Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Permit D16-0273 - CITY OF TUKWILA / CITY HALL - PRE-REROOF (NULL)
CITY OF TUKWILA CITY HALL 6200 SOUTHCENTER BLVD D16-0273 Parcel No: Address: City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-438-9350 Web site: http://www.TukwilaWA.gov DEVELOPMENT PERMIT 3597000282 Permit Number: 6200 SOUTHCENTER BLVD Project Name: CITY OF TUKWILA - CITY HALL Issue Date: Permit Expires On: D16-0273 3/24/2017 9/20/2017 Owner: Name: Address: Contact Person: Name: Address: Contractor: Name: Address: License No: Lender: Name: Address: TUKWILA CITY OF 6200 SOUTHCENTER BLVD , TUKWILA, WA, 98188 KENT HAKOLA 20203 BROADWAY AVE , SNOHOMISH, WA, 98296 SNYDER ROOFING OF WASH LLC 20203 BROADWAY AV , SNOHOMISH, WA, 98296 SNYDERW014MT CITY OF TUKWILA 6200 SOUTHCENTER BLVD , TUKWILA, WA, 98188 Phone: (206) 730-4082 Phone: (425) 402-1848 Expiration Date: 6/5/2017 DESCRIPTION OF WORK: TEAR OFF ONE SECTION, APPROX 1800 SF ICE AND WATER SHIELD, PERIMETER FLASHING, WALL FLASHING, AND OWENS CORNING TRUDIEF DURATION COMP SHINGLES. REMOVE EQUIP AND DEBRIS WHEN COMPLETE. Project Valuation: $12,099.00 Type of Fire Protection: Sprinklers: Fire Alarm: Type of Construction: Electrical Service Provided by: TUKWILA Fees Collected: $591.18 Occupancy per IBC: Water District: TUKWILA Sewer District: TUKWILA Current Codes adopted by the City of Tukwila: International Building Code Edition: International Residential Code Edition: International Mechanical Code Edition: Uniform Plumbing Code Edition: International Fuel Gas Code: 2015 2015 2015 2015 2015 National Electrical Code: WA Cities Electrical Code: WAC 296-46B: WA State Energy Code: 2014 2014 2014 2015 Public Works Activities: Channelization/Striping: Curb Cut/Access/Sidewalk: Fire Loop Hydrant: Flood Control Zone: Hauling/Oversize Load: Land Altering: Landscape Irrigation: Sanitary Side Sewer: Sewer Main Extension: Storm Drainage: Street Use: Water Main Extension: Water Meter: Volumes: Cut: 0 Fill: 0 Number: 0 No Permit Center Authorized Signature: kiL3AL J Date: I hearby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this development permit and agree to the conditions attached to this permit. Signature: Print Name: H lc6m/1. Dater Z q-( This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: ***BUILDING PERMIT CONDITIONS*** 2: Work shall be installed in accordance with the approved construction documents, and any changes made during construction that are not in accordance with the approved construction documents shall be resubmitted for approval. 3: All permits, inspection record card and approved construction documents shall be kept at the site of work and shall be open to inspection by the Building Inspector until final inspection approval is granted. 4: All construction shall be done in conformance with the Washington State Building Code and the Washington State Energy Code. 5: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of this requirement. 6: Prior to final inspection for this building permit, a copy of the roof membrane manufacturer's warranty certificate shall be provided to the building inspector. 7: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 1700 BUILDING FINAL** 0103 PRE-REROOF CITY OF TUIOI _LA Community Development Department Public Works Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.TukwilaWA.gov Building Permit No. 11(0,-- O2 12) Project No. Date Application Accepted: 0 ((0 Date Application Expires: y' I I (For office use only) CONSTRUCTION PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **Please Print** SITE LOCATION King Co Assessor's Tax No.: Site Address: b Ze O 1'�c i tt C%r.i ? LJO tLw:r a4 %i%1812 Suite Number: Floor: Tenant Name: Cti i O t tcwli.A C��. t�Ri New Tenant: ❑ Yes ❑..No PROPERTY OWNER Name: 14.4.4 tk -p1 Address: 20201 13RoltlJi,,,ili Aoa- Name: Phone: 42.cFax: Address: 20.0.2, i)).0" Address: it zoo c- ii)t._\3O . City: ' \ tA`L3.11',A State: Zip: Gm 1 CONTACT PERSON - person receiving all project communication Name: 14.4.4 tk -p1 Address: 20201 13RoltlJi,,,ili Aoa- City: si4003wttcty State: i BUILDING PERMIT INFORMATI\ 206-431-3670 Valuation of Project (contractor's bid price): $ Vile) q I Existing Building Valuation: $ Describe the scope of work (please provide detailed information): 1 +u+A- oft=CI) v,.tt Siu.>`i3..1 , A. it04 vim -,1i Ail SR o CO*43Sr,too,J g444-tt i .1-141 CAN ilUAAAt-r4 • ? F (1 t-Aci- l4 40 ,RS Ncc.assA- yyt,t I, c4 f W Al (L kk 4 O , t` Sti gat+ , wAu %tAi+li in k 4� ASD O 14 4.1S C.OQ4+s0 C DwiltivA3,4 Cov-postTio,a way.)i. A.r.o 0'4E4, (2-4, tt+,i,.._ c q+-r�.,�- Will there be new rack storage? ❑ Yes ❑.. No If yes, a separate permit and plan submittal will be required. Provide All Building Areas in Square Footage Below PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact: Handicap: Will there be a change in use? ❑ Yes ❑ No If "yes", explain: FIRE PROTECTION/HAZARDOUS MATERIALS: ❑ Sprinklers ❑ Automatic Fire Alarm 0 None ❑ Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes ❑ No If `yes', attach list of materials and storage locations on a separate 8-1/2"x 11" paper including quantities and Material Safety Data Sheets. SEPTIC SYSTEM ❑ On-site Septic System — For on-site septic system, provide 2 copies of a current septic design approved by King County Health Department. H:\Applicat ions\Forms-Applications On Line \201 I Applications\Pennit Application Revised - 8-9-1 I.docx Revised: August 2011 bh Page 2 of 4 Existing Interior Remodel Addition to Existing Structure New Type of Construction per IBC Type of Occupancy per IBC 1S1 Floor rd Floor 3rd Floor Floors thru Basement Accessory Structure* Attached Garage Detached Garage Attached Carport Detached Carport Covered Deck Uncovered Deck PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact: Handicap: Will there be a change in use? ❑ Yes ❑ No If "yes", explain: FIRE PROTECTION/HAZARDOUS MATERIALS: ❑ Sprinklers ❑ Automatic Fire Alarm 0 None ❑ Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes ❑ No If `yes', attach list of materials and storage locations on a separate 8-1/2"x 11" paper including quantities and Material Safety Data Sheets. SEPTIC SYSTEM ❑ On-site Septic System — For on-site septic system, provide 2 copies of a current septic design approved by King County Health Department. H:\Applicat ions\Forms-Applications On Line \201 I Applications\Pennit Application Revised - 8-9-1 I.docx Revised: August 2011 bh Page 2 of 4 PERMIT APPLICATION NOTES — Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER A ORIZED AGENT: Signature: Date: 1.0( ti I Us+ Print Name: --ZVAI Efli L-wtA-n4 Day Telephone: 4v'- Lot- 1 '+j Mailing Address: o2O203 a@o?Dw34 Pt -JE, siAottogtvS1k I- A q$v462.. City State Zip H:tApplications\Forms-Applications On Line\20 I I Applications\Permit Application Revised - 8-9-I I.docx Revised: August 2011 bh Page 4 of 4 Cash Register Receipt City of Tukwila DESCRIPTIONS I ACCOUNT QUANTITY PermitTRAK PAID $591.18 D16-0273 Address: 6200 SOUTHCENTER BLVD Apn: 3597000282 $591.18 DEVELOPMENT $573.92 PERMIT FEE R000.322.100.00.00 0.00 $345.10 PLAN CHECK FEE R000.345.830.00.00 0.00 $224.32 WASHINGTON STATE SURCHARGE B640.237.114 0.00 $4.50 TECHNOLOGY FEE $17.26 TECHNOLOGY FEE TOTAL FEES PAID BY RECEIPT: R9612 R000.322.900.04.00 0.00 $17.26 $591.18 Date Paid: Tuesday, October 11, 2016 Paid By: SNYDER ROOFING Pay Method: CHECK 4362 Printed: Tuesday, October 11, 2016 12:37 PM 1 of 1 CPSYSTEMS INSPECTION RECORD Retain a copy with permit ���~��'�3 INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188\V (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project: airy h -t Type of Inspection: Bpi L NNC- Fit &c. Address: 626n &I.0714cAAPVA Date Called: Special Instructions: Date Wanted: '7-2 ii -/7 a.m. p.m. Requester: Phone No: EZApproved per applicable codes. LJ Corrections required prior to approval. COMMENTS: ,SOI LPI J- Fft f -L Inspector: H Date: 7-2ij-/ REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION NO. INSPECTION RECORD Retain a copy with permit DitQ -02.73 PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project: >ry Mu/ Type of Inspection: CfrettrreAg Address: 40 ZOO ..viTi-/,,fivizrig Date Called: Special Instructions: Date Wanted: 7.-2 2.17 a.m. p.m. Requester: Phone No: fJApproved per applicable codes. LJ Corrections required prior to approval. COMMENTS: 6k` RX RAST (4,1)Or ,C#14-rih G-) Inspector: Date:7-22.7 REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 We -0273 Projj�+ect: C jT/y / Type of Inspection: PJk -R Pc - Address: 6 -v^s R ADS Date Called: Special Instructions: Date Wanted: 7'-Z /-17 a.m. P.m. Requester: Phone No: Approved per applicable codes. El Corrections required prior to approval. COMMENTS: Our C= A)Si r 70,4/ ,NNP 7740l„1 Inspector: r.� Date: 7-2/-17 .2j '` REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. REVISIONS No chances shag be made to the scope of work veithaut prior approval of Tu' wila Building Division. NOTE: Revisions will require a new plan submittal and may include additional plan review fees. REVIEWED FOR CODE COMPLIANCE APPROVED OCT 14 2016 City of Tukwila BUILDING DIVISION vEr A . ,I E PERMIT f:,:EQLNI ED FOR: +achanical clectricat Rejp binp as Piping City of Tukwila if.t.iliTS,NNG DIVISION MEE Win Permit No, ..N.3 Plan review approval is subject to errors and omissions. Approval of construction documents does not authorize the violation of any adopted code or ordinance. Receipt of approved Field Copy and co ditions is acknowledged: By:L 1 Date:'�— City of Tukwila BUILDING DIVISION bE(sO273 10/11/2016 Google Maps Google Maps : • P.omm riity Department 4 -4, I https://www.google.com/maps/©47.4631002,-122.2555351,93m/data=!3m1!1e3 Go gte '• („22,00 1:)otick--1/4k (3,L7REVIEWED FOR CODE COMPLIANCE 1 u.g.tat.L.A. LW< °1Q%t, APPROVED OCT 14 2016 City of Tukwila BUILDING DIVISION RE -CITY Imagery ©2016 Google, Map data ©2016 Google 50 ft OCT 1 1 2016 PERMIT CENTER DI 41- 01-1(1? 1/1 ily,JC)� TUK UILDrNG Di Snyder Building more: 20203 Broadway Ave, Snohomish WA 98296 www.snyder-builds.com FILE City of Tukwila - City Hall Material List 19 Squares Owens Corning TruDef Duration Driftwood 9 Rolls Owens Corning Weatherlock Ice & Water Shield 2 Bundles Owens Corning Starter Shingles 1 Box 1 1/4" coil nails 4 Each Temporary Roof Anchors 3 Pcs 1" x 3" Starter Metal Brown 26 gauge 2 Bndls 8" x 8" Step Shingles Brown 26 gauge 3 Pcs Clear Story Metal Brown 26 gauge 10 Pcs 3" x 3" Rake Metal Brown 26 gauge 1 Box A-11 Staples 1 Each 1 1/2" Flex Lead Flashing 20 Each Grommet Screws Brown 1 Roll Visqueen Cones, Caution Tape, Ropes, Harnesses, Caution Workers Above Signs, Spud Shovels, Scoop Shovels, Brooms, Compressor, Hose, Nail Guns, etc. REVIEWED FOR CODE COMPLIANCE APPROVED OCT 14 2016 City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA • OCT 1 1 2016 PERMIT CENTER P14 -OZ'S ENERGY STAR® IS FOR ROOFS TOO Similar to the energy-efficient appliances in your home, roofing products can provide energy- saving qualities. Owens Corning® ENERGY STAR® qualified shingles can help reduce your energy bills when installed properly. These shingles reflect solar energy, decreasing the amount of heat transferred to a home's interior — and the amount of air conditioning needed to keep it comfortable. Actual savings will vary based on geographic location and individual building characteristics. Call 1 -800 -GET -PINK® or 1 -888 -STAR -YES for more information. ENEBGYSJAR Product Attributes Warranty Length* Limited Lifetime# (for as long as you own your home) Wind Resistance Limited Warranty* 130 MPH Algae Resistance Limited Warranty* 10 Years Algae resistance available in areas shown in white. Tru PROtection® Non -Prorated Limited Warranty* Period 10 Years TruDefinition® Duration® Shingles Product Specifications Nominal Size 131/4" x 393/e" Exposure 5 s/e" Shingles per Square 64 Bundles per Square 3 Coverage per Square 98.4 sq. ft. Applicable Standards and Codes ASTM D228 ASTM D3018 (Type 1) ASTM D3462 ASTM D3161 (Class F Wind Resistance) ASTM D7158 (Class H Wind Resistance) ASTM E108/UL 790 (Class A Fire Resistance) ICC -ES AC438# UL ER2453-01## Shasta White color meets ENERGY STAR' requirements for initial solar reflectance of 0.25 and 3 -year aged solar reflectance of 0.15; 2013 California Building Energy Efficiency Standards, Title 24, Part 6 requirements; rated by the Cool Roof Rating Council (CRRC). * See actual warranty for complete details, limitations and requirements. ** 2016 Roofing Homeowner Brand Awareness Survey by Owens Corning Roofing and Asphalt. LLC. t Owens Corning Roofing strives to accurately reproduce photographs of shingles. Due to manufacturing variances, the limitations of the printing process and the variations in natural lighting, actual shingle colors and granule blends may vary from the photo. The pitch of your roof can also impact how a shingle looks on your home. We suggest that you view a roofing display or several shingles to get a better idea of the actual color. To accurately judge your shingle and color choice, we recommend that you view it on an actual roof with a pitch similar to your own roof prior to making your final selection. Color availability subject to change without notice. Ask your professional roofing contractor for samples of colors available in your area t This illustration depicts Triple Layer Protection' and the amount of Triple Layer Protection' may vary on a shingle -to -shingle basis. $ Tru -Bond' is a proprietary premium weathering -grade asphalt sealant that is blended by Owens Corning Roofing and Asphalt, LLC. $ $ 40 -Year Limited Warranty on commercial projects. # International Code Council Evaluation Services Acceptance Criteria for Alternative Asphalt Shingles. ## Underwriters Laboratories Evaluation Service Evaluation Report. Owens Corning Roofing Preferred Contractors are independent contractors and are neither affiliates nor agents of Owens Corning Roofing and Asphalt, LLC, or its affiliated companies. SureNail' Technology U.S. Patent 7,836,654 and other patents pending. ENERGY STAR and the ENERGY STAR mark are registered trademarks of the U.S. Environmental Protection Agency. ^ Excludes non -Owens Corning' roofing products such as flashing, fasteners and wood decking. Shingles are algae resistant to control the growth of algae and discoloration. HOME SWEET HOME Your home is your sanctuary. It's the place where you want to feel the most comfortable. Safe. Protected. But no matter how much you love your house, it seems the work is never completely done. And if purchasing a new roof is on your to-do list, it may seem like a daunting task — especially if your roof is already damaged or leaking. Since a roof plays such an important role in protecting you and your family from the elements, you realize that you can't let the damage get out of hand. Don't worry, we know that a roof replacement project is a big, important decision. You can feel confident about choosing our roofing products — Owens Corning has been a recognized leader in the building industry for over 75 years. In fact, we're America's #1 most trusted roofing brand.** Not only can we help you choose the right shingle and roofing system components, we can also help you select the right contractor for the job — an Owens Corning Roofing Preferred Contractor. Together we can make this a positive experience — an opportunity, really. This is your chance to choose a roof that not only has outstanding performance, but also has exceptional beauty. So for years to come, you'll feel great every time you pull in the driveway. Protected. Proud. Home. ROOFING 'SYSTEM The Total Protection Roofing System®" Working together to help protect and enhance your home. It takes more than just shingles to protect your home. It takes an integrated system of components and layers designed to withstand the forces of nature outside while controlling temperature and humidity inside. The Owens Corning® Total Protection Roofing System" gives you the assurance that all of your Owens Corning® roofing components are working together to help increase the performance of your roof — and to enhance the comfort and enjoyment of those who live beneath it. O Owens Corning® Hip & Ridge Shingles 0 VentSure® Exhaust Ventilation Products © Owens Corning® Shingles 0 Owens Corning® Starter Shingle Products 0 Owens Corning® Underlayment Products ©WeatherLock®Self-Sealing Ice o , & Water Barrier Products VentSure® Soffit or InFlow® Intake Mr Ventilation Products o Optional Owens Corning® products designed to support the Total Protection Roofing System" - PINK® FIBERGLAS° Blown -In Insulation - raft -R -mate® Attic Rafter Vent ^Excludes non -Owens Corning• roofing products such as flashing, fasteners and wood decking. Help prevent heat and moisture buildup in the attic by allowing fresh air to enter the attic. Help protect vulnerable areas where water can do the most damage: eaves, valleys, dormers and skylights. Help prevent damage from wind -driven rain by providing an additional layer of protection between the shingles and roof deck. Enjoy clean lines and faster, easier installation by eliminating the need to cut shingle tabs. Choose from a variety of durable styles and colors that provide the first line of defense against the elements. Help protect your roofing system by allowing heat and moisture to escape from the attic. Help protect the ridge vent and add an attractive, finished look to your entire roof. OWENS CORNING OWENS CORNING ROOFING AND ASPHALT, LLC ONE OWENS CORNING PARKWAY TOLEDO, OHIO, USA 43659 ® 1 -800 -GET -PINK® www.owenscorning.com/roofing Pub. No. 10014053-E. Printed in U.S.A. April 2016. THE PINK PANTHER- & ©1964-2016 Metro -Goldwyn -Mayer Studios Inc. All Rights Reserved. The color PINK is a registered trademark of Owens Corning.©2016 Owens Corning. All Rights Reserved. (Compton, Denver, Portland) ROOFING SYSTEM TruDefinition® DURATION® SHINGLES with SureNail°Technology TruDefinition® Duration' Shingles are a component of the Owens CornineTotakProtection Roofing Systern:&^ �~�mn��,��| if' �° mnme����//[l.OK�// DURATION® SHINGLES with SureNair Technology Bold contrast. Deep dimension. ��N~NN ����������wc> �m�w����0NmmN�N��0Nm TruDefinition® Duration® Shingles are specially formulated to provide great contrast and dimension to any roof. Through the use of multiple granule colors and shadowing, TruDefinition Duration Shingles offer a truly unique and dramatic effect. This exclusive combination of color and depth is what makes TruDefinition Duration Shingles like no other. TruDefinition Duration Shingles aravailable in popular colors with bold, lively contras and complementing shadow lines for greater dimension. They feature a Limited Lifetime Warranty*/ (for as long as you own your home), 130 -MPH Wind Resistance Limited Warranty* and an Algae Resistance Limited Warranty.* Beyond the outstanding curb appeal and impressive warranty coverage, they also come with the advanced performance of patented SureNail Technology. The SureNailDifferenoa— ' - . �~,^~ '� u��m �\technological breakthrough Technology in roofing. The innovative features of Owens Corning® TruDefinition® Duration® Shingles with patented SureNail® Technology offer the following: Breakthrough Design. Featuring a tough, woven engineered reinforcing fabric to deliver consistent fastening during installation. Triple Layer Pvmtaction!A unique "triple layer" of reinforcement occurs when the fabric overlays the common bond of the shingle laminate layers that offers excellent fastener holding power. Superior Adhesion. Our enhanced Tru -Bond® sealant grips tightly to the engineered fabric nailing strip on the shingle below. Excellent Adhesive Power. Specially formulated, wide adhesive bands help keep shingle layers laminated together. Exceptional Wind Resistance. Engineered to deliver 130'K4PH°vvind warranty performance with only 4 nails. Fewer nails required can mean fewer deck penetrations. SureNail°neinmrcing Woven Fabric Nailing Area ., Ji--.'".,./ WIIIIIVallbo.: 11 '4111-18-1-11°-_-.11.00`- �414Illb ' r 1111% 4441100. ' Triple Layer protection" Excellent Adhesive Power Enhanced Tru -Bond° Sealant ` | COLORS AVAILABLE IN ALL SERVICE AREAS—see map below Desert Tant Brownwoodt Quarry Grayt Sierra Grayt Teakt Shasta Whitet FP X t. ',;„.,,,,,,„":1i,,,:41_4':..A,?: z 0 . ,.. , , ,...,,_.314., ;#.4 ,:410:::‘,':,:::',1,1:1;97z,...,-;,4:,,,,,,,,,,r,,,i. . .7:_i:-;;,...it;i,,,,!.:‘,..;,'i,",:itiffi.,_,,,::1't..,:,- 4 41 • ''';'.,-.; :, ,', , W • Shasta Whitet Harbor Bluet Onyx Blackt Chateau Greent Estate Grayt ADDITIONAL COLORS AVAILABLE BY SERVICE AREA—see map below FP X t. ',;„.,,,,,,„":1i,,,:41_4':..A,?: z 0 . ,.. , , ,...,,_.314., ;#.4 ,:410:::‘,':,:::',1,1:1;97z,...,-;,4:,,,,,,,,,,r,,,i. . .7:_i:-;;,...it;i,,,,!.:‘,..;,'i,",:itiffi.,_,,,::1't..,:,- 4 41 Harbor Bluet Onyx Blackt Chateau Greent Estate Grayt ADDITIONAL COLORS AVAILABLE BY SERVICE AREA—see map below Ambert Not available in Service Area 13. FP X t. 4 41 • 4.4 • Ambert Not available in Service Area 13. t. 4 41 • 4.4 • Oyster Shellt Not available in Service Areas 12,13. Antique Silvert Not available in Service Areas 12,13. Terra Cottat COLOR AVAILABILITY MAP t. Antique Silvert Not available in Service Areas 12,13. Terra Cottat COLOR AVAILABILITY MAP 10/11/2016 Owens Corning 0 (/roofing/shingles/favorites) 9 98036 I CHANGE ZIP FILE BOLD CONTRAST. DEEP DIMENSION. OUTSTANDING PERFORMANCE. TruD TruDefinitiQn Duration Shingles are specially formulated to provide dramatic color contrast and, dimension _r'ECEIVED to any roof finition anal are available in al e popular colors. Beyond the impressive curb appeal, they also come with the advanced DU RATIONt d SureNail® Tee el kthrough in roofing. REVIEWED FOR CrT�' O TUK�VILA CODE COMPLIANCE APPROVED SHINGLES O VIEW PHOTO GALLERY $$ 9cT 1 4 AV OCT 1 1 2016 $$$$ ,E�crvu 1$ff$ TER Roofing (/roofing) / Pick Your Shingles (/roof" gLsf" �L Noofshingles/trudefnition-duration) BU Goofi COLOR OPTIONS PERMIT CENTER (/roofing/shOgiefifigldhfigii£iiigfdbfUti oliiig/d6finpraltrudeXtritiofiag/shOg ifigldhi fgt Eilig/d6ttg ifig/db iigkibfirf duration/broakrratimd hadeeation/destrtation/driftwood) duration/hartioration/onOtiration/quattyation/shaftaation/sierrE green) tan) blue) ) I gray) https://www.owenscorning.com/roofing/shingles/trudefinition-duration#technical-docs 1/5 10/11/2016 (/roofing/shingles/trudefinition- duration/teak) TruDefinition Duration Shingles ESTATE GRAY Owens Corning FIND A CONTRACTOR WHERE TO BUY > FAVORITE SHARE V ORDER PRINTED SAMPLEMEM NEXT STEPS Trul efinition Duran "Shingles ESTATE r' Aw. and compare Owens Coming Roofing warranties, or register your warranty online. Leary More • • akes ru'ore than j earn Mote UT Obi TOTAL PROTECTION ROOFING S our home. Ktakes an integrated system of components design https://www.owenscorning.com/roofing/shingles/trudefinition-duration#technical-docs 2/5 10/11/2016 Owens Corning u • ` ,� � •ter < Tye, �•� BROWSE HIR &:RIDQ '}SCAt G SS tk n . oi.Pcan g t with thrs shingle tine. FEATURES TECHNICAL SPECIFICATIONS TECH SPECS Warranty Length * ' Limited Lifetime (for as long as you own your home)* ritanahDefinition Dur4li®rMpH Shingles stanESTATE G RAS'ears Nominal Size 13 1/4" x 39 3/8" Exposure Shingles Per Square Bundles Per Square Coverage Per Square 5 5/8" 64 3 98.4 sq. ft. TECHNICAL DOCUMENTS 3 -part spec (pdf) (http://www.owenscorning.com/NetworkShare/Roofing/3-Part-Specifications-Master.pdf) 3 -part spec (word) (http://www.owenscorning.com/NetworkShare/Roofing/10019190-Roofing-3-Part- SpecWord-Version.docx) https://www.owenscorning.com/roofing/shingles/trudefinition-durationntechnical-docs 3/5 10/11/2016 Owens Corning ,Data Sheet (http://www.owenscorning.com/NetworkShare/Roofing/10014053 TruDefinition%C2%AE- Duration%C2%AE-Shingles-Data-Sheet.pdf) Install Instructions (http://www.owenscorning.com/NetworkShare/Roofing/10014283-TruDefinition%C2%AE- Duration%C2%AE-Series-Shingles-Installation-Instructions.pdf) LEED Certification - Roofing Shingles' (http://www.owenscorning.com/NetworkShare/Sustainability/10011706.pdf) UL Evalutation Report (http://www.owenscorning.com/uploadedFiles/DMS/Roofing/U L_Evaluation_Report_R2453-01 _Revised- AC438_and Tri_BuiltStarter Strip.pdf) APPLICABLE STANDARDS CSA A123.5 2 ASTM D3018 (Type 1) ASTM D7158 (Class H Wind Resistance) UL 790 (Class A Fire Resistance) ASTM E108 (Class A Fire Resistance) ASTM D3462 ASTM D228 61 (Srat®lefirnlrtrn Shingles 3-01 ESTATE GRAY ICC -FS AC438 4 *See actual warranty for complete details, limitations and requirements. 1LEED® is a registered trademark of U.S. Green Building Council. 20nly on product sold in Canada. 3Underwriters Laboratories Evaluation Service Evaluation Report. 4lnternational Code Council Evaluation Services Acceptance Criteria for Alternative Asphalt Shingles. All content on this site (including, without limitation, text, design, graphics, logos, icons, images, audio clips, downloads, interfaces, code and software, as well as the selection and arrangement thereof), is the exclusive property of and owned by Owens Corning, its licensors or its content providers and is protected by copyright, trademark and other applicable laws. View a list of Owens Corning Trademarks US (https://dcpd6wotaa0mb.cloudfront.net/owenscorning.com/assets/roofing/TrademarksOwensCorning Website-US- e086506cc0fff1 a5ce941 81 974c1 286cc727db3675401 504bef8d8718c607e00.pdf) https://www.owenscorning.com/roofing/shingles/trudefinition-duration#technical-docs 4/5 10/11/2016 Owens Corning +This image depicts Triple Layer Protection® and the amount of Triple Layer Protection may vary on a shingle -to -shingle basis. SureNail® Technology is proprietary with U.S. and foreign protection including U.S. Patent Nos. 6,471,812; 7,836,654; 8,156,704; 8,181,413; 8,240,102; 8,430,983; 8,607,521; 8,623,164; 8,752,351; 8,991,130; 9,121,178; and other patents pending. © 1996-2016 Owens Corning (/copyright) The color PINK is a registered trademark of Owens Corning. THE PINK PANTHER & © 1964-2016 Metro -Goldwyn -Mayer Studios Inc. All Rights Reserved. TruDefinition Duration Shingles ESTATE GRAY https://www.owenscorning.com/roofing/shingles/trudefinition-duration#technical-docs 5/5 OWENS CORNING INNOVATIONS FOR LIVING' I. Fiberglass -Based Asphalt Shingles & Accessories Guide Specifications PROJECT ARCHITECT RESPONSIBILITY: This is a general specification guide, intended to be used by experienced construction professionals, in conjunction with good construction practice and professional judgment. This guide is to aid in the creation of a complete building specification that is to be fully reviewed and edited by the architect of record (specifier). Sections of this guide should be included, edited, or omitted based on the requirements of a specific project. It is the responsibility of both the specifier and the purchaser to determine if a product or system is suitable for its intended use. Neither Owens Corning, nor any of its subsidiary or affiliated companies, assume any responsibility for the content of this specification guide relative to actual projects and specifically disclaim any and all liability for any errors or omissions in design, detail, structural capability, attachment details, shop drawings or other construction related details, whether based upon the information provided by Owens Corning or otherwise. SECTION 07 31 13 - FIBERGLASS -BASED ASPHALT SHINGLES & ACCESSORIES PART 1 GENERAL 1.1 SECTION INCLUDES A. Roof shingles and accessories including the following: 1. Fiberglass -based asphalt shingles. 2. Hip and ridge shingles. 3. Starter shingles. 4. Self -adhering ice and water barrier. 5. Shingle underlayment. 6. Attic ventilation. 7. Fasteners. 8. Metal flashing and trim. 1.2 RELATED SECTIONS **NOTE TO SPECIFIER** Delete and/or add other sections as required. A. Section 061000 - Rough Carpentry. B. Section 071300 — Sheet Waterproofing. C. Section 072400 - Roof and Deck Insulation; for insulation placed over roof decking. D. Section 076000 - Flashing and Sheet Metal; for snow guards, metal flashing and drip e flashing installed with shingles. E. Section 077200 - Roof Accessories, Skylights, Gutters, Downspouts. **NOTE TO SPECIFIER** Delete references from the list below that are not required. 1.3 REFERENCES FILE RECEIVED CITY OF TUKWILA OCT 112016 PERMIT CENTER ges, rRi. tpeFOR CODE COMPLIANCE APPROVED OCT 14 2016 A. ASTM International (ASTM): 1. ASTM A653/A653M - Standard Specification for Steel Sheet, Zinc Coated (Ga vanized o�if IrbrSi l lkiyrii2i Coated (Galvannealed) by the Hot -Dip Process. I BUILDING DIVISION 2. ASTM B209 - Standard Specification for Aluminum and Aluminum -Alloy Sheettwad,J.Ja 3. ASTM B370 — Standard Specification for Copper Sheet and Strip for Building Construction. 4. ASTM D226 - Standard Specification for Asphalt -Saturated Organic Felt Used in Roofing and Waterproofing. 5. ASTM D228 - Standard Test Method for Sampling, Testing, and Analysis of Asphalt Roll Roofing, Cap Sheets, and Shingles Used in Roofing and Waterproofing. 6. ASTM D1970 - Standard Specification for Self -Adhering Polymer Modified Bituminous Sheet Materials Used as Steep Roofing Underlayment for Ice Dam Protection. 7. ASTM D3018 - Standard Specification for Class A Asphalt Shingles Surfaced with Mineral Granules. 8. ASTM D3161 - Standard Test Method for Wind -Resistance of Asphalt Shingles (Fan -Induced Method). 9. ASTM D3462 - Standard Specification for Asphalt Shingles Made from Glass felt and Surfaced with Mineral Granules. i(p OWENS CORNING INNOVATIONS FOR LIVING` Fiberglass -Based Asphalt Shingles & Accessories Guide Specifications 10. ASTM D4869 - Standard Specification for Asphalt -Saturated Organic Felt Underlayment Used in Steep Slope Roofing. 11. ASTM D6381 - Standard Test Method for Measurement of Asphalt Shingle Mechanical Uplift Resistance. 12. ASTM D6757 — Standard Specification for Underlayment Felt Containing Inorganic Fibers Used in Steep - Slope Roofing. 13. ASTM D7158 - Standard Test Method for Wind Resistance of Sealed Asphalt Shingles (Uplift Force/Uplift Resistance Method). 14. ASTM E108 - Standard Test Methods for Fire Tests of Roof Coverings. 15. ASTM F1667 - Standard Specification for Driven Fasteners: Nails, Spikes, and Staples. B. Canadian Standards Association (CSA): CSA A123.5 - Asphalt Shingles Made from Glass Felt and Surfaced with Mineral Granules. Note: Applicable only to products sold for use in Canada. C. California Building Standards Commission (CBSC): 1. California Building Code, California Code of Regulations Title 24. D. Florida Building Commission (FBC): 1. Florida Building Code. 2. Florida Product Approvals. E. International Code Council (ICC): 1. International Residential Code (IRC). 2. International Building Code (IBC). 3. ICC -ES Evaluation Reports. 4. ICC -ES Acceptance Criteria. F. Underwriters Laboratories (UL): 1. UL 790 - Standard Test Methods for Fire Test of Roof Coverings. 2. UL 997 — Wind Resistance of Prepared Roof Covering Materials. 3. UL 2218 - Impact Resistance of Prepared Roof Covering Materials. 4. UL 2390 - Test Method for Wind Resistant Asphalt Shingles with Sealed Tabs. G. Underwriters Laboratories Evaluation Services (UL -ES): 1. UL -ES Evaluation Reports. H. Environmental Protection Agency (EPA): ENERGY STAR Rating System. I. Cool Roof Rating Council (CRRC): Product Rating Program. J. Miami -Dade County Building Code Compliance Office (BCCO), Product Control Division: Miami -Dade County Notice of Acceptance (NOA). K. Texas Department of Insurance (TDI): Product Listing. L. US Green Building Council (USGBC): Leadership in Energy and Environmental Design (LEED). 1.4 SUBMITTALS A. Submit under provisions of Section 01300. B. Product Data: Manufacturer's data sheets and detail drawings for each product to be used, including: 1. Preparation instructions and recommendations. 2. Storage and handling requirements and recommendations. 3. Product literature. 4. Installation methods. **NOTE TO SPECIFIER** Delete selection samples if colors have already been selected. C. Selection Samples: Two complete sets of samples, representing manufacturer's full range of available products and colors. D. Verification Samples: For each product and finish specified, two samples representing actual products and colors. rrinr INNOVATIONS FOR DYING` Fiberglass -Based Asphalt Shingles & Accessories Guide Specifications E. Copy of Warranty: For warranty specified in Par. 1.8 in this Section. 1.5 QUALITY ASSURANCE A. Manufacturer Qualifications: Provide all primary roofing products, including shingles, underlayment, leak barrier, and ventilation, by a single manufacturer. B. Installer Qualifications: 1. Installer shall follow Owens Corning Roofing and Asphalt published installation instructions. **NOTE TO SPECIFIER** Delete one of two options below. Select option based on desired warranty. 2. Installer shall be an Owens Coming Roofing Preferred Contractor as defined and certified by manufacturer. 3. Installer shall be an Owens Coming Roofing Platinum Preferred Contractor as defined and certified by manufacturer. 1.6 DELIVERY, STORAGE, AND HANDLING A. Deliver materials to site in manufacturer's unopened bundles with labels intact and legible. B. Store all products in manufacturer's unopened, labeled packaging until they are ready for installation. C. Handle and store materials on site to prevent damage. Store products in a covered, ventilated area, at temperature not more than 110 degrees Fahrenheit (43 degrees Celsius); do not store near steam pipes, radiators, or in direct sunlight. D. Store bundles on a flat surface. Do not stack product more than 2 pallets high. If stacking 2 pallets high, use separator boards to protect the shingles below. Store all rolls on end. E. Do not install underlayment or shingles on wet surfaces. F. Store and dispose of solvent -based materials in accordance with all federal, state and local regulations. G. For rooftop loading, lay shingle bundles flat. Do not bend over the ridge. 1.7 PROJECT CONDITIONS A. Maintain environmental conditions (temperature, humidity, and ventilation) within limits recommended by manufacturer for optimum results. Do not install systems under environmental conditions outside manufacturer's recommended limits. 1. Proceed with work only when existing and forecasted weather conditions will permit work to be performed in accordance with manufacturer's recommendations. 1.8 WARRANTY A. Manufacturer's Warranty: Provide to the Owner manufacturer's standard prorated warranty coverage for materials in the event of a material defect, including up to 10 years Tru Protection® coverage. Refer to actual warranty for complete details, limitations and requirements. B. Manufacturer's Extended Warranty: Provide to the Owner manufacturer's standard extended warranty coverage labor and materials in the event of a material defect. Refer to actual warranty for complete details, limitations and requirements. **NOTE TO SPECIFIER** Delete one of two options below. Select option based on desired warranty. 1. System Protection Roofing Limited Warranty includes up to 50 years of Tru Protection® (non -prorated) coverage on installed Owens Corning Roofing System products and labor. The length of the Tru Protection® coverage is based upon the shingle product installed on the field of the roof. Coverage can only be provided by a designated Owens Coming Roofing Preferred or Platinum Preferred Contractor. 2. Preferred Protection Roofing System Limited Warranty includes up to 50 years of Tru Protection® (non - prorated) coverage on installed Owens Corning Roofing System products and labor. The length of the Tru Protection® coverage is based upon the shingle product installed on the field of the roof. This warranty will also cover workmanship defects by the installer. Coverage can only be provided by a designated Owens Corning Roofing Preferred or Platinum Preferred Contractor. 3. Platinum Protection Roofing System Limited Warranty includes up to 50 years of Tru Protection® (non - prorated) coverage on installed Owens Corning Roofing System products and labor. The length of the Tru Protection® coverage is based upon the shingle product installed on the field of the roof. This warranty will Fiberglass -Based Asphalt Shingles & Accessories OWENS CORNING INNOVATIONS FOR LIVING` Guide Specifications also cover workmanship defects by the installer. Coverage can only be provided by a designated Owens Coming Roofing Platinum Preferred Contractor. PART 2 PRODUCTS 2.1 MANUFACTURERS A. Acceptable Manufacturer: Owens Coming Roofing and Asphalt, LLC. One Owens Coming Pkwy. Toledo, OH 43659. Toll Free: 1 -800 -ROOFING. Email: ocbuildingspec@owenscoming.com. Web: www.owenscominq.com. **NOTE TO SPECIFIER" Delete one of the following two paragraphs; coordinate with requirements of Division 1 Section on Product Options and Substitutions. B. Substitutions: Not permitted. C. Requests for substitutions will be considered in accordance with provisions of Section 01600. 2.2 ROOF SHINGLES **NOTE TO SPECIFIER** Delete roof shingle products from the list below that are not required. **NOTE TO SPECIFIER" Verify with the manufacturer regional product availability. A. Duration® Premium (Algae Resistant) Shingles: As manufactured by Owens Coming Roofing and Asphalt, LLC. 1. Nominal Size: 13-1/4 in (337 mm) by 39-3/8 in (1000 mm). 2. Exposure: 5-5/8 in (143 mm). 3. Shingles per Square: 64. 4. Bundles per Square: 4 bundles of 16 shingles. 5. Coverage per Square: 98.4 sq ft (9.1 sq m). 6. Color: As selected from manufacturer's full range. 7. Standards/Qualifications: ASTM D228, ASTM D3018 (Type 1), ASTM D3161 (Class F Wind Resistance), ASTM D3462, ASTM D7158 (Class H Wind Resistance), ASTM E108/UL 790 (Class A Fire Resistance), ICC -ES AC438, and UL ER2453-01. B. Duration® Premium (Non Algae Resistant) Shingles: As manufactured by Owens Corning Roofing and Asphalt, LLC. 1. Nominal Size: 13-1/4 in (337 mm) by 39-3/8 in (1000 mm). 2. Exposure: 5-5/8 in (143 mm). 3. Shingles per Square: 64. 4. Bundles per Square: 4 bundles of 16 shingles. 5. Coverage per Square: 98.4 sq ft (9.1 sq m). 6. Color: As selected from manufacturer's full range. 7. Standards/Qualifications: ASTM D228, ASTM D3018 (Type 1), ASTM D3161 (Class F Wind Resistance), ASTM D3462, ASTM D7158 (Class H Wind Resistance), ASTM E108/UL 790 (Class A Fire Resistance), ICC -ES AC438, and UL ER2453-01. C. Duration® Premium Cool (Algae Resistant) Shingles: As manufactured by Owens Corning Roofing and Asphalt, LLC. 1. Nominal Size: 13-1/4 in (337 mm) by 39-3/8 in (1000 mm). 2. Exposure: 5-5/8 in (143 mm). 3. Shingles per Square: 64. 4. Bundles per Square: 4 bundles of 16 shingles. 5. Coverage per Square: 98.4 sq ft (9.1 sq m). 6. Color: As selected from manufacturer's full range. 7. Standards/Qualifications: ASTM D228, ASTM D3018 (Type 1), ASTM D3161 (Class F Wind Resistance), ASTM D3462, ASTM D7158 (Class H Wind Resistance), ASTM E108/UL 790 (Class A Fire Resistance), meets the ENERGY STAR® requirements for initial solar reflectance of 0.25 and 3 -year aged solar reflectance of 0.15, 2010 California Building Energy Efficiency Standards, Title 24, Part 6 requirements, Rated by the Cool Roof Rating Council (CRRC), Florida Product Approval (FL10674), ICC -ES AC438, and UL ER2453-01. OWENS CORNING INNOVATIONS fOR IIVING` Fiberglass -Based Asphalt Shingles & Accessories Guide Specifications D. TruDefinition® Duration® (Algae Resistant) Shingles: As manufactured by Owens Coming Roofing and Asphalt, LLC. 1. Nominal Size: 13-1/4 in (337 mm) by 39-3/8 in (1000 mm). 2. Exposure: 5-5/8 in (143 mm). 3. Shingles per Square: 64. 4. Bundles per Square: 3 bundles of 20 or 22 shingles. 5. Coverage per Square: 98.4 sq ft (9.1 sq m). 6. Color: As selected from manufacturer's full range. 7. Standards/Qualifications: ASTM D228, ASTM D3018 (Type 1), ASTM D3161 (Class F Wind Resistance), ASTM D3462, ASTM D7158 (Class H Wind Resistance), ASTM E108/UL 790 (Class A Fire Resistance), CSA A123.5, Florida Product Approval (FL10674), Miami -Dade County Product Approval (12-0309.01), ICC -ES AC438, and UL ER2453-01. E. TruDefinition® Duration® (Non Algae Resistant) Shingles: As manufactured by Owens Coming Roofing and Asphalt, LLC. 1. Nominal Size: 13-1/4 in (337 mm) by 39-3/8 in (1000 mm). 2. Exposure: 5-5/8 in (143 mm). 3. Shingles per Square: 64. 4. Bundles per Square: 3 bundles of 20 or 22 shingles. 5. Coverage per Square: 98.4 sq ft (9.1 sq m). 6. Color: As selected from manufacturer's full range. 7. Standards/Qualifications: ASTM D228, ASTM D3018 (Type 1), ASTM D3161 (Class F Wind Resistance), ASTM D3462, ASTM D7158 (Class H Wind Resistance), ASTM E108/UL 790 (Class A Fire Resistance), ICC -ES AC438, and UL ER2453-01. F. TruDefinition® Duration® Designer Color Collections (Algae Resistant) Shingles: As manufactured by Owens Coming Roofing and Asphalt, LLC. 1. Nominal Size: 13-1/4 in (337 mm) by 39-3/8 in (1000 mm). 2. Exposure: 5-5/8 in (143 mm). 3. Shingles per Square: 64. 4. Bundles per Square: 3 bundles of 20 or 22 shingles. 5. Coverage per Square: 98.4 sq ft (9.1 sq m). 6. Color: As selected from manufacturer's full range. 7. Standards/Qualifications: ASTM D228, ASTM D3018 (Type 1), ASTM D3161 (Class F Wind Resistance), ASTM D3462, ASTM D7158 (Class H Wind Resistance), ASTM E108/UL790 (Class A Fire Resistance), CSA A123.5, Florida Product Approval (FL10674), Miami -Dade County Product Approval (12-0309.01), ICC -ES AC438, and UL ER2453-01. G. TruDefinition® Duration® Designer Color Collections (Non Algae Resistant) Shingles: As manufactured by Owens Coming Roofing and Asphalt, LLC. 1. Nominal Size: 13-1/4 in (337 mm) by 39-3/8 in (1000 mm). 2. Exposure: 5-5/8 in (143 mm). 3. Shingles per Square: 64. 4. Bundles per Square: 3 bundles of 20 or 22 shingles. 5. Coverage per Square: 98.4 sq ft (9.1 sq m). 6. Color: As selected from manufacturer's full range. 7. Standards/Qualifications: ASTM D228, ASTM D3018 (Type 1), ASTM D3161 (Class F Wind Resistance), ASTM D3462, ASTM D7158 (Class H Wind Resistance), ASTM E108/UL790 (Class A Fire Resistance), ICC -ES AC438, and UL ER2453-01. H. TruDefinition® Duration MAXTM' (Non Algae Resistant) Shingles: As manufactured by Owens Coming Roofing and Asphalt, LLC. 1. Nominal Size: 13-1/4 in (337 mm) by 39-3/8 in (1000 mm). 2. Exposure: 5-5/8 in (143 mm). 3. Shingles per Square: 64. 4. Bundles per Square: 4 bundles of 16 shingles. 5. Coverage per Square: 98.4 sq ft (9.1 sq m). 6. Color: As selected from manufacturer's full range. 7. Standards/Qualifications: ASTM D228, ASTM D3018 (Type 1), ASTM D3161 (Class F Wind Resistance), ASTM D3462, ASTM D7158 (Class H Wind Resistance), ASTM E108/UL 790 (Class A Fire Resistance), ICC -ES AC438, and UL ER2453-01. rENS CORNING INNOVATIONS FOR LIVING' Fiberglass -Based Asphalt Shingles & Accessories Guide Specifications TruDefinition® Duration STORM® (Algae Resistant) Shingles: As manufactured by Owens Coming Roofing and Asphalt, LLC. 1 Nominal Size: 13-1/4 in (337 mm) by 39-3/8 in (1000 mm). 2. Exposure: 5-5/8 in (143 mm). 3. Shingles per Square: 64. 4. Bundles per Square: 3 bundles of 20 or 22 shingles. 5. Coverage per Square: 98.4 sq ft (9.1 sq m). 6. Color: As selected from manufacturer's full range. 7. Standards/Qualifications: ASTM D228, ASTM D3018 (Type 1), ASTM D3161 (Class F Wind Resistance), ASTM D3462, ASTM D7158 (Class H Wind Resistance), ASTM E108/UL 790 (Class A Fire Resistance), UL 2218 (Class 4 Impact Resistance), CSA A123.5, ICC -ES AC438, and UL ER2453-01. J. TruDefinition® Oakridge® (Algae Resistant) Shingles: As manufactured by Owens Coming Roofing and Asphalt, LLC. 1. Nominal Size: 13-1/4 in (337 mm) by 39-3/8 in (1000 mm). 2. Exposure: 5-5/8 in (143 mm). 1. Shingles per Square: 64. 2. Bundles per Square: 3. 3. Coverage per Square: 98.4 sq ft (9.1 sq m). 4. Color: As selected from manufacturer's full range. 5. Standards/Qualifications: ASTM D228, ASTM D3018 (Type 1), ASTM D3161 (Class F Wind Resistance), ASTM D3462, ASTM D7158 (Class H Wind Resistance), ASTM E108/UL 790 (Class A Fire Resistance), Florida Product Approval (FL10674), Miami -Dade County Product Approval (12-0430.01), ICC -ES AC438, and UL ER2453-01. K. TruDefinition® WeatherGuard® (Algae Resistant) Shingles: As manufactured by Owens Corning Roofing and Asphalt, LLC. 1. Nominal Size: 13-1/4 in (337 mm) by 39-3/8 in (1000 mm). 2. Exposure: 5-5/8 in (143 mm). 1. Shingles per Square: 64. 2. Bundles per Square: 3. 3. Coverage per Square: 98.4 sq ft (9.1 sq m). 4. Color: As selected from manufacturer's full range. 5. Standards/Qualifications: ASTM D228, ASTM D3018 (Type 1), ASTM D3161 (Class F Wind Resistance), ASTM D3462, ASTM D7158 (Class H Wind Resistance), ASTM E108/UL 790 (Class A Fire Resistance), UL 2218 (Class 4 Impact Resistance), ICC -ES AC438, and UL ER2453-01. L. Oakridge® (Non Algae Resistant) Shingles: As manufactured by Owens Corning Roofing and Asphalt, LLC. 1. Nominal Size: 13-1/4 in (337 mm) by 39-3/8 in (1000 mm). 2. Exposure: 5-5/8 in (143 mm). 3. Shingles per Square: 64. 4. Bundles per Square: 3 bundles of 20 or 22 shingles. 5. Coverage per Square: 98.4 sq ft (9.1 sq m). 6. Color: As selected from manufacturer's full range. 7. Standards/Qualifications: ASTM D228, ASTM D3018 (Type 1), ASTM D3161 (Class F Wind Resistance), ASTM D3462, ASTM D7158 (Class H Wind Resistance), ASTM E108/UL 790 (Class A Fire Resistance), CSA A123.5, ICC -ES AC438, and UL ER2453-01. Shasta White Color meets ENERGY STAR requirements for initial solar reflectance of 0.25 and 3 -year aged solar reflectance of 0.15. M. Oakridge® (Algae Resistant) Shingles: As manufactured by Owens Corning Roofing and Asphalt, LLC. 1. Nominal Size: 13-1/4 in (337 mm) by 39-3/8 in (1000 mm). 2. Exposure: 5-5/8 in (143 mm). 3. Shingles per Square: 64. 4. Bundles per Square: 3 bundles of 20 or 22 shingles. 5. Coverage per Square: 98.4 sq ft (9.1 sq m). 6. Color: As selected from manufacturer's full range. 7. Standards/Qualifications: ASTM D228, ASTM D3018 (Type 1), ASTM D3161 (Class F Wind Resistance), ASTM D3462, ASTM D7158 (Class H Wind Resistance), ASTM E108/UL 790 (Class A Fire Resistance), CSA A123.5, ICC -ES AC438, UL ER2453-01, Florida Product Approval (FL10674), and Miami -Dade County Product Approval (12-0430.01). Shasta White Color meets ENERGY STAR requirements for initial solar reflectance of 0.25 and 3 -year aged solar reflectance of 0.15. N. Berkshire® (Algae Resistant) Shingles: As manufactured by Owens Corning Roofing and Asphalt, LLC. 1. Nominal Size: 18-3/4 in (476 mm) by 38 in (965 mm). OWENS CORNING INNOYATIONS FOR HYING` Fiberglass -Based Asphalt Shingles & Accessories Guide Specifications 2. Exposure: 8-3/8 in. (213 mm). 3. Shingles per Square: 45. 4. Bundles per Square: 5 bundles of 9 shingles. 5. Coverage per Square: 99.5 sq ft (9.2 sq m). 6. Color: As selected from manufacturer's full range. 7. Standards/Qualifications: ASTM D228, ASTM D3018 (Type 1), ASTM D3161 (Class F Wind Resistance), ASTM D3462, ASTM D7158 (Class H Wind Resistance), ASTM E108/UL 790 (Class A Fire Resistance), ICC -ES AC438, UL ER2453-01, Florida Product Approval (FL10674), and Miami -Dade County Product Approval (10-0817.09). O. Devonshire T*' (Algae Resistant) Shingles: As manufactured by Owens Coming Roofing and Asphalt, LLC. 1. Nominal Size: 13-1/4 in (337 mm) by 40 in (1016 mm). 2. Exposure: 5-5/8 in. (143 mm). 3. Shingles per Square: 64. 4. Bundles per Square: 3 bundles of 21 or 22 shingles. 5. Coverage per Square: 100 sq ft (9.3 sq m). 6. Color: As selected from manufacturer's full range. 7. Standards/Qualifications: ASTM D228, ASTM D3018 (Type 1), ASTM D3161 (Class F Wind Resistance), ASTM D3462, ASTM D7158 (Class H Wind Resistance), ASTM E108/UL 790 (Class A Fire Resistance), ICC -ES AC438, UL ER2453-01, and Florida Product Approval (FL10674). P. WeatherGuard® HP (Algae Resistant) Shingles: As manufactured by Owens Coming Roofing and Asphalt, LLC. 1. Nominal Size: 13-1/4 in (337 mm) by 39-3/8 in (1000 mm). 2. Exposure: 5-5/8 in (143 mm). 3. Shingles per Square: 64. 4. Bundles per Square: 3 bundles of 20 or 22 shingles. 5. Coverage per Square: 98.4 sq ft (9.1 sq m). 6. Color: As selected from manufacturer's full range. 7. Standards/Qualifications: ASTM D228, ASTM D3018 (Type 1), ASTM D3161 (Class F Wind Resistance), ASTM D3462, ASTM D7158 (Class H Wind Resistance), ASTM E108/UL 790 (Class A Fire Resistance), ICC -ES AC438, UL ER2453-01, Florida Product Approval (FL10674), and Miami -Dade County Product Approval (10-0817.10). Q. Woodmoor® (Algae Resistant) Shingles: As manufactured by Owens Coming Roofing and Asphalt, LLC. 1. Nominal Size: 14-1/4 in (362 mm) by 40 in (1016 mm). 2. Exposure: 4 in (102 mm). 3. Shingles per Square: 90. 4. Bundles per Square: 6 bundles of 15 shingles. 5. Coverage per Square: 100.0 sq ft (9.3 sq m). 6. Color: As selected from manufacturer's full range. 7. Standards/Qualifications: ASTM D228, ASTM D3018 (Type 1), ASTM D3161 (Class F Wind Resistance), ASTM D3462, ASTM D7158 (Class H Wind Resistance), ASTM E108/UL 790 (Class A Fire Resistance), CSA A123.5, ICC -ES AC438, and UL ER2453-01. R. Woodcrest® (Algae Resistant) Shingles: As manufactured by Owens Corning Roofing and Asphalt, LLC. 1. Nominal Size: 14-1/4 in (362 mm) by 40 in (1016 mm). 2. Exposure: 4 in (102 mm). 3. Shingles per Square: 90. 4. Bundles per Square: 6 bundles of 15 shingles. 5. Coverage per Square: 100.0 sq ft (9.3 sq m). 6. Color: As selected from manufacturer's full range. 7. Standards/Qualifications: ASTM D228, ASTM D3018 (Type 1), ASTM D3161 (Class F Wind Resistance), ASTM D3462, ASTM D7158 (Class H Wind Resistance), ASTM E108/UL 790 (Class A Fire Resistance), CSA A123.5, ICC -ES AC438, and UL ER2453-01. S. Supreme® (Algae Resistant) Shingles: As manufactured by Owens Coming Roofing and Asphalt, LLC. 1. Nominal Size: 12 in (305 mm) by 36 in (914 mm). 2. Exposure: 5 in (127 mm). 3. Shingles per Square: 80. 4. Bundles per Square: 3 bundles of 26, 27, 27 shingles. 5. Coverage per Square: 100.0 sq ft (9.3 sq m). 6. Color: As selected from manufacturer's full range. rg11/111T, INNOVATIONS FOR DYING` Fiberglass -Based Asphalt Shingles & Accessories Guide Specifications 7. Standards/Qualifications: ASTM D228, ASTM 03018 (Type 1), ASTM D3161 (Class F Wind Resistance), ASTM D3462, ASTM D7158 (Class H Wind Resistance), ASTM E108/UL 790 (Class A Fire Resistance), ICC -ES AC438, UL ER2453-01, Florida Product Approval (FL10674), and Miami -Dade County Product Approval (12-1204.03). T. Supreme® (Non Algae Resistant) Shingles: As manufactured by Owens Coming Roofing and Asphalt, LLC. 1. Nominal Size: 12 in (305 mm) by 36 in (914 mm). 2. Exposure: 5 in (127 mm). 3. Shingles per Square: 80. 4. Bundles per Square: 3 bundles of 26, 27, 27 shingles. 5. Coverage per Square: 100.0 sq ft (9.3 sq m). 6. Color: As selected from manufacturer's full range. 7. Standards/Qualifications: ASTM D228, ASTM D3018 (Type 1), ASTM D3161 (Class F Wind Resistance), ASTM D3462, ASTM D7158 (Class H Wind Resistance), ASTM E108/UL 790 (Class A Fire Resistance), ICC -ES AC438, and UL ER2453-01. U. Supreme® (Algae Resistant) (Metric) Shingles: As manufactured by Owens Coming Roofing and Asphalt, LLC. 1. Nominal Size: 13-1/4 in (337 mm) by 39-3/8 in (1000 mm). 2. Exposure: 5-5/8 in (143 mm). 3. Shingles per Square: 65. 4. Bundles per Square: 3 bundles of 21, 22, 22 shingles. 5. Coverage per Square: 100.0 sq ft (9.3 sq m). 6. Color: As selected from manufacturer's full range. 7. Standards/Qualifications: ASTM D228, ASTM D3018 (Type 1), ASTM D3161 (Class F Wind Resistance), ASTM D3462, ASTM D7158 (Class H Wind Resistance), ASTM E108/UL 790 (Class A Fire Resistance), CSA A123.5, ICC -ES AC438, and UL ER2453-01. V. Supreme® (Non Algae Resistant) (Metric) Shingles: As manufactured by Owens Corning Roofing and Asphalt, LLC. 1. Nominal Size: 13-1/4 in (337 mm) by 39-3/8 in (1000 mm). 2. Exposure: 5-5/8 in (143 mm). 3. Shingles per Square: 65. 4. Bundles per Square: 3 bundles of 21, 22, 22 shingles. 5. Coverage per Square: 100.0 sq ft (9.3 sq m). 6. Color: As selected from manufacturer's full range. 7. Standards/Qualifications: ASTM D228, ASTM D3018 (Type 1), ASTM D3161 (Class F Wind Resistance), ASTM D3462, ASTM D7158 (Class H Wind Resistance), ASTM E108/UL 790 (Class A Fire Resistance), ICC -ES AC438, and UL ER2453-01. W. Classic® (Non Algae Resistant) Shingles: As manufactured by Owens Corning Roofing and Asphalt, LLC. 1. Nominal Size: 12 in (305 mm) by 36 in (914 mm). 2. Exposure: 5 in (127 mm). 3. Shingles per Square: 80. 4. Bundles per Square: 3 bundles of 26, 27, 27 shingles. 5. Coverage per Square: 100.0 sq ft (9.3 sq m). 6. Color: As selected from manufacturer's full range. 7. Standards/Qualifications: ASTM D228, ASTM D3018 (Type 1), ASTM D3161 (Class F Wind Resistance), ASTM D3462, ASTM D7158 (Class H Wind Resistance), ASTM E108/UL 790 (Class A Fire Resistance), ICC -ES AC438, and UL ER2453-01. X. Mineral Surface Roll (Non Algae Resistant): As manufactured by Owens Coming Roofing and Asphalt, LLC. 1. Nominal Size: 36 in (914 m) by 36 in (914 mm). 2. Exposure: 34 in (864 mm). 3. Rolls per Square: 1. 4. Coverage per Square: 100.0 sq ft (9.3 sq m). 5. Standards/Qualifications: ASTM E108/UL 790 (Class C Fire Resistance), and Florida Product Approval (FL12221). 2.3 HIP AND RIDGE SHINGLES Provide hip and ridge shingles color formulated to complement field of roof. **NOTE TO SPECIFIER** Delete hip and ridge shingle products from the list below that are not required. OWENS CORNING INNOVATIONS FOR LIVING` Fiberglass -Based Asphalt Shingles & Accessories Guide Specifications **NOTE TO SPECIFIER** Verify with the manufacturer regional product availability. A. RIZERidge® Hip and Ridge (Algae Resistant) Shingles with Sealant: As manufactured by Owens Coming Roofing and Asphalt, LLC. 1. Foldable design provides multi -layered dimension along hips and ridges. 2. Nominal Size: 12 in (305 mm) by 36 in (914 mm) with 6 in (152 mm) exposure. 3. Piece Size: 12 in (305 mm) by 12 in (305 mm). 4. Standards/Qualifications: ASTM D228, ASTM 03018 (Type 1), ASTM D3161 (Class F Wind Resistance), ASTM 03462, ASTM E108/UL 790 (Class A Fire Resistance), ICC -ES AC438, UL ER2453-01, and Florida Product Approval (FL10674). B. High Ridge Hip and Ridge (Algae Resistant) Shingles with Sealant: As manufactured by Owens Corning Roofing and Asphalt, LLC. 1. Layered construction adds performance and dimension to the hip and ridge. 2. Nominal Size: 12 in (305 mm) by 12 in (305 mm) with 8 in (203 mm) exposure. 3. Standards/Qualifications: ASTM D228, ASTM D3018 (Type 1), ASTM D3161 (Class F Wind Resistance), ASTM D3462, ASTM E108/UL 790 (Class A Fire Resistance), ICC -ES AC438, UL ER2453-01, Florida Building Code Approval (FL10674), and Miami -Dade County Product Approval (10-0817.08). C. High Ridge Hip and Ridge (Non Algae Resistant) Shingles with Sealant: As manufactured by Owens Coming Roofing and Asphalt, LLC. 1. Layered construction adds performance and dimension to the hip and ridge. 2. Nominal Size: 12 in (305 mm) by 12 in (305 mm) with 8 in (203 mm) exposure. 3. Standards/Qualifications: ASTM D228, ASTM D3018 (Type 1), ASTM D3161 (Class F Wind Resistance), ASTM D3462, ASTM E108/UL 790 (Class A Fire Resistance), ICC -ES AC438, and UL ER2453-01. D. DecoRidge® Hip and Ridge (Non Algae Resistant) Shingles with Sealant 1. Durable, heavyweight laminate construction with SBS -modified asphalt provides maximum dimension and style to the hip and ridge. 2. Nominal Size: 11-1/2 in (292 mm) by 8 in (203 mm) and 11-1/2 in (292 mm) by 10 in (254 mm) with 8 in (203 mm) exposure. 3. Standards/Qualifications: ASTM D228, ASTM D3018 (Type 1), ASTM D3161 (Class F Wind Resistance), ASTM D3462, ASTM E108/UL 790 (Class A Fire Resistance), and CSA A123.5. E. ProEdge® Hip and Ridge (Algae Resistant) Shingles: As manufactured by Owens Coming Roofing and Asphalt, LLC. 1. Perforated shingles with factory installed cutouts designed for fast and easy installation. 2. Nominal Size: 12 in (305 mm) by 36 in (914 mm) with 6 in (152 mm) exposure. 3. Piece Size: 12 in (305 mm) by 12 in (305 mm). 4. Standards/Qualifications: ASTM D228, ASTM D3018 (Type 1), ASTM D3161 (Class F Wind Resistance), ASTM D3462, ASTM E108/UL 790 (Class A Fire Resistance), CSA A123.5, ICC -ES AC438, UL ER2453- 01, Florida Product Approval (FL10674), and Miami -Dade County Product Approval (12-0725.01). F. ProEdge® Hip and Ridge (Non Algae Resistant) Shingles: As manufactured by Owens Corning Roofing and Asphalt, LLC. 1. Perforated shingles with factory installed cutouts designed for fast and easy installation. 2. Nominal Size: 12 in (305 mm) by 36 in (914 mm) with 6 in (152 mm) exposure. 3. Piece Size: 12 in (305 mm) by 12 in (305 mm). 4. Standards/Qualifications: ASTM D228, ASTM D3018 (Type 1), ASTM D3161 (Class F Wind Resistance), ASTM D3462, ASTM E108/UL 790 (Class A Fire Resistance), ICC -ES AC438, and UL ER2453-01. G. ProEdge® Hip and Ridge (Algae Resistant) (Metric) Shingles: As manufactured by Owens Coming Roofing and Asphalt, LLC. 1. Perforated shingles with factory installed cutouts designed for fast and easy installation. 2. Nominal Size: 13-1/4 in (337 mm) by 39-3/8 in (1000 mm) with 6-5/8 in (168 mm) exposure. 3. Piece Size: 9-27/32 in (250 mm) by 13-1/4 in (337 mm). 4. Standards/Qualifications: ASTM D228, ASTM 03018 (Type 1), ASTM D3161 (Class F Wind Resistance), ASTM D3462, ASTM E108/UL 790 (Class A Fire Resistance), CSA A123.5, ICC -ES AC438, and UL ER2453-01. H. ProEdge STORM® Hip and Ridge Impact Resistant (Algae Resistant) Shingles: As manufactured by Owens Coming Roofing and Asphalt, LLC. 1. Perforated design for easy installation offering Class 4 impact resistance. 2. Nominal Size: 12 in (305 mm) by 36 in (914 mm) with 6 in (152 mm) exposure. OWENS CORNING INNOVATIONS FOR DYING` Fiberglass -Based Asphalt Shingles & Accessories Guide Specifications 3. Piece Size: 12 in (305 mm) by 12 in (305 mm). 4. Standards/Qualifications: ASTM D228, ASTM D3018 (Type 1), ASTM D3161 (Class F Wind Resistance), ASTM D3462, ASTM E108/UL 790 (Class A Fire Resistance), UL 2218 (Class 4 Impact Resistance), CSA A123.5, ICC -ES AC438, and UL ER2453-01. Berkshire® Hip and Ridge (Algae Resistant) Shingles: As manufactured by Owens Coming Roofing and Asphalt, LLC. 1. Layered construction adds performance and dimension to the hip and ridge. 2. Nominal Size: 12 in (305 mm) by 12 in (305 mm) with 8 in (203 mm) exposure. 3. Standards/Qualifications: ASTM D228, ASTM D3018 (Type 1), ASTM D3161 (Class F Wind Resistance), ASTM D3462, ASTM E108/UL 790 (Class A Fire Resistance), CSA A123.5, ICC -ES AC438, UL ER2453- 01, Florida Product Approval (FL10674), and Miami -Dade County Product Approval (10-0817.08). J. WeatherGuard® HP Hip and Ridge Impact Resistant (Algae Resistant) Shingles: As manufactured by Owens Coming Roofing and Asphalt, LLC. 1. Perforated design for easy installation offering Class 4 impact resistance. 2. Nominal Size: 12 in (305 mm) by 36 in (914 mm) with 6 in (152 mm) exposure. 3. Piece Size: 12 in (305 mm) by 12 in (305 mm). 4. Standards/Qualifications: ASTM D228, ASTM D3018 (Type 1), ASTM D3161 (Class F Wind Resistance), ASTM D3462, ASTM E108/UL 790 (Class A Fire Resistance), UL 2218 (Class 4 Impact Resistance), UL ER2453-01, and Florida Product Approval (FL10674). 2.4 STARTER SHINGLES **NOTE TO SPECIFIER** Delete starter shingle products from the list below that are not required. **NOTE TO SPECIFIER** Verify with the manufacturer regional product availability. A. Starter Shingle Roll: As manufactured by Owens Corning Roofing and Asphalt, LLC. 1. Self -adhering, starter course. Each strip measures 7-1/5 in (191 mm) tall by 33-2/5 ft (10.1 m) wide. 2. Standards/Qualifications: CCMC 13403-R. B. Starter Strip Shingle: As manufactured by Owens Corning Roofing and Asphalt, LLC. 1. Nail applied starter course. Individual starter shingle is 6-5/8 in (168 mm) by 39-3/8 in (1000 mm). 2. Standards/Qualifications: ASTM D3462, ASTM D3161 (Class F Wind Resistance), ASTM E108/UL 790 (Class A Fire Resistance), CSA A123.5, ICC -ES AC438, UL ER2453-01, and Florida Product Approval (FL10674). C. Starter Strip PLUS: As manufactured by Owens Coming Roofing and Asphalt, LLC. 1. Nail applied starter course. Individual starter shingle is 7-3/4 in (197 mm) by 39-3/8 in (1000 mm). 2. Standards/Qualifications: ASTM D3462, ASTM D3161 (Class F Wind Resistance), ASTM E108/UL 790 (Class A Fire Resistance), ICC -ES AC438, UL ER2453-01, Florida Product Approval (FL10674), and Miami -Dade County Product Approval (09-0915.12). D. WoodStart® Starter Shingle: As manufactured by Owens Corning Roofing and Asphalt, LLC. 1. Nail applied starter course. Nominal Size is 13-3/8 in (340 mm) by 40 in (1016 mm). 2. Standards/Qualifications: ASTM D3462, ASTM D3161 (Class F Wind Resistance), ASTM E108/UL 790 (Class A Fire Resistance), ICC -ES AC438, and UL ER2453-01. 2.5 SELF -ADHERING ICE AND WATER BARRIER **NOTE TO SPECIFIER** Delete self -adhering ice and water barrier products from the list below that are not required. **NOTE TO SPECIFIER** Verify with the manufacturer regional product availability. A. WeatherLock® Mat: As manufactured by Owens Coming Roofing and Asphalt, LLC. 1. Mat -faced skid resistant surface, self -adhering, self sealing, bituminous ice and water barrier. 2. Roll Width: 36 in (914 mm). 3. Selvage: 3 in (76 mm). 4. Standards/Qualifications: ASTM D1970, ASTM E108/UL 790 (Class A Fire Resistance), ICC -ESR 1783, CCMC 13403-R, Florida Product Approval (FL9777), and Miami -Dade County Product Approval (12- 1114.01). B. WeatherLock® G: As manufactured by Owens Corning Roofing and Asphalt, LLC. 1. Granule skid resistant surface, self -adhering, self sealing, bituminous ice and water barrier. 2. Roll Width: 36 in (914 mm). 3. Selvage: 3 in (76 mm). OWENS CORNING INNOVATIONS FOR DYING Fiberglass -Based Asphalt Shingles & Accessories Guide Specifications 4. Standards/Qualifications: ASTM D1970, ASTM E108/UL 790 (Class A Fire Resistance), ICC -ESR 1783, CCMC 13403-R, Florida Product Approval (FL9777), and Miami -Dade County Approval (12-1114.01). C. WeatherLock® Cold Climate: As manufactured by Owens Coming Roofing and Asphalt, LLC. 1. Granule skid resistant surface, self -adhering, self sealing, bituminous ice and water barrier. Designed for low temperature adhesion. 2. Roll Width: 36 in (914 mm). 3. Selvage: 3 in (76 mm). 4. Standards/Qualifications: ASTM D1970, ASTM E108/UL 790 (Class A Fire Resistance), CCMC 13403-R, and ICC -ESR 1783. D. WeatherLock® Flex: As manufactured by Owens Coming Roofing and Asphalt, LLC. 1. Cross laminated poly surface with skid resistant traction surface, self -adhering, self sealing, bituminous ice and water barrier. 2. Roll Width: 36 in (914 mm). 3. Selvage: 3 in (76 mm). 4. Standards/Qualifications: ASTM D1970, ASTM E108/UL 790 (Class A Fire Resistance), CCMC 13403-R, and ICC -ESR 1783. E. WeatherLock® Specialty Tile and Metal: As manufactured by Owens Coming Roofing and Asphalt, LLC. 1. Polyester surface with skid resistant traction surface, self -adhering, self sealing, bituminous ice and water barrier. 2. Thermally stable in high temperatures up to 260 degrees Fahrenheit (126 degrees Celsius). 3. Designed for use with mechanically fastened tile systems. 4. Roll Width: 36 in (914 mm). 5. Selvage: 3 in (76 mm). 6. Standards/Qualification: ASTM D1970, ASTM E108/UL 790 (Class A Fire Resistance), ICC -ESR 1783, CCMC 13403-R, Florida Product Approval (FL13029), and Miami -Dade County Product Approval (12- 0309.03). 2.6 SHINGLE UNDERLAYMENT **NOTE TO SPECIFIER** Delete shingle underlayment products from the list below that are not required. **NOTE TO SPECIFIER** Verify with the manufacturer regional product availability. A. Fiberglas® Reinforced Felt Underlayment. 1. Wrinkle resistant, water resistant, breather type cellulose/glass fiber composite roofing underlayment. 2. Roll Width: 36 in (914 mm). 3. Roll Length: 141.5 ft (43.1 m). 4. Coverage Per Roll: 4 roof squares. 5. Standards/Qualifications: ASTM D226 (Type II), ASTM D4869 (Type IV), ASTM D6757, and Florida Product Approval (FL12536). B. Deck Defense® High Performance Roof Underlayment. 1. Weather -shedding synthetic polyolefin barrier. 2. Roll Width: 48 in (1219 mm). 3. Roll Length: 125 ft (38.1 m) and 250 ft (76.2 m). 4. Coverage Per Roll: 5 and 10 roof squares. 5. Standards/Qualification: ASTM E108/UL 790 (Class A Fire Resistance), ICC -ESR 3229, CAN/CSA A220.1 Series -06, Florida Product Approval (FL14299), and Miami -Dade County Product Approval (11-0912.05). 2.7 ATTIC VENTILATION **NOTE TO SPECIFIER** Delete attic ventilation products from the list below that are not required. **NOTE TO SPECIFIER** Verify with the manufacturer regional product availability. A. VentSure® Rigid Roll Ridge Vent with Weather PROtector® Moisture Barrier. 1. Shingle -over, low profile ridge vents with Weather PROtector® Moisture Barrier allows the passage of hot and/or moisture -laden air from attics, while prohibiting snow infiltration. 2. Provides 12.5 sq in (8200 sq mm) NFVA per lineal foot. 3. Available in 20 ft (6.1 m) rolls in three different widths (regional availability): 7 in (178 mm), 9 in (229 mm), and 11-1/4 in (286 mm). 4. Suitable on roofs with a pitch from 2:12 to 20:12. 5. Standards/Qualifications: ICC -ESR 2664, Passes Wind -Driven Rain with 8.8 in (224 mm) of rain at 110 mph (177 km/h), and Snow Infiltration at 35 mph (56 km/h) and 70 mph (112 km/h) Tests, Florida Product Approval (FL10758), and Miami -Dade County Product Approval (12-0309.02). OWENS CORNING INNOVATIONS TOR LIVING` Fiberglass -Based Asphalt Shingles & Accessories Guide Specifications B. VentSure® 4 ft (1.2 m) Strip Heat and Moisture Ridge Vent, 12 in width (305 mm). 1. Shingle -over, polypropylene ridge ventilator designed to work with eave/soffit intake ventilation to maximize the flow of cool, fresh air through the roof and attic structure. 2. Patent -pending corrugated ridge design and interlocking feature for additional flexibility and strength 3. Provides 20 sq in (12900 sq mm) NFVA per lineal foot. 4. Optional filter provides added protection against wind -driven rain and snow infiltration. 5. 4 ft (1.2 m) strip is 15 in (381 mm) wide and 1 in (25 mm) high, with a shingle -over width of 12 in (305 mm). 6. Suitable on roofs with a pitch from 3:12 to 6:12. 7. Standards/Qualifications: ICC -ESR 3007, Passes Wind -Driven Rain with 8-4/5 in (224 mm) of rain at 110 mph (177 km/h), Florida Product Approval (FL10758), Miami -Dade County Product Approval (09-1019.03), and TDI listed for usage in Texas Coastal Regions (RV -47). C. VentSure® 4 ft (1.2 m) Strip Heat and Moisture Ridge Vent, 8 in (203 mm) and 10 in (254 mm) width. 1. Shingle -over, polypropylene ridge ventilator designed to work with eave/soffit intake ventilation to maximize the flow of cool, fresh air through the roof and attic structure. 2. Patent -pending corrugated ridge design and interlocking feature for additional flexibility and strength. 3. Provides 18 sq in (11600 sq mm) NFVA per lineal foot. 4. Optional filter provides added protection against wind -driven rain and snow infiltration. 5. 4 ft (1.2 m) strip is available in 8 in (203 mm) and 10 in (254 mm) shingle -over widths that are 1 in (25 mm) high and overall product width is 11.43 in (290 mm) and 13.28 in (337 mm), respectively. 6. Suitable on roofs with a pitch from 3:12 to 16:12. 7. Standards/Qualifications: ICC -ESR 3007, Passes Wind -Driven Rain with 8-4/5 in (224 mm) of rain at 110 mph (177 km/h), Florida Product Approval (FL10758.1), Miami -Dade County Product Approval (09- 1019.03), and TDI listed for usage in Texas Coastal Regions (RV -47). D. VentSure® Metal Slant Back Roof Vent 1. Rooftop mounted, slant -back designed, metal exhaust ventilator designed to evacuate hot and/or moisture - laden air from attics. 2. Each vent provides 51 sq in (32900 sq mm) NFVA. 3. Aluminum and galvanized steel available in Weathered Grey, Brown, Black, or Mill Finish. 4. 16 in (406 mm) by 20 in (508 mm) base, 8 in (203 mm) diameter opening. 5. Suitable on roofs with a pitch up to 12:12. 6. Standards/Qualifications: TDI listed for usage in Texas Coastal Region (RV -20) E. Plastic Slant Back Roof Vent 1. Rooftop mounted, slant -back design with full screen, high -impact resin exhaust ventilator designed to evacuate hot and/or moisture -laden air from attics. 2. Each vent provides 55 sq in (35500 sq mm) NFVA. 3. Available in Weathered Grey, Brown, Black, Cedar, or White finish. 4. 17 in (432 mm) by 18 in (457 mm) base, 9 in (229 mm) by 9 in (229 mm) opening. 5. Standards/Qualifications: TDI listed for usage in Texas Coastal Region (RV -20). F. VentSure® Metal Square Top Roof Vent 1. Rooftop mounted, square -top designed, metal exhaust ventilator designed to evacuate hot and/or moisture - laden air from attics. 2. Each vent provides 51 sq in (32900 sq m) NFVA. 3. Aluminum and galvanized steel available in Weathered Grey, Brown, Black, or Mill finish. 4. 16-1/2 in (419 mm) by 17-1/2 in (445 mm) base, 8 in (203 mm) by 8 in (203 mm) opening. 5. Suitable on roofs with a pitch up to 12:12. G. VentSure® Low Profile Slant Back Roof Vent with Exterior Louver 1. Rooftop mounted, low -profile, slant back metal exhaust ventilator designed to evacuate hot and/or moisture - laden air from attics. 2. Each vent provides 72 sq in (46500 sq mm) NFVA. 3. Galvanized steel available in Black, White Brown, Light Grey, Dark Gray, or Mill finish. 4. 32 in (813 mm) by 23 in (584 mm) base, 11 in (279 mm) by 11 in (279 mm) opening. Available with extended flange 36 in (914 mm) by 28 in (711 mm). 5. Suitable on roofs with a 3:12 pitch or greater. 6. Standards/Qualifications: Miami -Dade County Product Approval (11-0512.02). H. VentSure® Metal Dome with Screen 1. Rooftop mounted, dome, metal exhaust ventilator designed to evacuate hot and/or moisture -laden air from attics, while prohibiting snow infiltration. OWENS CORNING INNOVATIONS FOR LIVING' Fiberglass -Based Asphalt Shingles & Accessories Guide Specifications 2. Each vent provides 144 sq in (92900 sq mm) NFVA. 3. Galvanized steel available in Weathered Grey, Brown, Black, or Mill finish. 4. 25 in (635 mm) by 25 in (635 mm) base, 15 in (381 mm) diameter opening. 5. Suitable on roofs with a pitch up to 8:12. VentSure® Internally Braced Premium Turbine Vent 1. Rooftop mounted, turbine designed, metal exhaust ventilator designed to evacuate hot and/or moisture - laden air from attics with sealed and lubricated stainless steel ball bearings. 2. Aluminum and galvanized steel available in Weathered Grey, Brown, Black, or Mill finish. 3. Available with 12 in (305 mm) diameter opening and 16 in (406 mm) base or 14 in (356 mm) diameter opening with 18 in (457 mm) base. J. VentSure® Internally Braced Standard Turbine Vent 1. Rooftop mounted, turbine designed, metal exhaust ventilator designed to evacuate hot and/or moisture - laden air from attics. 2. Aluminum and galvanized steel available with a 12 in (305 mm) or 14 in (356 mm) opening. 3. 12 in (305 mm) opening with 16 in (406 mm) base available in Brown, Black, or Mill finish. 4. 14 in (356 mm) opening with 16 in (406 mm) base available in Mill finish. K. VentSure® Externally Braced Premium Turbine Vent 1. Rooftop mounted, turbine designed, metal exhaust ventilator designed to evacuate hot and/or moisture - laden air from attics with sealed and lubricated stainless steel ball bearings. 2. Aluminum and galvanized steel available in Weathered Grey, Brown, Black, or Mill finish. 3. Available with 12 in (305 mm) opening and 16 in (406 mm) base. L. VentSure® 1400 CFM Powered Roof Vent 1. Rooftop mounted, 1400 CFM (39.6 cu m/min), metal exhaust ventilator designed to evacuate hot and/or moisture -laden air from attics. 2. Each vent provides ventilation for 2000 sq ft (186 sq m) attic 3. Includes adjustable thermostat and humidistat and 4.5 Amp motor. 4. Aluminum and galvanized steel available in Weathered Grey, Brown, Black, or Mill finish. 5. 25 in (635 mm) by 25 in (635 mm) base with 15 in (381 mm) opening. 6. Suitable on roofs with a pitch up to 8:12. M. VentSure® 1080 CFM Powered Roof Vent 1. Rooftop mounted, 1080 CFM (30.6 cu m/min), metal exhaust ventilator designed to evacuate hot air from attics. 2. Each vent provides ventilation for 1600 sq ft (149 sq m) attic. 3. Includes adjustable thermostat and humidistat and 2.6 Amp motor. 4. Aluminum and galvanized steel available in Weathered Grey, Brown, Black or Mill finish. 5. 25 in (635 mm) by 25 in (635 mm) base with 15 in (381 mm) opening. 6. Suitable on roofs with a pitch up to 8:12. N. VentSure® Aluminum Undereave Intake Vent 1. Rectangular aluminum intake vents designed to introduce fresh, dry air into the attic. Pre -drilled holes for easy installation and fully screened for first line of defense against insects. 2. Available in Mill and White and three different dimensions designed to work collectively with exhaust vents to provide ventilation to roof structures. 3. 4 in (102 mm) by 16 in (406 mm) opening provides 16.34 sq in (10500 sq mm) NFVA, 6 in (152 mm) by 16 in (406 mm) opening provides 27.23 sq in (17600 sq mm) NFVA and 8 in (203 mm) by 16 in (406 mm) opening provides 38.12 sq in (24600 sq mm) NFVA. 0. VentSure® 8 ft (2.4 m) Continuous Soffit Vent 1. 8 ft (2.4 m) continuous aluminum soffit vent offering 37.47 sq in (24200 sq mm) NVFA. 2. Available in 2 in (51 mm) widths, designed to work collectively with exhaust vents to provide ventilation to roof structures. P. VentSure® Round Mini Soffit Vent 1. Round miniature aluminum soffit vents designed to introduce fresh, dry air into the attic. 2. Available in Mill finish and three sizes designed to work collectively with exhaust vents to provide ventilation to roof structures. 3. 2 in (51 mm) round opening provides 0.64 sq in (4100 sq mm) NFVA, 3 in (76 mm) round opening provides 1.36 sq in (8800 sq mm) NFVA, and 4 in (102 mm) round opening 2.43 sq in (15700 sq mm) NFVA. C)WENS CORNING INNOVATIONS FOR LIVING' Fiberglass -Based Asphalt Shingles & Accessories Guide Specifications Q. VentSure® InFlown' Vent 1. Shingle -over, polypropylene intake vent solution for soffit -less and open -rafter homes, and homes with inadequate intake. Designed to work with exhaust ventilation to help achieve a balanced air ventilation system. 2. Patent -pending bottom intake design helps protect against wind -driven rain. 3. 4 ft (2.4 m) strip provides 10 sq in (6500 sq mm) NFVA per lineal foot, or 40 sq in (25800 sq mm) NFVA per vent 4. Weather PROtector® Moisture Barrier provides added protection against wind -driven rain and snow infiltration. 5. Roof Mount Unit dimensions: 48 in (1219 mm) length, 15 in (381 mm) width and 1 in (25 mm) height. 6. Suitable for use on roofs with a pitch from 4:12 to 16:12. 7. Standards/Qualifications: ICC -ES AC132; TDI listed for usage in Texas Coastal Region (Pending) and Florida Product Approval (Pending). R. VentSure® Solar Attic Exhaust Fan: Roof Mount Unit 1. 25 -Watt solar -powered attic ventilator efficiently exhausts hot, humid air from the attic. Designed to work as part of a balanced air ventilation system in conjunction with Undereave/Soffit vents. 2. Electronic thermostat and humidistat for efficient operation. 3. Electric backup available for hookup for continued operation after dusk or when adequate solar power is not available. 4. Ventilates up to 3200 sq ft (297 sq m) attic space (under certain conditions, including adequate intake ventilation). 5. 38 -volt DC Motor (variable speed) with external brushes. 6. 14 in (356 mm) 3 -wing ultra quiet aluminum blades with pitch angle matched to motor/solar panel. 7. Black, powder -coated, 20 gauge, 0.0396 in (1.006 mm) galvanized steel flashing and housing. 8. Remote Attic Monitor (optional) displays attic temp, humidity, fan operation, and source of power via portable device from almost anywhere in the home. 9. Roof Mount Unit dimensions: 26 in (660 mm) length, 26 in (660 mm) width, 10-3/16 in (259 mm) height; Solar Panel Dimensions: 18-3/4 in (476 mm) length, 17-1/4 in (438 mm) width and 1 in (25 m) height; 36.0 lbs (16.3 kg) shipping weight. 10. Suitable for use on asphalt -shingled roof decks with a pitch from 3:12 to 16:12. 11. Standards/Qualifications: TDI listed for use in Texas Coastal Regions (Pending); Florida Product Approval (FL16166), and complies with UL 1703 impact resistance requirements. S. VentSure® Solar Attic Exhaust Fan: Gable Mount Unit 1. 25 -Watt solar -powered attic ventilator efficiently exhausts hot, humid air from the attic. Designed to work as part of a balanced air ventilation system in conjunction with Undereave/Soffit vents. 2. Only the solar panel is mounted on the roof with the Gable Mount Solar Attic. The fan is mounted in the attic and vents out the gable vents. 3. Electronic thermostat and humidistat for efficient operation. 4. Electric backup available for hookup for continued operation after dusk or when adequate solar power is not available. 5. Ventilates up to 4200 sq ft (390 sq m) attic space (under certain conditions, including adequate intake ventilation) 6. 38 -volt DC Motor (variable speed) with external brushes. 7. 14 in (356 mm) 3 -wing ultra quiet aluminum blades with pitch angle matched to motor/solar panel 8. Fan housing is electro -deposition, galvanized, powder coated with 3 mils to 5 mils (0.076 mm to 0.127 mm) thickness. 9. Remote Attic Monitor (optional) displays attic temp, humidity, fan operation, and source of power via portable device from almost anywhere in the home. 10. Gable -Mount Solar Fan Dimensions: 16 in (406 mm) length, 14 in (356 mm) width, and 8-1/2 in (216 mm) height; Solar Panel Dimensions: 18-3/4 in (476 mm) length, 17-1/4 in (438 mm) width and 1 in (25 mm) height; 25.7 lbs (11.6 kg) shipping weight. 11. Suitable for use on roofs with a pitch from 3:12 to 16:12. 12. Standards/Qualifications: Solar panel complies with UL 1703 impact resistance requirements. 2.8 SKYLIGHTS **NOTE TO SPECIFIER** Delete skylight products from the list below that are not required. **NOTE TO SPECIFIER** Verify with the manufacturer regional product availability. A. Illuminator® Tube Skylight - Non -impact Resistant Unit OWENS CORNING INNOVATIONS FOR LIMING° Fiberglass -Based Asphalt Shingles & Accessories Guide Specifications 1. Innovative solution for bringing natural light into home, reducing reliance on electricity. Units with composite and aluminum flashing are recommended for use with asphalt -shingled roofs, wood shakes, and slate roof types. Units with formable flashing are recommended for use with tile and metal roof applications. 2. Available in two sizes 10 in (254 mm) or 14 in (356 mm) acrylic dome, reflecting the equivalent of up to 300 - Watts with a 10 in (254 mm) unit or 500 -Watts with a 14 in (356 mm) unit of natural light. 3. Light is distributed evenly over 150 sq ft (13.9 sq m) area with a 10 in (254 mm) unit or 300 sq ft (27.9 sq m) area with a 14 in (356 mm) unit via adjustable, reflective tubing. 4. Black, composite flashing is designed to prevent leaking and is pitched for easier installation. 5. Units sold as a complete kit containing 4 ft (1.2 m) of adjustable, reflective tubing, a weather -resistant dome, one-piece flashing, and Energy Star rated diffuser lens. 6. Optional Electric Light Kit available for 10 in (254 mm) and 14 in (356 mm) units. 7. Remote control operated Solar Powered Dimmer allows full control over amount of light entering a room, without using electricity. For 10 in (254 mm) units only. 8. Standards/Qualifications: ASTM D635, ASTM D1929, ASTM D2843, ICC -ESR 1835, AAMA/WDMA/CSA 101/1.2S/A440, ENERGY STAR qualified, Florida Product Approval (FL15095.1), and TDI listed for usage in Texas Coastal Region (SK -35). B. Illuminator® Tube Skylight - Impact Resistant Unit for use outside (High Velocity Hurricane Zone) HVHZ. 1. Innovative solution for bringing natural light into home, reducing reliance on electricity. Recommended for tile and metal roof applications. 2. Available in two sizes 10 in (254 mm) or 14 in (356 mm) polycarbonate dome, reflecting the equivalent of up to 300 -Watts with a 10 in (254 mm) unit or 500 -Watts with a 14 in (356 mm) unit of natural light. 3. Light is distributed evenly over 150 sq ft (13.9 sq m) area with a 10 in (254 mm) unit or 300 sq ft (27.9 sq m) area with a 14 in (356 mm) unit via adjustable, reflective tubing. 4. Silver, one-piece formable aluminum flashing is designed to prevent leaking. Secondary, formable flashing also included. 5. Units sold as a complete kit containing 4 ft (1.2 m) of adjustable, reflective tubing, a weather -resistant dome, one-piece flashing plus secondary flashing, and Energy Star rated diffuser lens. 6. Optional Electric Light Kit available for 10 in (254 mm) and 14 in (356 mm) units. 7. Remote control operated Solar Powered Dimmer allows full control over amount of light entering a room, without using electricity. For 10 in (254 mm) units only. 8. Standards/Qualifications: ASTM D635, ASTM D1929, ASTM D2843, ICC -ESR 1835, AAMANVDMA/CSA 101/1.2S/A440, ENERGY STAR qualified, Florida Product Approval (FL15095.2), and TDI listed for usage in Texas Coastal Region (SK -36). C. Illuminator® Tube Skylight - Impact Resistant Unit for use within and outside HVHZ. 1. Innovative solution for bringing natural light into home, reducing reliance on electricity. 2. Available in two sizes 10 in (254 mm) or 14 in (356 mm) polycarbonate dome, reflecting the equivalent of up to 300 -Watts with a 10 in (254 mm) unit or 500 Watts with a 14 in (356 mm) unit of natural light. 3. Light is distributed evenly over 150 sq ft (13.9 sq m) area with a 10 in (254 mm) unit or 300 sq ft (27.9 sq m) area with a 14 in (356 mm) unit via adjustable, reflective tubing. 4. Black, spun aluminum flashing is designed to prevent leaking. 5. Units sold as a complete kit containing 4 ft (1.2 m) of adjustable, reflective tubing, a weather -resistant dome, one-piece flashing, and Energy Star rated diffuser lens. 6. Optional Electric Light Kit available for 10 in (254 mm) and 14 in (356 mm) units. 7. Remote control operated Solar Powered Dimmer allows full control over amount of light entering a room, without using electricity. For 10 in (254 mm) units only. 8. Standards/Qualifications: ASTM D635, ASTM D638, ASTM D1929, ASTM D2843, ICC -ESR 1835, AAMANVDMA/CSA 101/1.2S/A440, ENERGY STAR qualified, Florida Product Approval (FL15095.3), and TDI listed for usage in Texas Coastal Region (SK -36). 2.9 FASTENERS A. Fasteners: Galvanized steel, stainless steel, or aluminum nails complying with ASTM F1667, minimum 12 gauge, 0.0808 in (2.05 mm) shank with 3/8 in (9.5 mm) diameter head. B. All fasteners must be driven flush with the shingle surface and penetrate at least 3/4 in (19.1 mm) into the wood deck. Where the deck is less than 3/4 in (19.1 mm) thick, the fastener should be long enough to penetrate fully and extend through roof sheathing. 2.10 METAL FLASHING A. Flashing: Provide flashing as specified by Section 07600 - Metal Flashing and Sheet Metal. Fiberglass -Based Asphalt Shingles & Accessories OWENS CORNING INNOVATIONS FOR LIVING' Guide Specifications PART 3 EXECUTION 3.1 EXAMINATION A. Prior to starting work, examine all roof decks on which work is to be applied for defects in materials and workmanship which may be detrimental to the proper installation or long-term performance of the shingles. B. Underlayment and shingles installed directly over roof insulation or similar type decks is not approved. 1. Roof deck must be dry, minimum 25/32 in (19.8 mm) thick, minimum 6 in (152 mm) wide boards with maximum 1/4 in (6.4 mm) spaces, or APA rated sheathing (exposure 1): minimum 3/8 in (9.5 mm) plywood, minimum 7/16 in (11.1 mm) oriented strand board. Consult your manufacturer for other approved constructions. 2. Ventilation under the roof deck must meet local code requirements. C. Do not begin installation until the roof deck has been properly prepared. D. If substrate preparation is the responsibility of another installer, notify Architect of unsatisfactory preparation before proceeding. Commencement of installation constitutes acceptance of conditions. 3.2 PREPARATION A. Prepare surfaces using the methods recommended by the manufacturer for achieving the best result for the substrate under the project conditions. B. Remove all existing roofing down to the roof deck. C. Verify installed roof deck is acceptable to receive shingles. Acceptable roof decks include the following: 1. Lumber sheathing: 6 in (152 mm) minimum width, 25/32 in (19.8 mm) minimum thickness. 2. Plywood sheathing: 3/8 in (9.5 mm) minimum thickness Exposure 1 grade plywood sheathing as recommended by APA and in compliance with applicable Codes. 3. OSB panels: 7/16 in (11.1 mm) minimum thickness non -veneer structural panels as recommended by APA and in compliance with applicable Codes. 4. Spacing between boards or panels shall not exceed 1/4 in (6.4 mm) between roof boards or between plywood or OSB sheathing panels. D. Verify that the deck is dry, structurally sound, clean and smooth. It shall be free of any depressions, waves, and projections. Cover with minimum 28 gauge; 0.0187 in (0.475 mm) galvanized steel, 0.0156 in (0.396 mm) stainless steel, or 0.0126 in (0.320 mm) aluminum sheet metal all holes 1 in (25 mm) or less in diameter, cracks over 1/2 in (13 mm) in width, loose knots and excessively resinous areas. Decking or deck boards with holes greater than 1 in (25 mm) in diameter shall be replaced. E. Verify that the deck is structurally sound and free of deteriorated decking. All deteriorated and damaged decking shall be removed and replaced with new materials. F. Clean deck surfaces thoroughly prior to installation of self-sealing ice and water barrier and underlayment. G. Verify that the existing shingles are dry, sound, clean and smooth. All curled, buckled or loose tabs shall be nailed down or removed. 3.3 UNDERLAYMENT APPLICATION A. Install in accordance with manufacturer's instructions. 1. Install using methods recommended by shingle manufacturer and in accordance with local building codes. When local codes and application instructions are in conflict, the local code requirements shall take precedence. 2. Install self -adhering ice and water barrier from the eaves edge of roof up the slope a full 36 in (914 mm) but not less than 24 in (610 mm) beyond the interior edge of the exterior wall. Lap ends 6 in (152 mm) on roof decks sloped 5:12 and greater. On roofs with pitch from 2:12 up to 4:12, see application instructions printed on each package. B. Drip Edge 1. Drip edge shall be installed on all roof edges. rgf2larT, INNOVATIONS FOR LIVING` Fiberglass -Based Asphalt Shingles & Accessories Guide Specifications 2. Install drip edge on eaves first with underlayment installed over the drip edge. 3. Install drip edge on rakes after underlayment is installed, with the drip edge fastened over the underlayment. 4. Joints in drip edge shall be lapped minimum 2 in (51 mm) with the upslope piece lapped over the down slope piece. 5. Install fastener 8 in to 10 in (203 mm to 254 m) on center, approximately 1-3/4 in (44 mm) from the outside edge of the drip edge. C. Valleys 1. Install self -adhering ice and water barrier at least 36 in (914 mm) wide and centered on the valley. Lap ends 6 in (152 mm) and seal. 2. Where valleys are indicated to be "open valleys", install metal flashing over self -adhering ice and water barrier before roof deck underlayment is installed; DO NOT nail through the flashing. Secure the flashing by nailing at 18 in (457 mm) on center just beyond edge of flashing so that nail heads hold down the edge, or use valley metal with a formed edge and secure with clips. D. Roof Deck 1. On roofs with pitch greater than 4:12, lap horizontal edges at least 2 inches (51 mm) and at least 2 inches (51 mm) over self -adhering ice and water barrier. Lap ends at least 4 inches (102 m). End laps in succeeding course should be located at least 6 ft (1.8 m) from end laps in the preceding course. 2. On roofs with pitch between 2:12 to less than 4:12, see application instructions printed on each shingle wrapper, or follow local code requirements. 3. Lap underlayment over valley protection at least 6 inches (152 mm). E. Penetrations 1. Vent pipes: Install a 24 in (610 mm) square piece of self -adhering ice and water barrier lapping over roof deck underlayment; seal tightly to pipe. 2. Vertical walls: Install self -adhering ice and water barrier extending at least 3 in to 4 in (76 mm to 102 mm) up the wall and 12 in (305 mm) on to the roof surface. Lap the membrane over the roof deck underlayment. 3. Chimneys: Install self -adhering ice and water barrier around entire chimney extending at least 6 in (152 mm) up the wall and 12 in (305 mm) on to the roof surface. Lap the membrane over the roof deck underlayment. 3.4 SHINGLE INSTALLATION A. Install shingles in accordance with manufacturer's printed installation instructions. B. Install starter course at lowest roof edge and along rake with edge of shingles extending 1/4 in (6.4 mm) over edge of roof. C. Install first and successive courses of shingles stepping diagonally up and across roof deck with manufacturer's recommended offset at each succeeding course. Maintain uniform exposure of shingles at each succeeding course. D. Fasten shingles to deck with manufacturer's recommended number of roofing nails per shingle, or in accordance with local codes. E. Install ridge vents and shingles at valleys, hips and ridges in accordance with manufacturer's recommendations and local code requirements. 3.5 PROTECTION A. Protect installed products until completion of project. B. Touch-up, repair or replace damaged products before Substantial Completion. END OF SECTION All Rights Reserved. The color PINK is a registered trademark of Owens Coming Roofing and Asphalt, LLC. ©2013 Owens Coming Roofing and Asphalt, LLC. All Rights Reserved. FILE UL Evaluation Report UL ER2453-01 Issued: August 2, 2013 Revised: January 30, 2015 Visit UL's On -Line Certifications Directory: WWW.ul.com/erdirectory for current status of Report. UL Category Code: ULEZ CSI MasterFormat® DIVISION: 07 00 00 — Sub -level 2: 07 30 00 — Sub -level 3: 07 31 00 Sub -level 4: 07 31 13 COMPANY: THERMAL AND MOISTURE PROTECTION Steep Slope Roofing — Shingles and Shakes — Asphalt Shingles OWENS CORNING ONE OWENS CORNING PKY TOLEDO, OH 43659 (419) 248-7060 http://www.owenscorning.com/ 1. SUBJECT: Asphalt Shingles CLASSIC®, SUPREME® RECEIVED CITY OF TUKWILA OCT 112016 PERMIT CENTER DURATION® PREMIUM, TRUDEFINITION® DURATION®, TRUDEFINITION® DURATION® STORM TM, TRUDEFINITION® DURATION® MAXTM, TRUDEFINITION® OAKRIDGE®, OAKRIDGE®, WOODCREST®, WOODMOOR®, TRUDEFINITION® WEATHERGUARD® HP, BERKSHIRE®, DEVONSHIRE"' WOODSTART® STARTER SHINGLE, STARTER STRIP PLUS, STARTER STRIP SHINGLE, AND TRI BUILT STARTER STRIP BERKSHIRE® HIP & RIDGE SHINGLES, HIGH RIDGE HIP & RIDGE SHINGLES WITH SEALANT, RIZERIDGE® HIP & RIDGE SHINGLES WITH SEALANT, WEATHERGUARD® HP HIP & RIDGE SHINGLES, PROEDGE®, DURARIDGETM HIP & RIDGE SHINGLES AND PROEDG -SIORM.Q.HJP & RIDGE SHINGLES REVIEWED FOR CODE COMPLIANCE 2. SCOPE OF EVALUATION ■ 2012, 2009, and 2006 International Building Code ® (IBC) ■ 2012, 2009, and 2006 International Residential Code ® (IRC) • ICC ES Acceptance Criteria for Quality Documentation (AC10), Dated December 012 City of Tukwila • ICC ES Acceptance Criteria for Alternative Asphalt Roofing Shingles (AC438), Da APPROVED OCT 14 2016 IL ;I� DIVISION Dltp--01s0 The products were evaluated for the following properties: • External Fire Exposure (ANSI/UL790, ASTM E108) • Wind Resistance (ASTM D3161; ASTM D7158) • Physical Properties (ASTM D3462, ICC -ES AC438) 3. REFERENCED DOCUMENTS • ANSI/UL790 (ASTM E108), Standard Test Methods for Fire Tests of Roof Coverings • ASTM D3161, Standard Test Method for Wind -Resistance of Steep Slope Roofing Products (Fan - Induced Method) • ASTM D7158, Standard Test Method for Wind Resistance of Asphalt Shingles (Uplift Force/Uplift Resistance Method) • ASTM D3462, Standard Specification for Asphalt Shingles Made from Glass Felt and Surfaced with Mineral Granules • UL Subject 2375, Outline of Investigation for Hip and Ridge Shingles (UL Fire and Wind Tests) • ICC -ES Acceptance Criteria for Alternative Asphalt Roofing Shingles (AC438), Dated March 2012 4. USES OWENS CORNING asphalt shingles are used as roof coverings for new and existing roofs. 5. PRODUCT DESCRIPTION OWENS CORNING asphalt shingles are roof covering materials complying with the following properties when installed as described in this report and as shown in illustrations for application instructions which accompany each bundle of shingles. The products are three -tab shingles, laminated shingles and hip & ridge shingles. The products are available in standard and metric sizes. Fire Classification: OWENS CORNING asphalt shingles covered under this Report have been tested for fire classification Class A in accordance with UL790 (ASTM E108). Shingles tested in accordance with UL790 (ASTM E108) qualify for use under Section 1505.1 of the 2012, 2009 and 2006 IBC and Section R902.1 of the 2012, 2009 and 2006 IRC. Wind Resistance: OWENS CORNING asphalt shingles covered under this Report have been tested for wind resistance in accordance with ASTM D3161 or ASTM D7158. Shingles tested in accordance with ASTM D3161 are classified as Class F or Class A and qualify for use under the exception to Section 1507.2.7.1 of the 2012, 2009 and 2006 IBC, or the exception to Section R905.2.4.1 of the 2012, 2009 and 2006 IRC. Shingles tested in accordance with ASTM D7158 are classified as Class H and qualify for use in locations as shown in Table 1507.2.7.1 of the 2012 and 2009 IBC or Table R905.2.4.1 of the 2012 and 2009 IRC, where the maximum basic wind speed is 150 mph (67 m/s) or less with exposure category of B or C (ASCE 7) and a maximum building height of 60 feet (18.3 m). Installation must be in accordance with Section 1507.2.7 of the 2012, 2009 and 2006 IBC or Section R905.2.6 of the 2012, 2009 and 2006 IRC, as applicable. Physical Properties: OWENS CORNING asphalt shingles covered under this Report have been tested for physical properties in accordance with ASTM D3462. Shingles tested in accordance with ASTM D3462 qualify for use under Section 1507.2.5 of the 2012, 2009 and 2006 IBC or Section R905.2.4 of the 2012, 2009 and 2006 IRC. Shingles have also been evaluated in accordance with ICC -ES Acceptance Criteria, AC438. When installed on new construction in accordance with this report and the OWENS CORNING installation instructions, the shingles are a Class A fire classification roof covering. When the shingles are installed over existing roof coverings, the fire classification is maintained. Page 2 of 11 5.1 Three -Tab Shingles — Classic®, and Supreme®: Classic® and Supreme® shingles are three -tab shingles manufactured with a single fiberglass mat, coated on both sides with asphalt, and surfaced on the weather -exposed side with mineral granules. The shingles are self-sealing and have a continuous bead of thermal -tab sealing adhesive above the shingle butt on the weather side. The shingles are self-sealing and have a dashed bead of thermal -tab sealing adhesive above the shingle butt on the weather side. 5.2 Five -Tab Shingles - Devonshire TM DevonshireTM shingles are five -tab shingles manufactured with a single fiberglass mat, coated on both sides with asphalt, and surfaced on the weather -exposed side with mineral granules. The shingles are self-sealing and have a dashed bead of thermal -tab sealing adhesive above the shingle butt on the weather side. 5.3 Laminated Shingles — Duration® Premium, TruDefinition® Duration®, TruDefinition® Duration® Storm, TruDefinition® Duration® MAX, TruDefinition® Oakridge®, Oakridge®, Woodcrest®, Woodmoor®, TruDefinition® WeatherGuard® HP, Berkshire®: Duration® Premium, TruDefinition® Duration®, TruDefinition® Duration® Storm, TruDefinition® Duration® MAX, Oakridge®, Woodcrest®, Woodmoor®, TruDefinition® WeatherGuard® HP, Berkshire® shingles are laminated shingles manufactured with 2 layers of fiberglass mat coated with asphalt on both sides, and surfaced on the weather -exposed side with mineral granules. 5.4 Hip & Ridge Shingles — Berkshire® Hip & Ridge Shingles, High Ridge Hip & Ridge with Sealant, ProEdge®, ProEdge® Storm®, WeatherGuard® HP, DuraRidgeTM Hip and Ridge Shingles, and RIZERidge® Hip and Ridge shingles with Sealant: Berkshire® Hip & Ridge Shingles, High Ridge Hip and Ridge Shingles with Sealant, ProEdge®, ProEdge StormTM, WeatherGuard® HP, DuraRidgeTM Hip and Ridge Shingles and RIZERidge® Hip and Ridge shingles with Sealant are prefabricated hip and ridge shingles. ProEdge Storm TM and WeatherGuard® HP hip and ridge shingles are perforated so they can be torn into three 12 inch by 12 inch (305 mm by 305 mm) shingles. ProEdge® hip and ridge shingles and RIZERidge® Hip and Ridge shingles with Sealant are perforated so they can be torn into three 12 inch by 12 inch (305 mm by 305 mm) shingles for standard , or four 13-% inch by 9-27/32 inch (337 mm by 250 mm) shingles for metric. 5.5 Starter Shingles - Starter Strip, Starter Strip Plus, Woodstart Starter Shingle, and Tri -Built Starter Strip Starter Strip, Starter Strip Plus, Woodstart Starter Shingle, and Tri -Built Starter Strip are prefabricated starter course shingles with factory applied sealant. Starter Strip and Tri -Built Starter Strip are 6-5/8" x 39-3/8". Starter Strip Plus and Tri -Built Starter Strip are 7-3/4" x 13-3/8". Woodstart Starter Shingles are 13-3/8" x 40". 6. INSTALLATION OWENS CORNING asphalt shingles must be installed in accordance with the applicable code, this report, and the manufacturer's published installation instructions. The shingles must be installed in accordance with Section 1507.2 of the 2012, 2009 and 2006 IBC or Section R905.2 of the 2012, 2009 and 2006 IRC, as applicable, except as noted in this report. Page 3of11 The manufacturer's published installation instructions must be available at all times on the jobsite during installation. Minimum roof slopes must be 2:12 (16.67% slope or 9°) for the three -tab shingles described in section 5.1 and for the laminated shingles described in section 5.3 of this Report. 6.1 Underlayment and Ice Barriers: For roof slopes greater than 4:12 (33.33% slope or 18°), the roof deck must be covered with a minimum of one layer of underlayment as described in Sections 7.2 and 7.3 of this Report. Underlayment application must be in accordance with Section 1507.2.8 of the 2012, 2009 and 2006 IBC or Section R905.2.7 of the 2012, 2009 and 2006 IRC, as applicable. Roofs having slopes between 2:12 (16.67% slope or 9°) and 4:12 (33.33% slope or 18°) require two layers of the underlayment as described in Sections 7.2 and 7.3 of this Report. Underlayment application must be in accordance with Section 1507.2.8 of the 2012, 2009 and 2006 IBC or Section R905.2.7 of the 2012, 2009 and 2006 of the IRC, as applicable. In areas where there has been a history of ice forming along the eaves, causing a backup of water, as indicated by Table R301.2 (1), an ice barrier must be provided in accordance with Section 1507.2.8.2 of the 2012, 2009 and 2006 IBC or Section R905.2.7.1 of the 2012, 2009 and 2006 IRC, as applicable. 6.2 Starter Shingle: A starter course, as described in Section 7.4 of this Report, must be attached to the eave edge using fasteners described in Section 7.5 of this Report, located 1-1/2 — 3 inches (38 — 76 mm) from the eave edge and spaced 8 —10 inch (203 — 254 mm) apart, for a total of five fasteners per shingle. The starter strip must overhang the eaves and rake edges by'/ —3A inch (6 — 19 mm). 6.3 Asphalt Shingles: The first course of field shingles must be installed over the starter course described in Section 7.4 of this Report. Standard three -tab shingles must be installed with vertical joints offset 4 inches (102 mm), 5 inches (127 mm), or 6 inches (152 mm) from adjacent courses and metric -sized three -tab shingles must be installed with a 6-9/16 inch (167 mm) offset or any repeatable offset pattern greater than 4 inches (102 mm). Duration® Premium, TruDefinition® Duration®, TruDefinition® Duration® Storm TM TruDefinition® Duration® MAX, TruDefinition® Oakridge®, Oakridge®, and TruDefinition® WeatherGuard® HP must be installed with a 6-1/2 inch (165 mm) offset or any repeatable offset pattern greater than 4 inches (102 mm). The Berkshire® shingles must be installed with a 4-3/4 inch (121 mm) offset. Woodcrest® and Woodmoor® must be installed with a 5 and 5 inch (127 and 127 mm) or a 5 inch and 15 inch (127 and 381 mm) offset. End joints must be a minimum of 2 inches (51 mm) from a fastener in the shingle below. Offset patterns between courses may vary provided side laps are a minimum of 4 inches (102 mm) in succeeding courses. Page 4 of 11 6.3.1 Three -Tab Shingles — Classic®, and Supreme®: For roof slopes of 2:12 up to 21:12 (16.67% or 9° up to 175% or 60°), each shingle must be fastened to the roof deck using a minimum of four fasteners. For roof slopes over 21:12 (175% or 60°), six fasteners must be used and four 1 inch diameter spots of asphalt plastic cement per shingle (2 inches up from the bottom edge). Fasteners must be located above the top of the cut-out and below the sealant strip, 5/8 inch (16 mm) above the tab cut-out. Maximum exposure to the weather must be 5 inches or 55/8 ± 1/8 inches (127 or 143 ± 3 mm). In colder climates or wind regions where it is questionable whether the thermal -sealing adhesive will activate to seal the shingles, the shingles can be hand -sealed. A 1 -in diameter (25.4 mm) spot of asphalt cement complying with ASTM D4586, Type I, Class I, should be placed under the corner (1 — 2 inches (25 — 51 mm) from each end) of each tab (two spots per tab). 6.3.2 Five -Tab Shingles — DevonshireTM: For roof slopes of 2:12 up to 21:12 (16.67% or 9° up to 175% or 60°) each shingle must be fastened to the roof deck using a minimum of six fasteners. For roof slopes over 21:12 (175% or 60°), six fasteners must be used, and ten 1 inch diameter spots of asphalt plastic cement per shingle and two spots of asphalt plastic cement under each shingle tab. Fasteners must be located 6-1/8 inches (157 mm) above the butt edge of the shingles. Maximum exposure to the weather must be 55/8 ±'/8 inches (143 ± 3 mm). In colder climates or wind regions where it is questionable whether the thermal -sealing adhesive will activate to seal the shingles, the shingles can be hand -sealed. Two, 1 -inch diameter (25.4 mm) spots of cement should be placed under each shingle (Ten per shingle). 6.3.3 Laminated Shingles — Duration® Premium, TruDefinition® Duration®, TruDefinition® Duration® Storm, TruDefinition® Duration® MAX: For roof slopes of 2:12 up to 21:12 (16.67% or 9° up to 175% or 60°), each shingle must be fastened to the roof deck using a minimum of four fasteners. For roof slopes over 21:12 (175% or 60°), six fasteners must be used. Fasteners must be located 6-1/8 inches (157 mm) above the butt edge of the shingles (center of the SureNail® fastening area). Maximum exposure to the weather must be 55/8 ±'/8 inch (143 ± 3 mm) In colder climates or wind regions where it is questionable whether the thermal -sealing adhesive will activate to seal the shingles, the shingles can be hand -sealed. Four, 1 -inch diameter (25.4 mm) spots of cement should be placed under the exposed portion of the shingle, spaced 1 — 2 inches (25 — 51 mm) from each end of the shingle and two spots must be evenly spaced in between. Page 5of11 6.3.4 Laminated Shingles — Oakridge® and TruDefinition® Oakridge®: For roof slopes of 2:12 up to 21:12 (16.67% or 9° up to 175% or 60°), each shingle must be fastened to the roof deck using a minimum of four fasteners. For roof slopes over 21:12 (175% or 60°), six fasteners must be used, and four 1 inch diameter spots of asphalt plastic cement per shingle (2 inches up from the bottom edge). Fasteners must be located 6-1/8 inches (157 mm) above the butt edge of the shingles. Maximum exposure to the weather must be 5-5/8± 1/8 inches (143 ± 3 mm) In colder climates or wind regions where it is questionable whether the thermal -sealing adhesive will activate to seal the shingles, the shingles can be hand -sealed. Four, 1 -inch diameter (25.4 mm) spots of cement should be placed under the exposed portion of the shingle, spaced 1 — 2 inches (25 — 51 mm) from each end of the shingle and two spots must be evenly spaced in between. 6.3.5 Laminated Shingles — Berkshire®: For roof slopes of 2:12 up to 21:12 (16.67% or 9° up to 175% or 60°), each shingle must be fastened to the roof deck using a minimum of five fasteners. For roof slopes over 21:12 (175% or 60°), six fasteners must be used and four 1 inch diameter spots of asphalt plastic cement per shingle and one spot of asphalt under each shingle tab, center of the shingle tab and 2 inches up from the bottom edge. Fasteners must be located above the top of the cut-out and below the sealant strip, 5/8 inch (16 mm) above the tab cut-out. Maximum exposure to the weather must be 82/8 ±'/8 inch (213 ± 3 mm). In colder climates or wind regions where it is questionable whether the thermal -sealing adhesive will activate to seal the shingles, the shingles can be hand -sealed. A 1 -inch diameter (25.4 mm) spot of asphalt cement complying with ASTM D4586, Type I, Class I, should be placed under the corner 1 — 2 inches (25 — 51 mm) from each end of each tab (two spots per tab). 6.3.6 Laminated Shingles — Woodcrest® and Woodmoor®: For roof slopes of 2:12 up to 21:12 (16.67% or 9° up to 175% or 60°), each shingle must be fastened to the roof deck using a minimum of five fasteners. For roof slopes over 21:12 (175% or 60°), nine fasteners must be used, and four, 1 inch diameter spots of asphalt plastic cement per shingle and one spot of asphalt under each shingle tab, center of the shingle tab and 2 inches up from the bottom edge. Fasteners must be located in the center of the SureNail® fastening area. Maximum exposure to the weather must be 4 ±'/8 inches (102 ± 3 mm). In colder climates or wind regions where it is questionable whether the thermal -sealing adhesive will activate to seal the shingles, the shingles can be hand -sealed. A 1 -inch diameter (25.4 mm) spot of asphalt cement complying with ASTM D4586, Type I, Class I, should be placed under the corner 1 — 2 inches (25 — 51 mm) from each end of each tab (two spots per tab). Page 6 of 11 6.3.7 Laminated Shingles — TruDefinition® WeatherGuard® HP: For roof slopes of 2:12 up to 21:12 (16.67% or 9° up to 175% or 60°), each shingle must be fastened to the roof deck using a minimum of six fasteners. For roof slopes over 21:12 (175% or 60°), six fasteners must be used. Fasteners must be located 6-h/8 inches (157 mm) above the butt edge of the shingles. Maximum exposure to the weather must be 55/8 ± 1/8 inch (143 ± 3 mm). In colder climates or wind regions where it is questionable whether the thermal -sealing adhesive will activate to seal the shingles, the shingles can be hand -sealed. Four, 1 -inch diameter (25.4 mm) spots of cement should be placed under the exposed portion of the shingle, spaced 1 — 2 inches (25 — 51 mm) from each end of the shingle and two spots must be evenly spaced in between. 6.4 Valley Construction and Other Flashing: Valleys must consist of woven, open valley or closed -cut construction and must be flashed in accordance with Section 1507.2.9.2 of the 2012, 2009 and 2006 IBC or Section R905.2.8.2 of the 2012, 2009 and 2006 IRC. Other flashings must be in accordance with Sections 1503.2 and 1507.2.9 of the 2012, 2009 and 2006 IBC, or Sections R903.2 and 905.2.8 of the 2012, 2009 and 2006 IRC, as applicable. 6.5 Hip and Ridge Application: Hip and ridge shingles must be placed evenly over hips and ridges, and must be fastened to the roof deck using minimum two fasteners, one located on either side of the shingle, 1 inch (25.4 mm) up from the edge. Berkshire® Hip & Ridge Shingles, DuraRidge® Hip and Ridge Shingles and High Ridge Hip & Ridge with Sealant prefabricated hip and ridge shingles must be installed with a maximum exposure of 8 inches (203 mm). WeatherGuard® HP, ProEdge®, ProEdge Storm®, and RIZERidge® prefabricated hip ridge shingles must be installed with a maximum exposure of 6 inches (127 mm). Nailing for Hip and Ridge shingles are shown in application instructions. 6.6 Reroofing: The existing asphalt shingle roof covering must be inspected in accordance with the provisions and limitations of Section 1510 of the 2012, 2009 and 2006 IBC or Section R907 of the 2012, 2009 and 2006 IRC, as applicable. Prior to the reroofing, hip and ridge coverings must be removed. Except as noted in this section, the shingles must be installed in accordance with Section 6.3 and 6.5 of this Report. Fasteners must be of sufficient length to penetrate'/ inch (19.1 mm) into the sheathing, or through the sheathing where the sheathing is less than Y4 inch (19.1 mm) thick. Flashing and edging must comply with Section 6.4 and with Sections 1510.5 and 1510.6 of the 2012, 2009 and 2006 IBC and Sections R907.5 and R907.6 of the 2012, 2009 and 2006 IRC, as applicable. Page 7 of 11 7. INSTALLATION MATERIALS 7.1 Sheathing: The roof deck must be code -complying, minimum 3/8 -inch thick (9.5 mm), exterior plywood complying with DOC PS -1; rated sheathing complying with DOC PS -2; or solid sheathing using minimum nominally 1 by 6 lumber. 7.2 Underlayment: Under the IBC or IRC, underlayment must comply with ASTM D226, Type I, ASTM D4869, Type I or ASTM D6757 as specified in Section 1507.2.3 of the 2012, 2009 and 2006 IBC or IRC Section R905.2.3 of the 2012, 2009 and 2006 IRC 7.3 Self -adhering Polymer Modified Bitumen Sheet: When used as an underlayment under shingles described herein, self -adhering polymer modified bitumen sheet must comply with ASTM D1970. 7.4 Starter Shingles: The starter course shingle may consist of Woodstart ® Starter Shingle, Starter Strip Plus, Starter Strip Shingle, or Tri Built Starter Strip. If self-sealing three -tab shingles are used, remove the exposed tab portion and install with factory -applied sealant adjacent to the eaves. 7.5 Fasteners: Fasteners must be minimum No. 12 gage [0.105 inch (2.7 mm)], 3/8 -inch diameter head (9.5 mm), galvanized, stainless steel, aluminum or copper corrosion -resistance nails. Fasteners must be of sufficient length to penetrate into the sheathing min. 3/4 -inch (19.1 mm), or through the sheathing, where the sheathing is less than 3h -inch (19.1 mm) thick. Fasteners must comply with ASTM F1667. 7.6 Asphalt Cement: Asphalt cement must comply with ASTM D4586, Type I, Class I. 8. CONDITIONS OF USE The OWENS CORNING Asphalt Shingles described in this Report comply with, or are suitable alternatives to, what is specified in those codes listed in Section 2 of this Report, subject to the following conditions: 8.1 Materials and methods of installation shall comply with this Report and the manufacturer's published installation instructions. In the event of a conflict between the installation instructions and this Report, this Report governs. 8.2 The products are manufactured at the locations listed in Table 1 of this Report under the UL LLC Classification and Follow -Up Service Program, which includes audits in accordance with quality elements of ICC -ES Acceptance Criteria for Quality Documentation, AC10. 8.3 See UL Online Certifications Directory for Prepared Roof -Covering Materials (TFWZ and TGAH). Page 8 of 11 9. SUPPORTING EVIDENCE 9.1 Manufacturer's descriptive product literature, including installation instructions. 9.2 UL test reports and Classification in accordance with ANSI/UL 790, Class A and UL Subject 2375. See UL Product Certification Category for Prepared Roof -Covering Materials (TFWZ). 9.3 UL test reports and Classification in accordance with ASTM D3462. See UL Product Certification Category for Prepared Roof -Covering Materials (TFWZ). 9.4 UL Test reports and Classification in accordance with ICC -ES Acceptance Criteria for Alternative Asphalt Roofing Shingles, AC438 9.5 UL test reports and Classification in accordance with UL 2390/ASTM D7158, Class H. See UL Product Certification Category for Prepared Roof -Covering Materials (TGAH). 9.6 UL test reports and Classification in accordance with ASTM D3161, Class F. See UL Product Certification Category for Prepared Roof -Covering Materials (TFWZ). 9.7 Quality Documentation in accordance with ICC -ES Acceptance Criteria for Quality Documentation, AC10. See UL's On -Line Certification Directory for the following product categories referenced above: • TFWZ • TGAH 10. IDENTIFICATION OWENS CORNING asphalt shingles described in this Evaluation Report are identified by a marking bearing the report holder's name (OWENS CORNING), the plant identification, the product name, the UL Classification Mark and the evaluation report number ULER2453-01. The validity of this Evaluation Report is contingent upon this identification appearing on the product. . The UL Classification Mark shall indicate: a. UL790/ASTM E108 - Class A b. ASTM D3161 — Class F or Class A c. UL2390 (ASTM D7158) — Class H d. ASTM D3462 e. ICC -ES Acceptance Criteria, AC438 11. USE OF UL EVALUATION REPORT 11.1 The approval of building products, materials or systems is under the responsibility of the applicable authorities having jurisdiction. 11.2 UL Evaluation Reports shall not be used in any manner that implies an endorsement of the product, material or system by UL. 11.3 The current status of this report, as well as a complete directory of UL Evaluation Reports may be found at UL.com via our On -Line Certifications Directory: www.ul.com/erdirectory Page 9 of 11 Table 1 — Manufacturing Locations LISTEE LOCATION FACTORY ID OWENS CORNING 5201 FOX ST DENVER CO 80216 DENVER OWENS CORNING 704 CORRINE AVE N STATION MEMPHIS TN 38107 MEMPHIS OWENS CORNING 1249 NEWARK TPKE KEARNY NJ 07032 KEARNY OWENS CORNING 1901 49TH AVE N MINNEAPOLIS MN 55430 MINNEAPOLIS OWENS CORNING 128 W 8TH ST BROOKVILLE IN 47012 BROOKVILLE OWENS CORNING 1501 N TAMARIND ST PO BOX 5665 COMPTON CA 90224 COMPTON OWENS CORNING 8360 MARKET ST RD HOUSTON TX 77029 HOUSTON OWENS CORNING 201 N NURSERY RD IRVING TX 75061 IRVING OWENS CORNING 3750 NW YEON AVE PORTLAND OR 97208 PORTLAND OWENS CORNING 5824 S ARCHER RD SUMMIT IL 60501 SUMMIT OWENS CORNING 4795 FREDERICK DR ATLANTA GA 30336 ATLANTA OWENS CORNING 1035 TALLEYRAND AVE JACKSONVILLE FL 32206 JACKSONVILLE OWENS CORNING 890 W SMITH RD MEDINA OH 44256 MEDINA OWENS CORNING 1 FOUNDATION DR SAVANNAH GA 31408 SAVANNAH Page 10 of 11 © 2014 UL LLC This UL Evaluation Report is not an endorsement or recommendation for use of the subject and/or product described herein. This report is not the UL Listing or UL Classification Report that covers the subject product. The subject product's UL Listing or UL Classification is covered under a separate UL Report. UL disclaims all representations and warranties whether express or implied, with respect to this report and the subject or product described herein. Contents of this report may be based on data that has been generated by laboratories other than UL that are accredited as complying with ISO/IEC Standard 17025 by the International Accreditation Service (IAS) or by any other accreditation body that is a signatory to the International Laboratory Accreditation Cooperation (ILAC) Mutual Recognition Arrangement (MRA). The scope of the laboratory's accreditation shall include the specific type of testing covered in the test report. As the accuracy of any non -UL data is the responsibility of the accredited laboratory, UL does not accept responsibility for the accuracy of this data. Page 11 of 11 3/1/2017 City of Tukwila Department of Community Development KENT HAKOLA 20203 BROADWAY AVE SNOHOMISH, WA 98296 RE: Permit Application No. D16-0273 CITY OF TUKWILA - CITY HALL 6200 SOUTHCENTER BLVD Dear KENT HAKOLA, A -e Allan Ekberg, Mayor Jack Pace, Director In reviewing our current application files, it appears that your permit applied for on 10/11/2016, has not been issued by the City of Tukwila Permit Center. Per the International Building Code, International Mechanical Code, Uniform Plumbing Code and/or National Electrical Code every permit application not issued within 180 days from the date of application shall expire and become null and void. Currently your application has a status of APPROVED and is due to expire on 4/11/2017. If you still plan to pursue your project, you are hereby advised to do one of the following: 1) If the plan review is complete for the project and your application is approved, you may pick up the application before the date of expiration. At the time of permit issuance the expiration date will automatically be extended 180 days. -or- 2) If the plan review is not completed submit a written request for application extension (7) seven days in advance of the expiration date. Address your extension request to the Building Official and state your reason(s) for the need to extend your application. The Building Code does allow the Building Official to approve one extension of up to 90 days. If it is determined that your extension request is granted, you will be notified by mail. In the event that we do not receive your written request for extension or request is denied, your permit application will expire and your project will require a new permit application, plans and specifications, and associated fees. Thank you for your cooperation in this matter. Bill Rambo Permit Technician File No: D16-0273 6300 Southcen.ter Boulevard Suite #100 • Tukwila Washington 98188 • Phone 206-431-3670 • Fax 206-431-3665 PERMIT COORD COPY PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: D16-0273 DATE: 10/12/16 PROJECT NAME: CITY OF TUKWILA-CITY HALL SITE ADDRESS: 6200 SOUTHCENTER BLVD X Original Plan Submittal Response to Correction Letter # Revision # before Permit Issued Revision # after Permit Issued DEPARTMENTS: A -T kwc Building Division Public Works ❑ A-V' N/A 10-13-f� Fire Prevention Structural Planning Division ❑ Permit Coordinator PRELIMINARY REVIEW: Not Applicable n (no approval/review required) DATE: 10/13/16 Structural Review Required REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: DUE DATE: 11/10/16 Approved Corrections Required ❑ Approved with Conditions ❑ Denied (corrections entered in Reviews) (ie: Zoning Issues) Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire 0 Ping ❑ PW ❑ Staff Initials: 1208/2013 SNYDER ROOFING OF WASH LL Home Espanol Contact Safety & Health Claims & Insurance Washington State Department of , Labor & Industries A -L Index Help Page 1 of 3 My L&I Workplace Rights Trades & Licensing SNYDER ROOFING OF WASH LLC Owner or tradesperson Principals PICCOLI, DALE A, MANAGER MULLEN, JOSHUA F, MANAGER GARDNER, J TIMOTHY, PARTNER/MEMBER (End: 05/18/2009) KING, SCOTT G, PARTNER/MEMBER (End: 05/18/2009) STMARTIN, CHRISTIE, PARTNER/MEMBER (End: 05/18/2009) GARDNER, JOSEPH TIMOTHY, MANAGER (End: 05/20/2015) KING, JAMES F, PARTNER/MEMBER (End: 05/28/2013) SNYDER ROOFING & SHEET METAL I, PARTNER/MEMBER (End: 05/28/2013) MYERS, DAVE, PARTNER/MEMBER (End: 05/28/2013) GARRICK-PICCOLI, DANEEN, PARTNER/MEMBER (End: 05/28/2013) PICCOLI, DAVE, PARTNER/MEMBER (End: 05/28/2013) STEPHENSON, GUY, AGENT (End: 05/28/2013) KING, KYLE R, MANAGER (End: 06/05/2015) Doing business as SNYDER ROOFING OF WASH LLC WA UBI No. 601 961 354 20203 BROADWAY AVE SNOHOMISH, WA 98296 425-402-1848 SNOHOMISH County Business type Limited Liability Company Governing persons DALE R PICCOLI JAMES F KING REVOCABLE LIVIN; JOSHUA MULLEN; License Verify the contractor's active registration / license / certification (depending on trade) and any past violations. Construction Contractor Help us improve https://secure.lni.wa.gov/verify/Detail.aspx?UBI=601961354&LIC=SNYDERW014MT&SAW= 3/24/2017 SNYDER ROOFING OF WASH LI Page 2 of 3 Active. Meets current requirements. License specialties GENERAL License no. SNYDERW014MT Effective — expiration 07/30/1999— 06/05/2017 Bond ................. WESTERN SURETY CO Bond account no. 929186510 $12,000.00 Received by L&I Effective date 06/03/2004 05/18/2004 Expiration date Until Canceled Insurance ........... National Fire Ins of Hartford Policy no. 5092135452 $1,000,000.00 Received by L&I Effective date 04/11/2016 05/01/2015 Expiration date 05/01/2017 Insurance history Savings ........................ No savings accounts during the previous 6 year period. Lawsuits against the bond or savings No lawsuits against the bond or savings accounts during the previous 6 year period. L&I Tax debts No L&I tax debts are recorded for this contractor license during the previous 6 year period, but some debts may be recorded by other agencies. License Violations No license violations during the previous 6 year period. Workers' comp Do you know if the business has employees? If so, verify the business is up-to-date on workers' comp premiums. L&I Account ID 201..,021-01 .............................. Doing business as SNYDER ROOFING OF WASHINGTON Estimated workers reported Quarter 4 of Year 2016 "Greater than 100 Workers" L&I account representative T2 / KATHY ULRICH (360)902-4829 - Email: WITE235@Ini.wa.gov Account is current. Workplace safety and health Check for any past safety and health violations found on jobsites this business was responsible for. Inspection results date 02/18/2016 Inspection no. 317938991 Location 206 3rd Avenue south Seattle, WA 98104 Inspection results date 01/29/2016 Inspection no. 317938985 Violations No violations Help us improve https://secure.lni.wa.gov/verify/Detail.aspx?UBI=601961354&LIC=SNYDERW014MT&SAW= 3/24/2017