HomeMy WebLinkAboutPermit D16-0325 - AVURE TECHNOLOGIES - NEW FACTORYAVURE TECHNOLOGIES 4475 S 134T" PL BLDG B D16-0325 Parcel No: Address: City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-438-9350 Web site: htto://www.TukwilaWA.gov DEVELOPMENT PERMIT 2613200084 Permit Number: 4475 S 134TH PL BLDG B Issue Date: Permit Expires On: Project Name: AVURE TECHNOLOGIES D16-0325 12/30/2016 6/28/2017 Owner: Name: Address: REALTY ASSOCIATES FUND X LP 1301 DOVE ST #860 , NEWPORT BEACH, WA, 92660 Contact Person: Name: DAVID KEHLE Address: Contractor: Name: Address: License No: Lender: Name: 1913 BONAIR DR SW , SEATTLE, WA, 98116 PRECISION BUILDERS INC PO BOX 98609 , DES MOINES, WA, 98198-0609 PRECIBI151C2 KIDDER MATHEWS Address: 631 STRANDER BLVD SUITE G , TUKWILA, WA, 98188 Phone: (206) 433-8997 Phone: (206) 878-2948 Expiration Date: 1/19/2018 DESCRIPTION OF WORK: CONSTRUCT NEW NON-BEARING WALLS FOR NEW FACTORY SPACE WITH NEW SUSPENDED CEILING AND OVER SUSPENDED CEILING FOR INSULATION Project Valuation: $43,560.00 Type of Fire Protection: Sprinklers: YES Fire Alarm: Type of Construction: VB Electrical Service Provided by: TUKWILA Fees Collected: $1,519.38 Occupancy per IBC: B Water District: 125 Sewer District: VALLEY VIEW,TUKWILA Current Codes adopted by the City of Tukwila: International Building Code Edition: International Residential Code Edition: International Mechanical Code Edition: Uniform Plumbing Code Edition: International Fuel Gas Code: 2015 2015 2015 2015 2015 National Electrical Code: WA Cities Electrical Code: WAC 296-46B: WA State Energy Code: 2014 2014 2014 2015 Public Works Activities: Channelization/Striping: Curb Cut/Access/Sidewalk: Fire Loop Hydrant: Flood Control Zone: Hauling/Oversize Load: Land Altering: Landscape Irrigation: Sanitary Side Sewer: Sewer Main Extension: Storm Drainage: Street Use: Water Main Extension: Water Meter: Volumes: Cut: 0 Fill: 0 Number: 0 No relPermit Center Authorized Signature:0k/ / Date: I hearby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this development permit and agree to the conditions attached to this permit. Signature: Print Name: Date: /2.-.30 ,-7,.6 This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: ***BUILDING PERMIT CONDITIONS*** 2: Work shall be installed in accordance with the approved construction documents, and any changes made during construction that are not in accordance with the approved construction documents shall be resubmitted for approval. 3: All permits, inspection record card and approved construction documents shall be kept at the site of work and shall be open to inspection by the Building Inspector until final inspection approval is granted. 4: New suspended ceiling grid and light fixture installations shall meet the seismic design requirements for nonstructural components. ASCE 7, Chapter 13. 5: All construction shall be done in conformance with the Washington State Building Code and the Washington State Energy Code. 6: There shall be no occupancy of a building until final inspection has been completed and approved by Tukwila building inspector. No exception. 7: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 11: The total number of fire extinguishers required for a light hazard occupancy with Class A fire hazards is calculated at one extinguisher for each 3,000 sq. ft. of area. The extinguisher(s) should be of the "all purpose" (2A, 10 B:C) dry chemical type. The travel distance to any extinguisher must be 75' or less. (IFC 906.3) (NFPA 10, 5.4) 12: The total number of fire extinguishers required for an ordinary hazard occupancy with Class A fire hazards is calculated at one extinguisher for each 1,500 sq. ft. of area. The extinguisher(s) should be of the "All Purpose" (3A, 40B:C) dry chemical type. Travel distance to any fire extinguisher must be 75' or less. (IFC 906.3) (NFPA 10, 5.4) 8: Portable fire extinguishers, not housed in cabinets, shall be installed on the hangers or brackets supplied. Hangers or brackets shall be securely anchored to the mounting surface in accordance with the manufacturer's installation instructions. Portable fire extinguishers having a gross weight not exceeding 40 pounds (18 kg) shall be installed so that its top is not more than 5 feet (1524 mm) above the floor. Hand- held portable fire extinguishers having a gross weight exceeding 40 pounds (18 kg) shall be installed so that its top is not more than 3.5 feet (1067 mm) above the floor. The clearance between the floor and the bottom of the installed hand-held extinguishers shall not be less than 4 inches (102 mm). (IFC 906.7 and. IFC 906.9) 9: Extinguishers shall be located in conspicuous locations where they will be readily accessible and immediately available for use. These locations shall be along normal paths of travel, unless the fire code official determines that the hazard posed indicates the need for placement away from normal paths of travel. (IFC 906.5) 10: Fire extinguishers require monthly and yearly inspections. They must have a tag or label securely attached that indicates the month and year that the inspection was performed and shall identify the company or person performing the service. Every six years stored pressure extinguishers shall be emptied and subjected to the applicable recharge procedures. If the required monthly and yearly inspections of the fire extinguisher(s) are not accomplished or the inspection tag is not completed, a reputable fire extinguisher service company will be required to conduct these required surveys. (NFPA 10, 7.2, 7.3) 13: Maintain fire extinguisher coverage throughout. 14: Egress doors shall be readily openable from the egress side without the use of a key or special knowledge or effort. (IFC 1008.1.8.3 subsection 2.2) 15: Dead bolts are not allowed on auxiliary exit doors unless the dead bolt is automatically retracted when the door handle is engaged from inside the tenant space. (IFC Chapter 10) 16: Exit hardware and marking shall meet the requirements of the International Fire Code. (IFC Chapter 10) 17: Door handles, pulls, latches, locks and other operating devices on doors required to be accessible by Chapter 11 of the International Building Code shall not require tight grasping, tight pinching or twisting of the wrist to operate. (IFC 1008.1.9.1) 18: Aisles and aisle access ways serving as a portion of the exit access in the means of egress system shall comply with the requirements of this section. Aisles or aisle access ways shall be provided from all occupied portions of the exit access which contain seats, tables, furnishings, displays and similar fixtures or equipment. The required width of aisles shall be unobstructed. (IFC 1017.1) 22: Fire protection systems shall be maintained in accordance with the original installation standards for that system. Required systems shall be extended, altered or augmented as necessary to maintain and continue protection whenever the building is altered, remodeled or added to. Alterations to fire protection systems shall be done in accordance with applicable standards. (IFC 901.4) 20: Sprinklers shall be installed under fixed obstructions over 4 feet (1.2 m) wide. (NFPA 13-8.6.5.3.3) 19: All new sprinkler systems and all modifications to existing sprinkler systems shall have fire department review and approval of drawings prior to installation or modification. New sprinkler systems and all modifications to sprinkler systems involving more than 50 heads shall have the written approval of Factory Mutual or any fire protection engineer licensed by the State of Washington and approved by the Fire Marshal prior to submittal to the Tukwila Fire Prevention Bureau. No sprinkler work shall commence without approved drawings. (City Ordinance No. 2436). 24: Maintain fire alarm system audible/visual notification. Addition/relocation of walls or partitions may require relocation and/or addition of audible/visual notification devices. (City Ordinance #2437) 23: All new fire alarm systems or modifications to existing systems shall have the written approval of The Tukwila Fire Prevention Bureau. No work shall commence until a fire department permit has been obtained. (City Ordinance #2437) (IFC 901.2) 25: An electrical permit from the City of Tukwila Building Department Permit Center (206-431-3670) is required for this project. 26: The maximum flame spread class of finish materials used on interior walls and ceilings shall not exceed that set forth in Table No. 803.9 of the International Building Code. 21: Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (City Ordinances #2436 and #2437) 27: Any overlooked hazardous condition and/or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. 28: These plans were reviewed by Inspector 511. If you have any questions, please call Tukwila Fire Prevention Bureau at (206)575-4407. 29: The property owner shall correct backflow deficiencies (RPPA & DCVA installation) within reasonable time since the water lines are shared by multiple bldgs. with different owners. PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 1700 BUILDING FINAL** 1400 FIRE FINAL 0409 FRAMING 0603 ROOF/CEILING INSUL 0406 SUSPENDED CEILING 0601 WALL INSULATION } CITY OF TUKWILA Community Development Department Public Works Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 \\\t\\.1uk\\il,t\\.\o'. Building Permit No. Project No. Date Application Accepted: Date Application Expires: - —I 7 (For office use only) CONSTRUCTION PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **Please Print** SITE LOCATION Site Address:l .-1 � j 13,4'_y ' Tenant Name: H� U e/t �O t,41ire7 • King Co Assessor's Tax No.: Z(13Z04784- Suite Number: Floor: New Tenant: [i Yes$.No PROPERTY OWNER�,,� alp Name: yiet CI iw/i— r wl Name ktv I- t „ Address:' .112,41,ipaz. t5tX 1%jt/4� e lila) 114 State b. Zipig Ogg CONTACT PERSON — person receiving all project communication alp Name: yiet CI iw/i— r wl Address: 1q Ile tQ Miz '( CityodCPDD�t,H�►16 1 i Stat Zipt(81,14, Phone: ft. 433.Emil Fax 404 . S2,_q %(rl�v j Email: Ve, t'lt�� 'e ali��Q,ll�'"��[[%cort GENERAL CONTRACTOR INFORMATION Company Name: Architect Name:1-44,12 ren 4 Address: vivo 5 12 w City: d%6L.Id�t �. State\ . Zip:a�f ti 1d*5, Address: Email: ►l C' (1LoIleaV'G t.coivt Engineer Name: City: State: Address: Zip: Phone: Fax: City: Contr Reg No.: Zip: Exp Date: Tukwila Business License No.: Email: H:\Applications\Fors-Applications On Line\2011 Applications\Pemut Application Revised - 8-9-11.docc Revised: August 2011 bh ARCHITECT OF RECORD Company Name: am , i 2.GNc ►a- t Architect Name:1-44,12 ren 4 Address: vivo 5 12 w City: d%6L.Id�t �. State\ . Zip:a�f ti 1d*5, Phonei/,►Gv�_ 1 Fax:SAD~!44O_ Email: ►l C' (1LoIleaV'G t.coivt ENGINEER OF RECORD pyo fait 1,32 Name: * 5tiveolit1 �^i�' Address: Company Name: 14/4 Engineer Name: Address: City: State: Zip: Phone: Fax: Email: LENDER/BOND ISSUED (required for projects $5,000 or greater per RCW 19.27.095) pyo fait 1,32 Name: * 5tiveolit1 �^i�' Address: City: State: Zip: Page 1 of 4 BUILDING PERMIT INFORMATION — 206-431-3670 Valuation of Project (contractor's bid price): $ 4'1 r'f %D Existing Building Valuation: $ g Describe the scope of work (please provide detailed information): ALD Odd GtIuotv. deibiLki-. Wilb oil Will there be new rack storage? ❑ Yes „'. No If yes, a separate permit and plan submittal will be required. Provide All Building Areas in Square Footage Below PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide�fthe following: Lot Area (sq ft): .207/2:? Floor area of principal dwelling: 'r* Floor area of accessory dwelling: "----' *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: ' Compact: Handicap: Will there be a change in use? te........ ,Yes 0 No If "yes", explain: M4'7` 11' 't "iD 1 FIRE PROTECTION/HAZARDOUS MATERIALS: Sprinklers 0 Automatic Fire Alarm ❑ None 0 Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? 0 Yes e+. No If `yes', attach list of materials and storage locations on a separate 8-1/2"x 11" paper including quantities and Material Safety Data Sheets. SEPTIC SYSTEM 0 On-site Septic System — For on-site septic system, provide 2 copies of a current septic design approved by King County Health Department. H:\Applications\Forms-Applications On Line\2011 Applications\Pernut Application Revised - 8-9-11.doce Revised: August 2011 bh Page 2 of 4 Existing Interior Remodel Addition to Existing Sttrlu�cttu�re New Type of Construction per IBC Type of Occupancy per IBC 151 Floor �f41`I.Q 1 v �j M2i 1'�'i+'�P 1-15-�f 9/A1 i 2nd Floor 3rd Floor Floors thru Basement Accessory Structure* Attached Garage Detached Garage Attached Carport Detached Carport . Covered Dt;ck • Uncovered Deck PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide�fthe following: Lot Area (sq ft): .207/2:? Floor area of principal dwelling: 'r* Floor area of accessory dwelling: "----' *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: ' Compact: Handicap: Will there be a change in use? te........ ,Yes 0 No If "yes", explain: M4'7` 11' 't "iD 1 FIRE PROTECTION/HAZARDOUS MATERIALS: Sprinklers 0 Automatic Fire Alarm ❑ None 0 Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? 0 Yes e+. No If `yes', attach list of materials and storage locations on a separate 8-1/2"x 11" paper including quantities and Material Safety Data Sheets. SEPTIC SYSTEM 0 On-site Septic System — For on-site septic system, provide 2 copies of a current septic design approved by King County Health Department. H:\Applications\Forms-Applications On Line\2011 Applications\Pernut Application Revised - 8-9-11.doce Revised: August 2011 bh Page 2 of 4 PERMIT APPLICATION NOTES — Value of Construction —In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OW Signature: Print Name: ilty Keit,* ei+ RIZED AGENT: Mailing Address: Mt,&/ tNDt2 EL H:\Applications\Form-Applications On Linel2011 Applications\Permit Application Revised - 8-9-11.docx Revised: August 2011 bh Date: itIM,4Le Day Telephone:1M' 4'33 "b' ' 1I Lp State Zip City Page 4 of 4 Cash Register Receipt City of Tukwila DESCRIPTIONS I ACCOUNT QUANTITY PermitTRAK PAID $940.16 D16-0325 Address: 4475 S 134TH PL BLDG B Apn: 2613200084 $940.16 DEVELOPMENT $895.60 PERMIT FEE R000.322.100.00.00 0.00 $891.10 WASHINGTON STATE SURCHARGE B640.237.114 0.00 $4.50 TECHNOLOGY FEE $44.56 TECHNOLOGY FEE TOTAL FEES PAID BY RECEIPT: R10228 R000.322.900.04.00 0.00 $44.56 $940.16 Date Paid: Friday, December 30, 2016 Paid By: PRECISION BUILDERS INC Pay Method: CHECK 12022 Printed: Friday, December 30, 2016 12:32 PM 1 of 1 RSYSTEMS Cash Register Receipt City of Tukwila DESCRIPTIONS ACCOUNT QUANTITY PAID PermitTRAK $579.22 D16-0325 Address: 4475 S 134TH PL BLDG B Apn: 2613200084 $579.22 DEVELOPMENT $579.22 PLAN CHECK FEE TOTAL FEES PAID BY RECEIPT: R9934 R000.345.830.00.00 0.00 $579.22 $579.22 Date Paid: Tuesday, November 29, 2016 Paid By: DAVID KEHLE Pay Method: CREDIT CARD 05937D Printed: Tuesday, November 29, 2016 11:32 AM 1 of 1 CSYSTEMS WIINSPECTION RECORD Retain a copy with permit INS ION ION NO. ma -03 PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 Permit Inspection Request Line (206) 438-9350 (206) 431-3670 Project: my - .6a-two-/y. Ty.p.a of Insppejctio%n: `,,,,,,j�(/, AL - Address: YY /4/7s` s ;9,103 PL Date Called: Special Instructions: p t Date W d: a.m: Reques ' r: Otey Phone No: 206 Iclo Approved per applicable codes. 4 Corrections required prior to approval. COMMENTS: l Pii.�t/Wl?31 Ar6 1 ffv4.1-, AP P2474 L 06.41aftb )2S A%Z, Air- ix s1/ S �/AvG aL14, 17-77 . /, Wd(17*t esJ 7l P Inspector: REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Prod t: vie .� iwpto ,� Ty a of Inspection: 13:...a r t..N.Q` iL/At Addrress:1 -, 1-1417g- -1 4 /7g- S / q / (] +� Date Called: Special Instructions: ;,.�6. Date Wa e : z s_ 17 p. Request 1 PhoneNo: ?CZ - 346 - 1S-30 KApproved per applicable codes. El Corrections required prior to approval. COMMENTS: Inspector: REINSPECTION FEE REQUIRED. Prior to next inspecfion, fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Projec : AIN sr— i& -JE: Type of Inspection: &; 861�%4v�; f C �' %,���i�i-ir Address: 4/VS S i 34/771 PL. Date Called: 4 Special Instructions:p aieb(,- 8 Date Wan d 7 p.m. Requester Phone No: ElApproved per applicable codes. Corrections required prior to approval. COMMENTS: aft'," 5Art-b_el Peie 671,0A-CrelS 001/1.PL.C--:7 Inspector: Date: a/ ! 7 REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION NO. INSPECTION RECORD Retain a copy with permit 1/6- -03air PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Pro Ur - Ill, /Cs Te of Inspection: oe o 4.b,4 tt(* -- Address: liq 7r- "5 1341 III Date Called: Special Instructions: Date Wan d: a.m. Requeste•I _ JLICC Phone r1a: ZO 396 /530 9 Approved per applicable codes. Corrections required prior to approval. COMMENTS: �/ AJ "LL +` 12-42 ee,AffiVerrVA 12,,,q&ks7— kv7- Aby gz /C4L- 4fird41__ Inspector: Date: REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit INS ION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 .b)61 -d325" Proj ct: Al [t 1 f ve-16S Type of Inspection: Sus ba, Cih J& Pe Address: )47CS /?4 Date Called: Special Instructions: Date Wanted:: Requester: ,2 LL ? Phone No: 346- j .?E) Approved per applicable codes. Corrections required prior to approval. COMMENTS: Inspector: Date 7 REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. F-5,--1 INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Projhe t: /i vy 'rib -Wu -464a Type of Ins ection: etyr eltinfe. J4)SU1- Address: I/47S— s `3 /7 PL - Date Ca ed: Special Instructions: � - Date Wanted: 3 211l 7 cW 1 eitey Phone No: Approved per applicable codes. Corrections required prior to approval. COMMENTS: Inspector: Dater 2, p> REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Nee- olgs— PA 'ct: ,� V' 2E !ECillikL&6-fl 3 Type�pof Inspection: UALL l Ai tit- 4r4'7"7oA Address: gigis 5 is/774 Pi, Date Called: Special Instructions: y 1' Date Wanted: j 27 A 7 p.m. Requester: Phone No: Approved per applicable codes. LJ Corrections required prior to approval. COMMENTS: lnspector:i4 REINSPECTION FEE REQUIRED. Prior to next inspec'Iion. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit INSTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 1))41. - Z S - Pro' ct: AWL/r222 TEC I+NoLc'6 S Type nspection: PAM Address: f%7 7S S )N PC Date Called: Special Instructions: y�c.�lr Q 3 Date Wa/ntted `9 /7 P.m. Request . , uw Phone No: -- 3Q6 - / S-30 'Approved per applicable codes. El Corrections required prior to approval. COMMENTS: Inspector: ^ Dater REINSPECTION FEE REQUIRED. Prior to next inspection. fet? must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. INSPECTION NUMBER INSPECTION RECORD Retain a copy with permit 1.— O 2S PERMIT NUMBERS CITY OF TUKWILA FIRE DEPARTMENT 206-575-4407 Project: k''t/(' (�-Ter t Type of Inspection: �YQ Address:, t, Suite #: W7� .S. / 3'-17'-'�' rL Person: Special Instructions: Phone No.: -Approved per applicable codes. Corrections required prior to approval. COMMENTS: Needs Shift Inspection: Sprinklers: Vel Fire Alarm: Hood & Duct: ' NO Monitor: Pre -Fire: Permits: Occupancy Type: Inspector:. ‹-e__ Date: '//z--/ 7 Hrs.: / 0 $100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. Billing Address Attn: Company Name: Address: City: State: Zip: Word/Inspection Record Form.Doc 3/14/14 T.F.D. Form F.P. 113 Envelope Summary ENV -SUM 2015 WSEC Compliance Forms for Commercial Buildings including R2, R3, & R4 over 3 stories and all R1 Revised Jun 2016 Project Info Compliance forms do not require a password to use. Instructional and calculating cells are write -protected. Project Title: / .;-°11. • ,r_ r Date II „Z8),,..1 (.04. Applicant Information. Provide contact information for individual who can respond to inquiries about compliance form information provided. For Building Department Use Company Name: REVIEVVED FOR CODE COMPLIANCE APPROVED BCC 1 5- 2016 Company Address 4F �G% %y�. Applicant Name: yoftrite, ; rt e' l Applicant Phone: (Q. �+?J3.c1 Applicant Email: de L L�,f 4"14, _ r/�+/F Project Description * Alteration ', • New Building • Addition Occupancy Type Selection required to enable forms. S All Commercial 0 Group R - All R1 and R2, R3, R4 o er 3 stGety Wrukwila _ E311II nikir DIVIvION Envelope Compliance Path Selection required to enable forms. prescriptive 40 Component Performance Component Performance Calculation Type Selection required to enable ENV -UA and ENV- C forms. 0 Standard . Change of Occupancy/Conditioning 0 - C406.8 Enhanced Envelope envelope performance is 15% lower than the Target UA. • Additional Efficiency Package Option To comply, demonstrate building thermal J• Air Barrier Testing Air barrier testing not required - C406.9 Reduced Air Infiltration air leakage of building envelope does not exceed 0.25 pressure of 0.3 inch w. g. Air barrier testingper Section C402.5.1.2 included in project scope ■ Additional Efficiency Package Option To comply, demonstrate that measured cfmfft2 (air barrier surface area) under test Vertical Fenestration and Skylight Area Calculation Prescriptive Path - Enter values for vertical fenestration, skylights, gross walls and roof on this ENV -SUM worksheet. Component Performance- Enter values in ENV -UA and/or ENV -UA -GROUP -R worksheet. These values auto -fill from ENV -UA and are write -protected on ENV-_ Total Vertical Gross Exterior Fenestration Above Grade % Vertical (rough opening) divided by Wall Area times 100 equals Fenestration s t..,.i.� _ X 1 00 = l�[JI� ' Gross Exterior Roof Total Skylight divided by Area times 100 equals % Skylight X 100 = Fenestration Area Compliance Vertical Fenestration 4 CIRECEIVED Area TUKWILA Skylight Area IA. NOV 2 9 2016 Vertical Fenestration Alternates 0 High performance fenestration U -factors and SHGC per C402.? RMIT CENTER 0 Dedicated outdoor air system per C402.4.1.4 and C403.6 Show locations of qualifying daylight zone areas and ft2 on project plans. For Daylight Zone Area Calculations - a) Sidelight areas include primary + secondary daylght zone areas. b) Include overlapping toplight and sidelight daylight zone areas under Toplight c) Refer to Chapter 2 for net floor area 0 In buildings z 3 stories, 25% or more of NET floor area is in daylight zones per C402.4.1.1 0 In buildings < 3 stories, 50% or more of CONDITIONED floor area is within daylight zones per C402.4.1.1 Daylight Zone Calculations Daylight Zone Fenestration Altemate Not Selected. No Calculations Required Sidelight Daylight Zone Area Toplight Daylight Zone Area Percent Daylight Zone Area Spaces in Single Story Building Requiring Skylights Code requires a minimum of 50% of the floor area to be within a skylight daylight zone for snecific space woes. Refer to C402.4.2 for List all enclosed spaces that exceed 2,500 ft2, have ceiling height greater than 15 ft, and are space types required to comply with this provision. Space Area (ft2) DLZ Area (ft2) SRR or Aperature Exception f A°"7 u r_ Envelope Requirements Summary, pg 1 ENV -REQ 2015 WSEC Compliance Forms for. Commercial Buildings including R2, R3, & R4 over 3 stories and all RI Revised Jun 2016 Minimum Requirements This table summarizes prescriptive compliance requirements for opaque elements and fenestration. Refer for Prescriptive Compliance to Tables C402.1.3, C402.1.4 and C402.4 In the 2015 WSEC for important footnotes that apply to these tables. Refer to Section C402 for all applicable requirements that apply for each envebpe element type and applicable exceptions. Refer to Section C410 for all applicable information for refrigerated spaces. Prescriptive Path Table C402.1.3 Notes 1,7 Insulation Minimum R -Value Table C402.1.4 Notes 1,2 Assembly Maximum U -factor Occupancy Group All Other 1 Group R All Other 1 Group R Opaque Elements Roofs Insulation Entirely above Deck R-38 c.i. R-38 c.i. U-0.027 U-0.027 Metal Building (with thermal spacer block) Note 3 R-25 + R-11 Ls R-25 + R-11 Ls U-0.031 U-0.031 Attic and Other R-49 R-49 U-0.021 U-0.021 Joist or single rafter R-49 R-49 U-0.027 U-0.027 Walls, Above -grade Mass Note 6 R-9.5 c.i. R-13.3 c.i. Note 6 U-0.104 U-0.078 Mass transfer deck slab edge No R -Value for prescriptive compliance U-0.200 U-0.200 Metal Building R-19 c.i. R-19 c.i. U-0.052 U-0.052 Steel Framed R-13 + R-10e.i. R-19 + R-8.5 c.i. U-0.055 U-0.055 Wood Framed and Other R-21 wl int. frame R-21 w/ int. frame U-0.054 U-0.054 Below Grade Wall Note 4 Same as above grade Same as above grade Floors Mass R-30 c.i. R-30 c.i. U-0.031 U-0.031 Steel Joist R-38 - R-10 c.i. R-38 = R-10 c.i. U-0.029 U-0.029 Wood Framed and Other R-30 R-30 U-0.029 U-0.029 Slab -On -Grade Floors Unheated R-10 for 24 in. (from top of slab) F-0.54 F-0.54 Heated Note 5 R-10 perimeter & under entire stab F-0.55 F-0.55 Opaque Doors Swinging No R -Value for prescriptive compliance U-0.37 U-0.37 Nonswinging (Roll -up or sliding) R-4.75 1 R-4.75 U-0.34 U-0.34 Table C402.4 - 0-30% of wall area. or 30%-40% per Section C402.3.1.1 DLZ or Section C402.3.1.4 DOAS Section C402.3.1.3 High Performance Fenestration Option - 0-40% of wall area Fenestration Assembly Maximum U -factor Notes 1,2 Vertical Fenestration Nonmetal framing U-0.30 U-0.30 U-0.28 U-0.28 Metal framing (fixed) U-0.38 U-0.38 U-0.34 U-0.34 Metal framing (operable) U-0.40 U-0.40 U-0.36 U-0.36 Entrance doors U-0.60 U-0.60 U-0.60 U-0.60 Skylights Skylights U-0.50 U-0.50 U-0.50 U-0.50 Fenestration Assembly Maximum SHGC Factor Vertical Fenestration PF<0.2: north - SHGC=0.53; all other SHGC=0.4 0.2 <_ PF < 0.5: north - SHGC-0.58; all other - SHGC-0.48 PF ? 0.5: all orientations - SHGC-0.64 PF<0.2: north - SHGC=0.46; all other SHGC=0.35 0.2 <_ PF < 0.5: north - SHGC-0.51; all other - SHGC-0.42 PF >_ 0.5: all orientations - SHGC-0.56 Skylights SHGC-0.35 SHGC-0.35 C410.2 Refrigerated Spaces Insulation Insulation Minimum R -Value Assembly Maximum U -factor Freezers - Walk-in and Warehouse Roof l Ceiling R-32 U-0.030 Wall R-32 U-0.030 Door R-32 U-0.030 Door - transparent reach -in triple -pane, heat -reflective treated or gas Floor R-28 U-0.035 Coolers - Walk-in and Warehouse Roof! Ceiling R-25 U-0.039 Wall R-25 U-0.039 Door R-25 U-0.039 Door - transparent reach -in double -pane, heat -reflective treated & gas fill, or comply with freezer door req. Envelope Requirements Summary, pg 2 ENV -REQ 2015 WSEC Compliance Forms for Commercial Buildings including R2, R3, & R4 over 3 stories and all R1 Revised Jun 2016 Definitions: Ls = Liner system -- A continuous membrane installed below the purlins and uninterrupted by framing members. Uncompressed, unfaced insulation rests on top of the membrane between the purlins. Refer to Section A102.2.5.4. c. i. = Continuous insulation — Insulation that is continuous across all structural members without thermal bridges other than service openings and penetrations by metal fasteners with a x -sectional area of less than 0.04% of the opaque surface area of the assembly. Components with more than 0.04% metal penentrations may be eligible to follow the alternate CI values below. int = Intermediate framing -- Includes insulated headers, corners and interior partition wall to exterior wall intersections. Refer to Section A103.2 for framing definitions. Footnote Summary: Each table in the 2015 WSEC has footnotes applicable to specific information provided in the table. This footnote summary provides only abbreviated details from these footnotes. Refer to 2015 WSEC for completefootnote information. Note 1- Assembly descriptions can be found in Chapter2 and Appendix A. Note 2 - Use of assembly U -factors, C-fanominal ctors and F -factors from Appendix A and Chapter 3 are required unless otherwise allowed by the provisions of this Code. Note 3 - For metal building roofs where using R -value compliance method, a thermal spacer block is required. Otherwise use the U -factor compliance method. Note 4 - Where heated slabs are below -grade, below -grade walls shall comply with the exterior insulation requirements for heated slabs. Note 5 - Heated slab F -factors shall be determined specifically for heated slabs. Unheated slab F -factors shall not be used. Note 6 - CMU walls in all occupancies other than Group R may be eligible for reduced insulation if all provisions stated in applicable footnote are met. Refer to Footnote D in Table C402.1.4 or Footnote C in Table C402.1.3 for eligibility requirements. Note 7 - Components with continuous insulation but with metal penetrations / connections may be eligible for alternate continuous insulation R -values if all provisions in applicable footnote are met. Refer to alternate prescriptive R -values in table below and Footnote F in Table C402.1.3 for eligibility requirements. Alternate continuous insulation nominal R -values This alternate nominal R -value compliance option is allowed for projects complying with all of the following: 1. The ratio of the cross-sectional area, as measured in the plane of the surface, of metal penetrations of otherwise continuous insulation to the opaque surface area of the assembly is greater than 0.0004 (0.04%), but less than 0.0012 (0.12%). 2. The metal penetrations of otherwise continuous insulation are isolated or discontinuous (e. g., brick ties or other discontinuous metal attachments, offset brackets supporting shelf angles that allow insulation to go between the shelf angle and the primary portions of the wall structure). No continuous metal elements (e.g., metal studs, z-girts, z -channels, shelf angles) penetrate the otherwise continuous portion of the insulation. 3. Building permit drawings shall contain details showing the locations and dimensions of all the metal penetrations (e.g., brick ties or other discontinuous metal attachments, offset brackets, etc.) of otherwise continuous insulation. In addition, calculations shall be provided showing the ratio of the cross-sectional area of metal penetrations of otherwise continuous insulation to the overall opaque wall area. Assemblies with continuous insulation (see definition) Alternate optica for assestbties with mega penetrations, greater than 0.04% bat less than 0.084b Alternate option for assemblies with stets! pmrtrations, greater than or equal to O.OSlb but less thea 0-12 lei R-9.5ci R.-11.9ci R -13c1 R I1.4ci R-14.3ci R-15.7ci R-13-3ci R-16.6ci R -18.3c1 R-i5.2d R-19.Oci R.-21ci R -30d R-3Sci R-42ci R-3Sd R48a R -53c1 R-13+R•7.5ci R -13+R -9.4c R-13+R-103ci R-13 - R -loci R-13 + R-12.54 R-13 - R-13.Scs R-13+R-12Sd R-I3+R•15.6d R-13+R-172cr R -13+R-130 R -13 -R -163a R-13+R-179ci R-19-R-8.5ci R -19+R-10.64 R -19+R-11.74 R-19 +R -14d R -19-R-17.54 R-19 +R-1924 R -19+R -16a R-19+R-20ci R -19 -R -22d R-20 - R3.Sci R-21 - R-4.Sci R-20 .+ R-5✓3ci R-21-R-5ci R-21+R-6Jd R:21+R .90 End of Envelope Requirements Summary Component Performance Path, pg. 1 ENV -UA 2015 WSEC Compliance Forms for Commercial Buildings including R2, R3, & R4 over 3 stories and all R1 Revised Jun 2016 Project Title: AyUee 5 4.10 er-7 _. Date 11, f45,1 Li, Calculation Adjustments None Applied For Building Department Use Fenestration Area as % gross above -grade wall area a Max. Target: Skylight Area as % gross roof area i`i+'g, Max. Target: Vertical Fenestration Alternates: None Selected on ENV -SUM Envelope Component Cavity+CI i Plan/Detail #!U -factor Source & Table # 2 Proposed UA , U -factor x Area (A) = UA (U x AN Target UA U -factor x Area (A) = UA (U x A) Roofs ,,, oR= R= I R= I I set occ.i Above Deck Insulation set occ. -a m i R= R= I R= set occ.; Metal Building set occ. ct j °,Joist/single .. R= - (���,,�t1y hV� ��''rr11 `` ) R= � � � ldJ�1 � 1 Nuwv7 �I��VU R= C% .i7� �� ;� �� set occ. r fter set occ. & t' t4' q.3' -0 R= R= R= i set occ.; Single raft, attic, other set occ. Opaque Walls - Above Grade4'6 ru cp R=20ir%D !"/luti R='Z 4b,; glila c'de1': so 14.4q ,c,A.0110 Mi 24•`� set occ. Steel/meyta�l f/name tomset �°cc. a 0° 2 R= R= R= , set occ.: Metal Building set occ. Wood/Oth R= i R='Wood i R= set occ.' Frame, other set occ. ,R= in m R= R= set occ.; Mass Wall set occ. u o R= R= set occ.; Mass Transfer Deck set occ. fr 0. o' 6 ,--R= m - ! R= R= I set occ.' Group R Mass Wall set occ. Below Grade ER= O R= I I R= I set occ. Assumed to be Mass Wall set occ. (Group R4•7 R= I R= i R= I set occ., Assumed to be Mass Wall set occ. o LLy , r, R= R= R= set occ., Mass Floor set occ. u. R= R= R= set occ.i Joist/Framing set occ. Page 1 Subtotal area' UA 314 1.241 (161 Area ` UA 3W O 40.411 Component Performance Compliance (UA) Occupancy Group not selected Component Performance Path, pg. 2 ENV -UA 2015 WSEC Compliance Forms for Commercial Buildings including R2, R3, & R4 over 3 stories and all R1 Revised Jun 2016 Project Title: . yue j;kj(ctite/J __ - - Date to fk::,•'/LP' " Fenestration Area as % gross above -grade wall area Max. Target: For Building Department Use Skylight Area as % gross roof area , Max. Target: Building Component Ins. R Plan/Detail #1F -factor Source & Table # 8 Proposed UA F -factor x Perimeter j= UA(U x NF 1 Target UA -factor x Perimeter = UA (U x A) Slab -on -grade Unheated) R= D I R= 1 R= ei� f' 142. 11415.1‘, set occ. '; Slab -On rade set occ. o r5'i 14z. t a3*8 m d = R= R= R= I j set occ.; Heated Slab -On -Grade set occ. Schedule ID IU -factor Source9.10 U -factor x Area (A) = UA (U x A; U -factor x Area (A) = UA (U x A) m o 0 0 c/76'02/21©. •5 u)D.37 � ' c..•'1 l c !2' 4.*,m � set occ. Opaque Swing Doors set occ. (47 2;41 L_ 0 set occ.. Opaque rollup & sliding set occ. Vertical Fenestrations.,° lNon -Metal Iiik i i set occ.i 1 I Non -Metal Frame set occ. [Metal, fixed 1 { set occ. Metal Frame, Fixed set occ. O. o Ts ) 2 1 set occ.. Metal Frame, Operable set occ. MB entrance ! 1 ' I set occ. Metal Entrance Door set occ. 0 Y c LAII Types Iiilt set occ.! All types set occ. TO COMPLY - The Proposed Total UA shall not exceed the Target Total UA. Page 2 Subtotal Page 1 Subtotal Project Total rea UA Z 34Eb Area UA 254 Lzte, q 3M -to 1t0b.�` S140 12Bl :RG Component Performance Compliance (UA) Note 1- If vertical fenestration or skylight area exceeds maximum allowed per C402.4.1, then Target Area Adjustment of all applicable envelope elements will be calculated automatically by the compliance form. Refer to Target Area Adjustments worksheet for this calculation. Note 2 - Opaque assembly U -factors shall come from Appendix A or calculated per approved method as specified in C402.1.5.1. Note 3 - Proposed CMU mass wall in non -Group R that meet Table C402.1.4 Footnote D requirements can enter the target U -value of 0.014 Note 4 - For semi -heated spaces utilizing the wall insulation exception, enter Target Wall U -factors under Proposed Wall U -factors so exterior walls are neutral to the calculation. Note 5 - Mass transfer slab edges must be covered with an assembly having an overal U -factor of 0.2. Note 6 - Demising walls, doors, and vertical fenestration separating spaces with different degrees of space conditioning (unconditioned, semi -heated, fully conditioned) shall be included only on the ENV -UA form for the space with the greatest degree of space conditioning. Note 7 - List Group R above grade mass walls here. List all other mass walls, Commercial and Group R, in the Opaque Walls - Above Grade section. Note 8 - Slab -on -grade F -Factors shall come from Appendix A or calculated per approved method as specified in C402.1.5.1. Note 9 - Opaque door U -factors shall come from Appendix A or calculated per approved method as specified in C402.1.5.1. A door is defined as opaque if less than 50% of the door area has glazing. Note 10 - Fenestration assembly LI -Factors shall be the manufacturer's NFRC product rating, which includes the glazing and frame, or shall be the default value per Section C303.1.3. c U t.%) 10°6 Building Permit Plans Checklist, pg. 1 ENV -CHK 2015 WSEC Compliance Forms for Commercial Buildings including R2, R3, & R4 over 3 stories and all R1 Revised Jun 2016 Project Title: Date It .t The following information is necessary to check a building permit application for compliance with the building envelope requirements in the Washington State Energy Code, Commercial Provisions. Applicability (yes,no,na) Code Section Component Compliance information required in permit documents Location in Documents Budding Department Notes SCOPE 1C402.1.1 iprovisions Low energy spaces Low energy spaces are identified on plans; include project information, and calculations if applicable, that demonstrate spaces are eligible for envelope exemption i Q "11 C402.1.1.1 Semi -heated spaces 5emt-heated spaces are identified on plans, Include calculations that demonstrate spaces are eligible for wall insulation exemption ��V.Q �W � It* C402.1.2 Equipment Buildings Provide building area, average wall and roof U -factor, and installed equipment information that demonstrates equipment building is eligible for envelope provision exemption C410.2 Walk-in and warehouse cooler and freezer spaces Cooler and freezer spaces are identified on plans; C410 envelope compliance forms provided (pending) C101.4.1 Mixed occupancy Spaces with different occupancy requirements are identified on plans I C503.2 Change of space conditioning Existing unconditioned spaces changing to semi -heated or conditioned space, and existing semi -heated s(iaces changing to conditioned space, are identified on plans. Include calculations that demonstrate baseline and final level of conditioning. 01 C505.1 Change of occupancy Existing F, S and U -occupancy spaces undergoing a change in occupancy complies with the current WSEC. are indicated on plans; include calculations that demonstrate upgradetl ` ` 1 IrZ Pre -2002 Group R spaces undergoing a change to a commercial occupancy are indicated on plans; include calculations that demonstrate upgrade complies with the current WSEC. Non -Group R occupancy spaces undergoing a change to Group R are Indicated on plans; include calculations that demonstrate upgrade complies with the current WSEC. ENVELOPE PROVISIONS 4 C103.2 C103.6.3 Compliance documentation Indicate envelope insulation compliance path and provide applicable forms; ENV -PRESCRIPTIVE or ENV -UA / ENV-SHGC for component performance If complyingvia total buidlingT-1117. performance, provide a list of all proposed envelope component types, areas and U -values 1 C303.1.1 C303.1.2 Insulation identification Indicate identification mark shall be applied to all insulation materials and insulation installed such that the mark is readily observable during inspection "t'j I��� F 4/ 1. /� �J� C303.1.3 C402.4.3 Fenestration product rating Fenestration products shall be labeled with rated U -factor, SHGC, VT, and leakage rating 1/ C303.1.1 C402.2.1 General insulation installation Indicate installation methods, thicknesses, densities and clearances to achieve the intended R -value of all insulation materials; -r2...1 Where two or more layers of rigid insulation will be used, indicate that edge joints between layers are staggered 4/ C103.2 C402.2.2 Roof assembly insulation Indicate R-value(s) of cavity/continuous insulation on roof sections; .1 .20 Indicate framing materials on roof sections; Indicate method of framing for ceilings below vented attics and vaulted ceilings perA102.2 (std, adv); Provide area weighted average U -factor calculation for insulation whose thickness varies by 1 inch or less; Indicate effective U -factors of tapered insulation entirely above deck per A102.2.6; include roof configuration and slope, maximum R -value at peak and minimum R -value at low point for all roof surfaces Indicate R -values for thermal spacers and each insulation layer, and liner system (LS) method for metal building roofslikt C402.2.2 Skylight curb insulation Indicate curb insulation R -value on roof section if not included in skylight NFRC rating . e `'1 111 C103.2 C402.2.3 C402.2.4 C303.2.1 Above/below grade wall insulation Indicate R-value(s) of cavity/continuous insulation on wall sections; tin. Indicate framing materials on wall sections; Indicate method of framing for wood const per A103.2 (std, int, adv); Indicate material density category, wall weight and heat capacity for qualifying mass walls; For qualifying ASTM C90 masonry walls, indicate loose -fill core insulation material and percentage of cores filled including grouted cores, bond beams, vertical fills, headers and any other grouted cores; Indicate method of protection of exposed exterior basement/crawlspace wall insulation Building Permit 2012 Washington State Energy Plans Checklist, pg. 2 ENV-CHK Forms for Commercial Buildings including R2 & R3 over 3 stories and all R1 Code Compliance Project Title: Ilya& tea-itAt441,Date Applicability (yes,no,na) Code Section Component Compliance information required in permit documents Location in Documents Budding Department Notes C103.2 C402.4.4 Opaque doors Indicate rated U-factor (swinging) or R-value (non-swinging - roll-uplsliding) on wall sections or in door schedules - applies to doors with less than 50% glazed area "r '.I 4% C402.2.5 Floor over outdoor or unconditioned space insulation Indicate R-value(s) of cavity/continuous insulation on floor sections; Indicate framing material on floor sections; Indicate material density category and weight of qualifying mass floors plat C402.2.6 C303.2.1 Slab-on-grade floor insulation Indicate R-value of continuous insulation on wall section or foundation detail; ..11. s. ' Indicate insulation extends down vertically and/or horizontally the required distance from top of slab; Indicate method of protection of exposed exterior slab edge insulation ah() (� 1 0402.2.6 0303.2.1 Radiantly heated slab on-grade floor insulation Indicate R-value of continuous insulation on wall section or foundation detail; Indicate insulation extends down vertically from top of slab and then horizontally under the entire slab; Indicate method of protection of exposed exterior slab edge insulation 0402.2.8 Radiant heating system insulation Indicate insulation R-value behind radiant panels, U-bend/headers and bottom surface of radiantly heated floors (other than radiantly heated slab- on-grade) i, 0402.4.1 C502.2.1 C503.3.2 Vertical fenestration maximum area Provide calculation for total vertical fenestration area as a percentage of gross above grade wall area (WWR) for new construction, additions and alterations In ENV-SUM C402.4.1.1 C405.2.4.1 C502.2.1 0503.3.2 Increased prescriptive maximum vertical fenestration area with daylight zones and controls Provide calculations showing that the percentage of overall conditioned floor area within daylight zones is equal to or greater than 50% in 1 & 2 story builidngs: OR Provide calculations showing that the percentage of overall net floor area within daylight zones is equal to or greater than 25% in buildings 3 stories or more; include the gross floor area and list of spaces omitted for the net floor area; Note in envelope plans that all lighting fixtures located within daylight zones shall be provided with daylight responsive controls per WSEC Section 0405.2.4.1; indicate method of control in lighting fixture schedules Indicate that the VT of vertical fenestration is at least 1.1 times the rated SHGC C402.4.1.3 C502.2.1 C503.3.2 Increased prescriptive maximum vertical fenestration area with high-performance Indicate high performance U-factors and SHGC values in fenestration schedules; If applicable, provide area-weighted U-factor calculation(s) used for multiple fenestration elements within the same fenestration category per Table C402.3 4 0402.4.1.4 C403.6 Increased prescriptive maximum vertical fenestration area with DOAS mechanical systems Indicate that for eligibility, all occupied, conditioned spaces will be served by a dedicated outside air system (DOAS) that delivers ventilation air without requiring operation of the heating/cooling system per Section C403.6 C402.1.5 Wall/vertical fenestration target area adjustment Indicate if component performance with target area adjustment will be used to account for vertical fenestration area in excess of the prescriptive maximum allowed C402.4.1 C502.2.2 C503.3.3 Skylight maximum area Provide calculation for total skylight area as a percentage of gross roof area (SRR) for new construction, additions and alterations in ENV-SUM 0402.1.5.2 Roof/skylight target area adjustment Indicate if component performance with target area adjustment will be used to account for skylight area in excess of the prescriptive maximum allowed 0402.4.3itik. 0303.1.3 U-factors, SHGC and VT for all fenestration assemblies Indicate U-factors, SHGC and VT values in fenestration schedules; If applicable, provide area-weighted U-factor calculation(s) used for multiple fenestration elements within the same fenestration category per Table C402.3 Indicate if values are NFRC or default; if default then specify frame type, glazing layers, gap width, low-e coatings, gas-fill /t, ►'C 0402.4.3 Permanent shading devices For windows with overhangs or permanent projection shading devices, provide projection factor calculations (Equation C4-6) and associated minimum SHGC for north and non-north orientations Building Permit Plans Checklist, pg. 3 ENV-CHK Forms for Commercial Buildings including R2 & R3 over 3 stories and all R1 2012 Washington State Energy Code Compliance Project Title:U,"�� ai �.b ' - . �� Date 11.' ,lte Applicability (yes,no,na) ode Section Component Compliance information required in permit documents Location in Documents Building Department Notes l i I .H C402.4.2 Spaces in single story buildings requiring skylights In single story buildings, provide list of enclosed areas that exceed 2,500 sf, have ceiling height greater than 15 ft, and are space types required to comply with this provision. For each area identify space type, floor area, floor to ceiling height, and any exception taken; For each area provide calculations for percentage of conditioned floor area located within a daylight zone including skylight and eligible sidelight daylight zones; For each area provide calculations for percentage of skylight area, OR; Provide calculations for skylight effective aperture (Equation C4-5); Indicate haze factor of skylight glazing material or diffuser AIR LEAKAGE ire C402.5.1.1 Air barrier construction and sealing Indicate location of continuous air barrier on plans and sections; Provide details for all joints, transitions in materials, penetrations in air barrier and note method of sealing (caulked, gasketed, or other approved method) C402.5.3 Rooms containing open combustion fuel buming appliances used for space conditioning Indicate that room(s) containing non-direct vent appliances is isolated from inside the thermal envelope with a sealed air barrier, including doorway gasketing and sealing around ductwork and piping penetrations; Indicate insulation provided in wall, floor and ceiling of the room envelope, and insulation required on combustion air ductwork 0402.5.4 Access openings and doors to shafts, chutes, stairways and doors Indicate locations of all access openings and doors to shafts, chutes, stairways and elevators; Indicate method of gasketing, weatherstripping and sealing of these openings 0402.5.5 0403.2.4.3 Outdoor air intakes, exhausts and relief openings Indicate locations of all stairway enclosure, elevator shaft and building pressurization relief openings, outside air intakes and exhaust openings; Note in envelope plans that all relief, outside air intake and exhaust openings shall be provided with dampers in accordance with Mechanical Section C403.2.4.3 C402.5.8 Recessed lighting in building envelope Indicate method of sealing between light fixture housing and wall or ceiling; Note in envelope plans that all recessed lighting fixtures shall be IC rated and have an air leakage rating not greater than 2 cfm per ASTM E283 test; include these requirements in lighting fixture schedules C402.5.6 Loading dock seals Indicate weather seal at cargo and loading dock doors 0402.5.7 Vestibules Indicate locations and dimensions of vestibules and air curtains; Indicate exception and criteria utilized for all building entrances and exits that do not have a vestibule or air curtain; Indicate required performance for air curtains installed per exception 7; For unconditioned vestibules, indicate which envelope assembly (interior or exterior) complies with the requirements for a conditioned space y 0103.2 C402.5.1.2 Building air leakage test Indicate on plans the air barrier boundaries and area calculations on all six sides of the air barrier; Indicate air barrier test method in accordance with ASTM E779 or approved equivalent; Indicate required maximum leakage rate for compliance. Include the following requirements in project documents: (1) Submit air barrier test report to jurisdiction once test is completed; (2) If test results exceed 0.4 cfmtft2 at 0.3 in. wg, then visually inspect air barrier and seal noted sources of leakage; (3) Submit a follow-up report to jurisdiction noting corrective measures taken; (4) Include air barrier test report in compliance documentation provided to owner. If "no' is selected for any auestion. provide explanation: End of Building Permit Plans Checklist Jaiue for £'ement (Avg.) _ (U Sci d (Framing Rat o) + (Cava} Radc)2 Element: SKETCH OF ELEMENT Note: Make copies of this form for every building element. Framing Ratio (If applicable) ape ?A) o. G eitiv 1i r% a ( Thickness Materials (Inches) R / Inch Thickness R Value Solid R Value Cavity �� tlipi{Z, n.l2J 2}r til FV y� � f o,s(o F P tea __ . _,.. 4)1 wr I .Ula► oJ.. T2.2t rr 10, p,gv 5)1IIPIn 1141,Litltrtlowd 'FAQ 6)J / 4-1' � 7) lOve L¢. O.toI J) s) 10) 17)1 i i Total R Values /t d._.... U Value = 1/R 0.0 Average U Value Area of Element" 'Area of Element is net area after openings such as doors: windows and sytights have teen subtracted. ti Element_,�,,__ _ SKETCH OF ELEMENT Note: Mahe copies of Ibis form for every building element. framing Ratio (it applicable) = pair) I%5aIb-,L, --trw--uplazo MaterialThickness inches R/In Thickness R Value Solid R vela Cavtj .. • 12. d. J s p et9 q b(.p . . Mir 9ru 12 air1100 Utl____ l q IV 11' --rriA ur • . Summation R Values 2411 11 Value for Element (Avg.) Area of Element" _ * Area of Element is net a ea atter openings such as doors, windows arid skylights have been subtracted, Element: 061414412 SKETCH OF ELEMENT Note: Make copies of this form for every building element. Framing Ratio (if applicable) s. oug7 A161.• te0.19tiC. eitz19 MaterialThickness Inches R/In Thickness R Value Solid R value Cavity LL-- Vi- t bJ - -- IJI 1 V. Z.. 1. ' if�ti aePot .(p1 . Summation R Values 0-1 U=1/R -.6p U Va'ue for Element (Avg.) Area of Element" Area of Element is net a'ea after openings such as doors, windows and skylights have been subtracted. Lighting Summary LGT-SUM 2015 Washington State Energy Code Compliance Forms for Commercial Buildings including R2, R3, R4 over Project Info Compliance forms do not require a password to use. Instructional and calculating cells are write- protected. Project Title: vuze. isota;e Date If. t.tb- Applicant Information. Provide contact information for individual who can respond to inquiries about compliance form information provided. For Budding Department Use Company Name: Company Address: . 7 * ' Applicant Name: sa D iHIW REVIEWED FOR 4fODE COMPLIANCE 1-A',062L,3OV D Applicant Phone: /0&) , 3 . BeiQ,� Applicant Email: �1elj a 4 lie hte4 rtk • COW , Project Description p g(� Alteration ❑ New Building 0 Addition n1lni' �fti���� Include PROJ-SUM form (included in envelope forms workbook) wilt lighti Illfee f Building Additions Refer to Section C502.2.6for additional requirements. Compliance Method Lighting systems in addition area comply with all applicable provisions as a stand alone new construction project - -- ------ - - - .. ..___ .------�U Lighting systems in addition are combined with existing building lighting systems to demonstrate compliance Addition is combined with existing: For interior lighting projects, include new + existing interior lighting Wattage table in LTG -INT -BLD or LTG -INT -SPACE form. For exterior lighting projects, include new + existing exterior lighting Tradable and Proposed Non -Tradable Lighting Wattage tables 1 t¢rior lighting Exterior lighting o Cityof Tukwila ��.1t,.� - ,•Ei M fixture wattage in Proposed Lighting fixture wattage in Proposed in LTG -EXT form. Interior and Exterior Lighting Alterations Select all Lighting Power and Lighting Control elements that apply to the scope ofn9 the retrofit project. if project includes a combination of spaces where less than 50% of the existing fixtures are replaced in some spaces, and 50% or more of the ores are in others, then provide areplacedpla i no power compliance forms for the two retrofit conditions. Spaces undergoing the same type of retrofit may be combined into one lighting power compliance form. Refer to Section C503.6 for additional requirements. alteration lighting controls shall be commissioned per C408.3. 0 No changes are being made to the interior or exterior lighting systems and existing space uses and configuration are not changed. Lighting Power Interior lighting Parking garage Exterior lighting 50% or more of existing are replaced 0 0 Less than 50% of existi are re la P ced 0 --- - 0 ❑ 0 0 Lamp and/or ballast replacement only —; existing total wattage not increased 0 50% or more replaced - Total lighting power of new + existing LPA per Sections C405.4.2 and C405.5.2. Include new + existing Lighting Wattage table in LTG-iNT-SLD, LTG -INT -SPACE or LTG Less than 50% replaced - Total lighting power of new + existing total lighting power prior to alteration. Include new + existing -to Wattage table in LTG -INT -BLD, LTG -INT -SPACE or LTG -EXT 50% threshold applies to number of luminaires for interior spaces installed wattage for exterior luminaires. _ _ -to -remain fixtures shall comply with total -to -remain fixtures in Proposed -EXT form. -to -remain fixtures shall not exceed the -remain fixtures in the Proposed Lighting form. and parking garages, and total Lighting Controls Interior lighting g New wiring installed to serve added .�( fixtures and/or fixtures relocated to new ' ;4 circuit(s) Parking garage Exterior lighting 0 ■ 0 0 New or moved lighting panel ■ Interior space is reconfigured - 0 luminaires unchanged or relocated only New wiring or circuit - For interior lighting, provide required manual controls per C405.2.3, occupancy sensor controls per C405.2.1, daylight responsive controls per C405.2.4 and application specific lighting controls per C405.2.5. For exterior lighting, provide required controls per C405.2.7. New or moved panel - Provide all applicable lighting controls as noted for New Wiring and automatic time switch controls per C405.2.2. Reconfigured interior space - Provide all required lighting controls that apply to a new interior space. Application specific lighting control provisions per C405.2.5 do not apply to reconfigured spaces. Change of Space Use lit T` Existing interior lighting systems in areas under -going a change in space use are upgraded to comply with LPAs for the new space types per Tables C405.4.2(1) or C405.4.2(2). Identify interior spaces requiring LPD upgrade to the current Code in Proposed Lighting Wattage table in LTG-iNT-BLD or LTG -INT -SPACE form. RFPFIVFn bLO32S CITY OF TUKWILA NOV 2 9 2016 PERMIT CENTER Lighting Summary, cont. LGT-SUM 2015 Washington State Energy Code CompFenoe Forms for Comnerdal Bulidings indudmg R2 R3 R4 over Project Title: Y U go YJt GV IV « - - 'Date 1l . 28 . i • . Interior Lighting System Description 1fE W. etegfi by rtubegroAststi 1115 u. Oft ti t Stift VeCe oaD nwGott' Rtx % kisp 14e9/ i x 2' 2.-)U a 'er rt uo¢F ut fbagEfli Interior Lighting Power Allowance Method 0 Building Area Method lE Space-by.,pace Method Select method used m project. Interior Lighting Controls 71 An caos.2.1- 0405.2.8 controls ■ C405.2 Exception 5 Luminaire Level Lighting Control (IILC) ❑ Additional Efficiency Package Option C406.4 Enhanced digital lighting controls To comply with C408.4, no less than 90% of the total installed interior lighting power shall comply with the • required controls per C406.4. Dwelling Unit Interior Lighting ��'i77j'C ' Permanently installed Interior lighting foctwes >n dweNng wits comply with: pp 0 C405.2 thru C405.5 Commercial lighting Controls and LPA 0 C406.3 High Eflic a y Lighting O Exterior Lighting System Description '31'c j Interior Lighting - Space -By -Space Method 2015 Washington State Energy Code Compliance Forms for Commercial Buildings including R2, R3, R4 over 3 stories and all R1 Project Title: �V1 LDS `E6►/.J ► I r t r,r . r_ LTG -INT -SPACE Revised August 2016 • ......-.., , sows .,w..w•r.,©, Date R. Zj.np Calculation Area NOTE 9 0 0 Addition - 0 Addition stand alone • + existing 0 Spaces where < 50% of (-) Spaces where a 50% of 0 luminaires are replaced luminaires are replaced For Building Department Use LPA Calculation Type a Standard 0 Additional Efficiency Package Option 0 C406.3 Reduced Interior Lighting Power To comply with C406.3, the Proposed LPD shall be 25% lower than the Target LPA. Refer to C406.3 for additional requirements. Maximum Allowed Lighting Wattage NOTE' Location (plan #, room #) Space Type Ceiling Height NOTE 2 Gross Interior Area in ft2 Allowed Watts per ft2 Watts Allowed (watts/ft2 x area) Total Area r ...... Retail Display Allowance from LTG -INT -DISPLAY Lobby Art/Exhibit Display Allowance from LTG -INT -DISPLAY NOTE sI + Allowed Watts (Q Proposed Lighting Wattage NOTE 3 Location (plan #, room # Fixture Description NOTE 4, 5, 6 2'X'4' 'rGF ,cro 4.119eost 'x2? -14:726ftftlr Number of Fixtures tZ Watts/ Fixture NOTE 7 rob Goly Watts Proposed ttx1CP Proposed Retail Disp ay Lighting from LTG -INT -DISPLAY Total Proposed Watts may not exceed Total Allowed Watts for Interior Lighting Total Proposed Watts' 14y z. (Interior Lighting Power Allowance Note 1 - List all unique space types per Table C405.4.2(2) that occur in the project scope. Select space type category per from drop down menu. Note 2 - Indicate ceiling height for atriums and spaces utilizing the ceiling height adjustment per Table C405.4.2(2), Footnotes d thru f. Note 3 - List all proposed lighting fixtures including exempt lighting equipment and existing -to -remain fixtures. Note 4 - For proposed Fixture Description, indicate fixture type, lamp type (e.g. T-8), number of lamps in the fixture, and ballast type (if included). For track lighting, list the length of the track (in feet) in addition to the fixture, lamp, and ballast information. Note 5 - For lighting equipment eligible for exemption per C405.4.1, note exception number and leave Watts/Fixture blank. Note 6 - Existing -to -remain fixtures shall be included in the Proposed Lighting Wattage table in the same manner as new fixtures. Identify as existing in fixture description. Note 7 - For proposed Watts/Fixture enter the luminaire wattage for installed lamp and ballast using manufacturer or other approved source. For luminaires with screw-in lamps, enter the manufacturer's listed maximum input wattage of the fixture (not the lamp wattage). For low voltage lighting, enter the wattage of the transformer. For line voltage track/busway systems, enter the larger of the attached luminaire wattage or 50 watts/lineal foot, or enter the wattage limit of permanent current limiting device. Note 8 - Lobby Art/Exhibit Display Allowance is independent of the Maximum Allowed Lighting Wattage. Note 9 - Calculation Area Details: a. Lighting fixtures in a building addition may comply as a stand alone project, or they may be combined with the overall existing building lighting systems to demonstrate compliance. Refer to C502.1. Lighting, Motor, and Electrical Permit Checklist, Pg. 1rmRevised August LTG -CHK HK 2015 Washington State Energy Code Compliance Fos for Commercial Buildings including R2, R3, R4 over 3 stories and all R1 2016 (Date 5. j•�(Q Project Title: itwattt .--Vat opL61 The following information is necessary to check a permit application for compliance with the lighting, motor, and electrical requirements in the I Building Uepartment Notes Washington State Energy Code, Commercial Provisions. Applicability (yes,no,na) `Code Section Component LIGHTING CONTROLS C405.2 LCompliance information required in permit documents Location in Documents Lighting controls, general For all lighting fixtures, indicate lighting control method on plans for spaces and lighting zone(s) served, or exception taken ul� C405.2 C405.1 Luminaire level lighting controls (LLLC) Lighting in dwelling units C405.2.3 C405.2.1.1 C405.2.2.2 C405.2.4 C405.2.5 C405.2.2.1 Manual interior C405.2.2.2 Manual controls Indicate on plans all fixtures provided with LLLC in lieu of C405.2 lighting controls; provide description of control capabilities and performance parameters For permanently installed lighting fixtures in dwelling units, indicate lighting control method on plans for spaces and lighting zone(s) served, or demonstrate compliance with high efficacy exception Indicate on plans the method of manual lighting control (whether combined with occupancy sensor, automatic light reduction, daylight responsive or specific application controls), location of manual control device and area or specifice application it serves Indicate on plans which method of manual 50% lighting load reduction is provided, or whether lighting load is reduced via C405.2.3 """"t' ,,,,.."— occupancy sensors Lt C405.2.2 Method of automatic shut-off control Indicate on plans the method of automatic shut-off control during unoccupied periods (occupancy sensor or time switch) for all lighting zones;, Indicate locations where automatic shutoff is provided by other methods (occupancy sensor or digital timer switch) or which time switch control exception applies h TT.. C405.2.1 C405.2.1.1 Occupancy sensor controls Indicate on plans the spaces served by occupancy sensors; Indicate whether occupancy sensor controls are configured to be manual -on, automatic 50% -on, or serve a space eligible for automatic 100% -on per exception — A M C405.2.1.2 Occupancy sensor controls - warehouses Indicate aisleways and open areas in warehouse spaces provided with occupancy sensor controls that reduce lighting power by 50% C405.2.6 Digital timer switch Indicate required digital timer switch control function when control is used C405.2.2.1 Automatic time switch controls Indicate locations of override switches on plans and the lighting zone(s) served, include area sq. ft. 0405.2.4.2 0405.2.4.3 Daylight zones - Sidelight and toplight Indicate primary and secondary sidelight daylight zone areas on plans, include sq. ft.; Indicate toplight daylight zone areas on plans, include sq. ft.; For small vertical fenestration assemblies (rough opening less than 10 percent of primary daylight zone) where daylight responsive controls are not required, provide fenestration area to daylight zone calculation(s) C405.2.4 Daylight responsive controls Indicate on plans lighting zone(s) served by daylight responsive controls; Identify sidelight and toplight daylight zones that are not provided with daylight sensing controls and the exception(s) that apply;_ _ Indicate on plans the lighting load reduction method - continuous dimming, or stepped dimming that provides at least two even steps between 0%_100% of rated power; Indicate that daylight sensing controls are configured to completely shut off all controlled lights in the lighting zone C405.2.5 Additional controls Specific application lighting controls Identify spaces and lighting fixtures on plans that require specific application lighting controls per this section C405.2.5 - Items 182 Display and accent lighting Indicate on plans that display and accent lighting, and display case lighting are controlled independently from both general area lighting and other lighting applications within the same space; Indicate manual and automatic lighting control method TG -CHK Lighting, Motor, and Electrical Permit Checklist, Pg. 2 LRevisedAug HK3 2015 Washington State Energy Code Compliance Forms for Commercial Buildings including R2, R3, R4 over 3 stories and all R1 �y Q AVL/ Date "+ Z '— l (Q Project Title: �GN� � �d! The following information is necessary to check a permit application for compliance with the lighting, motor, and electrical requirements in the Washington State Energy Code, Commercial Provisions. Applicability (yes,no,na) ul� Code Section C405.2.5 - Item 3 Component Compliance information required in permit documents Hotel/motel guest rooms C405.2.5 - Item 4 Supplemental task lighting Indicate method of automatic control - vacancy or captive key control of all installed luminaires and switched receptacles in quest room Location in Documents Budding Uepartment Notes Indicate method and location of automatic shut-off vacancy control for supplemental task lighting, including under -shelf or C405.2.5 - Item 5 Lighting for non - visual applications C405.2.5 - Item 6 Lighting equipment for sale or demonstration C405.2.5 - Item 7 Means of egress lighting under -cabinet Iig_hting Indicate on plans eligible non -visual lighting applications, include sq. ft. area of each lighting control zone; _ Indicate on plans that non -visual lighting are controlled independently from both general area lighting and other lighting applications within the same space; Indicate method of manual lighting control and applicable automatic lighting control Indicate on plans that fighting equipment for sale or demonstration are controlled independently from both general area lighting and other lighting applications within the same space; r - Indicate method of manual lighting control and applicable automatic lighting control Identify on plans egress fixtures that function as both normal and emergency means of egress illumination; Provide calculation of lighting power density of total egress lighting; If total egress lighting power density is greater than 0.02 W/sq. ft., indicate on plans egress fixtures requiring automatic shut-off during unoccupied periods; Indicate method of automatic shut-off control Indicate on exterior lighting plans and fixture schedules the automatic lighting control method, control sequence, and locations served;— For building facade and landscape lighting, indicate automatic controls shut off lighting as a function of dawn/dusk and fixed opening/closing time; For all other exierior lighting, indicate automatic controls shut off lighting as a function of available daylight; include control sequence that also reduces lighting power by at least 30% between 12am-ham, or from 1 hour after dosing to 1 hour before opening, or based upon motion sensor For building grounds fixtures greater than 100 watts, indicate on plans whether fixtures have efficacy greater than 80 lumens or; are controlled by motion sensor, or are exempt lighting per C405.5.2 Indicate location(s) of master control switch(es) intended to control multiple independent switches; circuit breaker may not be used as a master control switch; Verify that no 20 amp circuit controlled by a single switch or automatic control is loaded beyond 80% C405.2.7 Exterior lighting controls C405.5.1 Exterior building grounds lighting controls C405.2.5 Area controls - Master control switches and circuit power limit C406.4 Enhanced digital lighting controls To comply with additional efficiency package option, indicate on plans all interior lighting fixtures that are individually addressed and provided with continuous dimming, or exception taken; C405.13 C408.3 Lighting system functional testing Include calculation of percent total installed interior lighting power that is configured with required enhanced lighting control functions (min 90% to comply with additional efficiency package option) If claiming lighting system commissioning exemption provide supporting calculation; Identify applicable commissioning documentation requirements per Section C408 or eligibility for exception; Provide written procedures for functional testing of all automatic controls and describe the expected system response 1 'cal Permit Checklist, P.. 3 LTG -CHK likallialiallealilifillidliabiliffillEr 2015 Washington State Energy Code Compliance Forms foruCommercial Buildings including R2, R3, R4 over 3 stories and all R1 Revised August 2016 `(a Project Title: .11406.• t I v al % Date ,. • The following information is necessary to check a permit application for compliance with the lighting, motor, and electrical requirements in the Washington State Energy Code, Commercial Provisions. Applicability (yes,no,na) Code Section Component Compliance information required in permit documents — Location in Documents Buildinguepartment Notes INTERIOR LIGHTING POWER & EFFICACY Include all luminaires in lighting fixture schedule; indicate fixture types, lamps, ballasts, and manufacturer's rated watts per fixture; C405.4.1 Total connected Identify spaces eligible for lighting power exemption on plans and in compliance forms; indicate the exception applied; 1-1i.bir C405.4.1 C405.4.2 interior lighting power Identify lighting equipment eligible for lighting power exemption in fixture schedule and in compliance forms; indicate the applied; exception _ _ Indicate that exempt lighting equipment is in addition to general area lighting and is controlled independently ii 0405.3 Exit signs Indicate location of exit signs on plans and rated watts per fixture in lighting fixture schedule (maximum 5 watts per fixture) �n L� 11.1.1 C405.1 Lighting in dwelling units -lamp efficacy If high efficacy exception is applied to permanently installed lighting fixtures in dwelling units, indicate in lighting fixture schedule if lamps in fixtures are high efficacy per R404.1. Calculate percentage of fixtures with high efficacy lamps in project (min 75% to comply with exception). ilibt 0406.3 Reduced lighting power density - dwelling unit tamp efficacy For project with dwelling units, to comply with additional efficiency package option indicate in lighting fixture schedule if lamps in fixtures have efficacy rating of 60 lumens per watt or more. Calculate percentage of fixtures with lamps that have this efficacy rating (min 95% to comply with option). Lighting Power Calculation - Indicate compliance path taken IV1 ( p C405.4.2.1 Building Area Method Complete required compliance forms — proposed wattage per building area does not exceed maximum allowed wattage per building area. Identify locations of building areas on plans 0405.4.2.2 Space -By -Space Method Complete required compliance forms — total proposed wattage does not exceed maximum allowed wattage. Identify locations of space types on plans, including retail display areas, lobby art & exhibit display areas, and ceiling heights as applicable / !/ l j� 0406.3 Reduced lighting power density To comply with additional efficiency package option, demonstrate in compliance forms that total connected interior lighting wattage is 75% less than the total maximum allowed lighting wattage via Building Area Method or Space -By -Space Method EXTERIOR LIGHTING POWER & EFFICACY Include all luminaires in lighting fixture schedule; indicate fixture types, lamps, ballasts, and manufacturer's rated watts per fixture; ( [IlC405.5.2 ls. Total connected exterior lighting Identify exterior applications eligible for lighting power exemption on plans and in compliance forms; indicate exception applied; power Indicate that exempt exterior lighting is controlled independently from non-exempt exterior lighting; include exception claimed for each fixture or group of fixtures under exception category Table C405.5.2(1) Exterior lighting zone Indicate building exterior lighting zone as defined by the AHJ C405.5.1 Exterior building grounds lighting For building grounds fixtures rated at greater than 100 watts that are complying based on efficacy, indicate rated lamp efficacy (in lumens per watt) in fixture schedule ••••.,"0405.5.2 Exterior lighting power calculations Complete required compliance form — proposed wattage for exterior lighting plus base site allowed does not exceed maximum allowed PERMIT COORD COPT PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: D16-0325 DATE: 11/29/16 PROJECT NAME: AVURE TECHNOLOGIES SITE ADDRESS: 4475 S 134 PL X Original Plan Submittal Revision # before Permit Issued Response to Correction Letter # Revision # after Permit Issued DEPARTMENTS: Building Division ill Public Works M"\ AVC, D --S—{ Fire Prevention 1 Structural Mt NP1 11116 Planning Division riPermit Coordinator 1 PRELIMINARY REVIEW: Not Applicable (no approval/review required) DATE: 12/01/16 Structural Review Required REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: Approved DUE DATE: 12/29/16 ❑ Approved with Conditions ❑ Corrections Required (corrections -ente�red in Reviews) Notation: C1 L.` Denied (ie: Zoning Issues) REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping 0 PW ❑ Staff Initials: 12/18/2013 City of Tukwila Allan Ekberg, Mayor Public Works Department - Bob Giberson, Director December 8, 2016 Realty Associates Fund X LP c/o Kidder Mathews 631 Strander Blvd., Suite G Tukwila, WA 98188 RE: Arvue Technologies Tenant Improvement 4475 S 134th St Permit Number: D16-0325 To Whom It May Concern: In accordance with Washington State Department of Health guidelines for Group A Public Water Systems, Public Works has implemented a cross -connection control program to protect the public water system from contamination via cross -connection. Since the project includes alterations to the existing plumbing system (fire sprinkler modifications), the entire plumbing system must be brought up to the current standards as set forth in the Uniform Plumbing Code including installation of an approved backflow prevention on the domestic, fire prevention and irrigation water supply lines to the building. The program requires elimination or control of any cross -connection between the distribution system and a consumer's water system by the installation of an approved backflow device. The City has determined that the building at the above address has deficiencies on the domestic water and fire prevention lines. a) Domestic Water A reduced Pressure Principle Assembly (RPPA) shall be installed immediately downstream of the existing 1.5" permanent water meter. Installation at another location requires the Public Works Director approval. The RPPA shall be installed in a HotBox/Rock or equal freeze protection enclosure. On your site plan, show the property lines, location of the domestic water meter and proposed RPPA location. Call out size/manufacturer/model number of the proposed RPPA and submit a backflow cut sheet. b) Fire Prevention Service The building shares two fire line connections. Both have a a non -testable check valve installed for backflow protection which needs to be replaced with a Detector Double Check Valve Assembly (DDCVA) that meets current requirements. Both Fire Department Connections (FDCs) need to have a Storz adapter with Knox Lock Box installed. Design shall be prepared by a Level III certificate of competency holder. FILE 6300 Building • 6300 Southcenter Boulevard Suite 100 • Tukwila, WA 98188 • 206-433-0179 Tukwila City Hall • 6200 Southcenter Boulevard • Tukwila, WA 98188 • 206-433-1800 • Website: TukwilaWA.gov Realty Associates Fund X LP December 8, 2016 Page 2 If you need assistance locating the above backflow deficiencies in the field, please contact Mr. Todd Reedy, Water Quality Specialist, Tukwila Water Department at (206) 571-6309. The Public Works Director will withhold issuance of the Avure Tenant Improvement Permit until a separate Public Works Type C Construction permit for the RPPA and DDCVA installation has been applied for. For a Type C permit, Public Works collects a base application and plan review fee ($250.00 plus 2.5% of construction cost for backflow installation and meter replacement). An additional 2.5% of subject construction cost will be assessed at the time of permit issuance. Applicant also has an option to post a bond or other financial guarantee for installation of the RPPA and DCVA in the amount equal to 150% of the design, installation and testing cost of the subject backflow, together with a letter confirming the installation in no more than 120 days. I have enclosed Public Works Bulletin C5 to help you. Please contact me at (206) 431-2440 or via email at Joanna.spencer@tukwilawa.gov or Mike Cusick, P.E., Public Works Water and Sewer Engineer at (206) 431-2441 if you have questions. Sincerely, Joanna Spencer Development Engineer JS:js enclosures: Public Works Bulletins # A1,-2,-9 and C5 Public Works Permit Application cc: David Kehle, Applicant Todd Reedy, Water Dept. Mike Cusick, P.E., PW Realty Associates Fund X LP, Owner (W:PW Eng/Other/Joanna Spencer/Letter Realty Associates 120816) Phone: 206-433-1800 • Email: Mayor@TukwilaWA.gov • Website: TukwilaWA.gov Joanna Spencer From: Todd Reedy Sent: Thursday, December 01, 2016 2:58 PM To: Joanna Spencer Subject: RE: Avure Technologies TI @ 4475 S 134th Place D16-0325 Hello Joanna, Regarding 4475 S 134th PI: -No RPPA On 1.5" domestic service. -This property is part of a Targe complex of buildings (Fostoria Park) with multiple owners that share two fireline connections. One at the south entrance on S. 134th and one at the northeast corner of the property. Both of the fireline connections just have a single -check valve for backflow prevention. Both fireline connections also need Storz adapters installed on the FDC's. The complex was part of a TI at the beginning of 2014 and nothing was done about the fireline connections. I remember meeting with Mike Cusick at the site so he will probably know more about what was decided to do about the deficiencies. -No irrigation connection on this service. Let me know if you have any questions, Todd From: Joanna Spencer Sent: Thursday, December 01, 2016 10:40 AM To: Todd Reedy <Todd.Reedy@TukwilaWA.gov> Subject: Avure Technologies TI @ 4475 S 134th Place D16-0325 Good Morning Todd, Are the backflows at this multitenant building current? Joanna Spencer Development Engineer Public Works Department 6300 Southcenter Blvd, Suite 100, Tukwila, WA 98188-2544 Phone: 206 431-2440 Fax: 206 431-3665 1 PRECISION BUILDERS INC Received by L&I Effective date 01/14/2002 01/19/2002 Expiration date Until Canceled Insurance Ohio Security Ins Co $1,000,000.00 Policy no. BKW55554018 Received by L&I Effective date 07/05/2016 07/15/2016 Expiration date 07/15/2017 Insurance history Savings No savings accounts during the previous 6 year period. Lawsuits against the bond or savings No lawsuits against the bond or savings accounts during the previous 6 year period. L&I Tax debts Page 2 of 2 No L&I tax debts are recorded for this contractor license during the previous 6 year period, but some debts may be recorded by other agencies. License Violations No license violations during the previous 6 year period. Workers' comp Do you know if the business has employees? If so, verify the business is up-to-date on workers' comp premiums. L&I Account ID Account is current. 471,890-00 Doing business as PRECISION BUILDERS INC Estimated workers reported Quarter 3 of Year 2016 "7 to 10 Workers" L&I account representative T1 / FEARAED FEROZE (360)902-4797 - Email: FERH235@Ini.wa.gov Workplace safety and health Check for any past safety and health violations found on jobsites this business was responsible for. © Washington State Dept. of Labor & Industries. Use of this site is subject to the laws of the state of Washington. Help us improve https://secure.lni.wa.gov/verify/Detail.aspx?UBI=600553713&LIC=PRECIBI151 C2&SAW= 12/30/2016 PRECISION BUILDERS INC Washington State Department of Labor & industries Home Espanol. Contact Safety & Health Claims & Insurance Page 1 of 2 Search L&I A -Z Index Workplace Rights PRECISION BUILDERS INC Owner or tradesperson Principals SANBURN, SCOT DEAN, PRESIDENT SANBORN, ELIZABETH ANNE, SECRETARY Doing business as PRECISION BUILDERS INC WA UBI No. 600 553 713 PO BOX 98609 DES MOINES, WA 98198-0609 206-878-2948 KING County Business type Corporation Governing persons LIZ SANBORN SCOT D SANBORN; License Verify the contractor's active registration / license / certification (depending on trade) and any past violations. Construction Contractor Active. Meets current requirements. License specialties GENERAL License no. PRECIB1151 C2 Effective — expiration 02/22/1985— 01/19/2018 Bond DEVELOPERS INS CO Bond account no. 415171 C $12,000.00 https://secure.lni.wa.gov/verify/Detail.aspx?UBI=600553713 &LIC=PRECIBI 151 C2&SAW= Help us improve 12/30/2016 BUILDING & SITE STATISTICS BUILDING COPE: IBC 2016 -ZONING: C/LI -TYPE OF CONSTRUCTION: V -B SPRINKLERED -OVERALL BUILDING FOOTPRINT: 29,181 F. -SITE AREA: 211,213 SF -TENANT AREA 11415 PERMIT OVERALL SPACE ' 3881 SP OFFICE MOO 891 SP FEW FACTORY(F): 1,452 OF WEE (81) : 1,544 eP OCCUPANCY GROUP: S -I, F 4 B TAX ID. #2613200084 PROJECT SCOPE CONSTRUCT NON IBEARIN G WALLS WITHIN EXISTING WAREHOUSE FOR NEW FACTORY ROOMS, INSULATE WALLS AND CEILING ABOVE NEW SUSPENDED CEILING, NEW LIGHTING. I-IVAC, ELECTRICAL AND SPRINKLER MODIFICATIONS UNDER SEPARATE PERMIT. PARKING: PARKING IS EXISTING, 119 STALLS, NO CHANGES BUILDING VALUATION: 12.0 MILLION PROJECT VALUATION: $ 43,560 LEGAL DESCRIPTION PARCEL 4: LOT 1 OF CITY OF TUKUJILA 51-1ORT PLAT NO. 19-26-S5, RECORDED UNDER RECORDING NO. 8004240503 AND ,4S AMENDED 5Y BOUNDARY LINE AGREEMENT RECORDED UNDER KING COUNTY RECORDING NO 8210010841 AND A5 AMEDED BY CITY OF TUKWILA BOUNDARY LINE ADJUSTMENT NO &-4-LA, RECORDED UNDER RECORDING NO 8607100861. PARCEL 5 AN EASEMENT 40' IN WIDTH IN INGRESS AND EGRESS AS SET FORT+ -1 IN SAID CITY OF TUKWILA BOUNDARY LINE ADJSTMENT NO 85-46-BLA BOTH SITUATE IN THE COUNTY OF KING, STATE OF WASHINGTON ENERGY CODE NOTES HEAT IS VIA GAS, NO ELECTRIC HEAT ALLOWED PROVIDE VAPOR ON ALL WALL TO THE WARM SIDE CAULK AND SEAL ALL OPENINGS TO OUTSIDE OR UNHEATED SPACES INCLUDING WEATHER-STRIPPING AT ALL EXTERIOR DOORS. MAXIMUM ALLOWABLE LOAD FOR SWITCH IS 80% OF 20 AMP CIRCUIT. PROVIDE DUAL LEVEL SWITCHING IN ALL ROOMS ADJACENT TO EXTERIOR WINDOWS TENANT AREA OF WORK BLDG. F REVIEWED FOR CODE COMPLIANCE APPROVED DEC 15 2016 City of Tukwila l BUILDING DIVISION Plan review approval is subject to errors and omissions. Approval of construction documents dons not auhoii? the violation of any adopted code or ordinance. Rr.. i .t of approved Field Co +y and,. ilions is . ckno edd. VICINITY MAP VICINITY MAP ISM ;`PPIT 4..i�itY] s. zQU11-'xED FOR: ���LWMochani �' CJEGtr1 b W'GasPiplee Cly of Tukwila BUI1 If G DIVISION City of Tukwi a BUILDING REVISIONS No changes shall be made to the scope of work tI'ithoi_.t prior approval of TtP,vna Building Division-. NOTE.: F•evisivinJ will require a neer plan submittal and may in,ude additional plan review fees. OVERALL SITE PLAN: SCALE: 1" = 50' RECEIVED DEC 01 2016 TUKWILA PUBLIC WORKS RECEIVED CITY OF TUKWILA NOV 2 9 2016 PERMIT CENTER 032.5 WASHINGTON DOOR SC14EDULE INSTALL LEVER HANDLE as, ALL DOORS El EX. 3'X1' WOOD AND GLASS DOOR WOOD JAMB, LOCKSET (INSIDE HANDLE 11JRNS FREELY FOR EXIT), CLOSER, THRESHOLD, WEATHERSTRIP E2 -E4 EX. 3'X1' SC WOOD DOOR, WOOD JAMB, LOCK SET, WALL STOP EX. 3'X1' SC WOOD POOR, WOOD JAMB, LATCHSET, CLOSER, THRESHOLD, E5 WEAHTERSTRIP E6,E1 EX. 37X1' SC WOOD DOOR, WOOD JAMB, PRIVACY LOCK EX. 3X1' H. MIL DOOR AND JAMB, LOCKSET (INSIDE HANDLE TURNS FREELYF ES RO EXIT), CLOSER THRESHOLD, WEAHTERSTRIP EX. 9'X10' OVERHEAD DOOR E9,EI0 DOOR SCHEDULE: NEU� TALL LEVER HANDLE CN ALL DOORS NIt43N4N1 NEW 31-0' X 11-0" SC OGD DOOR, WOOD JAMS, 11/2 34AOR BUTT$, L4-0421, WU. STOP, SILENCERS Nue* NEW 31-0" X 11-0' 6C WOOD DOOR, WOOD 46M13,1 1/2 PAIR BUTTS, LOCKEE1, CLOS , U EATHi TRIP (U431) ROOM SCHEDULE NO CHANGES TO EXSITING 5.1221tNEW VCT WE NEW ISR Mils GYP. BD. PAINTED (EE) =: PEW ACOUSTICAL CEILNCz TILE WITH CELNG GRID ABOVE MH I4SILA11GN (+9') 2 mos EX CONCRETE WITH SEALER • ICU RIMER GYP. BD. PAINTED (EE) NEW ACCUST1CAL MINS TILE WITH CEILNG GRID ABOVE WITH NIRLAT1CN 314 UM NEW SHEl t VINYL BM NEW 6' COVED SWEET VIM 41ALLI GYP. IID. PAINTED (EE) MEW ACOUSTICAL CEILI.6 TILE WITH CEL1NG MO ABOVE WITH mum on $ FL� EX COMTE WITH BALER ! moi NONE GYP. P. PANTED (EE) CE•1146 EXPOSED CONSTRUCTICIN TO N LLAT J ABOVE 1U4LL SCHEDULE A NEW 6")00GA 61EEL STUD AT 24' OG. TO MATED CEILING ABOVE, R -I0 CONTHJOUS 143610 NSLATION ON COLD SIDE, R-29 BATT INeiL ATION, VAPOR SAXER ON WAR 16IDE, 81b' GYP ED EACH SIRE. NEW 6" X20GA 61EEL6 /IV AT 24' OC. TO INSULATED CUM ABOVE, R-10 CCNTWOUs les4N8T EX. TILT UP CONCRETE, R-29 BATT ISILATICN, VAPOR BARRIER GH WAf I BCE, W GYP BD. C NEW 6' X20GA STEEL STUD At 241 O.C. TO ISW.ATED CELI16 ABOVE, 6CI110 MAIM $!8' GYP BD EACH NOE. LEGEND EXISTING WALL NEW STUD WALL EXISTING DOOR NEW DOOR (MATCH EXISTINCs) ENERGY CODE NOTES 1) NO CHANGE IN EXISTING HVAC 2) NO CHANGE N EX OFFICE ENVELOPE 3) NO CHANGE IN EX. OFFICE LIGHTING I f+cittotcl EXISTING OFFICE NO CHANGES FLOOR PLAN: NEW FLOOR SCALE: VS" • 1'-0" SINGLE EXIT, OCCUPANT LOAD UNDER 49 TRAVEL DISTANCE UNDER 100 LF EXISTING WAREHOUSE 22'-/_" EX FULL HEIGHT DEMISING WALL • / \\ REVIEWED FOR \ / EXISTING OFFICE NO CHAFES EXISTINGOFFIC \ NO CHANGES / CODE COMPLIANCE APPROVED DEC 15 2016 City of Tukwila BUILDING DIVISION T -2i" ®"�-- EX. RESTROOMS r�X NO NO CHANGE no EXISTING OFFICE NO CHANGES EXISTING OFFIC NO CHANGES EXISTINCs RAMP EN SI' -31" Jj D c` TY OF TUKWILA NUV 2 9 2016 PERMIT CENTER EXISTING OVERALL TENANT SPACE: 3,881 SF FLOOR PLAN: EXISTING/DEMO EEXXISTINNG WWAAREHOUSE: 28996 SF ((SI)96 OCC SCALE: VS l'-0" NEW 8Is EX. OFFICE NEW MANF. \\WKST-4\Docu CAD 8918F 03) 9 OCC 11462 8F (F)1 OCC 81)3 FOSTO • OSI 8 c co 11 * N 0 0 W 4 CL ti USI SS ' ARK\BUIL G B\T-1.dwg, T-1, 11/28/2016 8: FOR WALLS GREATER THAN 8'- 0" IN WIDTH WITHOUT AN INTERSECTING WALL, PROVIDE 12ga. WIRES SPLAYED a 45 TO AN EYE SCREW * ROOF AND TOP of WAL 11111111111M11111111111111111.1111r 11.1111I■u.Ilua, ATTACH TOP RUNNER TRACK TO CEILING GRID WITH 2 - N6 x I I/8" LONG SCREWS AT 2'-0" o.C. TYPICAL STUDS WALL PER SCND. (FOR WALL INSULATION SEE PLAN) 5/S" GYP. BD. EA. SIDE (FLUSH FINISH). SEE REFLECTEDAL CEILING PLAN Tl'P. UJALL TO REFLECTED CEILING SCALE: 1-1/2' a 1'-0" TYPICAL WALL FRAMING ATTACH BOTTOM TRACK TO CONC. FLOOR W/ POWDER DRIVEN ANCHORS,14ILTI OR APPROVED, 013I" DIA., 1" EMBEDMENT AT 24" O.C. SECTION 5/8" GYP. P. (TYPE 'X' 0 FIRE RATED WALLS.) ACOUSTICAL BLANKET 8 SOUND WALL. CONC. SLAB ON GRADE UJr4LL TO SLAB SCALE: 1-1/2' • 1'-0' CAULK GYP. 8D. TO FLOOR s ALL SOUND AND INSUL. WALLS SECONDARY SUSPENDED CEILING ABOVE ACOUSTICAL SECTION 2x4 WOOD STUD WALL (SEE SCHEDULE) 2x WOOD BLOCKING 2 1/2" WOOD CASING - STAINED 11/2" x WOOD JAMB - STAINED 5/8" x WOOD STOP - STAINED SOLID CORE WOOD DOOR STAINED 5/8" GYP BD. EACH SIDE UJOOD FRAME DETAIL SCALE: I-1/2' • I'-0" INTERIOR UJALL DETAIL SCALE: 1-1/2' • I'-0" CEILING 11'-0" 4, BATT INSULATION - R-30 CONTINUOUS W/ENERGY CALCS. TYP. OFFICE WALL FRAMING W/BATT INSULATION 6"x20 GA. STEEL STUDS 0 24" O/C 5/8" GYP. BD. BOTH SIDES SECTION SECTION EX. RLL HEIGHT DEMISING WALL NO CHANGES WALL BEYOND 2 0 0' EX. ROOF STRUCTURE NO CHANGES NEW WALL TYPE A INSULATED SECTION ,4-4 i- CONTINUOUS R-30 INSULATION IN SUSPENDED CEILING GRID XXXXXX XXXX XX XXXXXXX NEW SUSPENDED CEILING GRID WITH TILE AND LIGHTS NEW ALERGEN NEW ALERGEN SCALE: 1/4' • 1'-0" NEW WALL TYPE C SOUND INSULATED—\ XXXX NEW HALL EX. EXTERIOR TILT UP CONCRETE WALL NO CHANGES NEW WALL 1TFE B INSULATED �r SPACER BAR, OR OTHER SUITABLE SYSTEM, TO KEEP PERIMETER COMPONENTS FROM SPREADING APART 4 MIN. MIN. 2' UN -ATTACHED WALLS ANGLE NOTE: ATTACH CEILING AND GRID TO WALL ANGLE (MOULDING) AT TWO ADJACENT WALLS VIA POP RIVETS. 4 012 G4. WIRES WITHN 2" OF CROSS TEE CONNECTION ARRANGED AT 0' FROM EACH OTHER AND AT AN ANGLE NOT EXCEEDING 45'. LOCATE RESTRAINT PANELS AT 12' O.C. IN EACH DIRECTION AND WITHIN 6' OF EACH WALL. NOTES: NOTE: SUSPENSION WIRES TO BE 12 GAGE AT 4' 0.0. W/ ATTACHMENT DEVICES CAPABLE OF SUPPORTING 100 POUNDS. HANGER 4 PERIMETER WIRES MUST BE PLUMB WITHIN 1 IN 6 UNLESS COUNTER SLOPING WIRES ARE PROVIDED I) MAIN BEAMS TEES AND CROSS TEES MUST BE HEAVY DUTY W/ CONNECTION STRENGTHS OF 100 POUNDS IN COMPRESSION 4 TENSION. 2) CEILING AREAS GREATER THAN 1000 SF MUST HAVE LATERAL FORCE BRACING VIA DIAGONAL SPLAY WIRES, LIMITING MOVEMENT TO LESS THAN 1/4" AT POINT OF ATTACHMENT. 3) LIGHT FIXTURES TO BE POSITIVELY ATTACHED TO MAIN AND CROSS TEES. AND IF OVER 56! MUST BE INDEPENDENTLY SUPPORTED. 4) PARTITIONS GREATER THAN 6' TALL NEED fNDEPENDENT BRACING VIA SPLAY WIRES (SEPARATE FROM ANY OTHER WIRES). PARTITIONS 6' OR LESS NO ATTACHMENT 15 REQUIRED. 5) SPRINKLER IAD PENETRATIONS MUST HAVE 2" OVERSIZED TRIM TO ALLOW 1" MOVEMENT IN ALL DIRECTIONS. 6) MANUFACTURER CERTIFICATION OF COMPONENT PERFORMANCE AND PERIODIC SF'ECIAL INSPECTION OF ANCHOR SYSTEM IS REQUIRED. 1) FOR CEILING AREAS EXCEEDING 2500 SF, A SEISMIC SEPERATION JOINT OR FULL HEIGHT WALL. PARTITION THAT BREAKS THE CEILING SHALL BE PROVIDED. 8) ALL CROSS TEES SHALL BE CAPABLE OF CARRYING TI -E DESIGN LOAD WITHOUT EXCEEDING DEFLECTION EQUAL TOJMO OF ITS SPAN. 9) ALL WIRE TIES ARE TO BE THREE TIGHT TURNS AROUND ITSELF WITHIN 3 NCH. �, RESTRAINED CEILING DETAILS (MEETS IBC 2016 SEC 808 AND ,OSTM C 635 ASTM C 636 AND ASCE 1-02) SCALE LI6-4TINC GALL. 1,452 SF MANUFACTURING 0 111 WATTS PER SF = 1,612 WATTS ALLOWED • TOTAL WATTS INSTALLED ■ 1462 WATTS 21X4' x 37UI3E FI CU ESCENT RECESSED 12 AMU • LOU WATTS WITH ACRYLIC LIM®88 WATTS NO CHANGE TO LIGHTING. WAREHOUSE 0 Pl< a 14' 8'-6" WAREHOUSE NO CI-IANGE TO LIGHTING. 2'X1' X 2TUEE FLOURESSCENr RECESSED 6.66W . 396 WATTS WITH ACRYLIC LENS w 66 WATTS WALL SWITCH (MAX 80% OF 20 AP's CIRCUIT) WITH OCCUPANCY SENSOR CI EXISTING OFFICE NO CHANGES 101 E6 [Elo EXISTING OFFICE NO CHANGES EXISTING OFFICg E2 NO CHANGES EXISTING OFFIC, NO CHANGES El REFLECTED CEILING NEUJ SCALE: I/8" • 1'-0" 11WKST-41Documents1 JJ TYPES EX. RESTROOMS HC NO CHANGE REVIEWED FOR CODE COMPLIANCE APPROVED DEC 15 2016 City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA NOV 2 9 2016 PERMIT CENTER NEW HEATED SPACE 1,452 SF WITH SE • • CEILING WITH INSULATION ABOVE FOSTORIA BUSINESS PARK'BUILDING B\T- .dwg, T-2, 11/ 2018 8:55:29'P