Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Permit D16-0254 - CASH & CARRY - REROOF
CASH & CARRY 230 ANDOVER PARK E EXPIRED 04/08/18 DI 6-0254 Parcel No: Address: City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-438-9350 Web site: http://www.TukwilaWA.gov DEVELOPMENT PERMIT 0223100100 Permit Number: D16-0254 230 ANDOVER PARK E Project Name: CASH & CARRY Issue Date: 9/26/2016 Permit Expires On: 3/25/2017 Owner: Name: Address: Contact Person: Name: STEVE BOZORTH Phone: (253) 797-8048 Address: 25924 78 AVE S , KENT, WA, 98032 Contractor: Name: FIELDS ROOF SERVICE INC Phone: (253) 852-4974 MINKLER ASSOCIATES LLC 3326 106TH AVE SE STE #150 , BELLEVUE, WA, 98008 Address: 25924 78TH AVE S , KENT, WA, 98032 -7364 License No: FIELDRS262L1 Expiration Date: 9/25/2017 Lender: Name: SMART & FINAL STORES LLC Address: PO BOX 512377 , LOS ANGELES, CA, 90040 DESCRIPTION OF WORK: TAR OFF EXISTING ROOF TO WOOD SUBSTRATE, MECHANICALLY ATTACHFIRE RATED BASE SHEET, TWO LAYERS POLY ISO INSULATION, AND INSTALL 060 TPO ROOF MEMBRANE Project Valuation: $81,690.00 Type of Fire Protection: Sprinklers: YES Fire Alarm: YES Type of Construction: VB Electrical Service Provided by: TUKWILA Fees Collected: $2,252.66 Occupancy per IBC: M Water District: TUKWILA Sewer District: TUKWILA Current Codes adopted by the City of Tukwila: International Building Code Edition: International Residential Code Edition: International Mechanical Code Edition: Uniform Plumbing Code Edition: International Fuel Gas Code: 2015 2015 2015 2015 2015 National Electrical Code: WA Cities Electrical Code: WAC 296-46B: WA State Energy Code: 2014 2014 2014 2015 Public Works Activities: Channelization/Striping: Curb Cut/Access/Sidewalk: Fire Loop Hydrant: Flood Control Zone: Hauling/Oversize Load: Land Altering: Landscape Irrigation: Sanitary Side Sewer: Sewer Main Extension: Storm Drainage: Street Use: Water Main Extension: Water Meter: Volumes: Cut: 0 Fill: 0 Number: 0 No Permit Center Authorized Signature: Date: e://c2-/(S ' I hearby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this development permit and agree to the conditions attached to this permit. Signature: Print Name: S-ctr _ 60To c'ff Date: 7/Z6/ /6 This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: ***BUILDING PERMIT CONDITIONS*** 2: Work shall be installed in accordance with the approved construction documents, and any changes made during construction that are not in accordance with the approved construction documents shall be resubmitted for approval. 3: All permits, inspection record card and approved construction documents shall be kept at the site of work and shall be open to inspection by the Building Inspector until final inspection approval is granted. 4: All construction shall be done in conformance with the Washington State Building Code and the Washington State Energy Code. 5: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of this requirement. 6: Prior to final inspection for this building permit, a copy of the roof membrane manufacturer's warranty certificate shall be provided to the building inspector. 7: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 1700 BUILDING FINAL** 0612 EXT ROOFING INSUL 0103 PRE-REROOF CITY OF TUK, LA Community Development Department Public Works Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.TukwilaWA.gov Building Permit No. Project No. Li Date Application Accepted: Date Application Expires: For o 7 ice use onl CONSTRUCTION PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **Please Print** SITE LOCATION Site Address: c:,3 V A-404er Part 6r1u King Co Assessor's Tax No.: 0 10 00 7509 Tenant Name: CA-ScuYtk. Ckrr-y Suite Number: PROPERTY OWNER Name: ©B pr.vper Tr. LLC 601‘11 r-7 Address: PO p Ox D Z City: 9 I% e k /e-- State A Zip: g001 CONTACT PERSON — person receiving all project communication ((�� Name: V� EO )Z-1" 14 Address: Z 91 z.,./..i 70,1144e, S . City: r�i e State: L5...)t _ Zipg803Z I, Phone: Z5 3 — 77 7 _ go 4a : Email:s 5 '' f €-i& `o&FSserJ ice - 6-001 GENERAL CONTRACTOR INFORMATION Company Name:c 161 n 3 Q _o f se.,U IGC'. Address: --1,501 2„)..1 `7g h, 41re- ,s Company Name: City: (/ State' 1 rt W Zip:14 0 3z Z _'7 J/ Fax: Phone:263 , g5 Contr Reg No, e.),,Qs r Z62 Li Exp Date: Address: Tukwila Business License No.: H:Wpplications\Forms-Applications On Line\2012 Applications'Permit Application Revised - 2-7-12.docx Revised: February 2012 hh Floor: New Tenant: ❑ Yes Z.. No ARCHITECT OF RECORD Name CT A FlevtA s%ortZ LL Address: po sox 512_ 377 Company Name: Architect Name: Address: City: State: Zip: Phone: Fax: Email: ENGINEER OF RECORD Name CT A FlevtA s%ortZ LL Address: po sox 512_ 377 Company Name: Engineer Name: Address: City: State: Zip: Phone: Fax: Email: LENDER/BOND ISSUED (required for projects $5,000 or greater per RCW 19.27.095) Name CT A FlevtA s%ortZ LL Address: po sox 512_ 377 City: (.�St ski State: 04 Zip:100j/ Page 1 of 4 BUILDING PERMIT INFORMATIr - 206-431-3670 Valuation of Project (contractor's bid price): $ �� `" ��"�" Existing Building Valuation: $ 2., 500 060 Describe the scope of work (please provide detailed information): V588(ca-d-c42-c-C /41e -ft Will there be new rack storage? ❑ .... Yes If yes, a separate permit and plan submittal will be required. Provide All Building Areas in Square Footage Below PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Will there be a change in use? 0 Yes Standard: FIRE PROTECTION/HAZARDOUS MATERIALS: Compact: Handicap: No If "yes", explain: ❑ Sprinklers ❑ Automatic Fire Alarm 0 None 0 Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes �'Z .... No If `yes', attach list of materials and storage locations on a separate 8-1/2"x I1 "paper including quantities and Material Safety Data Sheets. SEPTIC SYSTEM 0 On-site Septic System — For on-site septic system, provide 2 copies of a current septic design approved by King County Health Department. H:\Applications\Forms-Applications On Line\2012 Applications'Permit Application Revised - 2-7-12.docx Revised: February 2012 bh Page 2 of 4 Existing Interior Remodel Addition to Existing Structure New Type of Construction per IBC Type of Occupancy per IBC lat Floor 2nd Floor 3rd Floor Floors thru Basement Accessory Structure* Attached Garage Detached Garage Attached Carport Detached Carport Covered Deck Uncovered Deck PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Will there be a change in use? 0 Yes Standard: FIRE PROTECTION/HAZARDOUS MATERIALS: Compact: Handicap: No If "yes", explain: ❑ Sprinklers ❑ Automatic Fire Alarm 0 None 0 Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes �'Z .... No If `yes', attach list of materials and storage locations on a separate 8-1/2"x I1 "paper including quantities and Material Safety Data Sheets. SEPTIC SYSTEM 0 On-site Septic System — For on-site septic system, provide 2 copies of a current septic design approved by King County Health Department. H:\Applications\Forms-Applications On Line\2012 Applications'Permit Application Revised - 2-7-12.docx Revised: February 2012 bh Page 2 of 4 PUBLIC WORKS PERMIT INF( IATION — 206-433-0179 Scope of Work (please provide detailed information): Call before you Dig: 811 Please refer to Public Works Bulletin #1 for fees and estimate sheet. Water District ❑ .. Tukwila ❑ ...Water District #125 ❑ .. Water Availability Provided Sewer District ❑ .. Tukwila 0 .. Sewer Use Certificate ❑... Highline 0 ...Valley View ❑ ... Renton ❑ ...Sewer Availability Provided ❑... Renton ❑... Seattle Septic System: 0 On-site Septic System — For on-site septic system, provide 2 copies of a current septic design approved by King County Health Department. Submitted with Application (mark boxes which apply): ❑ .. Civil Plans (Maximum Paper Size — 22" x 34") ❑ .. Technical Information Report (Storm Drainage) El.. Bond 0...Insurance 0... Easement(s) Proposed Activities (mark boxes that apply): ❑ .. Right-of-way Use - Nonprofit for less than 72 hours 0 .. Right-of-way Use - No Disturbance ❑ .. Construction/Excavation/Fill - Right-of-way 0 Non Right-of-way ❑ ❑ .. Total Cut ❑ .. Total Fill ❑ .. Sanitary Side Sewer ❑ .. Cap or Remove Utilities ❑ .. Frontage Improvements ❑ .. Traffic Control ❑ .. Backflow Prevention cubic yards cubic yar.ds Fire Protection Irrigation Domestic Water ❑... Geotechnical Report ❑ ... Maintenance Agreement(s) ❑ .. Traffic Impact Analysis El.. Hold Harmless — (SAO) ❑ .. Hold Harmless — (ROW) o... Right-of-way Use - Profit for less than 72 hours 0... Right-of-way Use — Potential Disturbance ❑ ... Work in Flood Zone 0... Storm Drainage 0...Abandon Septic Tank ❑... Curb Cut 0... Pavement Cut O ... Looped Fire Line 33 ❑ .. Permanent Water Meter Size (1) ❑ .. Temporary Water Meter Size (1) El.. Water Only Meter Size O .. Sewer Main Extension Public ❑ .. Water Main Extension Public 0 0 WO# WO# WO # Private ❑ Private 0 0...Grease Interceptor El... Channelization 0... Trench Excavation ❑ ... Utility Undergrounding (2) " WO # (3) WO # (2) " WO # (3) " WO # ❑ .. Deduct Water Meter Size FINANCE INFORMATION Fire Line Size at Property Line ❑ .. Water ❑ .. Sewer 0 .. Sewage Treatment Monthly Service Billing to: Name: Number of Public Fire Hydrant(s) Day Telephone: Mailing Address: City State Zip Water Meter Refund/Billing: Name: Mailing Address: Day Telephone: City State Zip H:Wpplications\Forms-Applications On Line\2012 ApplicationsWermit Application Revised - 2-7-12.docx Revised: February 2012 bh Page 3 of 4 PERMIT APPLICATION NOTES — Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OW R OR AUT RIZED Signature: Print Name: ge7-02.1— t/ Mailing Address: 2777/ H:Wpplications\Forms-Applications On Line\2012 Applications\Permit Application Revised - 2-7-12.docx Revised: February 2012 hh Date: 115' // Day Telephone: 2`3 7 l 7 -goy Atic—Sa' fkI74-- po Z City State Zip Page 4 of 4 Cash Register Receipt City of Tukwila DESCRIPTIONS 1 ACCOUNT QUANTITY PermitTRAK PAID $1,393.07 D16-0254 Address: 230 ANDOVER PARK E Apn: 0223100100 $1,393.07 DEVELOPMENT $1,326.95 PERMIT FEE R000.322.100.00.00 0.00 $1,322.45 WASHINGTON STATE SURCHARGE B640.237.114 0.00 $4.50 TECHNOLOGY FEE $66.12 TECHNOLOGY FEE TOTAL FEES PAID BY RECEIPT: R9503 R000.322.900.04.00 0.00 $66.12 $1,393.07 Date Paid: Monday, September 26, 2016 Paid By: FIELDS ROOF SERVICE Pay Method: CHECK 90005 Printed: Monday, September 26, 2016 4:14 PM 1 of 1 CSYSTEMS Cash Register Receipt City of Tukwila DESCRIPTIONS ACCOUNT 1 QUANTITY I PAID PermitTRAK $859.59 D16-0254 Address: 230 ANDOVER PARK E Apn: 0223100100 $859.59 DEVELOPMENT $859.59 PLAN CHECK FEE TOTAL FEES PAID BY RECEIPT: R9428 R000.345.830.00.00 0.00 $859.59 $859.59 Date Paid: Thursday, September 15, 2016 Paid By: FIELDS ROOF SERVICE Pay Method: CHECK 89952 Printed: Thursday, September 15, 2016 4:01 PM 1 of 1 SYSTEMS INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION D/6-625"/ 6300 Southcenter Blvd., #100, Tukwila: WA 98188 Permit Inspection Request Line (206) 438-9350 (206) 431-3670 Project: 1.5/14-- . �tlfi'qief Type of Inspection: , J/cDJNG F//' OL Address: ,30 ANnOtM ANDSPSK E Date Called: Special Instructions: yW void 44'4it- sErVO Date Wanted: /6-10-/7 ca.. --m.'.2% p.m. Requester: Phone No:f Approved per applicable codes. /ElCorrections required prior to approval. COMMENTS: „vo RcsooNCs.1r.A7TFicf1-T)o'/ p ,w 7T inspector: Date:/6.--/e) ate: / ' f� —77 D REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION NO. INSPECTION RECORD Retain a copy with permit 'Nee- ZZst1 PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Pro}}'p�ct: CASH st 6r2r21 Typ5 of Inspection: bo i tbt e,- int' �- Address: AI.E&ry PR4 5 Date Called: Instructions: Date Wanted: S- iii/ 7 S- %% % % a rr p.m •Special p.m. Requester: Phone No: Approved per applicable codes. MCorrections required prior to approval. COMMENTS: PROVIAC Fes» /Y , A'i1 7VRA'S 1,40-R rf e cie-T7rycA-7 Inspector: Date:5- ! 7 REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 (0-- O2s--I Project: spa , CAe.y0Iz6- ape of Inspection: -Ar,�L Address: to 0112K C Date Called: 1 viv�f`r Asdb. A w S PCA -ter' 0ii S ur6 JA Special Instructions: -C12'S &f 2P4 Date Wanted: l2l6n terry, Requester: Phone No: ElApproved per applicable codes. g Corrections required prior to approval. COMMENTS: 6Approved Inspector: .14b414,1 REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. 1 viv�f`r Asdb. A w S PCA -ter' 0ii S ur6 JA 7-) PrziA/ i - e- nu -C12'S &f 2P4 g/caeKT, T7oA/ Inspector: .14b414,1 REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project: Type of Inspection: Address:r, .2-0? e► AAmcn/ PACK e Date Called: Special Instructions: Date Wanted: //U fG p.m. Requester. Phone No: Approved per applicable codes. a Corrections required prior to approval. COMMENTS: eAAirrzu Pete coAnimermis A/0 )23 4 -v Inspector: n REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. 0./ INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project: SA (/ eAde `/ Ty of Inspection: l C- VEs12c-6r Address: (dr/ 4 i iv *leeCr Date Called: Special Instructions: Date Wan����%l6. Requester: � 'v,�yim Phone No: z<-3 # CC C2--66 7q ® Approved per applicable codes. L, Corrections required prior to approval. COMMENTS: Inspector: Date: /6 n REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. REVISIONS No changes shall ho made to the scope of wo-k i^";tho,;t prior approval of F3u''ding Division NOT:: w it require a new plan submittal and may inc ude additional plan review fees. // rn co W L a) 0 -do2a2 CSC !rei © �Sy Plan review approval is subs t• erro , and omissions. Approval of construction documen z s not authorize the vi dation of any adopted code or ord nance. Receipt of approved Feld Co and conditions is acknowledged: By: Date: C/ 1744h City of Tui; ! UILDIR9G DIM= Cash & Carry Bldg - 230 Andover Pk E SEPARATE. RJ TE PERMIT RECU,ED FOR: �1 chanicai LSI Electrical IirFlumbing las Piping City of Tukwila BUILD:NG DIVISION Awning ) Poa Bu!p$ti1 O O Scale: 1 inch = 27 feet 185'-0" REVIEWED FOR 11 CODE COMPLIANCE APPROVED SEP 2 2 2016 City d 'ukvAts: UILDING DIVISION lb Uo'O uesuejsuyo RECEIVED CITY OF TUKWILA SEP 15 2016 ERMIT CENTER IV ever Park E im ezeId JOluaai OS m cya 0 e' m G) Q. -c ca - CO xi st O c cs M )Jed Jaopuy M *IJed Janopud oo rri {m 3 tae Janapu+ Andover Park E C z "410 a. CO 03 JO rem Suen3 azaaag eu tieg sebum PUM wipe Auld el!wir. 0 c :::° piu { to Xr ek 4. �. rra ES ea 0 010 Z M—d"6., m 01) ton tgo fie CO 10. 3 )}Jed{ .JaA0PUV sn r. o m 6 0 s' Fp 0 a) tv e)0 "r41'4' -,z -(f) O 1 ; _ 1 to n 4 4 0 REVIEWED FOR CODE COMPLIANCE APPROVED SEP 2 2 2016 City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA SEP 15 2016 PERMIT CENTER Cash and Carry Roof Replacement 230 Andover Park East Tukwila, WA 98188 riL rnw• Fields Roof Service of Kent, WA proposes to tear off the existing multi -layer built up roof system at 230 Andover Park East, Tukwila, WA. The roof will be removed down to the wood substrate. We will then mechanically fasten one layer of Carlisle FR -10 fire rated base sheet, two layers of Carlisle 2.6" poly iso insulation with Rhinobond plates and Carlisle HP -X Screws fastened at Carlisle Specifications. We will then install Carlilse 060 TPO in grey and heat weld to Rhinobond plates and all seams per manufactures specifications. We will fully adhere Carlisle 060 TPO in grey up and over the walls and cap the walls with an exterior fastened 24ga cap metal. All materials will be Carlisle since this is a Carlisle 20 year NDL warranty and will be inspected. System is a Class B fire rated system. ply- REVIEWED FOR CODE COMPLIANCE APPROVED SEP 2 2 2016 City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA SEP 15 2016 PERMIT CENTER REVIEWED FOR CODE COMPLIANtt APPROVED ;s SEP 2 2 2016 City' of Tukwila wila rittiinieskt UED KWILA SEP 15 2016 PERMIT CENTER SYSTEM FEATURES AND BENEFITS INCLUDE: • Reduces fasteners, plates and labor • No perimeter sheets required • Faster dry -in time • Non -penetrating system • Symmetrical wind Toad distribution 800-479-6832 • P.O. Box 7000 • Carlisle, PA 17013 • Fax: 717-245-7053 • www.carlislesyntec.com SYNTEC SYSTEMS EnducTan RhinoBond is an alternative attachment system for Carlisle's Sure -Weld® TPO, Spectro-WeldTM TPO, Sure-FIexTM PVC or Sure -Flex PVC KEE membranes. This all -in -one system uses the same fastener and plate to secure the membrane and the insulation to the deck without penetrating the roofing membrane. The result is a Factory Mutual -approved system that does not create any point of entry for moisture, requires fewer fasteners and provides superior wind uplift performance compared to standard mechanically attached TPO systems. RhinoBond plates are positioned in a grid -type or in-line pattern on the substrate and secured with mechanical fasteners to the deck. Carlisle's TPO or PVC membrane is laid into position and the seams are hot-air welded. No fasteners in the seams are required. The RhinoBond induction welding tool is placed on the membrane surface directly above each of the RhinoBond plates. The tool activates the special coating, resulting in a bond between the plates and the membrane. The weighted magnets are then placed over the plates to dissipate heat and ensure intimate contact between the bottom surface of the membrane and the hot -melt adhesive. Czn[coIId Productivity By eliminating mechanical fastening in the seam, Carlisle's RhinoBond system decreases the number of screws and plates required for some assemblies by as much as 50%. This reduction results in minimized labor and material costs. Spacing the RhinoBond plates in a grid -type pattern more evenly distributes the wind load and allows the use of full -width sheets across the entire roof area, eliminating the need for narrow perimeter sheets and reducing the number of seam welds. The Carlisle RhinoBond system results in faster dry -in and allows the roofing applicator to tackle more square feet each day without the added concern of disrupting activities inside the building due to potential inclement weather. Cm0rov d PeKormance The evenly distributed securement provided by the RhinoBond system reduces wind flutter and noise as well as membrane fatigue compared to traditional mechanically attached assemblies. The plates are adhered to the underside of the membrane, creating a non -penetrating assembly. The induction technology the patented RhinoBond tool utilizes has been in use since the 1990's and performs well under various weather conditions. The tool is effective even when the membrane is wet. Cdeam For IfiJetam [ etrolit Pzpmications The Carlisle RhinoBond system is a great solution for metal retrofit applications. Unlike traditional assemblies, RhinoBond plates and fasteners are not required to be located in the seam area, eliminating the need for purlin-width sheets. This not only improves productivity but also reduces waste and increases profitability. Fasteners and Mates The RhinoBond system includes 3 -inch round specially coated plates, sold in pails of 500. RhinoBond plates meet FM 4470 criteria for corrosion resistance and can be installed with a variety of Carlisle fasteners. Cnduct on 12a:ding i'®oi The RhinoBond tool is lightweight, with an adjustable and easy-to-use handle. It operates on standard 110 -volt power sources and typically draws 1,300 watts. A 5,000 -watt generator in good condition with two 20A GFCI protected circuits will run two tools. 800-479-6832 • P.O. Box 7000 • Carlisle, PA 17013 • Fax: 717-245-7053 • www.carlislesyntec.com Sure -Weld, Sure -Flex and Spectra -Weld are trademarks o1 Carlisle. RhinoBond is a registered trademark of OMG, Inc. REPRINT CODE: 605176-'RhinoBond Sell Sheet" - 050812 ® 2012 Carlisle. SYNTEC SYSTEMS EXPERIENCE THE CARLISLE DIFFERENCE G4RLIHLE SYNTEC SYSTEMS I SecurShieId HD POLYISO Insulation Overview Carlisle's SecurShield HD Polyiso Insulation is a rigid roof insulation panel composed of a high-density, closed -cell polyisocyanurate foam core laminated to a premium -performance, coated glass fiber -mat facer. Suitable for both re -roofing and new construction applications, SecurShield HD is specifically designed for use as a cover board over a variety of substrates. SecurShield HD delivers an R -value of 2.5, which is significantly higher than roof cover boards made with other materials such as wood fiber or gypsum. Features and Benefits » High-density insulating cover board » Compressive strength of 100 psi » Lightweight and easy to cut, handle, and install » Exceptional protection against hail, rooftop traffic, mold, and moisture » High-density formulation achieves FM severe hail rating (SH) » 5 times higher R -value than gypsum cover boards 2 times higher R -value than wood fiber boards One-fifth the weight of gypsum cover boards » Compatible with all Carlisle single -ply roofing systems (Except Ballast) » Coated glass facer provides strong bond for adhered roofing applications Product Characteristics Panel sizes: - 4' x 8' (1220 mm x 2440 mm) - 4' x 4' (1220 mm x 1220 mm) Panel thickness:' h" (13 mm) » Weight: 0.343 lbs/sq. ft. - 11 lbs (4.99 kg) per 4' x 8' panel - 5.5 lbs (2.49 kg) per 4' x 4' panel Installation Mechanically Attached Single -Ply Systems Each SecurShield HD panel must be secured to the substrate with approved Carlisle fasteners and plates. Butt edges and stagger joints of adjacent panels. Install the roof membrane according to Carlisle specifications. Fully Adhered Single -Ply Systems Carlisle's SecurShield HD may be secured to the roof deck using Carlisle's FAST" and Flexible FAST adhesive, OlyBond500® insulation adhesive, fasteners and plates, or hot asphalt (appropriate to the deck type). For adhesive coverage or fastening patterns and requirements, please contact Carlisle's Design Services group. Butt the edges of the insulation panels and stagger the joints. Be certain to install boards with the proper side down, as indicated on each board. Install the membrane according to Carlisle specifications. Review Carlisle specifications and details for complete installation information. Code Approvals » FM 4450 and FM 4470 » UL 790 » UL Classified Precautions Insulation must be protected from open flame and kept dry at all times. Install only as much insulation as can be covered the same day by completed roof -covering material. Carlisle will not be responsible for specific building and roof design, for deficiencies in construction or workmanship, for dangerous conditions on the jobsite, or for improper storage and handling. Technical specifications shown in this literature are intended to be used as general guidelines only and are subject to change without notice. Call Carlisle for more specific details or refer to PIMA Technical Bulletin No. 109: Storage and Handling Recommendations for Polyiso Roof Insulation. 800-479-6832 I P.O. Box 7000 1 Carlisle, PA 17013 I Fax: 717-245-7053 I www.carlislesyntec.com EXPERIENCE THE CARLISLE DIFFERENCE ISecurShield HD POLYISO Insulation Typical Properties Physical Property and Characteristics Test Method Value Compressive Strength ASTM D1621 (modified) 100 psi (690 kPa) Dimensional Stability ASTM D2126 <0.5% linear change (7 days) Water Absorption ASTM C209 <1% volume R -value ASTM C518 2.5 Thickness '/2" Service Temperature 260°F (126°C) or less Resistance to Mold ASTM D3273 Passed Typical properties and characteristics are based on samples tested and are not guaranteed for all samples of this product. This data and information is intended as a guide and does not reflect the specification range tor any particular property o1 this product. LEED° Information Pre -consumer Recycled Content 0% . Post -consumer Recycled Content Manufacturing Locations Smithfield, PA Franklin Park, IL Tooele, UT Montgomery, NY Lake City, FL Terrell, TX, Puyallup, WA I Solar Reflectance Index (SRI) N/A Other Polyiso Products by Carlisle n Flat and Tapered HP -H — Polyiso bonded to fiber -reinforced paper facers n Flat and Tapered SecurShield — Polyiso bonded to coated glass facers n SecurShield CD —1" Class A Polyiso on a combustible deck n HP -NB — Polyiso bonded to oriented strand board n HP -F — Polyiso bonded to foil n SecurShield HD Composite - Polyiso bonded on-line to a' h" SecurShield HD Coverboard n SecurShield HD Plus —'/2" Polyiso coverboard, 100 psi — FM 1-90 with reduced fastening 10.23.14 C 2014 Carlisle. REPRINT CODE: 605075 - "SecurShield HD Polyiso Product Data Sheet" CARL/.SLE SYNTEC SYSTEMS 800-479-6832 I P.O. Box 7000 I Carlisle, PA 17013 I Fax: 717-245-7053 1 www.carlislesyntec.com Carlisle, SecurShield, Flexible FAST and FAST are trademarks of Carlisle. OlyBond500 is a registered trademark of OMG. LEED is a registered trademark of the U.S. Green Building Council. EXPERIENCE THE CARLISLE DIFFERENCE IHP -H POLYIS Insulation G4RL151E SYNTEC SYSTEMS HP -H Polyiso Thermal Values Thickness Thickness (inches) (MM) 1.00 25 1.50 38 LTTR R -value** 5.7 Flute Spanability 2%" 8.6 4W Overview HP -H is a rigid -roof insulation panel composed of a closed -cell polyisocyanurate foam core bonded on each side to fiber -reinforced paper facers. Features and Benefits • HP -H polyiso insulation provides the highest R -value per inch of commercially available insulation products A Environmentally friendly construction with 0% ozone-depleting components and CFC free a Approved for direct application to steel decks Panel Characteristics A Available in 4' x 4' (1220 mm x 1220 mm) and 4' x 8' (1220 mm x 2440 mm) panels in thickness of 1" (25 mm) to 4.5" (115 mm) b Available in two grades of compressive strengths per ASTM C1289-11, Type II, Class 1, Grade 2 (20 psi), Grade 3 (25 psi) Applications » Constructions requiring FM Class 1 and UL Class A ratings X. Single -Ply Roof Systems (Ballasted, Mechanically Attached, Fully Adhered) 3.80 97 22.3 4 %" 4.00 102 23.6 4%" 4.30 109 25.5 4.50 114 26.8 4%" 4%" "Long -Term Thermal Resistance Values are based on ASTM C1289-11 effective January 1, 2014, predicting product R -value after five years, which is equivalent to a time -weighted thermal design R -value for 15 years. Installation Ballasted Single -Ply Systems Each HP -H panel is loosely laid on the roof deck. Butt edges and stagger joints of adjacent panels. Install the roof membrane according to Carlisle's specifications. Mechanically Attached Single -Ply Systems Each HP -H panel must be secured to the roof deck with fasteners and plates (appropriate to the deck type). Butt edges and stagger joints of adjacent panels. Install the roof membrane according to Carlisle's specifications. Fully Adhered Single -Ply Systems Each HP -H panel must be secured to the roof deck with fasteners and plates (appropriate to deck type). Butt edges and stagger joints of adjacent panels. Install the roof membrane according to Carlisle's specifications. HP -H 4' x 8' panels can be secured to the roof deck with Carlisle's FAST® Adhesive, either full coverage or bead spacing of no less than 6" on center. HP -H 4' x 4' panels may be adhered to prepared concrete deck with a full mopping of Type III or IV asphalt. Review Carlisle specifications and details for complete installation information. 800-479-6832 1 P.O. Box 7000 1 Carlisle, PA 17013 I Fax: 717-245-7053 I www.carlislesyntec.com • nr :Da cz, 1-7LaD L\ 7)) OC. DPrv-a7-io { Overview Carlisle HP -X Fasteners are used with Carlisle's TPO or PVC RhinoBond Fastening Plates to secure Sure -Weld® TPO and Sure-Flexim PVC roofing membranes. The HP -X Fastener is used on 20 -gauge (0.91 mm) or 22 -gauge (0.76 mm) steel or wood decks (minimum 15/32" [12 mmj CDX plywood). The HP -X Fastener is designed to offer an optimum combination of driving performance, back -out and corrosion resistance with excellent pullout values. The RhinoBond TPO or PVC Fastening Plate is designed to attach the roofing membrane from the underside using the RhinoBond induction -welding tool. Features and Benefits • Reduces the number of fasteners and plates compared with conventional mechanically attached applications • No perimeter sheets required • Faster dry -in time • Non -penetrating system • Symmetrical load distribution Installation No pre -drilling is necessary for wood and steel decks. Simply insert the HP -X Fastener through the Carlisle RhinoBond plate and install with a standard clutch drive electric screw gun (0-2500 rpm). Optimum fastener performance is achieved when the fastener is installed perpendicular to the deck and into the top flutes of a steel deck. Follow RhinoBond System installation instructions to attach the membrane to the installed plate using the RhinoBond portable induction tool. Keep insulation substrate and membrane clean: Any debris on the top of the insulation substrate and/or the membrane should be removed prior to initiating the bonding process. Use a leaf blower or broom to eliminate any debris from the membrane surface. Keep magnets clean: If a metal shard or other debris from the roof sticks to the magnet, it can cause damage to the membrane surface in the weld area. Periodically ensure there are no contaminants on the bottom side of the magnet. Precautions 1. Eye protection is recommended during installation. 2. Use care to avoid over -torquing the fastener. 3. Do not expose plates to UV for extended periods. Fasteners RhinoBond Typical Properties and Characteristics* Plates Size loch (mm) Weight/Ctn (Kg) Thread Length Inch (mm) 2(50) 20bs(9.1) Full Padmgng Fasteners/Ctn. 1,000 3 (80) 29 bs (13.1) 3 (75) 1,000 4 (110) 38 be (17.2) 4 (100) 1,000 5 (130) 47 613(21.3) 4 (100) 1,000 6 (150) 56 Os (25.4) 4 (100) 1,000 7 (175) 33 ba (15.0) 4 (100) 500 8 (20D) 38 Ke(172) 4 (100) 500 10 (250) 46 lbs (20.9) 4 (100) 500 12 (300) 55 bs (24.9) 4 (100) 500 14 (355) 65 lbs (29.5) 4 (100) 500 Plates 31%e (80) 361bs (16.0) — 500 Steel Deck 22 Gauge or 20 Gauge Wood Deck Win. 15/32• Typical Pull-out Value Minimum Penetration 710 lb! (3158 N) 22 gauge 3Gi(19mm) 375 bf (1668 N) 1• (25 mm) Mardmum Penetration Typical Static Back -out 4" (100 mm) 4" (100 mm) 15.1 In lbs (1.7 N -m) N/A Typical Drill Times 1.5 seconds - 20 gauge N/A * Typical properties and characteristics are based on samples tested and are not guaranteed for all samples of this product. This data and information is intended as a guide and does not reflect the specification range for any particular property of this product. 800-479-6832 • P.O. Box 7000 • Carlisle, PA 17013 • Fax: 717-245-7053 • www.carlislesyntec.com Carlisle, HP -X Fasteners, Sure -Flex and Sure -Weld are trademarks of Carlisle. RhinoBond Is a registered trademark of OMG, Inc. REPRINT CODE: 605836 -'HP-X Fasteners and Rhtno0ond Plate Product Data Sheet' - 08.20.12 0 2012 Carlisle. BYNTEC SVSTEMex Overview Overview The FR Base Sheet is a tough non -asphaltic fiberglass -based underlayment that meets or exceeds ASTM D226 or D4869 Type I or II performance. In conjunction with the Hot Mopped System, the FR Base Sheet can be incorporated to provide a suitable substrate for deck types requiring a fastened base. FR Base Sheet is the Ideal substrate for direct applications of the Hot Mopped System or Mechanically Fastened System over decks manufactured from wood, tectum, gypsum, and lightweight concrete. Required fasteners for each deck type as well as the fastening density are outlined in Carlisle's Specification. Features and Benefits • Excellent fire resistance for wood decks • Base Sheet lays down flat • Non -slip surface during installation • Tan color provides cooler working surface • Carlisle warranty coverage of product Ratings for Hot Mopped Adhered AFX Systems FR Base Sheet also provides an economical alternative for applications requiring additional fire resistance over combustible decks. The integration of a single layer of the FR Base Sheet under the Hot Mopped AFX membrane provides a UL Class B rating. When two layers of FR Base Sheet are installed over a combustible deck the assembly can achieve a UL Class A rating with the direct application of Carlisle's Sure -Seal® Hot Mopped AFX. The UL Class A and B ratings extend up to lh" in 12" for applications over plywood. Fire Ratings for Mechanically Fastened Systems Contractors frequently encounter applications where additional fire resistance is required under mechanically fastened systems. For Carlisle Mechanically Fastened Sure -Seal or Sure -Weld® roofing systems, the FR Base Sheet product can be incorporated as an underlayment to enhance fire ratings. Significant labor savings can be achieved with this option as no additional fastening is required other than the seam fastening. When comparing installations requiring board stock, this product can save time when cutting in around penetrations to provide significant reductions in labor. A UL Class A rating can be achieved with 2 layers of FR Base Sheet with our Sure -Seal or Sure - Weld Mechanically Fastened Roofing Systems. For Carlisle Sure -Seal or Sure -Weld Systems applied over combustible %2" plywood decks, the following UL Ratings can be achieved. Base UL Ratings Rating moo -m Ratings UL Class A UL Class B Mechanically Fastened Sure -Seal 1" max - 2 layers 14" max -1 layer Mechanically Fastened Sure -Weld Adhered AFX Sure -Seal Adhered AFX Sure -Weld Ya" max - 2 layers 14" max - 2 layers N/A W max -1 layer 14" max -1 layer 14" max -1 layer !Typical Properties and Characteristics Specifications Rot Size 250' (length) 48" (width) Test Method ASTM D146 Area Per Roll 1,000 ft= min ASTM D146 Rog Weight 96 lbs ASTM D146 Tensile Breaking Strength, (Ib/1" width) MD 54 min CD 24 min D828 Liquid Water Transmission Test PASS ASTM 04869 Typical properties and characteristics are based on samples tested and are not guaranteed for all samples of this product. This data and Information is intended as a guide and does not reflect the specification or specification range for any particular property of this product. LEED® Information Pre -consumer Recycled Content 0% Pre -consumer Recycled Content 0% Manufacturing Location Meridian, MS 800-479-6832 • P.O. Box 7000 • Carlisle, PA 17013 • Fax: 717-245-7053 • www.carlislesyntec.com Carlisle, ReeceBACK, Sure -Seal and Sure -Weld are trademarks al Carlisle. LEED is a registered trademark of the United States Building Council. REPRINT CODE: 601469 -'FR Base Sheet 1S Product Data Sheet' - 091812 0 2012 Carlisle. BYNTEC 8Y07 -EMS EXPERIENCE THE CARLISLE DIFFERENCE ISure -Weld' TPO Reinforced Membrane Overview Carlisle's Sure -Weld TPO reinforced membrane is a premium, heat - weldable, single -ply thermoplastic polyolefin (TPO) sheet designed for new roof construction and re -roofing applications. Sure -Weld High Slope (HS) membrane is formulated with additional flame retardant for higher -slope fire code approvals. Sure -Weld EXTRA is 80 mils thick for significantly higher strength and weatherability. Sure -Weld TPO membranes use advanced polymerization technology that combines the flexibility of ethylene -propylene (EP) rubber with the heat weldability of polypropylene. All Sure -Weld TPO membranes include OctaGuard XT`", an industry-leading, state-of-the-art weathering package. OctaGuard XT technology enables Sure -Weld TPO to withstand the extreme weatherability testing that is intended to simulate exposure to severe climates. Physical properties of the membrane are enhanced by a strong polyester fabric that is encapsulated between the TPO-based top and bottom plies. The combination of the fabric and TPO plies provides high breaking and tearing strength, as well as excellent puncture resistance. The relatively smooth surface of the membrane produces a total surface fusion weld that results in a consistent, watertight, monolithic roof assembly. The membrane is environmentally friendly and safe to install. Carlisle's Sure -Weld TPO reinforced membrane is available with APEEL Protective Film, saving time and labor by eliminating the need for roof cleaning upon project completion. Carlisle's innovative APEEL Protective Film can be left in place for up to 90 days without affecting the integrity of the film, guarding the TPO membrane's surface from scuffs and dirt accumulation during installation. Durable and easy to remove, APEEL Protective Film improves aesthetics and long-term reflectivity and is ideal for re -roofing, re-cover, and new construction projects. G4RL/5LE SYNTEC SYSTEMS Carlisle's standard and HS TPO membranes are available in highly reflective white, tan, and gray, in both 45 -mil and 60 -mil thicknesses. 80 -mil Sure - Weld EXTRA (including HS) is also offered in white, gray, and tan colors. Sixteen special colors are also available (see Carlisle's TPO Color Palette brochure). Carlisle's TPO is offered in 4-, and 6 -ft perimeter sheets and 8-,10-, and 12 -ft field sheets. Carlisle's tan and white TPO membranes are ENERGY STAR®* -qualified and California Title 24 compliant and can contribute toward LEED® (Leadership in Energy and Environmental Design) credits. Features and Benefits » Outstanding puncture resistance Chlorine -free with no halogenated flame retardants Plasticizer -free; does not contain liquid or polymeric plasticizers » Excellent resistance to impact and low temperatures » » Excellent chemical resistance to acids, bases and restaurant exhaust emissions UL 2218 Class 4 hail rating Exceptional resistance to heat, solar UV, ozone and oxidation Manufactured using a hot -melt extrusion process for complete scrim encapsulation 100% recyclable (see Carlisle's Recyclability Statement) Enhanced with the OctaGuard XT weathering package » APEEL Protective Film application guards the TPO membrane's surface from scuffs and dirt accumulation during installation, improving the roof system's appearance and long-term performance » APEEL Protective Film can be left in place for up to 90 days without degrading due to its excellent heat- and UV -resistance •f, OCTRGURRO XT WEATHERING PACKAGE , r I PROTECTIVE FILM 800-479-6832 I P.O. Box 7000 I Carlisle, PA 17013 I Fax: 717-245-7053 I www.carlislesyntec.com EXPERIENCE THE CARLISLE DIFFERENCE ISure -Weld 4p Reinforced Membrane Installation 1. Sure -Weld TPO roofing systems are quick to install, as minimal labor and few components are required. TPO systems are installed using an Automatic Heat Welder, making sheet welding fast, clean, consistent, and easy to (earn, while reducing strain on the roofing technician. 2. APEEL Protective Film should be removed from within areas that are to be heat -welded together. In areas that do not require heat - welding, the APEEL Protective Film can be left in place for up to 90 days. When the installation of the entire TPO roofing system is complete, remove and discard the APEEL Protective Film. 3. The Carlisle Mechanically Fastened Roof System installation starts by fastening the insulation with a minimum of 4 fasteners per 4' by 8' board. The membrane is mechanically fastened to the deck using HP -X" Fasteners and Piranha Plates" or HP-XTRA Fasteners and Piranha XTRA Plates. Adjoining sheets of membrane are overlapped over the fasteners and plates and joined together with a minimum 11/2" -wide (4 cm) hot-air weld. Typical Properties and Characteristics Physical Property ASTM D6878 Requirement 45 -mil 60 -mil 80 -mil EXTRA Tolerance on Nominal Thickness, % ASTM 0751 test method +15, -10 ± 10 ± 10 ± 10 Thickness Over Scrim, In. (mm) ASTM 07635 optical method, average of 3 areas 0.015 min (0.380) 0.018 typical (0.457) 0.024 typical (0.610) 0.034 typical (0.864) Breaking Strength, Ibf (kN) ASTM 0751 grab 220 (976 N) min 225 (1.0) min 320 (1.4) typical 250 (1.1) min 360 (1.6) typical 350 (1.6) min 425 (1.9) typical Elongation Break of Reinforcement, % ASTM D751 grab method 15 min 15 min 25 typical 15 min 25 typical 15 min 25 typical Tearing Strength, Ibf (N) ASTM 0751 proc. B 8 in. x 8 in. 55 (245) min 55 (245) min 130 (578) typical 55 (245) min 130 (578) typical 55 (245) min 130 (578) typical Brittleness Point, °F (°C) ASTM D2137 _ -40 (-40) max -40 (-40) max -50 (-46) typical -40 (-40) max -50 (-46) typical -40 (-40) max -50 (-46) typical Linear Dimensional Change, % ASTM D1204, 6 hours at 158°F ± 1 max ± 1 max -0.2 typical ±1 max -0.2 typical ± 1 max -0.2 typical Ozone Resistance, no cracks 7X ASTM D1149, 100 pphm, 168 hrs PASS PASS PASS PASS Water Absorption Resistance, mass % ASTM 0471 top surface only 166 hours at 158°F water ± 3.0 max ± 3.0 max 0.90 typical ± 3.0 max 0.90 typical ± 3.0 max 0.90 typical Factory Seam Strength, Ibf/in (kN/m) ASTM 0751 grab method 66 (290) min 66 (290) min 66 (290) min 66 (290) min Field Seam Strength, Ibfln (kN/m) ASTM D1876 tested in peel No requirement 25 (4.4) min 50 (8.8) typical 25 (4.4) min 60 (10.5) typical 40 (7.0) min 70 (12.3) typical Water Vapor Permeance, Perms ASTM E96 proc. B No requirement 0.10 max 0.05 typical 0.10 max 0.05 typical 0.10 max 0.05 typical Puncture Resistance, Ibf (kN) FTM 101 C, method 2031 (see supplemental section) No requirement 250 (1.1) min 325 (1.4) typical 300 (1.3) min 350 (1.6) typical 400 (1.8) min 450 (2.0) typical Properties After Heat Aging ASTM D573, 5376 hours ® 240°F Breaking strength Elongation Reinf. Tearing Strength Weight Change, % 198 (881) 90% min 13.5 (90%) min 33 (60%) min ± 1.0 max 205 (912) min 13.5 min 33 min 1.0 max 225 (1000) min 13.5 min 33 min 1.0 max 315 (1400) min 13.5 min 33 min 1.0 max Typical Weights Ib/ft2 (kg/m2) 0.23 (1.1) 0.29 (1.4) 0.40 (2.0) Typical properties and characteristics are based on samples tested and are no guaranteed for all samples of this product. This data and information is intended as a guide and does not reflect the specification range for any particular property of this product. • ISure -Weld TP Reinforced Membrane 4. The Carlisle Fully Adhered Roofing System installation begins by fastening the insulation at the required density necessary to meet the appropriate warranty or wind load requirement. The substrate and membrane are then coated with an appropriate Sure -Weld TPO bonding adhesive and the membrane is rolled into place. Review Carlisle specifications and details for complete installation information. Precautions » Sunglasses that filter out ultraviolet Tight are strongly recommended, as tan and white surfaces are highly reflective. Roofing technicians should dress appropriately and wear sunscreen. » Surfaces may become slippery due to frost and ice buildup. Exercise caution during cold conditions to prevent falls. » Care must be exercised when working close to a roof edge when the surrounding area is snow-covered, as the roof edge may not be clearly visible. » Use proper stacking procedures to ensure sufficient stability of the rolls. » Exercise caution when walking on wet membrane. Membranes may be slippery when wet. » Store membrane in the original undisturbed plastic wrap in a cool, shaded area and cover with Tight -colored, breathable, waterproof tarpaulins. Membrane That has been exposed to the weather must be prepared with Weathered Membrane Cleaner prior to hot-air welding. » Take care not to stand or place heavy objects on the edge of folded - over membrane, as this could cause a hard crease in the membrane. » Maximum sustained temperature not to exceed 160°F (71°C) for TPO membrane. » Do not use razor blades or other sharp tools to cut the APEEL Protective Film while it is still adhered to the TPO membrane as damage to the underlying membrane may occure. Pull the protective film away from the membrane prior to cutting. » Remove APEEL Protective Film by pulling towards the center of the roof. Do not remove the film by pulling towards the roof edge. EXTREME Testing for Severe Climates ASTM Standard D6878 is the material specification for Thermoplastic Polyolefin -Based Sheet Roofing. It covers material property requirements for TPO roof sheeting and includes initial and aged properties after heat and xenon -arc exposure. As stated in the scope of the standard, "the tests and property limits used to characterize the sheet are values intended to ensure minimum quality for the intended purpose." Carlisle's goal is to G4RL15LE SYNTEC SYSTEMS produce TPO that delivers maximum performance for the intended purpose of roofing membranes. Maximum performance requires the membrane to far exceed the requirements of ASTM D6878. Heat Aging accelerates the oxidation rate that roughly doubles for each 18°F (10°C) increase in roof membrane temperature. Oxidation (reaction with oxygen) is one of the primary chemical degradation mechanisms of roofing materials. Carlisle Testing - Heat Aging ASTM Requirement Sure -Weld Requirement ASTM TEST 32 weeks* 52 weeks 240°F *Comparable to 1,024 weeks (20 years) at 185°F for 6 hours/day. » Test specimen is a 1" by 4" piece of 45 -mil membrane unbacked, placed in circulating hot-air oven. » Criterion — no visible cracks after bending aged test specimen around 0.25" -diameter mandrel. Xenon -arc exposes the membrane samples to the combined effect of UV, visible and infrared radiation as well as ozone, heat and water spray to greatly accelerate the effects of outdoor weathering. The radiation dose is measured in kilojoules per square meter (kJ/m2) at 340 nm machine UV wavelength. The irradiance power of the xenon -arc lamp is measured in watts per square meter (W/m2). Carlisle Testing - Xenon -Arc Sure -Weld Results ASTM TEST ASTM D6878 45 -mil 60 -mil 80 -mil Requirement kJ/m2 at 340 nm j 10,080 17,640 20,160 27,720 » Test specimen is a 2.75" by 5.5" piece of membrane, unbacked, weathering side facing arc lamp. » Criterion — no visible cracks when viewed under 1 Ox magnification while wrapped around 3" -diameter mandrel. 800-479-6832 I P.O. Box 7000 I Carlisle, PA 17013 I Fax: 717-245-7053 I www.carlislesyntec.com EXPERIENCE THE CARLISLE DIFFERENCE ISure -Weld TPO Reinforced Membrane Environmental Cycling subjects the membrane to repeated cycles of heat aging, hot-water immersion, and xenon -arc exposure. n ASTM requirement - none n Carlisle EXTREME test*: - 10 days heat aging at 240°F (116°C) followed by - 5 days water immersion at 158°F (70°C) followed by - 5,040 kJ/m2 (2000 hours at 0.70 W/m2 irradiance) xenon -arc exposure *Test specimen is 2.75" by 5.5" piece of membrane with edges sealed. *Criterion - after 3 complete cycles, test specimens shall remain flexible and not have any cracking under 10x magnification while wrapped around a 3" -diameter mandrel. Supplemental Approvals, Statements and Characteristics: 1. Sure -Weld TPO meets or exceeds the requirements of ASTM D6878 Standard Specification for Thermoplastic Polyolefin -Based Sheet Roofing. 2. Radiative Properties for ENERGY STAR, Cool Roof Rating Council (CRRC) and LEED. 3. Sure -Weld TPO membranes conform to requirements of the US E.P.A. Toxic Leachate Test (40 CFR part 136) performed by an independent analytical laboratory. 4. Sure -Weld TPO was tested for dynamic puncture resistance per ASTM D5635-04 using the most recently modified impact head. 45 - mil was watertight after an impact energy of 12.5 J (9.2 ft-Ibf) and 60 -mil was watertight after 22.5 J (16.6 ft-Ibf). 80 -mil EXTRA was watertight after an impact energy of 30.0 J (22.1 ft-Ibf). G4RL15LE SYNTEC SYSTEMS Radiative Properties for ENERGY STAR*, and LEED Solar Reflectance Index (SRI) is calculated per ASTM E1980. The SRI is a measure of the roof's ability to reject solar heat, as shown by a small temperature rise. It Is defined so that a standard black (reflectance 0.05, emittance 0.90) Is 0 and a standard white (reflectance 0.80, emittance 0.90) is 100. Materials with the highest SRI values are the coolest choices for roofing. Due to the way SRI is defined, particularly hot materials can even take slightly negative values and particularly cool materials can even exceed 100. LEED Information Pre -consumer Recycled Content 10% Post -consumer Recycled Content 0% Manufacturing Location Solar Reflectance Index (SRI) Senatobia, MS Tooele, UT 99 (white) 86 (tan) 800-479-6832 I P.O. Box 7000 I Carlisle, PA 17013 I Fax: 717-245-7053 I www.carlislesyntec.com Carlisle, Sure -Weld, OctaGuard XT, APEEL, Piranha Plates and HP -X are trademarks of Carlisle. ENERGY STAR Is a registered trademark owned by the U.S. Government. *ENERGY STAR qualification Is only valid in the U.S. 1 FFD Is a renlstered trademark of the II. S. Green R"I1dln° Council. 05.28.15 ® 2015 Carlisle. REPRINT CODE: 600515 - "Sure -Weld TPO Reinforced Membrane Product Data Sheet" Test Method White TPO Tan TPO Gray TPO ENERGY STAR - Initial solar reflectance Solar Spectrum Reflectometer 0.79 0.71 N/A ENERGY STAR - Initial solar reflectance after 3 years Solar Spectrum Reflectometer (uncleaned) 0.70 0.64 N/A CRRC - Initial solar reflectance ASTM C1549 0.79 0.71 0.46 CRRC - Solar reflectance after 3 years ASTM C1549 (uncleaned) 0.70 0.64 0.43 CRRC - Initial thermal emittance ASTM C1371 0.90 0.86 0.89 CRRC-Thermal emittance after 3 years ASTM C1371 (uncleaned) 0.86 0.87 0.88 LEED - Thermal emittance PASS 0.90 0.86 0.85 SRI (Solar Reflectance Index) 99 86 53 Solar Reflectance Index (SRI) is calculated per ASTM E1980. The SRI is a measure of the roof's ability to reject solar heat, as shown by a small temperature rise. It Is defined so that a standard black (reflectance 0.05, emittance 0.90) Is 0 and a standard white (reflectance 0.80, emittance 0.90) is 100. Materials with the highest SRI values are the coolest choices for roofing. Due to the way SRI is defined, particularly hot materials can even take slightly negative values and particularly cool materials can even exceed 100. LEED Information Pre -consumer Recycled Content 10% Post -consumer Recycled Content 0% Manufacturing Location Solar Reflectance Index (SRI) Senatobia, MS Tooele, UT 99 (white) 86 (tan) 800-479-6832 I P.O. Box 7000 I Carlisle, PA 17013 I Fax: 717-245-7053 I www.carlislesyntec.com Carlisle, Sure -Weld, OctaGuard XT, APEEL, Piranha Plates and HP -X are trademarks of Carlisle. ENERGY STAR Is a registered trademark owned by the U.S. Government. *ENERGY STAR qualification Is only valid in the U.S. 1 FFD Is a renlstered trademark of the II. S. Green R"I1dln° Council. 05.28.15 ® 2015 Carlisle. REPRINT CODE: 600515 - "Sure -Weld TPO Reinforced Membrane Product Data Sheet" EXPERIENCE THE CARLISLE DIFFERENCE I Sure -Weld i Coated Metal p)ET Overview Sure -Weld TPO Coated Metal is a 24 -gauge (0.6 mm) galvanized steel sheet that is coated with a layer of .035" non -reinforced TPO flashing. TPO membrane may be welded directly to the coated metal, eliminating the need to strip in the metal with a separate piece of TPO Pressure -Sensitive Coverstrip. The sheet is cut to the appropriate width and used to fabricate metal drip edges or other roof perimeter edging profiles. The metal is available in 4' by 10' (1.2 m by 3.1 m) sheets and comes packaged 10 or 25 sheets per pallet. Carlisle's TPO Coated Metal is part of Carlisle's comprehensive TPO accessory offering that meets the stringent quality tolerances required to be included in a Carlisle warranted roofing system. Features and Benefits » Allows direct welding of TPO membrane to the metal, eliminating the need to strip in edging with additional TPO Pressure -Sensitive Coverstrip. Easy to cut and form for creating a variety of edge sizes and profiles. G4RLIHLE SYNTEC SYMTEA40 Installation 1. Install TPO Coated Metal with 1/8" to 1/4" (3-6 mm) between adjoining sections. 2. Install 2" -wide (5 cm) duct tape over joints in TPO Coated Metal. 3. Heat -weld 6" -wide (15.5 cm) piece of TPO non -reinforced flashing over joint. 4. Position TPO reinforced membrane and heat -weld to the TPO Coated Metal with a minimum 11/' (4 cm) weld. Review Carlisle specifications and details for complete installation information. Precautions Store coated metal in a cool, shaded area and cover with light-colored, breathable, waterproof tarpaulins. TPO Coated Metal that has been exposed to the weather must be prepared with Weathered Membrane Cleaner prior to hot-air welding. Typical Properties and Characteristics Sheet Size Weight Color Flashing Thickness Steel Thickness Steel Type 4' by 10' (1.2 m by 3.0 m) 1.1 Ib/ft2 (5.4 kg/m2) Gray, Tan and White 0.035" (0.9 mm) nominal Conforms to ASTM A653 0.024" (0.6 mm) nominal (24 gauge) Hot Dipped Galvanized Steel — 690 Packaging 10 or 25 sheets per pallet Typical properties and characteristics are based on samples tested and are not guaranteed for all samples of this product. This data and information is intended as a guide and does not reflect the specification range for any particular property of this product. LEED® Information Pre -consumer Recycled Content 0% Post -consumer Recycled Content ; 0% Manufacturing Location j Franklin Park, IL Solar Reflectance Index (SRI) N/A 800-479-6832 I P.O. Box 7000 I Carlisle, PA 17013 I Fax: 717-245-7053 I www.carlislesyntec.com 02.26.16 C 2016 Carlisle. Carlisle and Sure -Weld are trademarks of Carlisle. REPRINT CODE: 604820 - "Sure -Weld TPO Coated Metal Product Data Sheet" LEED is a registered trademark of the U.S. Green Building Council. EXPERIENCE THE CARLISLE DIFFERENCE Certified Fabricated Accessory Sure -Weld' 7.7© Roofing System Accessories Sure -Weld Square Tubing Wraps are fabricated using 60 -mil reinforced Sure - Weld membrane and are designed to flash square metal tubing. A split and overlap tab are incorporated into these parts to allow the flashings to be opened and wrapped around a square penetration with an obstruction. Includes pressure -sensitive termination flashing. Sizes Available: 3" x 3", 4" x 4", 5" x 5" and 6" x 6". Other sizes and colors available through special order. Quantity Per Box: 8 2 1 -Sure -Weld TPO Inside Corners 2 -Sure -Weld TPO Outside Corners are pre -molded and are used for flashing inside and outside corners of a variety of details. Quantity Per Bag: 12 3 -Sure -Weld TPO T -Joint Covers are pre -punched non -reinforced flashings used to seal intersections on 60 and 80 -mil TPO membranes. Sizes Available: 4.5" diameter Quantity Per Box: 100 01.05.16 O 2016 Carlisle. REPRINT CODE: 603415 - "TPO Accessories Sheet" Sure -Weld Split Pipe -Seals are fabricated flashings made of 60 -mil reinforced Sure -Weld membrane for flashing pipes with an obstruction that prevents the installation of a molded pipe seal. Includes stainless steel clamping rings. Sizes Available: 1", 2", 3", 4", 5" and 6" diameter. Other sizes and colors available through special order. Quantity Per Box: 8 Sure -Weld Molded Sealant Pockets are interlocking, two piece, injection molded weldable pockets and are used to waterproof pipe clusters or other odd shaped penetrations. Sizes Available: Approximate size is 7th"- 10"x6"x2"high Quantity Per Box: 5 full pockets IZ4RL/SLE SYNTEC SYSTEMS A ready reference guide for ordering TPO Accessories for your next job, Sure -Weld Molded Pipe Seals are injection -molded, pre -formed flashings for pipes.lncludes stainless steel clamping rings. Sizes Available: 3/4" to 8" diameter Quantity Per Box: 8 1110 Sure -Weld Walkway Rolls are designed to protect the Sure -Weld membrane in those areas exposed to repetitive foot traffic and other hazards. Stocked in white, tan and gray, special colors available (minimum quantities apply) Sizes Available: 34" x 50' rolls Quantity Per Box: 1 roll Sure -Weld Pressure -Sensitive Coverstrip is a non -reinforced TPO laminated to a pressure -sensitive tape used for stripping in flat metal flanges such as drip edge. Sizes Available: 6" x 100' Quantity Per Box: 2 rolls Yellow Pressure -Sensitive Warning Strip is a nominal 30 -mil -thick non -reinforced TPO flashing laminated to a nominal 30 -mil thick fully cured synthetic rubber PS adhesive. Yellow PS Coverstrip can be applied to EPDM and TPO roofing systems to provide a visual warning of an impending hazard (i.e. roof edge, deep drain sump, skylight). Sizes Available: 6" x 100' rolls Quantity Per Box: 2 rolls Sure -Weld Pressure -Sensitive RUSS is available in two types. 10" RUSS (shown) is used in place of narrow width sheets to secure membrane in the perimeter of the roof. 6" RUSS is used to secure membrane at the base of vertical walls without penetrating the sheet. Sizes Available: 6" x 100' and 10" x 100' Quantity Per Box: 2 rolls of 6" x 100' and 1 roll of 10" x 100'. Sure -Weld Curb Wrap Corners are fabricated flashings made of 60 -mil reinforced Sure -Weld membrane designed to reduce curb flashing time. Each corner has a 6" wide base flange and a 12" overall height. One curb will require 4 comers. Sizes Available: 7" Wrap for 12" Curb, 13" Wrap for 24" Curb, 19" Wrap for 36" Curb Other sizes and colors available through special orders. Can also be ordered in 1- or 2 -piece wraps. Quantity Per Box: 12 wraps per box or 3 full curbs 800-479-6832 I P.O. Box 7000 I Carlisle, PA 17013 I Fax: 717-245-7053 I www.carlislesyntec.com Carlisle and Sure -Weld are trademarks of Carlisle. EXPERIENCE THE CARLISLE DIFFERENCE Sure -Weld' L Walkway Roils 3 Overview Carlisle's Sure -Weld Heat Weldable Walkway Roll is designed to protect the Sure -Weld TPO membrane in those areas exposed to repetitive foot traffic and other hazards. Walkways must be installed at all traffic concentration points (i.e, roof hatches, access doors, rooftop ladders, etc.) regardless of traffic frequency. Walkways must also be installed if regular maintenance (once a month or more) is necessary to service rooftop equipment. Carlisle Sure -Weld Walkway Rolls are part of the Certified Fabricated Accessory (CFA) program. Certified Fabricated Accessories are the only factory -fabricated TPO accessories that meet the stringent quality tolerances required to be included in a Carlisle warranted roofing system. Features and Benefits Increased slip resistance created with a diamond plate tread pattern Walkway edges are trimmed in safety yellow to better define the designated traffic flow The yellow edges are smooth without tread lugs for easier welding Superior weathering package for long term performance Stocked in white, tan and gray, special colors available (minimum quantities apply) Installation 1. Use Weathered Membrane Cleaner to prepare the membrane to be welded to the walkway material. 2. Position the walkway material. Cut the Walkway Rolls into maximum 10' lengths and position with a minimum 1" gap between adjacent pieces to allow for water drainage. Cut the walkway so a 4" minimum gap is created over any field splices. (Since the attachment of the walkway to the membrane is permanent, this will allow access to the field seams). 04.03.13 ® 2013 Carlisle. REPRINT CODE: 600322 - "TPO Walkway Rolls Product Data Sheet" G4RL/SLE Certified Fabricated Accessory 3. Using an automated welder, weld all four sides of the walkway material to the membrane. (Typically the same speed and temperature settings will be used for this procedure as for welding membrane to membrane. A test weld is always recommended prior to performing welds to the installed membrane). A hand held welder may be utilized, however, productivity will be decreased. Review Carlisle specifications and details for complete installation information. Precautions Walkway Rolls are a maintenance item and are not covered under the Carlisle membrane systems warranty. This product is to be used as a walkway only and is not designed as a perimeter warning line or a substitute for ballast. Walkway rolls cannot be installed within 10' (3m) of the roof perimeter. If possible, allow the walkway to relax and warm up in the sun prior to welding in place. Typical Properties and Characteristics Physical Property Test Method Typical Properties Minimum Maximum Dimensional Conformance ASTM 0412 0.160 (4.06) 0.180 (4.5) Thickness, in. (mm) Density, lbs./ft3; (gr/cm3;) ASTM D792 80.5 (1.29) 84.3 (1.35) Tensile Strength, psi (MPa) ASTM D638 600 (4.1) Tear Strength, lbf/in (kN/m) ; ASTM D624 100 (17.5) Sizes 34" wide x 50' long Packaging 9 per skid, each roll individually bagged Weight (each) Thickness Color 97 lbs. 80 -mil at bottom of tread, 80 -mil at yellow welding edge, 170 -mil overall White, gray and tan Typical properties and characteristics are based on samples tested and are not guaranteed for all samples of this product. This data and information is intended as a guide and does not reflect the specification range for any particular property of this product. 800-479-6832 I P.O. Box 7000 I Carlisle, PA 17013 I Fax: 717-245-7053 I www.carlislesyntec.com Carlisle and Sure -Weld are trademarks of Carlisle. fio EXPERIENCE THE CARLISLE DIFFERENCE SureWekf UFO Outside Corners L- — Overview Let Carlisle simplify your next Sure -Weld TPO installation with prefabricated Outside Corners. Sure -Weld TPO Outside Corners are pre - molded and are used for flashing outside corners on a variety of details. Installation is fast and easy with no cutting or stretching required. Carlisle's Sure -Weld TPO Outside Corners are part of the Certified Fabricated Accessory (CFA) program. Certified Fabricated Accessories are the only factory -fabricated TPO accessories that meet the stringent quality tolerances required to be included in a Carlisle warranted roofing system. Features and Benefits Provide a substantial labor savings compared to field fabricating from non -reinforced flashing Pre -stretched, multi -wave design allows wrapping outside corners that are out of square and not exactly 90 degrees More consistent appearance than outside corners field fabricated from flashing Installation 1. Place the center point of the Sure -Weld TPO Outside Corner over the outside intersection of the corner. 2. Begin welding at the innermost center point and work away from the center by first welding the vertical portion of the flashing. 3. Use a lower temperature setting on the heat welder than when welding reinforced TPO membrane. (Typically a setting of 6 on a scale of 10 is appropriate for welding TPO Outside Corners). 1I IZ4RL/5LE SYNTEC SYSTEMS Certified Fabricated Accessory 4. Use the edge of the roller to crease the corner flashing into any membrane step-off to create a proper seal. 5. Probe all welded edges of the corner only once the material has completely cooled to ensure watertight performance. Review Carlisle specifications and details for complete installation information. Precautions Store TPO Outside Corners in a cool, shaded area and cover with light- colored, breathable, waterproof tarpaulins. TPO Outside Corners or TPO membrane that has been exposed to the weather prior to use must be prepared with Weathered Membrane Cleaner before hot-air welding. Typical Properties and Characteristics Thickness Packaging Color Material 0.060" (1.5 mm) 12 per bag White, Gray, Tan --l.------------ - - Injection -molded TPO _ _ _ Typical properties and characteristics are based on samples tested and are not guaranteed for all samples of this product. This data and information is intended as a guide and does not reflect the specification range for any particular property of this product. LEED® Information Pre -consumer Recycled Content 0% Post -consumer Recycled Content . 0% Manufacturing Location I Bloomingdale, IL Solar Reflectance Index (SRI) N/A — W_Y^ 800-479-6832 I P.O. Box 7000 I Carlisle, PA 17013 I Fax: 717-245-7053 I www.carlislesyntec.com Carlisle and Sure -Weld are trademarks of Carlisle. LEED is a registered trademark of the U.S. Green Building Council. 09.20.13 G, 2013 Carlisle. REPRINT CODE: 604459 - "Sure -Weld TPO Outside Corners Product Data Sheet" 1/ i EXPERIENCE THE CARLISLE DIFFERENCE Sure -Weld' i7CSO Inside Corners Overview Let Carlisle simplify your next Sure -Weld TPO installation with prefabricated Inside Corners. TPO Inside Corners are pre -molded and are used for flashing inside corners on a variety of details. Installation is fast and easy with no cutting or stretching required. Carlisle's TPO Inside Corners are part of the Certified Fabricated Accessory (CFA) program. Certified Fabricated Accessories are the only factory - fabricated TPO accessories that meet the stringent quality tolerances required to be included in a Carlisle warranted roofing system. Features and Benefits 3> Forms easily into "out -of -square" corners that are not exactly 90° Provides substantial labor savings compared to field fabricating the flashing detail from non -reinforced flashing More consistent appearance than inside corners field -fabricated from flashing 03.03.14 © 2014 Carlisle. REPRINT CODE: 602105- "Inside Corners Product Data Sheet" G4RL15LE Certified Fabricated Accessory Installation SYNTEC SYSTEMS 1. Position the TPO Inside Corner into the building corner, begin welding at the innermost corner point and work away from the corner. 2. Use a lower temperature setting on the heat welder than when welding reinforced TPO membrane. (Typically a setting of 6 on a scale of 10 is appropriate for welding TPO Inside Corners). 3. Use the edge of the roller to crease the corner flashing into any membrane step-off to create a proper seal. 4. Probe all welded edges of the corner only once the material has completely cooled to ensure watertight performance. Review Carlisle specifications and details for complete installation information. Precautions » Store TPO Inside Corners in a cool, shaded area and cover with light- colored, breathable, waterproof tarpaulins. TPO Inside Corners or TPO membrane that has been exposed to the weather prior to use must be prepared with Weathered Membrane Cleaner before hot air welding. Typical Properties and Characteristics Thickness 0.060" (1.5 mm) Packaging 12/bag Color White, Gray, Tan Material J Injection molded Typical properties and characteristics are based on samples tested and are not guaranteed for all samples of this product. This data and information is intended as a guide and does not reflect the specification range for any particular property of this product. LEED® Information Pre -consumer Recycled Content 0% r___ Post -consumer Recycled Content [ 0% Manufacturing Location ' Bloomingdale, IL r--- — — . Solar Reflectance Index (SRI) N/A 800-479-6832 I P.O. Box 7000 I Carlisle, PA 17013 I Fax: 717-245-7053 I www.carlislesyntec.com Carlisle and Sure -Weld are trademarks of Carlisle. LEED is a registered trademark of the U.S. Green Building Council. SureWeDcf EFF© Split Pipe Seals Overview Let Carlisle simplify your next Sure -Weld TPO installation with prefabricated Split Pipe Seals. TPO Split Pipe Seals are fabricated flashings made from 60 -mil reinforced TPO membrane for pipes 1" (25.4 mm) to 6" (152.4 mm) in diameter. A split (cut) and overlap tab are incorporated into these parts to allow the pipe seals to be opened and wrapped around a round pipe with an obstruction. Such obstructions prevent the use of a standard pre -molded pipe seal. Split Pipe Seals are packaged in boxes of eight and come with universal clamping rings. Additional sizes and colors are available on a special order basis. Carlisle's TPO Split Pipe Seals are part of the Certified Fabricated Accessory (CFA) program. Certified Fabricated Accessories are the only factory -fabricated TPO accessories that meet the stringent quality tolerances required to be included in a Carlisle warranted roofing system. Features and Benefits » Provides a reliable method of waterproofing round pipe penetrations Provides a substantial labor savings compared to field -fabricating from non -reinforced flashing Provides a more consistent professional appearance than field - fabricated pipe flashings Simplifies the contractor's job when flashing a pipe with an obstruction G4RL15LE SYNTEC SYSTEMS Installation 1. Confirm the outside diameter of the pipe. The following method will ensure that the TPO Split Pipe Seal will be the correct size to complete the detail. The nominal diameter of the indicates the maximum size the part will effectively fit. Each TPO Split Pipe Seal can accommodate a pipe 1" smaller in outside diameter than the nominal size indicates. For example, the 2" part can be utilized to flash pipes from 1'/,e" to 2" in diameter, the 3" part will fit pipes from 21A6" to 3" in diameter, etc. 2. Open TPO Split Pipe Seal by pulling apart the tack welds located on the vertical leg of the flashing. 3. Wrap the TPO Split Pipe Seal around the pipe until the vertical leg is tight against the outside diameter of the pipe. 4. Mark the pipe around the top of the TPO Split Pipe Seal. 5. Remove the TPO Split Pipe Seal from around the pipe. 6. Install Water Cut-off Mastic below the mark, which indicates the top of the installed TPO Split Pipe Seal. 7. Wrap the TPO Split Pipe Seal back around the penetration until the vertical leg is tight against the outside diameter of the pipe. 8. Tack -weld the back edge of the pipe seal's vertical leg ensuring that good contact is maintained between the TPO Split Pipe Seal and the pipe. This process will hold the TPO Split Pipe Seal in place. 9. Heat -weld the entire width of the vertical overlap. Hand roll against the outer surface of the pipe to create the pressure necessary to achieve an acceptable weld. 10. Heat -weld the base flange to the deck membrane and complete the horizontal overlap weld. 11. Once the flashing has completely cooled, check all splices for voids and cold welds. Make any needed repairs. 12. Install a stainless steel universal clamping ring to provide constant compression of the sealant. 13. Apply Cut -Edge Sealant to all edges of the TPO Split Pipe Seal that are located on the horizontal plane. Do not apply the sealant to vertical surfaces. Review Carlisle specifications and details for complete installation information. 800-479-6832 I P.O. Box 7000 I Carlisle, PA 17013 I Fax: 717-245-7053 I www.carlislesyntec.com EXPERIENCE THE CARLISLE DIFFERENCE Sure -Weld Split Pipe Seals Precautions Remove all lead and other flashing. Temperature of pipe must not exceed 160°F (71°C). Install a minimum of four fastening plates around pipe penetrations on mechanically fastened systems. Position fastening plates around the penetration so the plates are covered by the TPO Split Pipe Seal flange. A minimum 11/2" -wide weld must be maintained around the outer edge of the flange beyond the plates. If fastening plates cannot be installed in a manner to allow a minimum 11/2' weld, the plates must be placed outside the pipe seal flange and covered with a heat -welded reinforced TPO overlay. Store pipe seals in a cool, shaded area and cover with light-colored, breathable, waterproof tarpaulins. TPO Split Pipe Seals or membrane that have been exposed to the weather prior to use must be prepared with Weathered Membrane Cleaner prior to hot-air welding G4RL/SLE , YN TEC BYE i E/vlS Typical Properties and Characteristics Sizes 1", 2", 3", 4", 5" and 6" 0.D. Pipe (25.4, 50.8, 76.2,101.6, 127.0 and 152.4 mm) Packaging_ 8/box Weight (box) 1" - 4 lbs (2 kg) 2"-5lbs (2kg) 3" - 5 lbs (2 kg) 4"-6lbs (3kg) 5"-6lbs (3kg) 6"-6lbs (3kg) Material Reinforced 60 -mil TPO membrane Color j White (Gray and Tan are available as a custom order) Typical properties and characteristics are based on samples tested and are not guaranteed for all samples of this product. This data and information is intended as a guide and does not reflect the specification range for any particular property of this product. LEED® Information Pre -consumer Recycled Content ; Post -consumer Recycled Content ' Manufacturing Location Solar Reflectance Index (SRI) 10% Eugene, OR White:99 800-479-6832 I P.O. Box 7000 I Carlisle, PA 17013 I Fax: 717-245-7053 I www.carlislesyntec.com Carlisle and Sure -Weld are trademarks of Carlisle. LEED is a registered trademark of the U.S. Green Building Council. 11.25.13 © 2013 Carlisle. REPRINT CODE: 604554 "Sure -Weld TPO Split Pipe Seals Product Data Sheet" SW TPO CARLISLE'S SURE.WELD® MOLDED SEALANT POCKETS Product Data. Overview Let Carlisle simplify your next Sure -Weld TPO installation with TPO Molded Sealant Pockets. The Carlisle Molded TPO Sealant Pockets consist of an interlocking, two-piece, injection molded flexible pocket with a rigid polypropylene vertical wall and pre -formed deck flanges. Pockets can be adjusted from 11 1/2" to 7 1/2" in length by following the cutting lines molded into the pocket. This product, in conjunction with TPO Primer and White Thermoplastic One -Part Sealant, is used to waterproof pipe clusters or other odd shaped penetrations on Sure -Weld TPO Roofing Systems. Carlisle's Sure -Weld TPO Molded Sealant Pockets are part of the Certified Fabricated Accessory (CFA) program. Certified Fabricated Accessories are the only factory -fabricated TPO accessories that meet the stringent quality tolerances required to be included in a Carlisle warranted roofing system. Intended Uses TPO Molded Sealant Pockets are interlocking, two-piece, injection molded weldable pockets and are used to waterproof pipe clusters or other odd shaped penetrations. Features and Benefits • Provides substantial labor savings compared to field fabricating a sealant pocket from coated metal or other material • Provides a reliable method to permanently waterproof odd shaped penetrations • Size may be enlarged with the use of Sure -Weld Pocket Extensions • Professional finished appearance • Built-in extension legs provide size flexibility • Molded in place cutting lines allows for four different Sealant Pocket sizes Certified Fabricated Accessory Installation 1. Place the TPO Molded Sealant Pocket around the penetration to determine if reduction of size is required (a minimum of 1" from penetration(s) is needed on any side). Pocket may be adjusted in size by cutting the vertical wall and pre -formed deck flange along any of the molded cutting lines. 2. Clean all the areas of the Molded TPO Sealant Pocket that will be welded (along with all inside surfaces), as well as the deck membrane and penetration(s) with Weathered Membrane Cleaner. (Use a Primer Pad with the cleaner if the membrane has been exposed for an extended period of time). 3. Place the Molded TPO Sealant Pocket around penetration(s), overlapping the two sections of the pocket. 4. Cut a piece of cardboard (approx. 4"x4") and place between the overlapping area of the Molded TPO Sealant Pocket and the deck membrane. The cardboard prevents the pocket from welding to the membrane when first welding the overlaps. 5. Using a hand -welder, weld the angle change in overlap area. Using the end of a seam probe assists in this process. (The hand -welder temperature setting should be between 5 and 6). Investing in Roofing Solutions for Over 45 Years 800-4-SYNTEC • P.O. Box 7000 • Carlisle, PA 17013 • Fax: 717-245-7053 • www.carlisle-syntec.com r-Y•L I 1.-11' Carlisle SynTec 4 SW TPO CARLISLE'S SURE -WELD® MOLDED SEALANT POCKETS Product Data. 6. Hand -weld the remainder of the horizontal overlap. 7. Repeat steps 4 and 5 to weld the overlap on the other side of the Molded TPO Sealant Pocket. 8. Position the Molded TPO Sealant Pocket so the vertical overlap is against the penetration. This will allow proper pressure to be applied to the overlap with the 2 -inch silicone roller. 9. Weld both vertical overlaps starting at the angle change and progressing to the top of the pocket. 10. After properly positioning the pocket, make tack -welds on all four sides of the flange to hold it in place during the final welding process. 11. Weld the entire horizontal flange to the deck membrane. 12. Once completely cool, using seam probe, check all splices for voids and cold -welds. Make any needed repairs. 13. Apply a thin coat of TPO Primer to the inside and around the top rim of the pocket, to the deck membrane enclosed by the pocket and to the penetration using a small paint brush. 14. Fill the pocket with sealant. Use an adequate amount of sealant to ensure that contact is made with the top rim of the pocket. Investing in Roofing Solutions for Over 45 Years Precautions 1. Temperature of penetration shall not exceed 160°F (71°C). 2. The inside of the sealant pocket and all penetrations must be cleaned with Weathered Membrane Cleaner then coated with TPO Primer prior to filling with sealant. 3. Carlisle's White Thermoplastic One -Part Sealant must completely fill sealant pocket. 4. The walls of the sealant pocket must be a minimum of one -inch from any penetration. 5. UV filtering sunglasses are strongly recommended when working on Sure -Weld Roofing Systems. 6. Store sealant pockets in a cool, shaded area and cover with light-colored, breathable, waterproof tarpaulins. Pre -Fab Sealant Pockets or membrane that have been exposed to the weather must be prepared with Weathered Membrane Cleaner prior to hot air welding. (Primer pads must be used if the membrane has been exposed for an extended period of time). Molded Sealant Pockets Typical Properties and Characteristics Size: 11.5" - 7.5" by 6" oval (29 cm -19 cm by 15 cm) Packaging: 5 Pockets/Ctn. Weight (each): 0.75 lbs (0.34 kg) Material: Injection Molded TPO Color: White, Gray, Tan 800-4-SYNTEC • P.O. Box 7000 • Carlisle, PA 17013 • Fax: 717-245-7053 • www.carlisle-syntec.com Carlisle and Sure -Weld are trademarks of Carlisle. REPRINT CODE: 601655 - "SW Molded Sealant Pockets Product Data Sheet" - 070109 CO 2009 Carlisle. —;,4111-1112— Carlisle SynTec EXPERIENCE THE CARLISLE DIFFERENCE f r• • Overview Carlisle's Sure -Weld 1P0 Non -Reinforced Hashing is a 60 -mil thermoplastic polyolefin (TPO)-based membrane available in 12" and 24" by 50' rolls. When the use of prefabricated accessories is not feasible, this product can be used to create inside and outside corners, field -fabricated pipe flashings, sealant pockets, and scuppers. Standard colors are white, tan, and gray. Features and Benefits New and improved TPO Flashing provides 35% more flexibility, making it easier to field -fabricate details Compounded with the same Octatuard XT'" weathering package as Carlisle's Sure -Weld TPO membranes for maximum longevity Superior weldability allows for consistent, high-quality seams in penetrations and other critical roof areas Available in white, gray, and tan colors to match Carlisle's Sure -Weld TPO membranes Installation 1. TPO Flashing is used to flash various roofing system details and penetrations. The specific installation method will vary based on the situation. 2. Use a lower temperature setting on the heat welder than when welding reinforced TPO membrane. Typically, a setting of "6" on a scale of "10" is appropriate for welding TPO Flashing. 10.06.15 © 2015 Carlisle. REPRINT CODE: 605089 - "Sure -Weld TPO Non -Reinforced Hashing Product Data Sheet" 3. Use the edge of the roller to crease the flashing into any membrane step -offs for a proper seal. Review Carlisle specifications and details for complete installation information. Precautions » Review the applicable Safety Data Sheet for complete safety information prior to use. Sunglasses that filter out ultraviolet light are strongly recommended, as tan and white surfaces are highly reflective. Roofing technicians should dress appropriately and wear sunscreen. Store TPO Flashing in a cool, shaded area and cover with light-colored, breathable, waterproof tarpaulins. TPO Flashing that has been exposed to the weather for approximately 7 days or longer must be prepared with Weathered Membrane Cleaner prior to hot air welding. Typical Properties and Characteristics Properties ASTM Test Specification Method Tolerance on nominal thickness, % 0 412 plus 15/ minus 10 Weight, Ib/ft2 (kg/m2), typical 0.30 (1.5) Tensile strength, min., psi (Mpg) D 412 Die C 1200 (8.3) Elongation, ultimate, min., % 0 412 Die C 600 Tear strength, min., lbf/in (kN/m) D 624 Die C 250 (43.8) Ozone resistance, 168h C 100 pphm, D 1149 No Cracks 50% ext. Heat aging: 28 days at 240"F (116°C) Tensile strength, min., psi (MPa) Elongation, ultimate, min., % Tear strength, min., Ibf/in (kN/m) Linear dimensional change, max. % Resistance to Xenon -arc weathering Xenon -Arc, 10,080 kJ/m2 total radiant Exposure, visual condition at 10X D 573 D 412 0412 0624 O 1204 G 155 0.70 W/m2 80°C B.P.T. 1000 (6.9) 500 200 (35.0) ±4 No Cracks Typical properties and characteristics are based on samples tested and are not guaranteed for all samples of this product. This data and information is intended as a guide and does not reflect the specification range for any particular property of this product. LEEb6 Information Pre -consumer Recycled Content Post-consurner Recycled Content Manufacturing Location Solar Reflectancelndex (SRI) 0% 0% Greenville, IL N/A 800-479-6832 I P.O. Box 7000 I Carlisle, PA 17013 I Fax: 717-245-7053 I uvtrw,cariisiesy oteo,cam Carlisle and Octa0uard 01 are trademarks of Carlisle. Sure -Weld is a registered trademark o1 Carlisle. LEED is a registered trademark of the U.S. Green Building Council. TECHNICAL DATA BULLETIN CARLISLE SYNTEC INCORPORATED CARLISLE SURE -WELD® NON -REINFORCED TPO FLASHING GENERAL: Carlisle Sure -Weld Flashing is a 60 -mil non -reinforced thermoplastic polyolefm (TPO) based membrane used for inside/outside corners, field fabricated pipe flashings, sealant pockets and scuppers, when the use of pre -molded accessories are not feasible. Sure -Weld Flashing is available in 12" and 24" by 50' rolls (30 cm and 60 cm by15 m rolls). Standard colors are white, tan and gray and Special Colors are available. TYPICAL PROPERTIES AND CHARACTERISTICS: Properties Tolerance on nominal thickness, % Weight, ib/ft2 (kg/m2), typical Tensile strength, min., psi (Mpa) Elongation, ultimate, min., % Tear strength, min., lbf/in (kN/m) Ozone resistance, 168h @ 100 pphm, 50% ext Heat aging: 28 days at 240°F (116°C) Tensile strength, min., psi (MPa) Elongation, ultimate, min., % Tear strength, min., lbf/in (kN/m) Linear dimensional change, max., % Resistance to Xenon -arc weathering Xenon -Arc, 10,080 kJ/m2 total radiant Exposure, visual condition at 10X ASTM Test Method D 412 D 412 Die C D 412 Die C D 624 Die C D 1149 D 573 D 412 D 412 D 624 D 1204 G 155 0.70 W/m2 80°C B.P.T. Specification +15 / -10 0.30 (1.5) 1200 (8.3) 600 250 (43.8) No Cracks 1000 (6.9) 500 200 (35.0) ±4 No Cracks CAUTIONS AND WARNINGS: 1. Review the applicable Material Safety Data sheet for complete safety information prior to use. 2. UV filtering sunglasses are strongly recommended when working on Sure -Weld Roofing Systems. 3. Store Sure -Weld Flashing in a cool, shaded area and cover with light-colored, breathable, waterproof tarpaulins. Sure -Weld Flashing that has been exposed to the weather for approximately 7 days or longer prior to use must be prepared with Weathered Membrane Cleaner prior to hot air welding. H-5 (Page 1 of 2) INSTALLATION: 1. Sure -Weld Flashing is used to flash various roofing system structures and penetrations. The specific method for applying the flashing for each situation is different. The appropriate Carlisle Specification and/or Detail must be consulted prior to application. 2. Use a lower temperature setting on the heat welder than when welding the reinforced membrane. (Typically a setting of "6" on a scale of "10" is appropriate for welding Sure - Weld Flashing). 3. Use the edge of the roller to crease the flashing into any membrane step-off for a proper seal. Carlisle and Sure -Weld are trademarks of Carlisle Corporation. ©2008 Carlisle Corporation 12/08 H-5 (Page 2 of 2) 1 Q.29@la D00 Yrfig (KOWA@ C OgnQffG1W Low4lOC Bandling Aclhethic -r- 1111111111M i Overview Carlisle's Low-VOC Bonding Adhesive is a high-strength, solvent -based contact adhesive that allows bonding of EPDM and TPO membranes to various porous and non -porous substrates. This product meets the <250 gpl VOC content requirements of the OTC Model Rule for Single -Ply Roofing Adhesives. Low-VOC Bonding Adhesive is compatible with HP -H and SecurShield'" polyisocyanurate insulation, structural and lightweight insulating concrete, APA non -fire treated plywood, oriented strand board, wood fiberboard, SECUROCK®, DensDeck° Prime, masonry and various metal finishes. Low-VOC Bonding Adhesive is easily applied with a 9" (228 mm) medium nap roller, creating a strong adhesive bond between the membrane and substrate. This product does not comply with the following California counties' VOC regulations: Alameda, Contra Costa, El Dorado, Los Angeles, Marin, Napa, Orange, Riverside, Sacramento, San Bernardino, San Diego, San Francisco, San Mateo, Santa Clara, Solano, Sonoma and Tehama. These areas require the use of Carlisle's LOW-VOC Bonding Adhesive 1168. Features and Benefits • Can be applied with a medium nap roller for easy application » Compatible with EPDM or TPO membranes and a variety of substrates • Extended open time Mixing Stir thoroughly once per day until all settled polymers are dispersed and the adhesive is a uniform yellow color. During mixing, scrape the sides and bottom of the pail until the adhesive is a uniform yellow color with no dark streaks. Keeping the adhesive warm, as well as using an air -operated mixing paddle, will aid in the mixing process. td1RL 151 E , SYNTEC SYSTEMS Coverage Rate The coverage rate for Low-VOC Bonding Adhesive is 60 square feet (5.6 m2) per gallon finished surface. A 5 -gallon pail should cover no more than 300 square feet (28 m2) of finished area. Coverage rates are average and may vary due to conditions on the jobsite. Porous wall surfaces like masonry block require 2 coats of bonding adhesive. Allow primer coat to flash off completely prior to applying the second coat at the required coverage rate of 60 square feet per gallon. Application 1. Allow membrane to relax for half an hour or longer. Allowing the membrane to relax will result in the roof's surface having a smoother appearance. This is especially true for sheets that have folds or creases. The surface on or against which adhesive is to be applied shall be clean, smooth, dry, free of fins, sharp edges, loose and foreign materials, oil and grease. Depressions greater than 1/4" (6 mm) should be feathered using epoxy, mortar or other approved patching material. All sharp projections shall be removed by sweeping, blowing or vacuum cleaning. 2. After the Low-VOC Bonding Adhesive has been thoroughly mixed, apply to the substrate and membrane using a 9" (228 mm) medium nap roller. Application shall be continuous and uniform, avoiding globs or puddles that could result in solvent blisters. Heavy "wet" areas can be re -rolled to break the skin, allowing the solvents to flash off. The solvents in Low-VOC Bonding Adhesive must be allowed to flash -off until the adhesive does not string or transfer to a dry finger touch, but remains tacky. This is called the "tack test". It's recommended to continually monitor the adhesive for flash -off after the application of the adhesive. Install the membrane after the adhesive passes the tack test to avoid trapped solvent blisters. In hot weather, flash -off time can occur in as little as 5 minutes or less. Temperature, sun, shade or humidity can affect flash -off time. Note: Any coated area that is exposed to rain should be allowed to dry and then recoated. Do not apply adhesive to splice areas or use in conjunction with Carlisle's Pressure -Sensitive products. 3. Roll the membrane onto the adhesive -coated substrate while avoiding wrinkles. Immediately brush down the bonded portion of the sheet with a stiff -bristle push broom to achieve maximum contact. For wall applications, use a neoprene type hand roller after brooming to ensure maximum contact. If blisters occur from trapped solvent, allow the solvent to naturally dissipate for 4 or 5 days and then re -roll or re -broom the membrane so it lays flat. Review Carlisle specifications and details for complete application information. 800-479-6832 I P.O. Box 7000 I Carlisle, PA 17013 I Fax: 717-245-7053 I www.carllslesyntec.com _ EXPERIENCE THE CARLISLE DIFFERENCE Low-VOC Bonding Adhesive Precautions » Review the applicable Material Safety Data Sheet for complete safety information prior to use. • Jobsite storage in excess of 90°F (32°C) may affect product shelf life. Prolonged exposure to below -freezing temperatures will cause the adhesive to thicken and eventually solidify in the can. Should the Low-VOC Bonding Adhesive be stored below freezing, restore to room temperature for a minimum of 24 hours prior to use; the adhesive will perform as intended once it is returned to a liquid state. When temperatures are expected to be consistently below 40°F, a heated enclosure or hot box is recommended for jobsite storage. Keep the adhesive warm (60-90°F) for ease of application. » Low-VOC Bonding Adhesive is EXTREMELY FLAMMABLE. It contains solvents that are dangerous fire and explosion hazards when exposed to heat, flame or sparks. Do not smoke while applying. Do not use in a confined or unventilated area. Vapors are heavier than air and may travel along ground or may be moved by ventilation and ignited by pilot lights, other flames, sparks, heaters, smoking, electrical motors, static discharge or other ignition sources at locations distant from material handling point and flashback. All containers should be grounded when material is transferred from one container to another. A red caution label is required when shipping. A fire extinguisher should be available. In case of fire, use water spray, foam, dry chemical or carbon dioxide. Do not use a solid stream of water, because it can scatter and spread the fire. » Avoid breathing vapors. Keep container closed when not in use. Use with adequate ventilation. If inhaled, remove to fresh air. If not breathing, perform artificial respiration. If breathing is difficult, give oxygen. Call a physician immediately. During application, efforts must be made to prevent fumes from entering the building via air ventilation ducts. Do not place open containers or mix adhesive near fresh air intake units. When possible, shut down or seal off the closest units. » If swallowed, DO NOT INDUCE VOMITING. Call a physician immediately. » Avoid contact with eyes. Safety glasses or goggles are recommended. If splashed in eyes, immediately flush eyes with plenty of clean water for at least 15 minutes. Contact a physician immediately. » Avoid contact with skin. Wash hands thoroughly after handling. In case of contact with skin, thoroughly wash affected area with soap and water. Contact physician if irritation persists. Note: To protect hands from irritating ingredients, Carlisle recommends that applicators wear permeation -resistant gloves (that meetANSI/ISEA 105-2005) when using this product. » Do not thin Low-VOC Bonding Adhesive. Thinning will affect performance. Excessively thick or gelled material should be discarded. GIRLIHLE e SYNTEC SYSTEMS These materials are sensitive to atmospheric moisture; heat will accelerate the effect of moisture. Opened containers of bonding adhesive should be used within 48 hours. Adhesive will begin to thicken after this point, making it difficult, and eventually impossible, to control adhesive thickness. » Adhesive must be allowed to flash -off but not become over dry. If membrane is mated with the substrate prior to the adhesive flashing off, blistering will occur. If membrane is mated with the substrate after the adhesive has over -dried, loose or unadhered areas will occur. Thin application of adhesive increases risk of over -drying. » KEEP OUT OF THE REACH OF CHILDREN. Typical Properties and Characteristics Base Synthetic rubber Color Yellow Solids 22% VOC 250 g/I max Flash Point 0°F (-17°C) closed cup Brookfield Viscosity 3500 centipoise Average Net Weight 8.0 lbs/gal (0.96 kg/I) Packaging 5 -gal pail Shelf Life 1 year Typical properties and characteristics are based on samples tested and are not guaranteed for all samples of this product. This data and Information is Intended as a guide and does not reflect the specification range for any particular property of this product. LEED® Information Pre -consumer Recycled Content 0% Post -consumer Recycled Content 0% Manufacturing Location Carlisle, PA VOC Content < 250 g/L L 04.06.15 0 2014 Carlisle. REPRINT CODE: 603629 - "Low-VOC Bonding Adhesive Product Data Sheer 800-479-6832 1 P.O. Box 7000 1 Carlisle, PA 17013 I Fax: 717-245-7053 1 www.carlislesyntec.com Carlisle and SecurShield are trademarks of Carlisle. SECUROCK is a registered trademark of USG. DensDeck Prime is a trademark of G -P Gypsum Corporation. LEED is a registered trademark of the U.S. Green Building Council. EXPERIENCE THE CARLISLE DIFFERENCE Low-VOC Primer Overview Let Carlisle simplify your next EPDM or TPO installation with Low-VOC Primer. Low-VOC Primer is a solvent -based product designed for one- step priming of EPDM or TPO surfaces prior to the application of FAT-, Coverstrip, SecurTAPE" and all other pressure -sensitive (PS) products. This product is designed to comply with VOC regulations. Features and Benefits One-step primer used in conjunction with all pressure -sensitive accessories on EPDM or TPO membranes Coverage rates up to 700 square feet per gallon (65 m2) with TPO or Kleen EPDM membrane » VOC less than 250 g/I Excellent long term peel and shear strength Coverage Rates Approximately 250 ft2/gallon (23 m2) can be expected when properly applied to dusted EPDM membrane. Coverage rates as high as 700 ft2/gallon (65 m2) can be expected with TPO or Kleen EPDM membrane. Mixing Mixing is not recommended, even when settling occurs. The polymer used in primer contains a non -soluble partitioning agent that may settle to the bottom of the can. Do not attempt to break up or stir back into the primer. G4RL/5LE BYNTEC SYSTEMS Application 1. Remove all foreign material. a. Excessive mica dust may be removed from EPDM by brooming or wiping with a clean, dry rag or a Carlisle HP Splice Wipe. b. The use of Weathered Membrane Cleaner may be necessary on TPO or EPDM. This process is essential on membrane that has been exposed for a number of weeks. Note: Permeation -resistant gloves (that meet ANSI/ISEA 105-2005) are required for hand protection when cleaners or primers are being used. 2. Application of Low-VOC Primer a. Standard EPDM Membrane - Apply the primer with a clean HP Splice Wipe (or equivalent). Scrub the splice area of the membrane in a circular motion to achieve a thin, even coating on the membrane. The properly cleaned/primed area will be uniform in color without streaks and free of globs or puddles. b. TPO or Kleen EPDM Membrane - Roller -apply the primer to the membrane with a short nap -length paint roller. The coated area will be free of globs or puddles. Note: The use of excessive amounts of Low-VOC Primer will not enhance the adhesion of the PS products to the membrane. Use only the amount necessary to obtain 100% coverage of the area where the tape or adhesive will be applied. 3. Allow the Low-VOC Primer to flash -off until it does not transfer to a dry finger touch yet remains tacky. Install the pressure -sensitive product immediately after the primer has flashed -off to promote adhesion and avoid contamination. 4. Complete the detail as specified in Carlisle's Specifications and Details. Review Carlisle specifications and details for complete installation information. 800-479-6832 I P.O. Box 7000 I Carlisle, PA 17013 I Fax: 717-245-7053 I www.carlislesyntec.com EXPERIENCE THE CARLISLE DIFFERENCE Low-VOC Primer Precautions » » Avoid allowing the primer to over dry or lose tack. Install pressure -sensitive flashings, corners and tapes immediately after primer flashes off and remains tacky. This product is FLAMMABLE. Precautions must be taken to keep the primer away from heat, flame and sparks during storage and use. Avoid contact with eyes and skin. Avoid breathing vapors. Keep container closed when not in use. Use with adequate ventilation. If inhaled, remove to fresh air. If not breathing, perform artificial respiration. If breathing is difficult, give oxygen. Call a physician immediately. During application, efforts must be made to prevent fumes from entering the building via air ventilation ducts. Do not place open containers or mix adhesive near fresh -air intake units. When possible, shut down or seal off the closest units. If swallowed, DO NOT INDUCE VOMITING. Call a physician immediately. Permeation -resistant gloves (that meet ANSI/ISEA 105-2005) must be worn with Low-VOC Primer to protect hands from staining and irritating ingredients. Partitioning agents suspended in Low-VOC Primer tend to settle and do not need to be remixed. Stirring is not required. Use Low-VOC Primer full strength. Do not thin. Thinning will affect performance. Low-VOC Primer is not white in color. Care should be taken to limit the amount of primer exposed beyond the splice area for improved aesthetics. Jobsite storage temperatures in excess of 90°F (32°C) may affect product shelf life. Should the primer be stored at temperatures lower than 60°F (15°C), restore to room temperature prior to use. Keep can tightly closed when not in use and protect from moisture contamination. Once exposed to moisture in the air, Low-VOC Primer begins to cure and may gel within a few days. A gasket of membrane or sealant can be used to create a positive seal. Due to solvent flash -off, condensation may form on freshly applied Low-VOC Primer when the ambient temperature is near the dew point. If condensation develops, the application of primer must be discontinued (proper adhesion will not be obtained). Allow the surface to dry and apply a thin freshener coat of primer to the previously coated surface when conditions allow. REVIEW THE LOW-VOC PRIMER MATERIAL SAFETY DATA SHEET FOR COMPLETE SAFETY INFORMATION PRIOR TO USE. KEEP OUT OF REACH OF CHILDREN. 07.17.15 © 2015 Carlisle. REPRINT CODE: 604721 - "Low-VOC Primer Product Data Sheet" G4RL15LE EYNTEC QY e F:fV'7 Typical Properties and Characteristics Base Synthetic Rubber Color ' Olive Drab Solids 9% Flash Point 40°F (4.4°C) Packaging (6) 1 gallon (3.8 liters) cans per carton Shelf Life 9 months Average Weight 9.55 lbs/gallon (1.14 kg/liter) Typical properties and characteristics are based on samples tested and are not guaranteed for all samples of this product. This data and information is intended as a guide and does not reflect the specification range for any particular property of this product. LEED® Information Pre -consumer Recycled Content i 0% Post -consumer Recycled Content 0% Manufacturing Location Carlisle, PA VOC Content <250 g/L 800-479-6832 I P.O. Box 7000 I Carlisle, PA 17013 I Fax: 717-245-7053 I www.carlislesyntec.com Carlisle, FAT, SecurTAPE and Sure -White are trademarks of Carlisle. LEED is a registered trademark of the U.S. Green Building Council. Product Data WHITE ONE -PART POURABLE SEALER 1 fi M Itis\YY • Overview Let Carlisle simplify your next white membrane installation with its One -Part Pourable Sealer. White One -Part Pourable Sealer is a single -component, moisture -curing, elastomeric polyether sealant that is compatible with all Carlisle roofing membranes. The material is designed to provide a flexible, durable and long-lasting seal around hard -to -flash penetrations in Carlisle Roofing Systems. White One - Part Pourable Sealer provides rapid skin time when exposed to atmospheric moisture, forming a waterproof rubber surface in less than one (1) hour. Moisture curing continues, until a two (2) -inch -deep solid rubber seal encases the penetration. Complete cure time will vary depending on relative humidity and temperature. The sealant's one -part, pourable consistency allows for quick pocket filling without mixing. Unused sealant remaining in the pouch will remain useable for up to 30 days if pouch is resealed with original cap. Intended Uses White One -Part Pourable Sealer is designed to provide a flexible, durable and long-lasting seal around hard -to -flash penetrations in all Carlisle Roofing Systems. Features and Benefits • Ready to use, no mixing required • Pouch can be resealed with original cap • Provides a flexible, durable and Tong -lasting seal around hard -to - flash penetrations • Provides a watertight seal in less than one hour Coverage Rate One 0.5 -gallon (2 -liter) pouch will fill 122 cubic inches of volume within a sealant pocket. For example, one (1) 6" Carlisle Pourable Sealer Pocket (56 cubic inches) will require 0.23 gallons (0.87 liters) of pourable sealer to fill completely (with no penetrations). Application* 1. Surfaces must be free of moisture, dirt and any contaminants. Any previously applied asphalt, caulking or sealants must be removed from the penetration(s). 2. FII any voids in the roof deck around the penetration(s) to prevent sealant from seeping through the roof. Pourable Sealer must be a minimum of 2" (50 mm) deep. All penetrations must be a minimum of 1" (25 mm) from the sides of the pocket. 3. For EPDM Installations Install Carlisle's Pressure -Sensitive Pourable Sealer Pocket in accordance with the 11-16A detail. Apply Carlisle's EPDM Primer to all surfaces, including the deck membrane, penetration and uncured flashing that will be in contact with the One -Part Pourable Sealer. Primer should not be applied to the blue plastic strip that forms the inside wall of the PS Pourable Sealer Pocket. Allow primer to dry. For TPO Installations Install Carlisle's TPO Molded Sealant Pockets in accordance with the IJ -16A detail. Apply Carlisle's TPO Primer to all surfaces, including the deck membrane, penetration and uncured flashing that will be in contact with the One -Part Pourable Sealer. Allow primer to dry. For PVC Installations Install Carlisle's PVC Molded Sealant Pockets in accordance with the U -16A detail. Clean all surfaces with PVC cleaner, including the deck membrane, penetration and all surfaces of the pocket that will be in contact with the One -Part Pourable Sealer. Allow the PVC cleaner to dry. Do not use primer. 4. Remove cap from 0.5 -gallon (2 -liter) pouch and pour One -Part Pourable Sealer directly into pocket. Fill pocket completely until rim is covered with One -Part Pourable Sealer, making sure all voids are filled. 800-479-6832 • P.O. Box 7000 • Carlisle, PA 17013 • Fax: 717-245-7053 • www.carlislesyntec.com DYNTEC £:YF8TLM3 Product Data WHITE OWE -PART POURABLE SEALER 5. To save unused sealant, squeeze air from pouch and replace cap. Unused sealant should be used within 30 days. REVIEW CURRENT CARLISLE SPECIFICATIONS AND DETAILS FOR SPECIFIC APPLICATION REQUIREMENTS. Precautions 1. Review the applicable Material Safety Data Sheet for complete safety information prior to use. 2. Avoid breathing vapors. Keep container closed when not in use. Use with adequate ventilation. If inhaled, remove to fresh air. If not breathing, perform artificial respiration. If breathing is difficult, give oxygen. Call a physician immediately. 3. If swallowed, DO NOT INDUCE VOMITING. Call a physician immediately. 4. Avoid contact with eyes. Safety glasses or goggles are recommended. If splashed in eyes, immediately flush eyes with plenty of clean water for at (east 15 minutes. Contact a physician immediately. 5. Avoid contact with skin. Wash hands thoroughly after handling. In case of contact with skin, thoroughly wash affected area with soap and water. 6. Do not thin. Thinning will affect performance. 7. Shelf life is based on storage in original, unopened or undamaged containers at temperatures ranging from 60°F to 80°F (15°C to 26°C). Should the White One -Part Pourable Sealer be exposed to lower temperatures, restore to room temperature prior to use. 8. Coverage rates are average and may vary due to conditions of the jobsite. 9. KEEP OUT OF THE REACH OF CHILDREN. White One -Part Pourable Sealer Typical Properties and Characteristics* Specific Gravity 1.37 (11.5 lbs/gallon) -1.44 (12 lbs/gallon) Viscosity (Brookfield RTV), cps Seh leveling 20,000 —50,000 Color White Odor Mild ester smell (mint) when wet. Odorless when dry. Elongation © Break, % ASTM 450 00412 (7 -day ambient cure) Hardness, (Shore A) 25-35 ASTM C0661 Tack -Free lime ASTM C0679 Less than 1 hour Low temperature flex PASS Minus 20°F (-29°C) Service temperature Minus 40°F to 200°F (-40°C to 93°C) ASTM 2453 Packaging 4 0.5 -gallon pouches per bucket 4 2 -liter pouches Weight per carton 26 lbs/bucket (11.8 kg) Shelf life (unopened container) 18 months * Typical properties and characteristics are based on samples tested and are not guaranteed for all samples of this product. This data and information is intended as a guide and does not reflect the specification or specification range for any particular property of this product. LEED° Info Pre -consumer Recycled Content 0% Post -consumer Recycled Content 0% VOC Content <25 g/L Manufacturing Location Schoolcraft, MI 800-479-6832 • P.O. Box 7000 • Carlisle, PA 17013 • Fax: 717-245-7053 • www.carlislesyntec.com Carlisle is a trademark of Carlisle. LEED Is a registered trademark of the U.S. Green Building Council. REPRINT CODE: 605212—'White One -Part Pourable Sealer Product Data Sheet° — 070212 m 2012 Carlisle. BYNTEC £i YSTEM8 SW Low-VOC Primer --_� LOW VOC TPO PRIMER Overview Carlisle's TPO Low-VOC Primer is a low -solids, clear (translucent color) solvent -based splice primer used to prepare TPO membrane for improved adhesion to pressure -sensitive TPO accessories. This Low-VOC product is ideal for use in states where VOC content is a concern. Features and Benefits » One-step primer allows for excellent adhesion of pressure -sensitive TPO accessories to TPO membrane » Less than 250 g/L VOC content Coverage Rate 200 — 250 ft2 (19 — 24 m2) (one surface) per gallon. Application 1. Thoroughly stir this product until all settled pigment is blended into the solution. Solids suspended in TPO Low-VOC Primer tend to settle; stir or agitate the solution frequently during use. 2. The surface to which the primer is being applied should be dry and clean. If the TPO membrane is exposed to weather, the areas that are to be primed must be cleaned with Weathered Membrane Cleaner prior to the primer application. I1 CYN7-.EC Y i ET 1 3. Apply TPO Low-VOC Primer using a paintbrush or medium -nap paint roller. The membrane surface should be uniform in color with no streaking or puddling. Apply primer to a wider area than the actual splice area to ensure complete coverage. 4. Allow primer to flash off completely before applying pressure - sensitive TPO accessories. Drying conditions will vary depending on ambient air conditions. Review Carlisle specifications and details for complete application information. Precautions WARNING! HARMFUL IF SWALLOWED. FLAMMABLE LIQUID. MAY BE IRRITATING TO SKIN AND EYES. Wash thoroughly after handling. Avoid contact with eyes, skin and clothing. Use of solvent -resistant gloves and safety glasses recommended. Keep away from heat, sparks, motors and open flame. DO NOT SMOKE WHILE USING. Keep lid closed when not in use. If swallowed, DO NOT INDUCE VOMITING. Call physician immediately. In case of eye contact, flush with water for at least 15 minutes. In case of skin contact, wash with soap and water. If irritation develops, call physician. In case of fire, handle as a solvent or gasoline fire. Use dry chemical, carbon dioxide or foam fire extinguishers. Water fog or spray may be used to smother the fire and cool containers. Do not use a solid stream of water to fight fire because it can scatter and spread the fire. Use Low-VOC TPO Primer full strength. Do not thin. Thinning will affect performance. Jobsite storage temperatures in excess of 90°F (32°C) may affect product shelf life. Should the primer be stored at temperatures lower than 60°F (15°C), restore to room temperature prior to use. REVIEW THE MATERIAL SAFETY DATA SHEET FOR COMPLETE SAFETY INFORMATION PRIOR TO USE. 800-479-6832 I P.O. Box 7000 I Carlisle, PA 17013 I Fax: 717-245-7053 I www.carlislesyntec.com EXPERIENCE THE CARLISLE DIFFERENCE Sure -Weld . Low-VOC Primer Typical Properties and Characteristics Color J Translucent Appearance Solids Content 10-12% Smooth, no lumps Weight Per Gallon ; 10.4 lbs (4.72 Kg) Packaging Shelf Life 6 1 -gallon cans per carton 1 year in unopened container Typical properties and characteristics are based an samples tested and are not guaranteed for all samples of this product. This data and information is intended as a guide and does not reflect the specification range for any particular property of this product. G4RL/SLE SYNTF_CfYFiFM LEED® Information Pre -consumer Recycled Content 0% Post -consumer Recycled Content ] 0% VOC Content < 250 g/L Manufacturing Location I Michigan Center, MI 800-479-6832 I P.O. Box 7000 I Carlisle, PA 17013 I Fax: 717-245-7053 I www.carlislesyntec.com Carlisle Is a trademark of Carlisle. LEED is a registered trademark of the U.S. Building Council. 11.20.13 ® 2013 Carlisle. REPRINT CODE: 605926 — "Sure -Weld TPO Low-VOC TPO Primer Product Data Sheet° Product Data TPO AND PVC Low-VOC ADHESIVES AND SEALANTS Increased govemmental regulations, combined with the low-VOC requirements of LEED® and other environmentally conscious programs, have caused a shift in the construction community towards the use of low-VOC products. The roofing industry is certainly not excluded from these changes. To qualify for low-VOC status, an adhesive must have a VOC content of 250 grams/liter or less, and a sealant must have a VOC content of 450 grams/liter or less. However, certain products are excluded from the VOC content requirement based on packaging size, vapor pressure or other reasons. Carlisle is leading the way in meeting the growing number of VOC regulations. Carlisle is continually developing products that meet the low-VOC requirements of new govemmental regulations and green building codes. The following products meet the current limitations of known regulations as of the publish date. Low-VOC Bonding Adhesive is a high-strength solvent -based contact adhesive that allows bonding of Carlisle TPO membranes to various porous and non -porous substrates. It is specially formulated using a blend of VOC-exempt and non-exempt solvents that are ideal for use where low-VOC products are required. Low-VOC Bonding Adhesive 1168 is available for use in Califomia. *Proper mixing is required Low-VOC Bonding Adhesive Typical Properties and Characteristics* VOC Content 250 grams/liter max Packaging 5 -gallon pail Shelf Life 1 year Aqua Base 120 is a unique, semi -pressure -sensitive, water-based bonding adhesive for certain FleeceBACK®, TPO and PVC membranes offering superior peel strengths without VOCs or strong odors. Aqua Base is installed using a one- sided wet lay -in application for FleeceBACK membranes. Aqua Base 120 can also be utilized as a contact adhesive for TPO and PVC membranes. Coverage rate is 100 sq. ft. (9 sq. meters) per gallon and it is packaged in 5 -gallon pails. Aqua Base 120 Typical Properties and Characteristics* VOC Content 8 grams/liter Packaging 5 -gallon pall Shelf Life 1 year Low-VOC Bonding Adhesive 1168 is a high-strength solvent -based contact adhesive that allows bonding of Carlisle TPO membranes to various porous and non -porous substrates. Low-VOC Bonding Adhesive 1168 is compliant for use in all CA counties. Low-VOC Bonding Adhesive 1168 Typical Properties and Characteristics* VOC Content 250 grams/liter max Packaging 5 -gallon pall Shelf Life 1 year Low-VOC PVC Bonding Adhesive Carlisle's Low-VOC PVC Bonding Adhesive is a high-strength solvent -based contact adhesive that allows bonding of PVC and KEE- enhanced PVC membranes to various porous and non -porous substrates. This product is also approved for use in CA. Low-VOC PVC Bonding Adhesive Typical Properties and Characteristics* VOC Content 250 grams/liter max Packaging 5 -gallon pail Shelf Life 1 year 800-479-6832 • P.O. Box 7000 • Carlisle, PA 17013 • Fax: 717-245-7053 • www.carlislesyntec.com CYNTE-C SYCT£'ME3 1P0 AND PVC Low-VOC ADHESIVES AND SEALANTS Low-VOC TPO Primer is a low -solids, clear, solvent -based primer used to prepare TPO membrane for adhesion to pressure - sensitive TPO coverstrip and BUSS where VOC regulations or restrictions exist. ,_7.7/ LOW V TPO PRI rsr Low-VOC TPO Primer Typical Properties and Characteristics* VOC Content 250 grams/liter max Packaging (6)1 -gallon can Shelf Life 1 year in unopened can SATTm TPO Membrane a heat -weldable single -ply thermoplastic polyolefin (TPO) sheet designed for fully adhered applications. The 100% solids, hot - melt pressure -sensitive adhesive eliminates VOC and odor concerns typically associated with fully adhered systems. SAT_TPO Membrane ., Typical Properties and Characteristics* VOC Content none Packaging 10' x 100', 50' Shelf Life 1 year Weathered Membrane Cleaner is used to clean both new and in-service membrane. ft helps to loosen and remove dirt and other contaminants from the surface of the membrane and leaves a suitable surface for primer application or welding. *Note: This product is not compliant in CA. Weathered Membrane Cleaner - TPO Typical Properties and Characteristics* VOC Content Exempt based on vapor pressure* Packaging 5 -gallon closed -top pall or (2) 1-galion closed -top palls Shelf Life N/A Weathered Membrane Cleaner =PVC Typical Properties and Characteristics* VOC Content VOC Exempt Packaging 5 -gallon can Shelf Life N/A Clear Cut Edge Sealant a medium solids, free-flowing, polymeric material designed to be used for sealing cut edges of Carlisle's TPO or PVC membranes. Qualifies for small quantity exemption in most areas. CUT EDGE SEALANT Clear,,Cut, Edge Sealant- TPO Typical Properties and Characteristics* VOC Content Packaging Exempt for small quantity (8) 16 -oz. bottles/ctn Shelf Life 1 year C el'` ar' Ctit dge Sealant' Typical Properties and Characteristics* VOC Content Exempt for small quantity Packaging (12) 16 -oz. bottles/ctn Shelf Life 1 year 800-479-6832 • P.O. Box 7000 • Carlisle, PA 17013 • Fax: 717-245-7053 • www.carlislesyntec.com CYNTEC E'YCTE:INC • TPO AND PVC Low-VOC DHESWES .-ND SEALANTS Universal Single -Ply Sealant is a 100% -solids, solvent -free, one - part, polyether sealant that provides a weathertight seal to a variety of building substrates and can be used as a termination bar sealant for Carlisle's EPDM, TPO and PVC roofing systems. Universal Single -Ply Sealant Typical Properties and Characteristics* VOC Content 0 grams/liter Packaging 24 cartridges, 10.1 fl. oz. each Shea Life 1 year In unopened container Water Cut -Off Mastic is a one -component, low -viscosity, self -wetting butyl blend mastic used with roofing and waterproofing systems, and when a membrane is being terminated using a compression -type seal. Water'rCut=off Mastic :: Typical Properties and Characteristics* VOC Content 250 grams/liter max Packaging 25 tubes/carton Shelf Life 1 year in unopened container White One -Part Pourable Sealer is single -component, moisture - curing, elastomeric polyether sealant that is compatible with all Carlisle roofing systems and provides a watertight seal around hard -to -flash penetrations. Thermoplastic One -Part Pourable Sealer Typical Properties and Characteristics* VOC Content 0 grams/liter Packaging (4) pouches per bucket Shelf Life 18 months CAV-GRIPTM is a Low-VOC, methylene chloride - free, multi-purpose contact adhesive/ primer recommended for enhancing the bond of Carlisle's 725TR. CAV -GRIP is also used as a primer for unweathered asphalt. CAV -GRIP Typical Properties and Characteristics* VOC Content 71 grams/liter Packaging Shelf Life 40 -Ib aerosol cylinder 1 year in unopened container 800-479-6832 • P.O. Box 7000 • Carlisle, PA 17013 • Fax: 717-245-7053 • www.carlislesyntec.com CYNTCC EYETEMD • Product Data TPO AND PVC Low-VOC ADHESIVES AND SEALANTS FAST"' Adhesive is a low-rise, two -component, insulating polyurethane adhesive. It can be used to adhere a variety of insulations and Carlisle's FleeceBACK membranes, and is applied in full spray or beads. FAST Adhesive Typical Properties and Characteristics* VOC Content 0 grams/liter Packaging 15- and 50 -gallon drums, Bag -in -a -Box and Dual Cartridges (Part A and B) Shelf Life 1 year (Part A and 8) Cold Applied Adhesive is an asphalt -modified polyether, one-sided, wet lay -in adhesive designed to adhere to AFX membrane and Carlisle's modified base sheet. wirtir-mu Cold Applied Adhesive Typical Properties and Characteristics* VOC Content 32 grams/liter Packaging 5 -gallon pail Shelf Life 9 months * Typical properties and characteristics are based on samples tested and are not guaranteed for all samples of this product. This data and information is intended as a guide and does not reflect the specification range for any particular property of this product. Flexible FAST Adhesive is a low-rise, two -component, insulating and energy -absorbing polyurethane adhesive with 150% elongation to better handle building movement and roof system expansion and contraction. Flexible FAST Adhesive Typical Properties and Characteristics* VOC Content 0 grams/liter Packaging 15- and 50 -gallon drums (Part A and 8) Shelf Lite 1 year (Part A and B) CCW-702LV Primer is a quick -drying, solvent -based, high -tack adhesive/primer specifically designed to promote maximum adhesion of Carlisle's 725TR Air and Vapor Barrier. CCW 702LV Primer Typical Properties and Characteristics* VOC Content 250 grams/liter max Packaging 5 -gallon pall Shelf Life 1 year in unopened container 800-479-6832 • P.O. Box 7000 • Carlisle, PA 17013 • Fax: 717-245-7053 • www.carlislesyntec.com Carlisle, SAT, Sure -Weld, Sure -Seal, Sure-Whhe, Sure -Tough, FleeceBACK, FAT, FAST, SecurTAPE, CAV -GRP and Inseam Sealant are trademarks of Carlisle. LEED is a registered trademark of the U.S. Green Building Council. REPRINT CODE: 600262 — TPO and PVC Low-VOC Adhesives and Sealants Product Data Sheet — 08.23.12 ® 2012 Carlsle. £;YNTCC EYCTGMC EXPERIENCE THE CARLISLE DIFFERENCE Weathered Membrane Cleaner WEATHERED MEMBRANE CLEANER Overview Let Carlisle simplify your next EPDM or TPO installation with Weathered Membrane Cleaner. Weathered Membrane Cleaner is used to clean both new and in-service Sure -Seal®, Sure -White® and Sure -Tough® EPDM membranes and Sure -Weld® TPO membrane prior to the seaming process. It helps to loosen and remove dirt and other contaminants from the surface of the EPDM and TPO membranes and leaves a suitable surface for welding or the subsequent application of primer. Weathered Membrane Cleaner should be used when preparing EPDM membranes for application of primer, adhesives, SecurTAPE'", Factory -Applied Tape" (FAT) and flashing. Do not use Weathered Membrane Cleaner on PVC membranes—instead use PVC Membrane Cleaner. Features and Benefits Easily removes dirt and other contaminants from EPDM and TPO membranes Prepares EPDM membrane for application of primer, adhesives and tape Prepares aged or contaminated TPO membrane for welding Coverage Rate Coverage rate depends on the age of the membrane and the amount of dirt/debris on the surface. Assume 400 ft2 (37 m2) (one surface) per gallon. Application EPDM 1. Remove as much loose material as possible from the membrane surface where the adhesive or pressure -sensitive product will be applied by brooming or wiping the area with a dry rag. Extreme conditions of accumulated dirt may require a low sudsing detergent and water cleaning (rinse area thoroughly with CLEAN water and allow to dry). 2. Saturate a clean HP Splice Wipe (or equivalent) with Weathered Membrane Cleaner. SCRUB the area in a circular motion. Continue to clean the area, changing wipes frequently, until the surface is a consistent color with no streaking. Additional cleaning is required at factory seams (scrub parallel to the seam). Allow to dry. 3. Apply primer according to product instructions and/or roofing system specification. TPO Weathered Membrane Cleaner may be used to remove construction dirt or to prepare aged TPO membrane prior to welding. New TPO: 1. Saturate a clean HP Splice Wipe (or equivalent) with Weathered Membrane Cleaner. 2. Wipe the area to be cleaned until the membrane is a consistent color with no streaking and allow to dry. 3. Weld the cleaned material together with an appropriate hot-air welder. Welding Aged Material: 1. Using a Primer Pad and Weathered Membrane Cleaner, scrub the area to be welded. (The cleaner will become white with membrane residue during this step of the procedure.) 2. Clean all residue from the area to be welded with an HP Splice Wipe (or equivalent). Allow to dry. 3. Weld the cleaned material together with an appropriate hot-air welder. Review Carlisle specifications and details for complete application information. 800-479-6832 I P.O. Box 7000 I Carlisle, PA 17013 I Fax: 717-245-7053 I www.carlislesyntec.com EXPERIENCE THE CARLISLE DIFFERENCE Weathered Membrane Cleaner Precautions Review the applicable Material Safety Data Sheet for complete safety information prior to use. Weathered Membrane Cleaner is EXTREMELY FLAMMABLE. This product contains materials that are fire and explosion hazards when exposed to heat, flame or sparks. Store and use away from all sources of heat, flame or sparks. Do not smoke while applying. Do not use in a confined or unventilated area. Vapors are heavier than air and may travel along ground to a distant ignition source and flash back. A red caution label is required when shipping. During application, efforts must be made to prevent fumes from entering the building via air ventilation ducts. Do not place open containers or mix adhesive near fresh -air intake units. When possible, shut down or seal off the closest units. Avoid breathing vapors. Keep container closed when not in use. Use with adequate ventilation. If inhaled, remove to fresh air. If not breathing, perform artificial respiration. If breathing is difficult, give oxygen. Call a physician immediately. If swallowed, DO NOT INDUCE VOMITING. Call a physician immediately. Avoid contact with eyes. Safety glasses or goggles are recommended. If splashed in eyes, immediately flush eyes with plenty of water for at least 15 minutes. Contact a physician immediately. Avoid contact with skin. Wash hands thoroughly after handling. In case of contact with skin, thoroughly wash affected area with soap and water. Note: Permeation -resistant gloves (that meet ANSI/ISEA 105-2005) are recommended to be worn when using this product to protect hands from irritating ingredients. KEEP OUT OF THE REACH OF CHILDREN. Typical Properties and Characteristics Color Solids Flash Point Boiling Point Packaging Clear 0% 65°F (18°C) 260°F (127°C) 5 -gallon (18.9 -liter) closed -top pail 2 x 1 -gallon (3.8 -liter) closed -top pail Typical properties and characteristics are based on samples tested and are not guaranteed for all samples of this product. This data and information is intended as a guide and does not reflect the specification range for any particular property of this product. LEED® Information Pre -consumer Recycled Content { 0% Post -consumer Recycled Content L 0% Manufacturing Location Carlisle, PA VOC Content* 755 grams/liter *This product is exempt from VOC regulations. 800-479-6832 I P.O. Box 7000 I Carlisle, PA 17013 I Fax: 717-245-7053 I www.carlislesyntec.com 09.23.13 © 2013 Carlisle. Carlisle, Sure -Seal, Sure -Tough, Sure -White, Sure -Weld, SecurTape and Factory -Applied Tape (FAT) are trademarks of Carlisle. REPRINT CODE: 603626 - "Weathered Membrane Cleaner Product Data Sheet" LEED is a registered trademark of the U.S. Green Building Council. .5Q 120 sq. IL per gallon and It l fps b$g�e e.x+ .e atggs� 4u lioo�tae (vs a zt a 2 -11 I1411- I gg111 111 ax"cll.AasmAs.00 �=Gigli a d i_ QtglilisAIFIB ee 13 Sg.� 3aam8.8a 8.. s � r, OIiCS 17 V 2 P 6 t E 8 a SW MIEN CARLISLE'S ADHESIVES & SEALANTS Low-VOC TPO Primer r is a low solids, dear (translucent color) solvent -based splice primer used to prepare TPO membrane for improsed adhesion to pressure sensitive TPO products. IRLYARP Color es Translucent Appearance Smooth, no lumps Solids 10.12% Avenge Net Wal4M V0C Content Packaging 10,4 lbs/gallon (4.72 ka/gailon) 250 grams/Iger maximum 6-1 gallon cans/carton Shell life 1 year, unopened container Investing /n Roofing Sofudcns for Over 45 Years Cut -Edge Sealant LS a free flowing polymeric material designed for sealing cut edges (exposed fabric) of Sure -Weld gnr reinforced membrane. CUT mat MIS 'mALANT 1 ALANr. a ■ ) Base Svnthellc Rubber Color Clear. White Average Solids Rash Point Clear - 14% White - 25% Clear - 39• F (4° C) White - 81• F (27• C) Average Brookfield Viscosity V0C Clear -3500 Centipoise White - 2000 Centipoise Clear -750 GramsAger White - 700 Gramsditer Average Net Weight Packaging Shell Llfe Clear- 7.4 Ibsigai (3.3 Kg). White - 7.8 lbs/pal (3,5 Kg) 8 - 16oz Bottles/carton (3.811 1 year Sure -Seal' Water Cut -Off Mastic h a one -component, low viscosity, self -welting butyl bl end mastic pled with roofing and waterproofing systems. It is primarily used when membrane is being terminated using a compression -type seal. phcal Properties and Characteristics Color Gray Solids 80% Rash Point 40° F (4• Cl posed Cup Service Temp. -40• F to_200• F (-40• C to 93" C) Specific Gravity 1.29 Cold Weather Rex Excellent Anv _kaon Brookfe d Viscosity 1 324000 cps Packaging 10 tubes/Carton. 5 gallon pals V0C 250 gramsAlter Clean up Weathered Membrane Cleaner Average Net Weight/gallon 10.7 lbs, (4,9 Kyyalonl Shelf Lite 1 year. unopened container 90D+SYNTEC • P.O. Box 7000 • Carlisle, PA 17013 • Fax 717-245-7053 • www.cediste-syetec.com a 0' System Accessories Universal Single -Ply Sealant is 100%sollds,sovent-free, one -part polyether sealant that provides a weather tight seal to a variety of building substrates. Largiaakmailluramia.411011111111111111111111111 Color Whits Viscosity 850,000 Cps, Tack Free Time 35 minutes depending on temp/humlditv Cure Time 3-7 days depending an temp/humidity Row, Sag or Slump None (1/4" Bead) Staining None Ozone Resistance Good UV Resistance Excelent Cured Hardness (Shore A) 17-23 Shear Strength 150 PSI Weight per Carton 261bs Packaging 24 Cartridges,10.1 R. Oz. each She Life 12 months, unopened container ® 90"F Thermoplastic One Part Sealant is a single component, moisture autng, elauomeric polyether paint that is compatible with Carlisle's Thermoplastic membranes. The material h designed to provide a flexible, durable and long lasting seal around hard -to -flash penetrations In Thermoplastic Roofing Systems. The product on also be used for attaching lightning rod bases and ground cable dips to the membrane surface. Thermoplastic One Part Pourable Sealer provides rapid sldn time when exposed to atmospheric moisture forming a waterproof rubber surface In less than one (1) hour. Molsmre curing continues, until a two (2) — inch deep solid rubber seal encases the penetration. Complete are time w10 vary depending on relative hunddity and temperature. The sealant's one -part, pourable consistency allows for quick pocket filling without mhing. Carlisle's TPO Primer must be applied to all surfaces, Including membrane, flashings and penetrations that will be M contact with the Thermoplastic One Part Pourable Sealant. Unused sealant remalning in a pouch will renin useable up to 30 days If pouch is resealed with original cap. T fcal Properties and Characteristics SpecOk Gravity 1.4 (11.6 lbs/gealon) - 1.44(12.0 lbs/on) Viscosity (Brookfield RTVi. cps Color Odor Self leveling 20,000 - 50,000 White Mild ester smell (mint) when wet Odorless when dry bonpatlon ® Break, %ASTM 0-0412 - (7 day ambient cure) 450 Hardness (Shote A) ASTM C-0661 25.35 Tack Ree Time ASTM C-0679 - rip 70 degrees F. Less than 1 hour Low temperature flex PASS 20• F. Shrinkage (14 day cum) No measurable shrinkage Santa temperature ASTM 2453 -40• F m 200• F, Long term weatherabifdy ASTM G53 No crazing or crackdng - 98 cycles lb 12 horns/cycle - (condensate exposure - 4 hrs ® 50°C) - (U.V. exposure - 8 hrs ® 70"C) Packagkw Weight Per Carton Shelf Life (unopened container) 4-0.5 gallon pouches per bucket 2916s. / bucket 12 months Carlisle SynTec .' ., EXPERIENCE THE CARLISLE DIFFERENCE Sure-Welit Fully Adhered Roofing Systems Sure -Weld Membrane for Fully Adhered Systems is available in the following: Color j White, Gray, and Tan Thicknesses (mils) 4 60 and 80 Standard Widths i 6' 8', 10', and 12' Standard Lengths 100' Existing or New Deck Type Insulation Required Recommended Insulations Insulation Attached By Membrane Attached By CG4RL/SLE SYNTEC SYSTEMS Typical Applications O Sure -Weld TPO Reinforced Membrane O Carlisle Insulation Fasteners and Plates O TPO Bonding Adhesive O Acceptable Insulation © Approved Roof Deck System Features & Benefits: » Heat -weldable membranes High wind uplift performance High hail and puncture resistance Top -ply membrane thickness adds improved long-term weatherability and durability Sure -Weld TPO white and tan membranes are ENERGY STAR®` qualified New Construction Steel Plywood Lt. Wt. Structural Wood or OSB Concrete Concrete Planks Gypsum & Fibrous Cement Yes No *Refer to No Yes Yes Specs Carlisle Polyiso, Carlisle HP Recovery Board, or Carlisle Polystyrene with an approved cover board FAST" Adhesive (non -penetrating), lnsulfast, or Carlisle HP Fasteners TPO Bonding Adhesive FOR TEAR -OFF OPTIONS REFER TO NEW CONSTRUCTION ABOVE. For current code approvals and warranties, visit Carlisle's web site or contact a design analyst. * Refer to Carlisle's Sure -Weld Design Criteria Portion of the Current Specification. 1, Re -roofing Smooth - Surface BUR Gravel - Surfaced BUR Existing Single -Ply No Yes Yes Refer to New Construction -4- Refer to New Construction Ai-- Refer to New Construction 800-479-6832 I P.O. Box 7000 I Carlisle, PA 17013 I Fax: 717-245-7053 I www.carlislesyntec.com 1, EXPERIENCE THE CARLISLE DIFFERENCE Sure -Weld' 'MO Fully Adhered Roofing Systems Sure -Weld TPO Membrane Carlisle's Sure -Weld TPO is a premium, heat -weldable, single -ply thermoplastic polyolefin membrane, engineered to provide outstanding long-term performance in new roof construction and re -roofing applications. All Sure -Weld TPO membranes utilize the patented OctaGuard XT'" weathering package technology, which is able to withstand extreme durability testing intended to stimulate exposure to several climates. Sure -Weld TPO Accessories Carlisle also offers over a dozen prefabricated, in -stock, standard -order accessories, and countless custom -order accessories. All carry a CFA (Certified Fabricated Accessory) stamp of approval, so you know they are manufactured to the highest standards. Every Carlisle CFA -approved accessory saves time and money during installation. Certified Fabricated /Accessory Installation Carlisle's Sure -Weld TPO Fully Adhered Roofing System utilizes white, gray, or tan membranes in standard reinforced 45- or 60 -mil thicknesses or 80 -mil -thick reinforced Sure -Weld EXTRA membranes. Insulation, where required, is secured to an acceptable roof deck. Sure - Weld TPO membrane sheets are fully adhered to the insulation or substrate with Carlisle's Sure -Weld TPO Bonding Adhesive. Adjoining sheets are hot-air welded. The above information represents a typical Carlisle Sure -Weld TPO Fully Adhered Roofing System. Refer to Carlisle's published specifications and details for more complete information. Membrane and System Strengths Sure -Weld TPO membrane is available in white, gray, and tan, in 6', 8',10', and 12' widths Provides superior puncture and hail resistance White and tan Sure -Weld TPO reflectivity values exceed industry standards; they both are ENERGY STAR* qualified Puncture warranty available with 60- and 80 -mil Sure -Weld EXTRA membrane Membranes are eco -friendly as they do not contain chlorine or plasticizers 11.02.15 © 2015 Carlisle. REPRINT CODE: 600337 - "Sure -Weld TPO Fully Adhered System Sheet" C4RL15LE SYNTEC SYSTEMS System Codes » UL Class A, B, and Universal Slope ratings are available over any deck type » FM uplift values of up to 150 psf can be achieved For code specifics, refer to Carlisle's Sure -Weld Code Approval Guide. Quality Assurance Carlisle Authorized Roofing Contractors have received training to install Carlisle's Sure -Weld TPO Roofing Systems. Inspection Upon installation completion, and prior to the issuance of a membrane system warranty, an inspection will be conducted by a Carlisle Field Service Representative. Warranty Consult your roofing contractor or Carlisle Manufacturer's Representative/Distributor for associated warranty charges. This system, properly installed and inspected on a commercial project, may receive: » » » » A 10 -year Total System or 15 -year Golden Seal Warranty when all materials used for the roofing installation are manufactured or marketed by Carlisle A 10 -year Reflectivity Warranty (based on ENERGY STAR criteria) with white membrane A 20 -year Golden Seal Warranty with 60 -mil Sure -Weld EXTRA membranes A 25- or 30 -year Golden Seal Warranty with 80 -mil Sure -Weld EXTRA membrane Higher wind speed warranties (up to 120 mph peak gust wind speed) available upon review by Carlisle For more specifics or for International warranty programs, contact Carlisle. APPROVED ENERGY STAR `ENERGY STAR recommends that using the Roof Savings Calculator (rsc.ornl.gov), which factors in both heating and cooling costs, to determine whether a cool roof will be an energy efficient choice for your geographic climate and building type. 800-479-6832 I P.O. Box 7000 I Carlisle, PA 17013 I Fax: 717-245-7053 I www.carlislesyntec.com Carlisle, Sure -Weld, OctaGuard XT and FAST are trademarks of Carlisle. ENERGY STAR is a registered trademark owned by the U.S. Government. *ENERGY STAR qualification is only valid in the U.S. h1/4 THERMOPLASTIC MEMBRANES NOTE: RhinoBond METHOD OF MEMBRANE ATTACHMENT IS NOT FOR USE WITH NON—FACED EPS (EXPANDED POLYSTYRENE) OR XPS (EXTRUDED .N POLYSTYRENE) INSULATIONS. W .I � 8'-O" s t • 12" 24" 24" 24" 12" I I I ® PERIMETER ZONE 8 FASTENERS PER 4'X8' BOARD 8'-0" I4'-0" 4'-0" nd- N s 18" I 30" 30" 18" 1 ® FIELD OF ROOF 6 FASTENERS PER 4'X8' BOARD PERIMETER AREA 1 FIELD AREA w a RhinoBond RAISED ROOF EDGE OR PARAPET WALL • • • • • ROOF FIELD AREA CARLISLE FASTENER & • RhinoBond FASTENER PLATE .• • • • • SEE B FOR • DIMENSIONS %oe 4'-0" 1 4'-0" • • . • SEE A FOR DIMENSIONS 4'-0" 1 4'-0" ROOF FIELD AREA 8'-0" MIN. PERIMETER ZONE MEMBRANE FASTENED MINIMUM 12" O.C. AT ANGLE(S)-1 CHANGES. FOR ADDITIONAL INFORMATION SEE DETAIL RB -2 DETAIL RB -2 • DECK TYPE DECK THICKNESS FASTENER THERMOPLASTIC COATED PLATE STEEL 22 GAUGE (0.8mm) CARLISLE HP—X FASTENER 3-1/8" (79.4mm) DIAMETER PLYWOOD 15/32" (12mm) NOTE: AT IN—FILL MINOR PIECES, USE MIN. 2 FASTENERS. INCHES TO MILLIMETERS inch 2" 3.5" 4" 12" 18" 24" 30" mm 51 89 102 305 457 610 762 FEET TO MIWMETERS FEET 1' 4' 8' mm 305 1219 2438 --THERMOPLASTIC MEMBRANE RhinoBond ATTACHMENT METHOD - NUMBER OF FASTENERS AND LOCATIONSRB-1 DETAIL Na --- --' .. , 44-,44 ,+ — APPROVED SUBSTRATE 0 —' SEE NOTE(S) For additional information, refer to S ecifications p RhinoBond 2016 Carlisle SynTee a division of Carlisle Construction Materials Incorporated THERMOPLASTIC MEMBRANES 8' 4' 4' 12" 4' 24" 1 6 FAST ENERS '-6" 1 2'-6" 2'-6" 1 1'-6" FIELD 8' 4' 4' 12" 4' 24" a 6i 1 „ 10 FASTENERS PERIMETER 8' • 4' 4' 4' 12" 15 FASTENERS C•V CN e " 1'-6" 1'-6" 1'-6" 1'-6" 12" CORNERS 1 RhinoBond GRADE "C" STEEL DECKS GRADE "E" STEEL DECKS 8' 12" 4' 24" 12" 8 FASTENERS 12" 24" 24" 24" 1 12" APPROVED INSULATION BOARD FIELD PERIMETER 8' 4' 4' 12" 4'12" 12" n • It 'i NJ K 20 FASTENERS CORNERS • --THERMOPLASTIC MEMBRANE RhInoBond ATTACHMENT METHOD FM FASTENING PATTERNS DETAIL NO. j i RB -3 -- APPROVED SUBSTRATE 0 -SEE NOTE(S) For additional Information, refer to Specifications RhinoBond 02018 Carlisle SynTec a division of Carlisle Construction Materials Incorporated Fields Roof Service Since 1957 ruipu Thank you for allowing me to estimate your roofing project. We at Fields Roof Service enjoy helping our customers throughout the process of choosing the best roof system to meet your needs. If you have any questions regarding your estimate, please contact me at (253) 797-8048. We look forward to working with you. • Why Choose Fields Roof Service For Your Project? • Factory Trained and Certified installers — We have taken the time to send our foreman to Carlisle for their Foreman's Workshop and factory training. We are committed to providing a superior installation on your roof. • Continuing education — We keep up with new products, code requirements and installation techniques to give you a system to meet your needs for the years to come. • Years of experience — We started in 1957 and our ownership group has direct relationship with the original sales force who bought FRS from Larry Fields. We are a family driven business who is here to stay and will serve you for the next 58 years! • Choosing the right components for your roofing system • Composition roof systems with the best products to meet your budget. • Single ply roof systems featuring PVC and TPO with system NDL warranties up to 20 years. • Polyglass-Modified Bitumen roofing to meet the demands of our old school customers. • Inland Coatings -Specialized rubber roof coatings to meet your coating needs. • Metal Roofing -From AEP, Sound Building supply and The Bryer Company. • Customer and Industry References • Kirk Tarbet-Convoy Supply LTD -General Manager USA 425-582-1518 • Steve Silcock-Carlisle Syntec USA -NW Representative 425-220-1190 REVIEWED FOR CODE COMPLIANCE APPROVED SEP 2 2 2016 City of Tukwila BUILDING DIVISION • 3 Stripe Property Management -Oliver Kurabi 425-269-4464 7900 East Greenlake Drive North Seattle, WA • Goodman Real Estate -Tyson Ferreria 206-391-4401 2801 Alaskan Way #301 Seattle, WA • Rainier Property Management -Chad Champion 206-372-9680 1618 S. Lane St. Seattle, WA p� • Ahiv Label and Associates -Tom ;�}nc_T ... ito..,..t. 7nG_247 Q100 21G w",._ --_-I Ave c Seattle, WARECEIVED CITY OF TUKWILA • CBRE Management -Fritz Vaupel 206-292-1600 1420 5''' Avenue #1700 Seattle, WA SEP 15 2016 PERMIT CENTER Field's Roof Service Featured Products • Carlisle Coating & Waterproofing Inc. - for product information visit wxxw.calisle-ccw.com or call (800) 527-7092 for flat roofs • Certainteed Corporation • For product information visit www.certainteed.com or call (800) 782-8777 for composition shingles • For certified contractor information search Locate a Professional on the web site (please note we have obtained Select Shingle Applicator, Master Shingle Applicator, Quality Master and Professional Roofer Advisory Council) • For viewing Certainteed products on a home similar to yours search Design Center on the web site • For product information on venting search the Ventilation on the web site • GAF Corporation -Shingles and Single Ply roofing products. w ww.gaf.com • AEP Span Metal Roofing -for product information visit www.aepspan.com or call 253-383-4955 for metal roofing. • Inland Coatings- for product information visit w \ inlandcoatings.com or call 800-456-8467 • Custom-bilt Metals - for product information visit w ww.custombiltmetals.com or call (800)826-7813 for metal product • Sound Building Supply -for product information visit u1N-w.soundbuildingsun,_n v.coyn or call 425-264-0264. • Polyglass-for Modified Bitumen and roof coatings visit wr‘tiw.polyglass.com • CrystaLite Inc - for product information visit www.crystaliteinc.com or call (800) 666-6065 for skylights Sincerely, Steve Bozorth Cell -253-797-8048 CARLISLE GOLDEN SEAL OTAL ROOFING SYSTEM WARRANTY with limited coverage for accidental punctures SERIAL NO. DATE OF ISSUE: BUILDING OWNER: NAME OF BUILDING: SAN/lPI.E BUILDING ADDRESS: DATE OF COMPLETION OF THE CARLISLE TOTAL ROOFING SYSTEM: DATE OF ACCEPTANCE BY CARLISLE: Carlisle Roofing Systems, Inc., (Carlisle) warrants to the Building Owner (OWNER) of the above described building, that; subject to the terms, conditions, and limitations stated in this warranty, Carlisle will repair any leak in the Carlisle Golden Sear Total Roofing System (CARLISLE TOTAL ROOFING SYSTEM) installed by a Carlisle Authorized Roofing applicator for a period of years commencing with the date of Carlisle's acceptance of the Carlisle Total Roofing System installation. However, in no event shall Carlisle's obligations extend beyond years subsequent to the date of substantial completion of the Carlisle Total Roofing System. See below for exact date of warranty expiration. The Carlisle Total Roofing System is defined as the following Carlisle brand materials: Membrane, Flashings, Counterflashings, Adhesives and Sealants, Insulation, Cover Boards, Fasteners, Fastener Plates, Fastening Bars, Metal Work, insulation adhesives and any other Carlisle brand products utilized in this installation. —373 TERMS, CONDITIONS, LIMITATIONS 1. Owner shall provide Carlisle with written notice via letter, fax, or email within thirty (30) days of the discovery of any leak in the Carlisle Total Roofing System. Owner should send written notice of a leak to Carlisle's Warranty Services Department at the address set forth at the bottom of this warranty. By so notifying Carlisle, the Owner authorizes Carlisle or its designee to investigate the cause of the leak. Should the Investigation reveal the cause of the leak to be outside the scope of this Warranty, investigation and repair costs for this service shall be paid by the Owner. 2. if, upon inspection, Carlisle determines that the leak is caused by a defect In the Carlisle Total Roofing System's materials, or workmanship of the Carlisle Authorized Roofing Applicator in installing the same, Owner's remedies and Carlisle's liability shall be limited to Carlisle's repair of the leak. 3. This warranty shall not be applicable if, upon Carlisle's inspection, Carlisle determines that any of the following has occurred: (a) The Carlisle Total Roofing System is damaged by natural disasters, Including, but not limited to, lightning, fire, Insect infestations, earthquake, tomado, hail, hurricanes, and winds of (3 second) peak gust speeds of mph or higher measured et 10 meters above ground; or (b) Loss of integrity of the building envelope and, or structure including, but not limited to partial or complete loss of roof decking, wall siding, windows, doors or other envelope components or from roof damage by wind-blown objects; or: (c) The Carlisle Total Roofing System Is damaged by any Intentional or negligent acts, acddents, misuse, abuse, vandalism, civil disobedience, or the like; however, this warranty does provide limited coverage to provide for the repair of anyleaks In the Carlisle Total Roofing System caused by accidental punctures (but not Including punctures caused by snow removal or other trades during new construction). The extent of this limited warranty to repair punctures shall not exceed 16 man hours per year during the lige of the warranty. (d) Deterioration or failure of building components, Including, but not limited to, the roof substrate, walls, mortar, HVAC units, non -Carlisle brand metal work, etc., occurs and causes a leak, or otherwise damages the Carlisle Total Roofing System; or (e) Acids, oils, harmful chemicals and the like come in contact with the Cadlsle Total Roofing System end cause a leak, or otherwise damage the Carlisle Total Roofing System. (f) The Carlisle Total Roofing System encounters leaks or Is otherwise damaged by condensation resulting from any condition within the building that may generate moisture. 4. This Warranty shall be null and void if any of the following shall occur. (a) If, after installation of the Carlisle Total Roofing System by a Carlisle Authorized Roofing Applicator there are any alterations or repairs made on or through the roof or objects such as, but not limited to, structures, fixtures, solar panels, wind turbines, roof gardens or utilities are placed upon or attached to the roof without first obtaining written authorization from Carlisle; or (b) Failure by the Owner to use reasonable care In maintaining the roof, said maintenance to include, but not be limited to, those items listed on Carlisle's Care 8 Maintenance Information sheet which accompanies this Warranty. 5. Only Carlisle brand insulation products are covered by this warranty. Carlisle specifically disclaims liability, under any theory of law, for damages sustained by or caused by non -Carlisle brand insulation products. 6. During the term of this Warranty, Carlisle shall have free access to the roof during regular business hours. 7. Carlisle shall have no obligation under this Warranty while any bills for installation, supplies, seMce, and warranty charges have not been paid In full to the Carlisle Authorized Roofing Applicator, Carlisle, or material suppliers. 8. Carlisle's failure at any time to enforce any of the terms or conditions stated herein shall not be construed to be a waiver of such provision. 9. Carlisle shall not be responsible for the cleanliness or discoloration of the Carlisle Total Roofing System caused by environmental conditions including, but not limited to, din, pollutants, or biological agents. 10. Carlisle shall have no liability under any theory of law for any claims, repairs, restoration, or other damages including, but not limited to, consequential or incidental damages relating, directly or Indirectly, to the presence of any irritants, contaminants, vapors, fumes, molds, fungi, bacteria, spores, mycotoxins, or the like In the building or In the air, land, or water serving the building. 11. This warranty is not assignable by operation of law or otherwise. Application may be made by a new building owner for reissuance of the warranty during the original warranty period. Certain procedures including, but not limited to, an inspection of the Roofing System by a Carlisle representative and fees will apply to any reissuance. Carlisle reserves the right, in its sole discretion, to refuse to reissue this warranty. CARUSLE DOES NOT WARRANT PRODUCTS UTILIZED IN THIS INSTALLATION WHICH IT HAS NOT FURNISHED; AND SPECIFICALLY DISCLAIMS LIABILITY, UNDER ANY THEORY OF LAW, ARISING OUT OF THE INSTALLATION AND PERFORMANCE OF, OR DAMAGES SUSTAINED BY OR CAUSED BY, PRODUCTS NOT FURNISHED BY CARLISLE OR THE PRIOR EXISTING ROO Q.MAT RIALrOVER'VN I( i THE CARUSLE TOTAL ROOFING SYSTEM HAS BEEN INSTALLED. REVIEWED FOR I THE REMEDIES STATED HEREIN ARE THE SOLE AND EXCLUSIVE fpR'F LE TOTAL ROOFING SYSTEM OR ITS COMPONENTS. THERE ARE NO WARRANTIES EITHER EXPRESSEURED iNgbl G1 .IMPLIED ARRANTIES OF FITNESS FOR A PARTICULAR PURPOSE AND MERCHANTABILITY, WHICH EXTEND BEYOND T , Of CARUSLE HALL NOT BE LIABLE FOR ANY INCIDENTAL, CONSEQUENTIAL OR OTHER DAMAGES INCLUDING, BUT NOT LIMITED TO, -LOSS OF PROFIT OR DAMAGE TO THE BUILDING OR ITS CONTENTS UNDER ANY THEORY OF LAW. BY: Robert H. McNeill AUTHORIZED SIGNATURE TITLE: Director, Technical and Warranty Services P.O. Box 7000 Carlisle, PA 17013 Phone. 800.23 Fax '17/4 5 7121 WA -F0010 (6/13) SEP 2 2 2016 City of Tukwila BUILDING DIVISION caw 11 41.1 RECEIVED CITY OF TUKWILA SEP 15 2016 PERMIT CENTER G4RL15LE a Safety Data Sheet Material Name: White One -Part Pourable Sealer Section 1- PRODUCT AND COMPANY IDENTIFICATION Product #: 307603 Material Name: White One Part Pourable Sealer Chemical Family: Mixture Product Use: Moisture cure sealant for pourable sealant pockets. Restrictions on Use: For industrial use only. Manufacturer Information Carlisle SynTec 1285 Ritner Highway Carlisle, PA 17013 USA Phone: +1-800-479-6832 Emergency Phone #: +1-800-424-9300 (CHEMTREC) 'ILC Section 2 - HAZARDS IDENTIFICATION Classification in accordance with paragraph (d) of 29 CFR 1910.1200. Hazardous classification: Irritant Category 2 GHS Label Elements Symbol(s) Signal Word: Warning Hazard Statement(s) H315 Causes skin irritation H317 May cause allergic skin reaction H318 Causes serious eye damage Precautionary Statement(s) P273 Avoid release into the environment P280 Wear protective gloves/protective clothing/eye protection P302+P352 IF ON SKIN: Wash with plenty of soap and water. P305 + P351 IF IN EYES: Rinse cautiously with water for several minutes. P338 Remove contact lenses, if present and easy to do. Continue rinsing. P501 Dispose of contents/container in accordance with local regulation. REVIEWED FOR CODE COMPLIANCE APPROVED SEP 2 2 2016 City of Tukwila la BUILDING DIVISION RECEIVED CITY OF TUKWILA SEP 15 2016 PERMIT CENTER Page 1 of 7 Issue te: 2015-03-17 Revision 1.0 &%' .454 Print date: 2015-12-15 G4RLIHLE` CONSTF IL/CTYON !v?ATEF?IALS Safety Data Sheet Material Name: White One -Part Pourable Sealer Product #: 307603 R -Phrases R38 Irritating to skin. R41 Risk serious damage to eyes. R43 May cause sensitization by skin contact. S -Phrases S26 In case of contact with eyes, rinse immediately with plenty of water and seek medical advice. S39 Wear eye/face protection. Carcinogenity: This product contains no ingredient listed as a carcinogen on California Proposition 65 list. Section 3 - COMPOSITION / INFORMATION ON INGREDIENTS CAS Component Name Percent 1760-24-3 Amino Silane Section 4 - FIRST AID MEASURES Inhalation An unlikely route of entry. Remove to fresh air. Consult a physician. Skin Clean product from affected area with Ethyl alcohol, then wash with soap and water. Eyes Flush with large amounts of water for at least 15 minutes. Consult a Physician if ill effects or irritation occurs. Ingestion An unlikely route of entry. Consult a physician. Section 5 - FIRE FIGHTING MEASURES Extinguishing Media Water, CO2, Dry Chemical, Foam. Unusual Fire and Explosion Hazards: None Flashpoint: N/A. Upper Falmmability Limit: N/A Lower Flammability Limit: N/A Page 2 of 7 Issue date: 2015-03-17 Revision 1.0 Print date: 2015-12-15 CON877=?UC77O1v MATE'F7L L8 Safety Data Sheet Material Name: White One -Part Pourable Sealer Auto Ignition Temperature: N/A Sensitivity to Impact: N/A Sensitivity to Static Discharge: N/A Hazardous Combustion Products: Thermal decomposition may produce toxic fumes of Carbon Monoxide, Carbon dioxide, Sulfur oxides and Hydrogen sulfide. Product #: 307603 Section 6 - ACCIDENTAL RELEASE MEASURES Handling Precautions: Wear personal protective clothing and equipment, see Section 8. Avoid eye, skin and clothing contact. Cleanup: Collect spill with absorbent material such as cardboard, allow to cure and place into a container approved for waste disposal. Regulatory Requirements: Follow applicable OSHA regulations (29 CFR 1910.120). Section 7 - HANDLING AND STORAGE Handling Precautions: Use personal protection recommended in section 8. Avoid eye, skin and clothing contact. Prevention of Fires and Explosions: Product is not considered flammable under normal conditions, and product is not considered explosive. Storage Requirments: Store in a cool dry area (this product polymerizes when in contact with moisture.) Section 8 - EXPOSURE CONTROLS / PERSONAL PROTECTION Eye/face protection: Wear safety glasses or goggles to avoid eye contact. Skin Protection: Wear appropriate work clothing. Wear protective shoes. Recommended material: protective skin cream. Environmental Exposure Control: No specific controls are needed. Hand Protection: Wear impervious gloves such as vinyl to minimize contact with skin. Page 3 of 7 Issue date: 2015-03-17 Revision 1.0 Print date: 2015-12-15 CARLIHLE' Safety Data Sheet Material Name: White One -Part Pourable Sealer Product #: 307603 Section 9 - PHYSICAL AND CHEMICAL PROPERTIES r Appearance Odor Threshold Melting Point F - Paste, mild mint scent N/A N/A Freezing point N/A I Autoignition N/A Lower Explosive Limit Upper Explosive i Limit I Vapor Density (air=1) Density 11.591bs./gal. (calculated) Other Information No additional information available. N/A N/A >1 Physical State Water Solubility: Insoluble pH N/A Flash Point N/A Flash Point Method Based on FP of the most volatile component Vapor Pressure Specific Gravity (water=1) % Volatile VOC <1 1.39 1.07% 14.9 g/1 Section 10 - STABILITY AND REACTIVITY Chemical Stability Stable under normal conditions of use. Conditions to Avoid None Known Incompatible Materials None Known Hazardous decomposition products Thermal decomposition may produce toxic fumes of Carbon Monoxide (CO) and/or Carbon Dioxide (CO2) Page 4 of 7 Issue date: 2015-03-17 Revision 1.0 Print date: 2015-12-15 G4RLIHLE Safety Data Sheet Material Name: White One -Part Pourable Sealer Product #: 307603 Section 11- TOXICOLOGICAL INFORMATION Amino Silane (Refer to sections 2 and 3) Oral: LD50 > 2,000 mg/kg. Remark: Very low order of toxicity. Skin Absorption: LD50 > 2,000 mg/kg. Remark: Very low order of toxicity. Inhalation: LC50 Not acutely Toxic. Skin Direct Contact: Slight irritation Eye Direct Contact: Severe irritation. Remark: Causes corneal injury. Exposure Limits: Not applicable Sensitization: No Reproductive Toxicity: No Mutagenicity: No Teratogenicity: No Synergistic Products: None Section 12 - ECOLOGICAL INFORMATION No known applicable information. Section 13 - DISPOSAL CONSIDERATIONS If this product as supplied becomes a waste, it does not meet the criteria of a hazardous waste as defined under the Resource Conservation and Recovery Act (RCRA) 40 CFR 261. This product becomes a firm synthetic rubber when cured. Please allow to cure before disposal. Section 14 - TRANSPORT INFORMATION Special shipping information: None DOT: Not regulated TDG: Not available PIN: Not available Page 5 of 7 Issue date: 2015-03-17 Revision 1.0 Print date: 2015-12-15 G4RLI$LE r e�na. -s uQrac JrJ r✓�;; F�raAL Safety Data Sheet Material Name: White One -Part Pourable Sealer Product #: 307603 Section 15 - REGULATORY INFORMATION Rotterdam Convention (PIC) Annex III: listed (Tributyl tin compounds (impurities) <2ppm) U.S. Regulatory information OSHA 29 CFR 1910-1200 — Irritant. TSCA — All components of this product are listed on TSCA Inventory. CERCLA Reportable Quantity — Not applicable. SARA Title III: Section 302 Extremely Hazardous Substances — None. Section 304 — Not applicable. Section 311/312 — Immediate (acute) health hazard. Section 313 — None. RCRA — Refer to section 13. California Proposition 65 Carcinogens: This product does not contain any chemicals known by the State of California to cause cancer. California Proposition 65 Reproductive Toxins: This product does not contain any chemicals known by the State of California to cause reproductive harm. Canadian WHMIS Classification- D2B Section 16 - OTHER INFORMATION HMIG Rating Health: 1 Fire: 0 Reactivity: 0 Hazard Scale: 0 = Minimal 1= Slight 2 = Moderate 3 = Serious 4 = Severe * = Chronic hazard Summary of Changes New SDS: April 14, 2015 Key / Legend ACGIH - American Conference of Governmental Industrial Hygienists; ADR - European Road Transport; AU - Australia; BOD - Biochemical Oxygen Demand; C - Celsius; CA - Canada; CAS - Chemical Abstracts Service; CERCLA - Comprehensive Environmental Response, Compensation, and Liability Act; CLP - Classification, Labelling, and Packaging; CN - China; CPR - Controlled Products Regulations; DFG - Deutsche Forschungsgemeinschaft; DOT - Department of Transportation; DSD - Dangerous Substance Directive; DSL - Domestic Substances List; EEC - European Economic Page 6 of 7 Issue date: 2015-03-17 Revision 1.0 Print date: 2015-12-15 G4RLI$LE Safety Data Sheet Material Name: White One -Part Pourable Sealer Product #: 307603 Community; EINECS - European Inventory of Existing Commercial Chemical Substances; EPA - Environmental Protection Agency; EU - European Union; F - Fahrenheit; IARC - International Agency for Research on Cancer; IATA - International Air Transport Association; ICAO - International Civil Aviation Organization; IDL - Ingredient Disclosure List; IDLH - Immediately Dangerous to Life and Health; IMDG - International Maritime Dangerous Goods; JP - Japan; Kow - Octanol/water partition coefficient; KR - Korea; LEL - Lower Explosive Limit; LLV - Level Limit Value; LOLI - List Of LIstsTM - ChemADVISOR's Regulatory Database; MAK - Maximum Concentration Value in the Workplace; MEL - Maximum Exposure Limits; NFPA - National Fire Protection Agency; NIOSH - National Institute for Occupational Safety and Health; NJTSR - New Jersey Trade Secret Registry; NTP - National Toxicology Program; NZ - New Zealand; OSHA - Occupational Safety and Health Administration; PH - Philippines; RCRA - Resource Conservation and Recovery Act; REACH- Registration, Evaluation, Authorisation, and restriction of Chemicals; RID - European Rail Transport; SARA - Superfund Amendments and Reauthorization Act; STEL - Short-term Exposure Limit; TDG - Transportation of Dangerous Goods; TSCA - Toxic Substances Control Act; TWA - Time Weighted Average; UEL - Upper Explosive Limit; US - United States. Other Information Disclaimer: The information contained herein is based upon data and information available to us, and reflects our best professional judgment. This product may be formulated in part with components purchased from other companies. No warranty of merchantability, fitness for any use, or any other warranty is expressed or implied regarding the accuracy of such data or information. The results to be obtained from the use thereof, or that any such use does not infringe any patent, since the information contained herein may be applied under conditions of use beyond our control and with which we may be unfamiliar, we do not assume responsibility for the results of such application. This information is furnished upon the condition that the person receiving it shall make his own determination of the suitability of the material for his particular use. Page 7 of 7 Issue date: 2015-03-17 Revision 1.0 Print date: 2015-12-15 r3YNTET.: EY8TFi✓iv RhinoBond TPO REVIEWED FOR CODE COMPLIANCE • r,C• APPROVED } SEP 22 2016 City of Tukwila BUILDING DIVISION b (r). Oozvii RECEIVED CITY OF TUKWILA SEP 15 2016 PERMIT CENTER SYNYEC SYSTEN ?S Table of Contents 1. Sure -Weld TPO Code Approval Guide 4 2. Sure -Weld TPO Reinforced Membrane Product Data Sheet (PDS/TDB) 52 3. Sure -Weld TPO Reinforced Membrane Product Data Sheet (PDS/TDB) 56 4. Sure -Weld TPO Reinforced Membrane Product Data Sheet (PDS/TDB) 60 5. Sure -Weld TPO Accessories Sheet 64 6. Sure -Weld TPO Molded Sealant Pockets Product Data Sheet (PDS/TDB) 65 7. Sure -Weld TPO Low-VOC Primer Product Data Sheet (PDS/TDB) 67 8. Sure -Weld TPO Low-VOC Primer Product Data Sheet (PDS/TDB) 69 9. Sure -Weld TPO Inside Corners Product Data Sheet (PDS/TDB) 71 10. Sure -Weld TPO Inside Comers Product Data Sheet (PDS/TDB) 72 11. Sure -Weld TPO Flashing Product Data Sheet (PDS/TDB) 73 12. Sure -Weld TPO Outside Comers Product Data Sheet (PDS/TDB) 75 13. Sure -Weld TPO Outside Comers Product Data Sheet (PDS/TDB) 76 14. Sure -Weld TPO Walkway Roll Product Data Sheet (PDS/TDB) 77 15. Sure -Weld TPO Split Pipe -Seals Product Data Sheet (PDS/TDB) 78 16. Sure -Weld TPO Non -Reinforced Flashing Product Data Sheet (PDS/TDB) 80 17. TPO/PVC Low-VOC Adhesives & Sealants Product Data Sheet (PDS/TDB) 81 18. Weathered Membrane Cleaner Product Data Sheet (PDS/TDB) 85 19. Weathered Membrane Cleaner Product Data Sheet (PDS/TDB) 87 20. Sure -Weld Adhesives & Sealants Product Data Sheet (PDS/TDB) 89 21. RhinoBond Plates and Fasteners Product Data Sheet (PDS/TDB) 91 22. Sure -Weld Fully -Adhered System Sheet 92 23. Low-VOC Bonding Adhesive Product Data Sheet (PDS/TDB) 94 24. Low-VOC Bonding Adhesive Product Data Sheet (PDS/TDB) 96 25. Low-VOC Bonding Adhesive Product Data Sheet (PDS/TDB) 98 26. Low-VOC Primer Product Data Sheet (PDS/TDB) 100 27. Low-VOC Primer Product Data Sheet (PDS/TDB) 102 28. Low-VOC Primer Product Data Sheet (PDS/TDB) 104 29. White One -Part Pourable Sealer Product Data Sheet (PDS/TDB) 106 30. White One -Part Pourable Sealer Product Data Sheet (PDS/TDB) 108 31. RB -1 RhinoBond Attachment Method - Number of Fasteners and Location 110 32. RB -3 RhinoBond Attachment Method - FM Fastening Pattems 111 n. White One -Part Pourable Sealer SDS 112 mil 11 CARLISLE'S SURE -WELD Code Approval Guide August, 2016 Table of Contents Introduction Guidelines Sure -Weld Mechanically Fastened or Induction Welding Roofing Systems: UL Approvals: Non -Combustible - ANSI UL - Class A 4 Combustible - ANSI UL - Class A 5 Combustible - ANSI UL - Class B 7 Combustible and Non -Combustible - ANSI UL - Class C 8 FM Approvals: FM Approval - Field Sheet Securement Criteria 9 FM Approval - Induction Welding Securement Criteria 10 90 psf Uplift Resistance Test. 11 FM Class A Roof Deck 12 ANSI-SPRI 13 Sure -Weld Metal Retrofit Roofing Systems: Metal Retrofit. 14 Sure -Weld Adhered Roofing Systems: UL Approvals: Non -Combustible - ANSI UL - Class A 15 Combustible - ANSI UL - Class A 16 Combustible - ANSI UL - Class B 18 Combustible and Non -Combustible - ANSI UL - Class C 19 FM Approvals: SecurShield HD New Construction 20 SecurShield HD Recover 23 SecurShield HD Plus New Construction 24 SecurShield HD Plus Recover 27 Polyiso HP -H New Construction 28 Polyiso HP -H Recover 30 SecurShield New Construction 31 SecurShield Recover 33 Securock New Construction 34 Securock Recover 37 Dens Deck Prime New Construction 38 Dens Deck Prime Recover 40 OSB New Construction 41 OSB Recover 42 HP Recovery Board New Construction 43 HP Recovery Board Recover 45 Lightweight. 46 National, State & City Building Code Approvals 47 Dade County (South Florida) Approvals 47 Reference Notes 48 600163 I 8/2016 CARLISLE SynTec A Division of Carlisle Construction Materials, Incorporated CODE APPROVAL GUIDE August, 2016 INTRODUCTION This Code Approval Guide addresses both general information pertaining to Underwriters Laboratories (UL) and FM Approvals (FM) test criteria as well as specific UL and FM code approvals achieved with Carlisle's Sure -Weld Adhered and Mechanically -Fastened Roofing Systems. Various independent test laboratory results along with national building code approvals are also identified in this guide. Code approvals available with Carlisle's FleeceBackTm, Hot Mopped, Sure Flex and Sure -Seal® Roofing Systems are identified in separately published Code Approval Guides. Code ratings are categorized by roof system type (Mechanically -Fastened Adhered) and are separated into two sections: UL Approvals and FM Approvals. UL rated roof assemblies are grouped according to deck type (non-combustible or combustible) and are further categorized according to deck type and the specific type of construction (new, recover, tear -off or retrofit). The listed assemblies contained in the guide are grouped generically based on deck classification. Specific substrate requirements for each Carlisle roofmg system can be identified in the respective Carlisle specifications. In the UL and FM Approvals throughout this guide, when multiple layers of insulation are referenced, the product listed first identifies the insulation directly below the membrane. For example; a listing of HP Recovery Board/Polyisocyanurate indicates the HP Recovery Board is installed directly under the membrane. A listing of Gypsum Board/Polystyrene indicates the Gypsum Board is installed directly under the membrane. RL15LE' 600163 - SW Codes « TABLE OF CONTENTS i� 8/2016 GENERAL GUIDELINES FOR UL AND FM APPROVALS CODE COMPLIANCE No table of figures entries found. Approvals (FM) approved assembly is specified. Generally, the Carlisle published specifications reflect the minimum requirements necessary to obtain the applicable Carlisle warranty. Code requirements are not specifically covered in the Carlisle specifications and are considered to be above and beyond the provisions of the Carlisle warranty. Individuals specifying an approved assembly or selecting various products to achieve a specific UL/FM rating must recognize the importance of ensuring proper component selection to fully comply with the most current listings published. All materials used in the roofing systems must be UL and/or FM approved and must have been tested together as part of a complete roof assembly. In addition to the code approval listings in this guide, information pertaining to approved assemblies can also be obtained directly from UL and FM as follows: 1. Underwriters Laboritories On -Line Certification Directory (uLcom) 2. FM Approvals RoofNav website (roofnay.com). FM RoofNav assembly numbers can be obtained from this website. UL, FM Approvals and ASNUSPRI WD -1 Clarifications/Enhancements Underwriters Laboratories 1. The criteria required to obtain UL External fire ratings (Class A, B or C) can be identified in this guide or can be searched for on the UL website using the UL Category Code TGFU. UL ratings approved for use on combustible decks are also acceptable on non-combustible decks. 2. For UL internal fire ratings (hourly constructions — P Numbers), search the UL website use the UL Category Code BXUV. FM Approvals Uplift ratings listed in this guide are for the field of the roof. Additional requirements/enhancements are required by FM in the perimeter and corner areas, for deck securement and for perimeter nailer/edge attachment. Refer to FM Property Loss Prevention Data Sheets 1-28, 1-29 and 1- 49 for specific requirements. On FM insured projects, the FM insuring agent MUST review and approve the proposed roofing assembly prior to installation. When FM is not the insuring entity for the building, use the Approved American National Standard ANSUSPRI WD -1 for design purposes. Note: All Carlisle roof systems referenced within this document meet Class 1 construction and Severe Hail (SH) rating. Approved American National Standard ANSUSPRI WD -1 The ANSI/SPRI Wind Design Standard Practice for Roofing Assemblies should be referenced when a project is not FM insured. This document was developed as a consensus National Standard and provides a methodology for designing for wind uplift resistance of roofing system assemblies. Insulation fastening patterns are included in this document. The fastening patters are approved for use by Carlisle. SUMMARY Due to complexity of the code documents and the variety of inforniation that must be reviewed, it is important to consult with Carlisle and other respective manufactures concerning the most current available approvals. • Prior to project bid — Products specified by the architect must be thoroughly investigated to determine if the specified rating can be achieved and local building codes must be consulted regarding any additional requirements. • Prior to installation — Project managers should review the code requirements with field construction personnel to ensure compliance with project requirements. Upon completion of the roofing installation, each project is inspected by a Carlisle Technical Representative to ensure compliance with Carlisle's current specification requirements for the issuance of the applicable warranty. However, this inspection is not for the purpose of verifying code compliance. « TABLE OF CONTENTS 600163 - SW Codes iii 8/2016 Membrane Type: Sure -Weld ° (TPO) Mechanically -Fastened or Induction Welding Roofing Systems UL Approval - Non -Combustible - ANSI/UL 790 Spread of Flame Test (Class A) .045" or .060" Sure -Weld Standard Reinforced Membrane (White, Gray or Tan) .045" or .060" Sure -Weld HS Reinforced Membrane (White, Gray or Tan) .080" Sure -Weld EXTRA Reinforced Membrane (White, Gray or Tan) .060" or .080" Spectro-Weld Reinforced Membrane (White) Non -Combustible: Steel; St. Concrete; Gypsum; Tectum (Min. 2" thick) 1 , . , • Non -Combustible 4 :',,,r" - . HP -H, SecurShield, SecurShield HD, SecurShield HD Plus or SecurShield HD Composite- any combination, any thickness 4gr 4 "",'.,, . „ N/A ' -' -, .° 4 ,,e i o'•':','''.,'" ,4„..z.•1. -.k. - 1/2" 1-1/2" 2 Any UL Classified EPS or XPS Insulation, any thickness Minimum 1/2" SecurShield HD, SecurShield HD Plus or SecurShield HD Composite 1/2" 1/2" 3 Minimum 1" layer of HP -H, SecurShield, or SecurShield HD Composite over any UL Classified EPS or XPS Insulation, maximum 1.25 pef, any thickness N/A 1/2" 1/2" 4 Insulfoam SP or Insulfoam SP over Insulfoam EPS, any thickness and density. N/A 1" 1" 5 Insulfoam HD Composite or Insulfoam HD Composite over Insulfoam EPS, any thickness and density. N/A 1/2" 1/2" 6 Any UL Classified Insulation, any thickness (OPTIONAL) Minimum 1/4" SECUROCK® Gypsum - Fiber or Glass Mat Roof Boards Unlimited w/Glass Mat 3" w/Gypsum- Fiber 7 Any UL Classified Insulation, any thickness (OPTIONAL) Minimum 1/4" Dens Deck/Dens Deck Prime Roof Boards 3" -Sure -Weld 2 -1/2" -Sure -Weld EXTRA Unlimited 8 Any UL Classified Insulation, any thickness (OPTIONAL) Minirnum1/2" HP Recovery Board 1-1/2" 1-1/2" 9 Any UL Classified Insulation, any thickness (OPTIONAL) Minimum 7/16" APA Rated OSB or minimum 1.5" HP- NB 1-1/2" 1-1/2" 10 Any UL Classified Insulation, any combination, any thickness Carlisle FR Base Sheet 1" 1" 11 Cellular Lightweight Concrete N/A N/A 1-1/2" 1-1/2" 12 Structural (poured - in-place) concrete N/A N/A 1-1/2" 1-1/2" 600163 - SW Codes « TABLE OF CONTENTS Page 4 of 48 8/2016 Membrane Type: Sure -Weld• (TPO) Mechanically -Fastened or Induction Welding Roofing Systems UL Approval - Combustible - ANSI/UL 790 Spread of Flame Test (Class A) .045" or .060" Sure -Weld Standard Reinforced Membrane (White, Gray or Tan) .045" or .060" Sure -Weld HS Reinforced Membrane (White, Gray or Tan) .080" Sure -Weld EXTRA Reinforced Membrane (White, Gray or Tan) .060" or .080" Spectro-Weld Reinforced Membrane (White) Combustible: 7/16 -in. (minimum) thick non -veneer APA -rated sheathing (oriented strand board panels, structural particleboard panels, composite panels or waferboard panels); 15/32 -in. (minimum) thick plywood 3/4 in. (minimum) wood; Tectum (less than 2" thick) to � erma Bair1 f aseSheet lnsuhtion , w ✓,..... s,.: ^'yy1y4 �"a'n . r ' a. o,..+e ✓ �., nvy Maximum Slope Covet Board 2) SuriWetd SUre Sure -Weld EXTRA liS [z.0 n "� .. ,, .... ?'�'.. , r.. x, 3Y" .� .c .. 9x , ., ., �x .- r. h.,o ... 1 Minimum 1/4" SECUROCK Gypsum Fiber or Glass Mat Roof Boards (1) Any UL Classified Carlisle Polyisocyanurate Insulation, any combination, any thickness. N/A 1/2" 1/2" 2 Minimum 1/4" DensDeck or DensDeck Prime Roof Boards (1) Any UL Classified Carlisle Polyisocyanurate Insulation, any combination, any thickness. N/A 1/2" 1/2" 3 N/A Minimum 3" layer or two layers of 1.5" SecurShield or SecurShield HD Composite. (1x3) N/A 1/2" 1/2" 4 N/A Minimum 2.5" layer SecurShield or SecurShield HD Composite over a 2.5" (minimum) layer of Carlisle HP- H Insulation. (1X4) N/A 1/2" 1/2" 5 Carlisle FR Base Sheet Minimum 1.9" layer of SecurShield or SecurShield HD Composite. (1X4) N/A 1/2" 1/2" 6 N/A Minimum 2.5" layer of any UL Classified Carlisle Polyisocyanurate Insulation, any combination. (1) Minimum 1/2" SecurShield HD or SecurShield HD Plus 1/2" 1/2" 7 Carlisle FR Base Sheet Minimum 1.4" layer of any UL Classified Carlisle Polyisocyanurate Insulation, any combination. (1) Minimum 1/2" SecurShield HD or SecurShield HD Plus 1/2" 1/2" 8 N/A Minimum 1" layer of SecurShield CD. (1)(5) N/A 1/2" 1/2" 9 N/A Minimum 4" layer of any UL Classified EPS Insulation. (1X6) Minimum 1/2" SecurShield HD or SecurShield HD Plus 1/2" 1/2" 10 N/A Minimum 1" layer of SecurShield CD over a minimum 3-1/2" layer of any UL Classified EPS Insulation. (1X6) N/A 1/2" 1/2" I 1 N/A Minimum 1-1/2" layer of Insulfoam HD Composite over a minimum 3" layer of Insulfoam EPS. (1)(6) N/A 1/2" 1/2" 12 N/A Minimum 2" layer of Insulfoam HD Composite over a minimum 2.5" layer of Insulfoam EPS. (1)(6) N/A 1/2" 1/2" 13 N/A Any UL Classified Carlisle Polyisocyanurate Insulation, any combination, any thickness. Minimum 1/4" SECUROCK® Gypsum Fiber Roof Board (1) 3" 3" 14 N/A Any UL Classified Insulation, any thickness (OPTIONAL) 3/8" Minimum psi SECUROCK® Gypsum Fiber Roof Board (1) 3" 3" 15 N/A Any UL Classified Insulation, any thickness (OPTIONAL) Minimum 1/2" SECUROCK® Gypsum Fiber Roof Board (1) 3" 3" 600163 - SW Codes Page 5 of 48 8/2016 • Sure -Weide (TPO) Mechanically -Fastened or Induction Welding Roofing Systems UL Approval - Combustible - ANSI/UL 790 Spread of Flame Test (Class A) .045" or .060" Sure -Weld Standard Reinforced Membrane (White, Gray or Tan) Membrane .045" or .060" Sure -Weld HS Reinforced Membrane (White, Gray or Tan) Type: .080" Sure -Weld EXTRA Reinforced Membrane (White, Gray or Tan) .060" or .080" Spectro-Weid Reinforced Membrane (White) Combustible: 7/16 -in. (minimum) thick non -veneer APA -rated sheathing (oriented strand board panels, structural particleboard panels, composite panels or waferboard panels); 15/32 -in. (minimum) thick plywood 3/4 in. (minimum) wood; Tectum (less than 2" thick) 16 17 18 19 One Ply of Type G2 N/A N/A Three or Two layers of Carlisle FR Base Sheet Any UL Classified Insulation, any thickness (OPTIONAL) Any UL Classified Insulation, any thickness (OPTIONAL) Any UL Classified Insulation, any thickness (OPTIONAL) Any UL Classified Carlisle Polyisocyanurate Insulation, an combinatio . an thickness. Minimum 1/2" SECUROCK® Gypsum Fiber Roof Board (1) Minimum 1/4" SECUROCK® Glass Mat Roof Board (1 Minimum 1/4" Dens Deck/Dens Deck Prime Roof Boards (1) N/A 3" 3"- Sure -Weld 2-1/2"- Sure - Weld EXTRA 3"- Sure -Weld 2-1/2"- Sure - Weld EXTRA 1/2" 3" Unlimited Unlimited 1/2" « TABLE OF CONTENTS 600163 - SW Codes Page 6 of 48 8/2016 Membrane Type: Sure -Weld• (TPO) Mechanically -Fastened or Induction Welding Roofing Systems UL Approval - Combustible - ANSUUL 790 Spread of Flame Test (Class B) .045" or .060" Sure -Weld Standard Reinforced Membrane (White, Gray or Tan) .045" or .060" Sure -Weld HS Reinforced Membrane (White, Gray or Tan) .080" Sure -Weld EXTRA Reinforced Membrane (White, Gray or Tan) .060" or .080" Spectro-Weld Reinforced Membrane (White) Combustible: 7/16 -in. (minimum) thick non -veneer APA -rated sheathing (oriented strand board panels, structural particleboard panels, composite panels or waferboard panels); 15/32 -in. (minimum) thick plywood 3/4 in. (minimum) wood; Tectum (less than 2" thick) 1 2 3 4 N/A N/A N/A One Layer of Carlisle FR Base Sheet Inverted G3 cap sheet Minimum 1.9" layer of SecurShield or SecurShield HD Composite. (7)(8) Minimum 1.4" layer of any UL Classified Carlisle Polyisocyanurate Insulation. (7) Minimum 1" layer of SecurShield CD. (7)(9) Any UL Classified Carlisle Polyisocyanurate Insulation, any combination, any thickness. (OPTIONAL) N/A N/A Minimum 1/2" SecurShield HD or SecurShield HD Plus N/A N/A N/A 1/2" 1/2" 1/2" 1/2" 1/2" 1/2" 1/2" 1/2" 1/2" 1/2" «TABLE OF CONTENTS 600163 - SW Codes Page 7 of 48 8/2016 Sure-Weld•(TPO) Mechanically -Fastened or Induction Welding Roofing Systems UL Approval - Combustible and Non -Combustible - ANSI/UL 790 Spread of Flame Test (Class C) Membrane Type: .045" or .060" Sure -Weld Standard Reinforced Membrane (White, Gray or Tan) .045" or .060" Sure -Weld AS Reinforced Membrane (White, Gray or Tan) .080" Sure -Weld EXTRA Reinforced Membrane (White, Gray or Tan) .060" or .080" Spectro-Weld Reinforced Membrane (White) Combustible: 7/16 -in. (minimum) thick non -veneer APA -rated sheathing (oriented strand board panels, structural particleboard panels, composite panels or waferboard panels); 15/32 -in. (minimum) thick plywood 3/4 in. (minimum) wood; Tectum (less than 2" thick) Non -Combustible: Steel, St. Concrete, Gypsum or Tectum (Min. 2" thick) 1 1 N/A N/A 2" layer of any UL Classified Carlisle Polyisocranurate Isulation Any layer of UL Classified Carlisle Polyisocyanurate Insulation. N/A N/A Unlimited Unlimited Unlimited Unlimited « TABLE OF CONTENTS 600163 - SW Codes Page 8 of 48 8/2016 Membrane Type: Sure -Weld• (TPO) Mechanically -Fastened or Induction Welding Roofing Systems FM Approvals and Equivalencies FM Approval - Field Sheet Securement Criteria (Please see notes 10, 11, 12 and 15) .045" or .060" Sure -Weld Standard Reinforced Membrane (White, Gray or Tan) .045" or .060" Sure -Weld HS Reinforced Membrane (White, Gray or Tan) .080" Sure -Weld EXTRA Reinforced Membrane (White, Gray or Tan) .060" or .080" Spectro-Weld Reinforced Membrane (White) 4 Feet (14) 6 Feet 10 Feet 12 Feet HP-X/Piranha HP -X /Piranha HP -Xtra /Piranha Xtra HP -X /Piranha HP -Xtra /Piranha Xtra HP -X /Piranha HP -Xtra /Piranha Xtra 12" 12" 6" 12" 6" 12" 6" 12" 6" 12" 105 136101-0-0 1-90 392183-0-0 1-75 350392-0-0 1-75 392184-0-0 1-75 350394-0-0 1-75 142996-0-0 1-135 2496-0-0 1.90 12562-0-0 1-90 143000-0-0 1-90 107469-0-0 1-75 107470-0-0 1-90 12788-0-0 1-105 140986-0-0 1-60 140548-0-0 1-120 141023-0-0 106202-0-0 1-75 142983-0-0 1-75 142996-0-0 1-75 106205-0-0 1-75 106197-0-0 1-60 106201-0-0 1-90 12807-0-0 1-120 141042-0-0 1-105 140986-0-0 1-120 141023-0-0 600163 - SW Codes (RoofNAV Number) - directly over Min. 1.5" of Polyiso HP -H or SecurShield « TABLE OF CONTENTS Page 9 of 48 8/2016 FM Approvals — Induction Welding Grid Securement Membrane Type: .045" or .060" Sure -Weld Standard Reinforced Membrane (White, Gray or Tan) .045" or .060" Sure -Weld HS Reinforced Membrane (White, Gray or Tan) .080" Sure -Weld EXTRA Reinforced Membrane (White, Gray or Tan) Min. 22 gauge Grade C Steel Deck Min. 22 gauge Grade E Steel Deck HP-X/lnduction Plate HP-X/RhinoBond 1-90 RhinoBond and 1soWeld HP -X / RhinoBond HP-X/RhinoBond HD 14-10/RhinoBond 1-120 (RhinoBond Only) 1-195 (RhinoBond Only) 16 386367-0-0 8 222375-0-0 16 387161-0-0 14 27 20 40 20 (RhinoBond Only) 1-105 (RhinoBond Only) 8 312569-0-0 8 311967-0-0 FM Approvals - Induction Welding Linear Securement Min. 22 gauge Grade E Steel Deck HP -X RhinoBond 5' 5' 10' 12" 6" 6" 1-75 323353-0-0 1-135 323355-0-0 1-75 323398-0-0 (RoofNAV Number) over Polyiso HP -H « TABLE OF CONTENTS 600163 - SW Codes Page 10 of48 8/2016 90 psf Uplift Resistance Test (1-90 Equivalency on 12' x 24' Table) Wind uplift testing has been completed in accordance with the FM 4470 Teat Procedure which is witnessed and certified by Architectural Testing, Incorporated, an industry recognized Independent Testing Laboratory. Over a 22 gauge Grade E Steel roof deck, the following results were obtained using HP -X Fasteners and Piranha Plates for membrane securement. The Performance Test Report is on file and available from Carlisle. Membrane Type: .045" or .060" Sure-We1dTM Standard Reinforced Membrane (white, gray or tan). Min. 22 gauge 10' See notes 16 and 17. 12" Per Carlisle Specification Per Carlisle Specification « TABLE OF CONTENTS 600163 - SW Codes Page 11 of48 8/2016 Membrane Type: Sure -Weld• (TPO) Mechanically -Fastened or induction Welding Roofing Systems FM Class A Roof Deck Construction and Insulation Approvals (18) .045" or .060" Sure -Weld Standard Reinforced Membrane (White, Gray or Tan) .045" or .060" Sure -Weld HS Reinforced Membrane (White, Gray or Tan) .080" Sure -Weld EXTRA Reinforced Membrane (White, Gray or Tan) .060" or .080" Spectro-Weld Reinforced Membrane (White) New ConstructionJTearoff: Steel (Minimum 22 gauge) Structural Concrete Retrofit (No Tearoff) (21): Structural Concrete Retrofit (No Tearoff) (21): Steel (Minimum 22 gauge) 1/2" (with RecovayBoard or Sccurook overlay) 5" Dens Deck overlay and Sure -Weld Standard) Carlisle HP Recovery Board (min. 1/2"), Dene -Deck min. 1/4") or Securock (min. 1/4") Over: Approved Insulation (20) isocyanura SecurShield Carlisle HP Recovery Board Carlisle Polyisocyanurate HP -H or SecurShield Carlisle SecurShield HD or SecurShield HD Plus 1.5"-12" in./ Refer to FM RoofNAV website 1/2"-1" 1" Max. 1/2" 3" (with Dena -Deck overlay and Sure -Weld EXTRA) 2" (with Recovery Board or Securock overlay) 5" (with Deas -Deck overlay) 1-1/2" 1/2" 2" 1-1/2" « TABLE OF CONTENTS 600163 - SW Codes Page 12 of 48 8/2016 Membrane Type: Sure -Weld• (TPO) Mechanically Fastened or Induction Welding Roofing Systems ANSI-SPRI WD-1/ASCE 7-10 Approvals .045" or .060" Sure -Weld Standard Reinforced Membrane (White, Gray or Tan) .045" or .060" Sure -Weld HS Reinforced Membrane (White, Gray or Tan) .080" Sure -Weld EXTRA Reinforced Membrane (White, Gray or Tan) .060" or .080" Spectro-Weld Reinforced Membrane (White) 6 Feet 10 Feet HPX/Piranha HP -X /Piranha HP -Xtra /Piranha. Xtra HPX /Piranha HP -Xtra /Piranha Xtra IIP -X /Piranha HP -Xtra /Piranha Xtra 12" 12" 1-105 1-90 1-105 1-135 1-120 1-75 6" 9" 12" 6" 12" 1-105 1-75 1-60 1-120 1-60 9„ 1.120 1111111111121111111111 1-60 1-90 1-60 1-60 1-120 1-90 1-75 1-120 1-90* 1-120 1-75 1-75 1-75 1-90 1-75 1-90 *Max 1-75 using Spectro-Weld « TABLE OF CONTENTS 600163 - SW Codes Page 13 of48 8/2016 Sure -Weld• Metal Retrofit Roofing System Underwriters Laboratories (UL) ADDrovals The UL ratings achieved with the Metal Retrofit Roofing System are identical to the approvals listed for the Sure-We1dTM Mechanically -Fastened Roofing System over non-combustible decks depending on the membrane selected. Click here for ratings. FM Approvals As referenced in FM Approvals Loss Prevention Data Sheet 1-31, the method of recovering an existing metal roof system with a single -ply mechanically fastened roofing system where the membrane is secured through the existing metal roof directly to the structural purlins is recognized as an appropriate recovery system when installed per the recommendations of FM. As a standard FM Approvals requirement, additional membrane and insulation securement is necessary in the corner and/or perimeter areas as outlined in FM Property Loss Prevention Data Sheets 1-28. 1-29 and 1-31. These bulletins should be review in their entirety for specific requirements concerning insulation types, fastening enhancements and other items that may be necessary. FM A i royals — Metal Retrofit nitre -Wi=ld ipeetro- 60 Inches 120 Inches 138 Inches HP Purlin/Piranha HP Purlin/Piranha HP Purlin/Piranha 6" 12" 6" 12" 6" 1-135 272454-0-0 1-75 272513-0-0 1-120 272710-0-0 1-60 272642-0-0 1-105 272663-0-0 1-120 1-75 1-75 1-60 1-75 (RoofNAV Number) - For selected systems using 1/4" thick Gypsum top layer. FM Approvals — Metal Retrofit Pressure -Sensitive RUSS Stri 60 Inches 120 Inches HP Purlin/Piranha HP Purlin/Piranha 12" 6" 12" 1-120 272568-0-0 1-120 272563-0-0 1-75 272576-0-0 1-75 1-75 1-60 (RoofNAV Number) - For selected systems using 1/4" thick Gypsum top layer. FM A royals — Induction Weldin Metal Retrofit Structural Steel Purlin (Metal Retrofit) HP Purlin RhinoBond 5' 5' 10' 12" 6" 6" 1-75 373501-0-0 1-135 373505-0-0 1-75 373498-0-0 600163 - SW Codes (RoofNAV Number) - For selected systems using 1/4" thick Gypsum top layer. « TABLE OF CONTENTS Page 14 of 48 8/2016 HP -H, SecurShield, SecurShield HD, SecurShield HD Plus or SecurShield HD Composite- any combination, any thickness Any UL Classified Insulation, any thickness (OPTIONAL) Any UL Classified Insulation, any thickness (OPTIONAL) Any UL Classified Insulation, any thickness (OPTIONAL) Membrane Type: Sure -Weld• (TPO) Adhered Roofing Systems UL Approval - Non -Combustible - ANSI/UL 790 Spread of Flame Test (Class A) .045" or .060" Sure -Weld Standard Reinforced Membrane (White, Gray or Tan) .045" or .060" Sure -Weld HS Reinforced Membrane (White, Gray or Tan) .080" Sure -Weld EXTRA Reinforced Membrane (White, Gray or Tan) .060" or .080" Spectro-Weld Reinforced Membrane (White) Non -Combustible: Steel; St. Concrete; Gypsum; Tectum (Min. 2" thick) 1 2 3 5 7 8 9 11 12 Non - Combustible Cellular Lightweight Concrete Structural (poured -in-place) concrete Any UL Classified EPS or XPS Insulation, any thickness Minimum 1" layer of HP -H, SecurShield, or SecurShield HD Composite over any UL Classified EPS or XPS Insulation, maximum 1.25 pcf, any thickness Insulfoam HD Composite or Insulfoam HD Composite over Insulfoam EPS, any thickness and density. Any UL Classified Insulation, any thickness (OPTIONAL N/A N/A N/A Minimum 1/2" SecurShield HD, SecurShield HD Plus or SecurShield HD Composite N/A N/A Minimum 1/4" SECUROCK® Gypsum -Fiber or Glass Mat Roof Boards Minimum 1/4"" Dens Deck/Dens Deck Prime Roof Boards Minimum 1/2" HP Recov Board Minimum 7/16" APA Rated OSB or minimum 1.5" HP -NB N/A N/A 1/4" 1/4" 1/4" 1/4" 3" 3" 1-1/2" 1-1/2" 3" 3" 1/2" 1/2" 1/2" 1/2" Unlimited w/Dens Deck Prime 3" w/Gypsum-Fiber Unlimited w/Dens Deck Prime 3,, w/Gypsum-Fiber 1" 1" Unlimited Unlimited 1/4" 1/4" 1/4" 1/4" 2-1/2" 2-1/2" 1/4" 1/4" 2-1/2" 2-1/2" 600163 - SW Codes « TABLE OF CONTENTS Page 15 of 48 8/2016 Sure -Weld• (TPO) Adhered Roofing Systems UL Approval - Combustible - ANSI/UL 790 Spread of Flame Test (Class A) .045" or .060" Sure -Weld Standard Reinforced Membrane (White, Gray or Tan) Membrane .045" or .060" Sure -Weld HS Reinforced Membrane (White, Gray or Tan) Type: .080" Sure -Weld EXTRA Reinforced Membrane (White, Gray or Tan) .060" or .080" Spectro-Weld Reinforced Membrane (White) Combustible: 7/16 -in. (minimum) thick non -veneer APA -rated sheathing (oriented strand board panels, structural particleboard panels, composite panels or waferboard panels); 15/32 -in. (minimum) thick plywood 3/4 in. (minimum) wood; Tectum (less than 2" thick) 2 3 5 6 9 10 11 12 13 Minimum 1/4" SECUROCK® Gypsum Fiber or Glass Mat Roof Boards (25) Minimum 1/4" DensDeck or DensDeck Prime Roof Boards (25) N/A N/A Carlisle FR Base Sheet N/A Carlisle FR Base Sheet N/A N/A N/A N/A N/A N/A Any UL Classified Carlisle Polyisocyanurate Insulation, any combination, any thickness. Any UL Classified Carlisle Polyisocyanurate Insulation, any combination, any thickness. Minimum 3" layer or two layers of 1.5" SecurShield or SecurShield HD Composite. (25X27) Minimum 2.5" layer SecurShield or SecurShield HD Composite over a 2.5" (minimum) layer of Carlisle HP - II Insulation. (25X28) Minimum 1.9" layer of SecurShield or SecurShield HD C... ite. 25,28 Minimum 2.5" layer of any UL Classified Carlisle Polyisocyanurate Insulation, any combination. (25) Minimum 1.4" layer of any UL Classified Carlisle Polyisocyanurate Insulation, any combination. (25) Minimum 1" layer of SecurShield CD. (25)(29) Minimum 4" layer of any UL Classified EPS Insulation. (25)(30) Minimum 1" layer of SecurShield CD over a minimum 3-1/2" layer of any UL Classified EPS Insulation. (25)(30 Minimum 1-1/2" layer of Insulfoam HD Composite over a minimum 3" layer of Insulfoam EPS. (25)(30) Minimum 2" layer of Insulfoam HD Composite over a minimum 2.5" layer of Insulfoam EPS. (25)(30) Any UL Classified Carlisle Polyisocyanurate Insulation, any combination, any thickness. N/A N/A N/A N/A N/A Minimum 1/2" SecurShield HD or SecurShield HD Plus Minimum 1/2" SecurShield HD or SecurShield HD Plus N/A Minimum 1/2" SecurShield HD or SecurShicld HD Plus N/A N/A N/A Minimum 1/4" SECUROCK® Gypsum Fiber Roof Board (25) 1/4" 1/4" 1/4" 1/4" 1/4" 1/4" 1/4" 1/4" 1/4" 1/4" 1/4" 1/4" 3" 1/2" 1/2" 1/2" 1/2" 1/2" 1/2" 1/2" 1/2" 1/2" 1/2" 1/2" 1/2" 3" 1/4" 1/4" 1/4" 1/4" 1/4" 1/4" 1/4" 1/4" 1/4" 1/4" 1/4" 1/4" 2-1/2" 600163 - SW Codes Page 16 of 48 8/2016 Sure -Weld* (TPO) Adhered Rooflng Systems UL Approval - Combustible - ANSI/UL 790 Spread of Flame Test (Class A) .045" or .060" Sure -Weld Standard Reinforced Membrane (White, Gray or Tan) Membrane .045" or .060" Sure -Weld HS Reinforced Membrane (White, Gray or Tan) Type: .080" Sure -Weld EXTRA Reinforced Membrane (White, Gray or Tan) .060" or .080" Spectro-Weld Reinforced Membrane (White) Combustible: 7/16 -in. (minimum) thick non -veneer APA -rated sheathing (oriented strand board panels, structural particleboard panels, composite panels or waferboard panels); 15/32 -in. (minimum) thick plywood 3/4 in. (minimum) wood; Tectum (less than 2" thick) 14 15 16 17 18 N/A N/A One Ply of Type G2 N/A N/A Any UL Classified Insulation, any thickness (OPTIONAL) Any UL Classified Insulation, any thickness (OPTIONAL) Any UL Classified Insulation, any thickness (OPTIONAL) Any UL Classified Insulation, any thickness (OPTIONAL) Any UL Classified Insulation, any thickness (OPTIONAL) Minimum 3/8" SECUROCK® Gypsum Fiber Roof Board (25) Minimum 1/2" SECUROCK® Gypsum Fiber Roof Board (25) Minimum 1/2" SECUROCK® Gypsum Fiber Roof Board (25) Minimum 1/4" SECUROCK® Glass Mat Roof Board (25) Minimum 1/4" Dens Deck/Dens Deck Prime Roof Boards 25 3" 3" 3" 3" 3" 3" 3" 3" 3" Unlimited 2-1/2" 2-1/2" 2-1/2" 2-1/2" 2-1/2" « TABLE OF CONTENTS 600163 - SW Codes Page 17 of 48 8/2016 Sure -Weld* (TPO) Adhered Roofing Systems UL Approval - Combustible - ANSI/UL 790 Spread of Flame Test (Class B) Membrane .045" or .060" Sure -Weld Standard Reinforced Membrane (White, Gray or Tan) Type: .045" or .060" Sure -Weld HS Reinforced Membrane (White, Gray or Tan) .080" Sure -Weld EXTRA Reinforced Membrane (White, Gray or Tan) .060" or .080" Spectre -Weld Reinforced Membrane (White) Combustible: 7/16 -in. (minimum) thick non -veneer APA -rated sheathing (oriented strand board panels, structural particleboard panels, composite panels or waferboard panels); 15/32 -in. (minimum) thick plywood 3/4 in. (minimum) wood; Tectum (less than 2" thick) 1 2 N/A N/A N/A One Layer of Carlisle FR Base Sheet Minimum 1.9" layer of SecurShield or SecurShield HD Composite. (31X32) Minimum 1.4" layer of any UL Classified Carlisle Polyisocyanurate Insulation. (31) Minimum 1" layer of SecurShield CD. (31X33) Any UL Classified Carlisle Polyisocyanurate Insulation, any combination, any thickness. N/A Minimum 1/2"" SecurShield HD or SecurShield HD Plus N/A N/A 1/4" 1/4" 1/4" 1/4" 1/2" 1/2" 1/2" 1/2" 1/4" 1/4" 1/4" 1/4" « TABLE OF CONTENTS 600163 - SW Codes Page 18 of 48 8/2016 Sure -Weld* (TPO) Adhered Rooting Systems UL Approval - Combustible and Non -Combustible - ANSI/UL 790 Spread of Flame Test (Class C) Membrane .045" or .060" Sure -Weld Standard Reinforced Membrane (White, Gray or Tan) Type: .045" or .060" Sure -Weld HS Reinforced Membrane (White, Gray or Tan) .080" Sure -Weld EXTRA Reinforced Membrane (White, Gray or Tan) .060" or .080" Spectro-Weld Reinforced Membrane (White) Combustible: 7/16 -in. (minimum) thick non -veneer APA -rated sheathing (oriented strand board panels, structural particleboard panels, composite panels or waferboard panels); 15/32 -in. (minimum) thick plywood 3/4 in. (minimum) wood; Tectum (less than 2" thick) Non -Combustible: Steel, St. Concrete, Gypsum or Tectum (Min. 2" thick) 1 1 N/A N/A 2" layer of any UL Classified Carlisle Polyisocranurate Isulation Any layer of UL Classified Carlisle Polyisocyanurate Insulation. N/A N/A Unlimited Unlimited Unlimited Unlimited Unlimited Unlimited « TABLE OF CONTENTS 600163 - SW Codes Page 19 of 48 8/2016 6" ribbons of FAST Membrane Type: FM Approvals Design "A" Adhered Roofing Systems SecurShield HD Ratings - New Construction .045" or .060" Sure -Weld Standard Reinforced Membrane (White, Gray or Tan) .045" or .060" Sure -Weld HS Reinforced Membrane (White, Gray or Tan) .080" Sure -Weld EXTRA Reinforced Membrane (White, Gray or Tan) .060" or .080" Spectro-Weld Reinforced Membrane (White) 1.5"-11.5" thick of Polyiso HP -H or SecurShield Min. 1.5" Polyiso HP -H or SecurShield 1.5"-12" thick of Polyiso 1 -IP -H 2"-12" thick of Polyiso HP -H 1.5"-12" thick of Polyiso HP -H 1.5"-12" thick of Polyiso HP -H 1.5"-12" thick of Polyiso HP -H Min. 1/2" Dens -Deck Prime or Securock Min. 1/2" Dens -Deck Prime or Securock 1/2" - 36" thick of Polyiso HP -H Min. 1/2" Polyiso HP -H Min. 1/2" Polyiso HP -H Loose laid Loose laid 10 (3.2 sq. ft.) 8 (4 sq. ft) 18(1.8 sq. ft.) 24 (1.33 sq. ft.) 24 (1.33 sq. ft.) 16 (2 sq. ft.) 16 (2 sq. ft.) 12" ribbons of FAST 12" ribbons of Olybond 500 BA Hot Asphalt 1/2" SecurShield HD 1/2" SecurShield HD 1/2" SecurShield HD 1/2" SecurShield HD 1/2" SecurShield HD 1/2" SecurShield HD 1/2" SecurShield HD 1/2" SecurShield HD over Pol 'so HP -H 12 (2.67 sq. ft) 16 (2 sq. ft) 6" ribbons of FAST 6" ribbons of FAST 6" ribbons of Flexible FAST Onl 1-75 1-90 1-90 1-90 1-105 6" ribbons of Flexible FAST Onl 1-150 1/2" SecurShield HD over Pol 'so HP -H 1/2" SecurShield HD 1/2" SecurShield HD 1/2" SecurShield HD 4" ribbons of Flexible FAST Onl 6" ribbons of FAST 12" ribbons of FAST 12" ribbons of Olybond 500 BA Hot Asphalt 1-165 1-90 1-90 1-225 1-240 1-240 353874-0-0 353875-0-0 325939-0-0 LVOC Only 325941-0-0 SWBA Only 325940-0-0 LVOC Only 381226-0-0 295747-0-0 Class A 353916-0-0 Class A SWBA Onl 353917-0-0 Class B LVOC Only 326014-0-0 Class B LVOC Onl 326019-0-0 Class B SWBA Onl 326017-0-0 Class B LVOC Onl 382997-0-0 Class A 296321-0-0 353918-0-0 SWBA Only 353919-0-0 LVOC Only 382998-0-0 600163 - SW Codes Page 20 of 48 8/2016 Membrane Type: FM Approvals Design "A" Adhered Roofing Systems SecurShield HD Ratings - New Construction .045" or .060" Sure -Weld Standard Reinforced Membrane (White, Gray or Tan) .045" or .060" Sure -Weld HS Reinforced Membrane (White, Gray or Tan) .080" Sure -Weld EXTRA Reinforced Membrane (White, Gray or Tan) .060" or .080" Spectro-Weld Reinforced Membrane (White) 1/2" - 36" thick of Polyiso HP -H 1/2" - 36" of Polyiso HP -H or SecurShield 1.5" to 36" thick Min. 1.5" Polyiso HP -H Min. 1.5" Polyiso HP -H Min. 1.5" Polyiso HP -H FM Approved FM Approved Min. 1.5" Polyiso HP -H 12" ribbons of FAST 12" ribbons of FAST Full -Coverage FAST 12" ribbons of Olybond 500 BA 12" ribbons of Olybond 500 BA Loose laid Loose laid 4" ribbons of FAST 1/2" SecurShield HD 1/2" SecurShield HD 1/2" SecurShield HD 1/2" SecurShield HD 1/2" SecurShield HD 1/2" SecurShield HD 1/2" SecurShield HD 1/2" SecurShield HD 1/2" SecurShield HD 1/2" SecurShield HD 1/2" SecurShield HD 12" ribbons of FAST 12" ribbons of FAST Full -Coverage FAST 12" ribbons of Olybond 500 BA 12" ribbons of Olybond 500 BA 12 (2.67 sq. ft) 16 (2 sq. ft) 12 (2.67 sq. ft) 16 (2 sq. ft) 4" ribbons of FAST 4" ribbons of FAST 1-240 Cav-Grip Primer 1-225 Cav-Grip Primer 1-195 702 LV Primer 1-90 702 Primer 1-240 1-150 1-90 1-90 1-75 1-90 1-75 1-90 1-135 1-135 364507-0-0 SWBA Only 364523-0-0 LVOC Only 364526-0-0 SWBA Only 364525-0-0 LVOC Only 392965-0-0 SWBA Only 364508-0-0 Class A SWBA Only 364621-0-0 Class A SWBA Only 364620-0-0 Class A LVOC Onl 392966-0-0 Class A SWBA Only 364509-0-0 SWBA Only 364635-0-0 SWBA Only 364637-0-0 LVOC Only 392967-0-0 SWBA Only 600163 - SW Codes Page 21 of 48 8/2016 Membrane Type: FM Approvals Design "A" Adhered Roofing Systems SecurShield HD Ratings - New Construction .045" or .060" Sure -Weld Standard Reinforced Membrane (White, Gray or Tan) .045" or .060" Sure -Weld HS Reinforced Membrane (White, Gray or Tan) .080" Sure -Weld EXTRA Reinforced Membrane (White, Gray or Tan) .060" or .080" Spectro-Weld Reinforced Membrane (White) Min. 1/2" Polyiso HP -H Min. 1/2" Polyiso HP -H 12" ribbons of FAST 12" ribbons of Olybond 500 BA 1/2" SecurShield HD 1/2" SecurShield HD 1/2" SecurShield HD 1/2" SecnrShieid HD 12" ribbons of FAST 12" ribbons of Olybond 500 BA 12" ribbons of FAST 12" ribbons of Olybond 500 BA 1-240 1-240 1-240 1-240 600163 - SW Codes « TABLE OF CONTENTS Page 22 of 48 8/2016 Membrane Type: FM Approvals Design "A" Adhered Roofmg Systems SecurShield HD Ratings - Recover .045" or .060" Sure -Weld Standard Reinforced Membrane (White, Gray or Tan) .045" or .060" Sure -Weld HS Reinforced Membrane (White, Gray or Tan) .080" Sure -Weld EXTRA Reinforced Membrane (White, Gray or Tan) .060" or .080" Spectro-Weld Reinforced Membrane (White) 6" ribbons of FAST 1/2" SecurShield HD 1/2" SecurShield HD 1/2" SecurShield HD 1/2" SecurShield HD 1/2" SecurShield HD 1/2" SecurShield HD 1/2" SecurShield HD 1/2" SecurShield HD 1/2" SecurShield HD 1/2" SecurShield HD 1/2" SecurShield HD 1/2" SecurShield HD 12 (2.67 sq. ft) 16 (2 sq. ft) 6" ribbons of FAST 4" ribbons of FAST 6" ribbons of FAST 6" ribbons of FAST Full -Coverage FAST 6" ribbons of FAST 4" ribbons of FAST 12" ribbons of Olybond 500 BA 6" ribbons of FAST 12" ribbons of Olybond 500 BA 1-75 1-90 1-90 1-150 1-150 1-150 1-150 1-90 1-150 1-90 1-90 1-90 389428-0-0 386254-0-0 389430-0-0 Class B 386255-0-0 Class A 389429-0-0 • « TABLE OF CONTENTS 600163 - SW Codes Page 23 of 48 8/2016 Membrane Type: FM Approvals Design "A" Adhered Roofing Systems SecurShield HD Plus Ratings - New Construction .045" or .060" Sure -Weld Standard Reinforced Membrane (White, Gray or Tan) .045" or .060" Sure -Weld HS Reinforced Membrane (White, Gray or Tan) .080" Sure -Weld EXTRA Reinforced Membrane (White, Gray or Tan) .060" or .080" Spectro-Weld Reinforced Membrane (White) 1.5"-12" thick of Polyiso HP -H or SecurShield 1.5"-12" thick of Polyiso HP -H or SecurShield 1.5"-12" thick of Polyiso HP -H or SecurShield 1.5"-12" thick of Polyiso HP -H or SecurShield 1.5"- 12" thick of Polyiso HP -H 2"-12" thick of Polyiso HP -H Min. 1.5" Polyiso HP -H Min. 1.5" Polyiso HP -H Min. 1.5" Polyiso HP -H Min. 1/2" Dens -Deck Prime or Securock Min. 1/2" Dens -Deck Prime or Securock 1/2" - 36" thick of Polyiso HP -H Min. 1/2" Polyiso HP -H Min. 1/2" Polyiso HP -H Loose laid Loose laid Loose laid Loose laid 10 (3.2 sq. ft.) 8 (4 sq. ft) 18(1.8 sq. ft.) 24 (1.33 sq. ft.) 24 (1.33 sq. ft.) 16 (2 sq. ft.) 16 (2 sq. ft.) 12" ribbons of FAST 12" ribbons of Olybond 500 BA Hot Asphalt 1/2" SecurShield HD Plus 1/2" SecurShield HD Plus 1/2" SecurShield HD Plus 1/2" SecurShield HD Plus 1/2" SecurShield HD Plus 1/2" SecurShield HD Plus 1/2" SecurShield HD Plus 1/2" SecurShield HD Plus 1/2" SecurShield HD Plus 1/2" SecurShield HD Plus ov Pol 'so HP -H 1/2" SecurShield HD Plus ov Pol 'so HP -H 1/2" SecurShield HD Plus 1/2" SecurShield HD Plus 1/2" SecurShield HD Plus 8 (4 sq. ft) 18(1.8 sq. ft) 24 (1.33 sq. ft) 24 (1.33 sq. ft) 6" ribbons of FAST 6" ribbons of FAST 6" ribbons of FAST 4" ribbons of FAST 4" ribbons of FAST 6" ribbons of FAST 6" ribbons of FAST 12" ribbons of FAST 12" ribbons of Olybond 500 BA Hot Asphalt 1-90 1-120 1-150 1-225 1-90 1-90 1-105 1-150 1-165 1-90 1-90 1-225 1-240 1-240 325933-0-0 325934-0-0 LVOC Only 325936-0-0 SWBA Only 325937-0-0 LVOC Only 353874-0-0 353875-0-0 381226-0-0 326002-0-0 Class B 326005-0-0 Class B LVOC Only 326024-0-0 Class B SWBA Only 326010-0-0 Class B LVOC Only 353916-0-0 Class A SWBA Onl 353917-0-0 Class B LVOC Only 382997-0-0 Class A 353918-0-0 SWBA Only 353919-0-0 LVOC Only 382998-0-0 600163 - SW Codes Page 24 of 48 8/2016 4" ribbons of FAST Membrane Type: FM Approvals Design "A" Adhered Roofing Systems SecurShield HD Plus Ratings - New Construction .045" or .060" Sure -Weld Standard Reinforced Membrane (White, Gray or Tan) .045" or .060" Sure -Weld HS Reinforced Membrane (White, Gray or Tan) .080" Sure -Weld EXTRA Reinforced Membrane (White, Gray or Tan) .060" or .080" Spectro-Weld Reinforced Membrane (White) 1/2" - 36" of Polyiso HP -H or 1/2" - 36" of SecurShield 1/2" - 36" of Polyiso HP -H or 1.5" - 36" of SecurShield Min. 1.5" Polyiso HP -H Min. 1.5" Polyiso HP -H Min. 1.5" Polyiso HP -H Min. 1.5" Polyiso HP -H FM Approved FM Approved Min. 1.5" Polyiso HP -H 12" ribbons of FAST 12" ribbons of FAST Full -Coverage FAST 12" ribbons of Olybond 500 BA Full -Coverage FAST 12" ribbons of Olybond 500 BA Loose laid Loose laid 1/2" SecurShield HD Plus 1/2" SecurShield HD Plus 1/2" SecurShield HD Plus 1/2" SecurShield HD Plus 1/2" SecurShield HD Plus 1/2" SecurShield HD Plus 1/2" SecurShield HD Plus 1/2" SecurShield HD Plus 1/2" SecurShield HD Plus 1/2" SecurShield HD Plus 1/2" SecurShield HD Plus 1/2" SecurShield HD Plus 12" ribbons of FAST 12" ribbons of FAST Full -Coverage FAST 12" ribbons of Olybond 500 BA Vi Full -Coverage FAST 12" ribbons of Olybond 500 BA 12 (2.67 sq. ft) 16 (2 sq. ft) 12 (2.67 sq. ft) 16 (2 sq. ft) 4" ribbons of FAST 4" ribbons of FAST 1-255 Cav-Grip Primer 1-195 702 LV Primer 1-90 702 Primer 1-240 1-150 1-90 1-90 1-90 364507-0-0 SWBA Only 364523-0-0 LVOC 364508-0-0 SWBA Only 364509-0-0 SWBA Only 1-75 1-90 1-75 1-90 1-135 1-135 364526-0-0 SWBA Only 364525-0-0 LVOC 392965-0-0 SWBA Only 364621-0-0 SWBA Onl 364620-0-0 LVOC Onl 392966-0-0 Class A SWBA Only 364635-0-0 LVOC Only 364637-0-0 SWBA Onl 392967-0-0 SWBA Only 600163 - SW Codes Page 25 of 48 8/2016 Membrane Type: FM Approvals Design "A" Adhered Roofing Systems SecurShield HD Plus Ratings - New Construction .045" or .060" Sure -Weld Standard Reinforced Membrane (White, Gray or Tan) .045" or .060" Sure -Weld HS Reinforced Membrane (White, Gray or Tan) .080" Sure -Weld EXTRA Reinforced Membrane (White, Gray or Tan) .060" or .080" Spectra -Weld Reinforced Membrane (White) Min. 1/2" Polyiso HP -H Min. 1/2" Polyiso HP -H 12" ribbons of FAST 12" ribbons of Olybond 500 BA 1/2" SecurShield HD Plus 1/2" SecurShield HD Plus 1/2" SecurShield HD Plus 1/2" SccurShield HD Plus 12" ribbons of FAST 12" ribbons of Olybond 500 BA 12" ribbons of FAST 12" ribbons of Olybond 500 BA 1-315 1-240 1-315 1-240 « TABLE OF CONTENTS 600163 - SW Codes Page 26 of 48 8/2016 Membrane Type: FM Approvals Design "A" Adhered Roofing Systems SecurShield HD Plus Ratings - Recover .045" or .060" Sure -Weld Standard Reinforced Membrane (White, Gray or Tan) .045" or .060" Sure -Weld HS Reinforced Membrane (White, Gray or Tan) .080" Sure -Weld EXTRA Reinforced Membrane (White, Gray or Tan) .060" or .080" Spectro-Weld Reinforced Membrane (White) Min. 1/2" Polyiso HP -H Min. 1.5" Polyiso HP -H Min. 1.5" Polyiso HP -H Min. 1.5" Polyiso HP -H Min. 1.5" Polyiso HP -H 6" ribbons of FAST Full -Coverage FAST 12" ribbons of Olybond 500 BA Full -Coverage FAST 12" ribbons of Olybond 500 BA 1/2" SecurShield HD Plus 1/2" SecurShield HD Plus 1/2" SecurShield HD Plus 1/2" SecurShield HD Plus 1/2" SecurShield HD Plus 1/2" SecurShield HD Plus 1/2" SecurShield HD Plus 1/2" SecurShield HD Plus 1/2" SecurShield HD Plus 8(4 sq. ft) 6" ribbons of FAST 4" ribbons of FAST 6" ribbons of FAST 6" ribbons of FAST Full -Coverage FAST 12" ribbons of Olybond 500 BA Full -Coverage FAST 12" ribbons of Olybond 500 BA 1-90 1-90 1-150 1-150 1-150 1-150 1-90 1-90 1-90 600163 - SW Codes « TABLE OF CONTENTS Page 27 of 48 8/2016 Membrane Type: FM Approvals Design "A" Adhered Roofing Systems Polyiso HP -H Ratings - New Construction .045" or .060" Sure -Weld Standard Reinforced Membrane (White, Gray or Tan) .045" or .060" Sure -Weld HS Reinforced Membrane (White, Gray or Tan) .080" Sure -Weld EXTRA Reinforced Membrane (White, Gray or Tan) .060" or .080" Spectro-Weld Reinforced Membrane (White) 1.5"-12" Polyiso HP -H 2"-12" Polyiso BP -H 2"-12" Polyiso HP -H or SecurShield Min. 1.5" Polyiso HP -H 2" - 8" Polyiso HP -H Min. 1.5" Polyiso HP -H Min. 1.5" Polyiso HP -H Min. 1/2" Dens -Deck Prime or Securock Min. 1/2" Dens Deck Prime or 5/8" Securock 16(2 sq. ft) 8 (4 sq. ft) 20(1.6 sq. ft) 10 (3.2 sq. ft.) 8 (4 sq. ft) 18(1.8 sq. ft.) 24 (1.33 sq. ft.) 16 (2 sq. ft.) 1/2" - 36" Polyiso HP -H 1.5" - 36" Polyiso HP -H 1/2" - 36" Polyiso HP -H 1/2" - 36" Polyiso HP -H 1.5" - 36" Polyiso HP -H 16 (2 sq. ft.) Full Coverage FAST 12" ribbons of FAST 12" ribbons of Olybond 500 BA Hot Asphalt Cave. 12" ribbons of FAST Min. 1.5" Polyiso HP -H Min. 2" Polyiso HP -H Min. 1.5" Polyiso HP -H Min. 1.5" Polyiso HP -H Min. 1.5" Polyiso HP -H Min. 1.5" Polyiso HP -H 12" ribbons of FAST 12" ribbons of FAST 6" ribbons of FAST 4" ribbons of FAST 12" ribbons of FAST 1-90 1-90 1-150 1-90 1-90 1-105 1-165 1-90 13221-0-0 13222-0-0 135476-0-0 SWBA Only 188863-0-0 13256-0-0 Class A 13259-0-0 Class A 135474-0-0 Class A SWBA Onl 188878-0-0 Class A 63400-0-0 63401-0-0 135477-0-0 SWBA Only 188900-0-0 1-105 1-315 1-480 1-315 1-315 1-255 Cav-Grip Primer 1-195 702 LV Primer 1-90 702 Primer 352057-0-0 279654-0-0 222698-0-0 279654-0-0 279654-0-0 orl 275361-0-0 LVOC Onl 279656-0-0 Class A 279656-0-0 Class A 279656-0-0 Class A 279705-0-0 279705-0-0 279705-0-0 600163 - SW Codes Page 28 of 48 8/2016 Membrane Type: FM Approvals Design "A" Adhered Roofing Systems Polyiso HP -H Ratings - New Construction .045" or .060" Sure -Weld Standard Reinforced Membrane (White, Gray or Tan) .045" or .060" Sure -Weld HS Reinforced Membrane (White, Gray or Tan) .080" Sure -Weld EXTRA Reinforced Membrane (White, Gray or Tan) .060" or .080" Spectro-Weld Reinforced Membrane (White) Min. 1/2" Polyiso HP -H 1.5"-12" Polyiso HP -H 2"-12" Polyiso HP -H Min. 1.5" Polyiso HP -H 2"-12" Polyiso HP -H 1.5"-12" Polyiso HP -H or SecurShield 1"-12" Polyiso HP -H 1.5" Polyiso HP -H 2" Polyiso HP -H 2" Polyiso HP -H 12" ribbons of FAST 16(2 sq. ft) Full -Coverage FAST 12" ribbons of Olybond 500 BA 8 (4 sq. ft) Full -Coverage FAST 12" ribbons of Olybond 500 BA 16 (2 sq. ft) 8 (4 sq. ft) 20(1.6 sq. ft) Polyiso HP -H 12" ribbons of FAST 1-330 1-90 1-150 1-90 1-90 1-90 1-90 1-90 1-90 1-150 93418-0-0 211688-0-0 SWBA Only 93423-0-0 144203-0-0 189744-0-0 95300-0-0 Class A 224896-0-0 Class A SWBA Only 95309-0-0 Class A 144202-0-0 Class A 189745-0-0 Class B 93419-0-0 224898-0-0 SWBA Only 144204-0-0 189746-0-0 Celcore 1"-12" Polyiso HP -H 4" ribbons of FAST 1-135 309398-0- 194470 309406-0-194470 Class B 309497-0- 194470 Celcore 1" - 36" Polyiso HP -H 4" ribbons of FAST 1-135 309997-0- 50916 310002-0-50916 Class A 310052-0- 50916 Elasdzell 1" - 36" Polyiso HP -H tapered 12" ribbons of Olybond 500 BA 1-180 93280-0- 50936 96122-0-50936 Class A 93283-0- 50936 600163 - SW Codes « TABLE OF CONTENTS Page 29 of 48 8/2016 J Membrane Type: FM Approvals Design "A" Adhered Roofing Systems Polyiso HP -H Ratings - Recover .045" or .060" Sure -Weld Standard Reinforced Membrane (White, Gray or Tan) .045" or .060" Sure -Weld HS Reinforced Membrane (White, Gray or Tan) .080" Sure -Weld EXTRA Reinforced Membrane (White, Gray or Tan) .060" or .080" Spectro-Weld Reinforced Membrane (White) 1" Polyiso HP -H 1/2"-1" Polyiso HP -H 1/2" Polyiso HP -H 6" ribbons of FAST 12" ribbons of Olybond 500 BA 12" ribbons of FAST 1-90 1-90 1-90 278922-0-0 278923-0-0 Class A 278925-0-0 1" Polyiso HP -H 1" Polyiso HP -H 1" Polyiso HP -H 1" Polyiso HP -H 1" Polyiso HP -H Full -Coverage FAST 12" ribbons of Olybond 500 BA 20(1.6 sq. ft) Full -Coverage FAST 12" ribbons of Olybond 500 BA 1-150 1-90 1-90 1-90 1-90 600163 - SW Codes « TABLE OF CONTENTS Page 30 of 48 8/2016 Membrane Type: FM Approvals Design "A" Adhered Roofing Systems SecurShield Ratings - New Construction .045" or .060" Sure -Weld Standard Reinforced Membrane (White, Gray or Tan) .045" or .060" Sure -Weld HS Reinforced Membrane (White, Gray or Tan) .080" Sure -Weld EXTRA Reinforced Membrane (White, Gray or Tan) .060" or .080" Spectro-Weld Reinforced Membrane (White) 1.5"-12" SecurShield 2"-12" SecurShield 2"-12" SecurShield 2"-12" SecurShield Min. 1.5" Polyiso HP -H 2" to 4" Polyiso HP -H or SecurShield Min. 1.5" Polyiso HP -H Min. 1.5" Polyiso HP -H Min. 1/2" Dens -Deck Prime or Securock Min. 1/2" Dens Deck Prime or 5/8" of Securock Min. 2" SecurShield Min. 2" SecurShield Min. 2" SecurShield Min. 1/2" SecurShield 16(2 sq. ft) 8 (4 sq. ft) 20 (1.6 sq. ft.) 32 (1 sq. ft.) 10 (3.2 sq. ft.) 8 (4 sq. ft) 18 (1.8 sq. ft.) 24 (1.33 sq. ft.) 16 (2 sq. ft.) 16 (2 sq. ft.) 12" ribbons of FAST 12" ribbons of 01 •ond500BA Hot Asphalt 12" ribbons of FAST Min. 1.5" SecurShield 2" - 8" SecurShield Min. 1.5" SecurShield Min. 1.5" SecurShield Min. 1.5" SecurShield 1.5"-36" SecurShield 12" ribbons of FAST 12" ribbons of FAST 6" ribbons of FAST 4" ribbons of FAST 6" ribbons of FAST 12" ribbons of FAST 100 LV Only 1-90 1-90 1-150 1-225 1-90 1-90 1-105 1-165 1-90 1-105 1-225 1-240 1-300 1-255 Cav-Grip Primer 1-195 702 LV Primer 1-90 702 Primer 188569-0-0 188870-0-0 135476-0-0 SWBA Only 245513-0-0 SWBA Onl 254630-0-0 352057-0-0 188591-0-0 Class A 188883-0-0 Class A 135474-0-0 Class A SWBA Only 245509-0-0 SWBA Onl 254633-0-0 188615-0-0 188903-0-0 135477-0-0 SWBA Only 245516-0-0 SWBA Onl 254669-0-0 600163 - SW Codes Page 31 of 48 8/2016 Membrane Type: FM Approvals Design "A" Adhered Roofing Systems SecurShield Ratings - New Construction .045" or .060" Sure -Weld Standard Reinforced Membrane (White, Gray or Tan) .045" or .060" Sure -Weld HS Reinforced Membrane (White, Gray or Tan) .080" Sure -Weld EXTRA Reinforced Membrane (White, Gray or Tan) .060" or .080" Spectro-Weld Reinforced Membrane (Wbite) Min. 1/2" Polyiso HP -H Min. 1.5" SecurShield Min 1.5" SecurShield 12" ribbons of FAST 16 (2 sq. ft) Full -Coverage FAST Min. 2" SecurShield 12" ribbons of FAST 1-330 1-90 1-150 Min. 1.5" SecurShield Min 1.5" SecurShield 16 (2 sq. ft) Full -Coverage FAST 1-90 1-90 2" SecurShield 2" SecurShield Min 1.5" SecurShield Min. 1/2" SecurShield Min. 1/2" SecurShield 20 (1.6 sq. ft.) 32 (1 sq. ft.) 4" ribbons of FAST 12" ribbons of FAST 12" ribbons of 01 •..d500BA 1-150 1-225 1-135 1-180 1-90 600163 - SW Codes « TABLE OF CONTENTS Page 32 of 48 8/2016 FM Approvals Design "A" Adhered Roofing Systems SecurShield Ratings - Recover .045" or .060" Sure -Weld Standard Reinforced Membrane (White, Gray or Tan) .045" or .060" Sure -Weld HS Reinforced Membrane (White, Gray or Tan) Membrane Type: .080" Sure -Weld EXTRA Reinforced Membrane (White, Gray or Tan) .060" or .080" Spectro-Weld Reinforced Membrane (White) 1" SecurShield 1" SecurShield 1" SecurShield 1" SecurShield 1" SecurShield 1" SecurShield 1" SecurShield 20(1.6 sq. ft) 12" ribbons of FAST 20(1.6 sq. ft) Full -Coverage FAST 12" ribbons of Olybond 500 BA 20(1.6 sq. ft) Full -Coverage FAST 12" ribbons of Olybond 500 BA 1-90 1-90 1-150 1-90 1-90 1-90 1-90 « TABLE OF CONTENTS 600163 - SW Codes Page 33 of 48 8/2016 Membrane Type: FM Approvals Design "A" Adhered Rooting Systems Securock Ratings - New Construction .045" or .060" Sure -Weld Standard Reinforced Membrane (White, Gray or Tan) .045" or .060" Sure -Weld HS Reinforced Membrane (White, Gray or Tan) .080" Sure -Weld EXTRA Reinforced Membrane (White, Gray or Tan) .060" or .080" Spectro-Weld Reinforced Membrane (White) 1.5"-12" Polyiso HP -H 1.5"-12" Polyiso HP -H 1.5"-12" Polyiso HP -H 1.5"-12" Polyiso HP -H 1.5"-12" Polyiso HP -H 1.5"-12" Polyiso HP -H 1.5"-12" Polyiso HP -H 1.5"-12" Polyiso HP -H 1"-12" Polyiso HP -H 1.5"-12" Polyiso HP -H 1.5" to 4" Polyiso HP -H Min. 2" Polyiso HP -H Min. 1.5" Polyiso HP -H Min. 1.5" Polyiso HP -H Min. 1/2" Dens -Deck Prime or Securock Min. 1/2" Dens -Deck Prime or 5/8" Securock 1/2" - 36" Polyiso HP -H 1.5" - 36" Polyiso HP -H Min. 1/2" Polyiso HP -H Loose laid Loose laid Loose laid Loose laid Loose laid Loose laid Loose laid Loose laid Loose laid Loose laid 10(3.2 sq. ft.) 8(4 sq. ft) 18(1.8 sq. ft.) 24 (1.33 sq. ft.) 16 (2 sq. ft.) 16 (2 sq. ft.) FAST Full Cove e 12" ribbons of 01...d500BA Hot Asphalt Min. 1/4" Securock Min. 1/4" Securock Min. 3/8" Securock Min. 1/2" Securock Min. 1/2" Securock Min. 1/2" Securock Min. 5/8" Securock Min. 5/8" Securock Min. 1/2" Securock Min. 1/2" Securock 1/4" Securock 1/4" Securock 1/4" Securock 1/4" Securock Min. 1/4" Securock over Min. 1/2" Polyiso HP -H Min. 1/4" Securock over Min. 1/2" Polyiso HP -H 1/4" Securock 1/4" Securock 1/4" Securock 12 (2.66 sq. ft) 10 (3.2 sq. ft) SecurFAST Plate 8 (4 sq. ft) SureFAST Plate 10 (3.2 sq. ft) 8 (4 sq. ft) SecurFAST Plate 6 (5.33 sq. ft) SecurFAST Plate 8 (4 sq. ft) 6(5.33 sq. ft) SecurFAST Plate 20(1.6 sq. ft) 32 (1 sq. ft) 12" ribbons of FAST 12" ribbons of FAST 6" ribbons of FAST 4" ribbons of FAST 12" ribbons of FAST 12" ribbons of FAST FAST Full Coverage 12" ribbons of Olybond 500 BA Hot Asphalt 1-75 1-90 1-90 1-90 1-90 1-75 1-90 1-90 1-150 1-255 1-90 1-90 1-105 1-165 1-105 1-90 1-315 1-240 1-300 269962-0-0 LVOC • . 269985-0-0 269989-0-0 LVOC Onl 269993-0-0 239271-0-0 LVOC Onl 327597-0-0 269964-0-0 LVOC Onl 269986-0-0 LVOC Onl 269990-0-0 LVOC 269994-0-0 239272-0-0 LVOC Onl 301750-0-0 269968-0-0 LVOC Onl 269988-0-0 LVOC Onl 269992-0-0 LVOC Onl 269996-0-0 LVOC Onl 269952-0-0 LVOC Onl 301753-0-0 LVOC Onl 307662-0-0 SWBA Onl 301747-0-0 LVOC Onl 307751-0-0 SWBA Onl 301755-0-0 LVOC Onl 307702-0-0 SWBA Onl 301761-0-0 LVOC Onl 600163 - SW Codes Page 34 of 48 8/2016 Membrane Type: FM Approvals Design "A" Adhered Roofing Systems Securock Ratings - New Construction .045" or .060" Sure -Weld Standard Reinforced Membrane (White, Gray or Tan) .045" or .060" Sure -Weld HS Reinforced Membrane (White, Gray or Tan) .080" Sure -Weld EXTRA Reinforced Membrane (White, Gray or Tan) .060" or .080" Spectro-Weld Reinforced Membrane (White) 1/2" - 36" Polyiso HP -H Min. 1/2" Polyiso HP -H Min. 1.5" Polyiso HP -H Min. 1.5" Polyiso HP -H Min. 1.5" Polyiso HP -H Min. 1.5" Polyiso HP -H FM Approved FM Approved FM Approved FM Approved FM Approved Min. 1.5" Polyiso HP -H 12" ribbons of FAST 12" ribbons of FAST Full -Coverage FAST Full -Coverage FAST 12" ribbons of 01 .. d 500 BA Loose laid Loose laid Loose laid Loose laid Loose laid 4" ribbons of FAST 1/4" Securock 1/4" Securock 1/4" Securock 1/4" Securock 1/4" Securock 1/4" Securock Min. 1/4" Securock Min. 1/2" Securock Min. 5/8" Securock Min. 1/2" Securock Min. 1/2" Securock 1/2 "Securock 12" ribbons of FAST 12" ribbons of FAST Full -Coverage FAST 12" ribbons of Olybond 500 BA Full -Coverage FAST 12" ribbons of Olybond 500 BA 12 (2.67 sq. ft) 10 (3.2 sq. ft) 8 (4 sq. ft) 20 (1.6 sq. ft) 32 (1 sq. ft) 4" ribbons of FAST 1-255 Cav-Grip Primer 1-195 702 LV Primer 1-90 702 Primer 1-330 1-150 1-90 1-90 1-90 1-75 1-90 1-90 1-150 1-225 1-135 333171-0-0 364524-0-0 LVOC Only 286420-0-0 LVOC Only 364616-0-0 LVOC Only 364619-0-0 LVOC Only 285982-0-0 LVOC Only 364627-0-0 LVOC Only 364633-0-0 LVOC Only 600163 - SW Codes Page 35 of 48 8/2016 Membrane Type: FM Approvals Design "A" Adhered Rooting Systems Securock Ratings - New Construction .045" or .060" Sure -Weld Standard Reinforced Membrane (White, Gray or Tan) .045" or .060" Sure -Weld HS Reinforced Membrane (White, Gray or Tan) .080" Sure -Weld EXTRA Reinforced Membrane (White, Gray or Tan) .060" or .080" Spectro-Weld Reinforced Membrane (White) 1" - 36" Polyiso HP -H Min. 1/2" Polyiso HP -H 12" ribbons of FAST 12" ribbons of 01 . and 500 BA Min. 1/4" Securock 1/4" Securock 12" ribbons of FAST 12" ribbons of Olybond 500 BA 1-135 1-240 310009-0-50914 310012-0- 50914 310049-0-50914 « TABLE OF CONTENTS 600163 - SW Codes Page 36 of 48 8/2016 FM Approvals Design "A" Adhered Roofing Systems Securock Ratings - Recover .045" or .060" Sure -Weld Standard Reinforced Membrane (White, Gray or Tan) .045" or .060" Sure -Weld HS Reinforced Membrane (White, Gray or Tan) Membrane Type: .080" Sure -Weld EXTRA Reinforced Membrane (White, Gray or Tan) .060" or .080" Spectro-Weld Reinforced Membrane (White) 1/2" Polyiso HP -H 10 (3.2 sq. ft) 1/4"-1/2" Securock 12" ribbons of FAST or OlyBond 500 BA 1-90 301766-0-0 LVOC Only 288835-0-0 LVOC Only 288837-0-0 LVOC Only « TABLE OF CONTENTS 600163 - SW Codes Page 37 of 48 8/2016 FM Approvals Design "A" Adhered Roofing Systems Dens Deck Prime Ratings - New Construction .045" or .060" Sure -Weld Standard Reinforced Membrane (White, Gray or Tan) .045" or .060" Sure -Weld HS Reinforced Membrane (White, Gray or Tan) Membrane Type: .080" Sure -Weld EXTRA Reinforced Membrane (White, Gray or Tan) .060" or .080" Spectro-Weld Reinforced Membrane (White) 1.5"-12" of Polyiso HP -H or SecurShield 1.5" to 4" of Polyiso HP -H or SecurShield 1.5" of Polyiso HP -H or Securshield Loose laid Loose laid Loose laid Min. 1/4" Dens Deck Prime Min. 1/2" Dens Deck Prime Min. 5/8" Dens Deck Prime 12 (2.67 sq. ft) 10 (3.2 sq. ft) 8 (4 sq. ft) 1-90 1-90 1-90 92102-0-0 92073-0-0 92098-0-0 95279-0-0 95221-0-0 95274-0-0 92103-0-0 92074-0-0 92099-0-0 Min. 1.5" Polyiso HP -H 10 (3.2 sq. ft.) 1/4" Dens Deck Prime 12" bbons of FAST i-90- - , - 12" ribbons of 2" to 12" Polyiso HP -H 8 (4 sq. ft) Min. 1/4" Dens Deck Prime FAST 1-90 188976-0-0 188980-0-0 - Min. 1.5" Polyiso HP -H 18 (1.8 sq. ft.) 1/4" Dens Deck Prime 6" ribbons of FAST 1-105- - - Min. 1.5" Polyiso HP -H 24 (1.33 sq. ft.) 1/4" Dens Deck Prime 4" ribbons of FAST 1 1-165 Min. 1/2" Dens Deck Prime 16 (2 sq. ft.) 1/4" Dens Deck Prime over Min. 1.5" Polyiso HP -H 12" ribbons of FAST 1-90 303447-0-0 303448-0-0 303451-0-0 Min. 1/2" Dens Deck Prime 16(2 sq. ft.) 1/4" Dens Deck over Min. 1/2" 12" ribbons of Pol,yiso HP -H FAST 1-90 327597-0-0 1/2" - 36" Polyiso HP -H 12" ribbons of FAST 1/4" Dens Deck Prime 12" ribbons of FAST 1-315 1.5"-36" Polyiso HP -H 12" ribbons of Olybond 500 BA 1/4" Dens Deck Prime 12" ribbons of Olybond 500 BA 1-240 375399-0-0 378777-0-0 378778-0-0 1.5"-36" Polyiso HP -H Hot Asphalt 1/4" Dens Deck Prime Hot Asphalt r 1-300 224136-0-0 224138-0-0 1/2" - 36" Polyiso HP -H 12" ribbons of FAST Min. 1/4" Dens Deck Prime 12" ribbons of FAST 1-255 Cav-Grip Primer 333171-0-0 1-195 702 LV Primer 1-90 702 Primer 600163 - SW Codes Page 38 of 48 8/2016 FM Approvals Design "A" Adhered Roofing Systems Dens Deck Prime Ratings - New Construction .045" or .060" Sure -Weld Standard Reinforced Membrane (White, Gray or Tan) .045" or .060" Sure -Weld HS Reinforced Membrane (White, Gray or Tan) Membrane Type: .080" Sure -Weld EXTRA Reinforced Membrane (White, Gray or Tan) .060" or .080" Spectro-Weld Reinforced Membrane (White) Min. 1/2" Polyiso HP -H Min. 1.5" Polyiso HP -H 1.5"-12" Polyiso HP -H 1.5" - 4" Polyiso HP -H 1.5" - 4" Polyiso HP -H 1.5"-12" Polyiso HP -H FM Approved FM Approved FM Approved Min. 1.5" Polyiso HP -H 1" - 36" Polyiso HP -H Min. 1/2" Polyiso HP -H 12" ribbons of FAST Full -Coverage FAST 12" ribbons of Olybond 500 BA Full -Coverage FAST 12" ribbons of FAST 12" ribbons of Olybond 500 BA Loose laid Loose laid Loose laid 4" ribbons of FAST 12" ribbons of FAST 12" ribbons of Olybond 500 BA 1/4" Dens Deck Prime 1/4" Dens Deck Prime Min. 1/4" Dens Deck Prime Min. 1/4" Dens Deck Prime Min. 1/4" Dens Deck Prime Min. 1/4" Dens Deck Prime Min. 1/4" Dens Deck Prime Min. 1/2" Dens Deck Prime Min. 5/8" Dens Deck Prime 1/2" Dens Deck Prime Min. 1/4" Dens Deck Prime 1/4" Dens Deck Prime 12" ribbons of FAST Full -Coverage FAST 12" ribbons of Olybond 500 BA Full -Coverage FAST 12" ribbons of FAST 12" ribbons of Olybond 500 BA 12 (2.67 sq. ft) 10 (3.2 sq. ft) 8 (4 sq. ft) 4" ribbons of FAST 12" ribbons of FAST 12" ribbons of Olybond 500 BA 1-330 1-150 1-90 1-90 1-90 1-90 1-90 1-90 1-90 1-135 1-135 1-240 92503-0-0 157790-0-0 173520-0-0 1/2" S1..e 92638-0-0 310009-0-50914 94036-0-0 94046-0-0 310012-0- 50914 92524-0-0 92641-0-0 310049-0-50914 600163 - SW Codes « TABLE OF CONTENTS Page 39 of 48 8/2016 Membrane Type: FM Approvals Design "A" Adhered Roofing Systems Dens Deck Prime Ratings - Recover .045" or .060" Sure -Weld Standard Reinforced Membrane (White, Gray or Tan) .045" or .060" Sure -Weld HS Reinforced Membrane (White, Gray or Tan) .080" Sure -Weld EXTRA Reinforced Membrane (White, Gray or Tan) .060" or .080" Spectro-Weld Reinforced Membrane (White) 1/2"-1" Polyiso HP -H 1.5"-12" Polyiso HP -H 1" to 12" Polyiso HP -H 20(1.6 sq. ft) 20(1.6 sq. ft) Min. 1/4" Dens Deck Prime 1/4" Dens Deck Prime Min. 1/4" Dens Deck Prime Hot Asphalt 1-90 265212-0-0 265212-0-0 Hot Asphalt 1-90 1-90 91885-0-0 265217-0-0 95011-0-0 265218-0-0 91885-0-0 265217-0-0 « TABLE OF CONTENTS 600163 - SW Codes Page 40 of 48 8/2016 Membrane Type: FM Approvals Design "A" Adhered Roofing Systems OSB Ratings - New Construction .045" or .060" Sure -Weld Standard Reinforced Membrane (White, Gray or Tan) .045" or .060" Sure -Weld HS Reinforced Membrane (White, Gray or Tan) .080" Sure -Weld EXTRA Reinforced Membrane (White, Gray or Tan) .060" or .080" Spectro-Weld Reinforced Membrane (White) Ofaximum Stupe 1 Base Laver Fastening lure -Weld or Sure -W )gage insulation Layer ` (see notes 22, 23 op t ynsulatiun op' i er Fastening itattng Specieo-Weld F C RA br 'ct yam y q/�yf )1 /Y') �' 1-1 #.'" RooAV beT' k•r+r` 1.5"-12" Polyiso HP -H `w.iy.. i t .pfl' Loose laid Ov . d� i �. �. Min. 7/16" OSB f^ 17 (1.9 sq. ft) 1-150 dnb'.n �9 yt (G� 13335-0-0 SWBA Only z 13341-0-0 13335-0-0 SWBA Only SWBA Only L t e x +^" N S !: i. d. ,"' z` F Y'° "��- rR -€ .us a fi' Q �. 2"-12" Polyiso HP -H Full -Coverage FAST Min. 7/16" OSB Full -Coverage FAST 1-150 224838-0-0 SWBA Only 224901-0-0 SWBA Only 224838-0-0 SWBA Only Min. 1.5" Polyiso HP -H Full -Coverage FAST 7/16" OSB Full -Coverage FAST 1-90 - - - Min. 1.5" Polyiso HP -I3 12" ribbons of Olybond 500 BA 7/16" OSB 12" ribbons of Olybond 500 BA h90 - - - FM Approved I Loose laid 7/16" OSB 17 (1.8 sq. ft) 1-150 - - 1 - 600163 - SW Codes «TABLE OF CONTENTS Page 41 of 48 8/2016 Membrane Type: FM Approvals Design "A" Adhered Roofing Systems OSB Ratings - Recover .045" or .060" Sure -Weld Standard Reinforced Membrane (White, Gray or Tan) .045" or .060" Sure -Weld HS Reinforced Membrane (White, Gray or Tan) .080" Sure -Weld EXTRA Reinforced Membrane (White, Gray or Tan) .060" or .080" Spectro-Weld Reinforced Membrane (White) «TABLE OF CONTENTS 600163 - SW Codes Page 42 of 48 8/2016 1-90 702 Primer Membrane Type: FM Approvals Design "A" Adhered Roofing Systems HP Recovery Board Ratings - New Construction .045" or .060" Sure -Weld Standard Reinforced Membrane (White, Gray or Tan) .045" or .060" Sure -Weld HS Reinforced Membrane (White, Gray or Tan) .080" Sure -Weld EXTRA Reinforced Membrane (White, Gray or Tan) .060" or .080" Spectro-Weld Reinforced Membrane (White) 1.5"-12" Polyiso HP -H Min. 1.5" Polyiso HP -H Min. 2"-12" Polyiso HP -H Min. 1/2" Dens -Deck Prime Min. 1/2" Dens -Deck Prime or Securock Min. 1/2" Polyiso HP -H 1.5" - 36" Polyiso HP -H 1.5" - 36" Polyiso HP -H Min. 1/2" Polyiso HP -H Min. 1/2" Polyiso HP -H Loose laid 10(3.2sq.ft.) 8 (4 sq. ft) 16 (2 sq. ft.) 16 (2 sq. ft.) 12" ribbons of FAST 12" ribbons of Olybond 500 BA Hot Asphalt 12" ribbons of FAST 12" ribbons of FAST 1/2"-1" HP Recovery Board Min. 1/2" HP Recovery Board 1/2"-1" HP Recovery Board 1/2"-1" HP Recovery Board over 1.5" - 36" Pol 'so HP -H Min. 1/2" HP Recovery Board over Pol 'so HP -H Min. 1/2" HP Recovery Board 1/2"-1" HP Recovery Board 1/2"-l" HP Recovery Board Min. 1/2" HP Recovery Board Min. 1/2" HP Recovery Board 16 (2 sq. ft) 6" ribbons of FAST 12" ribbons of FAST 12" ribbons of FAST 6" ribbons of FAST 12" ribbons of FAST 12" ribbons of Olybond 500 BA Hot Asphalt 12" ribbons of FAST 12" ribbons of FAST 1-90 1-90 1-90 1-90 1-90 1-315 1-240 1-300 1-255 Cav-Grip Primer 1-195 702 LV Primer 1-330 212437-0-0 188976-0-0 303447-0-0 230435-0-0 SWBA Only 224117-0-0 188980-0-0 303448-0-0 230436-0-0 SWBA Only 224118-0-0 188976-0-0 303447-0-0 230435-0-0 SWBA Only 224117-0-0 ddor Low VOC) Min. 1.5" Polyiso HP -H 1.5"-12" Polyiso HP -H Full -Coverage FAST 12" ribbons of Olybond 500 BA Min. 1/2" HP Recovery Board 1/2"- 1.5" HP Recovery Board Full -Coverage FAST 12" ribbons of Olybond 500 BA 1-90 1-90 92503-0-0 94036-0-0 92503-0-0 600163 - SW Codes Page 43 of 48 8/2016 Membrane Type: FM Approvals Design "A" Adhered Roofing Systems HP Recovery Board Ratings - New Construction .045" or .060" Sure -Weld Standard Reinforced Membrane (White, Gray or Tan) .045" or .060" Sure -Weld HS Reinforced Membrane (White, Gray or Tan) .080" Sure -Weld EXTRA Reinforced Membrane (White, Gray or Tan) .060" or .080" Spectro-Weld Reinforced Membrane (White) Base la►ye Fastening e notes 22, 2 1.5" - 4" Polyiso HP -11 1.5"-12" Polyiso HP -H FM Approved Min. 1.5" Polyiso HP -H 1" - 36" Polyiso HP -H Min. 1/2" Polyiso HP -H Full -Coverage FAST 12" ribbons of Olybond 500 BA Loose laid 4" ribbons of FAST 12" ribbons of' FAST 12" ribbons of Olybond 500 BA Min. 1/2" HP Recovery Board Min. 1/2" HP Recovery Board Min. 1/2" HP Recovery Board Min. 1/2" HP Recovery Board Min. .5 HP Recovery Board Min. 1/2" HP Recovery Board Full -Coverage FAST 12" ribbons of Olybond 500 BA 16 (2 sq. ft) 4" ribbons of FAST 12" ribbons of FAST 12" ribbons of Olybond 500 BA 1-90 1-90 1-90 1-90 1-135 1-240 Roof1VAV Number 157790-0-0 91835-0-0 310009-0-50918 94046-0-0 310012-0- 50918 157790-0-0 91835-0-0 310009-0- 50918 600163 - SW Codes « TABLE OF CONTENTS Page 44 of 48 8/2016 Membrane Type: FM Approvals Design "A" Adhered Roofing Systems HP Recovery Board Ratings - Recover .045" or .060" Sure -Weld Standard Reinforced Membrane (White, Gray or Tan) .045" or .060" Sure -Weld HS Reinforced Membrane (White, Gray or Tan) .080" Sure -Weld EXTRA Reinforced Membrane (White, Gray or Tan) .060" or .080" Spectro-Weld Reinforced Membrane (White) 1" to 12" Polyiso HP -H 20 (1.6 sq. ft) 1/2" HP Recovery Board Hot Asphalt 1-90 265217-0-0 265218-0-0 265217-0-0 « TABLE OF CONTENTS 600163 - SW Codes Page 45 of 48 8/2016 F Membrane Type: FM Approvals Design "A" Adhered Roofing Systems Lightweight Insulating Concrete - New Construction .045" or .060" Sure -Weld Standard Reinforced Membrane (White, Gray or Tan) .045" or .060" Sure -Weld HS Reinforced Membrane (White, Gray or Tan) .080" Sure -Weld EXTRA Reinforced Membrane (White, Gray or Tan) .060" or .080" Spectro-Weld Reinforced Membrane (White) Steel Concrete Celcore Elastizell Sure -Weld or Low VOC Bonding A 1-135 1-180 243956-0-194470 1.5" Slope 191311-0-50936 1.5" Slope SWBA Only 173455-0-50936 3/4" Slope SWBA Only 244212-0-194470 3/4" Slope « TABLE OF CONTENTS 600163 - SW Codes Page 46 of 48 8/2016 National, State & City Building Code Approvals Authority Approval Approved Systems ICC - International Code Council Report ESR 1463 "A" and "MF" SBCCI These Code Bodies merged to form ICC as of March 2003 Refer to ICC approval - BOCA - NES — National Evaluation Service, Inc. "A" and "MF" ICBO "A" and "MF" Dade County (South Florida) Approvals Expires August, 2018 Deck Type Acceptance # Lightweight Concrete 14-0626.07 Wood 14-0626.03 Steel 14-0626.02 Structural Concrete 14-0626.05 Cementitious Wood Fiber 14-0626.04 Gypsum 14-0626.08 Recover 14-0626.06 (Using Sure-We1dTM Standard or EXTRA Reinforced Membrane) 1. Sure-We1dTM White and Tan TPO Membranes exceed the requirements for the U.S.E.P.A. ENERGY STAR® Program for reflective roofing materials. 2. Sure-We1dTM TPO Membranes conform to requirements of the U.S.E.P.A. Toxic Leachate Test (40 CFR part 136) performed by an independent analytical laboratory. « TABLE OF CONTENTS Carlisle SynTec, a division of Carlisle Construction Materials Incorporated, P.O. Box 7000, Carlisle, PA 17013 (S00)-4SYNTEC (800-479-6532) Carlisle, Sure -Seal, FleeceBACK FAST and RUSS are Trademarks of Carlisle Corporation Foamular and DuraPink are Trademarks of U.C. Industries, Inc. Hypalon is a Trademark of E.I. du Pont de Nemours &Company, Inc. Dens -Deck is a Trademark of Georgia-Pacific Styrofoam is a Trademark of Dow Chemical Company The contents of this issue represent the applicable information available at the time of publication. The contents of alder issues are no longer accurate due to subsequent changes. 2016 Copyright Carlisle SyaTec, a divlabn of Carlisle Constructions Materlala Incorporated 600163 - SW Codes Page 47 of 48 8/2016 22. Sure -Seal HP fastener/Sure-Seal Insulation plate. Click on one of the following to return to char: SccwShield HD, SecurShield HD Plus, Polyiso HP -H, SecurShield, Senaock, Dens Deck Prime, OSB or HP Recovery RI 23. Insu1FAST fastener/Sure-Seal Insulation plate. Click on one of rhe following to sebum to ebo,t SecurShield HD, SecurShield HD Phu, Polyiso HP -H, SecurShield, Seauock, Ikon Deck Prime, OSB or HP Recovery Board 24. Insu1FAST fastener/SecurFAST Insulation Fastening plate.Clic.k on one of the following to return to chart SecurShield HD, SecurShield HD Plus, Polyiso HP -H, SecurShield, Swami, Dens Deck Prime, OSB or HP Recovery Board • CARLISLE'S SURE -WELD® Reference Notes Mechanically -Fastened or Induction Welding Roofing 1. All insulation joints must be staggered a minimum of 6 inches from the deck joints for from the insulation joints directly below. (return to table) 2. Any roof covering system listed for use over a combustible roof deck can be installed over a non-combustible roof deck and achieve the same classification. (return to table) 3. Any UL Classified Carlisle Polyisocyanurate Insulation, any combination, any thickness may be used below the 3" minimum total thickness of SecurShield or SecurShield HD Composite. (return to table) 4. Any UL Classified Carlisle Polyisocyanurate Insulation, any combination, any thickness may be used below the 1.9" thickness of SecurShield or SecurShield HD Composite. (retum to table) 5. Any UL Classified Carlisle Polyisocyanurate Insulation, any combination, any thickness may be used below the 1" thickness of SecurShield CD. (return to table) 6. Any UL Classified Insulation, any combination, any thickness, may be used below the 4-1/2" minimum total thickness. (return to table) 7. All insulation joints must be staggered a minimum of 6 inches from the deck joints for from the insulation joints directly below. (return to table) 8. Any thickness of UL Classified Carlisle Polyisocyanurate Insulation may be used below the 1.9" thickness of SecurShield or SecurShield HD Composite. (return to table) 9. Any UL Classified insulation, any combination, any thickness, may be used below the SecurShield CD. (return to table) 10. For roof deck construction (new, tear -off or retrofit), approved insulations and maximum roof slopes, click here. (return to table) 11. Refer to Carlisle specifications for minimum requirements regarding sheet widths and fastener spacing. (retum to table) 12. On steel decks, Carlisle HP -X Fasteners and Piranha Plates or HP -Xtra Fasteners and Piranha Xtra Plates are required. On structural concrete decks, CD -10, HP Concrete Spikes or HD 14-10 Fasteners are used with Piranha Plates. (return to table) 13. Testing conducted on FM approved 22 -gauge Grade E Steel decking (ASTM Designation A611 or A653 Grade 80). Refer to FM requirements for deck installation. (click here for FM requirements) (return to table) 14. Ratings achieved using steel decking attached to structural purlins spaced 5' o.c. (return to table) 15. Please reference for ANSI-SPRI WD-1/ASCE 7-10 for non -FM insured projects, click here. (return to table) 16. For roof deck construction (new, tear -off or retrofit), approved insulations and maximum roof slopes, click here. (return to table) 17. On steel decks, Carlisle HP -X Fasteners and Piranha Plates or HP -Xtra Fasteners and Piranha Xtra Plates are required as identified in this chart. On structural concrete decks, CD -10, HP Concrete Spikes or HD 14-10 Fasteners are used with Piranha Plates. (return to table) 18. The fastener spacing for membrane securement is dependent on the deck type, desired wind uplift rating and the Carlisle Fastening Plate and Fastener utilized as identified, click here for more information. (return to table) 19. Insulation shall be fastened in accordance with Carlisle Specifications. (return to table) 20. On steel decks, a thermal barrier of FM approved gypsum board is required under expanded or extruded polystyrene. For specific thermal barrier requirements, refer to FM's RoofNAV web -site. (return to table) 21. Existing roof must be FM Class 1 rated. (return to table) Fasteners/Plates for FM Adhered Roofing System 25. All insulation joints must be staggered a minimum of 6 inches from the deck joints for from the insulation joints directly below. (return to table) 26. Any roof covering system listed for use over a combustible roof deck can be installed over a non-combustible roof deck and achieve the same classification. (return to table) 27. Any UL Classified Carlisle Polyisocyanurate Insulation, any combination, any thickness may be used below the 3" minimum total thickness of SecurShield or SecurShield HD Composite. (return to table) 28. Any UL Classified Carlisle Polyisocyanurate Insulation, any combination, any thickness may be used below the 1.9" thickness of SecurShield or SecurShield HD Composite. (retum to table) 29. Any UL Classified Carlisle Polyisocyanurate Insulation, any combination, any thickness may be used below the 1" thickness of SecurShield CD. (return to table) 30. Any UL Classified Insulation, any combination, any thickness, may be used below the 4-1/2" minimum total thickness. (return to table) 31. All insulation joints must be staggered a minimum of 6 inches from the deck joints for from the insulation joints directly below. (return to table) 32. Any thickness of UL Classified Carlisle Polyisocyanurate Insulation may be used below the 1.9" thickness of SecurShield or SecurShield HD Composite. (return to table) 33. Any UL Classified insulation, any combination, any thickness, may be used below the SecurShield CD. (return to table) «TABLE OF CONTENTS 600163 - SW Codes Page 48 of 48 8/2016 9/29/2017 STEVE BOZORTH 25924 78 AVE S KENT, WA 98032 City of Tukwila Department of Community Development RE: Permit No. D16-0254 CASH & CARRY 230 ANDOVER PARK E Dear Permit Holder: Allan Ekberg, Mayor Jack Pace, Director In reviewing our current records, the above noted permit has not received a final inspection by the City of Tukwila Building Division. Per the International Building Code, International Mechanical Code, Uniform Plumbing Code and/or the National Electric Code, every permit issued by the Building Division under the provisions of these codes shall expire by limitation and become null and void if the building or work authorized by such permit has not begun within 180 days from the issuance date of such permit, or if the building or work authorized by such permit is suspended or abandoned at any time after the work has begun for a period of 180 days. Your permit will expire on 11/7/2017. Based on the above, you are hereby advised to: 1) Call the City of Tukwila Inspection Request Line at 206-438-9350 to schedule for the next or final inspection. Each inspection creates a new 180 day period, provided the inspection shows progress. -or- 2) Submit a written request for permit extension to the Permit Center at least seven(7) days before it is due to expire. Address your extension request to the Building Official and state your reason(s) for the need to extend your permit. The Building Code does allow the Building Official to approve one extension of up to 180 days. If it is determined that your extension request is granted, you will be notified by mail. In the event you do not call for an inspection and/or receive an extension prior to 11/7/2017, your permit will become null and void and any further work on the project will require a new permit and associated fees. Thank you for your cooperation in this matter. Sincerely, Rachelle Ripley Permit Technician File No: D16-0254 6300 Southcenter Boulevard Suite #100 • Tukwila, Washington 98188 • Phone 206-431-3670 • Fax 206-431-3665 5/1/2017 STEVE BOZORTH 25924 78 AVE S KENT, WA 98032 City of Tukwila Department of Community Development RE: Permit No. D16-0254 CASH & CARRY 230 ANDOVER PARK E Dear Permit Holder: Allan Ekberg, Mayor Jack Pace, Director In reviewing our current records, the above noted permit has not received a final inspection by the City of Tukwila Building Division. Per the International Building Code, International Mechanical Code, Uniform Plumbing Code and/or the National Electric Code, every permit issued by the Building Division under the provisions of these codes shall expire by limitation and become null and void if the building or work authorized by such permit has not begun within 180 days from the issuance date of such permit, or if the building or work authorized by such permit is suspended or abandoned at any time after the work has begun for a period of 180 days. Your permit will expire on 6/6/2017. Based on the above, you are hereby advised to: 1) Call the City of Tukwila Inspection Request Line at 206-438-9350 to schedule for the next or final inspection. Each inspection creates a new 180 day period, provided the inspection shows progress. -or- 2) Submit a written request for permit extension to the Permit Center at least seven(7) days before it is due to expire. Address your extension request to the Building Official and state your reason(s) for the need to extend your permit. The Building Code does allow the Building Official to approve one extension of up to 180 days. If it is determined that your extension request is granted, you will be notified by mail. In the event you do not call for an inspection and/or receive an extension prior to 6/6/2017, your permit will become null and void and any further work on the project will require a new permit and associated fees. Thank you for your cooperation in this matter. Sincerely, Bill Rambo Permit Technician File No: D16-0254 6300 Southcenter Boulevard Suite #100 • Tukwila, Washington 98188 • Phone 206-431-3670 • Fax 206-431-3665 3/1/2018 STEVE BOZORTH 25924 78 AVE S KENT, WA 98032 City of Tukwila Department of Community Development RE: Permit No. D16-0254 CASH & CARRY 230 ANDOVER PARK E Dear Permit Holder: Allan Ekberg, Mayor Jack Pace, Director In reviewing our current records, the above noted permit has not received a final inspection by the City of Tukwila Building Division. Per the International Building Code, International Mechanical Code, Uniform Plumbing Code and/or the National Electric Code, every permit issued by the Building Division under the provisions of these codes shall expire by limitation and become null and void if the building or work authorized by such permit has not begun within 180 days from the issuance date of such permit, or if the building or work authorized by such permit is suspended or abandoned at any time after the work has begun for a period of 180 days. Your permit will expire on 4/8/2018. Based on the above, you are hereby advised to: 1) Call the City of Tukwila Inspection Request Line at 206-438-9350 to schedule for the next or fmal inspection. Each inspection creates a new 180 day period, provided the inspection shows progress. -or- 2) Submit a written request for permit extension to the Permit Center at least seven(7) days before it is due to expire. Address your extension request to the Building Official and state your reason(s) for the need to extend your permit. The Building Code does allow the Building Official to approve one extension of up to 180 days. If it is determined that your extension request is granted, you will be notified by mail. In the event you do not call for an inspection and/or receive an extension prior to 4/8/2018, your permit will become null and void and any further work on the project will require a new permit and associated fees. Thank you for your cooperation in this matter. Sincerely, Bill Rambo Permit Technician File No: D16-0254 6300 Southcenter Boulevard Suite #100 • Tukwila, Washington 98188 • Phone 206-431-3670 • Fax 206-431-3665 PERMIT COORD COPY. PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: D16-0254 PROJECT NAME: CASH & CARRY SITE ADDRESS: 230 ANDOVER PARK E X Original Plan Submittal Response to Correction Letter # DATE: 09/15/16 Revision # before Permit Issued Revision # after Permit Issued DEPARTMENTS: 4ding Division C � r Public Works n A.+& AJ/4 q-)-0-40 Fire Prevention Structural Planning Division ❑ Permit Coordinator n N PRELIMINARY REVIEW: Not Applicable ri (no approval/review required) DATE: 09/20/16 Structural Review Required REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: DUE DATE: 10/18/16 Approved Corrections Required n Approved with Conditions ❑ Denied (corrections entered in Reviews) (ie: Zoning Issues) Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: 12/18/2013 FIELDS ROOF SERVICE INC Washington State Department of 4 Labor & Industries Hoene Espanol Contact. Safety & Health Claims & Insurance Search L&I Page 1 of 3 [ ,•c'., ] A -Z Index Help Workplace Rights Trades & Licensing FIELDS ROOF SERVICE INC Owner or tradesperson Principals GILMER, GARY STEVEN, PRESIDENT MANDELAS, MICHAEL J, SECRETARY GOEMAN, DALE JESSE, DIRECTOR PATNODE, TERRY MARK, DIRECTOR GILMER, THOMAS A, PRESIDENT (End: 12/09/2002) PEAK, DUANE, VICE PRESIDENT (End: 12/09/2002) PEPPER, SCOTT, TREASURER (End: 12/09/2002) Doing business as FIELDS ROOF SERVICE INC WA UBI No. 600 125 673 25924 78TH AVE S KENT, WA 98032 253-852-4974 KING County Business type Corporation Governing persons DALE J GOEMAN GARY S GILMER; TERRY J PATNODE; License Verify the contractor's active registration / license / certification (depending on trade) and any past violations. Construction Contractor License specialties ROOFING License no. FIELDRS262L1 Effective — expiration 06/21/1974— 09/25/2017 Bond CBIC Bond account no. SH3047 Active. Meets current requirements. $12,000.00 Received by L&I Effective date 03/01/2008 04/04/2008 Expiration date Until Canceled Insurance Navigators Specialty Insurance $1,000,000.00 Policy no. Help us improve https://secure.lni.wa.gov/verify/Detail.aspx?UBI=600125673&LIC=FIELDRS262L 1 &SAW= 9/26/2016