Loading...
HomeMy WebLinkAboutPermit D16-0288 - MOTION INDUSTRIES - STORAGE RACKINGMOTION INDUSTRIES 18436 CASCADE AVE S 160 D16-0288 Parcel No: Address: City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-438-9350 Web site: http://www.TukwilaWA.gov DEVELOPMENT PERMIT 7888900030 18436 CASCADE AVE S 160 Project Name: MOTION INDUSTRIES Permit Number: D16-0288 Issue Date: 11/22/2016 Permit Expires On: 5/21/2017 Owner: Name: Address: Contact Person: Name: Address: Contractor: Name: Address: License No: Lender: Name: Address: CPF KENT VALLEY LLC 100 WILSHIRE BLVD #700 , SANTA MONICA, WA, 90401 NICK HOFFMAN 1100 SW 7TH ST, RENTON, WA, 98057 NORTH WEST HANDLING SYS INC 1100 SW 7TH ST, RENTON, WA, 98055 NORTHWH275JF MOTION INDUSTRIES 18436 CASCADE AVE S , TUKWILA, WA, 98188 Phone: (425) 902-7222 Phone: (206) 255-0500 Expiration Date: 10/9/2017 DESCRIPTION OF WORK: RACKING Project Valuation: $47,800.00 Type of Fire Protection: Sprinklers: YES Fire Alarm: YES Type of Construction: VB Electrical Service Provided by: TUKWILA Fees Collected: $1,623.42 Occupancy per IBC: B Water District: TUKWILA Sewer District: TUKWILA Current Codes adopted by the City of Tukwila: International Building Code Edition: International Residential Code Edition: International Mechanical Code Edition: Uniform Plumbing Code Edition: International Fuel Gas Code: 2015 2015 2015 2015 2015 National Electrical Code: WA Cities Electrical Code: WAC 296-46B: WA State Energy Code: 2014 2014 2014 2015 Public Works Activities: Channelization/Striping: Curb Cut/Access/Sidewalk: Fire Loop Hydrant: Flood Control Zone: Hauling/Oversize Load: Land Altering: Landscape Irrigation: Sanitary Side Sewer: Sewer Main Extension: Storm Drainage: Street Use: Water Main Extension: Water Meter: Volumes: Cut: 0 Fill: 0 Number: 0 No Permit Center Authorized Signature: US- Date: L I %6 I hearby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this development permit and agree to, conditions attached to this permit. Signature: Print Name: ,f/•cK arl Date: // Z2//� This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: ***BUILDING PERMIT CONDITIONS*** 2: Work shall be installed in accordance with the approved construction documents, and any changes made during construction that are not in accordance with the approved construction documents shall be resubmitted for approval. 3: All permits, inspection record card and approved construction documents shall be kept at the site of work and shall be open to inspection by the Building Inspector until final inspection approval is granted. 4: When special inspection is required, either the owner or the zegistered design professional in responsible charge, shall employ a special inspection agency and notify the Building Official of the appointment prior to the first building inspection. The special inspector shall furnish inspection reports to the Building Official in a timely manner. 5: A final report documenting required special inspections and correction of any discrepancies noted in the inspections shall be submitted to the Building Official. The final inspection report shall be prepared by the approved special inspection agency and shall be submitted to the Building Official prior to and as a condition of final inspection approval. 6: All construction shall be done in conformance with the Washington State Building Code and the Washington State Energy Code. 7: All rack storage requires a separate permit issued through the City of Tukwila Permit Center. Rack storage over 8 -feet in height shall be anchored or braced to prevent overturning or displacement during seismic events. The design and calculations for the anchorage or bracing shall be prepared by a registered professional engineer licensed in the State of Washington. Periodic special inspection is required during anchorage of storage racks 8 feet or greater in height. 8: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center. 9: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 12: The total number of fire extinguishers required for an ordinary hazard occupancy with Class A fire hazards is calculated at one extinguisher for each 1,500 sq. ft. of area. The extinguisher(s) should be of the "AII Purpose" (3A, 40B:C) dry chemical type. Travel distance to any fire extinguisher must be 75' or less. (IFC 906.3) (NFPA 10, 5.4) 10: Portable fire extinguishers, not housed in cabinets, shall be installed on the hangers or brackets supplied. Hangers or brackets shall be securely anchored to the mounting surface in accordance with the manufacturer's installation instructions. Portable fire extinguishers having a gross weight not exceeding 40 pounds (18 kg) shall be installed so that its top is not more than 5 feet (1524 mm) above the floor. Hand- held portable fire extinguishers having a gross weight exceeding 40 pounds (18 kg) shall be installed so that its top is not more than 3.5 feet (1067 mm) above the floor. The clearance between the floor and the bottom of the installed hand-held extinguishers shall not be less than 4 inches (102 mm). (IFC 906.7 and IFC 906.9) 11: Extinguishers shall be located in conspicuous locations where they will be readily accessible and immediately available for use. These locations shall be along normal paths of travel, unless the fire code official determines that the hazard posed indicates the need for placement away from normal paths of travel. (IFC 906.5) 13: Maintain fire extinguisher coverage throughout. 16: Maintain fire alarm system audible/visual notification. Addition/relocation of walls or partitions may require relocation and/or addition of audible/visual notification devices. (City Ordinance #2437) 15: AII new fire alarm systems or modifications to existing systems shall have the written approval of The Tukwila Fire Prevention Bureau. No work shall commence until a fire department permit has been obtained. (City Ordinance #2437) (IFC 901.2) 17: Clearance between ignition sources, such as light fixtures, heaters and flame -producing devices, and combustible materials shall be maintained in an approved manner. (IFC 305.1) 18: Where storage height exceeds 15 feet and ceiling sprinklers only are installed, fire protection by one of the following methods is required for steel building columns located within racks: (a) one-hour fire proofing, (b) sidewall sprinkler at the 15 foot elevation of the column, (c) ceiling sprinkler density minimums as determined by the Tukwila Fire Prevention Bureau. (NFPA 13-16.1.4) 19: Storage shall be maintained 2 feet or more below the ceiling in nonsprinklered areas of buildings or a minimum of 18 inches below sprinkler head deflectors in sprinklered areas of buildings. (IFC 315.3.1) 20: Flue spaces shall be provided in accordance with International Fire Code Table 3208.3. Required flue spaces shall be maintained. 14: Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (City Ordinances #2436 and #2437) 21: Any overlooked hazardous condition and/or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. 22: These plans were reviewed by Inspector 511. If you have any questions, please call Tukwila Fire Prevention Bureau at (206)575-4407. PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 1700 BUILDING FINAL** 1400 FIRE FINAL 4046 SI-EPDXY/EXP CONC CITY OF TUK► ,A Community Development Department Public Works Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.TukwilaWA.gov Building Peri lit No. Project No. Date Application Accepted: O Date Application Expires: I l' (For office use on y, CONSTRUCTION PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the nail or by fax. **Please Print** SITE LOCATION ?-88890:030 ea ,,--_/ //�� C King Co Assessor's Tax No.: '78Q g ?ffle�30 Site Address: /N36 CSS -a-0 & /IVPs $04 Suite Number: /60 Floor: r�%v not Tenant Name: ,A10 O +(0r7 vSTi J Pry New Tenant: Yes ❑ ..No ((cork, (4 A 6781A PROPERTY OWNER Name: a' i hen4- Valley , Lt _ Address: 300 pc564v-te 5 &Jay Scw 4'30t City: vim,7 fn aii...,„r State: w A Zip: 'f 01 CONTACT PERSON - person receiving all project communication Name: /1/6 k Af.� t ti y Address: ,i/ 5fiit)J7 im 5. City: gjeit/vn State: toh Zip:cgoS3- Phone: (t/ZS) qoz.-?zzz Fax: (y.25 -22,2,g rG el. y6 Email: m P (✓(C 1f e A (,c) f S • C00'1 GENERAL CONTRACTOR INFORMATION Company Name: NOr11, )eG (,1a._ ji ss OW (1 rlv Address: /100 .561)9,1.- City: Row-bn State: () A Zip: 9 s, - Phone: (,,a,-.) 2s -oSa? Fax: (car) zz2 - b ?e( Contr Reg No.:Ivo_ Ker_ Ho. Hzts4p Date: /Z(31 J/b Tukwila Business License No.: /5v5 0qct 4oy.- H:\Applications\Forms-Applications On Line \2011 Applications\Perntit Application Rcviscd - 8-9-11.docx Rcviscd: August 2011 bh ARCHITECT OF RECORD Company Name:, ' j pe5dyh 1 67ee/ Company Name: .601 20.�, ((Sa l 1� lm to '(,,./' . / �1 Architect Name: Phone:: 4e/8) .,2 _ 3910 Fax: Address: 3y 3 W Ga t` 0a,,,,,,A P y 56 City: ee`/ , e., State:/u4 Zip: 9 v Phone(gz) G`lf 08� Fax: /,� Email:`` N/4 ENGINEER OF RECORD Company Name:, ' j pe5dyh 1 67ee/ Engineer Name:Com./Mk G an/OM Address: e//.z 42 e oa war s' 20'1 City: je,z a (e..,. State: e 4` Zip: *WI/ ( y Phone:: 4e/8) .,2 _ 3910 Fax: Email: 1' (4 D65 1 0A) y.01r.M tit .601/4 LENDER/BOND ISSUED (required for projects $5,000 or greater per RCW 19.27.095) Name: / I� 040'I_Gitls4i-eS-'5iITAdeot Address ! f/(../T jam City: State: [, Zip: Page 1 of 4 BUILDING PERMIT INFORMATI( 206-431-3670 Valuation of Project (contractor's bid price): $ if 7 j ZOO Existing Building Valuation: $ Describe the scope of work (please provide detailed information): „fin 5-1a Hwy s of Ail AA &,tk 1 a /0/ 41-y S o bcv e/e>lz6eri 5k/1 $ePi a / tcheeC drawn 5 a 5 ea/c. (ons (41.4 ecvfa-lions .4R Will there be new rack storage? 1511. Yes ❑.. No If yes, a separate permit and plan submittal will be required. Provide All Building Areas in Square Footage Below PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact: Handicap: Will there be a change in use? ❑ Yes 0 No If "yes", explain: FIRE PROTECTION/HAZARDOUS MATERIALS: 71, Sprinklers Automatic Fire Alarm D None ❑ Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes No If `yes', attach list of materials and storage locations on a separate 8-1/2"x 11" paper including quantities and Material Saf-ty lata Sheets. SEPTEPT~WE'NM 0 On-site Septic S De — For on ic.system, provide 2 copies of a current septic design approved by King County Health H:\Applications\Forms-Applications On Line \2011 Applications\Pcrmit Application Rcviscd - 8-9-1 I.docx Revised: August 2011 bh Page 2 of 4 Existing Interior Remodel Addition to Existing Structure New Type of Construction per IBC Type of Occupancy per IBC 151 Floor .Z 11 5-Y I 2, /46 s •7 F%//et Ra/ v V fI, �✓ rd Floor .rte Shaw,. 3rd Floor ---- Floors thru Floors Basement Accessory Structure* Attached Garage .------ Detached Garage Attached Carport Detached Carport Covered Deck 1 ---- Uncovered Deck PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact: Handicap: Will there be a change in use? ❑ Yes 0 No If "yes", explain: FIRE PROTECTION/HAZARDOUS MATERIALS: 71, Sprinklers Automatic Fire Alarm D None ❑ Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes No If `yes', attach list of materials and storage locations on a separate 8-1/2"x 11" paper including quantities and Material Saf-ty lata Sheets. SEPTEPT~WE'NM 0 On-site Septic S De — For on ic.system, provide 2 copies of a current septic design approved by King County Health H:\Applications\Forms-Applications On Line \2011 Applications\Pcrmit Application Rcviscd - 8-9-1 I.docx Revised: August 2011 bh Page 2 of 4 PUBLIC WORKS PERMIT INF( IATION — 206-433-0179 Scope 1, f Work (please provide detailed information): Water District ❑ ...Tukwila ❑ ...Water Availability Provided Call before you Dig: 811 Please refer to Public Works Bulletin #1 for fees and estimate sheet. Sewer District ❑ ...Tukwila 0 ...Sewer Use Certificate Septic System: ❑ On-site Septic System — For on-site septic sys em, provide 2 copies of a current septic design appr ed by King County Health Department. ...Water District #125 0 .. Highline ❑ ... Va ey View ❑ .. Renton ❑ ... Sewe vkvailability Provided 0 .. Renton ❑ .. Sea e Submitted with Application (mark boxes which applv): ❑ ...Civil Plans (Maximum Paper Size — 22" x 34") ❑ ...Technical Information Report (Storm Drainage) 0 ...Bond 0 .. Insurance ❑ .. Easement'( Proposed Activities (mark boxes that apply): ❑ ...Right-of-way Use - Nonprofit for less than 72 hours 0 ...Right-of-way Use - No Disturbance 0 ...Construction/Excavation/Fill - Right-of-way 0 Non Right-of-way ❑ 0 ...Total Cut ❑ ...Total Fill cubic yards cubic yards ❑ ...Sanitary Side Sewer ❑ ...Cap or Remove Utilities 0 ...Frontage Improvements ❑ ...Traffic Control 0 ...Backflow Prevention - Fire Protection Irrigation Domestic Water 0 .. Geotechnical Report ❑ ...Traffic Impact Analysis ❑ .. Maintenance Agreenpent(s) 0 ...Hold Harmless — (SAO) ❑ ...Hold Harmless — (ROW) ..Right-of-way ase - Profit for less than 72 hours n.. Right-of-wa Use — Potential Disturbance ❑ .. Wor ,'4 Flood Zone ❑ .. Sto rainage ❑ .. Abandon Septic Tank ❑ .. Curb Cut 0 .. Pavement Cut ❑ .. Looped Fire Line ❑ ...Permanent Water Meter Size... WO # ❑ ...Temporary Water Meter Size .. WO ❑ ...Water Only Meter Size W 4 # ❑ ...Deduct Water Meer Size 0 ...Sewer Main Extension Public 0 .'rivate ❑ ❑ ...Water Main Extension Public 0 Private 0 ❑ .. Grease Interceptor ❑ .. Channelization 0 .. Trench Excavation ❑ .. Utility Undergrounding FINANCE INFORMATION Fire Line Size at Property Line 0 ...Water 0 ...Sew Monthly Service Billing to: Name: Mailing Address: r Number of Public Fire Hydrant(s) 0 ...Sewage Treatment Day Telephone: Water Meter Refund/Billing: Name: / Mailing Address: City State Z p Day Telephone: City State Zip H:\Applications\Fomu-Applications On Line \2011 Applications\Pcrmit Application Revised - 8-9-11.docx Revised: August 2011 bh Page 3 of 4 PERMIT APPLICATION NOTES — Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER Signature: Print Name: RIZED AGENT: A e -k m»mav► Mailing Address: 1/00 $cA) Date: /.°7/1/4 Day Telephone: 611 s) 9oz _ �Z2 2- R CIDIVI RCIDIVI 60.4 i'oas"7i H:\Applications\Forms-Applications On Line \2011 Applications\permit Application Rcviscd - 8-9-11.docx Revised: August 2011 bh City State Zip Page 4 of 4 Cash Register Receipt City of Tukwila DESCRIPTIONS I ACCOUNT QUANTITY PermitTRAK PAID $1,623.42 D16-0288 Address: 18436 CASCADE AVE 5 160 Apn: 7888900030 $1,623.42 DEVELOPMENT $1,575.80 PERMIT FEE R000.322.100.00.00 0.00 $952.30 PLAN CHECK FEE R000.345.830.00.00 0.00 $619.00 WASHINGTON STATE SURCHARGE 8640.237.114 0.00 $4.50 TECHNOLOGY FEE $47.62 TECHNOLOGY FEE TOTAL FEES PAID BY RECEIPT: R9711 R000.322.900.04.00 0.00 $47.62 $1,623.42 Date Paid: Friday, October 21, 2016 Paid By: NICHOLAS HOFFMAN Pay Method: CREDIT CARD 021948 Printed: Friday, October 21, 2016 12:58 PM 1 of 1 CIRWSYSTEMS BILE NORTHWEST HANDLING SYSTEMS, I N C. The Material Handling Experts 1100 SW 7th St Renton, WA 98057 (425) 255-0500 ph (425) 228-6946 fax ATTN: BUILDING DEPARTMENT AND FIRE DEPARTMENT RACK INFORMATION SUPPLEMENT SITE ADDRESS: 18436 Cascade Ave South. STE 160. Tukwila, WA. TENANT NAME: Motion Industries DATE: October 21, 2016 APPLICANT: Nick Hoffman / 425.902.7222 In answer to Correction Letter #1 provided for Permit application # D16-0288 Fire Department: Al Metzler. 206.971.8718 REVIEWED FOR CODE COMPLIANCE APPROVED NOV 1 8 2016 City of Tukwila BUILDING DIVISION 1. Commodities stored in racks: Bearings, metal parts, small electric motors, gearboxes and Gearbox components, assorted conveyor and material handling components. Seals, gaskets, hand tools, hydraulic pumps and components. Small items are stored in cardboard boxes with minimal packaging material consisting of plastic/bubble wrap and/or paper packaging. Larger items stored on standard GMA. pallet, 40"W x 48"L. 2. Total Storage Height in selective racking: Top beam at 15' (180"). Maximum pallet height on top level, 4' (48") 3. Sprinkler Density: .39/5600 Density / Discharge 4. Temperature Rating: White Sprinkler head - 212* fahrenheit 5. Special inspection of anchor bolts will be performed by AAR Testing Lab. PO Box 2523 Redmond, WA 98073. 425-881-5812. 6. Vertical members of storage racks are designed and installed so that failure of one vertical member will not cause collapse of more than the bay or bays directly supported by that member. RECEIVED CITY OF TUKWILA CORRECTION - NOV 08 2016 LTR# PERMIT CENTER BY G. OHANIAN RAGiK DEOIdN & ENcINEERINd do. DATE. 10-20-16 SUBJECT 412 WEOT BROADWAY, 61UITE #204 C LENDALE, dA. 91204 TEL:(818)240-3810 FAX:(818)240-3813 SHEET NO. 1 JOB NO.. RD -18720 STRUCTURAL CALCULATIONS OF STORAGE ,�r� n RACKS FOR:. U IeI MOTION IND. 18436 CASCADE AVE SOUTH TUKWILA, WA 98188 PER IBC 2012/2015 SEC. 2209.1 ASCE 7-10 SEC. 15.5.3 RMI/ANSI/MH 16.1:2012 STORAGE RACKS CAPACITY: 2500 # / LEVEL CALCS. 1 THRU 4 DRAWINGS: RD -18720 REVIEWED FOR LODE COMPLIANCE a' APPROVED NOV 18 2016 City of Tukwila BUILDING DIVISION EXPIRES 12-26-17 RECEIVED CITY OF TUKWILA OCT 21 2016 PERMIT CENTER DUe c'245 BY G. OHANIAN RAdK DEOI(4N & ENOINEERINGt do. DATE 10-20-16 SUBJECT 412 WEOT BROADWAY, BUITE #204 LENDALE, dA. 91204 TEL:(818)240-3810 FAX:(818)240-3813 SHEET NO 2 JOB NO.. RD -18720 .00 96" 1 1 { BEAM DESIGN SEISMIC DESIGN _SDS KI v= Rx 1 .4 xW Ix=1.63 Sx =.77 FY= 55 KSI. d LOAD PER BEAM + 25% IMPACT LOAD (2.5Kx.88)+(1.2Kx.25) = 2.5— 1.3K 2 2 BEAMS M= 8 =15""K S R= .46<.77 4 384.1x .E 180 — IBC 2012/2015 SEC. 2209.1 ASCE 7-10 SEC. 15.5.3, RMI/ANSI/MH 16.1:2012 S Ds =0.94 (USGS WEB SITE, "SITE CLASS D") 1=1 NO PUBLIC ACCESS R=6 MOM. CONN. RMI 2.6 AND 2.6.3 R=4 BRACED W=D.L.+ 3 PALLET LOAD LOAD PER COL. = 3x2.5 K =3.8 K 2 ca. P=.2DL+ (3.8Kx0.75)=3.0K W=.2DL+ (3.8PLx0.67)= 2.7 K V LONGIT.NGIT. 30 K V = .46K TRANS. LONGIT. SEISMIC .30K 3.8"K 5 8"K 7.6"K 7.6 "K BY G. OHANIAN RACK DEOI(N & ENGtINEERINC CO. DATE. 10-20-16 SUBJECT 412 WET BROADWAY, PUITE #204 LENDALE, dA. 91204 TEL:(818)240-3810 FAX:(818)240-3813 SHEET NO 3 JOB NO.. RD -18720 COLUMN DESIGN 3" - — x 1I� M t=.070" COMBINED STRESS RATIO Pex= (KL.,x =71.0 ax=1— PCP = .92 Fy=55 KSI Ae=.62 I x=.95 S8=.6 rx=1.2 ry=1.1 f2c=1.8 Db=1.67 Cmx=.85 BASE PLATE ANCH. TENSION = 0 ANCHOR SHEAR — .15 K KL _52x1.2 =52 rx 1.2 KL =14.0_ -36 Y • Mr,=Se.Fy= 35 Qc.P+ Qb.Cmx.M = .53<1 Pr, Mn.ax (2)-1/2"0 ANCHORS PER BASE PL., 3 1/4" EMB. HILTI KWIK BOLT—TZ ESR -1917 SPECIAL INSPECTION IS REQUIRED MOMENT AT BEAM CONNECTION .5x.07x1 x65=2.3 K BEARING CAPACITY OF COL. HOLE 7/16"0 RIVET A = .1 Fy = 79 KSI Pa = .1x79x.4 = 3 K Ma = (2.3Kx4")+(1.1 Kx2") = 11.4"K 3 PIN CONN. CONN. MEND—.O1xWI2= 1.2 K M = 6.7"K SEISMIC M =7.9"K TOTAL 2 Fe= (KLj2= 108 rx 2 F r,=F y(.658 c )=44 KSI Pr,= Fr, .Ae = 28.0 K 5.7 'K Ac=-\/Fy/Fe = 0.71 Nc<1.5 BY G. OHANIAN RAdK DEOI N & EN(INEERIN(4 do. 412 WET BROADWAY, QUITE #204 LENDALE, dA. 91204 TEL:(818)240-3810 FAX:(818)240-3813 DATE. 10-20-16 SUBJECT SHEET NO. 4 JOB NO. RD -18720 OVERTURNING MOT =.46 Kx2 x172"x0.66 =103 "K co.L MR = 3.0Kx44"= 133"K NO UPLIFT LOAD TO DIAGONAL P=.46Kx2 x52 =1.1K COL. 42 FY =55 KSI Ae=.26 rx =.48 L= 52" Pa= 3.1 K CHECK WELDS p°= (1_.01L)L.t.Fa = 4.4K 0= 2.55 = 1.7Kx2 = 3.4K SIDES CHECK SLAB 3000 =3.0 °' 1000 .46 K 3.Ox 144=432 °'' J' 432=21" M= ( �'2 2 x 1000x 2 S= 12x62 / x12=2344 "# \= 72 6 2344 = 33 <1.6 J 2500 =80 72 .46 K 44" N \ O a a I0 • TOP LEVEL LOADING W= 0.2DL+1.3LL=1.5K LOAD PER COL. V= .24 K MOT=.24Kx cox152"=74"K MR = 1.5 Kx44" = 64"K UPLIFT = 77 44 -.23 K BOTH SIDES TYP. 1 5" 1 x -F9 -x r- \ t=.06" 3000 # 6" CONCRETE SLAB 2500 PSI. CONC. 1000 PSF. SOIL INSPECTION RECORD Retain a copy with permit INSPECTION -NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 bi6-G2b6 Project:) /rnoi7c,i / AIWS1 his Typ of Inspection: ISU 11 /AG- tAl/41. . Address: /PRO 04sc4i /kir g Date Called: Special Instructions: /66 Date Wanted: /a 2 7 A A-1-11 a.m. P.m. Requester: /J, CK' Phone No: q2S = 90Z- 7202, Approved per applicable codes. , LJ Corrections required prior to approval. COMMENTS: OK T� Inspector:At) Apti Date:' Z 9 J REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit b' -CZ36 PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 \Kr Project: /*VOA/ bib OSMCS Type of Inspection: 1 LbidLer rAfA ,... Address: /P1136 CASeAbe j o&M u- LeAbi e- ; 5 Date Called: Special Instructions: ) / ® Date Wanted / %i 30 � (o ,4-& � a.m. P.m. Requester: Phone No: 2o6 -5/b -12g0 Approved per applicable codes. RI Corrections required prior to approval. COMMENTS: t. j o&M u- LeAbi e- .fig- 42.6- pr--- »✓ LAB Inspector:A REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. INSPECTION NUMBER INSPECTION RECORD Retain a copy with permit Ib -C 2. PERMIT NUMBERS CITY OF TUKWILA FIRE DEPARTMENT 206-575-4407 Project: 0(16f t00 I0()vsl»i5 Type of Inspection: -1/--- Address: i `` Suite#: J3/- casco k I've S / Contact Person: Special Instructions: Phone No.: KApproved per applicable codes. Corrections required prior to approval. COMMENTS: ,ze-- 01-6- (N/ c c fs (l 6-67--/O,,3 Needs Shift Inspection: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: Inspector: f vl 5.--A, 1rj; Date: /y /i f , b Hrs.: $100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. Billing Address Attn: Company Name: Address: City: State: Zip: Word/Inspection Record Form.Doc 3/14/14 T.F.D. Form F.P. 113 Fireproofing Aggregates Shotcrete Concrete Masonry Asphalt Roofing P iling S teel S oils Wood November 30, 2016 File No. 16-725 Building Official City of Tukwila Building Department 6300 Southcenter Blvd. Tukwila, WA 98188 Project: Address: Permit: Motion Industries, Inc. 18436 Cascade Ave. S. Suite 160 D16-0288 A.A.R. TESTING LABORATORY, INC. CONSTRUCTION INSPECTION AND MATERIAL TESTING NATIONALLY ACCEPTED I ABORATORY This is to advise you that special inspections are completed on the above referenced project. The following inspection was required and a copy of our inspection report is attached. 1. Proprietary anchor installation To the best of our knowledge all work inspected conformed to Tukwila Building Department approved plans, specifications, IBC and related codes and/or verbal or written instructions from the Engineer of Record. Sincerely, A.A.R. TESTING LABORATORY, INC. Kimberle Anderson President CC: NorthWest Handling Systems, Inc. -Tony Johnson RECEIVED CITY OF TUKWILA NOV 3 0 2016 PERMIT CENTER Tel: (425) 881-5812 Fax (425) 881-5441 •7126 180th Ave. NE • P.O. Box 2523 • Redmond. WA 98073 Field Report Report #: 67584 A.A.R. Testing Laboratory, Inc. 7126 180th Ave.N.E., Park 180, Suite C101, Redmond, WA 98052 Phone 425.881.5812 Fax 425.881.5441 Client: NorthWest Handling Systems, Inc. 1100 SW 7th St. Renton, WA 98055-2939 Contact: Tony Johnson Project Number: 16-725 Permit #: D16-0288 Project Name: Motion Industries, Inc. Address: 18436 Cascade Ave. S. Suite 160 Inspection Performed: Proprietary Anchors Date: !1/21/2016 Time: Temperature: Verified anchors to be Hilti KB -TZ, 1/2" x 4 1/2". Verified hole cleanliness and minimum embedment of 3 1/4". Torque was tested with calibrated wrench and was found meeting the 40 ft. Ib. requirement. All work was completed in conformance with approved plans, manufacturer's recommendations and ESR #1917. All racking noted on sheet #1 was inspected at this time. Distribution: id Distribute Client Li Distribute Contractor pj Distribute Engineer : j D• istribute Owner � 7 Distribute Municipality L✓! D• istribute Other H Distribute Architect ;] Distribute Other Inspector: Chandler, Loren Reviewed by: Michele Guerrini All reports are considered confidential and are the property of the client and A.A.R. Testing Laboratory, Inc. Reproduction except in full without the written consent of A.A.R. Testing is strictly forbidden City of Tukwila Department of Community Development November 08, 2016 NICK HOFFMAN 1100 SW 7TH ST RENTON, WA 98057 RE: Correction Letter # 1 DEVELOPMENT Permit Application Number D16-0288 MOTION INDUSTRIES - 18436 CASCADE AVE S Dear NICK HOFFMAN, Allan Ekberg, Mayor Jack Pace, Director This letter is to inform you of corrections that must be addressed before your development permit can be approved. All correction requests from each department must be addressed at the same time and reflected on your drawings. I have enclosed comments from the following departments: FIRE DEPARTMENT: Al Metzler at 206-971-8718 if you have questions regarding these comments. • 1) Please provide a detailed description of the types of commodities to be stored on the racks. 2) Please provide the total storage height and the ceiling height. ,, ,,� jj.,�v 3) What is the sprinkler density of the existing fire sprinkler system? .�� g4 orf Wait( e, J►f%eL'�'"j g co* 4) What is the temperature rating of the existing ceiling sprinklers? ove -00_, fv- C> (,hr. of SPr/n.Ue' d ,Frain,, (o'—t;/ed 44110 /.f -S-1 ?,5- Please address the comments above in an itemized format with applicable revised plans, specifications, and/or other documentation. The City requires that two (2) sets of revised plan pages, specificions and/or other documentation be resubmitted with the appropriate revision block. Ca4/:L� L i 2 In order to better expedite your resubmittal, a Revision Submittal -Sheet' m accompa y every resubmittal. I have enclosed one for your convenience. Corrections/revisions must be made in person and will not be accepted through the mail or by a messenger service. If you have any questions, I can be reached at 206-431-3655. Sincerely, Bill Rambo Permit Technician File No. D16-0288 CORRECTION LTR# .A4 Til,a‘ax (co 6) — &ri OfPce. Gi3" 7/63 42nn c..:._ 1L1.',1 _ T..l,...:r rai G:_ .. nO/o0 _ _ MEM RECEIVED CITY OF TUKWILA NOV 0 8 2016 PERMIT CENTER NORTHWEST HANDLING SYSTEMS, I N C. The Material Handling Experts 1100 SW 7th St Renton, WA 98057 (425) 255-0500 ph (425) 228-6946 fax ATTN: BUILDING DEPARTMENT AND FIRE DEPARTMENT RACK INFORMATION SUPPLEMENT SITE ADDRESS: 18436 Cascade Ave South. STE 160. Tukwila, WA. TENANT NAME: Motion Industries DATE: October 21, 2016 APPLICANT: Nick Hoffman / 425.902.7222 In answer to Correction Letter #1 provided for Permit application # D16-0288 Fire Department: Al Metzler. 206.971.8718 1. Commodities stored in racks: Bearings, metal parts, small electric motors, gearboxes and Gearbox components, assorted conveyor and material handling components. Seals, gaskets, hand tools, hydraulic pumps and components. Small items are stored in cardboard boxes with minimal packaging material consisting of plastic/bubble wrap and/or paper packaging. Larger items stored on standard GMA, pallet, 40"W x 48"L. 2. Total Storage Height in selective racking: Top beam at 15' (180"). Maximum pallet height on top level, 4' (48") 3. Sprinkler Density: .39/5600 Density / Discharge 4. Temperature Rating: White Sprinkler head - 212* fahrenheit 5. Special inspection of anchor bolts will be performed by AAR Testing Lab. PO Box 2523 Redmond, WA 98073. 425-881-5812. 6. Vertical members of storage racks are designed and installed so that failure of one vertical member will not cause collapse of more than the bay or bays directly supported by that member. CORRECTION RECEIVED CITY CITY OF TUKWILA NOV 0 8 2016 PERMIT CENTER City of Tukwila Department of Community Development November 08, 2016 NICK HOFFMAN 1100 SW 7TH ST RENTON, WA 98057 RE: Correction Letter # 1 DEVELOPMENT Permit Application Number D16-0288 MOTION INDUSTRIES - 18436 CASCADE AVE S Dear NICK HOFFMAN, Allan Ekberg, Mayor Jack Pace, Director This letter is to inform you of corrections that must be addressed before your development permit can be approved. All correction requests from each department must be addressed at the same time and reflected on your drawings. I have enclosed comments from the following departments: FIRE DEPARTMENT: Al Metzler at 206-971-8718 if you have questions regarding these comments. • 1) Please provide a detailed description of the types of commodities to be stored on the .racks. 2) Please provide the total storage height and the ceiling height. 3) What is the sprinkler density of the existing fire sprinkler system? 4) What is the temperature rating of the existing ceiling sprinklers? Please address the comments above in an itemized format with applicable revised plans, specifications, and/or other documentation. The City requires that two (2) sets of revised plan pages, specifications and/or other documentation be resubmitted with the appropriate revision block. In order to better expedite your resubmittal, a 'Revision Submittal Sheet' must accompany every resubmittal. I have enclosed one for your convenience. Corrections/revisions must be made in person and will not be accepted through the mail or by a messenger service. If you have any questions, I can be reached at 206-431-3655. Sincerely, Bill Rambo Permit Technician File No. D16-0288 6300 Southcenter Boulevard Suite #100 • Tukwila Washington 98188 • Phone 206-431-3670 • Fax 206-431-3665 PERMIT COORD COPY. PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: D16-0288 DATE: 11/08/16 PROJECT NAME: MOTION INDUSTRIES SITE ADDRESS: 18436 CASCADE AVE S Original Plan Submittal X Response to Correction Letter # 1 Revision # Revision # before Permit Issued after Permit Issued DEPARTMENTS: Building Division ❑ Public Works ❑ A -t" ASC 11-U04 Fire Prevention Planning Division Structural Permit Coordinator n PRELIMINARY REVIEW: Not Applicable n (no approval/review required) DATE: 11/10/16 Structural Review Required REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: Approved n Approved with Conditions Corrections Required _ Denied (corrections entered in Reviews) (ie: Zoning Issues) DUE DATE: 12/08/16 n Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg D Fire ❑ Ping 0 PW 0 Staff Initials: 12/18/2013 ?ERMIT CORD COPY PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: D16-0288 DATE: 10/26/16 PROJECT NAME: MOTION INDUSTRIES SITE ADDRESS: 18436 CASCADE AVE S X Original Plan Submittal Response to Correction Letter # Revision # Deferred # before Permit Issued after Permit Issued DEPARTMENTS: AT VC, tiny fr Building Division Public Works At\ Com{ Fire Prevention Structural Planning Division ❑ Permit Coordinator PRELIMINARY REVIEW: Not Applicable (no approval/review required) DATE: 10/27/16 Structural Review Required REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: DUE DATE: 11/24/16 Approved Corrections Required ❑ Approved with Conditions ❑ Denied ❑ (corrections entered in. Reviews) (ie: Zoning Issues) Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: 11~ V ' 1 Departments issued corrections: Bldg 0 Fire Ping 0 PW 0 Staff Initials: 12/18/2013 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite # 100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206-431-3665 Web site: http://www.ci.tuk-wila.wa.us Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fax, etc. Date: /I /27/6 6 Plan Check/Permit Number: D 16-0288 ❑ Response to Incomplete Letter # ® Response to Correction Letter # 1 ❑ Revision # after Permit is Issued ❑ Revision requested by a City Building Inspector or Plans Examiner Project Name: Motion Industries Project Address: 18436 Cascade Ave S ,+ 222_SContact Person: AJ/C/ / l''T/ O Phone Number: - `14C 9°4 7;222-- Summary ummary of Revision: ".Flews& 5 »e au facited a to,,r,' P> 574;04 Se, ! Y CITY OF TUKWILA Nov 0 8 2016 Sheet Number(s): PERMIT CENTER "Cloud" or highlight all areas of revision includin date of revi n Received at the City of Tukwila Permit Center by: - Entered in TRAKiT on l (---0-1 \applications\forms-applications on line\revision submittal Created: 8-13-2004 Revised: NORTH WEST HANDLING SYS INC Hoene Espanol Contact Safety & Health Claims & Insurance 0 Washington State Department of Labor & Industries Page 1 of 2 Search L&I A -Z Index Help NIv L&1 Workplace Rights Trades & Licensing NORTH WEST HANDLING SYS INC Owner or tradesperson Principals FRANCK, JAMES JEROME, PRESIDENT KOSTY, CLARK RANDOLPH, TREASURER THOMAS, KEVIN A (End: 09/28/2011) Doing business as NORTH WEST HANDLING SYS INC WA UBI No. 600 051 641 1100 SW 7TH ST RENTON, WA 98055-2939 425-255-0500 KING County Business type Corporation Governing persons CLARK R KOSTY JAMES J FRANCK; License Verify the contractor's active registration / license / certification (depending on trade) and any past violations. Construction Contractor Active. Meets current requirements. License specialties GENERAL License no. NORTHWH275JF Effective — expiration 04/06/1973-10/09/2017 Bond Travelers Cas & Surety Co Bond account no. 815103354822BCM $12,000.00 Received by L&I Effective date 10/09/2001 10/01/2001 Expiration date Until Canceled Insurance Travelers Indemnity Company Th $1,000,000.00 Policy no. Y6302C242044TIA16 Received by L&I Effective date 09/30/2016 10/01/2016 Expiration date 10/01/2017 Insurance history Savings Help us improve https://secure.lni.wa.gov/verify/Detail.aspx?UBI=600051641 &LIC=NORTHWH275JF&SAW= 11/22/2016 SHEET NUMBER 24x48 24x48 24x48 24x48 24x48 24x48 24x48 24x48 24x48 24x48 24x48 24x48 24x48 24x48 24x48 24x48 24x48 24x48 24x48 24x48 24x48 24x48 24x48 24x48 24x48 24x48 24x48 24x48 24x48 24x48 24x48 24x48 24x48 24x48 24x48 24x48 24x48 24x48 24x48 24x48 24x48 24x48 24x48 24x48 24x48 24x48 24x48 24x48 24x48 24x48 24x48 24x48 24x48 24x48 1 24x48 II 24x48 24x48 24x48 24x48 24x48 24x48 24x48 24x48 1 24x48 24x48 24x48 24x48 24x48 24x48 24x48 24x48 24x48 24x48 24x48 24x48 24x48 24x48 24x48 24x48 24x48 24x48 24x48 44X120 24x48 24x48 44X120 44X96 44X96 44X96 44X96 44X96 44X96 44X96 44X96 44X9 44X96 44X96 44X96 44X96 44 44X96 44X96 444-6,-` 44X96 44X96 44X96 44X96 44549-6\ 44X96 44X96 4'X8' SMOKE/HEAT VENT t ,.7oLiunical Liectrical Vii' lurnbing Os Piping of Tukwila �► ..__;7::!0 DIVISION 44X96 44X96 44X96 44X96 44X96 44X96 44X96 44X96 REVISIONS No changes shall be mad of work without prior a T k .►ila Building 0 NOTE: R avisicns will require a and may include additional pl. REVIEWED FOR CODE COMPLIANCE APPROVED PLAN VIEW SCALE: 1/8" = 1'-0" 44X96 44X96 44X96 44X96 44X96 44X96 44X96 44X96 36x48 36x48 36x48 FILEtt(p- COPY Permit No. O) j Plan review approval is subject to errors and omissions. Approval of construction documents does not authorize the violation of any adopted code or ordinance. Receipt of approved Field Copy a d '41tions is acknowledged: By: Date: f/ City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA OCT 21 2016 PERMIT CENTER DRAWING NUMBER 1 TYP ^ ,-'•. 1 3/4" ��� 3/8 "0 AST 6 ,A3 Vell T5 30/ ti ® 61, 0 ® �i, 7 t �� 1� 0 Imo i /' `' �l -,:X°.`% 0 • :� 100 01 rn 4•, 'maLo y �/� , �,� I I I 00 I \ �/ r, �. I , iii 1 fir G� ,. /�� $ 4- I I I t=0.06" ----------� BOTH SIDES TYP. �� \ 1 /8 r1.5 \ \ \ \ i ) / ❑ . 1 /8 (� (� 1/4"o (1 000 - SAFETY LOCK # CAPACITY) 0 to: H t1TT —t 1 1 gza 0 U 0 c:3 1 " SEC. A—A , °...a ,. :. °' °, •. o Q . ; .. .. ' . .° ° 5 \ \a P ° ° .° ° ... •ptl ° ° a• 1/8IF 1 /8 '1.5" / / / / / // ❑ 6" t=3/8" ` • r 8" , / N ! 2)-1 (2)-1/2"o 3 /2"o ANCHOR BOLTS PER BASE PLATE 1/4" EMB., (SEE NOTE N0. 4) ---- — a N 1 i SEC. B—B 7/16"0 RIVET ASTM A576-908 ' " HOT—WROUGHT UNS G10100 GRACE C-1010 t=3/16" BASE PLATE DETAIL BRACING DETAIL 3 PIN CONNECTION 3D ROW SPACER 4 44 r 1 ' 0 4 ° ° p 0 ° ° p p ° y / pIr °Q °00 o0 ° 4 4 ° °00 r Or r Q Q OQ r 0 00 '1 o Qp r Q °► ° ° ° n ° ° p 1 ° p ° p p ° a 0 I I I ° °0 °0 o °00 ° p 4° 4° °aQ ► ° ° °00 0° ° o 0 0 0 0 0 QQ Q P 0 Q 0 0 0 0 0 Q 0 0 fl .. t . CORDEAEVPICE®OWOP Nov 18 CIS of BUILDING RCE DLEFIIION 26 Tukwila DIVISION GENERAL CONFIGURATION 5 96" 44" 44" 44" NOTES: 1—DESIGN OF STEEL STORAGE RACKS AS SHOWN BY THESE DRAWINGS AND CALCULATIONS ARE IN COMPLIANCE WITH THE REQUIREMENTS OF THE IBC 2012/2015, ASCE/SEI 7-10, ACI 318-11, RMI/ANSI 2—STEEL FOR ALL SHAPES FY=55 KSI. ASTM A1011 GR.55 (EXCEPT 3—NO FIELD WELDING IN THIS PROJECT ALL WELDED CONSTRUCTION OF THE APPROVED FABRICATOR #01649 (E70XX ELECTRODES) 4—ALL ANCHORS HILTI KB—TZ, ESR -1917 SPECIAL INSPECTION IS REQUIRED 5—CONCRETE SLAB 6" THICK 2500 PSI. SOIL BEARING CAPACITY 1000 6—STORAGE RACK CAPACITY 2500 #/ LEVEL 7—RACK INSTALLATIONS SHALL DISPLAY IN ONE OR MORE CONSPICUOUS A PERMANENT SIGN OF 50 SQUARE INCHES IN AREA, SHOWING THE OF THE RACK (2500 #/ LEVEL) 8—STORAGE RACKS SHALL BE INSTALLED WITH A MAXIMUM TOLERANCE VERTICAL OF 1 /2" IN 10'-0" OF HEIGHT 9—THE CLEAR SPACE BELOW SPRINKLERS SHALL BE A MINIMUM OF BETWEEN THE TOP OF THE STORAGE AND THE CEILING SPRINKLER 10—STORAGE RACK AREA NOT OPEN TO PUBLIC, EMPLOYEE ACCESS RECEIVED CITY OF OCT PERMIT MH 16.1:2012 AS NOTED) IN THE SHOP PSF LOCATIONS CAPACITY FROM THE 18 INCHES DEFLECTOR. ONLY TUKWILA 2 1 2016 CENTER 1 1 1 _ 1 — �� — _ °O� 4- _i/ `f C di 4 a t \ \N RCN Of { \ '� 3 \ 3 °/ I t4- ALL LEVELS \ / �t ocNi Rd- \ • t • �KOx. 81R �4ti °�. W9G cr9 �r.Q' 412 WEST BROADWAY, SUITE #204, GLENDALE, CA. 91204 plc — —. CO� 'rco — . �" � SCALE: NONE DRAWN BY: A.KH. .. r DATE: 10-20-16 ;;►� s385>z .c4.• k�.� /�o \, PROJECT: MOTION INDUSTRIES, INC 18436 �„� E s£�UTH, TUKWILA, 98 °8 FRONT VIEW SIDE VIEW .-� .� �� �'� a .► .�.--• ;j �' j�r ��t Asa �� STORAGE RAC�� �illiIYIF$flll. �}� �7 �t��' I� � `'�"`' EXPIRES 12-26-17