Loading...
HomeMy WebLinkAboutPermit D16-0274 - SOUTHCENTER WEST BUSINESS PARK - DOCK LEVELERSThis record contains information which is exempt from public disclosure pursuant to the Washington State Public Records Act, Chapter 42.56 RCW as identified on the Digital Records Exemption Log shown below. D16-0274 SOUTHCENTER WEST BUSINESS PARK 1141 ANDOVER PARK W RECORDSDIGITAL D-) EXEMPTION LOG THE ABOVE MENTIONED PERMIT FILE INCLUDES THE FOLLOWING REDACTED INFORMATION Page # Coda Exemption, � � � I3ri6f Explanatory 6escrlofion, Sfatutte/Ruilo The Privacy Act of 1974 evinces Congress' intent that social security numbers are a private concern. As such, individuals' social security Personal Information — numbers are redacted to protect those Social Security Numbers individuals' privacy pursuant to 5 U.S.C. sec. 5 U.S.C. sec. DR1 Generally — 5 U.S.C. sec. 552(a), and are also exempt from disclosure 552(a); RCW 552(a); RCW under section 42.56.070(1) of the Washington 42.56.070(1) 42.56.070(1) State Public Records Act, which exempts under the PRA records or information exempt or prohibited from disclosure under any other statute. Redactions contain Credit card numbers, debit card numbers, electronic check numbers, credit Personal Information — expiration dates, or bank or other financial RCW 22 DR2 Financial Information — account numbers, which are exempt from 42.56.230(5) RCW 42.56.230(4 5) disclosure pursuant to RCW 42.56.230(5), except when disclosure is expressly required by or governed by other law. Personal Information — Redactions contain information used to prove RCW DR3 Driver's License. — RCW identity, age, residential address, social security 42.56.230 (7a 42.56.230 number or other personal information required to & c) (7a & c) apply for a driver's license or identicard. Redacted content contains a communication between client and attorney for the purpose of obtaining or providing legal advice exempt from RCW Attorney -Client Privilege — disclosure pursuant to RCW 5.60.060(2)(a), 5.60.060(2)(a); DR4 RCW 5.60.060(2)(a); RCW which protects attorney-client privileged RCW 42.56.070(1) communications, and RCW 42.56.070(1), which 42.56.070(1) protects, under the PRA, information exempt or prohibited from disclosure under another statute. SOUTHCENTER WEST BUSINESS PARK 1141 ANDOVER PARK W EXPIRED 05/27/17 D16-0274 Parcel No: Address: Project Name: City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-438-9350 Web site: http://www.TukwilaWA.eov DEVELOPMENT PERMIT 3523049098 Permit Number: 1141 ANDOVER PARK W SOUTHCENTER WEST BUSINESS PARK Issue Date: Permit Expires On: D16-0274 11/28/2016 5/27/2017 Owner: Name: Address: Contact Person: Name: Address: Contractor: Name: Address: License No: Lender: Name: Address: ICON OWNER POOL 1 WEST LLC 2 N RIVERSIDE STE 2350, CHICAGO, WA, 60606 MARK SANDERS PO BOX 1218 , MAPLE VALLEY, WA, 98038 COAST TO COAST CONCRETE PO BOX 1218 , MAPLE VALLEY, WA, 98038 COASTCC011PL Phone: (253) 261-2069 Phone: (425) 432-1347 Expiration Date: DESCRIPTION OF WORK: INSTALL (4) DOCK LEVELERS Project Valuation: $24,000.00 Type of Fire Protection: Sprinklers: Fire Alarm: Type of Construction: Electrical Service Provided by: TUKWILA Fees Collected: $957.70 Occupancy per IBC: Water District: TUKWILA Sewer District: TUKWILA Current Codes adopted by the City of Tukwila: International Building Code Edition: International Residential Code Edition: International Mechanical Code Edition: Uniform Plumbing Code Edition: International Fuel Gas Code: 2015 2015 2015 2015 2015 National Electrical Code: WA Cities Electrical Code: WAC 296-46B: WA State Energy Code: 2014 2014 2014 2015 Public Works Activities: Channelization/Striping: Curb Cut/Access/Sidewalk: Fire Loop Hydrant: Flood Control Zone: Hauling/Oversize Load: Land Altering: Landscape Irrigation: Sanitary Side Sewer: Sewer Main Extension: Storm Drainage: Street Use: Water Main Extension: Water Meter: Volumes: Cut: 0 Fill: 0 Number: 0 Permit Center Authorized Signature: Date: 1 1—.4—I 41 I hearby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this development t and a}ee to the •nditions attacheto this permit. Signature: Print Name: ek- snNprO— Date:1 This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: ***BUILDING PERMIT CONDITIONS*** 2: Work shall be installed in accordance with the approved construction documents, and any changes made during construction that are not in accordance with the approved construction documents shall be resubmitted for approval. 3: All permits, inspection record card and approved construction documents shall be kept at the site of work and shall be open to inspection by the Building Inspector until final inspection approval is granted. 4: All construction shall be done in conformance with the Washington State Building Code and the Washington State Energy Code. 5: Notify the City of Tukwila Building Division prior to placing any concrete. This procedure is in addition to any requirements for special inspection. 6: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of this requirement. 7: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206-431-3670). 8: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center. 9: Preparation before concrete placement: Water shall be removed from place of deposit before concrete is placed unless a tremie is to be used or unless otherwise permitted by the building official. All debris and ice shall be removed from spaces to be occupied by concrete. 10: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 1700 BUILDING FINAL** 0301 CONCRETE SLAB 0200 FOUNDATION WALL 4046 SI-EPDXY/EXP CONC CITY OF TUKWILA Community Development Department Public Works Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.TukwilaWA.gov Building Permit No. -blip - (../1 ` Lf Project No. Date Application Accepted: ` I ((0 Date Application Expires: 1+1 (For office use only) CONSTRUCTION PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **Please Print** SITE LOCATION A/961 �� , - / King Co Assessor's Tax No.: Site Address: / /q / >f -t /9d jY Y'' f 2I VV �f n Suite Number: Bid Floor. I '+ Tenant Name: Sotc ceirier-we -f& sine Por PROPERTY OWNER Name: mare, Sand erg Address: PD , a 0 x `y s, Name: Phone:(23321 qFax( 5)f 3 43 Email' 7%'O 3cpCOrnG'Gj ..-iyp Address: City: State: Zip: CONTACT PERSON - person receiving all project communication Name: mare, Sand erg Address: PD , a 0 x `y s, CityMap/„i/Q// State: j/i/A Zip:97a 3sy Phone:(23321 qFax( 5)f 3 43 Email' 7%'O 3cpCOrnG'Gj ..-iyp -O)6c, GENERAL CONTRACTOR INFORMATION Company Name: 60.5./. ,to 66,66*6..„,a, Address: Po..dox 1.2./ g City: %State: WA Zip:ggro3S 4,0/.. V- ' 1 •�// � Phone (.J -)1)31 _ x` ' Fax:L?Z5-) 413_0373 J Contr Reg No.:&*7 1ipjExp Date: 06117 Tukwila Business License No.: BaS - o 9 q 7129 t>:\ApplicatiomUUnnm-Applications On L nc\2011 Application!\Pctmit Application Rcviacd - 8-9-I I.dncx Reviscd: August 2011 New Tenant: El Yes ❑ ..No ARCHITECT OF RECORD Company Name 4et Ke _A Arm , t itts Architect Name: ay! -4,K Address: /eli& ?&nal r zr Yr' City:s> it State: 1,4 I1Zip: 9Se) Phone:(2069) I/33 4Q7Fax:(20&) 24/4, - g.3Co% / Email: ENGINEER OF RECORD Company Name: Ram ze'-1 n i. e l h al ti - Engineer Name: (parr 1 led Can i Address:412 v1/16..t )YrJad wa ) .0 20,4 city: 6 / 4a , State: q Zip: 9/204 Phone:(Q l..r,/) 1()2 3V gb Fax: (g l g) 240 -3 &13 o '�✓ ! Email: LENDER/BOND ISSUED (required for projects $5,000 or greater per RCW 19.27.095) Name: Address: City: State: Zip: Page 1 of 4 BUILDING PERMIT INFORMATIC 206-431-3670 Valuation of Project (contractor's bid price): $ 24/Nra.) Existing Building Valuation: $ - Describe the scope of work (please provide detailed information): /ns9�l� (V) dock 1-,l/elet s Will there be new rack storage? ❑ Yes 4.. No if yes, a separate permit and plan submittal will be required. L Provide All Building Areas in Square Footage Below PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact: Handicap: Will there be a change in use? ❑ Yes ❑ No If "yes", explain: FIRE PROTECTION/HAZARDOUS MATERIALS: ❑ Sprinklers 0 Automatic Fire Alarm ❑ None ❑ Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes ❑ No If "yes', attach list ofmateriaLs and storage locations on a separate 8-1/2"x 11 "paper including quantities and Material Safety Data Sheets. SEPTIC SYSTEM 0 On-site Septic System — For on-site septic system, provide 2 copies of a current septic design approved by King County Health Department. H: ApplicatiomlForns-Applirbtions On Line \201 I Applicatiom4Permil Application Revised - 8-9-11.doex Revised: August 2011 bh Page 2 of 4 Existing Interior Remodel Addition to Existing Structure New Type of Construction per IBC Type of Occupancy per IBC 161 Floor 30/ ra rd Floor 3rd Floor Floors thru Basement Accessory Structures Attached Garage Detached Garage Attached Carport Detached Carport , Covered Deck Uncovered Deck PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact: Handicap: Will there be a change in use? ❑ Yes ❑ No If "yes", explain: FIRE PROTECTION/HAZARDOUS MATERIALS: ❑ Sprinklers 0 Automatic Fire Alarm ❑ None ❑ Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes ❑ No If "yes', attach list ofmateriaLs and storage locations on a separate 8-1/2"x 11 "paper including quantities and Material Safety Data Sheets. SEPTIC SYSTEM 0 On-site Septic System — For on-site septic system, provide 2 copies of a current septic design approved by King County Health Department. H: ApplicatiomlForns-Applirbtions On Line \201 I Applicatiom4Permil Application Revised - 8-9-11.doex Revised: August 2011 bh Page 2 of 4 PUBLIC WORKS PERMIT 1NFC IATION — 206-433-0179 Scope of Work (please provide detailed information): Call before you Dig: 811 Please refer to Public Works Bulletin #1 for fees and estimate sheet. Water District ❑ ...Tukwila ❑...Water District #125 ❑ ...Water Availability Provided Sewer District ❑ ...Tukwila ❑ ...Sewer Use Certificate ❑ ...Valley View ❑ ... Sewer Availability Provided ❑ .. Highline ❑ .. Renton ❑ .. Renton ❑ .. Seattle Septic System: 0 On-site Septic System — For on-site septic system, provide 2 copies of a current septic design approved by King County Health Department. Submitted with Application (mark boxes which apply): ❑ ...Civil Plans (Maximum Paper Size — 22" x 34") ❑ ...Technical. Information Report (Storm Drainage) ❑ ...Bond ❑ .. Insurance ❑ .. Easement(s) Proposed Activities (mark boxes that apply): ❑ ...Right-of-way Use - Nonprofit for less than 72 hours ❑ ...Right-of-way Use - No Disturbance ❑ ...Construction/Excavation/Fill - Right-of-way ❑ Non Right-of-way ❑ ...Total Cut ❑ ...Total Fill cubic yards cubic yards ❑ ...Sanitary Side Sewer ❑ ...Cap or Remove Utilities ❑ ...Frontage Improvements ❑ ...Traffic Control ❑ ...Backflow Prevention - Fire Protection _ Irrigation Domestic Water ❑ ...Permanent Water Meter Size... ❑ ...Temporary Water Meter Size .. ❑ ...Water Only Meter Size " ❑ ...Sewer Main Extension Public ❑ Private ❑ ❑ ...Water Main Extension. Public ❑ Private ❑ ❑ .. Geotechnical Report ❑ .. Maintenance Agreement(s) ❑ ...Traffic Impact Analysis ❑ ...Hold Harmless — (SAO) ❑ ...Hold Harmless — (ROW) ❑ .. Right-of-way Use - Profit for less than 72 hours ❑ .. Right-of-way Use — Potential Disturbance ❑ .. Work in Flood Zone ❑ .. Storm Drainage ❑ .. Abandon Septic Tank ❑ .. Curb Cut ❑ .. Pavement Cut ❑ .. Looped Fire Line ft >> WO # WO # WO # ❑ .. Grease Interceptor ❑ .. Channelization ❑ .. Trench Excavation 0 .. Utility Undergrounding ❑...Deduct Water Meter Size ff FINANCE INFORMATION Fire Line Size at Property Line ❑ ...Water ❑ ...Sewer 0 ...Sewage Treatment Monthly Service Billing to: Name: Number of Public Fire Hydrant(s) Day Telephone: Mailing Address: City State Zip Water Meter Refund/Billing: Name: Mailing Address: Day Telephone: City State Zip HMppli atiorniForms-Applications On Line\201 I Applications\Permit Application Revised - R-9-1 I.docx Revised: August 2011 bh Page 3 of 4 PERMIT APPLICATION NOTES — Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND 1 AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILD1NGM AUTRIZNT: Signature: Print Name: fV7Sanciag Mailing Address: Po . 60x i z i g Date: 10/100 C -e1 I (25.3 1 2z &c Day Telephone: HAApplieationsWonns-Applications On Line \201 I Applications\Permit Application Revised - SA -I I.docx Revised: August 2011 bh #-32-1341 Male,Va 1 Lexi WA 9','038' civ Slate Zip Page 4 of 4 Cash Register Receipt City of Tukwila DESCRIPTIONS ACCOUNT QUANTITY PermitTRAK PAID $957.70 D16-0274 Address: 1141 ANDOVER PARK W Apn: 3523049098 $957.70 DEVELOPMENT $929.66 PERMIT FEE R000.322.100.00.00 0.00 $560.70 PLAN CHECK FEE R000.345.830.00.00 0.00 $364.46 WASHINGTON STATE SURCHARGE B640.237.114 0.00 $4.50 TECHNOLOGY FEE $28.04 TECHNOLOGY FEE TOTAL FEES PAID BY RECEIPT: R9613 R000.322.900.04.00 0.00 $28.04 $957.70 Date Paid: Tuesday, October 11, 2016 Paid By: DIANE BILLEDO Pay Method: CREDIT CARD 08849G Printed: Tuesday, October 11, 2016 12:41 PM 1 of 1 r1111?7'111rSYSTEMS 1 - By G. GHANIAN DATE. 10-5-16 SUBJECT IZAdK DEOIC N & ENOINEERINGt do. 412 TET BROADWAY, WUITE #204 OUNDALE, dA. 91204 TEL4818)240-3810 FAX:(818)240-3813 DOCK LEVELEE�U PIT DITAILS FOR: SQUTHCENJTER Vi°EST BUSINESS RARK 1 147 ANDOVER PA RK WEST. BLDG. C TUKWILA. WA J35" SHEET NO. 1 OF 3 JOB NO. RD -18699 riXPIREB 12-26-17 x157I1,4 sUILr›ING DOCK LEVELER FIT - PLAN vim 51� RUC_: AL NOTES: 4) CONCRETE TO ATTAIN A 28 DAY COMPRE 51VE &TRENGT1-I OF 2500 1=51. 2) REINFORCING 514,44.L CONF! FR11 TO ASTM A-Ca15 GRADE 40 OR blV. 3) FINAL CONCRETE 5URFACi'5 SHALL HAVE A FINISH SIMILAR TO Exl5TIN"x SURFACES, 4) !PROVIDE A 3" MIN, COVE covEFi TO ALL RESAR 5) FOR PIMEN&ION5, CURB Ai•IGLES AND INSERT PUMPERS SEE MANU=AGTUFE'S ORAI.ING AND sPEGIFICATION6 0,) NO 61FEC AL INSIPECTION S REQUIRED NBIS3G )iDV I �'��� �z [•: LEf NCE. LL CCT 2 5 HA City of Tukwila BUi DUG f (visioN RECEIVED CITY Of: TUKWILA OCT 1 1 2016 PERM T CENTER DI(p O2.i4 ET9E-OiZ-8T8 95:9T 9T2Z/E010T BY G. OHANIAN DATE . 10-5-'16 SUBJECT 6" ]ACK DEMON & ENOINEERINC4 Co. 412 WV BROADWAY, QUITE #204 (LENDALE, OA. 91204 TEL:(818)240-9810 FAX:(818)240-3813 EXISTING PLR SLAB IN Eh1Ei. PIT FLOOR GURE3 ANGLE !may 3X3X3/Ie," -+44 RE15AF2, CONTINUOUS, TYP. *4 RE8ARS AT 12"oz, E11). PIT WALL SHEET NO. 2 JOB NO.. RD -18699 I II i9III .14= Il I E0 3Jdd 11-11. =111 11=111=A 11=111 SECTION A CURS ANGLE PER 3X3x3/16" 9L =J11; 1 EXISTING SLAB FLOOR ,s. NEW F'1T UJALL *4 BEAR. GONTINUOUS, TYP. *4 RE5ARS AT 12"v_c. 11 111 .1111�'1111_11r` 111,N MI NEW pIT FLOOF= 61_5 W/1/2" SLOPE —EXISTING aUILPING WALL SECTION 5 NEIS3G >1Dde1 ET9E-0I'-8T8 95:9T 9ToZ/E0/0T BY G. OHAN IAN DATE. 10-5-16 SUBJECT ifi "Al= Ill I� norA ILII I 170 39Vd If r 1: IL II II l ACK DENT N & ENC INEERIN(4 d0. 412 WEBTBROADWAY, QUITE #204 LENDALE, CIA. 91204 TEL:(818)240-3810 FAX:(818)24O-3813 04 1 E ARE AT 12 "o.c. E. U EXIBTING WALL SHEET NO 5 JOB NO. RD -18699 ]ILII in �l a rr riagl r"i irr ILrr- l.uLrrl3'�- . . e . .01 81" _ 0,4 R€ 5ARS AT 12"ac_ E.W. NEW PIT FLOOR SLAB ( ANC"sLE In (53 CURB 3x7c3/I6, —„ -1ul I '�••� ,!1 " X11' 1 SII `ll 1-11dll1=1II"II 11 TOS' vIEW NJIS3G >10tie1 ET8E-017Z-818 95 :ST 9T0ZIE0f0i .. —1.11 Tel MO-. V WL Mechanical DOCK LEVELER SPECIFICATIONS 30K -35K LB. (13.6-15.8 KG) CAPACITY RATINGS Design Highlights • Patented SafeTFrameTM Design • Exclusive POSI-TRAC® Unlimited Float Hold down • Unique HYDRA CAMTM Automatic Lip Extension • CLEAN FRAME® Design • Single Adjustment Point Extension Spring Counterbalance • High Tensile Steel Lip, Deck & Beams • Structural Steel Safety Legs • Working Range Toe Guards • Below -dock Endloading Capability • 16" Lip Standard (406 mm) • Grease Fittings • Integral Maintenance Strut & Lip Support Latch • Heavy-duty B410 -14F Dock Bumpers • Reduced Lip Crown/Extended Lip Chamfer Project Information Job Name Address General Contractor Distributor Model Quantity Certified For Construction By Company Address Date Available Options ❑ Factory Installed Brush Weatherseal ❑ Factory Installed Neoprene Weatherseal ❑ ENERGY GUARD® Perimeter Weatherseal System ❑ 18" Lip (457 mm) ❑ 20" Lip (508 mm) ❑ 24" Pit Conversion (610 mm) ❑ Spray Foam Insulated Deck ❑ Special Paint Color ❑ Full Operating Range Toe Guards ❑ High Lip Crown ❑ Lip Taper (specify) ❑ Box Option: For installation without pre -formed concrete pits, dock leveler supplied with integral pre -formed steel box for pour -in-place construction. Leveler shall be in an enclosed steel box structure complete with its own six -piece, welded structural curb angles and concrete anchors. The leveler is to be concreted in place as the floor is poured. ❑ Other Box Option Accessories o PitBull® SAFETY -LOC® Restraint ❑ SLP Recessed Restraint ❑ MANUAL SAFETY -CHOCK Wheel Restraint ❑ SAFETY -CHOCK® Wheel Restraint ❑ Universal Truck-ChockTM Wheel Restraint ❑ ALS Light Communication System ❑ MLS Light Communication System Bumper Options o 8410-14 0 VB420-11F O 8610-14 0 VB420-11 Steel Faced O B610 -14F 0 Other Capacity O 30K lb (13.6 Kg) 035K lb (15.8 Kg) 1612 Hutton Drive, Suite 140 • Carrollton, TX 75006, USA • Tel: 800-933-4834 • Fax: 972-389.4769 • Email: sales@sercocompany.com • www.sercocompany.com A continuing research program is in effect at Serco. We reserve the right to Incorporate product improvement at any time without prior notice. `m 2011 4Front Engineered Solutions, Inc. Porm#:SPS-DMWL-0511 4 WL Mechanical DOCK LEVELER SPECIFICATIONS 30K -35K LB. (13.6-15.8 KG) CAPACITY RATINGS 1. General: "WL" Series hinged lip dock leveler with extension spring counterbalance assembly. Unit conforms to ANSI/MH14.1-1987 performance requirements. Unit to be manufactured by Serco. 2. Construction, Platform Assembly: Platform constructed of high tensile steel safety tread deck plate supported by unique L -beam construction. Structural members fully welded to front header. Deck to be W (6 mm) thick. 3. Lip Assembly: Lip to be 16" (406 mm) high tensile steel safety tread lip plate with beveled leading edge. Lip to be %" (16 mm) thick on 30K & 35K lb. (13.6 & 15.8 Kg) capacity units. 7' (2.13 m) wide lip tapers to 6'-6" (2.01 m) at leading edge (6'-0" (1.83 m) taper optional). Lip hinge to have full width structural front header and heavy wall tubing with a minimum of 5/i6" (406 mm) wall thickness. Hinge tubes to have gussets on 35K lb. (15.8 Kg) capacity. Up hinge shaft to be a minimum of 1° (25 mm) solid steel. 4. Lip Extension: Patented HYDRA CAM," lip assist mechanism provides gentle lip activation and reduced walk -down loads. 5. Rear Subframe & Hinge: Rear structural frame consists of a welded structure constructed from 4 structural angle vertical members connecting two horizontal members. The upper rear angle has longitudinal support gussets & additional deck supports to promote structural stiffness. The hinge system consists of four a/4" (19 mm) thick lugs allowing 4" (100 mm) of side to side deck twist. 6. Saf.TFram&1': Adjustable shim system consisting of four independently operated leveling feet capable of 1-1/2 inches (37.5 mm) of vertical adjustment each. System eliminates the need for installer to place and weld steel shim stock under the vertical uprights providing more consistent installation thus preventing a gap or (bump) between the rear transition angle and curb angle. 7. Connderbaiance: Oil -tempered chromium silicon steel extension spring counterbalance with single adjustment point for high strength, durability, and easy walk -down. 8. Product Finnish: Enamel gray finish. 9. CLEAN FRAME*: Unique design allows access for easy pit clean out and routine maintenance. 10. "Nita -Lodz": Permanent "Nice -Lock" to prevent unauthorized entry beneath locked overhead door is standard. 11. Toe Guard Protection: Working range toe guard protection is provided on both sides of the leveler. Yellow OSHA required markings IAW ANSI Z535.1 provided on the sides of the dock leveler. 12. Safety Legs: Structural safety legs provide emergency support should a truck depart with a load on the leveler platform. Design incorporates cam mechanism to limit interference from truck float. 13. Integral Maintenance Strut & Lip Support Latch: A permanently mounted, hinged, lockout capable maintenance strut and lip support latch are provided to support the lip and leveler during routine maintenance and pit cleaning. 14. Below -dock Control (Enctoedins): Front mounted pull -chain facilitates below -dock endloading. 16. Out of Level Compensation: Leveler platform is designed to compensate for canted truck beds up to 4" (100 mm) and rear edge remains flush with the pit to eliminate pinch points. 16. Float Compensation: Allows for vertical carrier deflection when lip is in contact with truck bed. 17. Operation: Serco's "WL" mechanical leveler shall be supplied completely assembled with platform and lip mechanism and ready for use. Leveler to be operated by pulling release ring at rear of ramp; unit will raise, and lip will extend and hold. No manual lifting required. Unit shall be powered by extension springs with a single adjustment point. Operator to walk ramp down to truck bed. POSI-TRAC• hold-down shall hold unit in position. Unit will float with truck movement. Working range to be 12" (305 mm) above -dock and 12" (305 mm) below -dock for 6' (1.83 m), 8' (2.44 m), and 10' (3.05 m) long units. The lip extends a minimum of 11" (279 mm) beyond the face of a 4" (100 mm) bumper. After loading/unloading is complete, operator pulls and holds release chain until lip clears the truck bed. As leveler raises, lip will descend in a smooth, controlled manner. In stored position, ramp is fully supported by lip keepers. 18. Installation: Unit shipped completely assembled and ready for installation in pre -formed concrete pit. Pit depth is 20" (508 mm) for 6' (1.83 m) and 8' (2.44 m) long units, 24" (610 mm) for 10' (3.05 m) long units. Pit construction to be in accordance with certified Serco pit detail drawings. Contact Serco for current cost and nearest distributor. 19. Limited Warranty: Limited parts & labor warranty on all components under normal use for a 1 -year "Base Warranty Period" beginning on the completion of installation orthe sixtieth (60th) day after shipment, whichever is earlier. Additional limited 4 -year parts only warranty on main springs. Limited prorated 10 -year structural warranty available upon engineering approval of written application. 20. Boatmen: Unit to include two model 8410-14F (4" Thick x 14" W x 10" H) (100 mm x 356 mm x 254 mm) heavyduty bumpers. NOMINAL DIMENSIONS MODEL WIDTH LENGTH W1600 WL66.500 WL6700 WL800 WL86.500 WL8700 WL1000 WL106.500 WL1070O 6' (1.83 m) 6'6" (2.01 m) 7' (2.13 m) 6' (1.83 m) 6'6" (2.01 m) 7' (2.13 m) 6' (1.83 m) 6'6" (2.01 m) 7' (2.13 m) 6' (1.83 m) 6' (1.83 m) 6' (1.83 m) 8' (2.44 m) 8' (2.44 m) 8' (2.44 m) 10' (3.05 m) 10' (3.05 m) 10' (3.05 m) *24" (610 mm) pct depth standard on 10' (3.05 m) dock levelers 1612 Hutton Drive, Suite 140 • Carrollton. TX 75006. USA • Tel: 800,333.4834 • Fax: 972-389-4769 • Email: salesesercoccmpany.com • www.sercocompanycom A continuing research program is In effect at Serco. We reserve the right to Incorporate product Improvement at any time without prior notice. 0 20114Front Engineered Solutions, Inc. Forms:SPSOMWL-0511 FILE COPY ty;2iLf Perr": Plan revio:•,° Approval c: the violation: of approve' <F.'bject to errors and omissions. f'ocuments does not authorize ..;pted wife or ordinate. Receipt apy and ��o ons is acknowledged: _ t CE3 t1' Date: 4j J2 ;Il, City of Tukwila • BUILDING DIVISION 11'-16' 1�1 OF; OF•V10+D-4 ANIS NNG • 0 OCCF EPGLE EXR I95'-5' SEPA T E PERMIT REOar ED FOR: 'Mochanicat _QrElectricat , Plumbing ,'Gas Piping kwila BUILDING DIVISI DJAMIHNW 5B11 -HEATED MAX 44 D MAX 6 511114 / Bf RACCMG DT TENANT BEPARATE PERMIT 24,503 6F I I1500.4S OCCUPANTS BEE ELOW IJP SHEET T-2 F u I, ® ' II II INSPECTION SHALL BE REQUIRED TO VERIFY DRILLED HOLE PREPARATION AND CLEANING, PRIOR TO INSTALLATION OF EPDXY AND RE -BAR (OR IF APPLICABLE) INSTALLATION OF WEDGE ANCHOR BOLTS. INSPECTION VERIFICATION SHALL BE INCLUDED WITH CONCRETE INSPECTIONS. ANCHOR BOLT INSPECTIONS MAY BE I CLUDED WITH FRAMING INSPECTIONS. r y® • EX SHEAR WALL NEW DOCK LEvvLER PRS SEE PETAL, TIP 4 PLACER 50,U EDGE Cf DOCK LEVELER TUT 5 PLACED ® ® EX RAMP 13'-51' &L 65111-14EATED MAX 44 D MAX 6 ETIJN / BF RACKING CT TENANT SEPARATE PEIW 11T 9950 Ef • V500 • It OCC. II MLWOZEQWM BETH -HEATED MAX 44 MAX 6 STUN / EP RACKING ET TENANT BEPARATE f5R'tlT 11,136 SF • J560 . 24 OCC, REMOVE PORTION OF �EXI51 s PE115V6 ELA.L WO( TO EX CONN �TEANT OVERALL FLOOR PLAN SCALE: VW • r -B+" 4!0' TENANT AREA r--r-- r 12?' -31' 5EE !LOW LF SHEET T-2 5811 -HEATED MAX 44 D MAX 5 MN / Of RACK56 6T TENANT SEPARATE PEIBIIT 14916 EF • 1/500. 75 OCG CE AREA 1.953 EF • V100 ' 8 OCCUPANTS SMGLE EXIT CfFICE MEd 1.1540 5F . VIOL . SINGLE ExrT EX NEAR WALL 7 ® 110 R CODE COMPLIANCE APPROVED OCT 2 5 201 p) City of Tukwila BUILDING DIVISION rd v g v," v. br- 7 7 RECEIVa 7/ ////0 y . . . • . CITY OF TU / OCT 1 1 0 A, 14 I�1;�A! PERMIT - 41/Ar .:. ri 1// It. 1 i Arc ---gip REVISIONS No changes shall be made to the scope of workout prior approval of Tukov I- !ding Division. NOTE: Revisio , ill quire a new plan submittal and may include additional plan review fees. AREA OF UJORK 11/11 11/ I@ SOUTF{CENTER W13USN{=ARK VERALL PLAN 1141 ANDOVER PAESTRK WESIT BSSUILDINGPCO TUKWILA WASNINGTGN D WILA 316 TER i y�r- E" D%i —OZ'14� O D.omfrn. rid SrinpW U..ntd,oun.nhlCAOt20021022:1 OVA.IOA:BaMwntr W.r S14n8. PrkW T!RLIN! SLOG CiPIP ZTA e.,' Lt 2.i0talb317 PM MIXED-USE, NON -SEPARATED USES (SECTION 501)1 TYPE CP OON41111Cl 4 IT -I MUT eP141IQ. ) 1GL41112.TOR/ 1Ill010.1$11001ICED DY f0' Oral awe Al 44 E& (SWUM ASSESSOR PARCEL NUhESER 14544114 LEGAL DESCRIPTION NICE. a. sena a COR CF MI VIM 0E I/4 OP Sec 4441-4 4 FM NO 44 OF IE 44 OF BEC 705-4 DDI ATNF OAF OF NI W OF IE W IEC 10141401.44.4life A iN N 41.71 E 44L1 1.14 OP4C0op MKOIINFTTIN 01.1.RBM1FT TO 70011114 01.1.0! 4411.11T 11IeI-41411144CFTTOAI AOL! Pt 1$111Plet411.113FNI-300.40)NR 11414 11.100 440.114144 KT N A 001A1310 LN 10I141 TO TFCC UM LLT 746 PT G 9 OC P I- 30-44. 15UILDNG AND SITE STATISTICS: =DM CLOD DC 7[000F III STATE A1Sp'@714 11C CTNOLIA ~PI COM O 7614.0P. (414 AC) VOW AP. en! Alia AMAX 5)00124444 !CM 144441 OPALS AIE 10F 141446 CMS U. 30006. OKVOCT GI AEO CC LOAD& D CAPKi) IA* U. / NEC • 1 OCC7pANt0 61 /UWI5M!) 44)05 Op. / 000 • 44 OCCO•An6 TOTAL =PIM • 144 Et0P103 110 bole ARe Iig11iD AC TIC COS APE PIWO® d EId eOEC YEAR 011 TYPE OP CA1PPLIC1108 Old (FILLY IHO1C®I saustazearacuamm.44 4010 CPPC16 x5644 a.. WOW . Sp awn REAL Ne419 v... atom • Ier 5PAC6e UNE. . M466A 1R .1(0000 • 44 SPACE* as :Naas FANKPIG PACO PIOIIDm ID 4401100 RAMO OPACi0 NCI CN40E) SCOPE OF WORK: 44124 4401TP0NON-044114 a#CE NRI11104. MINE 5)00100 TORPCO , 4451! COMM OJIP. ACOU$TC C44LI0 N CAD OPMICX AREA AND =MAW 15.4:3C TO IMMO! SEPERATE PERMITS e RTl114R IIIA tECINC ., FI! ALAI%RVePC. MER CAMP 1011 1176.4. 10LD542e LLC CIO RWDe ML1ID6 F11141L• bA L{ wOVER iw. Y+ren FW 40.610. OI -D VICINITY MAP N lout, :era BLDG E I WO D AEA CF a S�PLAlf L REVIEWEL) I OR CODE COMPLIANCE APPROVED it �ci 6 g 4 Ngo H ceD of- crM mg_ OCT 2 5 2016 PL Nmew E 7W CitiGf-T"ukwiIp BUILDING D . BION \ ...... \ .......... \ .. \ NN ....... \ \ \ \ \ \ . \\S.\ 6 TENANT AREA SITE PIAN ECd1.Er I" • 30' Pie 01010E W Wfl0' RECEIVED CITY OF TUKWILA OCT 112016 PERMIT CENTER •) VI \ \ \ • ••.1 Lt.\ • SD -I =odorr.nt. and DW4O.w UosorDocurnanta,CAD13130210226 0VAd0A10ou80.nl.r Waal B"W,* P.rMHTERLIN1 BLDG MOMS! 218v1 Ar.. II?! OI AN eNVAIV moos RM City of Tukwila Allan Ekberg, Mayor Department of Community Development - Jack Pace, Director August 22, 2017 Coast to Coast Concrete Cutting & Demolition Attn: Diane Billedo PO Box 1218 Maple Valley, WA 98038 RE: Request for Refund Building Permit D16-0274 Southcenter West Business Park— 1141 AndOver Park W Dear Ms. Billedo, This letter is in response to your written request for the refund of fees paid for expired building permit D16-0274. The Building Official has reviewed your written request and the determination has been made that there will be no refund made due to the fact that the permit expired on May 27, 2017. Sincerely, 'tzU Bill Rambo Permit Technician File: Permit No. D16-0274 Tukwila City Hall • 6200 Southcenter Boulevard • Tukwila, WA 98188 • 206-433-1800 • Website: TukwilaWA.gov Pro Construction, Inc. dba: Coast to Coast Concrete Cutting & Demolition P.O. Box 1218 Maple Valley, WA 98038 (425) 432-1347 1-877-532-1347 Email: coasttocoastconcrete comcast.net August 8, 2017 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite 100 Tukwila, WA 98188 RE: Permit No. 016-0274 Southcenter West Business Park 1141 Andover Park W Attn: Permit Department RECEIVED AUG 212011 Community Development The job above was not performed due to the client going in a different direction because of power in under floor. We were told we could request a refund. Give me a call if you have any questions (425) 432-1347. Thank you, Diane Billedo Bookkeeper Pro Construction Inc. Dba: Coast to Coast Concrete Cutting & Demolition, Inc. ,./( P i r-eci( S --7 —1 % Request for Refund Approved for full refund ElApproved for % refund of fee(s) Denied (provide explanation) rye 1 / e' /04 4 r Signature/Initials 4/3/2017 City of Tukwila Department of Community Development MARK SANDERS PO BOX 1218 MAPLE VALLEY, WA 98038 RE: Permit No. D16-0274 SOUTHCENTER WEST BUSINESS PARK 1141 ANDOVER PARK W Dear Permit Holder: Allan Ekberg, Mayor Jack Pace, Director In reviewing our current records, the above noted permit has not received a final inspection by the City of Tukwila Building Division. Per the International Building Code, International Mechanical Code, Uniform Plumbing Code and/or the National Electric Code, every permit issued by the Building Division under the provisions of these codes shall expire by limitation and become null and void if the building or work authorized by such permit has not begun within 180 days from the issuance date of such permit, or if the building or work authorized by such permit is suspended or abandoned at any time after the work has begun for a period of 180 days. Your permit will expire on 5/27/2017. Based on the above, you are hereby advised to: 1) Call the City of Tukwila Inspection Request Line at 206-438-9350 to schedule for the next or final inspection. Each . inspection creates a new 180 day period, provided the inspection shows progress. -or- 2) Submit a written request for permit extension to the Permit Center at least seven(7) days before it is due to expire. Address your extension request to the Building Official and state your reason(s) for the need to extend your permit. The Building Code does allow the Building Official to approve one extension of up to 180 days. If it is determined that your extension request is granted, you will be notified by mail. In the event you do not call for an inspection and/or receive an extension prior to 5/27/2017, your permit will become null and void and any further work on the project will require a new permit and associated fees. Thank you for your cooperation in this matter. Sincerely, Rachelle Ripley Permit Technician File No: D16-0274 6300 Southcenter Boulevard Suite #100 • Tukwila, Washington 98188 • Phone 206-431-3670 • Fax 206-431-3665 PERMIT COORD COPY PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: D16-0274 DATE: 10/12/16 PROJECT NAME: SOUTHCENTER WEST BUSINESS PARK SITE ADDRESS: 1141 ANDOVER PARK W X Original Plan Submittal Response to Correction Letter # Revision # before Permit Issued Revision # after Permit Issued DEPARTMENTS • PO PM& 1°1 Building Division Public Works 4'A- io-13 i r� Fire Prevention Structural Planning Division UPermit Coordinator PRELIMINARY REVIEW: Not Applicable n (no approval/review required) REVIEWER'S INITIALS: DATE: 10/13/16 Structural Review Required DATE: APPROVALS OR CORRECTIONS: DUE DATE: 11/10/16 Approved Corrections Required n Approved with Conditions n nDenied (corrections entered in Reviews) (ie: Zoning Issues) Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW 0 Staff Initials: 12/18/2013 COAST TO COAST CONCRETE Home Espanol Contact Safety & Health Claims & Insurance Washington State Department of Labor & Industries Page 1 of 2 Search L&I A-2 Index Help My L&I Workplace Rights Trades & Licensing COAST TO COAST CONCRETE Owner or tradesperson Principals SANDERS, MARK JOSEPH, PRESIDENT SANDERS, JODY LINN, SECRETARY Doing business as COAST TO COAST CONCRETE WA UBI No. 601 760 910 PO BOX 1218 MAPLE VALLEY, WA 98038 425-432-1347 KING County Business type Corporation Governing persons JODY L SANDERS MARK J SANDERS; License Verify the contractor's active registration / license / certification (depending on trade) and any past violations. Construction Contractor License specialties CONCRETE License no. COASTCC011PL Effective — expiration 10/13/1999— 01/10/2017 Active. Meets current requirements. Bond ........_.._... No bond accounts during the previous 6 year period. Insurance Ohio Security Ins Co $1,000,000.00 Policy no. BKS54948294 Received by L&I Effective date 12/30/2015 01/05/2014 Expiration date 01/05/2017 Insurance history Savings (in lieu of bond) $6,000.00 Received by L&I Effective date 01/10/2002 01/08/2002 Release date Impaired date N/A N/A Savings account ID Help us improve https://secure.lni.wa.gov/verify/Detail.aspx?UBI=601760910&LIC=COASTCC011 PL&SAW= 11/28/2016