HomeMy WebLinkAboutPermit D16-0288 - MOTION INDUSTRIES - STORAGE RACKINGMOTION INDUSTRIES
18436 CASCADE AVE S 160
D16-0288
Parcel No:
Address:
City of Tukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206-431-3670
Inspection Request Line: 206-438-9350
Web site: http://www.TukwilaWA.gov
DEVELOPMENT PERMIT
7888900030
18436 CASCADE AVE S 160
Project Name: MOTION INDUSTRIES
Permit Number: D16-0288
Issue Date: 11/22/2016
Permit Expires On: 5/21/2017
Owner:
Name:
Address:
Contact Person:
Name:
Address:
Contractor:
Name:
Address:
License No:
Lender:
Name:
Address:
CPF KENT VALLEY LLC
100 WILSHIRE BLVD #700 , SANTA
MONICA, WA, 90401
NICK HOFFMAN
1100 SW 7TH ST, RENTON, WA, 98057
NORTH WEST HANDLING SYS INC
1100 SW 7TH ST, RENTON, WA, 98055
NORTHWH275JF
MOTION INDUSTRIES
18436 CASCADE AVE S , TUKWILA, WA,
98188
Phone: (425) 902-7222
Phone: (206) 255-0500
Expiration Date: 10/9/2017
DESCRIPTION OF WORK:
RACKING
Project Valuation: $47,800.00
Type of Fire Protection:
Sprinklers: YES
Fire Alarm: YES
Type of Construction: VB
Electrical Service Provided by: TUKWILA
Fees Collected: $1,623.42
Occupancy per IBC: B
Water District: TUKWILA
Sewer District: TUKWILA
Current Codes adopted by the City of Tukwila:
International Building Code Edition:
International Residential Code Edition:
International Mechanical Code Edition:
Uniform Plumbing Code Edition:
International Fuel Gas Code:
2015
2015
2015
2015
2015
National Electrical Code:
WA Cities Electrical Code:
WAC 296-46B:
WA State Energy Code:
2014
2014
2014
2015
Public Works Activities:
Channelization/Striping:
Curb Cut/Access/Sidewalk:
Fire Loop Hydrant:
Flood Control Zone:
Hauling/Oversize Load:
Land Altering:
Landscape Irrigation:
Sanitary Side Sewer:
Sewer Main Extension:
Storm Drainage:
Street Use:
Water Main Extension:
Water Meter:
Volumes: Cut: 0 Fill: 0
Number: 0
No
Permit Center Authorized Signature:
US- Date: L I %6
I hearby certify that I have read and examined this permit and know the same to be true and correct. All
provisions of law and ordinances governing this work will be complied with, whether specified herein or not.
The granting of this permit does not presume to give authority to violate or cancel the provisions of any other
state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this
development permit and agree to, conditions attached to this permit.
Signature:
Print Name:
,f/•cK arl
Date: // Z2//�
This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if
the work is suspended or abandoned for a period of 180 days from the last inspection.
PERMIT CONDITIONS:
1: ***BUILDING PERMIT CONDITIONS***
2: Work shall be installed in accordance with the approved construction documents, and any changes made
during construction that are not in accordance with the approved construction documents shall be
resubmitted for approval.
3: All permits, inspection record card and approved construction documents shall be kept at the site of work
and shall be open to inspection by the Building Inspector until final inspection approval is granted.
4: When special inspection is required, either the owner or the zegistered design professional in responsible
charge, shall employ a special inspection agency and notify the Building Official of the appointment prior to
the first building inspection. The special inspector shall furnish inspection reports to the Building Official in
a timely manner.
5: A final report documenting required special inspections and correction of any discrepancies noted in the
inspections shall be submitted to the Building Official. The final inspection report shall be prepared by the
approved special inspection agency and shall be submitted to the Building Official prior to and as a
condition of final inspection approval.
6: All construction shall be done in conformance with the Washington State Building Code and the
Washington State Energy Code.
7: All rack storage requires a separate permit issued through the City of Tukwila Permit Center. Rack storage
over 8 -feet in height shall be anchored or braced to prevent overturning or displacement during seismic
events. The design and calculations for the anchorage or bracing shall be prepared by a registered
professional engineer licensed in the State of Washington. Periodic special inspection is required during
anchorage of storage racks 8 feet or greater in height.
8: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila
Permit Center.
9: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an
approval of, any violation of any of the provisions of the building code or of any other ordinances of the City
of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other
ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction
documents and other data shall not prevent the Building Official from requiring the correction of errors in
the construction documents and other data.
12: The total number of fire extinguishers required for an ordinary hazard occupancy with Class A fire hazards is
calculated at one extinguisher for each 1,500 sq. ft. of area. The extinguisher(s) should be of the "AII
Purpose" (3A, 40B:C) dry chemical type. Travel distance to any fire extinguisher must be 75' or less. (IFC
906.3) (NFPA 10, 5.4)
10: Portable fire extinguishers, not housed in cabinets, shall be installed on the hangers or brackets supplied.
Hangers or brackets shall be securely anchored to the mounting surface in accordance with the
manufacturer's installation instructions. Portable fire extinguishers having a gross weight not exceeding 40
pounds (18 kg) shall be installed so that its top is not more than 5 feet (1524 mm) above the floor. Hand-
held portable fire extinguishers having a gross weight exceeding 40 pounds (18 kg) shall be installed so that
its top is not more than 3.5 feet (1067 mm) above the floor. The clearance between the floor and the
bottom of the installed hand-held extinguishers shall not be less than 4 inches (102 mm). (IFC 906.7 and IFC
906.9)
11: Extinguishers shall be located in conspicuous locations where they will be readily accessible and
immediately available for use. These locations shall be along normal paths of travel, unless the fire code
official determines that the hazard posed indicates the need for placement away from normal paths of
travel. (IFC 906.5)
13: Maintain fire extinguisher coverage throughout.
16: Maintain fire alarm system audible/visual notification. Addition/relocation of walls or partitions may
require relocation and/or addition of audible/visual notification devices. (City Ordinance #2437)
15: AII new fire alarm systems or modifications to existing systems shall have the written approval of The
Tukwila Fire Prevention Bureau. No work shall commence until a fire department permit has been
obtained. (City Ordinance #2437) (IFC 901.2)
17: Clearance between ignition sources, such as light fixtures, heaters and flame -producing devices, and
combustible materials shall be maintained in an approved manner. (IFC 305.1)
18: Where storage height exceeds 15 feet and ceiling sprinklers only are installed, fire protection by one of the
following methods is required for steel building columns located within racks: (a) one-hour fire proofing,
(b) sidewall sprinkler at the 15 foot elevation of the column, (c) ceiling sprinkler density minimums as
determined by the Tukwila Fire Prevention Bureau. (NFPA 13-16.1.4)
19: Storage shall be maintained 2 feet or more below the ceiling in nonsprinklered areas of buildings or a
minimum of 18 inches below sprinkler head deflectors in sprinklered areas of buildings. (IFC 315.3.1)
20: Flue spaces shall be provided in accordance with International Fire Code Table 3208.3. Required flue
spaces shall be maintained.
14: Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (City Ordinances
#2436 and #2437)
21: Any overlooked hazardous condition and/or violation of the adopted Fire or Building Codes does not imply
approval of such condition or violation.
22: These plans were reviewed by Inspector 511. If you have any questions, please call Tukwila Fire Prevention
Bureau at (206)575-4407.
PERMIT INSPECTIONS REQUIRED
Permit Inspection Line: (206) 438-9350
1700 BUILDING FINAL**
1400 FIRE FINAL
4046 SI-EPDXY/EXP CONC
CITY OF TUK► ,A
Community Development Department
Public Works Department
Permit Center
6300 Southcenter Blvd., Suite 100
Tukwila, WA 98188
http://www.TukwilaWA.gov
Building Peri lit No.
Project No.
Date Application Accepted: O
Date Application Expires: I l'
(For office use on y,
CONSTRUCTION PERMIT APPLICATION
Applications and plans must be complete in order to be accepted for plan review.
Applications will not be accepted through the nail or by fax.
**Please Print**
SITE LOCATION
?-88890:030
ea
,,--_/ //�� C King Co Assessor's Tax No.: '78Q g ?ffle�30
Site Address: /N36 CSS -a-0 & /IVPs $04 Suite Number: /60 Floor: r�%v not
Tenant Name: ,A10 O +(0r7 vSTi J Pry New Tenant: Yes ❑ ..No
((cork, (4 A 6781A
PROPERTY OWNER
Name: a' i
hen4- Valley , Lt _
Address: 300 pc564v-te 5 &Jay Scw 4'30t
City: vim,7 fn aii...,„r State: w A Zip: 'f 01
CONTACT PERSON - person receiving all project
communication
Name: /1/6 k Af.� t ti
y
Address: ,i/ 5fiit)J7 im 5.
City: gjeit/vn State: toh Zip:cgoS3-
Phone: (t/ZS) qoz.-?zzz Fax: (y.25 -22,2,g rG el. y6
Email: m P (✓(C 1f e A (,c) f S • C00'1
GENERAL CONTRACTOR INFORMATION
Company Name: NOr11, )eG (,1a._ ji ss OW
(1 rlv
Address: /100 .561)9,1.-
City: Row-bn State: () A Zip: 9 s, -
Phone: (,,a,-.) 2s -oSa? Fax: (car) zz2 - b ?e(
Contr Reg No.:Ivo_ Ker_ Ho. Hzts4p Date: /Z(31 J/b
Tukwila Business License No.: /5v5 0qct 4oy.-
H:\Applications\Forms-Applications On Line \2011 Applications\Perntit Application Rcviscd - 8-9-11.docx
Rcviscd: August 2011
bh
ARCHITECT OF RECORD
Company Name:, ' j pe5dyh 1 67ee/
Company Name: .601 20.�, ((Sa
l 1�
lm to '(,,./' .
/ �1
Architect Name:
Phone:: 4e/8) .,2 _ 3910 Fax:
Address: 3y 3 W Ga t`
0a,,,,,,A P y 56
City: ee`/ , e., State:/u4 Zip: 9 v
Phone(gz) G`lf 08� Fax:
/,�
Email:`` N/4
ENGINEER OF RECORD
Company Name:, ' j pe5dyh 1 67ee/
Engineer Name:Com./Mk G an/OM
Address: e//.z 42 e oa war s' 20'1
City: je,z a (e..,. State: e 4` Zip: *WI/
( y
Phone:: 4e/8) .,2 _ 3910 Fax:
Email: 1' (4 D65 1 0A) y.01r.M tit .601/4
LENDER/BOND ISSUED (required for projects $5,000 or
greater per RCW 19.27.095)
Name:
/ I�
040'I_Gitls4i-eS-'5iITAdeot
Address
!
f/(../T jam
City:
State: [, Zip:
Page 1 of 4
BUILDING PERMIT INFORMATI( 206-431-3670
Valuation of Project (contractor's bid price): $ if 7 j ZOO Existing Building Valuation: $
Describe the scope of work (please provide detailed information):
„fin 5-1a Hwy s of Ail AA &,tk 1 a /0/ 41-y S o bcv e/e>lz6eri 5k/1
$ePi a / tcheeC drawn 5 a 5 ea/c. (ons (41.4 ecvfa-lions
.4R
Will there be new rack storage? 1511. Yes
❑.. No If yes, a separate permit and plan submittal will be required.
Provide All Building Areas in Square Footage Below
PLANNING DIVISION:
Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches)
*For an Accessory dwelling, provide the following:
Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling:
*Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence.
Number of Parking Stalls Provided: Standard: Compact:
Handicap:
Will there be a change in use? ❑ Yes 0 No If "yes", explain:
FIRE PROTECTION/HAZARDOUS MATERIALS:
71, Sprinklers Automatic Fire Alarm D None ❑ Other (specify)
Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes No
If `yes', attach list of materials and storage locations on a separate 8-1/2"x 11" paper including quantities and Material Saf-ty lata Sheets.
SEPTEPT~WE'NM
0 On-site Septic S
De
— For on
ic.system, provide 2 copies of a current septic design approved by King County Health
H:\Applications\Forms-Applications On Line \2011 Applications\Pcrmit Application Rcviscd - 8-9-1 I.docx
Revised: August 2011
bh
Page 2 of 4
Existing
Interior Remodel
Addition to
Existing
Structure
New
Type of
Construction per
IBC
Type of
Occupancy per
IBC
151 Floor
.Z 11 5-Y
I
2, /46 s •7
F%//et Ra/
v
V
fI,
�✓
rd Floor
.rte
Shaw,.
3rd Floor
----
Floors thru
Floors
Basement
Accessory Structure*
Attached Garage
.------
Detached Garage
Attached Carport
Detached Carport
Covered Deck
1 ----
Uncovered Deck
PLANNING DIVISION:
Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches)
*For an Accessory dwelling, provide the following:
Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling:
*Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence.
Number of Parking Stalls Provided: Standard: Compact:
Handicap:
Will there be a change in use? ❑ Yes 0 No If "yes", explain:
FIRE PROTECTION/HAZARDOUS MATERIALS:
71, Sprinklers Automatic Fire Alarm D None ❑ Other (specify)
Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes No
If `yes', attach list of materials and storage locations on a separate 8-1/2"x 11" paper including quantities and Material Saf-ty lata Sheets.
SEPTEPT~WE'NM
0 On-site Septic S
De
— For on
ic.system, provide 2 copies of a current septic design approved by King County Health
H:\Applications\Forms-Applications On Line \2011 Applications\Pcrmit Application Rcviscd - 8-9-1 I.docx
Revised: August 2011
bh
Page 2 of 4
PUBLIC WORKS PERMIT INF( IATION — 206-433-0179
Scope 1, f Work (please provide detailed information):
Water District
❑ ...Tukwila
❑ ...Water Availability Provided
Call before you Dig: 811
Please refer to Public Works Bulletin #1 for fees and estimate sheet.
Sewer District
❑ ...Tukwila
0 ...Sewer Use Certificate
Septic System:
❑ On-site Septic System — For on-site septic sys em, provide 2 copies of a current septic design appr ed by King County Health Department.
...Water District #125
0 .. Highline
❑ ... Va ey View ❑ .. Renton
❑ ... Sewe vkvailability Provided
0 .. Renton
❑ .. Sea e
Submitted with Application (mark boxes which applv):
❑ ...Civil Plans (Maximum Paper Size — 22" x 34")
❑ ...Technical Information Report (Storm Drainage)
0 ...Bond 0 .. Insurance ❑ .. Easement'(
Proposed Activities (mark boxes that apply):
❑ ...Right-of-way Use - Nonprofit for less than 72 hours
0 ...Right-of-way Use - No Disturbance
0 ...Construction/Excavation/Fill - Right-of-way 0
Non Right-of-way ❑
0 ...Total Cut
❑ ...Total Fill
cubic yards
cubic yards
❑ ...Sanitary Side Sewer
❑ ...Cap or Remove Utilities
0 ...Frontage Improvements
❑ ...Traffic Control
0 ...Backflow Prevention - Fire Protection
Irrigation
Domestic Water
0 .. Geotechnical Report
❑ ...Traffic Impact Analysis
❑ .. Maintenance Agreenpent(s) 0 ...Hold Harmless — (SAO)
❑ ...Hold Harmless — (ROW)
..Right-of-way ase - Profit for less than 72 hours
n.. Right-of-wa Use — Potential Disturbance
❑ .. Wor ,'4 Flood Zone
❑ .. Sto rainage
❑ .. Abandon Septic Tank
❑ .. Curb Cut
0 .. Pavement Cut
❑ .. Looped Fire Line
❑ ...Permanent Water Meter Size... WO #
❑ ...Temporary Water Meter Size .. WO
❑ ...Water Only Meter Size W 4 # ❑ ...Deduct Water Meer Size
0 ...Sewer Main Extension Public 0 .'rivate ❑
❑ ...Water Main Extension Public 0 Private 0
❑ .. Grease Interceptor
❑ .. Channelization
0 .. Trench Excavation
❑ .. Utility Undergrounding
FINANCE INFORMATION
Fire Line Size at Property Line
0 ...Water 0 ...Sew
Monthly Service Billing to:
Name:
Mailing Address:
r
Number of Public Fire Hydrant(s)
0 ...Sewage Treatment
Day Telephone:
Water Meter Refund/Billing:
Name: /
Mailing Address:
City
State
Z
p
Day Telephone:
City State Zip
H:\Applications\Fomu-Applications On Line \2011 Applications\Pcrmit Application Revised - 8-9-11.docx
Revised: August 2011
bh
Page 3 of 4
PERMIT APPLICATION NOTES —
Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject
to possible revision by the Permit Center to comply with current fee schedules.
Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation.
The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be
requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition).
I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER
PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT.
BUILDING OWNER
Signature:
Print Name:
RIZED AGENT:
A
e -k m»mav►
Mailing Address:
1/00 $cA)
Date: /.°7/1/4
Day Telephone: 611 s) 9oz _ �Z2 2-
R CIDIVI
RCIDIVI 60.4 i'oas"7i
H:\Applications\Forms-Applications On Line \2011 Applications\permit Application Rcviscd - 8-9-11.docx
Revised: August 2011
bh
City State Zip
Page 4 of 4
Cash Register Receipt
City of Tukwila
DESCRIPTIONS I ACCOUNT QUANTITY
PermitTRAK
PAID
$1,623.42
D16-0288 Address: 18436 CASCADE AVE 5 160 Apn: 7888900030
$1,623.42
DEVELOPMENT
$1,575.80
PERMIT FEE
R000.322.100.00.00
0.00
$952.30
PLAN CHECK FEE
R000.345.830.00.00
0.00
$619.00
WASHINGTON STATE SURCHARGE
8640.237.114
0.00
$4.50
TECHNOLOGY FEE
$47.62
TECHNOLOGY FEE
TOTAL FEES PAID BY RECEIPT: R9711
R000.322.900.04.00 0.00
$47.62
$1,623.42
Date Paid: Friday, October 21, 2016
Paid By: NICHOLAS HOFFMAN
Pay Method: CREDIT CARD 021948
Printed: Friday, October 21, 2016 12:58 PM 1 of 1
CIRWSYSTEMS
BILE
NORTHWEST
HANDLING SYSTEMS, I N C.
The Material Handling Experts
1100 SW 7th St
Renton, WA 98057
(425) 255-0500 ph
(425) 228-6946 fax
ATTN: BUILDING DEPARTMENT AND FIRE DEPARTMENT
RACK INFORMATION SUPPLEMENT
SITE ADDRESS: 18436 Cascade Ave South. STE 160. Tukwila, WA.
TENANT NAME: Motion Industries
DATE: October 21, 2016
APPLICANT: Nick Hoffman / 425.902.7222
In answer to Correction Letter #1 provided for Permit application # D16-0288
Fire Department: Al Metzler. 206.971.8718
REVIEWED FOR
CODE COMPLIANCE
APPROVED
NOV 1 8 2016
City of Tukwila
BUILDING DIVISION
1. Commodities stored in racks: Bearings, metal parts, small electric motors, gearboxes and
Gearbox components, assorted conveyor and material handling components. Seals, gaskets,
hand tools, hydraulic pumps and components. Small items are stored in cardboard boxes
with minimal packaging material consisting of plastic/bubble wrap and/or paper packaging.
Larger items stored on standard GMA. pallet, 40"W x 48"L.
2. Total Storage Height in selective racking: Top beam at 15' (180"). Maximum pallet height
on top level, 4' (48")
3. Sprinkler Density: .39/5600 Density / Discharge
4. Temperature Rating: White Sprinkler head - 212* fahrenheit
5. Special inspection of anchor bolts will be performed by AAR Testing Lab. PO Box 2523
Redmond, WA 98073. 425-881-5812.
6. Vertical members of storage racks are designed and installed so that failure of one vertical
member will not cause collapse of more than the bay or bays directly supported by that
member.
RECEIVED
CITY OF TUKWILA
CORRECTION - NOV 08 2016
LTR#
PERMIT CENTER
BY G. OHANIAN RAGiK DEOIdN & ENcINEERINd do.
DATE. 10-20-16
SUBJECT
412 WEOT BROADWAY, 61UITE #204
C LENDALE, dA. 91204
TEL:(818)240-3810 FAX:(818)240-3813
SHEET NO. 1
JOB NO.. RD -18720
STRUCTURAL CALCULATIONS OF STORAGE ,�r� n
RACKS FOR:. U IeI
MOTION IND.
18436 CASCADE AVE SOUTH
TUKWILA, WA 98188
PER IBC 2012/2015 SEC. 2209.1
ASCE 7-10 SEC. 15.5.3
RMI/ANSI/MH 16.1:2012
STORAGE RACKS CAPACITY:
2500 # / LEVEL
CALCS. 1 THRU 4
DRAWINGS: RD -18720
REVIEWED FOR
LODE COMPLIANCE
a' APPROVED
NOV 18 2016
City of Tukwila
BUILDING DIVISION
EXPIRES 12-26-17
RECEIVED
CITY OF TUKWILA
OCT 21 2016
PERMIT CENTER
DUe c'245
BY G. OHANIAN RAdK DEOI(4N & ENOINEERINGt do.
DATE 10-20-16
SUBJECT
412 WEOT BROADWAY, BUITE #204
LENDALE, dA. 91204
TEL:(818)240-3810 FAX:(818)240-3813
SHEET NO 2
JOB NO.. RD -18720
.00
96"
1
1
{
BEAM DESIGN
SEISMIC DESIGN
_SDS KI
v=
Rx 1 .4 xW
Ix=1.63
Sx =.77
FY= 55 KSI.
d
LOAD PER BEAM + 25% IMPACT LOAD
(2.5Kx.88)+(1.2Kx.25) = 2.5— 1.3K
2 2 BEAMS
M= 8 =15""K
S R= .46<.77
4
384.1x .E 180 —
IBC 2012/2015 SEC. 2209.1
ASCE 7-10 SEC. 15.5.3, RMI/ANSI/MH 16.1:2012
S Ds =0.94 (USGS WEB SITE, "SITE CLASS D")
1=1 NO PUBLIC ACCESS
R=6 MOM. CONN. RMI 2.6 AND 2.6.3
R=4 BRACED
W=D.L.+ 3 PALLET LOAD
LOAD PER COL. = 3x2.5 K =3.8 K
2 ca.
P=.2DL+ (3.8Kx0.75)=3.0K
W=.2DL+ (3.8PLx0.67)= 2.7 K
V LONGIT.NGIT. 30 K
V = .46K
TRANS.
LONGIT. SEISMIC
.30K
3.8"K
5 8"K
7.6"K
7.6 "K
BY G. OHANIAN RACK DEOI(N & ENGtINEERINC CO.
DATE. 10-20-16
SUBJECT
412 WET BROADWAY, PUITE #204
LENDALE, dA. 91204
TEL:(818)240-3810 FAX:(818)240-3813
SHEET NO 3
JOB NO.. RD -18720
COLUMN DESIGN
3"
- — x
1I� M
t=.070"
COMBINED STRESS RATIO
Pex= (KL.,x =71.0
ax=1— PCP = .92
Fy=55 KSI
Ae=.62
I x=.95
S8=.6
rx=1.2
ry=1.1
f2c=1.8
Db=1.67
Cmx=.85
BASE PLATE
ANCH. TENSION = 0
ANCHOR SHEAR — .15 K
KL _52x1.2 =52
rx 1.2
KL =14.0_ -36
Y •
Mr,=Se.Fy= 35
Qc.P+ Qb.Cmx.M = .53<1
Pr, Mn.ax
(2)-1/2"0 ANCHORS PER BASE PL., 3 1/4" EMB.
HILTI KWIK BOLT—TZ ESR -1917
SPECIAL INSPECTION IS REQUIRED
MOMENT AT BEAM CONNECTION
.5x.07x1 x65=2.3 K BEARING CAPACITY
OF COL. HOLE
7/16"0 RIVET
A = .1 Fy = 79 KSI
Pa = .1x79x.4 = 3 K
Ma = (2.3Kx4")+(1.1 Kx2") = 11.4"K 3 PIN CONN.
CONN.
MEND—.O1xWI2= 1.2 K
M = 6.7"K
SEISMIC
M =7.9"K
TOTAL
2
Fe= (KLj2= 108
rx
2
F r,=F y(.658 c )=44 KSI
Pr,= Fr, .Ae = 28.0 K
5.7 'K
Ac=-\/Fy/Fe = 0.71
Nc<1.5
BY G. OHANIAN RAdK DEOI N & EN(INEERIN(4 do.
412 WET BROADWAY, QUITE #204
LENDALE, dA. 91204
TEL:(818)240-3810 FAX:(818)240-3813
DATE. 10-20-16
SUBJECT
SHEET NO. 4
JOB NO. RD -18720
OVERTURNING
MOT =.46 Kx2 x172"x0.66 =103 "K
co.L
MR = 3.0Kx44"= 133"K
NO UPLIFT
LOAD TO DIAGONAL
P=.46Kx2 x52 =1.1K
COL. 42
FY =55 KSI
Ae=.26
rx =.48
L= 52"
Pa= 3.1 K
CHECK WELDS
p°= (1_.01L)L.t.Fa = 4.4K
0= 2.55
= 1.7Kx2 = 3.4K
SIDES
CHECK SLAB
3000 =3.0 °'
1000
.46 K
3.Ox 144=432 °''
J' 432=21"
M= ( �'2 2 x 1000x 2
S= 12x62 / x12=2344 "#
\= 72
6
2344 = 33 <1.6 J 2500 =80
72
.46 K
44"
N
\ O
a a
I0
•
TOP LEVEL LOADING
W= 0.2DL+1.3LL=1.5K LOAD PER COL.
V= .24 K
MOT=.24Kx cox152"=74"K
MR = 1.5 Kx44" = 64"K
UPLIFT = 77 44 -.23 K
BOTH SIDES TYP. 1 5"
1
x -F9 -x
r- \
t=.06"
3000 #
6" CONCRETE SLAB
2500 PSI. CONC.
1000 PSF. SOIL
INSPECTION RECORD
Retain a copy with permit
INSPECTION -NO. PERMIT NO.
CITY OF TUKWILA BUILDING DIVISION
6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670
Permit Inspection Request Line (206) 438-9350
bi6-G2b6
Project:)
/rnoi7c,i / AIWS1 his
Typ of Inspection:
ISU 11 /AG- tAl/41. .
Address:
/PRO 04sc4i
/kir g
Date Called:
Special Instructions:
/66
Date Wanted: /a
2 7 A A-1-11
a.m.
P.m.
Requester:
/J, CK'
Phone No:
q2S = 90Z- 7202,
Approved per applicable codes. , LJ Corrections required prior to approval.
COMMENTS:
OK T�
Inspector:At)
Apti
Date:' Z 9 J
REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be
paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection.
INSPECTION RECORD
Retain a copy with permit
b' -CZ36
PERMIT NO.
CITY OF TUKWILA BUILDING DIVISION
6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670
Permit Inspection Request Line (206) 438-9350
\Kr
Project:
/*VOA/ bib OSMCS
Type of Inspection:
1 LbidLer rAfA ,...
Address:
/P1136 CASeAbe
j o&M u- LeAbi e-
;
5
Date Called:
Special Instructions:
)
/
®
Date Wanted /
%i 30 � (o ,4-&
�
a.m.
P.m.
Requester:
Phone No:
2o6 -5/b -12g0
Approved per applicable codes. RI Corrections required prior to approval.
COMMENTS:
t.
j o&M u- LeAbi e-
.fig-
42.6- pr--- »✓
LAB
Inspector:A
REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be
paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection.
INSPECTION NUMBER
INSPECTION RECORD
Retain a copy with permit
Ib -C 2.
PERMIT NUMBERS
CITY OF TUKWILA FIRE DEPARTMENT
206-575-4407
Project:
0(16f t00 I0()vsl»i5
Type of Inspection:
-1/---
Address: i ``
Suite#: J3/- casco k I've S /
Contact Person:
Special Instructions:
Phone No.:
KApproved per applicable codes.
Corrections required prior to approval.
COMMENTS:
,ze-- 01-6- (N/ c c fs (l 6-67--/O,,3
Needs Shift Inspection:
Sprinklers:
Fire Alarm:
Hood & Duct:
Monitor:
Pre -Fire:
Permits:
Occupancy Type:
Inspector: f vl 5.--A, 1rj;
Date: /y /i f , b
Hrs.:
$100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from
the City of Tukwila Finance Department. Call to schedule a reinspection.
Billing Address
Attn:
Company Name:
Address:
City:
State:
Zip:
Word/Inspection Record Form.Doc
3/14/14
T.F.D. Form F.P. 113
Fireproofing
Aggregates
Shotcrete
Concrete
Masonry
Asphalt
Roofing
P iling
S teel
S oils
Wood
November 30, 2016
File No. 16-725
Building Official
City of Tukwila Building Department
6300 Southcenter Blvd.
Tukwila, WA 98188
Project:
Address:
Permit:
Motion Industries, Inc.
18436 Cascade Ave. S. Suite 160
D16-0288
A.A.R. TESTING
LABORATORY, INC.
CONSTRUCTION INSPECTION AND MATERIAL TESTING
NATIONALLY ACCEPTED I ABORATORY
This is to advise you that special inspections are completed on the above
referenced project. The following inspection was required and a copy of our
inspection report is attached.
1. Proprietary anchor installation
To the best of our knowledge all work inspected conformed to Tukwila Building
Department approved plans, specifications, IBC and related codes and/or
verbal or written instructions from the Engineer of Record.
Sincerely,
A.A.R. TESTING LABORATORY, INC.
Kimberle Anderson
President
CC: NorthWest Handling Systems, Inc. -Tony Johnson
RECEIVED
CITY OF TUKWILA
NOV 3 0 2016
PERMIT CENTER
Tel: (425) 881-5812 Fax (425) 881-5441 •7126 180th Ave. NE • P.O. Box 2523 • Redmond. WA 98073
Field Report Report #: 67584
A.A.R. Testing Laboratory, Inc. 7126 180th Ave.N.E., Park 180, Suite C101, Redmond, WA 98052
Phone 425.881.5812 Fax 425.881.5441
Client: NorthWest Handling Systems, Inc.
1100 SW 7th St.
Renton, WA 98055-2939
Contact: Tony Johnson
Project Number: 16-725
Permit #: D16-0288
Project Name: Motion Industries, Inc.
Address: 18436 Cascade Ave. S. Suite 160
Inspection Performed: Proprietary Anchors
Date: !1/21/2016
Time:
Temperature:
Verified anchors to be Hilti KB -TZ, 1/2" x 4 1/2". Verified hole cleanliness and minimum
embedment of 3 1/4". Torque was tested with calibrated wrench and was found meeting the 40 ft.
Ib. requirement. All work was completed in conformance with approved plans, manufacturer's
recommendations and ESR #1917.
All racking noted on sheet #1 was inspected at this time.
Distribution:
id Distribute Client Li Distribute Contractor
pj Distribute Engineer : j D• istribute Owner
� 7 Distribute Municipality L✓! D• istribute Other
H Distribute Architect ;] Distribute Other
Inspector: Chandler, Loren
Reviewed by: Michele Guerrini
All reports are considered confidential and are the property of the client and A.A.R. Testing Laboratory, Inc.
Reproduction except in full without the written consent of A.A.R. Testing is strictly forbidden
City of Tukwila
Department of Community Development
November 08, 2016
NICK HOFFMAN
1100 SW 7TH ST
RENTON, WA 98057
RE: Correction Letter # 1
DEVELOPMENT Permit Application Number D16-0288
MOTION INDUSTRIES - 18436 CASCADE AVE S
Dear NICK HOFFMAN,
Allan Ekberg, Mayor
Jack Pace, Director
This letter is to inform you of corrections that must be addressed before your development permit can be approved. All
correction requests from each department must be addressed at the same time and reflected on your drawings. I have
enclosed comments from the following departments:
FIRE DEPARTMENT: Al Metzler at 206-971-8718 if you have questions regarding these comments.
• 1) Please provide a detailed description of the types of commodities to be stored on the racks.
2) Please provide the total storage height and the ceiling height. ,, ,,� jj.,�v
3) What is the sprinkler density of the existing fire sprinkler system? .�� g4 orf Wait( e, J►f%eL'�'"j g co*
4) What is the temperature rating of the existing ceiling sprinklers? ove -00_, fv-
C> (,hr. of SPr/n.Ue' d ,Frain,, (o'—t;/ed 44110 /.f -S-1 ?,5-
Please address the comments above in an itemized format with applicable revised plans, specifications, and/or other
documentation. The City requires that two (2) sets of revised plan pages, specificions and/or other documentation be
resubmitted with the appropriate revision block. Ca4/:L� L i 2
In order to better expedite your resubmittal, a Revision Submittal -Sheet' m accompa y every resubmittal. I have
enclosed one for your convenience. Corrections/revisions must be made in person and will not be accepted through the mail
or by a messenger service.
If you have any questions, I can be reached at 206-431-3655.
Sincerely,
Bill Rambo
Permit Technician
File No. D16-0288
CORRECTION
LTR#
.A4 Til,a‘ax (co 6)
— &ri OfPce.
Gi3" 7/63
42nn c..:._ 1L1.',1 _ T..l,...:r rai G:_ .. nO/o0 _ _
MEM
RECEIVED
CITY OF TUKWILA
NOV 0 8 2016
PERMIT CENTER
NORTHWEST
HANDLING SYSTEMS, I N C.
The Material Handling Experts
1100 SW 7th St
Renton, WA 98057
(425) 255-0500 ph
(425) 228-6946 fax
ATTN: BUILDING DEPARTMENT AND FIRE DEPARTMENT
RACK INFORMATION SUPPLEMENT
SITE ADDRESS: 18436 Cascade Ave South. STE 160. Tukwila, WA.
TENANT NAME: Motion Industries
DATE: October 21, 2016
APPLICANT: Nick Hoffman / 425.902.7222
In answer to Correction Letter #1 provided for Permit application # D16-0288
Fire Department: Al Metzler. 206.971.8718
1. Commodities stored in racks: Bearings, metal parts, small electric motors, gearboxes and
Gearbox components, assorted conveyor and material handling components. Seals, gaskets,
hand tools, hydraulic pumps and components. Small items are stored in cardboard boxes
with minimal packaging material consisting of plastic/bubble wrap and/or paper packaging.
Larger items stored on standard GMA, pallet, 40"W x 48"L.
2. Total Storage Height in selective racking: Top beam at 15' (180"). Maximum pallet height
on top level, 4' (48")
3. Sprinkler Density: .39/5600 Density / Discharge
4. Temperature Rating: White Sprinkler head - 212* fahrenheit
5. Special inspection of anchor bolts will be performed by AAR Testing Lab. PO Box 2523
Redmond, WA 98073. 425-881-5812.
6. Vertical members of storage racks are designed and installed so that failure of one vertical
member will not cause collapse of more than the bay or bays directly supported by that
member.
CORRECTION
RECEIVED
CITY
CITY OF TUKWILA
NOV 0 8 2016
PERMIT CENTER
City of Tukwila
Department of Community Development
November 08, 2016
NICK HOFFMAN
1100 SW 7TH ST
RENTON, WA 98057
RE: Correction Letter # 1
DEVELOPMENT Permit Application Number D16-0288
MOTION INDUSTRIES - 18436 CASCADE AVE S
Dear NICK HOFFMAN,
Allan Ekberg, Mayor
Jack Pace, Director
This letter is to inform you of corrections that must be addressed before your development permit can be approved. All
correction requests from each department must be addressed at the same time and reflected on your drawings. I have
enclosed comments from the following departments:
FIRE DEPARTMENT: Al Metzler at 206-971-8718 if you have questions regarding these comments.
• 1) Please provide a detailed description of the types of commodities to be stored on the .racks.
2) Please provide the total storage height and the ceiling height.
3) What is the sprinkler density of the existing fire sprinkler system?
4) What is the temperature rating of the existing ceiling sprinklers?
Please address the comments above in an itemized format with applicable revised plans, specifications, and/or other
documentation. The City requires that two (2) sets of revised plan pages, specifications and/or other documentation be
resubmitted with the appropriate revision block.
In order to better expedite your resubmittal, a 'Revision Submittal Sheet' must accompany every resubmittal. I have
enclosed one for your convenience. Corrections/revisions must be made in person and will not be accepted through the mail
or by a messenger service.
If you have any questions, I can be reached at 206-431-3655.
Sincerely,
Bill Rambo
Permit Technician
File No. D16-0288
6300 Southcenter Boulevard Suite #100 • Tukwila Washington 98188 • Phone 206-431-3670 • Fax 206-431-3665
PERMIT COORD COPY.
PLAN REVIEW/ROUTING SLIP
PERMIT NUMBER: D16-0288 DATE: 11/08/16
PROJECT NAME: MOTION INDUSTRIES
SITE ADDRESS: 18436 CASCADE AVE S
Original Plan Submittal
X Response to Correction Letter # 1
Revision #
Revision #
before Permit Issued
after Permit Issued
DEPARTMENTS:
Building Division ❑
Public Works ❑
A -t" ASC 11-U04
Fire Prevention Planning Division
Structural
Permit Coordinator n
PRELIMINARY REVIEW:
Not Applicable n
(no approval/review required)
DATE: 11/10/16
Structural Review Required
REVIEWER'S INITIALS: DATE:
APPROVALS OR CORRECTIONS:
Approved
n Approved with Conditions
Corrections Required _ Denied
(corrections entered in Reviews) (ie: Zoning Issues)
DUE DATE: 12/08/16
n
Notation:
REVIEWER'S INITIALS:
DATE:
Permit Center Use Only
CORRECTION LETTER MAILED:
Departments issued corrections: Bldg D Fire ❑ Ping 0 PW 0 Staff Initials:
12/18/2013
?ERMIT CORD COPY
PLAN REVIEW/ROUTING SLIP
PERMIT NUMBER: D16-0288 DATE: 10/26/16
PROJECT NAME: MOTION INDUSTRIES
SITE ADDRESS: 18436 CASCADE AVE S
X Original Plan Submittal
Response to Correction Letter #
Revision #
Deferred #
before Permit Issued
after Permit Issued
DEPARTMENTS:
AT VC,
tiny fr
Building Division
Public Works
At\ Com{
Fire Prevention
Structural
Planning Division
❑ Permit Coordinator
PRELIMINARY REVIEW:
Not Applicable
(no approval/review required)
DATE: 10/27/16
Structural Review Required
REVIEWER'S INITIALS: DATE:
APPROVALS OR CORRECTIONS: DUE DATE: 11/24/16
Approved
Corrections Required
❑ Approved with Conditions ❑
Denied ❑
(corrections entered in. Reviews) (ie: Zoning Issues)
Notation:
REVIEWER'S INITIALS:
DATE:
Permit Center Use Only
CORRECTION LETTER MAILED: 11~ V ' 1
Departments issued corrections: Bldg 0 Fire Ping 0 PW 0 Staff Initials:
12/18/2013
City of Tukwila
Department of Community Development
6300 Southcenter Boulevard, Suite # 100
Tukwila, Washington 98188
Phone: 206-431-3670
Fax: 206-431-3665
Web site: http://www.ci.tuk-wila.wa.us
Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through
the mail, fax, etc.
Date: /I /27/6 6 Plan Check/Permit Number: D 16-0288
❑ Response to Incomplete Letter #
® Response to Correction Letter # 1
❑ Revision # after Permit is Issued
❑ Revision requested by a City Building Inspector or Plans Examiner
Project Name: Motion Industries
Project Address: 18436 Cascade Ave S ,+
222_SContact Person: AJ/C/ / l''T/ O Phone Number: - `14C 9°4 7;222--
Summary
ummary of Revision:
".Flews& 5 »e au facited a to,,r,'
P> 574;04 Se, !
Y
CITY OF TUKWILA
Nov 0 8 2016
Sheet Number(s): PERMIT CENTER
"Cloud" or highlight all areas of revision includin date of revi n
Received at the City of Tukwila Permit Center by:
- Entered in TRAKiT on l (---0-1
\applications\forms-applications on line\revision submittal
Created: 8-13-2004
Revised:
NORTH WEST HANDLING SYS INC
Hoene Espanol Contact
Safety & Health Claims & Insurance
0 Washington State Department of
Labor & Industries
Page 1 of 2
Search L&I
A -Z Index Help NIv L&1
Workplace Rights Trades & Licensing
NORTH WEST HANDLING SYS INC
Owner or tradesperson
Principals
FRANCK, JAMES JEROME, PRESIDENT
KOSTY, CLARK RANDOLPH, TREASURER
THOMAS, KEVIN A
(End: 09/28/2011)
Doing business as
NORTH WEST HANDLING SYS INC
WA UBI No.
600 051 641
1100 SW 7TH ST
RENTON, WA 98055-2939
425-255-0500
KING County
Business type
Corporation
Governing persons
CLARK
R
KOSTY
JAMES J FRANCK;
License
Verify the contractor's active registration / license / certification (depending on trade) and any past violations.
Construction Contractor Active.
Meets current requirements.
License specialties
GENERAL
License no.
NORTHWH275JF
Effective — expiration
04/06/1973-10/09/2017
Bond
Travelers Cas & Surety Co
Bond account no.
815103354822BCM
$12,000.00
Received by L&I Effective date
10/09/2001 10/01/2001
Expiration date
Until Canceled
Insurance
Travelers Indemnity Company Th $1,000,000.00
Policy no.
Y6302C242044TIA16
Received by L&I Effective date
09/30/2016 10/01/2016
Expiration date
10/01/2017
Insurance history
Savings
Help us improve
https://secure.lni.wa.gov/verify/Detail.aspx?UBI=600051641 &LIC=NORTHWH275JF&SAW= 11/22/2016
SHEET NUMBER
24x48
24x48
24x48
24x48
24x48
24x48
24x48
24x48
24x48
24x48
24x48
24x48
24x48
24x48
24x48
24x48
24x48
24x48
24x48
24x48
24x48
24x48
24x48
24x48
24x48
24x48
24x48
24x48
24x48
24x48
24x48
24x48
24x48
24x48
24x48
24x48
24x48
24x48
24x48
24x48
24x48
24x48
24x48
24x48
24x48
24x48
24x48
24x48
24x48
24x48
24x48
24x48
24x48
24x48
1
24x48 II 24x48
24x48
24x48
24x48
24x48
24x48
24x48
24x48 1 24x48
24x48
24x48
24x48
24x48
24x48
24x48
24x48
24x48
24x48
24x48
24x48
24x48
24x48
24x48
24x48
24x48
24x48
24x48
44X120
24x48
24x48
44X120
44X96
44X96
44X96
44X96
44X96
44X96
44X96
44X96
44X9
44X96
44X96
44X96
44X96
44
44X96
44X96
444-6,-` 44X96
44X96
44X96
44X96
44549-6\
44X96
44X96
4'X8' SMOKE/HEAT VENT
t ,.7oLiunical
Liectrical
Vii' lurnbing
Os Piping
of Tukwila
�► ..__;7::!0 DIVISION
44X96
44X96
44X96
44X96
44X96
44X96
44X96
44X96
REVISIONS
No changes shall be mad
of work without prior a
T k .►ila Building 0
NOTE: R avisicns will require a
and may include additional pl.
REVIEWED FOR
CODE COMPLIANCE
APPROVED
PLAN VIEW
SCALE: 1/8" = 1'-0"
44X96
44X96
44X96
44X96
44X96
44X96
44X96
44X96
36x48
36x48
36x48
FILEtt(p-
COPY
Permit No. O) j
Plan review approval is subject to errors and omissions.
Approval of construction documents does not authorize
the violation of any adopted code or ordinance. Receipt
of approved Field Copy a d '41tions is acknowledged:
By:
Date: f/
City of Tukwila
BUILDING DIVISION
RECEIVED
CITY OF TUKWILA
OCT 21 2016
PERMIT CENTER
DRAWING NUMBER
1
TYP
^
,-'•.
1 3/4"
���
3/8
"0
AST
6
,A3
Vell
T5
30/
ti
®
61,
0
®
�i,
7
t
��
1�
0
Imo
i /'
`'
�l
-,:X°.`%
0
•
:�
100
01
rn
4•, 'maLo
y
�/�
,
�,�
I
I
I 00
I
\
�/
r,
�.
I
,
iii
1 fir
G�
,.
/��
$
4-
I
I
I
t=0.06"
----------�
BOTH SIDES TYP. �� \
1 /8 r1.5 \
\
\
\
i )
/ ❑
.
1 /8
(� (�
1/4"o
(1 000
-
SAFETY LOCK
# CAPACITY)
0
to:
H
t1TT
—t
1
1
gza
0 U 0
c:3
1
"
SEC. A—A
,
°...a
,.
:. °' °,
•. o Q . ; ..
..
' .
.°
°
5
\
\a
P °
° .° ° ... •ptl ° ° a•
1/8IF
1 /8 '1.5" / /
/ / /
// ❑
6"
t=3/8" `
•
r
8"
,
/
N
!
2)-1
(2)-1/2"o
3
/2"o ANCHOR BOLTS PER BASE PLATE
1/4" EMB., (SEE NOTE N0. 4)
---- —
a
N
1
i
SEC. B—B
7/16"0 RIVET
ASTM A576-908
' "
HOT—WROUGHT UNS
G10100 GRACE C-1010 t=3/16"
BASE PLATE
DETAIL
BRACING DETAIL
3 PIN CONNECTION 3D
ROW SPACER
4
44
r
1
'
0
4
°
°
p
0
°
°
p
p
°
y
/
pIr
°Q
°00
o0
°
4
4
°
°00
r
Or
r
Q Q
OQ
r
0
00
'1
o
Qp r
Q
°►
°
°
°
n
°
°
p
1
°
p
°
p
p
°
a
0
I
I
I
°
°0
°0
o
°00
°
p
4°
4°
°aQ
►
°
°
°00
0°
°
o
0
0
0
0
0
QQ
Q P
0
Q
0
0
0
0
0
Q 0
0
fl
..
t
. CORDEAEVPICE®OWOP
Nov 18
CIS of
BUILDING
RCE
DLEFIIION
26
Tukwila
DIVISION
GENERAL CONFIGURATION
5
96" 44" 44"
44"
NOTES:
1—DESIGN OF STEEL STORAGE RACKS AS SHOWN BY THESE DRAWINGS
AND CALCULATIONS ARE IN COMPLIANCE WITH THE REQUIREMENTS
OF THE IBC 2012/2015, ASCE/SEI 7-10, ACI 318-11, RMI/ANSI
2—STEEL FOR ALL SHAPES FY=55 KSI. ASTM A1011 GR.55 (EXCEPT
3—NO FIELD WELDING IN THIS PROJECT ALL WELDED CONSTRUCTION
OF THE APPROVED FABRICATOR #01649 (E70XX ELECTRODES)
4—ALL ANCHORS HILTI KB—TZ, ESR -1917
SPECIAL INSPECTION IS REQUIRED
5—CONCRETE SLAB 6" THICK 2500 PSI. SOIL BEARING CAPACITY 1000
6—STORAGE RACK CAPACITY 2500 #/ LEVEL
7—RACK INSTALLATIONS SHALL DISPLAY IN ONE OR MORE CONSPICUOUS
A PERMANENT SIGN OF 50 SQUARE INCHES IN AREA, SHOWING THE
OF THE RACK (2500 #/ LEVEL)
8—STORAGE RACKS SHALL BE INSTALLED WITH A MAXIMUM TOLERANCE
VERTICAL OF 1 /2" IN 10'-0" OF HEIGHT
9—THE CLEAR SPACE BELOW SPRINKLERS SHALL BE A MINIMUM OF
BETWEEN THE TOP OF THE STORAGE AND THE CEILING SPRINKLER
10—STORAGE RACK AREA NOT OPEN TO PUBLIC, EMPLOYEE ACCESS
RECEIVED
CITY OF
OCT
PERMIT
MH 16.1:2012
AS NOTED)
IN THE SHOP
PSF
LOCATIONS
CAPACITY
FROM THE
18 INCHES
DEFLECTOR.
ONLY
TUKWILA
2 1 2016
CENTER
1
1
1
_
1
—
��
—
_
°O�
4-
_i/
`f
C di
4
a
t
\
\N
RCN
Of
{
\
'�
3
\
3
°/
I
t4-
ALL LEVELS
\
/
�t
ocNi
Rd-
\
• t •
�KOx.
81R
�4ti °�. W9G cr9
�r.Q'
412 WEST
BROADWAY, SUITE
#204,
GLENDALE,
CA. 91204
plc
— —.
CO�
'rco
—
. �" �
SCALE: NONE
DRAWN BY: A.KH.
..
r
DATE: 10-20-16
;;►� s385>z .c4.•
k�.� /�o \,
PROJECT: MOTION INDUSTRIES, INC
18436 �„� E s£�UTH, TUKWILA,
98 °8
FRONT VIEW SIDE VIEW
.-� .�
�� �'�
a .► .�.--•
;j �'
j�r ��t
Asa ��
STORAGE RAC��
�illiIYIF$flll.
�}� �7 �t��'
I� � `'�"`'
EXPIRES 12-26-17