Loading...
HomeMy WebLinkAboutPermit D16-0260 - WESTERN FOODS - TENANT IMPROVEMENTWESTERN FOODS 641 INDUSTRY DR Dl 6=0260 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-438-9350 Web site: http://www.TukwilaWA.Rov DEVELOPMENT PERMIT Parcel No: 2523049008 Address: 641 INDUSTRY DR Project Name: WESTERN FOODS Owner: Name: NCWP ANDOVER EXECUTIVE PARK Address: 810 NW MARSHALLS ST #300, PORTLAND, WA, 97209 Contact Person: Name: JULIE GLENN Address: 1326 FIFTH AVE SUITE 400, SEATTLE, WA, 98101 Contractor: Name: D P INC GENERAL CONTRACTORS Address: 19936 BALLINGER WAY NE, LAKE FOREST PARK, WA, 98155 License No: DPINCGCO66BU Lender: Permit Number: D16-0260 Issue Date: 12/19/2016 Permit Expires On: 6/17/2017 Phone: (206) 342-0116 Phone: (206) 361-2989 Expiration Date: 1/31/2018 Name: SKANLAN KEMERBARD Address: 617 INDUSTRY DR, TUKWILA, WA, 98188 DESCRIPTION OF WORK: NON STRUCTURAL INTERIOR TENANT IMPROVEMENT INCLUDES NON STRUCTURAL DEMO, NEW PARTITIONS, CASEWORK, DOORS AND FRAMES AND FNIISHES. Public Works ACTIVITY INCLUDES INSTALLATION OF DOMESTIC WATER REDUCED PRESSURE PRINCIPLE ASSEMBLY (RPPA) OUTSIDE THE BUILDING FOR PREMISE ISOLATION. Project Valuation: $203,500.00 Fees Collected: $4,448.60 Type of Fire Protection: Sprinklers: YES Fire Alarm: YES Type of Construction: VB Occupancy per IBC: B Electrical Service Provided by: TUKWILA Water District: TUKWILA Sewer District: TUKWILA ICurrent Codes adopted by the City of Tukwila: I International Building Code Edition: International Residential Code Edition: International Mechanical Code Edition Uniform Plumbing Code Edition: International Fuel Gas Code: Public Works Activities: Channelization/Striping: Curb Cut/Access/Sidewalk: Fire Loop Hydrant: Flood Control Zone: Hauling/Oversize Load: Land Altering: Landscape Irrigation: Sanitary Side Sewer: Sewer Main Extension: Storm Drainage: Street Use: Water Main Extension: 2015 National Electrical Code: 2014 2015 WA Cities Electrical Code: 2014 2015 WAC 296-46B: 2014 2015 WA State Energy Code: 2015 2015 Volumes: Cut: 0 Fill: 0 Number: 0 Water Meter: No Permit Center Authorized Signature: Date: I hearby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this development �per�mitand,�re to, the onclitions attached to this permit. Signature: Date: 1C. PrintName: -Trzy V�:- OV15L Pr (AJC. f This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: The total number of fire extinguishers required for a light hazard occupancy with Class A fire hazards is calculated at one extinguisher for each 3,000 sq. ft. of area. The extinguisher(s) should be of the "all purpose" (2A, 10 B:C) dry chemical type. The travel distance to any extinguisher must be 75' or less. (IFC 906.3) (NFPA 10, 5.4) The total number of fire extinguishers required for an ordinary hazard occupancy with Class A fire hazards is calculated at one extinguisher for each 1,500 sq. ft. of area. The extinguisher(s) should be of the "All Purpose" (3A, 40B:C) dry chemical type. Travel distance to any fire extinguisher must be 75' or less. (IFC 906.3) (NFPA 10, 5.4) 1: Portable fire extinguishers, not housed in cabinets, shall be installed on the hangers or brackets supplied. Hangers or brackets shall be securely anchored to the mounting surface in accordance with the manufacturer's installation instructions. Portable fire extinguishers having a gross weight not exceeding 40 pounds (18 kg) shall be installed so that its top is not more than 5 feet (1524 mm) above the floor. Hand- held portable fire extinguishers having a gross weight exceeding 40 pounds (18 kg) shall be installed so that its top is not more than 3.5 feet (1067 mm) above the floor. The clearance between the floor and the bottom of the installed hand-held extinguishers shall not be less than 4 inches (102 mm). (IFC 906.7 and IFC 906-9) 2: Extinguishers shall be located in conspicuous locations where they will be readily accessible and immediately available for use. These locations shall be along normal paths of travel, unless the fire code official determines that the hazard posed indicates the need for placement away from normal paths of travel. (IFC 906.5) 3: Fire extinguishers require monthly and yearly inspections. They must have a tag or label securely attached that indicates the month and year that the inspection was performed and shall identify the company or person performing the service. Every six years stored pressure extinguishers shall be emptied and subjected to the applicable recharge procedures. If the required monthly and yearly inspections of the fire extinguisher(s) are not accomplished or the inspection tag is not completed, a reputable fire extinguisher service company will be required to conduct these required surveys. (NFPA 10, 7.2, 7.3) 6: Maintain fire extinguisher coverage throughout. 7: Egress doors shall be readily openable from the egress side without the use of a key or special knowledge or effort. (IFC 1008.1.8.3 subsection 2.2) 8: Dead bolts are not allowed on auxiliary exit doors unless the dead bolt is automatically retracted when the door handle is engaged from inside the tenant space. (IFC Chapter 10) 9: Exit hardware and marking shall meet the requirements of the International Fire Code, (IFC Chapter 10) 10: Door handles, pulls, latches, locks and other operating devices on doors required to be accessible by Chapter 11 of the International Building Code shall not require tight grasping, tight pinching or twisting of the wrist to operate. (IFC 1008.1.9.1) 11: Exits and exit access doors shall be marked by an approved exit sign readily visible from any direction of egress travel. Access to exits shall be marked by readily visible exit signs in cases where the exit or,the path of egress travel is not immediately visible to the occupants. Exit sign placement shall be such that no point in an exit access corridor is more than 100 feet (30,480 mm) or the listed viewing distance for the sign, whichever is less, from the nearest visible exit sign. (IFC 1011.1) 12: Every exit sign and directional exit sign shall have plainly legible letters not less than 6 inches (152 mm) high with the principal strokes of the letters not less than 0.75 inch (19.1 mm) wide. The word "EXIT" shall have letters having a width not less than 2 inches (51 mm) wide except the letter "I", and the minimum spacing between letters shall not be less than 0.375 inch (9.5 mm). Signs larger than the minimum established in section 1011.5.1 of the International Fire Code shall have letter widths, strokes and spacing in proportion to their height. The word "EXIT" shall be in high contrast with the background and shall be clearly discernible when the exit sign illumination means is or is not energized. If an arrow is provided as part of the exit sign, the construction shall be such that the arrow direction cannot be readily changed. (lFC 1011.6) 13: Aisles and aisle access ways serving as a portion of the exit access in the means of egress system shall comply with the requirements of this section. Aisles or aisle access ways shall be provided from all occupied portions of the exit access which contain seats, tables, furnishings, displays and similar fixtures or equipment. The required width of aisles shall be unobstructed. (IFC 1017.1) 14: Exit signs shall be illuminated at all times. To ensure continued illumination for a duration of not less than 90 minutes in case of primary power loss, the sign illumination means shall be connected to an emergency power system provided from storage batteries, unit equipment or on-site generator. (IFC 1011.6.3) 15: Emergency lighting facilities shall be arranged to provide initial illumination that is at least an average of 1 foot-candle (11 lux) and a minimum at any point of 0.1 foot-candle (1 lux) measured along the path of egress at floor level. Illumination levels shall be permitted to decline to 0.6 foot-candle (6 lux) average and a minimum at any point of 0.06 foot-candle (0.6 lux) at the end of the emergency lighting time duration. A maximum-to-minimurn illumination u-iiformity ratio of 40 to 1 shall not be exceeded. (IFC 1006.3.1) 19: Fire protection systems shall be maintained in accordance with the original installation standards for that system. Required systems shall be extended, altered or augmented as necessary to maintain and continue protection whenever the building is altered, remodeled or added to. Alterations to fire protection systems shall be done in accordance with applicable standards. (IFC 901.4) 17: Sprinklers shall be installed under fixed obstructions over 4 feet (1.2 m) wide. (NFPA 13-8.6.5.3.3) 16: All new sprinkler systems and all modifications to existing sprinkler systems shall have fire department review and approval of drawings prior to installation or modification. New sprinkler systems and all modifications to sprinkler systems involving more than 50 heads shall have the written approval of Factory Mutual or any fire protection engineer licensed by the State of Washington and approved by the Fire Marshal prior to submittal to the Tukwila Fire Prevention Bureau. No sprinkler work shall commence without approved drawings. (City Ordinance No. 2436). 20: A fire alarm system is required for this project. The fire alarm system shall meet the requirements of N.F.P.A. 72 and City Ordinance #2437. 21: Maintain square foot coverage of detectors per manufacturer's specifications in all areas including: closets, elevator shafts, top of stairwells, etc. (NFPA 72-17.5.3.1) 23: Maintain automatic fire detector coverage per N.F.P.A. 72. Addition/relocation of walls, closets or partitions may require relocating and/or adding automatic fire detectors. 24: Maintain fire alarm system audible/visual notification. Addition/relocation of walls or partitions may require relocation and/or addition of audible/visual notification devices. (City Ordinance #2437) 22: All new fire alarm systems or modifications to existing systems shall have the written approval of The Tukwila Fire Prevention Bureau. No work shall commence until a fire department permit has been obtained. (City Ordinance #2437) (IFC 901.2) 25: An electrical permit from the City of Tukwila Building Department Permit Center (206-431-3670) is required for this project. 26: All electrical work and equipment shall conform strictly to the standards of the National Electrical Code. (N F PA 70) 27: The maximum flame spread class of finish materials used on interior walls and ceilings shall not exceed that set forth in Table No. 803.9 of the International Building Code. 28: New and existing buildings shall have approved address numbers, building numbers or approved building identification placed in a position that is plainly legible and visible from the street or road fronting the property. These numbers shall contrast with their background. Address numbers shall be Arabic numbers or alphabet letters. Numbers shall be a minimum of 4 inches (102mm) high with a minimum stroke width of 0.5 inch (12.7mm). (IFC 505.1) 18: Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (City Ordinances #2436 and #2437) 29: Any overlooked hazardous condition and/or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. 30: These plans were reviewed by Inspector 511. If you have any questions, please call Tukwila Fire Prevention Bureau at (206)575-4407. 31: `BUILDING PERMIT CONDITIONS' 32: Work shall be installed in accordance with the approved construction documents, and any changes made during construction that are not in accordance with the approved construction documents shall be resubmitted for approval. 33: All permits, inspection record card and approved construction documents shall be kept at the site of work and shall be open to inspection by the Building Inspector until final inspection approval is granted. 34: New suspended ceiling grid and light fixture installations shall meet the seismic design requirements for nonstructural components. ASCE 7, Chapter 13. 35: Partition walls shall not be tied to a suspended ceiling grid. All partitions greater than 6 feet in height shall be laterially braced to the building structure. Such bracing shall be independent of any ceiling splay bracing. 36: All construction shall be done in conformance with the Washington State Building Code and the Washington State Energy Code. 37: All food preparation establishments must have Seattle/King County Department of Public Health sign -off prior to opening or doing any food processing. Arrangements for final Health Department inspection shall be made by calling Seattle/King County Department of Public Health, (1-800-325-6165 ext 9-566), at least three working days prior to desired inspection date. On work requiring Health Department approval, it is the contractor's responsibility to have a set of plans approved by the agency on the job site. 38: All rack storage requires a separate permit issued through the City of Tukwila Permit Center. Rack storage over 8 -feet in height shall be anchored or braced to prevent overturning or displacement during seismic events. The design and calculations for the anchorage or bracing shall be prepared by a registered professional engineer licensed in the State of Washington. Periodic special inspection is required during anchorage of storage racks 8 feet or greater in height. 39: There shall be no occupancy of a building until final inspection has been completed and approved by Tukwila building inspector. No exception, 40: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of this requirement. 41: Every occupied space other than enclosed parking garages and buildings used for repair of automobiles shall be ventilated in accordance with the applicable provisions of the International Mechanical Code. 42: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206-431-3670). 43: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center. 44: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 45: All mechanical work'shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431-3670). 46: ***PUBLIC WORKS PERMIT CONDITIONS' 47: Call to schedule mandatory pre -construction meeting with Dave Stuckle, Public Works Inspector, (206) 433- 0179. 48: The applicant or contractor must notify the Public Works Inspector at (206) 433-0179 upon commencement and completion of work at least 24 hours in advance. All inspection requests for utility work must also be made 24 hours in advance. 49: Prior to construction, all utilities in the vicinity shall be field located. NOTE: For City of Tukwila utility locates, call 811 or 1-800-424-5555. 50: Permit is valid between the weekday hours of 7:00 a.m. and 5:00 p.m. only. Coordinate with the Public Works Inspector for any work after 5:00 p.m. and weekends. 51: No work under this permit during weekend hours without prior approval by Public Works. Coordinate with the Public Works Inspector. 52: Work affecting traffic flows shall be closely coordinated with the Public Works Inspector. Traffic Control Plans shall be submitted to the Inspector for prior approval. 53: Flagging, signing and coning shall be in accordance with MUTCD for Traffic Control. Contractor shall provide certified flagmen for traffic control. Sweep or otherwise clean streets to the satisfaction of Public Works each night around hauling route (No flushing allowed). Notify Public Works Inspector before 12:00 Noon on Friday preceding any weekend work. 54: Any material spilled onto any street shall be cleaned up immediately. 55: Clean and remove debris from City catch basin in and around your work zone. Provide adequate temporary access as not to interfere with other vehicle movement or cause trucks to travel over curbs. All vehicles must make a complete stop prior to entering public right-of-way. 56: Temporary erosion control measures shall be implemented as the first order of business to prevent sedimentation off-site or into existing drainage facilities. 57: The RPPA shall be installed per manufacturer's specifications inside a Hotbox/Rock or equal freeze protection enclosure anchored into a minimum 4" thick concrete pad. 58: Prior to final Public Works inspection the RPPA shall be tested by a certified tester and copy of passing backflow test report shall be submitted to the Public Works Project Inspector. Thereafter the RPPA shall be tested annually at owner's expense and backflow test reports submitted to City of Tukwila Water Dept., 600 Minkler Blvd, Tukwila, WA 98188, phone 206 433-1860, fax 206 575-3404. PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 5190 BACKFLOW - WATER 1700 BUILDING FINAL" 0611 EMERGENCY LIGHTING 5200 EROSION MEASURES 1400 FIRE FINAL 0409 FRAMING 0606 GLAZING LATH & GYPSUM 1600 PUBLIC WORKS FINAL 5160 PUBLIC WORKS PRE -CON 0406 SUSPENDED CEILING CITY OF TUKWILA Community Development Department Public Works Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.TukwilaWA.gov Building Permit No. Project No. I Date Application Accepted: Date Application Expires: All (For oJfice use Only) CONSTRUCTION PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. "Please Print" SITE LOCATION King Co Assessor's Tax No.:—D29e?21A0 — 0010 Site Address: U41 IRDUST94 Suite Number: taA I Floor: I Tenant Name: JNfO�" FMQ�a — New Tenant: ..... Yes El..No CONTACT PERSON — person receiving all project communication Name: 3%4AE CIVOW Address: Inp virm pm, UXAUD City: WANA1,*, State: VV N Zip- 41W t Phone%zoW . m Fax. DRY [Email: ktkta (0 IVAN�S 9MM V U 0 1 - GENERAL CONTRACTOR INFORMATION Company Name: Address: City: State: Zip: Phone: Fax: Contr Reg No.. Exp Date: Tukwila Business License No.: H:\Applications\Foi�t%.Applications On Linc\2011 ApplicationsTurnit Application Revised - 8-9-1 l.docx Revised: AttgustMll bit ARCHITECT OF RECORD Company Name: ArchitectNarne. Address: J�no Sin Mr-, 02k&nC44DU City: State! Zip ,%Ao"A/e . *,% Lo k Phone: ,,, 2 - Fax Email: randum @ loyansonw. con ENGINEER OF RECORD Company Name: Engineer Name: Address: City: State: Zip: Phone: Fax: LENDER/BOND ISSUED (required for projects $5,000 or greater per RCW 19.27.095) Name: 4Va)Vkh� Address: koil kNvvl�" IDNVF- City: -MVW I UP', State: W N Zip: Page I of4 BUILDING PERMIT INFORMATION — 206-431-3670 Valuation of Project (contractor's bid price): $ -100 , 000 Existing Building Valuation: Describe the scope of work (please provide detailed information): V�_C-�Uf — — - t,_L, 10 -T-NW\ - (�, JJF_W t�)0:5� Will there be new rack storage? ..... Yes No If yes, a separate permit and plan submittal will be required. LP IProvide All Building Areas in Square Footage Below PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Will there be a change in use? Standard: El ....... Yes ....... No Compact: Handicap: If "yes", explain: FIRE PROTECTION/HAZARDOUS MATERIALS: N....... Sprinklers [� ....... Automatic Fire Alarm El ....... None E] ....... Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? El ....... Yes ....... No If "yes, attach list of inaterials and storage locations on a separate 8-112 " x I I "paper including quantities and Material Safety bata Sheets. SEPTIC SYSTEM ....... On-site Septic System — For on-site septic system, provide 2 copies of a current septic design approved by King County Health Department. H:\Application.�\Fom�-Applications On Linc\2011 ApplicationsTemit Application Rcviscd - 8.9.1 l.docx Revised: August 2011 Page 2 of4 bli Existing Interior Remodel Addition to Existing Structure New Type of Construction per IBC Type of Occupancy per IBC I" Floor 14) V 2'd Floor 3rd Floor Floors thru Basement Accessory Structure* Attached Garage Detached Garage Attached Carport Detached Carport Covered Deck Uncovered Deck PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Will there be a change in use? Standard: El ....... Yes ....... No Compact: Handicap: If "yes", explain: FIRE PROTECTION/HAZARDOUS MATERIALS: N....... Sprinklers [� ....... Automatic Fire Alarm El ....... None E] ....... Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? El ....... Yes ....... No If "yes, attach list of inaterials and storage locations on a separate 8-112 " x I I "paper including quantities and Material Safety bata Sheets. SEPTIC SYSTEM ....... On-site Septic System — For on-site septic system, provide 2 copies of a current septic design approved by King County Health Department. H:\Application.�\Fom�-Applications On Linc\2011 ApplicationsTemit Application Rcviscd - 8.9.1 l.docx Revised: August 2011 Page 2 of4 bli �M PUBLIC WORKS PERMIT INFORMATION — 206-433-0179 Scope of Work (please provide detailed information): Call before you Dig: 811 Please refer to Public Works Bulletin #1 for fees and estimate sheet. Water District TU .. Tukwila E] ... Water District #125 E] Highline El.. Renton F1 ... Water Availability Provided Sewer District .. Tukwila [:]...Valley View Renton E] .. Seattle ... Sewer Use Certificate n ... Sewer Availability Provided Septic System: F] On-site Septic System - For on-site septic system, provide 2 copies of a current septic design approved by King County Health Department. Submitted with Avulication (mark boxes which am F� ... Civil Plans (Maximum Paper Size - 2211 x 3411) F-1 ... Technical Information Report (Storm Drainage) E] Geotechnical Report Ej ... Traffic Impact Analysis F1 ... Bond Insurance Easement(s) Maintenance Agreement(s) E] ... Hold Harmless - (SAO) E] ... Hold Harmless - (ROW) Proposed Activities (mark boxes that apply): El ... Right-of-way Use - Nonprofit for less than 72 hours El Right-of-way Use - Profit for less than 72 hours F-1 ... Right-of-way Use - No Disturbance Right-of-way Use - Potential Disturbance F� ... Construction/Excavation/Fill - Right-of-way Non Right-of-way r_1 F1 ... Total Cut cubic yards F1 ... Total Fill cubic yards E] ... Sanitary Side Sewer ... Cap or Remove Utilities ... Frontage Improvements ... Traffic Control ... Backflow Prevention - Fire Protection Irrigation _ Domestic Water F� .. Work in Flood Zone E] .. Storm Drainage El.. Abandon Septic Tank 0 Curb Cut El Pavement Cut El Looped Fire Line El Grease Interceptor El Channelization E] Trench Excavation E] Utility Undergrounding ... Permanent Water Meter Size... WO # ... Temporary Water Meter Size.. WO # ... Water Only Meter Size ............ WO # ... Deduct Water Meter Size E] ... Sewer Main Extension ............. Public El Private El M ... Water Main Extension ............. Public E] Private n FINANCE INFORMATION Fire Line Size at Property Line F� ... Water El ... Sewer Monthly Service Billina to: Mailing Water Meter Refund/Billing: Mailing Address: Number of Public Fire Hydrant(s) El ... Sewage Treatment H:\Appli�tion.s\Formi-Applicatiomq On Line\2011 ApplicationsTermit Application Revised - 8-9-1 Ldocx Revised: August 2011 bl, Day Telephone: City Day Telephone: city State Zip State Zip Page 3 of 4 PERMIT APPLICATION NOTES — I Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUTLDING Signature: AGENT: Date: " I 'W � w Print Name: "61AUs ('-')LF'N0 Day Telephone: 1A)V - ?YA1 - 011V MailingAddress: Ins 6:�N kue surrytApp SCAMS, WN 416 11) k City State Zip H;\Application.s\Forms-Applications On Linc\2011 ApplictuionsTermit Application Revised -8-9-11.docx Revised: August 2011 Page 4 of 4 bh DESCRIPTIONS PermitTRAK ACCOUNT QUANTITY PAID $2,913.56 D16-0260 Address: 641 INDUSTRY DR Apn:2523049008 $2,913.56 DEVELOPMENT $2,366.10 PERMIT FEE ROOO.322.100.00.00 0.00 $2,361.60 WASHINGTON STATE SURCHARGE B640.237.114 0.00 $4.50 PUBLICWORKS $425.00 BASE APPLICATION FEE ROOO.322.100.00.00 0.00 $250.00 PERMIT ISSUANCE/INSPECTION FEE ROOO.342.400.00.00 0.00 $87.50 CONSTRUCTION PLAN REVIEW ROOO.345.830.00.00 0.00 $87.50 TECHNOLOGY FEE $122.46 TECHNOLOGY FEE TOTAL FEES PAID BY RECEIPT: R10063 ROOO.322.900.04.00 0.00 $122.46 $2,913.56 Date Paid: Monday, December 19, 2016 Paid By: D P INC GENERAL CONTRACTORS Pay Method: CHECK 4079 Printed: Monday, December 19, 2016 11:19 AM lofl Cp- WYSTM, AWK -*ft" Date Paid: Wednesday, September 21, 2016 Paid By: BURGESS DESIGN Pay Method: CHECK 014606 Printed: Wednesday, September 21, 2016 8:39 1 of 1 AM INSPE, Retain a I N 5 1`14efl'O N N 0. NI -P MON RECORD. -62&)o copy with permit �& PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Priject: T f Inspection: voe o 'F30 I av)j Address: 4�q 1 WbC�wv b< Date Called: Special Instructions: Date Wanted a.m. 21z) 7 Phone No: OApproved per applicable codes. E] Corrections required prior to approval. COMMENTS: Inspector: Date: I In h F1 REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Catt to schedule reinspection. INSPECTION RECORD INSPECTION NO. Retain a copy I with permit C CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection RequEft Line (206) 438-9350 Project: vi Type of Inspec.4'an: Address: q goj5 T -r-4 Date Called: —?�Mm—' Special Instructions: Date Wanted: p. MT2. Requester: Phone No: M UU Approved per applicable codes. El Corrections required prior to approval. paid at 6300 Southcenter Blvd., Suite 100. Catl. to schedule reinspection. INSPECTION RECORD. Retain a copy with pe, t INSPECTION NO. PERMIT NO. CITY OF TUKWILA BU ILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project: wallwv 6;� Type of Inspection: J& - I Address: Date Called: Special instructions: Date Wante q 17 p.m. Z/ lRequester/ Phone No: EJApproved per applicable codes. VM Corrections required prior to approval. 141 nspector. 11 F-1 REINSPECTION FEE REQUIRED. Prior to next inspeZtion. fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedute reinspection. -.elk INSPECTION RECORD Retain a copy with permit �X-02Zt INSPenION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Pr ect: OiLhmna Ty—pe of Inspection: 6WJ^ft, Address: I�Lj / ) 6Lbiz)- �-73- Date Called: Special Instructions: Date Wanted: a.m. p.m. Requester: Phone No: REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project: Type ot inspection: AA�-IVRIY fboD 67j)-SA6No0X9 Address: Date Called: 6511 1AID115W PR( Special Instructions: Date Wanted: Q. —M.' 5-;7-8-17 p.m. Requester: tKITCH Phone No: KApproved per applicable codes. Corrections required prior to approval. I nx– -5115110491PAO I Inspector: Date: 3-;2-8 -J7 ZZ2 F-1 REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd., Suite 100. Call. to schedule reinspection. INSPECTION RECORD �F Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd.., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project: It,�45-7XR'1V /i)W T—ype of inspection: //�-77� - 6Y P,5VAI Address: Date Called: 611 141OP-57R1,4R, Special Instructions: Date Wanted: -z7-1-7 I p.m. Requester: I'M I I -e— d Phone No: 266.4 Approved per applicable codes. Corrections required prior to approval. COMMENTS: OWL rpector: I Date* J h7 F-1 REINSPECTION FEE REQUIRED. Prior to next insp6ction, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION RECORD. Retain a copy with permit INSPT-CTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 ProZ'Zect: a 17ZW TypSaLlnspection: I AJ( Address: 14q / / Date Called: Special Instructions: Date WanteA: / I/ / / 7 p.m. lKequestem Phone No: 54Approved per applicable codes. Corrections required prior to approval. L --j - 1:1 I . . paid at 6300 Southcenter Blvd., Suite 100. Cali to schedule reinspection. INSPECTION RECORD Re6in a copy withpermit INSPECTION NUMBER PERMIT NUMBERS CITY OF TUKWILA FIRE DEPARTMENT 206-575-4407 Project: tA/C,57—t79/,-J Type of -Inspection F14, Address: Suite #: Conta t , P rsop: c/0 Special Instructions: Phone No.: �KApproved per applicable codes. 1-1 Corrections required prior to approval. COMMENTS: Sprinklers: Fire Alarm: Aj LAJ pVL On ( 7-0 VZ— Awr4--cVe—b Monitor: C-; Pre -Fire: Permits: Occupancy Type tq--D D plolbc (Ot-b sra-66?r e��A) grzL- ��Aofi--6-IL-ji �9t-rj61rj&? E cvle;�5s &167. L)NT ( L— 6-e-T7C,\3 Needs Shift Inspection: V t > Sprinklers: Fire Alarm: Aj LAJ pVL On ( 7-0 VZ— Hood & Duct:' Monitor: C-; Pre -Fire: Permits: Occupancy Type Inspector: f-07 ') 4-- 1 Date: 14 L -z I I / :7— 1 H rs.: .1 1 [—] $100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. isming Aouress Attn: Company Name: Address: City: State: zip: Word/Inspection Record Form.Doc 3/14/14 T.F.D. Form F.P. 113 INSPECTION RECORD Retain a copy wMth permit INSPECTION NUMBER U /V1 Ft:: 0 �0211 PERMIT NUMBERS CITY OF TUKWILA FIRE DEPARTMENT 206-575-4407 Project: Type of Inspection: Address: Suite #: Contact Person: 11,17(16-6 Special Instructions: Phone No.: % -) Approved per applicable codes. %AC4rTrt1Q= qUired prior to approval. COMMENTS: Sprinklers: A/ LI) - .......................... ....... . .......... . ..... Hood & Duct C7 y Monitor: Pre -Fire: r/ 4,E Te e-77CPJ 06-V 6 OccupancyType: 7Ht?-U FAR0 15 P-t-62U(12-tTV) ......... 2 ft-r� a e /z, 6 - Needs Shift Inspection: Sprinklers: A/ LI) - Fire Alarm: IJW /00�,A i 7-o Hood & Duct C7 y Monitor: Pre -Fire: Permits: OccupancyType: Inspecto r: Date: H rs.: F] $100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. milling AGaress Attn: Company Name: Address: City: state: zip: Word/Inspection Record Form.Doc 3/14/14 T.F.D. Form F.P. 113 2015 Washinaton State Enerav Code Comoliance Forms for Commercial Buildinqs includinq R2, R3, R4 over 3 stories and all R1 RevjaCd.Am&st 2016 Project Info Project Title: 1 - This title will copy onto other forms 20 r ir-NNEDOOK _ 6 Compliance Applicant Information. Provide contact information for individual who can 7F r'AIAMftq"K;t to inquiries about compliance form information U%J forms do not respond provided. 4 ipn require a password to Company Name: Western Foods APPRO"J -- use. Instructional and Company Address: 641 Industry Drive, Tukwila WA 4oV 2 2 2016 calculating cells Applicant Name: Julie Glenn/Burgess Design are write - protected. Applicant Phone: 206.342.0116 Applicant Email: julieg@burgesspnw.com ritv Of -rukwila Project Description Eit) I L D I IN G. Z 5 =1u 1 E] New Building E] Addition Alt raebJILDIN Include PROJ-SUM form (included in envelope forms wo�r boo I ighting comptliance forms. Building Additions Compliance Method Interior lighting Exterior lighting Lighting systems in addition area comply with all applicable provisions as a stand alone new construction project Refer to Section C502.2.6 for additional requirements. Lighting systems in addition are combined with existing building lighting systems to demonstrate compliance Sr"111110 Addition is combined with existing: L For interior lighting projects, include new + existing interior lighting fixture wattage in Proposed Lighting "A Wattage table in L TG -INT -BLD or L TG -INT -SPA CE form. For exterior lighting projects, include new + existing exterior lighting fixture wattage in Proposed Tradable and Proposed Non- Tradable Lighting Wattage tables in LTG -EXT form. Interior and Exterior Lighting Power Interior lighting Parking garage Exterior lighting Lighting Alterations 50% or more of existing are replaced E] 1:1 Select all Lighting Power and Lighting Control elements that apply to the scope Less than 50% of existing are replaced El 1:1 of the retrofit project. If project includes a combination of spaces where less than Lamp and/or ballast replacement only 50% of the existing fixtures are replaced — existing total wattage not increased in some spaces, and 50% or more of the 50% or more replaced - Total lighting power of new + existing -to -remain fixtures shall comply with total fixtures are replaced in others, then LPA per Sections C405.4.2 and C405.5.2. Include new + existing -to -remain fixtures in Proposed provide separate lighting power Lighting Wattage table in L TG -INT -BLD, L TG -INT -SPA CE or L TG -EXT form. compliance forms for the two retrofit conditions. Spaces undergoing the same Less than 50% replaced - Total lighting power of new + existing -to -remain fixtures shall not exceed the type of retrofit may be combined into one total lighting power prior to alteration. Include new+ existing -to -remain fixtures in the Proposed lighting power compliance form. Lighting Wattage table in LTG -INT -BLD, LTG -INT -SPACE or L TG -EXT form. 50% threshold applies to number of luminaires for interior spaces and parking garages, and total Refer to Section C503.6 for additional installed wattage for exterior luminaires. requirements. Lighting Controls Interior lighting Parking garage Exterior lighting All alteration lighting controls shall be New wiring installed to serve added commissioned per C408.3. fixtures and/or fixtures relocated to new circuit(s) RECEIVED New or moved lighting panel ITY OF TUKWILA Interior is space reconfigured - luminaires unchanged or relocated OCT 24 2016 New wiring or circuit - For interior lighting, provide required manual controls per C405.2.3, occupancy sensor controls per C405.2. 1, daylight responsive controls per C405.2.4 and application specific lighting ,F,�Jo,chanjqes are being made to PV_ controls per C405.2.5. For exterior lighting, provide required controls per C405.2.7. New or moved panel - Provide all applicable lighting controls as noted for New Wiring and automatic fighting E Sys s anVexYMP:�ace time switch controls per C405.2.2. uses and configuration are not Reconfigured interior space - Provide all required lighting controls that apply to a new interior space. changed. Application specific lighting control provisions per C405.2.5 do not apply to reconfigured spaces. Change of Space Use Existing interior lighting systems in areas under -going a change in space use are upgraded to comply with LPAs for the new space types per Tables C405.4.2(l) or C405.4.2(2). Identify interior spaces requiring LPD upgrade to the current Code in Proposed Lighting Wattage table in L TG -INT -BLD or LTG -INT -SPACE form. CORRECTION 04Z 0 LTR# --A 'Lighting Summary, cont. LGT-SUM 9nlri Waqhinatnn State Fnerov Code CornDliance Forms for Commercial Buildinas includinq R2, R3, R4 over 3 stories and all R1 Revised August 2016 Project Title; Fill this line out at top of LGT-SUM -- FDate 10/21/2016 Interior Lighting System Replacing suspended linear fixtures, and standard 2x4 & W fixtures throughout suite. Description Providing new task lighting at training room and hallways, where linear fixtures do not fit with layout. Provide emergency lighting to meet I BC 107.2.3 as required. See A.213.2 for approximate layout. Interior Lighting Power []Building Area Method space -by -space method Allowance Method Select method used in project. Interior Lighting Controls All C405.2.1 - C405.2.8 Controls C405.2 Exception 5 Luminaire Level Lighting Control (LLLC) F] Additional Efficiency Package Option C406.4 Enhanced digital lighting controls To comply with C406.4, no less than 90% of the total installed interior lighting power shall comply with thE required controls per C406.4. Dwelling Unit Interior Permanently installed interior lighting fixtures in dwelling units comply with: Lighting OC405.2 thru C405.5 Commercial Lighting Controls and LPA OC406.3 High Efficacy Lighting 0 Exterior Lighting System Description ,interior Lighting - Space -By -Space Method LTG -INT -SPACE 2015 Washinoton State Enerqy Code Compliance Forms for Commercial Buildings including R2, R3, R4 over 3 stories and all R1 Revised August 2016 Project Title: Fill this line out on LGT-SUM Number of Fixtures Date 10/21/2016 Calculation 0 0 Addition - 0 Addition For Building Department Use Area NOTE 9 stand alone + existing 48 Assembly Small Pendant 3 16 0 Spaces where < 50% of (§) Spaces where ? 50% of 0 192 Office Suspended 8' LED Fixture 20 28 luminaires are replaced luminaires are replaced Office Suspended 4' LED Fixture 1 14 14 LPA Standard 0 Additional Efficiency Package Option 0 Calculation C406.3 Reduced Interior Lighting Power To comply with C406.3, the Proposed LPD shall be 25% lower than the Target LPA. ,Type Refer to C406.3 for additional requirements. Interior Lighting Power Allowance Maximum Allowed Lighting Wattage""' co Location (plan #, Height""' Gross Interior Allowed Watts Allowed room #) Space Type 2 Area in ft2 Watts per ft2 (wattS/f12 x area) Suite 641 Office: Open plan 13 2547 0.842 2146 Suite 641 Warehouse: Smaller, hand carried items 13 2660 0.760 2022 Suite 641 Restroom: all other 8 275 0.780 215 Suite 641 Classroom/lecture/training 13 1182 1.000 1182 Total Area 6664 Retail Display Allowance from LTG -INT -DISPLAY Lobby Art/Exhibit Display Allowance from LTG -INT -DISPLAY NOTE 8 Allowed Watts 5564 Proposed Lighting Wattage Nult: 3 Location (plan #, room #) Fixture Description NOTE 4, 5, 6 Number of Fixtures Watts/ Fixture NOTE 7 1 Watts Proposed Office/Assem. 2x4 Fluorescent Fixture 24 96 2304 Rest/Misc. Recessed Can/Wall Washer 10 32 320 Restroom Restroorn wall mounted Vanity 4 12 48 Assembly Small Pendant 3 16 48 Training Alternate Large Pendant 6 32 192 Office Suspended 8' LED Fixture 20 28 560 Office Suspended 4' LED Fixture 1 14 14 Warehouse Suspended 8' Fluorescent Fixture 20 64 1280 Proposed Retail Display Lighting from LTG -INT -DISPLAY Total Proposed Watts may not exceed Total Allowed Watts for Interior Lighting Total Proposed Wattsl 4766 Interior Lighting Power Allowance co Note I - List all unique space types per Table C405.4.2(2) that occur in the project scope. Select space type category per from drop down menu. Note 2 - Indicate ceiling height for atriums and spaces utilizing the ceiling height adjustment per Table C405.4.2(2), Footnotes d thru f Note 3 - List all proposed lighting Fixtures including exempt lighting equipment and existing -to -remain fixtures. Note 4 - For proposed Fixture Description, indicate fixture type, lamp type (e.g. T-8), number of lamps in the fixture, and ballast type (if included). For track lighting, list the length of the track (in feet) in addition to the fixture, lamp, and ballast information. Note 5 - For lighting equipment eligible for exemption per C405.4. 1, note exception number and leave WattslFixture blank. Note 6 - Existing -to -remain fixtures shall be included in the Proposed Lighting Wattage table in the same manner as new fixtures. Identify as existing in fixture descnption. Note 7 - For proposed WattslFixture enter the luminaire wattage for installed lamp and ballast using manufacturer or other approved source. For luminaires with screw-in lamps, enter the manufacturer's listed maximum input wattage of the fixture (not the lamp wattage). For low voltage lighting, enter the wattage of the transformer For line voltage tracklbusway systems, enter the larger of the attached luminaire wattage or 50 wattsoqineal foot, or enter the wattage limit of permanent current limiting device. Note 8 - Lobby ArtlExhibit Display Allowance is independent of the Maximum Allowed Lighting Wattage. Note 9 - Calculation Area Details: a. Lighting fixtures in a building addition may comply as a stand alone project, or they may be combined with the overall existing building lighting systems to demonstrate compliance. Refer to C502. 1. b. For alterations and building additions, provide Space Types and gross interior areas in the Maximum Allowed Lighting Wattage table. If a building addition will comply as combined with the overall existing building lighting systems, include all applicable existing Space Types and gross interior areas. c. If less than 50% of existing lighting fixtures will be replaced, provide total existing lighting wattage (prior to alteration) in the space provided 1 L: r lans have been reviewed by C-= Works Department for conformance with. c, rLCity standards. Acceptance is subject to er omissions which do not authorize violations of adopted standards or ordinances. The responsibility for the adequac— of the design rests totally with the designer. Additions, deletions or revisions to these drawings after this date will void this acceptance and will require a resubmittal, of revised drawings for subsequent approval. Final acceptance is subject to field inspection by the Public Works utilities inspector. Date: BT. 1-7 k&QJG CORRECTION A I I PT C'M k" bRTPi I L osoz& 0 C -(TY OF 1-U 14W I LO) WS-ZI A REVIEV,---------- VED FOR CODE COMPLIANCE APPROVED NOV 2 2 2016 C'ty Of TUI(Wila BUILDING DIVISION RECEIVED CITY OF TUKWILA NUV 17 2016 PERMIT CENTER ES-957/957N/957Z V� &`Health Hazard Aiolicai iis Job Name - Job Location Engineer — Approval — left berliews. 9A.57, 9,915,7N, 9757Z Reduced Pressure Zone Assemblies Sizes: 21/2" - 10" (65 - 250 mm) Series 957, 957N, 957Z Reduced Pressure Zone Assemblies provide protection to the potable water system from contamination in ac- cordance with national plumbing codes. Series 957, 957N, 957Z are normally used in health hazard applications for protection against backsiphonage or backpressure. Features * 21/2", 3" and 4" (65, 80 and 100mm) sizes available with quarter -turn ball valve shutoffs * Replaceable check disc rubber 0 Extremely compact design 0 70% Lighter than traditional designs 0 304 (Schedule 40) stainless steel housing & sleeve 9 Groove fittings allow integral pipeline adjustment * Patented torsion spring checks provide lowest pressure loss e Unmatched ease of serviceability • Bottom mounted cast stainless steel relief valve • Available with grooved butterfly valve shutoffs Specifications The Reduced Pressure Zone Assembly shall consist of two indepen- dent torsion spring check modules, a differential pressure relief valve located between and below the two modules, two drip tight shutoff valves, and required torsion spring check modules and relief valve shall be contained with a sleeve accessible single housing con- structed from 304 (Schedule 40) stainless steel pipe with groove end connections. Torsion spring checks shall have replaceable elastomer discs and in operation produce drip tight closure against the reverse flow of liquid caused by backpressure or backsiphonage. Assembly shall be a Watts Regulator Company Series 957, 957N, 957Z, IT1011101M Inquire with governing authorities for local installation requirements *The wetted surface of this product contacted by consumable water contains less than 0.25% of lead by weight. Contractor Approval Contractor's P.O. No. Representative — 0 9570SY RECEIVED CITY OF TUKWILA 957ZBFG NOV 17 2016 140 CENTER � ) 957QT CORRECTION NVITIMMM Nftcof I-TR#-2,� The information contained herein is not intended to replace the full product installation and safety information available or the experience of a trained product installer. You are required to thoroughly read all installation instructions and product safety information before beginning the installation of this product. Watts product specifications in U.S. customary units and metric are approximate and are provided for reference only. For precise measurements, please contact Watts Technical Service. Watts reserves the right to change or modify product design, construction, specifications, or materials with- IMWAM out prior notice and without incurring any obligation to make such changes and modifications on Watts products previously or subsequently sold. t) t 1*-- 0402-00 Available Models Suffix: NRS - non -rising stem, resilient seated gate valves OSY - UUFM outside stem and yoke resilient seated gate valves BFG - UUFM grooved gear operated butterfly valves with tamper switch QT - 21/2" - 4" (65 - 1 00mm) quarter -turn ball valves **OSY FxG - Flanged inlet gate connection and grooved outlet gate connection **OSY GxF - Grooved inlet gate connection and flanged outlet gate connection **OSY GxG - Grooved inlet gate connection and grooved outlet gate connection Available with grooved NRS gate valves - consult factory - Post indicator plate and operating nut available - consult factory - **Consult factory for dimensions When installing a drain line on Series 957 backflow, preventers, use 957AG air gaps, See ES-AG/EL/TC for additional information. Dimensions — Weight Materials Housing & Sleeve: 304 (Schedule 40) Stainless Steel Elastomers: EPDM, Silicone and Buna-N Torsion Spring Checks: Nory10, Stainless Steel Check Discs: Reversible Silicone or EPDM Test Cocks: Bronze Body Nickel Plated Pins & Fasteners: 300 Series Stainless Steel Springs: Stainless Steel Pressure — Temperature Temperature Range: 33'F - 140'F (0.5'C - 60'C) Maximum Working Pressure: 175psi (112.1 bar) 957, 957N, 957Z SIZE (DN) (DN) DIMENSIONS WEIGHT in. min A in. C (OSY) min in. mm C (NRS) D G H I in. mm in. mm in. min in. min in. mm i M in. infn In, MIT) P 117NII 11701Y � 1171 NRI � 1171 ISY in. min lbs. kgs. lbs. , lbs. kgs. 21/2 65 303/4 781 1 63/a 416 93/8 238 61/2 165 291/16 738 211/2 546 151/2 393 811/16 223 211/4 540 93/16 234 118 54 128 581126 57 136 62 3 80 311/4 806 181/8 479 10114 260 611/16 170 301/4 768 221/4 565 171/8 435 93/16 233 23 584 101/2 267 134 61 148 67 147 67 161 73 4 100 331/4 857 223/4 578 123/16 310 7 178 33 838 231/2 597 181/2 470 9 1/16 252 261/4 667 113/16 284 164 74 164 74 187 85 187 85 6 — I bU I U Y2 11Ub 301/8 765 16 406 81/2 216 441/4 11371351/4 895 233/16 589 131/16 332 341/4 870 15 381 276 125 298 135 317 144 339 154 8 20OT491/4 864 1264 373/4 959 1915/,6 506 911/16 246 541/8 13751401/8 1019 277/16 697 1511/16 3991 361/8 937 173/16 4371441 200 483 219 516 234 558 253 10 2501573/4 540 1467 453/4 1162 2 313/16 605 113/16 285 66 16761491/2 1257 321/2 826 1 A/1 6 4401441/2 1124 20 5081723 328 783 355 893 405 950 431 I H----------------- t G - 957NBFG, 957ZBFG j 11 , rim L : . j SIZE (DN) DIMENSIONS WEIGHT in. MIR in. G min H In, 171171 I in. min in. Min M in. MM P in. MM 957N/957Z lbs. kgs, 21/2 65 321/2 826 23 584 151/2 394 91/2 241 193/4 502 11 '3/16 300 67 30 3 80 34 864 24 610 16'/16 414 101/16 256 211/4 540 121/8 308 70 32 4 100 351/8 905 1 251/2 648 1 173/16 437 1 10'1/16 279 1 231/2 597 125/8 321 1 87 39 6 150 461/2 1181 1 351/4 895 1 201/2 521 1 131/2 343 1 271/4 692 15 382 1 160 73 NorylO is a registered trademark of SABIC Innovative Plastics Holding BV. h I Approvals 9 Approved by the Foundation for Cross- Connection Control and Hydraulic Research at The University of Southern Califor- nia (FCCCHR-USC) For additional approval information please contact the factory or visit our website at www.amesfirewater.com FM UQDL s _ � (N �F' (9 ccous C@ Approved 1013 B64.4 (**BFG & OSY Only) 1;9#Q Dimensions — Weight continued I------------------------------------- ____ A ---------------------------------------------- ] 957 BFG SIZE (DN) DIMENSIONS WEIGHT in. MM in. MM in. i . n. MM I i . n. MM IbS. kgs. 4 100 29 737 — 7Y4 197 1 6N 162--f— 91/, 241 66 30 6 150 361h 927 9 '1/16 246 1 71/,� 189 1 1411, q69 199 55 nr--n C M D ---------------- H ----------------- ------------------- A ---------------------- P ------ ----------------------- G --------------------- 9570T A I C I D I G I H I I I i M P Pi Or w in. mm in. MM in, M in. mm I in. mm I in. mm I in. mm I in. mm in. mm in. mm in, m 1b,. kq,. lt�'. kg, 21/2 65 271/2 698 47/8 124 67/8 175 1 301/4 7681 211/2 5461 161/16 4071 113/8 289 119718 505 111 Yi6 287 111/16 2871 46 21 57 26 3 80 28 711 47/8 124 6' '/8 175 1 301/4 7681 221/4 5651 169/16 4201 113/8 289 1 207/8 531 1 115/16 287 1115/16 2871 56 25 1 67 30 Capacity Series 957, 957N, 957Z flow curves as tested by Underwriters Laboratory. Flow characteristics collected using butterfly shutoff valves - Horizontal - N-Pattem ----- Z -Pattern psi 18 16 9 14 12 10 8 6 psi 16 14 2 12 LE 10 8 6 psi 26 22 18 E r3 14 10 6 psi 25 20 15 10 5 0 0 0 Z41' (65mm) Service Flow Rated Flow 50 100 150 200 190 380 570 760 7.5 15 3" (80mm) Service Flow Rated Flow 0 100 200 0 380 760 7.5 *111. Rated Flow z N H 250 300 350 gpm 950 1140 1330 Ipm fps *UL Rated Flow 300 400 1140 1520 15 4" (100mm) Service Flow Rated Flow Flow capacity chart identifies valve performance based upon rated water velocity up to 25fps • Service Flow is typically determined by a rated velocity of 7.5fps based upon schedule 40 pipe. • Rated Flow identifies maximum continuous duty performance determined by AWWA. • UL Flow Rate is 150% of Rated Flow and is not recommended for continuous duty. • AWWA Manual M22 [Appendix C] recommends that the maximum water velocity in services be not more than 1 Ofps. 6" (150mm) psi Service Flow Rated Flow *111, Rated Flow 18 16 14 H 12 10 8 0 300 600 900 1200 1500 gpm 0 1140 2280 3420 4560 5700 Ipm 7.5 12 fps 8 " (200mm) psi Service Flow Rated Flow Rated Flow 18 N 16 z H 14 12 10 8 6 z N H 500 gpm 0 500 1000 1500 2000 2500 gpm 1900 Ipm 0 1900 3800 5700 7600 9500 Ipm fps 7.5 10 fps 10- (250MM) *111. Rated Flow z N H 0 100 200 300 400 500 600 700 800 gpm 0 380 760 1140 1520 1900 2280 2660 3040 Ipm 7.5 13 fps 4" BFG (100 mm) Horizontal Service Flow Rated Flow *UL Rated Row 0 100 200 300 400 500 600 700 800gpm 0 380 760 1140 1520 1900 2280 2680 30401pm 7.5 13 fps VAWArM A Watts Water Technologies Company ES-957/957N/957Z 1529 psi 16 14 12 10 t 8 6 4 low z N H 0 500 1000 1500 2000 2500 3000 3500 gpm 0 1900 3800 5700 7600 9500 11400 13300 Ipm 7.5 10 fps 6" BFG (150 mm) Horizontal psi Service Flow Rated Flow TL Rated flow 16 14 9 12 0 8 6 t 4 2 0 0 200 400 600 800 1000 1200 1400 1600gpm 0 760 1520 2280 3040 3800 4560 5300 60601pm 7.5 12 fps USA: Tel: (978) 689-6066 - Fax: (978) 975-8350 - Watts.corn Canada: Tel: (905) 332-4090 - Fax: (905) 332-7068 - Watts.ca Latin America: Tel: (52) 81-1001-8600 - Fax: (52) 81-8000-7091 - Watts.corn (D 2015 Watts ANCHOR AULT �ETE SLAB ) GRADE 4'MIN CONCRETE SLAB NOT TO SCALE LA 2" AND SMALLER REDUCED PRESSURE City Of PRINCIPAL ASSEMBLY INSTALLATION SHEET: WS -21A Tukwila REVISION#1: ()2-2014 LAST REVISION: 1. THE RPPA SHALL BE INSTALLED WITH ADEQUATE SPACE TO FACILITATE MAINTENANCE AND TESTING. IT SHALL BE TESTED AFTER INSTALLATION, BY A WASHINGTON STATE CERTIFIED BACK-FLOW ASSEMBLY TESTER, TO INSURE ITS SATISFACTORY OPERATION BEFORE OCCUPANCY AND ANNUALLY THEREAFTER. A COPY OF THE TEST RESULTS SHALL BE GIVEN TO THE PUBLIC WORKS INSPECTOR. 2. AN RPPA SHALL NOT BE INSTALLED INA PIT BELOW GROUND LEVEL. 1 THE FREEZE PROTECTION ENCLOSURE FOR THE RPPA MUST INCLUDE A DAYLIGHT DRAIN. THE DRAIN MUST BE ABLE TO BE BORE SIGHTED. IT MUST BE INSTALLED ABOVE GROUND LEVEL. THE DRAIN MUST ALSO BE ABLE TO HANDLE THE VOLUME OF WATER THAT POTENTIALLY COULD BE DISCHARGED FROM THE RELIEF PORT. 4. THE FREEZE PROTECTION ENCLOSURE SHALL BE SUPPORTED BY A MIN. FOUR (4) INCH CONCRETE SLAB WITH FOUR (4) ANCHOR BOLTS ATTACHING THE COVERING TO THE SLAB. 5. RPPA MUST BE PROTECTED FOR FREEZING. 6. AN RPPA INSTALLED MORE THAN FIVE (5) FEET ABOVE FLOOR LEVEL MUST HAVE A PLATFORM UNDER IT FOR THE TESTER OR MAINTENANCE PERSON TO STAND ON. THE PLATFORM MUST BE OSHA APPROVED AND MEET ALL APPLICABLE SAFETY STANDARDS AND CODES. 7. WHEN THE RPPA IS LOCATED INSIDE A BUILDING IT SHALL BE INSTALLED INA LOCATION WHERE BOTH THE OCCASIONAL SPITTING FROM THE RELIEF PORT AND THE POSSIBLE CONSTANT DISCHARGE DURING A FOULED CHECK VALVE SITUATION WILL NOT BE OBJECTIONABLE. AN APPROVED AIR GAP FUNNEL ASSEMBLY, EITHER PROVIDED BY THE MANUFACTURER OF FABRICATED FOR SPECIFIC INSTALLATION, MAY BE INSTALLED TO HANDLE THE OCCASIONAL SPITTING OF THE RELIEF VALVE DUE TO PRESSURE FLUCTUATIONS. A LINE FROM THIS FUNNEL ASSEMBLY MAY THEN BE RUN TO AN ADEQUATELY SIZED FLOOR DRAIN OF EQUAL OR GREATER SIZE. IT MUST BE EMPHASIZED THAT THE AIR GAP FUNNEL ASSEMBLY WILL HANDLE ONLY THE OCCASIONAL SPITTING AND WILL NOT CONTROL FLOW IN A CONTINUOUS RELIEF SITUATION. 8. A PVC COLLAR SHALL BE INSTALLED BETWEEN THE PIPE AND CONCRETE SLAB. 9. A UNION SHALL BE INSTALLED ON THE RISERS TO AID IN REMOVAL OF THE ASSEMBLY. 10. BALL VALVES WILL BE INSTALLED ON THE RISERS TO AID IN THE TESTING AND MAINTENACE OF THE ASSEMBLY. 11. ALL BRASS FITTINGS SHALL BE LEAD FREE. NOT TO SCALE 2" AND SMALLER REDUCED PRESSURE City Of PRINCIPAL ASSEMBLY INSTALLATION 43 SHEET: WS -21B A REVIS ION #1: 02-2014 LAST REVISION: Tukwila I APPROVAL: R TIRr.HMAK r-ITY FNr.INEFR City of Tukwila Department of Community Development November 15, 2016 JULIE GLENN 1326 FIFTH AVE SUITE 400 SEATTLE, WA 98 101 RE: Correction Letter # 2 DEVELOPMENT Permit Application Number D16-0260 WESTERN FOODS - 641 INDUSTRY DR Dear JULIE GLENN, Allan Ekberg, Mayor Jack Pace, Director This letter is to inform you of corrections that must be addressed before your development permit can be approved. All correction requests from each department must be addressed at the same time and reflected on your drawings. I have enclosed comments from the following departments: PW DEPARTMENT: Joanna Spencer at 206-431-2440 if you have questions regarding these comments. 1) None of the two PW comments spelled out in October 11, 2016 correction letter #1 were addressed in your response submittal. a) Applicant mentioned in an email that Non -Residential Sewer Use Certification will be submitted by the owner, however as of today this form was not received; b) A Reduced Pressure Principle Assembly (RPPA) shall be installed on domestic water service. Please submit plans as a revision to this permit or a bond or as a separate Public Works Type C construction permit. Please address the comments above in an itemized format with applicable revised plans, specifications, and/or other documentation. The City requires that two (2) sets of revised plan pages, specifications and/or other documentation be resubmitted with the appropriate revision block. In order to better expedite your resubmittal, a'Revision Submittal Sheet'must accompany every resubmittal. I have enclosed one for your convenience. Correctionshevisions must be made in person and will not be accepted through the mail or by a messenger service. If you have any questions, I can be reached at 206-431-3655. Sincerely, Bill Rambo Permit Technician File No. D16-0260 6300 Southcenter Boulevard Suite #100 e Tukwila Washington 98188 9 Phone 206-431-3670 e Fax 206-431-3665 BURGESS INTERIOR ARCHITECTURE October 21, 2016 Bill Rambo Permit Technician Department of Community Development Tukwila, WA Project Number: D16-0260 Dear Mr. Rambo, CORRE(YION LTRO_ In response to your letter dated October 1 1th, 2016 we are providing the following information. Below please find the text of your comments followed by our response in italics. Building Department Correction Notice # 1: 1. (GENERAL NOTE) PLAN SUBMITTALS: (Min. size 11x17 to maximum size of 24x36; all sheets shall be the same size. New revised plan sheets shall be the same size sheets as those previously submitted.) (If applicable) "STAMP AND SIGNATURES" "Every page of a plan set must contain the seal/stamp, signature of the licensee(s) who prepared or who had direct supervision over the preparation of the work, and date of signature. Specifications that are prepared by or under the direct supervision of a licensee shall contain the seal/stamp, signature of the licensee and the date of signature. If the "specifications" prepared by a licensee are a portion of a bound specification document that contains specifications other than that of an engineering or land surveying nature, the licensee need only seal/stamp that portion or portions of the documents for which the licensee is responsible." It shall not be required to have each page of "specifications" (calculations) to be stamped and signed; Front page only will be sufficient. (WAC 196-23-010 & 196-23-020) RECEIVED Response: We have provided the Architects stamp at each 24x36 sheet. CITY OF TUKWILA Sheets: ALL SHEETS, see entire set of documents. OCT 24 2016 (Please see our clouded response shown as Delta 1 Correction dated 10. 21.16.) PERMIT CENTER 2. (BUILDING REVIEW NOTES) In addition to the egress plan provided, show specific, common paths of egress where emergency illumination shall be provided an average I foot-candle and a minimum at any point of 0.1 -foot candle measured along the path of egress at the floor level. Emergency lighting shall also be required at exterior landings or exit discharge doorways where two or more exits are required. Egress paths shall be continuous, unobstructed, unbroken paths to each exit. Designated egress paths are those that shall be light meter inspected for egress illumination requirements (IBC 1,,07.2.3 & Section 1006). P 206 1 587 1 7120 F 206 1 587 1 7122 1326 FIFTH AVENUE, SUITE 4M SEATTLE, WASHINGTON 98101 info@Bur§-essPNW.com www.BurgessPNW.com BURGESS INTERIOR ARCHITECTURE Response: The path of egress, emergency lighting is shown on the Egress Plan, G. 0. 2. The updated emergency lighting fixtures have been added/updated on the Reflected ceiling plan, based on said egress path. Sheets: G. 0. 2 & A. 2B. 2. (Please see our clouded response shown as Delta 1 Correction dated 10. 21.16.) 3. The energy code lighting forms provided are no longer valid. Provide a completed 2015 Washington State Energy Code "LIGHTING SUMMARY" Compliance Forms for Commercial Buildings available online at: http://www.neec.net/energy-codes (scroll down to center of page "2015 WSEC Commercial Provisions - Compliance Forms"). Response: The lighting summary has been updated to the 2015 version. Sheets: A. 2B. 2, Reflected Ceiling Plan, Lighting Summary. (Please see our clouded response shown as Delta 1 Correction dated 10.21.16.) 4. The plumbing fixture matrix table is somewhat confusing in the calculations shown as I cannot trace for verification to the plumbing tables of Chapter 29 IBC. Please provide some clarification as to how the numbers are achieved in accordance with IBC Chapter 29 with the Washington State Amendments (WSA). (I BC [P] 2902. 1, [P] TABLE 2902.1 & WSA 2902.5.1) Response: The Plumbing matrix has been updated with more information from IBC 2015, 2902. 1 & 2902.5. 1. Helping to breakdown the calculations for water closets, lavatories and drinking fountains. Sheets: G.0.2, Plumbing Fixtures Matrix. (Please see our clouded response shown as Delta 1 Correction dated 10. 21.16.) 5. PLANNING DEPARTMENT., MAX BAKER at (206)-431-3683 if you have questions regarding these comments. Need more information to determine use type of site, i.e. what activities will be taking place within. Must comply with zoning requirements of district, Tukwila Urban Center - Work Place. Response: Western Foods is a National Corporate Food Service Sales Agency, Distribution and Training Center. Including demonstrations and creating marketing strategies for non- perishable foods and goods. Sheets: G. 0. 0, Building Summary. (Please see our clouded response shown as Delta I Correction dated 10. 21.16.) P 206 1 587 1 7120 1326 FIFTH AVENUE, SUITE 400 info@ BurgessPNW. corn IF 206 1 587 1 7122 SEATTLE, WASHINGTON 98101 www.BurgessPNW.com LB I BURGESS INTERIOR ARCHITECTURE 6. PW DEPARTMENT: Joanna Spencer at 206-431-2440 if you have questions regarding these comments. 1) Please fill out the attached Non -Residential Sewer Use Certification form and list all new plumbing fixtures to be installed. Do not list fixtures to be replaced in kind. 2) Since the plumbing system is going to be modified, cross -connection control measures need to be implemented. A Reduced Pressure Principle Assembly (RPPA) shall be installed immediately downstream of the existing 1.5" permanent water meter. Installation at another location requires the Public Works Director's approval. The RPPA shall be installed in a Hot Box/Hot Rock or equal freeze protection enclosure anchored to a minimum 4" thick concrete pad. A separate letter addressing this issue was mailed to Skanlan Kemper Bard and NCWP Andover Executive Park, property owner. Response: Skanlan Kemper Bard is responding to Non -Residential Sewer Use Certification Form separately. Thank you very much. Sincerely, Julie Glenn Burgess Design P 206 1 587 1 7120 1326 FIFTH AVENUE, SUITE 400 info@BurgessPNW.com IF 206 1 587 1 7122 SEATTLE, WASHINGTON 98101 www.BurgessPNW.com City of Tukwila Allan Ekberg, Mayor Department of Community Development Jack Pace, Director October 11, 2016 JULIE GLENN 1326 FIFTH AVE SUITE 400 SEATTLE, WA 98 101 RE: Correction Letter # I DEVELOPMENT Permit Application Number D16-0260 WESTERN FOODS - 641 INDUSTRY DR Dear JULIE GLENN, This letter is to inform you of corrections that must be addressed before your development permit can be approved. All correction requests from each department must be addressed at the same time and reflected on your drawings. I have enclosed comments from the following departments: BUILDING DEPARTMENT: Allen Johannessen at 206-433-7163 if you have questions regarding these comments. (GENERAL NOTE) PLAN SUBMITTALS: (Min. size I I x] 7 to maximum size of 2406; all sheets shall be the same size. New revised plan sheets shall be the same size sheets as those previously submitted.) (If applicable) "STAMP AND SIGNATURES" "Every page of a plan set must7contain the seal/stamp, signature of the licensee(s) who prepared or who had direct supervision over the preparation of the work, and date of signature. Specifications that are prepared by or under the direct supervision of a licensee shall contain the seal/stamp, signature of the licensee and the date of signature. If the "specifications" prepared by a licensee are a portion of a bound specification document that contains specifications other than that of an engineering or land surveying nature, the licensee need only seal/stamp that portion or portions of the documents for which the licensee is responsible." It shall not be required to have each page of "specifications" (calculations) to be stamped and signed; Front page only will be sufficient. (WAC 196-23-010 & 196-23-020) (BUILDING REVIEW NOTES) 1. In addition to the egress plan provided, show specific, common paths of egress where emergency illumination shall be provided an average I foot-candle and a minimum at any point of 0. 1 -foot candle measured along the path of egress at the floor level. Emergency lighting shall also be required at exterior landings or exit discharge doorways where two or more exits are required. Egress paths shall be continuous, unobstructed, unbroken paths to each exit. Designated egress paths are those that shall be light meter inspected for egress illumination requirements. (IBC 107.2.3 & Section 1006) 2. The energy code lighting forms provided are no longer valid. Provide a completed 2015 Washington State Energy Code "LIGHTING SUMMARY" Compliance Forms for Commercial Buildings available online at: http://www.neec.neUenergy-codes (scroll down to center of page "2015 WSEC Commercial Provisions - Compliance Forms"). 3. The plumbing fixture matrix table is somewhat confusing in the calculations shown as I cannot trace for verification to the plumbing tables of Chapter 29 IBC. Please provide some clarification as to how the numbers are achieved in accordance with IBC Chapter 29 with the Washington State Amendments (WSA). (IBC [P] 2902. 1, [P] TABLE 2902.1 & WSA 2902.5. 1) Note: This permit plan review may not be complete as revised plans may require further corrections. 6300 Southcenter Boulevard Suite #100 e Tukwila Washington 98188 * Phone 206-431-3670 0 Fax 206-431-3665 PLANNING DEPARTMENT: Nj,,AX BAKER at (206)-431-3683 if you have questions regarding these comments. 0 Need more information to determine use type of site, i.e. what activities will be taking place within. Must comply with zoning requirements of district, Tukwila Urban Center - Work Place. PW DEPARTMENT: Joanna Spencer at 206-431-2440 if you have questions regarding these comments. 1) Please fill out the attached Non -Residential Sewer Use Certification form and list all new plumbing fixtures to be installed. Do not list fixtures to be replaced in kind. 2) Since the plumbing system is going to be modified, cross -connection control measures need to be implemented. A Reduced Pressure Principle Assembly (RPPA) shall be installed immediately downstream of the existing 1.5" permanent water meter. Installation at another location requires the Public Works Director's approval. The RPPA shall be installed in a Hot Box/Hot Rock or equal freeze protection enclosure anchored to a minimum 4" thick concrete pad, A separate letter addressing this issue was mailed to Skanlan Kemper Bard and NCWP Andover Executive Park, property owner. Please address the comments above in an itemized format with applicable revised plans, specifications, and/or other documentation. The City requires that two (2) sets of revised plan pages, specifications and/or other documentation be resubmitted with the appropriate revision block. In order to better expedite your resubmittal, a'Revision Submittal Sheet'must accompany every resubmittal. I have enclosed one for your convenience. Corrections/revisions must be made in person and will not be accepted through the mail or by a messenger service. If you have any questions, I can be reached at 206-431-3655. Sincerely, Bill Rambo Permit Technician File No. D 16-0260 6300 Southcenter Boulevard Suite #100 9 Tukwila Washington 98188 e Phone 206-431-3670 9 Fax 206-431-3665 C 0 ity of Tukwila Allan Ekberg, Mayor Public Works Department - Bob Giberson, Director September 28, 2016 NCWP Andover Executive Park419999 810 NW Marshalls St #300 Portland, OR 97209 RE: Western Foods Tenant Improvement 641 Industry Drive, Tukwila WA Permit Number: D16-0260 To Whom It May Concern: In accordance with Washington State Department of Health guidelines for Group A Public Water Systems, Public Works has implemented a cross -connection control program to protect the public water system from contamination via cross -connection. The program requires elimination or control of any cross -connection between the distribution system and a consumer's water system by the installation of an approved backf[ow device. The City has determined that the building at the above address has deficiencies on the domestic water service. A Reduced Pressure Principle Assembly (RPPA), previously called a Reduced Pressure Backflow Assembly (RPBA), shall be installed immediately downstream of the existing I 1/2 -inch permanent water meter. Installation at another location requires the Public Works Director's approval. The RPPA shall be installed in a Hot Box/Hot Rock or equal freeze protection enclosure anchored to a minimum 4" thick concrete pad. On your site plan, please show the property line(s), street name, North arrow, building location, existing permanent water meter and proposed RPPA. Specify size, manufacturer name and backflow model number. Submit RPPA cut sheet and circle the backflow to be installed. If you opt to install now, you wilt need to apply for a Public Works Type C Construction Permit and submit the permit application with (4) four sets of plans together with a construction cost estimate for the RPPA installation. For a Type C permit, Public Works collects a base application and plan review fee ($250.00 plus 2.5% of the construction cost for installation of the subject device) when the application or revision to this Tenant Improvement is submitted. An additional 2.5% of the construction cost for backf[ow installation will be assessed at the time of permit issuance. 630OBuilding # 6300 Southcen ter Boulevard Suite 100 # Tukwila, WA98188 * 206-433-0179 Tukwila City Hoff - 6200 Southcenter Boulevard - Tukwila, WA 98188 - 206-433-1800 - Website: TukwilaWA.gov DIG- 02GO ' ` NCWP Andover Executive Park419999 September 28, 2016 Page 2 If you opt to bond for the installation, you must provide the following to the Permit Center: 1) an original design and installation estimate, 2) a bond for 150% of the design and installation cost, and 3) a letter stating your intent to install the backf[ow within 90 days. The Public Works Director will withhold issuance of the subject Tenant Improvement permit until the backflow permit application is received or bond is posted. I have enclosed Public Works Bulletins A1-2, and C5 to help you. If you have any questions, please call Mr. Mike Cusick, P.E., Public Works Senior Water and Sewer Engineer, at (206) 431-2441 or me at (206) 431-2440 orjoanna.spencer@tukwilawa.gov. Sincerely, Clef Joanna Spencer Development Engineer JSAW enclosures: Public Works Bulletins #A1-2, and C5 Permit Application cc: D16-0260 File Julie Glen Skanlan Kemper Bard (W:PW Eng/Other/Joanna Spencer/Letter NCWP Andover Executive Park 092816) J David McPherson From: Todd Reedy Sent: Tuesday, September 27, 2016 1:06 PM To: David McPherson Subject: RE: backflow for Western Foods at 641 Industry Drive — Tennant Improvement — D16-0260 Hello David, Regarding backflow protection at 641 Industry Drive: -No RPPA installed on 1.5" domestic service. -No irrigation or fireline connection at this location. Let me know if you have any questions, Todd From: David McPherson Sent: Tuesday, September 27, 2016 9:40 AM To: Todd Reedy <Todd. Reedy @Tu kwi laWA.gov> Cc: Joanna Spencer <Joanna.Spencer@TukwilaWA.gov> Subject: backflow for Western Foods at 641 Industry Drive — Tennant Improvement — D16-0260 Todd, Please let me know, if backflow is current for Western Foods at 641 Industry Drive — Tennant Improvement — D16-0260. TIL no. 252304-9008. Thank you. Dave PERMIT COORD COPY. PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: D16-0260 PROJECT NAME: WESTERN FOODS SITE ADDRESS: 641 INDUSTRY DR Original Plan Submittal DATE: 11/17/16 Revision # before Permit Issued X Response to Correction Letter # 2 Revision # after Permit Issued Building Division F] �� PW(" Public Works PRELIMINARY R&IEW: Not Applicable 1-1 (no approvallreview required) REVIEWER'S INITIALS: APPROVALS OR CORRECTIONS: Approved 11 Corrections Required F-1 (corrections entered in Reviews) Notation: REVIEWER'S INITIALS: Fire Prevention F-1 Structural 1:1 Planning Division 1:1 Permit Coordinator of DATE: 11/22/16 Structural Review Required E] DATE: DUE DATE: 12/20/16 Approved with Conditions F-1 Denied F-1 (ie: Zoning Issues) DATE: Perinit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: BldgEj FireE] PlngE] PWE] Staff Initials: 12/18/2013 e; PERMIT COORD COPT PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: D16-0260 PROJECT NAME: WESTERN FOODS SITE ADDRESS: 641 INDUSTRY DR Original Plan Submittal X Response to Correction Letter # I DATE: 10/24/16 Revision # Revision # before Permit Issued after Permit Issued DEPARTMENTS: 111a tv C t (44 Building tvision -w coff !� Public Works Fire Prevention Planning Division Structural Permit Coordinator PRELIMINARY REVIEW: DATE: 10/25/16 Not Applicable 1-1 Structural Review Required El (no approvallreview required) REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: DUE DATE: 11/22/16 Approved E] Approved with Conditions F] Corrections Required Nr Denied F-1 (corrections entered in Reviews) (ie: Zoning Issues) ki–� &W Notation: 5, REVIEWER'S INITIALS: DATE: Perinit Center Use Only CORRECTION LETTER MAILED: V4 Departments issued corrections: Bldg [I rire F1 Plng F1 PWW Staff Initials: 12/18/2013 PERMIT COORD COPY PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: D16-0260 DATE: 09/26/16 PROJECT NAME: WESTERN FOODS SITE ADDRESS: 641 INDUSTRY DR X I Original Plan Submittal Response to Correction Letter #, DEPARTMENTS: COWP- q-)g-t� Building Division ,�� CLwry Public Works , PRELIMINARY REVIEW: Not Applicable El (no approvallreview required) REVIEWER'S INITIALS: Revision # before Permit Issued Revision # after Permit Issued A-0 Awc 10-)-H� �Ale> Fire Prevention V Planning Division Structural F Permit Coordinator 1:1 DATE: 09/27/16 Structural Review Required DATE: APPROVALS OR CORRECTIONS: DUE DATE: 10/25/16 Approved Approved with Conditions El Corrections Required rsQl-*, I IrL (corrections entered in ReviewsT--�l Notation: REVIEWER'S INITIALS: Denied El (ie: Zoning Issues) DATE: Permit Center Use Only CORRECTION LETTER MAILED: n Departments issued corrections: Bldg Fire El Plng J�r— PVQr Staff Initials: 07 12/18/2013 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Web site: h!Ltp://www.TukwilaWA.gov REVISION SUBMITTAL Revision submittals must be submitted in person at tile Permit Center. Revisions will not be accepted through the mail, fax, etc. Date: �t I IGIZO(o Plan Check/Permit Number:- [)-I G - 02GO F� Response to Incomplete Letter 4 IV/ Response to Correction Letter F� Revision after Permit is Issued F-1 Revision requested by a City Building Inspector or Plans Examiner n Deferred Submittal # Project Name: NA c4ev- vi Fooci6 Project Address: WL -t I ContactPerson: �OAONW Summary of Revision: �Z�e– 64�"Vk L) p - -;7 06 Phone Number: I QC) RECEIV-E]Y- CITY OF TUMILA NOV 1 T-2016 Sheet Number(s): "Cloud" or highlight all areas of revision includin*.-Ia%o�revision Received at the City of Tukwila Permit Center by: - 6W tj�— Entered in TRAKiT on I I '( -0 W Termit CenteATemplatesTorms\Revision Submittal Form,doc Revised: August 2015 kLA, City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206-431-3665 Web site: http://�ww.ci.tukwila.wa.us REVISION SUBMITTAL Revision submittals must be submitted in person at the Permit Center. Revisions ivill not be accepted through th e mail, fax, etc. Date: Plan Check/Permit Number: F-1 Response to incomplete Letter # Z Response to Correction Letter 4 1 F-� Revision # after Permit is Issued F-1 Revision requested by a City Building Inspector or Plans Examiner Project Name: Western Foods Project Address: 641 Industry Dr Contact Person: JAQ, Rem —PhoneNumber: Summary of Revision: D 16-0260 V- T M KI I RIECEIVED SheetNumber(s): rJ-0-11 A-22.2/ CITY OF TUKWILA OCT 2 4 2016 "Cloud" or highlight all areas of revision including date of revision Received at the City of Tukwila Permit Center by: �Me PERMIT CENTER Entered in TRAKiT on 0 \applications\forms-applications on line\revision submittal Created: 8-13-2004 Revised: Lg King County Department of Natural Resources a " d Parks Wastewater Treatment Division Non -Residential Sewer Use Certification • To be completed for all new sewer connections, reconnections or change of use of existing connections. • This form does not apply to repairs or replacements of existing sewer connections within five years of disconnect. Please Print or Type - Property Street Address City State ZIP Owner's Name Subdivision Name Lot Subdiv. # Block # Building Name (if applicable) (602 377-6363 's Phone Number (with Area Code) (206 ) 575-0765 Property Contact Phone Number (with Area Code) Owner's Mailing Address A. Fixture Units Fixture Units x Number of Fixtures Total Fixture Units Kind of Fixture Fixture Units No. ol Fixtures — Total Public Pfivate Public Private Fixture units Bathtub and Shower _�h_ower, 4 4 per head 2 2 Dishwasher 2 2 Drinking f6untain (each head) 1 .5 Hose bibb (interior) 2.5-- 2�5 Clotheswasher or laundry tub 4 2 Sink, bar or lavatory 2 1 7 Sink, Clinic flushing 8 8 Sink, kitchen 3 2 Sink, other (service) 3 1.5 Sink, wash fountain, circle spray 4 3 Urinal, flush valve, 1 GPF 5 2 Urinal, flush valve, >1 GPF 6 2 l. Frinai, waterless 0 __ 0 Water closet, lank or valve, 1.6 GPF 16— 3 Water closet, tank or valve, >11.6 GPF 8 4 Total Fixture Units Residential Customer Equivalent (RCE) 20 fixture units equal 1.0 RCE Total No. of Fixture Units RCE 20 For King County Use Only Account# No. of RCEs Monthly Rate Property Tax ID 4$ Party to be Billed (if different from owner) City or Sewer District Date of Connection Side Sewer Permit # Please report any demolitions of pre-existing building on this property, Credit for a demolition may be given under some circumstances. Demolition of pre-existing building? ElYes ZINO Was building on Sanitary Sewer? DYes NWo Was Sewer connected before 2/11/90? WYes ONO Sewer disconnect date: Type of building demolished? Request to apply demolition credit to multiple buildings? DYes ONO B. OtherWastewater Flow (in addition to Fixture Units identified in Section A) 1A _1 , Type of Facility/Process: E C T11 0 IN Estimated Wastewater Discharge: Gallons/clays Residential Customer Equivalents (RCE): 187 gallons per day equals 1.0 RCE Total Discharge (gal/day) RCE 187 C. Total Residential Customer Equivalents: (add A & B) A B RCE RECEIVED CITY OF TUKWILA NOV 17 2016 PERMIT CENTER Pursuant to King County Code 28.84, all sewer customers who establish a new service which uses metropolitan sewage facilities shall be subject to a capacity charge. The amount of the charge is established annually by the King County Council at a rate per month per residential customer or residential customer equivalent for a period of fifteen years. The purpose of the charge is to recover costs of providing sewage treatment capacity for new sewer customers. All future billings can be prepaid at a discounted amount. All future billings can be prepaid at a discounted amount. Questions regarding the capacity charge or this form should be referred to King County's Wastewater Treatment Division at 206-684-1740. 1 certify that the information given is correct. I understand that the capacity charge levied will be based on this information and any deviation will require resubmission of corrected data for determination of a revised capacity charge. Signature of Owner/Representative Date Print Name of Owner/Representative 1058 (Rev 9/07) While — Who Countv Yellow — Local Sewer Aoe�cv Pink — Sewer Customer .,Egg-. (r�� D P INC GENERAL CCINTRACTCI`� H OTn e. Rspafiol Contact Safety & Health Claims & Insurance inWashington State Department of Labor & Industries Page I of 2 ISearch L&I A --Z Index Help My LIZ:[ Workplace Rights Trades & Licensing I D P INC GENERAL CONTRACTORS I Owner or tradesperson Principals DODSON, WILLIAM, PRESIDENT Doing business as D P INC GENERAL CONTRACTORS WA UBI No� 601515833 19936 BALLINGER WAY NE SEATTLE, WA 98155 206-361-2989 KING County Business type Corporation ILicense I Verify the contractor's active registration / license / certification (depending on trade) and any past violations. Construction Con–Irac.to.r. Active. Meets current requirements. License specialties $1,000,000.00 GENERAL License no. DPINCGCO66BU Effective date Effective — expiration 09/1512016 01 /31/1994— 01/31/2018 Expiration date Bond 09/15/2017 Merchants Bonding Co (Mutual) $12,000.00 Bond account no. WA28622 Received by L&I Effective date 12/27/2012 01131/2013 Expiration date Until Canceled Bond history Insurance Continental Western Ins Co $1,000,000.00 Policy 110. CPA6015605 Received by L&I Effective date 08/0412016 09/1512016 Expiration date 09/15/2017 Insurance history Savin No savings accounts during the previous 6 year period. Lawsuits p�gainst the bond or savings No laws' uits a,ga in s"t t'he", b'o'*n'd*' o r"s'a"v-i'n'gs accounts during the previous 6 year period. L&I Tax debts No"I'Miax- debts are recorded for this contractor license during the previous 6 year period, but some delr'ts may be recorded by other agencies. Help us improve https:Hsecure.Ini.wa.gov/verify/Detail.aspx?UB1=601515833&LIC=DPINCGCO66BU&SAW= 12/19/2016 D P INC GENERAL CONTRACTORS Page 2 of 2 License Violations N6"iic"'e'n's''e"'v"i"o*'I"at'io'ns during the previous 6 y_ period. IWorkerscomp Do you know if the business has employees? If so, verify the business is up-to-date on workers'comp premiums. L&I Account ID Account is current. 578,236-01 Doing business as DPINC Estimated workers reported Quarter 3 of Year 2016 "Greater than 100 Workers" L&I account representative T2 I HAN CHUNG (360)902-4713 - Email: CHUK235@lni.wa.gov Workplace safety and health Check for any past safety and health violations found on jobsites this business was responsible for. Inspection results date 03/05/2014 Violations Inspection no. 316958065 Location 625 Andover Park W. Tukwila, WA 98188 0,; Washington State Dept, of Labor & Industries. Use of this site is subject to the laws of the state of Washington. Help us improve https:Hsecure.Ini.wa.gov/verify/Detail.aspx?UBI=601515833&LIC=DPINCGCO66BU&SAW= 12/19/2016 GENERAL NOTES 1. CONTRACTOR SHALL COMPLY WITH THE CURRENT "GENERAL CONDITIONS," AND BUILDING STANDARDS AS PROVIDED BY THE BUILDING OWNER. 2. GENERAL CONTRACTOR S HALL BE RESPONSIBLE FOR COORDINATING THE WORK OF DIFFERENT TRADES. 3. DO NOT SCALE DRAWINGS. CONTACT ARCHITECT FOR ANY MISSING DIMENSIONS. 4. CONTRACTOR INITIATED CHANGES SHALL BE SUBMITTED IN WRITING TO THE OWNER AND ARCHITECT FOR APPROVAL PRIOR TO FABRICATION OR CONSTRUCTION. CHANGES SHOWN ON SHOP DRAWING ONLY WILL NOT SATISFY THIS REQUIREMENT. 5. ALL MODIFICATIONS, REQUIRING OWNER OR ARCHITECT APPROVAL WILL NOT BE VALID UNLESS AUTHORIZED IN WRITING BY OWNER AND/OR ARCHITECT. 6. WITHIN FIVE (5) BUSINESS DAYS OF START OF CONSTRUCTION, THE CONTRACTOR SHALL NOTIFY IN WRITING BOTH THE ARCHITECT AND OWNER OF ANY ITEMS WHOSE ESTIMATED DELIVERY TO THE SITE WOULD BE LATER THAN THAT REQUIRED FOR TIMELY INSTALLATION IN THE CONSTRUCTION SEQUENCE SUBSTITUTION OF ALTERNATE ITEMS WITH SHORTER LEAD TIMES, PAYMENT OF RUSH FABRICATION OR DELIVERY CHARGES OUT OF SEQUENCE INSTALLATION, OR DELAY OF INSTALLATION OPTIONS TO BE AT THE SOLE APPROVAL OF OWNER OR ARCHITECT. 7. CONTRACTOR SHALL BE RESPONSIBLE FOR PROVIDING ALL WORK AND MATERIALS IN ACCORDANCE WITH THE LATEST LOCAL BUILDING CODES AND ORDINANCES. 8. CONTRACTOR SHALL VERIFY ALL FIELD DIMENSIONS AND CONDITIONS AND SHALL REPORT ANY CONFLICTS OR QUESTIONS FOR RESOLUTION BEFORE PROCEEDING WITH THE WORK. DO NOT SCALE THE DRAWINGS. 9. THE USE OF WORD "PROVIDE" SHALL ALWAYS MEAN, "FURNISH AND INSTALL, CONNECT, OR SECURE" AS REQUIRED. 10. ALL MATERIALS AND EQUIPMENT SHALL BE INSTALLED IN STRICT ACCORDANCE WITH MANUFACTURERS WRITTEN INSTRUCTIONS AND TRADE ASSOCIATES ACCEPTED STANDARDS. 11. CONTRACTOR SHALL PROVIDE A WRITTEN CONSTRUCTION SCHEDULE. THIS SCHEDULE SHALL INCLUDE DELIVERY LEAD TIMES OF CONSTRUCTION ITEMS, AND START AND COMPLETION DATES OF EACH PHASE. THE CONTRACTOR SHALL UPDATE AND PROVIDE SUCH SCHEDULE ON A BIWEEKLY BASIS. 12. WORK MUST BE SCHEDULED WITH THE BUILDING MANAGEMENT TO AVOID DISRUPTION TO THE TENANTS. 13. ACCESS TO AND FROM THE PROJECT SITE, SPECIAL CONDITIONS, NOISY WORK, TIMING OF WORK, INTERRUPTION OF MECHANICAL AND ELECTRICAL SERVICES, RELOCATION OF EXISTING EQUIPMENT, CASEWORK, FIXTURES, FITTINGS, ETC., MUST BE COORDINATED WITH THE BUILDING MANAGEMENT. 14. ADEQUATE CLEANUP, PROTECTION AND PLACEMENT OF ANY CEILING TILES AND/OR OTHER DISRUPTION TO THE ADJACENT TENANT IMPROVEMENTS MUST BE REPLACED BEFORE BUSINESS HOURS OF THAT TENANT IN ORDER THAT THE OCCUPANT WILL NOT BE INCONVENIENCED IN THE NORMAL CONTINUATION OF THEIR OFFICE HOURS. 15. EACH SUBCONTRACTOR IS RESPONSIBLE FOR ANY DAMAGE TO ADJACENT WORK AND SHALL REPAIR SAID DAMAGE AT THEIR OWN EXPENSE. THIS INCLUDES ALL AREAS ON THE PREMISES SUCH AS: COMMON HALLWAYS, FREIGHT ELEVATOR VESTIBULES, ETC. 16. SCHEDULE THE USE OF THE ELEVATOR WITH BUILDING MANAGEMENT. 17. UPON COMPLETION OF ALL CONSTRUCTION, THE CONTRACTOR SHALL SUPPLY THE LANDLORD WITH ONE SET OF "RECORD" AS -BUILT DRAWINGS. 18. ALL MATERIALS TO BE NEW LION. 19. PATCH ALL DISTURBED AND/OR DAMAGED AREAS AS REQUIRED TO ACCOMPLISH NEW WORK AND AS REQUIRED FOR FINISHED APPEARANCE. 20. GENERAL CONTRACTOR IS RESPONSIBLE FOR PROVIDING ALL NECESSARY BACKING, BLOCKING, AND FRAMING FOR LIGHT FIXTURES, ELECTRICAL FIXTURES, CASEWORK AND ALL OTHER ITEMS REQUIRING IT. 21. CONTRACTOR TO COORDINATE ALL FIRE ALARM WORK WITH BUILDING OWNER. 22. ALL PAINT AND FINISH MATERIAL COLORS SHALL MATCH. ARCHITECT'S CONTROL SAMPLES AND REQUIRE ARCHITECT'S REVIEW PRIOR TO INSTALLATION. SUBMIT TO ARCHITECT THREE (3) COPIES FOR REVIEW. 23. CONTRACTOR SHALL FURNISH SHOP DRAWINGS FOR REVIEW ON CABINETWORK, MILLWORK AND ANY OTHER SPECIAL ITEMS REQUIRING CUSTOM SHOP FABRICATION. SUBMIT TO ARCHITECT AT LEAST THREE (3) COPIES FOR REVIEW. 24. REPETITIVE FEATURES NOT FULLY SHOWN OR NOTED ON THE DRAWINGS SHALL BE COMPLETELY PROVIDED AS IF DRAWN IN FULL. 25. THROUGHOUT THE DRAWINGS ARE ABBREVIATIONS WHICH ARE IN COMMON USE. THE LIST OF ABBREVIATIONS PROVIDED IS NOT INTENDED TO BE A COMPLETE LIST. THE ARCHITECT WILL DEFINE THE INTENT OF ANY IN QUESTION. ARCH / INTERIOR ADJ - ADJUSTABLE AFF - ABOVE FINISH FLOOR ALT - ALTERNATE ALUM - ALUMINUM APC - ACOUSTICAL PANEL CEILING APPROX - APPROXIMATE ARCH - ARCHITECTURAL ACT - ACOUSTICAL CEILING TILE AV - AUDIO VISUAL BLDG - BUILDING BOT - BOTTOM CAB - CABINET CL - CENTER LINE CLG - CEILING CLR - CLEAR COL - COLUMN CONIC - CONCRETE CONF - CONFERENCE DEMO - DEMOLITION DEPT - DEPARTMENT DF - DRINKING FOUNTAIN DIA - DIAMETER DIFF - DIFFUSER DIM - DIMENSION DTL - DETAIL DW - DISHWASHER DWG - DRAWING EA - EACH EL - ELEVATOR ELEC - ELECTRICAL ELEV - ELEVATION EQ - EQUAL EQUIP - EQUIPMENT EXT - EXTERIOR FA - FIRE ALARM FD - FLOOR DRAIN FE - FIRE EXTINGUISHER FEC - FIRE EXTINGUISHER CABINET FFE - FINISH FLOOR ELEVATION FIN - FINISH FLUOR - FLUORESCENT FLR - FLOOR FO - FACE OF FOIC - FURNISHED BY OWNER, INSTALLED STRUCTURAL BY CONTRACTOR FTIC - FURNISHED BY TENANT, INSTALLED SYMMETRICAL BY CONTRACTOR FURR - FURRING GA - GAUGE GC - GENERAL CONTRACTOR CL - GLASS GWB - GYPSUM WALLBOARD HC - HANDICAPPED HDW - HARDWARE HM - HOLLOW METAL (STEEL FRAME) HR - HOUR INCL - INCLUDED OR INCLUDING INFO - INFORMATION INSUL - INSULATION LAV - LAVATORY LF - LINEAR FOOT MATL - MATERIAL MAX - MAXIMUM MDF - MEDIUM DENSITY FIBERBOARD a _r 01 Oki XVA I ivffe I k WR MECH - MECHANICAL MEZZ - MEZZANINE MFR - MANUFACTURER MIN - MINIMUM MISC - MISCELLANEOUS MTD - MOUNTED MTL - METAL N/A - NOT APPLICABLE NIC - NOT IN CONTRACT NTS - NOT TO SCALE OC - ON CENTER OFF - OFFICE OPNG - OPENING OVHD - OVERHEAD P - PAINT PART - PARTITION PERF - PERFORATED PERIM - PERIMETER PERP - PERPENDICULAR PLAM - PLASTIC LAMINATE PLYWD - PLYWOOD QTY - QUANTITY (R) - RELOCATED RA - RETURN AIR RCP - REFLECTED CEILING PLAN REC - RECESSED REF - REFERENCE REFIR - REFRIGERATOR REL - RELOCATE REV - REVISION OR REVISED RM - ROOM RO - ROUGH OPENING RTD - RATED SCHEID - SCHEDULE SF - SQUARE FEET/FOOT SHT - SHEET Sim - SIMILAR SPEC - SPECIFICATION SPKLR SPRINKLER SPKR SPEAKER SQ SQUARE STD STANDARD STL STEEL STOR STORAGE STRL STRUCTURAL STRUC STRUCTURAL SYMM SYMMETRICAL TBD - TO BE DETERMINED TEL - TELEPHONE OR TELECOM TEMP - TEMPERED THK - THICKNESS TO - TOP OF TOS - TOP OF SLAB TYP - TYPICAL UON - UNLESS OTHERWISE NOTED UPS - UNINTERRUPTED POWER SUPPLY VCT - VINYL COMPOSITION TILE VIF - VERIFY IN FIELD W/ - WITH WC - WATER CLOSET WD - WOOD W/O - WITHOUT BUILDING SUMMARY 1. PROJECT ADDRESS: WESTERN FOODS ANDOVER EXECUTIVE PARK, BUILDING 13 641 INDUSTRY DRIVE TUKV(ILA, WA 98188 2. APPLICABLE CODES & ORDINANCES: 2015 INTERNATIONAL BUILDING CODE WITH STATEWIDE AMENDMENTS ICC/A14SI A117.1-09, ACCESSIBLE AND USABLE BUILDINGS AND FACILITIES, WITH STATEWIDE AMENDMENTS 2015 INTERNATIONAL RESIDENTIAL CODE WITH STATEWIDE AMENDMENTS 2015 INTERNATIONAL MECHANICAL CODE WITH STATEWIDE AMENDMENTS 2015 INTERNATIONAL FUEL GAS CODE WITH STATEWIDE AMENDMENTS (PART OF THE IMC ADOPTION) 2015 INTERNATIONAL FIRE CODE WITH STATEWIDE AMENDMENTS 2015 UNIFORM PLUMBING CODE WITH STATEWIDE AMENDMENTS 2015 INTERNATIONAL ENERGY CONSERVATION CODE/WASHINGTON STATE ENERGY CODE 2015 INTERNATIONAL EXISTING BUILDING CODE WITH STATEWIDE AMENDMENTS FOUND IN THE IBC NATIONAL ELECTRICAL CODE (NFPA 70) 3. GENERAL BUILDING DESCRIPTION: TYPE OF CONSTRUCTION: TYPE VB FIRE RESISTIVE SYSTEM: NON-SPRINKLERED OCCUPANCY TYPE: F1 AND B OFFICE 4. FIRE RESISTIVE CONSTRUCTION REQUIREMENTS: SHAFT ENCLOSURES: N/A EXIT STAIR ENCLOSURES: N/A CORRIDORS: N/A 5. EXITS: APPROXIMATE AREA OF CONSTRUCTION: 6,114 SQFT TOTAL APPROXIMATE SUITE AREA: OFFICE: 1,618 SQFT (SEE G.O.2 PLAN FOR DETAILS) OCCUPANT LOAD FACTOR: OFFICE: 100, TRAINING: 20, ASSEMBLY: 15, KITCHEN: 200, WAREHOUSE: 500 NUMBER OF TOTAL PROPOSED OCCUPANTS: 86 OCC. (SEE G.O.2 PLAN FOR DETAILS) NUMBER OF EXITS REQUIRED: 2 REQUIRED; 2 PROVIDED MINIMUM EGRESS WIDTH REQUIRED: 3'-81' MAXIMUM COMMON PATH OF EGRESS TRAVEL: 75' (ACTUAL: 52'-8") 6. PROJECT DESCRIPTION: NON-STRUCTURAL INTERIOR TENANT IMPROVEMENT. WORK INCLUDES NON-STRUCTURAL DEMOLITION, NEW PARTITIONS, DOORS, SIDELIGHTS, CASEWORK AND FINISHES. 7. TENANT USE OF SITE: NATIONAL CORPORATE FOOD SERVICE SALES OFFICE, DISTRIBUTIONA AND TRAINING ROOM FOR DEMONSTRATIONS & MARKETING STRATEGIES. STREET MAAP DEFINITIONS AND DIMENSIONS KEY PLAN FLOOR PLATE 1 :25' A. DEFINITIONS: ANDOVER EXECUTIVE PARK BUILDING 13 1. "TYPICAL" OR "TYP" INDICATES IDENTICAL COMPLETE SYSTEM FOR THE CONDITION NOTED. 641 INDUSTRY DRIVE EXIT EXIT EXIT TUKWILA, WA 98188 2. "SIMILAR" OR "SIM." INDICATES COMPLETE SYSTEM AND COMPONENTS COMPARABLE TO THE CHARACTERISTICS FOR THE CONDITION NOTED. 3. "AS REQUIRED" INDICATES CONTRACTOR SHALL PROVIDE COMPONENTS REQUIRED TO COMPLETE THE NOTED SYSTEM AS INDICATED IN THE PROJECT DOCUMENTS. SYMBOLS 4. "ALIGN" INDICATES ACCURATELY PROVIDE FINISH FACES OF MATERIALS IN STRAIGHT, TRUE, AND PLUMB RELATION ADJACENT MATERIALS. ELEVATION REFERENCE SYMBOL INDICATES FINISHED 5. "CLEAR" INDICATES CRITICAL DIMENSION AND SHALL SET PRECEDENT FOR LAYOUT OF U - DETAIL ID SURFACES TO ALIGN PARTITIONS. L'� Ah, R DRAWING TITLE BAR DETAIL IDENTIFICATION B. DIMENSIONS: SHEET NO. DRAWING TITLE 1. DIMENSIONS ARE INDICATED TO THE FACE OF FINISHED SURFACE AT ALL NEW AND D GRAPHICAL SCALE EXISTING CONSTRUCTION, CENTER OF COLUMNS OR GRID LINES UNLESS OTHERWISE NOTED. .SECTION REFERENCE SYMBOL �TITLE I 2. ALIGNMENT OF PARTITIONS AND FINISHES AS SCHEDULED SHALL BE STRAGHT, TRUE & LONGEST COMMON 0 V PLUMB. DIMENSIONAL LAYOUT SHALL BE IN THE FOLLOWING PRIORITY ORDER. PATH OF EGRESS A. STRUCTURAL DRAWINGS TRAVEL: 52'-8" FLOOR ELEVATION SYMBOLS B. LARGE SCALE DETAILS ,k 92'-0" +1'-0" NOMINAL FLOOR C. SMALL SCALE DETAILS _T - /_ ELEVATION D. ENLARGED PLANS AND SECTIONS DETAIL REFERENCE SYMBOL HEIGHT (ABOVE/BELOW) E. FLOOR PLANS K_DT_LN� BUILDING SPACE / ROOM ID 3. MINIMUM DIMENSIONS FOR ACCESSIBILITY CLEARANCES AND BUILDING CODE OFFICE SPACE NAME REQUIREMENTS SHALL BE MAINTAINED. k\�, EME 3 a COLUMN AND/OR GRID LINE SYMBOL 1127 SPACE NUMBER 4. FLOOR ELEVATIONS ARE INDICATED AT THE FACE OF THE STRUCTURAL SLAB, UNLESS 0 DIMENSION LINE: DOOR SYMBOL OTHERWISE NOTED. 20' - 0 5. VERTICAL DIMENSIONS ARE INDICATED FROM THE FLOOR ELEVATION TO FACE OF Ilk FINISHED MATERIAL, UNLESS NOTED ABOVE FINISH FLOOR - "AFF". DOCUMENT SHEET SYMBOL 6. CEILING HEIGHTS ARE INDICATED FROM THE FLOOR ELEVATION TO THE FACE OF SUSPENDED ACOUSTIC CEILING GRID OR FACE OF FINISH MATERIAL FOR OTHER CEILING Z_ ANGLE q> KEYED SHEET NOTES TYPES, UNLESS OTHERWISE NOTED. EXIT @ AT GLAZING SYMBOL 7. DOCUMENTS ARE -DRAWN DIAGRAMMATICALLY, AND SCALED DIMENSIONS ARE APPROXIMATE. CENTERLINE DIMENSIONS SHALL INDICATE REQUIRED SIZE, CLEARANCES, AND RELATIONSHIPS ARE A REVISION NUMBER INDICATED BY DIMENSIONS AS NOTED. PROJECT TEAM TENANT: Western Foods ANDOVER EXECUTIVE PARK, BUILDING 13 641 INDUSTRY DRIVE TUKWILA, WA 98188 ATTN: BILL HEPLER ARCH ITECT/DESIGN ER: Burgess Design, Inc. 1326 - 5th Avenue, Suite 400 Seattle, Washington 98101 Tel: 206.587.7120 Fax: 206.587.7122 ATTN: RANDY MORGAN BUILDING PROPERTY MANAGER: Scanlan Kemperbard Companies 617 Industry Drive Tukwila, Washington 98188 Tel: 206.575-6675 Fax: 206.587.7122 ROSS BECKLEY GENERAL CONTRACTOR: "0 TBD 'o PLUMBING ENGINEER: 7 TBD - Bidder Design Build by G.C. MECHANICAL ENGINEER: 7 TBD - Bidder Design Build by G.C. ELECTRICAL ENGINEER: 0 TBD - Bidder Design Build by G.C. FIRE/LIFE SAFETY ENGINEER: TBD - Bidder Design Build by G.C. PLUMBING, MECHANICAL, ELECTRICAL, LIFE SAFETY PERMITS UNDER SEPARATE SUBMITTALS. LEGAL DESCRIPTION / PARCEL NO. PARCEL NUMBER: 022340-0010 , FILI, Co LEGAL DESCRIPTION: ANDOVER INDUSTRIAL PARKJ5 LESS UP RR20 rr/w R � Poermit F40, LR H (9 Plan "PProva "Dview . - 1 If)' 3-ublect to errors and omi,sions. Approval of construction documents does not awki'loizo the violation of any adopted code or ordinance. l:3eceipt Of approved Field . Copy ond" is acknOwledgad: f3y: Date: . . . . ...... CitY Of Tukwila BUILDING DIVISION DRAWING DRAWING ISSUED 'o "0 '0 'o 0 7 7 7 7 7 0 n N 0 0- 10.21.16 0 0 0 0 tpprovah)t- iivision-I pIaniSUbMAt86ic Stamp Location revirm foes. I INDEX IXIXIXIXIXI I I G.O.0 COVER SHEET / PROJECT INFORMATION IXIXIXIXIXI -1 1 G.O.1 PROJECT NOTES I I X I X I X I X I i I G.O.2 SITE PLAN/PLUMBING EXIT NG PLAN Tenant: WESTERN FOODS/CORE GROUP ANDOVER EXECUTIVE PARK BUILDING 13 641 INDUSTRY DRIVE TUKWILA, WA 98188 A Tenant Improvement for: SKB COMPANY ANDOVER EXECUTIVE PARK 617 INDUSTRY DR. TUKWILA, WA 98188 BURGESS INTERIOR ARCHITECTURE 1326 Fifth Avenue, Suite 400 1 Seattle, WA 98101 T 206 587 7120 W BurgessPNW.corn All reproduction & intellectual property rights reserved c 2015 Approved by: Date: CONSTRUCTION WORK SHALL NOT PROCEED UNTIL THE BUILDING OWNER / REPRESENTATIVE AND BUILDING TENANT HAVE GIVEN THEIR APPROVAL TO THESE CONSTRUCTION DOCUMENTS. APPROVAL BY THESE PARTIES SHALL BE INTERPRETED AS APPROVAL OF DRAWINGS FOR CONTENT, FINISH SELECTIONS, SCOPE OF WORK, AND ALL DIMENSIONS REGARDED BY EITHER PARTY AS BEING NECESSARY TO THEIR OPERATIONS, USE OF THE SPACE, FURNISHINGS, AND TENANT EQUIPMENT AND FURNITURE INSTALLATIONS. CONSTRUCTION AND/OR INITIATION OF CONSTRUCTION, AUTHORIZED BY THE BUILDING OWNER FROM THESE CONSTRUCTION DOCUMENTS, SHALL BE INTERPRETED BY THE DESIGNER AS APPROVAL IN FULL OF THESE CONSTRUCTION DOCUMENTS BY BOTH THE BUILDING OWNER REPRESENTATIVE AND THE TENANT. Professional seal LLL ALAN MORGAN OF WASHINGTON 3 rZ R'� R �71 r:-! EJ P 2 � 4 1 T No. Issue Description Date Az-QU2,E_--D FOFI: REVIEW SET 08.15.16 0,10achanled Electricd REVISED REVIEW SET 08.23.16 FINAL REVIEW SET 09.12.16 Gas Piping CRY of TUkW11a !k!!LD1 G DIVISION PERMIT SET 09.20.16 A CORRECTIONS SET 10.21.16 REVISIONSI Ho changes ihall be mn( of work witholit prior; Tukwila Building C NOTE: Revisions will require alnew and may include additional 01an e to the scope tpprovah)t- iivision-I pIaniSUbMAt86ic Stamp Location revirm foes. I REVIEWED FOR CODE COMPLIANCE APPROVED NOV 2 2 2016 City of TILa BUILDING DIVISION CORRECTION LTR# -----1 P 7 0 RECEIVED CITY OF TUKWILA OCT 24 2016 PERMIT CENTER Drawn by: JG/MK Project Manager: RM Project No: 16.3405.00 COVER SHEET / PROJECT INFORMATION Original drawing is 24" x 36". Scale entities accordingly if reduced G,000 PROJECT NOTES 1. THESE PROJECT NOTES ARE GENERIC IN NATURE. CONTRACTORS INSTRUCTIONS FOR CONSTRUCTION ADMINISTRATION MAY VARY BASED ON THE CONTRACT BETWEEN BUILDING MANAGEMENT AND TENANT. VERIFY WITH BUILDING MANAGEMENT ALL CONSTRUCTION REQUIREMENTS AND CONSTRUCTION ADMINISTRATION RESPONSIBILITIES. THE DESIGNER MAY NOT HAVE CONSTRUCTION ADMINISTRATION OBLIGATIONS. 2. PLUMBING, ELECTRICAL, MECHANICAL & LIFE SAFETY SHALL BE PERFORMED UNDER THE DESIGN/BUILD CONTRACT, UNO. ALL WORK SHALL BE TO CODE. ANY INFORMATION ON THESE DRAWINGS ARE FOR REFERENCE AND SCHEMA11C DESIGN ONLY. CONTRACTOR IS RESPONSIBLE FOR ALL ASPECTS OF THE DESIGN. VERIFY REQUIREMENTS OF BUILDING MANAGEMENT AND TENANT. REVIEW OF SHOP DRAWINGS, IF APPROPRIATE, IS FOR AESTHETIC REASONS ONLY. 3. VERIFY BUILDING STANDARDS WITH BUILDING MANAGEMENT WHEN WORKING IN SUITES WITH NON BUILDING STANDARD ELEMENTS. VERIFY PREFERRED DETAILING OF THESE ELEMENTS WITH BUILDING MANAGEMENT. 4. VERIFY ALL RULES, GENERAL CONDITIONS AND SPECIALIZED BUILDING REQUIREMENTS WITH THE BUILDING MANAGEMENT. 5. VERIFY LEED REQUIREMENTS WITH BUILDING MANAGEMENT. DIVISION I - GMERAIL COND1111110INIS 1. GENERAL DESCRIPTION OF THE PROJECT. NON-STRUCTURAL INTERIOR TENANT IMPROVEMENT OF A COMMERCIAL OFFICE SUITE. UON. 2. WHERE NO BUILDING STANDARDS EXIST FOR MATERIALS CALLED OUT AS "BUILDING STANDARD- ON THE PLANS, THE CONTRACTOR SHALL SO ADVISE BURGESS DESIGN WITHIN TEN (10) DAYS OF THE CONTRACTOR'S RECEIPT OF THE PLANS SO THAT BURGESS DESIGN MAY MAKE ALTERNATE SELECTIONS. 3. CONTRACTOR SHALL VERIFY ALL REQUIREMENTS OF EXACT SIZE AND QUANTITY OF EQUIPMENT FURNISHED BY THE TENANT, INCLUDING REQUIREMENTS FOR MECHANICAL AND ELECTRICAL SERVICES, AND IS RESPONSIBLE FOR ALL ROUGH -IN CONNECTIONS. EACH SUBCONTRACTOR IS RESPONSIBLE FOR ANY DAMAGE TO ADJACENT WORK AND SHALL REPAIR SAID DAMAGE AT THEIR OWN EXPENSE. 4. FIRE/EMERGENCY SYSTEMS INCLUDE, BUT ARE NOT LIMITED TO, SPRINKLER MODIFICATIONS, FIRE EXTINGUISHER PLACEMENT, AUDIBLE ALARMS, SMOKE AND HEAT DETECTORS, STROBES, AND EXIT SIGN PLACEMENT. 5. ALL DESIGN BUILD INFRASTRUCTURE SHALL BE UNDER A SEPARATE PERMIT BY CONTRACTOR. 6. WORK NOT INCLUDED: CONTRACTOR SHALL PROVIDE THE FOLLOWING ITEMS DESCRIBED IN THE SPECIFICATIONS AND SHOWN ON THE PLANS EXCEPT FOR THE ITEMS INDICATED "N.I.C.- (NOT IN CONTRACT), SUCH AS TELEPHONE AND DATA CABLES, OFFICE FURNITURE, EQUIPMENT AND MOBILE KITCHEN APPLIANCES. 7. CONTRACTOR TO PROVIDE ALL FIRE/EMERGENCY SYSTEMS AS REQUIRED BY ALL APPLICABLE CODES. FIRE/EMERGENCY SYSTEMS INCLUDE BUT NOT LIMITED TO SPRINKLER MODIFICATIONS, FIRE EXTINGUISHERS, AUDIBLE ALARMS, STROBES, SPRINKLERS, SMOKE AND HEAT DETECTORS, AND EXIT SIGNS. 8. EVERY EXIT DOOR SHALL BE OPERABLE FROM THE INSIDE WITHOUT THE USE OF A KEY OR ANY SPECIAL KNOWLEDGE OR EFFORT, AND SHALL BE EQUIPPED WITH PANIC HARDWARE WHERE REQUIRED AND INDICATED. 9. ANY MATERIAL USED IN CONSTRUCTION SHALL MEET CURRENT FLAME CODE REGULATIONS. 10. ALL ELECTRICAL, PLUMBING AND MECHANICAL MATERIAL INSTALLATIONS SHAH COMPLY WITH THE BUILDING SHEH STANDARD SPECIFICATIONS. 11. THE GENERAL CONTRACTOR SHALL LAY OUT THE WORK IN CONFORMITY WITH THE REQUIREMENTS OF CONTRACT DOCUMENTS, AND WILL BE HELD RESPONSIBLE FOR PROPER ESTABLISHMENT AND MAINTENANCE OF ALL LINES AND DIMENSIONS. BEFORE DOING AND WORK, THE GENERAL CONTRACTOR SHALL VERIFY ALL MEASUREMENTS AND CONDITIONS AT THE SITE AND NOTIFY THE ARCHITECTS OF ANY DISCREPANCIES. 12. THE CONTRACTORS SHALL USE DIMENSIONS ONLY. DO NOT SCALE PLANS. ALL DIMENSIONS ARE TO FINISHED FACE UNLESS OTHERWISE NOTED. 13. MATERIALS: ALL MANUFACTURED ARTICLES, MATERIALS, AND EQUIPMENT SHALL BE APPLIED AS RECOMMENDED BY MANUFACTURERS. ALL LIKE MATERIALS USED SHALL BE OF THE SAME MANUFACTURER AND QUALITY UNLESS OTHERWISE SPECIFIED. ALL MATERIAL, EQUIPMENT AND FIXTURES SHALL BE CODE WORTHY WITH ALL PROPER JURISDICTIONAL APPROVALS. 14. CONFIRM LONG LEAD ITEMS AT THE START OF THE JOB AND REPORT TO DESIGNER AND BUILDING MANAGEMENT ANY SCHEDULE CONFLICTS. 15. CONFIRM ALL WARRANTEE PERIOD WITH BUILDING MANAGEMENT. IN LIEU OF STANDARD ALL WORK SHALL BE WARRANTED FOR ONE YEAR. 16. CONFIRM STRUCTURAL SYSTEM OF BUILDING AND USE APPROPRIATE CONNECTION TECHNICS. UTILIZE REBAR OR TENDON DETECTION TECHNOLOGY TO LOCATE EXISTING STRUCTURE IN CONCRETE SLABS AND OTHER ON SITE CONDITIONS. DIVISON 0 - SFTIE WORK MO DEkUXMON 1. FURNISH ALL LABOR, MATERIALS AND EQUIPMENT AS REQUIRED TO COMPLETE THE DEMOLITION AND REMOVAL OF ALL ITEMS LOCATED IN THE CONSTRUCTION AREAS. UPON COMPLETION OF ALL DEMOLITION WORK, ALL AREAS SHALL BE LEFT BROOM CLEAN. 2. DEMOLITION OF TELEPHONES, ELECTRICAL, VCICE/DATA AND PANELS ARE TO BE REMOVED BACK TO ORIGINATING SOURCE. DEMOLITION OF CORES AND RELATED CABLING TO BE REMOVED FROM TENANT SPACES BELOW. 3. DURING THE REMOVAL OF ANY ENVIRONMENTALLY HAZARDOUS MATERIALS, PROTECTION GUIDELINES SHOULD BE STRICTLY FOLLOWED BY CODE OR LOCAL GOVERNING AUTHORITY. VERIFY ALL REQUIREMENTS WITH BUILDING OWNER. 4. ALL EXISTING CONSTRUCTION ITEMS THAT INTERFERE WITH THE CONSTRUCTION NEGOTIATED BY THE PRICING PLAN / SPACE PLAN WITH WORK LEITER SHALL BE REMOVED, RELOCATED, OR KEPT FLUSH IN CEILING, WALL, OR FLOOR AS REQUIRED. 5. ALL DAMAGED, ALTERED OR REWORKED AREAS SHALL BE PATCHED AS REQUIRED AND FINISHED TO MATCH EXISTING ADJACENT AREAS OR AS SPECIFIED TO PROVIDE A "LIKE -NEW FINISH". 6. CONTRACTOR SHALL PROVIDE PLASTIC SHEETING OR OTHER APPROPRIATE BARRIER TO CONTROL DUST AND DEBRIS SUCH THAT IT DOES NOT AFFECT AREAS OUTSIDE THE AREA OF WORK. 7. CONTRACTOR SHALL PROVIDE ALL DUE CAUTION FOR SITE WORK. CALL 811 BEFORE STARTING ANY SITE WORK. WISON V! - ARGHTTECTURAL CARPEIM AND rAS3= 1. ROUGH CARPENTRY TO INCLUDE ANY WOOD STUDS, FURRING, BLOCKING, ROUGH FRAMING, WOOD CURBS, BUCKS, NAILERS, BACKING, FIXTURE FRAMING, EQUIPMENT SUPPORTS, ETC. AS DETAILED. 1. FINISH CARPENTRY TO INCLUDE INSTALLATION OF ALL FIXTURES AND ASSOCIATED TRIMS, HARDWARE AND NOSINGS. 2. PROVIDE INTERIOR DOOR AND SIDELIGHT FRAMES AS SCHEDULED. 3. CABINET CONSTRUCTION: COMPLY WITH THE A.W.I. ARCHITECTURAL WOODWORK QUALITY STANDARDS FOR CUSTOM GRADE WORK. CABINETS SHALL BE FLUSH CONSTRUCTION. 4. PROVIDE PARTICLE BOARD, MED. DENSITY, WEIGHING <40 LB./CU. Fr., AT LEAST 3/4" THICK. 5. CABINET HARDWARE: FULL EXTENSION DRAWER GLIDES, STAINLESS STEEL CABINET PULLS, US32D FINISH, AND CONCEALED DOOR HINGES, SHELF HARDWARE AND OTHER REQUIRED ITEMS, UON IN ELEVATIONS / DETAILS, OR PER BUILDING STANDARD. 6. PLASTIC LAMINATE: HIGH-PRESSURE DECORATIVE LAMINATE SELECTED FROM WILSONART, NEVAMAR, AND FORMICA, UON. LAMINATE TO BE GENERAL-PURPOSE GRADE .050" HORIZONTAL AND .030" VERTICAL. SHELVING SHALL COMPLY WITH AWI SECTION 600. 7. CABINET HINGES SHALL BE 135 DEGREE FRAMELESS CONCEAl ED EUROPEAN STYLE HINGE AND FULL EXTENSION HEAVY DUTY DRAWER GLIDES, UNO. CORNER UNITS SHALL BE 94 DEGREE HINGES. 8. INTERIOR CABINET SURFACES & SHELVES TO BE OF PREFINISHED BOARD WITH POLYESTER OVERLAY, UON. 9. SHELF EDGING TO BE P -LAM, LION. 10. SUBMIT SHOP DRAWING SUBMITTALS FOR ARCHITECT REVIEW. 1. WHEN PROJECT CONSISTS OF NEW RESTROOMS OR SHOWERS OR OTHER TYPES OF BUILD OUT. GC SHALL VERIFY ALL WATERPROOFING REQUIREMENTS WITH BUILDING MANAGEMENT. PROVIDE WATERPROOFING PER MANUFACTURE'S SPECIFICATION. 2. ROOF WORK SHALL BE DONE UNDER BUILDING MANAGEMENTS WARRANTEE POLICY. VERIFY ALL REQUIREMENTS WITH BUILDING MANAGEMENT. 1. PROVIDE AND INSTALL INTERIOR SUITE DOORS AS INDICATED ON DRAWINGS. 2. DOOR SCHEDULE SPECIFIES FINISH (BOTH SIDES OF DOOR) AND FRAME, UON. 3. DOORS SHALL BE PRE -MACHINED FOR HARDWARE PER HARDWARE SCHEDULE. 4. SUBMIT SHOP DRAWING SUBMITTALS FOR ARCHITECT REVIEW. 5. CONTRACTOR SHALL REVIEW SUITE FOR DOOR STYLE CHANGES AND VERIFY WITH ARCHITECT AND BUILDING MANAGEMENT THE DOOR AND SIDELIGHT STYLE TO MATCH IF A VARIATION IS PRESENT. 6. PROVIDE FIRE PROTECTION IN ALL PENETRA71ONS IN RATED ASSEMBLIES. 7. IN OPEN CEILING CONDITIONS REPAIR OR REPLACE FIRE PROTECTION AS NEEDED. 8. IF SPRAY ON FIREPROOFING IS VISIBLE AND TO RECEIVE PAINT FINISH PROVIDE A SMALL AREA MOCK UP OF BOTH FIRE PROOFING AND WALL SURFACE SO THAT THE COLOR CAN BE CORRECTED DUE TO THE SUBSURFACE CONDITIONS OF DISSIMILAR MATERIALS. 9. PATCH AND REPAIR ANY FIREPROOFING AT SHAFTS, CORRIDORS AND OTHER RATED ASSEMBLIES AS NEEDED. MATCH EXISTING RATINGS AND CONDITIONS. PROVIDE FIRESTOPPPING, SEALANT AND OTHER FIRE RATED ASSEMBLIES AS NEEDED. VERIFY WITH BUILDING MANAGEMENT PREFERRED METHODS AND MATERIALS. 6. FINISH AND SPECIALTY HARDWARE INCLUDES ALL ACCESSORIES, TOOLS, AND FASTENERS REQUIRED FOR HARDWARE INSTALLATION AND MAINTENANCE. ITEMS NOT SPECIFICALLY MENTIONED, BUT NECESSARY TO COMPLETE THE WORK, SHALL BE FURNISHED MATCHING IN QUALITY AND FINISH OF SPECIFIED IN SIMILAR LOCATIONS. 7. PROVIDE ALL HARDWARE AS SPECIFIED PER THE HARDWARE SCHEDULE. 8. ALL LOCK SETS SHALL CONFORM TO THE BUILDING'S GRAND MASTER KEYING SYSTEMS. PROVIDE AT LEAST TWO (2) KEYS FOR EACH LOCK AND TWO (2) MASTER KEYS FOR THE SUITE. ALL KEYS TO BE TAGGED WITH ROOM NUMBERS. CONFIRM QUANTITY WITH BUILDING MANAGEMENT. 9. SUBMIT HARDWARE SCHEDULE WITH CATALOGUE CUT SHEETS FOR ARCHITECT REVIEW. 10. ALL DOORS SHALL HAVE A MINIMUM OF 1-1/2 PAIR OF BUTT HINGES, ONE LATCHSET OR LOCK SET, AND ONE DOOR STOP TO MEET ACCESSIBILITY REQUIREMENTS. 11. ALL HARDWARE SHALL BE COMMERCIAL GRADE AND RATED AT REQUIRED ASSEMBLIES. 12. PROVIDE CLOSERS PER HARDWARE SCHEDULE AND AT ALL RATED ASSEMBLIES. 13. ALL HARDWARE SHALL MATCH BUILDING STANDARD IN STYLE AND FINISH. 14. SET UNITS LEVEL, PLUMB AND TRUE TO LINE AND LOCATION. ADJUST AND REINFORCE THE ATTACHMENT SUBSTRATE AS NECESSARY FOR PROPER INSTALLATION AND OPERATION. 15. ADJUST AND CHECK EACH OPERATING ITEM OF HARDWARE AND EACH DOOR TO ENSURE PROPER OPERATION OR FUNCTION OF EVERY UNIT. REPLACE UNITS WHICH CANNOT BE ADJUSTED TO OPERATE FREELY AND SMOOTHLY AS INTENDED FOR THE APPLICATION MADE. 16. PROVIDE PROPER SMOKE GASKETS AT RATED ASSEMBLIES. 17. THE FOLLOWING UL LISTINGS ARE REQUIRED ON THE FOLLOWING HARDWARE: PANIC HARDWARE - UL #305 FIRE EXIT HARDWARE - UL #106 & UL #305 ELECTROMAGNETIC LOCK HARDWARE - UL # FWAX-S-A-6635 THE CRASH BAR MUST BE AT LEAST 1/2 OF THE DOOR WIDTH AND OPEN FORCE NO MORE THAN 5 LBS. VERIFY WITH BUILDING STANDARD & MANAGEMENT AND INFORM ARCHITECT IF BUILDING STANDARD DOESN'T COMPLY. 18. ALL EXTERIOR DOORS SHALL HAVE CODE REQUIRED U VALUE AND WEATHER STRIPPING. 19. ALL GLASS AT SIDELIGHTS AND DOORS SHALL BE 1/4- TEMPERED SAFETY GLAZING, UON. 20. CONTRACTOR SHALL VERIFY GLASS THICKNESS IS APPROPRIATE FOR DIMENSIONS AND SPANS. 21. THIS PROJECT MAY CONTAIN GLAZING THAT WILL BE SUBJECT TO FEDERAL GLAZING STANDARDS. GLAZING SUBCONTRACTOR SHALL BE RESPONSIBLE FOR ADHERENCE TO THE REQUIREMENTS. IF GLAZING SUBCONTRACTOR FINDS ANYTHING IN THE DOCUMENTS NOT IN COMPLIANCE WITH THE STANDARD, THEY SHALL BRING DISCREPANCIES TO THE ATTENTION OF THE ARCHITECT BEFORE PROCEEDING WITH THE WORK. 22. RATED GLASS (CERAMIC) RELITE SHALL BE PREMIUM POLISHED FINISH. GLAZING SHALL COMPLY WITH IBC 716.3 DIVEM OX - FINISHES 1. INCLUDE NECESSARY MATERIALS, LABOR AND ACCESSORIES FOR THE INSTALLATION OF ALL PARTITIONS AS SHOWN IN THE PLANS. 2. "WALL SURFACES* MEAN ALL VERTICAL SURFACES INCLUDING COLUMNS WHERE EXPOSED, CONVECTOR OR RADIATOR ENCLOSURES, FASCIAS, RETURNS, PLYWOOD BACKBOARDS, ETC. 3. ALL PARTITION HEADS SHALL MATCH BUILDING STANDARD, UON. 4. WALLS SHOWN ALIGNED WITH BASE BUILDING STRUCTURE SHALL BE FLUSH AND SMOOTH WITH BASE BUILDING STRUCTURE, UON. 5. SEISMIC BRACING: PROVIDE SEISMIC BRACING AS REQUIRED PER THE LATEST BUILDING CODES TO THE PARTITION HEADS AND CEILING GRID. 6. FRAMING STUDS: GALVANIZED STEEL STUDS PER CONSTRUCTION PLANS. PROVIDE WITH SHEET METAL BACKING WITHIN ALL WALLS RECEIVING CASEWORK (CABINETS, BOOKSHELVES, ETC.). VERIFY STUD SIZE MATCHES DOOR FRAMES IN STOCK IF APPLICABLE. 7. CONTRACTOR SHALL PROVIDE AND LOCATE ACCESS PANELS AS REQUIRED AFTER INSTALLATION OF MECHANICAL DUCTS, PLUMBING, AND ELECTRICAL WORK. FIRE RATE AS REQUIRED. 8. ALL DRYWALL TO BE 5/8' TYPE Y UNLESS OTHERWISE NOTED. PROVIDE "M/R" TYPE DRYWALL OR CEMENT BOARD WHERE REQUIRED BY CODE AND AT ALL TOILET ROOMS, AND BEHIND CERAMIC TILES, UON. 9. INSTALL CORNER BEADS AT ALL EXTERNAL CORNERS. INSTALL METAL EDGE TRIM WHENEVER EDGE OF GYPSUM BOARD WOULD OTHERWISE BE EXPOSED OR SEMI -EXPOSED. 10. PRIOR TO RECEIVING FINISH, ALL SURFACES SHALL BE PROPERLY PREPARED AS REQUIRED TO RECEIVE FINAL FINISHING AS SPECIFIED. 11. EXTEND ALL SOFFIT FRAMING TO STRUCTURE ABOVE. PROVIDE STRUCTURAL DIAGONAL BRACING AS NECESSARY. 12. PROVIDE FRAMING FOR SUSPENDED CEILING WITH SEISMIC BRACING IN ACCORDANCE WITH REQUIREMENTS OF APPLICABLE CODES AND AS SHOWN ON DRAWINGS. 13. USE ACOUSTICAL SEALANT AROUND ALL PIPES, DUCTS, CONDUIT, OUTLETS, SWITCHES, ETC. ON BOTH SIDES OF CROSSING/PENETRATING WALLS WITH ACOUSTICAL INSULATION. PENETRATIONS OF FIRE -RATED WALLS SHALL BE PROTECTED BY APPLICABLE FIRE -RATED ASSEMBLIES AND MATERIALS. 14. FIRE AND SMOKE SEPARATION ASSEMBLIES SHALL BE MARKED AS REQUIRED IN IBC SECTION 703.7. 15. PROVIDE NEW CEILING TILE, CEILING GRID AND ALL ACCESSORIES AS REQUIRED TO INSTALL SUSPENDED ACOUSTICAL CEILINGS AS INDICATED ON DRAWINGS. 16. PROVIDE SEISMIC BRACING AS REQUIRED BY CODE AT NEW CEILING WORK ONLY. VERIFY WITH BUILDING MANAGEMENT IF EXISTING CONDITIONS ARE SEISMICALLY BRACED OR PROVIDE PER CODE. 17. COORDINATE WORK WITH OTHER TRADES HAVING WORK IN THE CEILING AND THE TELEPHONE AND DATA CABLE COMPANIES WHEREVER THEIR RESPECTIVE WORK IS CONTIGUOUS. 18. PROVIDE CUTOUTS AND OTHER SPECIAL PROVISIONS IN ACOUSTICAL WORK AS REQUIRED FOR LIGHTING FIXTURES, REGISTERS, DIFFUSERS, SPRINKLERS, AND OTHER INSERTED ITEMS. 19. ALL CUTOUTS SHALL BE CENTERED WITHIN ACOUSTIC CEILING TILE, UON. 20. ALL MATERIALS SHALL HAVE CLASS 1 FLAME SPREAD RATING AND BE INSTALLED IN ACCORDANCE WITH MANUFACTURER'S SPECIFICATION AND CODES. 21. ALL JOINTS IN THE TILE FIELD SHALL BE SQUARE, LEVEL AND PERFECTLY ALIGNED WITH EACH OTHER. 22. INSTALLED SUSPENDED CEILINGS TO BE LEVEL WITHIN A TOLERANCE OF 1/8- IN 12'-0-. ANCHOR AS REQUIRED. 23. IN AREAS OF ALTERATIONS CONTRACTOR SHALL MATCH CONDITIONS AND MAKE EVERY EFFORT TO ALIGN, LEVEL AND MATCH NEW CEILING TO OLD. CONTRACTOR SHALL REVIEW ALL CEILINGS UPON COMMENCEMENT OF THE PROJECT AND INFORM THE BUILDING MANAGEMENT OF ANY DISCON11NUITIES IN THE CEILING WITHIN 10 DAYS. 24. ADJUST PARTITION HEAD DETAIL TO MATCH EXISTING CEILING CONDITIONS IF NECESSARY. 25. IN OPEN CEILING CONDITIONS OR IF CLOUDS ARE SPECIFIED, PROVIDE ALL WORK SUITABLE FOR AN EXPOSED AND VISIBLE CONDITION. HANGING, CONDUIT, DUCTWORK AND OTHER ITEMS SHALL BE PLUM AND TRUE. VERIFY ALL REQUIREMENTS WITH BUILDING OWNER CONCERNING MAINTAINING THE RETURN AIR PLENUM. PROJECTS THAT CONVERT ACT SPACE INTO OPEN SPACE SHALL HAVE THE FINISH OF THE OLD INTERSTITIAL SPACE FINISHED WITH GWB TO A LEVEL FLOOR FINISH, UNO. THIS MAY REQUIRE FURRING OR STUDS EXTENDED TO THE UNDERSIDE OF STRUCTURE. 26. PROVIDE ACOUSTICAL INSULATION BETWEEN FRAMING STUDS AND EXTENDING TWO FEET ON EACH SIDE OF PARTITION HEAD ABOVE CEILINGS FOR ALL WALLS NOTED PER PLANS. 27. NEW DEMISING WALL CONSTRUCTION TO HAVE SOUND BATT INSULATION BETWEEN FRAMING STUDS AND TWO FEET OF INSULATION ON EITHER SIDE OF THE PARTITION HEAD ABOVE CEILING GRID, UON. 28. PROVIDE VCT, SHEET LINOLEUM, SHEET VINYL AND RUBBER BASE AS INDICATED IN DRAWINGS. COLOR AND MANUFACTURER PER FINISH SCHEDULE. 29. PROVIDE RUBBER -REDUCING STRIPS IN COLOR TO MATCH SPECIFIED BASE, UNO. REDUCING STRIPS TO OCCUR AT ALL AREAS OF FLOOR MATERIAL TRANSITION. USE STAINLESS STEEL TRANSITION AT TILE TO DISSIMILAR MATERIAL, UNO. 30. BASE TO BE INSTALLED IN LONGEST AVAILABLE LENGTH WITH NO PIECE LESS THAN 12*. NO JOINTS AT OUTSIDE CORNERS OR WITHIN 6" OF CORNERS. VERIFY HEIGHT OF RUBBER BASE REQUIRED WITH BUILDING MANAGEMENT. 4.5" MAY BE NECESSARY. 31. PATCH, LEVEL AND PREPARE SUB FLOORING WITH CEMENTITIOUS UNDERLAY PER MFR'S WRITTEN INSTRUCTIONS IN AREAS TO RECEIVE NEW FLOORING. MAX. ALLOWABLE TOLERANCE = 1/4* OVER 10'. 32. GENERAL CONTRACTOR SHALL APPLY FLOOR WAX TO NEW FLOORING AREAS PER MANUFACTURERS SPECIFICATION, UON. 33. UNLESS SPECIFIED ALL RUBBER BASE SHALL BE COVED BASE. 34. PROVIDE AND INSTALL COMMERCIAL GRADE CARPET AS INDICATED IN DRAWINGS. 35. PROVIDE SEAMING DIAGRAMS FOR ARCHITECT'S REVIEW. 36. UNLESS OTHERWISE NOTED, PRIME ALL GWB WALL SURFACES AND PAINT WITH MINIMUM OF TWO (2) FINISH COATS OF BENJAMIN MOORE EGGSHELL FINISH LATEX PAINT OR APPROVED EQUAL, UON. PROVIDE FOR NUMBER OF PAINT COLORS AS INDICATED IN ERAWINGS. VERIFY STANDARD LEVEL OFnNISH WITH BUILDING MANAGEMENT. 37. FINISH DOORS, DOOR FRAMES, AND SIDELIGHT FRAMES AS INDICATED IN DRAWINGS. A) PAINTED WOODWORK TO BE FINISHED WITH ONE (1) COAT PRIMER AND TWO (2) FINISH COATS. B) SEALED WOODWORK TO BE STAINED PER FINISH SCHEDULE AND SEALED WITH A COMMERCIAL GRADE CLEAR SATIN VARNISH. 38. PAINT FOR THE LIGHT SURFACES TO CONFORM TO THE REQUIREMENTS OF THE "ARCHITECTURAL SPECIFICATIONS MANUAL" (AWS) FOR PAINT SYSTEMS. LATEX PAINT- AWS SYSTEM 3-B 'CUSTOM' (1) COAT PRIMER AND TWO (2) FINISH COATS. GRADE LIGHT COLOR PAINT FINISH ON GYPSUM BOARD SURFACES. 39. PAINT FOR THE DARK SURFACES TO CONFORM TO THE REQUIREMENTS FOR THE "ARCHITECTURAL SPECIFICATIONS MANUAL" (AWS) FOR PAINT SYSTEMS. LATEX PAINT. AWS SYSTEM 3-B -CUSTOM' (1) COAT PRIMER AND TWO (2) FINISH COATS. GRADE DEEP TONE PANT FINISH ON GYPSUM BOARD SURFACES. 40. UPON COMPLETION OF WORK, REMOVE EXCESS PAINT, STAIN, VARNISH, ADHESIVE, CAULK, ETC. FROM ALL OTHER SURFACES THAT WERE NOT SPECIFIED TO RECEIVE SAME. 41. TOUCH-UP AND PATCH SURFACES AS REQUIRED AFTER THE COMPLETION OF WORK BY OTHER TRADES. 42. WHERE COLUMNS OCCUR IN AREAS SCHEDULED TO BE FINISHED, THEY SHALL RECEIVE THE SAME FINISH AS THE ROOM, UON. 43. ALL PAINTED SURFACES SHALL BE PREPARED IN STRICT ACCORDANCE WITH MANUFACTURER'S SPECIFICATIONS (ESPECIALLY IN REGARD TO THE PRIMING OF EXISTING SURFACES). 44. PUTTY ALL NAIL HOLES, COUNTERSUNK SCREWS, BOLTS, CRACKS, ETC. BEFORE APPL.YING FINISH. 45. SAND ALL WOOD SURFACES SMOOTH AND EVEN BEFORE APPLYING FINISH. 46. SAND ENAMELED FINISHES APPLIED TO WOODS OR METAL BETWEEN COATS WITH FINE SANDPAPER TO PRODUCE SMOOTH FINISH. 47. MAKE FINISH WORK UNIFORM AND SMOOTH, FREE OF RUNS, SAGS, DEFECTIVE BRUSHING AND CLOGGING. MAKE EDGES OF PAINT ADJOINING OTHER MATERIALS OR COLORS SHARP AND CLEAN WITHOUT OVERLAPPING. 48. CHANGE PAINT FORMULATION AS REQUIRED FOR DIFFERENT ENVIRONMENTS, MATERIALS AND SURFACE PREPARATIONS. 49. VERIFY ATTIC STOCK REQUIREMENTS OF ALL FINISH MATERIALS WITH BUILDING MANAGEMENT AND TENANT. DIVISION XH - FURNISHINGS 1. ALL EXISTING INTERIOR AND PERIMETER MINI BLINDS TO BE BAGGED AND CLEANED TO LIKE -NEW CONDITION. 2. ALL PERIMETER GLAZING TO RECEIVE BLINDS AS INDICATED IN DRAWINGS. COORDINATE WITH BUILDING MANAGEMENT. MATCH EXISTING CONDITIONS UON. 3. ALL INTERIOR SIDELIGHTS TO RECEIVE 1" MINI -BLINDS WHERE INDICATED IN DRAWINGS. 4. PROVIDE SAMPLE AND CUT SHEET TO ARCHITECT FOR REVIEW. 5. PROVIDE AND INSTALL ALL CODE REQUIRED SIGNAGE. 6. TENANT'S FURNITURE SHALL BE THE RESPONSIBILITY OF THE TENANT AND THEIR VENDOR. GC SHALL INVITE AND COORDINATE TENANTS VENDOR FOR FIELD MEASUREMENTS AND VERIFICATION OF LAYOUT AND AH ELECTRICAL AND VOICE DATA REQUIREMENTS. 7. FURNITURE SYSTEMS CONNECTIONS (WHIPS) SHALL BE PROVIDED BY TENANT'S FURNITURE VENDOR AND INSTALLED BY THE GC, UNO. GC TO COORDINATE. VERIFY ALL ELECTRICAL AND VOICE DATA CONNECTIONS. DIVISION XXI - FIRE SUPPRESSION 1. ALTER OR INSTALL FIRE PROTECTION SYSTEM PER BUILDING STANDARD, LOCAL REGULATIONS AND ORDINANCES. 2. PROVIDE ALL EMERGENCY LIGHTING, EXIT SIGNS, FIRE ALARM SPEAKERS, STROBES AND BELLS AS REQUIRED BY CODE. DESIGN AND INSTALL THE SAME IN COMPLIANCE WITH THE AMERICANS WITH DISABILITIES ACT. 3. PROVIDE SPRINKLERS, FIRE RATED DOORS AND FRAMES, FIRE EXTINGUISHERS, ETC. AS REQUIRED BY APPLICABLE LOCAL CODES AND LAWS. 4. FIRE EXTINGUISHERS SHALL BE BY UNDERWRITER'S LABORATORY 2A-10BC 5 -LB, MULTIPURPOSE EXTINGUISHER WITH SQUEEZE -TYPE HANDLE AND FLEXIBLE DISCHARGE HOSE WITH VISIBLE PRESSURE GAUGE, UON. 5. FIRE EXTINGUISHERS SHALL BE INSTALLED PER BUILDING STANDARD REQUIREMENTS, UON. VERIFY LOCATION WITH FIRE MARSHALL WHEN REQUIRED BY CODE, PROVIDE 1 WALL MOUNT TYPE IN EACH SERVER ROOM OR LABORATORY. 6. DESIGN BUILD FIRE PROTECTION DRAWINGS SHALL INDICATE: A. LAYOUT, LOCATION, AND SIZE OF SPRINKLER LINES AND HEADS. B. PRESSURE REQUIREMENTS. C. SPRINKLER HEAD SPECIFICATIONS. D. LOCATION OF FIRE PROTECTION RISERS AND WALL HYDRANTS E. CHANGES OF USE SHALL BE RESOLVED FOR NEW OCCUPANCY FIRE FLOW. 7. CONTRACTOR TO PROVIDE INSTALLATION DESIGN DOCUMENTS TO ARCHITECT AND BUILDING OWNER FOR REVIEW AND APPROVAL PRIOR TO INSTALLATION. INCLUDE HORNS AND STROBES. 8. ALL SPRINKLER HEADS SHALL BE CENTERED IN ACOUSTICAL CEILING TILE, UON. 9. USE OF NFPA 13 QUICK RESPONSE HEADS MAY BE REQUIRED. CONTRACTOR SHALL VERIFY EXTENT OF QUICK RESPONSE HEADS BY CITY FOR THIS PROJECT. 10. IF CEILING IS DESIGNED FOR AN OPEN CEILING CONDITION, GC SHALL PROVIDE SPRINKLER HEADS IN AN UPRIGHT CONDITION. WORK SHALL BE VISIBLE AND SUITABLY CONSTRUCTED. DWISM )MI - PLUMBW 1. PROVIDE SUPPLY, WASTE AND VENT LINES, VALVES, FITTINGS, ETC. REQUIRED FOR KITCHEN SINKS, DISHWASHER, REFRIGERATOR, AIR CONDITIONING UNIT(S), VENDING MACHINES, COFFEE MAKER, WATER HEATERS, ETC. 2. ALL FIXTURE INSTALLATIONS SHALL CONFORM TO THE AMERICANS WITH DISABILITIES ACT. 3. PROVIDE NEW PLUMBING FIXTURES AS SPECIFIED PER DRAWINGS, OR PER BUILDING STANDARD, UON. 4. PROVIDE HOI AND COLD WATER TO SINKS/DISHWASHERS IF APPLICABLE. 5. ALL NEW WATER HEATERS ARE TO BE INSTALLED WITH DRIP PAN CONNECTED TO WASTE LINE. VERIFY LOCATIONS WITH BUILDING MANAGEMENT AND INSPECTORS. 6. ALL PLUMBING FIXTURES ARE TO BE INSTALLED TO MEET CURRENT GOVERNING LOCAL AND FEDERAL CODES. 7. CONTRACTOR SHALL PROVIDE INSTALLATION DESIGN DOCUMENTS TO ARCHITECT AND BUILDING OWNER FOR REVIEW AND APPROVAL PRIOR TO INSTALLATION. 8. VERIFY WATER SUPPLY & SEWER DRAIN CAPACITY FOR ENTIRE BUILDING WILL MEET NEW CAPACITY WHEN NEW RESTROOMS ARE ADDED TO BUILDING. QNSON )MII - MMMAMC& 1. PROVIDE BUILDING STANDARD HVAC SYSTEM WITH ALL MATERIALS, LABOR AND ACCESSORIES FOR COMPLETE OPERATION OF SYSTEM. CONTRACTOR TO BALANCE WAC SYSTEM AS REQUIRED. 2. DESIGN BUILD MECHANICAL ENGINEERING DRAWINGS INDICATE: A. DUCTS, AIR MOVEMENT REQUIREMENTS, & SIZES OF GRILLES & REGISTERS. 3. CONTRACTOR TO PROVIDE INSTALLATION DESIGN DOCUMENTS TO ARCHITECT AND BUILDING OWNER FOR REVIEW AND APPROVAL PRIOR TO INSTALLATION. 4. HVAC CONTRACTOR TO CLEAN, REPAIR OR REPLACE SOILED OR DAMAGED HVAC GRILLS, FILTERS AND THERMOSTATS. 5. RE -ZONE, ALTER OR SEPARATE HVAC AS NECESSARY AS DIRECTED BY BUILDING MANAGEMENT FOR ALTERED SUITES. 6. IN OPEN CEILING CONDITIONS DESIGN OF HVAC WILL ACCOUNT FOR CHANGES IN THE RETURN AIR PLENUM. ALL HVAC WILL BE VISIBLE AND OF SUITABLE MATERIAL AND INSTALLATION METHOD. 7. IN HIGHRISE BUILDINGS CONTRACTOR SHALL VERIFY METHOD OF SMOKE CONTROL AND PROVIDE DESIGN CONSIDERATIONS IF NEEDED. DIVISION - ELECTRICAL AND 110ECOMMUNICATHM 1. REUSE EXISTING ELECTRICAL AND DATA AS APPROPRIATE TO MEET THE TENANT'S REQUIREMENTS. REPLACE OUTLET COVER PLATES TO MATCH NEW FINISH IF APPLICABLE. 2. PROVIDE ALL WORK, EQUIPMENT AND LABOR FOR A COMPLETE AND OPERABLE ELECTRICAL SYSTEM. PROVIDE ELECTRICAL OUTLETS PER POWER AND DATA PLAN. 3. PROVIDE MUD RING FOR DATA AND COMMUNICATION AS SHOWN ON THE POWER AND DATA PLAN. EACH MUD RING TO HAVE A MINIMUM NUMBER OF WIRE PULLS AS INDICATED ON DRAWINGS. COORDINATE DATA CABLE CONFIGURATION WITH THE TENANT. 4. ALL OUTLETS AND MUD RINGS TO BE LOCATED AT 18* AFF TO THE CENTER LINE, UON. 5. WHERE MULTIPLE DEVISES OCCUR IN A SINGLE LOCATION, ALL DEVICES SHALL BE GANGED UON. 6. ALL ELECTRICAL OUTLETS WITHIN THE CODE REQUIRED DISTANCE FROM A SINK SHALL BE ON A GROUND FAULT INTERRUPTED CIRCUIT. 7. ALL WIRING DEVICES: SHALL BE BUILDING S TANDARD EXCEPT: "ISOLATED GROUND* OUTLETS SHALL BE ORANGE, *HOSPITAL GRADE ISOLATED GROUND* OUTLETS SHALL BE ORANGE WITH A GREEN DOT, "EMERGENCY* OUTLETS SHALL BE RED, AND "DEDICATED" OUTLETS FOR "CLEAN CIRCUIT" FIXTURES SHALL BE GRAY (UNLESS BUILDING STANDARD DICTATES OTHERWISE). ALL COVER PLATES SHALL BE BUILDING STANDARD FINISH, UON. VERIFY WITH BUILDING MANAGEMENT. 8. PROVIDE SEPARATE CIRCUITS FOR TENANT'S EQUIPMENT (INCLUDING THE TO EPHONE SWITCH, COPIERS, COMPUTERS, ETC.) WHEN NOTED ON THE CONSTRUCTION DOCUMENTS. 9. COORDINATE SCHEDULE WITH FURNITURE VENDOR FOR THE USE OF ELECTRICIANS DURING THE INSTALLATION OF TENANTS NEW FURNITURE. 10. ALL ELECTRICAL WIRING, TELEPHONE AND COMPUTER CABLING, AND CONDUIT SHALL BE CONCEALED IN FLOORS, WALLS, OR CEILINGS. CABLING FOR VOICE AND DATA TO BE PROVIDED BY TENANT'S VENDORS AND SHALL BE COORDINATED BY THE BUILDING MANAGER, UNO. 11. THE CONTRACTOR IS TO COORDINATE WITH THE TENANTS SUPPLIED FURNITURE SYSTEMS TO INCLUDE BUT NOT LIMITED TO: ELECTRICAL AND DATA WIRING LOCATIONS, J -BOX LOCATIONS, CONNECTIONS AND WALL MOUNTED REQUIREMENTS. 12. THE CONTRACTOR IS TO VERIFY EXISTING ABANDONED CORE DRILL LOCATIONS AND FILL AS REQUIRED WITH MATERIAL TO MEET CURRENT FLAME SPREAD REGULATIONS. LOCATIONS TO BE PREPARED TO RECEIVE NEW FLOOR FINISH AS REQUIRED. FLOOR SHALL BE LEFT FLUSH. 13. ARCHITECTURAL DRAWINGS INDICATE LOCATION ONLY OF DEVICES SHOWN. SWITCHING AND CIRCUTTING SHALL BE INDICATED ON SEPARATE ELECTRICAL ENGINEERING AS -BUILT DRAWINGS AND SHALL MEET OWNER'S GUIDELINES. 14. ALL TELEPHONE, ELECTRICAL, COMMUNICATION AND SECURITY WORK SHALL BE COMPLETED IN ACCORDANCE WITH ALL APPLICABLE CODES. 15. DRAWINGS INDICATE ALL DIMENSIONS TO CENTERLINE OF TELEPHONE, ELECTRICAL, AND COMMUNICATION COVER PLATE. OUTLETS SHOWN GROUPED TOGETHER ON PLAN SHALL BE SET TO A MINIMUM DIMENSION BETWEEN EACH DEVICE. 16. BACK-TO-BACK OUTLETS ARE NOT PERMITTED. OFFSET OUTLETS THE MINIMUM DIMENSION REQUIRED FOR ACOUSTICAL CONTROL 17. LOCATION OF ALL WALL MOUNTED POWER AND DATA DEVICES SHALL BE FIELD REVIEWED BY THE TENANT BEFORE INSTALLATION. 18. ELECTRICAL ENGINEER TO PROVIDE DESIGN/BUILD PACKAGE TO ARCHITECT FOR REVIEW PRIOR TO INSTALLATION. 19. THE LAYOUT DIAGRAMS COORDINATE LOCATION OF POWER & DATA DEVICES. REFER TO DESIGN/BUILD DOCUMENTS FOR SCOPE, TECHNICAL LAYOUT AND SPECIFICATIONS FOR EACH DISCIPLINE. 20. ARCHITECTS DOCUMENTS INDICATE LOCATION AND RELATIONSHIP OF DEVICES. COORDINATE EXACT LOCATION WITH FURNITURE VENDOR. 21. COORDINATE POWER/DATA, FIRE SAFETY DEVICES & LIGHT FIXTURE MOUNTING LOCATIONS WITH INTERIOR ELEVATIONS, SYSTEM FURNITURE, FINISHES & CASEWORK. 22. PROVIDE EXTENSION RINGS AND MOUNTING ACCESSORIES WHERE REQUIRED FOR POWER/DATA DEVICES AND LIGHT FIXTURES. COORDINATE WITH INTERIOR FINISHES AND CASEWORK. 23. CONTRACTOR TO PROVIDE INSTALLATION DESIGN DOCUMENTS TO ARCHITECT AND BUILDING OWNER FOR REVIEW AND APPROVAL PRIOR TO INSTALLATION. 24. RECIRCUIT, ALTER OR SEPARATE ELECTRICAL AND VOICE SYSTEM AS NECESSARY AND AS DIRECTED BY BUILDING MANAGEMENT FOR ALTERED SUITES. 25. IN AN OPEN CEILING CONDITION ALL ELECTRICAL AND VOICE DATA SHALL BE VISIBLE AND SUITABLE INSTALLATION METHODS SHALL BE USED. 26. LOCATION OF SWITCHES SHALL BE SHOWN ON THE REFLECTED CEILING PLAN. ALL SWITCHES SHALL BE MOUNTED AT A MAXIMUM HEIGHT OF 48" A.F.F. TO MEET THE LATEST ACCESSIBILITY CODES AND REGULATIONS. 27. WHERE MULTIPLE SWITCHES OCCUR IN A SINGLE LOCATION, ALL SWITCHES SHALL BE GANGED UON. 28. WHEN WORKING IN PUBLIC CORRIDOR OR COMMON AREAS VERIFY SWITCHING REQUIREMENTS WITH BUILDING MANAGEMENT. 29. VERIFY WITH BUILDING MANAGEMENT SEPARATION OF SUITE SWITCHING WHEN DEMISING CONFIGURATIONS CHANGE. 30. DOWN LIGHTS SHOWN IN THE CENTER OF CEILING TILE WITHOUT DIMENSIONS ARE TO BE LOCATED IN THE CENTER OF CEILING TILE OR CENTER OF 2X2 PORTION OF 2X4 SECOND LOOK TILE. UON. 31. REUSE ALL EXISTING BUILDING STANDARD FLUORESCENT FIXTURES AS NEEDED PER DESIGN LAYOUT AND TO MEET LOCAL ENERGY CODE COMPLIANCE. VERIFY OR PROVIDE NEW LAMPS AND REPLACE FAULTY BALLASTS. 32. PERMIT DRAWINGS TO BE REVIEWED AND APPROVED IN WRITING BY LANDLORD PRIOR TO COMMENCEMENT OF WORK. 33. ALL OFFICE AREAS LESS THAN 300 SQ. FT. ENCLOSED BY WALLS OR CEILING -HEIGHT PARTITIONS, AND ALL MEETING AND CONFERENCE ROOMS, SHALL BE EQUIPPED WITH OCCUPANCY SENSORS, PER CODE. 34. DESIGN BUILD ELECTRICAL ENGINEERING DRAWINGS INDICATE: A. CIRCUITING AND WIRING OF LIGHT FIXTURES, AND SWITCHES. B. LIFE SAFETY EQUIPMENT. C. LOCATION OF REQUIRED EMERGENCY LIGHT FIXTURES. D. LIGHT FIXTURE SPECIFICATIONS 35. CONTRACTOR TO PROVIDE INSTALLATION DESIGN DOCUMENTS TO ARCHITECT AND BUILDING OWNER FOR REVIEW AND APPROVAL PRIOR TO INSTALLATION. 36. CONTRACTOR SHALL RE -CIRCUIT AND RE -SWITCH ALL ASPECTS OF TENANT SUITE AND ADJOINING SUITES AS NECESSARY TO FULLY SEPARATE TENANT SUITE FROM OTHERS, AND PROVIDE NEW CORRIDOR, HALLWAY AND OPEN OFFICE SWITCHES AS NEEDED. 37. VERIFY SWITCHING WITH TENANT AND BUILDING MANAGEMENT. VERIFY APPROVED ENERGY CODE REQUIREMENTS OR ENERGY MANAGEMENT SYSTEM AS PART OF THE DESIGN BUILD CONTRACT. 38. PROVIDE, ALTER OR VERIFY ALL EMERGENCY EXIT LIGHTING AND ACCESS PATHWAY LIGHTING AS DIRECTED BY EXISTING CONDITIONS AND CODE REQUIREMENTS. 39. EXIT SIGNS SHALL HAVE UL #924. 40. PROJECT MAY HAVE MULTIPLE LIGHT SOURCES AND LAMPS. CONTRACTOR SHALL PROVIDE CONSISTENT LAMPING FOR ALL LIGHT FIXTURE AND BETWEEN FIXTURE TYPES. 3,500K IS PREFERRED. NOTIFY DESIGNER IF CONSISTENT LAMPING IS UNOBTAINABLE AT THE START OF THE PROJECT. 41. VERIFY ALL ENERGY CODE REQUIREMENTS WITH JURISDICTION OF RECORD. VERIFY LIGHT SWITCHING WITH TENANT AND BUILDING MANAGEMENT. 42. PROJECT MAY HAVE LED LIGHTS SPECIFIED. PROVIDE LIGHTING LEVEL ANALYSIS (IN FOOT CANDLES) FOR DESIGNER'S REVIEW BEFORE ORDERING PRODUCT. VERIFY CONTROLS WITH DESIGNER. ALL LED FIXTURES SHALL HAVE DIMMING CAPABILITIES SO THAT AS FIXTURE DIMINISHES THE POWER CAN BE INCREASED SO THAT LIGHTING LEVELS REMAIN CONSTANT AT 70% OVER THE LIFE OF THE FIXTURE (10 YEARS). 43. GC SHALL VERIFY ALL CARD ACCESS AND SECURITY REQUIREMENTS WITH BUILDING MANAGEMENT AND NAW� C R A BUILDING WIDE SYSTEM IS AVAILABLE AT THE START OF THE PROJECT. IF SO AL WORK SHALL BE DO 0 131 E t 4G.0RI Ll�l A 'N C, E BUILDINGS WARRANTEE AND OPERATION IS MAINTAINED. APpROVED NOV 2 2 201 City of Tukwi a BUILDING DIVIS )ION RECEIVED CITY OF TUKWILA OCT 24 2016 Tenant: WESTERN FOODS/CORE GROUP ANDOVER EXECUTIVE PARK BUILDING 13 641 INDUSTRY DRIVE TUKWILA, WA 98188 A Tenant Improvement for: SKB COMPANY ANDOVER EXECUTIVE PARK 617 INDUSTRY DR. TUKWILA, WA 98188 LBI BURGESS I INTERIOR ARCHITECTURE __J _J 1326 Fifth Avenue, Suite 4001 Seattle, WA 98101 T 206 587 7120 W Durgessl?NW.corn All reproduction & intellectual property rights reserved c 2015 Professional seal No. Issue Description Date REVIEW SET 08.15.16 REVISED REVIEW SET 08.23.16 FINAL REVIEW SET 09.12.16 PERMIT SET 09.20.16 CORRECTIONS SET 10.21.16 City Electronic Stamp Location Drawn by: JG/MK Project Project No: 16.3405.00 Manager: RM PROJECT NOTES is 24" x 36". Scale entities accordingly if reduced Idow, G,000 I EGRESS/RESTROOM PLAN 0 83 16' 24 9 1/8 !1$ = 1 11 093 2015 IBC SECTION 1008 MEANS OF EGRESS ILLUMINATION REQUIRED The means of egress serving a room or space shall be illuminated at all times that the room or space is occupied; illumination level shall be not less than 1 footcandle at the walking surface. The power supply for means of egress illumination shall normally be provided by the premises' electrical supply. In the event of power supply failure in rooms and spaces that require two or more means of egress, an emergency electrical system shall automatically illuminate all of the following areas: 1. Aisles, 2. Corridors, 3. Exit access stairways and ramps. In the event of power supply failure in buildings that require two or more means of egress, an emergency electrical system shall automatically illuminate all of the following areas: 1. Interior exit access stairways and ramps. 2. Interior and exterior exit stairways & ramps, 3. Exit passageways, 4. Vestibules at level of discharge, 5. Exterior landings and areas used for exit discharge. EMERGENCY ILLUMINATION FOR BUILDINGS AND DURATION OF ILLUMINATION (1008.3.2--1008.3.5) In the event of power supply failure in Rooms and spaces, an emergency electrical system shall automatically illuminate all of the following areas: 1. Electrical equipment rooms, 2. Fire command centers, 3. Fire pump rooms, 4. Generator rooms, 5. Public restrooms with an area greater than 300 square feet. The emergency power system shall provide power for a duration of not less than 90 minutes and shall consist of storage batteries, unit equipment or an on-site generator. Illumination level under emergency power, the lighting facilities shall be arranged to provide initial illumination that is not less than an average of 1 footcandle and a minimum at any point of 0.1 footcandle measured along the path of egress at floor level. Illumination levels shall be permitted to decline to 0.6 footcandle average and a minimum at any point of 0.06 footcandle at the end of the emergency lighting time duration. A maximum -to -minimum illumination uniformity ratio of 40 to 1 shall not be exceeded. PLUMBING FIXTURES: PER IBC 2902.1 ROOM TYPE/ WATER CLOSET CALC: LAVATORY CALC: DRINKING FOUNTAIN OCC. LOAD I I I CALC: OFFICE (BUSINESS, #2) 1 PER 25 FOR THE FIRST 50 & 1 PER 40 FOR THE FIRST 80 & 1 PER 100 REVISED REVIEW SET 08.23.16 1 PER 50 FOR THE REMAINDER 1 PER 80 FOR THE REMAINDER PERMIT SET 09.20.16 1,618 SQFr/ 100 OCC 16 OCC. 17/2 = 9/25 (MEN) = 0.36 17/2 9/40 (MEN) = 0.25 16/1000 = 0.016 Tenant: 17/2 = 9/25 (WOMEN) = 0.36 17/2 9/40 (WOMEN) = 0.25 WE TERN FOODS/CORE GROUP TRAINING (EDU, #3) 1 PER 50 1 PER 50 1 PER 100 ANDOVER EXECUTIVE PARK BUILDING 13 641 INDUSTRY DRIVE 804 SQFr/ 20 OCC 40/2 = 20/50 (MEN) = 0.4 40/2 = 20/50 (MEN) = 0.4 40/100 = 0.4 TUKWILA, WA 98188 = 40 OCC. 40/2 = 20/50 (WOMEN) = 0.4 40/2 = 20/50 (WOMEN) = 0.4 ASSEMBLY (A3, #1) 1 PER 125 (MEN) 1 PER 200 1 PER 500 1 PER 65 (WOMEN) 378 SQFr/ 15 OCC = 25 OCC. 25/2 = 13/125 (MEN) = 0.1 25/2 = 13/200 (MEN) = 0.065 25/500 = 0.05 25/2 = 13/65 (WOMEN) = 0.2 25/2 = 13/200 (WOMEN) = 0.065 A Tenant Improvement for: KITCHEN (A2, #1) 1 PER 75 1 PER 200 1 PER 500 SKB COMPANY 388 SQFT/ 200 OCC ANDOVER EXECUTIVE PARK 2 OCC. 2/1 = 1/75 (MEN) = 0.013 2/1 = 1/200 (MEN) 0.005 2/500 = 0.004 617 INDUSTRY DR. 2/1 = 1/75 (WOMEN) 0.013 2/1 = 1/200 (WOMEN) = 0.005 TUKWILA, WA 98188 WAREHOUSE 1 PER 100 1 PER 100 1 PER 1,000 (STORAGE, #8) 3/2 = 2/100 (MEN) 0.02 3/2 = 2/100 (MEN) = 0.02 3/1000 = 0.003 DF 2,660 SQFT/ 500 OCC = 3 OCC. 3/2 = 2/100 (WOMEN) = 0.02 3/2 = 2/100 (WOMEN) = 0.02 LB I BURGESS TOTAL COUNT- 1 (MENS), 1 (WOMENS), 1 (MENS), 1 (WOMENS). 1 REQUIRED. 1 ADA/UNISEX PROVIDED 1 ADA/UNISEX PROVIDED 1 PROVIDED INTERIOR ARCHITECTURE 1326 Fifth Avenue, Suite 400 1 Seattle, WA 98101 T 206 587 7120 W BurgessPNW.corn EGRESS LEGEND All reproduction & intellectual property rights reserved c 2015 / / I AREA, NOT IN SCOPE PATH OF EGRESS AT WAREHOUSE, CONCRETE FLOOR TO BE PAINTED WITH STANDARD YELLOW STRIPING MAIN PATH OF EGRESS THROUGH SUITE - - - - - -- I LONGEST PATH OF TRAVEL Professional seal No. Issue Description Date REVIEW SET 08.15.16 REVISED REVIEW SET 08.23.16 FINAL REVIEW SET 09.12.16 PERMIT SET 09.20.16 A CORRECTIONS SET 10.21.16 _VEWM__D_4t_0R_LC CODE COMPLIANCE APPROVED NOV 2 2 2016 City of Tukwila BUILDING DIVISION I Drawn by: JG/MK Project Manager: RM Project No: 16.3405.00 TYPICAL ACCESSIBILITY RECEIVED DIAGRAMS AND NOTES CITY OF TUKWILA OCT 24 2016 PERMIT . CENTER I Original drawing is 24" x 36". Scale entities accordingly if reduced G,02 C3 /02 DEMOLITION PLAN 220,+48 IF I q> 6= 0 89 16' 24 9 z 1/8 is = I 1— 099 0 DEMOLITION SYMBOLS r-= ----3 EXISTING CONSTRUCTION TO BE REMOVED EXISTING CONSTRUCTION TO REMAIN GENERAL DEMOLITION NOTES . 1. REFER TO CONSTRUCTION PLAN AND CEILING PLAN FOR EXTENT OF DEMOLITION. 2. SAVE AND STORE ALL LIGHT FIXTURES, EXIT SIGNS, DOORS & HARDWARE FOR RE—USE, UON. 3. SAVE ALL EXISTING PLUMBING FIXTURES FOR RE—USE, UON. 4. REMOVE ALL TELEPHONE, ELECTRICAL, AND DATA OUTLETS, FIXTURES, PANELS, ETC FROM ALL DEMOLISHED PARTITIONS. REMOVE ALL CORRESPONDING CABLES, CONDUIT, WIRING, ETC. ALL THE WAY BACK TO THE ORIGINATING SOURCE, UON. 5. DEMO ALL FINISHES, FLOORING, WALL PANELS THROUGHOUT SUITE, U.O.N. VERIFY EXTENT OF DEMOLITION AT ADJACENT SUITE WHERE DEMO OCCURS, WITH BUILDING MANAGEMENT. KEYED SHEET NOTES <�> DEMO DOOR, FRAME, AND HARDWARE — TO BE STORED OR RELOCATED AND REINSTALLED WHERE APPLICABLE. VERIFY WITH BUILDING MANAGEMENT. DEMO SIDELIGHT AND FRAME — TO BE STORED OR RELOCATED AND REINSTALLED WHERE APPLICABLE. VERIFY WITH BUILDING MANAGEMENT. DEMO PORTION OF EXISTING PARTITION FOR INSTALLATION OF NEW DOOR/OPENING. REFER TO A.2A.1 AND A.9.1 FOR ADDITIONAL INFORMATION. DEMO EXISTING CASEWORK. PATCH AND REPAIR SURFACES AS REQUIRED FOR NEW CONSTRUCTION AND/OR FINISHES. PROVIDE NEW WALL MOUNTED SINK FIXTURE AND HARDWARE PER ADA/CODE REQUIREMENTS, SEE A.6.1 FOR NEW SPEC. MODIFY WATER AND DRAIN LINES FOR RE—USE. PROVIDE NEW TOILET FIXTURE AND HARDWARE PER ADA/CODE REQUIREMENTS, SEE A.6.1 FOR NEW SPEC. MODIFY WATER AND DRAIN LINES FOR RE—USE. DEMO URINAL, URINAL PANEL AND TOILET STALL AT RESTROOM. PATCH AND PREP REMAINING FINISHES, VERIFY WITH BUILDING MANAGEMENT FOR EXTENT OF REPAIR. DEMO EXISTING CHAIN—LINK FENCE ENCLOSURE AND SUPPORTING MEMBERS. REMOVE LOUVERED GLASS PANELS AT EXTERIOR OF BUILDING (FRONT AND BACK). PROVIDE NEW BUILDING STANDARD SOLID GLASS PANELS AS REQUIRED AT EXISTING OPENINGS. <�> REMOVE SHOWER, HOT WATER TANK AND SINK AT JANITOR ROOM. SEE A.2C.1 FOR NEW EQUIPMENT LOCATIONS. 0 DEMO EXISTING WALL MOUNTED PANELS THROUGHOUT. PATCH AND REPAIR SURFACES AS REQUIRED FOR NEW CONSTRUCTION AND FINISHES. <9> AT EPDXY/RESIN EXISTING FLOORING, SAND OR GRIND DOWN TO APPROPRIATE FLOOR FINISH REQUIRED FOR NEW FLOORING (SEE A.2D.1 FOR NEW BROADLOOM CARPET AND SHEET VINYL). PATCH AND PREP FOR NEW FINISHES. 0 DEMO ALL RESTROOM ACCESSORIES, PROVIDE NEW PER A.6.1. PATCH AND PREP AS NEEDED FOR NEW FINISHES. <q> DEMO EXISTING RESTROOM FLOORING, WALL BASE AND FRP BOARD. ALL FIXTURES AND EQUIPMENT TO REMAIN UNTOUCHED, UON. PATCH AND PREP FOR NEW FINISHES. <@> DEMO EXISTING OUTLET, BOX AND CONDUIT BACK TO J—BOX. <8> REMOVE FRONT ENTRY DOOR. PROVIDE NEW BUILDING STANDARD ENTRY DOOR AND LOCKING HARDWARE TO MEET CURRENT ENERGY CODES. VERIFY WITH BUILDING MANAGEMENT. RECEIVED CITY OF TUKWILA OCT 24 2016 PERMIT CENTER Tenant: WESTERN FOODS/CORE GROUP ANDOVER EXECUTIVE PARK BUILDING 13 641 INDUSTRY DRIVE TUKWILA, WA 98188 A Tenant Improvement for: SKB COMPANY ANDOVER EXECUTIVE PARK 617 INDUSTRY DR. TUKWILA, WA 98188 rW4 I . I R N BURGESS t5INTERIOR ARCHITECTURE L 1326 Fifth Avenue, Suite 400 1 Seattle, WA 98101 T 206 587 7120 W Burgessl`NW.corn All reproduction & intellectual property rights reserved c 2015 Professional seal No. Issue Description Date REVIEW SET 08.15.16 REVISED REVIEW SET 08.23.16 FINAL REVIEW SET 09.12.16 PERMIT SET 09.20.16 CORRECTIONS SET 10.21.16 City E " trnn . ocation 0 FO R REVIEWED FOR IA N CE CODE COMPLIANCE D APPROVED NOV 2 2 2016 City of Tukwila BUILDING DIVISION Drawn by: JG/MK Project Project No: 16.3405.00 Manager: RM DEMOLITION PLAN Original drawing is 24" x 36". Scale entities accordingly if reduced A* 1. 1 *Separate Mechanical Permit shall be required for: Coolers, freezers, walk-in coolers and freezers, i.e. assembled and hardwired. *Self-contained "Plugin99 coolers or freezers (appliance type) shall not require a mechanical permit. SEPARATE STORAGE RACK PERMIT REQUIRED All rack storage fixtures over 5'-911 high shall be installed under the provisions of a separate storage rack building permit. All rack storage fixtures greater than 8 -feet high shall have the method of anchorage/bracing designed by a professional engineer. Periodic special inspection is required in all cases during the anchorage of racks over 8 -feet in height. Special inspection requirements shall be specified on the rack permit plan. SYMBOL LEGEND EXISTING CONSTRUCTION TO REMAIN OMMMEMM NEW INSULATED INTERIOR PARTITION CONSTRUCTION, PER DETAIL K/A.9.1 0 gmmm=m= NEW INTERIOR PARTITION CONSTRUCTION TO STRUCTURE ABOVE, PER DETAIL J/A.9.1 10 NEW INTERIOR PARTITION CONSTRUCTION, MIXED CEILING TYPES, PER DETAIL L/A.9.1 NEW INTERIOR ACOUSTIC PARTITION AT FIRE RATED LOCATION & MIXED CEILING, PER DETAIL M/A.9.4 D NEW INTERIOR PARTITION FILL, PER DETAIL L/A.9.4 NEW INTERIOR PARTIAL HEIGHT CONSTRUCTION (VERIFY FINAL HEIGHT ±6'—O"), PER DETAIL B/A.9.1 FULL HEIGHT SIDELITE PARTIAL HEIGHT SIDEUTE FRAMELESS SIDEUTE NEW CASEWORK / MILLWORK LINE OF UPPER CABINETS F.E.C. NEW OR EXISTING BUILDING STANDARD FIRE EXTINGUISHER CABINET GENERAL CONSTRUCTION NOTES 1. REFER TO PROJECT NOTES FOR CONSTRUCTION REQUIREMENTS. 2. GENERAL CONTRACTOR TO FIELD VERIFY ALL EXISTING CONDITIONS PRIOR TO COMMENCEMENT OF WORK. 3. ALL INTERIOR PARTITION, PENETRATIONS, AND OTHER OPENINGS IN THE BUILDING SHELL SHALL BE SEALED, GASKETED, OR WEATHER STRIPPED AS REQUIRED TO MEET PARTITION RATINGS. 4. WHERE PARTITION LAYOUT INTERSECTS EXISTING SHELL/CORE GYPSUM BOARD, REMOVE EXISTING CORNER BEADS AND OTHER ACCESSORIES, ALIGN FACE OF PARTITIONS, TAPE & SAND SMOOTH FOR NEW FINISH. 5. PROVIDE PARTITION ANCHOR BRACKETS FOR ALL CASEWORK, FIXTURES, EQUIPMENT, & DEVICES MOUNTED ON OR ATTACHED TO PARTITIONS. 6. PARTITIONS ARE TO BE BUILDING STANDARD FLOOR TO CEILING PARTITIONS, UON. SEE TYPICAL WALL DETAIL SHEET FOR MORE INFORMATION. 7. DOORS AND CASED OPENINGS WITHOUT DIMENSIONS OR DETAILS ARE TO BE LOCATED 4" FROM ADJACENT WALL OR MATCH EXISTING SUITE STANDARD. 8. ALL WOOD USED IN INTERIOR FRAMING IS TO BE FIRE—RETARDENT TREATED WOOD WHEN BUILDING IS CONSTRUCTION TYPE I AND 11. 9. REFILL ANY ABANDONED CORE DRILL HOLE OR SIMILAR WITH FIRE PROOFING THAT MATCHES THE FLOOR RATING. LION. 10. VERIFY SCOPE OF NEW CONSTRUCTION AT NIC AREA IN ADJACENT SUITE WHERE DEMOOCCURS. VERIFY WITH BUILDING MANAGEMENT. KEYED SHEET NOTES NEW ADA SINK: PROVIDE ELKAY CELEBRITY SINGLE BOWL SINK, MODEL GECR2521L/R AND MOEN CHATEAU ONE HANDLE KITCHEN FAUCET MODEL #7445, PROVIDE CUT SHEETS FOR REVIEW. NEW TENANT SUPPLIED WALK—IN FREEZER. VERIFY ALL DIMENSIONS AND REQUIREMENTS WITH TENANT. NEW TENANT SUPPUED WALK—IN COOLER. VERIFY ALL DIMENSIONS AND REQUIREMENTS WITH TENANT. <�> PROVIDE ADDITIONAL LAYER OF GWB AT EXISTING WALL FOR ACOUS11C VALUE. <�> FURR PARTMON OR CHANGE STUD WIDTH AS REQUIRED FOR PLUMBING. <�> PATCH AND REPAIR CONCRETE FLOOR AT EXISTING DRAIN. PROVIDE NEW CONTINUOUS, LEVEL AND SMOOTH FLOOR SURFACE. VERIFY WITH BUILDING MANAGEMENT. CENTER WALL ON EXISTING COLUMN. VERIFY DOOR LOCATION BASED ON FREEZER/COOLER SIZES SUPPLIED BY OWNER, PROVIDE 6" CLEAR AT ADJACENT JAMB. PROVIDE NEW BUILDING STANDARD GLAZING AT EXTERIOR WALL WHERE DOOR HAS BEEN REMOVED. NEW GLAZING TO MEET RATINGS OF CURRENT WA STATE ENERGY CODE, PER C402.4. VERIFY WITH BUILDING MANAGEMENT. <@> FURR OUT TO AUGN WITH EXISTING SOFFIT LOCATION. SEE A.28.2 FOR DEI"AlL.S. FIELD VERIFY FINAL DIMENSIONS. VERIFY IF EXISTING HARDWARE IS BUILDING STANDARD LATCH SET. IF NOT PROVIDE NEW TO MATCH SUITE STANDARD. <9> PROVIDE NEW DOORS AND GLAZING AT WAREHOUSE AT EXISTING OPENINGS. NEW DOORS TO MEET RATINGS OF CURRENT WA STATE ENERGY CODE, PER C402.4. VERIFY EXTENT OF SCOPE WITH BUILDING MANAGEMENT, SEE A.9.1 FOR NEW DOOR INFORMATION. PAINTED EXPOSED CONCRETE FLOOR TO BE FREE OF SHELVING, FOR CLEAR PATH OF TRAVEL TO SECONDARY EXIT. SEE A.2131.1 FOR PAINT SPEC AND INFORMATION. <8> GC TO VERIFY IF WALL BETWEEN WAREHOUSE AND OFFICE IS SHEER WALL TYPE. Tenant: WESTERN FOODS/CORE GROUP ANDOVER EXECUTIVE PARK BUILDING 13 641 INDUSTRY DRIVE TUKWILA, WA 98188 A Tenant Improvement for: SKB COMPANY ANDOVER EXECUTIVE PARK 617 INDUSTRY DR. TUKWILA, WA 98188 B —1 BURGESS INTERIOR ARCHITECTURE 1326 Fifth Avenue, Suite 400 1 Seattle, WA 98101 T 206 587 7120 W Burgessi'NW.corn All reproduction & intellectual property rights reserved c 2015 Professional sea] No. Issue Description Date REVIEW SET 08.15.16 REVISED REVIEW SET 08.23.16 FINAL REVIEW SET 09.12.16 PERMIT SET 09.20.16 CORRECTIONS SET 10.21.16 cation REVIEWED FOR CODE COMPLIANCE APPROVtD NOV 2 2 2016 City of Tukwila BUILDING DIVISION Drawn by: JG/MK Project manager: RM Project No: 16.3405.00 CONSTRUCTION PLAN Original drawing is 24" x 36". Scale entities accordingly if reduced A,02A. I I. '40 DEMO REFLECTED CEILING PLAN V2) 0 81 16' 24 9 0 ;b rl 0 A %� V LA RCP LEGEND GENERAL RCP SHEET NOTES 1. REFER TO PROJECT NOTES FOR CONSTRUCTION REQUIREMENTS. 2. ARCHITECTURAL REFLECTED CEILING PLANS INDICATE TYPE AND LOCATION OF LIGHT FIXTURES REFER TO DESIGN BUILD ELECTRICAL DRAWINGS AND DESIGN BUILD LIFE SAFETY FOR COMPLETE REFLECTED CEILING PLAN DESIGN. 3. LIGHT SWITCHES ARE SHOWN FOR LOCATION AND DESIGN INTENT ONLY. REFER TO ELECTRICAL DESIGN BUILD FOR SPECIFIC LOCATION AND SWITCHING DIAGRAMS. 4. UNLESS NOTED OTHERWISE, MULTIPLE SWITCHES IN A SINGLE LOCATION SHALL BE GANGED IN A SINGLE BOX AND COVERED WITH A SINGLE COVERPLATE. 5. CLEAN, REPAIR OR REPLACE AS REQUIRED ALL EXISTING SUSPENDED CEILING GRID AND TILES EXISTING TO REMAIN. 6. HVAC CONTRACTOR TO CLEAN ALL EXISTING SUPPLY/RETURN GRILLS PRIOR TO COMPLETION OF PROJECT. 7. ELECTRICAL SUB -CONTRACTOR IS RESPONSIBLE FOR CONFIRMING THE COUNTS OF EXISTING FIXTURES TO BE RELOCATED. 8. ELECTRICAL SUB -CONTRACTOR IS RESPONSIBLE FOR PROVIDING CUT SHEETS TO DESIGNER FOR ALL FIXTURES DESIGNATED AS NEW. KEYED RCP SHEET NOTES DEMO ALL FULL HEIGHT SOFFITS WHERE NOTED ON PLAN. SEE A.28.2 FOR NEW LOCATIONS. DEMO 2X2 CEILING GRID AND TILES AT CONFERENCE ROOM. PATCH AND REPAIR TO MAINTAIN 2X4 GRID AND TILES. PROVIDE NEW TO MATCH EXISTING. PATCH AND PAINT GRID FOR "LIKE NEW" APPEARANCE. DEMO GWB CEILING AT RESTROOM, PATCH AND PREP REMAINING WALLS AS NEEDED FOR NEW FINISHES. SEE A.28.2 FOR NEW CEILING INFORMATION. Tenant: WESTERN FOODS/CORE GROUP ANDOVER EXECUTIVE PARK BUILDING 13 641 INDUSTRY DRIVE TUKWILA, WA 98188 A Tenant Improvement for: SKB COMPANY ANDOVER EXECUTIVE PARK 617 INDUSTRY DR. TUKWILA, WA 98188 BURGESS INTERIOR ARCHITECTURE 1326 Fifth Avenue, Suite 400 1 Seattle, WA 98101 T 206 587 7120 W BurgessPNW.carn All reproduction & intellectual property rights reserved c 2015 Professional sea] ARCH RANDALL ALAN MORGAN STATE OF WASHINGTOIS No. Issue Description Date REVIEW SET 08.15.16 REVISED REVIEW SET 08.23.16 FINAL REVIEW SET 09.12.16 PERMIT SET 09.20.16 CORRECTIONS SET 10.21.16 CODE COMPLIANCE APPROVED NOV 2 2 2016 City of Tukwila BUILDING DIVISION Drawn by: JG/MK Project Manager: RM Project No: 16.3405.00 DEMO REFLECTED CEILING PLAN RECEIVED CITY OF TUKWILA OCT 24 2016 Original drawing is 24" x 36". Scale entities accordingly if reduced PERMIT CENTER AV r=%A*2t3,1 F.,19210 EXISTING EXIT SIGN TO REMAIN. SYMBOL DESCRIPTION/SPEC COORDINATE WITH CODE OFFICIAL. EXISTING 1' X 4' FLUORESCENT EXISTING EXIT SIGN TO BE SUSPENDED FIXTURE TO REMAIN. REMOVED C_ EXISTING 1' X 4' FLUORESCENT EXISTING 2' X 2' FLUORESCENT FIXTURE TO BE REMOVED. FIXTURE TO REMAIN. EXISTING 2' X 4' FLUORESCENT FIXTURE TO REMAIN. SCONCE TO BE REMOVED r- EXISTING 2' X 4' FLUORESCENT FIXTURE TO BE REMOVED. --k —1— 4- —4 — CEILING GRID AND SOFFITS TO BE REMOVED. GENERAL RCP SHEET NOTES 1. REFER TO PROJECT NOTES FOR CONSTRUCTION REQUIREMENTS. 2. ARCHITECTURAL REFLECTED CEILING PLANS INDICATE TYPE AND LOCATION OF LIGHT FIXTURES REFER TO DESIGN BUILD ELECTRICAL DRAWINGS AND DESIGN BUILD LIFE SAFETY FOR COMPLETE REFLECTED CEILING PLAN DESIGN. 3. LIGHT SWITCHES ARE SHOWN FOR LOCATION AND DESIGN INTENT ONLY. REFER TO ELECTRICAL DESIGN BUILD FOR SPECIFIC LOCATION AND SWITCHING DIAGRAMS. 4. UNLESS NOTED OTHERWISE, MULTIPLE SWITCHES IN A SINGLE LOCATION SHALL BE GANGED IN A SINGLE BOX AND COVERED WITH A SINGLE COVERPLATE. 5. CLEAN, REPAIR OR REPLACE AS REQUIRED ALL EXISTING SUSPENDED CEILING GRID AND TILES EXISTING TO REMAIN. 6. HVAC CONTRACTOR TO CLEAN ALL EXISTING SUPPLY/RETURN GRILLS PRIOR TO COMPLETION OF PROJECT. 7. ELECTRICAL SUB -CONTRACTOR IS RESPONSIBLE FOR CONFIRMING THE COUNTS OF EXISTING FIXTURES TO BE RELOCATED. 8. ELECTRICAL SUB -CONTRACTOR IS RESPONSIBLE FOR PROVIDING CUT SHEETS TO DESIGNER FOR ALL FIXTURES DESIGNATED AS NEW. KEYED RCP SHEET NOTES DEMO ALL FULL HEIGHT SOFFITS WHERE NOTED ON PLAN. SEE A.28.2 FOR NEW LOCATIONS. DEMO 2X2 CEILING GRID AND TILES AT CONFERENCE ROOM. PATCH AND REPAIR TO MAINTAIN 2X4 GRID AND TILES. PROVIDE NEW TO MATCH EXISTING. PATCH AND PAINT GRID FOR "LIKE NEW" APPEARANCE. DEMO GWB CEILING AT RESTROOM, PATCH AND PREP REMAINING WALLS AS NEEDED FOR NEW FINISHES. SEE A.28.2 FOR NEW CEILING INFORMATION. Tenant: WESTERN FOODS/CORE GROUP ANDOVER EXECUTIVE PARK BUILDING 13 641 INDUSTRY DRIVE TUKWILA, WA 98188 A Tenant Improvement for: SKB COMPANY ANDOVER EXECUTIVE PARK 617 INDUSTRY DR. TUKWILA, WA 98188 BURGESS INTERIOR ARCHITECTURE 1326 Fifth Avenue, Suite 400 1 Seattle, WA 98101 T 206 587 7120 W BurgessPNW.carn All reproduction & intellectual property rights reserved c 2015 Professional sea] ARCH RANDALL ALAN MORGAN STATE OF WASHINGTOIS No. Issue Description Date REVIEW SET 08.15.16 REVISED REVIEW SET 08.23.16 FINAL REVIEW SET 09.12.16 PERMIT SET 09.20.16 CORRECTIONS SET 10.21.16 CODE COMPLIANCE APPROVED NOV 2 2 2016 City of Tukwila BUILDING DIVISION Drawn by: JG/MK Project Manager: RM Project No: 16.3405.00 DEMO REFLECTED CEILING PLAN RECEIVED CITY OF TUKWILA OCT 24 2016 Original drawing is 24" x 36". Scale entities accordingly if reduced PERMIT CENTER AV r=%A*2t3,1 F.,19210 REFLECTED CEILING PLAN 0 81 16' 24 9 1/8 111 = 1 9- 093 LIGHTING SUMMARY A D RCP LEGEND 0 Us U 0 M P116nc a V 0 - S to r L a ,Hj,N4 ovei J sto,,e. anda, Project Title: 2015 Washington State EnargyCoda Compliance F- dlngs Including R 2. F1 3. gus L 2 016 project Info Project Title: I - This title will copy onto other forms Date 10/21/2016 liance Applicant Information. Provide contact Information forindividual who can For Building Department Use donot responalto inquiries about compliance form Information provided. For Building Departimen I Use requirea Company Name: Western Foods password to stand alone use. Instructional Company Address: 641 Industry Drive, Tukwila WA - 32 and cat culat'in? o Spaces where <50% of o Spaces vvhere�:50% of cells are write Applicant Name: Julie Glenn/Buirgess Design' protected 12 Applicant Phone: 206�342.0116 luminaires are replaced luminaires are replaced Applicant Ernal: julieg@burgesspnw.com 16 Project Description E] New Building Addition Alteration. El Plans Included I Calculation Include FROJ-SUMfonm (iricludedin envelope forms workbook) with lighting compfliance forms. Building Additions Compliance Method interior lighting Exteriorfighfing Lighting systems in addition area comply W ith all applicable I Referto C406.3for.additionalrequirerrBnts. El 14 Maximum Allowed pro visions as a stand alone.new construction project 20 64 Refer to Section C502.2.6 for additional Lighting systems in addition are combined with existing Ceiling Gross Interior E] requirements. SpaceType building lighting systems todemontrate compliance Wafts per ft2 (w atts/ft2 x area) Suite 641 Addition is combinedwith existing. 13 2547 0.842 2146 For interiorlightingpirojects, include ne.w+existing interior fighting fixture wattage in Proposed Lighting Warehouse: Smaller, hand carried items Wattagetable in LT04NT-BLD orLTG-INT-SPACEform. 0.360 2022 For exterior lightingprojects, include new+ existing extedorlighting fixture mffage in Proposed RestroonT. all other Tradable and Proposed Non- Tradable Lighting Wattage tablesin LTG-EXTform. Interior ard� Exterior Lighting Power Interior lighting Parking garage Exterior lighting Lighting Alterations 50% or more of existing are replaced El Select all LigIting Power and Lighting Retail Display Allowance from LTG -INT -DISPLAY Control elements that applyto the scope Less than 50% of existing are replaced Allowed Watts[ 5564 E] of the retrofitproject. It'project Includes a Lamp and/or ballast replacerne n t only - El combination cfspaceswhere less than 50% of the existingfixtuies areroplacedin exisfing totalwattage not increased El El I somespaces,and 50% ormore ofthe fixtures are replaced in others, then 50% ormore replaced- Total lighting power ofnew + existing-ta-remain fixtures shaNcomplywith total provide separate lighting power LPA per Sections C405.4.2 and C405.5.2. Includ6t hew + existing-to-remainfixturesin Proposed Lijh6ng compliance thrms forthe two retrofit Wattage table in LTG -INT -BLD, LTG-INT-SPACEor LTG-EXTform, conditions. Spaces. undergoi7g the same Less than 50% replaced - Total lighting powerofnew + oxisting4o-remah fixtums, shag not exceadthe type of retrofitmaybe combinedinto one total lighting powerpriorto alteration. Include new+ existing-to-remafn fixtures in the Pr oposedLighting lighting powercomplience form. Wattage table in LTG -INT -BLD, LTG-1NT­SPACEorLTG-EXTform. 50% threshold applies to number ofluminaires; for interiorspaces andparking garages, and total Refer to Section C503. 8 foradditional installed wattage for exterior luminaires. requirements. Lighting Controls Interior lighting Parking garage Exterior lighting Allalteration lightingcontrols shall be commissionedperC408.3. 'New wiring installedto serve added fixtures andforfixtures relocated to new 2 ID circuit(s) :New or moved lighting panel 1:11 El Interior spaceis reconfigured- E] lurninaires unchanged or relocated only New wiring or circuit -For interior lighting, provide required manual controisper C405.2.3, occupancy sensor c ontrolsper C405,2. 1, daylight responsive controls per C405.2.4 and application spedric lighthg �hangesarebeing NO made to controls perC405.2 5. Forexteriorlighting, provide required controls per C405.2.7. the intedororexteriorlighting New or moved panel- Provide all applicable fighting controls as noted forNew Wiring and automatic systems and eidsting space time switch controls per C405.2.2. uses and configurafion are not Reconligured interiorspa ce - Provide all required lighting controls that apply to a new interior space, changed. Applkation specifr li�thtirgcontrolprovlsions per C405.2.5 do not apply to reconfigured spaces. Change.of Space Use E] Ex is fin g interior lighting syste ms. in areas u inder-going A c hange in. s pace u s e are upgraded to corylp ly w ith LPAs for th e new s pace types per Tables C405.4.2(l) or C405.4.2(2). Identifyintertior spac es requiring LPD upgrade to the current Code in Proposed Lighting Wattage tab is in LTG -INT -BLD orLTG4NT-SPACE1hrm. =0 1111% Well My, 1 2 915 W a . hingt. , Slat . E ­ gy C . d. C . . pli. . . . F . to I C - M m .16al 8 tilding. including R 2. F1 3, H 4 3 . t . ri.. -d .11 R I R -i. . d A ug..l. 2 016 Pr oje ct Title: Fill this fine out at top of LGT-SUM I Date 10/21/2016 Interior Lighting System Replacing s u spencled I in ear fixtu res, an d standard 2x4 & 2X2 fixtures th roughou t s u ite. Descriptiont Providing new tas k lighting at training room and hallways, where linear fixtures do not fit with layou L Provide emergencyl ighting to m eet IBC 107;2.3 as requ Ired. See A2B.2 for approximate layout. Brieflydescribe interiarlightirig system type and features. Interior Lighting Power 0 Building Area Method Space -by -space Method Allowance Method Select methodusedin project Interior Lighting Controls 2 AD m5.2.1 - c405.2.8 Controls EJ C405.2 Exception 5 Luminaire Level Lighting Control (LLLC) Additional Efficiency Package Option C406A Enhanced digital lighting controls To complywith C406.4, no less than 90% of the total installed interior lighting powershallcomply with the required controls.per C406.4. 0 Us U 0 M P116nc a V 0 - S to r L a ,Hj,N4 ovei J sto,,e. anda, Project Title: Fill this line out on LGT.SUM Number of Fixtures Date 10/21/2016 Calculation 0 New Construction 0 Addition - 0 Add!tiop clear For Building Departimen I Use Area NOIE 9 stand alone + existing 32 Restroom o Spaces where <50% of o Spaces vvhere�:50% of o �paces where the Use 12 Assembly luminaires are replaced luminaires are replaced is changing (C505) 16 LPA Standard 0 Additional Efficiency Package Option Clear Calculation C406.3 Reduced Interior Lighting Plow er Office Suspended 8'LED Fixture Tocomplywith C406.3, the ProposedLPD shall be25% lowerthan the TargetLPA, 28 IType Referto C406.3for.additionalrequirerrBnts. 1 14 Maximum Allowed Lighting Wattage NOTr; I 20 64 Location (plan #, Ceiling Gross Interior Allowed Watts Allow ed room #) SpaceType Heigh0"' Area in ft2 Wafts per ft2 (w atts/ft2 x area) Suite 641 Office: Open plan 13 2547 0.842 2146 Suite 641 Warehouse: Smaller, hand carried items 13 2660 0.360 2022 Suite 641 RestroonT. all other 8 275 0.780 215: Suite 641 ClassroonrAl ctureltraining 13 118.21 1.000 1182 Total Area Retail Display Allowance from LTG -INT -DISPLAY Lobby Art/Exhibit Display Allowance from LTG -INT -DISPLAY NOTE8 Allowed Watts[ 5564 Proposed Lighting Wattage"cl-I Location (plan 4, room #) Fixture Description NOTE -k 5,6 Number of Fixtures Wells/ FixtureNOTE7 Office/Assem. 2x4 Fluorescent Fixture 24 96 RestfUlso, Recessed Can/Wall Washer 10 32 Restroom Restroomwall mounted Vanity 4 12 Assembly Small Pendant 3 16 Training Alternate Large Pendant 6 32 Office Suspended 8'LED Fixture 20 28 Of fic e Suspended 4'LED Fixture 1 14 Warehouse Suspended 8! Fluorescent Fixture 20 64 Watts 48 i 9-2 T6_0 Proposed Retail Display Lighfing from LTG-INT_DISPLAY Total Proposed Watts maynotexceed TotatAllowed Watts for Interior Lighting Total Proposed Watts 4766 J Interior Lighting Power Allowance COMPLIESI Note I - List all unique space types perTable C405.4.2(2) thatoccur in the project scope. Selectspacetype categoryper from drop down menu. Note 2 - Indicate ceilingheight foratriums and spaces utilizing the ceiling height adjustmentper Table C405.4.2(2), Footnotes dthruf Note 3 - List allproposed lighting fixtures includhg exempt lighting equipment and existing -to -remain fixtures. Note 4 - Forproposed Fixture Description, indicate fixture type, lamp type (e.g. T-8), number oflamps In the fixture, and ballast type (if included). For I tracklioting, list the length of the track (in feet) in addition to the fixture, lamp, and ballastinformaton. Note 5 -For lighiing equipment eligible for exemption per C405.4. 1, note exception numberand leave WattslFixture blank, Note 6 - Existing-to-remairt fixtires shallb e included in the Proposed Lighting Wattage table in the same manner as new fixtures. Identilyas existing in fixture description. Note 7 -Forproposed WattslFixtuia enter the luminairewattage forinstalled lamp andb allast using man utaictureror other approvedsource. For iuminaites Kith scre min lamps, enterthe manufacturer's listedmaximum input wattage of the fixture (not thelamp wattage). Forlow voltage lighting, enterthe mttage of the transformer. Forflne voltagetrack1buswaysystems, enterthelargerofthe attachadiuminaire wattage or5O wattsAireal foot, orenterthe wattage limit ofpermanent current limiting device. Note 8 - Lob byArtlExhibit DisplayAllomnce is independent of the Maximum Allowed Lighting Wattage. Note 9 - Calculation Area Details: ,a. Lighting fixtures in a b Wilding addition maycomply as a stand alone project, or they may b a comb tried Wth the overall existing b uildhig lighting systems to demonstrate compliance. Refer to C502. 1. b. Foratterations andb uilding additicris,. provide Space Types and gross intefiorareas in the Maximum.Allowed Lighting Wattage table. Ifa b uilding addition Will complyas comb.inedwith theoverall existing bulding lighting systems, include all applicable existing Space Types and gross interior areas. c. If less than 50% of existing lighting fixtures will be replaced, provide tot I at existing lighting wattage (prior to alteration), in the space provided in the MaximumAllowedLighting Wattage table. SYMBOL I DESCRIPTION/SPEC NEW BUILDING STANDARD N = NEW. I RESTROOM SCONCE. SPEC: TBD NEW OR RELOCATED 2' X 4' N FLUORESCENT FIXTURE. NEW NEW SWITCH LOCATION. EXISTING 2' X 2' FLUORESCENT N NEW NEW BUILDING STANDARD FIXTURE TO REMAIN. EXHAUST FAN NEW ±19" SUSPENDED PENDANT. NEW GWB SOFFIT. MATCH N =NEW SPEC: LEXINGTON, WHITE, 20"W X EXISTING SOFFIT -10.. .­_... .- -1 - .-- ALL NEW 17' PENDANT (6). N = NEW SPEC: LBL, LOFT GRANDE. BRUSHED ALUM W/POLISHED NEW GWB CEILING. SEE E/A.9.2 NICKEL CAGE. INSTALL AT 8'-0' . . . PAINT P-5, UON. AFF, FIELD VERIFY. NEW SUITE STANDARD ACT GRID AND TILE. MATCH EXISTING HEIGHT AND GRID LAYOUT. PATCH AND PAINT EXISTING GRID FOR "LIKE NEW" APPEARANCE. SEE M/A.9.2 FOR DETAILS. 09=% 00-sts #--% 0-% osease 0�_% A NEW B/S EMERGENCY BUG EYE, IEW EXIT _SIGK WITH ROG Ms - T::7 N NEW FIXTURE PER IBC 1006. N = NEW COORDINATE FINAL LOCATION WITH I>(Ew 7 L CODE OFFICIAL. PER IBC 1006. A 04 A A 04 A 1 04 A A A A -A A li`�C�FE7R -A HE ET NOTES 1. REFER TO PROJECT NOTES FOR CONSTRUCTION REQUIREMENTS. 2. ARCHITECTURAL REFLECTED CEILING PLANS INDICATE TYPE AND LOCATION OF LIGHT FIXTURES REFER TO DESIGN BUILD ELECTRICAL DRAWINGS AND DESIGN BUILD LIFE SAFETY FOR COMPLETE REFLECTED CEILING PLAN DESIGN. 3. LIGHT SWITCHES ARE SHOWN FOR LOCATION AND DESIGN INTENT ONLY. REFER TO ELECTRICAL DESIGN BUILD FOR SPECIFIC LOCATION AND SWITCHING DIAGRAMS. 4. UNLESS NOTED OTHERWISE, MULTIPLE SWITCHES IN A SINGLE LOCATION SHALL BE GANGED IN A SINGLE BOX AND COVERED WITH A SINGLE COVERPLATE. 5. CLEAN, REPAIR OR REPLACE AS REQUIRED ALL EXISTING SUSPENDED CEILING GRID AND TILES EXISTING TO REMAIN. 6. HVAC CONTRACTOR TO CLEAN ALL EXISTING SUPPLY/RETURN GRILLS PRIOR TO COMPLETION OF PROJECT. 7. ELECTRICAL SUB -CONTRACTOR IS RESPONSIBLE FOR CONFIRMING THE COUNTS OF EXISTING FIXTURES TO BE RELOCATED. 8. ELECTRICAL SUB -CONTRACTOR IS RESPONSIBLE FOR PROVIDING CUT SHEETS TO DESIGNER FOR ALL FIXTURES DESIGNATED AS NEW. 9. PROVIDE EGRESS ILLUMINATION PER IBC 1006. CONTRACTOR IS RESPONSIBLE FOR DESIGN OF THIS SYSTEM UNDER THE DESIGN BUILD CONTRACT. VERIFY WITH BUILDING MANAGEMENT'S EXISTING SYSTEM AND PROVIDE FULL COMPLIANCE TO NEW TENANT SPACE. 10. THE MEANS OF EGRESS ILLUMINATION LEVEL SHALL NOT BE LESS THAN 1 FOOT CANDLE (11 LUX) AT THE WALKING SURFACE. KEYED RCP SHEET NOTES TYPE 1 HOOD AT CEILING, SEE POWER PLAN FOR MORE INFORMATION, A.2C.1. CEILING MOUNTED PROJECTOR SCREEN, SEE POWER PLAN FOR MORE INFORMATION, A.2C.1. RELOCATED SUSPENDED LINEAR FIXTURES TO BE INSTALLED AT EXISTING HEIGHT AND REUSE POWER LOCATIONS/LAYOU WHERE POSSIBLE. WHERE CEILING GRID/SOFFIT HAS BEEN REMOVED, CLEAN AND PAINT BOTTOM OF STRUCTURE TO MATCH EXISTING. REPLACE EXISTING EXHAUST FANS WITH NEW BUILDING STANDARD FIXTURES. RE -INSTALL AT EXISTING LOCATIONS. PROVIDE NEW GWB CEILING AT ADA RESTROOM. SEE LEGEND FOR DETAILS. INSTALL PENDANT LIGHTS AS CLOSE TO CEILING GRID AS POSSIBLE - CENTERED IN ROOM. GC. TO COORDINATE FINAL LOCATION/FIELD VERIFY WITH ARCHITECT PRIOR TO INSTALL. Tenant: WESTERN FOODS/CORE GROUP ANDOVER EXECUTIVE PARK BUILDING 13 641 INDUSTRY DRIVE TUKWILA, WA 98188 A Tenant Improvement for: SKB COMPANY ANDOVER EXECUTIVE PARK 617 INDUSTRY DR. TUKWILA, WA 98188 L B BURGESS INTERIOR ARCHITECTURE 1326 Fifth Avenue, Suite 400 1 Seattle, WA 913101 T 206 587 7120 W BurgessloWcom All reproduction & intellectual property rights reserved c 2015 Professional seal RANDALL ALAN MORGAN STATE OF WASHINGTON No. Issue Description Date REVIEW SET 08.15.16 REVISED REVIEW SET 08.23.16 FINAL REVIEW SET 09.12.16 PERMIT SET 09.20.16 A CORRECTIONS SET 10.21.16 City Electronic Stamp Location REVIEWED F OR CODE COMPLIANCE APPROVED NOV 2 2 2016 City of Tukwila Drawn K Project Manager: RM Project No: 16.3405.00 I'VEEFLECTED CEILING PLAN RECEIVED CITY OF TUKWILA OCT.24 2016 Original drawing is 24" x 36". Scale entities accordingly if reduced r PERMIT CENTER 14%, . ei4,-u� ff- ,., A.2 -B.2 EXISTING 1' X 4' FLUORESCENT SUSPENDED FIXTURE TO REMAIN. (D N = NEW NEW BUILDING STANDARD RECESSED WALL WASHER. N = NEW NEW SUSPENDED LED FIXTURE. EXISTING EXIT SIGN TO REMAIN. SPEC: COOPER, NEO -RAY 23 0 COORDINATE WITH CODE DIP. 478' LENGTH OFFICIAL. EXISTING 2' X 4' FLUORESCENT NEW OR RELOCATED EXIT SIGN. FIXTURE TO REMAIN. COORDINATE FINAL LOCATION WITH CODE OFFICIAL. NEW OR RELOCATED 2' X 4' N FLUORESCENT FIXTURE. NEW NEW SWITCH LOCATION. EXISTING 2' X 2' FLUORESCENT N NEW NEW BUILDING STANDARD FIXTURE TO REMAIN. EXHAUST FAN NEW ±19" SUSPENDED PENDANT. NEW GWB SOFFIT. MATCH N =NEW SPEC: LEXINGTON, WHITE, 20"W X EXISTING SOFFIT -10.. .­_... .- -1 - .-- ALL NEW 17' PENDANT (6). N = NEW SPEC: LBL, LOFT GRANDE. BRUSHED ALUM W/POLISHED NEW GWB CEILING. SEE E/A.9.2 NICKEL CAGE. INSTALL AT 8'-0' . . . PAINT P-5, UON. AFF, FIELD VERIFY. NEW SUITE STANDARD ACT GRID AND TILE. MATCH EXISTING HEIGHT AND GRID LAYOUT. PATCH AND PAINT EXISTING GRID FOR "LIKE NEW" APPEARANCE. SEE M/A.9.2 FOR DETAILS. 09=% 00-sts #--% 0-% osease 0�_% A NEW B/S EMERGENCY BUG EYE, IEW EXIT _SIGK WITH ROG Ms - T::7 N NEW FIXTURE PER IBC 1006. N = NEW COORDINATE FINAL LOCATION WITH I>(Ew 7 L CODE OFFICIAL. PER IBC 1006. A 04 A A 04 A 1 04 A A A A -A A li`�C�FE7R -A HE ET NOTES 1. REFER TO PROJECT NOTES FOR CONSTRUCTION REQUIREMENTS. 2. ARCHITECTURAL REFLECTED CEILING PLANS INDICATE TYPE AND LOCATION OF LIGHT FIXTURES REFER TO DESIGN BUILD ELECTRICAL DRAWINGS AND DESIGN BUILD LIFE SAFETY FOR COMPLETE REFLECTED CEILING PLAN DESIGN. 3. LIGHT SWITCHES ARE SHOWN FOR LOCATION AND DESIGN INTENT ONLY. REFER TO ELECTRICAL DESIGN BUILD FOR SPECIFIC LOCATION AND SWITCHING DIAGRAMS. 4. UNLESS NOTED OTHERWISE, MULTIPLE SWITCHES IN A SINGLE LOCATION SHALL BE GANGED IN A SINGLE BOX AND COVERED WITH A SINGLE COVERPLATE. 5. CLEAN, REPAIR OR REPLACE AS REQUIRED ALL EXISTING SUSPENDED CEILING GRID AND TILES EXISTING TO REMAIN. 6. HVAC CONTRACTOR TO CLEAN ALL EXISTING SUPPLY/RETURN GRILLS PRIOR TO COMPLETION OF PROJECT. 7. ELECTRICAL SUB -CONTRACTOR IS RESPONSIBLE FOR CONFIRMING THE COUNTS OF EXISTING FIXTURES TO BE RELOCATED. 8. ELECTRICAL SUB -CONTRACTOR IS RESPONSIBLE FOR PROVIDING CUT SHEETS TO DESIGNER FOR ALL FIXTURES DESIGNATED AS NEW. 9. PROVIDE EGRESS ILLUMINATION PER IBC 1006. CONTRACTOR IS RESPONSIBLE FOR DESIGN OF THIS SYSTEM UNDER THE DESIGN BUILD CONTRACT. VERIFY WITH BUILDING MANAGEMENT'S EXISTING SYSTEM AND PROVIDE FULL COMPLIANCE TO NEW TENANT SPACE. 10. THE MEANS OF EGRESS ILLUMINATION LEVEL SHALL NOT BE LESS THAN 1 FOOT CANDLE (11 LUX) AT THE WALKING SURFACE. KEYED RCP SHEET NOTES TYPE 1 HOOD AT CEILING, SEE POWER PLAN FOR MORE INFORMATION, A.2C.1. CEILING MOUNTED PROJECTOR SCREEN, SEE POWER PLAN FOR MORE INFORMATION, A.2C.1. RELOCATED SUSPENDED LINEAR FIXTURES TO BE INSTALLED AT EXISTING HEIGHT AND REUSE POWER LOCATIONS/LAYOU WHERE POSSIBLE. WHERE CEILING GRID/SOFFIT HAS BEEN REMOVED, CLEAN AND PAINT BOTTOM OF STRUCTURE TO MATCH EXISTING. REPLACE EXISTING EXHAUST FANS WITH NEW BUILDING STANDARD FIXTURES. RE -INSTALL AT EXISTING LOCATIONS. PROVIDE NEW GWB CEILING AT ADA RESTROOM. SEE LEGEND FOR DETAILS. INSTALL PENDANT LIGHTS AS CLOSE TO CEILING GRID AS POSSIBLE - CENTERED IN ROOM. GC. TO COORDINATE FINAL LOCATION/FIELD VERIFY WITH ARCHITECT PRIOR TO INSTALL. Tenant: WESTERN FOODS/CORE GROUP ANDOVER EXECUTIVE PARK BUILDING 13 641 INDUSTRY DRIVE TUKWILA, WA 98188 A Tenant Improvement for: SKB COMPANY ANDOVER EXECUTIVE PARK 617 INDUSTRY DR. TUKWILA, WA 98188 L B BURGESS INTERIOR ARCHITECTURE 1326 Fifth Avenue, Suite 400 1 Seattle, WA 913101 T 206 587 7120 W BurgessloWcom All reproduction & intellectual property rights reserved c 2015 Professional seal RANDALL ALAN MORGAN STATE OF WASHINGTON No. Issue Description Date REVIEW SET 08.15.16 REVISED REVIEW SET 08.23.16 FINAL REVIEW SET 09.12.16 PERMIT SET 09.20.16 A CORRECTIONS SET 10.21.16 City Electronic Stamp Location REVIEWED F OR CODE COMPLIANCE APPROVED NOV 2 2 2016 City of Tukwila Drawn K Project Manager: RM Project No: 16.3405.00 I'VEEFLECTED CEILING PLAN RECEIVED CITY OF TUKWILA OCT.24 2016 Original drawing is 24" x 36". Scale entities accordingly if reduced r PERMIT CENTER 14%, . ei4,-u� ff- ,., A.2 -B.2 KEYED SHEET NOTES WALL MOUNTED DEVICES VERIFY FINAL MOUNTING HEIGHT, LOCATION AND POWER/DATA REQUIREMENTS OF FLATSCREEN WITH SYMBOL DESCRIPTION TENANT. COORDINATE CONNECTIVITIES BETWEEN FLATSCREEN AND CORE DRILL AT CONFERENCE WITH TENANT AND IT PERSONNEL. EXISTING TO REMAIN PROVIDE CEILING MOUNT SPEAKER SYSTEM AT TRAINING ROOM. TENANT TO CONFIRM SCOPE AND FINAL REQUIREMENTS. UTILITY R -3O -SS -1S -D, # DUPLEX OUTLET ( # DENOTES MOUNTING HT IN INCHES) PHONE SYSTEM: COORDINATE POWER, COMMUNICATION, AND BTU OUTPUT WITH TENANT. EXISTING SUITE 2 QUADRAPLEX OUTLET D -MARK FROM PREVIOUS SERVER ROOM, (NOW LOCATED AT VACANT SUITE). VERIFY WITH BUILDING F -3O -SS -1S -D 84"HX34"DX30'V MANAGEMENT. N/A Fil DEDICATED DUPLEX OUTLET TENANT PROVIDED SHELVING AT WAREHOUSE - UNDER 12', NO WALL/CLNG SUPPORT IS REQUIRED. PROVIDE EXTRA 208V POWER LOCATION, FOR FUTURE USE. VERIFY FINAL LOCATION WITH TENANT. 44-4 78"HX44"DX35"W NEMA 12 CONTROL PANEL 2, J" HW COPPER WATER LINES 11- DRAIN LINE DEDICATED QUADRAPLEX OUTLET 1 3 COMPARTMENT SINK (VERIFY FINAL SPEC W/TENANT) VOICE & DATA COMBINATION OUTLET. (MUD RING AND PULL STRING 93-23-60-18RL lO3'X2O'X37" - VERIFY EXTENT OF WHAT IS PROVIDED WITH BUILDING MANAGEMENT) ALTERNATE PRICING 1-6 SPECIALTY OUTLET PROVIDE CORE DRILL AT TRAINING ROOM ISLAND/TABLE. VERIFY FINAL LOCATION AND REQUIREMENTS WITH TENANT/IT PERSONNEL 1 PROVIDE JUNCTION BOX IN WALL FOR TENANT SUPPLIED FURNITURE WHIP. VERIFY BEST LOCATION. VERIFY POWER/DATA REQUIREMENTS FOR EA. WORKSTATION WITH TENANT AND FURNITURE SUPPLIER. FLOOR MOUNTED DEVICES. F -P30-18 40"HX40"DX20'V 120V, 1 PHASE, 3 AMPS FLUSH FLOOR MOUNTED COMBINATION VOICE & DATA OUTLET AND DUPLEX OUTLET - COORDINATE EXACT LOCATION WITH TENANTS FURNITURE VENDOR. 1 MISC. NOTATION POWER AND DATA PLAR 0 81 16' 24 1/8 99 = 1 11 099 N I DENOTES A NEW DEVICE GFI I DENOTES A GROUND FAULT INTERRUPT CIRCUIT GENERAL ELECTRICAL NOTES 1. REFER TO PROJECT NOTES FOR CONSTRUCTION REQUIREMENTS. 2. ELECTRICAL SUB -CONTRACTOR IS RESPONSIBLE FOR VERIFYING THE WORKING CONDITION OF ALL EXISTING OUTLETS NOTED TO REMAIN. G.C. TO REPAIR OUTLETS IF FAULTY, VERIFY WITH BUILDING MANAGEMENT FOR LOCATIONS. 3. ALL OUTLETS SHOWN ARE APPROXIMATE. DUE TO HIDDEN CONDITIONS ADDITIONAL P/P/D MAY EXIST BUT NOT BE REFLECTED ON THE PLANS. 4. FURNITURE SHOWN FOR INTENT ONLY, FINAL LOCATION OF FURNITURE AND OUTLETS TO BE COORDINATED WITH TENANTS FURNITURE VENDOR. VERIFY ELECTRICAL AND VOICE/DATA REQUIREMENTS WITH TENANT. 5. UNLESS DIRECTED OTHERWISE, ALL VOICE/DATA CABLING AND EQUIPMENT ASSOCIATED WITH VOICE/DATA SERVICE INCLUDING WORK FROM BUILDING/FLOOR D -MARK TO SERVER ROOM SHALL BE FURNISHED AND INSTALLED BY TENANT. G.C. TO VERIFY WITH BUILDING MANAGEMENT FOR FINAL PROJECT SCOPE. 6. FURNITURE VENDOR TO VERIFY ALL POWER AND DATA LOCATIONS AND HOW THEY INTERFACE WITH FURNITURE. VENDOR TO VERIFY ALL CRITICAL DIMENSIONS. G.C. TO COORDINATE VENDOR'S FIELD VERIFICATION OF ALL FURNITURE DIMENSIONS. EQUIPMENT LIST - VERIFY ALL REQUIREMENTS FOR TENANT PROVIDED EQUIPMENT, G.C. TO PROVIDE ACCESSORIES, LION. # EQUIPMENT MANUFACTURER MODEL # DIMENSIONS POWER INFORMATION PLUMBING. REQUIREMENTS NOTES 1 AASHER/DRYER COMBO ±28"DX30"W DEDICATED 120V WATER LINE REQ. VERIFY HEIGHT CLEARANCE REQ. L2 J I I 2 REACH -IN REFRIGERATOR, 1 DOOR UTILITY R -3O -SS -1S -D, 84'HX34"DX30'V 5-15 NEMA PLUG N/A 2 REACH -IN FREEZER, 1 DOOR UTILITY F -3O -SS -1S -D 84"HX34"DX30'V 5-15 NEMA PLUG N/A Fil 1 SINGLE TANK CONVEYOR DISHWASHER INSINGER ADMIRAL 44-4 78"HX44"DX35"W NEMA 12 CONTROL PANEL 2, J" HW COPPER WATER LINES 11- DRAIN LINE Fil 1 3 COMPARTMENT SINK (VERIFY FINAL SPEC W/TENANT) ADVANCE TABCO 93-23-60-18RL lO3'X2O'X37" N/A CW A" HW I" DRAIN. DIRECT CONNECT W/GREASE INTERCEPTION FAUCETS NOT INCLUDED VERIFY GC TO FURNISH AND INSTALL F71 1 GAS FRYER I ULTRA FRYER SYSTEMS F -P30-18 40"HX40"DX20'V 120V, 1 PHASE, 3 AMPS 7" WATER COLUMN NATURAL GAS & 14" WATER COLUMN PROP./BUTANE 1 GAS CHARBROILER, 12" TOP ELECROLUX EM SERIES 169020-AGG12 18"HX32"DX12"W N/A NPT, NATURAL GAS & PROPANE INCLUDES ELECTROLUX OPEN CUPBOARD 169028-AV12 AT BASE. Fil 1 GAS RANGE/OVEN, 4 BURNER W/ STATIC 24- OVEN ELECROLUX EM SERIES 169004-ACFG24 38"HX32"DX24V N/A NPT, NATURAL GAS & PROPANE Fi-ol 1 CONVECTION OVEN/ ELECTIC COMBI OVEN ELECTROLUX, AIR -O -STREAM 257281 - AOSO62ETM1 42"HX45"DX49"W 208V, 3PH, 58 AMPS, CIRCUIT BREAKER WATER LINE & 14" DRAIN 1 TYPE I HOOD TBD 5'WX1 'I'L N/A PROVIDE APPROVED FIRE SUPPRESSION SYSTEM 1 FOOD PROCESSOR, TRS ELECTROLUX 603355-TRS22 20"HX20"DX9'V 115V, 1PH N/A ri-31 1 SANDWICH PRESS ELECTROLUX 603859-HSPPAl 25"HX27"DX14"W 208V, 1 PH, 26 AMPS, NEMA6-30 PLUG N/A INSTALL 7" FROM WALL & 2" BETWEEN OTHER UNITS. 1 PANINI PRESS ELECTROLUX 602104-DGR15U 9"HX18"DX15"W 120V, 1 PH N/A F1 5] 1 PREFAB WALK-IN FREEZER 24'-l"L X 14'-6"W 12'-0" CEILINGS, BUILT-IN FLOOR AT FREEZER 1 PREFAB WALK-IN FREEZER 24'-l"L X 14'-6"W 12'-0" CEILINGS, BUILT-IN FLOOR AT FREEZER F171 1 PREFAB WALK-IN COOLER 24'-l"L X 1O'_1O"W 12'-0" CEILINGS, INSTALLED ON GRADE CONCRETE FLOOR. El 1 HAND WASHING SINK ADVANCETABCO 7 -PS -54 17"X15"X13" N/A CW J" HW DRAIN MINIMUM HOT WATER TEMP ALLOWED 100* * VERIFY GC TO FURNISH AND INSTALL Fl -91 1 PREP SINK ADVANCE TABCO 93-21-20-18R/L 44-X2O'X37" N/A CW I" HW --J" DRAIN INDIRECT WASTE DRAIN LINE * VERIFY GC TO FURNISH AND INSTALL 1 COFFEE MAKER N/A 1 COPIER/PRINTER DEDICATED P/V/D N/A 1 FLATSCREEN TELEVISION N/A PROVIDE BACKING AT NEW/EXISTING WALLS. 1 MINI FRIDGE 1 PAPER TOWEL DISPENSER BOBRICK B-262 OR SIM. 11 "X4"X 15" N/A N/A INSTALL 48" AFF MAX PER ADA REQ. * VERIFY GC TO FURNISH AND INSTALL 1 HAND SOAP DISPENSER BOBRICK 818615 OR SIM. 7"X6"X4" N/A N/A * VERIFY GC TO FURNISH AND INSTALL 1 SINGLE PHASE HOT WATER HEATER CEILING MOUNTED G.E. B/S 47"X20" DIA. CAPACITY (40GAL -VERIFY WITH TENANT) * GC TO PROVIDE FF1 MICROWAVE GROUNDED DUPLEX N/A I Tenant: WESTERN FOODS/CORE GROUP ANDOVER EXECUTIVE PARK BUILDING 13 641 INDUSTRY DRIVE TUKWILA, WA 98188 A Tenant Improvement for: SKB COMPANY ANDOVER EXECUTIVE PARK 617 INDUSTRY DR. TUKWILA, WA 98188 BURGESS INTERIOR ARCHITECTURE 1326 Fifth Avenue, Suite 400 1 Seattle, WA 98101 T 206 587 7120 W BurgessPNW.corn All reproduction & intellectual property rights reserved c 2015 Professional seal LL ALAN MORGAN OF WASHINGTON No. Issue Description Date REVIEW SET 08.15.16 REVISED REVIEW SET 08.23.16 FINAL REVIEW SET 09.12.16 PERMIT SET 09.20.16 CORRECTIONS SET 10.21.16 City Electronic Stamp ockEVIEWED FOR CODE COMPLIANCE APPROVtD RECEIVED 2 2 2016 CITY OF TUKWILA OCT 24 2016 city of Tukwila BUILDIN(G DIVISION L PERMIT CENTER, Drown by: JG/MK Project Manager: RM Project No: 16.3405.00 POWER-& DATA PLAN Original drawing is 24" x 36". Scale entities accordingly if reduced f - *nA. 2 C, I KEYED SHEET NOTES NEW EXIT PATHWAY FLOOR PAINT, P-8. PAINT TO BE 'WARNING' YELLOW. VERIFY WITH CITY OF TUKWILA. IN EXISTING WAREHOUSE AREA, CLEAN, GRIND AND SEAL EXISTING CONCRETE FLOOR. PROVIDE 42"H P -LAM WET WALL LOCATIONS AT TENANT RESTROOMS (3). USE ONE OF EXISTING TENANT P -LAM SPECS, FINAL SELECTION: PL -3. FINISH SPECIFICATIONS SYMBOL I MANUFACTURER I DESCRIPTION BASE 4"h COVED RUBBER BASE. *NOT USED AT SV -1 LOCATIONS FB -11 ROPPE COLOR: CHARCOAL 123 ALTERNATE PRICING CARPET PROVIDE 42"H SUBWAY TILE AT WET WALL LOCATIONS AT TENANT RESTROOMS (3). E�] J&J INVISION FIELD CARPET STYLE: STRUCTURE 2010, COLOR: TRUSS 1804 Efl DUNN EDWARDS GWB SEMI -GLOSS FINISH - ACCENT COLOR @ RESTROOMS INSTALLED: DIRECT GLUE, INSTALL PATT: DIRECT GLUE PAINT COLOR: LIME SORBET DE 5550 F -P-11 BENJAMIN MOORE GWB EGGSHELL FINISH COLOR: DECORATORS WHITE CC -20 ED DUNN EDWARDS GWB EGGSHELL FINISH - ACCENT COLOR COLOR: LIME SORBET DE 5550 BENJAMIN MOORE Efl DUNN EDWARDS GWB EGGSHELL FINISH - ACCENT COLOR COLOR: PURPLE TRINKET DE 5979 SPEC: STANDARD NEON EXIT STRIPING COLOR BENJAMIN MOORE WOOD DOOR/FRAME SEMI -GLOSS FINISH COLOR: CHELSEA GRAY HC -168 EXISTING CONCR I ___TBENJAMIN BENJAMIN MOORE GWB FLAT FINISH - SOFFIT/CEILING COLOR COLOR: DECORATORS WHITE CC -20 VERIFY IF SEALING FLOOR IS REQUIRED. P7 F -6 MOORE GWB SEMI -GLOSS FINISH - FIELD COLOR @ RESTROOMS AND FOOD PREP COLOR: DECORATORS WHITE CC -20 FINISH FLOOR PLAN 0 89 16' 24 9 1/8 19 = i I- oil E�] BENJAMIN MOORE GWB SEMI -GLOSS FINISH - ACCENT COLOR @ RESTROOMS AND FOOD PREP COLOR: CHELSEA GRAY HC -168 Efl DUNN EDWARDS GWB SEMI -GLOSS FINISH - ACCENT COLOR @ RESTROOMS COLOR: LIME SORBET DE 5550 DUNN EDWARDS GWB SEMI -GLOSS FINISH - ACCENT COLOR @ RESTROOMS COLOR: PURPLE TRINKET DE 5979 I _P_ 101 BENJAMIN MOORE WAREHOUSE EXIT PATH @ CONCRETE FLOOR SPEC: STANDARD NEON EXIT STRIPING COLOR EXPOSED CONCRETE EK EXISTING CONCR I GRIND AND CLEAN EXISTING CONCRETE FLOOR AT WAREHOUSE AREA. VERIFY IF SEALING FLOOR IS REQUIRED. SHEET VINYL FLOORING MANNINGTON 6' WIDE SHEET VINYL W/6- INTEGRAL COVE BASE (WELDED SEAMS) & METAL TRIM. TRANSITION STRIP: J" SCHLUTER STRIP. STYLE: BIOSPEC FINE FIELDS, COLOR: IRON 10368 PLASTIC LAMINATE FPL -71 FORMICA PLASTIC LAMINATE HORIZONTAL SURFACES/BACKSPLASH. LAMINATE COLOR: BASALT SLATE 3690-77 FP—L-2] FORMICA PLASTIC LAMINATE VERTICAL SURFACES LAMINATE COLOR: BURNT STRAND 6307-58 INTERIOR MELAMINE COLOR: WHITE FP L —73 FORMICA PLASTIC LAMINATE VERTICAL SURFACES/WAINSCOTTING *RESTROOM WET WALLS LAMINATE COLOR: DOVER WHITE 7197-58 WALL COVERING Fw-c _-11 WOLF GORDON WALL COVERING @ RECEPTION - PROVIDE LEVEL 5 FINISH AT WALL. SPEC: BONAIRE, COLOR: ONYX, WITH PRODUCT BNR 7-3266 WALL COVERING @ CONFERENCE - PROVIDE LEVEL 5 FINISH AT WALL. FWC--2] WOLF GORDON SPEC: BONAIRE, COLOR: MOON, WITH PRODUCT BNR 7-3258 CERAMIC TILE -ALTERNATE OPTION DALTILE SUBWAY TILE AT WET WALL LOCATIONS, 42- AFF 1/METAL TRANSITION STRIP. FCT _1 I SPEC: MODERN DIMENSIONS, ARCTIC WHITE - VERIFY FINAL SIZE. ENERAL FINISH NOTES 1 . PROVIDE B-1 THROUGHOUT, UON. 2. PROVIDE P-1 THROUGHOUT, LION. 3. PROVIDE CPT -1 THROUGHOUT, UON. 4. REFER TO ELEVATIONS AND DETAIL SHEETS. 5. CENTER TRANSITION BETWEEN MATERIALS UNDER DOOR PER DETAILS. 6. ALL WOOD VENEER SHALL COME FROM THE SAME FLITCH AND SEQUENCE, LION. (IF APPUCABLE) RECEIVED CITY OF TUKWILA OCT 24 2016 CENTER Tenant: WESTERN FOODS/CORE GROUP ANDOVER EXECUTIVE PARK BUILDING 13 641 INDUSTRY DRIVE TUKWILA, WA 98188 A Tenant Improvement for: SKB COMPANY ANDOVER EXECUTIVE PARK 617 INDUSTRY DR. TUKWILA, WA 98188 NE -Z BURGESS Lolp INTERIOR ARCHITECTURE 1326 Fifth Avenue, Suite 400 1 Seattle,. WA 98101 T206 587 7120 W BurgessPNW.corn All reproduction & intellectual property rights reserved c 2015 Professional seal LL ALAN MORGAN OF WASHINGTON No. Issue Description Date REVIEW SET 08.15.16 REVISED REVIEW SET 08.23.16 FINAL REVIEW SET 09.12.16 PERMIT SET 09.20.16 CORRECTIONS SET 10.21.16 City Electronic Sto REVIE D FOR CODE COMPLIANCE APPROVED Nov 2 2 2016 City of Tukwila E ILDING DIVISION , 7)UT Drawn by: JG/MK Project Manager: RM Project No: 16.3405.00 FINISH FLOOR PLAN Original drawing is 24" x 36". Scale entities accordingly if reduced % .1 30"x48" PLFJV�_ AR EA FOR ADA ACCESS 1 L - 19/1 b 0 qO x6 Ac CL�OR REA F_� FOR TOIL �CCESSIBILITY L_qA —60 - ADA �j _,V, 0 J_ ENLARGED RESTROOM PLAN 54" MIN. 39"-41" 42" MIN. 1- 1 /4"Ox421 GRAB BAR - 12" - MAXt W.0 co CD _Q0 C) 0 C*_J I I— oil 3/8 FWALL -MOUNTED LIGHT FIXTURE, WHERE OCCURS I J 24'00" SELF FRAMED F-1 MIRROR CD T > A LAV. -;d- 0 in NON HC ACCESSIBLE URINAL TYP. ADA COMPLIANT RR MOUNT. HTS. NTS RESTROOM ACCESSORY PLAN t�E CD 1 I LLJ 0-1 V) FIXTURE VERIFY WITH BUILDING MANAGEMENT. 0 0 DISPENSER NON -ADA TOILET UNIT 0-) PAPER TOWEL NON HC ACCESSIBLE W.C. 1 - 1 /2"0061 GRAB BAR > LLJ C/� 1-1� LJ_ 0 a- 0 0 = C) < r, - I =: X < 0 LC) CD L0 _C*�l C -,,J 99 V 3/8 2f: SOAP DISP X < HC 8" MIN---� 6" MAX ACCESSIBLE 'TOE CLEARANCE W.C. V-51' MIN DItPTH MIRROR WIT CHROME ED PIECE ADA COMPLI SINK & FAIL 0 TYP. ADA SINK ELEVATIONS LJ__LJ_L______F_____1 0 4 8 113 12 99 Reach portion of fixture can't be 5" MAX. ter than 48" off. Seat dispenser can NO LONGER go behind BUBBLER toilet in ADA. _-S < X C� , I < < :z CD CD X CD CD < T 00< rr) ;z U) C__,l NAPKIN EXCEPT GRAB BARS. 1 PAPER DISPOSAL FIXTURE VERIFY WITH BUILDING MANAGEMENT. TOWEL UNIT DISPENSER NON -ADA TOILET UNIT PAPER DISPENSER PAPER TOWEL DISPOSAL UNIT J AFF. 3/8 1 11 011 ALL ACCESSORIES ARE FROM CONTURA LINE OF BOBRICK PRODUCTS ACCESSORIES EXCEPT GRAB BARS. USE THESE SPECS FOR BIDDING AND IN LIEU OF BUILDING STANDARDS. SYMBOL FIXTURE VERIFY WITH BUILDING MANAGEMENT. WALL—MOUNTED SOAP DISPENSER — REUSE EXISTING WHERE POSSIBLE BOBRICK B-818615, STAINLESS STEEL FINISH (OR APPROVED EQUAL) SURFACE—MOUNTED TOILET SEAT COVER DISPENSER — REUSE EXISTING WHERE POSSIBLE BOBRICK B-4221 (OR APPROVED EQUAL) SURFACE—MOUNTED MULTI—ROLL TOILET TISSUE DISPENSER — REUSE EXISTING WHERE POSSIBLE B-4288 (OR APPROVED EQUAL) SURFACE—MOUNTED SANITARY NAPKIN WASTE RECEPTACLE — REUSE EXISTING WHERE POSSIBLE BOBRICK B-270 (OR APPROVED EQUAL) RECESSED PAPER TOWEL DISPENSER — REUSE EXISTING WHERE POSSIBLE BOBRICK B-4369 (OR APPROVED EQUAL) GRAB BAR @ 36 X 1 1/2" — REUSE EXISTING WHERE POSSIBLE BOBRICK 6806 SERIES (OR APPROVED EQUAL) GRAB BAR @ 42- X 1 1/2- — REUSE EXISTING WHERE POSSIBLE) BOBRICK B-6806 SERIES (OR APPROVED EQUAL) VERTICAL GRAB BAR @ 18" X 1 1/2" - REUSE EXISTING WHERE POSSIBLE BOBRICK B-6806 SERIES (OR APPROVED EQUAL) EQUIPMENT SYMBOL FIXTURE <� NEW ADA—COMPLIANT TOILET. SPEC: KOHLER ADAIR K 3946 (OR APPROVED EQUAL). VERIFY FLUSHING METHOD WITH BLDG MGMT. <� NEW ADA COMPLIANT WALL MOUNTED LAVATORY. SPEC: KOHLER, GREENWICH WALL—MOUNT (OR APPROVED EQUAL). NEW ADA—COMPLIANT LAVATORY MANUAL FAUCET. VERIFY WITH BUILDING MANAGEMENT FOR B/S SPEC. VERIFY AERATOR WITH BUILDING MANAGEMENT. GENERAL NOTES 1. ALL RESTROOM FLOORS SHALL BE IMPERVIOUS SURFACES AND HAVE 4" INTEGRAL COVED BASE. 2. ALL RESTROOM WET WALLS SHALL HAVE AN IMPERVIOUS SURFACE UP TO 48" MIN A.F.F. 3. P—TRAP INSULATION COLORS ARE WHITE. 4. ALL PLUMBING FIXTURES ARE WHITE. 5. ALL FAUCETS AND BRIGHT WORK ARE POLISHED CHROME — VERIFY WITH BUILDING MANAGEMENT. 6. VERIFY INSTALLATION REQUIREMENTS OF SURFACE MOUNT VERSUS RECESSED ACCESSORIES WITH ROOM CONDITIONS. FURR PAR11TIONS AS NECESSARY. 7. VERIFY SCREW LENGTH FOR CONNECTION OF ACCESSORIES INTO P—LAM PARTITIONS SO NO SCREWS ARE EXPOSED. 8. ALL GRAB BARS SHALL SUPPORT A MINIMUM OF 250LBS PER ANSI 609.8 9. PROVIDE ALL RESTROOM SIGNAGE PER IBC 1110.1.3. 10. VERIFY WATERPROOFING WITH BUILDING MANAGEMENT. 42" ol MAX. 36" MAX. - 15" MIN. 24" MIN. X < C1.11 EWC FIRE EXTINGUISHER CABINET 42" MAX. 36" MAX. 24" MIN. - C"'I RECEIVED CITY OF TUKWILA OCT 24 2016 RMIT CENTER PE 01A X X < < _00 _00 00 00 - . 11, " - RECESSED TOILET PAPER DISPENSER A) PROTRUDING TOILET PAPER DISPENSER BELOW GRAB BAR B) PROTRUDING TOILET PAPER DISPENSER ABOVE GRAB BAR Tenant: WESTERN FOODS/CORE GROUP ANDOVER EXECUTIVE PARK BUILDING 13 641 INDUSTRY DRIVE TUKWILA, WA 98188 A Tenant Improvement for: SKB COMPANY ANDOVER EXECUTIVE PARK 617 INDUSTRY DR. TUKWILA, WA 98188 BURGESS B INTERIOR ARCHITECTURE ___J I 1326 Fifth Avenue, Suite 400 1 Seattle, WA 98101 T 206 587 7120 W Burgessi'Mcorn All reproduction & intellectual property rights reserved c 2015 Professional seal No. Issue Description Date REVIEW SET 08.15.16 REVISED REVIEW SET 08.23.16 FINAL REVIEW SET 09.12.16 PERMIT SET 09.20.16 CORRECTIONS SET 10.21.16 City Electro j, i : 0 9 1 �F LCity of Tukwila BUILDING DIVISION Drawn by: JG/MK Project Manager: RM Project No: 16.3405.00 ADA UNISEX RESTROOM Original drawing is 24" x 36". Scale entities accordingly if reduced c DEVICES SHOWN STACKED IN PLAN ARE TO ALIGN VERT. AS SHOWN BELOW 0 0 AT LOCATION AS DIMENSIONED ON SOLID WOOD TOP W/ EASED PLAN; OR NEXT TO DOOR / 1, EDGES. OPENING AS DIMENSIONED BELOW SPM VUSY F PMM OR STAWD WOOD El 0 0] 6" e FIRE ALARM STROBE 1/4" QUIRK PAINT BLACK _J 9 it _ FRAME WHERE OCCURS J—BEAD — FINISH AND PAINT ROOM SIGNAGE, ETC. TO MATCH WALL COLOR. P= THERMOSTAT, IF CONTROLLER 5/8" TYPE "X" GYP PARTITION TYPE PLAN U) METAL STUDS / INTERMEDIATE SUPPORT AS SCHEDULED LIGHT & PROJECTION SCREEN —0" O.C. 6 SWITCHES, WALL MOUNTED C) AT END OF WALL & 8' L'J OCCUPANCY SENSOR < Of 2 1/2' X 2 1/2 X 3/16" CARD READER WHERE OCCURS HARDWARE LATCH TELEPHONE OUTLET FINISHED FLOOR ELECTRICAL OUTLET 1. LOCATE SWITCHPLATES, ELECTRICAL AND TELEPHONE WALL OUTLETS AT NEAREST STUD FROM SCALED LOCATION ON PLAN, UNI ESS SPECIFICALLY DIMENSIONED ON PLAN, ELEVATION, OR LOCATION AS PER DIAGRAM ABOVE. 2. CENTER FIRE ALARM STROBES DIRECTLY ABOVE FIRE EXTINGUISHER CABINETS WHERE BOTH OCCUR. 3. DETAIL IS SCHEMATIC IN NATURE AND ADA COMPLIANCE MAY BE ACHIEVED WITHIN A RANGE. VERIFY WITH ARCHITECT IF QUESTIONS. 4. IN AREAS WHERE ACCESS FLOOR HAS BEEN REMOVED; VERIFY WITH BUILDING MANAGEMENT AND TENANT WHETHER DEVICES SHOULD BE ALTERED TO STANDARD HEIGHTS. LIGHT SWITCHES MUST BE LOWERED TO ADA COMPLIANT HEIGHTS. GENERAL DEVICE ALIGNMENT 1/4" M OF STRUCTURE qT i GWB TO METAL STUDS LEG TOP TRACK .R DRIVEN FASTENER @ 24"0C CEILING AS SCHEDULED 1 THICKNESS MAY VARY — NDARD VS. 6". SEE PLANS FOR ATIONS. ADJUST WALL ACCORDINGLY. 3 5/8' X 20 GA. (33 MILS) METAL STUDS STUDS @ 24" OC, TO 14'-9" MAX. HEIGHT INSULATION LION ON PLANS POWDER DRIVEN FASTENER @ 24"oc MET RUNNER TRACK SEALANT CONCRETE SLAB NTS LOW PARTITION W/ WOOD CAP RAIL 0 19 4 39 8 of 12 is 1/4" BOTTOM OF STRUCTURE PROVIDE ENCAPSULATED ACOUSTICAL BATT EXTENDING 24" EACH SIDE OF PARTITION. 011 = I — 11 3 1 0 2"X2"X12" MIN. LEG AT STRUCTURE — ATTACH W/2 POWDER DRIVEN FASTENERS PER BRACE OR OTHER APPROVED METHOD PLENUM HEIGHT OF 5'-0" OR LESS 2 1/2"x25 CA METAL STUD BRACING @ 8'-0" OC TO STRUCTURE DIRECTION ALTERNATE. PARTITIONS PERPENDICULAR TO PARTITION ACT AS BRACE PLENUM OF 5'-0" TO 10'-0" SHALL USE NESTED OR BACK TO BACK 3-1/2" 25 GA. STEEL STUDS. ABOVE 10'-0" OR PLENUM. CONTACT ARCHITECT FOR ADDITIONAL INFORMATION. MAX PARTITION WEIGHT 15lbs./P.S.F. SUSPENDED CEILING AS SCHEDULED VERIFY B/S HEAD CONDITION 3/8' CONT. FOAM SOUND ISOLATION TAPE TAPEABLE MET. TOP TRACK ATTACHED TO BRACING W/2 SELF—TAPPING SM. SCREWS @ 48"oc, AND 3/4" PIPE SLEEVES PROVIDE BATT INSULATION IN CAVITY. WALL THICKNESS MAY VARY — STANDARD VS. 6". SEE PUNS FOR LOCATIONS. ADJUST WALL ACCORDINGLY. 2 1/2' X 25 CA (18 MILS) METAL STUDS @ 24" OC, TO 10'-7" MAX. HEIGHT. 1 LAYER 5/8' TYPE 'X' GYP. BD. EA. SIDE OF METAL STUDS ATTACHED W/ #6SCREWS @ 12' O.C. MAX. POWDER DRIVEN FASTENER @ 24" OC MET. RUNNER TRACK SEALANT CONCRETE SLAB --,,�PARTIAL HT. PARTITION SUPPORT POST 1 1 EXPOSED CEILING SIDE 1/4" L 1/2' BOTTOM OF STRUCTURE SEALANT ATTACH GWB TO METAL STUDS NTS LONG LEG TOP TRACK POWDER DRIVEN FASTENER @ 24"oc CEILING AS SCHEDULED NO GWB ABOVE CEILING GRID @ CAVITY WALL CONDITION CEILING GRID SIDE 2 1/2' X 25 GA (18 MILS) METAL STUDS @ 24" OC, TO 10'-7" MAX. HEIGHT. INSULATION LION ON PLANS POWDER DRIVEN FASTENER @ 24"oc MET RUNNER TRACK SFALANT CONCRETE SLAB NON -RATED FLOOR TO DECK PARTITION NON -RATED FLOOR TO CEILING PARTITION NON -RATED FLOOR TO CEILING/DECK U 1 93 = 1 11-019 (V V� $11 3 K LJ_1__F_L — — — — — — 3" 1 l-011 = 1 11-039 3 0 4 8 12 0 4 8" 12 0 4 8 99 12 $9 DOOR & HARDWARE GENERAL NOTES 1. SEE BUILDING STANDARD FOR HARDWARE SPECIFICATIONS FOR HARDWARE, TYPES AND INSTALLATION. 2. DOOR WIDTH & HEIGHT ARE NOMINAL DIMENSIONS FROM JAMB TO JAMB AND FINISH FLOOR TO BOTTOM OF FRAME 0 HEAD. REFER TO SPECIFICATIONS FOR CLEARANCES. 3. DOUBLE DOOR NOMINAL WIDTH INDICATES 2 DOOR LEAVES OF EQUAL WIDTH, U.O.N. 4. DOOR CONSTRUCTION SHALL PROVIDE ATTACHMENT OF ALL HARDWARE WITHOUT THROUGH — BOLTS. 5. DOOR HARDWARE SHALL COMPLY WITH ALL APPLICABI E IBC & ACCESSIBILITY REQUIREMENTS. DOOR SCHEDULE DOOR C) M U.J C -D LIJ C.D Co C) CD :z 100 3'-0" 7'-0" 8 4 WD N/A BUILDING STANDARD ENTRY DOOR. VERIFY WITH BUILDING MGMT. 102 3'-0" 7'-0" A 1 WD N/A — 103 3'-0" 7'-0" EXIST. 1 WD N/A RELOCATED DOOR — VERIFY IF EXISTING HARDWARE TO REMAIN. 104 3'—On 7'-0" B 1 WD N/A RELOCATED DOOR — VERIFY IF EXISTING HARDWARE TO REMAIN. 105 3'—On 7'-0" B 1 WD N/A — 106A 3'-0" 7'-0" B 1 WD N/A — 106B S—On 7'-0" B 1 WD N/A — 108A 6'—On 7'-0" B 2 WD VERIFY WHICH SIDE TO HAVE THUMBTURN/KEYHOLE 108B 3'-0" 7'-0" A 2 WD — VERIFY WHICH SIDE TO HAVE THUMBTURN/KEYHOLE 108C 3'-0" 7'—On A 4 WD — BUILDING STANDARD ENTRY DOOR. VERIFY WITH BUILDING MGMT. 108D 3'—On 7'-0" A 4 WD — BUILDING STANDARD ENTRY DOOR. VERIFY WITH BUILDING MGMT. 108E 3'-0" 7'—On A 4 WD — BUILDING STANDARD ENTRY DOOR. VERIFY WITH BUILDING MGMT. 112 3'—On 7'-0" A 3 WD N/A 116 3'-0" 7'—On B 1 WD N/A 200 S—On 7'—On EXIST. 3 W + D — VERIFY TO REUSE RESTROOM HARDWARE. HARDWARE GROUP HARDWARE GROUP HARDWARE REMARKS GROUP 1 1 PASSAGE LATCHSET *ALL NEW HARDWARE TO MATCH SUITE SINGLE, PASSAGE LATCHSET 3 HINGES STANDARD. VERIFY FINAL STYLE/FINISH WITH NON—RATED 1 WALL—MOUNTED DOOR STOP BUILDING MANAGEMENT/ARCHITECT. GROUP 2 1 OFFICE FUNCTION LOCKSET *ALL NEW HARDWARE TO MATCH SUITE SINGLE, OFFICE LOCKSET 3 HINGES STANDARD. VERIFY FINAL STYLE/FINISH WITH NON—RATED 1 WALL—MOUNTED DOOR STOP BUILDING MANAGEMENT/ARCHITECT. GROUP 3 1 PRIVACY FUNCTION LOCKSET PRIVACY FUNCTION LOCKSET SHALL SINGLE, PRIVACY LOCKSET 3 PAIR HINGES HAVE OCCUPANCY SENSOR NON—RATED 1 WALL—MOUNTED DOOR STOP *ALL NEW HARDWARE TO MATCH SUITE STANDARD. VERIFY FINAL STYLE/FINISH WITH BUILDING MANAGEMENT/ARCHITECT. GROUP 4 1 ENTRY FUNCTION LOCKSET *ALL NEW HARDWARE TO MATCH BUILDING SINGLE, ENTRY LOCKSET 3 PAIR HINGES STANDARD. VERIFY FINAL STYLE/FINISH WITH NON—RATED 1 WAH —MOUNTED DOOR STOP BUILDING MANAGEMENT/ARCHITECT. 1 DOOR CLOSER DOOR TYPES BUILDING STANDARD to WOOD DOOR FINISH TO MATCH 1/4- TEMPERED SUITE STANDARD 1 6' GLASS INSERT BUILDING STANDARD FLUSH S.0 WOOD DOOR WOOD DOOR \' ;/ UJ FINISH TO MATCH FINISH TO MATCH SUITE STANDARD SUITE STANDARD FLUSH S.C. WOOD DOOR FINISH TO MATCH WIDTH wift SUITE STANDARD L' Ilk A B I E = EXISTING, MATCH ALL EXISTING CONDITIONS SIDELIGHT/GLAZING SCHEDULE W SIDELIGHT UJ M M ::kl �E W LU C-1) CD CD LU (n LU cw:. G1 4" M.E. 36" A 1/4" TEMPERED N/A WD PAINT GRADE FRAMES, MATCH EXISTING WOOD DOOR FRAMES. VERIFY FINAL STYLE 36" M.E. 72" B 1/4" TEMPERED N/A WD W/ BUILDING MANAGEMENT. SIDELIGHT/GLAZING TYPES E EXISTING, MATCH ALL EXISTING CONDITIONS IL % I BUILDING STANDARD— — I . WOOD FRAME L—DOUBLE JAMB FINISH TO MATCH STUD TO MATCH SUITE STANDARD WALL STUD GLAZING AS GAUGE. C.D SCHEDULED UJI LLJ C -D LL1 F — — — — — — — ���BOTTOM & TOP C=s I I 11 TRACKTO MATCH V) En M =11 I I WALL STUD GAUGE. I I J J -11 , IN — WIDTH WIDTH A Tenant: WESTERN FOODS/CORE GROUP ANDOVER EXECUTIVE PARK BUILDING 13 641 INDUSTRY DRIVE TUKWILA, WA 98188 A Tenant Improvement for: SKB COMPANY ANDOVER EXECUTIVE PARK 617 INDUSTRY DR. TUKWILA, INA 98188 B BURGESS L INTERIOR ARCHIJECTURE 1326 Fifth Avenue, Suite 400 1 Seattle, WA 98101 T 206 587 7120 W BurgessPNW.corn All reproduction & intellectual property rights reserved c 2015 Professional seal No. Issue Description Date REVIEW SET 08.15.16 REVISED REVIEW SET 08.23.16 FINAL REVIEW SET 09.12.16 PERMIT SET 09.20.16 CORRECTIONS SET 10.21.16 City Electronic Stamp REVIEWED FOR rR 0 COIDIE COMPLIANCE RECEIVED APPROV18D CITY OF TUKWI NOV 2 2 2016 OCT 24 2016 PERMIT CENTEk Cily of TUkwila UILDING DIVISION Drawn by: JG/MK Project Manager: RM Project No: -16.,3405.00 DOOR SCHEDULE SIDELIGHT SCHEDULE DETAILS Original drawing is 24" x 36". Scale entities accordingly if reduced -r Ir PROVIDE MIN 25 GA STUDS & ANCHOR BRACKET ANCHORAGES. DOUBLE STUDS @ END OF PARTITIONS. 3-#8 PAN HEAD SHT. MTL. SCREWS 6"06 GA UNPUNCHED STUD TRACK WITH FLANGES COPED AT VERTICAL STUDS. ATTACH TO TWO STUDS MIN. & EXTEND 6"MIN BEYOND MOUNTING POINT EACH DIRECTION. RM 1. TYPICAL ANCHOR BRACKET ASSEMBLY FOR HANDRAILS, GRAB BARS & TOILET ACCESSORY ANCHORAGES. 2. COORDINATE ANCHOR BRACKET LOCATION WITH ACCESSORY MANUFACURER MOUNTING INSTRUCTIONS. TYPICAL MTL. STUD ANCHOR BRACKET 12 GA. BRACING WIRE WITH MINIMUM 4 TIGHT TURNS IN 1 1/2' BOTH ENDS OF WIRE-TYP. - BASIS OF DESIGN: ARMSTRONG SUSPENSION SYSTEM ICCES REPORT ESR- 1289 MAX. TYP. CROSS RUNNER MAIN RUNNER DISTANCE FROM BRACING WIRES TO CROSS RUNNERS 8 GA. VERTICAL HANGER WIRE AT 4'-0" EACH WAY WITH MINIMUM 3 TIGHT TURNS IN 1 1/2" BOTH ENDS OF WIRE TYP. W2 NTS SEISMIC COMPRESSION STRUT 12'-0" O.C. MAX. IN EACH DIRECTION AS NEEDED. NOTE: PROVIDE ACT SUSPENSION GRID TO COMPLY WITH IBC 'k�, 2012 SECTION 1613 MINIMUM STANDARD PER ASCE 7-10, INSTALL PER MFRS. SPECS. VERIFY REQUIREMENTS WITH 5/8- G.W.B. ATTACHED CITY OFFICIALS. OTHER METHODS OF CONSTRUCTION MAY TO CROSS RUNNERS BE PERMITTED. VERIFY WITH BLDG MANAGEMENT AND CITY. ONLY. ( -,-,GWB SEISMIC SUSPENSION DETAIL -E= NOTE: WV111JINMIL MN%,nVf% ORM.,RLI LOCATIONS W/ CASEWORK & EQUIPMENT WHERE SCHEDUIED, AND MANUR MOUNTING INSTRUCTIONS Sol, NTS � I ) TYPICAL ANCHOR BRACKET FRAMING FOR WOOD CONSTRUCTION CONTRACTOR TO MODIFY CONSTRUCTION TO USE APPROPRIATE SCREW FASTENERS, #10 SCREWS MINIMUM CONTRACTOR TO VERIFY EXISTING CONDITION IN THE FIELD M 0 N L 1-1/2" x 1-1/2" x 2-1/2" W/ (2)#10 SCREWS TO STRUT AND (2) #10 SCREWS TO WOOD STRUCTURE COMPRESSION STRUT TYP. CEILING TRANSITION DETAIL 25 GA. 21" METAL - FRAMING @ 24" O.C. x X 20 GA. BOTTOM TRACK GWB HEADER EXISTING ACT NTS 3 I$= 1 1-019 2"X2"X12" MIN. LEG AT STRUCTURE - ATTACH W/2 POWDER DRIVEN FASTENERS PER BRACE OR OTHER APPROVED METHOD PROVIDE 20 GA METAL TOP TRACK WITH 2 POWDER DRIVEN FASTNERS AT 24" O.C. BOTTOM OF STRUCTURE PLENUM HEIGHT OF 5'-0" OR LESS 2 1/2"x25 CA METAL STUD BRACING AT EACH END AND CENTER OF SOFFIT. GWB CEILING HEADER DETAIL L -F -L -F -L ------ 0 4 8 12 3 IV= 1 9-099 IF NEEDED ACT SEISMIC BRACING DIAGRAM SPLAY WIRES SHALL BE FOUR 12 GAUGE ATTACHED TO THE MAIN BEAM. WIRES ARE ARRAYED 90' FROM EACH OTHER AND AT AN ANGLE NOT TO EXCEED 45' FROM THE PLANE OF THE CEILING. PER ASTM E 580. SPLAY WIRES ARE TO BE WITHIN 2* OF THE CONNECTION OF THE VERTICAL STRUT TO SUSPENDED CEILING. RIGID BRACING MAY BE USED IN LIEU OF SPLAY WIRES. PER ASTM E580. CEILING WITH PLENUMS LESS THAN 12" TO STRUCTURE ARE NOT REQUIRED TO HAVE LATERAL FORCE BRACING. NTS VERTICAL STRUTS MAY BE EMT CONDUIT, METAL STUDS OR PROPRIETARY COMPRESSION POST. VERTICAL STRUTS MUST BE POSITIVELY ATTACHED TO SUSPENSION SYSTEMS AND THE STRUCTURE ABOVE. PER ASTMI E580. WALL MOLDINGS WALL MOLDINGS (PERIMETER CLOSURE ANGLES) ARE REQUIRED TO HAVE A HORIZONTAL FLANGE 2' WIDE. ONE END OF THE CEILING GRID SHALL BE ATTACHED TO THE WALL MOLDING, THE OTHER END SHALL HAVE A 3/4' CLEARANCE FORM THE WALL AND BE FREE TO SLIDE. PER ASTIVI E580. WHERE SUBSTANTIATING DOCUMENTATION HAS BEEN PROVIDED TO THE LOCAL JURISDICTION, PERIMETER CLIPS MAY BE USED TO SATISFY THE REQUIREMENTS FOR THE 2' CLOSURE ANGLE. THE GRID SHALL BE ATTACHED AT TWO ADJACENT WALLS (POP RIVETS OR APPROVED METHOD). SOFFITS EXTENDING TO A POINT AT LEAST LEVEL WITH THE BOTTOM PLANE OF THE GRID AND INDEPENDENTLY SUPPORTED AND LATERALLY BRACED TO THE STRUCTURE ABOVE TARE DEEMED TO BE EQUIVALENT TO WALLS. PER ASTM E580. SPREADER BARS TERMINAL ENDS OF MAIN RUNNERS AND CROSS MEMBERS SHALL BE TIED TOGETHER OR HAVE SOME OTHER APPROVED MEANS TO PREVENT THEIR SPREADING. STABILIZER BARS, CROSS TEES OR OTHER MEANS TO PREVENT SPREADING SHALL OCCUR WITH 8" OF EACH WALL. PER ASTM E580. SPREADER BARS ARE NOT REQUIRED AT PERIMETERS WHERE RUNNERS ARE ATTACHED DIRECTLY TO CLOSURE ANGLES. SPREADER BARS ARE NOT REQUIRED IF A 9T INTERSECTING CROSS MAIN IS WITHIN 8* OF PERIMETER WALL WHERE SUBSTANTIATING DOCUMENTATION HAS BEEN PROVIDED TO THE LOCAL JURISDICTION, PERIMErER CLIPS MAY BE USED TO SATISFY THE REQUIREMENTS FOR THE SPREADER BARS. HANGER (SUSPENSION) WIRES HANGER AND PERIMETER WIRES MUST BE PLUMB WITHIN 1 IN 6 UNLESS COUNTER SLOPING WIRES ARE PROVIDED. PER ASTM C 636. HANGER WIRES SHALL BE 12 GAUGE AND SPACED 4' O.C. OR 10 GAUGE SPACE 5' O.C. PER ASTM C 636. ANY CONNECTION DEVICE AT THE SUPPORTING CONSTRUCTION SHALL BE CAPABLE OF CARRYING NOT LESS THAN 100 POUNDS. PER CISCA ZONES 3-4. POWDER DRIVEN FASTENERS ARE AN APPROVED METHOD OF ATTACHMENT FOR HANGER WIRE WITH THE MAINTENANCE OF ALL OTHER REQUIREMENTS. TERMINAL ENDS OF EACH MAIN BEAM AND CROSS TEE MUST BE SUPPORTED WITHIN 80 OF EACH WALL WITH A PERIMETER WIRE. PER ASTM E580. WIRE SHALL NOT ATTACH TO OR BEND AROUND INTERFERING MATERIAL OR EQUIPMENT. A TRAPEZE OR EQUIVALENT DEVICE SHALL BE USED WHERE OBSTRUCTIONS PRECLUDE DIRECT SUSPENSION. TRAPEZE SUSPENSIONS SHALL BE SIZED TO RESIST THE DEAD LOAD AND LATERAL FORCES APPROPRIATE FOR THE SEISMIC CATEGORY. PER ASTM E580. ELECTRICAL nXTURES LIGHT FIXTURES WEIGHING LESS THAN 10 POUNDS SHALL HAVE ONE 12 GAUGE HANGER WIRE CONNECTED FROM THE FIXTURE TO THE STRUCTURE ABOVE. THIS WIRE MAY BE SLACK. PER ASTM E580. LIGHT FIXTURES WEIGHING MORE THAN 10 POUNDS AND LESS THAN 56 POUNDS SHALL HAVE TWO 12 GAUGE WIRES ATTACHED AT OPPOSING CORNERS OF THE LIGHT FIXTURE TO THE STRUCTURE ABOVE. THESE WIRES MAY BE SLACK. PER ASTM E580. LIGHT FIX`rURES WEIGHING MORE THAN 56 POUNDS SHALL BE SUPPORTED DIRECTLY FROM STRUCTURE ABOVE BY APPROVED HANGERS PER ASTM E580. PENDANT MOUNTED FIXTURES SHALL BE DIRECTLY SUPPORTED FROM THE STRUCTURE ABOVE USING 9 GAUGE WIRE OR AN APPROVED ALTERNATE SUPPORT WITHOUT USING THE CEILING SUSPENSION SYSTEM FOR DIRECT SUPPORT. PER ASTM E580 TANDEM FIXTURES MAY UTILIZE COMMON WIRES. MECHANICAL SERVICES TERMINALS OR SERVICES WEIGHING LESS THAN 20 POUNDS SHALL BE POSITIVELY ATTACHED TO THE CEILING SUSPENSION MAIN RUNNERS OR TO CROSS RUNNERS THAT HAVE THE SAME CARRYING CAPACITY AS THE MAIN RUNNERS. PER ASTM E580 5.4.1. TERMINALS OR SERVICES WEIGHING 20 POUNDS BUT NOT MORE THAN 56 POUNDS MUST HAVE, IN ADDITION TO 5.4.1, TWO 12 GAUGE WIRES CONNECTING THEM TO THE CEILING SYSTEM HANGERS OR THE STRUCTURE ABOVE. THESE WIRES MAY BE SLACK. PER ASTM E580. TERMINALS OR SERVICES WEIGHING MORE THAN 56 POUNDS MUST BE SUPPORTED DIRECTLY FORM THE STRUCTURE ABOVE BY APPROVED HANGERS. PER ASCE 7-10. SEISMIC SEPARATION JOINTS FOR CEILING AREAS EXCEEDING 2500 S.F., A SEISMIC SEPARATION JOINT OR FULL HEIGHT WALL PARTITION THAT BREAKS THE CEILJNG SHALL BE PROVIDED UNLESS ANALYSES ARE PERFORM OF THE CEILING BRACING SYSTEM, CLOSURE ANGLES AND PENETRATIONS TO PROVIDE SUFFICIENT CLEARANCE. PER ASCE 7-10. THE AMOUNT OF FREE MOVEMENT (GAP) SHALL BE A MINIMUM OF 3/4 - IN LJEU OF SEISMIC SEPARATION JOINTS THE CEILING MAY BE DIVIDED INTO AREAS OF LESS THAN BY THE USE OF PARTITIONS OR SOFFITS AS FOLLOWS: PARTITIONS SHALL EXTEND A MINIMUM OF 6" ABOVE THE LEVEL OF THE PLANE OF THE GIRD AND SHALL BE UNDEPENDABLY BRACED TO THE STRUCTURE ABOVE. SOFFITS SHALL D(TEND TO A POINT AT LEAST LEVEL WITH THE BOTTOM PLAN OF THE GIRD AND SHALL BE INDEPENDENTLY SUPPORTED AND LATERALLY BRACED TO THE STRUCTURE ABOVE. ASTM E580. SPECIAL INSPECTIONS SPECIAL INSPECTIONS SHALL BE SUBJECT TO SPECIAL INSPECTION REQUIREMENTS. SPRINKLERS FOR CEILINGS WITHOUT RIGID BRACING, SPRINKLER HEAD PENETRATIONS SHALL HAVE A 2" OVERSIZE RING, SLEEVE OR ADAPTER THROUGH THE CEILING TILE TO ALLOW FREE MOVEMENT OF AT LEAST 1* IN ALL HORIZONTAL DIRECTIONS. FLEXIBLE HEAD DESIGN THAT CAN ACCOMMODATE 1* FREE MOVEMENT SHALL BE PERMITTED AS AN ALTERNATE. PER ASTM E580. M ACT NOTES NTS MI. -I" Tenant: WESTERN FOODS/CORE GROUP ANDOVER EXECUTIVE PARK BUILDING 13 641 INDUSTRY DRIVE TUKWILA, WA 98188 A Tenant Improvement for: SKB COMPANY ANDOVER EXECUTIVE PARK 617 INDUSTRY DR. TUKWILA, WA 98188 Omer BURGESS INTERIOR ARCHITECTURE 1326 Fifth Avenue, Suite 400 1 Seattle, WA 98101 T 206 587 7120 W Burgess!'NW.corn All reproduction & intellectual property rights reserved c 2015 Professional seal No. Issue Description Date REVIEW SET 08.15.16 REVISED REVIEW SET 08.23.16 FINAL REVIEW SET 09.12.16 PERMIT SET 09.20.16 CORRECTIONS SET 10.21.16 City Electronic Stamp Location REVIE F R CODE COMPLIANCE RECEIVED APPROVED I RE EIEED V W FO" ODE COMPLIAN' CITY OF TUKWILA APPROVED OCT 24 2016 NOV 2 2 2016 City of Tukwila PERMIT CENTER I IVISII BUILDING DIVISION_j Drown by: JG/Mk Project Manager: RM Project No: 16.3405.00 CEILING DETAILS Original drawing is 24" x 36". Scale entities accordingly if reduced A,902 VERIFY ALL REQUIREMENTS WITH BUILDING MANAGEMENT 12 GA. BRACING WIRE . SEISMIC COMPRESSION STRUT GENERAL REQUIREMENTS 12'-0" O.C. MAX. IN EACH A DIRECTION AS NEEDED. REFERENCED SOURCES PER HIERARCHY. IBC (INTERNATIONAL BUILDING CODE), AMERICAN SOCIETY OF TESTING MATERIALS (ASTM C 635, 12 GA. VERTICAL HANGER WIRE C636, E580, M580), AMERICAN SOCIETY OF CIVIL ENGINEERS (ASCE 7-10) AND CEILINGS AND INTERIOR SYSTEMS CONSTRUCTION '---�AT 4'-0" EACH WAY WITH ASSOCIA11ON (CISCA). BOTTOM OF FINISHED MINIMUM 3 TIGHT TURNS IN PARTITIONS THAT ARE TIED TO THE CEILING AND ALL PARTMONS GREATER THAN 6' IN HEIGHT SHALL BE LATOZAUY BRACED TO CEILING 1 1/2' BOTH ENDS OF WIRE STRUCTURE. BRACING SHALL BE INDEPENDENT OF CEILING SPLAY BRACING SYSTEM. PER ASCE 7-10. ALL MAIN BEAMS TO BE HEAVY DUTY, PER ASTM E580. MAX. TYP. CEILING LESS THAN OR EQUAL TO 144 SQ FF AND SURROUNDED BY WALLS CONNECTED TO THE STRUCTURE ABOVE ARE EXEMPT FROM SEISMIC REQUIREMENTS PER ASTM E580. THESE REQUIREMENTS ARE INTENDED FOR SUSPENDED CEILINGS AND RELATED COMPONENTS IN AREAS THAT REQUIRE RESISTANCE TO THE EFFECTS OF EARTHQUAKE MOTIONS, PER ASTM E580. ALL WIRE TIES ARE TO BE THREE TIGHT TURNS AROUND ITSELF WITHIN THREE INCHES. TWELVE GAUGE HANGER WIRE SPACED 4! O.C., PER ASTM C636 ITEM 2.3.4. M AXX CHANGES IN CEILING PLANES WILL REQUIRE POSITIVE BRACING. PER ASTM E580. TYP. LATERAL FORCE BRACING ANCHOR BRACKET: 6"X16ga UNPUNCHED STUD TRACK, CROSS RUNNER TYP. CEILING CONSTRUCTED OF SCREW OR NAIL ATTACHED GWB ON ONE LEVEL THAT ARE SURROUNDED BY AND CONNECTED TO WALLS OR ATTACH TO 3 STUDS MIN. SOFFITS THAT ARE LATERALLY BRACED TO THE STRUCTURE ABOVE ARE EXEMPT FROM SEISMIC REQUIREMENTS PER ASCE 7-10. MAIN RUNNER CEILING AREAS OF 1000 SQ Fr OR LESS SHALL BE EXEMPT FROM LATERAL FORCE REQUIREMENTS PER ASTME580. DISTANCE FROM BRACING LATERAL FORCE BRACING IS THE USE OF VERTICAL STRUTS (COMPRESSION POSTS) AND SPLAY WIRES. WIRES TO CROSS RUNNERS 2" MAX LATERAL FORCE BRACING SHALL BE 12 O.C. MAX. AND BEGIN NO FARTHER THAN 6' FROM WALLS. ASTM E580. PROVIDE ACT SUSPENSION GRID TO COMPLY WITH IBC SEC -1613 MINIMUM STANDARD: SEISMIC SPLAY WIRES SHALL BE ATTACHED TO THE GRID AND TO THE STRUCTURE IN SUCH A MANNER THAT THEY CAN SUPPORT A SEC11ON ASCE 7-10 13.5.6. SE WO ON DESIGN LOAD OF NOT LESS THAN 200 POUNDS OR THE ACTUAL DESIGN LOAD WITH A SAFETY FACTOR OF 2 WHICHEVER IS GREATER PER U/AJ11 CISCA ZONES 3-4. POWDER ACTUATED FASTENERS (PAF'S) WHEN USED FOR SEISMIC APPLICATIONS AS PART OF THE PRESCRIPTIVE PATH IN SEISMIC DESIGN FINISHED FLOOR USE OF 2" SEISMIC BERC CUP AT MOULDING CATEGORIES D, E, F SHALL HAVE AN ICC -ED APPROVAL FOR SEISMIC APPLICATIONS AND SHALL REQUIRE SPECIAL INSPECTION IRRESPECTIVE OF THE TYPE OF OCCUPANCY CATEGORY THE STRUCTURE IS IN. PAF ANCHORS FOR KICKER WIRES ARE EYEMPT FROM APPROVED BY CITY. T141S PF70111PPUFMT TYPICAL ANCHOR BRACKET FRAMING FOR WOOD CONSTRUCTION CONTRACTOR TO MODIFY CONSTRUCTION TO USE APPROPRIATE SCREW FASTENERS, #10 SCREWS MINIMUM CONTRACTOR TO VERIFY EXISTING CONDITION IN THE FIELD M 0 N L 1-1/2" x 1-1/2" x 2-1/2" W/ (2)#10 SCREWS TO STRUT AND (2) #10 SCREWS TO WOOD STRUCTURE COMPRESSION STRUT TYP. CEILING TRANSITION DETAIL 25 GA. 21" METAL - FRAMING @ 24" O.C. x X 20 GA. BOTTOM TRACK GWB HEADER EXISTING ACT NTS 3 I$= 1 1-019 2"X2"X12" MIN. LEG AT STRUCTURE - ATTACH W/2 POWDER DRIVEN FASTENERS PER BRACE OR OTHER APPROVED METHOD PROVIDE 20 GA METAL TOP TRACK WITH 2 POWDER DRIVEN FASTNERS AT 24" O.C. BOTTOM OF STRUCTURE PLENUM HEIGHT OF 5'-0" OR LESS 2 1/2"x25 CA METAL STUD BRACING AT EACH END AND CENTER OF SOFFIT. GWB CEILING HEADER DETAIL L -F -L -F -L ------ 0 4 8 12 3 IV= 1 9-099 IF NEEDED ACT SEISMIC BRACING DIAGRAM SPLAY WIRES SHALL BE FOUR 12 GAUGE ATTACHED TO THE MAIN BEAM. WIRES ARE ARRAYED 90' FROM EACH OTHER AND AT AN ANGLE NOT TO EXCEED 45' FROM THE PLANE OF THE CEILING. PER ASTM E 580. SPLAY WIRES ARE TO BE WITHIN 2* OF THE CONNECTION OF THE VERTICAL STRUT TO SUSPENDED CEILING. RIGID BRACING MAY BE USED IN LIEU OF SPLAY WIRES. PER ASTM E580. CEILING WITH PLENUMS LESS THAN 12" TO STRUCTURE ARE NOT REQUIRED TO HAVE LATERAL FORCE BRACING. NTS VERTICAL STRUTS MAY BE EMT CONDUIT, METAL STUDS OR PROPRIETARY COMPRESSION POST. VERTICAL STRUTS MUST BE POSITIVELY ATTACHED TO SUSPENSION SYSTEMS AND THE STRUCTURE ABOVE. PER ASTMI E580. WALL MOLDINGS WALL MOLDINGS (PERIMETER CLOSURE ANGLES) ARE REQUIRED TO HAVE A HORIZONTAL FLANGE 2' WIDE. ONE END OF THE CEILING GRID SHALL BE ATTACHED TO THE WALL MOLDING, THE OTHER END SHALL HAVE A 3/4' CLEARANCE FORM THE WALL AND BE FREE TO SLIDE. PER ASTIVI E580. WHERE SUBSTANTIATING DOCUMENTATION HAS BEEN PROVIDED TO THE LOCAL JURISDICTION, PERIMETER CLIPS MAY BE USED TO SATISFY THE REQUIREMENTS FOR THE 2' CLOSURE ANGLE. THE GRID SHALL BE ATTACHED AT TWO ADJACENT WALLS (POP RIVETS OR APPROVED METHOD). SOFFITS EXTENDING TO A POINT AT LEAST LEVEL WITH THE BOTTOM PLANE OF THE GRID AND INDEPENDENTLY SUPPORTED AND LATERALLY BRACED TO THE STRUCTURE ABOVE TARE DEEMED TO BE EQUIVALENT TO WALLS. PER ASTM E580. SPREADER BARS TERMINAL ENDS OF MAIN RUNNERS AND CROSS MEMBERS SHALL BE TIED TOGETHER OR HAVE SOME OTHER APPROVED MEANS TO PREVENT THEIR SPREADING. STABILIZER BARS, CROSS TEES OR OTHER MEANS TO PREVENT SPREADING SHALL OCCUR WITH 8" OF EACH WALL. PER ASTM E580. SPREADER BARS ARE NOT REQUIRED AT PERIMETERS WHERE RUNNERS ARE ATTACHED DIRECTLY TO CLOSURE ANGLES. SPREADER BARS ARE NOT REQUIRED IF A 9T INTERSECTING CROSS MAIN IS WITHIN 8* OF PERIMETER WALL WHERE SUBSTANTIATING DOCUMENTATION HAS BEEN PROVIDED TO THE LOCAL JURISDICTION, PERIMErER CLIPS MAY BE USED TO SATISFY THE REQUIREMENTS FOR THE SPREADER BARS. HANGER (SUSPENSION) WIRES HANGER AND PERIMETER WIRES MUST BE PLUMB WITHIN 1 IN 6 UNLESS COUNTER SLOPING WIRES ARE PROVIDED. PER ASTM C 636. HANGER WIRES SHALL BE 12 GAUGE AND SPACED 4' O.C. OR 10 GAUGE SPACE 5' O.C. PER ASTM C 636. ANY CONNECTION DEVICE AT THE SUPPORTING CONSTRUCTION SHALL BE CAPABLE OF CARRYING NOT LESS THAN 100 POUNDS. PER CISCA ZONES 3-4. POWDER DRIVEN FASTENERS ARE AN APPROVED METHOD OF ATTACHMENT FOR HANGER WIRE WITH THE MAINTENANCE OF ALL OTHER REQUIREMENTS. TERMINAL ENDS OF EACH MAIN BEAM AND CROSS TEE MUST BE SUPPORTED WITHIN 80 OF EACH WALL WITH A PERIMETER WIRE. PER ASTM E580. WIRE SHALL NOT ATTACH TO OR BEND AROUND INTERFERING MATERIAL OR EQUIPMENT. A TRAPEZE OR EQUIVALENT DEVICE SHALL BE USED WHERE OBSTRUCTIONS PRECLUDE DIRECT SUSPENSION. TRAPEZE SUSPENSIONS SHALL BE SIZED TO RESIST THE DEAD LOAD AND LATERAL FORCES APPROPRIATE FOR THE SEISMIC CATEGORY. PER ASTM E580. ELECTRICAL nXTURES LIGHT FIXTURES WEIGHING LESS THAN 10 POUNDS SHALL HAVE ONE 12 GAUGE HANGER WIRE CONNECTED FROM THE FIXTURE TO THE STRUCTURE ABOVE. THIS WIRE MAY BE SLACK. PER ASTM E580. LIGHT FIXTURES WEIGHING MORE THAN 10 POUNDS AND LESS THAN 56 POUNDS SHALL HAVE TWO 12 GAUGE WIRES ATTACHED AT OPPOSING CORNERS OF THE LIGHT FIXTURE TO THE STRUCTURE ABOVE. THESE WIRES MAY BE SLACK. PER ASTM E580. LIGHT FIX`rURES WEIGHING MORE THAN 56 POUNDS SHALL BE SUPPORTED DIRECTLY FROM STRUCTURE ABOVE BY APPROVED HANGERS PER ASTM E580. PENDANT MOUNTED FIXTURES SHALL BE DIRECTLY SUPPORTED FROM THE STRUCTURE ABOVE USING 9 GAUGE WIRE OR AN APPROVED ALTERNATE SUPPORT WITHOUT USING THE CEILING SUSPENSION SYSTEM FOR DIRECT SUPPORT. PER ASTM E580 TANDEM FIXTURES MAY UTILIZE COMMON WIRES. MECHANICAL SERVICES TERMINALS OR SERVICES WEIGHING LESS THAN 20 POUNDS SHALL BE POSITIVELY ATTACHED TO THE CEILING SUSPENSION MAIN RUNNERS OR TO CROSS RUNNERS THAT HAVE THE SAME CARRYING CAPACITY AS THE MAIN RUNNERS. PER ASTM E580 5.4.1. TERMINALS OR SERVICES WEIGHING 20 POUNDS BUT NOT MORE THAN 56 POUNDS MUST HAVE, IN ADDITION TO 5.4.1, TWO 12 GAUGE WIRES CONNECTING THEM TO THE CEILING SYSTEM HANGERS OR THE STRUCTURE ABOVE. THESE WIRES MAY BE SLACK. PER ASTM E580. TERMINALS OR SERVICES WEIGHING MORE THAN 56 POUNDS MUST BE SUPPORTED DIRECTLY FORM THE STRUCTURE ABOVE BY APPROVED HANGERS. PER ASCE 7-10. SEISMIC SEPARATION JOINTS FOR CEILING AREAS EXCEEDING 2500 S.F., A SEISMIC SEPARATION JOINT OR FULL HEIGHT WALL PARTITION THAT BREAKS THE CEILJNG SHALL BE PROVIDED UNLESS ANALYSES ARE PERFORM OF THE CEILING BRACING SYSTEM, CLOSURE ANGLES AND PENETRATIONS TO PROVIDE SUFFICIENT CLEARANCE. PER ASCE 7-10. THE AMOUNT OF FREE MOVEMENT (GAP) SHALL BE A MINIMUM OF 3/4 - IN LJEU OF SEISMIC SEPARATION JOINTS THE CEILING MAY BE DIVIDED INTO AREAS OF LESS THAN BY THE USE OF PARTITIONS OR SOFFITS AS FOLLOWS: PARTITIONS SHALL EXTEND A MINIMUM OF 6" ABOVE THE LEVEL OF THE PLANE OF THE GIRD AND SHALL BE UNDEPENDABLY BRACED TO THE STRUCTURE ABOVE. SOFFITS SHALL D(TEND TO A POINT AT LEAST LEVEL WITH THE BOTTOM PLAN OF THE GIRD AND SHALL BE INDEPENDENTLY SUPPORTED AND LATERALLY BRACED TO THE STRUCTURE ABOVE. ASTM E580. SPECIAL INSPECTIONS SPECIAL INSPECTIONS SHALL BE SUBJECT TO SPECIAL INSPECTION REQUIREMENTS. SPRINKLERS FOR CEILINGS WITHOUT RIGID BRACING, SPRINKLER HEAD PENETRATIONS SHALL HAVE A 2" OVERSIZE RING, SLEEVE OR ADAPTER THROUGH THE CEILING TILE TO ALLOW FREE MOVEMENT OF AT LEAST 1* IN ALL HORIZONTAL DIRECTIONS. FLEXIBLE HEAD DESIGN THAT CAN ACCOMMODATE 1* FREE MOVEMENT SHALL BE PERMITTED AS AN ALTERNATE. PER ASTM E580. M ACT NOTES NTS MI. -I" Tenant: WESTERN FOODS/CORE GROUP ANDOVER EXECUTIVE PARK BUILDING 13 641 INDUSTRY DRIVE TUKWILA, WA 98188 A Tenant Improvement for: SKB COMPANY ANDOVER EXECUTIVE PARK 617 INDUSTRY DR. TUKWILA, WA 98188 Omer BURGESS INTERIOR ARCHITECTURE 1326 Fifth Avenue, Suite 400 1 Seattle, WA 98101 T 206 587 7120 W Burgess!'NW.corn All reproduction & intellectual property rights reserved c 2015 Professional seal No. Issue Description Date REVIEW SET 08.15.16 REVISED REVIEW SET 08.23.16 FINAL REVIEW SET 09.12.16 PERMIT SET 09.20.16 CORRECTIONS SET 10.21.16 City Electronic Stamp Location REVIE F R CODE COMPLIANCE RECEIVED APPROVED I RE EIEED V W FO" ODE COMPLIAN' CITY OF TUKWILA APPROVED OCT 24 2016 NOV 2 2 2016 City of Tukwila PERMIT CENTER I IVISII BUILDING DIVISION_j Drown by: JG/Mk Project Manager: RM Project No: 16.3405.00 CEILING DETAILS Original drawing is 24" x 36". Scale entities accordingly if reduced A,902 0 1 0 4'-8" CLR FOR SINK VERIFY FOL REQ. DIANSONS FOR HOOD EQ. EQ. EQ. EQ. EQ. EQ. EQ. EQ. EQ. EQ. L— — — — — — — — — — — — — — — — — 7— =7— P -LAM UPPER CABINETS WITH TWO ADJUSTABLE SHELVES "J FPL --l] P -LAM COUNTERTOP FPL -11 P -LAM COUNTERTOP & BACKSPLASH & BACKSPLASH CASEWORK ELEVATION RM.#1 16 EQ. EQ o 4 o o o o o o o 4, o o o o o 29 -l's 04 6" MAX. e- —DRAWERS WITH ACCURIDE FULL EXT. GUIDES. —LOWER CLOSED CABINETS WITH TWO WHITE MELAMINE ADJUSTABLE SHELVES.FPL-2 LINE OF END OF WALL Al\ Al LINE OF CEILING AS SPECIFIED PLASTIC \J/ LAMINATE H/ DOORS 3' CLR. EQ. MELAMINE CABINET 109-01' CLR FOR KITCHEN EQUIPMENT EQ. EQ. EQ. 61-611 CASEWORK ELEVATION RM.#1 16 EQ. EQ o 4 o o o o o o o 4, o o o o o 29 -l's 04 6" MAX. e- —DRAWERS WITH ACCURIDE FULL EXT. GUIDES. —LOWER CLOSED CABINETS WITH TWO WHITE MELAMINE ADJUSTABLE SHELVES.FPL-2 LINE OF END OF WALL Al\ /fl\ LINE OF CEILING AS SPECIFIED PLASTIC LAMINATE H/ DOORS 3' CLR. EQ. MELAMINE CABINET 109-01' CLR FOR KITCHEN EQUIPMENT EQ. EQ. EQ. EQ. 61-811 3 8 99 1 9- 091 LINE OF CEILING AS SPECIFIED PLASTIC LAMINATE DOORS MELAMINE CABINET INTERIOR. 3/4" ADJ. SHELVES W/ MELAMINE FINISH. PROVIDE 1" SHELVES IF OVER 36" IN WIDTH. TASKLIGHT- WHERE OCCURS PER ELECTRICAL PLAN — PROVIDE 4" BACKSPLASH AS INDICATED ON ELEV. — SCRIBE TO WALL — CONTERTOP W/PLASTIC LAMINATE PER FINISH SCHEDULE, UNO. Cq PROVIDE SOLID PANEL — PROVIDE SINK WHERE INDICATED - REFER TO P LUMBING DWGS — PROVIDE ADA COMPLIANT SINK & FAUCET. PROVIDE CLEARANCES. PLUMBING BOOT AS REQ'D BASE AS PER SCHEDULE. TURN INSIDE @ CABINET OPENING, TYP. FINISH FLOOR LINE. RUN TO REAR OF CABINET OPENING. LINE OF CABINET (BEYOND) ADA SINK SECT)ON UJ UJ UJ (n > 93 9 10 1-1/2 1 0 99 of 19 0 1 2 3 V-239 EO. EQ o o e- 4 o o o o o o o o o o o 0 o o TYP. Z Ld z W a_ 0 ro Cq 0 04 TYPICAL CABINET SECTION _L _L ____ ___1 99 1 9— 091 L -F _F 1-1/2 99 is 91 0 04 _0 EQ. EQ. EQ. EQ. EQ. F—ADA COMPLIANT SINK & FAUCET I LINE OF END OF WALL -REFER TO FLR. PLANS LINE OF CEILING AS SPECIFIED PLASTIC LAMINATE DOORS 3' CLR. EQ. MELAMINE CABINET INTERIOR. 3/4" ADJ. SHELVES W/ MELAMINE FINISH. PROVIDE 1" SHELVES IF OVER 36" IN WIDTH. TASKLIGHT- WHERE OCCURS PER ELECTRICAL PLAN UJ UJ e- I (n 1� PROVIDE P -LAM BACK SPLASH AS INDICATED ON ELEV SCRIBE TO WALL > '�C-4 COUNTER TOP W/ PLASTIC LAMINATE PER FINISH SCHEDULE I IM X ®r o o o o o ADJ. SHELVES W/ MELAMINE FINISH BASE PER SCHEID. NISH FLOOR INE -- — — — — — - TYPICAL CABINET SECTION _L _L ____ ___1 99 1 9— 091 L -F _F 1-1/2 99 is 91 0 04 _0 EQ. EQ. EQ. EQ. EQ. F—ADA COMPLIANT SINK & FAUCET I -P-LAM UPPER CABINETS WITH TWO ADJUSTABLE SHELVES FPL -2] -P-LAM COUNTERTOP WITH 4" BACKSPLASH F-11 -DRAWERS WITH ACCURIDE FULL EXT. GUIDES. -P-LAM LOWER CABINETS AND DRAWER WITH ONE ADJUSTABLE SHELF J �A .9.3 > CASEWORK ELEVATION RM.#1 11 . to 11- 099 3/8 0 0 - I 04 0 0 0 I 10 EQ. EQ. EQ. LAM UPPER 3INETS WITH TWO JUSTABLE SHELVES L:-2] -LAM COUNTERTOP FH 4" BACKSPLASH NER CLOSED CABINETS *H TWO WHITE MELAMINE JUSTABLE SHELVES L:- 2: CASEWORK ELEVATION RM.#1 13 EQ. EQ. EQ. EQ. of 19- 099 3/8 EQ. EQ. EQ. EQ. EQ. EQ. �Q. X JPPER 3 WITH TWO BLE SHELVES COUNTERTOP BACKSPLASH WITH ACCURIDE 'LOSED CABINETS 3 WHITE MELAMINE _3LE SHELVES �PL-2 CASEWORK ELEVATION RM.#1 13 so 19- 091 3/8 RECEIVED CITY OF TUKWILA OCT 24 2016 PERMIT CENTER CENTERLINE OF DOOR AND TRANSITION STRIP DOOR AS SCHEDULED CARPETING AS SCHEDULED RESILIENT TRANSITION STRIP RESILIENT FLOOR AS SCHEDULED Tenant: WESTERN FOODS/CORE GROUP VER EXECUTIVE PARK BUILDING 13 641 INDUSTRY DRIVE TUKWILA, WA 98188 A Tenant Improvement for: SKB COMPANY ANDOVER EXECUTIVE PARK 617 INDUSTRY DR. TUKWILA, WA 98188 BURGESS INTERIOR ARCHITECTURE 1326 Fifth Avenue, Suite 400 1 Seattle, WA 98101 T 206 587 7120 W BurgessPNW.corn All reproduction & intellectual property rights reserved c 2015 Professional seal LL ALAN MORGAN OF WASHINGTON No. Issue Description Date REVIEW SET 08.15.16 REVISED REVIEW SET 08.23.16 FINAL REVIEW SET 09.12.16 PERMIT SET 09.20.16 CORRECTIONS SET 10.21.16 City Electronic Stamp Location REVIEMD FOR CODE COMPLIANCE APPROVED NOY 2 2 2016 City of Tukwila B1 III nIN DIVISION Drawn by: JG/MK Project manager: RM Project No: 16.3405.00 MILLWORK DETAILS Originol drawing is 24" x 36". Scale entities accordingly if reduced A*93 3' CLR. EQ. EQ. -P-LAM UPPER CABINETS WITH TWO ADJUSTABLE SHELVES FPL -2] -P-LAM COUNTERTOP WITH 4" BACKSPLASH F-11 -DRAWERS WITH ACCURIDE FULL EXT. GUIDES. -P-LAM LOWER CABINETS AND DRAWER WITH ONE ADJUSTABLE SHELF J �A .9.3 > CASEWORK ELEVATION RM.#1 11 . to 11- 099 3/8 0 0 - I 04 0 0 0 I 10 EQ. EQ. EQ. LAM UPPER 3INETS WITH TWO JUSTABLE SHELVES L:-2] -LAM COUNTERTOP FH 4" BACKSPLASH NER CLOSED CABINETS *H TWO WHITE MELAMINE JUSTABLE SHELVES L:- 2: CASEWORK ELEVATION RM.#1 13 EQ. EQ. EQ. EQ. of 19- 099 3/8 EQ. EQ. EQ. EQ. EQ. EQ. �Q. X JPPER 3 WITH TWO BLE SHELVES COUNTERTOP BACKSPLASH WITH ACCURIDE 'LOSED CABINETS 3 WHITE MELAMINE _3LE SHELVES �PL-2 CASEWORK ELEVATION RM.#1 13 so 19- 091 3/8 RECEIVED CITY OF TUKWILA OCT 24 2016 PERMIT CENTER CENTERLINE OF DOOR AND TRANSITION STRIP DOOR AS SCHEDULED CARPETING AS SCHEDULED RESILIENT TRANSITION STRIP RESILIENT FLOOR AS SCHEDULED Tenant: WESTERN FOODS/CORE GROUP VER EXECUTIVE PARK BUILDING 13 641 INDUSTRY DRIVE TUKWILA, WA 98188 A Tenant Improvement for: SKB COMPANY ANDOVER EXECUTIVE PARK 617 INDUSTRY DR. TUKWILA, WA 98188 BURGESS INTERIOR ARCHITECTURE 1326 Fifth Avenue, Suite 400 1 Seattle, WA 98101 T 206 587 7120 W BurgessPNW.corn All reproduction & intellectual property rights reserved c 2015 Professional seal LL ALAN MORGAN OF WASHINGTON No. Issue Description Date REVIEW SET 08.15.16 REVISED REVIEW SET 08.23.16 FINAL REVIEW SET 09.12.16 PERMIT SET 09.20.16 CORRECTIONS SET 10.21.16 City Electronic Stamp Location REVIEMD FOR CODE COMPLIANCE APPROVED NOY 2 2 2016 City of Tukwila B1 III nIN DIVISION Drawn by: JG/MK Project manager: RM Project No: 16.3405.00 MILLWORK DETAILS Originol drawing is 24" x 36". Scale entities accordingly if reduced A*93 WAREHOUSE SIDE EXISTING STUDS AND HEADER @ OPENING ATTACH NEW 25 GA. TOP TRACK TO HEADER W/2 #10 SCREWS @ 24 O.C. MOISTURE BARRIER PROVIDE THERMAL BATT INSULATION IN CAVITY. 25 GA METAL STUDS @ 24" O.C., MATCH EXISTING STUD DEPTH. 1 LAYER 5/8', TYPE 'X' GYP. BD. EA. SIDE OF METAL STUDS ATTACHED W/ #6 SCREWS 0 12' O.C. MAX. CEILING AS SCHEDULED SLOTTED LONG LEG TOP TRACK SYSTEM, SUCH AS STEELER INC DFT DEFLECTION TRACK 0 00 C�o xc> C3 V) C3 = LLJ CL 002 M BOTTOM OF STRUCTURE FIRE RATED SEALANT ALL PENETRATIONS TO HAVE FIRE CAULKING OR FIRE DAMPERS AS NECESSARY. NO VERTICAL PENETRATIONS OCCUR IN NEW CONSTRUCTION TYPE I KITCHEN HOOD, REFER TO MECHANICAL DRAWINGS BXUV.U419 FIRE RESISTANCE RATINGS: ANSIZUL 263 CHANNEL SHAPED, FABRICATED FROM MIN 20 GA. (33 MILS) CORROSION—PROTECTED STEEL, MIN. WIDTH TO ACCOMMODATE STUD SIZE, WITH MIN. 1' LONG LEGS, ATTACHED TO FLOOR AND CEILING WITH FASTENERS 24" OC. Mg. CHANNEL SHAPED, CORROSION —PROTECTED STEEL, MIN WIDTH 6" 25GA (18 MILS), MIN 1-1/4' FLANGES AND 1/4" RETURN, SPACED 16" OC. STUDS TO BE CUT 3/8" TO 3/4" LESS THAN ASSEMBLY HEIGHT. MAX HEIGHT 24'-6n MINERAL WOOL BATTS OR GLASSFIBER WITH UL CLASSIFICATION MARKINGFRICTION FITTED BETWEEN STUDS AND RUNNERS. MIN. THICKNESS 1-1/2". FIRE RATED SEALANT CONCRETE SLAB WHEN USED IN AN EXISTING ASSEMBLY CONTRACTOR MAY MODIFY DETAIL TO EXISTING CONDITIONS AS LONG AS THE RATING IS MAINTAINED. TRAINING ROOM/TYPE 1 HOOD NON -RATED INFILL PARTITION 1 HR RATED FLOOR TO CEILING/DECK L_F]�� 311 9-091 3 is 0 99 4 99 8 911 12 11 0 19 4 1110 8 1) 12 101 RECEIVED CITY OF TUKWILA OCT 24 2016 PERMIT CENTER Tenant: WESTERN FOODS/CORE GROUP ANDOVER EXECUTIVE PARK BUILDING 13 641 INDUSTRY DRIVE TUKWILA, WA 98188 A Tenant Improvement for: SKB COMPANY ANDOVER EXECUTIVE PARK 617 INDUSTRY DR. TUKWILA, WA 98188 BURGESS INTERIOR ARCHITECTURE 1326 Fifth Avenue, Suite 4001 Seattle, WA 98101 T 206 587 7120 W Burgess!'NW.corn All reproduction & intellectual property rights reserved c 2015 Professional seal IDALL ALAN MORGAN TE OF WASHINGTON No. Issue Description Date REVIEW SET 08.15.16 REVISED REVIEW SET 08.23.16 FINAL REVIEW SET 09.12.16 PERMIT SET 09.20.16 CORRECTIONS SET 10.21.16 City Electronic Stamp Location REVIEWED FOR CODE COMPLIANCE APPROVED RE PIEED F R W 0 0 C MP E DE 0 LIANC APPROVED Nov 2 2 2016 City of Tukwila IVISJON� 811111 DING DivisION Drawn by: JG/Ji�'�ro�iect M`=n1911: RM Project No: 16.3405.00 DETAILS Original drawing is 24" x 36". Scale entities accordingly if reduced (a) GYPSUM PANELS WITH BEVELED, SQUARE OR — — — — — — — — — — — — — — TAPERED EDGES, APPLIED VERTICALLY OR GALVANIZED SHEET STEEL WITH A MINIMUM HORIZONTALLY. VERTICAL JOINTS CENTERED THICKNESS OF .0236 INCH (.6010) (24GA), SPACED OVER STUDS AND STAGGERED ONE STUD CAVITY 1 INCH USING 1 INCH HIGH METAL HAT CHANNELS ON OPPOSITE SIDES OF STUDS. VERTICAL OFF THE COMBUS11BLE ASSEMBLY @ 24' O.C. JOINTS IN ADJACENT LAYERS (MULTILAYER (MEETS REQUIREMENTS OF SMC TABLE 308.6) SYSTEMS) STAGGERED ONE STUD CAVITY. HORIZONTAL JOINTS NEED NOT BE BACKED BY WALL TYPE "C" STEEL FRAMING. HORIZONTAL EDGE JOINTS AND HORIZONTAL BUTT JOINTS ON OPPOSITE SIDES OD STUDS NEED NOT BE STAGGERED. HORIZONTAL EDGE JOINTS AND HORIZONTAL BUTT STAINLESS STEEL FINISH ADHERED JOINTS IN ADJACENT (MULTI—LAYERED SYSTEMS) TO GALVANIZED STEEL STAGGERED A MIN OF 12". PROVIDE ONE LAYER TYPE'X' 5/8' THICK PER SIDE. @) TYPE S OR S-12 #6 STEEL SCREWS USED TO ATTACH PANELS TO STUDS (ITEM 2) OR FURRING JOINT COMPOUND CHANNELS (ITEM 6). SINGLE LAYER SYSTEMS: - 1 LONG FOR 1/2- AND 5/8- PANELS OR INSULATION 1-1/4" LONG FOR 3/4' THICK PANELS, SPACED WHERE NOTED 8" OC. WHEN PANELS ARE APPLIED HORIZONTALLY, OR 8" OC. ALONG VERTICAL AND BOTTOM EDGES AND 12" OC. IN THE FIELD THE PURPOSE OF THE 1—HOUR WALL Is TO WHEN PANELS ARE APPLIED VERTICALLY. PROVIDE 6" OF NON—COMBUSTIBLE MATERIAL FROM THE HOOD AND COMBUSTIBLE MATERIAL TO VINYL OR CASON, DRY OR PREMIXED JOINT MEET REQUIREMENTS OF IMC TABLE 308.6 COMPOUND APPLIED IN TWO COATS TO JOINTS AND SCREW HEADS OF OUTER LAYERS. PAPER TAPE, NOM 2' WIDE, EMBEDDED IN FIRST LAYER r— BOTTOM TRACK, OF COMPOUND OVER ALL JOINTS OF OUTER WITH POWER DRIVEN ATTACHMENT. LAYER PANELS. PAPER TAPE AND JOINT TOP TRACK SIMILAR COMPOUND MAY BE OMITTED WHEN GYPSUM PANELS ARE SUPPLIED WITH A SQUARE EDGE. FIRE RATED SEALANT CONCRETE SLAB WHEN USED IN AN EXISTING ASSEMBLY CONTRACTOR MAY MODIFY DETAIL TO EXISTING CONDITIONS AS LONG AS THE RATING IS MAINTAINED. TRAINING ROOM/TYPE 1 HOOD NON -RATED INFILL PARTITION 1 HR RATED FLOOR TO CEILING/DECK L_F]�� 311 9-091 3 is 0 99 4 99 8 911 12 11 0 19 4 1110 8 1) 12 101 RECEIVED CITY OF TUKWILA OCT 24 2016 PERMIT CENTER Tenant: WESTERN FOODS/CORE GROUP ANDOVER EXECUTIVE PARK BUILDING 13 641 INDUSTRY DRIVE TUKWILA, WA 98188 A Tenant Improvement for: SKB COMPANY ANDOVER EXECUTIVE PARK 617 INDUSTRY DR. TUKWILA, WA 98188 BURGESS INTERIOR ARCHITECTURE 1326 Fifth Avenue, Suite 4001 Seattle, WA 98101 T 206 587 7120 W Burgess!'NW.corn All reproduction & intellectual property rights reserved c 2015 Professional seal IDALL ALAN MORGAN TE OF WASHINGTON No. Issue Description Date REVIEW SET 08.15.16 REVISED REVIEW SET 08.23.16 FINAL REVIEW SET 09.12.16 PERMIT SET 09.20.16 CORRECTIONS SET 10.21.16 City Electronic Stamp Location REVIEWED FOR CODE COMPLIANCE APPROVED RE PIEED F R W 0 0 C MP E DE 0 LIANC APPROVED Nov 2 2 2016 City of Tukwila IVISJON� 811111 DING DivisION Drawn by: JG/Ji�'�ro�iect M`=n1911: RM Project No: 16.3405.00 DETAILS Original drawing is 24" x 36". Scale entities accordingly if reduced