Loading...
HomeMy WebLinkAboutPermit D16-0248 - AT&T - TENANT IMPROVEMENTAT&T MOBILE 344 SOUTHCENTER MALL EXPIRED 03/14/1 7 D16-0248 Parcel No: Address: City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-438-9350 Web site: http://www.TukwilaWA.gov DEVELOPMENT PERMIT 9202470010 344 SOUTHCENTER MALL Project Name: AT & T Permit Number: 016-0248 Issue Date: 9/15/2016 Permit Expires On: 3/14/2017 Owner: Name: Address: Contact Person: Name: Address: Contractor: Name: Address: License No: Lender: Name: Address: WESTFIELD PROPERTY TAX DEPT PO BOX 130940 , CARLSBAD, WA, 92013 AARON FRIEDT 13430 NE 177TH PL, WOODINVILLE, WA, 98072 PIONEER COMMUNICATIONS GP LLC PO BOX 569 , WOODINVILLE, WA, 98072 PIONECG903BQ AT & T 344 SOUTHCENTER MALL, TUKWILA, WA, 98188 Phone: (206) 755-7955 Phone: (425) 481-5500 Expiration Date: 1/13/2018 DESCRIPTION OF WORK: TENANT IMPROVEMENT- INSTALLING CABINETRY FOR RADIO TRANSMISSION EQUIPMENT TO SUPPLEMENT COVERAGE WITHIN SOUTHCENTER MALL. Project Valuation: $20,000.00 Type of Fire Protection: Sprinklers: Fire Alarm: Type of Construction: VB Electrical Service Provided by: TUKWILA Fees Collected: $824.42 Occupancy per IBC: M Water District: TUKWILA Sewer District: TUKWILA Current Codes adopted by the City of Tukwila: International Building Code Edition: International Residential Code Edition: International Mechanical Code Edition: Uniform Plumbing Code Edition: International Fuel Gas Code: 2015 2015 2015 2015 2015 National Electrical Code: WA Cities Electrical Code: WAC 296-46B: WA State Energy Code: 2014 2014 2014 2015 Public Works Activities: Channelization/Striping: Curb Cut/Access/Sidewalk: Fire Loop Hydrant: Flood Control Zone: Hauling/Oversize Load: Land Altering: Landscape Irrigation: Sanitary Side Sewer: Sewer Main Extension: Storm Drainage: Street Use: Water Main Extension: Water Meter: Volumes: Cut: 0 Fill: 0 Number: 0 No Permit Center Authorized Signature: Date: q(g-'fr0 I hearby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this development permit and agree to the conditions attached to this permit. Signature: Print Name: This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: ***BUILDING PERMIT CONDITIONS*** 2: Work shall be installed in accordance with the approved construction documents, and any changes made during construction that are not in accordance with the approved construction documents shall be resubmitted for approval. 3: All permits, inspection record card and approved construction documents shall be kept at the site of work and shall be open to inspection by the Building Inspector until final inspection approval is granted. 4: All construction shall be done in conformance with the Washington State Building Code and the Washington State Energy Code. 5: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of this requirement. 6: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center. 7: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. PERMIT INSPECTIONS REWIRED Permit Inspection Line: (206) 438-9350 1700 BUILDING FINAL** CITY OF TUK►. �A Community Development Department Public Works Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.TukwilaWA.gov Building Permit No. t21 �D -02 Project No. Date Application Accepted: Date Application Expires: (For office use only) CONSTRUCTION PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **Please Print** SITE LOCATION Site Address: / (� )LA.\inc c+\j".\\,icr\j".\\,Tenant Name: t e\Q ro�c!'t_ PROPERTY OWNER Name: a , ctin vt:ve \A„ Address: 13430 E \T kms.'\ (WNER\ Name: 1 Phone: 206r _75.5..... 7, • 5 t it¢ t Pi o •i` •1 ioc- Address: 2seeo c CeA tr , A \\ a City: ---c-,:_„,...,\,,_ State: 1 ' k Zip: co 88 CONTACT PERSON - person receiving all project communication Name: a , ctin vt:ve \A„ Address: 13430 E \T kms.'\ City: (. a .wv t'1e, State: \ _ W f iA Zip: 012. *CJ Phone: 206r _75.5..... 7, Email: r ```` as -oA .c(44i. (P? ")liast t►). COQ GENERAL CONTRACTOR INFORMATION Company Name: n oNv‘Mkx6iCtAiktc.05 C\ I' Address: 1 --*30 1\1E_ \\. f A City: \/J066\i\Vii, \ State: sW ��t Zip: t072_ Phone: 206- 16-3----r10- ax: Email: Contr Reg No.: Exp Date: Tukwila Business License No.: H:\Applications\Forms-Applications On Line\2012 Applications\Permit Application Revised - 2-7-12.docx Revised: February 2012 hh au� King Co Assessor's Tax No.: Suite Number: Floor: New Tenant: ❑ Yes No ARCHITECT OF RECORD Company Name: c,,,,,,� 4, N.550G la,45 Architect Name: z..,,,,...(2p Address: \C\ k_ito \ LkO*k n `k :1 City: ��`ni1�0� State: W 1 i Zip: w3/00 Phone: Liza 7,0,63tax. 7,0,63t Email: ENGINEER OF RECORD Company Name: / j _ 1 �p �� tA 50cortcS Lo-'��l Engineer Name: .61vale as x'v.. 1 Address: TkLkOk Lke1 kit-U.):,1t- 30 5, City:7 Ly 64 `moo �. State: ` 1 k Zip: Qe0 �J�1 l Phone: 7Jijrgtec,695gFax: 7 Email: LENDER/BOND ISSUED (required for projects $5,000 or greater per RCW 19.27.095) Name: /T / 47—,--- Address: City: State: Zip: Page 1 of 4 BUILDING PERMIT INFORMATI' - 206-431-3670 co Valuation of Project (contractor's bid price): $ 2C71 COO `` ,1Existing Building Valuation: $ Describe the scope of work (please provide detailed information): n5 L\\ 11 c, 1'c�Aw \,l—c� �•, ; s5; cA, L...i p ,GLA 1 -- �` fp le en 4 cO /Cr�ct x,,, ,'44 (J 4,\MAc-0-t. -�.r.— ke \\ Will there be new rack storage? ❑ ....Yes 0.No If yes, a separate permit and plan submittal will be required. Provide All Building Areas in Square Footage Below PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact: Handicap: Will there be a change in use? ❑ Yes ❑ No If "yes", explain: FIRE PROTECTION/HAZARDOUS MATERIALS: ❑ Sprinklers D Automatic Fire Alarm None ❑ Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? 0 Yes 0 No If "yes attach list of materials and storage locations on a separate 8-1/2" x 11" paper including quantities and Material Safety Data Sheets. SEPTIC SYSTEM 0 On-site Septic System — For on-site septic system, provide 2 copies of a current septic design approved by King County Health Department. H:Wpplications\Forms-Applications On Line12012 Applications\Permit Application Revised - 2-7-12.docx Revised: Febniary 2012 bh Page 2 of 4 Existing Interior Remodel Addition to Existing Structure New Type of Construction per IBC Type of Occupancy per IBC 1St Floor 2nd Floor - 3rd Floor Floors thru Basement Accessory Structure* Attached Garage Detached Garage Attached Carport Detached Carport Covered Deck Uncovered Deck PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact: Handicap: Will there be a change in use? ❑ Yes ❑ No If "yes", explain: FIRE PROTECTION/HAZARDOUS MATERIALS: ❑ Sprinklers D Automatic Fire Alarm None ❑ Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? 0 Yes 0 No If "yes attach list of materials and storage locations on a separate 8-1/2" x 11" paper including quantities and Material Safety Data Sheets. SEPTIC SYSTEM 0 On-site Septic System — For on-site septic system, provide 2 copies of a current septic design approved by King County Health Department. H:Wpplications\Forms-Applications On Line12012 Applications\Permit Application Revised - 2-7-12.docx Revised: Febniary 2012 bh Page 2 of 4 1 PUBLIC WORKS PERMIT INF( IATION — 206-433-0179 Scope of Work (please provide detailed information): Call before you Dig: 811 Please refer to Public Works Bulletin #1 for fees and estimate sheet. Water District ❑ .. Tukwila ❑ ...Water District #125 ❑ .. Water Availability Provided Sewer District ❑ .. Tukwila ❑ .. Sewer Use Certificate ❑... Highline ❑ ...Valley View ❑...Renton ❑ ...Sewer Availability Provided 0... Renton 0... Seattle Septic System: 0 On-site Septic System — For on-site septic system, provide 2 copies of a current septic design approved by King County Health Department. Submitted with Application (mark boxes which apply): ❑ .. Civil Plans (Maximum Paper Size — 22" x 34") 0 .. Technical Information Report (Storm Drainage) ❑ .. Bond 0... Insurance ❑... Easement(s) Proposed Activities (mark boxes that apply): ❑ .. Right-of-way Use - Nonprofit for less than 72 hours 0 .. Right-of-way Use - No Disturbance . Construction/Excavation/Fill - Right-of-way 0 Non Right-of-way ❑ .. Total Cut ❑ .. Total Fill cubic yards cubic yards ❑ .. Sanitary Side Sewer ❑ .. Cap or Remove Utilities 0 .. Frontage Improvements ❑ .. Traffic Control ❑ .. Backflow Prevention - Fire Protection Irrigation Domestic Water ❑. ❑. Geotechnical Report .. Maintenance Agreement(s) ❑ .. Traffic Impact Analysis ❑ .. Hold Harmless — (SAO) ❑ .. Hold Harmless — (ROW) 0...Right-of-way Use - Profit for less than 72 hours ❑ ... Right-of-way Use — Potential Disturbance ❑... Work in Flood Zone ❑... Storm Drainage 0...Abandon Septic Tank ... Curb Curb Cut 0...Pavement Cut 0... Looped Fire Line ❑ .. Permanent Water Meter Size (1) " WO # ❑ .. Temporary Water Meter Size (1) " WO # ❑ .. Water Only Meter Size WO # ❑ .. Sewer Main Extension Public ❑ Private 0 ❑ .. Water Main Extension Public ❑ Private 0 ❑... Grease Interceptor ❑ ... Channelization 0... Trench Excavation 0...Utility Undergrounding (2) " WO # (3) " WO # (2) " WO # (3) " WO # ❑ .. Deduct Water Meter Size 53 FINANCE INFORMATION Fire Line Size at Property Line ❑ .. Water ❑ .. Sewer 0 .. Sewage Treatment Monthlv Service Billing to: Name: Mailing Address: Number of Public Fire Hydrant(s) Day Telephone: Water Meter Refund/Billing: Name: Mailing Address: City State Zip Day Telephone: City State Zip H:\ApplicationskForms-Applications On Line \2012 Applications\Permit Application Revised - 2-7-12.docx Revised: February 2012 bh Page 3 of 4 PERMIT APPLICATION NOTES — Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER 0 UT D AG NT:i/ Signature: G, Date: 03/(p Print Name: /1 3f 11G If Day Telephone: �z� 890 1109 Mailing Address: ?®.A 5-6 9 H:Wpplications\Forms-Applications On Line\2012 Applications\Permit Application Revised - 2-7-12.docx Revised: February 2012 hh City State Zip Page 4 of 4 Cash Register Receipt City of Tukwila DESCRIPTIONS ACCOUNT PermitTRAK QUANTITY PAID $510.92 D16-0248 Address: 344 SOUTHCENTER MALL Apn: 9202470010 $510.92 DEVELOPMENT $486.80 PERMIT FEE R000.322.100.00.00 0.00 $482.30 WASHINGTON STATE SURCHARGE B640.237.114 0.00 $4.50 TECHNOLOGY FEE $24.12 TECHNOLOGY FEE TOTAL FEES PAID BY RECEIPT: R9427 R000.322.900.04.00 0.00 $24.12 $510.92 Date Paid: Thursday, September 15, 2016 Paid By: MATT BRICKWELL Pay Method: CREDIT CARD 615115 Printed: Thursday, September 15, 2016 2:51 PM 1 of 1 CSYSTEMS Cash Register Receipt City of Tukwila DESCRIPTIONS I ACCOUNT 1 QUANTITY PAID PermitTRAK $313.50 D16-0248 Address: 344 SOUTHCENTER MALL Apn: 9202470010 $313.50 DEVELOPMENT $313.50 PLAN CHECK FEE TOTAL FEES PAID BY RECEIPT: R9362 R000.345.830.00.00 0.00 $313.50 $313.50 Date Paid: Thursday, September 08, 2016 Paid By: MATT BRICKNELL Pay Method: CREDIT CARD 418071 Printed: Thursday, September 08, 2016 12:17 PM 1 of 1 CPSYSTEMS 0 ox cc ..k IW w w o 1- � Z �= c 0 WO u 0 a U co U m 03 0 W 0. 0 BOTTOM VIEW CO m 5 cccc O J z Z ={ N �m�LL 2 U U 0 o 2 2 0) = Y R00,1 � 11 lUgg!V 6 CH N W ` V 0 <oy c ` IJIMP 7=7 oat 04 0 r4 ww<LAJ :'n . n. 1 � - a Q CI) N CO 0 CO DESCRIPTION N m m O O W LLI PERWIIT CENTER O 0 0 O 0 W a 0 W_ 0 , 2 Z Z > 0 a • m W LL 0 X X N E W Z O Z _ Cl M; oo_c - a�o Z • o 1 0 m r r c7 ,,, Z `00 0 .-i i o• 0 , 2 Z Z > 0 a • m W LL 0 X X N E W Z O Z _ Cl M; oo_c - a�o Z • o 1 0 m PE MMT R.Ctiy -tED FOR: Ea V chanjcal Lk [cctricai Ilumbing Cik‘ Piping City of Tukwila DIVISION REVISIONS P'o changeshell, be made to the scope f7f 1•'° rk "ithout prior approval of uka Building Division_ require a new plan submittal n`.J may inc'ude additional plan review fees. y.. FILE COPY Permit No. 111,,- O!8 Plan review approval is subject to errors and omissions. Approval of construction documents does not authorize the violation of any adopted code or ordinance. Receipt of approved Field Copy and conditions is acknowledge; By: Date: G/ City of Tukwila BUILDING DIVISION REVIEWED FOR CODE COMPLIANCE APPROVED SEP 14 2016 City of Tukwila BUILDING DIVISION DIS °Ali 8 PROPRIETARY INFORMATION THE INFORMATION CONTAINED IN THIS SET OF CONSTRUCTION DOCUMENTS IS PROPRIETARY BY NATURE. ANY USE OR DISCLOSURE OTHER THAN THAT WHICH RELATES TO THE AT&T MOBILITY SERVICES IS STRICTLY PROHIBITED. VICINITY MAP '4 3 Eon 9.11 SITE -f c... at&t Your world. Delivered SOUTHCENTER MALL 2800 SOUTHCENTER MALL SEATTLE, WA 98188 GENERAL LOCATION MAP 1 f i } 2}f. IA . tr= f t; t 4.1 11r, '1I j r {! 7 -r- a I'• l • tio• , Oat Nalavi m+i ) 4s,:-.4.4 r r 4 , .1 f 1 1� gi, au>.,.r 1I'��. lw.. ` , -J1,b � I j�` i Z• ♦,\ 1rf 1 *aitri • 1k-�'S %4 �V i 111 . {is f 14ar 4�. 711/ 4 NTS !"i1 to l�� 1 Ift -I +'� 1 r 1 1>Qf " "FITS DRIVING DIRECTIONS DEPART 16331 NE 72ND WAY ON NE 72ND WAY (EAST); TURN RIGHT (SOUTH) ONTO 164TH AVE NE, THEN IMMEDIATELY TURN RIGHT (WEST) ONTO BEAR CREEK PKWY; TURN LEFT (WEST) ONTO (NE) LEARY WAY (NE); TAKE RAMP ONTO WA -520 W / SEATTLE; TAKE RAMP (RIGHT) ONTO 1-405 S / RENTON; AT EXIT 1, TURN RIGHT ONTO RAMP WA -181 S / W. VALLEY HWY. / TUKWILA; TURN RIGHT (EAST) ONTO INTERURBAN AVE S *ROAD NAME CHANGES TO WA -181 [W VALLEY HWY]*; TURN RIGHT (WEST) ONTO STRANDER BLVD; TURN RIGHT (NORTH) ONTO ANDOVER PARK W; TURN LEFT (WEST) ONTO SOUTHCENTER MALL; ARRIVE 2800 SOUTHCENTER MALL APPROVAL/SIGN OFF OF CONSTRUCTION DRAWINGS CONSULTANT GROUP SIGN OFF DATE SIGNATURE AT&T SIGN OFF DATE SIGNATURE CONSTRUCTION COORDINATOR COMPLIANCE LANDLORD'S REPRESENTATIVE CONSTRUCTION MANAGER PROJECT MANAGER SOUTHCENTER MALL 2800 SOUTHCENTER MALL DEPLOYMENT MANAGER SITE ACQUISITION EQUIPMENT ENGINEER ZONING INTERCONNECT SITE AQUISITION MANAGER OPERATIONS PERMITS RF ENGINEER RF ENGINEER MANAGER REVIEWERS SHALL CLEARLY PLACE INITIALS ADJACENT TO EACH REDLINE NOTE AS DRAWINGS ARE BEING REVIEWED PROJECT INFORMATION APPLICANT: AT&T SERVICES, INC. 16331 NE 72ND WAY REDMOND, WA 98052 CONTACT: STEVE EVENSON PHONE: 425-647-7768 email: se5646@att.com PROJECT ARCHITECT: CAMP & ASSOCIATES, INC. 19401 40TH AVE W., SUITE 304 LYNNWOOD WA 98036 CONTACT: ERIC CAMP (OFFICE) (425) 740-6390 ELECTRICAL ENGINEER CAMP & ASSOCIATES, INC. 19401 40TH AVE W., SUITE 3 LYNNWOOD, WA 98036 PHONE: 714-465-8959 CONTACT: STEVE WOODRUFF LAND OWNER: WESTFIELD PROPERRTY TAX DEPARTMENT 2800 SOUTHCENTER MALL TUKWILLA, WA 98188 PHONE: CONTACT: UTILITY INFORMATION: POWER CO.: PUGET S TELCO: TU CODE INFORMATION: BUILDING CODE: ZONING MASSIF! IBC, STANDARDS AND AMENDMENTS WAC 51-50 IMC, STANDARDS AND AMENDMENTS WAC 51-52 IFC, STANDARDS AND AMENDMENTS WAC 51-54 UPC, STANDARDS AND AMENDMENTS WAC 5156, 51-57 TUC CONSTRUCTION PE: VB OCCUPANCY: S-2 JURISDICTION: CITY OF TUKWILLA, WA SITE LOCATION: (BASED ON NAD 83) PARCEL NUMBER: 920247-0010 LATITUDE: 47° 27' 25.98" N LONGITUDE: 122° 15' 37.08" W ELEVATION AT GROUND LEVEL AMSL: 30.00' AMSL PROJECT AREA: %AA APPROX. 31 SQ. FT. WITHIN A 433 SQ. FT. EQUIPMENT R GGvNOC U CIT GENERAL INFORMATION: SE? 1. PARKING REQUIREMENTS ARE UNCHANGED. SCGCG 2. TRAFFIC IS UNAFFECTED. �aM1� O�_ •��Q 3. SIGNAGE IS PROPOSED. a � N • � 4. NO ADDITIONAL IMPERVIOUS AREA IS PROPOSED. + oso PROJECT DESCRIPTION: AT&T PROPOSES ADD RF EQUIPMENT CABINETS IN AN EXISTING TELECOMMUNUICATIONS ROOM W/ ADDITIONAL COAX FOR NEW GPS ANTENNA NOTE: ARCHITECTURAL STAMP AND SIGNATURE APPLIES TO SHEETS IN DRAWING INDEX INDICATED BY AN X ON LEFT MOST COLUMN. DRAWING INDEX DWG. NO. DESCRIPTION X T-1.0 TITLE SHEET X G-1.0 GENERAL NOTES X A-1.0 PARTIAL GROUND LEVEL GARAGE PLAN x A-2.0 PARTIAL ROOF LEVEL GARAGE PLAN X A-3.0 EQUIPMENT ROOM PLANS X A-4.0 CONSTRUCTION DETAILS X E-1.0 ONE -LINE DIAGRAM X E-2.0 ELECTRICAL POWER & GROUNDING PLANS X E-3.0 GROUNDING DETAILS REVIEWED FOR CODE COMPLIANC • ARP ROVED SEP 1 4 2016 City of Tukwila BUILDING DIVISION LEGAL DESCRIPTION WEA SOUTHCENTER LLC BSIP PER BSIP REC VOL 256 PGS 1-9 WHICH REPLACES BSIP REC VOL 249 PGS 77-84 (AKA PARCEL A TUKWILA BSIP #L10-032 REC #20101021000765) pII1lp OIJI'b ((C CAMP+ ASSOCIATES 19401 40TH AVE. W.. SUITE 304 LYNNWOOD. WA 98036 PHONE: (425) 740-6390 FAX: (425) 224-1614 WWW.CAMPASSOC.COM DATE: 7/23/14 DRAWN BY: GA CHECKED BY: EJC REVISIONS REV.: DATE: DESCRIPTION: BY: QO 7 /23/17 ISSUED FOR PRELIM PERMR GA SITE SOUTHCENTER MALL 2800 SOUTHCENTER MALL SEATTLE, WA 98188 SHEET TITLE TITLE SHEET SHEET NUMBER T-1.0 GENERAL NOTES: 1. VERIFY AND CONFIRM ALL DIMENSIONS AND CONDITIONS. NOTIFY AT&T AND ARCHITECT OF ANY DISCREPANCIES PRIOR TO START OF WORK. 2. DRAWINGS ARE NOT TO BE SCALED, WRITTEN DIMENSIONS TAKE PRECEDENCE, THIS SET OF DOCUMENTS IS INTENDED TO BE USED FOR DIAGRAMMATIC PURPOSES ONLY, UNLESS NOTED OTHERWISE. THE GENERAL CONTRACTOR'S SCOPE OF WORK SHALL INCLUDE FURNISHING ALL MATERIALS, EQUIPMENT, LABOR, AND ANY REQUIREMENTS DEEMED NECESSARY TO COMPLETE PROJECT AS DESCRIBED IN THE DRAWINGS AND OWNER'S PROJECT MANUAL. 3. PRIOR TO THE SUBMISSION OF BIDS, CONTRACTORS INVOLVED SHALL VISIT THE J08 SITE TO FAMILIARIZE THEMSELVES WITH ALL CONDITIONS AFFECTING THE PROPOSED PROJECT. CONTRACTORS SHALL VISIT THE CONSTRUCTION SITE WITH THE CONSTRUCTION/CONTRACT DOCUMENTS TO VERIFY FIELD CONDITIONS AND CONFIRM THAT THE PROJECT WILL BE ACCOMPLISHED AS SHOWN. PRIOR TO PROCEEDING WITH CONSTRUCTION, ANY ERRORS, OMISSIONS, OR DISCREPANCIES SHALL BE BROUGHT TO THE ATTENTION OF THE ARCHITECT/ENGINEER VERBALLY AND IN WRITING. 4. AT&T, AND THE ARCHITECTS/ENGINEERS HAVE MADE EVERY EFFORT TO SET FORTH IN THE CONSTRUCTION AND CONTRACT DOCUMENTS THE COMPLETE SCOPE OF WORK. CONTRACTORS BIDDING THE JOB ARE NEVERTHELESS CAUTIONED THAT MINOR OMISSIONS OR ERRORS IN THE DRAWINGS AND OR SPECIFICATIONS SHALL NOT EXCUSE SAID CONTRACTOR FROM COMPLETING THE PROJECT AND IMPROVEMENTS IN ACCORDANCE WITH THE INTENT OF THESE DOCUMENTS. THE BIDDER SHALL BEAR THE RESPONSIBILITY OF NOTIFYING (IN WRITING) AT&T, AND THE ARCHITECT/ENGINEER OF ANY CONFLICTS, ERRORS, OR OMISSIONS PRIOR TO SUBMISSION OF CONTRACTOR'S PROPOSAL. IN THE EVENT OF DISCREPANCIES THE CONTRACTOR SHALL PRICE THE MORE COSTLY OR EXTENSIVE WORK, UNLESS DIRECTED OTHERWISE. 5. THE CONTRACTOR SHALL SUPERVISE AND DIRECT THE PROJECT DESCRIBED IN THE CONTRACT DOCUMENTS. THE CONTRACTOR SHALL BE SOLELY RESPONSIBLE FOR ALL CONSTRUCTION MEANS, METHODS, TECHNIQUES, SEQUENCES, AND PROCEDURES FOR COORDINATING ALL PORTIONS OF THE WORK UNDER THE CONTRACT. 8. THE CONTRACTOR SHALL INSTALL ALL EQUIPMENT AND MATERIALS ACCORDING TO MANUFACTURER'S/VENDOR'S SPECIFICATIONS UNLESS NOTED OTHERWISE OR WHERE LOCAL CODES OR ORDINANCES TAKE PRECEDENCE. 7. ALL WORK PERFORMED ON THE PROJECT AND MATERIALS INSTALLED SHALL BE IN STRICT ACCORDANCE WITH ALL APPLICABLE CODES, REGULATIONS, AND ORDINANCES. CONTRACTOR SHALL GIVE ALL NOTICES AND COMPLY WITH ALL LAWS, ORDINANCES, RULES, REGULATIONS AND LAWFUL ORDERS OF ANY PUBLIC AUTHORITY, MUNICIPAL AND UTILITY COMPANY SPECIFICATIONS, AND LOCAL AND STATE JURISDICTIONAL CODES BEARING ON THE PERFORMANCE OF THE WORK. 8. CONTRACTOR SHALL PROVIDE, AT THE PROJECT SITE, A FULL SET OF CONSTRUCTION DOCUMENTS UPDATED WITH THE LATEST REVISIONS AND ADDENDA OR CLARIFICATIONS FOR USE BY ALL PERSONNEL INVOLVED WITH THE PROJECT. 9. THE STRUCTURAL COMPONENTS OF ADJACENT CONSTRUCTION OR FACILITIES ARE NOT TO BE ALTERED BY THIS CONSTRUCTION PROJECT UNLESS NOTED OTHERWISE. ENSURE THAT EXCAVATION DOES NOT AFFECT ADJACENT STRUCTURES. 10. SEAL ALL PENETRATIONS THROUGH FIRE -RATED AREAS WITH U.L. LISTED OR FIRE MARSHALL APPROVED MATERIALS IF APPLICABLE TO THIS FACILITY AND OR PROJECT SITE. 11. CONTRACTOR TO PROVIDE A PORTABLE FIRE EXTINGUISHER WITH A RATING OF NOT LESS THAN 2-A OR 2 -Al OBC WITHIN 75 FEET TRAVEL DISTANCE TO ALL PORTIONS OF PROJECT AREA DURING CONSTRUCTION. 12. CONTRACTOR SHALL MAKE NECESSARY PROVISIONS TO PROTECT EXISTING IMPROVEMENTS, EASEMENTS, PAVING, CURBING, ETC. DURING CONSTRUCTION. UPON COMPLETION OF WORK, CONTRACTOR SHALL REPAIR ANY DAMAGE THAT MAY HAVE OCCURRED DUE TO CONSTRUCTION ON OR ABOUT THE PROPERTY. 13. CONTRACTOR SHALL KEEP GENERAL WORK AREA CLEAN AND HAZARD FREE DURING CONSTRUCTION AND DISPOSE OF ALL DIRT, DEBRIS, AND RUBBISH. CONTRACTOR SHALL REMOVE EQUIPMENT NOT SPECIFIED AS REMAINING ON THE PROPERTY OR PREMISES. SITE SHALL BE LEFT IN CLEAN CONDITION AND FREE FROM PAINT SPOTS, DUST, OR SMUDGES OF ANY NATURE. 14, THE CONTRACTOR SHALL RECEIVE WRITTEN AUTHORIZATION TO PROCEED WITH CONSTRUCTION PRIOR TO STARTING WORK ON ANY ITEM NOT CLEARLY DEFINED BY THE CONSTRUCTION DRAWINGS/CONTRACT DOCUMENTS. 15. THE CONTRACTOR SHALL PERFORM WORK DURING OWNER'S PREFERRED HOURS TO AVOID DISTURBING NORMAL BUSINESS. 16. THE CONTRACTOR SHALL PROVIDE AT&T. PROPER INSURANCE CERTIFICATES NAMING AT&T. AS ADDITIONAL INSURED, AND AT&T. PROOF OF LICENSE(S) AND PE & PD INSURANCE. 17. CONTRACTOR SHALL BE RESPONSIBLE FOR SCHEDULING AND COORDINATING ALL INSPECTIONS. 18. CAUTION! CALL BEFORE YOU DIG! BURIED UTILITIES EXIST IN THE AREA AND UTILITY INFORMATION SHOWN MAY NOT BE COMPLETE. CONTACT THE ONE -CALL UTILITY LOCATE SERVICE A MINIMUM OF 48 HOURS PRIOR TO CONSTRUCTION. IN WASHINGTON CALL: 1-800-424-5555. 19. CONTRACTOR TO DOCUMENT ALL WORK PERFORMED WITH PHOTOGRAPHS AND SUBMIT TO AT&T. ALONG WITH REDLINED CONSTRUCTION SET. 20. CONTRACTOR TO DOCUMENT ALL CHANGES MADE IN THE FIELD BY MARKING UP (REDLINING) THE APPROVED CONSTRUCTION SET AND SUBMITTING THE REDLINED SET TO AT&T. UPON COMPLETION. 21. FOR COLLOCATION SITES: CONTACT TOWER OWNER REPRESENTATIVE FOR PARTICIPATION IN BID WALK. 22. CONTRACTOR IS TO COORDINATE ALL POWER INSTALLATION WITH POWER COMPANY AS REQUIRED. CONTRACTOR TO REPORT POWER INSTALLATION COORDINATION SOLUTION(S) TO NETWORK CARRIER REPRESENTATIVE, PROJECT CONSTRUCTION MANAGER AND ARCHITECT. 23. ANY SUBSTITUTIONS OF MATERIALS AND/OR EQUIPMENT, MUST BE APPROVED BY AT&T CONSTRUCTION MANAGER. 24. WHERE ANCHORING TO A CONCRETE ROOF SLAB, CONTRACTOR SHALL CONFIRM (PRIOR TO SUBMITTING BID) WITH CONSULTING CONSTRUCTION COORDINATOR AND ARCHITECT THE PRESENCE OF POST TENSION TENDONS. CONTRACTOR SHALL INCLUDE PROVISIONS FOR X-RAY PROCEDURES TO LOCATE THE TENDONS. GENERAL NOTES (CONT'D): 25. CONTRACTOR SHALL USE STAINLESS STEEL METAL LOCKING TIES FOR ALL CABLE TRAY TIE DOWNS AND ALL OTHER GENERAL TIE DOWNS (WHERE APPLICABLE). PLASTIC ZIP TIES SHALL NOT BE PERMITTED FOR USE ON AT&T PROJECTS. RECOMMENDED MANUFACTURER SHALL BE: PANDUIT CORP. METAL LOCKING TIES MODEL NO. MLT4S-CP UNDER SERIES -304 (OR EQUAL). PANDUIT PRODUCT DISTRIBUTED BY TRIARC OF TACOMA, WA. 26. MAINTAIN THE INTEGRITY OF THE BUILDING ENVELOP AND CONSTRUCT BARRIERS IN THE AREA OF WORK TO PREVENT DAMAGE FROM WEATHER AND CONSTRUCTION DUST AND DEBRIS. SAFETY PROCEDURES FALL PROTECTION METHODS TO BE PER FEDERAL, STATE, LOCAL, OSHA, AT&T REQUIREMENTS. SYMBOLS AND ABBREVIATIONS A/C AGL APPROX BLDG BLK CLG CLR CONC CONST CONT DBL DIA DIAG DN DEF DWG EA ELEV ELEC E0 EQUIP EXT FIN FLUOR FLR FT GA GALV GC GRND GYP BD AIR CONDITIONING ABOVE FINISH GRADE APPROXIMATELY BUILDING BLOCKING CEILING CLEAR CONCRETE CONSTRUCTION CONTINUOUS DOUBLE DIAMETER DIAGONAL DOWN DETAIL DRAWING EACH ELEVATION ELECTRICAL EQUAL EQUIPMENT EXTERIOR FINISH FLOURESCENT FLOOR FOOT GAUGE GALVANIZED GENERAL CONTRACTOR GROUND GYPSUM WALL BOARD T TELEPHONE P POWER G GROUND WIRE -COAX- COAXIAL CABLE ® ANTENNA [E] [N] CENTERLINE EXISTING NEW DETAIL NUMBER SHEET NUMBER HORZ HR HT HVAC ID IN INFO INSUL INT IBC LBS MAX MECH MTL MFR MGR MIN MISC NA NIC NTS HORIZONTAL HOUR HEIGHT HEATING VENTILATION AIR CONDITIONING NSIDE DIAMETER NCH NFORMATION NSULATION NTERIOR NTERNATIONAL BUILDING CODE POUNDS MAXIMUM MECHANICAL METAL MANUFACTURE MANAGER MINIMUM MISCELLANEOUS NOT APPLICABLE NOT IN CONTRACT NOT TO SCALE OC ON CENTER OD OUTSIDE DIAMETER PLYWD PROJ PROP PT REO RM RO SHT SIM SPEC 5F SS STL STRUCT STD SUSP AND OWNER PLYWOOD PROJECT PROPERTY PRESSURE TREATED REQUIRED ROOM ROUGH OPENING SHEET SIMILAR SPECIFICATION SQUARE FOOT STAINLESS STEEL STEEL STRUCTURAL STUD SUSPENDED THRU THROUGH TNNG TINNED TYP TYPICAL UNO UNLESS NOTED OTHERWISE VERT VERTICAL VIF VERIFY IN FIELD W/ W/O WP NOTE: STRUCTURAL DRAWINGS AND NOTES SHALL TAKE PRECEDENCE OVER ALL DRAWINGS AND NOTES. WITH WITHOUT WATER PROOF REc ��uKwILA CITY OF SEP °82°1 PERMIT GOITER REVIEWED FOR CODE COMPLIANCE ' APPROVED SEP 14 2016 City of Tukwila BUILDING DIVISION CAMP+ ASSOCIATES 19401 40TH AVE. W., SUITE 304 LYNNWOOD, WA 98036 PHONE: (425) 740-6390 FAX: (425) 224-1814 W W W.CAMPASSOC.COM DATE: 7/23/14 DRAWN BY: GA CHECKED BY: EJC REVISIONS REV.: DATE: DESCRIPTION: BY: Q UED PERMIT GA SITE SOUTHCENTER MALL 2800 SOUTHCENTER MALL SEATTLE, WA 98188 SHEET TITLE GENERAL NOTES SHEET NUMBER G-1 EXISTING PARKING EXISTING DAS EQUIPMENT ROOM r 03 Ito L „ 71IAI"��7IILD] 5ILC01[ L EXISTING ASPHALT PAVED ACCESS DRIVE EXISTING COAX WAVE GUIDE ENTRY PORT LOCATION EXISTING FIBER DEMARC-VERIFY LOCATION IN FIELD NEW COAX FOR GPS ANTENNA ALONG EXISTING COAX ROUTE IN NEW 2"0 CONDUIT EXISTING TELCO ROOM F -F -F -F -FBF NEW 4"0 CONDUIT FOR FIBER ROUTING TO EXISTING TELCO ROOM NEW VERTICAL 2"0 CONDUIT FOR GPS COAX UP TO ROOF LEVEL GPS ANTENNA REVIEWED FOR CODE COMPLIANCE APPROVED SEP 14 2016 City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA SEP 0 8 2016 PERMIT CENTER 10 20 30 PARTIAL GROUND LEVEL GARAGE PLAN 22'X34" SCALE:1" .10'-0" 11" X 17" SCALE: 1"= 20'-0" OC CAMP+ ASSOCIATES 19401 40TH AVE. W., SURE 304 LYNNWOOD, WA 98036 PHONE: (425) 740-6390 FAX (425) 224-1814 W W W.CAMPASSOC.COM DATE: 7/23/14 DRAWN BY: GA CHECKED BY: EJC REVISIONS REV.: DATE: DESCRIPTION: BY: p 7/23/17 SULM PO MT GA SITE SOUTHCENTER MALL 2800 SOUTHCENTER MALL SEATTLE, WA 98188 SHEET TITLE PARTIAL GROUND LEVEL GARAGE PLAN SHEET NUMBER A-1.0 EXISTING EXISTING DAS EQUIPMENT ROOM BELOW EXISTING PARKING BRIDGE TO ADJACENT UPPER LEVEL PARKING AREA EXISTING PARKING PARKING NEW 2'0 VERTICAL CONDUIT DOWN TO DAS EQUIPMENT ROOM NEW COAX FOR GPS ANTENNA ALONG EXISTING COAX ROUTE IN NEW 2'0 CONDUIT 5 0 0 O 0 0 EXISTING 'rARKING NEW AT&T GPS ANTENNA MOUNTED TO EXISTING COLUMN REVIEWED FOR CODECOMPUANCE APPROVED SEP 14 2016 City of Tukwila BUIL-DING-DIVISION- — ROF TIVKWILA CITY SE? 0 8 2016 PERMIT CENTER 10 20 30 CD PARTIAL ROOF LEVEL GARAGE PLAN 22"X34" SCALE:1" = 10'0" 11" X 1T' SCALE:1" a 20%0" OC CAMP+ ASSOCIATES 19401 40TH AVE. W., SUITE 304 LYNNWOOD, WA 98036 PHONE (425) 740-6390 FAX: (425) 224-1614 VVVVW.CAMPASSOC.COM DATE: 7/23/14 DRAWN BY: GA CHECKED BY: EJC REVISIONS REV.: DATE: DESCRIPTION: BY: Q 7/23/17 ISSUED FOR PRELIM PERMIT GA SITE SOUTHCENTER MALL 2800 SOUTHCENTER MALL SEATTLE, WA 98188 SHEET TITLE PARTIAL ROOF LEVEL GARAGE PLAN SHEET NUMBER A-2.0 OC CAMP+ ASSOCIATES 19401 40TH AVE. W., SUITE 304 LYNNWOOD, WA 98036 PHONE: (425) 740-6390 FAX (425) 224-1614 W W W.CAMPASSOC.COM DATE: 7/23/14 DRAWN BY: GA CHECKED BY: EJC REVISIONS REV., DATE: DESCRIPTION: BY: A 7 /23/17 ISSUED FOR RM PRELIM IT GA 22•-7•• }, 22_7' / 10'-3" LEASE AREA / 2800 SOUTHCENTER MALL SEATTLE, WA 98188 / (E) GROUND BAR (E) GROUND BAR \ \ _fl r -1r I L JIII L J r - -I 1 lir -'ir-"ir—tr--tr--Ir--R--Ir--R--r—rt—rz--rz-- II (E)(0) II 11 JL_JL_-LL0DVZW IIII a -L _ _1 VZW II I --n--n--n—n-�--i.. IIIIII _JI__L-_L__JI__ll__Jl IVZW II 4 In (E) CEILING MOUNTED CABLE LADDER CEILING r ;IIL_JL_JLJ '-j1 �'r I u u (0) VZW II 11 n II u (E) VZW I II 1 u n II r fOj CABLEW TOMOUNTED PROVIDED BY ATC 1 I CAB. MODCELL 4.0 CABINET E VZW EB ERRE CAB. (E) VZW TELCO / CABINET/ L J_LTE r rL- LTE CAB. 4.0 CABINET E VZW EBRELLCAB. TELCO CABINET/ _ L= Lam' L. _i / EXISTING COAX WAVE (0) CEILING MOUNTED CABLE LADDER L_ y L J / ( / \\\\\ in ¶¶--I-F1�f-74r ;; it ,�-/r i - - m r PORT ENTRYLOCATION L j L'/// E A/C DUCTING \ IL- U F �, c"] LL �F� 'G (E) A/C DUCTING i m .al -LIE r 11 \ _ J E A C EXHAUST r- J \ J E A C EXHAUST ( ) / K a o1 ¢ lo v (N) AT&T (N) AT&T (N) AT&T JI H1 ( ) / LOUVER T LJ I-- -r 1 1� (E) A/C UNIT LOUVER (E) TELCO/FIBER L, 1 ugh i.1 p LTE CAB. BATTERY CABINET UMTSIICABI r1=-11 1�I (0) A/C N La AT&T UNIT (E) TELCO/FIBER 1 ;; RRU tor 'J' BOX (E) -MOBILE EQUIPMENT �J 4 DEMARC / / Hi'tt ;,I (E) T -MOB / / / / F , 1 \ \ IT NEW COAX FOR GPS ANTENNA CABINETS rL- L J \ \ \ J '� EQUIPMENT CABINETS `\ i� i� L ' 1—' 11 J \ J ALONG EXISTING COAX ROUTE IN 1- -� NEW 2"0 CONDUIT al l- L_ I_ .I_ JI-_ 11- Irlr;:111---11-1i— I 1— II-- 1 L _ _, 1_ 1- n- n n n --n 11 _IF 11 fr_ r ri II II II II i 1 n II 1 g^ _ (F) DISCONNECT SWITCH I t 1 L _JI JL_ L rir II = Jm-....Ir--II 1 L AFI__ 6 1 11 L- II ( ll"'-il 'fi -it--il 11"'"'ll II II 11 1 L_JL JL_JL_ LL LL__LL__LL_ LL _LL__ll L__L__L _L__L__.11_ JI__ (F) DISCONNECT SWITCH I (0) GROUND BAR 1 _ GROUND BAR \ \ \ \ \ \ L i (E) 1 \ L i i c \\�J \ r�1Y-J �� I \ \\--J r;Y-J �— `-J F F� L J t L --1 LJ r'—Ji \ \ (E) TRANSFORMER TRANSFORMER (0) PANELBOARD (0) PANELBOARD (E) N �/� �'' REjVIEWED FOR CODE - /.. GENE' NEW VERTICAL 2"0 CONDUIT O F uKWILA COMPLIANCE 1PPROVED ■ _' FOR GPS COAX UP TO ROOF V LEVEL GPS ANTENNA NEW 2"0 CONDUIT FOR FIBER SEP o a 2016 L FUS 2016 Ci of Tukwila ROUTING TO EXISTING TELCO ROOM PERMIT CENTER N \ IA to BUIL[�ING DIVISION � 0 4 8 12 0 4 8 12 EXISTING EQUIPMENT ROOM PLAN � XT'SCALSCALE: 3re"c 1'-0'• I � PROPOSED EQUIPMENT ROOM PLAN 22'X94SCALE:SCALE: 9/8"_1'-0" 12 1" X 1T' SCALE: 3/16" = 1'-0" 1"x 1T' SCALE: 3/16"=1,0" OC CAMP+ ASSOCIATES 19401 40TH AVE. W., SUITE 304 LYNNWOOD, WA 98036 PHONE: (425) 740-6390 FAX (425) 224-1614 W W W.CAMPASSOC.COM DATE: 7/23/14 DRAWN BY: GA CHECKED BY: EJC REVISIONS REV., DATE: DESCRIPTION: BY: A 7 /23/17 ISSUED FOR RM PRELIM IT GA SITE SOUTHCENTER MALL 2800 SOUTHCENTER MALL SEATTLE, WA 98188 SHEET TITLE EQUIPMENT ROOM PLANS SHEET NUMBER A-3.0 EXISTING CONCRETE SLAB 1/2"0 KWIK BOLT TZ WITH 2" MIN. EMBEDMENT. INSTALL PER MANUFACTURER SPECS (TYP OF 4, ONE EACH CORNER) -EQUIPMENT CABINET PER PLAN - CABINET ANCHORAGE DET. 22'44" SCALE NTS 11"x1T'SCALE NTS 2 REVIEWED FOR CODE COMPLIANCE APPROVED SEP 14 2016 City of Tukwila BUILDING DIVISION NOTES 1. ALL CUT ENDS OF CABLE LADDER TO BE FILED SMOOTH AND PAINTED WITH MATCHING COLOR. 2. BOTTOM OF CABLE LADDER TO 8E 7'-6" ABOVE FINISH FLOOR. UNLESS NOTED OTHERWISE. 3. INTERFERE THEN CORNER BRACKETS MAY BE ON THE OUTSIDE. 4. CABLE LADDER RUNGS TO BE ON TOP OF HORIZONTAL LADDER AND AWAY FROM WALL ON VERTICAL LADDERS. ALIGNMENT AT SPLICE SLEEVE 1/4" BOLTS WITH STAR WASHERS 5. NUTS TO BE ON BOTTOM OF ASSEMBLY, OR TOWARDS CABLE ABLE LADDER 6. 5/8" THREADED RODS, SUPPORTING CABLE LADDER, SPACED 6'-0" FEET APART. 7. 7. AFTER FINAL LEVELING OF CABLE LADDER CUT ROD SO THAT 1/2" OF THE THREADS ARE EXPOSED BELOW THE NUT. CAP WITH SAUNDERS BROS. PN SB 300-D. 8. ANCHOR ALL ENDS OF CABLE LADDER TO WALL NOTE: CONFIRM LOCATION OF TENDONS IN P.T. SLAB. DO NOT CUT PT SLAB REINFORCING 1. INSTALL UNISTRUT AS REQUIRED OTHERWISE ATTACH DIRECTLY TO CEILING. 2. SEE CABLE LADDER NOTES FOR ADDITIONAL INFORMATION. %/ ///////X SECTION 'B B' AT 'C' CLAMP UNISTRUT P1000T 6 AWG STRANDED GREEN INSULATED COPPER WIRE (TYP. EACH SIDE OF CABLE TRAY) O3 SPLICE DETAIL 1/4" BOLTS WITH STAR WASHERS (TYP.) T & B LUG (TYP.) 6 AWG STRANDED itGREEN INSULATED COPPER WIRE (TYP. ,r EACH SIDE OF CABLE TRAY) L ANCHORAGE: AT CONCRETE USE 3/8" THREADED ROD W/HILTI HY-150 ® MIN. 1 3/4" EMBED. (ICBO# 5193) AT WOOD USE 3/8"X3" LAG BOLTS AT METAL STUDS USE #12X3" SHEET METAL SCREWS (2 MIN. PER UNISTRUT) CABLE LADDER WIDTH 12" MINIMU 1/4" NUT WITH LOCKWASHER (TYP.) CABLE LADDER SPRING NUT 5/8"0 THREADED RODS, TYP. "C" CLAMP (SAUNDERS BROTHE SB -157 SLOTTED HANGER CLIP (3/16" HOT ROLLED HOLE) EQUAL SPACING CABLE LADDER SEE PLAN FOR LOCATIONS O CABLE LADDER DETAIL --- GROUND STRAP BOTH SIDES (TYP.) GROUND BOUNDSTRAP (ONE SIDE ONLY) ALIGNMENT SLEEVE C" CLAMP 0 i�--I•IIId11•I - .r( OF OF CI SEP 0 8 2016 PERMIT CENTER CONNECTION TO CABLE LADDER • CONNECTION TO WALL 2"x6"x24" BATTEN BOARD "C" CLAMP SUPPORT AND BRACKET PLAN AT "T" JUNCTION NOTE: SEE CABLE LADDER NOTES FOR ADDITIONAL INFORMATION. PLAN AT TYPICAL RUN PLAN AT WALL/ CONNECTION O CABLE LADDER DETAIL 3/8"0 EXPANSION BOLT INDOOR CABLE TRAY DETAIL 22"x34" SCALE NTS 11"x1T' SCALE NTS 1 CAMP+ ASSOCIATES 19401 40TH AVE. W., SUITE 304 LYNNWOOD, WA 98036 PHONE: (425) 740-6390 FAX: (425) 224-1614 W W W.CAMPASSOC.COM DATE: 7/23/14 DRAWN BY: GA CHECKED BY: EJC REVISIONS REV.: DATE: DESCRIPTION: BY: Q 7/23/17 SSUED F PRELIM PERMIT OA SITE SOUTHCENTER MALL 2800 SOUTHCENTER MALL SEATTLE, WA 98188 SHEET TITLE CONSTRUCTION DETAILS SHEET NUMBER A-4.0 FEEDER SCHEDULE CD EXISTING O2 (4 #6 & 1 #8 GND) 1" C - NEW ALL CONDUCTORS SHALL BE COPPER STRANDED 600V. RATED WITH THHN INSULATION TO EXISTING BUILDING ELECTRICAL DISTRIBUTION SYSTEM EXISTING 75KVA NEMA 1 DRY TYPE TRANSFORMER 480V PRIMARY 120/240V 10 3W SECONDARY PROVIDE NEW 60A/3P BREAKER TO MATCH EXISTING AMERICAN TOWER PANELBOARD COI OF 1000 �6 St? 01. peRM COOSIA 1. INSTALLATION OF SECONDARY POWER AND CONNECTION TO METER SHALL BE COMPLETED IN COMPLIANCE WITH NATIONAL ELECTRIC CODE, NFPA 70, AND THE STATE OF WASHINGTON LAWS, RULES AND REGULATIONS FOR INSTALLING ELECTRIC WIRES & EQUIPMENT, ALL LATEST ISSUE, AND WITH SPECIFICATIONS PER A.S.T.M. B 231, B 400, I.C.E.A. 5651-401, I.C.E.A. P81-570, & LOCAL PUD. 2. PROVIDE A METER BASE PER LOCAL UTILITY STANDARDS. MOUNT ON SIDE OF OWNER FURNISHED BACK BOARD. 3. UNDERGROUND CONDUIT SHALL BE RIGID POLYVINYL CHLORIDE CONDUIT: SCHEDULE 40, TYPE 1, CONFORMING TO UL ARTICLE 651: WESTERN PLASTICS OR CARLON MANUFACTURER. COUPLINGS SHALL BE SLIP-ON, SOLVENT SEALED T PIPE: SOLVENT, WESTERN TYPE COMPATIBLE WITH PVC DUCT. ALL BENDS SHALL BE "WIDE SWEEP" TYPE WITH A 24" MINIMUM RADIUS. ALL CONDUIT UNDER ROADS SHALL BE RGS, (OR PVC ENCASED IN 8"z18" RED CONCRETE DUCTBANK). 4. CONDUIT USED INDOORS SHALL BE E.M.T., AND RIGID GALVANIZED STEEL FOR OUTDOORS. COUPLINGS SHALL BE RIGID STEEL AND COMPRESSION TYPE FOR E.M.T. SET SCREW FITTINGS ARE NOT PERMITTED. FOR ALL STUBS -UPS, USE RIGID GALVANIZED STEEL CONDUIT. 5. WIRE AND CABLE SHALL BE OF THE TYPE AND SIZE AS REQUIRED BY NEC. THERE WILL BE NO SPLICES ALLOWED. PROVIDE HDPE PULLING HAND HOLES AS NEEDED. 6. CONTRACTOR SHALL PROVIDE TEST OF THE GROUNDING SYSTEM BY CERTIFIED TESTING AGENT. PROVIDE INDEPENDENT TEST RESULTS TO THE PROJECT MANAGER FOR REVIEW. GROUNDING SYSTEM RESISTANCE TO GROUND SHALL NOT EXCEED 5 OHMS. ALL ABOVE GRADE INTERIOR GROUNDING CONNECTORS SHALL BE DOUBLE -LUG COMPRESSION TYPE. ALL BELOW GRADE AND EXPOSED EXTERIOR GROUNDING CONNECTIONS TO PERMANENT EQUIPMENT AND FIXED BUILDING ELEMENTS SHALL BE CADWELD TYPE. CARE SHALL BE TAKEN TO REVIEW CONNECTION LOCATIONS AND MATERIAL TYPES TO AVOID POSSIBLE GALVANIC CORROSION. ALL EXPOSED GROUNDING CONNECTIONS TO BE COATED WITH ANTI -CORROSIVE AGENT SUCH AS "NO -OXY", "NOAOLX" OR "PENETROX". VERIFY PRODUCT WITH PROJECT MANAGER. ALL BOLTS, WASHERS AND NUTS USED ON GROUNDING CONNECTIONS SHALL BE STAINLESS STEEL. 7. ALL EXTERIOR GROUND BARS SHALL BE COATED WITH ANTI -CORROSIVE AGENT SUCH A5 LPS-3 OR AS PER NOTE 6 ABOVE. 8. ALL JUNCTION AND OUTLET BOXES TO BE LABELED WITH KROY TAPE, OR EQUAL, DESIGNATING ALL CIRCUIT NUMBERS CONTAINED IN EACH 80X. 9. CONTRACTOR TO ENSURE ILC PROVIDED WITH (2) INTERNAL LASS. 10. CONTRACTOR SHALL COORDINATE WITH SITE SURVEY TO LOCATE EXISTING UNDERGROUND UTILITIES. WHEREVER POTENTIAL CONFLICTS/ INTERFERENCES EXIST, HAND EXCAVATE TO AVOID DAMAGE. CONTACT ALL UTILITIES TO LOCATE UNDERGROUND PIPING IN PUBLIC ROW. 11. VERIFY THAT A.I.C. OF THE UTILITY DOES NOT EXCEED THE A.I.C. RATING OF THE PROVIDED EQUIPMENT SHELTER PACKAGE. IF OVER 10KAIC, PROVIDE FUSIBLE SERVICE ENTRANCE SWITCH AND CONFIRM LOWERING OF AIC TO ACCEPTABLE LEVELS. 12. UTILITY POINTS OF SERVICE AND WORK / MATERIALS SHOWN ARE BASED UPON PRELIMINARY INFORMATION PROVIDED BY THE UTILITY COMPANIES AND ARE FOR BID PURPOSES ONLY. 13. CONTRACTOR SHALL COORDINATE WITH UTILITY COMPANY FOR FINAL AND EXACT WORK / MATERIALS REQUIREMENTS AND CONSTRUCT TO UTILITY COMPANY ENGINEERING PIANS AND SPECIFICATIONS ONLY. CONTRACTOR SHALL FURNISH AND INSTALL ALL CONDUIT, PULL ROPES, CABLES, PULL BOXES, CONCRETE ENCASEMENT OF CONDUIT (IF REQUIRED), TRANSFORMER PAD, BARRIERS, POLE RISERS, TRENCHING, BACKFILL, PAY ALL UTILITY COMPANY FEES AND INCLUDE ALL REQUIREMENTS IN SCOPE OF WORK. GENRAL NOTES 22"X34" SCALE: NTS 11" X 1T' SCALE: NTS 3 ABBREVIATIONS AWG BCW DWG EMT GEN IGR AMERICAN WIRE GAUGE BARE COPPER WIRE DRAWING ELECTRICAL METALLIC TUBING GENERATOR INTERIOR GROUND RING (HALO) 1.n.11n) (Y�1 UNDERGROUND RACEWAY IMC MGB PCS RGS RWY TYP INTERMEDIATE METALLIC CONDUIT MASTER GROUND BAR PERSONAL COMMUNICATION SYSTEM RIGID GALVANIZED STEEL RACEWAY TYPICAL - - GROUND CONDUCTOR FUSED DISCONNECT PANELBOARD TRANSFORMER FUSED DISCONNECT O FEEDER KEY D LOCAL DISCONNECT GROUND PANELBOARD METER -1, ELECTRICAL I EQUIPMENT L____J ENCLOSURE ELECTRICAL SERV! WEATHERHEAD OGROUND ROD ■ EXOTHERMIC WELD • COMPRESSION TYPE CONNECTION TELEPHONE SERVICE WEATHERHEAD ONE -LINE DIAGRAM 22" X34" SCALE: NTS 11" X 1T' SCALE: NTS 1 LEGEND/ABBREVIATIONS 22"X34" SCALE: NTS 11 X1T SCALE NTS OC CAMP+ ASSOCIATES 19401 40TH AVE. W., SUITE 304 LYNNWOOD, WA 98036 PHONE: (425) 740-6390 FAX: (425) 224-1814 W W W.CAMPASSOC.COM DATE: 7/23/14 DRAWN BY: GA CHECKED BY: EJC REVISIONS ATT pQ 7/23/17 60 A. BUS 208 Y/ 120 VOLT, 3 PHASE, 4 WIRE 10000 AMPERE PANEL SHORT CIRCUIT RATING PANEL TYPE: NQOD PANEL MOUNTING: SURFACE 2800 SOUTHCENTER MALL SEATTLE, WA 98188 NOTE: DESCRIPTION TOTAL BREAKER CCT PH CCT BREAKER TOTAL DESCRIPTION (VA) A / P A / P (VA) RECTIFIER 1600 30 / 1 A 2 30 / 1600 RECTIFIER 1600 / 2 3 B 4 / 2 1600 RECTIFIER 1600 30 / 5 C 6 30 / 1600 RECTIFIER 1600 / 2 7 A 8 / 2 1600 RECTIFIER 1600 30 / 9 8 10 30 / 1600 RECTIFIER 1600 / 2 11 C 12 / 2 1600 SPACE / 13 A 14 / SPACE SPACE / 15 B 16 / SPACE SPACE / 17 C 18 60 / SURGE ARRESTOR SPACE / 19 A 8 2021 22 / SPACE / 23 C 24 / 3 -WAGE PANEL LOADING SUMMARY LOAD TYPE CONNECTED POWER LOAD NEC CALCULATED LOAD FACTOR KVA FACTOR LOAD LIGHTING INCANDESCENT 0.0 KW ® 100% = 0.0 ® 100% = 0.0 KVA FLUORESCENT 0.0 KW @ 95% = 0.0 • 100% = 0.0 KVA RECEPTACLES FIRST 10 KW 0.2 KW CO 100% = 0.2 4D 10% = 0.2 KVA REMAINDER 0.0 KW @ 100% = 0.0 to 50% = 0.0 KVA MOTORS LARGEST 0.0 KW ® 80% = 0.0 0 125% = 0.0 KVA REMAINDER 0.0 KW ® 80% = 0.0 ® 100% = 0.0 KVA OTHER 12.8 KW • 100% = 12.8 ® 100% = 12.8 KVA TOTAL 12.8 KW 12.8 KVA 12.8 KVA PHASE "A" 7.8 KW PANEL A-8 1000 54 AMPERES PHASE "8" 6.4 KW POWER B -C 100100% PHASE PHASE "C" 6.4 KW FACTOR 96% 100% C -A 100% BALANCE TO EXISTING BUILDING ELECTRICAL DISTRIBUTION SYSTEM EXISTING 75KVA NEMA 1 DRY TYPE TRANSFORMER 480V PRIMARY 120/240V 10 3W SECONDARY PROVIDE NEW 60A/3P BREAKER TO MATCH EXISTING AMERICAN TOWER PANELBOARD COI OF 1000 �6 St? 01. peRM COOSIA 1. INSTALLATION OF SECONDARY POWER AND CONNECTION TO METER SHALL BE COMPLETED IN COMPLIANCE WITH NATIONAL ELECTRIC CODE, NFPA 70, AND THE STATE OF WASHINGTON LAWS, RULES AND REGULATIONS FOR INSTALLING ELECTRIC WIRES & EQUIPMENT, ALL LATEST ISSUE, AND WITH SPECIFICATIONS PER A.S.T.M. B 231, B 400, I.C.E.A. 5651-401, I.C.E.A. P81-570, & LOCAL PUD. 2. PROVIDE A METER BASE PER LOCAL UTILITY STANDARDS. MOUNT ON SIDE OF OWNER FURNISHED BACK BOARD. 3. UNDERGROUND CONDUIT SHALL BE RIGID POLYVINYL CHLORIDE CONDUIT: SCHEDULE 40, TYPE 1, CONFORMING TO UL ARTICLE 651: WESTERN PLASTICS OR CARLON MANUFACTURER. COUPLINGS SHALL BE SLIP-ON, SOLVENT SEALED T PIPE: SOLVENT, WESTERN TYPE COMPATIBLE WITH PVC DUCT. ALL BENDS SHALL BE "WIDE SWEEP" TYPE WITH A 24" MINIMUM RADIUS. ALL CONDUIT UNDER ROADS SHALL BE RGS, (OR PVC ENCASED IN 8"z18" RED CONCRETE DUCTBANK). 4. CONDUIT USED INDOORS SHALL BE E.M.T., AND RIGID GALVANIZED STEEL FOR OUTDOORS. COUPLINGS SHALL BE RIGID STEEL AND COMPRESSION TYPE FOR E.M.T. SET SCREW FITTINGS ARE NOT PERMITTED. FOR ALL STUBS -UPS, USE RIGID GALVANIZED STEEL CONDUIT. 5. WIRE AND CABLE SHALL BE OF THE TYPE AND SIZE AS REQUIRED BY NEC. THERE WILL BE NO SPLICES ALLOWED. PROVIDE HDPE PULLING HAND HOLES AS NEEDED. 6. CONTRACTOR SHALL PROVIDE TEST OF THE GROUNDING SYSTEM BY CERTIFIED TESTING AGENT. PROVIDE INDEPENDENT TEST RESULTS TO THE PROJECT MANAGER FOR REVIEW. GROUNDING SYSTEM RESISTANCE TO GROUND SHALL NOT EXCEED 5 OHMS. ALL ABOVE GRADE INTERIOR GROUNDING CONNECTORS SHALL BE DOUBLE -LUG COMPRESSION TYPE. ALL BELOW GRADE AND EXPOSED EXTERIOR GROUNDING CONNECTIONS TO PERMANENT EQUIPMENT AND FIXED BUILDING ELEMENTS SHALL BE CADWELD TYPE. CARE SHALL BE TAKEN TO REVIEW CONNECTION LOCATIONS AND MATERIAL TYPES TO AVOID POSSIBLE GALVANIC CORROSION. ALL EXPOSED GROUNDING CONNECTIONS TO BE COATED WITH ANTI -CORROSIVE AGENT SUCH AS "NO -OXY", "NOAOLX" OR "PENETROX". VERIFY PRODUCT WITH PROJECT MANAGER. ALL BOLTS, WASHERS AND NUTS USED ON GROUNDING CONNECTIONS SHALL BE STAINLESS STEEL. 7. ALL EXTERIOR GROUND BARS SHALL BE COATED WITH ANTI -CORROSIVE AGENT SUCH A5 LPS-3 OR AS PER NOTE 6 ABOVE. 8. ALL JUNCTION AND OUTLET BOXES TO BE LABELED WITH KROY TAPE, OR EQUAL, DESIGNATING ALL CIRCUIT NUMBERS CONTAINED IN EACH 80X. 9. CONTRACTOR TO ENSURE ILC PROVIDED WITH (2) INTERNAL LASS. 10. CONTRACTOR SHALL COORDINATE WITH SITE SURVEY TO LOCATE EXISTING UNDERGROUND UTILITIES. WHEREVER POTENTIAL CONFLICTS/ INTERFERENCES EXIST, HAND EXCAVATE TO AVOID DAMAGE. CONTACT ALL UTILITIES TO LOCATE UNDERGROUND PIPING IN PUBLIC ROW. 11. VERIFY THAT A.I.C. OF THE UTILITY DOES NOT EXCEED THE A.I.C. RATING OF THE PROVIDED EQUIPMENT SHELTER PACKAGE. IF OVER 10KAIC, PROVIDE FUSIBLE SERVICE ENTRANCE SWITCH AND CONFIRM LOWERING OF AIC TO ACCEPTABLE LEVELS. 12. UTILITY POINTS OF SERVICE AND WORK / MATERIALS SHOWN ARE BASED UPON PRELIMINARY INFORMATION PROVIDED BY THE UTILITY COMPANIES AND ARE FOR BID PURPOSES ONLY. 13. CONTRACTOR SHALL COORDINATE WITH UTILITY COMPANY FOR FINAL AND EXACT WORK / MATERIALS REQUIREMENTS AND CONSTRUCT TO UTILITY COMPANY ENGINEERING PIANS AND SPECIFICATIONS ONLY. CONTRACTOR SHALL FURNISH AND INSTALL ALL CONDUIT, PULL ROPES, CABLES, PULL BOXES, CONCRETE ENCASEMENT OF CONDUIT (IF REQUIRED), TRANSFORMER PAD, BARRIERS, POLE RISERS, TRENCHING, BACKFILL, PAY ALL UTILITY COMPANY FEES AND INCLUDE ALL REQUIREMENTS IN SCOPE OF WORK. GENRAL NOTES 22"X34" SCALE: NTS 11" X 1T' SCALE: NTS 3 ABBREVIATIONS AWG BCW DWG EMT GEN IGR AMERICAN WIRE GAUGE BARE COPPER WIRE DRAWING ELECTRICAL METALLIC TUBING GENERATOR INTERIOR GROUND RING (HALO) 1.n.11n) (Y�1 UNDERGROUND RACEWAY IMC MGB PCS RGS RWY TYP INTERMEDIATE METALLIC CONDUIT MASTER GROUND BAR PERSONAL COMMUNICATION SYSTEM RIGID GALVANIZED STEEL RACEWAY TYPICAL - - GROUND CONDUCTOR FUSED DISCONNECT PANELBOARD TRANSFORMER FUSED DISCONNECT O FEEDER KEY D LOCAL DISCONNECT GROUND PANELBOARD METER -1, ELECTRICAL I EQUIPMENT L____J ENCLOSURE ELECTRICAL SERV! WEATHERHEAD OGROUND ROD ■ EXOTHERMIC WELD • COMPRESSION TYPE CONNECTION TELEPHONE SERVICE WEATHERHEAD ONE -LINE DIAGRAM 22" X34" SCALE: NTS 11" X 1T' SCALE: NTS 1 LEGEND/ABBREVIATIONS 22"X34" SCALE: NTS 11 X1T SCALE NTS OC CAMP+ ASSOCIATES 19401 40TH AVE. W., SUITE 304 LYNNWOOD, WA 98036 PHONE: (425) 740-6390 FAX: (425) 224-1814 W W W.CAMPASSOC.COM DATE: 7/23/14 DRAWN BY: GA CHECKED BY: EJC REVISIONS REV.: DATE: DESCRIPTION: BY: pQ 7/23/17 ISSUED FOR PRELIM PERMIT GA SITE SOUTHCENTER MALL 2800 SOUTHCENTER MALL SEATTLE, WA 98188 SHEET TITLE ONE -LINE DIAGRAM SHEET NUMBER E-1.0 • KEY NOTES. CONTRACTOR SHALL PROVIDE 6" SQUARE JUNCTION BOX O MOUNTED TO STRUCTURE ABOVE. ROUTE 6#10 & 1#10G -1"C TO PANEL AND CIRCUIT AS SHOWN. CONTRACTOR SHALL PROVIDE FLEXIBLE BRANCH CIRCUIT CONNECTION DOWN TO RECTIFIER RACK WITH 3#10 & 1#10G-3/4" C. PROVIDE VERTICAL SUPPORT FOR BRANCH CIRCUIT. KEY NOTES. 0 EXISTING MAIN CO GROUND BAR MOUNTED TO WALL PROVIDE #6 GREEN INSULATED STRANDED CONDUCTOR WITH 22 CRIMPED MECHANICAL CONNECTOR AT EACH END TO GROUND SECTIONS OF CABLE TRAY TO NEW GROUND BAR. PROVIDE #6 COPPER INSULATED STRANDED CONDUCTOR FROM 0. CONNECTION AT NEW GROUND BAR TO TWO HOLE CRIMPED MECHANICAL LUG AT NEW TELECOMMUNICATIONS EQUIPMENT. OEXISTING INTERIOR GROUND BAR AT WAVE GUIDE ENTRY AT WALL L. J1 I IM— —,r—,r—i--,r—rir--r--r--r =IIIl_ II JLit 11 I: 11 II Y _ JL_JL...IL__LL__LL_ _LL L —J1 L J r --I I I ATT -,12_,41.6,8 I n—TYPICAL— I I: I it u JI CA r� frl -J I L L J ,r�r —irtr— IL1 II:1 LJW ar �r 1 J J rr L—/ J J I' 1 1LL 1 1 LL_V .LL.. LL __ LL ELECTRICAL POWER PLAN F r. n I I. 12 (1111 Ilk L JI I-1I'r-,r-,r-,r-r7- rJi LL_JL_JL-.J _JL_JL_JL_J. - F L J rr 1 / 11--¶--TI--11--¶--1r-1t-1r-Tr _14r --Ir 1r1r1r `Ir —Ir,,'w__r_-7—7--r--u--1--1--11— —11--11— —11--11' II 11 11 II.u___JLj.!..-._1L_.0 2 1.—JL—IJ-LJ—IL L_,ILJL_—IL__11 —_11__6__L__8--11__JI_ L 3 +1 lr —_J 7 22' X34" SCALE: 3/8".1'.0 1" x 1r SCALE: 3/16".1'-O" 1 I L_ L.4 » it /�f1 / 1r/-1 , IL J Ir 1 \ 1 \ \ \ \ \ \ \ N rt I I� rte Ir, r—,r— V JL._F__JL 6 ELECTRICAL GROUNDING PLAN r1R _ _ i! _ _ - -11--11--F-711-7,- 11-- T -- T. - -T- - n- 11 1 II Il LL __u. L li L __l. V. V li ll V �y�pF T11v7KWitA j$Ep 082016 PERMIT CENTER 12 22" X 34" SCALE: 3/6" =1'0" " x 17" SCALE: 3/16" 6 1'0" OC CAMP+ ASSOCIATES 19401 40TH AVE. W., SURE 304 LYNNWOOD, WA 98036 PHONE: (425) 740-6390 FAX: (425) 224-1614 W W W.CAMPASSOC.COM DATE: 7/23/14 DRAWN BY: GA CHECKED BY: EJC REVISIONS REV.: DATE: DESCRIPTION: BY: Qp 7 /23/17 ISSUED FOR PRELIM MIT GA SITE SOUTHCENTER MALL 2800 SOUTHCENTER MALL SEATTLE, WA 98188 SHEET TITLE ELECTRICAL POWER & GROUNDING PLANS SHEET NUMBER E-2.0 1. ALL ELECTRICAL WORK SHALL BE PERFORMED IN ACCORDANCE WITH THE DESIGN AND CONSTRUCTION SPECIFICATIONS AND ALL APPLICABLE LOCAL CODES. 2. ALL GROUNDING SHALL CONFORM TO THE CURRENT VERIZON WIRELESS STANDARDS. 3. CONDUIT ROUTINGS ARE SCHEMATIC. CONTRACTOR SHALL INSTALL CONDUITS SO THAT ACCESS TO EQUIPMENT IS NOT BLOCKED. 4. THE CONTRACTOR IS RESPONSIBLE FOR PROPERLY SEQUENCING GROUNDING AND UNDERGROUND CONDUIT INSTALLATION AS TO PREVENT ANY LOSS OF CONTINUITY IN THE GROUNDING SYSTEM OR DAMAGE TO THE CONDUIT. 5. PREFABRICATED SHELTER WILL BE PROVIDED WITH INTERNAL WIRING AND EQUIPMENT INSTALLED. FOR COMPLETE INTERNAL WIRING AND ARRANGEMENT REFER TO DRAWINGS PROVIDED BY SHELTER MANUFACTURER. 6. FOR INTERIOR EQUIPMENT LAYOUT AND LOCATION, SEE SHELTER MANUFACTURER'S DRAWINGS AND SPECIFICATION. IN CASE OF CONFLICT THE DRAWINGS GOVERN. 7. ALL GROUND CONNECTIONS BELOW GRADE SHALL BE EXOTHERMIC (CADWELD). 8. ALL GROUND CONNECTIONS ABOVE GRADE (INTERIOR & EXTERIOR) SHALL BE FORMED USING TWO (2) HIGH PRESS CRIMPS. 9. ALL EXOTHERMIC CONNECTIONS TO THE GROUND RODS SHALL START AT THE TOP & HAVE A VERTICAL SEPARATION OF 6" FOR EVERY ADDITIONAL CONNECTION. 1D. ALL GROUNDING CONNECTORS TO BE CLEAN AND FREE OF PAINT AT THEIR MATING SURFACES AND INSTALL PER MANUFACTURER'S RECOMMENDATIONS. ALL EXTERIOR GROUND CONNECTIONS SHALL BE COATED WITH A CORROSION RESISTANT MATERIAL. 11. ALL EXTERIOR GROUND CONDUCTORS SHALL BE #2 AWG TIN PLATED COPPER UNLESS OTHERWISE INDICATED. 12. GROUND RODS SHALL BE STAINLESS STEEL OR COPPER CLAD STEEL, 3/4"0 10—FT. LONG, AND SHALL BE DRIVEN VERTICALLY WITH THEIR TOPS 18" BELOW FINAL GRADE OR 6" BELOW FROST LINE FOR MAXIMUM DEPTH. 13. CONNECTIONS TO THE GROUND BUS SHALL NOT BE DOUBLED UP OR STACKED. BACK TO BACK CONNECTIONS ON OPPOSITE SIDES OF THE GROUND BUS ARE PERMITTED. 14. USE OF 90' BENDS IN THE PROTECTION GROUNDING CONDUCTORS SHALL BE AVOIDED WHEN 45' BENDS CAN BE ADEQUATELY SUPPORTED. 15. GROUND RING SHALL BE LOCATED A MINIMUM OF 24" BELOW GRADE OR 6" MINIMUM BELOW THE FROST UNE. 16. INSTALL GROUND CONDUCTORS AND GROUND ROD MINIMUM OF 1'-0" FROM EQUIPMENT CONCRETE PAD, SPREAD FOOTING, OR FENCE. 17. EXOTHERMIC WELD GROUND CONNECTION TO FENCE POST: TREAT WITH A COLD GALVANIZED SPRAY. 18. OBSERVE N.E.C. AND LOCAL UTILITY REQUIREMENTS FOR ELECTRICAL SERVICE GROUNDING 19. GROUNDING ATTACHMENT TO TOWER SHALL BE AS PER MANUFACTURER'S RECOMMENDATIONS OR AT GROUNDING POINTS PROVIDED (2 MINIMUM) 20. MAXIMUM RESISTANCE OF THE COMPLETED GROUND SYSTEM SHALL NOT EXCEED 5 OHMS. 21. MINIMUM BENDING RADIUS FOR GROUNDING CONDUCTORS IS 8" WHEN BENDING IS NECESSARY. GROUND CONDUCTORS ARE TO BE AS STRAIGHT AS POSSIBLE. 22. N0 SPLICES PERMITTED IN GROUND CONDUCTORS. 23. ENSURE ALL MECHANICAL CONNECTORS ARE TORQUED TO THE MANUFACTURER'S SPECIFIED VALUES. 24. GROUND BARS SHALL NOT BE FIELD MODIFIED. 25. ALL HORIZONTAL FENCE SECTIONS TO 8E GROUNDED WITH 8" SINGLE BARREL GROUND STRAPS. 26. USE PANI SCHEME FOR LOADING ON MGB AS DISCUSSED IN NSTD 119, 33 & 36. EXTERNAL TOOTHEAD 3/8"0x1 1/2" S/S NUT 5/S LOCK WASHER S/S FLAT WASHER INSPECTION WINDOW REQUIRED FOR ALL INTERIOR TWO—HOLE CONNECTORS BUTT CONDUCTOR INSULATION UP AGAINST THE CONNECTOR BARREL I CLEAR HEAT SHRINK TINNED COPPER oiscoeeev CLEAR GROUNDING BAR HEAT S/S FLAT WASHER SHRINK S/S BOLT (1 OF 2) "DO NOT DISCONNECT" TAG ON ALL GROUND BAR INTERCONNECTS AND EQUALIZERS #2 AWG (GREEN) COPPER STRANDED WIRE Z.P. STL. CABLE CLAMP 4„ - 20 SCREW WITH LOCK WASHER CLAMP CABLE RACK GROUNDING GENERAL NOTES 22" X 34" SCALE: NTS 11"X1T'SCALE: NTS 1 LUG CONNECTION 22" X 34" SCALE: NTS 11" X ir SCALE: NTS 2 CABLE TRAY GROUNDING 22"X34" SCALE: NTS w 11"X 1T' SCALE: NTS 3 n 0 00 OOO0000000000000 a 0 Loi COAXIAL CABLE GROUNDING KITS W/ 2 HOLE COMPRESSION LUGS (TYP.). SEE DETAIL "B -B" FOR CONNECTION INFORMATION LONG BARREL COMPRESSION LUGS WITH (2) 5/16" BOLTS AND LOCK WASHERS WITH #2 AWG INSULATED STRANDED JUMPER FROM WAVEGUIDE PLATE. 4' X 20" X 1/4" THICK TINNED COPPER GROUND BAR (HARGER GBI 14420ATT) STANDOFF INSULATOR MOUNTING BRACKET (HARGER #84150-A4 OR EOUAL) STAINLESS STEEL MOUNTING BRACKETS (HARGER #WBKT-1 OR EQUAL) #2 AWG TINNED SOLID BARE COPPER CONDUCTOR DOWNLEAD CADWELD TO GROUND BAR WITH FINAL CADWELD CONNECTION TO GROUND RING STRANDED CU WIRE WITH GREEN, 600V, THHN/THWN INSULATION. SIZE AS SPECIFIED TWO -HOLE LUG, BOLTED TO GROUND BAR USING 3/8"-16 x 1 1/4"STAINLESS STEEL HEX HEAD BOLTS AND HARDWARE. GROUND BAR ON WALL, FLOOR OR ON ANTENNA TOWER CAD WELD WITH #2 AWG SOLID TINNED BARE CU WIRE OR STRANDED CU WIRE WITH GREEN, 600V, THHN/THWN INSULATION TO ANTENNA STRUCTURE, BUILDING, RING GROUND OR MGB f GROUND BARS AT BOTTOM OF TOWERS OR MONOPOLES SHALL USE EXOTHERMIC CONNECTION. PANI SCHEME SPECIFICATIONS: pRODUCFR (P) CONNECTS TO WIRELESS EQUIPMENT CABINETS, CABLE ENTRANCE GROUND BAR (CEGB), MAIN DISTRIBUTION FRAME GROUND BAR (MDFB), AND STANDBY ENGINE -GENERATOR SET FRAME AND OTHER NOISE PRODUCING EQUIPMENT ABSORBER (A) CONNECTS TO THE EARTH ELECTRODE SYSTEM INCLUDING CENTRAL OFFICE GROUND GRID, BUILDING STRUCTURAL GROUND, METALLIC WATER PIPE SYSTEM, ANTENNA SUPPORTING STRUCTURE GROUND SYSTEM, AND ELECTRICAL SERVICE ENTRANCE GROUND NON -ISOLATED (N) CONNECTS TO EQUIPMENT NOT IN AN ISOLATED GROUND ZONE (IGZ) SUCH AS CBN EQUIPMENT FRAME GROUNDS AND DC GROUND CONDUCTORS FOR DC POWER SYSTEMS THAT SERVE CBN OR BOTH CBN AND IBN EQUIPMENT ISOLATED (I) CONNECTS TO THE SINGLE POINT CONNECTION BAR (SPCB), FOR IBN EQUIPMENT NOTES: 1. DO NOT INSTALL CABLE GROUND KIT AT A BEND AND ALWAYS DIRECT GROUND WIRE DOWN TO ANTENNA GROUND BAR 2. WEATHER PROOFING SHALL BE ANDREWS. (TYPE & PART NUMBER AS SUPPLIED OR RECOMMENDED BY CABLE MANUFACTURER) MASTER GROUND BAR DETAIL 22" X 34" SCALE: NTS 11'• X 1T' SCALE: NTS 4 ROF TUKWILA CITY SE? 0 8 2016 ;61ear •i,.� (((C CAMP+ ASSOCIATES 19401 40TH AVE. W., SUITE 304 LYNNWOOD, WA 98036 PHONE: (425) 740-6390 FAX: (425) 224-1814 WWW.CAMPASSOC.COM DATE: 7/23/14 DRAWN BY: GA CHECKED BY: EJC REVISIONS REV.: DATE: DESCRIPTION: BY: 7/23/17 ISSUED FOR PRELIM PERMIT GA SITE SOUTHCENTER MALL 2800 SOUTHCENTER MALL SEATTLE, WA 98188 SHEET TITLE GROUNDING DETAILS SHEET NUMBER E-3.0 2/1/2017 City of Tukwila Department of Community Development AARON FRIEDT 13430 NE 177TH PL WOODINVILLE. WA 98072 RE: Permit No. D16-0248 AT & T 344 SOUTHCENTER MALL Dear Permit Holder: Allan Ekberg, Mayor Jack Pace, Director In reviewing our current records, the above noted permit has not received a final inspection by the City of Tukwila Building Division. Per the International Building Code, International Mechanical Code, Uniform Plumbing Code and/or the National Electric Code, every permit issued by the Building Division under the provisions of these codes shall expire by limitation and become null and void if the building or work authorized by such permit has not begun within 180 days from the issuance date of such permit, or if the building or work authorized by such permit is suspended or abandoned at any time after the work has begun for a period of 180 days. Your permit will expire on 3/14/2017. Based on the above, you are hereby advised to: 1) Call the City of Tukwila Inspection Request Line at 206-438-9350 to schedule for the next or final inspection. Each inspection creates a new 180 day period, provided the inspection shows progress.. -or- 2) Submit a written request for permit extension to the Permit Center at least seven(7) days before it is due to expire. Address your extension request to the Building Official and state your reason(s) for the need to extend your permit. The Building Code does allow the Building Official to approve one extension of up to 180 days. If it is determined that your extension request is granted, you will be notified by mail. In the event you do not call for an inspection and/or receive an extension prior to 3/14/2017, your permit will become null and void and any further work on the project will require a new permit and associated fees. Thank you for your cooperation in this matter. Sincerely, Rachelle Ripley Permit Technician File No: D16-0248 6300 Southcenter Boulevard Suite #100 • Tukwila, Washington 98188 • Phone 206-431-3670 • Fax 206-431-3665 PERMIT COORD COPY.. PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: D16-0248 DATE: 09/08/16 PROJECT NAME: AT & T SITE ADDRESS: 344 SOUTHCENTER MALL X Original Plan Submittal Response to Correction Letter # Revision # before Permit Issued Revision # after Permit Issued DEPARTMENTS: 3lilTdmg Divtston ori /gym- rico Public Works ,441 Nik Q�)--1,co Fire Prevention iPp Structural MS. NSA- ?—r Planning Division Permit Coordinator PRELIMINARY REVIEW: Not Applicable ❑ (no approval/review required) DATE: 09/13/16 Structural Review Required REVIEWER'S INITIALS: DATE: ❑ APPROVALS OR CORRECTIONS: Approved Corrections Required n (corrections entered in Reviews) Notation: Approved with Conditions Den ied (ie: Zoning Issues) 3-e a DUE DATE: 10/11/16 n REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping 0 PW 0 Staff Initials: 12/18/2013 PIONEER COMMUNICATIONS C',LC Home Espanol of Contact Safety & Health Claims & Insurance 0 Washington State Department of Labor & Industries Search L&I Page 1 of 2 A -Z Index help My L&I Workplace Rights Trades & Licensing PIONEER COMMUNICATIONS GP LLC Owner or tradesperson Principals PIERCE, BRANT, PARTNER/MEMBER DAUGHTRY, MICHAEL C, PARTNER/MEMBER NESS, TED (THEODORE) G, PARTNER/MEMBER PIERCE, NATHAN ASHER, PARTNER/MEMBER (End: 12/13/2011) LANGE, MATTHEW G, PARTNER/MEMBER (End: 12/17/2013) Doing business as PIONEER COMMUNICATIONS GP LLC WA UBI No. 602 973 461 PO Box 569 WOODINVILLE, WA 98072 425-481-5500 KING County Business type Limited Liability Company Governing persons BRANT R PIERCE MATTHEW G LANGE; MIKE C DAUGHTRY; NATHAN A PIERCE; THEODORE G NESS; License Verify the contractor's active registration / license / certification (depending on trade) and any past violations. Construction Contractor Active. ....................................................................... Meets current requirements. License specialties GENERAL License no. PIONECG903BO Effective — expiration 01/13/2010— 01/13/2018 Bond ............... CBIC Bond account no. SE8187 $12,000.00 Received by L&I Effective date 01/13/2010 01/01/2010 Expiration date Until Canceled Insurance 0,303 Help us improve https://secure.lni.wa.gov/verify/Detail.aspx?UBI=602973461 &LIC=PIONECG903BO&SAW= 9/15/2016