keifling Interior Design 513.241.3000 FRCH Design Worldwide f: 513.241.5015 311 Elm Street, Suite 600 Cincinnati, OH 45202-2706 Raejean Downs ISSUED INFORMATION OWNER REVIEW SET: BRAND REVIEW SET: 28 April 2016 ISSUED: 19 August 2016 REVISIONS: FRCH 1 ARCHITECTURE, INC., P.C. 10520 REG •_� yN.• ' T JA S DENN ) ia`•LETON A E OF W. S r= NGTON 8-19-2016 PROJECT INFORMATION INTERIOR & EXTERIOR RENOVATION Homewood Suites Tukwila 6955 Fort Dent Way Tukwila, WA 98188-2554 PROJECT NUMBER: 032609.000 SHEET INFORMATION Enlarged Construction F. & I=ini I� ' ! Suite Shop, antry 6RWILA AUG 2 3 2016 PERMIT CENTER DRAWN BY: A. Cunningham REVIEWED BY: M.Keifling, R.Downs SCALE: As Noted AUTHORIZED FOR: PERMIT id41322 © 2016 This drawing, printed or otherwise, is the copyrighted property of FRCH Design Worldwide and FRCH/Architecture, Inc., P.C. The drawing may not be used, reproduced or copied without the permission of FRCH Design Worldwide or FRCH/Architecture, Inc., P.0 2 3 4 5 6 7 8 9 10 11 12 13 14 EXISTING WOOD BASE -TO RECEIVE PAINT PT 1 03 lett SHOE MOLDING - TO RECEIVE PAINT PTI 03 DETAIL Full Scale 1/2" SHOE MOLDING @ LOBBY Ak CONCRETE FLOOR SLAB - EXISTING 4" 3" 7 c_ DETAIL ELECTRICAL PLACEMENT 3/4" = 11-0" HOME OFFICE AIL TILED FLOOR JOHNSONITE PVC THRESHOLD CD -40-B ALIGN ALL ADJACENT SURFACES RESILIENT FLOORING NV' CARPETED FLOOR ANIk FLOOR TRANSITION Full Scale btb- 0)3 8 CONCRETE FLOOR SLAB FLOOR TRANSITION TILE TO RESILIENT FLOORING Full Scale 11. JOHNSONITE CD -47-A WITH TRACK BASE MT -00-A ALIGN ALL ADJACENT SURFACES TILE FLOOR 111111111111111111IIIIIIII111111IIIIfililill il dllll�lll lilll;�marmintimi EXISTING FLOOR SLAB CARPET TO TILE FRONT DESK HWTui_8.01 AL TRANSITION STRIP - CERAMIC TOOL COMPANY - CTC 38MCT FOR 3/16" TILE THICKNESS - CTC 716MCT FOR 7/16" TILE THICKNESS TILE FLOORING - PROVIDE STANDARD GROUT JOINT BETWEEN AL TRANSITION STRIP AND TILE ALIGN ALL ADJACENT SURFACES CARPET TILE �IIINIIIIIwIIIIIIIIIIIIIIIIIIIIIIiIIIIIIIIIIIIIIIIIIIIII�I��� FLOOR TRANSITION Full Scale AIL EXIST. CONCRETE FLOOR CARPET TO TILE R ED 1= CODE COMPLIA APPROVED 2 3 4 5 6 7 8 9 10 11 12 13 14 OCT 2 5 2016 HOMEWOOD .. SLIITES BY HILTO Nu' Seattle/Tukwila, WA Inn Code: SEATK FRC DESIGN WORLDWIDE 311 Elm Street Suite 600 Cincinnati, OH 45202 www.FRCH.com 513 241 3000 Owner 804.727.1757 Apple Hospitality REIT, Inc. 814 East Main Street Richmond, VA 23219 Chris Zeigler Architect 513.241.3000 FRCH Design Worldwide 1: 513.241.5015 311 Elm Street, Suite 600 Cincinnati, OH 45202-2706 Mike Keifling Interior Design , 513.241.3000 FRCH Design Worldwide f: 513.241.5015 311 Elm Street, Suite 600 Cincinnati, OH 45202-2706 Raejean Downs ISSUED INFORMATION OWNER REVIEW SET: BRAND REVIEW SET: 17 June 2016 ISSUED: 19 August 2016 REVISIONS: FRCH 1 ARCHITECTURE, INC., P.C. 10520' REG' •�' T JA S DENN <. £ • LETON A E OF W S 1 NGTON 8-19-2016 PROJECT INFORMATION INTERIOR & EXTERIOR RENOVATION Homewood Suites Tukwila 6955 Fort Dent Way Tukwila, WA 98188-2554 PROJECT NUMBER: 032609.000 SHEET INFORMATION Interior_Details Deta CITY OF TUKWILA AUG 2 3 2016 PERMIT CENTER DRAWN BY: A. Cunningham REVIEWED BY: M. Keifling SCALE: As Noted AUTHORIZED FOR: PERMIT id8001 City of Tukwila BUILDING DIVISION , 0 U U 8 cc is 0 2 .92 D. ro n: ti U is Tal 0 o. t3 L_ fA 0 0 m USER: MKEIFLING K J H G F E D C B 4 5 6 v 7 3/4" STONE COUNTER TOP - EASE ALL EXPOSED EDGES TO MIN 1/8" RADIUS 3/4" MARINE GRADE PLYWOOD SUBSTRATE dr 1 1/2" 3 5/8" 20ga GALVANIZED METAL STUDS AT 1'-4" o.c. ON 20ga GALV. METAL TRACK OVER SILL SEALER PROVIDE GALV. 3/8" ANCHOR SLEEVE INTO CONCRETE SLAB SEAL JOINT AT SLAB .a 2) #4 BARS CONTINUOUS DETAIL 1 1/2" = 1'-0" 1/2" CONCRETE CEMENT BOARD OVER METAL STUDS EACH SIDE ELDORADO STONE EUROPEAN LEDGE - INSTALL PER MANUFACTURER'S SPECIFICATIONS ST 1 01 SEAL JOINT AT SLAB CONCRETE SLAB STAINLESS STEEL FULLY ADHERED TO DENS -GLASS SHEATHING OVER METAL FRAMING ONLY AT SURFACES CALLED OUT ON PLANS 3 5/8" 20ga GALVANIZED METAL STUDS AT 1'-4" o.c. ON 20ga GALV. METAL TRACK OVER SILL SEALER PROVIDE GALV. 3/8" ANCHOR SLEEVE INTO EXISTING CONCRETE SLAB SEAL JOINT AT SLAB ° °• 2) #4 BARS CONTINUOUS DETAIL 1 1/2" = 1'-0" ELDORADO EUROPEAN LEDGE STONE, SET - INSTALL PER MANUFACTURER'S SPECIFICATIONS ST 101 4" LIGHT GRAY 4,000psi REINFOR CONCRETE (W2.9 x W2.9 - 6" x 6" WIRE MESH - WITH TOOLED JOIN AND BROOM FINISH OVER 4" COMPACTED GRAVEL BASE COUF OUTDOOR KITCHEN 1/2" CONCRETE CEMENT BOARD OVER METAL STUDS EACH SIDE SEAL JOINT AT SLAB CONCRETE SLAB 10" 4" LIGHT GRAY 4,000psi REINFORCED CONCRETE (W2.9 x W2.9 - 6" x 6" WIRE MESH - WITH TOOLED JOINTS AND BROOM FINISH OVER 4" COMPACTED GRAVEL BASE COURSE OUTDOOR KITCHEN CV ELEVATION 3/4" = 1'-0" ELDORADO EUROPEAN LEDGE STONE, SET - INSTALL PER MANUFACTURER'S SPECIFICATIONS ST 101 OUTDOOR KITCHEN • CV ELEVATION 3/4" = 1'-0" OUTDOOR KITCHEN AIL 3/4" THICK GRANITE OVER 3/4" MARINE GRADE PLYWOOD SUBSTRATE ST 1 06 CONCRETE SLAB SECTION 3/4" = DETAIL Full Scale TUTIUITTIMITIMUTTLLIWI1J IIil 3/4" THICK GRANITE OVER 3/4" MARINE GRADE PLYWOOD SUBSTRATE ST 1 06 CONCRETE SLAB SECTION 3 5/8" 20ga. METAL STUD FRAMING - BOTTOM TRACK TO BE INSTALLED ON SILL SEALER BED STAINLESS STEEL ) BACK • 3" NEW STACKED STONE VENEER ST 1 01 PROVIDE OVERLAPPING CORNER DETAIL. ALL CORNERS TO BE SQUARE AND PLUMB. SEAL JOINT 22ga STAINLESS STEEL SHEET STUD CAVITY 8 OUTDOOR KITCHEN STAINLESS STEEL BACK • OUTDOOR KITCHEN 3x3x3/8 PAINTED METAL ANGLE W/ STAINLESS APRON 3 5/8" 20ga. METAL STUD FRAMING - BOTTOM TRACK TO BE INSTALLED ON SILL SEALER BED OUTDOOR KITCHEN • • ELEVATION .64 (STAINLBEASCSKSTEELD • 1-9 • cSTAINLBEASCSKSTEELD OUTDOOR KITCHEN ELDORADO EUROPEAN LEDGE STONE, SET - INSTALL PER MANUFACTURER'S SPECIFICATIONS ST 1 01 ELEVATION 3/4" = STAINLESS STEEL) BACK CFOR"weber s-310" GRILL OPENING (34"W x 64 1/2"H DESIGN SIZE -VERIFY) NO SIDE TABLES INSTALLED) STAINLESS STEEL) BACK CFOR"weber s-310" GRILL OPENING DESIGN SIZE -VERIFY) NO SIDE TABLES INSTALLED) PI it OUTDOOR KITCHEN ELDORADO EUROPEAN LEDGE STONE, SET - INSTALL PER MANUFACTURER'S SPECIFICATIONS ST 1 01 9 4 5/8" 10 11 12 13 14 4 5/8" 4 5/8" 1 TYP. • OPENING DESIGNED FOR "weber s-310" GRILL (34"W x 64 1/2"H DESIGN SIZE -VERIFY NO SIDE TABLES INSTALLED) OPENING DESIGNED FOR "weber s-310" GRILL (34"W x 64 1/2"H DESIGN SIZE -VERIFY NO SIDE TABLES INSTALLED) PLAN 3/4" = 3 5/8' 1 1 OUTDOOR KITCHEN BASE DIMENSIONS 14G id8.02 3 5/8" 3 5/8" f f \— 3x3x3/8 PAINTED METAL ANGLE W/ STAINLESS APRON - MIN. 4" BEARING, BOLT TO STUD BELOW, TYP. EACH SIDE id8.02 OPENING DESIGNED FOR "weber s-310" GRILL (34"W x 64 1/2"H DESIGN SIZE -VERIFY NO SIDE TABLES INSTALLED) OPENING DESIGNED FOR "weber s-310" GRILL (34"W x 64 1/2"H DESIGN SIZE -VERIFY NO SIDE TABLES INSTALLED) 2-2 15/16" PLAN 3/4" = 101-8 13/16" 3 5/8" OUTDOOR KITCHEN TOP DIMENSIONS 4" THICK CONCRETE SLAB 4" THICK CONCRETE SLAB 12" THICK CONCRETE FOOTING 12" THICK CONCRETE FOOTING 4" THICK CONCRETE SLAB 4" THICK CONCRETE SLAB REVIEWED FOR ODE COMPLIANC APPROVED OCT 2 5 2016 AIL FOUNDATION PLAN 8 9 10 11 3 5/8" 1 bi P3 3 a 12 City of Tukwila BUILDING DIVISIO OUTDOOR KITCHEN 14 HOMEWOOD SUITES BY HI LTO N" Seattle/Tukwila, WA Inn Code: SEATK F RC DESIGN WORLDWIDE 311 Elm Street Sutte 600 Cincinnati, OH 45202 www.FRCH.com 513 241 3000 Owner 804.727.1757 Apple Hospitality REIT, Inc. 814 East Main Street Richmond, VA 23219 Chris Zeigler Architect 513.241.3000 FRCH Design Worldwide f: 513.241.5015 311 Elm Street, Suite 600 Cincinnati, OH 45202-2706 Mike Keifling Interior Design 513.241.3000 FRCH Design Worldwide 1: 513.241.5015 311 Elm Street, Suite 600 Cincinnati, OH 45202-2706 Raejean Downs ISSUED INFORMATION OWNER REVIEW SET: BRAND REVIEW SET: 28 April 2016 ISSUED: 19 August 2016 REVISIONS: FRCH 1 ARCHITECTURE, INC., P.C. 10520 8-19-2016 PROJECT INFORMATION INTERIOR & EXTERIOR RENOVATION Homewood Suites Tukwila 6955 Fort Dent Way Tukwila, WA 98188-2554 PROJECT NUMBER: 032609.000 SHEET INFORMATION OUtd0OARICM CITY OF TUKWILA AUG 2 3 2016 PERMIT CENTER DRAWN BY: A. Cunningham REVIEWED BY: M. Keifling SCALE: As Noted AUTHORIZED FOR: PERMIT id8002 LT -102) K J H G F E D C B A L 10 11 12 13 14 COLUMNS TO RECEIVE PAINT ABOVE TRIM PT 1 08 A. NEW STACKED STONE VENEER OVER 1/2" CEMENT BOARD ST 101 STONE PANEL STONE CORNER PLAN SECTION DETAIL 3" = 1'-0" COLUMNS AT DINING EXISTING CROWN - PRIMED AND PAINTED WOOD CAP PT 1 03 ADD 1/2" THICK FLAT STOCK AT TOP OF STONE IF STONE DEPTH GOES BEYOND BASE OF CROWN - TO RECEIVE PAINT PT 1 03 FURR OUT COLUMNS AS REQUIRED NEW STACKED STONE VENEER - DIE INTO BOTTOM OF CROWN EXISTING COLUMNS U ao NEW STACKED STONE VENEER 1 2 3 EXISTING CROWN - PRIMED AND PAINTED WOOD CAP PT 1 03 NEW WALL SCONCE AT EXISTING J -BOX LOCATION GC TO PROVIDE J -BOX EXTENSIONS TO CLEAR STONE FACE AND SECURE SCONCE INSTALL NEW STACKED STONE OVER 1/4" CEMENT BACKER BOARD OVER EXISTING GYPSUM BOARD (FURR OUT COLUMNS AS REQUIRED) (1/2" IF REPLACING GYP) WITH MIN. 1/2" -3/4" LATEX MODIFIED PORTLAND CEMENT MORTAR BED - INSTALLER RESPONSIBLE TO ORDER CORNER PIECES AS REQUIRED -- STONE SHALL WRAP ALL OUTSIDE CORNERS LT -102 STI 01 REFER TO PLAN DETAIL 3G/id8.03 FOR FINISH CORNER PT 1 03 ELEVATION COLUMNS AT DINING EXISTING CROWN - PRIMED AND PAINTED WOOD CAP PT 1 03 INSTALL NEW STACKED STONE OVER 1/4" CEMENT BACKER BOARD OVER EXISTING GYPSUM BOARD (FURR OUT COLUMNS AS REQUIRED) (1/2" IF REPLACING GYP) WITH MIN. 1/2" -3/4" LATEX MODIFIED PORTLAND CEMENT MORTAR BED - INSTALLER RESPONSIBLE TO ORDER CORNER PIECES AS REQUIRED -- STONE SHALL WRAP ALL OUTSIDE CORNERS. ST 101 REFER TO PLAN DETAIL 3GAd8.03 FOR FINISH CORNER PT 1 03 EXISTING CROWN - PRIMED AND PAINTED WOOD CAP PT 03 NEW WALL SCONCE AT EXISTING J -BOX LOCATION LT -102 GC TO PROVIDE J -BOX EXTENSIONS TO CLEAR STONE FACE AND SECURE SCONCE INSTALL NEW STACKED STONE OVER 1/4" CEMENT BACKER BOARD OVER EXISTING GYPSUM BOARD (FURR OUT COLUMNS AS REQUIRED) (1/2" IF REPLACING GYP) WITH MIN. 1/2" -3/4" LATEX MODIFIED PORTLAND CEMENT MORTAR BED - INSTALLER RESPONSIBLE TO ORDER CORNER PIECES AS REQUIRED -- STONE SHALL WRAP ALL OUTSIDE CORNERS. Eo REFER TO PLAN DETAIL 3G/id8.03 FOR FINISH CORNER PT 03 1/2" = 1'-0" ELEVATION 1/2" = 1'-0" ELEVATION 1/2" = 1'-0" 4 ELEVATION '-2 1/2" COLUMNS AT DINING 1/2" = 1'-0" NEW WALL SCONCE AT EXISTING J -BOX LOCATION GC TO PROVIDE J -BOX EXTENSIONS TO CLEAR STONE FACE AND SECURE SCONCE INSTALL NEW STACKED STONE OVER 1/4" CEMENT BACKER BOARD (1/2" IF REPLACING GYP BOARD) WITH MINIMUM 1/2" - 3/4" LATEX MODIFIED PORTLAND CEMENT MORTAR BED ST 101 5 Co FIREPLACE 6 7 NEW WALL SCONCE AT EXISTING J -BOX LOCATION GC TO PROVIDE J -BOX EXTENSIONS TO CLEAR STONE FACE AND SECURE SCONCE LT -102 INSTALL NEW STACKED STONE OVEF 1/4" CEMENT BACKER BOARD (1/2" IF REPLACING GYP BOARD)WITH MINIMUM 1/2" - 3/4" LATEX MODIFIED PORTLAND CEMENT MORTAR BED ST 1 01 PT 1 03 1 FIREPLACE 8 ELEVATION COLUMNS AT DINING 1/2" = ELEVATION PT 03 INSTALL NEW STACKED STONE OVER 5/8" CEMENT BACKER BOARD OVER EXISTING GYPSUM BOARD WITH MINIMUM 1/2" - 3/4" LATEX MODIFIED PORTLAND CEMENT MORTAR BED ST 101 PT 1 03 ELEVATION 1/2" = 1'-0" EXISTING CROWN - PRIMED AND PAINTED WOOD CAP PT 1 03 INSTALL NEW STACKED STONE OVER 1/4" CEMENT BACKER BOARD OVER EXISTING GYPSUM BOARD (FURR OUT COLUMNS AS REQUIRED) (1/2" IF REPLACING GYP) WITH MIN. 1/2" -3/4" LATEX MODIFIED PORTLAND CEMENT MORTAR BED - INSTALLER RESPONSIBLE TO ORDER CORNER PIECES AS REQUIRED -- STONE SHALL WRAP ALL OUTSIDE CORNERS. ST 101 PT 1 03 COLUMNS AT DINING EXISTING CROWN - PRIMED AND PAINTED WOOD CAP PT 1 03 INSTALL NEW TV - CONTRACTOR TO COORDINATE WIRING WITH TILE INSTALLATION ao EXISTING FIREPLACE INSERT TO REMAIN 1/2" = 1'-0" PT 1 03 INSTALL NEW STACKED STONE OVER 5/8" CEMENT BACKER BOARD OVER EXISTING GYPSUM BOARD WITH MINIMUM 1/2" - 3/4" LATEX MODIFIED PORTLAND CEMENT MORTAR BED ST 101 ELEVATION 1/2" = 9 10 FIREPLACE @ LODGE (ART -184) EXISTING FIREPLA INSERT TO REMAI REV.EWED FOR ECODE OMPLIANCE APROVED 11 12 13 OC 2 5 2016 Cit of Tukwila • G DIVISION FIREPLACE @ LOBBY 14 HOMEWOOD .. SUITES BY HILTO N' Seattle/Tukwila, WA Inn Code: SEATK FRC DESIGN WORLDWIDE 311 Elm Street Suite 600 Cincinnati, OH 45202 www.FRCH.com 513 241 3000 Owner 804.727.1757 Apple Hospitality REIT, Inc. 814 East Main Street Richmond, VA 23219 Chris Zeigler Architect 513.241.3000 FRCH Design Worldwide f: 513.241.5015 311 Elm Street, Suite 600 Cincinnati, OH 45202-2706 Mike Keifling Interior Design 513.241.3000 FRCH Design Worldwide f: 513.241.5015 311 Elm Street, Suite 600 Cincinnati, OH 45202-2706 Raejean Downs ISSUED INFORMATION OWNER REVIEW SET: BRAND REVIEW SET: 28 April 2016 ISSUED: 19 August 2016 REVISIONS: FRCH 1 ARCHITECTURE, INC., P.C. 10520 REG - JA S DENN 0 i •LETON A E OF VPS NGTON 8-19-2016 PROJECT INFORMATION INTERIOR & EXTERIOR RENOVATION Homewood Suites Tukwila 6955 Fort Dent Way Tukwila, WA 98188-2554 PROJECT NUMBER: 032609.000 SHEET INFORMATION Interior Details: Stone VeneiiVED CITY OF TUKWILA AUG 2 3 2016 PERMIT CENTER DRAWN BY: A, Cunningham REVIEWED BY: M.Keifling, R.Downs SCALE: As Noted AUTHORIZED FOR: PERMIT id8 10 11 12 13 14 - ® A s J 1 2 3 4 5 6 EXISTING ROOF CONSTRUCTION - FIELD VERIFY DIRECTION AND LOCATION OF EXISTING CEILING JOISTS/ RAFTERS, CONTACT ARCHITECT IF DIFFERENT THAN SHOWN EXISTING TRIM TO REMAIN - PATCH, REPAIR AND PAINT AS REQUIRED FROM CONSTRUCTION CONTINUOUS BEAD OF SEALANT AT JOINT TO EXISTING BEAM STUCCO FINISH ON METAL LATH - FINISH AND COLOR TO MATCH EXISTING, FIELD VERIFY (2) LAYERS AIR AND MOISTURE BARRIER INSTALL PER MANUF. SPECIFICATIONS EXISTING TERRACE COLUMN BEYOND EXISTING TERRACE COLUMN BEYOND STUCCO FINISH ON METAL LATH - FINISH AND COLOR TO MATCH EXISTING, FIELD VERIFY CONTINUOUS BEAD OF SEALANT AT JOINT TO EXISTING BEAM GALVANIZED METAL FLASHING AT WINDOW HEAD PROPOSED FRENCH DOOR STYLE WINDOW - FINISH AND STYLE TO MATCH EXISTING, FIELD VERIFY SIZE OF OPENING DETAIL 1 1/2" = 1'-0" EXISTING TERRACE COLUMN BEYOND AZEK OR SIMILAR PVC PROFILE TRIM TO MATCH EXISTING, PAINT TO MATCH EXISTING CONTINUOUS BEAD OF SEALANT AT JOINT TO — EXISTING BEAM T/ FIRST FLOOR SLAB FIELD VERIFY APPROX. LINE OF EXISTING WALK DETAIL 1 1/2" = 1'-0" v-� a 4 . • a a : 4 a • d A : 4 4 a A . 4• 4 d 4 d d • a 1'-0" DEMO EXISTING STUCCO AND SHEATHING DOWN TO EXISTING CEILING JOIST, INSTALL NEW GYP. BOARD, FINISH TO MATCH FITNESS CENTER, REFER ALSO TO FINISH PLAN EXISTING TRIM AT BEAM TO REMAIN, PRIME AND PAINT TO MATCH FITNESS CENTER - REFER ALSO TO FINISH PLAN WALL CONSTRUCTION TO MATCH EXISTING, FIELD VERIFY - 5/8" TYPE 'X' GYP. BOARD OVER 1/2" PLYWOOD SHEATHING ON 2x6 WOOD STUD FRAMING WITH 5-13 BATT INSULATION EXISTING TERRACE COLUMN BEYOND 5/8" TYPE 'X' GYP. BOARD OVER (2) 2x12 WOOD HEADER 5/8" TYPE 'X' GYP. BOARD WINDOW HEAD FITNESS CENTER EXISTING TERRACE COLUMN BEYOND PROPOSED FRENCH DOOR STYLE WINDOW - FINISH AND STYLE TO MATCH EXISTING, FIELD VERIFY SIZE OF OPENING WOOD TRIM TO MATCH EXISTING RESILENT FLOORING - REFER ALSO TO FINISH PLAN AND INTERIOR SPECIFICATIONS FOR MORE INFORMATION 1/2" CONT. COMPRESSIBLE FILLER W/ CONT. NON -SHRINK SEALANT WINDOW SILL 10A FITNESS CENTER id8.04 w EXISTING TERRACE COLUMN BEYOND STUCCO FINISH ON METAL LATH - FINISH AND COLOR TO MATCH EXISTING, FIELD VERIFY CONTINUOUS BEAD OF SEALANT AT JOINT TO EXISTING BEAM GALVANIZED METAL FLASHING AT WINDOW AZEK OR SIMILAR PVC PROFILE TRIM TO MATCH EXISTING, PAINT TO MATCH EXISTING PROPOSED FRENCH DOOR STYLE WINDOW - FINISH AND STYLE TO MATCH EXISTING, FIELD VERIFY SIZE OF OPENING DETAIL 1 1/2" = 1'-0" BLOCK IN AREA BETWEEN CEILING JOISTS TO ALLOW FOR NEW WOOD STUD WALL BELOW - FIELD VERIFY DIRECTION AND LOCATION OF EXISTING CEILING JOISTS, CALL ARCHITECT IF DIFFERENT THAN SHOWN DEMO EXISTING STUCCO AND SHEATHING DOWN TO EXISTING CEILING JOIST, INSTALL NEW GYP. BOARD, FINISH TO MATCH FITNESS CENTER, REFER ALSO TO FINISH PLAN 5/8" TYPE 'X' GYP. BOARD - PRIME AND PAINT TO MATCH, REFER TO FINISH PLANS FOR MORE INFORMATION DETAIL 1 1/2" = 1'-0" WALL CONSTRUCTION TO MATCH EXISTING, FIELD VERIFY - 5/8" TYPE 'X' GYP. BOARD OVER 1/2" PLYWOOD SHEATHING ON 2x6 WOOD STUD FRAMING WITH 5-13 BATT INSULATION 5/8" TYPE 'X' GYP. BOARD OVER (2) 2x12 WOOD HEADER 5/8" TYPE 'X' GYP. BOARD INTERIOR WOOD TRIM TO MATCH EXISTING - FIELD VERIFY WINDOW JAMB FITNESS CENTER STUCCO FINISH ON METAL LATH - FINISH AND COLOR TO MATCH EXISTING, FIELD VERIFY (2) LAYERS AIR AND MOISTURE BARRIER - INSTALL PER MANUF. SPECIFICATIONS WALL CONSTRUCTION TO MATCH EXISTING, FIELD VERIFY - 5/8" GYP. BOARD OVER 1/2" PLYWOOD SHEATHING ON 2x6 WOOD STUD FRAMING WITH 5-13 BATT INSULATION EXTERIOR WALL TOP PLATE 013 FITNESS CENTER REVIEWED FOR CODE COMPLIANCE APPROVED OCT 2 5 2016 City of Tukwila BUILDING DIVISION 8 9 10 11 12 13 14 HOMEWOOD SIT � t BY HILTON" Seattle/Tukwila, WA Inn Code: SEATK FRC DESIGN WORLDWIDE 311 Elm Street Suite 600 Cincinnati, OH 45202 www.FRCH.com 513 241 3000 Owner 804.727.1757 Apple Hospitality REIT, Inc. 814 East Main Street Richmond, VA 23219 Chris Zeigler Architect 513.241.3000 FRCH Design Worldwide f: 513.241.5015 311 Elm Street, Suite 600 Cincinnati, OH 45202-2706 Mike Keifling Interior Design 513.241.3000 FRCH Design Worldwide f: 513.241.5015 311 Elm Street, Suite 600 Cincinnati, OH 45202-2706 Raejean Downs ISSUED INFORMATION OWNER REVIEW SET: BRAND REVIEW SET: 17 June 2016 ISSUED: 19 August 2016 REVISIONS: ................................................................................................................................... ................................................................................................................................... FRCH 1 ARCHITECTURE, INC., P.C. 10520 REG .I T JA S DENN 0 i , LETON A E OF ,S NGTON 8-19-2016 PROJECT INFORMATION INTERIOR & EXTERIOR RENOVATION Homewood Suites Tukwila 6955 Fort Dent Way Tukwila, WA 98188-2554 PROJECT NUMBER: 032609.000 SHEET INFORMATION Wall Details_ RECEIVED CITY OF TUKWILA AUG 2 3 2016 PERMIT CENTER DRAWN BY: B. Grannan REVIEWED BY: M. Keifling SCALE: As Noted AUTHORIZED FOR: PERMIT id8 D 0 4 K J H G F E D C B I=> USER: MKEIFLING L 4 5 6 7 8 9 10 11 12 13 14 CONSTRUCTION NOTES: 1. ALL CABINETS AND DRAWERS TO HAVE SAME KEYED LOCKS 2. ALL EXPOSED SURFACES OF WOOD CONSTRUCTION TO BE P. LAM. FINISH. ALL DOORS, SHELVES, DRAWERS, ENDCAPS TO HAVE 1 MM EDGEBAND TO MATCH LAMINATE 3. INTERIOR CABINETS TO BE BLACK MELAMINE 4. ALL ELECTRICAL TO BE RUN IN CAVITY AND BACK OF MODULES TO BE PARTIAL (NOT FULL BACK TO ALLOW FOR MODULES TO BE EASILY SLID IN TO PLACE AFTER ELECTRICAL IS COMPLETE 5. DRAWER CONSTRUCTION -SIDES OF BOX ARE FRENCH DOVETAILED INTO FRONT, BACK IS THROUGH DADOED INTO SIDES, DRAWER BOTTOM IS MELAMINE, SIDES WOOD 6. ALL DRAWER AND SHELF GLIDES TO BE FULL EXTENSION SOFT CLOSE UNITS - KV8450 OR EQUAL 7. MILLWORK MANUFACTURER TO VERIFY ALL COMPUTER HARDWARE SIZES BEFORE BEGINNING 8. ALL EQUIPMENT TO BE SUPPLIED BY OWNER THROUGH HILTON TRANSACTION TOP ST 1 02 WOOD FRAME WD j 01 N v 9" FABRICATOR TO PROVIDE WIRE MANAGEMENT ACCESS WOOD INSET WDI 02 ALL SURFACES- DOORS AND DRAWERS PL 01 WOOD FRAME WDI 01 PL 01 SLIDING PRINTER TRAY ON HEAVY DUTY SIDE MOUNTED GLIDES PL 101 SECTION 1 1/2" = 1'-0" TRANSACTION TOP ST 1 02 WOOD FRAME WDI 01 N GV N CV r Jr. 3/4" 5 1/4" 2'-0" 9" FABRICATOR TO PROVIDE WIRE MANAGEMENT ACCESS WOOD INSET WDI 02 ALL SURFACES- DOORS AND DRAWERS PL 101 WOOD FRAME WDI 01 SLIDING PRINTER TRAY ON HEAVY DUTY SIDE MOUNTED GLIDES PL 101 SECTION 1 1/2" = 1'-0" PL 01 MW -01 FRONT DESK CV 3/4" 51/4" 2'-0" 3'-0" 3'-0" 2 1/2" GROMMET DIRECTLY ABOVE QUAD OUTLET BELOW QUAD AND DUPLEX OUTLETS BY OTHERS WIRE GROMMETS - 2 1/2" DIA. PRINTER SHELF ON FULL EXTENSION DRAWER GLIDE. SHELF HAS SIDES ONLY, NO FRONT OR BACK WOOD RAIL TO SUPPORT BRACKET FOR FILES LOCKABLE FILE DRAWER ON FULL EXTENSION DRAWER GLIDES. PROVIDE BRACKET HOLDER FOR HANGING FILES. 3/4" THICK STONE TOP WITH BUILT UP EDGES. EDGES TO BE SQUARED WITH SLIGHT CHAMFER. POLISH AND EASE EDGES. ST 02 TWO UTILITY DRAWERS WITH FULL EXTENSION GLIDES AND PULL LOCKABLE CASH DRAWER WITH FULL EXTENSION GLIDES AND PULL PARTIAL DOOR FOR ACCESS TO TRASH RECEPTACLE WITH SOFT CLOSE CONCEALED HINGES VENT SLOT MW -01 FRONT DESK M (WDI 01 ST 1 02 1 8" WDI 01 WD 1 02 8" ST 1 02 MT 01 ACCESSIBLE TRANSACTION TOP 0 M v r 5'-01/2" 7 1/2" 6 1/2" J 00 N 0 T M a 00 00 FLAT SCREEN MONITOR BY OWNER (DRAWN 15.2"H x 17.6"W x 6.1"D) OUTLET AND PHONE/DATA PORTS COMPUTER PRINTER BY OWNER (DRAWN 12.4"H x 17.6"W) LOCKABLE CASH DRAWER WITH FULL EXTENSION GLIDES AND PULL COMPUTER CPU UNIT BY OWNER (DRAWN 15.0"H x 3.9"W x 13.2"D) ON SHELF WITH FULL EXTENSION GLIDES - SOFT CLOSE TRASH CAN BY OWNER (DRAWN 12.5"H x 8.25"W x 14.25"D) PLASTIC LAMINATE SURFACE ON 3/4" SUBSTRATE (TYP.) LOCKABLE FILE DRAWER ON FULL EXTENSION DRAWER GLIDES W/ SOFT CLOSE. PROVIDE BRACKET HOLDER FOR HANGING FILES VENT SLOT 1'-3 1/4" 1'-11 3/4" 1'-2" 2'-0 3/4" / 4'-01/2" POD W/ ACCESSIBLE TOP SERVICE SIDE ELEVATION 1 1/2" = 1'-0" (WDI02F— I MT101 M t 5'-01/2" N 8" 8" ISTI021 CV N WDI 01 1 4'-11 1/2" 6 1/2" 5'-01/2" 3'-101 /2" POD'A' 7 1/2" MONITOR CUTOUT n L PLAN 1311711110 1 I I I I I I I L_ POD 'B' I0 TYPICAL POD ELEVATION WD 02 5,-3" MW -01 FRONT DESK 8" 1 ST 1 02 1 JWDI01j N N CV N 0 M ACCESSIBLE COUNTER 5'-1" ELEVATION 3/4" = 4,-5" 10" MW -01 FRONT DESK POD 'B' L_ POD 'A' ACCESSIBLE 3/4" = AIL 1 b Oix3 30x48 CLEAR FLOOR AREA REVIEWED FOR CODE COMPLIANC APPROMED 4. OCT 2 5 2016 COUNTER City of Tukwila BUILDING DIVISION MW -01 FRONT DESK 2 3 4 5 6 7 8 9 10 11 12 13 14 HOMEWOOD .. f Seattle/Tukwila, Inn Code: i SITES BY HILTON" WA SEATK FRC DESIGN WORLDWIDE 311 Elm Street Suite 600 Cincinnati, OH 45202 www.FRCH.com 513 241 3000 Owner 804.727.1757 Apple Hospitality REIT, Inc. 814 East Main Street Richmond, VA 23219 Chris Zeigler Architect 513.241.3000 FRCH Design Worldwide f: 513.241.5015 311 Elm Street, Suite 600 Cincinnati, OH 45202-2706 Mike Keifling Interior Design 513.241.3000 FRCH Design Worldwide 1: 513.241.5015 311 Elm Street, Suite 600 Cincinnati, OH 45202-2706 Raejean Downs ISSUED INFORMATION OWNER REVIEW SET: BRAND REVIEW SET: 28 April 2016 ISSUED: 19 August 2016 REVISIONS: ............................................................................................................:...................... FRCH 1 ARCHITECTURE, INC., P.C. 10520 REG ',' JA S DENN 1 ='LETON A E OF W SNGTON .�J 8-19-2016 PROJECT INFORMATION INTERIOR & EXTERIOR RENOVATION Homewood Suites Tukwila 6955 Fort Dent Way Tukwila, WA 98188-2554 PROJECT NUMBER: 032609.000 SHEET INFORMATION Interior Millwork: MW-01FErAllilttl§k CITY OF TUKWILA AUG 2 3 2016 PERMIT CENTER DRAWN BY:. A. Cunningham REVIEWED BY: M. Keifling SCALE: As Noted AUTHORIZED FOR: PERMIT © 2016 This drawing, printed or otherwise, is the copyrighted property of FRCH Design Worldwide and FRCH/Architecture, Inc., P.C. The drawing may not be used, reproduced or copied without the permission of FRCH Design Worldwide or FRCH/Architecture, Inc., P.0 LAYOUT: id8.52 USER: MKEIFLING K J H G F E D C B A 3 4 5 6 7 8 9 10 11 12 13 14 3/4" STONE COUNTER TOP - EASE ALL EXPOSED EDGES TO MIN 1/8" RADIUS 3/4" CABINET CONSTRUCTION SECTION 3" = 3/4" CABINET CONSTRUCTION SOLID WOOD DOOR WITH INSET WODO PANEL 1 1/2" SECTION Half Full Scale HWTui_8.52 1" WOOD FILLER HWTui_8.52 1/2" DETAIL Full Scale o N ix WOOD CAP STAINED TO MATCH EXISTING PANTRY BUFFET CABINETRY 1/4" REVEAL, STAINED TO MATCH EXISTING PANTRY BUFFET CABINETRY WALLCOVERING OVER NEW 5/8" GYP. BOARD ON FRONT -INSTALL WALLCOVERING PRIOR TO ADDING WOOD CAP 3 5/8" 25 Ga. METAL STUDS DECORATIVE WALL CAP TYPICAL CUT OUT, TYPICAL OF BOTH OPENINGS 0 o v 8'-6" VIF r SB36 ELEVATION 1/2" = 1'-0" B30 EMPLOYEE LOUNGE HD 117 PLAN 1/2" = 1'-0" STAINLESS STEEL TRASH RING, TYPICAL H OPENINGS, x 7/16" METAL ATING 3-9613 ■ • �� W3018 W3630 W3015 • BUSSING BIN WOOD OF BOT 12" x 2' SoCAL FABRIC 626-81 120 a WOOD ■ ■ ■ N TO BE PROVIDED BY OWNER GRAIN Chris Zeigler Architect 513.241.3000 Fes:., -', F TRASH CAN BY OTHERS i TRASH CAN BY OTHERS �' DIMENSIONS: RUBBERMAID GLUTTON ? 56ga1. _\__.. id8.5 Raejean Downs ISSUED INFORMATION 25.5" X 22.75" W X 31.125" H 25.5" X 22.75" W X 31.125" H 28 April 2016 3/4" M PLYWO FOR AL CONSTI LEVELE O D REVISIONS: FRCH 1 ARCHITECTURE, INC., P.C. k�w 10520 REG • c'1 JA S DENN , i'• LETON A EOFW SiNGTON 8-19-2016 PROJECT INFORMATION \.`.\ RENOVATION //7 6955 Fort Dent Way MICRO PROJECT NUMBER: 032609.000 • 0 Interior Millwork: MW -02 Bussing Station MW -03 Guest Laundry EmployeeAl-otl,t gabs. // DRAWN BY: kli un nghar016 PERMIT CENTER REVIEWED BY: M. Keifling SCALE: As Noted AUTHORIZED FOR: PERMIT id8052 R/F o • ..` z 7 7 `. ,' H. 0 r SB36 ELEVATION 1/2" = 1'-0" B30 EMPLOYEE LOUNGE HD 117 PLAN 1/2" = 1'-0" STAINLESS STEEL TRASH RING, TYPICAL H OPENINGS, x 7/16" METAL ATING 3-9613 ■ • �� FRC DESIGN WORLDWIDE 311 Elm Street Suite 600 Cincinnati, OH 45202 www.FRCH.com 513 241 3000 • BUSSING BIN WOOD OF BOT 12" x 2' SoCAL FABRIC 626-81 120 a WOOD ■ ■ ■ N TO BE PROVIDED BY OWNER GRAIN Chris Zeigler Architect 513.241.3000 Fes:., -', F TRASH CAN BY OTHERS i TRASH CAN BY OTHERS DIMENSIONS: RUBBERMAID GLUTTON 56ga1. DIMENSIONS: RUBBERMAID GLUTTON ? 56ga1. 311 Elm Street, Suite 600 id8.5 Raejean Downs ISSUED INFORMATION 25.5" X 22.75" W X 31.125" H 25.5" X 22.75" W X 31.125" H 28 April 2016 3/4" M PLYWO FOR AL CONSTI LEVELE 19 August 2016 REVISIONS: SECTION 1" = 1'-0" 2-6" 2'-6" 1 5'-0" 5'-1" 1 MW -02 BUSSING STATION ,RINE GRADE ODOR EQUAL L CABINETRY RUCTION R FEET A. 0 CV EMPLOYEE LOUNGE 2'-4 1/2" 3/4" tY COUNTERTOP a.■ TRASH CAN BY OTHERS DIMENSIONS: RUBBERMAID GLUTTON 56ga1. 22.75" W X 31.125" H J � ■ r; 3/4" STONE COUNTERTOP SURFACE WITH EASED EDGE TO MATCH EXISTING PANTRY COUNTERTOP HD 1 04 CUSTOM GRADE BASE CABINET MILLWORK STAINED TO MATCH EXISTING PANTRY INTERIOR PANELS LAMINATED TO MATCH WOOD FINISH OR BLACK MELAMINE OPEN A t v CV CC w J N 2-6" „1 SECTION 1" = 1'-0" PLAN 1/2" = 1'-0" BACKSPLASH, FINISH TO MATCH COUNTERTOP HIGH PRESSURE PLAM COUNTERTOP SURFACE EDGING W/ EASED EDGE PL 101 PL 1 1x AND 2x FRT SOLID WOOD BLOCKING AS REQUIRED 3/4" PLYWOOD BRACKET, COVER ALL EXPOSED EDGES WITH HIGH PRESSURE PLAM TO MATCH COUNTERTOP, TYP. (BEYOND) PL 01 MW -03 GUEST LAUNDRY 0 BUSSING BIN, BY OTHERS, TO SIT ATOP COUNTER COUNTERTOP, 4" BACKSPLASH, AND 4" SIDESPLASHES TO MATCH EXISTING PANTRY COUNTERTOP STONE HD 04 WOOD CABINET STAINED TO MATCH EXISTING PANTRY BUFFET CABINETRY NEW PARTIAL HEIGHT WALL, WITH WOOD BASE TO MATCH EXISTING FILLER, TYP. OF BOTH SIDES, FIELD VERIFY SIZE .• 4 7/8" 2-6" 2-6" 4 7/8" 1/2"•, EQ. EQ. 1/2" 5'-1" PLAN SECTION 1/2" = 1'-0" 1"X 3" BLOCKING OUTLINE OF TRASH CANS 1/2" FILLER 1/4" REVEAL COUNTERTOP ABOVE BUSSING STATION OUTLINE OF CABINETRY BELOW —4- -1-- -0- -4— _0— GENERAL MILLWORK NOTES: a. b. c. d. DRAWINGS PROVIDED INDICATE DESIGN INTENT ONLY - ALL DIMENSIONS MUST BE VERIFIED PRIOR TO PREPARING SHOP DRAWINGS AND/OR ANY FABRICATION MILLWORKER MUST SUBMIT SHOP DRAWINGS OF ALL MILLWORK PRIOR TO FABRICATION REFER TO MATERIAL REFERENCE BINDER FOR ADDITIONAL INFORMATION ALL MILLWORK TO BE PER 'ARCHITECTURAL WOODWORK INSTITUTE' PREMIUM GRADE STANDARD O KEYNOTES: INSTALL NEW CABINETRY, COUNTERTOP, AND BACKSPLASH - PROVIDE NEW APPLICANCES, ALLOW ROOM FOR MICROWAVE. USE FOLLOWING SELECTIONS AS BASIS OF DESIGN: SUPPLIER: LOWES FINISH: KITCHEN CLASSIC, PORTLAND OAK STANDARD OVERLAY, RAISED PANEL FINISH: MEDIUM OAK LAMINATE TOPS: LOWES BELANGER, OURO ROMANO UNDERCABINET MICROWAVE WITH RECIRCULATING FAN NEW FAUCET USE FOLLOWING SELECTIONS AS BASIS OF DESIGN: SUPPLIER: AMERICAN STANDARD MODEL NAME: MONTERREY TOP MOUNT KITCHEN FAUCET - WRIST HANDLES AND SPARY MODEL #: 6408.171 FINISH: POLISHED CHROME (002) NEW KITCHEN SINK USE FOLLOWING SELECTIONS AS BASIS OF DESIGN: SUPPLIER: AMERICAN STANDARD MODEL NAME: ADA DOUBLE BOWL 33" STAINLESS STEEL KITCHEN SINK MODEL #: 24DB.332284.290 —0— REVIEWED FOR CODE COMPLIANCE APPROVED OCT 2 5 2016 City of Tukwila BUILDING DIVISION 1 2 3 4 5 6 7 8 9 10 11 12 13 14 HOMEWOODSUITES .... . ., �...BY HILTON" Seattle/Tukwila, WA Inn Code: SEATK FRC DESIGN WORLDWIDE 311 Elm Street Suite 600 Cincinnati, OH 45202 www.FRCH.com 513 241 3000 WOOD 11, - a WOOD N. ~ -,GRAIN 814 East Main Street GRAIN Chris Zeigler Architect 513.241.3000 FRCH Design Worldwide f: 513.241.5015 MW -03 GUEST LAUNDRY 0 BUSSING BIN, BY OTHERS, TO SIT ATOP COUNTER COUNTERTOP, 4" BACKSPLASH, AND 4" SIDESPLASHES TO MATCH EXISTING PANTRY COUNTERTOP STONE HD 04 WOOD CABINET STAINED TO MATCH EXISTING PANTRY BUFFET CABINETRY NEW PARTIAL HEIGHT WALL, WITH WOOD BASE TO MATCH EXISTING FILLER, TYP. OF BOTH SIDES, FIELD VERIFY SIZE .• 4 7/8" 2-6" 2-6" 4 7/8" 1/2"•, EQ. EQ. 1/2" 5'-1" PLAN SECTION 1/2" = 1'-0" 1"X 3" BLOCKING OUTLINE OF TRASH CANS 1/2" FILLER 1/4" REVEAL COUNTERTOP ABOVE BUSSING STATION OUTLINE OF CABINETRY BELOW —4- -1-- -0- -4— _0— GENERAL MILLWORK NOTES: a. b. c. d. DRAWINGS PROVIDED INDICATE DESIGN INTENT ONLY - ALL DIMENSIONS MUST BE VERIFIED PRIOR TO PREPARING SHOP DRAWINGS AND/OR ANY FABRICATION MILLWORKER MUST SUBMIT SHOP DRAWINGS OF ALL MILLWORK PRIOR TO FABRICATION REFER TO MATERIAL REFERENCE BINDER FOR ADDITIONAL INFORMATION ALL MILLWORK TO BE PER 'ARCHITECTURAL WOODWORK INSTITUTE' PREMIUM GRADE STANDARD O KEYNOTES: INSTALL NEW CABINETRY, COUNTERTOP, AND BACKSPLASH - PROVIDE NEW APPLICANCES, ALLOW ROOM FOR MICROWAVE. USE FOLLOWING SELECTIONS AS BASIS OF DESIGN: SUPPLIER: LOWES FINISH: KITCHEN CLASSIC, PORTLAND OAK STANDARD OVERLAY, RAISED PANEL FINISH: MEDIUM OAK LAMINATE TOPS: LOWES BELANGER, OURO ROMANO UNDERCABINET MICROWAVE WITH RECIRCULATING FAN NEW FAUCET USE FOLLOWING SELECTIONS AS BASIS OF DESIGN: SUPPLIER: AMERICAN STANDARD MODEL NAME: MONTERREY TOP MOUNT KITCHEN FAUCET - WRIST HANDLES AND SPARY MODEL #: 6408.171 FINISH: POLISHED CHROME (002) NEW KITCHEN SINK USE FOLLOWING SELECTIONS AS BASIS OF DESIGN: SUPPLIER: AMERICAN STANDARD MODEL NAME: ADA DOUBLE BOWL 33" STAINLESS STEEL KITCHEN SINK MODEL #: 24DB.332284.290 —0— REVIEWED FOR CODE COMPLIANCE APPROVED OCT 2 5 2016 City of Tukwila BUILDING DIVISION 1 2 3 4 5 6 7 8 9 10 11 12 13 14 HOMEWOODSUITES .... . ., �...BY HILTON" Seattle/Tukwila, WA Inn Code: SEATK FRC DESIGN WORLDWIDE 311 Elm Street Suite 600 Cincinnati, OH 45202 www.FRCH.com 513 241 3000 Owner 804.727.1757 Apple Hospitality REIT, Inc. 814 East Main Street Richmond, VA 23219 Chris Zeigler Architect 513.241.3000 FRCH Design Worldwide f: 513.241.5015 311 Elm Street, Suite 600 Cincinnati, OH 45202-2706 Mike Keifling Interior Design 513.241.3000 FRCH Design Worldwide f: 513.241.5015 311 Elm Street, Suite 600 Cincinnati, 01-1 45202-2706 Raejean Downs ISSUED INFORMATION OWNER REVIEW SET: BRAND REVIEW SET: 28 April 2016 ISSUED: 19 August 2016 REVISIONS: FRCH 1 ARCHITECTURE, INC., P.C. k�w 10520 REG • T JA S DENN , i'• LETON A EOFW SiNGTON 8-19-2016 PROJECT INFORMATION INTERIOR & EXTERIOR RENOVATION Homewood Suites Tukwila 6955 Fort Dent Way Tukwila, WA 98188-2554 PROJECT NUMBER: 032609.000 • SHEET INFORMATION Interior Millwork: MW -02 Bussing Station MW -03 Guest Laundry EmployeeAl-otl,t gabs. CITY OF TUKWILA DRAWN BY: kli un nghar016 PERMIT CENTER REVIEWED BY: M. Keifling SCALE: As Noted AUTHORIZED FOR: PERMIT id8052 K J H G F E D C B A L 7 8 9 10 11 12 13 14 FACE OF BACK WALLOF—�, RECEPTION AREA. PANELS TO BE GLUED DIRECTLY TO SURFACE. DETAIL 1 1/2" = 1'-0" io 7 1/8"+/ - WOOD VALANCE WOOD TRIM STAINED TO MATCH WD101 WOOD TRIM BEYOND 1x2 WOOD TRIM STAINED TO MATCH GLUED DIRECTLY TO WOOD INSET PANEL WD101 WOOD INSET STAINED TO MATCH WD 102 FIXED PANEL FRONT DESK SCREEN MINIMIZE AS HARDWARE ALLOWS 18 ga. METAL PLATE BLOCKING 3"X3" ANGLE BRACKET, FASTEN TO EXISTING STRUCTURE AT BOTH ENDS AND 24" 0.C. AL CLG. HT. VERIFY IN FIELD CD WOOD VALANCE STAINED • TO MATCH WD101 TOP HUNG SLIDING DOOR HARDWARE TRACK: HAFELE HAWA JUNIOR 160B WOOD TRIM STAINED TO MATCH WD101 WOOD TRIM BEYOND SUDING WOOD PANEL BEYOND 1x2 WOOD TRIM STAINED TO MATCH WD 101 GLUED DIRECTLY TO WOOD INSET PANEL WOOD INSET STAINED TO MATCH WD 102 1 3/4" THICK, STAINED WOOD SLIDING DOORS W/ 3/8" THICK WOOD INSET DETAIL Full Scale SLIDING DOOR SECTION 2A id8.53 1 AIL CD to • EXISTING GYPSUM BOARD AT CORRIDOR, FIELD VERIFY HEIGHT WOOD TRIM ON BOTH SIDES, RECEIVE PAINT PT 103 ACRYUC PANEL REFER TO INTERIOR SPECIFICATIONS A 101 WOOD TRIM ON BOTH SIDES, RECEIVE PAINT PT 103 5/8" GYP. BD. ON EA. SIDE OF WOOD BLOCKING WITH WOOD BASE, RECEIVE PAINT PT 103 DETAIL 1 1/2" = 1'-0" r.n U -II 2-1" 2 TEMPERED GLASS PANEL CABINETS PAINTED PT 103 TEMPERED GLASS PANEL CUP PULL HARDWARE, STAINLESS STEEL FINISH HD 101 12v BI -PIN BASE G4 LAMP, 20W MAX, RECESSED W/ WHITE FINISH TYP. OF CUBBIES TILE BACKSPLASH ACCENT FINISH T 104 °ADJUSTABLE SHELF ST 105 CUP PULL HARDWARE, STAINLESS STEEL FINISH HD 101 TOE KICK/ BASE MT 101 1'-9" 2'-0" TOP HUNG SLIDING DOOR HARDWARE BEHIND VALANCE: HAFELE HAWA JUNIOR 160B WOOD VALANCE STAINED TO MATCH WD 101 WOOD INSET STAINED WDI 02 TO MATCH WOOD FRAME STAINED WD101 TO MATCH STAINLESS STEEL 48" STRAIGHT DOOR PULL WOOD INSET STAINED WD 102 TO MATCH RIGHT STILE TO BE 1" WIDER THAN TYPICAL PANELS IN ORDER TO MAINTAIN VISIBLE 4" STILE WHEN SUDING DOOR IS FULLY CLOSED TO ALLOW FOR OVERLAP ELEVATION 1/2" = v 6" AT FRONT DESK v TRIM TO HOLD RESIN IN PLACE - BUTT JOINT FINISH TO BE SMOOTH 1/2" AT FRONT DESK, DECORATIVE 1/2" THICK WOOD PANEL WD 102 INSET INTO WOOD FRAME. ADD ANY ADDI11ONAL SUPPORT AS RECOMMENDED BY MANUFACTURER DETAIL 3" = 1'-0" EQ. 2" EQ. FRONT DESK 3'-31/2" 3'-3 3/8" TYP 3'-3 3/8" TYP. 9'-101/4" +/- / FIELD VERIFY 2" 1'-8" 2" v GV CV FRONT DESK SCREEN FRC H DESIGN WORLDWIDE 311 Elm Street Suite 600 Cincinnati, OH 45202 www.FRCH.com 513 241 3000 CV` / i /\ BRAND REVIEW SET: 28 APRIL 2016 ---_____________.)/ / REVISIONS: `Y / 4 FRCH 1 ARCHITECTURE, INC., P.C. 10520 JA REG ' T S DENN " '' LETON A EOFW'S°`NGTON 8-19-2016 7 7 \ \ \ \ DRAWN BY: CITE A. CunninghamOnVV1LA AUG 2 3 2016 REVIEWED BY: M. (Keifling SCALE: PER NIt0 ENTER AUTHORIZED FOR: PERMIT • / / / / , i CV 2" / y \ (1) SUDING / / \/ \ cy \/ —=- DOOR PANEL . / / _ = FIXED PANEL 12J / 7 FDD PANEL id8.53 r „ \ CVy` FRONT DESK 3'-31/2" 3'-3 3/8" TYP 3'-3 3/8" TYP. 9'-101/4" +/- / FIELD VERIFY 2" 1'-8" 2" v GV CV FRONT DESK SCREEN TEMPERED GLASS PANEL PAINT FINISH PT 103 / / / / / / TILE BACKSPLASH ACCENT FINISH T 1 04 PAINTED FINISH PT 103 1ST1051 CUP PULL HARDWARE, STAINLESS STEEL FINISH HD 101 CAM LOCK HARDWARE, STAINLESS STEEL FINISH 2-0” 2-0" 4'-2" FIELD VERIFY ELEVATION 1" = 1'-0" AIL STAINED FINISH AT LOWER CABINETS WD101 TOE KICK/ BASE MT101 MW -04 9A SUITE SHOP id8.53 TRIM TO HOLD RESIN IN PLACE - BUTT JOINT FINISH TO BE SMOOTH 6" AT BUSINESS CENTER 4" 4" BUSINESS CENTER 0 CD AT FRONT DESK SOLID WOOD FRAME WITH 1/2" DEEP GROOVE ROUTED OUT TO HOLD DECORATIVE RESIN PANEL AT HOME OFFICE, DECORATIVE 1/2" THICK RESIN PANEL INSET INTO WOOD FRAME. ADD ANYADDI11ONAL SUPPORT AS RECOMMENDED BY MANUFACTURER UNE OF FRAME BELOW PANELS FRONT DESK AND BUSINESS CENTER SCREEN HEIGHT OF EXISTING OPENING 6" 51-8"6" i u y FRC H DESIGN WORLDWIDE 311 Elm Street Suite 600 Cincinnati, OH 45202 www.FRCH.com 513 241 3000 CV` / i /\ BRAND REVIEW SET: 28 APRIL 2016 \ REVISIONS: `Y 4 FRCH 1 ARCHITECTURE, INC., P.C. 10520 JA REG ' T S DENN " '' LETON A EOFW'S°`NGTON 8-19-2016 7 / 7 7 \ \ \ \ DRAWN BY: CITE A. CunninghamOnVV1LA AUG 2 3 2016 REVIEWED BY: M. (Keifling SCALE: PER NIt0 ENTER AUTHORIZED FOR: PERMIT • / / / \ \ 2" / 2" \ / / \/ \ cy \/ —=- - \...,/ \ . / _ = / - / r „ \ CVy` / II CV 00 ! CV •- TEMPERED GLASS PANEL PAINT FINISH PT 103 / / / / / / TILE BACKSPLASH ACCENT FINISH T 1 04 PAINTED FINISH PT 103 1ST1051 CUP PULL HARDWARE, STAINLESS STEEL FINISH HD 101 CAM LOCK HARDWARE, STAINLESS STEEL FINISH 2-0” 2-0" 4'-2" FIELD VERIFY ELEVATION 1" = 1'-0" AIL STAINED FINISH AT LOWER CABINETS WD101 TOE KICK/ BASE MT101 MW -04 9A SUITE SHOP id8.53 TRIM TO HOLD RESIN IN PLACE - BUTT JOINT FINISH TO BE SMOOTH 6" AT BUSINESS CENTER 4" 4" BUSINESS CENTER 0 CD AT FRONT DESK SOLID WOOD FRAME WITH 1/2" DEEP GROOVE ROUTED OUT TO HOLD DECORATIVE RESIN PANEL AT HOME OFFICE, DECORATIVE 1/2" THICK RESIN PANEL INSET INTO WOOD FRAME. ADD ANYADDI11ONAL SUPPORT AS RECOMMENDED BY MANUFACTURER UNE OF FRAME BELOW PANELS FRONT DESK AND BUSINESS CENTER SCREEN HEIGHT OF EXISTING OPENING 6" 51-8"6" i u y FRC H DESIGN WORLDWIDE 311 Elm Street Suite 600 Cincinnati, OH 45202 www.FRCH.com 513 241 3000 Owner 804.727.1757 Apple Hospitality REIT, Inc. 814 East Main Street Richmond, VA 23219 Chris Zeigler Architect 513.241.3000 FRCH Design Worldwide 1: 513.241.5015 311 Elm Street, Suite 600 Cincinnati, OH 45202-2706 Mike Keifling Interior Design 513.241.3000 FRCH Design Worldwide f: 513.241.5015 311 Elm Street, Suite 600 Cincinnati, OH 45202-2706 Raejean Downs ISSUED INFORMATION OWNER REVIEW SET: BRAND REVIEW SET: 28 APRIL 2016 ISSUED: 19 August 2016 REVISIONS: `Y 4 FRCH 1 ARCHITECTURE, INC., P.C. 10520 JA REG ' T S DENN " '' LETON A EOFW'S°`NGTON 8-19-2016 PROJECT INFORMATION Ce><rl 5 ELEVATION 1/2" = 1'-0" 4'-1" CORNERS TO BE MITERED A 01 WOOD FRAME TO RECEIVE PAINT PT 03 WOOD BASE TO MATCH EXISTING PROFILE - TO RECEIVE PAINT PT 03 BUSINESS CENTER SCREEN PLAN SECTION 3/4" = 1'-0" COUNTERTOP ABOVE v —0- -4" --4"- -P— D1 PLAN SECTION 3/4" = 1'-0" s —®- GENERAL MILLWORK NOTES: a. b. C. d. (0' DRAWINGS PROVIDED INDICATE DESIGN INTENT ONLY - ALL DIMENSIONS MUST BE VERIFIED PRIOR TO PREPARING SHOP DRAWINGS AND/OR ANY FABRICATION MILLWORKER MUST SUBMIT SHOP DRAWINGS OF ALL MILLWORK PRIOR TO FABRICATION REFER TO MATERIAL REFERENCE BINDER FOR ADDITIONAL INFORMATION ALL MILLWORK TO BE PER 'ARCHITECTURAL WOODWORK INSTITUTE' PREMIUM GRADE STANDARD 02 3 g REVIEWED FOR CODE COMPLIANCE APPROVED OCT 2 5 2016 City of Tukwila BUILDING DIVISION I 2 3 4 5 6 7 8 9 10 11 12 13 14 HOMEWOOD SUITES BY HILTON" Seattle/Tukwila, WA Inn Code: SEATK FRC H DESIGN WORLDWIDE 311 Elm Street Suite 600 Cincinnati, OH 45202 www.FRCH.com 513 241 3000 Owner 804.727.1757 Apple Hospitality REIT, Inc. 814 East Main Street Richmond, VA 23219 Chris Zeigler Architect 513.241.3000 FRCH Design Worldwide 1: 513.241.5015 311 Elm Street, Suite 600 Cincinnati, OH 45202-2706 Mike Keifling Interior Design 513.241.3000 FRCH Design Worldwide f: 513.241.5015 311 Elm Street, Suite 600 Cincinnati, OH 45202-2706 Raejean Downs ISSUED INFORMATION OWNER REVIEW SET: BRAND REVIEW SET: 28 APRIL 2016 ISSUED: 19 August 2016 REVISIONS: FRCH 1 ARCHITECTURE, INC., P.C. 10520 JA REG ' T S DENN " '' LETON A EOFW'S°`NGTON 8-19-2016 PROJECT INFORMATION INTERIOR & EXTERIOR RENOVATION Homewood Suites Tukwila 6955 Fort Dent Way Tukwila, WA 98188-2554 PROJECT NUMBER: 032609,000 SHEET INFORMATION Interior Millwork: MW -04 Suite Shop MW -05 Business Center MW -06 Front Desk Screen RECEIVED DRAWN BY: CITE A. CunninghamOnVV1LA AUG 2 3 2016 REVIEWED BY: M. (Keifling SCALE: PER NIt0 ENTER AUTHORIZED FOR: PERMIT 02016 This drawing, printed or otherwise, is the copyrighted property of FRCH Design Worldwide and FRCH/Architecture, Inc., P.C. The drawing may not be used, reproduced or copied without the permission of FRCH Design Worldwide or FRCH/Architecture, Inc., P.0 K J H G F E D C B A L 3 4 5 6 7 8 9 10 11 12 13 14 3'-9" w■■■'■ • ■rr A 1'-6 3/4" 1'-10 3/4" SECTION 1" = 1'-0" AL 1 v 2" GROMMET FOR WIRE MANAGEMENT MW -09 ISLAND MILLWORK • o 1 2 3 Ak r N CV 3'-9" 2" GROMMET FOR WIRE MANAGEMENT ■ rr'a■■r' 1'-6 3/4" 1'-10 3/4" SECTION 1" = 1'-0" DUPLEX OUTLET (EACH SIDE) FOR ABOVE COUNTER APPLIANCES. RUN CORD BEHIND SHELVING AND PLUG INTO POWER IN FLOOR BELOW. GC TO COORDINATE POWER RUN TO FLOOR. REFER TO SHEET id4.11 FOR NEW POWER LOCATION 2" GROMMET FOR CONDUIT MANAGEMENT (COORDINATE WITH ELECTRIC) MW -09 ISLAND MILLWORK 3'-g" �ST(02I PT 103 1 T 13 CV INSTALL (2) NEW DROP-IN HOT CHAFERS IN NEW ISLAND MILLWORK - OWNER PROVIDED - ENSURE PROPER POWER IS PROVIDED ELEVATION 1/2" = 1'-0" 8'-21/2" ST 102 (HD 104 PT) 03 MW -09 ISLAND MILLWORK 13 FRC H DESIGN WORLDWIDE 311 Elm Street Suite 600 Cincinnati, OH 45202 www.FRCH.com 513 241 3000 Il \ uJ /\�` ISSUED INFORMATION OWNER REVIEW SET: BRAND REVIEW SET: 28 APRIL 2016 1: \ l \ 1 I / / \ / / N (\ ; \ / \ / \ / / X N. / / \ N t I \ \ SHEET INFORMATION Interior Millwork: Guest Kitchen Sections & Island Millwork RECEIVED CITY OF TUKWILA AUG 2 3 • - / \ / \ / N / \ / N \ ELEVATION 1/2" = 1'-0" 8'-21/2" ST 102 (HD 104 PT) 03 MW -09 ISLAND MILLWORK 13 1 ST 102 1 1PT103 �--� T 113 04 AIL GENERAL GENERAL MILLWORK NOTES: a. b. C. d. DRAWINGS PROVIDED INDICATE DESIGN INTENT ONLY - ALL DIMENSIONS MUST BE VERIFIED PRIOR TO PREPARING SHOP DRAWINGS AND/OR ANY FABRICATION MILLWORKER MUST SUBMIT SHOP DRAWINGS OF ALL MILLWORK PRIOR TO FABRICATION REFER TO MATERIAL REFERENCE BINDER FOR ADDITIONAL INFORMATION ALL MILLWORK TO BE PER 'ARCHITECTURAL WOODWORK INSTITUTE' PREMIUM GRADE STANDARD O EYNOTES: - -4- -4- -4- -4-- -0— --0— —®- REVIEWED FOR CODE COMPLIANCE APPROVED OCT 2 5 2016 City of Tukwila BUILDING DIVISION 4 5 6 7 8 9 10 11 12 13 14 �-� SUITES BY HILTON'" Seattle/Tukwila, WA Inn Code: SEATK FRC H DESIGN WORLDWIDE 311 Elm Street Suite 600 Cincinnati, OH 45202 www.FRCH.com 513 241 3000 Il \ uJ N ISSUED INFORMATION OWNER REVIEW SET: BRAND REVIEW SET: 28 APRIL 2016 1: \ l \ 1 I FRCH 1 ARCHITECTURE, INC., P.C. ---/\ / / ---/\ / / ---/\ / / N. \ SHEET INFORMATION Interior Millwork: Guest Kitchen Sections & Island Millwork RECEIVED CITY OF TUKWILA AUG 2 3 / AUTHORIZED FOR: PERMIT N / \ / N \ n �\ N / \ / \ / \ / \ / \ / \ / \ / N / \ / 1 ST 102 1 1PT103 �--� T 113 04 AIL GENERAL GENERAL MILLWORK NOTES: a. b. C. d. DRAWINGS PROVIDED INDICATE DESIGN INTENT ONLY - ALL DIMENSIONS MUST BE VERIFIED PRIOR TO PREPARING SHOP DRAWINGS AND/OR ANY FABRICATION MILLWORKER MUST SUBMIT SHOP DRAWINGS OF ALL MILLWORK PRIOR TO FABRICATION REFER TO MATERIAL REFERENCE BINDER FOR ADDITIONAL INFORMATION ALL MILLWORK TO BE PER 'ARCHITECTURAL WOODWORK INSTITUTE' PREMIUM GRADE STANDARD O EYNOTES: - -4- -4- -4- -4-- -0— --0— —®- REVIEWED FOR CODE COMPLIANCE APPROVED OCT 2 5 2016 City of Tukwila BUILDING DIVISION 4 5 6 7 8 9 10 11 12 13 14 �-� SUITES BY HILTON'" Seattle/Tukwila, WA Inn Code: SEATK FRC H DESIGN WORLDWIDE 311 Elm Street Suite 600 Cincinnati, OH 45202 www.FRCH.com 513 241 3000 Owner 804.727.1757 Apple Hospitality REIT, Inc. 814 East Main Street Richmond, VA 23219 Chris Zeigler Architect 513.241.3000 FRCH Design Worldwide f: 513.241.5015 311 Elm Street, Suite 600 Cincinnati, OH 45202-2706 Mike Keifling Interior Design 513.241.3000 FRCH Design Worldwide f: 513.241.5015 311 Elm Street, Suite 600 Cincinnati, OH 45202-2706 Raejean Downs ISSUED INFORMATION OWNER REVIEW SET: BRAND REVIEW SET: 28 APRIL 2016 ISSUED: 19 August 2016 REVISIONS: FRCH 1 ARCHITECTURE, INC., P.C. 10520 REG ?• JA S DENN fl pis 'LETON A EOFW'S NGTON 8-19-2016 PROJECT INFORMATION INTERIOR & EXTERIOR RENOVATION Homewood Suites Tukwila 6955 Fort Dent Way Tukwila, WA 98188-2554 PROJECT NUMBER: 032609.000 SHEET INFORMATION Interior Millwork: Guest Kitchen Sections & Island Millwork RECEIVED CITY OF TUKWILA AUG 2 3 r2,016 DRAWN BY: PEI u nia I1. ER &-61V REVIEWED BY: M. Keifling SCALE: As Noted AUTHORIZED FOR: PERMIT © 2016 This drawing, printed or otherwise, is the copyrighted property of FRCH Design Worldwide and FRCH/Architecture, Inc., P.C. The drawing may not be used, reproduced or copied without the permission of FRCH Design Worldwide or FRCH/Architecture, Inc., P.0 K J H G F E D C B A L 3 4 5 6 7 8 9 10 11 12 13 14 1T1121 0 0 v ••rn.iumIH•fi mmusionumor • muir'I 1°It mm N■■111i 1 ® �� mlimirAI ■ til! _! I • mpg. EXISTING ISTING CENTER OVER 1' VANITY SINK TYP LT -125 �� TYP PF 1 01 ELEVATIONS 1/4" = 1'-0" 1WC1091— 1PT1031 0 1WCI09 ELEVATIONS 1/4" = 1'-0" PLAN 1/4" = 1'-0" ST02 WD ` 01 T 1 12 1 0 0 7, MENS RESTROOMS LODGE CENTER OVER EXISTING VANITY SINK EQ 3'-5" EQ 6'-101/2" `p 3 MR -101 HD -17 PF 1 01 ILYIL T1101 T 1 12 1 WOMENS RESTROOMS LODGE s PUBLIC RESTROOMS LODGE -410- - 4- -4- -!- -4- -r- - 4- - 4- -®- ✓ GENERAL MILLWORK NOTES: a. b. c. d. e. f. 0. DRAWINGS PROVIDED INDICATE DESIGN INTENT ONLY - ALL DIMENSIONS MUST BE VERIFIED PRIOR TO PREPARING SHOP DRAWINGS AND/OR ANY FABRICATION MILLWORKER MUST SUBMIT SHOP DRAWINGS OF ALL MILLWORK PRIOR TO FABRICATION REFER TO MATERIAL REFERENCE BINDER FOR ADDITIONAL INFORMATION ALL MILLWORK TO BE PER 'ARCHITECTURAL WOODWORK INSTITUTE' PREMIUM GRADE STANDARD ALL EQUIPMENT TO BE SUPPLIED BY OWNER THROUGH HILTON. VERIFY DIMENSIONS WITH SHOP DRAWINGS AND FIELD MEASUREMENTS, PRIOR TO ORDERING ALL GRAB BARS TO BE REINSTALLED REFER TO SHEET id0.01 FOR ACCESSIBILITY CLEARANCES FOR ALL FIXTURES AND ACCESSSORIES O KEYNOTES: O O O 0 O O INSTALL TOILET PARTITIONS - VERIFY IN FIELD QUANTITIES AND SIZES MANUFACTURER: BOBRICK DESCRIPTION: SIERRA SERIES 1090 FINISH: DESERT BEIGE SCO2 INSTALL FEMININE WASTE RECEPTACLE INSTALL TWO(2) COAT HOOKS - 60" AFF AND 44"AFF REFER TO INTERIOR SPECIFICATIONS FOR ADDITIONAL REQUIREMENTS HD -07 INSTALL NEW ENTRY DOOR HARDWARE ON INTERIOR SIDE OF DOOR - MATCH EXISTING TYPE WITH SATIN METAL FINISH - INSTALL PRIVACY SET AT MEETING ROOM RESTROOMS ALL EXPOSED PLUMBING MUST BE CHROME PLATED AND WRAPPED VANITY TOP EXTENDED - RELOCATE PLUMBING PER ELEVATION ON THIS SHEET ♦ REVIEWED FOR CODE COMPLIANCE APPROVED OCT 252.016 City of Tukwila BUILDING DIVISION a 1 2 3 4 5 6 7 8 9 10 11 12 13 14 HOMEWOOD .. SUITES BY HILTON Seattle/Tukwila, WA Inn Code: SEATK FRc DESIGN WORLDWIDE 311 Elm Street Suite 600 Cincinnati, OH 45202 www.FRCH.com 513 241 3000 Owner 804.727.1757 Apple Hospitality REIT, Inc. 814 East Main Street Richmond, VA 23219 Chris Zeigler Architect 513.241.3000 FRCH Design Worldwide f: 513.241.5015 311 Elm Street, Suite 600 Cincinnati, OH 45202-2706 Mike Keifling Interior Design 513.241.3000 FRCH Design Worldwide f: 513.241.5015 311 Elm Street, Suite 600 Cincinnati, OH 45202-2706 Raejean Downs ISSUED INFORMATION OWNER REVIEW SET: BRAND REVIEW SET: 28 April 2016 ISSUED: 17June2016 REVISIONS: ...................:............................................................................................................... FRCH 1 ARCHITECTURE, INC., P.C. 10520 REG • 111 � JA S DENN ! `y•LETON A EOFW S'NGTON 8-19-2016 PROJECT INFORMATION INTERIOR & EXTERIOR RENOVATION Homewood Suites Tukwila 6955 Fort Dent Way Tukwila, WA 98188-2554 PROJECT NUMBER: 032609.000 SHEET INFORMATION Elevations: Public Restrooms RECEIVED CITY OF TUKWILA AU6 2 3 2016 DRAWN BY: PER W.Unnc�iFiarITER REVIEWED BY: M. Keifling SCALE: As Noted AUTHORIZED FOR: PERMIT © 2016 This drawing, printed or otherwise, is the copyrighted property of FRCH Design Worldwide and FRCH/Architecture, Inc., P.C. The drawing may not be used, reproduced or copied without the permission of FRCH Design Worldwide or FRCH/Architecture, Inc., P.0 K J H G F E D USER: MKEIFLING L B A 3 4 5 6 7 8 9 10 11 12 13 14 N CV � / / / \ \ \ \ SUITES BY HILTO N' WA SEATK f N, \ \\ > / / / / / x \ N \ \ / / /N BRAND REVIEW SET: 28 April 2016 ISSUED: 19 August 2016 REVISIONS: 1 1'-10 3/4" 1 1'-6 3/4" I I' ELEVATION 1/2" = 1'-0" CV 2'-6" RELOCATED COUNTER MICROWAVE EXISTING ELECTRICAL OUTLETS TO REMAIN. CABINETRY STAINED TO MATCH WD101 MW -08 SHORT WALL MILLWORK 1'-7" ADJUSTABLE SHELF STRAIGHT PULL HARDWARE, STAINLESS STEEL FINISH HD 104 CABINETS STAINED TO MATCH WD101 (T 113 21/2'-1XX�' X SECTION 1" = 1'-0" c CV 2-0" / 1'-0 3/4" • t A / 3/4" / MW -08 BUFFET MILLWORK 34‘- 3/4 OF MIN. HEIGHT 2-6" 1 3/ PAINT UPPER CABINETS PT 103 INSTALL UNDERCABINET LIGHTING ON DEDICATED CIRCUIT, CONCEAL FROM VIEW: CONTECH, LPL1 STANDARD OUTPUT LINEAR LED LIGHTING, 12V; WHITE FINISH, 1" D X LENGTH DETERMINED IN FIELD STRAIGHT PULL HARDWARE STAINLESS STEEL FINISH HD 1 04 M • 21/2"-1 / w 0 0 H C9 LU = VENTILATION FOR COLD PAN STRAIGHT PULL HARDWARE, STAINLESS STEEL FINISH HD 104 CABINETS STAINED TO MATCH WV' 01 VENTILATION FOR COLD PAN 2'-0" I�--2 3/4" T 113 0 CV 0 CV • ELEVATION 1/2" = 1'-O" CV 1'-0 3/4" CV • v 2-11" 2-2 1/8" \ / PAINT UPPER CABINETRY' PT 103 STRAIGHT PULL HARDWARE, STAINLESS STEEL FINISH INSTALL NEW DROP-IN COLD PA WITH STATIONARY SNEEZE GUARD AT NEW MILLWORK - OWNER PROVIDED- ENSURE PROPER POWER IS PROVIDED CD allOral PAINT UPPER CABINETS 2'-6" a 1'-7" ADJUSTABLE SHELF ar PT 103 INSTALL UNDERCABINET LIGHTING ON DEDICATED CIRCUIT, CONCEAL FROM VIEW: CONTECH, LPL1 STANDARD OUTPUT LINEAR LED LIGHTING, 12V; WHITE FINISH, 1" D X LENGTH DETERMINED IN FIELD ILE BACKSPLASH T 104 STRAIGHT PULL HARDWARE, STAINLESS STEEL FINISH HD 104 — CABINETS STAINED TO MATCH WD101 (T 113 2-2 1/2" /--2 3/4" / 8? \ ST 1 02 CABINETRY STAINED TO MATCH MW -07 PERIMETER MILLWORK 1' 0 3/4" • WD101 CV 3'-4" 2-4" • \ / / 3'-0" —EXISTING KEGORATOR TO REMAIN —NEW UNDER COUNTER REFRIGERATOR TUC -27 -LP / F \ \ \ / 11 TT 1 1 TT N. / \I \ / \ ELEVATION 1/2" = 1'-0" PAINT UPPER CABINETS PT 103 STRAIGHT PULL HARDWARE, STAINLESS STEEL FINISH HD 104 INSTALL UNDERCABINET LIGHTING ON DEDICATED CIRCUIT, CONCEAL FRON VIEW: CONTECH, LPL1 2'-6" STANDARD OUTPUT LIN LED LIGHTING, 12V; FINISH, 1" D X LEN DETERMINED IN FIE TILE BACKSPLASH T 104 / 4" 1'-7" ADJUSTABLE SHELF •Z • ■ ■i a ST 102 STRAIGHT PULL HARDWARE, STAINLESS STEEL FINISH HD 104 CABINETS STAINED TO MATCH WD(01 T 1 134D 2-2 1/2" �/--2 3/4" I Alk 1'-2" 3'-10" 1'-10" r -r- L J \N• j 2-4 1/4" CC 0 CCc C7 Lu Y Lc) C\ SECTION PLAN 1/2" = 1'-0" INSTALL (2) NEW DROP -I HOT CHAFERS IN NEW ISLAND MILLWORK - OWNER PROVIDED - ENSURE PROPER POWER IS PROVIDED AT FLOOR AND COORDINATED WITH MILLWORK FABRICATOR AND GC EQ. 1 N 3'-5 1/2" GLASS PANEL UPPER CABINET, INSTALL ACCENT LIGHTING WITHIN DOORS. LIGHTING MUST BE ON DEDICATED SWITCH PAINT UPPER CABINETRY' PT 1 03 EXISTING ELECTRICAL OUTLETS TO REMAIN. ST 02 CABINETRY STAINED TO MATCH MW -07 PERIMETER MILLWORK INSTALL NEW DROP-IN COLD PAN WITH STATIONARY SNEF7F GUARD AT NEW MILLWORK - OWNER PROVIDED - ENSURE PROPER POWER IS PROVIDED EQ. WD101 -1-- -4-- -4- -4-- -4- -.. GENERAL MILLWORK NOTES: a. b. C. d. DRAWINGS PROVIDED INDICATE DESIGN INTENT ONLY - ALL DIMENSIONS MUST BE VERIFIED PRIOR TO PREPARING SHOP DRAWINGS AND/OR ANY FABRICATION MILLWORKER MUST SUBMIT SHOP DRAWINGS OF ALL MILLWORK PRIOR TO FABRICATION REFER TO MATERIAL REFERENCE BINDER FOR ADDITIONAL INFORMATION ALL MILLWORK TO BE PER 'ARCHITECTURAL WOODWORK INSTITUTE' PREMIUM GRADE STANDARD 013 9 REVIEWED FOR CODE COMPLIA,NC APPROVED OCT 252016 City of Tukwila BUILDING DIVISION L 1 2 3 4 5 6 7 8 9 10 11 12 13 14 HOMEWOOD , , Seattle/Tukwila, Inn Code: SUITES BY HILTO N' WA SEATK FRC DESIGN WORLDWIDE 311 Elm Street Suite 600 Cincinnati, OH 45202 www.FRCH.com 513 241 3000 Owner 804.727.1757 Apple Hospitality REIT, Inc. 814 East Main Street Richmond, VA 23219 Chris Zeigler Architect 513.241.3000 FRCH Design Worldwide 1: 513.241.5015 311 Elm Street, Suite 600 Cincinnati, OH 45202-2706 Mike Keifling Interior Design 513.241.3000 FRCH Design Worldwide f: 513.241.5015 311 Elm Street, Suite 600 Cincinnati, OH 45202-2706 Raejean Downs ISSUED INFORMATION c BRAND REVIEW SET: 28 April 2016 ISSUED: 19 August 2016 REVISIONS: 1 1'-10 3/4" 1 1'-6 3/4" I I' i �r IL L 2, 10520 JA S A E -v 1 / CEJ I r w I 1 4I 1 1 DRAWN I :E R M I IA.p F\tig1E R REVIEWED BY: M. Keifling SCALE: As Noted AUTHORIZED FOR: PERMIT s L J 1 o \ w EQ. WD101 -1-- -4-- -4- -4-- -4- -.. GENERAL MILLWORK NOTES: a. b. C. d. DRAWINGS PROVIDED INDICATE DESIGN INTENT ONLY - ALL DIMENSIONS MUST BE VERIFIED PRIOR TO PREPARING SHOP DRAWINGS AND/OR ANY FABRICATION MILLWORKER MUST SUBMIT SHOP DRAWINGS OF ALL MILLWORK PRIOR TO FABRICATION REFER TO MATERIAL REFERENCE BINDER FOR ADDITIONAL INFORMATION ALL MILLWORK TO BE PER 'ARCHITECTURAL WOODWORK INSTITUTE' PREMIUM GRADE STANDARD 013 9 REVIEWED FOR CODE COMPLIA,NC APPROVED OCT 252016 City of Tukwila BUILDING DIVISION L 1 2 3 4 5 6 7 8 9 10 11 12 13 14 HOMEWOOD , , Seattle/Tukwila, Inn Code: SUITES BY HILTO N' WA SEATK FRC DESIGN WORLDWIDE 311 Elm Street Suite 600 Cincinnati, OH 45202 www.FRCH.com 513 241 3000 Owner 804.727.1757 Apple Hospitality REIT, Inc. 814 East Main Street Richmond, VA 23219 Chris Zeigler Architect 513.241.3000 FRCH Design Worldwide 1: 513.241.5015 311 Elm Street, Suite 600 Cincinnati, OH 45202-2706 Mike Keifling Interior Design 513.241.3000 FRCH Design Worldwide f: 513.241.5015 311 Elm Street, Suite 600 Cincinnati, OH 45202-2706 Raejean Downs ISSUED INFORMATION OWNER REVIEW SET: BRAND REVIEW SET: 28 April 2016 ISSUED: 19 August 2016 REVISIONS: FRCH 1 ARCHITECTURE, INC., P.C. 10520 JA S A E REG • 10 DENN •LETON OF S 'i NGTON 8-19-2016 PROJECT INFORMATION INTERIOR & EXTERIOR RENOVATION Homewood Suites Tukwila 6955 Fort Dent Way Tukwila, WA 98188-2554 PROJECT NUMBER: 032609,000 SHEET INFORMATION Pantry Millwork: MW -07 Perimeter MW -08 Shortr�Wall M K- V I L A f:#07 AUG 2�32016 DRAWN I :E R M I IA.p F\tig1E R REVIEWED BY: M. Keifling SCALE: As Noted AUTHORIZED FOR: PERMIT K ► F LAYOUT: a9.00 PLOTTED: 9/19/2016 - 2:17 PM USER: MKEIFLING 10 11 12 13 14 EXISTING EXTERIOR WALL, PATCH AND REPAIR AS NECESSARY PROVIDE METAL STEP FLASHING AT JUNCTION OF ROOF AND EXIST. WALL P.T. 2x LEDGER BOARD SECURED TO EXISTING STRUCTURE WITH HILTI ANCHOR SLEEVES - SECURE RAFTERS TO LEDGER BOARD W/ 'SIMPSON' LSU26 GR 2x6 CEILING JOISTS SPACED 14" o.c. ASPHALT SHINGLES (COLOR AND STYLE TO MATCH EXIST. AS CLOSE AS POSSIBLE WITH AVAILABLE STOCK MATERIAL) ON SYNTHETIC FELT UNDERLAYMENT OVER 3/4" DENS -DECK SHEATHING WITH GAF ICE GUARD AND GUTTER FLASHING 2X6 RAFTERS SPACED AT 1'-4" o.c. - SECURE TO 2x BEAM WITH 'SIMPSON' HURRICANE CLIPS H2.5A (GALV.) 1x6 'AZEK' TRIM BOARD (3 SIDES) PROVIDE ALUMINUM GUTTER/DOWNSPOU TO MATCH EXISTING (ROUTE TO EXISTING) 1/2" DURA -PLY SOFFIT BOARD WITH CONTINUOUS ALUMINUM SOFFIT VENT AND INSECT SCREEN lx 'AZEK' FRIEZE BOARD (3 SIDES) lx 'AZEK' CAP TRIM 2) 2x10 BEAM SECURED TO EACH POST WITH 1/2" 0 GALV. THRU BOLTS TOP AND:.BOIT0M- FASTEN BOARDS TOGETHER WITH 1/2" 0 GALV. THRU BOLTS SPACED AT 1'-0" o.c. TOP STAGGARED TOP AND BOTTOM - LET BEAM INTO POST AS INDICATED PAINTED 5/8" EXTERIOR GRADE GYP. BOARD ON 2x RAFTERS SPACED AT 1'-4" o.c. 6x6 P.T. WOOD POST 'AZEK' COLUMN WRAP 'AZEK' BASE TRIM SECURE POST TO NEW 12" SQ 2,500 PSI POURED CONCRETE FOOTING 3'-6" MIN. DEPTH AND/OR SUITABLE SUBSTRATE W/ 'SIMPSON' STRONG -TIE PPB PORCH POST BASE SECTION 3/4" = 1'-0 .4 _____<=>/e#://#4 v_o" RETURN 2) 2X10 BEAM AND SECURE WITH 'SIMPSON' HANGER HUSC-210-2 SECURED TO 2x10 LEDGER BOARD ATTACHED TO EXISTING STRUCTURE PROVIDE 1) EXTERIOR RATED 6" RECESSED LIGHT FIXTURES CENTERED FRONT TO BACK AND CENTERLINE OF THE CLNG. - TIE TO EXISTING EXTERIOR LIGHT CIRCUIT FROM WALL SCONCE DECORATIVE WALL SCONCE AT EXISTING J -BOX - VERIFY HEIGHT **ALL TRIM PAINTED TO MATCH COLOR OF ACCENT BAND AT EXISTING BUILDING SECONDARY ENTRY atENTRY14H SECONDARY ENTRANCE SECURE 1ST RAFTER AND HEADER TO EXISTING STRUCTURE WITH 1/2"0 THREADED RODS AND HILTI HIT Y70 BOLTS AT 1'-O o.c. STAGGARED PROVIDE SOLID BLOCKING AT INTERIOR FACE OF WALL TO ACCEPT NEW RAFTERS AND BEAMS 0I 4I FRAMING PLAN CANOPY 3/8" = 1'-0" 5E id9.00 6'-7" PHOTO NOT TO SCALE 1 2 s SECONDARY ENTRY at ENTRY 14E AL v NEW LIGHT SCONCE AT EXIST. J -BOX - REFER TO SPECIFICATIONS BUILDING NUMBER SIGNAGE TO BE RELOCATED TO BELOW NEW SCONCE PROVIDE NEW CO 12 1 2' - J, 4 DECORATIVE/UPSCALE TRASH RECEPTACLE ✓j CLE i r%r�,///��4��,,/�4�V4r%%/),,,i/iris%��,, '�r//%%/%/4/ PARTIAL ELEVATION 3/8" = 1'-0" i Eo SECONDARY ENTRANCE OPP CEXISTING CONCRETE I - WALKWAY PATCH AND ) REPAIR AS NECESSARY CANOPY ABOVE PROVIDE WALL SCONCE - (REPLACE EXISTING FIXTURE) J -BOX TO REMAIN LT 101 4" LIGHT GRAY REINFORCED (6x6 W2.9x W2.9 MESH) CONCRETE WITH TOOLED JOINTS AND BROOM FINISH OVER 4" COMPACTED GRAVEL BASE COURSE - DOWEL TO EXISTING SLAB WITH #4 BARS AT 12" o.c. PROVIDE NEW DECORATIVE/UPSCALE TRASH RECEPTACLE (18"0 SHOWN) PARTIAL PLAN 3/8" = 1'-0" PROVIDE 1) WALL SCONCE - REPLACE EXISTING FIXTURE - J -BOX TO REMAIN LT 1 01 PROVIDE NEW DECORATIVE/UPSCALE TRASH RECEPTACLE CANOPY ABOVE 4" LIGHT GRAY REINFORCED (6x6 W2.9x W2.9 MESH) CONCRETE WITH TOOLED JOINTS AND BROOM FINISH OVER 4" COMPACTED GRAVEL BASE COURSE - DOWEL TO EXISTING SLAB WITH #4 BARS AT 12" o.c. NOTE: DIMENSION OF EXISTING WALK WILL DETERMINE REQUIRED WIDTH OF AUGMENTED LANDING - THE INTENT IS TO OBTAIN 18" CLEAR FLOOR SPACE (ACCESIBILITY) + 20" TO ACCOMMODATE THE TRASH RECEPTACLE (BOTH ENTRIES!) SECONDARY ENTRY 1'-6" MIN.CLR. EXISTING CONCRET WALKWAY PATCH Ar'JD REPAIR AS NECESSARY CANOPY PARTIAL PLAN 3/8" =1'-0" SECONDARY ENTRY FINISH LEGEND LT 101 EXTERIOR DECORATIVE WALL SCONCE (2) TOTAL MANUF.: RESTORATION HARDWARE MODEL #: 68050059 BRZ SIZE: LARGE FINISH: BRONZE NOTE= ALL PAINT/COLORS ARE SHERWIN WILLIAMS EXTERIOR GRADE - HWS SCHEME III RECEIVED CITY OF TUKWILA SEP 202016 PERi1AIT CENTER REVIEWED FOR DE COMPLIANCE APPROVED OCT 252016 ,,ity of Tukwila BUILDING DIVISION OVERALL PLAN NOT TO SCALE 5 8 9 10 12 13 14 HOMEWOOD! SITES BY HILTON" Seattle/Tukwila, WA Inn Code: SEATK F RC H DESIGN WORLDWIDE 311 Elm Street Suite 600 Cincinnati, 011 45202 www.FRCH.com 513 241 3000 Owner 804.727.1757 Apple Hospitality REIT, Inc. 814 East Main Street Richmond, VA 23219 Chris Zeigler Architect 513.241.3000 FRCH Design Worldwide f: 513.241.5015 311 EIm Street, Suite 600 Cincinnati, OH 45202-2706 Mike Keifling Interior Design 513.241.3000 FRCH Design Worldwide 1: 513.241.5015 311 EIm Street, Suite 600 Cincinnati, OH 45202-2706 Raejean Downs ISSUED INFORMATION OWNER REVIEW SET: 21 June 2016 BRAND REVIEW SET: 05 July 2016 ISSUED: 19 August 2016 REVISIONS: BLDG. DEPT. COMMENTS 09.19.16 FRCH 1 ARCHITECTURE, INC., P.C. 1p520 n ARc •. 4111/ES DENA,/ STATE DF wA APLETo r• 04./g•23 t* PROJECT INFORMATION INTERIOR & EXTERIOR RENOVATION Homewood Suites Tukwila 6955 Fort Dent Way Tukwila, WA 98188-2554 PROJECT NUMBER: 032609.000 SHEET INFORMATION Exterior Entrance Canopies DRAWN BY: B.Grannan REVIEWED BY: M.Keifling SCALE: As Noted AUTHORIZED FOR: PERMIT id9000 GENERAL NOTES ABBREVIATIONS 10 11 12 13 14 SYMBOLS GENERAL NOTES - MECHANICAL 1. REFERENCE TO RELATED WORK: "REF" INDICATIONS DENOTE WORK COVERED ELSEWHERE (ARCHITECTURAL, STRUCTURAL, CIVIL, ELECTRICAL, LANDSCAPE, OR KITCHEN), OR ITEM BASED ON A SPECIFIC MANUFACTURER'S DIMENSIONS (VERIFY). 2. ELECTRICAL CHARACTERISTICS: REFER TO ELECTRICAL DRAWINGS FOR ELECTRICAL CHARACTERISTICS (VOLTAGES, ETC. OF MECHANICAL EQUIPMENT, UNLESS OTHERWISE INDICATED. 3. CODES: COMPLETE INSTALLATION OF THE MECHANICAL SYSTEM SHALL BE PER THE APPLICABLE BUILDING, MECHANICAL, ENERGY, PLUMBING, FIRE, AND HEALTH CODES AND REGULATIONS AS ADOPTED BY THE LOCAL AHJ. 4. PREPARE AND SUBMIT FOR REVIEW A SHOP DRAWING BASED ON FINAL STRUCTURAL SHOP DRAWINGS FOR LOCATING AND ROUTING ALL DUCTWORK, DAMPERS, EQUIPMENT, PIPING, ETC. A. COORDINATE FLOOR AND BEAM PENETRATIONS WITH STRUCTURAL. B. COORDINATE FINAL LOCATION AND ROUTING WITH CEILING, LIGHTS, WALLS, FIRE SPRINKLER PIPING, AND OTHER TRADES WORK. C. INCLUDE ADDITIONAL OFFSETS, ELBOWS, ROUTING, EQUIVALENT DUCT SIZING EXCHANGE, RELOCATING, ETC. AS REQUIRED FOR A COMPLETE OPERATING MECHANICAL SYSTEM. D. PROVIDE SHOP DRAWINGS AT NO ADDITIONAL COST TO THE OWNER. 5. MECHANICAL CONTRACTOR SHALL LOCATE AND COORDINATE EXACT LOCATION OF ALL MECHANICAL EQUIPMENT WITHIN THE STRUCTURE. 6. ACCESS DOORS: COORDINATE WITH ARCHITECT AND LOCATE ALL ACCESS DOORS ON SHOP DRAWINGS PRIOR TO BEGINNING OF CONSTRUCTION. ACCESS DOORS IN FIRE RATED STRUCTURE SHALL BE FIRE RATED. VERIFY ACCESS DOOR LOCATIONS WITH GENERAL CONTRACTOR PRIOR TO BIDDING. 7. RATED PENETRATION: DUCT PENETRATIONS THROUGH RATED ENCLOSURES SHALL BE FIRE/SMOKE DAMPERED PER THE LATEST EDITION OF THE UNDERWRITERS LABORATORIES(UL) FIRE RESISTANCE WITH HOURLY RATINGS FOR THROUGH -PENETRATION FIRE STOPS SYSTEM VOLUME #2, OR SHALL BE INSTALLED IN STRICT ACCORDANCE WITH THE MANUFACTURER'S UL LISTINGS (3M OR EQUIVALENT). DETERMINE REQUIREMENTS WITH GENERAL CONTRACTOR PRIOR TO BID. 8. EXHAUST OUTLETS: SOURCE -SPECIFIC FANS SHALL BE VENTED TO OUTDOORS WITH A MINIMUM 3' CLEARANCE BETWEEN VENT OUTLETS AND BUILDING OPENINGS, AND 10' MINIMUM BETWEEN VENT OUTLETS AND MECHANICAL AIR INTAKES. 9. ROOF PENETRATIONS: SEE ARCHITECTURAL DRAWINGS FOR ROOF CAP, ROOF CURB, ROOF DRAIN, AND VTR DETAILS. 10. EXPOSED PIPING: PROVIDE CHROME PLATING FOR EXPOSED PIPING IN FINISHED ROOMS. 11. PENETRATIONS: PROVIDE ESCUTCHEON PLATES FOR EXPOSED PIPING PENETRATIONS AND SHEET METAL FLASHING FOR EXPOSED DUCTWORK PENETRATIONS. 12. SHAFT AND PLENUM CONNECTIONS: SEAL CONNECTIONS TO AIR SHAFTS AIRTIGHT. PROVIDE AIRTIGHT SEAL AROUND PENETRATIONS IN AIR PLENUMS. 13. LIGHT FIXTURE CLEARANCE: COORDINATE LOCATIONS OF MECHANICAL WORK TO PROVIDE CLEARANCES OVER LIGHTING FIXTURES FOR REMOVAL AND REPLACEMENT. 14. CABLE TRAYS: DUCTWORK AND PIPING INSTALLED ADJACENT TO ELECTRICAL CABLE TRAYS SHALL ALLOW MINIMUM ACCESS OF 6" ABOVE AND TO THE SIDE OF CABLE TRAYS. 15. MOTORS: COMPLY WITH ENERGY CODE ENFORCED BY AHJ FOR MINIMUM EFFICIENCIES UNDER FULL LOAD. 16. ACCESS CLEARANCES FOR MAINTENANCE AND REPLACEMENT: VERIFY PHYSICAL DIMENSIONS OF EQUIPMENT TO ENSURE THAT ACCESS CLEARANCES CAN BE MET. COORDINATE LOCATIONS OF MECHANICAL WORK AND WORK OF OTHER TRADES TO PROVIDE ACCESS CLEARANCES FOR SERVICE AND MAINTENANCE. COORDINATION REQUIREMENTS 1. PIPING: COORDINATE WITH STRUCTURAL FOR EXACT LOCATION OF ALL STRUCTURAL FRAMING AND FOOTINGS AND FINALIZE THE EXACT ROUTING OF ALL PIPES WITH STRUCTURAL AND AT THE SITE PRIOR AND DURING THE CONSTRUCTION. 2. DUCTWORK: LOCATE AND COORDINATE THE EXACT LOCATION OF DUCTWORK WITH STRUCTURAL PLANS AND WITH THE GENERAL CONTRACTOR PRIOR TO INSTALLATION OF ANY STRUCTURE OR EQUIPMENT. COORDINATE WITH FRAMING CONTRACTOR TO ASSURE JOIST SPACES LINE UP WHEN DUCTWORK MUST PASS THROUGH DIFFERENT JOIST SPACES. 3. ADJUSTMENTS: ALL EQUIPMENT, MOTORS, FANS GAS BURNERS, IGNITION DEVICES, DRIVES, ETC. SHALL BE ADJUSTED AND BALANCED TO OPERATE AT SPECIFIED RATINGS AS REQUIRED FOR THIS PROJECT SITE AND ACCOUNTING FOR ELEVATION ABOVE SEA LEVEL. 4. APPROVALS: MECHANICAL AND PLUMBING EQUIPMENT SHALL BE APPROVED FOR INSTALLATION IN THE PROJECT LOCATION AND SHALL HAVE ALL CERTIFICATIONS AND RATINGS TO MEET ALL ENERGY, POLLUTION, ENVIRONMENTAL, SEISMIC, ETC. CODES AND REGULATIONS. THE CONTRACTOR SHALL COORDINATE WITH HIS MANUFACTURE SUPPLIERS AND SHALL INCLUDE ALL COSTS REQUIRED TO MEET THESE REQUIREMENTS IN HIS BID. 5. FIRE PROTECTION: CONTRACTOR SHALL PROVIDE A FULLY DESIGNED FIRE PROTECTION SPRINKLER SYSTEM IN COMPLIANCE WITH NFPA AND LOCAL CODES. PROVIDE DESIGN, PERMITS, MATERIALS, INSTALLATION, TESTING AND ALL OTHER FOR A FULLY OPERATIONAL SYSTEM. LOCATION OF ALL PIPING TO BE COORDINATED WITH OTHER TRADES. 6. FIREPLACES: COORDINATE WITH THE GENERAL CONTRACTOR TO DETERMINE GAS FIREPLACE FLUE AND COMBUSTION AIR DUCTWORK REQUIREMENTS PRIOR TO BIDDING. PIP 1. ING NOTES DISASSEMBLY PROVISIONS: PROVIDE UNIONS OR FLANGES AT PIPING CONNECTIONS TO EQUIPMENT, COILS, TRAPS, CONTROL VALVES, AND OTHER COMPONENTS TO ALLOW DISASSEMBLY FOR MAINTENANCE. 2. REDUCERS: PROVIDE AS REQUIRED FROM LINE PIPE SIZE TO EQUIPMENT, TRAP, COIL, AND CONTROL VALVE CONNECTION SIZES. 3. OFFSETS: PROVIDE FOR BRANCH LINES TO EQUIPMENT. 4. DIELECTRIC UNIONS: PROVIDE AT CONNECTIONS OF DISSIMILAR PIPE. 5. REFRIGERANT PIPING: PROVIDE SIZING & INSTALLATION IN STRICT ACCORDANCE WITH MANUFACTURER'S INSTRUCTIONS. 6. CONDENSATE DRAIN: PROVIDE A P -TRAP FOR EACH HVAC UNIT CONDENSATE PAN WITH PLUG TEES FOR CLEANING. CONDENSATE DRAINS SHALL BE DISCHARGED TO AN INDIRECT WASTE OR OUTSIDE. INSULATION/LINING NOTES 1. ENERGY CODE: AS A MINIMUM, COMPLY WITH THICKNESSES AND TYPES LISTED IN ENERGY CODE ENFORCED BY AHJ. PLAN NOTES 1. DUCTWORK SHALL BE METALLIC DUCTWORK 2. TEST AND BALANCE WORK SHALL BE PERFORMED BY AN INDEPENDENT TEST AND BALANCE AGENCY. PROVIDE (3) COPIES OF TEST AND BALANCE REPORT TO OWNER. 3. COORDINATE DUCTWORK WITH MISCELLANEOUS OBSTRUCTIONS IN CEILING SPACE. 4. RESTROOM EXHAUST SHALL BE A MINIMUM OF 10' FROM ANY MECHANICAL OUTSIDE AIR INTAKES. 5. ROUTE DUCTWORK UNDERNEATH JOISTS UON. 6. TRANSITION DUCT UNDER BEAMS AND DUCTS. FIELD VERIFY AVAILABLE CEILING CAVITY DIMENSIONS. 7. COORDINATE MOUNTING HEIGHT OF DIFFUSERS WITH ARCHITECTURAL PLANS. SHEET METAL NOTES 1. REFERENCE: SMACNA HVAC DUCT CONSTRUCTION STANDARDS, METAL AND FLEXIBLE, CURRENT EDITION. 2. CLEARANCE: COORDINATE DUCTWORK WITH MISCELLANEOUS OBSTRUCTIONS IN CEILING SPACE. 3. ROUND ELBOWS AND OFFSETS: FULL RADIUS (R/D = 1.5), 5 -PIECE SEGMENTED OR STAMPED. REFER TO SMACNA HVAC FIG 2-7, 3-3. DO NOT USE ANGLED OFFSET (TYPE 1). MITERED OFFSET (TYPE 2) MAY BE USED UP TO 30 DEGREE OFFSET ANGLE. 4. ROUND TEES AND LATERALS: CONICAL TEE PER SMACNA HVAC FIG 3-5; DO NOT USE STRAIGHT TEE; DO NOT USE CONICAL SADDLE TAP FOR EXPOSED DUCTWORK IN FINISHED SPACES. 90 -DEGREE TEE WITH OVAL TO ROUND TAP, LATERAL, AND 45 -DEGREE RECTANGULAR LEAD-IN PER SMACNA HVAC FIG 3-4. 5. RECTANGULAR ELBOWS AND OFFSETS: FULL RADIUS WHERE SPACE PERMITS, R/W = 1.5; OTHERWISE USE SQUARE CORNER ELBOW WITH TURNING VANES. 6. RECTANGULAR DIVIDED FLOW FITTINGS: USE GENERALLY, EXCEPT BRANCHES TO TERMINALS; SMACNA HVAC FIG 2-5, TYPES 1, 2, 4A, AND 4B. DO NOT USE TYPE 3. 7. TURNING VANES: H.E.P. MANUFACTURER OR APPROVED HIGH EFFICIENCY PROFILE AIRFOIL TYPE FOR RECTANGULAR SQUARE THROAT ELBOWS. ACOUSTICAL TYPE FOR RETURN AIR MITERED ELBOWS. 8. TAKEOFFS TO OPENINGS: CONICAL TYPE WITH VOLUME DAMPER FOR ROUND DUCT BRANCHES PER SMACNA HVAC FIG 2-6, MINIMUM INLET DIAMETER 2 INCHES LARGER THAN DUCT SIZE. 45 DEGREE ENTRY FITTING FOR RECTANGULAR DUCT BRANCHES PER SMACNA HVAC FIG 2-6. 9. FLEXIBLE CONNECTIONS: PROVIDE AT EACH DUCT CONNECTION TO FANS, PACKAGED HVAC EQUIPMENT, EXTERNALLY ISOLATED AIR HANDLING UNITS, FAN COIL UNITS, AND SIMILAR EQUIPMENT. EXCEPTION: EQUIPMENT IN CORRIDOR CEILING SPACES WHERE FIRE RATING IS REQUIRED. HVAC NOTES 1. ATTACHMENTS: AIR DISTRIBUTION OUTLETS AND LOUVERS SHALL HAVE ALL REQUIRED ACCESSORIES AND ATTACHMENTS FOR A COMPLETE CONNECTION TO THE SPECIFIC TYPE OF STRUCTURE THAT THEY ARE BEING ATTACHED TO. THIS INCLUDES, BUT IS NOT LIMITED TO, EXTERIOR BRICKS, GWB WALLS, GWB CEILING, ETC. 2. DUCTWORK: DUCTWORK SHALL BE SMOOTH SHEET METAL (CLASS -1). DUCTWORK THROUGH FIRE RATED STRUCTURE AND FLOOR SHALL BE MIN. 26 GA. STEEL. MAXIMUM LENGTH OF FLEXIBLE DUCTS SHALL BE 5'-0", UNLESS OTHERWISE NOTED ON DRAWINGS. DUCTWORK SIZES SHOWN ARE INSIDE CLEAR DIMENSIONS. 3. VOLUME DAMPERS: PROVIDE AN ACCESSIBLE MANUAL VOLUME DAMPER FOR EACH SUPPLY, RETURN, OSA, AND EXHAUST OPENING, LOCATED AS FAR UPSTREAM AS POSSIBLE FROM THE OPENING. PROVIDE A MANUAL VOLUME DAMPER FOR BRANCH MAINS SERVING MORE THAN ONE OPENING. VOLUME DAMPERS IN NON -ACCESSIBLE CEILINGS SHALL HAVE A CONTROL ARM EXTENDED TO AN ACCESSIBLE LOCATION. 4. SEISMIC: PROVIDE SEISMIC RESTRAINTS FOR MECHANICAL EQUIPMENT, PIPING, AND DUCTWORK PER SMACNA AND LOCAL REGULATIONS. 5. FILTER CLEARANCE: PROVIDE ADEQUATE CLEARANCE FOR CHANGING AIR FILTERS. 6. DUCTWORK AND PIPING OUTSIDE OF MECHANICAL ROOMS SHALL BE CONCEALED, COORDINATE WITH THE GENERAL CONTRACTOR TO FUR -OUT AS REQUIRED. 7. FIRE RATINGS: RATED FLOOR/CEILING JOINT SPACES HAVING DUCTWORK INSIDE THEM SHALL BE FIRE/SMOKE PROTECTED TO MAINTAIN THE 1 -HOUR FLOOR/CEILING RATING PER LOCAL JURISDICTIONS. EXHAUST DUCTWORK PENETRATING THE 1 -HOUR ROOF/CEILING OR FLOOR/CEILING ASSEMBLY SHALL HAVE ACCESSIBLE CEILING FIRE DAMPERS. ALTERNATIVELY, THE EXHAUST DUCTWORK SHALL BE ROUTED INSIDE A RATED SHAFT TO PROTECT THE CEILING/ROOF RATING PER THE LOCAL JURISDICTIONS. 8. FIRESTOP: PIPE, DUCT AND CONDUIT PENETRATIONS THROUGH RATED ASSEMBLIES SHALL BE FIRE AND SMOKE STOPPED PER CODE. 9. CORRIDOR THERMOSTAT: PROVIDE TAMPERPROOF THERMOSTATS IN CORRIDORS. DO NOT PROVIDE PLASTIC GUARDS TO MAKE THE THERMOSTATS TAMPERPROOF. PROVIDE BLANK SECURABLE THERMOSTAT COVERS. PRE -CON MEETING NOTES CONTRACTORS SHALL ATTEND A PRE -CONSTRUCTION MEETING WITH THE ENGINEER FOR THE PURPOSE OF REVIEWING THE WORK PRIOR TO ORDERING ANY EQUIPMENT OR PERFORMING ANY WORK. THE MEETING SHALL BE LOCATED AT THE PROJECT SITE ON A DATE AND TIME TO BE MUTUALLY AGREED. THE MEETING WILL BE A WORKING SESSION. THE MEETING WILL BE FACILITATED BY THE ENGINEER AND THE AGENDA WILL INCLUDE A DETAILED REVIEW OF THE PLANS AND SPECIFICATIONS, CROSS CHECK WITH OTHER TRADES FOR COORDINATION ISSUES, REVIEW OF PROPOSED PRODUCTS, REVIEW OF PLANNED MEANS AND METHODS,AND ON-SITE INVESTIGATION OF FIELD CONDITIONS RELATIVE TO EXISTING CONDITIONS THAT COULD AFFECT THE WORK. PERSONS ATTENDING THE MEETING SHALL BE KNOWLEDGEABLE OF THE PROJECT AND SHALL BE THE SPECIFIC PERSONS INTENDED TO CONTINUE WITH THE PROJECT THROUGH TO COMPLETION. IF REQUIRED, REVISED PLANS WILL BE ISSUED THROUGH OFFICIAL CHANNELS. CHANGES IN THE BID PRICE WILL BE DISCUSSED, BUT NO CHANGE ORDERS WILL BE ISSUED UNLESS PROCESSED THOUGH OFFICIAL CHANNELS. IT SHALL BE UNDERSTOOD THAT THE ENGINEER HAS NO AUTHORITY TO ISSUE CHANGE ORDERS. THE FOLLOWING TRADES SHALL BE REPRESENTED FOR THE MINIMUM TIME INDICATED: MECHANICAL SHEET METAL 4 HOURS 4 HOURS 4 HOURS 2 HOURS ALL SESSIONS PLUMBING/PIPING ELECTRICAL SPRINKLER GENERAL CONTRACTOR ACU AIR CONDITIONING UNIT AFF ABOVE FINISHED FLOOR AHJ AUTHORITY HAVING JURISDICTION AHU AIR HANDLING UNIT BDD BACKDRAFT DAMPER BHP BRAKE HORSEPOWER BTUH BRITISH THERMAL UNIT PER HOUR C COMMON CAP CAPACITY CC COOLING COIL CD CEILING DIFFUSER CFM CUBIC FEET PER MINUTE CLG CEILING, COOLING CO CLEANOUT COMB COMBUSTION CONT CONTINUE, CONTROL COP COEFFICIENT OF PERFORMANCE CWS CHILLED/CONDENSER WATER SUPPLY CWR CHILLED/CONDENSER WATER RETURN D DIAMETER. DB DRY BULB, DECIBEL DIM DIMENSION DISCH DISCHARGE DN DOWN EA EXHAUST AIR EAT ENTERING AIR TEMPERATURE EER ENERGY EFFICIENCY RATIO EF EXHAUST FAN EFF EFFICIENCY EG EXHAUST GRILLE ELEC ELECTRIC ESP EXTERNAL STATIC PRESSURE EXH EXHAUST EXT EXTERIOR, EXTERNAL F FAHRENHEIT FCU FAN COIL UNIT FLR FLOOR FPM FEET PER MINUTE FPS FEET PER SECOND FSD FIRE/SMOKE DAMPER G GAS GAL GALLONS GPM GALLONS PER MINUTE GRD GRILLES, REGISTERS, DIFFUSERS GWB GYPSUM WALLBOARD HD HEAD HORIZ HORIZONTAL HP HORSEPOWER HPU HEAT PUMP UNIT HRU HEAT RECOVERY UNIT HVAC HEATING, VENTILATING, AND AIR CONDITIONING HVU HEATING & VENTILATION UNIT HWR HOT WATER RETURN HWS HOT WATER SUPPLY HX HEAT EXCHANGER ID INDIRECT DRAIN, INSIDE DIAMETER IN INCH KW KILOWATT L LONG, LENGTH LB POUND MBH THOUSAND BTU PER HOUR MECH MECHANICAL MCA MIN. CIRCUIT AMPACITY MOCP MAX. OVER CURRENT PROTECTION MTD MOUNTED OSA OUTDOOR AIR OBD OPPOSED BLADE DAMPER OD OUTSIDE DIMENSION OR DIAMETER OPNG OPENING P PUMP PD PRESSURE DROP, PUMPED DRAIN POC POINT OF CONNECTION PRV PRESSURE REDUCING VALVE PSIG POUNDS PER SQUARE IN GAUGE RA RETURN AIR RD ROOF DRAIN REF REFERENCE RF RELIEF FAN RG RETURN GRILLE RPM REVOLUTIONS PER MINUTE SA SUPPLY AIR SCH SCHEDULE SF SUPPLY FAN, SQUARE FOOT SENS SENSIBLE SG SUPPLY GRILLE SMACNA SHEET METAL AND AIR CONDITIONING CONTRACTORS NATIONAL ASSOCIATION SO SCREENED OPENING SP STATIC PRESSURE SS STAINLESS STEEL, SANITARY SEWER SQ SQUARE TG TRANSFER GRILLE TYP TYPICAL UH UNIT HEATER UON UNLESS OTHERWISE NOTED V VENT VENT VENTILATION, VENTILATOR VTR VENT THRU ROOF W WASTE, WATT, WIDE WB WET BULB (TEMPERATURE) 2 DSD EQUIPMENT TYPICAL EQUIPMENT DESIGNATION (EXHAUST FAN SHOWN) DUCT SMOKE DETECTOR ROOM THERMOSTAT OR TEMPERATURE TRANSMITTER O ROOM HUMIDISTAT OR HUMIDITY TRANSMITTER co CARBON MONOXIDE SENSOR so SMOKE DETECTOR TERMINALS CD -12x12 OR 400 CD-1A---DIFFUSER/GRILLE TYPE, AND NUMBER OR SIZE \ 4.00CFM DI FUSNER (FLOW ARROWS JFSD X SHOWN FOR NON SYMMETRICAL AIRFLOW) / / E-A CEILING RETURN/EXHAUST GRILLE � I t 4, 4, UP pUCTWORK 18x12 + DUCT (1ST FIGURE = SIDE SHOWN, 2ND FIGURE = SIDE NOT SHOWN) UP 1/1 DOWN i UP UP O UP CD G MPG 3 RL OL IV LINEAR DIFFUSER, CEILING OR WALL MOUNTED (FLOW ARROWS SHOWN FOR NON SYMMETRICAL AIRFLOW) WALL SUPPLY GRILLE (SG) WALL RETURN/EXHAUST GRILLE (RG, EG) TRANSFER GRILLE (TG), DUCT CONNECTED, WALL MOUNTED W/ OPTIONAL CFM SHOWN TRANSFER GRILLE, CEILING MOUNTED WITH FULL-SIZED LINED DUCT CONNECTION PIPING CONDENSATE DRAINAGE NATURAL GAS - STD. PRESSURE NATURAL GAS - MEDIUM PRESSURE PIPE CAP PIPE PLUG UNION FLANGE GATE VALVE OR BALL VALVE BALL VALVE PRESSURE REDUCING VALVE (PRV) BREAK IN PIPING OR DUCTWORK RAIN LEADER (RL) OVERFLOW RAIN LEADER (OL) CHECK VALVE ffA FSD FD - 8 Y -111114Im_ -- I I I I I I I I I I I Il 111111) 11I11111I11111111111111 I I l I l l l tVi DUCT SECTION, POSITIVE PRESSURE DUCT SECTION, NEGATIVE PRESSURE ROUND DUCT SECTION DUCT PENETRATION THRU FLOOR OR ROOF VOLUME DAMPER FIRE/SMOKE DAMPER (-41 = HORIZ DUCT, -- = VERT DUCT), 2 -HR RATED, UON FIRE DAMPER (--44 = HORIZ DUCT, -- = VERT DUCT), 2 -HR RATED, UON 90' ELBOW, R/D OR R/W=1.5 SQUARE CORNER ELBOW WITH TURNING VANES 90' TAKE -OFF OR TEE 90' CONICAL TAKE -OFF 45' LATERAL TAKE -OFF TRANSITION OR REDUCER (FOT = FLAT ON TOP, FOB = FLAT ON BOTTOM) WYE FITTING 90' RECTANGULAR TAKE -OFF WIN 45' TAPER 90' DIVERGING RECTANGULAR TEE, EITHER RADIUS OR TURNING VANES PARALLEL FLOW BRANCH CONNECTION, EITHER RADIUS OR TURNING VANES FLEXIBLE DUCT ROUND DUCT INDICATOR DRAWINGS ARE DIAGRAMMATIC, SHOWING THE GENERAL LOCATION, TYPE, LAYOUT, AND EQUIPMENT REQUIRED. THE DRAWINGS SHALL NOT BE SCALED FOR EXACT MEASUREMENT. REFER TO ARCHITECTURAL DRAWINGS FOR DIMENSIONS. REFER TO MANUFACTURER'S STANDARD INSTALLATION DRAWINGS FOR EQUIPMENT CONNECTIONS AND INSTALLATION REQUIREMENTS. PROVIDE DUCTWORK, CONNECTIONS, ACCESSORIES, OFFSETS, AND MATERIALS NECESSARY FOR A COMPLETE SYSTEM. DRAWING INDEX HOMEWOOD SUITES BY HILTON" Seattle/Tukwila, WA Inn Code: SEATK DWG DESCRIPTION INCLUDED IN SET 85% REVIEW SET 6/13/16 PERMIT SET 8/22/16 M0.0 LEGEND, GENERAL NOTES, DRAWING INDEX X X ENGINEERING, INC 19401 40TH AVE W, SUITE 302 LYNNWOOD, WA 98036 206-364-3343 TEL / 425-835-0098 FAX PROJECT INFORMATION INTERIOR & EXTERIOR RENOVATION Homewood Suites Tukwila 6955 Fort Dent Way Tukwila, WA 98188-2554 PROJECT NUMBER: 032609.000 M0.1 PROJECT NOTES, TABLES, & CALCULATIONS X X 0 0 M0.2 MECHANICAL SCHEDULES X X M1.0 LEVEL 1 MECHANICAL PLAN X X M2.0 MTG ROOM- BLDG 1 LEVEL 2 MECHANICAL PLAN X X M4.0 DETAILS X X 10 11 12 SEPARATE PERMIT AND APPROVAL REQUIRED 13 14 311 Elm Street Suite 600 Cincinnati, OH 45202 www.FRCH.com 513 241 3000 Owner 804.727.1757 Apple Hospitality REIT, Inc. 814 East Main Street Richmond, VA 23219 Chris Zeigler Architect 513.241.3000 FRCH Design Worldwide 1: 513.241.5015 311 Elm Street, Suite 600 Cincinnati, OH 45202-2706 Mike Keifling Interior Design 513.241.3000 FRCH Design Worldwide f: 513.241.5015 311 Elm Street, Suite 600 Cincinnati, OH 45202-2706 Raejean Downs ISSUED INFORMATION OWNER REVIEW SET: BRAND REVIEW SET: ISSUED: 07.29.2016 REVISIONS: Dooaoa000 Oo O• • pF;ii4i ••.. P % 8 _. . 14 fi ...._ , 0o , f .%RoBIsoN ENGINEERING, INC 19401 40TH AVE W, SUITE 302 LYNNWOOD, WA 98036 206-364-3343 TEL / 425-835-0098 FAX PROJECT INFORMATION INTERIOR & EXTERIOR RENOVATION Homewood Suites Tukwila 6955 Fort Dent Way Tukwila, WA 98188-2554 PROJECT NUMBER: 032609.000 SHEET INFORMATION LEGENDi GENERAL NOTE% & '.�:._ EIVED ORAWN BY: BK, SITY OF TU K1/�/IL SCALE: VARIES PERMIT CENTERRA!R REVIEWED BY: RR AUG 2 3 2016 AUTHORIZED FOR: PERMIT REVIEW 0 0 J F E D C B A 10 11 12 13 14 OUTSIDE AIR CALCULATIONS REFRIGERANT PIPE NSULATION OUTSIDE AIR SCHEDULE ROOM AREA PEOPLE CFM/SQFT CFM/PERSON OSA CFM (AREA) (AREA) OSA CFM (PEOPLE) TOTAL CF CFM CONFERENCE ROOM 734 50 0.06 5 44 250 294 NOTES: 1. CALCULATION PER TABLE 403.3 PER WA STATE AMENDMENTS TO 2012 IMC PIPE INSULATION SCHEDULE SERVICE MATERIAL THICKNESS FIELD APPLIED JACKET VAPOR RETARDER REQUIRED FINISH NOTES REFRIGERANT SECTION, LIQUID AND HOT -GAS PIPING (WHERE REQUIRED). FLEXIBLE1" ELASTOMERIC MINERAL -FIBER BLANKET NONE NO NONE COPPER PIPING. OPERATING TEMPERATURE 35 TO 50 DEG F. ABOVE GROUND INSULATION OUTSIDE THE BUILDING FLEXIBLETWO ELASTOMERIC 1/2"NONE MINERAL -FIBER BLANKET YES COATS OF MANUFACTURER'S RECOMMENDED UV INHIBITOR COPPER PIPING. OPERATING TEMPERATURE 35 TO 50 DEG F. NOTES: INSULATION SHALL BE PER SEATTLE ENGERY CODE SECTION C403.2.8 DUCT INSULATION SCHEDULES WA STATE ENERGY CODE DUCT INSULATION SCHEDULE SERVICE MATERIAL R -VALUE (MIN. INSTALLED) VAPOR RETARDER REQUIRED SUPPLY & RETURN AIR DUCTS IN UNCONDITIONED SPACE MINERAL -FIBER BLANKET 6.0 NO SUPPLY & RETURN AIR DUCTS CONCEALED WITHIN CONDITIONED SPACE MINERAL -FIBER BLANKET N/A N/A OUTSIDE AIR DUCTS MINERAL -FIBER BLANKET 7.0 YES OUTSIDE AIR DUCTS IN UNCONDITIONED SPACE MINERAL -FIBER BLANKET 4.5 N/A OUTSIDE AIR FROM EXTERIOR OF BUILDING TO AUTOMATIC SHUT-OFF DAMPER AND LESS THAN 2,800 CFM MINERAL -FIBER BLANKET 7.0 YES OUTSIDE AIR FROM EXTERIOR OF BUILDING TO AUTOMATIC SHUT-OFF DAMPER AND GREATER THAN 2,800 CFM MINERAL -FIBER BLANKET NOTE 2 YES ROUND & RECTANGULAR EXHAUST AIR DUCTS IN UNCONDITIONED SPACE MINERAL -FIBER BLANKET N/A N/A ROUND & RECTANGULAR SUPPLY AIR DUCTS, EXPOSED WITHIN CONDITIONED SPACE MINERAL -FIBER BLANKET N/A N/A ROUND & RECTANGULAR RETURN AIR DUCTS, EXPOSED WITHIN CONDITIONED SPACE MINERAL -FIBER BLANKET N/A N/A NOTES (1) INSULATION SHALL BE PER WASHINGTON ENGERY CODE SECTION C403.2.7.2 (2) DUCT SHALL MEET THE REQUIREMENTS OF METAL FRAMED WALLS PER TABLE C402.1.2 APPLICABLE CODES APPLICABLE CODES APPLICABLE CODES 2012 INTERNATIONAL BUILDING CODE (IBC) 2012 INTERNATIONAL MECHANICAL CODE (IMC) 2012 UNIFORM PLUMBING CODE (UPC) 2012 WASHINGTON STATE ENERGY CODE (WSEC) WA STATE ENERGY CODE 1. HVAC THERMOSTATS SHALL BE SET TO MAINTAIN A MINIMUM DEADBAND OF 5F IN AREAS SERVED AS REQUIRED PER WSEC C403.2.4.2. 2. PER WSEC 403.2.7, ALL DUCTS SHALL BE INSULATED AS FOLLOWS: A. OUTSIDE AIR DUCTS SERVING INDIVIDUAL SUPPLY AIR UNITS WITH LESS THAN 2800 CFM SUPPLY AIR CAPACITY: R-7. B. UNHEATED EQUIPMENT ROOMS WITH COMBUSTION AIR LOUVERS, ISOLATED FROM CONDITIONED SPACE AT SIDES, TOP AND BOTTOM: R-11. C. SUPPLY & RETURN DUCTS WITHIN UNCONDITIONED SPACE: R-6. D. SUPPLY & RETURN DUCTS LOCATED OUTSIDE THE BUILDING: R-8. E. SUPPLY WITH SA TEMP <55F OR >105F WITHIN CONDITIONED SPACE: R-3.3. 3. MOTORIZED DAMPERS: PER WSEC C402.4.5.2 PROVIDE MOTORIZED DAMPERS ON ALL OUTSIDE AIR INTAKES, EXHAUST OUTLETS AND RELIEF OUTLETS SERVING CONDITIONED SPACES WHICH CLOSE AUTOMATICALLY WHEN THE SYSTEM IS OFF. RETURN AIR DAMPERS SHALL BE EQUIPPED WITH MOTORIZED DAMPERS. SEE WSEC C402.4.5.2 FOR EXCEPTIONS AND ADDITIONAL REQUIREMENTS. 4. PER WSEC C402.4.5.1 MOTORIZED DAMPERS FOR ELEVATOR AND STAIR SHAFTS, PROVIDE DAMPERS THAT ARE POWERED CLOSED AND FAIL OPEN IN THE RELAXED POSITION. (ELEVATOR AND STAIR SHAFT DAMPERS SHALL BE TIED TO THE FIRE ALARM SYSTEM). bt 0)39 SEPARATE PERMIT AND A=PPROVAL REQUIRED 10 11 12 13 14 .. SUITES BY HILTON' Seattle/Tukwila, WA Inn Code: SEATK FRC DESIGN WORLDWIDE 311 Elm Street Suite 600 Cincinnati, OH 45202 www.FRCH.com 513 241 3000 Owner 804.727.1757 Apple Hospitality REIT, Inc. 814 East Main Street Richmond, VA 23219 Chris Zeigler Architect 513.241.3000 FRCH Design Worldwide t: 513.241.5015 311 Elm Street, Suite 600 Cincinnati, OH 45202-2706 Mike Keisling Interior Design 513.241.3000 FRCH Design Worldwide 1: 513.241.5015 311 Elm Street, Suite 600 Cincinnati, OH 45202-2706 Raejean Downs ISSUED INFORMATION OWNER REVIEW SET: BRAND REVIEW SET: ISSUED: 07.29.2016 REVISIONS: GoDD❑000 O 40,.,-R0e°o 0'AmysZQ'..0 0 4Zajzo 0•.i_iQ❑O , kfi. moo°Ort oa❑novo ROBISON ENGINEERING, INC 1 940 1 40TH AVE W, SUITE 302 LYNNWOOD, WA 98036 206-364-3343 TEL / 425-835-0098 FAX PROJECT INFORMATION INTERIOR & EXTERIOR RENOVATION Homewood Suites Tukwila 6955 Fort Dent Way Tukwila, WA 98188-2554 PROJECT NUMBER: 032609.000 SHEET INFORMATION TABLE,PROJECT NOTES, CALCULAPI MS CITY CF TUKWILI DRAWN BY: BK, AS AUG 2 3 2016 REVIEWED BY: RR PERMIT CENTER SCALE: VARIES AUTHORIZED FOR: PERMIT REVIEW 10 11 12 13 14 HEAT PUMP SCHEDULE - OUTDOOR UNIT EQUIP NO. SERVICE MOUNTING/ DISCHARGE 2 STAGE COOLING HEATING ELECTRICAL REFRIDGERANT DIMENSIONS, INCHES BASIS OF DESIGN DIMENSIONS, INCHES EQUIP BASIS OF DESIGN (1)(2)(3) CAPACITY, WEIGHT, MIN. OSA, CFM (4) CONNECTED ' STAGE 1 MOCP LIQUID HIGH TEMP. LOW TEMP. W H AHU-1 CONFERENCE ROOM HORIZONTAL DUCTED 2005 294 57.0 52.5 33.2 NO. SERVICE TONS COOLING STAGE 2 COOLING SEER/EER HEATING HEATING COP VOLTAGE MCA MOCP CHARGE, LIQUID GAS L W H LBS (1)(2)(3)(4) FAN COIL UNIT SCHEDULE RECEIVED rtt DRAWN BY: BKSSTY OF T U K W I L A CAPACITY, MBH CAPACITY, MBH AUTHORIZED FOR: PERMIT REVIEW CAPACITY, BTUH CAPACITY, BTUH LBS HP -1 CONFERENCE ROOM 5 42.5 60.0 15.50/11.50 52.5 33.2 3.28 208V/3P 23.9 40 11.4 3/fi" 3/4" 30" 39Y2" 39" 331 LENNOX SPB060H4 AHU-1 NOTES: (1) ARI LISTED WITH ALL STANDARD FEATURES, INSTALLATION ACCESSORIES AND COMPRESSOR SHORT CYCLING PROTECTION. FILTER DRIVER, REFRIGERANT LINE FILTER, LIQUID SOLENOID VALVE, AND SAFETY PRESSURE SWITCHES. INSTALL REFRIGERANT TUBING AND LENGTH IN STRICT ACCORDANCE WITH MANUFACTURER'S RECOMMENDATION. (2) PROVIDE ALL REQUIRED ACCESSORIES FOR LOW—AMBIENT AND LONG—LINE APPLICATIONS. (3) ROUTING OF REFRIGERANT LINES FROM INDOOR TO OUTDOOR UNITS NOT SHOWN ON PLANS. CONTRACTOR TO FIELD COORDINATE ROUTING. (4) REFRIGERANT SHALL BE R -410A. AIR HANDLING UNIT SCHEDULE - INDOOR UNIT EQUIP NO. SERVICE MOUNTING/ DISCHARGE FANELECTRICAL TOTAL COOLING CAPACITY, MBH HIGH TEMP. HEATING CAPACITY, BTUH LOW TEMP. HEATING CAPACITY, BTUH (2) ELECTRICAL HEATING CAPACITY, BTUH PIPING CONNECTIONS,IN DIMENSIONS, INCHES WEIGHT (LBS) BASIS OF DESIGN (1)(2)(3) CONNECTED OUTDOOR UNIT AIRFLOW, CFM MIN. OSA, CFM (4) VOLTAGE MCA MOCP LIQUID GAS L W H AHU-1 CONFERENCE ROOM HORIZONTAL DUCTED 2005 294 57.0 52.5 33.2 20.5 208V/3P 32 40 % 3/4 58}x" 24" 21Y4" 212 LENNOX CBX32MV-60 HP -1 NOTES: (1) REFRIGERANT SHALL BE R -410A. (2) PROVIDE 8KW ELECTRIC HEAT ECB29-8 (28K33). (3) PROVIDE HORIZONTAL SUPPORT FRAME. (4) PROVIDE SINGLE POINT ELECTRICAL CONNECTION (5) PROVIDE PROGRAMMABLE THERMOSTAT AND 100% MODULATING ECONOMIZER CONTROLLER. (6) SEE VENTILATION CALCULATIONS ON SHEET MO -1 FOR MINIMUM OSA CFM. ECONOMIZER SCHEDULE EQUIP NO. SERVICE MOUNTING/ DISCHARGE DAMPER ELECTRICAL DIMENSIONS, INCHES WEIGHT (LBS) BASIS OF DESIGN (1) CONNECTED INDOOR UNIT AIRFLOW, CFM IN. W.G. VOLTAGE L W H ECON-1 CONFERENCE ROOM DUCTED 2000 .15 24V 2374" 202" 247 " 83.8 LENNOX EMD14-65 AHU-1 NOTES: (1) SEE VENTILATION CALCULATIONS ON SHEET MO -1 FOR MINIMUM OSA CFM. (2) PROVIDE POWER WIRING HARNESS. DIFFUSER SCHEDULE MARK NECK SIZE TYPE MOUNTING TYPE MAX CFM MAXIMUM N.C. MANUFACTURER MODEL CD -1 14X14 SUPPLY SURFACE 817 30 TITUS MCD—AA RG -1 20X20 RETURN SURFACE 1799 30 TITUS 350 EG -1 10X10 EXHAUST SURFACE 413 30 TITUS 350 INLINE EXHAUST FAN EQUIP NO. SERVICE MOUNTING/ DISCHARGE DUCT SIZE, DIA FAN ELECTRICAL DIMENSION WEIGHT BASIS OF DESIGN MAX AIRFLOW, CFM RPM VOLTAGE MCA MOCP DIAMETER HEIGHT EF -1 STORAGE ROOM INLINE DUCT 10" 417 2509 120V/1P 1.11 15 13Y4" 9Y4" 12 FANTECH FR250 NOTES: (1) PROVIDE BACKDRAFT DAMPER. (2) 10 b(b.0)L3 9 SEPARATE PERMIT AND APPROVAL REQUIRED 11 12 13 14 HOMEWOOD SITES BY HILTON" Seattle/Tukwila, WA Inn Code: SEATK FRC DESIGN WORLDWIDE 311 Elm Street Suite 600 Cincinnati, OH 45202 www.FRCH.com 513 241 3000 Owner 804.727.1757 Apple Hospitality REIT, Inc. 814 East Main Street Richmond, VA 23219 Chris Zeigler Architect 513.241.3000 FRCH Design Worldwide 1: 513.241.5015 311 Elm Street, Suite 600 Cincinnati, OH 45202-2706 Mike Keisling Interior Design 513.24t3000 FRCH Design Worldwide 1: 513.241.5015 311 Elm Street, Suite 600 Cincinnati, OH 45202-2706 Raejean Downs ISSUED INFORMATION OWNER REVIEW SET: BRAND REVIEW SET: ISSUED: 07.29.2016 REVISIONS: 000/00000 40 , ,. R.O�°00 8Z—h.: 4'64 si:Z-V1 15 0..(> �. :mss. 0 6 - 1 0 •%;L 40000,29, 00❑00t30 ROBISON ENGINEERING, INC 19401 40TH AVE W, SUITE 302 LYNNWOOD, WA 98036 206-364-3343 TEL / 425-835-0098 FAX PROJECT INFORMATION INTERIOR & EXTERIOR RENOVATION Homewood Suites Tukwila 6955 Fort Dent Way Tukwila, WA 98188-2554 PROJECT NUMBER: 032609.000 SHEET INFORMATION MECHANICAL SCHEDULE RECEIVED rtt DRAWN BY: BKSSTY OF T U K W I L A REVIEWED BY: RR AUG 2 3 2016 SCALE: VARIES PERMIT CENTER AUTHORIZED FOR: PERMIT REVIEW 10 11 12 13 14 O 0 0 o rn cgo COD vuwi, (E) CD NEW RETURN CONNECT 10 UNIT AS (E.) GRILL SAME CD. IE) CD (E)RG RG -2 (E) Co NEW RETURN GRILL CONNECT TO SAME UNIT AS (E) CD. a RG— E CD NEW RETURN GRILL CONNECT TO SAME UNIT AS (E) CD. LEILD LELQ (E)RG 1' EXISTING 30MBH SYSTEM ADEQUATE. EXISTING DUCTWORK TO REMAIN. —1 cJ r MFr.HaNic ai MAIN BUILDING LEVEL 1 SCALE: 1' = 1'-0" SEPARATE PERMIT AND APPROVAL REQUIRED HOMEWOOD SUITES BY HILTON' Seattle/Tukwila, WA Inn Code: SEATK FRC DESIGN WORLDWIDE 311 Elm Street Suite 600 Cincinnati, OH 45202 www.FRCH.com 513 241 3000 Owner 804.727.1757 Apple Hospitality REIT, Inc. 814 East Main Street Richmond, VA 23219 Chris Zeigler Architect 513.241.3000 FRCH Design Worldwide f: 513.241.5015 311 Elm Street, Suite 600 Cincinnati, OH 45202-2706 Mike Keifling Interior Design 513.241.3000 FRCH Design Worldwide f: 513.241.5015 311 Elm Street, Suite 600 Cincinnati, OH 45202-2706 Raejean Downs ISSUED INFORMATION OWNER REVIEW SET: BRAND REVIEW SET: ISSUED: 07.29.2016 REVISIONS: 0,oaa0000 0i ''-..Rpei°o 8Z .vla 13 o c•� JI . 0 ' •.: -., 6 00000 /QNAL eVo000 �29�1 oo❑❑❑oo I ENGINEERING, INC 19401 40TH AVE w, SUITE 302 LYNNwOOD, WA98036 206-364-3343 TEL / 425-835-0098 FAX PROJECT INFORMATION INTERIOR & EXTERIOR RENOVATION Homewood Suites Tukwila 6955 Fort Dent Way Tukwila, WA 98188-2554 PROJECT NUMBER: 032609.000 SHEET INFORMATION MAIN BUILDING LEVEL 1 MECHANICAL CiIY OF I UKWII DRAWN BY: BK, AS AUG 2 3 2016 REVIEWED BY: RR SCALE: VARIES PERMIT CENTEI AUTHORIZED FOR: PERMIT REVIEW 10 11 12 13 14 HP 1 MOUNTED PER DETAIL 2/M4-0 (E)HP 10' CLEARANCE FROM EXHAUST TO OUTSIDE AIR INLET ROUTE CONDENSATE DRAIN TO LANDSCAPING P 18"X18" DAMPE SEE D 18"X18" OUTSIDE AIR DUCT TO ROOF. SEE DETAIL 1/M-40 ROUTE REFRIGERANT LINE TO HP -1. ROUTE CONDENSATE TO LANDSCAPE. ACCESSIBLE ATTIC SPACE BAROMETRIC RELIEF TO ROOF. TAIL 1/M4-0 (E)HP (DEMO)CD FCON— EXHAUST CT TO ROOF. SEE DETAIL 1/M4-0 (DEMO)RG TO AHU-1 -S .-AGE ROOM ATTIC ACCESS DOOR 10' CLEAR EXHAUST AIR IN FROM OUTSIDE LEVEL 3 ATTIC ABOVE MEETING ROOM FLAG NOTES: REMOVE EXISTING DIFFUSERS TO CONFERENCE ROOM. CAP DUCTS IN WALL. EXISTING HEAT PUMP TO REMAIN. CONTRACTOR SHALL PROVIDE MOTORIZED DAMPERS ON OUTSIDE AIR DUCTS THAT OPEN FULLY WHEN FAN COIL RUNS. INTERLOCK WITH FAN COIL UNIT. PROVIDE INTERNALLY LINED EXHAUST DUCT AND RETURN DUCTS WITH 1" LINER TO REDUCE NOISE. PROVIDE AN INTERNALLY LINED BOX WITH 1" LINER ON DIFFUSERS. FIELD COORDINATE DIFFUSER LOCATION Th EXISTING LIGHTING. LEVEL 3 MEETING ROOK SCALE: 1/4" = BLDG. 1 Q2-9) LEVEL 2 MEETING ROOM BLDG. 1 SCALE: 1/4" = V -O" 12) bIlr 030 SEPARATE PERMIT AND APPROVAL REQUIRED 10 11 12 13 14 HOMEWOOD ...... SUITES ( BY HILTON Seattle/Tukwila, WA Inn Code: SEATK FRCH DESIGN WORLDWIDE 311 Elm Street Sub 600 Cincinnati, OH 45202 www.FRCH.com 513 241 3000 Owner 804.727.1757 Apple Hospitality REIT, Inc. 814 East Main Street Richmond, VA 23219 Chris Zeigler Archltect 513.241.3000 FRCH Design Worldwide f: 513,241.5015 311 Elm Street, Suite 600 Cincinnati, OH 45202-2706 Mike Keifling Interior Design 513.24t3000 FRCH Design Worldwide f: 513.241.5015 311 Elm Street, Suite 600 Cincinnati, OH 45202-2706 Raejean Downs ISSUED INFORMATION OWNER REVIEW SET: BRAND REVIEW SET: ISSUED: 07.29.2016 REVISIONS: opt31:11300p, IN - 30.64),00 2,7 • .. 44WAS:;/,'' —41 0 6 ta 4, , 0 to. -. : '- .."-% , .• .......... • , „1/4. (1,0.--, % /MAL 410\0 Til -4'tj OC7cmot30- ROBISON ENGINEERING, INC 19401 40TH AvE W, SUITE 302 LYNNWOOD, WA 98036 206-364-3343 TEL / 425-835-0098 FAx PROJECT INFORMATION INTERIOR & EXTERIOR RENOVATION Homewood Suites Tukwila 6955 Fort Dent Way Tukwila, WA 98188-2554 PROJECT NUMBER: 032609.000 SHEET INFORMATION MEETING ROOMBLDG 1 LEVEL 2 MECHANICAL PLAER/ED Ci OF TUKWILA DRAWN BY: BK, AS AUG 2 3 2016 REVIEWED BY: RR SCALE: VARItbEERMIT CENTER AUTHORIZED FOR: PERMIT REVIEW 20 10 11 12 13 14 #10 SM SCREW TWO PER BRACKET 3/8" CONCRETE WEDGE ANCHORS WITH 2" EMBEDMENT, TWO PER SIDE (MIN) 3"X3"X1/8" ANGLE (MIN) TWO PER SIDE CONCRETE PAD, 6" WIDER THAN EQUIPMENT ON ALL SIDES, 4" THICK (MIN) UNIT NEOPRENE SUPPORT PAD AT EACH STRUCTURAL SUPPORT CONTACT (MIN ONE PER CORNER) CONDENSING UNIT, CONCRETE PAD MOUNTED BIRDSCREEN -- ROOFING AND FLASHING INSTALLED PER MANUFACTURES REQUIREMENTS DUCT PENETRATION THROUGH ROOF DUCT SIZED PER PLANS 10 11 12 13 0)39 SEPARATE PERMIT AND APPROVAL REQUIRED 14 HOMEWOOD ., SUITES BY HILTON" Seattle/Tukwila, WA Inn Code: SEATK FRC DESIGN WORLDWIDE 311 Elm Street Suite 600 Cincinnati, OH 45202 www.FRCH.com 513 241 3000 Owner 804.7271757 Apple Hospitality REIT, Inc. 814 East Main Street Richmond, VA 23219 Chris Zeigler Architect 513.241.3000 FRCH Design Worldwide f: 513.241.5015 311 Elm Street, Suite 600 Cincinnati, OH 45202-2706 Mike Keisling Interior Design 513.241.3000 FRCH Design Worldwide f: 513.241.5015 311 Elm Street, Suite 600 Cincinnati, OH 45202-2706 Raejean Downs ISSUED INFORMATION OWNER REVIEW SET: BRAND REVIEW SET: ISSUED: 07.29.2016 REVISIONS: o .o°�`� Roe°oo F �s \ o o 0 o j _ o • �� P� 6 00: �........ O_ Xnati POW 4360 ll ROBISON ENGINEERING, INC 19401 40TH AVE w, SUITE 302 LYNNwooD, WA 98036 206-364-3343 TEL / 425-835-0098 FAx PROJECT INFORMATION INTERIOR & EXTERIOR RENOVATION Homewood Suites Tukwila 6955 Fort Dent Way Tukwila, WA 98188-2554 PROJECT NUMBER: 032609.000 SHEET INFORMATION DETAILS RECEIVED CAT OF TUKWILI DRAWN BY: BK, AS AUG 2 3 2016 REVIEWED BY: RR PERMIT CENTER SCALE: VARIES AUTHORIZED FOR: PERMIT REVIEW K J H G F D C B A L P 5 6 7 8 9 10 11 12 13 14 GENERAL NOTES 1. REFER TO ARCHITECTURAL REFLECTED CEILING PLANS FOR THE EXACT LOCATION OF ALL CEILING MOUNTED DEVICES. 2. REFER TO ARCHITECTURAL INTERIOR ELEVATION DRAWINGS, WHERE THE ARCHITECT HAS DRAWN SUCH ELEVATIONS, FOR THE LOCATIONS OF ALL WALL MOUNTED DEVICES. 3. ALL WORK SHALL BE DONE IN ACCORDANCE WITH THE 2014 NATIONAL ELECTRIC CODE AND ALL STATE AUTHORITIES HAVING JURISDICTION. 4. MINIMUM CONDUCTOR SIZE: ALL CIRCUIT HOMERUNS AND ALL CONDUIT -AND-WIRE CIRCUITS SHALL BE #12 AWG UNLESS OTHERWISE NOTED ON THE DRAWINGS OR IN THE SPECIFICATIONS. 5. MINIMUM SIZE CONDUIT SHALL BE 1/2" DIAMETER. INSTALL A MINIMUM OF THREE 1/2" EMPTY SPARE CONDUITS FROM EACH RECESSED PANELBOARD TO THE CEILING SPACE ABOVE. 6. ALL CONDUIT PENETRATIONS THROUGH THE ROOF TO SERVE MECHANICAL EQUIPMENT SHALL BE WITHIN THE ASSOCIATED EQUIPMENT ROOF CURB. COORDINATE LOCATIONS OF PENETRATIONS WITH THE MECHANICAL CONTRACTOR. 7. PROVIDE ACCESS DOORS IN WALLS AND CEILINGS WHERE ACCESS TO CONCEALED ELECTRICAL BOXES AND DEVICES IS REQUIRED. 8. FROM EACH VOICE/DATA OUTLET BOX, STUB 1" C. TO CEILING SPACE FOR VOICE/DATA CABLES. TERMINATE CONDUIT WITH END BUSHING, UNLESS SHOWN OTHERWISE. 9. CONDUIT, LIGHT FIXTURES, AND OTHER COMPONENTS MAY BE SHOWN LARGER THAN ACTUAL SIZE. CONDUIT ROUTING IS SHOWN WITH AN EXAGGERATED SPACING FOR CLARITY. ELECTRICAL CONTRACTOR SHALL COORDINATE WITH ALL CONTRACTORS TO ENSURE CONDUIT PLACEMENT DOES NOT CONFLICT WITH LOCATION SENSITIVE COMPONENTS SUCH AS LIGHT FIXTURES. 10. INTEGRATED EQUIPMENT RATINGS SHOWN ARE MINIMUMS. CONTRACTOR SHALL PROVIDE MANUFACTURER'S EQUAL OR NEXT HIGHER STANDARD RATINGS. 11. ALL PULL CORD/WIRE PROVIDED FOR EMPTY RACEWAY/CONDUIT SYSTEMS SHALL HAVE A MINIMUM STRENGTH OF 200 LBS TENSILE STRENGTH. ALL EMPTY CONDUITS SHALL HAVE A PULL CORD. 12. THE ELECTRICAL CONTRACTOR SHALL OBTAIN ALL PERMITS AND PAY SUCH FEES AS MAY BE NECESSARY FOR INSPECTIONS, TESTS, AND OTHER SERVICES NECESSARY FOR THE COMPLETION OF THEIR WORK. 13. COORDINATE DEVICE WALL PLATE SECTION WITH ARCHITECT PRIOR TO PURCHASING. MATCH NEW WITH EXISTING DEVICE WALL PLATES WHERE PRACTICABLE. 14. ALL LAY -IN LIGHTING FIXTURES SHALL BE CONNECTED TO A BRANCH CIRCUIT JUNCTION BOX WITH A FLEXIBLE FIXTURE TAIL. A MAXIMUM OF FOUR FIXTURE TAILS SHALL BE CONNECTED TO A SINGLE JUNCTION BOX. FIXTURE TO FIXTURE WIRING OF LAY -IN LIGHTING FIXTURES IS NOT PERMITTED, EXCEPT WHERE MASTER/SLAVE FIXTURE PAIRS ARE INDICATED OR SPECIFIED. 15. THERE SHALL BE NO SPLICES OF WIRING INSIDE PANELBOARDS OR DISCONNECT SWITCHES. ONLY ONE WIRE SHALL BE TERMINATED TO ANY SINGLE LUG ON A CIRCUIT BREAKER. 16. ALL WIRING AND CONDUIT SIZES SHALL BE BASED ON THE REQUIREMENTS OF THE 2014 NATIONAL ELECTRICAL CODE. 17. UNLESS OTHERWISE NOTED, FOR LIGHTING AND RECEPTACLE HOMERUNS HAVING A TOTAL LENGTH OF 100' TO 200', USE #10 CONDUCTORS; FOR HOMERUNS HAVING A TOTAL LENGTH OF 200' OR GREATER, USE #8 CONDUCTORS. 18. COORDINATE THE REQUIREMENTS FOR OVERCURRENT PROTECTIVE DEVICE SIZE, DISCONNECT SWITCH SIZE, AND CONDUCTOR AND CONDUIT SIZES WITH THE REQUIREMENTS OF THE MECHANICAL EQUIPMENT THAT IS ACTUALLY TO BE INSTALLED AND PROVIDE AND INSTALL ALL ELECTRICAL COMPONENTS AS REQUIRED. THE ELECTRICAL COMPONENT SIZING SHOWN ON THESE DRAWINGS IS BASED UPON THE REQUIREMENTS FOR THE SPECIFIED MECHANICAL EQUIPMENT AVAILABLE AT THE TIME OF DESIGN. VARIATIONS IN REQUIREMENTS MAY OCCUR AS A RESULT OF THE PROVISION OF OTHER MANUFACTURER'S EQUIPMENT OR IN CHANGES TO THE SPECIFIED EQUIPMENT. SUCH REVISED REQUIREMENTS ARE A PART OF THIS CONTRACT AND SHALL BE ACCOMMODATED WITHOUT ADDITIONAL CHARGE. 19. FOR COORDINATION PURPOSES, LIGHTING FIXTURES AND DEVICES MAY BE MOVED A MAXIMUM DISTANCE OF FIVE FEET, PRIOR TO INSTALLATION, AT NO COST TO THE OWNER, UPON INSTRUCTION BY THE ARCHITECT OR ENGINEER. 20, COORDINATE THE EXACT LOCATION OF ALL THERMOSTATS, STARTERS, DISCONNECTS, ETC. AND COORDINATE ALL REQUIREMENTS FOR CONTROL AND POWER WIRING WITH THE MECHANICAL CONTRACTOR, EMS CONTRACTOR, OR THE TRADE PROVIDING THE EQUIPMENT. 21. WHERE RECEPTACLES ARE SHOWN BACK-TO-BACK ON A COMMON WALL, OFFSET THE TWO BOXES AT LEAST SIX INCHES. 22. PROVIDE LUGS AS REQUIRED FOR ALL ELECTRICAL EQUIPMENT TO ACCEPT THE SIZE AND NUMBER OF CONDUCTORS SHOWN IN THESE DOCUMENTS. 23. PROVIDE THE TYPE OF MOUNTING HARDWARE AND TRIM NECESSARY FOR THE PROPER INSTALLATION OF SPECIFIED LIGHTING FIXTURES IN THE TYPE OF CEILING WHERE INSTALLED. EXTERIOR CONDUIT RUNS MINIMUM 24" BELOW FINISHED GRADE. 24. 25. ALL CONDUCTORS SHALL BE THWN/THHN UNLESS OTHERWISE INDICATED. TERMINATIONS SHALL BE RATED FOR 75 DEGREES C MINIMUM. DEVIATIONS SHALL COMPLY WITH NEC ARTICLE 110-14(c) FOR EXACT EQUIPMENT BEING PROVIDED. 26. COORDINATE AND PAY FOR ALL REQUIREMENTS FOR POWER WITH THE LOCAL POWER COMPANY AND ALL REQUIREMENTS FOR TELEPHONE SERVICE AND TO CREATE PATHWAY WITH THE LOCAL TELEPHONE COMPANY. 29. COORDINATE EXACT LOCATION OF ALL LIGHTING FIXTURES IN ELECTRICAL/MECHANICAL SPACES WITH EQUIPMENT, DUCTWORK AND PIPING. 30. IT IS THE INTENT OF THESE DRAWINGS AND OTHER RELATED DOCUMENTS TO PRODUCE A COMPLETE AND FUNCTIONING ELECTRICAL SYSTEM. THE ELECTRICAL CONTRACTOR SHALL PROVIDE ALL LABOR, MATERIAL AND OTHER SERVICES AS MAY BE NECESSARY TO ACHIEVE THIS PRODUCT. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO BRING TO THE ATTENTION OF THE ARCHITECT ANY DISCREPANCIES IN THE PLANS AND SPECIFICATIONS THAT WILL AFFECT THE WORK, PRIOR TO SUBMISSION OF HIS BID PRICE. 31. THE CONTRACTOR SHALL GUARANTEE ALL HIS WORK AND MATERIALS FOR A PERIOD OF ONE YEAR AFTER ACCEPTANCE BY OWNER. 32. PANELBOARD DIRECTORIES SHALL BE UPDATED TO REFLECT ALL WORK DONE AS PART OF THIS PROJECT. PROVIDE TYPED PANEL SCHEDULES UPON COMPLETION. 33. PAINTED FIRE RETARDANT PLYWOOD BACKBOARDS AS INDICATED ON THE DRAWING ARE. TO BE FURNISHED AND INSTALLED BY THE GENERAL CONTRACTOR. 34. CONTRACTOR TO REMOVE ALL UNUSED EXISTING EQUIPMENT, CONDUIT, J -BOXES AND CONDUCTORS. MAKE SAFE. o � ELECTRICAL LEGEN D RECEPTACLES 11) 41) 8 GFCI Q GFCI Qj +42" I(il MISCELLANEOUS QT SIGNAL/COMMUNICATION v a POWER WP 4 MAU-1,5HP,480,3 ® EF-1,12KVA,208,1 SWITCHES $a OS AL DT $T $2 v � AB3EVIATIO\S v o � SINGLE RECEPTACLE DUPLEX RECEPTACLE: WALL MOUNTED, +18" AFF CONTROLLED AND NON CONTROLLED DUPLEX RECEPTACLE (SPLIT WIRED RECEPTACLE) DUPLEX RECEPTACLE - ABOVE COUNTER DUPLEX GFCI ABOVE COUNTER DUPLEX GFCI DUPLEX RECEPTACLE, WITH HEIGHT ABOVE FINISHED FLOOR INDICATED CEILING MOUNTED DUPLEX RECEPTACLE DOUBLE DUPLEX RECEPTACLE: WALL MOUNTED, +18" AFF FLOOR BOX ONE DUPLEX RECEPTACLE QUAD RECEPTACLE FLOOR BOX FLOOR BOX ONE DUPLEX RECEPTACLE + ONE DATA FLOOR BOX ONE DUPLEX RECEPTACLE + ONE DATA + ONE VOICE SPECIAL PURPOSE RECEPTACLE, AS NOTED JUNCTION BOX: 4SQ MOUNTED JUNCTION BOX: 4SQ WALL MOUNTED JUNCTION BOX: 4SQ TRACK CONNECTION FOR LIGHTED MIRROR COORDINATE LOCATION AND ELEVATION WITH ARCHITECT PRIOR TO ROUGH -IN THERMOSTAT DATA OUTLET: WALL MOUNTED CSD +18" AFF U.O.N. TELEPHONE OUTLET: WALL MOUNTED ® +18" AFF U.O.N. TELEVISION OUTLET: WALL MOUNTED ® +18" AFF U.O.N. COMBINED TELEPHONE/DATA OUTLET: WALL MOUNTED ® +18" AFF U.O.N. PANELBOARD NON-FUSED DISCONNECT SWITCH (WP = NEMA 3R WHERE APPROPRIATE ) FUSED DISCONNECT SWITCH MOTOR CONNECTION (EQUIPMENT NAME, HORSEPOWER, VOLTAGE, AND PHASE INDICATED) EQUIPMENT CONNECTION (EQUIPMENT NAME, LOAD, VOLTAGE, AND PHASE INDICATED) TRANSFORMER, DRY TYPE, SHOWN TO SCALE SWITCH, SINGLE POLE; WITH SWITCHING SUBSCRIPT OCCUPANCY SENSOR SWITCH, PROXIMITY INFRARED SWITCH, SINGLE POLE; WALLBOX DIMMER SWITCH, SINGLE POLE; WITH PILOT LIGHT CEILING MOUNTED OCCUPANCY SENSOR CEILING MOUNTED OCCUPANCY SENSOR CEILING MOUNTED AMBIENT LIGHT SENSOR WALL MOUNTED DUAL TECHNOLOGY OCCUPANT SENSOR SWITCH, TIMER. SWITCH, TWO POLE. DETAIL IDENTIFICATION SYMBO NAME FLAG NOTE LIGHTING �L10 >) REVISION NOTE REVISION DEFINITION, AREA ENCIRCLED CONTAINS DRAWING CHANGES MADE SUBSEQUENT TO PREVIOUS ISSUE FIXTURE IDENTIFICATION SYMBOL (TYPE A, (2) 32 WATT LAMPS SHOWN) SEE SCHEDULE SEE LUMINAIRE SCHEDULE FOR FIXTURE SYMBOLS SWITCH, SPST, 20A, 120/277V CEILING MOUNTED DAYLIGHT HARVESTING SENSOR -SENSOR SWITCH CEILING MOUNTED SENSOR WITH OCCUPANCY CONTROL ALONG WITH DIMMING CAPABILITY FOR DAYLIGHT HARVESTING. SENSOR -SENSOR CEILING MOUNTED OCCUPANCY SENSOR SWITCH AIL A ACT AFF AFG AIC AWG BKR C CCTV CH CKT CLG CU DC DIS DPDT EMS EMT EWC FA FACP FLA FT. G GA. GFI GND GRS H HID HOA HP HVAC HZ IG IMC IN. J -BOX kcmil AMPS ABOVE COUNTERTOP ABOVE FINISHED FLOOR ABOVE FINISHED GRADE AMPERE INTERRUPTING CURRENT AMERICAN WIRE GAUGE BREAKER CONDUIT CLOSED CIRCUIT TELEVISION COUNTER HEIGHT CIRCUIT CEILING COPPER, CONDENSING UNIT DIRECT CURRENT DISCONNECT DOUBLE -POLE, DOUBLE -THROW ENERGY MANAGEMENT SYSTEM ELECTRICAL METALLIC TUBING ELECTRIC WATER COOLER FIRE ALARM FIRE ALARM CONTROL PANEL FULL LOAD AMPS FOOT, FEET GROUND GAUGE GROUND FAULT CIRCUIT INTERRUPTER GROUND GALVANIZED RIGID STEEL HEIGHT HIGH INTENSITY DISCHARGE HAND -OFF -AUTOMATIC HORSEPOWER HEATING, VENTILATING AND AIR CONDITIONING HERTZ ISOLATED GROUND INTERMEDIATE METAL CONDUIT INCH, INCHES JUNCTION BOX 1000 CIRCULAR MILS A. kV kVA kVAR kW kWH LB LRA LTG MCA MCB MH MLO N/A NEC NEMA NFPA NO. N/O,N/C OSHA PF PH PROVIDE PVC RLA SPDT SPST TYP UL U.O.N. V VA VAC WP WT XFMR KILOVOLT KILOVOLT -AMPS KILOVOLT -AMPS REACTIVE KILOWATT KILOWATT-HOUR LENGTH POUNDS LOCKED ROTOR AMPS LIGHTING MINIMUM CIRCUIT AMPACITY MAIN CIRCUIT BREAKER METAL HALIDE MAIN LUGS ONLY NOT APPLICABLE NATIONAL ELECTRICAL CODE NATIONAL ELECTRICAL MANUFACTURER'S ASSOCIATION NATIONAL FIRE PROTECTION ASSOCIATION NUMBER NORMALLY OPEN, NORMALLY CLOSED ON CENTER OCCUPATIONAL SAFETY AND HEALTH ADMINISTRATION POWER FACTOR PHASE FURNISH AND INSTALL POLYVINYL CHLORIDE RUNNING LOAD AMPS SINGLE POLE DOUBLE THROW SINGLE POLE SINGLE THROW TYPICAL UNDERWRITERS LABORATORIES, INC. UNLESS OTHERWISE NOTED VOLT VOLT-AMPERE VOLTS ALTERNATING CURRENT WATT, WIDTH WEATHERPROOF WATERTIGHT, WEIGHT TRANSFORMER bUcrO23� DRAWING INDEX DRAWING NO DESCRIPTION E0-0 LEGEND, GENERAL NOTES, DRAWING INDEX E1-0 MAIN BUILDING LEVEL 1 LIGHTING E1-1 LIGHTING COMPLIANCE ENERGY FORMS E2-0 MAIN BUILDING LEVEL 1 POWER E2-1 BUILDING 1- LEVEL 2 POWER E3-0 PANEL/LUMINAIRE SCHEDULE & FUNCTIONAL TEST A. O A. 1 2 3 4 5 6 7 8 9 10 11 12 13 14 HOMEWOOD SITES BY HILTON" Seattle/Tukwila, WA Inn Code: SEATK FRC H DESIGN WORLDWIDE 311 Elm Street Suite 600 Cincinnati, OH 45202 www.FRCH.com 513 241 3000 Owner 804.727.1757 Apple Hospitality REIT, Inc. 814 East Main Street Richmond, VA 23219 Chris Zeigler Architect 513.241.3000 FRCH Design Worldwide f: 513.241.5015 311 Elm Street, Suite 600 Cincinnati, OH 45202-2706 Mike Keifling Interior Design 513.241.3000 FRCH Design Worldwide 1: 513.241.5015 311 Elm Street, Suite 600 Cincinnati, OH 45202-2706 Raejean Downs ISSUED INFORMATION OWNER REVIEW SET: BRAND REVIEW SET: ISSUED: 07.29.2016 REVISIONS: ppt:100001:7 o`t % Z ❑ o J _ o •o •; •.: i. ...... -.' ° X16 „„ oi" �onop RoBIsoN ENGINEERING, INC 19401 40TH AVE W, SUITE 302 LYNNWOOD, WA 98036 206-364-3343 TEL / 425-835-0098 FAX PROJECT INFORMATION INTERIOR & EXTERIOR RENOVATION Homewood Suites Tukwila 6955 Fort DentWay Tukwila, WA 98188-2554 PROJECT NUMBER: 032609.000 SHEET INFORMATION 1 LEGEND,' NOTES, & DRAWING INDEX HE(.;EIVE`., DRAWN BY: B _q�� �'-nY OF TUKWILA REVIEWED BY: RR AUG 2 3 2016 SCALE: VARIES JER1VlIT CENTER AUTHORIZED FOR: PERMIT REVIEW 02016 This drawing, printed or otherwise, is the copyrighted property of FRCH Design Worldwide and FRCH/Architecture, Inc., P.C. The drawing may not be used, reproduced or copied without the permission of FRCH Design Worldwide or FRCH/Architecture, Inc., P.0 K J H G F E D C B A 10 11 12 13 14 NOT IN SCOPE NOT IN SCOPE LT -102 LT -102 CEILING FAN CEILING FAN 0 a LT -102 d LT -104 LT -102 LT -102 LT -1020-L LT -1020-[ EXISTING CIRCUIT CEILING FAN 11 LT -119 CEILING FAN CONTROL LEGEND $ TOGGLE SWITCH FOR MANUAL ON/OFF LIGHTING CONTROL. X,y $ TOGGLE SWITCH FOR MANUAL ON/OFF LIGHTING CONTROL FOR MULTIPLE CONTROL GROUPS. ID DIMMER SWITCH FOR MANUAL MULTI—LEVEL LIGHTING CONTROL. SWITCH SHALL ALSO HAVE MANUAL ON/OFF FUNCTIONALITY. 08 09 $ 1I) SWITCHES LABELED 'OS' SHALL BE CAPABLE OF TURNING OFF ALL CONNECTED LUMINAIRES WITHIN 30 MINUTES OF SPACE BEING VACANT. g. PS PHOTOSENSOR FOR DAYLIGHT ZONE CONTROL SHALL BE CAPABLE OF AUTOMATICALLY ADJUSTING THE LIGHTING LEVEL OF ALL CONNECTED LUMINAIRES BASED ON THE DAYLIGHT LEVEL IN THE SPACE. OS OCCUPANCY SENSORS SHALL BE CAPABLE OF TURNING OFF ALL CONNECTED LUMINAIRES WITHIN 15 MINUTES OF SPACE BEING VACANT. SWITCHBANK abcdef 4►U11WW3$ +96" GFCI 36 EXISTING CIRCUIT LT -102 LT -126 LT -126 LT -126 LT -102 LT -102 LT -126 LT -126 LT -126 LT -126 ..T-126 LT -101E LT -101 (TYP.) LT -125 a1 LT -101 '1' LT -107 LT -101 LT -125 LIGHTING PLAN -LEVEL 1 SCALE: 3/16" = 1'—O" AL WASHINGTON ENERGY CODE LIGHTING NOTES LIGHTING 1. SUPPORT LIGHT FIXTURES FROM BUILDING STRUCTURE. DO NOT SUPPORT FIXTURES FROM SUSPENDED CEILING. 2. PROVIDE LIGHT FIXTURES WITH PROPER FITTING FLANGES, MOUNTING SUPPORTS, AND ACCESSORY ITEMS, UL LISTED FOR CONDITIONS OF USE. 3. THE MAXIMUM LIGHTING POWER THAT MAY BE CONTROLLED FROM A SINGLE SWITCH OR AUTOMATIC CONTROL SHALL NOT EXCEED EIGHTY PERCENT OF A TWENTY AMPERE CIRCUIT LOADED. A MASTER CONTROL MAY BE INSTALLED PROVIDED THE INDIVIDUAL SWITCHES RETAIN THEIR CAPABILITY TO FUNCTION INDEPENDENTLY. 4. CIRCUIT BREAKERS MAY NOT BE USED AS THE SOLE MEANS OF SWITCHING. 5. EXIT SIGNS SHALL HAVE AN INPUT POWER DEMAND OF 5 WATTS OR LESS. OCCUPANCY SENSOR SPECIFICATIONS 1. OCCUPANCY SENSORS SHALL BE CAPABLE OF AUTOMATICALLY TURNING OFF ALL THE LIGHTS IN AN AREA NO MORE THAN 30 MINUTES AFTER THE AREA IS VACATED. 2. LIGHT FIXTURE CONTROLLED BY OCCUPANCY SENSORS SHALL HAVE A WALL—MOUNTED, MANUAL SWITCH CAPABLE OF TURING OFF LIGHTS WHEN SPACE IS OCCUPIED. 3. WALL—MOUNTED OCCUPANCY SENSOR SHALL BE MANUAL "ON". EXCEPTIONS: SEE SEATTLE ENERGY CODE 1513.8.1. LIGHTING CONTROL COMMISSIONING 1. OCCUPANCY SENSORS, PHOTOCELLS, CONTRACTORS AND OTHER LIGHTING CONTROLS SHALL BE TESTED TO ENSURE THAT CONTROL DEVICES, COMPONENTS, EQUIPMENT AND SYSTEMS ARE CALIBRATED, ADJUSTED AND OPERATE IN ACCORDANCE WITH APPROVED PLANS, SPECIFICATIONS, AND ALL SUB—SECTION OF SEATTLE CODE 1513.8. 2. SUBMIT A REPORT OF TEST PROCEDURES AND RESULTS TO THE OWNER. FLAGGED NOTES SWITCHED GFCI RECEPTACLE FOR STRING LIGHTING. EXISTING TO REMAIN. ELECTRICAL CONTRACTOR TO VERIFY AND USE EXISTING LIGHTING CIRCUITS WHEN POSSIBLE. SWITCHBANK RELOCATED SURFACE MOUNTED FLUORESCENT. tUrOi3� SEPARATE PERMIT AND APPROVAL REQUIRED 2 3 4 5 6 7 8 9 10 11 12 13 14 HOMEWOOD SUITES .' W BY HILTON" Seattle/Tukwila, WA Inn Code: SEATK FRC DESIGN WORLDWIDE 311 Elm Street Suite 600 Cincinnati, OH 45202 www.FRCH.com 513 241 3000 Owner 804.727.1757 Apple Hospitality REIT, Inc. 814 East Main Street Richmond, VA 23219 Chris Zeigler Architect 513.241.3000 FRCH Design Worldwide f: 513.241.5015 311 Elm Street, Suite 600 Cincinnati, OH 45202-2706 Mike Keisling Interior Design 513.241.3000 FRCH Design Worldwide f: 513.241.5015 311 Elm Street, Suite 600 Cincinnati, OH 45202-2706 Raejean Downs ISSUED INFORMATION OWNER REVIEW SET: BRAND REVIEW SET: ISSUED: 07.29.2016 REVISIONS: �ooaaoo0 .o° IN. ..Oe000 0 0v/. ' O o 8 Z •42. V 4. i IS 0 Jim /.:. 0 - 1 0000�; ` 0000-1 DOant3O� RoBIsoN ENGINEERING, INC 1 940 1 40TH AVE W, SUITE 302 LYNNWOOD, WA 98036 206.364 3343 TEL / 425-835-0098 FAX PROJECT INFORMATION INTERIOR & EXTERIOR RENOVATION Homewood Suites Tukwila 6955 Fort Dent Way Tukwila, WA 98188-2554 PROJECT NUMBER: 032609.000 SHEET INFORMATION MAIN BUILDING LEVEL 1 LIGHTING/ED t;I i V OF TUKWIL DRAWN BY: BK, AS AUG 2 3 2016 REVIEWED BY: RR SCALE: VARIES PERMIT CENTEF AUTHORIZED FOR: PERMIT REVIEW © 2016 This drawing 0 n d 8 CC u_ U CCU - 8 8 Q U co .13 U LL 2 U u_ IIA 8 .22 4.3 0 0 .a 0 K J H G F E D C B A L 8 9 10 12 b(vol3 SEPARATE PERMIT AND APPROVAL REQUIRED 10 11 12 13 14 HOMEWOOD SUITES BY HILTON" Seattle/Tukwila, WA Inn Code: SEATK FRC DESIGN WORLDWIDE 311 Elm Street Suite 600 Cincinnati, OH 45202 www.FRCH.com 513 241 3000 ce=B -S ace . °Me+ th .,. L. TG INT -SPACE Interior Li hti• n , S ace -By -Space ISSUED INFORMATION k,LG .T. , S�.S, U,, L., ia.2g.h.tt"tn..n.xummary confi�t.. „ 2015 Washington State Energy Code Compliance Forms for Commercial Buildings including R2, R3, R4 over 3 stories and all R1 Revised July M .,,.., 2016 Lighttng ..., SummaCGT -SUM 2015 Washington State Energy Code Compliance Forms for Commercial Buildings including R2, R3, R4 oer 3 stories and all R1 Revised July 2016 2015 Washington State Energy Code Compliance Forms for Commercial Buildings including R2, R3, R4 over 3 stories and all R1 Revised July 2016 Project Title: HOMEWOOD SUITES-TUKWILA, WA Date 8/22/2016 Project Title: HOMEWOOD SUITES-TUKWILA, WA Date 8/22/2016 PROJECT INFORMATION INTERIOR & EXTERIOR RENOVATION Homewood Suites Tukwila 6955 Fort Dent Way Tukwila, WA 98188-2554 Project Info Project Title: HOMEWOOD SUITES-TUKWILA, WA Date 8/22/2016 DRAWN BY: BK, AS �'I1 �'' 01- l UKv' AUG 2 3 20 REVIEWED BY: RR SCALE: VARIES PERMIT CEN1 AUTHORIZED FOR: PERMIT REVIEW Calculation Area NOTE' Q Q Addition- Q Addition stand alone + existing g Spaces where < 50% of a Spaces where >_ 50% of Q luminaires are replaced Q luminaires are replaced Q For Building Department Use Interior Lighting System g g y Description p Compliance forms do not Applicant Information. Provide contact information for individual who can respond to inquiries about compliance form information provided. For Building Department Use require a password to Company Name: ROBISON ENGINEERING INC. use. Instructional and Company Address: 19401 40TH AVE. WEST, SUITE 302, LYNNWOOD, WA 98031 LPA Calculation Type Q Standard 0 Additional Efficiency Package Option Q C406.3 Reduced Interior Lighting Power To comply with C406.3, the Proposed LPD shall be 25% lower than the Target LPA. Refer to C406.3 for additional requirements. calculating cells are write - Applicant Name: BOLYNNA KONG protected. Applicant Phone: 206-364-3343 Applicant Email: BKONG@ROBISONENGINEERING.COM Interior Lighting Power Allowance Method ❑ Building Area Method Select method used in project. ✓ Space -by -space Method Project Description p ❑ New Building ❑ Addition Include PROJ-SUM form (included in envelope forms workbook) 4 Alteration ❑ Plans Included with lighting complliance forms. Maximum Allowed NOTE 1 Lighting Wattage Location (plan #, room #) Space Type Ceiling Height NOTE 2 Gross Interior Area in ft2 Allowed Watts per ft2 Watts Allowed (watts/ft2 x area) Interior Lighting Controls ❑ All C405.2.1 - C405.2.8 Controls ❑ C405.2 Exception 5 Luminaire Level Lighting Control (CLEC) Additional EfficiencyPackage Option ❑ 9 P C406.4 Enhanced digital lighting controls To comply with C406.4, no less than 90% of the total installed interior lighting power shall comply with the required controls per C406.4. Building Additions Refer to Section C502.2.6 for Compliance Method I _ Interior lighting Lighting systems in addition area comply with all applicable provisions as a stand alone new construction project ❑ 1 1 Exterior lighting ❑ Dining area: Bar/lounge/leisure dining 247 0.8 60 212 Lobby: hotel 2205 0.850 187 4 Office: Enclosed 4 55 0.8 90 405 additional requirements. Lighting systems in addition are combined with existing building lighting systems to demonstrate compliance ❑ ❑ Restroom: all other 589 0.780 459 Gymnasium/fitness center: Exercise area 407 0.580 236 Dwelling Unit Interior Lighting g gFor Permanently installed interior lighting fixtures in dwelling units comply with: Q 0 C405.2 thru C405.5 Commercial Lighting Controls and LPA Q 0406.3 High Efficacy Lighting 0 Addition Is combined with existing: g: For interior lighting projects, include new + existing interior lighting fixture wattage in Wattage table In LTG4NT--BLD or LTG -INT -SPACE form. exterior lighting projects, include new + existing exterior lighting fixture wattage Tradable and Proposed Non -Tradable Lighting Wattage tables in LTG -EXT form. Proposed Lighting in Proposed Storage room 241 0.500 121 Corridor: air other 167 0.530 8 9 Conference/meeting/multipurpose 733 0.980 718 Interior and Exterior Lighting Power Interior lighting Parking garage Exterior lighting Total Area 5044 Lighting Alterations Select all Lighting Power and Lighting Control elements that apply to the scope of the retrofit project. If project includes a combination of spaces where less than 50% of the existing fixtures are replaced 50% or more of existing are replaced Less than 50% of existing are replaced Lamp and/or ballast replacement only — existing total wattage not increased - ❑ ./ ❑ ❑ ❑ ❑ ❑ ______ ❑ Exterior Lighting System Description Retail Display Allowance from LTG -INT -DISPLAY NOTE 8 Lobby Art/Exhibit Display Allowance from LTG -INT -DISPLAY Allowed Watts 4115 Proposed Lighting Wattage "u t s p g g ga in some spaces, and 50% or more of the fixtures are replaced In others, then provide separate lighting power compliance forms for the two retrofit p conditions. Spaces undergoing the same type of retrofit may be combined into one lighting power compliance form. Refer to Section 0503.6 for additional 50% or more replaced - Total lighting power of new LPA per Sections C405.4.2 and C405.5.2. include Lighting Wattage table in LTG -INT BLD, LTG -INT Less than 50% replaced - Total lighting ower of p g g p total lighting power prior to alteration. Include new Wattage table in LTG -INT -BLD, LTG-iNT-SPACE 50% threshold applies to number of luminaires for installed wattage for exterior luminaires. -SPACE new + or interior + existing -to -remain fixtures sl all comply with total new +existing -to -remain fixtures in Proposed or LTG -EXT form.. + existing -to -remain fixtures shall not exceed the g- existing -to -remain fixtures in the Proposed Lighting LTG -EXT form. spaces and parking garages, and total Location (plan #, (P) room # p NOTE 4, 5, 6 Fixture Description Number of Fixtures Watts/ NOTE 7 Fixture , Watts Proposed P LT-101/LT-101 E: 6" LED RECESSED DOWNLIGHT 12 19 228 LT -102: INCANDESCENT WALL SCONCE 14 12 168 LT -104: 18" INCANDESCENT DRUM 5 24 120 LT -105: INCANDESCENT SPHERICAL PENDANT 1 12 12 requirements. All alteration lighting controls shall be commissioned per 0408.3• Lighting Controls Interior New wiring installed to serve added fixtures and/or fixtures relocated to new circuit(s) lighting ❑ Parking garage ❑ Exterior lighting ❑ LT -106: INCANDESCENT INDUSTRIAL PENDANT 2 150 300 LT -115: FOUR PENDANT LINEAR CHANDELIER 1 4 6 9 6 LT -119: MULTI -TIRED DRUM PENDANT 3 24 72 LT -107 PENDANT 1 36 36 New or moved lighting panel ❑ ❑ ❑ LT -125: OVER -MIRROR SCONCE 4 72 288 LT -126: LINEAR FLUSH MOUNT 10 114 1140 Interior space is reconfigured - luminaires unchanged or relocated only , EXISTING CANS (12W) 50 12 600 ` ❑ No changes are being made to the Interior or exterior lighting systems and existing space uses and configuration are not changed. New wiring or circuit - For interior lighting, provide required manual controls per 0405.2.3, occupancy sensor controls per C405.2.1, daylight responsive controls per 0405.2.4 and application specific lighting controls per C405.2.5. For exterior lighting. provide required controls per C405.2.7. New or movedpanel -Provide all applicable lighting controls as noted for New Wring and automatic pp g gg time switch controls per C405.2.2. Reconfigured interior space - Provide all required lighting controls that apply to a new interior space. Application specific lighting control provisions per C405.2.5 do not apply to reconfigured spaces. Proposed Retail Disp ay Lighting from LTG -INT -DISPLAY Total Proposed Watts may not exceed Total Allowed Watts for Interior Lighting Total Proposed Watts 3010 Interior Lighting Power Allowance COMPLIES Note 1- List all unique space types per Table C405.4.2(2) that occur in the project scope. Select space type category per from drop down menu. Note 2 - Indicate ceiling height for atriums and spaces utilizing the ceiling height adjustment per Table C405.4.2(2), Footnotes d thru f. Note 3 - List all proposed lighting fixtures including exempt lighting equipment and existing -to -remain fixtures. Note 4 - For proposed Fixture Description, indicate fixture type, lamp type (e.g. T-8), number of lamps in the fixture, and ballast type (if Included). For track lighting, List the length of the track (in feet) in addition to the fixture, lamp, and ballast information. Note 5 - For lighting equipment eligible for exemption per 0405.4.1, note exception number and leave Watts/Fixture blank. Note 6 - Existing -to -remain fixtures shall be included in the Proposed Lighting Wattage table in the same manner as new fixtures. identify as existing in fixture description. Note 7 - For proposed Watts/Fixture enter the luminaire wattage for installed lamp and ballast using manufacturer or other approved source. For luminaires with screw-in lamps, enter the manufacturer's listed maximum input wattage of the fixture (not the lamp wattage). For low voltage lighting, enter the wattage of the transformer. For line voltage track/busway systems, enter the larger of the attached luminaire wattage or 50 watts/lineal foot, or enter the wattage limit of permanent current limiting device. Note 8 - Lobby Art/Exhibit Display Allowance is independent of the Maximum Allowed Lighting Wattage. Note 9 - Calculation Area Details: a. Lighting fixtures in a building addition may comply as a stand alone project, or they may be combined with the overall existing building lighting systems to demonstrate compliance. Refer to C502.1. Change of Space Use ❑ Existing interior lighting systems in areas under -going a change in space use are upgraded to comply with CPAs for the new space types per Tables C405.4.2(1) or 0405.4.2(2). Identify interior spaces requiring LPD upgrade to the current Code in Proposed Lighting Wattage table in LTG -INT -BLD or LTG -INT -SPACE form. b(vol3 SEPARATE PERMIT AND APPROVAL REQUIRED 10 11 12 13 14 HOMEWOOD SUITES BY HILTON" Seattle/Tukwila, WA Inn Code: SEATK FRC DESIGN WORLDWIDE 311 Elm Street Suite 600 Cincinnati, OH 45202 www.FRCH.com 513 241 3000 Owner 804.727.1757 Apple Hospitality REIT, Inc. 814 East Main Street Richmond, VA 23219 Chris Zeigler Architect 513.241.3000 FRCH Design Worldwide 1: 513.241.5015 311 Elm Street, Suite 600 Cincinnati, OH 45202-2706 Mike Keifling Interior Design 513.241.3000 FRCH Design Worldwide f: 513.241.5015 311 Elm Street, Suite 600 Cincinnati, OH 45202-2706 Raejean Downs ISSUED INFORMATION OWNER REVIEW SET: BRAND REVIEW SET: ISSUED: 07.29.2016 REVISIONS: ,o° . Rpe000 00 06 T. °' \00•1a 0 la 1.- O %%ce• 0 • . »s ',.• . ` o_-' X16 AVM. 000VM. *00007' RoBIsoN ENGINEERING, INC 19401 40TH AVE W, SUITE 302 LYNNWooD, WA 98036 206-364-3343 TEL / 425-835-0098 FAX PROJECT INFORMATION INTERIOR & EXTERIOR RENOVATION Homewood Suites Tukwila 6955 Fort Dent Way Tukwila, WA 98188-2554 PROJECT NUMBER: 032609.000 SHEET INFORMATION LIGHTING COMPLIANCE ENERGY FORMSECEIVL. E DRAWN BY: BK, AS �'I1 �'' 01- l UKv' AUG 2 3 20 REVIEWED BY: RR SCALE: VARIES PERMIT CEN1 AUTHORIZED FOR: PERMIT REVIEW K J H G F E D C B A L 10 11 12 13 UNDER COUNTER MICROWAV 28 60"AFF 14 GENERAL NOTES: 1. REFER TO ARCHITECTURAL DRAWINGS TO COORDINATE MOUNTING HEIGHTS. 2. ELECTRICAL CONTRACTOR TO COORDINATE ALL BUILDING ENVELOPE PENETRATIONS WITH GENERAL CONTRACTOR AND ARCHITECT, SEALING AND FLUSHING METHODS PER LANDLORD REQUIREMENTS. 3. THESE ELECTRICAL DRAWINGS ARE DIAGRAMMATIC IN NATURE; THEREFORE THE CONTRACTOR SHALL COORDINATE ALL ELECTRICAL EQUIPMENT AND DEVICE LOCATIONS WITH ARCHITECTURAL, MECHANICAL, AND PLUMBING DIVISIONS PRIOR TO ROUGH—IN. REFER TO AND COORDINATE WITH ARCHITECTURAL, MECHANICAL, AND PLUMBING DRAWINGS FOR ADDITIONAL WORK THAT IS REQUIRED BY THE CONTRACTOR. FLAGGED NOTES ► EXISTING LOW VOLTAGE EQUIPMENT RACK SHALL BE RELOCATED TO SECOND FLOOR STORAGE ROOM. ELECTRICAL CONTRACTOR SHALL COORDINATE WITH DESIGN BUILD LOW VOLTAGE CONTRACTOR TO ENSURE ADEQUATE POWER IS PROVIDED IS PROVIDE TO ACCOMMODATE LOW VOLTAGE EQUIPMENT. FREEZER REFRIG. LLB -38 LLA -42 LLA -40 NEW FLOOR OUTLETS TO POWER FURNITURE/MILLWORK. TRENCH EXISTING SLAB AS REQUIRED. VERIFY LOCATION OF POWER, VOICE, AND DATA DEVICES WITH PROJECT MANAGER PRIOR TO INSTALLATION. ELECTRICAL CONTRACTOR TO VERIFY AND USE EXISTING CIRCUITS WHEN POSSIBLE. RELOCATED POWER, DATA, AND VOICE. VERIFY LOCATION WITH PROJECT MANAGER PRIOR TO INSTALLATION. ELECTRICAL CONTRACTOR SHALL MAKE FINAL CONNECTION OF COMMUNICATIONS CONDUIT TO BASE FEED. COORDINATE INSTALLATION WITH FURNITURE SUPPLIER. PROVIDE (2) 1" CONDUITS FROM J—BOX TO CEILING FOR COMM. ELECTRICAL CONTRACTOR SHALL MAKE FINAL CONNECTION TO BASE FEED. COORDINATE INSTALLATION WITH FURNITURE SUPPLIER. PROVIDE 3/4" CONDUITS FROM J—BOX TO CEILING SPACE FOR POWER. NEW QUAD FLOOR BOX FOR RECEPTION DESK. TRENCH ISTING SLAB AS REQUIRED. ABOVE COUNTER ABOVE COUNTER POWER PLAN -LEVEL 1 SCALE: 3/16" = 1'-0" bo.43e SEPARATE PERMIT AND APPROVAL RECU!RED HOMEWOOD .. - SUITES BY HILTON' Seattle/Tukwila, WA Inn Code: SEATK FRC DESIGN WORLDWIDE 311 Elm Street Suite 600 Cincinnati, OH 45202 www.FRCH.com 513 241 3000 Owner 804.727.1757 Apple Hospitality REIT, Inc. 814 East Main Street Richmond, VA 23219 Chris Zeigler Architect 513.241.3000 FRCH Design Worldwide f: 513.241.5015 311 Elm Street, Suite 600 Cincinnati, OH 45202-2706 Mike Keifling Interior Design 513.241.3000 FRCH Design Worldwide 1: 513.241.5015 311 Elm Street, Suite 600 Cincinnati, OH 45202-2706 Raejean Downs ISSUED INFORMATION OWNER REVIEW SET: BRAND REVIEW SET: ISSUED: 07.29.2016 REVISIONS: O03c1OOa, o :°. •.off' R.ei�A ❑_ Da a 'o ': ' .9.. '' ' ,16 I' OVAL mo°p7�29 a0❑n❑0o RoBIsoN ENGINEERING, INC 1 940 1 40TH AVE W, SUITE 302 LYNNWOOD, WA 98036 206-364-3343 TEL / 425-835-0098 FAX PROJECT INFORMATION INTERIOR & EXTERIOR RENOVATION Homewood Suites Tukwila 6955 Fort DentWay Tukwila, WA 98188-2554 PROJECT NUMBER: 032609.000 SHEET INFORMATION MAIN BUILDING LEVEL el POWERIVED DRAWN BY: BK, A�SITY OF .1 U K W I L P REVIEWED BY: RR AUG 2 2016 SCALE: VARIES PERMIT CENTER AUTHORIZED FOR: PERMIT REVIEW E2.0 13 14 �-- r -i-- LJ GENERAL NOTES: 1. REFER TO ARCHITECTURAL DRAWINGS TO COORDINATE MOUNTING HEIGHTS. 2. ELECTRICAL CONTRACTOR TO COORDINATE ALL BUILDING ENVELOPE PENETRATIONS WITH GENERAL CONTRACTOR AND ARCHITECT, SEALING AND FLUSHING METHODS PER LANDLORD REQUIREMENTS. 3. THESE ELECTRICAL DRAWINGS ARE DIAGRAMMATIC IN NATURE; THEREFORE THE CONTRACTOR SHALL COORDINATE ALL ELECTRiCAL EQUIPMENT AND DEVICE LOCATIONS WITH ARCHITECTURAL, MECHANICAL, AND PLUMBING DIVISIONS PRIOR TO ROUGH—IN. REFER TO AND COORDINATE WITH ARCHITECTURAL, MECHANICAL, AND PLUMBING DRAWINGS FOR ADDITIONAL WORK THAT IS REQUIRED BY THE CONTRACTOR. FLAGGED NOTES CONNECTION LOCATED IN 3RD FLOOR ATTIC SPACE. 10 11 12 13 14 PROVIDE NEW PANEL ELECTRICAL ROOM. TO DETERMINE BEST CIRCUIT FROM WHICH NEW PANEL. HP -1 8.5KVA,208V3P4W AHU-1 11.529KVA,208V3P3W "M" IN CONTRACTOR AVAILABLE TO FEED vv,n, ) ( JVL! J 5- 1 L I C s - s POWER PLAN -MEETING ROOM SCALE: 3/16" = 1P-0" - A. SEPARATE ---diaLzFllwrg4D APPROVAL REQUIRED 411. 9 10 11 12 13 14 HOMEWOOD SUITES BY HILTON" Seattle/Tukwila, WA Inn Code: SEATK Panel VI ROOM MOUNTING FLUSH FED FROM UTILITY NOTE VOLTS 208Y/120V 3P 4W AIC 22,000 BUS AMPS 125 MAIN BKR 125 NEUTRAL 100% LUGS STANDARD CKT CKT LOAD Chris Zeigler Architect 513.241.3000 FRCH Design Worldwide f: 513.241.5015 CKT CKT LOAD Interior Design 513.241.3000 FRCH Design Worldwide f: 513.241.5015 # BKR KVA CIRCUIT DESCRIPTION OWNER REVIEW SET: BRAND REVIEW SET: # BKR KVA CIRCUIT DESCRIPTION 1 40/3 8.5 HP -1 a 2 20/1 0 F <so SPARE 3 I ENGINEERING, INC 19401 40TH AVE W, SUITE 302 LYNNWOOD, WA 98036 b 4 20/1 0 Homewood Suites Tukwila SPARE 5 1 SHEET INFORMATION BUILDING 1 LEVEL 2 c 6 20/1 0 REVIEWED BY: RR SPARE 7 15/1 0.133 EF -1 a 8 20/1 0 SPARE 9 40/3 11.5 AHU-1 b 10 20/1 0 SPARE 11 1 c 12 20/1 0 SPARE 13 I a 14 20/1 0 SPARE 15 20/1 0 SPARE b 16 20/1 0 SPARE 17 20/1 0 SPARE c 18 20/1 0 SPARE 19 20/1 0 SPARE a 20 20/1 0 SPARE 21 20/1 0 SPARE b 22 20/1 0 SPARE 23 20/1 0 SPARE c 24 20/1 0 SPARE CONN KVA CALC KVA CONN KVA CALC KVA LIGHTING 0 0 (125%) CONTINUOUS 0 0 (125%) LARGEST MOTOR 11.5 14.4 (125%) HEATING 8.5 8.5 (100%) OTHER MOTORS 0.133 0.133 (100%) COOLING 0 0 (N/A) RECEPTACLES 0 0 (50%>10) NONCONTINUOUS 0 0 (100%) KITCHEN EQUIP 0 0 (N/A) DIVERSE 0 0 (N/A) METERBANK 0 0 (0%) METERED DEMAND 0 0 (125%) TOTAL KVA 20.2 23 BALANCED 3—PHASE AMPS 64 PHASE BALANCE PERCENT: PHASE A 101% PHASE B 99.3% PHASE C 99.3% PROVIDE NEW PANEL ELECTRICAL ROOM. TO DETERMINE BEST CIRCUIT FROM WHICH NEW PANEL. HP -1 8.5KVA,208V3P4W AHU-1 11.529KVA,208V3P3W "M" IN CONTRACTOR AVAILABLE TO FEED vv,n, ) ( JVL! J 5- 1 L I C s - s POWER PLAN -MEETING ROOM SCALE: 3/16" = 1P-0" - A. SEPARATE ---diaLzFllwrg4D APPROVAL REQUIRED 411. 9 10 11 12 13 14 HOMEWOOD SUITES BY HILTON" Seattle/Tukwila, WA Inn Code: SEATK FRC H DESIGN WORLDWIDE 311 Elm Street Suite 600 Cincinnati, OH 45202 www.FRCH.com 513 241 3000 Owner 804.727.1757 Apple Hospitality REIT, Inc. 814 East Main Street Richmond, VA 23219 Chris Zeigler Architect 513.241.3000 FRCH Design Worldwide f: 513.241.5015 311 Elm Street, Suite 600 Cincinnati, OH 45202-2706 Mike Keifling Interior Design 513.241.3000 FRCH Design Worldwide f: 513.241.5015 311 Elm Street, Suite 600 Cincinnati, OH 45202-2706 Raejean Downs ISSUED INFORMATION OWNER REVIEW SET: BRAND REVIEW SET: ISSUED: 07.29.2016 REVISIONS: 000000000 .o° �` ..Roe" F <so r 0t�qu... o0007�29 �QtinoO° RoBIsoN ENGINEERING, INC 19401 40TH AVE W, SUITE 302 LYNNWOOD, WA 98036 206-364-3343 TEL / 425-835-0098 FAX PROJECT INFORMATION INTERIOR & EXTERIOR RENOVATION Homewood Suites Tukwila 6955 Fort Dent Way Tukwila, WA 98188-2554 PROJECT NUMBER: 032609.000 SHEET INFORMATION BUILDING 1 LEVEL 2 POWER RECEIVED DRAWN BY: BKCA�1 Y 01- I U I� VV I L A AUG 2 3 2016 REVIEWED BY: RR SCALE: VARIES PERMIT CENTER AUTHORIZED FOR: PERMIT REVIEW K J FI G F E D C A 4 5 6 7 8 9 10 11 12 13 14 NEW NEW Panel ROOM VOLTS 208Y/120V 3P 4W AIC 22,000 LLA MOUNTING FLUSH BUS AMPS 200 MAIN BKR MLO FED FROM UTILITY NEUTRAL 100% LUGS STANDARD NOTE T CKT CKT BKR LOAD KVA CIRCUIT DESCRIPTION MODEL CKT # CKT BKR LOAD KVA CIRCUIT DESCRIPTION 1 20/1 0.5 EXECUTIVE OUTLETS a 2 20/1 0.5 ENTRY LTGS 3 20/1 0.5 UNKNOWN b 4 20/1 0.8 CORRIDOR LTG 5 20/1 0.7 EXERCISE OUTLETS c 6 20/1 0.8 CORRIDOR LTG 7 20/1 0.6 GREAT RM. OUTLETS a 8 20/1 0.8 LOBBY LTG 9 20/1 0.8 GREAT RM & BOARD RM b 10 20/1 0.6 HALL & STAIRS LTG LIGHTING FUNCTIONAL PENDANT OUTLET RESTORATION HARDWARE: 68060923 SHEL 120 ELECTRONIC (1) 12W INCANDESCENT 12 11 20/1 0.4 UPSTAIRS STORAGE LTG c 12 20/1 0.6 WALL SCONCE LTG 13 20/1 0.4 UPSTAIRS STORAGE LTG a 14 20/1 0.5 GREAT RM LTG 15 20/1 1 WASHER b 16 20/1 0.6 PANTRY LTG 17 20/1 1 WASHER c 18 20/1 0.6 GREAT RM LTG 19 20/1 0.8 ATTIC LTG & OUTLETS a 20 20/1 1 FIRE ALARM PANEL 21 20/1 1 DRYERS b 22 20/1 0.8 SATALITE COMM. 23 20/1 1 DRYERS c 24 20/1 0.6 PHONE 25 20/1 1 COMPUTER RM OUTLETS a 26 20/1 0.6 PHONE 27 20/1 0.7 OPERATIONS OUTLETS b 28 20/1 1.36 GFCI RECEPTACLE, RECEPTACLE, UNDER COUNTER RESTORATION HARDWARE: 68050059 BRZ 120 ELECTRONIC (1) 24W INCANDESCENT 24 FIXTURE SOCKET(S) SHALL BE LABELED WITH A MAX RATED WATTAGE OF 24W MICROWAVE 29 20/1 0.8 UNKNOWN c 30 20/1 0.8 SALES OUTLET 31 20/1 1.26 CONTROLLED RECEPTACLE, RECEPTACLE, TV a 32 20/1 0.8 UNKNOWN 33 20/1 0.828 COLD PAN, FLOOR DUPLEX b 34 20/1 0.8 SALES OUTLETS 35 20/1 0 SPARE c 36 20/1 0.8 HALL & GENERAL MANAGER 37 20/1 0 SPARE a 38 20/1 1.3 TREADMILL 39 20/1 0 SPARE b 40 20/1 1.3 TREADMILL 41 20/1 0 SPARE c 42 20/1 1.3 TREADMILL CONN KVA CALC KVA CONN KVA CALC KVA LIGHTING 7 8.75 (125%) CONTINUOUS 0 0 (125%) LARGEST MOTOR 0 0 (N/A) HEATING 0 0 (N/A) OTHER MOTORS 0 0 (100%) COOLING 0 0 (N/A) RECEPTACLES 23.5 16.8 (50%>10) NONCONTINUOUS 0 0 (100%) KITCHEN EQUIP 0 0 (N/A) DIVERSE 0 0 (N/A) METERBANK 0 0 (0%) METERED DEMAND 0 0 (125%) TOTAL KVA 30.5 25.5 BALANCED 3-PHASE AMPS 70.8 PHASE BALANCE PERCENT: PHASE A 98.8% PHASE B 109% PHASE C 92.3% Panel ROOM VOLTS 208Y/120V 3P 4W AIC 22,000 MOUNTING FLUSH BUS AMPS 200 MAIN BKR MLO LLBFED FROM UTILITY NEUTRAL 100% LUGS STANDARD NOTE CKT CKT LOAD CKT CKT LOAD BKR KVA CIRCUIT DESCRIPTION BKR KVA CIRCUIT DESCRIPTION 1 20/1 0.7 REGESTRATION & SUITE SHOP a 2 20/1 0.5 TREAD MILL LTG 3 20/1 0.7 COMPUTER SERVICE & SALES b 4 20/1 0.7 COMPUTER RM OPERATION LTG 5 20/1 0.5 GENERAL MANAGER LTG c 6 20/1 0.7 COMPUTER RM 7 20/1 0.5 EXECUTIVE LTG a 8 20/1 0.7 COMPUTER RM 9 20/1 0.4 BATHROOM LTG b 10 20/1 0.7 COMPUTER RM 11 20/1 0.6 PHOTOCELL AND LODGE c 12 20/1 0.7 COMPUTER RM ENTRY 13 20/1 0.8 EXERCISE & LAUNDRY LTG a 14 20/1 0.7 COMPUTER RM 15 20/1 0.7 STREET LTG b 16 20/1 0.6 REGISTRATION OUTLETS 17 20/1 0.7 STREET LTG c 18 20/1 0.6 REGISTRATION RM 19 20/1 0.5 TREAD MILL a 20 20/1 0.6 REGISTRATION RM 21 20/1 0.8 FOOD SERVICE LTG b 22 20/1 0.6 REGISTRATION RM 23 20/1 0.3 BOARD RM LTG c 24 20/1 0.6 REGISTRATION RM 25 20/1 0.3 PORCH LTG a 26 20/1 0.5 SPRINKLER RM 27 20/1 0.3 PORCH LTG b 28 20/1 0.624 REFRIG. 29 20/1 0.4 FANS c 30 20/1 1.56 FREEZER 31 20/1 0.6 ATTIC FANS a 32 20/1 1.08 FLOOR QUAD, RECEPTACLE 33 20/1 0.4 WIRELESS b 34 20/1 0.72 CONTROLLED RECEPTACLE 35 20/1 0.36 FLOOR DUPLEX, TV c 36 20/1 0.36 GFCI RECEPTACLE 37 20/1 0.7 EMERGENCY LTG a 38 20/1 1.3 TREADMILL 39 20/1 1 GREAT RM. FLOURESCENT b 40 20/1 0.36 RECEPTACLE 41 20/1 0 SPARE c 42 20/1 0.36 RECEPTACLE CONN KVA CALC KVA CONN KVA CALC KVA LIGHTING 9 11.3 (125%) CONTINUOUS 0 0 (125%) LARGEST MOTOR 0.6 0.75 (125%) HEATING 0 0 (N/A) OTHER MOTORS 0.4 0.4 (100%) COOLING 0 0 (N/A) RECEPTACLES 15.8 12.9 (50%>10) NONCONTINUOUS 0 0 (100%) KITCHEN EQUIP 0 0 (N/A) DIVERSE 0 0 (N/A) METERBANK 0 0 (0%) METERED DEMAND 0 0 (125%) TOTAL KVA 25.8 25.3 BALANCED 3-PHASE AMPS 70.3 PHASE BALANCE PERCENT: PHASE A 110% PHASE B 100% PHASE C 89.9% EW EW EW NEW NEW NEW NEW NEW NEW NEW NEW v v C408.3.3 FUNCTIONAL TESTING OF LIGHTING CONTROLS 1. LIGHTING SYSTEM TESTING GOALS: 1.1. TO CONFIRM AND DOCUMENT THAT THE UGH -TING SYSTEM IS INSTALLED AND OPERATES IN COMPUANCE WITH THE 2012 WA STATE ENERGY CODE AND IN COMPUANCE WITH THE MANUFACTURER'S REQUIREMENTS AND THE OWNER'S EXPECTATIONS. 2. FUNCTIONAL TESTING SHALL BE PERFORMED BY THE ELECTRICAL CONTRACTOR IN ACCORDANCE WITH 2012 WA STATE ENERGY CODE SECTION C408.3.1. 3. PLANS TO TEST SYSTEMS AND COMPONENT: 3.1. THE DESIGN INTENT FOR THE UGH11NG SYSTEMS IS TO PROVIDE ILLUMINATION IN ALL OCCUPIED AREAS OF THE FACILITY AT LEVELS TO ALLOW PERSONS TO SAFELY NAVIGATE CORRIDORS AND TENANT SPACES. 3.2. EQUIPMENT TO BE TESTED INCLUDES THE LIGHTING FIXTURES, SWATCHES, PHOTO AND OCCUPANCY CONTROL SYSTEMS AND TIME CONTROLS. 3.3. FUNCTIONS TO BE TESTED INCLUDE THE FOLLOWING: 3.3.1. AUTOMATIC SCHEDULED ON -TIMES. 3.3.2. AUTOMATIC LIGHTING SHUTOFF. 3.3.3. MANUAL UGHITNG ON/OFF CONTROL 3.3.4. CONFIRM THAT THE PLACEMENT, SENSITIVITY AND TIME-OUT ADJUSTMENTS FOR OCCUPANT SENSORS YIELD ACCEPTABLE PERFORMANCE. 3.3.5. CONFIRM THAT TIME SWITCHES AND PROGRAMMABLE SCHEDULE CONTROLS ARE PROGRAMMED TO TURN LIGHTS OFF. 3.3.6. CONFIRM THAT THE PLACEMENT AND SENSITIVITY ADJUSTMENTS FOR PHOTOSENSOR CONTROLS REDUCE ELECTRIC UGHT BASED ON THE AMOUNT OF USABLE DAYLIGHT IN THE SPACE. 3.4. CONDITIONS UNDER WHICH THE TEST SHALL BE PERFORMED: 3.4.1. LIGHTING SYSTEMS TO BE INSTALLED AND SECURED TO STRUCTURE. 3.4.2. POWER AND CONTROL WIRING CONNECTIONS TO BE COMPLETE AND INSTALLED PER CODE. 3.4.3. POWER CONNECTIONS TO BE COMPLETE AND CIRCUIT BREAKERS ON. 3.4.4. ELECTRICIAN TO BE AVAILABLE WITH TOOLS AND MANUFACTURER'S OPERATION MANUAL FOR MAKING ADJUSTMENTS AS NEEDED. 3.4.5. FUNCTIONAL TESTING TEAM TO HAVE PROPER FORMS READY TO FILL OUT AND DOCUMENT TESTS AND RESULTS. 3.4.6. MEASURABLE CRITERIA FOR ACCEPTABLE PERFORMANCE: 3.4.6.1. UGHTS TURN ON OR OFF WHEN SCHEDULED. 3.4.6.2. LIGHTING REDUCTION PROVIDES UNIFORM REDUCTION IN LIGHTING WHEN ACTIVATED. 3.4.6.3. LIGHTS TURN OFF AFTER PRESET TIME-OUT PERIOD. 4. FUNCTIONAL TEST PROCEDURES: 4.1. ROOM OCCUPANCY SENSOR CONTROLS: 4.1.1. ALLOW CONTROL TO AUTOMATICALLY TURN LIGHTS OFF. 4.1.2. ENTER THE ROOM AND OBSERVE THAT THE UGHTS TURN ON AUTOMATICALLY. 4.1.3. CONFIRM THAT THE SENSOR IS IN THE LOCATION SHOWN ON THE PLAN OR IN A LOCATION ACCEPTABLE FOR OPERATION. 4.1.4. REFER TO DRAWINGS AND CONFIRM THAT THE CORRECT UGHTS ARE CONTROLLED BY THE SENSOR BEING TESTED. 4.1.5. EXIT THE SPACE AND 11ME THE AUTOMATIC OFF -DELAY. 4.1.6. RECORD TEST RESULTS ON TEST RESULTS DOCUMENT. 4.2. DAYLIGHT HARVESTING CONTROLS: 4.2.1. MEET WITH THE OWNER AND IDENTIFY THE LIGHTING LEVEL IN FOOTCANDLE SETPOINT THAT IS DESIRED FOR NORMAL OPERATION AT DESK HEIGHT (+30"AFF). 4.2.2. AFTER SUNSET, TURN OFF THE UGHTS ON AND ADJUST THE NORMAL ILLUMINATION LEVEL FOR THE DESIRED FOOTCANDLE LEVEL AT DESK HEIGHT (+30"AFF). 4.2.3. DURING DAYLIGHT HOURS, ADJUST THE PHOTOCONTROLS DIMMING SENSITIVITY AND RANGE TO AUTOMATICALLY DIM THE LIGHTING FIXTURES TO MAINTAIN THE FOOTCANDLE SETPOINT. 4.1.6. RECORD TEST RESULTS ON TEST RESULTS DOCUMENT. ELECTRICAL CONTRACTOR TO UTILIZE THIS FORM OR SIMILAR FOR DOCUMENTING THE FUNCTIONAL TESTING. LUMINAIRE SCHEDULE 2012 WASHINGTON STATE ENERGY CODE SYMBOL C408.3.3 FUNCTIONAL TESTING OF LIGHTING CONTROLS DESCRIPTION MODEL OCCUPANCY SENSORS 11MECLOCKS EXTERIOR PHOTOCELL CONTROL LOCATION/ ROOM/ ZONE/ SIGNS PLACEMENT OK? SENSITIVITY OK? T1ME-OUT SET TO 15 MINUTES? ON-TIME SETTING OFF -TIME SETTING SENSITIVITY SETTING 120 ELECTRONIC (1) 18.5W LED 18.5 Cincinnati, OH 45202-2706 LT-101ERECESSED ® OWNER REVIEW SET: 6"RECESSED DOWNLIGHT GOTHAM: EVO/40/15-6WR/MD/M VOLT/EZ1 /EL 120 ELECTRONIC (1) 18.5W LED 18.5 LT -102 o -Q WALL WALL SCONCE MURRAY FEISS: JOPLIN: WB1564CH 120 ELECTRONIC (1) 12W INCANDESCENT 12 FIXTURE SOCKET(S) SHALL BE LABELED WITH A MAX RATED WATTAGE OF 12W LT -104 ROBISON ENGINEERING, INC PENDANT 18" DRUM PENDANT TBD 120 ELECTRONIC (1) 24W INCANDESCENT 24 FIXTURE SOCKET(S) SHALL BE LABELED WITH A MAX RATED WATTAGE OF 24W Tukwila, WA 98188-2554 O LT -105 LIGHTING FUNCTIONAL PENDANT SPHERICAL PENDANT RESTORATION HARDWARE: 68060923 SHEL 120 ELECTRONIC (1) 12W INCANDESCENT 12 FIXTURE SOCKET(S) SHALL BE LABELED WITH A MAX RATED WATTAGE OF 12W O LT -106 PENDANT INDUSTRIAL PENDANT KICHLER LIGHTING: 26660Z 120 ELECTRONIC (1) 150W INCANDESCENT A21 150 O LT -107 PENDANT 20" PENDANT ROBERT ABBEY: S1912 120 ELECTRONIC (3) 12W INCANDESCENT 36 FIXTURE SOCKET(S) SHALL BE LABELED WITH A MAX RATED WATTAGE OF 12W LT -115 CEILING LUMINAIRE SCHEDULE CALLOUT SYMBOL MOUNTING DESCRIPTION MODEL VOLTAGE TYPE LAMPING WATTAGE NOTES LT -101 Architect 513.241.3000 RECESSED 6" RECESSED DOWNLIGHT GOTHAM: EVO/40/15-6WR/MD/MVOLT/EZ1 120 ELECTRONIC (1) 18.5W LED 18.5 Cincinnati, OH 45202-2706 LT-101ERECESSED ® OWNER REVIEW SET: 6"RECESSED DOWNLIGHT GOTHAM: EVO/40/15-6WR/MD/M VOLT/EZ1 /EL 120 ELECTRONIC (1) 18.5W LED 18.5 LT -102 o -Q WALL WALL SCONCE MURRAY FEISS: JOPLIN: WB1564CH 120 ELECTRONIC (1) 12W INCANDESCENT 12 FIXTURE SOCKET(S) SHALL BE LABELED WITH A MAX RATED WATTAGE OF 12W LT -104 ROBISON ENGINEERING, INC PENDANT 18" DRUM PENDANT TBD 120 ELECTRONIC (1) 24W INCANDESCENT 24 FIXTURE SOCKET(S) SHALL BE LABELED WITH A MAX RATED WATTAGE OF 24W Tukwila, WA 98188-2554 O LT -105 LIGHTING FUNCTIONAL PENDANT SPHERICAL PENDANT RESTORATION HARDWARE: 68060923 SHEL 120 ELECTRONIC (1) 12W INCANDESCENT 12 FIXTURE SOCKET(S) SHALL BE LABELED WITH A MAX RATED WATTAGE OF 12W O LT -106 PENDANT INDUSTRIAL PENDANT KICHLER LIGHTING: 26660Z 120 ELECTRONIC (1) 150W INCANDESCENT A21 150 O LT -107 PENDANT 20" PENDANT ROBERT ABBEY: S1912 120 ELECTRONIC (3) 12W INCANDESCENT 36 FIXTURE SOCKET(S) SHALL BE LABELED WITH A MAX RATED WATTAGE OF 12W LT -115 CEILING FOUR PENDANT LINEAR CHANDELIER ROBERT ABBEY: S2155 120 ELECTRONIC (4) 12W INCANDESCENT 48 FIXTURE SOCKET(S) SHALL BE LABELED WITH A MAX RATED WATTAGE OF 12W LT -119 PENDANT MULTI -TIERED DRUM PENDANT SEASCAPE LAMPS: VICTOR 120 ELECTRONIC (1) 24W INCANDESCENT 24 FIXTURE SOCKET(S) SHALL BE LABELED WITH A MAX RATED WATTAGE OF 24W " LT -125 1}}} tU m CEILING OVER -MIRROR SCONCE KCHLER LIGHTING: 45439N1 120 ELECTRONIC (3) 24W INCANDESCENT 72 FIXTURE SOCKET(S) SHALL BE LABELED WITH A MAX RATED WATTAGE OF 24W LT -126 CEILING LINEAR FLUSH -MOUNT KICHLER LIGHTING: CHELLA 10847SI 120 ELECTRONIC (4) 32W T8 FLUORESCENT 114 LT -300 lill WALL OUTDOOR WALL SCONCE RESTORATION HARDWARE: 68050059 BRZ 120 ELECTRONIC (1) 24W INCANDESCENT 24 FIXTURE SOCKET(S) SHALL BE LABELED WITH A MAX RATED WATTAGE OF 24W SEPARATE PERMIT AND APPROVAL REQUIRED 1 2 3 4 5 6 7 8 9 10 11 12 13 14 COPYRIGHT 2018, ROBISON ENGOQEERING, INC. BKONG F:\883-001 HOMEW00D SUITES TUKWILA - LODGE\011G\E1-2.D110 06-09-2018 09:51 HOMEWOOD r : S BY Seattle/Tukwila, Inn Code: SEATK HILTON" WA FRC DESIGN WORLDWIDE 311 Elm Street Suite 600 Cincinnati, OH 45202 www.FRCH.com 513 241 3000 Owner 804.727.1757 Apple Hospitality REIT, Inc. 814 East Main Street Richmond, VA 23219 Chris Zeigler Architect 513.241.3000 FRCH Design Worldwide f: 513.241.5015 311 Elm Street, Suite 600 Cincinnati, OH 45202-2706 Mike Keifling interior Design 513.241.3000 FRCH Design Worldwide 1: 513.241.5015 311 Elm Street, Suite 600 Cincinnati, OH 45202-2706 Raejean Downs ISSUED INFORMATION OWNER REVIEW SET: BRAND REVIEW SET: ISSUED: 07.29.2016 REVISIONS: voa00000 0 , I`....R4e�%oo • 0 Jif/.:. CJ .0 •. .'"�T .-1g 0000%i`..• .....00a7,29 DDOooOd ROBISON ENGINEERING, INC 1 940 1 40TH AVE W, SUITE 302 LYNNWOOD, WA 98036 206-364-3343 TEL / 425-835-0098 FAx PROJECT INFORMATION INTERIOR & EXTERIOR RENOVATION Homewood Suites Tukwila 6955 Fort Dent Way Tukwila, WA 98188-2554 PROJECT NUMBER: 032609.000 SHEET INFORMATION LIGHTING FUNCTIONAL TESTING & SCHEDU-. ,i S DRAWN BY: BI �Y OF TUKWILA REVIEWED BY: RR AUG 2 3 2016 SCALE: VARIESPERMIT CENTER AUTHORIZED FOR: PERMIT REVIEW 5 6 7 8 9 10 11 12 13 14 GENERAL NOTES ABBREVIATIONS SYMBOLS GENERAL NOTES - MECHANICAL 1. REFERENCE TO RELATED WORK: "REF" INDICATIONS DENOTE WORK COVERED ELSEWHERE (ARCHITECTURAL, STRUCTURAL, CIVIL, ELECTRICAL, LANDSCAPE, OR KITCHEN), OR ITEM BASED ON A SPECIFIC MANUFACTURER'S DIMENSIONS (VERIFY). 2. ELECTRICAL CHARACTERISTICS: REFER TO ELECTRICAL DRAWINGS FOR ELECTRICAL CHARACTERISTICS (VOLTAGES. ETC. OF MECHANICAL EQUIPMENT, UNLESS OTHERWISE INDICATED. 3. CODES: COMPLETE INSTALLATION OF THE MECHANICAL SYSTEM SHALL BE PER THE APPLICABLE BUILDING, MECHANICAL, ENERGY, PLUMBING. FIRE, AND HEALTH CODES AND REGULATIONS AS ADOPTED BY THE LOCAL AHJ. 4. PREPARE AND SUBMIT FOR REVIEW A SHOP DRAWING BASED ON FINAL STRUCTURAL SHOP DRAWINGS FOR LOCATING AND ROUTING ALL DUCTWORK, DAMPERS, EQUIPMENT. PIPING, ETC. A. COORDINATE FLOOR AND BEAM PENETRATIONS WITH STRUCTURAL B. COORDINATE FINAL LOCATION AND ROUTING WITH CEILING, LIGHTS, WALLS, FIRE SPRINKLER PIPING, AND OTHER TRADES WORK. C. INCLUDE ADDITIONAL OFFSETS, ELBOWS, ROUTING, EQUIVALENT DUCT SIZING EXCHANGE, RELOCATING, ETC. AS REQUIRED FOR A COMPLETE OPERATING MECHANICAL SYSTEM. D. PROVIDE SHOP DRAWINGS AT NO ADDITIONAL COST TO THE OWNER. 5. MECHANICAL CONTRACTOR SHALL LOCATE AND COORDINATE EXACT LOCATION OF ALL MECHANICAL EQUIPMENT WITHIN THE STRUCTURE. 6. ACCESS DOORS: COORDINATE WITH ARCHITECT AND LOCATE ALL ACCESS DOORS ON SHOP DRAWINGS PRIOR TO BEGINNING OF CONSTRUCTION. ACCESS DOORS IN FIRE RATED STRUCTURE SHALL BE FIRE RATED. VERIFY ACCESS DOOR LOCATIONS WITH GENERAL CONTRACTOR PRIOR TO BIDDING. 7. RATED PENETRATION: DUCT PENETRATIONS THROUGH RATED ENCLOSURES SHALL BE FIRE/SMOKE DAMPERED PER THE LATEST EDITION OF THE UNDERWRITERS LABORATORIES(UL) FIRE RESISTANCE WITH HOURLY RATINGS FOR THROUGH -PENETRATION FIRE STOPS SYSTEM VOLUME #2, OR SHALL. BE INSTALLED IN STRICT ACCORDANCE WITH THE MANUFACTURER'S UL LISTINGS (3M OR EQUIVALENT). DETERMINE REQUIREMENTS WITH GENERAL CONTRACTOR PRIOR TO BID. 8. EXHAUST OUTLETS: SOURCE -SPECIFIC FANS SHALL BE VENTED TO OUTDOORS WITH A MINIMUM 3' CLEARANCE BETWEEN VENT OUTLETS AND BUILDING OPENINGS, AND 10' MINIMUM BETWEEN VENT OUTLETS AND MECHANICAL AIR INTAKES. 9. ROOF PENETRATIONS: SEE ARCHITECTURAL DRAWINGS FOR ROOF CAP, ROOF CURB. ROOF DRAIN, AND VTR DETAILS. 10. EXPOSED PIPING: PROVIDE CHROME PLATING FOR EXPOSED PIPING IN FINISHED ROOMS. 11. PENETRATIONS: PROVIDE ESCUTCHEON PLATES FOR EXPOSED PIPING PENETRATIONS AND SHEET METAL FLASHING FOR EXPOSED DUCTWORK PENETRATIONS. 12. SHAFT AND PLENUM CONNECTIONS: SEAL CONNECTIONS TO AIR SHAFTS AIRTIGHT. PROVIDE AIRTIGHT SEAL AROUND PENETRATIONS IN AIR PLENUMS. 13. LIGHT FIXTURE CLEARANCE: COORDINATE LOCATIONS OF MECHANICAL WORK TO PROVIDE CLEARANCES OVER LIGHTING FIXTURES FOR REMOVAL AND REPLACEMENT. 14. CABLE TRAYS: DUCTWORK AND PIPING INSTALLED ADJACENT TO ELECTRICAL CABLE TRAYS SHALL ALLOW MINIMUM ACCESS OF 6" ABOVE AND TO THE SIDE OF CABLE TRAYS. 15. MOTORS: COMPLY WITH ENERGY CODE ENFORCED BY AHJ FOR MINIMUM EFFICIENCIES UNDER FULL LOAD. 16. ACCESS CLEARANCES FOR MAINTENANCE AND REPLACEMENT: VERIFY PHYSICAL DIMENSIONS OF EQUIPMENT TO ENSURE THAT ACCESS CLEARANCES CAN BE MET. COORDINATE LOCATIONS OF MECHANICAL WORK AND WORK OF OTHER TRADES TO PROVIDE ACCESS CLEARANCES FOR SERVICE AND MAINTENANCE. COORDINATION REQUIREMENTS 1. PIPING: COORDINATE WITH STRUCTURAL FOR EXACT LOCATION OF ALL STRUCTURAL FRAMING AND FOOTINGS AND FINALIZE THE EXACT ROUTING OF ALL PIPES WITH STRUCTURAL AND AT THE SITE PRIOR AND DURING THE CONSTRUCTION. 2. DUCTWORK: LOCATE AND COORDINATE THE EXACT LOCATION OF DUCTWORK WITH STRUCTURAL PLANS AND WITH THE GENERAL CONTRACTOR PRIOR TO INSTALLATION OF ANY STRUCTURE OR EQUIPMENT. COORDINATE WITH FRAMING CONTRACTOR TO ASSURE JOIST SPACES LINE UP WHEN DUCTWORK MUST PASS THROUGH DIFFERENT JOIST SPACES. 3. ADJUSTMENTS: ALL EQUIPMENT, MOTORS, FANS GAS BURNERS, IGNITION DEVICES, DRIVES, ETC. SHALL BE ADJUSTED AND BALANCED TO OPERATE AT SPECIFIED RATINGS AS REQUIRED FOR THIS PROJECT SITE AND ACCOUNTING FOR ELEVATION ABOVE SEA LEVEL 4. APPROVALS: MECHANICAL AND PLUMBING EQUIPMENT SHALL BE APPROVED FOR INSTALLATION IN THE PROJECT LOCATION AND SHALL HAVE ALL CERTIFICATIONS AND RATINGS TO MEET ALL ENERGY, POLLUTION, ENVIRONMENTAL. SEISMIC. ETC. CODES AND REGULATIONS. THE CONTRACTOR SHALL COORDINATE WITH HIS MANUFACTURE SUPPLIERS AND SHALL INCLUDE ALL COSTS REQUIRED TO MEET THESE REQUIREMENTS IN HIS BID. 5. FIRE PROTECTION: CONTRACTOR SHALL PROVIDE A FULLY DESIGNED FIRE PROTECTION SPRINKLER SYSTEM IN COMPLIANCE WITH NEPA AND LOCAL CODES. PROVIDE DESIGN, PERMITS, MATERIALS. INSTALLATION, TESTING AND ALL OTHER FOR A FULLY OPERATIONAL SYSTEM. LOCATION OF ALL PIPING TO BE COORDINATED WITH OTHER TRADES. 6. FIREPLACES: COORDINATE WITH THE GENERAL CONTRACTOR TO DETERMINE GAS FIREPLACE FLUE AND COMBUSTION AIR DUCTWORK REQUIREMENTS PRIOR TO BIDDING. PIPING NOTES 1. DISASSEMBLY PROVISIONS: PROVIDE UNIONS OR FLANGES AT PIPING CONNECTIONS TO EQUIPMENT, COILS, TRAPS, CONTROL VALVES, AND OTHER COMPONENTS TO ALLOW DISASSEMBLY FOR MAINTENANCE. 2. REDUCERS: PROVIDE AS REQUIRED FROM LINE PIPE SIZE TO EQUIPMENT, TRAP, COIL, AND CONTROL VALVE CONNECTION SIZES. 3. OFFSETS: PROVIDE FOR BRANCH LINES TO EQUIPMENT. 4. DIELECTRIC UNIONS: PROVIDE AT CONNECTIONS OF DISSIMILAR PIPE. 5. REFRIGERANT PIPING: PROVIDE SIZING & INSTALLATION IN STRICT ACCORDANCE WITH MANUFACTURER'S INSTRUCTIONS. 6. CONDENSATE DRAIN: PROVIDE A P -TRAP FOR EACH HVAC UNIT CONDENSATE PAN WITH PLUG TEES FOR CLEANING. CONDENSATE DRAINS SHALL BE DISCHARGED TO AN INDIRECT WASTE OR OUTSIDE. INSULATION/LINING NOTES 1. ENERGY CODE: AS A MINIMUM, COMPLY WITH THICKNESSES AND TYPES LISTED IN ENERGY CODE ENFORCED BY AHJ. 2. EXTENT OF INTERNAL DUCT LINING: A. GRILLE AND DIFFUSER BOXES AND BOOTS. B. TRANSFER DUCTS. C. THE FIRST 10 FEET OF SUPPLY AND RETURN DUCTWORK FROM THE AIR HANDLER. 3. EXTENT OF EXTERNAL DUCT INSULATION: A. SUPPLY AND RETURN AIR IN UNCONDITIONED SPACES, MECHANICAL ROOMS, ELECTRICAL ROOMS, AND EQUIPMENT ROOMS NOT SPECIFIED TO BE INTERNALLY LINED. B. SUPPLY AIR ABOVE CEILINGS OR EXPOSED NOT SPECIFIED TO BE INTERNALLY LINED. C. OUTDOOR AIR INTAKE. 4. MISCELLANEOUS DUCT FITTINGS (CONICAL TAKEOFFS, ETC.): WRAP WITH INSULATION FOR CONDENSATION CONTROL PLAN NOTES 1. DUCTWORK SHALL BE METALLIC DUCTWORK 2. TEST AND BALANCE WORK SHALL BE PERFORMED BY AN INDEPENDENT TEST AND BALANCE AGENCY. PROVIDE (3) COPIES OF TEST AND BALANCE REPORT TO OWNER. 3. COORDINATE DUCTWORK WITH MISCELLANEOUS OBSTRUCTIONS IN CEILING SPACE. 4. RESTROOM EXHAUST SHALL BE A MINIMUM OF 10' FROM ANY MECHANICAL OUTSIDE AIR INTAKES. 5. ROUTE DUCTWORK UNDERNEATH JOISTS UON. 6. TRANSITION DUCT UNDER BEAMS AND DUCTS. FIELD VERIFY AVAILABLE CEILING CAVITY DIMENSIONS. 7. COORDINATE MOUNTING HEIGHT OF DIFFUSERS WITH ARCHITECTURAL PLANS. SHEET METAL NOTES 1. REFERENCE: SMACNA HVAC DUCT CONSTRUCTION STANDARDS, METAL AND FLEXIBLE, CURRENT EDITION. . CLEARANCE: COORDINATE DUCTWORK WITH MISCELLANEOUS OBSTRUCTIONS IN CEILING SPACE. 3. ROUND ELBOWS AND OFFSETS: FULL RADIUS (R/D = 1.5), 5 -PIECE SEGMENTED OR STAMPED. REFER TO SMACNA HVAC FIG 2-7, 3-3. DO NOT USE ANGLED OFFSET (TYPE 1). MITERED OFFSET (TYPE 2) MAY BE USED UP TO 30 DEGREE OFFSET ANGLE. 4. ROUND TEES AND LATERALS: CONICAL TEE PER SMACNA HVAC FIG 3-5; DO NOT USE STRAIGHT TEE; DO NOT USE CONICAL SADDLE TAP FOR EXPOSED DUCTWORK IN FINISHED SPACES. 90 -DEGREE TEE WITH OVAL TO ROUND TAP, LATERAL, AND 45 -DEGREE RECTANGULAR LEAD-IN PER SMACNA HVAC FIG 3-4. 5. RECTANGULAR ELBOWS AND OFFSETS: FULL RADIUS WHERE SPACE PERMITS. R/W = 1.5; OTHERWISE USE SQUARE CORNER ELBOW WITH TURNING VANES. 6. RECTANGULAR DIVIDED FLOW FITTINGS: USE GENERALLY, EXCEPT BRANCHES TO TERMINALS; SMACNA HVAC FIG 2-5, TYPES 1, 2, 4A, AND 4B. DO NOT USE TYPE 3. 7. TURNING VANES: H.E.P. MANUFACTURER OR APPROVED HIGH EFFICIENCY PROFILE AIRFOIL TYPE FOR RECTANGULAR SQUARE THROAT ELBOWS. ACOUSTICAL TYPE FOR RETURN AIR MITERED ELBOWS. 8. TAKEOFFS TO OPENINGS: CONICAL TYPE WITH VOLUME DAMPER FOR ROUND DUCT BRANCHES PER SMACNA HVAC FIG 2-6, MINIMUM INLET DIAMETER 2 INCHES LARGER THAN DUCT SIZE. 45 DEGREE ENTRY FITTING FOR RECTANGULAR DUCT BRANCHES PER SMACNA HVAC FIG 2-6. 9. FLEXIBLE CONNECTIONS: PROVIDE AT EACH DUCT CONNECTION TO FANS, PACKAGED HVAC EQUIPMENT, EXTERNALLY ISOLATED AIR HANDLING UNITS, FAN COIL UNITS, AND SIMILAR EQUIPMENT. EXCEPTION: EQUIPMENT IN CORRIDOR CEILING SPACES WHERE FIRE RATING IS REQUIRED. HVAC NOTES 1. ATTACHMENTS: AIR DISTRIBUTION OUTLETS AND LOUVERS SHALL HAVE ALL REQUIRED ACCESSORIES AND ATTACHMENTS FOR A COMPLETE CONNECTION TO THE SPECIFIC TYPE OF STRUCTURE THAT THEY ARE BEING ATTACHED TO. THIS INCLUDES, BUT IS NOT LIMITED TO, EXTERIOR BRICKS, GWB WALLS, GWB CEILING, ETC. 2. DUCTWORK: DUCTWORK SHALL BE SMOOTH SHEET METAL (CLASS -1). DUCTWORK THROUGH FIRE RATED STRUCTURE AND FLOOR SHALL BE MIN. 26 GA. STEEL MAXIMUM LENGTH OF FLEXIBLE DUCTS SHALL BE 5'-0", UNLESS OTHERWISE NOTED ON DRAWINGS. DUCTWORK SIZES SHOWN ARE INSIDE CLEAR DIMENSIONS. 3. VOLUME DAMPERS: PROVIDE AN ACCESSIBLE MANUAL VOLUME DAMPER FOR EACH SUPPLY, RETURN, OSA, AND EXHAUST OPENING, LOCATED AS FAR UPSTREAM AS POSSIBLE FROM THE OPENING. PROVIDE A MANUAL VOLUME DAMPER FOR BRANCH MAINS SERVING MORE THAN ONE OPENING. VOLUME DAMPERS IN NON -ACCESSIBLE CEILINGS SHALL HAVE A CONTROL ARM EXTENDED TO AN ACCESSIBLE LOCATION. 4. SEISMIC: PROVIDE SEISMIC RESTRAINTS FOR MECHANICAL EQUIPMENT, PIPING, AND DUCTWORK PER SMACNA AND LOCAL REGULATIONS. 5. FILTER CLEARANCE: PROVIDE ADEQUATE CLEARANCE FOR CHANGING AIR FILTERS. 6. DUCTWORK AND PIPING OUTSIDE OF MECHANICAL ROOMS SHALL BE CONCEALED, COORDINATE WITH THE GENERAL CONTRACTOR TO FUR -OUT AS REQUIRED. 7. FIRE RATINGS: RATED FLOOR/CEILING JOINT SPACES HAVING DUCTWORK INSIDE THEM SHALL BE FIRE/SMOKE PROTECTED TO MAINTAIN THE 1 -HOUR FLOOR/CEIUNG RATING PER LOCAL JURISDICTIONS. EXHAUST DUCTWORK PENETRATING THE 1 -HOUR ROOF/CEILING OR FLOOR/CEIUNG ASSEMBLY SHALL HAVE ACCESSIBLE CEILING FIRE DAMPERS. ALTERNATIVELY, THE EXHAUST DUCTWORK SHALL BE ROUTED INSIDE A RATED SHAFT TO PROTECT THE CEIUNG/ROOF RATING PER THE LOCAL JURISDICTIONS. 8. FRESTOP: PIPE, DUCT AND CONDUIT PENETRATIONS THROUGH RATED ASSEMBLIES SHALL BE FIRE AND SMOKE STOPPED PER CODE. 9. DUCTWORK: DUCTWORK SHALL BE SMOOTH SHEET METAL (CLASS -1). DUCTWORK THROUGH FIRE RATED STRUCTURE AND FLOOR SHALL BE MIN. 26 GA. STEEL MAXIMUM LENGTH OF FLEXIBLE DUCTS SHALL BE 5'-0" UNLESS OTHERWISE NOTED ON DRAWINGS. DUCTWORK SIZES SHOWN ARE INSIDE CLEAR DIMENSIONS. 10. VOLUME DAMPERS: PROVIDE AN ACCESSIBLE MANUAL VOLUME DAMPER FOR EACH SUPPLY, RETURN, OSA AND EXHAUST OPENING, LOCATED AS FAR UPSTREAM AS POSSIBLE FROM THE OPENING. PROVIDE A MANUAL VOLUME DAMPER FOR BRANCH MAINS SERVING MORE THAN ONE OPENING. VOLUME DAMPERS IN NON -ACCESSIBLE CEILING SHALL HAVE A CONTROL ARM EXTENDED TO AN ACCESSIBLE LOCATION. PROVIDE "YOUNG" REGULATOR OR EQUAL EXACT LOCATION OF CONTROL DEVICES VISIBLE IN FINISHED SPACES SHALL BE COORDINATED WITH THE ARCHITECT. 11. CORRIDOR THERMOSTAT: PROVIDE TAMPERPROOF THERMOSTATS IN CORRIDORS. DO NOT PROVIDE PLASTIC GUARDS TO MAKE THE THERMOSTATS TAMPERPROOF. PROVIDE BLANK SECURABLE THERMOSTAT COVERS. ACU AIR CONDITIONING UNIT AFF ABOVE FINISHED FLOOR AHJ AUTHORITY HAVING JURISDICTION AHU AIR HANDLING UNIT BDD BACKDRAFT DAMPER BHP BRAKE HORSEPOWER BTUH BRITISH THERMAL UNIT PER HOUR C COMMON CAP CAPACITY CC COOLING COIL CD CEILING DIFFUSER CFM CUBIC FEET PER MINUTE CLG CEILING, COOLING CO CLEANOUT COMB COMBUSTION CONT CONTINUE, CONTROL COP COEFFICIENT OF PERFORMANCE CWS CHILLED WATER SUPPLY CWR CHILLED WATER RETURN D DIAMETER DB DRY BULB, DECIBEL DIM DIMENSION DISCH DISCHARGE DN DOWN EA EXHAUST AIR EAT ENTERING AIR TEMPERATURE EER ENERGY EFFICIENCY RATIO EF EXHAUST FAN EFF EFFICIENCY EG EXHAUST GRILLE ELEC ELECTRIC ESP EXTERNAL STATIC PRESSURE EXH EXHAUST EXT EXTERIOR, EXTERNAL F FAHRENHEIT FCU FAN COIL UNIT FLR FLOOR FPM FEET PER MINUTE FPS FEET PER SECOND FSD FIRE/SMOKE DAMPER G GAS GAL GALLONS GPM GALLONS PER MINUTE GRD GRILLES. REGISTERS, DIFFUSERS GWB GYPSUM WALLBOARD HD HEAD HORIZ HORIZONTAL HP HORSEPOWER HPU HEAT PUMP UNIT HRU HEAT RECOVERY UNIT HVAC HEATING. VENTILATING. AND AIR CONDITIONING HVU HEATING & VENTILATION UNIT HWR HOT WATER RETURN HWS HOT WATER SUPPLY HX HEAT EXCHANGER ID INDIRECT DRAIN, INSIDE DIAMETER IN INCH KW KILOWATT L LONG, LENGTH LB POUND MBH THOUSAND BTU PER HOUR MECH MECHANICAL MCA MIN. CIRCUIT AMPACITY MOCP MAX. OVER CURRENT PROTECTION MTD MOUNTED OSA OUTDOOR AIR OBD OPPOSED BLADE DAMPER OD OUTSIDE DIMENSION OR DIAMETER OPNG OPENING P PUMP PD PRESSURE DROP. PUMPED DRAIN POC POINT OF CONNECTION PRV PRESSURE REDUCING VALVE PSIG POUNDS PER SQUARE INCH GAUGE RA RETURN AIR RD ROOF DRAIN REF REFERENCE RF RELIEF FAN RG RETURN GRILLE RPM REVOLUTIONS PER MINUTE SA SUPPLY AIR SCH SCHEDULE SF SUPPLY FAN, SQUARE FOOT SENS SENSIBLE SG SUPPLY GRILLE SMACNA SHEET METAL AND AIR CONDITIONING CONTRACTORS NATIONAL ASSOCIATION SO SCREENED OPENING SP STATIC PRESSURE SS STAINLESS STEEL, SANITARY SEWER SQ SQUARE TG TRANSFER GRILLE TYP TYPICAL UH UNIT HEATER UON UNLESS OTHERWISE NOTED ✓ VENT VENT VENTILATION, VENTILATOR VTR VENT THRU ROOF W WASTE, WATT, WIDE WB WET BULB (TEMPERATURE) 2 (DSD EQUIPMENT TYPICAL EQUIPMENT DESIGNATION (EXHAUST FAN SHOWN) ROOM THERMOSTAT OR TEMPERATURE TRANSMITTER DUCT SMOKE DETECTOR 2 GENERAL ARCHITECTURAL BACKGROUND (THIN LINE) NEW MECHANICAL WORK (HEAVY LINE) MATCHLINE OR PROPERTY UNE SECTION INDENTIFICATION (DETAIL SIMILAR) INDICATES DIRECTION OF CUTTING PLANE LETTER INDICATES SECTION 3��(NO. INDICATES DETAIL) SHEET #WHERE SECTION IS DRAWN SHEET # WHERE SECTION IS TAKEN PIPING CONDENSATE DRAINAGE CD G PW RL OL -140E- -140E- FOF SOS FOR ----FOV I NATURAL GAS WASTE (W) PUMPED WASTE (PW) RAIN LEADER (RL) OVERFLOW RAIN LEADER (OL) VENT (V) COLD WATER (CW) HOT WATER, POTABLE, 120'F HOT WATER, POTABLE, TEMPERATURE OTHER THAN 120'F HOT WATER CIRCULATING (HWC), POTABLE, 120'F HOT WATER CIRCULATING (HWC), POTABLE, TEMP OTHER THAN 120'F FUEL OIL FILL FUEL OIL SUPPLY FUEL OIL RETURN FUEL OIL VENT RELIEF VENT IRRIGATION 7 PIPE CAP I PIPE PLUG UNION FLANGE GATE VALVE OR BALL VALVE BALL VALVE PRESSURE REDUCING VALVE (PRV) BREAK IN PIPING OR DUCTWORK CHECK VALVE BALANCING OR PLUG VALVE BALANCING/MEASUING VALVE INDIRECT DRAIN, PIPE TO DRAIN GLOBE VALVE BUTTERFLY VALVE WYE STRAINER WYE STRAINER WITH CAPPED HOSE END BLOWDOWN VALVE AUTOMATIC CONTROL VALVE, 2 -WAY AUTOMATIC CONTROL VALVE, 3 -WAY RELIEF VALVE REDUCED PRESSURE BACKFLOW PREVENTER DOUBLE CHECK VALVE ASSEMBLY t ID ID DCVA }r FLOOR DRAIN -f- HOSE BIBB PRESSURE GAGE THERMOMETER PRESSURE / TEMPERATURE TEST PORT VALVE STATION OR ASSEMBLY PUMP ISOMETRIC FIXTURE CALLOUT PRE -CON MEETING NOTES CONTRACTORS SHALL ATTEND A PRE -CONSTRUCTION MEETING WITH THE ENGINEER FOR THE PURPOSE OF REVIEWING THE WORK PRIOR TO ORDERING ANY EQUIPMENT OR PERFORMING ANY WORK. THE MEETING SHALL BE LOCATED AT THE PROJECT SITE ON A DATE AND TIME TO BE MUTUALLY AGREED. THE MEETING WILL BE A WORKING SESSION. THE MEETING WILL BE FACILITATED BY THE ENGINEER AND THE AGENDA WILL INCLUDE A DETAILED REVIEW OF THE PLANS AND SPECIFICATIONS, CROSS CHECK WITH OTHER TRADES FOR COORDINATION ISSUES, REVIEW OF PROPOSED PRODUCTS, REVIEW OF PLANNED MEANS AND METHODS,AND ON-SITE INVESTIGATION OF FIELD CONDITIONS RELATIVE TO EXISTING CONDITIONS THAT COULD AFFECT THE WORK. PERSONS ATTENDING THE MEETING SHALL BE KNOWLEDGEABLE OF THE PROJECT AND SHALL BE THE SPECIFIC PERSONS INTENDED TO CONTINUE WITH THE PROJECT THROUGH TO COMPLETION. IF REQUIRED, REVISED PLANS WILL BE ISSUED THROUGH OFFICIAL CHANNELS. CHANGES IN THE BID PRICE WILL BE DISCUSSED, BUT NO CHANGE ORDERS WILL BE ISSUED UNLESS PROCESSED THOUGH OFFICIAL CHANNELS. IT SHALL BE UNDERSTOOD THAT THE ENGINEER HAS NO AUTHORITY TO ISSUE CHANGE ORDERS. THE FOLLOWING TRADES SHALL BE REPRESENTED FOR THE MINIMUM TIME INDICATED: MECHANICAL SHEET METAL 4 HOURS PLUMBING/PIPING 4 HOURS ELECTRICAL 4 HOURS SPRINKLER 2 HOURS GENERAL CONTRACTOR ALL SESSIONS DRAWINGS ARE DIAGRAMMATIC, SHOWING THE GENERAL LOCATION, TYPE, LAYOUT, AND EQUIPMENT REQUIRED. THE DRAWINGS SHALL NOT BE SCALED FOR EXACT MEASUREMENT. REFER TO ARCHITECTURAL DRAWINGS FOR DIMENSIONS. REFER TO MANUFACTURER'S STANDARD INSTALLATION DRAWINGS FOR EQUIPMENT CONNECTIONS AND INSTALLATION REQUIREMENTS. PROVIDE DUCTWORK, CONNECTIONS, ACCESSORIES, OFFSETS, AND MATERIALS NECESSARY FOR A COMPLETE SYSTEM. DRAWING INDEX DDECRIPTIN V v FiRc DESIGN WORLDWIDE 311 Elm Street Suite 600 Cincinnati, OH 45202 www.FRCH.com 513 241 3000 INCLUDED IN SET 85% REVIEW SET 6/13/16 Owner 804.727.1757 Apple Hospitality REIT, Inc. 814 East Main Street Richmond, VA 23219 Chris Zeigler Architect 513.241.3000 PO.000v LEGEND, GENERAL NO ES, DRAWING INDEX X Mike Keitling Interior Design 513.241.3000 FRCH Design Worldwide 1: 513.241.5015 311 Elm Street, Suite 600 Cincinnati, OH 45202-2706 Raejean Downs ISSUED INFORMATION P0.01 SCHEDULES, CALCULATIONS X 07.29.2016 REVISIONS: D,p170Cip00 •o° , .... Ooo /sOooa .. ° � � . o15 o`er $.Zo r • ' •0;..• ...• `.$ 9,16 RoBIsoN ENGINEERING, INC 19401 40TH AVE w, SUITE 302 P1.0 LEVEL 1 PLUMBING PLAN X INTERIOR & EXTERIOR RENOVATION Homewood Suites Tukwila 6955 Fort Dent Way Tukwila, WA 98188-2554 PROJECT NUMBER: 032609.000 SHEET INFORMATION LEGEND, GENERAL NOTES, INDEX. EIVEU DRAWN BY: BK, CITY OF T U K W I I_ L REVIEWED BY: RR AUG 2 3 2016 SCALE: VARIES PERMIT CCNU ILA AUTHORIZED FOR: PERMIT REVIEW P2.0 bETAILS X 039 AIL SEPARATE PERMIT AND APPROVAL REQUIRED 7 8 9 10 11 12 13 14 HOMEWOOD ... SUITES BY HILTON"' Seattle/Tukwila., WA Inn Code: SEATK FiRc DESIGN WORLDWIDE 311 Elm Street Suite 600 Cincinnati, OH 45202 www.FRCH.com 513 241 3000 Owner 804.727.1757 Apple Hospitality REIT, Inc. 814 East Main Street Richmond, VA 23219 Chris Zeigler Architect 513.241.3000 FRCH Design Worldwide f: 513.241.5015 311 Elm Street, Suite 600 Cincinnati, OH 45202-2706 Mike Keitling Interior Design 513.241.3000 FRCH Design Worldwide 1: 513.241.5015 311 Elm Street, Suite 600 Cincinnati, OH 45202-2706 Raejean Downs ISSUED INFORMATION OWNER REVIEW SET: BRAND REVIEW SET: ISSUED: 07.29.2016 REVISIONS: D,p170Cip00 •o° , .... Ooo /sOooa .. ° � � . o15 o`er $.Zo r • ' •0;..• ...• `.$ 9,16 RoBIsoN ENGINEERING, INC 19401 40TH AVE w, SUITE 302 LYNNWOOD, WA 98036 206-364-3343 TEL / 425-836-0098 FAx PROJECT INFORMATION INTERIOR & EXTERIOR RENOVATION Homewood Suites Tukwila 6955 Fort Dent Way Tukwila, WA 98188-2554 PROJECT NUMBER: 032609.000 SHEET INFORMATION LEGEND, GENERAL NOTES, INDEX. EIVEU DRAWN BY: BK, CITY OF T U K W I I_ L REVIEWED BY: RR AUG 2 3 2016 SCALE: VARIES PERMIT CCNU ILA AUTHORIZED FOR: PERMIT REVIEW 02016 This drawing, printed or otherwise, is the copyrighted property of FRCH Design Worldwide and FRCH/Architecture, Inc., P.C. The drawing may not be used, reproduced or copied without the permission of FRCH Design Worldwide or FRCH/Architecture, Inc., P.0 4 5 6 7 8 9 10 11 12 13 14 Plumbing Fixture Schedule (1) PLAN MARK ROOM ROGATION SERVICE SIZE — INCHES FLOW RATES FIXTURE TYPE FINISH BASIS OF DESIGN MODEL NOTES CW HW W V SK -1 BREAKROOM KITCHEN h h 2 1-1/2 PROJECT INFORMATION 2—COMP SINK STAINLESS SHEET INFORMATION TOP MOUNT DRAWN BY: BK, AS AUG 2 3 2016 REVIEWED BY: RRPERMIT CENTER SCALE: VARIES AUTHORIZED FOR: PERMIT REVIEW 1.5 GPM FAUCET CHROME ONE HOLE MOUNT NOTES: (1) CONTRACTOR SHALL CONFIRM MAKE. MODEL, AND FINISH OF ALL FIXTURES WITH OWNER AND ARCHITECT PRIOR TO ORDERING. (2) SIZE PER PLANS AL PIPE SUPPORTS PIPE SUPPORTS ALL SUSPENDED REFRIGERANT PIPING SHALL BE SUPPORTED AS FOLLOWS: MATERIAL MAX. HORIZONTAL SPACING MAX. VERTICAL SPACING COPPER TUBING <1Y4" 6 FT. 10 FT. COPPER TUBING z1) " 10 FT. 10 FT. ALL SUSPENDED WATER SUPPLY PIPE SHALL BE SUPPORTED AS FOLLOWS: MATERIAL MAX. HORIZONTAL SPACING MAX. VERTICAL SPACING COPPER PIPE 12 FT. 10 FT. COPPER TUBING<1Y4" 6 FT. 10 FT. COPPER TUBING >11Z" 10 FT. 10 FT. CPVC <1" 3 FT. 10 FT. CPVC .1)'4" 4 FT. 10 FT. ALL SUSPENDED SANITARY AND VENT PIPE SHALL BE SUPPORTED AS FOLLOWS: MATERIAL MAX. HORIZ. SPACING MAX. VERT. SPACING ABS 4 FT. 10 FT. PVC (TYPE DWV) 4 FT. 10 FT. CAST—IRON <10 FT. PIPE SECTIONS) 5 FT. 15 FT. CAST—IRON 10 FT. PIPE SECTIONS) 10 FT. 15 FT. FIXTURE FLOW RATES APPLICABLE CODES MAXIMUM FIXTURE FLOW RATES(1) FIXTURE FLOW RATE SHOWERHEADS ISSUED INFORMATION ,2.5 GPM LAVATORIES — RESIDENTIAL ISSUED: 07.29.2016 2.2 GPM LAVATORIES — NONRESIDENTIAL 0.5 GPM METERING FAUCETS 0.25 GAL/CYCLE KITCHEN FAUCETS 2.2 GPM WATER CLOSETS PROJECT INFORMATION 1.6 GAL/FLUSH URINALS SHEET INFORMATION 1.0 GAL/FLUSH NOTES: (1) FLOW RATES PER 2012 UPC TABLE L 801.2(1 Al 2012 INTERNATIONAL BUILDING CODE (I80 2012 INTERNATIONAL MECHANICAL CODE (IMC) 2012 UNIFORM PLUMBING CODE (UPC) 2012 WASHINGTON STATE ENERGY CODE (WSEC) PIPE MATERIALS Ak PIPE MATERIALS 1. UNDERGROUND SERVICE ENTRANCE PIPING: STAINLESS STEEL 2. ABOVEGROUND WATER DISTRIBUTION PIPING: 3" AND LARGER:STAINLESS STEEL 2jf" AND SMALLER: COPPER. TYPE L. GUESTROOMS: PEX 3. UNDERGROUND WASTE & VENT PIPING: PVC. 4. ABOVEGROUND WASTE PIPING: OCCUPIED FLOORS (B1 AND ABOVE): NO—HUB CAST IRON UNOCCUPIED FLOORS (P1 & P2): ABS 5. ABOVEGROUND VENT PIPING: ABS. 6. ABOVEGROUND GAS PIPING: STEEL PIPE, ASTM A 53; TYPE E OR S. 7. UNDERGROUND GAS PIPING: POLYETHYLENE, ASTM D-2513. 8. CONDENSATE DRAIN PIPING: COPPER, TYPE M. 9. UNDERGROUND STORM PIPING: PVC. 10. ABOVEGROUND STORM PIPING: NO—HUB CAST IRON. NOTE: ALL METAWC PIPE, FITTINGS AND PARTS OF FIXTURES BURIED IN THE GROUND SHALL BE PROTECTED BY AT LEAST 40 MILS PLASTIC SLEEVE OR EQUIVALENT WRAPPING. FERROUS PIPING IS PROHIBITED UNDERGROUND. ppb 04130 SEPARATE PERMIT AND APPROVAL REQUIRED AL 9 10 11 12 13 14 .` .HOMEWOOD ", SUITES BY HILTON" Seattle/Tukwila, WA Inn Code: SEATK F RC DESIGN WORLDWIDE 311 Elm Street Suite 600 Cincinnati, OH 45202 www.FRCH.com 513 241 3000 Owner 804.727.1757 Apple Hospitality REIT, Inc. 814 East Main Street Richmond, VA 23219 Chris Zeigler Architect 513.241.3000 FRCH Design Worldwide f: 513.241.5015 311 Elm Street, Suite 600 Cincinnati, OH 45202-2706 Mike Keifling Interior Design 513.241.3000 FRCH Design Worldwide f: 513.241.5015 311 Elm Street, Suite 600 Cincinnati, OH 45202-2706 Raejean Downs ISSUED INFORMATION OWNER REVIEW SET: BRAND REVIEW SET: ISSUED: 07.29.2016 REVISIONS: ,,DODDOO .0° ' ,..RO,g°°o Ci 4. h: • °� / %40Oo© Dc Z.ZC] t30 .; Jim i.., �4 - 6 1 000� / L _s00NI DOoo[]0© RoBisoN ENGINEERING, INC 19401 40TH AvE W, SUITE 302 LYNNWOOD, WA 98036 206-364-3343 TEL / 425-835-0098 FAX PROJECT INFORMATION INTERIOR & EXTERIOR RENOVATION . Homewood Suites Tukwila 6955 Fort Dent Way Tukwila, WA 98188-2554 PROJECT NUMBER: 032609.000 SHEET INFORMATION SCHEDULE, PROJECT NOTES RECEIVED ('ITV OF TUKWIL, DRAWN BY: BK, AS AUG 2 3 2016 REVIEWED BY: RRPERMIT CENTER SCALE: VARIES AUTHORIZED FOR: PERMIT REVIEW 10 EXISTING WASTE LINE FROM KITCHEN TO SEWER 1X" VENT TO ROOF (2 FU) 3"WASTE (2 FU) ESTIMATED POINT OF CONNECTION TO EXISTING SEWER LINE SEWER LINE CONSTRUCTION NOTES: 3" SEWER LINE SHOWN FOR PRICING PURPOSES ONLY. EXACT ROUTING OF SEWER LINES SHALL BE DETERMINED BY THE FOLLOWING DIRECTIONS BELOW. 1. PLUMBING CONTRACTORS SHALL JET AND LOCATE THE SANITARY SEWER LINE BETWEEN THE KITCHEN AND THE MAIN SEWER LINE IN THE DRIVEWAY. 2. PLUMBING CONTRACTOR SHALL REPORT FINDINGS TO PLUMBING ENGINEER (ROBISON ENGINEERING) AND COORDINATE BEST ROUTING FOR NEW SEWER LINE FOR KITCHEN SINK IN THE EMPLOYEE BREAKROOM. WASTE PLUMBING PLAN SCALE: 1' = 1'-0" P1-0 w • a ® • s 1 2 3 4 5 6 7 8 9 10 ) "CW(2FU) Y2"HW(2FU) 11 CONNECT CW & HW TO EXISTING KITCHEN PLUMBING (CONNECT TO MIN 3'4") ROUTE IN CEILING 12 13 14 SK -1 SUPPLY. PLUMBING PLAN bWoz9 SCALE: 1' = 1'-0" 2 SEPARATE PERMIT AND APPROVAL REQUIRED 11 12 13 14 HOMEWOOD SITES BY HILTON' Seattle/Tukwila, WA Inn Code: SEATK F RC H DESIGN WORLDWIDE 311 Elm Street Suite 600 Cincinnati, OH 45202 www.FRCH.com 513 241 3000 Owner 804.727.1757 Apple Hospitality REIT, Inc. 814 East Main Street Richmond, VA 23219 Chris Zeigler Architect 513.241.3000 FRCH Design Worldwide f: 513.241.5015 311 Elm Street, Suite 600 Cincinnati, OH 45202-2706 Mike Keifling Interior Design 513.241.3000 FRCH Design Worldwide f: 513.241.5015 311 Elm Street, Suite 600 Cincinnati, OH 45202-2706 Raejean Downs ISSUED INFORMATION OWNER REVIEW SET: BRAND REVIEW SET: ISSUED: 07.29.2016 REVISIONS: ooa❑❑oo .0° , -,..ROe° oo F '!so %-z?, ❑ d_ ❑ o 000 �....." > o- X29.-1 ociannoo- IC) ENGINEERING, INC 19401 40TH AVE W, SUITE 302 LYNNWOOD, WA 98036 206-364-3343 TEL / 425-835-0098 FAX PROJECT INFORMATION INTERIOR & EXTERIOR RENOVATION Homewood Suites Tukwila 6955 Fort Dent Way Tukwila, WA 98188-2554 PROJECT NUMBER: 032609.000 SHEET INFORMATION LEVEL 1 PLUMBING PLAN RECEIVED CITY OF TUKWILA DRAWN BY: BK, AS AUG 2 3 2016 REVIEWED BY: RR PERMIT CENTER SCALE: VARIES AUTHORIZED FOR: PERMIT REVIEW 3 4 6 7 8 9 CONCRETE SLAB /1 d PIPE SLAB PENETRATION DETAIL COPPER PIPE FERNCO COUPLING OR ELECTRICIAN'S DUCTSEAL PVC PIPE A A . DA • SCALE: NONE \P2-0 10 11 12 v v v EXCAVATED TRENCH 13 f FINAL BACKFILL INITIAL BACKFILL (6" MIN. ABOVE PIPE) HAUNCHING BEDDING (4"-6") OR UNDISTURBED NATIVE SOIL TRENCH CONSTRUCTION AND BACKFILL MATERIALS SHALL BE IN ACCORDANCE WITH ASTM D2321. LOCAL MATERIALS ARE ACCEPTABLE FOR BACKFILL AS ALLOWED BY ASTM D2321. BEDDING SHALL BE COMPACTED BEFORE PIPE IS INSTALLED. HAUNCHING SHALL COMPACTED BEFORE BACKFILL IS INSTALLED. BACKFILL SHALL BE INSTALLED AND COMPACTED IN 6" LAYERS. PLASTIC PIPE TRENCH DETAIL SCALE: NONE 14 A. w s a a w s 7 8 9 10 11 12 13 14 �.39 SEPARATE PERMIT AND APPROVAL REQUIRED HOMEWOOD SUITES BY HILTON- Seattie/Tukwila, WA Inn Code: SEATK FRC DESIGN WORLDWIDE 311 Elm Street Suite 600 Cincinnati, OH 45202 www.FRCH.com 513 241 3000 Owner 804.727.1757 Apple Hospitality REIT, Inc. 814 East Main Street Richmond, VA 23219 Chris Zeigler Architect 513.241.3000 FRCH Design Worldwide f: 513,241.5015 311 Elm Street, Suite 600 Cincinnati, OH 45202-2706 Mike Keifling Interior Design 513.241.3000 FRCH Design Worldwide f: 513.241.5015 311 Elm Street, Suite 600 Cincinnati, OH 45202-2706 Raejean Downs ISSUED INFORMATION OWNER REVIEW SET: BRAND REVIEW SET: ISSUED: 07.29.2016 REVISIONS: 000aoa000 .o°'`.Ro%1/4S. 00CI BZ 511% -ii 4 1-121 r '•' . ' -'� 16 0000%,.,%/int. --Oonnos- ROBISON ENGINEERING, INC 19401 40TH AVE W, SUITE 302 LYNNWOOD, WA 98036 206-364-3343 TEL / 425-835-0098 FAX PROJECT INFORMATION INTERIOR & EXTERIOR RENOVATION Homewood Suites Tukwila 6955 Fort Dent Way Tukwila, WA 98188-2554 PROJECT NUMBER: 032609.000 SHEET INFORMATION DETAILS RECEIVED DRAWN BY: BK, ACI 'Y OF I UKWIL� AUG 2 3 2016 REVIEWED BY: RR SCALE: VARIES PERMIT CENTER AUTHORIZED FOR: PERMIT REVIEW