Loading...
HomeMy WebLinkAboutPermit D16-0320 - WALSH GROUP - TENANT IMPROVEMENT AND EXPANSIONWALSH GROUP 16400 SOUTHCENTER PKWY 501 EXPIRED 03/06/18 D16-0320 Parcel No: Address: City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-438-9350 Web site: http://www.TukwilaWA.gov DEVELOPMENT PERMIT 2623049021 16400 SOUTHCENTER PKWY 501 Project Name: WALSH GROUP Permit Number: D16-0320 Issue Date: 3/10/2017 Permit Expires On: 9/6/2017 Owner: Name: Address: Contact Person: Name: Address: Contractor: Name: Address: License No: Lender: Name: Address: RADOVICH PROPERTIES LLC 2835 82ND AVE SE STE S 1, MERCER ISLAND, WA, 98040 LINDA DUCEY 1500 WESTLAKE AVE N, SUITE 1, SEATTLE, WA, 98109 Phone: (206) 441-1449 DAVIS SCHUELLER INC Phone: (206) 775-9400 20700 44TH AVE W STE 280, LYNNWOOD, WA, 98036 DAVISSI105PN Expiration Date: 7/1/2018 WALSH GROUP 16400 SOUTHCENTER PKWY - SUITE 501, TUKWILA, WA, 98188 DESCRIPTION OF WORK: INTERIOR TENANT IMPROVEMENTS AND EXPANSION TO ANY EXISTING OFFICE SUITE ON THE FIFTH FLOOR, SUITE 501, FOR OFFICE USE TO INCLUDE DEMOLITION OF DOORS, RELITES, AND PARTITIONS, NEW CONSTRUCTION OF PARTITION, NEW DOORS AND RELITES, EXISTING LIGHTING RELOCATED. NO STRUCTURAL WORK AND NO ALTERATIONS TO THE BUILDING CORE. Project Valuation: $30,000.00 Type of Fire Protection: Sprinklers: YES Fire Alarm: Type of Construction: IIA Electrical Service Provided by: TUKWILA Fees Collected: $1,155.24 Occupancy per IBC: B Water District: TUKWILA Sewer District: TUKWILA Current Codes adopted by the City of Tukwila: International Building Code Edition: International Residential Code Edition: International Mechanical Code Edition: Uniform Plumbing Code Edition: International Fuel Gas Code: 2015 2015 2015 2015 2015 National Electrical Code: WA Cities Electrical Code: WAC 296-46B: WA State Energy Code: 2014 2014 2014 2015 Public Works Activities: Channelization/Striping: Curb Cut/Access/Sidewalk: Fire Loop Hydrant: Flood Control Zone: Hauling/Oversize Load: Land Altering: Landscape Irrigation: Sanitary Side Sewer: Sewer Main Extension: Storm Drainage: Street Use: Water Main Extension: Water Meter: No Volumes: Cut: 0 Fill: 0 Number: 0 Permit Center Authorized Signature: Li La Date: I hearby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this development permit and agree to the conditions attached to this permit. Signature: Print Name: 6:0w1-12Aj tt% Date: `3 // 67('1' This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: ***BUILDING PERMIT CONDITIONS*** 2: Work shall be installed in accordance with the approved construction documents, and any changes made during construction that are not in accordance with the approved construction documents shall be resubmitted for approval. 3: All permits, inspection record card and approved construction documents shall be kept at the site of work and shall be open to inspection by the Building Inspector until final inspection approval is granted. 4: Partition walls shall not be tied to a suspended ceiling grid. All partitions greater than 6 feet in height shall be laterially braced to the building structure. Such bracing shall be independent of any ceiling splay bracing. 5: All construction shall be done in conformance with the Washington State Building Code and the Washington State Energy Code. 6: There shall be no occupancy of a building until final inspection has been completed and approved by Tukwila building inspector. No exception. 7: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 10: The total number of fire extinguishers required for a light hazard occupancy with Class A fire hazards is calculated at one extinguisher for each 3,000 sq. ft. of area. The extinguisher(s) should be of the "all purpose" (2A, 10 B:C) dry chemical type. The travel distance to any extinguisher must be 75' or less. (IFC 906.3) (NFPA 10, 5.4) 8: Portable fire extinguishers, not housed in cabinets, shall be installed on the hangers or brackets supplied. Hangers or brackets shall be securely anchored to the mounting surface in accordance with the manufacturer's installation instructions. Portable fire extinguishers having a gross weight not exceeding 40 pounds (18 kg) shall be installed so that its top is not more than 5 feet (1524 mm) above the floor. Hand- held portable fire extinguishers having a gross weight exceeding 40 pounds (18 kg) shall be installed so that its top is not more than 3.5 feet (1067 mm) above the floor. The clearance between the floor and the bottom of the installed hand-held extinguishers shall not be less than 4 inches (102 mm). (IFC 906.7 and IFC 906.9) 9: Extinguishers shall be located in conspicuous locations where they will be readily accessible and immediately available for use. These locations shall be along normal paths of travel, unless the fire code official determines that the hazard posed indicates the need for placement away from normal paths of travel. (IFC 906.5) 11: Maintain fire extinguisher coverage throughout. 12: Egress doors shall be readily openable from the egress side without the use of a key or special knowledge or effort. (IFC 1008.1.8.3 subsection 2.2) 13: Dead bolts are not allowed on auxiliary exit doors unless the dead bolt is automatically retracted when the door handle is engaged from inside the tenant space. (IFC Chapter 10) 14: Exit hardware and marking shall meet the requirements of the International Fire Code. (IFC Chapter 10) 15: Door handles, pulls, latches, locks and other operating devices on doors required to be accessible by Chapter 11 of the International Building Code shall not require tight grasping, tight pinching or twisting of the wrist to operate. (IFC 1008.1.9.1) 16: Aisles and aisle access ways serving as a portion of the exit access in the means of egress system shall comply with the requirements of this section. Aisles or aisle access ways shall be provided from all occupied portions of the exit access which contain seats, tables, furnishings, displays and similar fixtures or equipment. The required width of aisles shall be unobstructed. (IFC 1017.1) 20: Fire protection systems shall be maintained in accordance with the original installation standards for that system. Required systems shall be extended, altered or augmented as necessary to maintain and continue protection whenever the building is altered, remodeled or added to. Alterations to fire protection systems shall be done in accordance with applicable standards. (IFC 901.4) 18: Sprinklers shall be installed under fixed obstructions over 4 feet (1.2 m) wide. (NFPA 13-8.6.5.3.3) 17: All new sprinkler systems and all modifications to existing sprinkler systems shall have fire department review and approval of drawings prior to installation or modification. New sprinkler systems and all modifications to sprinkler systems involving more than 50 heads shall have the written approval of Factory Mutual or any fire protection engineer licensed by the State of Washington and approved by the Fire Marshal prior to submittal to the Tukwila Fire Prevention Bureau. No sprinkler work shall commence without approved drawings. (City Ordinance No. 2436). 21: A fire alarm system is required for this project. The fire alarm system shall meet the requirements of N.F.P.A. 72 and City Ordinance #2437. 23: Maintain fire alarm system audible/visual notification. Addition/relocation of walls or partitions may require relocation and/or addition of audible/visual notification devices. (City Ordinance #2437) 22: All new fire alarm systems or modifications to existing systems shall have the written approval of The Tukwila Fire Prevention Bureau. No work shall commence until a fire department permit has been obtained. (City Ordinance #2437) (IFC 901.2) 24: An electrical permit from the City of Tukwila Building Department Permit Center (206-431-3670) is required for this project. 25: The maximum flame spread class of finish materials used on interior walls and ceilings shall not exceed that set forth in Table No. 803.9 of the International Building Code. 19: Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (City Ordinances #2436 and #2437) 26: Any overlooked hazardous condition and/or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. 27: These plans were reviewed by Inspector 511. If you have any questions, please call Tukwila Fire Prevention Bureau at (206)575-4407. PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 1700 BUILDING FINAL** 1400 FIRE FINAL 0409 FRAMING 0606 GLAZING 0406 SUSPENDED CEILING CITY OF TUKW1L Community Development Department Public Works Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.TukwilaWA.gov r Building Permit No. DI - LJ 9r0 Project No. Date Application Accepted: 11''-)-1 Date Application Expires: (For office use only) 7 CONSTRUCTION PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **Please Print** SITE LOCATION King Co Assessor's Tax No.: 262304-9021 Site Address: 16400 Southcenter Parkway Tenant Name: Walsh Group Suite Number: 501 Floor: 5th floor PROPERTY OWNER Name: John C. Radovich Development Co. Address: 2385 82nd Ave. SE, suite 300 City: Mercer Island State: WA Zip: 98040 CONTACT PERSON — person receiving all project communication Name: Linda Ducey Address: 1500 Westlake Ave. N. , suite one City: Seattle State: WA Zip: 98109 Phone: (206) 441-1449 Fax: Email: 1.ducey@marvinstein.com GENERAL CONTRACTOR INFORMATION Company Name: TBD Address: Address: 1500 Westlake Ave. N. , suite one City: Seattle State: WA zip: 98109 Phone: (206) 441-1449 Fax: City: State: City: l I qt/AIk+k\Lf'C Zip: Phone: Fax: City: State: Contr Reg No.: Phone: Exp Date: Tukwila Business License No.: H:Wpplications\Forms-Applications On Line \2011 Applications\Permit Application Revised - 8-9-11.docx Revised: August 2011 bh New Tenant: ❑ Yes 121 ..No ARCHITECT OF RECORD Company Name: Marvin Stein Associates Architect Name: Mark Evans Address: 1500 Westlake Ave. N. , suite one City: Seattle State: WA zip: 98109 Phone: (206) 441-1449 Fax: Email: m.evans@marvinstein.com ENGINEER OF RECORD Name: ���;U �, f�p C Company Name: Address: i/-UDx`' / Engineer Name: City: l I qt/AIk+k\Lf'C Address: Zip:00 City: State: Zip: Phone: Fax: Email: LENDER/BOND ISSUED (required for projects $5,000 or greater per RCW 19.27.095) Name: ���;U �, f�p C rN Address: i/-UDx`' / , City: l I qt/AIk+k\Lf'C State:( Zip:00 Page 1 of 4 i BUILDING PERMIT INFORMATIOI 06-431-3670 Valuation of Project (contractor's bid price): $ 30,000 Existing Building Valuation: $ Describe the scope of work (please provide detailed information): Interior tenant improvements and expansion to any existing office suite on the fifth floor, suite #501, for office use to include demolition of doors, relites, and partitions, new construction of partition, new doors and relites, existing lighting relocated. No structural work and no alterations to the building core. Will there be new rack storage? 1=1 Yes .. No If yes, a separate permit and plan submittal will be required. Provide All Building Areas in Square Footage Below PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): 84,975 Floor area of principal dwelling: 64,725 Floor area of accessory dwelling: 0 *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact: Handicap: Will there be a change in use? 0 Yes ((] No If "yes", explain: FIRE PROTECTION/HAZARDOUS MATERIALS: ® Sprinklers 0 Automatic Fire Alarm 0 None 0 Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? 0 Yes 171 No If `yes', attach list of materials and storage locations on a separate 8-1/2" x 11" paper including quantities and Material Safety Data Sheets. SEPTIC SYSTEM 0 On-site Septic System — For on-site septic system, provide 2 copies of a current septic design approved by King County Health Department. H:\Applications\Forms-Applications On Line\2011 Applications\Permit Application Revised - 8-9-11.docx Revised: August 2011 bh Page 2 of 4 Existing Interior Remodel Addition to Existing Structure New Type of Construction per IBC Type of Occupancy per IBC 1" Floor 0 2"d Floor 0 3rd Floor 0 Floors 5 thru 13,700 3,900 0 0 II -A sprinkler B -Office Basement 0 Accessory Structure* 0 Attached Garage 0 Detached Garage 0 Attached Carport 0 Detached Carport 0 Covered Deck 0 Uncovered Deck 0 PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): 84,975 Floor area of principal dwelling: 64,725 Floor area of accessory dwelling: 0 *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact: Handicap: Will there be a change in use? 0 Yes ((] No If "yes", explain: FIRE PROTECTION/HAZARDOUS MATERIALS: ® Sprinklers 0 Automatic Fire Alarm 0 None 0 Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? 0 Yes 171 No If `yes', attach list of materials and storage locations on a separate 8-1/2" x 11" paper including quantities and Material Safety Data Sheets. SEPTIC SYSTEM 0 On-site Septic System — For on-site septic system, provide 2 copies of a current septic design approved by King County Health Department. H:\Applications\Forms-Applications On Line\2011 Applications\Permit Application Revised - 8-9-11.docx Revised: August 2011 bh Page 2 of 4 PUBLIC WORKS PERMIT INFO' kTION — 206-433-0179 Scope of Work (please provide detailed information): N/A Call before you Dig: 811 Please refer to Public Works Bulletin #1 for fees and estimate sheet. Water District ❑ ...Tukwila ❑... Water District #125 ❑ ...Water Availability Provided Sewer District ❑ ...Tukwila ❑ ...Sewer Use Certificate ❑...Valley View ❑ ... Sewer Availability Provided ❑ .. Highline ❑ .. Renton ❑ .. Renton ❑ .. Seattle Septic System: ❑ On-site Septic System — For on-site septic system, provide 2 copies of a current septic design approved by King County Health Department. Submitted with Application (mark boxes which apply): ❑ ...Civil Plans (Maximum Paper Size — 22" x 34") ❑ ...Technical Information Report (Storm Drainage) ❑ ...Bond 0 .. Insurance 0 .. Easement(s) Proposed Activities (mark boxes that apply): ❑ ...Right-of-way Use - Nonprofit for less than 72 hours ❑ ...Right-of-way Use - No Disturbance ❑ ...Construction/Excavation/Fill - Right-of-way 0 Non Right-of-way 0 ❑ ...Total Cut ❑ ...Total Fill cubic yards cubic yards ❑ ...Sanitary Side Sewer ❑ ...Cap or Remove Utilities ❑ ...Frontage Improvements ❑ ...Traffic Control ❑ ...Backflow Prevention - Fire Protection Irrigation Domestic Water ❑ .. Geotechnical Report ❑ .. Maintenance Agreement(s) ❑ ...Traffic Impact Analysis ❑ ...Hold Harmless — (SAO) ❑ ...Hold Harmless — (ROW) ❑ .. Right-of-way Use - Profit for less than 72 hours ❑ .. Right-of-way Use — Potential Disturbance ❑ .. Work in Flood Zone ❑ .. Storm Drainage ❑ .. Abandon Septic Tank ❑ .. Curb Cut 0 .. Pavement Cut ❑ .. Looped Fire Line ❑ ...Permanent Water Meter Size... ❑ ...Temporary Water Meter Size .. ❑ ...Water Only Meter Size ❑ ...Sewer Main Extension Public ❑ ...Water Main Extension Public WO # WO # WO # Private 0 Private 0 ❑ .. Grease Interceptor ❑ .. Channelization ❑ .. Trench Excavation ❑ .. Utility Undergrounding 0 ...Deduct Water Meter Size If FINANCE INFORMATION Fire Line Size at Property Line 0 ...Water 0 ...Sewer 0 ...Sewage Treatment Monthly Service Billing to: Name: Number of Public Fire Hydrant(s) Day Telephone: Mailing Address: City State Zip Water Meter Refund/Billing: Name: Mailing Address: Day Telephone: City State Zip H:\ Applications\Forms-Applications On Line \2011 Applications\Permit Application Revised - 8-9-11.docx Revised: August 2011 bh Page 3 of 4 PERMIT APPLICATION NOTES — Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR AUTHO Signature: ateer---2 Print Name: Linda Ducey Mailing Address: 1500 Westlake Ave. N. H: Applications\Forms-Applications On Line \2011 Applications\Permit Application Revised - 8-9-11.docx Revised: August2011 bh Date: 11/21/2016 Day Telephone: (206) 441-1449 Seattle WA 98109 City State Zip Page 4 of 4 Cash Register Receipt City of Tukwila DESCRIPTIONS ACCOUNT QUANTITY PermitTRAK PAID $715.25 D16-0320 Address: 16400 SOUTHCENTER PKWY 501 Apn: 2623049021 $715.25 DEVELOPMENT $681.40 PERMIT FEE R000.322.100.00.00 0.00 $676.90 WASHINGTON STATE SURCHARGE B640.237.114 0.00 $4.50 TECHNOLOGY FEE $33.85 TECHNOLOGY FEE TOTAL FEES PAID BY RECEIPT: R11059 R000.322.900.04.00 0.00 $33.85 $715.25 Date Paid: Friday, March 10, 2017 Paid By: WALSH CONSTRUCTION COMPANY Pay Method: CHECK 166363 Printed: Friday, March 10, 2017 1:34 PM 1 of 1 CSYSTEMS Cash Register Receipt City of Tukwila DESCRIPTIONS ACCOUNT QUANTITY PAID PermitTRAK $439.99 D16-0320 Address: 16400 SOUTHCENTER PKWY 501 Apn: 2623049021 $439.99 DEVELOPMENT $439.99 PLAN CHECK FEE TOTAL FEES PAID BY RECEIPT: R9897 R000.345.830.00.00 0.00 $439.99 $439.99 Date Paid: Monday, November 21, 2016 Paid By: NELSON WORLDWIDE INC Pay Method: CHECK 230 Printed: Monday, November 21, 2016 3:33 PM 1 of 1 C( SYSTEMS 2/1/2018 City of Tukwila Department of Community Development LINDA DUCEY 1500 WESTLAKE AVE N, SUITE 1 SEATTLE, WA 98109 RE: Permit No. D16-0320 WALSH GROUP 16400 SOUTHCENTER PKWY - SUITE 501 Dear Permit Holder: Allan Ekberg, Mayor Jack Pace, Director In reviewing our current records, the above noted permit has not received a final inspection by the City of Tukwila Building Division. Per the International Building Code, International Mechanical Code, Uniform Plumbing Code and/or the National Electric Code, every permit issued by the Building Division under the provisions of these codes shall expire by limitation and become null and void if the building or work authorized by such permit has not begun within 180 days from the issuance date of such permit, or if the building or work authorized by such permit is suspended or abandoned at any time after the work has begun for a period of 180 days. Your permit will expire on 3/6/2018. Based on the above, you are hereby advised to: 1) Call the City of Tukwila Inspection Request Line at 206-438-9350 to schedule for the next or final inspection. Each inspection creates a new 180 day period, provided the inspection shows progress. -or- 2) Submit a written request for permit extension to the Permit Center at least seven(7) days before it is due to expire. Address your extension request to the Building Official and state your reason(s) for the need to extend your permit. The Building Code does allow the Building Official to approve one extension of up to 180 days. If it is determined that your extension request is granted, you will be notified by mail. In the event you do not call for an inspection and/or receive an extension prior to 3/6/2018, your permit will become null and void and any further work on the project will require a new permit and associated fees. Thank you for your cooperation in this matter. Sincerely, achelle Ripley Permit Technicia File No: D16-0320 6300 Southcenter Boulevard Suite #100 • Tukwila, Washington 98188 • Phone 206-431-3670 • Fax 206-431-3665 PERMIT EXTENSION REQUEST City of Tukwila C/O Building Official 6300 Southcenter Blvd Tukwila, WA 98188 09/05/2017 This letter is to request an extension of tenant improvement permit # D16- 0320 for a period of 60 days. This permit is for work at: 16400 Southcenter Parkway #501 Seattle, WA 98188 The majority of the work under this permit has been completed, however there are a few outstanding items that will need to be completed by the electrician so we can schedule and complete the necessary inspections prior to the expiration of this permit. Please don't hesitate to call or email with any questions or concerns. Regards, Eric VanHemert Request for Extension # i Current Expiration Date: Extension Request: Approved for Denied (provide explanation 15 t/ days Signature/Initials Walsh Group 16400 Southcenter Pkwy, Suite 501 Seattle, WA 98188 P: (206) 394-7300 F: (206) 394-7399 Equal Opportunity Employer RECEIVED CITY OF TUKWILA SEP 0 6 2017 PERMIT CENTER City of Tukwila Allan Ekberg, Mayor Department of Community Development - Jack Pace, Director August 15, 2017 Walsh Group Eric VanHemert 16400 Southcenter Pkwy — Suite 501 Tukwila, WA 98188 RE: Request for Extension #1 Permit Number D16-0320 Dear Mr. VanHemert, This letter is in response to your written request for an extension to Permit D16-0320. The Building Official, Jerry Hight, has reviewed your letter and considered your request to extend the above referenced permit. It has been determined that the City of Tukwila Building Division will be granting an extension to the permit through March 6, 2018. If you should have any questions, please contact our office at (206) 431-3670. Sincerely, Bill Rambo Permit Technician File: Permit No. D16-0320 Tukwila City Hall • 6200 Southcenter Boulevard • Tukwila, WA 98188 • 206-433-1800 • Website: TukwilaWA.gov 8/1/2017 City of Tukwila Department of Community Development LINDA DUCEY 1500 WESTLAKE AVE N, SUITE 1 SEATTLE, WA 98109 RE: Permit No. D16-0320 WALSH GROUP 16400 SOUTHCENTER PKWY - SUITE 501 Dear Permit Holder: Allan Ekberg, Mayor Jack Pace, Director In reviewing our current records, the above noted permit has not received a final inspection by the City of Tukwila Building Division. Per the International Building Code, International Mechanical Code, Uniform Plumbing Code and/or the National Electric Code, every permit issued by the Building Division under the provisions of these codes shall expire by limitation and become null and void if the building or work authorized by such permit has not begun within 180 days from the issuance date of such permit, or if the building or work authorized by such permit is suspended or abandoned at any time after the work has begun for a period of 180 days. Your permit will expire on 9/6/2017. Based on the above, you are hereby advised to: 1) Call the City of Tukwila Inspection Request Line at 206-438-9350 to schedule for the next or final inspection. Each inspection creates a new 180 day period, provided the inspection shows progress. -or- 2) Submit a written request for permit extension to the Permit Center at least seven(7) days before it is due to expire. Address your extension request to the Building Official and state your reason(s) for the need to extend your permit. The Building Code does allow the Building Official to approve one extension of up to 180 days. If it is determined that your extension request is granted, you will be notified by mail. In the event you do not call for an inspection and/or receive an extension prior to 9/6/2017, your permit will become null and void and any further work on the project will require a new permit and associated fees. Thank you for your cooperation in this matter. Sincerely, ach lle Ripley Permit Techmcia File No: DI6-0320 6300 Southcenter Boulevard Suite #100 • Tukwila, Washington 98188 • Phone 206-431-3670 • Fax 206-431-3665 o)ERMIT COORD COPY` PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: D16-0320 PROJECT NAME: WALSH GROUP SITE ADDRESS: 16400 SOUTHCENTER PKWY — SUITE 501 DATE: 11/21/16 X Original Plan Submittal Response to Correction Letter # Revision # before Permit Issued Revision # after Permit Issued DEPARTMENTS: VFV- \LOC tWini Building Division gp 1V,2 4\a` Public Works A -r1 Arc, 1)-4a(0 Fire Prevention Structural gie Planning Division Et ❑ Permit Coordinator PRELIMINARY REVIEW: Not Applicable (no approval/review required) REVIEWER'S INITIALS: DATE: 11/22/16 Structural Review Required DATE: APPROVALS OR CORRECTIONS: Approved ❑ Approved with Conditions Corrections Required (corrections entered in Reviews) Denied (ie: Zoning Issues) DUE DATE: 12/20/16 Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg 0 Fire 0 Ping 0 PW ❑ Staff Initials: 12/18/2013 DAVIS SCHUELLER INC Home Espaiiol Contact Safety & Health Claims & Insurance Washington State Department of Labor & Industries Search L&I Page 1 of 3 A -Z Index help My L&I Workplace Rights Trades & Licensing DAVIS SCHUELLER INC Owner or tradesperson Principals SCHUELLER, KENNETH E, PRESIDENT STOCKBURGER, JAMES A, VICE PRESIDENT SCHUELLER, DANETTE, SECRETARY SCHUELLER, KENNETH E, TREASURER DAVIS, BILL E, PRESIDENT (End: 06/26/2014) SCHUELLER, KENNETH E, VICE PRESIDENT (End: 06/26/2014) DAVIS, BARBARA D, TREASURER (End: 06/26/2014) Doing business as DAVIS SCHUELLER INC WA UBI No. 601 273 797 4601 Chennault Beach Rd Suite 200 MUKILTEO, WA 98275 425-775-9400 SNOHOMISH County Business type Corporation Governing persons BARBARA DAVIS BILL E DAVIS; DANNETTE SCHULLER; KEN SCHUELLER; License Verify the contractor's active registration / license / certification (depending on trade) and any past violations. Construction Contractor Active. Meets current requirements. License specialties GENERAL License no. DAVISSI105PN Effective — expiration 10/15/1990— 07/01/2018 Bond .............. CBIC Bond account no. SF2518 $12,000.00 Received by L&I Effective date 10/31/2003 10/15/2003 Expiration date Until Canceled Help us improve https://secure.lni.wa.gov/verify/Detail.aspx?UBI=601273797&LIC=DAVISSI105PN&SAW= 3/10/2017 DAVIS SCHUELLER INC Insurance .............................. BITCO National Ins Co Policy no. CLP3639915 $1,000,000.00 Received by L&I Effective date 06/28/2016 07/01/2016 Expiration date 07/01/2017 AMCO Ins Co $1,000,000.00 Policy no. ACPGLA03026636708 Received by L&I Effective date 06/22/2016 07/01/2016 Expiration date 07/01/2017 Insurance history Savings ....................... No savings accounts during the previous 6 year period. Lawsuits against the bond or savings ...._......................................................................._................................... No lawsuits against the bond or savings accounts during the previous 6 year period. L&I Tax debts No L&I tax debts are recorded for this contractor license during the previous 6 year period, but some debts may be recorded by other agencies. License Violations ..... ................................................. No license violations during the previous 6 year period. Workers' comp Do you know if the business has employees? If so, verify the business is up-to-date on workers' comp premiums. L&I Account ID 588,421-00 Account is current. DAVIS SCHUELLER INC Estimated workers reported Quarter 4 of Year 2016 "51 to 75 Workers" L&I account representative T1 / DESTINY ADAMS (360)902-4873 - Email: ADAF235@Ini.wa.gov Workplace safety and health Check for any past safety and health violations found on jobsites this business was responsible for. Inspection results date 11/10/2015 Inspection no. 317938271 Location 3600 15th avenue Seattle, WA 98114 Inspection results date 04/02/2014 Inspection no. 316973973 Location 12856 Gateway Dr Tukwila, WA 98168 Violations Violations Page 2 of 3 Washington State Dept. of Labor & Industries. Use of this site is subject to the laws of the state of Washington. Help us improve https://secure.lni.wa.gov/verify/Detail.aspx?UBI=601273797&LIC=DAVISSI105PN&SAW= 3/10/2017 WGE—CV-05.dwg i c 0 0 • 0 0 0 cD _c 0 0 0 Cr) a)L.n o °o oQ I a - I U v) CDS oa N &� I E,io CD cLr- = (t) cC II�N cb O 431 Eooa) i7. cn o x s, \ <<cr,/1/ • J 1/Pti • Cs SOUTHCENTER PLACE EXISTING 5 -STORY OFFICE BUILDING NO CHANGE IN BUILDING AREA NO CORE / SHELL WORK NO STRUCTURAL WORK NO EXTERIOR WORK NO CHANGE OF USE OCCUPANT LOAD & EXITING: PER IBC TABLE 1004.1.2: BUSINESS AREA =100 SF PER OCCUPANT PER IBC TABLE 1015.1: 0-49 OCCUPANT LOAD = ONE (1) EXIT REQUIRED 50-500 OCCUPANT LOAD = TWO (2) EXITS REQUIRED 9,650 SF @ 1:100 = 97 OCCUPANTS 2 EXITS REQUIRED, 4 EXITS PROVIDED PROJECT COMPLIES COMMON PATH OF EGRESS TRAVEL: PER IBC 1014.3: MAX. LENGTH =100'-0" FOR BUILDINGS WITH SPRINKLER SYSTEM LONGEST COMMON PATH OF EGRESS TRAVEL = ± 37' PROJECT COMPLIES AREA OF WORK (± 3,900 SF) POINT WHERE 2 PATHS TO SEPARATE EXITS ARE AVAILABLE, TYP. COMMON AND CORE AREAS, (N.I.C., TYP.) EXIT ACCESS TRAVEL DISTANCE: PER IBC TABLE 1016.2: MAX. DISTANCE = 300'-0" FOR GROUP 'B' OCCUPANCY IN BUILDINGS WITH SPRINKLER SYSTEM PROJECT COMPLIES. NORTH l 509 SEA -TAC INTERNATIONAL AIRPORT SOUTHCENTER PLACE 01.1" NORTH 2 I VICINITY MAP NTS 36 >- Y ct w 1- w U 1- 0 0) STRANDER BLVD � 238 (Am n -rim 11 1111 36 WHIM 11111111/ SOUTHCENTER PLACE 16400 SOUTHCENTER PARKWAY TUKWILA, WA 98188 F 2 7 - OUTBACK STEAK HOUSE NORTH 1 EXITING PLAN AND OCCUPANCY LOAD CALCULATION 1/16" =1'-0" 3 SITE PLAN 1" = 80'-0" EXISTING STRUCTURE METAL CLIP METAL STUDS STAGGERED @ 8'-0" O.C. FOR ALL UNBRACED STRAIGHT RUNS OF WALL OVER 12'-0". ATTACH TO STRUCTURE ABOVE. (2) #10 SCREWS SCHEDULED CEILING TILE & GRID 8'MAX 8'MAX 8'MAX 8'MAX 8'MAX 8'MAX 1 �`z OMIT BRACING AT WALL LATERAL BRACING (STAGGERED) PER DETAIL ABOVE (TYP.) LATERAL WALL BRACING PLAN VIEW NTS i 2' MAX TO END OF WALL TOP OF WALL NOTES: 1. LATERAL BRACING IS TO BE INSTALLED ON TENANT PARTITIONS AT 8 FEET O.C. EXCEPT AT INTERSECTIONS WITH WALLS AT LEAST 4 FEET LONG. (PER TYPICAL PARTITION PLAN) 2. PROVIDE BRACING AT ANY PERMANENT PARTITION THAT IS NOT ATTACHED TO CEILING GRID. 4 STANDARD HEAD BRACING 1-1/2" =1'-0" ACT ACOUSTICAL CEILING TILE ADJ ADJACENT / ADJUSTABLE AFF ABOVE FINISH FLOOR ALT ALTERNATE ALUM ALUMINUM APPROX APPROXIMATELY BLDG BLKG B/S CAB CLR CLG CL COL COMM COMP CONST CONT CPT CT DIA DR DIM DW DWG E EA ELEC ELEC'L ELEV EQ EXIST EXT FIN FLR FLUOR FMC FR AT BUILDING BLOCKING BUILDING STANDARD CABINET CLEAR/CLEARANCE CEILING CENTERLINE COLUMN COMMUNICATION COMPOSITION CONSTRUCTION CONTINUOUS CARPET CERAMIC/CONCRETE TILE DIAMETER DOOR DIMENSION DISHWASHER DRAWING EXISTING / EAST EACH ELECTRIC ELECTRICAL ELEVATION (VIEW) EQUAL EXISTING EXTERIOR FINISH FLOOR FLUORESCENT FLOOR MATERIAL CHANGE FIRE RATED FT FURN GA GALV GD GL GWB HC HDW HM HT HVAC IN INCL INSUL INT JT LL@TE LF MAX MECH MFR MIN MISC MSA MTD MTL MW N N/A NIC NO NOM NTS OC OPNG OPP 5 ABBREVIATIONS FEET FURNISH / FURNISHINGS GAUGE GALVANIZED GARBAGE DISPOSAL GLASS / GLAZING GYPSUM WALL BOARD HOLLOW CORE HARDWARE HOLLOW METAL HEIGHT HEATING, VENTILATING, AIR CONDITIONING INCH INCLUDE INSULATION INTERIOR JOINT BY LANDLORD AT TENANT'S EXPENSE LINEAL FOOT MAXIMUM MECHANICAL MANUFACTURER MINIMUM MISCELLANEOUS MARVIN STEIN ASSOCIATES MOUNTED METAL MICROWAVE OVEN NORTH / NEW NOT APPLICABLE NOT IN CONTRACT NUMBER NOMINAL NOT TO SCALE ON CENTER OPENING OPPOSITE ORIG PERM PL PLAM PLYWD PR PTN R RB REF REFL'D REINF REQ'D REV RM RO S SCHED SC SECT SIM SPEC SQ STD STL STOR SUSP TEL TSG TYP UNO VCT VERT W W/ W/O WC WD ORIGINAL PERMANENT PLATE PLASTIC LAMINATE PLYWOOD PAIR PARTITION RADIUS / REMOVE / RELOCATE RUBBER BASE REFRIGERATOR REFLECTED REINFORCING REQUIRED REVISION / REVERSE ROOM ROUGH OPENING SOUTH SCHEDULE SOLID CORE SECTION SIMILAR SPECIFICATION SQUARE STANDARD STEEL STORAGE SUSPENDED TELEPHONE TEMPERED SAFETY GLASS TYPICAL UNLESS NOTED OTHERWISE VINYL COMPOSITE TILE VERTICAL WEST WITH WITHOUT WALLCOVERING WOOD 1/4" NON-COMBUSTABLE WOOD FILLER UNDER MAIN RUNNERS. EXISTING CEILING CONTINUOUS 'L' METAL TRIM W/ PAPER WING (BOTH SIDES OF PARTITION) GALV. STEEL SILL TRACK. ATTACH TO STRUCTURE WITH HILTI X -U (OR XU15) UNIVERSAL KNURLED SHANK POWER DRIVEN FASTENER WITH MIN. 1" EMBEDMENT @ 16" O.C. (FOLLOW MANUFACTURER'S INSTRUCTIONS). FLOORING AS SCHEDULED (BOTH SIDES OF PARTITION) STUD SCHEDULE STUD SCHEDULE: 2-112" = 250S125-27 (22 GA); MAX 10'-0" HIGH. 3-5/8" = 362S125-27 (22 GA); MAX 13'-0" HIGH. 6" = 600S125-27 (22 GA); MAX 17'-6" HIGH. NOTES: 1. ALL STUDS ARE AT 16" O.C. 2. USE SAME GAUGE AS STUDS FOR TRACKS AND CHANNEL. 3. USE SSMA TECHNICAL GUIDES. STANDARD TENANT PARTITION SEISMIC BRACING (BEYOND) PER 41TI-1. 1/8" BLACK FOAM TAPE, HOLD BACK 1/4" FROM EDGE OF TRACK (BOTH SIDES) METAL TRACK WITH (2) #10 SCREWS AT 16" O.C. REVEAL (PAINT BLACK) OR MATCH EXISTING CONDITION. (BOTH SIDES OF PARTITION) 5/8" FIRE RETARDANT TREATED PLYWOOD BLOCKING AT WALL HUNG ITEMS (WHERE APPLICABLE- REFER TO DRAWING PLANS). ALTERNATE FOR BLOCKING: 20" WIDE SHEET METAL AT +40" FROM FLOOR TO BOTTOM (IN LIEU OF WOOD BLOCKING) 5/8" GWB, TYPE 'X' EACH SIDE BASE, AS SCHEDULED. (BOTH SIDES OF PARTITION.) EXISTING STRUCTURE (BELOW) GALV STEEL STUD, PER STUD SCHEDULE, WITH 5/8" TYPE 'X' GWB EACH SIDE. SEPARATE 'ATE PERMIT i :QUIRED FOR: C%'iJ1echanni lrkElectri C.l'Plumb'abl as ii, of Tukwila P"^.'G DIVISION 1-1/2" =1'-0" 4'-0" WIDE ACOUSTIC BATT INSULATION CENTERED OVER PARTITION ABOVE HUNG CEILING. 1/4" NON-COMBUSTABLE WOOD FILLER UNDER MAIN RUNNERS. EXISTING CEILING CONTINUOUS 'L' METAL TRIM W/ PAPER WING (BOTH SIDES OF PARTITION) ACOUSTIC BATT INSULATION GALV. STEEL SILL TRACK. ATTACH TO STRUCTURE WITH HILTI X -U (OR XU15) UNIVERSAL KNURLED SHANK POWER DRIVEN FASTENER WITH MIN. 1" EMBEDMENT @ 16" O.C. (FOLLOW MANUFACTURER'S INSTRUCTIONS). FLOORING AS SCHEDULED (BOTH SIDES OF PARTITION) STUD SCHEDULE STUD SCHEDULE: 2-1/2" = 250S125-27 (22 GA); MAX 10'-0" HIGH. 3-5/8" = 362S125-27 (22 GA); MAX 13'-0" HIGH. 6" = 600S125-27 (22 GA); MAX 17'-6" HIGH. NOTES: 1. ALL STUDS ARE AT 16" 0.0. 2. USE SAME GAUGE AS STUDS FOR TRACKS AND CHANNEL. 3. USE SSMA TECHNICAL GUIDES. SEISMIC BRACING (BEYOND) PER 4/TI-1. 1/8" BLACK FOAM TAPE, HOLD BACK 1/4" FROM EDGE OF TRACK (BOTH SIDES) METAL TRACK WITH (2) #10 SCREWS AT 16" 0.0. REVEAL (PAINT BLACK) OR MATCH EXISTING CONDITION. (BOTH SIDES OF PARTITION) 5/8" FIRE RETARDANT TREATED PLYWOOD BLOCKING AT WALL HUNG ITEMS (WHERE APPLICABLE- REFER TO DRAWING PLANS). ALTERNATE FOR BLOCKING: 20" WIDE SHEET METAL AT+40" FROM FLOOR TO BOTTOM (IN LIEU OF WOOD BLOCKING) 5/8" GWB, TYPE 'X' EACH SIDE BASE, AS SCHEDULED. (BOTH SIDES OF PARTITION.) EXISTING STRUCTURE (BELOW) GALV STEEL STUD, PER STUD SCHEDULE, WITH 5/8" TYPE 'X' GWB EACH SIDE. REVISrON@ No changes shall h e to the scope of work without prior approval of T-ulr,^-,;!a Building Division. IROTE: Ficvisions will require a new plan submittal I and may include additional plan review fees. J 7 1 STD TENANT DEMISING SOUND PARTITION 1-1/2"=1'-0° PROJECT INFORMATION SCOPE OF WORK: CONSTRUCTION TYPE: OCCUPANCY TYPE: AREA OF EXISTING SUITE: AREA OF EXPANSION: TOTAL (AREA OF NEW SUITE): AREA OF WORK: AREA OF FLOOR: APPLICABLE CODES: ASSESSOR'S PARCEL NUMBER: LEGAL DESCRIPTION: BUILDING REPRESENTATIVE: DESIGNER: CONTRACTOR: TENANT IMPROVEMENT TO AN EXISTING SUITE ON THE 5TH FLOOR FOR OFFICE USE TO INCLUDE: • EXPANSION OF EXISTING SUITE (#501) INTO ADJACENT SUITE (#508) • DEMOLITION OF PARTITIONS, DOORS AND RELITES • CONSTRUCTION OF PARTITIONS, DOORS AND RELITES • RELOCATIONS OF LIGHT FIXTURES AND CEILING FIXTURES II -A, FULLY SPRINKLERED B, OFFICE ± 8,985 SQ.FT. ± 665 SQ.FT. ± 9,650 SQ.FT. ± 3,900 SQ. FT. ±13,444 SQ. FT. 2015 INTERNATIONAL BUILDING CODE (IBC) 2015 INTERNATIONAL FIRE CODE (IFC) 2015 INTERNATIONAL MECHANICAL CODE (IMC) ICC/ANSI 117.1- ACCESSIBLE AND USABLE BUILDINGS AND FACILITIES 2015 WASHINGTON STATE ENERGY CODE (WSEC) 2015 INTERNATIONAL FUEL AND GAS CODE (IFGC) 2015 UNIFORM PLUMBING CODE (UPC) 2014 NATIONAL ELECTRICAL CODE (NEC) WASHINGTON INDOOR AIR QUALITY CODE 262304-9021 PARCEL 1 OF CITY OF TUKWILA REVISED SHORT PLAT #77-51-55 AKA BLA #3-79 REC #7904180861 SD PLAT DAF - POR SE 1/4 OF NW 1/4 BEG AT MONUMENTAL INTSN OF C/L'S OF SOUTHCENTER PARKWAY 57TH AVE S & STRANDER BLVD S 164TH ST TH S 8-45-5 E 325.05 FT TH S 0-25-58 E 30 FT TO AN INTSN WITH S MGN SD STRANDER BLVD & TPOB TH CONTG S 0-25-58 E 200 FT TH S 89-45-58 E 350 FT TH S 0-25-58 E 1093.20 FT TH N 89-43-19 W 626.31 FT TO E ALG ARC OF CURVE TO RGT RAD 50 FT THRU C/A 91-11-50 79.53 FT TO S MGN STRANDER BKVD TH S 89-45-58 E 237.72 FT TO TPOB LESS POR OF SD PAR 1 FOR ST UNDER REC NO 8310250922 LESS RD PER SUP COURT #09-2-19459-9 KNT JOHN C. RADOVICH DEVELOPMENT COMPANY 2385 82ND AVENUE SE, SUITE 300, MERCER ISLAND, WA 98040 CONTACT - REBECCA DAVIDSON PHONE - 206.267.6060 EMAIL - rebeccadavidson@jcrdevco.com MARVIN STEIN ASSOCIATES, A NELSON COMPANY 1500 WESTLAKE AVENUE N, SUITE ONE, SEATTLE, WA 98109 CONTACT - LINDA DUCEY PHONE - 206.441.1449 EMAIL - Lducey@marvinstein.com TBD GENERAL NOTES 1. COMPLY WITH ALL APPLICABLE CODES. 2. GENERAL CONTRACTOR SHALL VISIT JOB SITE AND VERIFY FIELD CONDITIONS PRIOR TO PURCHASING MATERIALS OR COMMENCING THE WORK. 3. REPORT ANY DISCREPANCIES BETWEEN ACTUAL FIELD CONDITIONS AND DRAWINGS TO MSA BEFORE PROCEEDING WITH THE WORK. 4. VERIFY THE BUILDING STANDARDS (B/S) BEFORE PROCEEDING WITH THE WORK. 5. OBTAIN ALL REQUIRED PERMITS AND APPROVALS BEFORE PROCEEDING WITH THE WORK. 6. WALLS, PARTITIONS AND CEILINGS SHALL BE INDEPENDENTLY BRACED TO RESIST SEISMIC FORCES. 7. PROVIDE BLOCKING AT ALL WALL MOUNTED ITEMS. 8. ALIGN AND SHIM TRANSITIONS BETWEEN OLD AND NEW CONDITIONS. 9. LEVEL THE FLOOR. DEVIATIONS OF ± 1/2" WITHIN 10'-0" IS THE ACCEPTABLE LIMIT. 10. GENERAL CONTRACTOR SHALL REVIEW AND STAMP OR MARK REQUIRED SUBMITTALS AND SHOP DRAWINGS PRIOR TO SENDING COPIES TO MSA FOR REVIEW AND COMMENT. 11. THE BUILDING OWNER OR THE OWNER'S AUTHORIZED REPRESENTATIVE SHALL ESTABLISH WORKING TIME AND STANDARDS OF CONDUCT. 12. DO NOT SCALE DRAWINGS. 13. GENERAL CONTRACTOR SHALL COORDINATE ACTIVITIES OF ALL SUBCONTRACTORS, DELIVERY, AND STAGING OF MATERIALS. MECHANICAL, PLUMBING, FIRE PROTECTION AND LIFE SAFETY NOTES 1. MECHANICAL, FIRE PROTECTION AND LIFE SAFETY ALTERATIONS AND CONSTRUCTION ARE BY OTHERS, UNDER SEPARATE PERMITS BY DESIGN / BUILD CONTRACTORS - DEFERRED SUBMITTALS. 2. REBALANCE THE HVAC SYSTEM AND PROVIDE WRITTEN REPORT TO OWNER AND/OR MSA. 3. CLEAN ALL DIFFUSERS & GRILLS. 4. VERIFY LOCATION OF THERMOSTATS WITH OWNER OR ARCHITECT PRIOR TO FINAL INSTALLATION. 5. ALL CONSTRUCTION WORK IS CONFINED TO THE BUILDING INTERIOR. CONTRACTOR SHALL PROVIDE BARRIERS OR SYSTEMS TO CONTAIN DUST, DIRT OR DEBRIS TO MINIMIZE INCONVENIENCE DURING CONSTRUCTION TO OTHER TENANTS WITHIN THE BUILDING. 6. CONSTRUCTION OPERATIONS SHALL NOT OBSTRUCT HALLWAYS, CORRIDORS, STAIRWAYS OR MEANS OF EGRESS FOR THE TENANTS OF THE BUILDING. 7. DO NOT DISRUPT HVAC, PLUMBING, ELECTRICAL OR FIRE PROTECTION SYSTEMS WITHOUT PRIOR AUTHORIZATION FROM THE BUILDING REPRESENTATIVE. 8. THE CONSTRUCTION SITE SHALL BE LEFT CLEAN & ORDERLY AT THE END OF EACH WORK DAY. 9. NO ONE WILL OCCUPY THE AREA OF WORK OTHER THAN AUTHORIZED CONSTRUCTION PERSONNEL. 10. THE GENERAL CONTRACTOR SHALL PROVIDE TEMPORARY CONSTRUCTION BARRIERS TO INHIBIT ACCESS BY NON -AUTHORIZED PERSONNEL AND AS REQUIRED BY 0.S.H.A. STANDARDS TO PREVENT INJURIES OR ACCIDE 11. N.F.P.A. / I.F.C. APPROVED FIRE EXTINGUISHERS SHALL BE LOCATED WITHIN 75 FEET FROM ANY POINT ALONG T PATH OF TENANT EGRESS OR AS REQUIRED BY THE LOCAL FIRE MARSHAL. SOUTHCENTER PLACE 16400 SOUTHCENTER PARKWAY TUKWILA, WASHINGTON 98188 ®Y rmit 3 Plan review approval is subject to errors and omissions. Approval of construction documents does not authorize the violation of any adopted code or ordinance. Rr col t of approved Field Copy and conditions is acknowledged: c9,* Date: 3 71 e, / City of Tukwila BUILDING DIVISION REGIS ktit.] DOUGLAS EVAN STATE OF WAsmN(,I(N CO DRAWN BY: TA CHECKED BY: LD JOB NO.: 78011.152 NO. REVISIONS INDICATED THUS n DATE BY ISSUED FOR REVIEW ISSUED REVISION # 1 10/18/16 TA 10/21/16 ME ISSUED FOR PERMIT 11/16/16 TA APPROVAL STAMPS: TENANT: 12. THE SPACE AROUND PIPES DUCTS ETC. PENETRATING FIRE RESISTANT CONSTRUCTION SHALL NOT EXCEED %" AND SHALL BE PACKED SOLID WITH APPROVED FIRE SAFING MATERIAL AND SEALED WITH METAL ESCUTCHEONS EACH SIDE AS REQUIRED BY CODE. 13. MAINTAIN INTEGRITY OF FIRE -RATED ASSEMBLIES AND REPAIR ANY DAMAGE TO SPRAY -APPLIED FIREPROOFING. SHEET INDEX 1032 TI -1 COVER SHEET AND DETAILS TI -2 DEMOLITION PLAN AND CONSTRUCTION PLAN TI -3 REFLECTED CEILING PLAN 8 1 PROJECT INFORMATION, NOTES & SHEET INDEX REVIEWED FOR CODE COMPLIANCE APPROVED DEC 0 6 2016 �L w� r^.ity of Tukwila BUILDING DIVISION E WALSH GROUP EXPANSION (SUITE5OI) SHEET TITLE: COVER SHEET RECEIVED AND DETAILS CITY OF T IUKWIL NOV 212016 PERMIT CENTER REPRODUCTION, ALTERATION OR PUBLICATION OF THIS DRAWING, WITHOUT EXPRESSED PERMISSION BY MSA, IS A VIOLATION OF FEDERAL COPYRIGHT LAW. COPYRIGHT BY MSA 2016. TI -1 OF 3 w U J w v 0 TI -2) WGE—DE&PL-05.dwg DEMOLITION PLAN 0 1/8" =1'-0" DEMOLITION LEGEND EXISTING BUILDING CORE EXISTING CORRIDOR PARTITION EXISTING DEMISING PARTITION TO REMAIN EXISTING CONSTRUCTION TO REMAIN EXISTING CONSTRUCTION TO BE DEMOLISHED, UNO 11 -♦ n s EXISTING DOOR AND RELITE TO BE 6—" REMOVED, UNO (S = SALVAGED ) DEMOLITION KEYNOTES 0 REMOVE EXISTING CLERESTORY RELITE, SALVAGE FOR REUSE IN ENLARGED CONFERENCE ROOM, SEE CONSTRUCTION PLAN 2/TI-2. 02 REMOVE EXISTING FLOORING AND PREP FLOOR TO ACCEPT NEW FLOOR COVERING. DEMOLITION NOTES 1. A CLEAR PATH OF EGRESS TRAVEL SHALL REMAIN OPEN AT ALL TIMES DURING DEMOLITION. 2. DISRUPTION OF THE BUILDING FIRE ALARM, ELECTRICAL POWER, WATER, OR LIFE SAFETY SYSTEMS MUST BE COORDINATED WITH ALL GOVERNING AGENCIES AND THE BUILDING REPRESENTATIVE. 3. ALL DEBRIS SHALL BE REMOVED FROM THE DEMOLITION SITE DAILY. 4. ALL DEMOLITION SHALL BE PERFORMED IN ACCORDANCE WITH THE BUILDING REPRESENTATIVE'S RULES AND REGULATIONS WITH MINIMAL DISTURBANCE TO OTHER TENANTS. 5. CONTRACTOR SHALL PROVIDE DUST BARRIERS FOR PROTECTION OF EXISTING ADJACENT AREAS. ALL HVAC SYSTEMS ARE TO BE PROTECTED DURING DEMOLITION. 6. CONTRACTOR SHALL NOTIFY BUILDING REPRESENTATIVE AND MSA OF ANY DEMOLITION WORK THAT IMPACTS THE STRUCTURAL INTEGRITY OF THE BUILDING. 7. GENERAL CONTRACTOR SHALL IMMEDIATELY REPORT ALL ACCIDENTS, ERRORS OR DEFECTS TO THE BUILDING REPRESENTATIVE. 5' 10' 20' 30' NORTH EXISTING OFFICE EXISTING OFFICE OPEN WORK AREA NEW SHARED OFFICE EXISTING WORK ROOM NEW SHARED OFFICE NEW CONFERENCE CONSTRUCTION PLAN c_ COLUMN 1/8" =1'-0" CONSTRUCTION LEGEND EXISTING EUILDING CORE EXISTING CORRIDOR PARTITION EXISTING DEMISING PARTITION EXISTING PARTITION, UNO NEW B/S CORRIDOR PARTITION PER DETAIL 7/TI-1 NEW B/S TENANT INTERIOR PARTITION PER DETAIL 6/TF1 a I c RELOCATED OR NEW BIS 2'-0" WIDE X BIS HEIGHT R / N TEMPERED SAFETY GLASS RELITE. MATCH TENANTS EXISTING CONDITIONS. R RELOCATE EXISTING CLERESTORY RELITE TO BIS DOOR HEIGHT. MATCH TENANT'S EXISTING CONDITIONS. SEE DEMOLITION KEYNOTE 1. FEC EXISTING FIRE EXTINGUISHER CABINET FE -c - EXISTING FIRE EXTINGUISHER IALIGN CONSTRUCTION KEYNOTES 1O UPGRADE EXISTING PARTITION TO MATCH B/S DEMISING PARTITION. 0 VERIFY EXISTING DOOR AND RELITE WOOD FINISH IN EXPANSION AREA. MATCH TENANT'S DOOR AND RELITE EXISTING WOOD FINISH IF NECESSARY. O VERIFY WITH TENANT WHETHER TO PROVIDE SOUND INSULATION IN NALL PARTITION AND ABOVE CEILING GRID, PER DETAIL 71T-1. PROVIDE NEW FLOOR COVERING AND NEW PAINT IN EXPANSION AREA. VERIFY SPECIFIC AREA'S WITH TENANT. CONSTRUCTION NOTES 0 10' 20' 1. MAINTAIN A CLEAR PATH OF TRAVEL AT ALL TIMES DURING CONSTRUCTION. 2. DISRUPTION OF THE BUILDING FIRE ALARM, ELECTRICAL POWER, WATER, OR LIFE SAFETY SYSTEMS MUST BE COORDINATED WITH ALL GOVERNING AGENCIES & THE BUILDING OWNER / MANAGEMENT AND TENANT. 3. INSTALL DOUBLE STUDS AT DOOR JAMBS AND HEADERS. 4. DIMENSIONS ARE FINISH SURFACE TO FINISH SURFACE, U.N.O. 5. REPORT ANY DISCREPANCIES BETWEEN THE DRAWINGS AND ACTUAL FIELD CONDITIONS TO MSA. 6. ALL EXISTING WINDOW COVERINGS TO BE CLEANED AND IN GOOD WORKING ORDER. DOOR SCHEDULE 30' NORTH DOOR NUMBER 4 TYPE OF DOOR A. RELOCATED OR NEW B/S 3'-0" WIDE SC WOOD DOOR IN BIS WOOD FRAME HARDWARE a. B/S LATCHSET b. B/S LOCK SET AND CLOSER 6", UNLESS OTHERWISE NOTED EXISTING DOOR TO REMAIN NOTES: 1. PROVIDE CODE COMPLIANT HARDWARE. ALL HARDWARE TO BE LEVER -TYPE. HANDLES, PULLS, LATCHES, LOCKS, AND OTHER OPERABLE PARTS ON ACCESSIBLE DOORS SHALL HAVE A SHAPE THAT IS EASY TO GRASP WITH ONE HAND AND DOES NOT REQUIRE TIGHT GRASPING, PINCHING, OR TWISTING OF THE WRIST TO OPERATE. OPERABLE PARTS OF SUCH HARDWARE SHALL BE 34" MIN. AND 48" MAX. ABOVE THE FLOOR. 2. THE MAXIMUM FORCE FOR PUSHING OR PULLING OPEN DOORS OTHER THAN FIRE DOORS SHALL BE AS FOLLOWS: INTERIOR HINGED DOOR = 5.0 POUNDS (22.2 N), SLIDING OR FOLDING DOOR = 15.0 POUNDS (67 N). THESE FORCES DO NOT APPLY TO THE FORCE REQUIRED TO RETRACT LATCH BOLTS OR DISENGAGE OTHER DEVICES THAT HOLD THE DOOR IN A CLOSED POSITION. FIRE DOORS SHALL HAVE A MINIMUM OPENING FORCE ALLOWABLE BY THE APPROPRIATE ADMINISTRATIVE AUTHORITY. 3. THRESHOLDS AT DOORWAYS SHALL NOT EXCEED 0.5 INCH (12.7 MM) IN HEIGHT. RAISED THRESHOLDS AND FLOOR LEVEL CHANGES GREATER THAN 0.25 INCH (6.4 MM) AT DOORWAYS SHALL BE BEVELED WITH A SLOPE NOT GREATER THAN ONE UNIT VERTICAL IN TWO UNITS HORIZONTAL (50 -PERCENT SLOPE). 4. EXIT DOORS MUST REMAIN UNLOCKED AT ALL TIMES IN THE DIRECTION OF EGRESS. PASSAGE EXIT HARDWARE SHALL REQUIRE NO SPECIAL KNOWLEDGE OR ASSISTANCE TO OPEN OR TO ACCESS. REVIEWED FOR CODE COMPLIANCE APPROVED DEC 0 € 2016 City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA NOV 21 2016 PERMIT CENTER SOUTHCENTER PLACE 16400 SOUTHCENTER PARKWAY TUKWILA, WASHINGTON 98188 KI:tilSujoii 'I'1117iu'i AN KD�� STM I.OF W.ASIIIN<iTON DRAWN BY: TA CHECKED BY: LD JOB NO.: 78011.152 NO. REVISIONS INDICATED THUS n DATE BY ISSUED FOR REVIEW 10/18/16 TA ISSUED REVISION # 1 10/21/16 ME ISSUED FOR PERMIT 11/16/16 TA APPROVAL STAMPS: TENANT: THE WALSH GROUP EXPANSION (SUITE5OI ) SHEET TITLE: L CONSTRUCTION PLANS REPRODUCTION, ALTERATION OR PUBLICATION OF THIS DRAWING, WITHOUT EXPRESSED PERMISSION BY MSA, IS A VIOLATION OF FEDERAL COPYRIGHT LAW. COPYRIGHT 8Y MSA 2016. TI -2 OF 3 SOUTHCENTER PLACE 01 0 • 0 01 0 0 in 0 REFLECTED CEILING PLAN 0 1/8" = 1'-0" CEILING LEGEND EXISTING CEILING GRID AND TILES TO REMAIN. EXISTING 2'X4' RECESSED FLUORESCENT LIGHT FXTURE TO REMAIN. ---- EXISTING 2'X4' RECESSED FLUORESCENT LIGHT FXTURE TO BE REMOVED / RELOCATED. EXISTING 2'X2' RECESSED FLUORESCENT LIGHT FXTURE TO BE REMOVED. RELOCATED 2'X4' RECESSED FLUORESCENT LIGHT FIXTURE. EXISTING / RELOCATED 2'X4' RECESSED FLUORESCENT LIGHT FIXTURES TO BE UPGRADED FOR EMERGENCY LIGHTING. LNYOUT SHOWN IS CONCEPTUAL ONLY. O EXISTING RECESSED FLUORESCENT DDWNLIGHT TO REMAIN. Ys NEW BIS ILLUMINATED EXIT SIGN (DIRECTIONAL VfHERE SHOWN). (E = EXISTING) EXISTING ILLUMINATED EXIT SIGN TO BE RELOCATED. (E) (3) NEW BIS LIGHT SWITCH. (M) (E = EXISTING, 3 = THREE WAY, M = SUITE MASTER) CEILING KEYNOTES O O O VERIFY LOCATION WITH TENANT AND RELOCATE EXISTING PROJECTOR. PROVIDE BRACING, ELECTRICAL AND DATA AS REQUIRED. EXPANSION OPEN AREA LIGHTING TO BE SWITCHED WITH EXISTING OPEN AREA. ASSUMED LIGHTING LIGHTING LAYOUT IN THIS SPACE TO BE VERIFIED. CEILING NOTES 5' 10' 20' 1. CHECK FOR CONFLICTS BEFORE INSTALLING OR RELOCATING LIGHT FIXTURES. NOTIFY MSA OF ANY CONFLICT(S). 2. REPLACE DAMAGED CEILING TILES AND GRID AS NECESSARY TO BRING CEILING TO "LIKE NEW" CONDITION. 3. MAINTAIN EXISTING ONE FOOTCANDLE PER SQUARE FOOT AT EGRESS PATHWAY LIGHTING. 4. MAINTAIN 42" CLEAR SPACE IN FRONT OF THE PANEL SIDE OF ANY V.A.V. BOXES. 5. DAYLIGHT ZONE CONTROL: DAY LIGHTING AS DEFINED BY CODE SHALL BE PROVIDED WITH INDIVIDUAL CONTROLS, OR DAYLIGHT OR OCCUPANT SENSING AUTOMATIC CONTROLS PER SECTION C405.2.2.2 OF THE WASHINGTON STATE ENERGY CODE. 6. FIRE SPRINKLER INSTALLATION TO BE DESIGN -BUILD WITH DEFERRED PERMIT SUBMITTALS. 7. COMMISSIONING REQUIREMENTS: TEST LIGHTING CONTROLS TO ENSURE THAT THE SYSTEMS COMPLY WITH CODES. PROVIDE A WRITTEN REPORT OF TEST PROCEDURES AND RESULTS TO THE OWNER. USE OCCUPANCY SENSORS AS REQUIRED. 8. EXIT SIGNS ARE INDICATED ON THE REFLECTED CEILING PLAN. THEIR FINAL PLACEMENT IS TO BE COORDINATED IN THE FIELD WITH THE INSPECTOR. LIGHTING CALCULATION EXISTING CEILING GRID, TILE AND FIXTURES TO REMAIN. EXISTING LIGHTING LAYOUT USES 57 FIXTURES. THE NEW LAYOUT RELOCATES 18 OF THE EXISTING FIXTURES. 18/57 x 100 = 32% WHICH IS LESS THAN THE 60% ALLOWABLE CHANGE PER 2015 WSEC LIGHTING ALTERATION EXCEPTION C101.4.3.1. PROJECT COMPLIES. 30' NORTH REVIEWED FOR CODE COMPLIANCE APPROVED •r ' DEC 0 C 2016 City of Tukwila BUILDING DIVISION SOUTHCENTER PLACE 16400 SOUTHCENTER PARKWAY TUKWILA, WASHINGTON 98188 M K DOUGLAS EVA S1.1 ATE or N ASI IIN(I R)N DRAWN BY: TA CHECKED BY: LD JOB NO.: 78011.152 NO. REVISIONS INDICATED THUS A DATE BY ISSUED FOR REVIEW 10/18/16 TA ISSUED REVISION # 1 10/21/16 ME ISSUED FOR PERMIT 11/16/16 TA APPROVAL STAMPS: TENANT: THE WALSH GROUP EXPANSION rt( SUITE 501 ) • RECEIVED CITY OF TUKWILA NOV 21 2016 PERMIT CENTER REFLECTED CEILING PLAN REPRODUCTION, ALTERATION OR PUBLICATION OF THIS DRAWING, WITHOUT EXPRESSED PERMISSION BY MSA, IS A VIOLATION OF FEDERAL COPYRIGHT LAW. COPYRIGHT BY MSA 2016. TI -3 OF 3 SOUTHCENTER PLACE r { gZT y $.!{ f ss.? l .a' y 'i L .� � JI O���� � � ,� �� �� � ,,� , £ �> 507 £ � 47-•\...ct � P' f F zy7 ..... 5��' Z A� ) =9- B,V� k i ice'' Q. o 1 512 I f Ew IQs Y� a iq ',' / F x j 1.-. I ===m9 506 REFLECTED CEILING PLAN 0 1/8" = 1'-0" CEILING LEGEND EXISTING CEILING GRID AND TILES TO REMAIN. EXISTING 2'X4' RECESSED FLUORESCENT LIGHT FXTURE TO REMAIN. ---- EXISTING 2'X4' RECESSED FLUORESCENT LIGHT FXTURE TO BE REMOVED / RELOCATED. EXISTING 2'X2' RECESSED FLUORESCENT LIGHT FXTURE TO BE REMOVED. RELOCATED 2'X4' RECESSED FLUORESCENT LIGHT FIXTURE. EXISTING / RELOCATED 2'X4' RECESSED FLUORESCENT LIGHT FIXTURES TO BE UPGRADED FOR EMERGENCY LIGHTING. LNYOUT SHOWN IS CONCEPTUAL ONLY. O EXISTING RECESSED FLUORESCENT DDWNLIGHT TO REMAIN. Ys NEW BIS ILLUMINATED EXIT SIGN (DIRECTIONAL VfHERE SHOWN). (E = EXISTING) EXISTING ILLUMINATED EXIT SIGN TO BE RELOCATED. (E) (3) NEW BIS LIGHT SWITCH. (M) (E = EXISTING, 3 = THREE WAY, M = SUITE MASTER) CEILING KEYNOTES O O O VERIFY LOCATION WITH TENANT AND RELOCATE EXISTING PROJECTOR. PROVIDE BRACING, ELECTRICAL AND DATA AS REQUIRED. EXPANSION OPEN AREA LIGHTING TO BE SWITCHED WITH EXISTING OPEN AREA. ASSUMED LIGHTING LIGHTING LAYOUT IN THIS SPACE TO BE VERIFIED. CEILING NOTES 5' 10' 20' 1. CHECK FOR CONFLICTS BEFORE INSTALLING OR RELOCATING LIGHT FIXTURES. NOTIFY MSA OF ANY CONFLICT(S). 2. REPLACE DAMAGED CEILING TILES AND GRID AS NECESSARY TO BRING CEILING TO "LIKE NEW" CONDITION. 3. MAINTAIN EXISTING ONE FOOTCANDLE PER SQUARE FOOT AT EGRESS PATHWAY LIGHTING. 4. MAINTAIN 42" CLEAR SPACE IN FRONT OF THE PANEL SIDE OF ANY V.A.V. BOXES. 5. DAYLIGHT ZONE CONTROL: DAY LIGHTING AS DEFINED BY CODE SHALL BE PROVIDED WITH INDIVIDUAL CONTROLS, OR DAYLIGHT OR OCCUPANT SENSING AUTOMATIC CONTROLS PER SECTION C405.2.2.2 OF THE WASHINGTON STATE ENERGY CODE. 6. FIRE SPRINKLER INSTALLATION TO BE DESIGN -BUILD WITH DEFERRED PERMIT SUBMITTALS. 7. COMMISSIONING REQUIREMENTS: TEST LIGHTING CONTROLS TO ENSURE THAT THE SYSTEMS COMPLY WITH CODES. PROVIDE A WRITTEN REPORT OF TEST PROCEDURES AND RESULTS TO THE OWNER. USE OCCUPANCY SENSORS AS REQUIRED. 8. EXIT SIGNS ARE INDICATED ON THE REFLECTED CEILING PLAN. THEIR FINAL PLACEMENT IS TO BE COORDINATED IN THE FIELD WITH THE INSPECTOR. LIGHTING CALCULATION EXISTING CEILING GRID, TILE AND FIXTURES TO REMAIN. EXISTING LIGHTING LAYOUT USES 57 FIXTURES. THE NEW LAYOUT RELOCATES 18 OF THE EXISTING FIXTURES. 18/57 x 100 = 32% WHICH IS LESS THAN THE 60% ALLOWABLE CHANGE PER 2015 WSEC LIGHTING ALTERATION EXCEPTION C101.4.3.1. PROJECT COMPLIES. 30' NORTH REVIEWED FOR CODE COMPLIANCE APPROVED •r ' DEC 0 C 2016 City of Tukwila BUILDING DIVISION SOUTHCENTER PLACE 16400 SOUTHCENTER PARKWAY TUKWILA, WASHINGTON 98188 M K DOUGLAS EVA S1.1 ATE or N ASI IIN(I R)N DRAWN BY: TA CHECKED BY: LD JOB NO.: 78011.152 NO. REVISIONS INDICATED THUS A DATE BY ISSUED FOR REVIEW 10/18/16 TA ISSUED REVISION # 1 10/21/16 ME ISSUED FOR PERMIT 11/16/16 TA APPROVAL STAMPS: TENANT: THE WALSH GROUP EXPANSION rt( SUITE 501 ) • RECEIVED CITY OF TUKWILA NOV 21 2016 PERMIT CENTER REFLECTED CEILING PLAN REPRODUCTION, ALTERATION OR PUBLICATION OF THIS DRAWING, WITHOUT EXPRESSED PERMISSION BY MSA, IS A VIOLATION OF FEDERAL COPYRIGHT LAW. COPYRIGHT BY MSA 2016. TI -3 OF 3 SOUTHCENTER PLACE