Loading...
HomeMy WebLinkAboutPermit D16-0239 - ANDRADE RESIDENCE - NEW SINGLE FAMILY RESIDENCEANDRADE RESIDENCE 13616 MILITARY RD S D16-0239 Parcel No: Address: Project Name: City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-438-9350 Web site: http://www.TukwilaWA.gov 1623049416 13616 MILITARY RD S ANDRADE RESIDENCE COMBOSFR PERMIT Permit Number: D16-0239 Issue Date: 8/24/2016 Permit Expires On: 2/20/2017 Owner: Name: Address: Contact Person: Name: Address: Contractor: Name: Address: License No: Lender: Name: Address: A&E HOMES LLC PO BOX 6362 , KENT, WA, 98064 JOSE GARCIA 27440 141ST AVE SE , KENT, WA, 98042 NEW HORIZON CONSTRUCTION LLC 27440 141ST AVE SE , KENT, WA, 98042 NEWHOHC984NB MIGUEL ANDRADE 13616 MILITARY RD , TUKWILA, WA, 98030 Phone: (425) 213-6688 Phone: Expiration Date: DESCRIPTION OF WORK: NEW PERMIT FOR EXPIRED COMBOSFR D14-0306. FINAL INSPECTIONS ONLY Project Valuation: $0.00 Type of Fire Protection: Sprinklers: Fire Alarm: Type of Construction: Electrical Service Provided by: TUKWILA Fees Collected: $137.50 Occupancy per IBC: Water District: 125 Sewer District: NONE Current Codes adopted by the City of Tukwila: International Building Code Edition: International Residential Code Edition: International Mechanical Code Edition: Uniform Plumbing Code Edition: International Fuel Gas Code: 2015 2015 2015 2015 2015 National Electrical Code: WA Cities Electrical Code: WAC 296-46B: WA State Energy Code: 2014 2014 2014 2015 Public Works Activities: Channelization/Striping: Curb Cut/Access/Sidewalk: Fire Loop Hydrant: Flood Control Zone: Hauling/Oversize Load: Land Altering: Landscape Irrigation: Sanitary Side Sewer: Sewer Main Extension: Storm Drainage: Street Use: Water Main Extension: Water Meter: Volumes: Cut: 0 Fill: 0 Number: 0 No Permit Center Authorized Signature: Date: I hearby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this development permit aand��agr-e to the conditions attached to this permit. Signature: i/ )n Print Name: cp S e Cel/Y(0 CJ. Date: Z`�1/F This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: ***BUILDING PERMIT CONDITIONS*** 2: Work shall be installed in accordance with the approved construction documents, and any changes made during construction that are not in accordance with the approved construction documents shall be resubmitted for approval. 3: All permits, inspection record card and approved construction documents shall be kept at the site of work and shall be open to inspection by the Building Inspector until final inspection approval is granted. 4: The special inspections and verifications for concrete construction shall be as required by IBC Chapter 17, Table 1705.3. 5: The special inspections for steel elements of buildings and structures shall be required. All welding shall be done by a Washington Association of Building Official Certified welder. 6: Installation of high-strength bolts shall be periodically inspected in accordance with AISC specifications. 7: The special inspection of bolts to be installed in concrete prior to and during placement of concrete. 8: When special inspection is required, either the owner or the registered design professional in responsible charge, shall employ a special inspection agency and notify the Building Official of the appointment prior to the first building inspection. The special inspector shall furnish inspection reports to the Building Official in a timely manner. 9: A final report documenting required special inspections and correction of any discrepancies noted in the inspections shall be submitted to the Building Official. The final inspection report shall be prepared by the approved special inspection agency and shall be submitted to the Building Official prior to and as a condition of final inspection approval. 10: New suspended ceiling grid and light fixture installations shall meet the seismic design requirements for nonstructural components. ASCE 7, Chapter 13. 11: Partition walls shall not be tied to a suspended ceiling grid. All partitions greater than 6 feet in height shall be laterially braced to the building structure. Such bracing shall be independent of any ceiling splay bracing. 12: Readily accessible access to roof mounted equipment is required. 13: Truss shop drawings shall be provided with the shipment of trusses delivered to the job site. Truss shop drawings shall bear the seal and signature of a Washington State Professional Engineer. Shop drawings shall be maintained on the site and available to the building inspector for inspection purposes. 14: Insulating materials, where exposed as installed in buildings of any type of construction, shall have a flame spread index of not more than 25 and a smoke development index of not more than 450. Where facings are installed in concealed spaces in buildings of Type III, IV, or V construction, the flame spread and smoke- developed limitations do not apply to facings, that are installed behind and in substantial contact with the unexposed surface of the ceiling, wall or floor finish. 15: Subgrade preparation including drainage, excavation, compaction, and fill requirements shall conform strictly with the recommendations given in the soils report. Special inspection is required. 16: All construction shall be done in conformance with the Washington State Building Code and the Washington State Energy Code. 17: Structrual Observations in accordance with I.B.C. Section 1709 is required. At the conclusion of the work included in the permit, the structural observer shall submit to the Building Official a written statement that the site visits have been made and identify any reported deficiencies which, to the best of the structural observer's knowledge, have not been resolved. 18: AH food preparation establishments must have Seattle/King County Department of Public Health sign -off prior to opening or doing any food processing. Arrangements for final Health Department inspection shall be made by calling Seattle/King County Department of Public Health, (1-800-325-6165 ext 9-566), at least three working days prior to desired inspection date. On work requiring Health Department approval, it is the contractor's responsibility to have a set of plans approved by the agency on the job site. 19: Fire retardant treated wood shall have a flame spread of not greater than 25. All materials shall bear identification showing the fire performance rating thereof. Such identification shall be issued by an approved agency having a service for inspection at the factory. 20: Notify the City of Tukwila Building Division prior to placing any concrete. This procedure is in addition to any requirements for special inspection. 21: Special inspection for sprayed fire-resistant materials applied to structural elements and decks is required. Special inspections shall be based on the fire-resistance design as designated in the approved construction documents. 22: All wood to remain in placed concrete shall be treated wood. 23: Masonry construction shall be special inspected. 24: All rack storage requires a separate permit issued through the City of Tukwila Permit Center. Rack storage over 8-feet in height shall be anchored or braced to prevent overturning or displacement during seismic events. The design and calculations for the anchorage or bracing shall be prepared by a registered professional engineer licensed in the State of Washington. Periodic special inspection is required during anchorage of storage racks 8 feet or greater in height. 25: There shall be no occupancy of a building until final inspection has been completed and approved by Tukwila building inspector. No exception. 26: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of this requirement. 27: A Certificate of Occupancy shall be issued for this building upon final inspection approval by Tukwila building inspector. 28: All construction noise to be in compliance with Chapter 8.22 of the City of Tukwila Municipal Code. A copy can be obtained at City Hall in the office of the City Clerk. 29: Every occupied space other than enclosed parking garages and buildings used for repair of automobiles shall be ventilated in accordance with the applicable provisions of the International Mechanical Code. 30: Water heaters shall be anchored or strapped to resist horizontal displacement due to earthquake motion. Strapping shall be at points within the upper one-third and lower one-third of the water heater's vertical dimension. A minimum distance of 4 -inches shall be maintained above the controls with the strapping. 31: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206-431-3670). 32: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center. 33: Preparation before concrete placement: Water shall be removed from place of deposit before concrete is placed unless a tremie is to be used or unless otherwise permitted by the building official. All debris and ice shall be removed from spaces to be occupied by concrete. 34: Prior to final inspection for this building permit, a copy of the roof membrane manufacturer's warranty certificate shall be provided to the building inspector. 35: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 36: ***MECHANICAL PERMIT CONDITIONS*** 37: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431-3670). 38: All permits, inspection record card and approved construction documents shall be kept at the site of work and shall be open to inspection by the Building Inspector until final inspection approval is granted. 39: Manufacturers installation instructions shall be available on the job site at the time of inspection. 40: Except for direct -vent appliances that obtain all combustion air directly from the outdoors; fuel -fired appliances shall not be located in, or obtain combustion air from, any of the following rooms or spaces: Sleeping rooms, bathrooms, toilet rooms, storage closets, surgical rooms. 41: Equipment and appliances having an ignition source and located in hazardous locations and public garages, PRIVATE GARAGES, repair garages, automotive motor -fuel dispensing facilities and parking garages shall be elevated such that the source of ignition is not less than 18 inches above the floor surface on which the equipment or appliance rests. 42: Type 1 Hoods, the required grease duct leakage test and (light test shall be performed by a special inspection and testing agency in accordance with I.M.C. Chapter 5. 43: ***PLUMBING/GAS PIPING PERMIT CONDITIONS*** 44: No changes shall be made to applicable plans and specifications unless prior approval is obtained from the Tukwila Building Division. 45: All permits, inspection records and applicable plans shall be maintained at the job and available to the plumbing inspector. 46: All plumbing and gas piping systems shall be installed in compliance with the Uniform Plumbing Code and the Fuel Gas Code. 47: No portion of any plumbing system or gas piping shall be concealed until inspected and approved. 48: All plumbing and gas piping systems shall be tested and approved as required by the Plumbing Code and Fuel Gas Code. Tests shall be conducted in the presence of the Plumbing Inspector. It shall be the duty of the holder of the permit to make sure that the work will stand the test prescribed before giving notification that the work is ready for inspection. 49: No water, soil, or waste pipe shall be installed or permitted outside of a building or in an exterior wall unless, adequate provision is made to protect such pipe from freezing. All hot and cold water pipes installed outside the conditioned space shall be insulated to minimum R-3. 50: Plastic and copper piping running through framing members to within one (1) inch of the exposed framing shall be protected by steel nail plates not less than 18 guage. 51: Piping through concrete or masonry walls shall not be subject to any load from building construction. No plumbing piping shall be directly embedded in concrete or masonry. 52: All pipes penetrating floor/ceiling assemblies and fire -resistance rated walls or partitions shall be protected in accordance with the requirements of the building code. 53: Piping in the ground shall be laid on a firm bed for its entire length. Trenches shall be backfilled in thin layers to twelve inches above the top of the piping with clean earth, which shall not contain stones, boulders, cinderfill, frozen earth, or construction debris. 54: The issuance of a permit or approval of plans and specifications shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the Plumbing Code or Fuel Gas Code or any other ordinance of the jurisdiction. 55: The applicant agrees that he or she will hire a licensed plumber to perform the work outlined in this permit. 56: All new plumbing fixtures installed in new construction and all remodeling involving replacement of plumbing fixtures in all residential, hotel, motel, school, industrial, commercial use or other occupancies that use significant quantities of water shall comply with Washington States Water Efficiency ad Conservation Standards in accordance with RCW 19.27.170 and the 2006 Uniform Plumbing Code Section 402 of Washington State Amendments 57: ***ELECTRICAL PERMIT CONDITIONS*** 58: A copy of the electrical work permit shall be posted or otherwise made readily accessible to the Electrical Inspector at each work site. 59: Approved plans shall be maintained at the construction site and shall be readily available to the Electrical Inspector. 60: All electrical work shall be in accordance with NFPA 70 - NEC, and requirements for electrical installations, Chapter 296-46B WAC. 61: When any portion of the electrical installation is to be hidden from view by permanent placement of parts of the building, such equipment shall not be concealed until it has been inspected and approved by the Electrical Inspector. 62: The issuance of an electrical work permit shall not be construed to be a permit for, or an approval of, any violation of the provisions of the electrical code or other ordinances of the jurisdiction. Permits or related documentation that presumes to grant this authority are therefore not valid. 63: Any change in the scope of work described by the electrical work permit shall require additional work permits. Where approved plans have been issued, revisions to the plans and additional review may be required. 64: Prior to permit issuance for new structure, the demolition permit must receive final inspection approval. PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 1700 BUILDING FINAL** CITY OF TUKV A Community Development Department Public Works Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.TukwilaWA.gov Combination _ .;rmit No. f f -1 7 1 Project No.: Date Application Accepted: Date Application Expires: (For office use only) COMBINATION PERMIT APPLICATION — NEW SINGLE FAMILY Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **please print** SITE LOCATION Site Address: i 3 616 tot t I, I -a Ty c King Co Assessor's Tax No.: PROPERTY OWNER Name: Name: M 1`1.1S��LI 4 <'_ L (1 c Address: 211141 167 t.k {o( 56 -City: City: 1 State: Zip: l' -c.. t- cxr 4Q v► State: /A< let- Zip: Q Wo 3'O CONTACT PERSON — person receiving all project communication Name: Name: 5e Coirt;;c L (1 c Address: 27g160 ,' yiSF ?4cx- Sc City: 1 State: Zip: l' -c.. t- cxr 4Q o `'(2 Phone: Fax: '12-5 213 (‘ g ff Contr Reg No.: ‘Cb Z. 21- '? Exp Date: e % ;� / 7 Email: + (O5P1."ru1Ne Irl Ctma;1.rn►u GENERAL CONTRACTOR INFORMATION Name: Company Name:n I IMPut (-. t i tdA CO" 51, L (1 c Address: e7iiyo /yi5F %4 -Ur__ S.. City: State: Zip: City: Phone: Fax: '/25 CZR" 1331 Contr Reg No.: ‘Cb Z. 21- '? Exp Date: e % ;� / 7 Tukwila Business License No.: 00 06 .6 ARCHITECT OF RECORD Name: J7fA / 011147,6e, - Company Name: Address: Architect Name: City: State: Address: City: State: Zip: Phone: Fax: Email: ENGINEER OF RECORD Name: J7fA / 011147,6e, - Company Name: Address: Engineer Name: City: State: Address: City: State: Zip: Phone: Fax: Email: LENDER/BOND ISSUED (required for projects $5,000 of greater per RCW 19.27.095) Name: J7fA / 011147,6e, - Address: City: State: Zip: H:\Applications\Forms-Applications On Line \2011 Applications\Combination Permit Application Revised 8-9-11.docx Revised: August 2011 bh Page 1 of 4 PROJECT INFORMATION — Valuation of project (contractor's bid price): $ Scope of work (please provide detailed information): )149pcc t,erc. 01/11 y `12t -( --0506 DETAILED BUILDING INFORAMTION — PROJECT FLOOR AREAS PROPOSED SQUARE FOOTAGE Basement 15t floor 2"d floor Garage ■ carport ■ Deck — covered • uncovered • Total square footage Per City of Tukwila Ordinance No. 2327, all new single family homes are required to have an automatic fire sprinkler system installed in the home. Please contact the Tukwila Fire Department for more information - 206-575-4407. EQUIPMENT AND FIXTURES - INDICATE NUMBER OF EACH TYPE OF FIXTURE TO BE INSTALLED AS PART OF YOUR PROJECT. MECHANICAL: Value of mechanical work $ furnace <100k btu thermostat emergency generator fuel type: ❑ electric ❑ gas appliance vent ventilation fan connected to single duct wood/gas stove water heater (electric) other mechanical equipment PLUMBING: Value of plumbing/gas piping work $ bathtub (or bath/shower combo) bidet clothes washer dishwasher floor drain shower lavatory (bathroom sink) sink water closet water heater (gas) lawn sprinkler system gas piping outlets H:\Applications\rorms-Applications On Line\2011 Applications\Combination Permit Application Revised 8-9-1 I.docx Revised: August 2011 bh Page 2 of 4 r PUBLIC WORKS PERMIT INFORM, JON — Scope of work (please provide detailed information): Call before you Dig: 811 Please refer to Public Works Bulletin #1 for fees and estimate sheet. WATER DISTRICT ❑ .. Tukwila ❑ ...Water District #125 ❑ .. Letter of water availability provided SEWER DISTRICT ❑ .. Tukwila ❑ .. Sewer use certificate ❑... Highline ❑...Valley View ❑...Renton ❑ ...Letter of sewer availability provided ❑ .. Renton ❑ .. Seattle SEPTIC SYSTEM: ❑ .. On-site septic system — for on-site septic system, provide 2 copies of a current septic design approved by King County Health Department. SUBMITTED WITH APPLICATION (MARK BOXES WHICH APPLY): 111.. Civil Plans (Maximum Paper Size — 22" X 34") ❑ .. Technical information Report (Storm Drainage) ❑ .. Bond 0...Insurance ❑... Easement(s) ❑... Geotechnical Report 0...Maintenance Agreement(s) ❑ ...Hold Harmless — (SAO) ❑ ...Hold Harmless — (ROW) PROPOSED ACTIVITIES (MARK BOXES THAT APPLY): ❑ .. Right -Of -Way Use - Potential disturbance ❑...Construction/Excavation/Fill - Right -of -Way... ❑ -or- Non Right -of -Way.. ❑ ❑ .. Total Cut ❑ .. Total Fill ❑ .. Sanitary Side Sewer ❑ .. Cap or Remove Utilities 0 .. Frontage Improvements ❑ .. Traffic Control Cubic Yards Cubic Yards 0...Work In Flood Zone ❑... Storm Drainage 0...Abandon Septic Tank ❑ ..Trench Excavation 0... Curb Cut ❑ .. Utility Undergrounding 0...Pavement Cut ❑ ..Backflow Prevention - Fire Protection 0... Looped Fire Line Irrigation Domestic Water ❑ .. Permanent Water Meter Size " WO # 0 .. Residential Fire Meter Size WO # ❑ .. Deduct Water Meter Size 0 .. Temporary Water Meter Size " WO # ❑ .. Sewer Main Extension Public ❑ - or - Private ❑ ❑ .. Water Main Extension Public 0 - or - Private ❑ FINANCE INFORMATION — THIS INFORMATION IS REOUIRED TO BE FILLED OUT WHEN REQUESTING WATER OR SEWER SERVICE Fire line size at property line ❑ .. water ❑ .. sewer MONTHLY SERVICE BILLING TO: number of public fire hydrant(s) ❑ .. sewage treatment Name: Day Telephone: Mailing Address: City State Zip WATER METER REFUNDBILLING: Name: Day Telephone: Mailing Address: City State Zip H:\Applications\Forms-Applications On Line \201 I Applications \Combination Permit Application Revised 8-9-11 docx Revised: August 2011 bh Page 3 of 4 PERMIT APPLICATION NOTES —'. »LICABLE TO ALL PERMITS IN THIS 4 jl_,ICATION- Value of construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the permit center to comply with current fee schedules. Expiration of plan review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. 1 HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. PROPERTY OWNER I R U HORIZED AGENT: Signature: Print Name: i co5e Cniw Ctrl Mailing Address: 27L110 Mt" fl (1 c 5c Day Telephone: Date: 0 51z Lt /16 qz5 z r 3 City H:\Applications\Porms-Applications On Line\2011 Applications\Combination Permit Application Revised 8-9-1 I.docx Revised: August 2011 bh WW State 9gsoctr7 Zip Page 4 of 4 Cash Register Receipt City of Tukwila Receipt Number R9267 DESCRIPTIONS ACCOUNT QUANTITY PAID PermitTRAK $137.50 D16-0239 Address: 13616 MILITARY RD S Apn: 1623049416 $137.50 DEVELOPMENT $137.50 WASHINGTON STATE SURCHARGE PERMIT REINSPECT FEE - AFTER HRS INSP FEE TOTAL FEES PAID BY RECEIPT: R9267 B640.237.114 R000.359.000.00.01 0.00 0.00 $4.50 $133.00 $137.50 Date Paid: Wednesday, August 24, 2016 Paid By: JOSE GARCIA Pay Method: CREDIT CARD 360263 Printed: Wednesday, August 24, 2016 1:39 PM 1 of 1 CRSYSTEMS INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION (206) 431-3670 b/-c23gi 6300 Southcenter Blvd., #100, Tukwila. WA 98188 Permit Inspection Request Line (206) 438-9350 tkIN Project:/� �D -N.0 eat U%^ lit' Te of Inspection: �''' buJLL111.&t�J•4�.A. -2- Address: /SIG miLiptei ,i 5 Date Called: Special Instructions: Date Want d: / 2C//6 p: Reques r: Phone No: Approved per applicable codes. Corrections required prior to approval. COMMENTS: Inspector: /I , 11-1,4 Date/oho/1o' REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit biCsts023q PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Pro' ct: /-4AMP I E" J4 11X J« Ty of Inspection: 1&..11L-1)iAJ6 .✓.at_ Address: 136/6 pi i urillS/ a S Date Called: Date Wante / /& 2s//4 �a Special Instructions: m. Requeste : Phone No: ElApproved per applicable codes. Corrections required prior to approval. COMMENTS: I WtrSSiAJ( fa,Mkt4ifie beibit hiakes 2/)issiaf 649.44privnte l Ail, Ar' 3)14417sido Aetecs Cel,egAi) — 1 e <:,r-oi a° IP %.0S(41 Date: /®2_'j /6. REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. kgr. INSPECTION RECORD Retain a copy with permit 6 -Ong PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 Permit Inspection Request Line (206) 438-9350 (206) 431-3670 Project: AAJ MAW' ,� /� IDE, 6 Tye of Inj�'ection: GAS (4piAZ- i‹./.41.. Address: 16/c ) /tr tb $ Date Called: Special Instructions: Date Waned: i iop s-7 � a.m P.m. Reques er: Phone No: Approved per applicable codes. Corrections required prior to approval. COMMENTS: Inspector: Date:/0/05/7/6 REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit INS ION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION (206) 431-3670 �1G - oz 3q 6300 Southcenter Blvd., #100, Tukwila. WA 98188 Permit Inspection Request Line (206) 438-9350 \or Project: / AVA/16 IS -Si bL & Ty of Inspection: 60 1 tWAi&& f7if L Address: )36>6 l4 it T, e•/ l't S Date Called: Special Instructions: e� n4y- (✓s >omn� it rcSS i29V), '�r-- i) /�eQ�., q Date Wanted% Requester. Phone No: jJApproved per applicable codes. Corrections required prior to approval. COMMENTS: I LA—AID i stJ4, (2t rird -b A `' T1h'i'70 z tM 13>;1 r - i% i ' /41- .ba* 13t5A-vi p1A-Ait-ne ,4r sL, wAf• Dein- .61 e� n4y- (✓s >omn� it rcSS i29V), '�r-- i) /�eQ�., q //1-I ., �i2L'tr or ,1461.4. -e- qS m? ee 1 -off" '41 O A Ce-/r4- /� ' ° ele q >�f calf -A 7U ,4r— 't° t 1-t u a, - e '; SgAt ALL- (- r oxf 1 aura ei 1K 7) 5 t, /17J, P X724 %J &14 - , viis /'2-- I o%,o-u, 41 InspectorA bAhm Date (/7/ d./7//. REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. ii4eiddraJNPLOre OCT— INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 71G -O2 Project: . libi2Abc acitaiste Type of Inspection: 64S PIIPIAJ6 r c_ Address: 13(,14 wiiL) 2`i )2b S Date Called: Special Instructions: Date Want d: /0 2I/JG a.m. Request r: Phone No: ElApproved per applicable codes. F'4 Corrections required prior to approval. COMMENTS: Inspector: Atofki REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION RECORD WO:2°A Retain a copy with permit INS TION NO. J 9 - o239 PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 5outhcenter Blvd., #100, Tukwila. WA 98188 Permit Inspection Request Line (206) 438-9350 (206) 431-3670 Project: t2 b' 726-S i bEAicee7 Type of Inspection: mektAA 1 C4L /A/AL Address: 136)6 114/1-11;VN 0 3 Date Called: Special Instructions: Date Wanteda.m. le' Requeste : Phone No: 0 Approved per applicable codes. ElCorrections required prior to approval. COMMENTS: Inspector: Att-‘ Dater 2e REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. INSPECTION NO. INSPECTION RECORD Retain a copy with permit CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 bi6 -02,3q PERMIT NO. Project: Alibi/Abe' 0,-sebe' Type of Inspection: ,� (,mss Pi f 1Afr ,KAitiL. Address: 13616 Miar7r2y S Date Called: Special Instructions: Date Wante�• :......n.a. A /%/06 p.m. Request Phone No: Approved per applicable codes. ECorrections required prior to approval. COMMENTS: IN! t SS, AJ - c -A r T12 P A-r'eyiloNeW (; 2) I -web ,l/PE ,- 616- ewe Inspector:., // ^_ Atri Date:/0/4 n REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit INS ION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION (206) 431-3670 6300 Southcenter Blvd., #100, Tukwila. WA 98188 Permit Inspection Request Line (206) 438-9350 Project:n Aljb .A E )e.eSib&kke Type of Inspection: KrbA21 A-16 - Address: 1361 M'L Vw'/ 12b S Date Called: Special Instructions: Date Wanted /0 /1/A ,gym. Requester. Phone No: 1►:/ Approved per applicable codes. U Corrections required prior to approval. COMMENTS: Inspector: Date: /0/7//c., REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project: ,1b(l b 12 s1bfC Typ of Inspection: R14113I'J6- ski. Address:,Date I -"Zi � ri1Lrovit( 12i . Called: Special Instructions: Date Wanted:/ ��/ m. p.m. Requester: Phone No: NApproved per applicable codes. LJ Corrections required prior to approval. COMMENTS: Awl Date: e %6,, REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION -CZ ? 6300 Southcenter Blvd., #100, Tukwila. WA 98188 Permit Inspection Request Line (206) 438-9350 (206) 431-3670 Project: Allbe�Abe )2G3t IJEi 'a- Ty.Re of Inspection: f -L('ni 3i,Jc ,�, h,d4 Address: /36/6 /1/1 /1)70(4 i2 s Date Called: Special Instructions: Date- Wanted'' /0 Sp6 ��� C�. . p.m. Requester( Phone No: EApproved per applicable codes. Corrections required prior to approval. COMMENTS: lUST .Abb2m / Aro A-ccos roi Ars- Inspector:d,/ ,6744 Date: n REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. NEW HORIZON CONSTRUCTION TLC Home Espanol Contact Safety & Health Claims & Insurance 0 Washington State Department of Labor & Industries Page 1 of 2 Search L&I A -Z Index Help My L&I Workplace Rights Trades & Licensing NEW HORIZON CONSTRUCTION LLC Owner or tradesperson Principals GARCIA GONZALEZ, JOSE E, PARTNER/MEMBER GARCIA GONZALEZ, SARAI, PARTNER/MEMBER GARCIA GONZALEZ, VICTOR HUGO, PARTNER/MEMBER (End: 07/20/2016) Doing business as NEW HORIZON CONSTRUCTION LLC WA UBI No. 603 222 437 27440 141ST AVE SE KENT, WA 98042 425-213-6688 KING County Business type Limited Liability Company Governing persons JOSE E GARCIA-GONZALEZ VICTOR HUGO GARCIA-GONZALEZ; License Verify the contractor's active registration / license / certification (depending on trade) and any past violations. Construction Contractor Active. ........................................................ _............... Meets current requirements. License specialties GENERAL License no. NEWHOHC884NB Effective — expiration 08/02/2012— 08/27/2018 Bond ................. Wesco Insurance Co Bond account no. 46WB065412 $12,000.00 Received by L&I Effective date 01/12/2016 07/26/2015 Expiration date Until Canceled Bond history Insurance .............................. Arch Specialty Ins Co Policy no. AGL0016458-02 Received by L&I $1,000,000.00 Effective date https://secure.lni.wa.gov/verify/Detail.aspx?UBI=603222437&LIC=NEWHOHC884NB&SAW= 8/24/2016