Loading...
HomeMy WebLinkAboutPermit D16-0277 - CITY OF TUKWILA / MINKLER SHOPS - IMPROVEMENTMINKLER SHOPS 600 MINKLER BLVD D16-0277 Parcel No: Address: Project Name: City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-438-9350 Web site: http://www.TukwilaWA.gov DEVELOPMENT PERMIT 2523049070 Permit Number: D16-0277 600 MINKLER BLVD MINKLER SHOPS Issue Date: 10/31/2016 Permit Expires On: 4/29/2017 Owner: Name: Address: Contact Person: Name: Address: Contractor: Name: Address: License No: Lender: Name: Address: TUKWILA CITY OF 6200 SOUTHCENTER BLVD , TUKWILA, WA, 98188 JEFF HEGLUND 600 MINKLER BLVD , TUKWILA, WA, 98188 AFFIDAVIT - JEFF HEGLUND N/A - LESS THAN $5,000 I II Phone: (206) 571-6312 Phone: Expiration Date: DESCRIPTION OF WORK: REMOVE THE EXISTING GARAGE DOOR AND FILL IN WITH NEW WALL AND SIDING, A LARGER EXIT DOOR, AND TWO WINDOWS FOR THE SECOND STORY OFFICE. THE FLOOR INSIDE WILL BE EXTENDED TO THE EXTERIOR WALL BY 8 FEET FOR THE SECONG STORY OFFICE. THE BUILDING FOOTPRINT WILL NOT BE CHANGES. Project Valuation: $2,000.00 Type of Fire Protection: Sprinklers: NO Fire Alarm: NO Type of Construction: VB Electrical Service Provided by: TUKWILA Fees Collected: $224.66 Occupancy per IBC: B Water District: TUKWILA Sewer District: TUKWILA Current Codes adopted by the City of Tukwila: International Building Code Edition: International Residential Code Edition: International Mechanical Code Edition: Uniform Plumbing Code Edition: International Fuel Gas Code: 2015 2015 2015 2015 2015 National Electrical Code: WA Cities Electrical Code: WAC 296-46B: WA State Energy Code: 2014 2014 2014 2015 Public Works Activities: Channelization/Striping: Curb Cut/Access/Sidewalk: Fire Loop Hydrant: Flood Control Zone: Hauling/Oversize Load: Land Altering: Landscape Irrigation: Sanitary Side Sewer: Sewer Main Extension: Storm Drainage: Street Use: Water Main Extension: Water Meter: Volumes: Cut: 0 Fill: 0 Number: 0 No Permit Center Authorized Signature: /...M.^— Date: (0 I hearby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this development permit and agree to the conditions attached to this permit. Signature: Date: /O/3// /6, Print Nam !!! This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: ***BUILDING PERMIT CONDITIONS*** 2: Work shall be installed in accordance with the approved construction documents, and any changes made during construction that are not in accordance with the approved construction documents shall be resubmitted for approval. 3: All permits, inspection record card and approved construction documents shall be kept at the site of work and shall be open to inspection by the Building Inspector until final inspection approval is granted. 4: All construction shall be done in conformance with the Washington State Building Code and the Washington State Energy Code. 5: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 1700 BUILDING FINAL** 0409 FRAMING 0601 WALL INSULATION 0413 WALL SHEATHING/SHEAR CITY OF TUKWILA Community Development Department Public Works Department Permit Center 6300 Southcenter Blvd, Suite 100 Tukwila, WA 98188 http://wwvv.TukwilaWA.gov Building Permit No. --//6-0 a� 7 Project No. Date Application Accepted: /0 J(a Nof Date Application Expires: (For office use only) CONSTRUCTION PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **Please Print** SITE LOCATION Site Address: 600 Minlder Blvd, Tukwila WA, 98188 King Co Assessor's Tax No.: Suite Number: Tenant Name: Sewer/ Surfacewater Maintenance Crew New Tenant: PROPERTY OWNER Name: Jeff Heglund Name: City of Tukwila City: Tukwila State: WA Zip: 98188 Address: 6200 Southcenter Blvd Email: jeff.heglund@tukwilawa.gov City: Tukwila State: WA Zip: 98188 CONTACT PERSON — person receiving all project communication Name: Jeff Heglund Address: 600 Minkler Blvd City: Tukwila State: WA Zip: 98188 Phone: (206) 571-6312 Fax: Email: jeff.heglund@tukwilawa.gov GENERAL CONTRACTOR INFORMATION Company Name: Address: Company Name: Address: Architect Name: City: State: Zip: Phone: Fax: Phone: Fax: Contr Reg No.: Email: Exp Date: Tukwila Business License No.: H:\ApplicationsTorms-Applications On Line \201 I Applications\Permit Application Revised - 8-9-11.docx Revised: August 2011 bh Floor: ❑ Yes m..No ARCHITECT OF RECORD Name: Address: Company Name: Architect Name: Address: City: State: Zip: Phone: Fax: Email: ENGINEER OF RECORD Name: Address: Company Name: Engineer Name: Address: City: State: Zip: Phone: Fax: Email: LENDER/BOND ISSUED (required for projects $5,000 or greater per RCW 19.27.095) Name: Address: City: State: Zip: Page 1 of 4 BUILDING PERMIT INFORMATION — 206-431-3670 Valuation of Project (contractor's bid price): $ 2,000 Existing Building Valuation: $ Describe the scope of work (please provide detailed information): Remove the existing garage door and fill in with new wall and siding, a larger exit door, and two windows for the second story office. The floor inside will be extended to the exterior wall by 8 feet for the second story office. The building footprint will not be changed. Will there be new rack storage? ❑ Yes m.. No If yes, a separate permit and plan submittal will be required. Provide All Building Areas in Square Footage Below PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact: Handicap:_ Will there be a change in use? ❑ Yes 0 No If "yes", explain: FIRE PROTECTION/HAZARDOUS MATERIALS: 0 Sprinklers 0 Automatic Fire Alarm ® None ❑ Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes No If `yes', attach list of materials and storage locations on a separate 8-1/2" x 11" paper including quantities and Material Safety Data Sheets. SEPTIC SYSTEM 0 On-site Septic System — For on-site septic system, provide 2 copies of a current septic design approved by King County Health Department. H:\Applications\Forms-Applications On Line \2011 Applications\Permit Application Revised - 8.9-11.docx Revised: August 2011 bh Page 2 of 4 Existing Interior Remodel Addition to Existing Structure New Type of Construction per IBC Type of Occupancy per IBC 1st Floor rd Floor 300 I (0D 3rd Floor Floors thru Basement Accessory Structure* Attached Garage Detached Garage Attached Carport Detached Carport Covered Deck Uncovered Deck PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact: Handicap:_ Will there be a change in use? ❑ Yes 0 No If "yes", explain: FIRE PROTECTION/HAZARDOUS MATERIALS: 0 Sprinklers 0 Automatic Fire Alarm ® None ❑ Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes No If `yes', attach list of materials and storage locations on a separate 8-1/2" x 11" paper including quantities and Material Safety Data Sheets. SEPTIC SYSTEM 0 On-site Septic System — For on-site septic system, provide 2 copies of a current septic design approved by King County Health Department. H:\Applications\Forms-Applications On Line \2011 Applications\Permit Application Revised - 8.9-11.docx Revised: August 2011 bh Page 2 of 4 PUBLIC WORKS PERMIT INFORMATION — 206-433-0179 Scope of Work (please provide detailed information): Remove the existing garage door and fill in with new wall and siding, a larger exit door, and two windows for the second story office. The floor inside will be extended to the exterior wall by 8 feet for the second story office. The building footprint will not be changed. Call before you Dig: 811 Please refer to Public Works Bulletin #1 for fees and estimate sheet. Water District VI ...Tukwila ❑ ... Water District #125 ❑ ...Water Availability Provided Sewer District VI ...Tukwila ❑ ...Sewer Use Certificate ❑ .. Highline 1=1 ...Valley View ❑ .. Renton ❑...Sewer Availability Provided ❑ .. Renton ❑ .. Seattle Septic System: ❑ On-site Septic System — For on-site septic system, provide 2 copies of a current septic design approved by King County Health Department. Submitted with Application (mark boxes which apply): ❑ ...Civil Plans (Maximum Paper Size — 22" x 34") ❑ ...Technical Information Report (Storm Drainage) ❑ ...Bond 1=1.. Insurance ❑ .. Easement(s) Proposed Activities (mark boxes that apply): ❑ ...Right-of-way Use - Nonprofit for less than 72 hours ❑ ...Right-of-way Use - No Disturbance ❑ ...Construction/Excavation/Fill - Right-of-way ❑ Non Right-of-way ❑ ❑ ...Total Cut cubic yards ❑ .. Work in Flood Zone ❑ ...Total Fill cubic yards ❑ .. Storm Drainage ❑ .. Geotechnical Report ❑ .. Maintenance Agreement(s) ❑...Traffic Impact Analysis ❑ ...Hold Harmless — (SAO) ❑ ...Hold Harmless — (ROW) ❑ .. Right-of-way Use - Profit for less than 72 hours ❑ .. Right-of-way Use — Potential Disturbance ❑ ...Sanitary Side Sewer ❑ ...Cap or Remove Utilities ❑ ...Frontage Improvements ❑ ...Traffic Control ❑ ...Backflow Prevention - Fire Protection Irrigation Domestic Water ❑ .. Abandon Septic Tank ❑ .. Curb Cut ❑ .. Pavement Cut ❑ .. Looped Fire Line 11 11 ❑ .. Grease Interceptor ❑ .. Channelization ❑ .. Trench Excavation ❑ .. Utility Undergrounding ❑ ...Permanent Water Meter Size... If WO # ❑ ...Temporary Water Meter Size .. >9 WO # ❑ ...Water Only Meter Size WO # ❑ ...Deduct Water Meter Size ❑ ...Sewer Main Extension Public ❑ Private ❑ ❑ ...Water Main Extension Public ❑ Private ❑ FINANCE INFORMATION Fire Line Size at Property Line Number of Public Fire Hydrant(s) ❑ ...Water ❑ ...Sewer ❑ ...Sewage Treatment Monthly Service Billing to: Name: Day Telephone: Mailing Address: Water Meter Refund/Billing: Name: Mailing Address: City State Zip Day Telephone: City State Zip H:WpplicationsWorms-Applications On Line \2011 Applications\Permit Application Revised - 8-9-I l.does Revised: August 2011 bh Page 3 of 4 PERMIT APPLICATION NOTES — Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OW .J' A THORIZED AGENT: Signature: Date: 10/12/2016 Print Name: eff gland Day Telephone: (206) 571-6312 Mailing Address: 600 Minkler Blvd H:\Applications\Forms-Applications On Line \2011 Applications\Permit Application Revised - 8.9.11.docx Revised: August 2011 bh Tukwila WA 98188 City State Zip Page 4 of 4 Cash Register Receipt City of Tukwila DESCRIPTIONS ACCOUNT QUANTITY PermitTRAK PAID $224.66 D16-0277 Address: 600 MINKLER BLVD Apn: 2523049070 $224.66 DEVELOPMENT $218.18 PERMIT FEE R000.322.100.00.00 0.00 $129.50 PLAN CHECK FEE R000.345.830.00.00 0.00 $84.18 WASHINGTON STATE SURCHARGE B640.237.114 0.00 $4.50 TECHNOLOGY FEE $6.48 TECHNOLOGY FEE TOTAL FEES PAID BY RECEIPT: R9626 R000.322.900.04.00 0.00 $6.48 $224.66 Date Paid: Wednesday, October 12, 2016 Paid By: CITY OF TUKWILA Pay Method: CITY ACCOUNT 412.01.538.380.41.00 Printed: Wednesday, October 12, 2016 10:40 AM 1 of 1 CRWSYSTEMS INSPECTION RECORD Retain a copy with permit Di& - 027 7 PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project: YYI) J L Slim Tie of Inspection: 6.» t_DiAf WA L Address:` 6a,) in l itgQ Date Called: Special Instructions: Date Want d:m. J 6/07 Am Pm. Reques Phone No: Z96 -S-7 i-631 2 - Approved per applicable codes. O Corrections required prior to approval. COMMENTS: Inspector: ithsi Date: ; io '7 REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit PERMIT PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project: M) N eavW SWOPS Type of Inspection: It1ALL A uMi1 .J Address: Gcch ill IA/".i. 13(--V Date Called: Special Instructions: . Date Wanted j i Z/ � / co a.m. p.m. Requester: Cr.r. Phone No: 206 -s--7/ -e3i2 Approved per applicable codes. Corrections required prior to approval. COMMENTS: Inspector:/ Date: l a ke REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. IBMINSPECTION RECORD Retain a copy with permit INSP =. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project: 1/ I AJ'KC SI -1 IPS Typnspection: t—e-4Wli s - Ad ress: Date Called: Special Instructions: Date Wanted: I2 (/� a m: �rrrrnn Requester: Phone No: .2c6-5-7/-63/2 Approved per applicable codes. Corrections required prior to approval. COMMENTS: Inspector: Avs..1 Date: t iY REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 '1)16 -Gi?i S1 - Project: �'Y I AJY.W ' 0 -PS Type of Inspection: WAIL 51#an41.0G Slur Address: Date Called: Special Instructions: Date Wanted:)/�`<74 CP Requestse Phone No: 2o6 --S"71 -G3aZ al Approved per applicable codes. LJ Corrections required prior to approval. COMMENTS: Inspector: r/��dnil Dater 1�/6_ i/ REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 b'& '2?? Project: I Vl i Ai g L� 5)1O Type of Inspection: 1/AW S146t174�J� Si -WA -2. Address: 600 iv) hvkLet (L VI Date Called: Special Instructions: Date Wanted: 11 Zai )6 a.m. p.m. Requester: Phone No: 0 Approved per applicable codes. LJ Corrections required prior to approval. COMMENTS: CA-7•166-1064)/ki (2C- Inspector: 2e Inspector: Date: 29 /G REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 DiG-- Oa? i Project: M I A11(.L is S %-PS Type o spection: /litGN1 xi Address: 6 2J, LE= ' &V Date Called: Special Instructions: Date Wante : iI 2tq l6 �.c�, 'gin Requester Phone No: 206-c7I -631 2 Approved per applicable codes. LJ Corrections required prior to approval. COMMENTS: CA-Aitette-b Afer- acity inspector:/ Date: 2g, /,� REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. ME COPY PermEtcKo. TA0-02.1'1 Plan roview Fpproval is subject to errors and omissions. Approval of construction documents does not authorize the violation of any adopted code or ordinance. Receipt of approved Field Copy and conditions is acknowledg3d: By: l� Date: City of Tukila BUILD ING DIVISIC3! N MINKLER !AT/D. lr r i ---REVISIONS No changes shall be made to the scope of work without prior approval of Tukvr4a Building Division. if���T2. i-; .au;s�L is will require a new plan submittal •PnJ may ina;ude additional plan review fees 3 SCOPE OF WORK SCOPE OF WORK MINKLER SHOPS, CITY OF TUKWA 600 MINKLER BLVD 98188 (5��,..., �LitlllT —®"Mechanical .Qr E+cctrlcal .pePiumbing Las Piping of Tukwila EU'•Lr : ` ; DIVISION DO NOT SCALE SCOPE OF WORK PROJECT: * REMOVE THE EXISTING GARAGE DOOR AND FILL IN WITH NEW WALL AND SIDING WITH A LARGER EXIT DOOR. * THE FLOOR INSIDE WILL BE EXTENDED TO THE EXTERIOR WALL BY 8 FEET FOR THE SECOND STORY OFFICE. * BUILDING FOOTPRINT SHALL NOT CHANGE. * DEMO ONE INTERIOR WALL BELOW AND ONE ABOVE TO ENLARGE THE TWO OFFICES. * ELECTRICAL OUTLETS AND LIGHTING SHALL BE ALTERED FOR THE NEW OFFICE CONFIGURATIONS. CURRENT CODES 2015 2015 '2015 2015 2015 2015 2015 2014 2015 \ 2015 \, 2009 IBC INTERNATIONAL BUILDING CODE (Third edition) IRC INTERNATIONAL RESIDENTIAL CODE (Third edition) IEBC INTERNATIONAL EXISTING BUILDING CODE IMC INTERNATIONAL MECHANICAL CODE IFC INTERNATIONAL FIRE CODE IFGC INTERNATIONAL FUEL GAS CODE UPC UNIFORM PLUMBING CODE NEC NATIONAL ELECTRICAL CODE IPMC INTERNATIONAL PROPERTY MAINTENANCE CODE WSEC WASHINGTON STATE ENERGY CODE ICC/ANSI ACCESSIBILITY CODES l(0-0 RECEIVED CITY OF TUKWILA OCT 12 2016 PERMIT CENTER Name MINKLER SHOPS, CITY OF TUKWILA Site Address 600 MINKLER BLVD 98188 Legal: POR OF W 1/2 OF SW 1/4 DAF: BEG 267.52 FT E 7O. E ,Ik�NtD1-O q S881232E254FTITHN01-4728E/2; TH N 8E51 COMPLIA 461,:4 FT TO SWLY MGN OF CHRISTENSEN RD; f:1(�i C ovED TH ALG SD SWLY MGN S 44-38-35 E 173.59 FT; TH C NTG ALG SD SWLY MGN S 66-44-35 E 12.83 FT; TH S 016 88- 7 12 2 E 356 T OWLY MGN SD RD; TH ALG SD M?N S 01-32-25 W 155.90 FT; TH CONTG ALG SD M N S 24-22-35 W 164.42 FT; TH CONTG ALG rtiik§D MCN S 40-34-25 W 189.39 FT; TH CONTG ALG vISR MGN S 47-13-25 W 184.18 FT TH N 88-12-32 W 28.699 FT TH N 01-47-28 E 667.59 FT; TH N 88-12-32 W 350 FT; TH N 01-47-28 E 21 FT TO BEG INDEX OF PAGES OCT 2 5 SHEET 1 SITE PLAN 2 FLOOR P 3. FRAMING N City of Tui D T LS)ING D PAGE: 1 SITE PLAN SCALE: As Noted DATE: Thursday, October 06, 2016 DRAWN BY: ALLEN JOHANNESSEN PROJECT AND LOCATION: 600 MINKLER BLVD Tukwila 98188 MINKLER SHOP PHONE: 206-433-1860 FAX: EMAIL: Jeff.Heglund@TukwilaWA.gov City of Tukwila 6300 Southcenter Blvd. Ste 100 Tukwila 98188 PHONE: 206-433-7163 FAX: al.johannessen@tukwilawa.gov ELECTRICAL LEGEND (FIRST FLOOR) ELECTRICAL COUNT SYMBOL NOTES Fluorescent light 1 x 4 2 Field verify location and fixture type. Outlet 5 d Connect to existing and field verify desired location EXISTING GLUE LAM TO REMAIN DEMO EXISTING WALL (SECOND FLOOR) DEMO EXISTING WALL BELOW AND ELECTRICAL OUTLETS 0 n / 31 / 3' 7 .7 DEMO EXISTING GARAGE DOOR NEW 36" X 84" 11/11 Ve r rl EXTERIOR METAL DOOR tfitlr"dW NEW WALL (SEE DETAILS) - 14' -0" 20'-1" 3'-0" C \, 3'-0" 4" N f'i (d / MAIN FLOOR OFFICE WALL FRAMING AND DEMO (SCALE 1/4" = 1') 2X4 WALL ABOVE AND BELOW FLOOR FRAMING ELECTRICAL NOTE: SECOND FLOOR USE EXISTING CEILING LIGHTING PROVIDE OUTLETS AS NEEDED, FIELD VERIFY. 3"X1/2" WEDGE ANCHORS TYP. 8 PLACES LU210 JOIST HANGERS TYP - --- -- �---D- ----�J--------r-- ,01 2X10 HF #2 16' O.C. 2X8 WALL ABOVE FLOOR FRAMING L. 4'-0" x 4'-6" 4 -0" x 4 -6" 2'-0" 4'-0" j, 2'-0" j, 4'-0" di, 2'-0" 2- INSULATED VINYL FRAME U-30 WINDOWS 14'-0" SECOND FLOOR OFFICE R5" AWED FOR FLOOR FRAMVIIF&6MPLIANCE (SCALE 1/4" = 1') APPROVED OCT 2 5 2016 City of Tukwila BUILDING DIVISION 2X4 WALL ABOVE AND BELOW FLOOR FRAMING RECEIVED ITY OF TUKWILA OCT 12 2016 PERMIT CENTER PAGE: 2 FLOOR PLAN SCALE: 1/4" = 1'-0" DATE: Thursday, October 06, 2016 DRAWN BY: ALLEN JOHANNESSEN PROJECT -AND -LOCATION: MINKLER SHOP 600 MINKLER BLVD PHONE: 206-433-1860 Tukwila FAX: 98188 EMAIL: Jeff.Heglund@TukwilaWA.gov City of Tukwila 6300 Southcenter Blvd. Ste 100 PHONE: 206-433-7163 Tukwila FAX: 98188 al.johannessen@tukwilawa.gov f PAGE: 3 EXISTING CONCRETE TILT UP NO CHANGE CAULK AND SEAL AROUND WALL INFILL EXTERIOR HARDY BOARD SIDING VAPOR BARRIER 7/16" OSB SHEATHING NAIL 6" EDGE, 12" FILED 2X8 HF WOOD STUD R-21 INSULATION 5/8" GWB TAPE AND FINISH 2X4 WALL FULL HEIGHT VAPOR BARRIER R-15 INSULATION EXTEND TO ROOF DECK TOP OF DOOR OPENING (E) BLOCKING BETWEEN HEADER ANCHOR BOLTS NEW WINDOW SEE PLAN WALL BEYOND TOE NAIL W/16d @ 3' O.C. TO WALL TOP PLATE -•—• DEMO WALL 3/4 PLYWOOD GLUE & NAIL 6" EDGE 8" FIELD • MATCH EXISTING FLOOR FINISHES (E) GLUE LAM \ SIMPSON LU210 2X10 HF #2 JOIST 5/8" GWB CEILING NEW EXTERIOR DOOR (SEE PLAN) WEATHER SEAL AND THRESHOLD USE EXISTING CLOSER AND HARDWARE EXISTING FLOOR co � 4 Z1 f, I WALL CROSS SECTION 3-A (SCALE 1/4" = 1') NOTE: ALL FRAMING AND CONSTRUCTION WORK INCLUDING MATERIALS AND FASTNERS SHALL FOLLOW CURRENT INDUSTRY STANDARDS AND PRESCRIPTIVE BUILDING CODES. CONSULT WITH DESIGNER OR THE BUILDING OFFICIAL IF UNUSUAL THINGS ARE FOUND DURING CONSTRUCTION REQUIRING CHANGES AND PROVIDE REVISIONS TO THE BUILDING DEPARTMENT FOR REVIEW. 2X8 HF @ 24" O.C. TYP. D a 4 v EXISTING TILT UP CONC. 3" X 3/8" WEDGE ANCHORS @ 24" O.C. TYP. 6" FROM ENDS OF PT PLATE PRESSURE TREATED 2X6 * FIRST CLEAN SURFACE OF CONCRETE. * CAULK ALONG PRESSURE TREATED 2X MUD SILL. * APPL'Y TWO SILICONE CAULK BEADS 1-1/2" APART ON CONCRETE. * PRESS 2X3 BROWN FLASHING (3" VERTICAL) OVER CAULK, NAIL TO FRAMING UNDER SHEATHING. * ONE CAULK BEAD OVER BOTTOM FLASHING (2"). * PRESS 1-1/2" X 1-1/2" BROWN DRIP EDGE OVER CAULK, NAIL OVER EXTERIOR OF SHEATHING. * BE SURE TO HOLD SHEATHING 1" UP FROM FLOOR. * START HARDY BOARD SIDING 1" UP FROM FLOOR. WALL DETAILS ----3-B_ RE 1IED FOR CODE COMPLIANCE APPROVED OCT 2 5 2016 CI (SCALE 1/2" = 1') City of Tukwila BUILDING DIVISIOIPERMi IT CENTER RECEIVED OF TUKWILA OCT 12 2016 FRAMING DETAILS SCALE: 1/4" = 1'-0" DATE: Friday, October 07, 2016 DRAWN BY: ALLEN JOHANNESSEN PROJECT AND LOCATION: 600 MINKLER BLVD Tukwila 98188 MINKLER SHOP PHONE: 206-433-1860 FAX: EMAIL: Jeff.Heglund@TukwilaWA.gov City of Tukwila 6300 Southcenter Blvd. Ste 100 Tukwila 98188 PHONE: 206-433-7163 FAX: al .johannessen@tukwilawa.gov vERMIT COORD COPY. PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: D16-0277 PROJECT NAME: MINKLER SHOPS SITE ADDRESS: 600 MINKLER BLVD X Original Plan Submittal Response to Correction Letter # DATE: 10/12/16 Revision # before Permit Issued Revision # after Permit Issued DEPARTMENTS: iwo tbt\` Building Division Pub is Wor s M\ A//4b 1fr t /if'Fire Prevention m Planning Division Structural ❑ Permit Coordinator m PRELIMINARY REVIEW: Not Applicable Ti (no approval/review required) DATE: 10/13/16 Structural Review Required REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: Approved n DUE DATE: 11/10/16 Approved with Conditions ❑ Corrections Required Denied (corrections entered in Reviews) (ie: Zoning Issues) Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg D Fire 0 Ping 0 PW 0 Staff Initials: 12/18/2013 CITY OF TUKWILA Department of Community Development 6300 Southcenter Boulevard, Tukwila, WA 98188 Telephone: (206) 431-3670 FAX (206) 431-3665 E-mail: tukplan(aci.tukwi]a.wa.us Permit Center/Building Division 206 431-3670 Public Works Department 206 433-0179 Planning Division 206 431-367o AFFIDAVIT IN LIEU OF CONTRACTOR REGISTRATION STATE OF WASHINGTON) ) ss. COUNTY OF KING ) [pleal print name] , states as follows: PERMIT NO: 1. I have made application for a permit from the City of Tukwila, Washington. 2. I understand that state law requires that all building construction contractors be registered with the State of Washington. The exceptions to this requirement are stated under Section 18.27.090 of the Revised Code of Washington, a copy of which is printed on the reverse side of this Affidavit. I have read or am familiar with RCW 18.27.090. 3. I understand that prior to issuance of a permit for work which is to be done by any contractor, the City of Tukwila must verify either that the contractor is registered by the State of Washington, or that one of the exemptions stated under RCW 18.27.090 applies. 4. In order to provide verification to the City of Tukwila of my compliance with this requirement, I hereby attest that after reading the exemptions from the registration requirement of RCW 18.27.090, I consider the work authorized under this permit to be exempt under number 13, and will therefore not be performed by a registered contractor. 5. I understand that the licensing provision of RCW 19.28.161 through 19.28.271 shall not apply to persons making electrical installations on their own property or to regularly employed employees working on the premises of their employer. The proposed electrical work is not for the construction of a new building for rent, sale or lease. I understand that I may be waiving certain rights that I might otherwise have under state law in any decision to engage an unregistered contractor to perform construction work. LAURIE A. WERLE NOTARY PUBLIC STATE OF WASHINGTON COMMISSION EXPIRES MAY 29, 2018 Signed and sworn to before me this 3I 51 -day of OC>1get-- ,20/6. ROTARY PUBLIC in an for the State of Washington Residing at 1//19- , County Name as commissioned: A20,1 Alabde My commission expires:OS( c1/7Y 18.27.090 Exemptions. The registration provisions of this chapter do not apply to: 1. An authorized representative of the United States government, the state of Washington, or any incorporated city, town, county, township, irrigation district, reclamation district, or other municipal or political corporation or subdivision of this state; 2. Officers of a court when they are acting within the scope of their office; 3. Public utilities operating under the regulations of the utilities and transportation commission in construction, maintenance, or development work incidental to their own business; 4. Any construction, repair, or operation incidental to the discovering or producing of petroleum or gas, or the drilling, testing, abandoning, or other operation of any petroleum or gas well or any surface or underground mine or mineral deposit when performed by an owner or lessee; 5. The sale of any finished products, materials, or articles of merchandise that are not fabricated into and do not become a part of a structure under the common law of fixtures; 6. Any construction, alteration, improvement, or repair of personal property performed by the registered or legal owner, or by a mobile/manufactured home retail dealer or manufacturer licensed under chapter 46.70 RCW who shall warranty service and repairs under chapter 46.70 RCW; 7. Any construction, alteration, improvement, or repair carried on within the limits and boundaries of any site or reservation under the legal jurisdiction of the federal government; 8. Any person who only furnished materials, supplies, or equipment without fabricating them into, or consuming them in the performance of, the work of the contractor; 9. Any work or operation on one undertaking or project by one or more contracts, the aggregate contract price of which for labor and materials and all other items is less than five hundred dollars, such work or operations being considered as of a casual, minor, or inconsequential nature. The exemption prescribed in this subsection does not apply in any instance wherein the work or construction is only a part of a larger or major operation, whether undertaken by the same or a different contractor, or in which a division of the operation is made into contracts of amounts less than five hundred dollars for the purpose of evasion of this chapter or otherwise. The exemption prescribed in this subsection does not apply to a person who advertises or puts out any sign or card or other device which might indicate to the public that he or she is a contractor, or that he or she is qualified to engage in the business of contractor; 10. Any construction or operation incidental to the construction and repair of irrigation and drainage ditches of regularly constituted irrigation districts or reclamation districts; or to farming, dairying, agriculture, viticulture, horticulture, or stock or poultry raising; or to clearing or other work upon land in rural districts for fire prevention purposes; except when any of the above work is performed by a registered contractor; 11. An owner* who contracts for a project with a registered contractor, except that this exemption shall not deprive the owner of the protections of this chapter against registered and unregistered contractors. The exemption prescribed in this subsection does not apply to a person who performs the activities of a contractor for the purpose of leasing or selling improved property he or she has owned for less than twelve months; 12.* Any person working on his or her own property, whether occupied by him or her or not, and any person working on his or her personal residence, whether owned by him or her or not but this exemption shall not apply to any person who performs the activities of a contractor on his or her own property for the purpose of selling, demolishing, or leasing the property; 13. An owner* who performs maintenance, repair, and alteration work in or upon his or her own properties, or who uses his or her own employees to do such work; 14. A licensed architect or civil or professional engineer acting solely in his or her professional capacity, an electrician certified under the laws of the state of Washington, or a plumber certified under the laws of the state of Washington or licensed by a political subdivision of the state of Washington while operating within the boundaries of such political subdivision. The exemption provided in this subsection is applicable only when the person certified is operating within the scope of his or her certification; 15. Any person who engages in the activities herein regulated as an employee of a registered contractor with wages as his or her sole compensation or as an employee with wages as his or her sole compensation; 16. Contractors on highway projects who have been prequalified as required by RCW 47.28.070, with the department of transportation to perform highway construction, reconstruction, or maintenance work; 17. A mobile/manufactured home dealer or manufacturer who subcontracts the installation, set-up, or repair work to actively registered contractors. This exemption only applies to the installation, set-up, or repair of the mobile/manufactured homes that were manufactured or sold by the mobile/manufactured home dealer or manufacturer; 18. An entity who holds a valid electrical contractor's license under chapter 19.28 RCW that employs a certified journeyman electrician, a certified residential specialty electrician, or an electrical trainee meeting the requirements of chapter 19.28 RCW to perform plumbing work that is incidentally, directly, and immediately appropriate, to the like -fin -kind replacement of a household appliance or other small household utilization equipment that requires limited electric power and limited waste and/or water connections. An electrical trainee must be supervised by a certified electrician while performing plumbing work. " Per Washington State Department of Labor and Industries lessee has been interpreted to be equivalent to owner for purposes of exemptions.