Loading...
HomeMy WebLinkAboutPermit D16-0295 - KOTIS DESIGN - STORAGE RACKSKOTIS DESIGN 1167 ANDOVER PARK W D16-0295 Parcel No: Address: City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-438-9350 Web site: http://www.TukwilaWA.eov DEVELOPMENT PERMIT 3523049097 Permit Number: 1167 ANDOVER PARK W Issue Date: Permit Expires On: Project Name: KOTIS DESIGN D16-0295 11/29/2016. 5/28/2017 Owner: Name: Address: Contact Person: Name: Address: Contractor: Name: Address: License No: Lender: Name: Address: ICON OWNER POOL 1 WEST LLC 2 N RIVERSIDE STE 2350 , CHICAGO, WA, 60606 MIKE SORENSON Phone: (206) 818-4488 1100 SW 7TH ST, RENTON, WA, 98057 NORTH WEST HANDLING SYS INC 1100 SW 7TH ST, RENTON, WA, 98055 NORTHWH275JF KOTIS DESIGN 1167 ANDOVER PARK W , TUKWILA, WA, 98188 Phone: (206) 255-0500 Expiration Date: 10/9/2017 DESCRIPTION OF WORK: SUPPLY AND INSTALL NEW SHELVING. PLEASE SEE ATTACHED SUPPLEMENT, DRAWINGS & ENGINEERING FOR COMMODITY DESCRIPTION, BUILDING INFORMATION, SHELVING DETAILS, ETC. Project Valuation: $7,500.00 Type of Fire Protection: Sprinklers: YES Fire Alarm: Type of Construction: VB Electrical Service Provided by: TUKWILA Fees Collected: $424.58 Occupancy per IBC: S-2 Water District: TUKWILA Sewer District: TUKWILA Current Codes adopted by the City of Tukwila: International Building Code Edition: International Residential Code Edition: International Mechanical Code Edition: Uniform Plumbing Code Edition: International Fuel Gas Code: 2015 2015 2015 2015 2015 National Electrical Code: WA Cities Electrical Code: WAC 296-46B: WA State Energy Code: 2014 2014 2014 2015 Public Works Activities: Channelization/Striping: Curb Cut/Access/Sidewalk: Fire Loop Hydrant: Flood Control Zone: Hauling/Oversize Load: Land Altering: Landscape Irrigation: Sanitary Side Sewer: Sewer Main Extension: Storm Drainage: Street Use: Water Main Extension: Water Meter: Volumes: Cut: 0 Fill: 0 Number: 0 No Permit Center Authorized Signature: Date: I I o'/'•"l X/ I hearby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this development permit and agree to the conditions attached to this permit. Signature: Print Name/i'k., Date: 7(7.2--,/760 This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: ***BUILDING PERMIT CONDITIONS*** 2: Work shall be installed in accordance with the approved construction documents, and any changes made during construction that are not in accordance with the approved construction documents shall be resubmitted for approval. 3: All permits, inspection record card and approved construction documents shall be kept at the site of work and shall be open to inspection by the Building Inspector until final inspection approval is granted. 4: All construction shall be done in conformance with the Washington State Building Code and the Washington State Energy Code. 5: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 8: The total number of fire extinguishers required for an ordinary hazard occupancy with Class A fire hazards is calculated at one extinguisher for each 1,500 sq. ft. of area. The extinguisher(s) should be of the "All Purpose" (3A, 40B:C) dry chemical type. Travel distance to any fire extinguisher must be 75' or less. (IFC 906.3) (NFPA 10, 5.4) 6: Portable fire extinguishers, not housed in cabinets, shall be installed on the hangers or brackets supplied. Hangers or brackets shall be securely anchored to the mounting surface in accordance with the manufacturer's installation instructions. Portable fire extinguishers having a gross weight not exceeding 40 pounds (18 kg) shall be installed so that its top is not more than 5 feet (1524 mm) above the floor. Hand- held portable fire extinguishers having a gross weight exceeding 40 pounds (18 kg) shall be installed so that its top is not more than 3.5 feet (1067 mm) above the floor. The clearance between the floor and the bottom of the installed hand-held extinguishers shall not be less than 4 inches (102 mm). (IFC 906.7 and IFC 906.9) 7: Extinguishers shall be located in conspicuous locations where they will be readily accessible and immediately available for use. These locations shall be along normal paths of travel, unless the fire code official determines that the hazard posed indicates the need for placement away from normal paths of travel. (IFC 906.5) 9: Maintain fire extinguisher coverage throughout. 11: Clearance between ignition sources, such as light fixtures, heaters and flame -producing devices, and combustible materials shall be maintained in an approved manner. (IFC 305.1) 12: Storage shall be maintained 2 feet or more below the ceiling in nonsprinklered areas of buildings or a minimum of 18 inches below sprinkler head deflectors in sprinklered areas of buildings. (IFC 315.3.1) 13: Flue spaces shall be provided in accordance with International Fire Code Table 3208.3. Required flue spaces shall be maintained. 10: Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (City Ordinances #2436 and #2437) 14: Any overlooked hazardous condition and/or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. 15: These plans were reviewed by Inspector 511. If you have any questions, please call Tukwila Fire Prevention Bureau at (206)575-4407. PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 1700 BUILDING FINAL** 1400 FIRE FINAL 4046 SI-EPDXY/EXP CONC CITY OF TUKWILA Community Development Department Public Works Department Permit Center 6300 Southcenter Blvd, Suite 100 Tukwila, WA 98188 http://www.TuicwilaWA.gov 4)1SPBuilding Permit No. 04)1S— Project roject No. Date Application Accepted: 10":11-1 Date Application Expires: 1-t-30—) (For office use only) CONSTRUCTION PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **Please Print** SITE LOCATION /. King Co Assessor's Tax No.: 3C°)I 3 0 it)? / Site Address: 11 1)7 � v[r (park V. p I Apr (�j Suite Number: Floor: 1 Tenant Name: k o tf S P A S pii PROPERTY OWNER Name: c vv WA. cou iCe„ er 1- I. -LC Address: f 0 (,RDx ig_ 3 $ %9 c/o 4,14-7Qr4C4 City./6./Ar tt c ci, cAwD te:1. - Zip: b04.0 CONTACT PERSON — person receiving all project communication Name: ,(4 Ike S'O' re.„,co n Address: ( l o p 7 W 74 I 1f City: 7 State: /474 W _4 Zip?g0 7 ^ ^ Fax: Phone:;06 X06 „. ve_ ��1 �(2S's�x.- 01/4 Email: VAS0('i1,r0n a e'1 k) kS' coves GENERAL CONTRACTOR INFORMATION Company Name(vd )0 _ U WQS^I 1404 J f / . RI Address: 1104 ,Sf TW 7 7' E - City: n_ / State: �� Ziptos-7 I n n 'a Phone: gnat s, 0n,,, Fax: ya j-' ?e, (19 16 Contr Reg No.:ivUr /, ,4/ cr75.ee p Date:/0l9 /t / Tukwila Business License No.: FUd _ 6 i. 70v 7 H:\Applications'Forms-Applications On Line'2011 Applicalions\Pertnit Application Revised - 8-9-11.docx Revised: August 2011 bh New Tenant: ❑ Yes lE:No CHITECT OF RECORD Company Name:7� t p ad( ›Si ► h . 63Inwri Engineer Name: / a rt7 D / 4 _ H Compa , ' ame: City:6.(Crt4 State: c44. Zip9 , Phone:glg BYO - (O Fax: 84 d'io -324_3 Architect Name: City: State Address: City: State. Zip: Phone: Fax: Em.' . ENGINEER OF RECORD Company Name:7� t p ad( ›Si ► h . 63Inwri Engineer Name: / a rt7 D / 4 _ H Address: 7ir- iv, vro frai,44::::,,y City:6.(Crt4 State: c44. Zip9 , Phone:glg BYO - (O Fax: 84 d'io -324_3 Email: City: LENDER/BOND ISSUED (required for projects $5,000 or greater per RCW 19.27.095) Name: e/ /' ,,£ l �'t� Address: J-ciA. T $i /ori City: State Zip: Page 1 of 4 BUILDING PERMIT INFORMATION — 206-431-3670 Valuation of Project (contractor's bid price): $ 7 5-0 0 Existing Building Valuation: $ '--- Describe the scope of work (please provide detailed information): J d (c7 4' icS 1I n.2t ' f'a(v' , S Gl.'fkNu fvf ptedne# r Jr wt ,Si yinpt_T'1 COr>7 � 11 ac _// t cAr iticn, � o bultIertnJP, I. o4 cv''1) SiA9-iv11 c41.144;(1- i J2 -IC • Will there be new' ck storage? 12v-' Yes ❑.. No If yes, a separate permit and plan submittal will be required. Provide All Building Areas in Square Footage Below PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Will there be a change in use? ❑ Yes &K -No If "yes", explain: Compact: Handicap: FIRE PROTECTION/HAZARDOUS MATERIALS: l V Sprinklers 0 Automatic Fire Alarm 0 None 0 Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? 0 Yes ®K— No If 'yes', attach list of materials and storage locations on a separate 8-1/2" x 11 "paper including quantities and Material Safety Data Sheets. SEPTIC SYSTEM 6-Axt ❑ On-site Septic System — For on-site septic system, provide 2 copies of a current septic design approved by King County Health Department. H:Wpplications\Forms-Applications On Line \2011 Applications\Permit Application Revised - 8.9-11.docx Revised: August 2011 bh Page 2 of 4 Existing Interior Remodel Addition to Existing Structure New Type of Construction per IBC Type of Occupancy per IBC s< 1 Floor /3r"7. 0).? -06..-& V8 S-- d - 2nd Floor t 3rd Floor Floors thru Basement Accessory Structure* Attached Garage Detached Garage Attached Carport Detached Carport I Covered Deck Uncovered Deck PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Will there be a change in use? ❑ Yes &K -No If "yes", explain: Compact: Handicap: FIRE PROTECTION/HAZARDOUS MATERIALS: l V Sprinklers 0 Automatic Fire Alarm 0 None 0 Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? 0 Yes ®K— No If 'yes', attach list of materials and storage locations on a separate 8-1/2" x 11 "paper including quantities and Material Safety Data Sheets. SEPTIC SYSTEM 6-Axt ❑ On-site Septic System — For on-site septic system, provide 2 copies of a current septic design approved by King County Health Department. H:Wpplications\Forms-Applications On Line \2011 Applications\Permit Application Revised - 8.9-11.docx Revised: August 2011 bh Page 2 of 4 PERMIT APPLICATION NOTES — Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR AUTHO AGENT: Signature: Print Name:./ ; Ke- rem So") Mailing Address: 1100 S UV 71 .7 Date: (0/.6A Day Telephone: 0.106 -81g HAApplications\Fomu-Applications On Line \2011 Applications\Permit Application Revised - 8-9-11.docx Revised: August 2011 bh City State Zip Page 4 of 4 Cash Register Receipt City of Tukwila DESCRIPTIONS ACCOUNT QUANTITY PermitTRAK PAID $424.58 D16-0295 Address: 1167 ANDOVER PARK W Apn: 3523049097 $424.58 DEVELOPMENT $412.22 PERMIT FEE R000.322.100.00.00 0.00 $247.10 PLAN CHECK FEE R000.345.830.00.00 0.00 $160.62 WASHINGTON STATE SURCHARGE 8640.237.114 0.00 $4.50 TECHNOLOGY FEE $12.36 TECHNOLOGY FEE TOTAL FEES PAID BY RECEIPT: R9768 R000.322.900.04.00 0.00 $12.36 $424.58 Date Paid: Monday, October 31, 2016 Paid By: MICHAEL SORENSON Pay Method: CREDIT CARD 09258D Printed: Monday, October 31, 2016 11:20 AM 1 of 1 CSYSTEMS INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3 Permit Inspection Request Line (206) 438-9350 bib ) i'1 Project:T 97s sf JitedA e of Inspection: & / JAL Address:n //67.Awlev dpil w Date Called: Special Instructions: Date Wanted: a.m: S74/1) % p.m. Request. / Keuri--- Phone No: 2t '/l€ /0/2. Approved per applicable codes. ki° LJ Corrections required prior to approval. COMMENTS: aiK - T /h/, -,_ / L--D/N - _ l ns pector: Date: REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. I INSPECTION NUMBER INSPECTION RECORD Retain a copy with permit PERMIT NUMBERS CITY OF TUKWILA FIRE DEPARTMENT 206-575-4407 Project:T i!:07l5 D s(6W - (2'16, pe of Inspection: -c> r112-6"-- -/,--)frz___ Address: t I is Suite #:0 r Contact �rso i Special Instructions: t Phone No.: Approved per applicable codes. Corrections required prior to approval. COMMENTS: Sprinklers: ((ES Hrs.: j Fire Alarm: Hood & Duct: — Monitor: Pre -Fire: NET bE — F (,2 F(/vie- 4 pj2i jv &—T ) —1,V G'\) S? Tr- /y2 p m /^./S77 � C z_ „4 A09/770.1 ' / t- /C/ f - 6-'><-7--/"4 0 She ---?z . Z -01-v1-1(2 E !44 i p 0 LE Q� ,vr p i l 5 Needs Shift Inspection: y6-‘7 Sprinklers: ((ES Hrs.: j Fire Alarm: Hood & Duct: — Monitor: Pre -Fire: NET bE Permits: Occupancy Type: —1,V Inspector: F74 54--- Date: 5/7j/ 2_,_ Hrs.: j $100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. Billing Address Attn: Company Name: Address: City: State: Zip: Word/Inspection Record Form.Doc 3/14/14 T.F.D. Form F.P. 113 Fireproofing Aggregates Shotcrete Concrete Masonry Asphalt Roofing P iling S teel S oils Wood May 1,2017 File No. 17-349 Building Official City of Tukwila Building Department 6300 Southcenter Blvd. Tukwila, WA 98188 Project: Address: Permit: Kotis Design — Building B 1165 Andover Park West D16-0295 A.A.R. TESTING LABORATORY, INC. CONSTRUCTION INSPECTION AND MATERIAL TESTING NATIONALLY ACCEPTED LABORATORY This is to advise you that special inspections are completed on the above referenced project. The following inspection was required and a copy of our inspection report is attached. 1. Proprietary anchor installation To the best of our knowledge all work inspected conformed to Tukwila Building Department approved plans, specifications, IBC and related codes and/or verbal or written instructions from the Engineer of Record. Sincerely, A.A.R. TESTING LABORATORY, INC. Kimberle Anderson President CC: NorthWest Handling Systems, Inc. -Tony Johnson RECEIVED CITY OF TUKWILA MAY 0 1 2017 PERMIT CENTER Tel: (425) 881-5812 Fax (425) 881-5441 • 7126 180th Ave. NE • P.O. Box 2523 • Redmond, WA 98073 Field Report Client: North West Handling System, Inc. 1100 SW 7th Street Renton, WA. Contact: Tony Johnson Report #: 68646 Project Number: Permit #: Project Name: Address: 17-349 016-0295 Kotis Design -BLD B 1165 Andover Park West, Inspection Performed: Proprietary Anchors Date: 4/28/2017 Time: Temperature: Verified anchors to be Hilti KB -TZ 3/8" x 3 1/2" (Bolt D). Verified hole cleanliness and minimum embedment was made or exceeded at 2" . Max torque of 25 ft./lbs. was met. All work was completed in conformance with manufacturer's recommendations, ESR #1917 and approved plans on detail #2 on sheet #2. Location Warehouse floor. RECEIVED CITY OF TUKWILA MAY 0 1 2017 PERMIT CENTER Distribution: pi Distribute Client ❑ D• istribute Contractor ❑ Distribute Engineer ❑ Distribute Owner t Distribute Municipality ❑ Distribute Other ❑ Distribute Architect []f D• istribute Other Inspector: Glass, Shawn Reviewed by: Michele Guerrini All reports are considered confidential and are the property of the client and A.A.R. Testing Laboratory, Inc. Reproduction except in full without the written consent of A.A.R. Testing is strictly forbidden N0RTHWEST HANDLING SYSTEMS, I N C. The Material Handling Experts F r 1100 SW 7th St Renton, WA 98055 (425) 255-0500 ph (425) 228-6946 fax ATTN: BUILDING DEPARTMENT AND FIRE DEPARTMENT SHELVING INFORMATION SUPPLEMENT SITE ADDRESS: 1167 Andover Park W. Bldg. B TENANT NAME: Kotis Design DATE: October 26, 2016 APPLICANT: Mike Sorenson / (206) 818-4488 REVIEWED FOR NODE COMPLIANCE APPROVED NOV 0 9 2016 City of Tukwila BUILDING DIVISION 1. Load application and shelving configuration drawings attached. 2. Attached plans and engineering detail the shelving locations, dimensions, and specifications. 3. Stamped engineering calculations attached. 4. Special inspection of anchor bolts to be performed by AAR Testing Lab. PO Box 2523 Redmond, WA 98073. 5. Commodities stored in shelving: Kotis Designs warehouses and distributes promotional clothing. Shirts, sweatshirts, shorts, etc.... with company logos on them. Cotton and poly clothing stored in cardboard boxes directly on shelves. 6. Sprinkler System Information: .39/5600 with 286 degree heads 7. Building exits with battery backups indicated on attached drawings. %I6- o,g- RECEIVED CITY OF TUKWILA OCT 312016 PERMIT CENTER BY G. OHANIAN RAdK DEOIdN Sc ENdINEERINd do. DATE . 1Q-28-16 412 WEOT BROADWAY, BUITE #204 SUBJECT dLENDALE, CA. 91204 TEL:(818)240-3810 FAX:(818)240-3813 SHEET NO. 1 JOB NO.. RD -18735 STRUCTURAL CALCULATIONS OF STORAGE RACKS FOR: KOTIS DESIGN 1 167 ANDOVER PARK WEST, BLDG. B TUKWILA, WA 98188 PER IBC 2015 SEC. 2209.1 ASCE 7-10 SEC. 15.5.3 RMI/ANSI/MH 16.1:2012 STORAGE RACKS CAPACITY: 200 # / LEVEL CALCS. 1 THRU 3 DRAWINGS: RD -18735 EXPIRES 12-26-17 D I lo- 095 REVIEWED FOR ODE COMPLIANCE APPROVED NOV 092016 City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA OCT 312016 PERMIT CENTER BY G. OHANIAN RAeK DEIGN & ENGINEERING do. DATE. 10-28-16 SUBJECT 412 WEOT BROADWAY, QUITE #204 dLENDALE, CSA. 91204 TEL:(818)240-3810 FAX:(818)240-3813 SHEET NO. 2 JOB NO. RD -18735 CO 72" r 1 CO 10 CO CO \ 1.0 ' BEAM DESIGN SEISMIC DESIGN __ SDS XI V Rx 1 .4 xW SHELVING Sx=.06 FY - = 36K51. 1 36 C 200 # / LEVEL 100 # / BEAM M= 72"x.10 K = .90"K 8 S R= •2°"K = .04<.06 SIDE VIEW IBC 2015 SEC. 2209.1 ASCE 7-10 SEC. 15.5.3, RMI/ANSI/MH 16.1:2012 S Os =0.96 (USGS WEB SITE, "SITE CLASS D") 1=1 NO PUBLIC ACCESS R=6 MOM. CONN. RMI 2.6 AND 2.6.3 W=D.L.+ 3 PALLET LOAD LOAD PER COL. — 5x0.2 KL —0.5 K 2 COL. P=.1 O� (0.5PLx0.75)= .48 K (0.5PLx0.67)= .44 K W-' 1 DL1 V=.05K LONGIT. SEISMIC 020K 014 K 008 K 005 K 003 K 24" .05 K .16"K .27"K .34"K 38"K .40"K 0 .16"K .27"K 34"K .38"K .40"K .15"K BY G. OHANIAN RACK DE$I(4N & ENdINEERIN(c CO. DATE. 10-28-16 SUBJECT 412 WET BROADWAY, OUITE #204 LENDALE, dA. 91204 TEL:(818)240-3810 FAX:(818)240-3813 SHEET NO. 3 JOB NO.. RD -18735 COLUMN DESIGN 1/4" t=.075" x-- -x 3 1/4" 1 COMBINED STRESS RATIO Pex= >r2E.lx = 28 (KL)2 ax=1 Pex .97 Fy=36 Ks1 Ae=.28 x=.07 Smin=•07 rmin=.51 Qc=1.8 QQb=1.67 Cmx=.85 OVERTURNING MOT = .05 Kx2x84"x.66 = 5.5 "K M R = .44 Kx24'= 10.5 "K NO UPLIFT BASE PLATE ANCHOR SHEAR = .05 K KL= 16x1.7=53 min .51 Mn=Se .Fy= 2.5 Qc.P S2b.Cmx.M =.33<1 Pn Mn.ax (1)-3/8"0 ANCHOR PER BASE PLATE, 2" EMB. HILTI KWIK BOLT -TZ ESR -1917 SPECIAL INSPECTION IS REQUIRED MOMENT AT BEAM CONNECTION M _ .40+.38 = 39"K CONN.- 2 V RIVET .25 43.14 x80x.4=1 .5 K Ma = 1.5Kx1.5"=2.3 "K CONN N BEAM - .25"0 RIVET Fy 80 KSI 2 Fe= (KLj2= 102 rx 2 F n=F y(.658 c )=31 KSI Pn=Fn.Ae =8.7 K .44K .44 K 1 1 .05 K .05 K 00 00 24" 4" 0 III 0 COLUMN Ac="/Fy/Fe = .59 Ac<1.5 4/3/2017 City of Tukwila Department of Community Development MIKE SORENSON 1100 SW 7TH ST RENTON, WA 98057 RE: Permit No. D16-0295 KOTIS DESIGN 1167 ANDOVER PARK W Dear Permit Holder: Allan Ekberg, Mayor Jack Pace, Director In reviewing our current records, the above noted permit has not received a final inspection by the City of Tukwila Building Division. Per the International Building Code, International Mechanical Code, Uniform Plumbing Code and/or the National Electric Code, every permit issued by the Building Division under the provisions of these codes shall expire by limitation and become null and void if the building or work authorized by such permit has not begun within 180 days from the issuance date of such permit, or if the building or work authorized by such permit is suspended or abandoned at any time after the work has begun for a period of 180 days. Your permit will expire on 5/28/2017. Based on the above, you are hereby advised to: 1) Call the City of Tukwila Inspection Request Line at 206-438-9350 to schedule for the next or final inspection. Each inspection creates a new 180 day period, provided the inspection shows progress. -or- 2) Submit a written request for permit extension to the Permit Center at least seven(7) days before it is due to expire. Address your extension request to the Building Official and state your reason(s) for the need to extend your permit. The Building Code does allow the Building Official to approve one extension of up to 180 days. If it is determined that your extension request is granted, you will be notified by mail. In the event you do not call for an inspection and/or receive an extension prior to 5/28/2017, your permit will become null and void and any further work on the project will require a new permit and associated fees. Thank you for your cooperation in this matter. Sincerely, Rachelle ' ipl Permit Technician File No: DI6-0295 6300 Southcenter Boulevard Suite #100 • Tukwila, Washington 98188 • Phone 206-431-3670 • Fax 206-431-3665 PERMIT COORD COPY PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: D16-0295 DATE: 10/31/16 PROJECT NAME: KOTIS DESIGN SITE ADDRESS: 1167 ANDOVER PARK W X Original Plan Submittal Revision # before Permit Issued Response to Correction Letter # Revision # after Permit Issued DEPARTMENTS: Building Division Fire Prevention 1147149 Public Works ❑ Structural Planning Division nPermit Coordinator 1 PRELIMINARY REVIEW: Not Applicable ❑ (no approval/review required) DATE: 11/01/16 Structural Review Required REVIEWER'S INITIALS: DATE: n APPROVALS OR CORRECTIONS: Approved ❑ Approved with Conditions Corrections Required Denied (corrections entered in Reviews) (ie: Zoning Issues) DUE DATE: 11/29/16 Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg 0 Fire 0 Ping ❑ PW 0 Staff Initials: 12/18/2013 NORTH WEST HANDLING SYS INT° Home. Espanol Contact Safety & Health Claims & Insurance Washington State Department of Labor & Industries Search L&I A -Z Index Help Page 1 of 2 [.*., My L&I Workplace Rights Trades & Licensing NORTH WEST HANDLING SYS INC Owner or tradesperson Principals FRANCK, JAMES JEROME, PRESIDENT KOSTY, CLARK RANDOLPH, TREASURER THOMAS, KEVIN A (End: 09/28/2011) Doing business as NORTH WEST HANDLING SYS INC WA UBI No. 600 051 641 1100 SW 7TH ST RENTON, WA 98055-2939 425-255-0500 KING County Business type Corporation Governing persons CLARK R KOSTY JAMES J FRANCK; License Verify the contractor's active registration / license / certification (depending on trade) and any past violations. Construction Contractor Active. ......_....._........................................._...... _.... Meets current requirements. License specialties GENERAL License no. NORTHWH275JF Effective — expiration 04/06/1973-10/09/2017 Bond Travelers Cas & Surety Co Bond account no. 81 SI03354822BCM $12,000.00 Received by L&I Effective date 10/09/2001 10/01/2001 Expiration date Until Canceled Insurance .......................... Travelers Indemnity Company Th $1,000,000.00 Policy no. Y6302C242044TIA16 Received by L&I Effective date 09/30/2016 10/01/2016 Expiration date 10/01/2017 Insurance history Help us improve https://secure.lni.wa.gov/verify/Detail.aspx?UBI=600051641&LIC=NORTHWH275JF&SAW= 11/29/2016 KFY INDICATES LOCATION OF "AUG EYE" 3ATTEY BACK UP EXIT LIGHTS/SIG\ - POPOSED SHELVI\G I\ 30X - ALL OTHER SHELVING/ACKING IS EXISTI\G 48X144 48X144 48X144 48X144 48X144 x N 48X144 24x72 I 24 72 I 48X144 24x72 I 24x72 48X144 48X144 24x72 24x72 24x72 I 24x72 36x46 36x48 38x48 38248 8x48 36x48 38x48 36,48 38x48 38,48 8,48 36x46 X 03 38x48 38x48 36x48 38x48 36x46 38x48 36x48 36x48 36x48 38x48 '.8x48 36x48 38x48 38x48 36,48 36x48 N N 338m8x48 36x48 30x48 38x48 38x48 30x48 36,48 36,48 X 03 0 Q 38x72 36x72 36x72 36x72 38,72 38x72 363472 38272 36x72 36x72 36x72 38x72 36x72 38x72 36x72 38x72 X 00 38x72 36x72 38,72 38,872 38x72 38x72 36x72 38x72 36x72 36x72 36x72 36x72 38,72 36x72 36x72 36,72 X 03 38,72 38x72 38x72 36x72 38272 38x72 38,72 38,72 36x72 38,72 38x72 36x72 38x72 38x72 36x72 36x72 X 03 OFFICE EXIT XT 30x69 30x69 30x69 PROPOSED 30x69 30x69 30x69 il 03 X 03 X X 03 38x72 38x72 38272 313x72 36x72 3' 36x72 36,72 38x72 38x72 36x72 3' 38x72 38x72 36x72 38x72 38x72 36,72 3802 36x72 38x72 36x72 36x72 36x72 38272 38,72 38x72 38,72 3802 38,72 3602 36,72 38x72 36x72 38x72 36x72 38x72 36,72 38272 38,72 36x72 38x72 36,72 36x72 36x72 3Sx72 38x72 38x72 3802 36x72 38x72 38x72 38x72 38x72 X 00 F XIT icL=1 PLAN PLAN VIEW NORTI-I SCALE: 3/32" = 1'-0" CO x 0 M (0 0 CD 0 0) (0 0 (0 x O M 0) (0 x 0 M co x O 0) (0 x O 0) (0 x O 6' [72'] 1 6" 4" [18"] 2'-8 [32"] )) 3' —10 [46 "] 5 [60'] ELEVATION 6'-2" [74"] 7' [84'] ti I8r1.�':1 ?ATE EF;MIT l a:QUil ED FOR: � �'achanical [3'Plectrical ciVO tubing latas Piping City of Tukwila BU€i-DNG DIVISION REVISIONS No changes shall be made to the scope of work without prior approval of Tukwila Building Division. NOTE: Ravisio 1s will require a new plan submittal and may include additional plan review fees. I FILE` COPY Permit No. \(P' 0.)—q5— Plan .)—q5Plan review approval is subject to errors and omissions. Approval of construction documents does not authorize the violation of any adopted code or ordinance. Receipt of approved Field Copy and conditions is acknowledged: By: Date: 7/M/1 City of Tukwila BUILDING DIVISION REVIEWED FOR CODE COMPLIANCE APPROVED 1 NOV 09 2016 A-E_., 1 City of Tukwila BUILDING DIVISION Dig RECEIVED CITY OF TUKWILA OCT 312016 PERMIT CENTER SHEET NUMBER DRAWING NUMBER EXPIRES 12-26-1 11°°(? v U U i t t t f l U II 11 ,, *..._____// . r g) I 13 g I� I IU , i ��� , cc .)>,, ,-,7, yi II I III I I (7Jf ( 1 �yf OA. _..._ CI? 4 i/4"0 SCREWS TEK -mac r� .11t- 1 „.. _„,,,,,_, 1 .":1) r0�(I g n . ....--- g f 07 ,,,, 0011 ,..) o 0 0 , n 1) fr 1104. 0 g ✓ P�S1 IN jn YYY 1 ° 4a• I / n + I II Y a) `I/ /��j es Ai. / / n ° °° ' • , J ° • °° a • LER' TO RIGHT FRONT TO BACK I , 11I r ....i - , i • `� i2�0 sr.up #SRS Nr (VA04 3 1 /4" 1 1/2" "T" "L" POST COL. B.PL. 1/4"0 RIVET POST COL. B.PL. T—POST L— POST (1)-3/8"0 ANCHOR BOLT PER BASE PLATE (1)-3/8 ANCHOR BOLT PER BASE PLATE 2" EMB., (SEE NOTE NO. 3) ASTM A576 -90B GA. 14 GA. 14 GA. 2"t=14 EMB., (SEE NOTE NO. 3) POST 1 BASE PLATE DETAIL (2i BEAM CONNECTION El - . b 1 0 Ai 5:0 _ NOTES; 72" 36" 24" 1 -DESIGN OF STEEL STORAGE RACKS AS SHOWN BY THESE DRAWINGS AND CALCULATIONS ARE IN COMPLIANCE WITH THE REQUIREMENTS OF THE IBC 2015, ASCE/SEI 7-10, ACI 318-11, RMI/ANSI MH 16.1:2012 2 -STEEL FOR ALL SHAPES FY=36 KSI. ASTM A1011 GR.36 (EXCEPT AS NOTED) 3 -ALL ANCHORS HILTI KWIK BOLT -TZ ESR -1917 SPECIAL INSPECTION IS REQUIRED 4 -CONCRETE SLAB 6" THICK 2500 PSI. SOIL BEARING CAPACITY 1000 PSF 5 -STORAGE SHELVING CAPACITY 200 #/ LEVEL 6 -SHELVING INSTALLATIONS SHALL DISPLAY IN ONE OR MORE CONSPICUOUS LOCATIONS A PERMANENT SIGN OF 50 SQUARE INCHES IN AREA, SHOWING THE CAPACITY OF THE RACK (200 #/ LEVEL) 7 -STORAGE SHELVING SHALL BE INSTALLED WITH A MAXIMUM TOLERANCE FROM THE VERTICAL OF 1/2" IN 10'-0" OF HEIGHT 8 -THE CLEAR SPACE BELOW SPRINKLERS SHALL BE A MINIMUM OF 18 INCHES BETWEEN THE TOP OF THE STORAGE AND THE CEILING SPRINKLER DEFLECTOR. 19 -STORAGE SHELVING AREA NOT OPEN TO PUBLIC, EMPLOYEE ACCESS ONLY REVIEWED FOR BODE COMPLIANCE APPROVED NOV 0 9 2016 City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA OCT 312016 PERMIT CENTER © 0 © --" �'� r 0 ""��" _"" ' N— d- ° • pNq RACK DESIGN AND ENGINEERING `� .�K ,, CL of wa r 4 w y q 2DRAWN 412 WEST BROADWAY, SUITE #204, GLENDALE, CA. 91204 0 0 cL co �' Wir IMIK C?�v G n tk� '� SCALE: NONE BY: . iy' j DATE: 10-28-16 �^- � r7\ �� 99862 `, kE•:,IST O%' PROJECT: KOT I S DESIGN 1167 ANDOVER PARK WEST, BLDG. B, TUKWILA, WA 98188 40�'}���'C> °" JOB N0. SHEET N0. FRONT VIEW SIDE VIEW ,,{., STORAGE SHELVING DETAILS RD -18735 EXPIRES 12-26-1