Loading...
HomeMy WebLinkAboutPermit D16-0335 - RUBY THAI KITCHEN - TENANT IMPROVEMENTRUBY THAI KITCHEN 2600 SOUTHCENTER MALL FC -15 D16-0335 Parcel No: Address: City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-438-9350 Web site: httD://www.TukwilaWA.eov DEVELOPMENT PERMIT 9202470010 Permit Number: D16-0335 2600 SOUTHCENTER MALL FC15 Issue Date: 2/13/2017 Permit Expires On: 8/12/2017 Project Name: RUBY THAI KITCHEN Owner: Name: WESTFIELD PROPERTY TAX DEPT Address: PO BOX 130940 , CARLSBAD, FL, 92013 Contact Person: Name: MOSAD ELEWA Address: 3386 CLARINE WAY W , DUNEDIN, FL, 34698 Contractor: Name: LARRY MORRISON CONSTRUCTION INC Address: 2204 1/2 186 AVE E , SUMNER, WA, 98390 License No: LARRYMC980DN Lender: Name: IRG INC Address: ONE HARBOUR PLACE , TAMPA, FL, 33602 Phone: (813) 245-6554 Phone: (253) 862-7373 Expiration Date: 5/13/2018 DESCRIPTION OF WORK: TENANT IMPROVEMENTS TO AN EXISTING RESTAURANT SPACE INCLUDING ARCHITECTURAL, ELECTRICAL, MECHANICAL AND PLUMBING Project Valuation: $89,000.00 Type of Fire Protection: Sprinklers: YES Fire Alarm: YES Type of Construction: IIB Electrical Service Provided by: TUKWILA Fees Collected: $2,378.80 Occupancy per IBC: B Water District: TUKWILA Sewer District: TUKWILA Current Codes adopted by the City of Tukwila: International Building Code Edition: International Residential Code Edition: International Mechanical Code Edition: Uniform Plumbing Code Edition: International Fuel Gas Code: 2015 2015 2015 2015 2015 National Electrical Code: WA Cities Electrical Code: WAC 296-46B: WA State Energy Code: 2014 2014 2014 2015 Public Works Activities: Channelization/Striping: Curb Cut/Access/Sidewalk: Fire Loop Hydrant: Flood Control Zone: Hauling/Oversize Load: Land Altering: Landscape Irrigation: Sanitary Side Sewer: Sewer Main Extension: Storm Drainage: Street Use: Water Main Extension: Water Meter: Volumes: Cut: 0 Fill: 0 Number: 0 No Permit Center Authorized Signature: LOA Date: I hearby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local lawsregul.-._-' onstruction or the performance of work. I am authorized to sign and obtain this developm- . . - - • • ee to the conditions attached to this permit. Prin 4006... . lippl iii.La /764•i/ iv/(/& Signa Date: 2" 215/7 This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: ***BUILDING PERMIT CONDITIONS*** 2: Work shall be installed in accordance with the approved construction documents, and any changes made during construction that are not in accordance with the approved construction documents shall be resubmitted for approval. 3: All permits, inspection record card and approved construction documents shall be kept at the site of work and shall be open to inspection by the Building Inspector until final inspection approval is granted. 4: All construction shall be done in conformance with the Washington State Building Code and the Washington State Energy Code. 5: All food preparation establishments must have Seattle/King County Department of Public Health sign -off prior to opening or doing any food processing. Arrangements for final Health Department inspection shall be made by calling Seattle/King County Department of Public Health, (1-800-325-6165 ext 9-566), at least three working days prior to desired inspection date. On work requiring Health Department approval, it is the contractor's responsibility to have a set of plans approved by the agency on the job site. 6: Fire retardant treated wood shall have a flame spread of not greater than 25. All materials shall bear identification showing the fire performance rating thereof. Such identification shall be issued by an approved agency having a service for inspection at the factory. 7: There shall be no occupancy of a building until final inspection has been completed and approved by Tukwila building inspector. No exception. 8: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of this requirement. 9: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206-431-3670). 10: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center. 11: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 12: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431-3670). 13: A Type 1 hood shall be installed at or above all commercial cooking appliances and domestic cooking appliances used for commercial purposes that produce grease vapors. Each required commercial kitchen exhaust hood and duct system required by section 610 of the International Fire Code to have a Type 1 hood shall be protected with an approved automatic fire-extinguishing system installed in accordance with this code. (IFC 904.2.1 and IFC 904.11) Automatic fire-extinguishing systems shall comply with UL 300 or other equivalent standards and shall be installed in accordance with the requirements of the listing. (NFPA 96, 10.2.3)( KITCHEN HOOD FIRE SUPPRESSION SYSTEM TO BE MODIFIED AS NECESSARY TO PROVIDE PROPER COVERAGE FOR NEW COOKING EQUIPMENT/ARRANGEMENT.) 15: All new automatic fire-extinguishing systems and all modifications to existing automatic fire-extinguishing systems shall have fire department review and approval of drawings prior to installation or modification. 14: Portable fire extinguishers shall be provided within a 30-foot (9144 mm) travel distance of commercial-type cooking equipment. Cooking equipment involving vegetable or animal oils and fats shall be protected by a Class K rated portable extinguisher. (IFC 904.11.5) 19: Fire protection systems shall be maintained in accordance with the original installation standards for that system. Required systems shall be extended, altered or augmented as necessary to maintain and continue protection whenever the building is altered, remodeled or added to. Alterations to fire protection systems shall be done in accordance with applicable standards. (IFC 901.4) 17: Sprinklers shall be installed under fixed obstructions over 4 feet (1.2 m) wide. (NFPA 13-8.6.5.3.3) 16: All new sprinkler systems and all modifications to existing sprinkler systems shall have fire department review and approval of drawings prior to installation or modification. New sprinkler systems and all modifications to sprinkler systems involving more than 50 heads shall have the written approval of Factory Mutual or any fire protection engineer licensed by the State of Washington and approved by the Fire Marshal prior to submittal to the Tukwila Fire Prevention Bureau. No sprinkler work shall commence without approved drawings. (City Ordinance No. 2436). 21: Maintain fire alarm system audible/visual notification. Addition/relocation of walls or partitions may require relocation and/or addition of audible/visual notification devices. (City Ordinance #2437) 20: All new fire alarm systems or modifications to existing systems shall have the written approval of The Tukwila Fire Prevention Bureau. No work shall commence until a fire department permit has been obtained. (City Ordinance #2437) (IFC 901.2) 22: An electrical permit from the City of Tukwila Building Department Permit Center (206-431-3670) is required for this project. 25: The maximum flame spread class of finish materials used on interior walls and ceilings shall not exceed that set forth in Table No. 803.9 of the International Building Code. 26: Post address on storefront per approved Westfield standards. 18: Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (City Ordinances #2436 and #2437) 23: Any overlooked hazardous condition and/or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. 24: These plans were reviewed by Inspector 511. If you have any questions, please call Tukwila Fire Prevention Bureau at (206)575-4407. PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 1700 BUILDING FINAL** 1400 FIRE FINAL 0409 FRAMING 0606 GLAZING 0406 SUSPENDED CEILING CITY OF TUKWILA Community Development Department Public Works Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.TulcwilaWA.gov Building Permit No. 1(0— 0 33S Project No. Date Application Accepted: (d= Date Application Expires: (n --��—� 7 (For office use only) CONSTRUCTION PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **Please Print** SITE LOCATION Site Address: King Co Assessor's Tax No.: 600 SOUTHCENTER MALL, TUKILA, WA Suite Number: FC -15 Floor: Tenant Name: RUBY THAI KITCHEN New Tenant: m Yes PROPERTY OWNER Name: INNOVATED RESTAURANT GROUP, INC. Address: 777 S. HARBOUR ISLAND BLVD. City: TAMPA State: FL Zip: 33602 CONTACT PERSON — person receiving all project communication Name: MOSAD ELEWA Address: 3386 CLARINE WAY W City: DUNEDIN State: FL Zip: 34698 Phone: (813) 245-6554 Fax: (801) 218-6554 Email: MCREATIVEDESIGN@HOTMAIL.COM GENERAL CONTRACTOR INFORMATION Company Name: HIATT ARCHITECTURE CompanyName: r-A�e NJd� //l1(�S.�L Address: 4410 W MELROSE AVE. City: TAMPA State: FL Zip: 33629 Address�79 /1 646/0.__Cityn%(Q/4Slliiil6 Email: INFO@MCDART.NET State: �c Zip y//7 Phone:74 y 9.29 /s9.� Fax: State: Zip: Contr Reg No.: rife) Exp Date: Email: Tukwila Business License No.: 7-40 H:\ApplicationsWonns-Applications On Line\2011 Applications\Permit Application Revised - 8-9-1 I.docx Revised: August 2011 bh ❑ ..No ARCHITECT OF RECORD Company Name: HIATT ARCHITECTURE Architect Name: DAVID HIATT Address: 4410 W MELROSE AVE. City: TAMPA State: FL Zip: 33629 Phone: (813) 333-2717 Fax: (813) 289-3332 Email: INFO@MCDART.NET ENGINEER OF RECORD Name/ `G Company Name: Address: ,/1�,((OO /[dyi(/2 ger Engineer Name: City:'.7— - Stat./ Address: 62 City: State: Zip: Phone: Fax: Email: LENDER/BOND ISSUED (required for projects $5,000 or greater per RCW 19.27.095) Name/ `G Address: ,/1�,((OO /[dyi(/2 ger City:'.7— - Stat./ Zip: 3� 62 Page 1 of 4 BUILDING PERMIT INFORMATION — 206-431.3670 Valuation of Project (contractor's bid price): $ 6O/ 1(0 Describe the scope of work (please provide detailed information): TENANT IMPROVEMENTS TO EXISTING RESTAURANT SPACE INCLUDING ARCHITECTURAL, ELECTRICAL, MECHANICAL, AND PLUMBING. Existing Building Valuation: $ ,?OCJ, O SD . "' Will there be new rack storage? 0 Yes No If yes, a separate permit and plan submittal will be required. Provide All Building Areas in Square Footage Below PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact: Handicap: Will there be a change in use? ❑ Yes 0 No If "yes", explain: FIRE PROTECTION/HAZARDOUS MATERIALS: Sprinklers J Automatic Fire Alarm 0 None 0 Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? 0 Yes ❑ No If `yes', attach list of materials and storage locations on a separate 8-1/2" x 11 " paper including quantities and Material Safety Data Sheets. SEPTIC SYSTEM ❑ On-site Septic System — For on-site septic system, provide 2 copies of a current septic design approved by King County Health Department. H:\Applications\Forms-Applications On Line \201 I Applications\Permit Application Revised - 8-9-11.docx Revised: August 2011 bh Page 2 of 4 Existing Interior Remodel Addition to Existing Structure New Type of Construction per IBC Type of Occupancy per IBC 1st Floor 2"d Floor 599 3rd Floor Floors thru Basement Accessory Structure* Attached Garage Detached Garage Attached Carport Detached Carport Covered Deck Uncovered Deck PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact: Handicap: Will there be a change in use? ❑ Yes 0 No If "yes", explain: FIRE PROTECTION/HAZARDOUS MATERIALS: Sprinklers J Automatic Fire Alarm 0 None 0 Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? 0 Yes ❑ No If `yes', attach list of materials and storage locations on a separate 8-1/2" x 11 " paper including quantities and Material Safety Data Sheets. SEPTIC SYSTEM ❑ On-site Septic System — For on-site septic system, provide 2 copies of a current septic design approved by King County Health Department. H:\Applications\Forms-Applications On Line \201 I Applications\Permit Application Revised - 8-9-11.docx Revised: August 2011 bh Page 2 of 4 PUBLIC WORKS PERMIT INFORMATION .206433-4179: Scope of Work (please provide detailed information): N/A Call before you Dig: 811 Please refer to Public. Works Bulletin #1 for fees and estimate sheet. Water District ..• .Tukwila ❑ ... Water District #125 0 ...Water Availability Provided Sewer District ..• .Tukwila 0 ...Sewer Use Certificate ❑ .. Highline ❑...Valley View ❑ .. Renton ❑ ... Sewer Availability Provided ❑ .. Renton ❑ .. Seattle Septic System: ❑ On-site Septic System — For on-site septic system, provide 2 copies of a current septic design approved by King County Health Department. Submitted with Application (mark boxes which apply): ❑ ...Civil Plans (Maximum Paper Size — 22" x 34") ❑ ...Technical Information Report (Storm Drainage) ❑ ...Bond 0 .. Insurance 0 .. Easement(s) Proposed Activities (mark boxes that applv): ❑ ...Right-of-way Use - Nonprofit for less than 72 hours ❑ ...Right-of-way Use - No Disturbance ❑ ...Construction/Excavation/Fill - Right-of-way 0 Non Right-of-way ❑ ❑ ...Total Cut cubic yards 0 .. Work in Flood Zone ❑ ...Total Fill cubic yards ❑ .. Storm Drainage ❑ ...Sanitary Side Sewer 0 .. Abandon Septic Tank ❑ ...Cap or Remove Utilities 0 .. Curb Cut 0 ...Frontage Improvements ❑ .. Pavement Cut ❑ ...Traffic Control 0 .. Looped Fire Line 0 ...Backflow Prevention - Fire Protection ❑ .. Geotechnical Report 0 .. Maintenance Agreement(s) ❑ ... Traffic Impact Analysis ❑ ...Hold Harmless — (SAO) ❑ ...Hold Harmless — (ROW) ❑ .. Right-of-way Use - Profit for less than 72 hours ❑ .. Right-of-way Use — Potential Disturbance Irrigation " Domestic Water 0 .. Grease Interceptor ❑ .. Channelization 0 .. Trench Excavation ❑ .. Utility Undergrounding ❑ ...Permanent Water Meter Size... 99 WO # ❑ ...Temporary Water Meter Size .. 99 WO # ❑ ...Water Only Meter Size 99 WO # ❑ ...Deduct Water Meter Size ❑ ...Sewer Main Extension Public 0 Private 0 ❑ ...Water Main Extension Public 0 Private 0 FINANCE INFORMATION Fire Line Size at Property Line Number of Public Fire Hydrant(s) ❑ ...Water 0 ...Sewer Monthly Service Billing to: Name: ❑ ...Sewage Treatment Day Telephone: Mailing Address: City State Zip Water Meter Refund/Billing: Name: Mailing Address: Day Telephone: City State Zip H:1Applications\Forms-Applications On Line \2011 Applications\Permit Application Revised - 8-9-11.docx Revised: August 2011 bh Page 3 of 4 r• TAPPI Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUI : 'G O HOS AGENT: Signature:` Print N. i L Mailing Address: H:Wpplications\Forna-Applications On Line 12011 Applications\Permit Application Revised - 8-9-11.docx Revised: August 2011 bh Date: /2— I - I44.6 Day Telephone: ? — 929 - /5-9y 129 er5fi)i ' City 4/C _ 21'//zip7 state Page 4 of 4 Cash Register Receipt City of Tukwila DESCRIPTIONS 1 ACCOUNT 1 QUANTITY PermitTRAK PAID $1,470.98 D16-0335 Address: 2600 SOUTHCENTER MALL FC15 Apn: 9202470010 $1,470.98 DEVELOPMENT $1,401.15 PERMIT FEE R000.322.100.00.00 0.00 $1,396.65 WASHINGTON STATE SURCHARGE 8640.237.114 0.00 $4.50 TECHNOLOGY FEE $69.83 TECHNOLOGY FEE TOTAL FEES PAID BY RECEIPT: R10804 R000.322.900.04.00 0.00 $69.83 $1,470.98 Date Paid: Monday, February 13, 2017 Paid By: FRANK NIVER CONTRACTING LLC Pay Method: CHECK 1776 Printed: Monday, February 13, 2017 9:53 AM 1 of 1 CRWSYSTEMS Cash Register Receipt City of Tukwila DESCRIPTIONS ACCOUNT 1 QUANTITY I PAID PermitTRAK $907.82 D16-0335 Address: 2600 SOUTHCENTER MALL FC15 Apn: 9202470010 $907.82 DEVELOPMENT $907.82 PLAN CHECK FEE TOTAL FEES PAID BY RECEIPT: R9998 R000.345.830.00.00 0.00 $907.82 $907.82 Date Paid: Thursday, December 08, 2016 Paid By: FRANK NIVER CONTRACTING LLC Pay Method: CHECK 1770 Printed: Thursday, December 08, 2016 11:59 AM 1 of 1 SYSTEMS INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project: 3V T1 -14I T,y,Re of Inspection: oiviv, �1 . Ad�djr�es�s: L ccUTI.1661 WALL, Date Called: Special Instructions: fr ,-- 5 Date Wante i rt -i. Requester. Phone No: Approved per applicable codes. E Corrections required prior to approval. COMMENTS: Inspector: Date:5Ni7 REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION NO. INSPECTION RECORD Retain a copy with permit PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Projec: l ,q VIA Ty of Inspection: 64-Az/Az- Address: 26cD (.11740.4"672 iW'LL Date Called: Special Instructions: Date Wanted: 5lgi7 am.f-l p.m. Requester: Phone No: Approved per applicable codes. E] Corrections required prior to approval. CONI M ENTS: Inspector: Date: J C REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. Gar INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Pr ct: Type lrr5pection: Address: 2 Sgt./7)&01132 MALL Date Called: Special Instructions: Date Wanted:m e 9 % a. p.m. Requester: Phone No: Approved per applicable codes. Corrections required prior to approval. COMMENTS: Inspector: REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION NUMBER INSPECTION RECORD Retain a copy with permit DIGS-p33� /7 F-013 PERMIT NUMBERS CITY OF TUKWILA FIRE DEPARTMENT 206-575-4407 Project: (A-77)1 �! Sprinklers: L Type of Inspection: F; -e. �Il'1G I!'ln t i F- p Address: -600 Sc Suite #: ,qa 1 i f - 1,--- jSpecial Contact Person: SpecialInstructions: Phone No.: Approved per applicable codes. Corrections required prior to approval. COMMENTS: Sprinklers: L 7 ---* 0-‹ /4/Yk,. T/)4 ( — Hrs.: L)L 30L) Sy,f kl, $t — Ok tioZ-1 +,104 Gh� he;� o� y Hood & Duct: `11 Fl k <- 1, h' < - 01.c Monitor: C+ , L Pre -Fire: ' Permits: Occupancy Type: 4 �-- Needs Shift Inspection: 7 Sprinklers: L Date: s -g -/ -- Hrs.: Fire Alarm: y Hood & Duct: `11 Monitor: C+ , L Pre -Fire: ' Permits: Occupancy Type: 4 �-- Inspector: AM r I , Date: s -g -/ -- Hrs.: / $100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. Billing Address Attn: Company Name: Address: City: State: Zip: Word/Inspection Record Form.Doc 3/14/14 T.F.D. Form F.P. 113 i INSPECTION NUMBER INSPECTION RECORD Retain a copy with permit PERMIT NUMBERS CITY OF TUKWILA FIRE DEPARTMENT 206-575-4407 Project:, j 71'(fr- Type Insg-t Sprinklers: Lit Address: Suite #: 2��J Al Contactt#:SG Special Instructions: Phone No.: aApproved per applicable codes. Corrections required prior to approval. COMMENTS: eTz- ce\,Ny2-- Needs Shift Inspection: Date: 5 /0 Sprinklers: Lit Fire Alarm: VCS Hood & Duct: 6 5 Monitor: (q (,p 4 ,0"-) Pre -Fire: Permits: Occupancy Type: 4 — "2 - Inspector: pypt c4-- Date: 5 /0 Hrs.: $100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. Billing Address Attn: Company Name: Address: City: State: Zip: Word/Inspection Record Form.Doc 3/14/14 T.F.D. Form F.P. 113 • Lighting Summary LGT-SUM 2015 Washington State Energy Code Compliance Forms for Commercial Buildings including R2, R3, R4 over 3 stories and all R1 Revised August 2016 Project Info Compliance forms do not require a password to use. Instructional and Project Title: Ruby Thai Kitchen at Westfield Southcenter Date 11/28/2016 Applicant Information. Provide contact information for individual itho can respond to inquiries about compliance form information provided. For Building Department Use r -- Company Name: HIATT ARCHITECTURE Company Address: 4410 W. MELROSE AVE, TAMPA, FL, 33629 r - 7 calculating cells Applicant Name: MOSAD ELEWA—' f -� are wite protected. _, L - Applicant Phone: 813-245-6554 Applicant Email: INFO@MCDART.NET Project Description • New Building • Addition 74 Alteration: i Plans Included Include PROJ-SUM form (included in envelope fomes vorkbook) with lighting complliance forms. Building Additions Compliance Method Interior lighting Exterior lighting a Lighting systems in addition area comply with all applicable provisions as a stand alone new construction project 7. ■ Refer to Section C502.2.6 for additional requirements. Lighting systems in addition are combined with existing building righting systems to demonstrate compliance ■ ■ Ackition is combined with existing: Forinterior lighting projects, include new + existing interior lighting fixture iiettage in Proposed Lighting Wattage table in LTG -INT -BLD or LTG -INT -SPACE form. Forexterior lighting projects, include new + existing exterior lighting fixture rtettage in Proposed Tradable and Proposed Non -Tradable Lighting Wattage tables in LTG -EXT form. Interior and Exterior Lighting Alterations Lighting Power Interior lighting Parking garage Exterior lighting 50% or more of existing are replaced 74 ■ ■ Select all Lighting Potier and Lighting Control elements that apply to the scope Less than 50% of existing are replaced ■ • ■ of the retrofit project. If project includes a combination of spaces Mere less than 50% of the existing fixtures are replaced T.-.- Lamp and/or ballast replacement only —existing total wattage not increased _ _ _ — ■ ■ ■ in some spaces, and 50% or more of the fixtures are replaced in others, then 50% or more replaced - Total lighting potter of new + existing -to -remain fixtures shall comply with provide separate lighting potter total LPA per Sections C405.4.2 and C405.5.2. Include new + existing -to -remain fixtures in compliance forms for the hio retrofit Proposed Lighting Wattage table in LTG -INT -BLD, LTG -INT -SPACE or LTG -EXT form. conditions. Spaces undergoing the same Less than 50% replaced - Total lighting potter of new + existing -to -remain fixtures shall not exceed type of retrofit may be combined into one the total lighting poster prior to alteration. Include new + existing -to -remain fixtures in the Proposed lighting potter compliance form. Lighting Wattage table in LTG -INT -BLD, LTG -INT -SPACE or LTG -EXT form. 50% threshold applies to numberof luminaires for interior spaces and parking garages, and total Refer to Section C503.6 for additional requirements. installed itettage for exterior luminaires. Lighting Controls Interior lighting Parking garage Exterior lighting Il al �.tra 1,.. rel I.. r. e- • em / .e _6.I..1,70'1! - New wiring installed to serve added fixtures fixtures relocated to 7� III■ i CODE COMPLIANCE 11, IVP:101/r-,iil i; DEC 1 6 2016 New or moved lighting panel ■ • ■ Interior space is reconfigured - luminaires unchanged or relocated • i. ■ New wiring or circuit - For interior lighting, provide required manual controls per C405.2.3, City of Tukwila occupancy sensor controls per C405.2.1, daylight responsive controls per C405.2.4 and application specific lighting controls per C405.2.5. For exterior lighting, provide required controls per C405.2.7. New or moved panel - Provide all applicable lighting controls as noted for New Wiring and automatic time switch controls per C405.2.2. systems an ex ng ... uses and configuration are not Reconfigured interior space - Provide all required lighting controls that apply to a new interior changed space. Application specific lighting control provisions per C405.2.5 do not apply to reconfigured Change of Space Use areas under -going a change in space use are upgraded to • Existing interior lighting systems in types per Tables C405.4.2(1) or C405.4.2(2). comply with LPAs for the new space Identify interior spaces requiring LPD upgrade to the current Code in Proposeciplitag9d�(�t ge,}�, table in LTG -INT -BLD or LTG -INT -SPACE form. ��''ii LL,,rr �� 11 �S(( if' (8Ti V nC err trttnsit bU0 0335 DEC 0 8 2016 A PERROT CENTER Lighting Summary, cont. LGT-SUM 2015 Washington State Energy Code Compliance Forms for Commercial Buildings including R2, R3, R4 over 3 stories and all R1 Revised August 2016 Project Title: Ruby Thai Kitchen atWestfield Southcenter (Date 11/28/2016 Interior Lighting System Description NEWTENANT IMPROVEMENTS TO EXISTING RESTAURANT IN MALL FOOD COURT NEW LIGHTS TO BE INSTALLED TO ILLUMINATE PROPOSED RESTAURANT PREP AREA AND SALES AREA Interior Lighting Power Allowance Method • Building Area Method :, Space -by -space Method Select method used in project Interior Lighting Controls , -, All 0405.2.1- 0405.2.8 Controls • C4052 Exception 5 Luminaire Leve! ,. Lighting Control (LLLC) • Additional Efficiency Package Option C406.4 Enhanced digital lighting controls To comply with C406.4, no less than 90% of the total installed interior lighting pouter shall comply with required controls per C406.4. Dwelling Unit Interior Lighting Permanently installed interior lighting fixtures in dt+elling units comply with: • 0 C405.2 ttvu C405.5 Commercial Lighting Controls and LPA 0 C406.3 High Efficacy Lighting 0 • Exterior Lighting System Description N/A Interior Lighting - Space -By -Space Method LTG -INT -SPACE 2015 Washington State Energy Code Compliance Fonns for Commercial Buildings induding R2, R3, R4 over 3 stories and all R1 Revised August 2016 Project Title: Ruby Thai Kitchen at Westfield Southcenter Date 11/28/2016 Calculation Area NOTE 9 0 0 Addition - 0 Addition stand alone + existing 0 Spaces where < 50% of • Spaces where 2 50% of 0 luminaires are replaced luminaires are replaced For Building Department Use LPA Calculation Type • Standard 0 Additional Efficiency Package Option 0 C406.3 Reduced Interior Lighting To comply Kith C406.3, the Proposed LPD shall be 25% loner than the Target LPA. Refer to C406.3 for additional requirements. Maximum Allowed Lighting WattageNOTE 1 Location (plan #, room #) Space Type Ceiling Hei htNOTE 2 g Gross Interior Area in fE Allowed Wattsper ftp Watts Allowed (watts/ttz x area) SALES AREA Sales area 8' 599 1.270 761 Lobby Art/Exhibit Display Allowance from LTG-INT-DISPLAYTE Total Area Retail Display 599 LTG-INT-DISP Allowed Watt- Allowance from 761 Proposed Lighting Wattage': Location (plan #, room #) SALES AREA SALES AREA Fixture DescriptionNOTE 4, 5, 6 RECESSED DOWN LIGHT RECESSED DOWN LIGHT Number of Fixtures 29 31 Watts/ Fixture NOTE 7 11 14 Proposed Retail Display Lighting from LTG-INT-DISPLA Total Proposed Watts may not exceed Total Allowed Watts for Interior Lighting Total Proposed Watts Watts Proposed 313 434 Y 747 Interior Lighting Power Allowance COMPLIES Note 1 - List all unique space types per Table C405.4.2(2) that occur in the project scope. Select space type category per from drop down menu. Note 2 - Indicate ceiling height for atriums and spaces utilizing the ceiling height adjustment per Table C405.4.2(2), Footnotes d thru f. Note 3 - List all proposed lighting fixtures including exempt lighting equipment and existing -to -remain fixtures. Note 4 - For proposed Fbcture Description, indicate fixture type, lamp type (e.g. T-8), number of lamps in the fixture, and ballast type (if included). For track lighting, list the length of the track (in feet) in addition to the fixture, lamp, and ballast information. Note 5 - For lighting equipment eligible for exemption per C405.4.1, note exception number and leave Watts/Fixture blank. Note 6 - Existing -to -remain fixtures shall be included in the Proposed Lighting Wattage table in the same manner as new factures. Identify as existing in fixture description. Note 7 - For proposed Watts/Fi xture enter the luminaire aettage for installed lamp and ballast using manufacturer or other approved source. For luminaires Kith screw-in lamps, enter the manufacturer's listed maximum input tettage of the fixture (not the lamp wattage). For low voltage lighting, enter the wettage of the transformer. For line voltage track/busvey systems, enter the larger of the attached luminaire wattage or 50 vetts/linea/ foot, or enter the wattage limit of permanent current limiting device. Note 8 - Lobby Art/Exhibit Display Allovence is independent of the Maximum Allowed Lighting Wattage. Note 9 - Calculation Area Details: a. Lighting fixtures in a building addition may comply as a stand alone project, or they may be combined Kith the overall existing building lighting systems to demonstrate compliance. Refer to C502.1. Lighting, Motor, and Electrical Permit Checklist, Pg. 1 LTG-CHK 2015 Washington State Energy Code Compliance Forms for Commercial Buildings including R2, R3, R4 over 3 stories and all R1 Revised August 2016 Protect Title: Ruby Thai Kitchen at Westfield Southcenter Date 11/28/2016 The following information is necessary to check a permit application for compliance with the lighting, motor, and electrical requirements in the Washington State Energy Code, Commercial Provisions. Applicability (yes,no,na) Code Section Component Compliance information required in permit documents Location in Documents Building Department Notes LIGHTING CONTROLS Yes C405.2 Lighting controls, general For all lighting fixtures, indicate lighting control method on plans for spaces and lighting zone(s) served, or exception taken E1.0 NA C405.2 Luminaire level lighting controls (LLLC) Indicate on plans all fixtures provided with LLLC in lieu of C405.2 lighting controls; provide description of control capabilities and performance parameters NA C405.1 Lighting in dwelling units For permanently installed lighting fixtures in dwelling units, indicate lighting control method on plans for spaces and lighting zone(s) served, or demonstrate compliance with high efficacy exception Yes C405.2.3 C405.2.1.1 C405.2.2.2 C405.2.4 C405.2.5 Manual controls Indicate on plans the method of manual lighting control (whethe combined with occupancy sensor, automatic light reduction, daylight responsive or specific application controls), location of manual control device and area or specifice application it serves E7.0 NA C405.2.2.1 C405.2.2.2 C405.2.3 Manual interior lighting controls Indicate on plans which method of manual 50% lighting load reduction is provided, or whether lighting load is reduced via occupancy sensors or daylight responsive controls Yes C405.2.2 Method of automatic shut-off control Indicate on plans the method of automatic shut-off control during unoccupied periods (occupancy sensor or time switch) for all lighting zones; E-2 Indicate locations where automatic shutoff is provided by other methods (occupancy sensor or digital timer switch) or which time switch control exception applies NA C405.2.1 C405.2.1.1 Occupancy sensor controls Indicate on plans the spaces served by occupancy sensors; Indicate whether occupancy sensor controls are configured to be manual-on, automatic 50%-on, or serve a space eligible for automatic 100%-on per exception NA C405.2.1.2 Occupancy sensor controls - warehouses Indicate aisleways and open areas in warehouse spaces provided with occupancy sensor controls that reduce lighting power by 50% Yes C405.2.6 Digital timer switch Indicate required digital timer switch control function when control is used E2.0 NA C405.2.2.1 Automatic time switch controls Indicate locations of override switches on plans and the lighting zone(s) served, include area sq. ft. NAFor C405.2.4.2 C405.2.4.3 Daylight zones - Sidelight and toplight Indicate primary and secondary sidelight daylight zone areas on plans, include sq. ft; Indicate toplight daylight zone areas on plans, include sq. ft; small vertical fenestration assemblies (rough opening less than 10 percent of primary daylight zone) where daylight responsive controls are not required, provide fenestration area to daylight zone calculation(s) NA C405.2.4 Daylight responsive controls Indicate on plans lighting zone(s) served by daylight responsive controls; Identify sidelight and toplight daylight zones that are not provided with daylight sensing controls and the exception(s) that apply; _ Indicate on plans the lighting load reduction method - continuous dimming, or stepped dimming that provides at least two even steps between 0%-100% of rated power, Indicate that daylight sensing controls are configured to completely shut off all controlled lights in the lighting zone NA C405.2.5 Additional controls - Specific application lighting controls Identify spaces and lighting fixtures on plans that require specific application lighting controls per this section Yesarea C405.2.5 - Items 182 Display and accent lighting Indicate on plans that display and accent lighting, and display case lighting are controlled independently from both general lighting and other lighting applications within the same space; Indicate manual and automatic lighting control method E1.0 E1.0 Lighting, Motor, and Electrical Permit Checklist, Pg. 2 LTG-CHK 2015 Washington State Energy Code Compliance Fonns for Commercial Buildings including R2, R3, R4 over 3 stories and alt R1 Revised August 2016 Project Title: Ruby Thai Kitchen at Westfield Southcenter Date 11/28/2016 The following information is necessary to check a permit application for compliance with the lighting, motor, and electrical requirements in the Washington State Energy Code, Commercial Provisions. Applicability (yes,no,na) Code Section Component Compliance information required in permit documents Location in Documents Building Department Notes NA C405.2.5 - Item 3 Hotel/motel guest rooms Indicate method of automatic control - vacancy or captive key control of all installed luminaires and switched receptacles in guest room NAcontrol C405.2.5 - Item 4 Supplemental task Indicate method and location of automatic shut-off vacancy for supplemental task lighting, including under-shelf or lighting under-cabinet lighting NAindependently C405.2.5 - Item 5 Lighting for non- visual applications Indicate on plans eligible non-visual lighting applications, include sq. ft. area of each lighting control zone; Indicate on plans that non-visual lighting are controlled from both general area lighting and other lighting applications within the same space_- _ _ _` ` ___ Indicate method of manual lighting control and applicable automatic lighting control __ _ NA - Item 6 Lighting equipment for for sale or demonstration Indicate on plans that lighting equipment for sale or demonstration are controlled independently from both general area lighting and other lighting applications within the same space; Indicate method of manual lighting control and applicable automatic lighting control Yes C405.2.5 - Item 7 Means of egress lighting Identify on plans egress fixtures that function as both normal and emergency means of egress illumination; E7.0 Provide calculation of lighting power density of total egress lighting; ____ -- If total egress lighting power density is greater than 0.02 W/sq. ft., indicate on plans egress fixtures requiring automatic shut-off during unoccupied periods; E7.0 E1.0 Indicate method of automatic shut-off control E1.0 NA C405.2.7 Exterior lighting controls Indicate on exterior lighting plans and fixture schedules the automatic lighting control method, control sequence, and locations served; For building facade and landscape lighting, indicate automatic controls shut off lighting as a function of dawn/dusk and fixed opening/dosing time; For all other exierior lighting, indicate automatic controls shut of( lighting as a function of available daylight; indude control sequence that also reduces lighting power by at least 30% between 12am-6am, or from 1 hour after closing to 1 hour before opening, or based upon motion sensor NA 0405.5.1 Exterior building For building grounds fixtures greater than 100 watts, indicate on grounds lighting plans whether fixtures have efficacy greater than 80 lumens or, controls are controlled by motion sensor, or are exempt lighting per C405.5.2 NA C405.2.5 Area controls - Master control switches and circuitbe power limit Indicate location(s) of master control switch(es) intended to control multiple independent switches; circuit breaker may not used as a master control switch; Verify that no 20 amp circuit controlled by a single switch or automatic control is loaded beyond 80% NA C406.4 Enhanced digital lighting controls 9 9 To comply with additional efficiency package option, indicate on plans all interior lighting fixtures that are individually addressed and provided with continuous dimming, or exception taken; Include calculation of percent total installed interior lighting power that is configured with required enhanced lighting control functions (min 90% to comply with additional efficiency package option) NA C405.13 C408.3 Lighting system functional testing If claiming lighting system commissioning exemption provide supporting calculation; Identify applicable commissioning documentation requirements per Section C408 or eligibility for exception; Provide written procedures for functional testing of all automatic controls and describe the expected system response Lighting, Motor, and Electrical Permit Checklist, Pg. 3 LTG-CHK 2015 Washington State Energy Code Compliance Forms for Commercial Buildings including R2, R3, R4 over 3 stories and all R1 Revised August 2016 Project Title: Ruby Thai Kitchen at Westfield Southcenter Date 11/28/2016 The following information is necessary to check a permit application for compliance with the lighting, motor, and electrical requirements in the Washington State Energy Code, Commercial Provisions. Applicability (yes,no,na) Code Section Component Compliance information required in permit documents Location in Documents Building Department Notes INTERIOR LIGHTING POWER & EFFICACY Yes C405.4.1 C405.4.1 C405.4.2 Total connected interior li htin g g power Include all luminaires in lighting fixture schedule; indicate fixture types, lamps, ballasts, and manufacturer's rated watts per fixture; Identify spaces eligible for lighting power exemption on plans and in compliance forms; indicate the exception applied; Identify lighting equipment eligible for lighting power exemption in fixture schedule and in compliance forms; indicate the exception applied; E1.0 E1.0 ------------------------- E1.0 _--- Indicate that exempt lighting equipment is in addition to general area lighting and is controlled independently E7.0 Yes C405.3 Exit signs Indicate location of exit signs on plans and rated watts per ) fixture in lighting fixture schedule (maximum 5 watts per fixture E1.0 NA C405.1 Lighting in dwelling units - lamp efficacy If high efficacy exception is applied to permanently installed lighting fixtures in dwelling units, indicate in lighting fixture schedule if lamps in fixtures are high efficacy per R404.1. Calculate percentage of fixtures with high efficacy lamps in project (min 75% to comply with exception). NA C406.3 Reduced lighting power density - dwelling unit lamp efficacy For project with dwelling units, to comply with additional efficiency package option indicate in lighting fixture schedule if lamps in fixtures have efficacy rating of 60 lumens per watt or more. Calculate percentage of fixtures with lamps that have this efficacy rating (min 95% to comply with option). Lighting Power Calculation - Indicate compliance path taken NA C405.4.2.1 Building Area Method Complete required compliance forms — proposed wattage per building area does not exceed maximum allowed wattage per building area. Identify locations of building areas on plans Yes C405.4.2.2 Space-By-Space Method Complete required compliance forms— total proposed wattage does not exceed maximum allowed wattage. Identify locations of space types on plans, including retail display areas, lobby art & exhibit display areas, and ceiling heights as applicable NA C406.3 Reduced lighting power density To comply with additional efficiency package option, demonstrate in compliance forms that total connected interior lighting wattage is 75% Tess than the total maximum allowed lighting wattage via Building Area Method or Space-By-Space Method EXTERIOR LIGHTING POWER & EFFICACY NA C405.5.2 Total connected exterior lighting power Include all luminaires in lighting fixture schedule; indicate fixture types, lamps, ballasts, and manufacturer's rated watts per fixture; Identify exterior applications eligible for lighting power exemption on plans and in compliance forms; indicate exception applied; r _ Indicate that exempt exterior lighting is controlled independently from non-exempt exterior lighting; include exception claimed for each fixture or group of fixtures under exception category NA Table C405.5.2(1) Exterior lighting zone Indicate building exterior lighting zone as defined by the AHJ NA C405.5.1 Exterior building grounds lighting For building grounds fixtures rated at greater than 100 watts that are complying based on efficacy, indicate rated lamp efficacy (in lumens per watt) in fixture schedule NA C405.5.2 Exterior lighting power calculations Complete required compliance form — proposed wattage for exterior lighting plus base site allowed does not exceed maximum allowed Lighting, Motor, and Electrical Permit Checklist, Pg. 4 LTG -CHK 2015 Washington State Energy Code Compliance Forms for Commercial Buildings including R2, R3, R4 over 3 stories and all R1 Revised August 2016 Project Title: Ruby Thai Kitchen at Westfield Southcenter Date 11/28/2016 The following information is necessary to check a permit application for compliance with the lighting, motor, and electrical requirements in the Washington State Energy Code, Commercial Provisions. Applicability (yes,no,na) Code Section Component Compliance information required in permit documents Location in Documents Building Department Notes MOTORS & TRANSFORMERS NA C405.6 Electrical tranformers Include electrical transformer schedule on electrical plans; indicate transformer size, efficiency, or exception taken NA C405.7 Dwelling unit electrical energy consumption Indicate on electrical plans that each dwelling unit in Group R-2 has a separate electrical energy meter NA C405.8 Electric motor efficiency Include all motors, including fractional hp motors, in electric motor schedule on electrical plans; indicate hp, rpm, rated efficiency, or exception applied C405.9.1NA Elevator cabsIndicate For luminaires in each elevator cab, provide calculated average efficacy of combined fixtures that indicates efficacy is not less than 35 lumens per watt rated watts per cfm for elevator cab ventilation fans do not exceed 0.33 watts per cfm; Indicate automatic controls that de -energize lighting and ventilation fans when elevator is stopped and unoocupied for a period of 15 minutes or more NA C405.9.2 Escalators and moving walks Indicate escalators comply with ASME A17.1/CSA B44; automatic controls are configured to reduce operational speed to the minimum permitted when not in use C405.9.3NA Regenerative drive Indicate all one-way down or reversible escalators are provided with a variable frequency regenerative drive NA C405.10 Controlled receptacles Identify all controlled and uncontrolled receptables on electrical plans in each space in which they are required; include receptacle configuration such as spacing between controlled and uncontrolled, duplex devices, etc; Indicate on plans whether the method of automatic control for each controlled receptable zone is by occupant sensor or programmable time -of -day control If "no" is selected for any question, provide explanation: End of Lighting, Motor & Transformer Permit Documents Checklist PERMIT COORD COPY PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: D16-0335 DATE: 12/08/16 PROJECT NAME: RUBY THAI KITCHEN SITE ADDRESS: 2600 SOUTHCENTER MALL - FC -15 X Original Plan Submittal Revision # before Permit Issued Response to Correction Letter # Revision # after Permit Issued DEPARTMENTS: A'AtAiu 0-ts-Ve Building Division 3)5 NO- 1 t --(O Public Works AAA AtAIc, Fire Prevention Structural u-‘4—ick 111 LAR, A)/4 Planning Division Permit Coordinator PRELIMINARY REVIEW: Not Applicable (no approval/review required) REVIEWER'S INITIALS: DATE: 12/13/16 Structural Review Required DATE: APPROVALS OR CORRECTIONS: Approved Corrections Required n (corrections entered in Reviews) Notation: Approved with Conditions Denied (ie: Zoning Issues) ludve/ Z\-e.Gd— DUE DATE: 01/10/17 REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: 12/1812013 LARRY MORRISON CONSTRCTToN INC iWashington State Department of , Labor & industries Home Espafiol Contact Safety & Health Claims & Insurance Search L&I Page 1 of 2 A -Z Index Help My UT Workplace Rights Trades & Licensing LARRY MORRISON CONSTRCTION INC Owner or tradesperson Principals MORRISON, LARRY ALBERT, PRESIDENT Doing business as LARRY MORRISON CONSTRCTION INC WA UBI No. 602 189 195 22041/2 186TH AVE E SUMNER, WA 98390 253-862-7373 PIERCE County Business type Corporation License Verify the contractor's active registration / license / certification (depending on trade) and any past violations. Construction Contractor Active. Meets current requirements. License specialties GENERAL License no. LARRYMC980DN Effective — expiration 03/15/2002— 05/13/2018 Bond Hudson Insurance Company Bond account no. 10050735 Received by L&I 12/23/2016 GREAT AM INS CO OF NY Bond account no. 7902865410 Received by L&I 01/27/2003 Insurance ................. Ohio Security Ins Co Policy no. BKS55931590 $12,000.00 Effective date 03/10/2017 Expiration date Until Canceled $12,000.00 Effective date 03/11/2003 Cancelation date 03/10/2017 $1,000,000.00 Received by L&I Effective date 02/12/2016 03/15/2016 Expiration date 03/15/2017 Help us improve https://secure.lni.wa.gov/verify/Detail.aspx?UBI=602189195&LIC=LARRYMC980DN&SAW= 2/13/2017 LARRY MORRISON CONSTRCTION INC Insurance history Savings ......................... No savings accounts during the previous 6 year period. Lawsuits against the bond or savings No lawsuits against the bond or savings accounts during the previous 6 year period. L&I Tax debts ....................................... No L&I tax debts are recorded for this contractor license during the previous 6 year period, but some debts may be recorded by other agencies. License Violations ........................................................ No license violations during the previous 6 year period. Workers' comp Do you know if the business has employees? If so, verify the business is up-to-date on workers' comp premiums. L&I Account ID 401,646-01 ................................. Doing business as MORRISON CONSTRUCTION Estimated workers reported Quarter 4 of Year 2016 "Less than 1 Workers" L&I account representative TO / GARY HONC (360)902-4823 - Email: HONC235@Ini.wa.gov Account is current. Workplace safety and health Check for any past safety and health violations found on jobsites this business was responsible for. Inspection results date 02/25/2013 Inspection no. 316583269 Location 1015 N Pearl St. Tacoma, WA 98406 No violations Page 2 of 2 © Washington State Dept. of Labor & Industries. Use of this site is subject to the laws of the state of Washington. Help us improve https://secure.lni.wa.gov/verify/Detail.aspx?UBI=602189195&LIC=LARRYMC980DN&SAW= 2/13/2017 RESPONSIBILITY SCHEDULE DRAWING INDEX FURNISHED INSTALLED REMARKS C1.0 COVER SHEET A1.0 FLOOR AND CLG. PLANS AND NOTES A2.0 EQUIP. PLAN, SCHED., DETAILS, FINISH SCHED. STOREFRONT ELEVATIONS A4.0 DETAILS A4.1 DETAILS E1.0 ELECTRICAL POWER AND LIGHTING PLANS E2.0 ELECTRICAL PANEL SCHEDULES & RISER DIAL. E3.0 ELECTRICAL SPECIFICATIONS P1.0 PLUMBING WASTE AND WATER PLANS P2.0 PLUMBING WASTE & WATER ISOMETRICS, GAS &ISOMETRIC ITEM: z r- W o o a g TENANT TENANTS CONT LANDLORD TENANT TENANTS CONT z NOTE: TENANT/GC TO CONFIRM ALL EXISTING ITEMS IN FIELD, IF NOT EXISTING, TENANT TO PROVIDE AT TENANT'S EXPENSE. m �� AA3.0 ���� CN �;��� GENERAL REQUIREMENTS 1. PERMITS AND FEES 0 0 2. TEMPORARY UTILITIES 4. TEMPORARY ENCLOSURE AS PER LANDLORDS DISCRETION & CRITERIA SPACE WORK 1. DEMOLITION 2. SAW CUT SLAB/CORE DRILL AS REQUIRED TO INSTALL UTILITIES CONCRETE SLAB CORE DRILLING 1. SAND PAD 2. VAPOR BARRIER WESTFI ELD SOUTHCENTER 2600 SOUTHCENTER MALL, SPACE FC-15PLAN TUK ILA, WA 3. REINFORCING FABRIC 4. CONCRETE SLAB 5. POURED CONCRETE AS REQUIRED TO INSTALL UTILITIES CARPENTRY 1. METAL STUDS A. DEMISING WALLS B. INTERIOR PARTITIONS 0 0 0 SEE PLANS C. FURRING D. SALES COUNTER E. SALES LOW WALL F FRAMING FOR MECH. UNITS KEY PLAN SYMBOLS LEGEND: D2. OORS 1. SALES/KITCHEN DOOR(S) & FRAME SEE SCHEDULE SECTION NUMBER 2. SERVICE DOOR 0 SEE SCHEDULE SECTION CUT 0 INDICATION 3. TOILET ROOM DOOR A-0 SHEET NUMBER FINISHES PLAN DETAIL i 0 - DETAIL AREA 1. WALLS A. 5/8" TYPE "X" GYP. BD. AS REQ'D REVISIONS B. 5/8" MOISTURE RESISTANT GYP. BD. AS REQ'D FUTURE RETAIL .Och►anges shall he made to the scope C. FINISHES SEE PLAN AND STANDARD MATERIAL SCHEDULE INDICATION A-0 DETAIL NUMBER D. COUNTER TOP MATERIAL G.C. TO SUPPLY SAMPLES TO OWNER FOR APPROVAL of work without prior approval of SHEET NUMBER Tukwila 2. TAPING AND SPACKLING ( Building Division. NOTE: Revisions will require a new !an submital and may include additional plan review fees. 3. FLOORS ELEVATION ELEVATION NUMBER 0maty INDICATION A. WATER PROOF MEMBRANE A-0 SHEET NUMBER NORDSTROM ] B. QUARRY TILE DOOR IDENTIFICATION MILWORK 0A NOTES WHICH MOULDINGS APPLY To SPECIFIC ITEMS ON C. DINING FLOORING 4. FINISHES JCPenney RUBY THAI KITCHEN A. PAINT 0 0 B. TILE _ SQ. FT. 599 C. TRIM0 0 r 7 Nva 5. BASE `'�_ 11 CONSTRUCTION NOTES 0 DRAWINGS WHERE INDICATED. A. COVED QUARRY TILE ' ' r B. COVED VINYL -��'proilik 6. CEILING j - - - �>� = y * r?_!\� A. GYP.BD. SEE REFLECTED CEILING TOILET ACCESSORIES A B. 2X4 LAY -IN TILE GENERAL NOTES: 3). NOTES WHICH APPLY TO ALL DRAWINGS. ELEVATION �- i . . �.�` -- E( F PEA IT PLUMBING il��° ""�" r ----v _� l' '--.% re: -...C2 l ! �'�©FQ�: 1. WATER PIPING SEE PLUMBING DWG. j - •/' •� -'� a ,;w,, I I 2. UNDERSLAB ROUGH -IN FOR WASTE SEE PLUMBING DWG. L ` ,.�,� ar4echan "' `� - MALL PROVIDED 3. FINAL CONNECTIONS & VENTS SEE PLUMBING DWG. - ,- ;; _ -- _ectn 4. GAS PIPING AND ACCESSORIES SEE PLUMBING DWG. t `1 '�"fes"_="= PUBLIC RESTROOMS ` N mbl 5. FINAL GAS CONNECTIONS TO EQUIP. - SEE PLUMBING DWG. 00'-0" ELEVATION TARGET L.L. LEASE LINE - ABOVE FIN. FCR. ��- SURFACE DESCRIPTION I c t CENTERLINE 6. TOILET RM. FIXTURES/ACCESSORIES = _- - = WITH -IN 309' FROM Gas P►# EQUIPMENT - - _ - _ "_ -- = = = L - _ a r Jam- _ = = TENANT SPACE City of Tukwila BUILDING 1. KITCHEN/SALES SEE EQUIPMENT SCHEDULE FOR MORE INFO. =., - _ - _ „- _ - DIVISION 2. STOREFRONT SIGNS 0 0 COORD. PERMITS & INSTALLATION W/ SIGN VENDOR 3. FIRE EXTINGUISHER LOCATE PER FIRE MARSHALL 4. INTERCOM SYSTEM 0 DIAMETER 5. SEATING 6. MENU BOARD 0 0 COORDINATE WITH VENDOR (VERIFY W/ TENANT) ABBREVIATIONS : CODE INDEX LANDLORD NOTES 7. SALES AREA S/S COUNTERS COORDINATE WITH TENANT. ELECTRICAL A.F.F. ABOVE FINISH FLOOR F.O.S. FACE OF STUD O.C. ON CENTER ACT. ACOUSTICAL FT. FEET OPNG. OPENING ADJ. ADJUSTABLE F.N.D. FEMININE NAPKIN DISPOSAL O.D. OUTSIDE DIAMETER A.C. AIR CONDITION/CONDITIONED/ F.N.V. FEMININE NAPKIN VENDOR PR. PAIR P.T.D. PAPER TOWEL CONDITIONER/CONDITIONING FIN. FINISH DISPENSER ALT. ALTERNATE FIN. OPNG. FINISH OPENING P.T.H. PAPER TOWEL HOLDER ALUM. ALUMINUM F.E. FIRE EXTINGUISHER A.B. ANCHOR BOLT F.E.C.R. FIRE EXTINGUISHER CABINET P.COL. PIPE COLUMN PLAS. PLASTER & AND RECESSED P.LAM. PLASTIC LAMINATE APPROX. APPROXIMATELY F.H. FIRE HYDRANT PLUMB. PLUMBING @ AT F.R.P. FIRE RETARDANT PANEL P.C. PLUMBING CONTRACTOR AWN. AWNING F.R.T. FIRE RETARDANT TREATED PLYWD. PLYWOOD B.C. BASE CABINET FFLOOR P.T. PRESSURE TREATED B.P. BASE PLATE F.D. FLOOR DRAIN Q.T. QUARRY TILE BM. BEAM F.P. FLUSH PANEL BLK. BLOCK FTG. FOOTING R. RADIUS B.S. BOTH SIDES F.M. FRAMED MIRROR RECT. RECTANGULAR B.W.BOTH WAYS GALV. GALVANIZED REINF. REINFORCEMENT REQ'D. REQUIRED BTM. BOTTOM BRK. BRICK GA. GAUGE REV. REVISION G.C. GENERAL CONTRACTOR R.D.OF DRAIN BLDG. BUILDING GL. GLASS CAB. CABINET G.B.GRAB BAR RM. ROOM R.O. ROUGH OPENING CPT. CARPET G.W.B. GYPSUM WALLBOARD C.I. CAST IRON GYP. GYPSUM S.C.O.F. SUP COEFFICIENT C.B. CATCH BASIN HC. HANDICAPPED SCH. SCHEDULE CLG. CEILING HDW. HARDWARE SNT. SEALANT CEM. CEMENT HT. HEIGHT SECT. SECTION CTR. CENTER H. HIGH SIM. SHEET C.T. CERAMIC TILE H.C. HOLLOW CORE SIM. SIMILAR CHBD. CHALKBOARD H.M. HOLLOW METAL S.D. SOAP DISPENSERss�%"��� C.O. CLEAN OUT HORIZ. HORIZONTAL S.H. SOAP HOLDER CLO. CLOSET IN. INCH S.C. SOLID CORE COL. COLUMN INCL. INCLUDE S. SOUTH COM. COMBINATION I.D. INSIDE DIAMETER SPECS. SPECIFICATIONS CONC. CONCRETE INSUL. INSULATION SQ. SQUARE CONST. CONSTRUCTION JT. JOINT SQ.FT. SQUARE FEET C.M.U. CONCRETE MASONRY UNIT JST. JOIST S.S. STAINLESS STEEL CONT. CONTINUOUS LAM. LAMINATED STD. STANDARD CONTR. CONTRACTOR L.L. LANDLORD STL. STEEL C.J. CONTROLJOINT LAV. LAVATORY STR. STRUCTURAL C.TOP COUNTER TOP L. LONG S.M.S. STRUCTURAL METAL DEMO. DEMOLITION MGR. MANAGER STUD DEPART. DEPARTMENT M.H. MANHOLE SUSP. SUSPEND DTL. DETAIL MFR. MANUFACTURER SYS. SYSTEM TKBD. TACKBOARD DIA. DIAMETER MAS. MASONRY T.C. TENANT CO-ORDINATOR DIM. DIMENSION M.O. MASONRY OPENING DR. DOOR MAT'L. MATERIAL T.P.H. TOILET PAPER HOLDER T.& G. TONGUE AND GROOVECITY DN. DOWN MAX. MAXIMUM T.B. TOWEL BAR G MECH. MECHANICAL DWG. EACH DRAWING MT. METAL TYP. TYPICAL, UNLESS OTHERWISE NOTED E. EAST M.F. METAL FRAME U.N.O. UNLESS NOTED OTHERWISE ELEC. ELECTRICAL M.S. METAL STUD MIN. MINIMUM V.T.R. VENT THROUGH ROOF E.C. ELECTRICAL CONTRACTOR VERT. VERTICAL E.W.C. ELECTRIC WATER COOLER M. MIRROR ELEV. ELEVATION MISC. MISCELLANEOUS V.T. VINYL TILE ENCLOSURE M.R. MOISTURE RESISTANT W.R. WASTE RECEPTACLE EQ. EQUAL M.B.H. MOP AND BROOM W.C. WATER CLOSET EQUIP. EQUIPMENT HOLDER W.H. WATER HEATER EXIST. EXISTING MTD. MOUNTED W.P. WATER PROOF E.J. EXPANSION JOINT N. NORTH W. WEST / WIDE EXP. EXPOSED N.I.C. NOT IN CONTRACT W/. WITH EXT. EXTERIOR N.T.S. NOT TO SCALE W/O. WITHOUT NO. NUMBER WD. WOOD BUILDING CODE: INTERNATIONAL BUILDING CODES W/ WASHINGTON AMENDMENTS: 4 tReTTINTERNATIONAL BUILDING CODE , ;1Q 2 INTERNATIONAL RESIDENTIAL CODE W/ WASHINGTON AMENDMENTS lf O .?.�12 INTERNATIONAL MECHANICAL CODE W/ WASHINGTON AMENDMENTS ,214.2 UNIFORM PLUMBING CODE W/ WASHINGTON AMENDMENTS 2014 NATIONAL ELECTRICAL CODE W/ WASHINGTON AMENDMENTS WASHINGTON STATE ENERGY CODE TYPE OF CONSTRUCTION IIB 1 These Intent verified is One required ,:.,•,_�, Working Drawing Review Approved Approved as Noted C:1 Resubmit drawings have been reviewed for general design Y All actual fieldcondiGonsarerequiredtobe by the Tenant's Architect andior ContractorTenant . responsible for complying with all government regulations. (1) copy of this landlord stamped set of drawings is to be k ton job site tall times. 1/21 /20161' E' {; 1. CONDUIT INTO SPACE 2. METER SEE ELECTRICAL DRAWINGS 3. PANELS 0 0 SEE ELECTRICAL DRAWINGS 4. TRANSFORMER AND GEAR 5. LIGHT FIXTURES AND LAMPS SEE ELECTRICAL DRAWINGS 6. TELEPHONE WIRING 0 0 0 MECHANICAL 1. HVAC SYSTEM A. HVAC UNIT 0 OCCUPANCY GROUP TOTAL LEASED AREA: 599 S.F. B. DUCTWORK0 OCCUPANT LOAD: 4 WORKERS AT ALL TIME C. DIFFUSERS REQUIRED EXIT WIDTH: 36" INCHES 2. ROOF PENETRATIONS PROVIDED EXIT WIDTH: 36" INCHES 3. SPRINKLER SYSTEM MODIFY EXISTING Permit Si ned Date ._. _w_t._ M ff..a _ 4. EXHAUST HOODS & FANS GENERAL NOTES 5. EXHAUST HOOD DUCT WORK 6. EXHAUST HOOD ANSUL SYSTEM SEE HOOD DWG. 7. ROOF PROTECTION ACCESSORIES SEE HOOD DWG. 1. THESE DOCUMENTS REPRESENT THE SCOPE OF WORK TO BE TO PERFORMED BY THE GENERAL CONTRACTOR (U.N.O.) 2. CHECK DIMENSIONS AND CONDITIONS IN THE FIELD ALL DIMENSIONS AND CONDITIONS OF THIS JOB SHALL BE FIELD CHECKED BY GENERAL CONTRACTOR WHO WILL BE RESPONSIBLE FOR SAME. ANY DISCREPANCIES SHALL BE REPORTED TO THE ARCHITECT PRIOR TO THE START OF CONSTRUCTION. COSTS DUE TO A FAILURE OF REPORTING THESE DISCREPANCIES WILL BE THE RESPONSIBILITY OF THE GENERAL CONTRACTOR.( 3. ERRORS AND OMISSIONS ANY DISCREPANCIES OR OMISSIONS ON THESE DOCUMENTS MUST BE BROUGHT TO THE ATTENTION OF THE ARCHITECT PRIOR TO THE COMMENCEMENT OF CONSTRUCTION AND BID TO OWNER. FAILURE BY THE CONTRACTOR TO IDENTIFY DISCREPANCIES OR OMISSIONS WILL THEN BECOME THE RESPONSIBILITY OF THE CONTRACTOR. 4. COMPLY WITH DESIGN CRITERIA GENERAL CONTRACTOR TO FOLLOW AND COMPLY WITH LANDLORD'S TENANT DESIGN CRITERIA AND REQUIREMENTS FOR ALL EXHIBITS. (IF APPLICABLE. ) 5. NOTES ALL NOTES ON ANY PORTION OF THESE DOCUMENTS APPLY TO ENTIRE DOCUMENT WHETHER OR NOT THEY ARE REPEATED IN OTHER AREAS.� 6. WORK, MATERIALS AND CONSTRUCTION METHODS ALL WORK, MATERIALS AND CONSTRUCTION METHODS SHALL CONFORM WITH ALL GOVERNING AUTHORITIES HAVING JURISDICTION. 7. APPROVAL BY GOVERNING AUTHORITIES APPROVAL OF THESE DRAWINGS BY GOVERNING AUTHORITIES DOES NOT RELEASE THE CONTRACTOR FROM COMPLYING WITH ALL APPLICABLE CODES AND STANDARDS. INSTALLATION BY GENERAL CONTRACTOR ALL MATERIALS AND EQUIPMENT ITEMS SUPPLIED BY THE OWNER/TENANT ARE TO BE INSTALLED BY GENERAL CONTRACTOR UNLESS INDICATED OTHERWISE. SPECIAL NOTES: 8. EXH. HOOD MUA SUPPLY SYSTEM SEE HOOD DWG. 9. FIRE ALARM AND SMOKE CONTROL SYS. 0INSTALL/ MODIFY EXISTING SYSTEM PER L.L. REQUIREMENTS g� P171 r: vlmr "j ,F)rov1 Is subject to errors and omisv14nn3. ?A"`"Oval of consi lotion documents does not authorize I , .'' e r� violation Cii any adopted code or ordinance. Rec" i1'sf f rove Field `� • ! .'ins IS acknowled nd: �`" Cat ' / " Mb/ PROJECT ■ INFORMATION. • LANDLORD. PROJECT COORDINATOR ARCHITECT Date.'' %� �� %� of Tukwila City BUILDINGDIVISION • MATT KOENIGS / SR. PROJECT MANAGER / WESTFIELD NATIONAL ACCOUNTS 835 MAI2IT STREET, SUITE 517 / SAN FRANCISCO, CA 94103 E / MKOENIGS@WESTFIELD.COM MOSAD ELEWA 3386 CLARINE WAY WEST DUNEDIN, FL 34698 TEL. 813-245-6554 DAVID HIATT, ARCHITECT 4410 W MELROSE AVE. TAMPA, FL 33629 PHONE. (813) 333-2717 FAX. (813) 289-33328. P / 310.210.9965 FAX. 801-218-6554 9. MATERIALS ALL MATERIALS SHALL BE NEW AND FIRST CLASS. ALL WORK AND EQUIPMENT ITEMS SHALL BE WARRANTIED BY THE CONTRACTOR FOR A MINIMUM OF ONE YEAR FROM THE DATE OF FINAL ACCEPTANCE. EXCEPT FOR MANUFACTURE'S WARRANTY WHICH MAY BE LONGER. 10. COMBUSTIBLE MATERIALS NO COMBUSTIBLE MATERIALS ARE PERMITTED ABOVE CEILING.E 11. FIRE EXTINGUISHERS CAPACITY AND RATING AS REQUIRED BY N.F.P.A. PAMPHLET #10 AND LOCAL AUTHORITIES. LOCATE PER LOCAL AUTHORITIES AND N.F.P.A. 10. VERIFY LOCATION WITH FIRE DEPARTMENT 12. MISC. PRIOR TO INSTALLING SHELVING IN REFRIGERATOR, T.G.C. TO WASH DOWN (SPONGE) INTERIOR THREE (3) TIMES WITH A SOLUTION OF 50% VINEGAR AND 50%WATER. SET REFRIGERATOR TO OPERATE AT 34 - 38 F RANGE. 13. PERFORMANCE BOND AND PAYMENT BONDS ARE REQUIRED FOR THIS PROJECT. REFER TO SHEET AS -1. 14. SOME SPECIFIED ITEMS (SUCH AS FLUORESCENT FIXTURES IN SALES COUNTER, WALL STANDARDS, SHELVING BRACKETS, CERAMIC TILE, ETC.) MAY REQUIRE LONG DELIVERY 15. CONTRACTOR AND ALL SUB -CONTRACTORS SHALL VISIT JOB SITE PRIOR TO THE BID. TO REVIEW ACTUAL FIELD CONDITIONS THAT MAY AFFECT THE BID. CONTACT ARCHITECT WITH ANY FIELD CONDITION AFFECTING DRAWINGS BEFORE BID TO OWNER. IF NOT COMMUNICATED WITH THE ARCHITECT, THEN CONTRACTOR & SUB -CONTRACTOR WILL BECOME RESPONSIBLE FOR ALL COSTS INVOLVED. REVIEWED FOR CODE COMPLIANCE APPROVED DEC 6 2016 RECEIVED p�1°�-�+ y p��p �f OF TUKWILA ILA p q DEC O 8 2016 OWNER / TENANT BUILDING DEPT. HEALTH DEPT. INNOVATED RESTAURANT GROUP, INC. ONE HARBOUR PLACE, SUITE 290 777 S. HARBOUR ISLAND BLVD.ENCL. TAMPA, FL, 33602 TEL:813-223-1688 FAX: 866-332-3118 CITY OF TUKWILA BUILDING DIVISION 6300 SOUTHCENTER BLVD #100 TUKWILA, WA 98188 ATTN: PLAN REVIEW TEL.: (206) 4313670 DEPARTMENT OF HEALTH- SEATTLE & KING COUNTY 999 3RD AVE. SUITE 1200 SEATTLE, WA 98104 ATTN: PLAN REVIEW TEL.: (206) 296 4600 ,�J Citycif Tukwila BUILDING DIVISION PERMIT CENTER (0.... 0 335 DATE: 11-4-16 JOB NO: 1670 DRAWN: CHECKED: J=3 AOnU WESTFIELD SOUTHCENTER REVISIONS "Ce -J 4410 W. MELROSE AVENUE TAMPA, FLORIDA 33629 TEL. 813.333.2717 FAX. 813.289.3332 SEAL 4191A�1' ri% Yu 10311HUV G 3 V 31S151t1 COVER SHEET SHEET NUMBER c1uo GC / BARRICADE VENDOR TO COORDINATE INFIELD WITH MALL OPERATIONS FINAL BARRICADE PLACMENT 3'-0" LEASE LINE OR AS MODIFIED TO ENSURE EXISTING MALL SEATING MAINTAINED OR TO ACCOMIVIATE ANY ADJACENT MALL ITEMS. TENANT SIDE FRP OVER DURAROCK BD. WATER PROOF MEMBRANE INSTALLED PER MFG. SPECIFICATIONS. PERIMETER OF TENANT SPACE. TYPE OF WATERPROOFING SUBJECT TO L.L. APPROVAL - iD FLOOR TILE a MALL SIDE WALL FINISHES, SEE ELEVATIONS 4" STAINLESS STEEL BASE EXISTING MALL FLOORING a TO BACK SIDE OF BASE TYPICAL PERIME WATER PROOFI( TH RU -OUT SPA( SCALE: N.T.S. SHOW WATERPROOFING DETAIL ENTIRE FLOOR AREA (LEASED SPACE) TO HAVE WATERPROOF MEMEBRANE INSTALLED WITH WATERPROOF MEMBRANE EXTENDING 6" UP ALL PERIMETER WALLS. , r / /1 r— r'r-rPs11--I,s, T1/1P1 r,r� MirMir Mir Miir Mir '4111111W Mir Mir MY *Ur' - JL.�I__.._ I • GC TO CONFIRM ALL LEASE LINE DIMENSION INFIELD AFTER DEMO AND PRIOR TO FRAMING. REPORT ANY DISCREPANCIES TO LANDLORD. 7.4 CONSTRUCTION NOTES 100 LOW WALL UNDER HOOD SHALL BE CONSTRICTED OF 5/8" TYPE 'X' GYP. BD. OVER 3-5/8" MTL. STUDS. 1024) 105 0107) AS REQUIRED, GENERAL CONTRACTOR TO CONTINUE MALL FINISHES ON FLOOR FROM LEASE LINE TO FACE OF TOE KICK. FRONT LEASE LINE IS AT FRONT COUNTER FACE AVD TO COVER ALL RECESSED AREAS. INSTALL NEW LOW WALL PER SCTION AND DETAILS WALL TILE, SOFFIT TILE AND BASES IN ROOMS WITH GYPSUM WALLBOARD WALLS SHALL BE THIN SET WITH ADHESIVE IN ACCORDANCE WITH THE TILE COUNCIL OF AMERICA, INC. ANSI A-108.5. NOTE: ALL WALL AND SOFFIT TILE SUPPLIED AND INSTALLED BY GENERAL CONTRACTOR. GENERAL CONTRACTOR SHALL INSTALL NEW STAINLESS STEEL PANELS OVER 5/8" GYP. FROM TOP OF QUARRY TILE BASE TO TOP OF LOW WALL, ALONG THE LENGTH OF THE HOOD. GENERAL CONTRACTOR SHALL INSTALL A SCHLUTER-QUADEC CORNER GUARD AT ALL TILE TO TILE CORNERS. QUARRY TILE FLOOR FINISH QT -1 TO BE SUPPLIED AND INSTALLED BY THE GENERAL CONTRACTOR PER THE LATEST ADDITION OF THE TILE COUNCIL OF AMERICA, INC. "HANDBOOK FOR 011(?CERAMIC TILE INSTALLATION" #F113-94 FOR INTERIOR FLOORS. PROVIDE SANDED GROUT WITH ACRYLIC ADDITIVE; INSTALL PER MANUFACTURER'S SPECIFICATIONS O'/ER WATERPROOF MEMBRANE, SEE DETAIL 1/A-1. 111 CUT OUT FOR EQUIPMENT. VERIFY SIZE PRIOR TO CUTTING COUNTER TOP. SEE EQUIPMENT PLAN AND SCHEDULE. EXISTING LANDLORD STRUCTURE COLUMN NOT TO BE CHANGED OR MOVED. 114) GENERAL CONTRACTOR SHALL PROVIDE AND INSTALL 5/8" TYP. "X" GYP. BD. CEILING/SOFFITS AND PAINT PER REFLECTED CLG. PLAN, SECTIONS, AND ELEVATIONS. GENERAL CONTRACTOR SHALL PROVIDE AND INSTALL NEW CASEWORK AND COORDINATE WITH EQUIP. SUPPLIER, SEE SECTIONS ON SHEET #A4.0 INSTALL ALL FINISHES AS SPECIFIED. ALL JOINTS IN AND AROUND CABINETS, SINKS, VENTILATOR, ICE BIN, ETC., TO BE SEALED WITH CLEAR SILICONE SEALANT. PROVIDE BLACK PLASTIC WIRE WAY GROMMETS AT ALL DRILLED OPENINGS. (116) ALL SIGNAGE TO BE APPROVED UNDER SEPARATE SUBMISSION BY SIGN MANUFACTURER. SUBMIT SHOP DWGS. TO L.L. FOR APPROVAL. LIGHTING FIXTURE SCHEDULE 0000 TYPE SYMBOL DESCRIPTION QTY. MANUFAC. CATALOG LAMP MTG. VOLT REMARKS LAMPS/ FIXT. BALLASTS BALLAST/ FIXT. TOTAL WATT C FLEXIBLE LINE VOLTAGE LED LINEAR STRIP 56 FT. INFINA DL -AC -FLEX -30 LED 3000K WARM WHITE COVED 120 PROVIDE ALL REQ'D. HARDWARE 4W/FT. E RECESSED DOWN LIGHT 29 LITHONIA 6G1MW LED 10.8 WATT LED (620 LUMENS) RECESSED 120 10%-100% DIMMING 1 1 10.8 G RECESSED DOWN LIGHT 31 JUNO IC1 LEDG4-3K- 1 14W -WH 14 WATT LED 14 NOTES: OELECTRICAL CONTRACTOR TO INQUIRE ABOUT LOCAL REBATES 0 INSTALLATION OF LIGHT FIXTURES SHALL BE ACCORDING TO MA CODE REQUIREMENTS. ON LIGHT FIXTURES. NUFACTURER'S RECOMMENDATIONS AND ACCORDING TO ALL LAMPS IN FLUORESCENT LIGHT FIXTURES TO BE SYLVANIA UNLESS NOTED OTHERWISE. OPROVIDE LIGHT TUBE COVERS, LENSES, ETC., AS REQUIRED TO PROTECT FOOD SERVICE AREA. LEASE DIMENS ON EXISTING GATE LOCATION TO STAY AS 15, COORDINATE INFIELD WITH MALL FACILITIES. ADJUST DOOR FLOOR PLAN ACCORDINGLY GATE DETAIL rir 49 4330 1049;111 ----- / -`----- LINE OF EXISTING EXH. HOOD ABOVE D-101/2" 11'-51/2" 14'-4 1/2r, COUNTER TO FOLLOW LEASE LINE ARC 22'-41r DEMOLITION NOTES e GENERAL CONTRACTOR SHALL REMOVE ALL EXISTING WALLS. Q GENERAL CONTRACTOR SHALL REMOVE ALL CEILING SOFFIT/ HOOD ENCLOSURE FINISHES AND REPLACE WITH NEW PER ELEVATIONS AND FINISH SCHEDULE. 3D GENERAL CONTRACTOR SHALL REMOVE EXISTING FLOATING LIGHT TROUGH. QEXISTING EXH. HOOD, EXH. FAN, AND MAKE UP AIR FAN TO REMAIN. GENERAL CONTRACTOR SHALL VERIFY CONDITION OF ALL COMPONENTS, SERVICE ALL FANS, AND RESTORE HOOD TO LIKE NEW CONDITION. REDO ANSUL SYSTEM FOR NEW COOKING EQUIPMENT. GENERAL CONTRACTOR SHALL EXISTING LOW WALL AND COUNTER CABINETS, INSTALL NEW PER PLANS AND NEW COUNTER DETAILS. GENERAL CONTRACTOR SHALL REMOVE EXISTING FLOOR FINISHES THROUGHOUT SPACE, ENTIRE FLOOR AREA (LEASED SPACE) TO HAVE WATER 6-1 PROOF MEMBRANE INSTALLED WITH WATERPROOF MEMBRANE EXTENDED 6" UP ALL PERIMETER WALLS. CONTRACTOR TO PROVIDE SPECIFICATION FOR LANDLORD REVIEW/APPROVAL. EXISTING MALL FLOORING TO REMAIN. GENERAL CONTRACTOR TO RESTORE TO LIKE NEW CONDITION AND PATCH AND REPAIR AS NECESSARY ALONG LEASE LINE. G.C. TO EXTEND MALL FLOORING TO TENANT BASE COVE, LEASE LINE, AND/OR IN ALL AREAS TENANT DESIGN RECESSED BEHIND LEASE LINE. a8 GENERAL CONTRACTOR SHALL RELOCATE ALL EXISTING DROP IN SINKS TO NEW LOCATION SHOWN ON EQUIPMENT PLAN. RESTORE ALL SINKS TO LIKE NEW CONDITION. GENERAL CONTRACTOR SHALL PATCH MALL SLAB TO AS -NEW CONDITION AT AREAS WHERE FLOOR SINKS REMOVED. EXISTING FLOOR SINKS TO REMAIN. SEE PLUMBING DRAWING. 10 GENERAL CONTRACTOR SHALL VERIFY THE CONDITION OF THE EXISTING WATER HEATER AND MOP SINK, RESTORE TO LIKE NEW CONDITION, AND INSTALL NEW AS REQUIRED. El EXISTING STRUCTURAL COLUMN TO REMAIN. GENERAL CONTRACTOR SHALL REMOVE EXISTING FINISHES AND INSTALL NEW PER ELEVATIONS. 12 EXISTING ELECTRICAL POWER SUPPLY AND PANELS TO REMAIN. SEE ELECTRICAL DRAWING. LL1 gARRICA�E Mme-.. - - -�,- r r- ! ri /; // �I 1 11 1 ; ----- 1 4 h 1 1 Il 1 L 24'-1" .1 BARRICADE GENERAL CONTRACTOR SHALL PROVIDE AND INSTALL BARRICADE AROUND THE WHOLE SPACE, 3'-0" OFF THE LEASE LINE, ALL DOORS TO SWING IN. BARRICADE TO BE BUILT ACCORDING TO LANDLORD CRITERIA. DEMOLITION PLAN C A I n" SIGN! 116 LINE OF EXISTING EXH. HOOD rR CESSED LED. LIGHT FIXT. S E ELEC. DRAWINGS. JONTINUOUS COVED LED LIGHT 6'-9" A.F.F. OVE LIGHT LEDGE SIGN 71-9" A.F.F. GYP. BD. CLG. 114 P- EXISTI G GYP. BD. SOFFIT AND A.OVE FASCIA REFLECTED CLG. PLAN I SCALE: 1/4" = 1'-0" NOTE. ALL LIGHT FIXTURES ABOVE THE SERVICE, PREPARATION, UTENSIL WASHING AND FOOD STORAGE AREAS (INLCUDING THOSE LIGHTS WITHIN STEAM TABLES, REFRIGERATION UNITS HOODS AND COOKING EQUIPMENT) SHALL BE SHIELDED OR EQUIPPED WITH SHATTER -PROOF BULBS. DATE: 11-4-16 JOB NO: 1670 DRAWN: CHECKED: )=3 Mint' WESTFIELD SOUTHCENTER REVISIONS REVISED PER LANDLORD 11-14-2016 4410 W. MELROSE AVENUE TAMPA, FLORIDA 33629 TEL. 813.333.2717 FAX. 813.289.3332 LANDLORD NOTES: ply- 0335 REVIEWED FOR 'CODE COMPLIANCE APPROVED DEC 1 2016 City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA DEC 0 8 2016 PERMIT CENTER SEAL REGISTERED ARCHITECT DAVID W. HIATT STATE OF WASHINGTON FLOOR PLAN, CEILING PLAN & NOTES SHEET NUMBER A1.0 EQUIPMENT SCHEDULE (-- EXISTING TO REMAIN MARK ITEM/RESPONSIBILITY CWTY. DIMS SPECIFICATIONS: REMARKS: (.90 Z74- cA oU' - W m cc 1 COUNTER (CSCI) 1 VARIES SEE PLAN CUSTOM FABRICATED, SEE SECTIONS. PROVIDE AND INSTALL MARINE GRADE PLYWOOD AT ALL WET AREAS INCLUDING BEVERAGE AND STEAM TABLE AREAS. 2 CASH REGISTER (OSCI) 2 16.6" W 16.8" D 11.7" H SHARP MODEL #ER -A530 WITH SPILL -PROOF KEYBOARD, 120 V 3 10 WELLS STEAM TABLE (OSCI) 1 VARIES SEE PLAN STAINLESS STEEL STUDIO. CUSTOM FABRICATED, SEE SECTIONS. 208V, 3PH,12 KW, 50 AMP & 208V, 1PH, 30 KW, 20 AMP 3.1 2 WELLS DROP-IN REFRIGERATED COLD PAN (OSCI) 1 29-3/4" W 24" D 19-5/8" 11 ATLAS METAL MODEL #WCM-2 3.9 AMPS. - 120V - 1/5HP CUT-OUT REQUIRED: 22-1/4" D x 28" W NEMA 5-15P 3/4" I.D. 4 SOUP/NOODLE WARMER (OSCI) 1 VARIES SEE PLAN STAINLESS STEEL STUDIO. CUSTOM FABRICATED. 208V, 3PH, 9 KW, 25 AMP 5 SNEEZE GUARD (OSCI) 2 VARIES SEE PLAN CUSTOM FABRICATED WITH LIGHT FIXTURE 120 V FOR LIGHT FIXTURE 6 UNDERCOUNTER BAG -IN BOX (OSCI) 1 COKE CO. 7 SODA DISPENSER/ ICE BIN (OSCI) 1 COKE CO. FIELD VERIFY EQUIP. BEFORE MAKING ANY CUTS IN THE COUNTER TOP. FITS CUT OUT MEASURING 23-1/4"x23-1/4" CONTACT SANDY MANUEL(813)973-3465 TO COORD. DELIV. 9 REAR COUNTER (CSCI) 3 VARIES SEE PLAN CUSTOM FABRICATED STAINLESS STEEL. 10 MENU BOARD (SSCI) 8 VARIES SEE PLAN CUSTOM FABRICATED LCD PANELS 11 CONDIMENT HOLDER (CSCI) 5 SEE PLAN COORDINATE WITH OWNER RECESSED IN COUNTER; FIELD VERIFY DIMENSIONS BEFORE MAKING ANY CUTS IN THE COUNTER TOP. 13 GRIDDLE (OSCI) 1 18" W 28" D 39" H RANKIN-DELUX MODEL #GT -18 -F -C 36,000 BTU/HR 3/4" GAS INLET IS LOCATED AT REAR. PROVIDE DORMONT QUICK DISCONNECT SYSTEM. 15 2 CHAMBER WOK (OSCI) 2 56" W 62" H 42" D ALLSTRONG MODEL #ARE -2 240,000 BTU 1-1/4" MAINFOLD I.P.S. PROVIDE DORMONT QUICK DISCONNECT SYSTEM 20 COMBI OVEN (OSCI) 1 33-1/4" W 30-3/8" D 30-3/4" H RATIONAL MODEL #A619106.12.202 30.8 AMPS 208/3P 11.1 KW. 1/2" COLD WATER AND 2" DRAIN LINE STEAM TEMPERATURE RESISTANT DRAIN. 20.1 OVEN STAND (OSCI) 1 33" W 30" D 36" H CUSTOM FABRICATED STAINLESS STEEL 24 GAS FRYER (OSCI) 2 15.62" W 34.29" D 44.22" H FRYMASTER MODEL #MJ35 110,000 BTU/HR UNIT TO BE VENTED UNDER CANOPY W/MECH. EXHAUST SYS. 3/4" I.P.S. MANIFOLD AND GAS CONNECTION. 26 EXH. HOOD (OSCI) 1 24"H EXISTING TO REMAIN. W/LIGHT FIXTURES. LENGTH & WIDTH VARY, SEE PLAN. ANSUL SYSTEM TANKS AND CONTROL PANEL 1 "ANSUL" PRE -ENG. LIQUID CHEMICAL FIRE SUPPRESSION SYS. W/FIXED NOZZELS. SYS. TO BE UL CLASSIFIED AND INSTALLED PER NFPA #96 REQ. SYSTEM SHALL BE CAPABLE OF AUTOMATIC AND MECH. OPERATION W/AUTO SOLINOID GAS VALVE SHUT DOWN. ASSEMBLY, TESTING AND CERTIFICATION BY GEN. CONTR. INSTALL SYSTEM AS CLOSE TO CEILING AS POSSIBLE. MIN HGT. TO BOTT. OF UNIT TO BE 6'-6' AFF. NOTE: NOZZELS AND PIPING IN PUBLIC VIEW SHALL BE CHROME FINISHED. ELEC: FOR EMERGENCY SHUT OFF, CONNECT CONTROL PANEL TO SOLINOID FOR SHUT DOWN OF GAS SUPPLY UPON ACTIVATION. PLUMB:CONNECT ANSUL TANKS TO HOOD W/ RED PAINTED PIPE. INSTALL GAS SOLINOID VALVE SIZED PER PIPE SIZE. 29 ICE MAKER (OSCI) 1 CUBER: 30" W 24.50" D 21.50" H MANITOWOC MODEL #QY-0605W 208-230/60/1, AIR COOLED, 9.2 AMPS, 1 HP 9,000 BTU/HR (AVERAGE) 1 BIN: 30" W 34" D 44" H MANITOWOC MODEL #S-570 ON 6" LEGS ALLOW 6" AIR CLEARANCE @ BACK OF UNIT. ELEC.: SIMPLEX @ 80" A.F.F. (3 WIRE WITH NEUTRAL FOR 115V) PROVIDE 6' CORD AND PLUG TO UNIT. PROVIDE 3/4" INDIRECT WASTE DRAINS FROM BIN & CUBER. 3/8" O.D. CONDENSATE AND 1/2" INDERECT WASTE FROM CONDENSER TO FLOOR DRAIN. MAINFOLD AS REQUIRED. 32 DROP-IN 3 -COMPARTMENT SINK (OSCI) 1 56" W 25" D 12" H EXISTING RELOCATED ADVANCE TABCO MODEL# DI -3-1612 20"X16"X12" BOWLS 1/2" HOT & COLD WATER, 2" I.D. WASTE 33 DROP-IN 1 -COMPARTMENT SINK (OSCI) 1 23" W 21" D 12" H EXISTING RELOCATED ADVANCE TABCO MODEL# DI -1-2012 20"X16"X12" BOWL 1/2" HOT & COLD WATER, 1-1/2" I.D. WASTE TTIT LLLL ELECTRI ANEL HAND SINK GRIDDL COUNTER MOP SIN BELOW HOOD 2 HOLE WOK O NOODLE TABLE HAND SI PREP SINK SNEEZE GUARD. _ 8 HIGH ELECTAN 1AND SINK LIP RIGI COOLER ORKTOP COOLER LCD TV LCDN WRKTOP DRINK COOLER ICE MACHINE OCD© BAG -N -130X UNDER 2 OROP.,N,COLo WELLS SNEEZE GUARD 10 WELLSSTEAM TABLE EQUIPMENT PLAN SCALE: 1/4" = P05 FIRE EXTINGUSHER NOTES 01 CLASS ABC FIRE EXTINGUISHER: EXTINGUISHERS SHALL BE CONSPICUOUSLY LOCATED AND READILY ACCESSIBLE. THE TOP OF THE EXTINGUISHER SHALL NOT BE MORE THAN 5 FT. ABOVE THE FLOOR AND THE BOTTOM OF THE EXTINGUISHER SHALL NOT BE LESS THAN 4 INCHES ABOVE THE FLOOR. EXTINGUISHERS SHALL BE INSTALLED IN ACCORDANCE WITH CLASSIFICATION, RATING, AND DISTRIBUTION REQUIREMENTS OF NFPA 10. [NFPA 1: 13.6.1.2] CLASS K FIRE EXTINGUISHER: 2 CLASS K FIRE EXTINGUISHERS SHALL BE PROVIDED FOR HAZARDS WHERE THERE IS A POTENTIAL FOR FIRES INVOLVING COMBUSTIBLE COOKING MEDIA. [NFPA 10:4.3.2] 34 MOP SINK (OSCI) 1 20" W 16" D 6" H EXISTING RELOCATED ADVANCE TABCO MODEL# 9 -OP -20 LANDLORD NOTES: MATERIAL ABBREVIATIONS: 39 SANDWICH TOP REFRIGERATOR (OSCI) 1 60" W 34-1/8" D 40-3/8" H TRUE MODEL #TSSU-60-24M-B-ST 115/60/1, 7.8 AMPS, 1/3 HP 5-15P NEMA CONFIGURATION 39a SANDWICH TOP REFRIGERATOR (OSCI) 1 48-3/8" W 34-1/8" D 40-3/8" H TRUE MODEL #TSSU-48-18M-B 115/60/1, 8.6 AMPS, 1/3 HP 5-15P NEMA CONFIGURATION 40 UNDERCOUNTER WATER HEATER (CSCI) 1 32-1/4" H 26-1/2" DIA EXISTING TO REMAIN STATE MODEL #PATRIOT PCE 50 2OLSA 50 GAL, 4.5 KW, 208V, 1PH 41 WORKTOP FREEZER (OSCI) 1 48-3/8" W 30-1/8" D 39-1/2" H TRUE MODEL #TWT -48F 115/60/1, 6.1 AMPS, 1/2 HP 5-15P NEMA CONFIGURATION 41.1 WORKTOP COOLER (OSCI) 1 72-3/8" W 31-1/8" D 39-1/2" H TRUE MODEL #TWT -72 115/60/1, 8.5 AMPS, 1/3 HP 5-15P NEMA CONFIGURATION 46 DROP-IN HAND SINK (OSCI) 2 14-1/2" W 19-3/4" D 10" H EXISTING RELOCATED KROWNE MODEL #28-1419 1/2" HOT & COLD WATER, 2" WASTE 46a DROP-IN HAND SINK (OSCI) 1 12" W 14" D 5" H EXISTING RELOCATED ADVANCE TABCO MODEL# DI -1-25 1/2" HOT & COLD WATER, 211 WASTE 46.2 SOAP DISPENSER (OSCI) 3 4-3/4" W 2-3/4" D 8-1/8" H BOBRICK MODEL #B-2111 46.3 PAPER TOWEL DISPENSER (OSCI) 3 47 3 DOOR REACH -IN COOLER (OSCI) 1 10-13/16"W 3-15/16"D 7-1/8"H 78-1/8" W 29-1/2" D 83-3/8" H BOBRICK MODEL #B-2621 TRUE MODEL #T-72 115/60/1, 9.6 AMPS, 1/2 HP 5-15P NEMA CONFIGURATION 48 2 DOOR REACH -IN COOLER (OSCI) 1 54-1/8" W 29-1/2" D 83-3/8" H TRUE MODEL #T-49 115/60/1, 5.4 AMPS, 1/2 HP 5-15P NEMA CONFIGURATION 50 UNDERCOUNTER REFRIGERATED DISPLAY (OSCI) 1 48-3/8"W 30-1/8"D 29-3/4"H TRUE MODEL #TUC -48G 115/60/1, 1/5 HP, 5 AMPS 5-15P NEMA CONFIGURATION 51 ELECTRICAL PANEL (CSCI) 2 ONE EXISTING RELOCATED AND ONE NEW SEE ELECTRICAL DRAWINGS FOR DETAILS • EQUIPMENT NOTES 1. ALL EQUIPMENT AND SIGNAGE SHALL BE PURCHASED BY THE OWNER AND INSTALLED BY THE GENERAL CONTRACTOR. 2. FOOD SERVICE AND BEVERAGE DISPENSING EQUIPMENT SHALL COMPLY W/ NSF REQUIREMENTS AND REQUIREMENTS OF LOCAL HEALTH OFFICIALS HAVING JURISDICTION. 3. INSTALLATION AND CONNECTION OF ALL FOOD SERVICE EQUIPMENT IS TO BE PERFORMED BY THE GENERAL CONTRACTOR UNLESS OTHERWISE INDICATED. 4. SHELVING UNITS SHALL BE ASSEMBLED AND SET IN PLACE BY THE GENERAL CONTRACTOR. 5. FOOD SERVICE EQUIPMENT REQUIRING AN ELECTRICAL CONNECTION IS TO BE FURNISHED W/ CORD AND PLUG UNLESS OTHERWISE INDICATED. 6. VERIFY THE ELECTRICAL AND MECHANICAL REQUIREMENTS OF FOOD SERVICE EQUIPMENT PRIOR TO INSTALLATION. 7, SINKS SHALL BE PROVIDED W/ DRAIN TAILPIECES AND FITTINGS. THE GENERAL CONTRACTOR SHALL PROVIDE SHUT-OFF VALVES, SUPPLIES AND TRAPS NECESSARY TO CONNECT SUCH SINKS. 8. PROVIDE A SHUT-OFF VALVE AT HOT AND/OR COLD WATER SERVICE TO EACH PIECE OF EQUIPMENT REQUIRING WATER CONNECTION(S). 9. PROVIDE A BACKFLOW PREVENTER AT EACH PIECE OF EQUIPMENT REQUIRING WATER CONNECTIONS. (NOT INCLUDING SINKS) NOTE: THE ABBREVIATIONS NOTED ON THE EQ. SCHEDULE: "O.S.C.I." STANDS FOR: 0= OWNER S= SUPPLIED C= CONTRACTOR I= INSTALLED Equipment package currently under review Provide Nateria Board for LL Review REVIEWED FOR CODE COMPLIANCE APP OV DEC 16 2016 City of Tukwila BUILDING DIVISION FLOOR QT -1 "DALTILE 6"X6" ARID GRAY, SURFACE ABRASIVE NON-SKID - STRAIGHT END - THIN SET INSTALL WITH CADET GRAY COLOR GROUT. SEE CONSTRUCTION NOTES AND SPECIFICATIONS FOR INSTALLATION PROCEDURES. BASE (QTB-1) COVED TILE BASE = 6" HIGH, "DAL -TILE" TO MATCH QT -1 WALLS (F.R.P.) GLASS MOSAIC , 12X12 SHEET, COLOR: LIME GREEN TUXEDO 1X6 EJDLGTX SUSAN JABLON MOSAICS: 866-939-1033 AMERICAN OLEAN, RAPPORT, AGREEABLE WHITE, RP03, 12"x 24", W/ GROUT COLOR TO MATCH TILE COLOR. CONTACT AMERICAN OLEAN AT 888.AOT.TILE "KEMLITE" FIBERGLASS REINFORCED PLASTIC PANELS COLOR; WHITE. W/WALL TRIM PIECES. CLASS "A", TO BE INSTALLED AT KITCHEN WALLS (WD -1) HARDWOOD PANELS, EQUAL TO MAZAMA HARDWOOD - PACIFIC MAHOGANY COLLECTION CONSILK / PACIFIC MAHOGANY / BUILDERS / 4 3/4 STAINLESS STEEL PANELES 1/4" TEMP GLASS 1/2" TEMP GLASS, ITCHED COUNTERS CORIAN, DESIGNER WHITE CORIAN, ROYAL RED CEILINGS RECEIVED CITY OF TUKWIA DCC 0 8 2016 PERMIT CENTER (GB -1) GYPSUM BOARD, CEILING- 5/8" TYPE "X" PAINTED PER REFLECTED CEILING PLAN MISC. PAINT METAL DOOR & FRAME ETC.: "BENJAMIN MOORE" CELU-TONE SATIN LUSTER ENAMEL; WHITE, USDA APPROVED. PAINT EXISTING SOFFIT "BENJAMIN MOORE" HERITAGE RED PM -18, EGG SHELL. DATE: 11-4-16 JOB NO: 1670 DRAWN: CHECKED: A8 nu WESTFIELD SOUTHCENTER REVISIONS TUKILA, WA 4410 W. MELROSE AVENUE TAMPA, FLORIDA 33629 TEL. 813.333.2717 FAX. 813.289.3332 SEAL \` REGISTERED ARCHITECT 1. ALL FINISHES TO BE MIN. CLASS "C". I. CLASS A: FLAME SPREAD 0-25; SMOKE -DEVELOPED 0-450 2. ALL MATERIALS USED FOR INTERIOR FINISHES AND TRIM SHALL II. CLASS B: FLAME SPREAD 26-75; SMOKE -DEVELOPED 0-450 BE CLASSIFIED IN ACCORDANCE WITH ASTM E84. III.CLASS C: FLAME SPREAD 76-200; SMOKE -DEVELOPED 0-450 FINISH INSTALLATION NOTES 1. BRING INCONSISTENCIES BETWEEN FINISH MATERIAL NOTES, FINISHES PLAN, INTERIOR ELEVATIONS & DETAILS TO THE ATTENTION OF THE ARCHITECT FOR CLARIFICATION PRIOR TO ORDERING MATERIALS OR BEGINNING INSTALLATION. 2. SUBCONTRACTORS MUST EXAMINE EACH INSTALLATION AREA FOR CONDITIONS INTERFERING WITH PROPER, TIMELY, OR ACCEPTABLE COMPLETION OF THE WORK & SHALL NOTIFY THE GENERAL CONTRACTOR OF UNACCEPTABLE CONDITIONS REQUIRING ATTENTION BEFORE FINISH MATERIAL INSTALLATION. 3. DO NOT BEGIN FINISH MATERIAL INSTALLATION BEFORE UNACCEPTABLE CONDITIONS HAVE BEEN CORRECTED IN A MANNER ACCEPTABLE TO THE GEN. CONTRACTOR & ARCHITECT FOR THAT PORTION OF THE WORK. 4. PERFORMANCE OF THIS WORK BY THE INSTALLER INDICATES ACCEPTANCE OF ALL SUBSTRATE CONDITIONS & ASSUMPTION OF RESPONSIBILITY FOR COMPLIANCE WITH MATERIAL INSTALLATION QUALITY STANDARDS. DAVID W. HIATT STATE OF WASHINGTON EQUIPMENT PLAN, SCHED. AND DETAILS SHEET NUMBER A2.0 "RUBY THAI KITCHEN" • O [V SIGN i" GLASS OVER ART MURAL. COORD. WITH OWNER. KITCHEN provide shroud for second POS • iV SNEEZE GUARD 2'-21/2" 1'-8" 14'-1 1/2" 7'-11 1/2" STOREFRONT ELEVATION SCALE: 3/8" = 1'-0" A3.0 a' GLASS OVER ART MURAL. COORD. WITH OWNER. in M 3'-3" 5'-1" / j y j // ///�' 7 ��//�'�// //��/ ��j// "RUBY THAI KITCHEN" NON ILLUMINATED iii/ / i/ // //7/// / "1//// /7/.r°/// // ,eY// // /7// STOREFRONT ELEVATION SCALE: 3/8" = 1'-0" / /,%/// //hitt, d 0 9 Q • 3/8" "J" CHANNEL CHROME FINISH 1/4" TEMP / LAMIN 9 N POLISHED S.S. ATE GLASS 0 N P I" GLASS OVER ART MURAL. COORD. WITH OWNER. //// //#'///Z i / LCD MENU BOARDS. G.C. TO SUBMIT SHOP DWGS. TOLL. FOR APPROVAL PRIOR TO INSTALLATION SNEEZE GUARD 7/7// C/1..,/ 5'-111/2" 0 7-4 4'-3" STOREFRONT ELEVATION SCALE: 3/8" = 1'-0" • T-1 //j // //73/ / fm �% // F,, // i%/%//// 1 r 1" GLASS OVER ART MURAL COORD. WITH OWNER. //.7 // ///,� / //%/�// / /17/ // `° //// /"//% / /�. //// /7// / // /i'/ //P'/Y// / 9'J"/ /// 4�/// / N r-1 r 0 i" GLASS CVER ART MURAL COORD. WITH OWNER. rn '.0 STOREFRONT ELEVATION SCALE: 3/8" = 1'-0" r 1 EXISTING EXHAUST HOOD 0 1 1 J EXISTING METAL STUD FRAMING TO REMAIN 0 i" GLASS OVER ART MURAL. COORD. WITH OWNER. STOREFRONT SECTION SCALE: 3/8" = 1'-O" FOR ALL STOREFRONT ELEVATIONS: - PROVIDE GRAPHICS FOR LANDLORD REVIEW - PROVIDE SIGN SHOP DRAWINGS FOR LANDLORD REVIEW. WATERPROOF MEMEBRANE TO INSTALLED WITH WATERPROOF MEMBRANE ON FLOOR AREA AND EXTENDING 6" UP ALL PERIMETER WALLS. • BEYOND LCD MENU BOARDS. G.C. TO SUBMIT SHOP DWGS. TOLL. FOR APPROVAL PRIOR TO INSTALLATION N 1 O N D(&-633 REVIEWED FOR CODE COMPLIANCE APPROVED DEC 16 2016 City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA DEC 0 8 2016 PERMIT CENTER DATE: 11-4-16 JOB NO: 1670 DRAWN: CHECKED: J=7 Anna WESTFIELD SOUTHCENTER REVISIONS TUKILA, WA 4410 W. MELROSE AVENUE TAMPA, FLORIDA 33629 TEL. 813.333.2717 FAX. 813.289.3332 SEAL REGISTERED ARCHITECT DAVID W.HIATT STATE OF WAIHIMOTON STOREFRONT ELEVATIONS SHEET NUMBER A3.0 Nti (kti //// //#'///Z i / LCD MENU BOARDS. G.C. TO SUBMIT SHOP DWGS. TOLL. FOR APPROVAL PRIOR TO INSTALLATION SNEEZE GUARD 7/7// C/1..,/ 5'-111/2" 0 7-4 4'-3" STOREFRONT ELEVATION SCALE: 3/8" = 1'-0" • T-1 //j // //73/ / fm �% // F,, // i%/%//// 1 r 1" GLASS OVER ART MURAL COORD. WITH OWNER. //.7 // ///,� / //%/�// / /17/ // `° //// /"//% / /�. //// /7// / // /i'/ //P'/Y// / 9'J"/ /// 4�/// / N r-1 r 0 i" GLASS CVER ART MURAL COORD. WITH OWNER. rn '.0 STOREFRONT ELEVATION SCALE: 3/8" = 1'-0" r 1 EXISTING EXHAUST HOOD 0 1 1 J EXISTING METAL STUD FRAMING TO REMAIN 0 i" GLASS OVER ART MURAL. COORD. WITH OWNER. STOREFRONT SECTION SCALE: 3/8" = 1'-O" FOR ALL STOREFRONT ELEVATIONS: - PROVIDE GRAPHICS FOR LANDLORD REVIEW - PROVIDE SIGN SHOP DRAWINGS FOR LANDLORD REVIEW. WATERPROOF MEMEBRANE TO INSTALLED WITH WATERPROOF MEMBRANE ON FLOOR AREA AND EXTENDING 6" UP ALL PERIMETER WALLS. • BEYOND LCD MENU BOARDS. G.C. TO SUBMIT SHOP DWGS. TOLL. FOR APPROVAL PRIOR TO INSTALLATION N 1 O N D(&-633 REVIEWED FOR CODE COMPLIANCE APPROVED DEC 16 2016 City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA DEC 0 8 2016 PERMIT CENTER DATE: 11-4-16 JOB NO: 1670 DRAWN: CHECKED: J=7 Anna WESTFIELD SOUTHCENTER REVISIONS TUKILA, WA 4410 W. MELROSE AVENUE TAMPA, FLORIDA 33629 TEL. 813.333.2717 FAX. 813.289.3332 SEAL REGISTERED ARCHITECT DAVID W.HIATT STATE OF WAIHIMOTON STOREFRONT ELEVATIONS SHEET NUMBER A3.0 SEE EQUIPMENT PLAN VARI HOT WELLS, SEE EQUIPMENT PLAN I J L T —J IWO J TO FLOOR SINK --\ SEE PLUMBING (F.R.P.) PANELS OVER 3/4" F.R.T. PLYWOOD STAINLESS STEEL COUNTER CUSTOM FABRICATED GLASS SNEEZE GUARD CONTINUOUS SILICONE SEALANT (SSM -1) SOLID SURFACE MATERIAL PER ELEVATIONS (QTB-1) BASE, TYP. OVER 5/8" CEMENT BED • N fV FRT WOOD BLOCKING UNDER COUNTER LED LIGHT STRIP, SEE ELECTRICAL DRAWING 2" METAL STUDS @ 1'-0" O.C. 3/4" FRT PLYWOOD SECURED TO 1-7/8" MTL. CHANNEL FINISH PER ELEVATIONS 5/5 ANGLE STAINLESS STEEL BASE OVER CEMENT BD. O SECTION @ STEAM TABLE SCALE: 1-1/2" = 1'-0" (WD 1) OVER 1 LAYER OF 3/4" PLYWOOD SSM -2) OVER 1 LAYER OF PLYWOOD T-2 9 LOW WALL SECTION SCALE: 1-1/2" = 1'-0" 1/4" BENT STEEL PLATE STIFFENER 12" HIGH. 3" WIDE, 4" LEG. @ 3'-0" O.C. SECURE TO STUD W/2 #10 SCREWS AND TO FLOOR W/ 1/4'10 EXPANSION BOLT VERIFY WITH OWNER SSM -2) OVER 1 LAYER OF PLYWOOD :-i 3 5/8" METAL STUDS @ 16" O.C. (WD -1) OVER 1 LAYER OF 3/4" PLYWOOD SS -1 OVER 1 LAYER OF CEMENT BD. 0 ‘Zr SECTION @ EXTERIOR TV BOARDS SCALE: 1-1/2" = 1'-0" r • • SEE FLOOR PLAN 1'-6" 11 1/2" • WHITE PLASTIC LAMINATE ON ALL INTERIOR CABINETS J FRT WOOD BLOCKING AS REQUIRED • 0 1-4N SECTION @ SODA MACHINE SCALE: 1-1/2" = 1'-0" T-2 QT -1 SSM -2) OVER 1 LAYE1 OF PLYWOOD "RUBY THAI KITCHEN" NON ILLUMINATED 3 5/8" METAL STUDS @ 16" O.C. (SSM -2) OVER 1 LAYER OF PLYWOOD • (WD -1) OVER 1 LAYER OF 3/4" PLYWOOD STAINLESS STEEL ANGLE ( 55-1 OVER 1 LAYER OF CEMENT BD. 0 in 1/4" BENT STEEL PLATE STIFFENER 12" HIGH. 3" WIDE, 4" LEG. @ 3'-0" O.C. SECURE TO STUD W/2 #10 SCREWS AND TO FLOOR W/ 1/4"� EXPANSION BOLT SSM -1) SHROUD AROUND SODA MACHINE SSM -1) SSM -1) OVER 2 LAYERS OF PLYWOOD SECTION @ EXTERIOR TV BOARDS SCALE: 1-1/2" = 1'-0" (SSM -2) WATERPROOF MEMEBRANE TO INSTALLED WITH WATERPROOF MEMBRANE ON FLOOR AREA AND EXTENDING 6" UP ALL PERIMETER WALLS. SEE FLOOR PLAN ft) CASH REGISTER 11 1/2" i QT -1 KEY LOCK DRAWER WHITE PLASTIC LAMINATE ON ALL INTERIOR CABINETS FRT WOOD BLOCKING AS REQUIRED SECTION @ CASH REGISTER SCALE: 1-1/2" = 1'-0" O lV SSM 1 BEYOND STAINLESS STEEL BACK SPLASH (SSM -2) SHROUD SSM -2) --(SS M-2) OVER 2 LAYERS OF PLYWOOD CUSTOM FABRICATED STAINLESS STEEL CABINETS \I T-1 0 r 7-1 t (GL -2 RECESS GLASS IN SSM -1 (SSM -1) `I' (SSM -i) \ OVER1LAYEROF PLYWOOD 3-5/8" METAL STUDS @ 16" O.C. OVER 1 LAYER OFb PLYWOOD SS -1 OVER 1 LAYER OF CEMENT BD. SECTION @ 3 COMP SINK SCALE: 1-1/2" = 1'-0" 1/4" BENT STEEL PLATE STIFFENER 12" HIGH. 3" WIDE, 4" LEG. @ 3'-0' O.C. SECURE TO STUD W/2 #10 SCREWS AND TO FLOOR W/ 1/4"� EXPANSION BOLT i REVIEWED FOR CODE COMPLIANCE APPROVED DEC 16 2016 City of Tukwila BUILDING DIVISION RECEIVED CITY OF ThKWILA DEC 0 8 2016 PERMIT CENTER • CABINET CONTRACTOR TO FIELD VERIFY ALL NECESSARY DIMENSIONS AND WALL ANGLES BEFORE FABRICATION OF CABINETS. S.S. CABINET DESIGN SHOWN IN THESE DRAWINGS IS DIAGRAMATICAL ONLY. CABINET CONTRACTOR TO COORDINATE WITH OWNER, THROUGH THE GC FOR ALL DESIGN RELATED ITEMS PERTAINING TO S.S. CABINETRY (I.E. HEIGHTS, SHELVES, DRAWERS, DOORS, LOCKS, ETC.). FULL SHOP DRAWINGS WILL BE REQUIRED FOR APPROVAL BY OWNER AND GC. • CABINET CONTRACTOR IS COMPLETELY RESPONSIBLE FOR COORDINATION W/ALL TRADES AND EQUIPMENT SUPPLIER, FOR OBTAINING THE NECESSARY EQUIPMENT CUT SHEETS FOR EACH PIECE OF EQUIPMENT WHICH DIRECTLY EFFECTS THE CABINET FABRICATION, UTILITY REQUIREMENTS, CUT OUT DIMENSIONS, ETC.. O STOREFRONT IS FLOOR SUPPORTED W/NO ATTACHMENT TO LANDLORD'S DEMISING PIERS OR BULKHEADS. • ALL PLYWOOD TO BE MARINE GRADE. DATE: 11-4-16 JOB NO: 1670 DRAWN: CHECKED: 1==zi A8f21 REVISIONS TUKILA, WA 4410 W. MELROSE AVENUE TAMPA, FLORIDA 33629 TEL. 813.333.2717 FAX. 813.289.3332 SEAL REGISTERED ARCHITECT DAVID W.HIATT STATE OF WASHINGTON COUNTER DETAILS SHEET NUMBER A410 ( QT -1 SSM -1 SSM -1) SEE PLAN RECESSED CONDIMENT HOLDERS, VERIFY SIZE WITH EQUIPMENT SUPPLIER FRT WOOD BLOCKING AS REQUIRED SSM -1 SECTION @ CONDIMENT HOLDERS SCALE: 14/2" = 1'-0" 0 rn (SSM -1) OVER 2 LAYERS OF PLYWOOD VARIES (SSM -1) OVER 1 LAYER OF FRT PLYWOOD OVER 5/8" TYPE 'X' GYP. BD. SS -1 OVER 5/8" TYPE 'X' GYP. BD. JL OVER 1 LAYER OF FRT PLYWOOD SSM -1) rn LCD TV VERIFY WITH OWNER • 1-1 9 cv m SSM -1 T-2 OVER 5/8" TYPE 'X' GYP. BD. 3 5/8" METAL STUDS @ 16" O.C. quarry tile is not to be used on storefront - provide alternative ie. SS or Tile alternative iD m SS -1 OVER 1 LAYER OF 0 CEMENT BD. r ZD SECTION @ INTERIOR TV BOARDS SCALE: 1-1/2" = 1'-0" CONTINUOUS RECESSED LED LIGHT 2-1/2" METAL STUDS STAINLESS STEEL TRIM 5/8" GYP. BD. CONTINUOUS 2-1/2" X 2-1/2" METAL ANGLE STAINLESS STEEL TRIM RECESSED LIGHT FIXTURE, SEE ELECTRICAL. EXISTING 3-5/8" METAL STUDS EXISTING EXHAUST HOOD-\ SECTION © LIGHT COVE LEDGE SCALE: 3" = 1'-0" WATERPROOF MEMEBRANE TO INSTALLED WITH WATERPROOF MEMBRANE ON FLOOR AREA AND EXTENDING 6" UP ALL PERIMETER WALLS. ti FLUSH \.\ DOUBLE ACTING SURFACE MOUNTING ,SPRING PIVOT HINGE. BOMMER. MODEL# BOM -7112-633 SECTION @ EXIT GATE SCALE: 3" = 1'-0" FLUSH VARIES SEE PLAN QT -1 CLEAR SIL CONE AT INTERSECTION STAINLESS STEEL CABINET SHOWN DASHED. SEE EQUIPMENT PLAN AND SCHEDULE. CABINET SECTION SCALE: 1-1/2" = 1'-O" A4.1 (SSM -2 r1 SEE FLOOR PLAN I L ,• I I I I 1 1 CASH REGISTER 11 1/2" i0 Lf; r4 KEY LOCK DRAWER QT -1 WHITE PLASTIC LAMINATE ON ALL INTERIOR CABINETS FRT WOOD BLOCKING AS REQUIRED SECTION @ CASH REGISTER SCALE: 1-1/2" = 1'-0" 0 fV SSM -1) SHROUD SSM -1) SSM -1) OVER 2 LAYERS OF PLYWOOD SEE PLAN WHITE PLASTIC LAMINATE ON ALL INTERIOR CABINETS FRT WOOD BLOCKING AS REQUIRED SECTION @ NOODLE POS SCALE: 1-1/2" = 1'-0" \ A4.1 W iV • SSM -2) (SSM -2) OVER 2 LAYERS OF PLYWOOD a 3'-0" 1 EXIT GATE ELEVATION SCALE: 3/4" =1'-0" PROVIDE KEYED SECURITY LOCK SS -1 d I�- 0335 DATE: .11-4-16 JOB NO: 1670 DRAWN: CHECKED: WESTFIELD SOUTHCENTER REVISIONS TUKILA, WA 4410 W. MELROSE AVENUE TAMPA, FLORIDA 33629 TEL. 813.333.2717 FAX. 813.289.3332 o CABINET CONTRACTOR TO FIELD VERIFY ALL NECESSARY DIMENSIONS AND WALL ANGLES BEFORE FABRICATION OF CABINETS. S.S. CABINET DESIGN SHOWN IN THESE DRAWINGS IS DIAGRAMATICAL ONLY. CABINET CONTRACTOR TO COORDINATE WITH OWNER, THROUGH THE GC FOR ALL DESIGN RELATED ITEMS PERTAINING TO S.S. CABINETRY (I.E. HEIGHTS, SHELVES, DRAWERS, DOORS, LOCKS, ETC.). FULL SHOP DRAWINGS WILL BE REQUIRED FOR APPROVAL BY OWNER AND GC. o CABINET CONTRACTOR IS COMPLETELY RESPONSIBLE FOR COORDINATION W/ALL TRADES AND EQUIPMENT SUPPLIER, FOR OBTAINING THE NECESSARY EQUIPMENT CUT SHEETS FOR EACH PIECE OF EQUIPMENT WHICH DIRECTLY EFFECTS THE CABINET FABRICATION, UTILITY REQUIREMENTS, CUT OUT DIMENSIONS, ETC.. O STOREFRONT IS FLOOR SUPPORTED W/NO ATTACHMENT TO LANDLORD'S DEMISING PIERS OR BULKHEADS. O ALL PLYWOOD TO BE MARINE GRADE. REVIEWS[ OR 7E COMPLiAIl10E APPPOVEO DEC 16 2016 City of Tukwila BUILDING DI:V!SION RECEIVED CITY OF TUKWILA DEC 0 8 2016 PERMIT CENTER COUNTER DETAILS SHEET NUMBER A4.1 EXIST. A-33,35 A-2 B-10 B-11� B-5 B-12 A'f . .. fir 111, .v!Ite ���. �... fin!'' ��.�-- 411- El 41D I I I I 1 1 1 1 A-39 VIA T/C TIE TO A-14 VIA T/C A-25,27 TIE TO A-11,13,15 A-14 VIA T/C A-3 ELECTRICAL POWER PLAN SCALE: 11 = 1'-0" [EXIST. r _ , EXIST. EF -1 ON 1 i A-22,24,26 ROOF I -- -In THRU EXIST. HOOD PANEL 0 EXIST. WP GFI EXIST. A-38 EXIST. r 1 SF -1 ON ROOF J -I \, y EXIST. A-28,30,32 THRU EXIST. HOOD PANEL SYMBOLS GENERAL NOTES: KEY NOTES: RECESSED NIGHT LT (N/L) DUPLEX RECEPTACLE WITH 120 V, 20 AMPERE RATING. HEIGHT 16" TO BOTTOM UNLESS NOTED OTHERWISE. (TYP.) GFI DUPLEX W/GRND F. INTERRUPTER AT COUNTER SHALL BE 42" AFF TO BOTTOM UNLESS NOTED OTHERWISE &IG DUPLEX W/ISOL. GRND CONDUCTOR ATA HEIGHT TO THE BOTTOM AS NOTED. 0 JUNCTION BOX DISCONNECT SWITCH TELEPHONE JACK ELECTRICAL POWER PANEL TWO WAY SWITCH W H1 WATER HEATER MANUAL PULL STATION - 270 -SPO 42" A.F.F. ©r HORN/STROBE-792-7A-006 80" A.F.F. HEAT DETECTOR -281B 0 REFER TO THE CODED NOTE NUMBER. CONCEALED IN WALL, CEILING OR UNDER CONDUIT RUN CONSISTING OF: Z - GROUND CONDUCTOR III - SMALL LINES INDICATE POWER NON GROUNDED CONDUCTORS. - BIG LINE INDICATES NEUTRAL CONDUCTOR "C" TYPE UNDER COUNTER COVE LIGHT A-40 VIA T/C "C" TYPE SOFFIT LEDGE COVE LIGHT TIE TO A-14 VIA T/C "C" TYPE UNDER COUNTER COVE LIGHT ELECTRICAL LIGHTING PLAN SCALE: 1" = 1'-0" 1. CONTRACTOR SHALL REVIEW THE SPECIFICATIONS, GENERAL NOTES, KEY NOTES, ELECTRICAL PLANS AND THE LANDLORD DESIGN CRITERIA BEFORE BIDDING AND STARTING ANY CONSTRUCTION WORK. 2. ALL INSTALLATION SHALL COMPLY WITH THE REQUIREMENTS OF THE DESIGN DOCUMENTS, LANDLORD DESIGN CRITERIA AND N.E.C. REQUIREMENTS. 3. CONTRACTOR SHALL VERIFY AND USE EXISTING POWER SUPPLY, EQUIPMENT, POWER PANELS, XFRMR AND FEEDERS TO COMPLY WITH PANEL SCHEDULES. REFER TO KEY NOTE #19. 4. CONTRACTOR VERIFY EXISTING AND FURNISH AND INSTALL NEW WIRING AS SHOWN ON THE ELEC. PLANS, PANEL SCHEDULES AND RISER DIAGRAM. ALL EXISTING AND NEW WIRING SHALL BE IN COMPLIANCE WITH N.E.C. TABLE 310-16. 5. PULL STRINGS SHALL BE PROVIDED IN ALL EMPTY CONDUIT. FOR TELEPHONE AND LOW VOLTAGE SYSTEM. 6. INTERIOR TELEPHONE WIRING SHALL INCLUDE FURNISHING AND INSTALLING ALL TELEPHONE JACKS, AND COVER PLATES AS REQUIRED. COORDINATE WITH THE TENANT. 7. LABEL ALL ELECT. EQUIPMENT WITH ENGRAVED BAKELITE NAMEPLATE OR EMBOSSED PLASTIC NAME STRIP. LABEL ALL PANELS AS SHOWN ON THE RISER DIAGRAM. 8. FURNISH ATYPE WRITTEN CIRCUIT DIRECTORY CARD FOR ALL PANELS, LISTING ALL USED AND SPARE CIRCUITS. 9. CONTRACTOR SHALL VERIFY AND COORDINATE ALL ELECTRICAL REQUIREMENTS AND LOCATIONS OF ALL HVAC EQUIPMENT PRIOR TO INSTALLATION. 10. ALL OUTLET AND SWITCHES COVER PLATES SHALL BE STAINLESS STEEL. ALL OUTLET BOXES SHALL BE MOUNTED FLUSH IN WALLS AND SHALL BE MOUNTED AT HEIGHT AS INDICATED ON THE EQUIP. PLAN. COORDINATE ALL LOCATIONS WITH EQUIPMENT INSTALLATION AND ARCHITECTURAL DRAWINGS. 11. ALL ELECTRICAL DEVICES AND EQUIPMENT SHALL BE EFFECTIVELY GROUNDED IN ACCORDANCE WITH N.E.C. REQUIREMENTS. ALL BRANCH CIRCUITS SHALL HAVE A SEPARATE GREEN INSULATED GROUND WIRE IN EACH CONDUIT RUN. 12. CONTRACTOR SHALL BE RESPONSIBLE FOR ALL ELECTRICAL CONNECTIONS UNLESS NOTED OTHERWISE. 13. CONTRACTOR SHALL BE RESPONSIBLE FOR COMMUNICATION WITH THE PROPERTY OWNER'S PERSONNEL TO REVIEW CONTRACT DOCUMENTS PRIOR TO INSTALLATION. 14. CONTRACTOR TO SEAL ALL WALL PENETRATIONS IN AN APPROVED MANNER TO INSURE THE FIRE RATING INTEGRITY OF THE INVOLVED AREAS. 15. COORDINATE FINAL INSTALLATION REQUIREMENTS WITH PROPER AUTHORITIES. AND LANDLORD'S MANAGER. 16. CONTRACTOR, UPON COMPLETION OF HIS WORK , SHALL BE RESPONSIBLE TO PROVIDE ANY AND ALL CERTIFICATIONS. 17. CONTRACTOR SHALL COMPLY WITH THE LANDLORD'S DESIGN CRITERIA FOR ELECTRICAL AND FIRE ALARM SYSTEMS. MAKE NECESSARY CONNECTIONS BETWEEN TENANT'S FIRE DETECTING DEVICES AND THE LAND LORD'S FIRE ALARM STATION. 18. ALL CONDUIT RUNS ABOVE CEILING SHALL BE PARALLEL OR PERPENDICULAR TO THE COLUMN LINES. 19. ALL CABLES AND WIRES SIZES SHALL COMPLY WITH N.E.C. TABLE 310-16, 2008. MINIMUM SIZE OF CONDUCTOR SHALL BE #12 AWG CU. NO. 10 WIRES SHALL BE USED IN PLACE OF #12 FOR CIRCUITS LONGER THAN 100 FEET FROM PANEL TO LOAD. ALUMINUM CONDUCTOR SHALL NOT BE PERMITTED. WIRE INSULATION SHALL BE THHN OR THWN. 20. ALL INTERIOR WIRING SHALL BE CONCEALED AND IN GAL. STEEL OR EMT COND. AND IN COMPLIANCE WITH THE N.E.C. AND LAND LORD'S DESIGN CRITERIA. 21. CONTRACTOR MAY USE FLEXIBLE CONDUIT FROM JUNCTION BOX TO THE LIGHTING FIXTURE, BETWEEN LIGHTING FIXTURES, AND TO OTHER DEVICES PROVIDED THE LENGTH OF THE FLEX. CONDUIT IS NOT MORE THAN 6 FEET. 22. MC CABLES SHALL NOT BE USED FOR HOME RUN CIRCUITS AND FOR THE WIRING WITHIN PARTITION OR DEMISING WALL CONSTRUCTION. ALL IN -WALL CONCEALED WIRING MUST BE RUN IN RIGID CONDUITS. 23. THE GROUND ON THE SEPARATELY DERIVED SERVICE SHALL BE BONDED TO THE BUILDING STEEL AND TO THE INCOMING COLD WATER METAL PIPING WITH CAD WELD CONNECTION. REFER TO KEY NOTE #22. 24. ALL BREAKERS IN ALL PANELS SHALL BE BOLTED THERMAL MAGNETIC TYPE. TWO (2) AND THREE (3) POLE MOLDED CASE CIRCUIT BREAKERS SHALL BE WITH COMMON TRIP. 25. UNLESS NOTED OTHERWISE, WIRE AND CABLE SIZES SHALL BE IN COMPLIANCE WITH BRANCH CIRCUIT FEEDER CIRCUIT SCHEDULE, RISER DIAGRAM AND THE N.E.C. TABLE 310-16. 26. ROMAX, TYPE AC AND NM CABLES SHALL NOT BE PERMITTED. 27. CONDUCTORS SHALL BE COPPER PER LL CRITERIA. 28. ALL BREAKERS USED FOR LIGHTING CIRCUITS SHALL BE CONTINUOUS DUTY LIGHT SWITCHING RATING. O PROVIDE LOCK TAB AT CIRCUITS WHICH FEED POWER TO EXIT, NIGHT AND EMERG. LIGHTS IN "ON" POSITION. NIGHT. LIGHTS SHALL BE CONTROLLED BY A KEYED SWITCH AND ALL EXIT AND EMERGENCY LIGHTS SHALL BE WIRED AHEAD OF ANY LOCAL SWITCHES. O CONTRACTOR MUST COORDINATE AND SUBMIT CUT SHEETS OF ALL NEW LIGHT FIXTURES AND MUST GET APPROVAL FROM THE OWNER OF ALL LIGHT FIXTURE MODEL NUMBERS BEFORE PURCHASING ANY NEW LIGHT FIXTURES. O CONTRACTOR SHALL PROVIDE A NEW TIME CLOCK (T/C). INSTALL JUNCTION BOXES, RECESSED OUTLETS AND SWITCHES FOR THE MENU BOARD AND STORE SIGN CIRCUITS AS REQUIRED. O ROUTE ALL LIGHTING/SIGN CIRCUITS THROUGH A WPM -STOPPER 8 RELAY PEANUT PANEL LP8S-8-G-115 AND PROVIDE AS -100-W SWITCHES FOR ALL LIGHTING SWITCHES. (FOR TIME OF DAY CONTROL AND LOCAL OVERRIDE ) 0 VERIFY EXISTING OR INSTALL NEW SWITCH LEG AS SHOWN. EACH SWITCH DESIGNATION WHICH CONTROL THE SPECIFIC LIGHT IS MARKED ON THE PLAN. OINSTALL UNDER COUNTER AND SOFFIT COVED LED LIGHT PER LIGHTING SCHEDULE, LOW VOLTAGE POWER SUPPLY SHALL BE LOCATED WITHIN AN ACCESSIBLE LOCATION. • PROVIDE A MINIMUM 1/2" CONDUIT W/WIRE FROM TELEPHONE OUTLET BACK TO TELEPHONE BOARD. THIS IS TYPICAL FOR ALL TELEPHONE OUTLETS. O CONTRACTOR SHALL COORDINATE WITH LANDLORD AND INSTALL NEW TELEPHONE BOARD AS REQUIRED. EXTEND EXISTING TELEPHONE CONDUIT AND CABLE TO TENANT'S TEL. BD "TTB". COORDINATE ALL TELEPHONE REQUIREMENTS WITH TENANT. CONTRACTOR SHALL BE RESPONSIBLE FOR PROVIDING ALL CABLES AND DATA/TEL. OUTLETS. THE TELEPHONE SYSTEM SHALL BE COMPLETE AND FUNCTIONAL. 0 ALL OUTLETS WITHIN 6' OF ANY SINK SHALL BE GFI OUTLETS. ALL KITCHEN AREA OUTLETS SHALL BE WITH GFI TO COMPLY WITH N.E.C. STD. #210.8(B)(2). TO ECONOMIZE THE COST THE CONTRACTOR SHALL INSTALL FIRST OUTLET AT WHICH THE HOME RUN IS CONNECTED, WITH GFI AND ALL OTHER DOWN STREAM OUTLET NORMAL WITHOUT GFI. 0 THE CONTRACTOR SHALL COORDINATE WITH LANDLORD AND DETERMINE WHAT KIND OF LIFE SAFETY AND FIRE ALARM DEVICES ARE REQUIRED BEFORE BIDDING FOR THE PROJECT. USE EXISTING OR FURNISH AND INSTALL NEW FA DEVICES AS REQUIRED, IN COMPLIANCE WITH THE POWER PLAN AND ANSUL WIRING DIAGRAM, LANDLORD'S CRITERIA, NFPA AND LATEST APPLICABLE CODE REQUIREMENTS. TIE TENANT'S FA SYSTEM TO THE BASE BUILDING FA SYSTEM AS REQUIRED. 0 PROVIDE SHUNT TRIP CIRCUIT BREAKER TO ALL EQUIPMENT UNDER THE HOOD. INTERLOCK SHUNT TRIP W/ HOOD ANSUL SYSTEM. 0 THE CONTRACTOR SHALL COORDINATE WITH THE KITCHEN APPLIANCES CONTRACTOR AND PROVIDE ALL HARDWARE AND CONNECTIONS AS REQUIRED. THIS IS TYPICAL. 0 FURNISH AND INSTALL POWER CIRCUITS AND JUNCTION BOXES FOR STEAM TABLES (#3 & #3.1), SOUP/NOODLE WARMER (#4), SNEEZE GUARD LIGHTS (#5), AND COMBI OVEN (#20). DETERMINE EXACT LOCATION OF JUNCTION BOXES AT SITE WITH TENANT. MAKE ALL CONNECTIONS AS REQUIRED. 14 CONTRACTOR SHALL COORDINATE WITH KITCHEN EQUIP. CONTRACTOR AND ROUTE 208V, 10, CIRCUIT WITH NEUTRAL AND GRND CONDUCTORS FOR ICE MACHINE. FURNISH JB OR SPECIAL OUTLET AS REQ'D AND MAKE NECESSARY CONNECTIONS OF REMOTE CONDENSER. 0 CONTRACTOR SHALL COORDINATE WITH KITCHEN AND REFRIGERATION CONTRACTORS AND DETERMINE EXACT RATING OF ALL EQUIPMENT AND TYPE OF REQUIRED POWER LEAD CONNECTIONS AT EACH EQUIP. MUST ADJUST SIZE OF BREAKERS IF OR AS REQUIRED. THIS IS O TYPICAL. 16 VERIFY EXISTING POWER SUPPLY TO EXISTING HOOD AND ANSUL PANELS. VERIFY EXISTING POWER SUPPLY AND EXISTING DISC. SWITCHES FOR EXISTING EXHAUST AND SUPPLY FANS. VERIFY EXISTING WP, GFI OUTLET ON ROOF NEAR FANS. MAKE ALL CONNECTIONS AS REQUIRED. 17 ALL CONDUIT PENETRATIONS THROUGH CASEWORK SHALL BE CLEAN, TIGHT AND SEALED WITH 0 WHITE SILICONE. THIS IS TYPICAL. 0 PROVIDE KEY -LOCK TABS AT THESE CIRCUITS. ROUTE CASH REGISTER CIRCUITS WITH AN ISOLATED GROUND CONDUCTORS. 19 REUSE EXISTING 200 AMP, 120/208V, 3PH POWER SUPPLY IN COMPLIANCE WITH THE RISER DIAGRAM, PANEL SCHEDULES, AND AS DESCRIBED BELOW: a) VERIFY THAT ALL EXISTING EQUIPMENT AT THE LANDLORD'S METER CENTER INCLUDING DISC. SWITCH, METER, FEEDERS AND CONDUITS ARE IN COMPLIANCE WITH RISER DIAGRAM AND N.E.0 APPLICABLE CODE. IF NOT UPGRADE THEM PER RISER DIAGRAM. b) RELOCATE AND REUSE EXISTING PANEL "A" AND FURNISH AND INSTALL NEW SUBPANEL "B" IN COMPLIANCE WITH THE RISER DIAGRAM AND PANEL SCHEDULES. ALL BREAKERS IN ALL PANELS SHALL BE BOLTED TYPE BREAKERS. REFER TO FOOT NOTES AT PANEL SCHEDULES. c) THE GROUNDING SYSTEM SHALL BE INSTALLED TO COMPLY WITH N.E.C. STD #250 REQUIREMENTS. ALL EQUIPMENT SHALL BE GROUNDED IN COMPLIANCE WITH N.E.C. STD. #250, 2008. AND UL REQUIREMENTS. BRANCH CIRCUIT FEEDER SCHEDULE AMP/POLE CONDUCT. GND. CONDUCT. CON. 15A/1P OR 15A/2P (2) #12 #12 1/2" 20A/1P OR 20A/2P (2) #12 #12 1/2" 15A/3P OR 20A/3P (3) #12 #12 1/2" 25A/1P OR 25A/2P (2) #10 #10 3/4" 30A/1P OR 30A/2P (2) #10 #10 3/4" 25A/3P OR 30A/3P (3) #10 #10 3/4" 35A/1P OR 35A/2P (2) #8 #10 3/4" 40A/1P OR 40A/2P (2) #8 #10 3/4" 35A/3P OR 40A/3P (3) #8 #10 3/4" 45A/1P OR 45A/2P (2) #6 #10 1" 50A/1P OR 50A/2P (2) #6 #10 1" 45A/3P OR 50A/3P (3) #6 #10 1" 60A/1P OR 60A/2P (2) #4 #8 1" 60A/3P (3) #4 #8 1 1/4" 70A/3P OR 80A/3P (3) #4 #8 1 1/4" 90A/3P (3) #3 #8 1 1/4" 100A/3P OR 110A/3P (3) #2 #6 1 1/2" 125A/3P (3) #1 #6 - PROVIDE BRANCH CIRCUIT FEEDERS AS NOTED ABOVE UNLESS NOTED OTH bi6-03 RECEIVED CITY OF TUKWILA LIGHTING FIXTURE SCHEDULE 0000 DEC 08 2016 PERMIT 1 1/2" DATE: 11-4-16 JOB NO: 1670 DRAWN: CHECKED: TYPE SYMBOL DESCRIPTION QTY. MAN U FAC. CATALOG LAM P MTG. VOLT REMARKS LAMPS/ FIXT. BALLASTS BALLAST/ FIXT. TOTAL WATT C FLEXIBLE LINE VOLTAGE LED LINEAR STRIP 70 FT. INFINA DL -AC -FLEX -30 LED 3000K WARM WHITE COVED 120 PROVIDE ALL REQ'D. HARDWARE 4W/FT. E RECESSED DOWN LIGHT 29 LITHONIA 6G1MW LED 10.8 WATT LED (620 LUMENS) RECESSED 120 10%-100% DIMMING 1 EPARATE RMITAM G RECESSED DOWN LIGHT 31 JUNO IC1 LEDG4-3K- 1 14W -WH 14 WATT LED NOTES: 0 ELECTRICAL CONTRACTOR TO INQUIRE ABOUT LOCAL REBATES ON LIGHT FIXTURES. 0 INSTALLATION OF LIGHT FIXTURES SHALL BE ACCORDING TO MANUFACTURER'S RECOMMENDATIONS AND ACCORDING TO CODE REQUIREMENTS. D 1 10.8 4 PPROVAL LQUIRED 0 ALL LAMPS IN FLUORESCENT LIGHT FIXTURES TO BE SYLVANIA UNLESS NOTED OTHERWISE. OPROVIDE LIGHT TUBE COVERS, LENSES, ETC., AS REQUIRED TO PROTECT FOOD SERVICE AREA. z w z U Fmui 1=1 As n!1 WESTFIELD SOUTHCENTER REVISIONS TUKILA, WA 4410 W. MELROSE AVENUE TAMPA, FLORIDA 33629 TEL. 813.333.2717 FAX. 813.289.3332 SEAL AGISTERED RCHITECT DAVID W HIATT � STATE OF WASHINGTON\ ELECT. POWER & LIGHTING PLANS AND NOTES SHEET NUMBER E1.0 EXIST. PANEL "A"T 1 TENANT U ISCHEDULE MCB: 150 AMP A.I.C.: 22,000 AMP BLDG: RUBY THAI KITCHEN MLO: N/A VOLTS: 120/208 V PHASE: 3, S/N WIRE: 4 MTD: RECESS SPACE WITH ISO. & EQUIPMENT GROUND BUSSES MARK ITEM/RESPONSIBILITY QNTY. DIMS SPECIFICATIONS: REMARKS: ELECTRICAL I' ROOM SPACE 2 CASH REGISTER (OSCI) 2 16.6" W 16.8" D �� 11.7 H SHARP MODEL #ER -A530 WITH SPILL -PROOF KEYBOARD, 120 V BRKR KVA PH LOAD CIR PHASE CIR KVA PH LOAD BRKR I L T/C 7DAY 24 HRS TME CLOCKT/C DESCRIPTION OF LOAD AMP P OA 0B OC NO A B C NO OA OB OC P AMP DESCRIPTION OF LOAD (1)(2) R CASH REGEISTER (IG) (#2) 20 1 0.30 1 ® 2 1.12 1 20 3 DOOR REACH -IN COOLER (#47) K 3 10 WELLS STEAM TABLE (OSCI) 1 VARIES SEE PLAN STAINLESS STEEL STUDIO. CUSTOM FABRICATED, SEE SECTIONS. 208V, 3PH, 12 KW, 50 AMP & 208V, 1PH, 30 KW, 20 AMP r -I J. A, J. CASH REGEISTER (IG) (#2) NI, �, 0.30 3 ® 4 SPACE _ O (�� /� EXIST. RE LOC. EXIST. PANEL19-5/8" 11A11 200 AMP O NEW SUBPANEL 1r B11 60 AMP 3 0 O O K SOUP/NOODLE WARMER (#4A) 25 3 3.00 5 @ 6 3.34 3 60 SUBPANEL "B" T (6) 3.1 2 WELLS DROP-IN REFRIGERATED COLD PAN (OSCI) 1 29-3/4" W 24"DNEMA H ATLAS METAL MODEL #WCM-2 3.9 AMPS. -120V -1/5HP CUT-OUT REQUIRED: 22-1/4" D x 28" W 15P 3/4" I.D. 3.00 7 ® 8 3.55 i 5, �, 3.00 9 ® 10 3.38 v �, i �, STEAM TABLE (#3) 50 3 4.00 11 ® 12 0.75 1 20 LIGHTS (G), (E) & COVE (C) (T/C) L (4) 4 SOUP/NOODLE WARMER (OSCI) 1 VARIES SEE PLAN STAINLESS STEEL STUDIO. CUSTOM FABRICATED. 208V, 3PH, 9 KW, 25 AMP 4.00 13 ® 14 1.00 J, E , U.C. (C) & S.G. (#5) (T/C) J, v v v 4.00 15 ® 16 SPACE 4-#3/0, CU, 1-#6, CU, GRND, MCB 120/208V �_ MLO 120/208V (3) COMBI OVEN (#20) 35 3 3.70 17 ® 18 0.96 2 20 ICE MACHINE (#29) K 5 SNEEZE GUARD (OSCI) 2 VARIES SEE PLAN CUSTOM FABRICATED WITH LIGHT FIXTURE 120 V FOR LIGHT FIXTURE 3.70 19 0 20 0.96 A, 4, v v v v v v 3.70 21 ® 22 1.00 3 20 EXIST. EF -1 M (5) OO2 IN 2" C. - --T --� ---� -I 1 6 UNDERCOUNTER BAG -IN BOX (OSCI) 1 COKE CO. RESERVED FOR SHUNT TRIP 23 ® 24 1.00 K STEAM TABLE (#3) 20 2 1.50 25 ® 26 1.00 v �, EXIST. 75 KVA 1 _ .1._- --I XFRMR480V-120/208V 1-- � EXIST. � O 1 75 1 1 TO EXIST. METER i 1 AND DISC. SW. AT L_KVA J EXIST. LANDLOARD i SWITCHBOARD ---- --- � EXISTING / MODIFIED ELECTRICAL EXTEND EXIST. 4 #6, CU, 4-#3/0, CU, 1-#10, CU, GRND, 1-#6, CU, GRND, IN 1" C. IN 2" C. TO NEW PANEL LOCATION 00 POWER RISER DIAGRAM 1.50 27 ® 28 1.00 3 20 EXIST. SF -1 7 SODA DISPENSER/ ICE BIN (OSCI) 1 COKE CO. FIELD VERIFY EQUIP. BEFORE MAKING ANY CUTS IN THE COUNTER TOP. FITS CUT OUT MEASURING 23-1/4"x23-1/4" CONTACT SANDY MANUEL(813)973-3465 TO COORD. DELIV. SPACE 29 ® 30 1.00 (1) I TIME CLOCK /SHUNT TRIP RELAY 20 1 0.20 31 ® 32 1.00 v v (5) W EXIST. WATER HEATER (#40) 30 2 2.25 33 ® 34 SPACE 10 MENU BOARD (BBC1) 8 VARIES SEE PLAN CUSTOM FABRICATED LCD PANELS \l, v JJ, 2.25 35 0 36 0.10 1 20 EXIST. HOOD & ANSUL PANELS I (5)(1) (4) L LIGHTS MENU BOARDS (#10) (T/C) 20 1 0.75 37 ® 38 0.20 EXIST. ROOF RECEPT. R 4, 20 COMBI OVEN (OSCI) 1 33-1/4" W 30-3/8" D 30-3/4" H RATIONAL MODEL #A619106.12.202 30.8 AMPS 208/3P 11.1 KW. 1/2" COLD WATER AND 2" DRAIN LINE STEAM TEMPERATURE RESISTANT DRAIN. MENU BOARDS (#10) (T/C) 0.50 39 ® 40 1.20 LIGHTS SIGN (T/C) L (4) i v ,, MENU BOARDS (#10) (T/C) 0.75 41 ■ 42 1.20 v .,, v SIGN (T/C) v TOTAL 13.45 15.25 13.70 8.83 6.58 8.35 TOTAL 26 EXH. HOOD (OSCI) 1 " 24 H EXISTING TO REMAIN. W/LIGHT FIXTURES. LENGTH & WIDTH VARY, SEE PLAN. LEGEND OA OB C SCALE: N.T.S. RISER DIAG. NOTES: L LIGHTING 22.28 21.83 22.05 TOTAL CONNECTED KVA R RECEPTACLE 186 182 184 TOTAL CONNECTED AMPS ANSUL SYSTEM TANKS AND CONTROL PANEL 1 "ANSUL" PRE -ENG. LIQUID CHEMICAL FIRE SUPPRESSION SYS. W/FIXED NOZZELS. SYS. TO BE UL CLASSIFIED AND INSTALLED PER NFPA #96 REQ. SYSTEM SHALL BE CAPABLE OF AUTOMATIC AND MECH. OPERATION W/AUTO SOLINOID GAS VALVE SHUT DOWN. ASSEMBLY, TESTING AND CERTIFICATION BY GEN. CONTR. INSTALL SYSTEM AS CLOSE TO CEILING AS POSSIBLE. MIN HGT. TO BOTT. OF UNIT TO BE 6'-6` AFF. NOTE: NOZZELS AND PIPING IN PUBLIC VIEW SHALL BE CHROME FINISHED. ELEC: FOR EMERGENCY SHUT OFF, CONNECT CONTROL PANEL TO SOLINOID FOR SHUT DOWN OF GAS SUPPLY UPON ACTIVATION. PLUMB:CONNECT ANSUL TANKS TO HOOD W/ RED PAINTED PIPE. INSTALL GAS SOLINOID VALVE SIZED PER PIPE SIZE. K KITCHEN EQUIPMENT TAB THESE BREAKERS IN "ON" POSITION. 1 COORDINATE WITH LANDLORD AND VERIFY EXISTING DISC. SWITCH, METER, 75KVA 3 RELOCATE AND REUSE EXISTING PANEL "A" IN COMPLIANCE WITH THE KEY NOTE #19, XFRMR, FEEDERS AND CONDUITS ARE IN COMPLIANCE WITH RISER DIAGRAM AND O RISER DIAGRAM AND PANEL SCHEDULE. ALL BREAKERS IN ALL PANELS SHALL BE N.E.0 APPLICABLE CODE. IF YES USE THEM. IF NOT UPGRADE THEM PER RISER BOLTED TYPE. DIAGRAM AND LL'S DESIGN CRITERIA. 0 FURNISH ANDINSTALL NEW SUBPANEL "B" IN COMPLIANCE WITH THE KEY NOTE #19, O VERIFY EXISTING AND INSTALL NEW GROUNDING SYSTEM IN COMPLIANCE WITH RISER DIAGRAM AND PANEL SCHEDULE. ALL BREAKERS IN ALL PANELS SHALL BE RISER DIAGRAM AND N.E.C. STD. #250, REQUIREMENTS. BOLTED TYPE. I MISCELLANEOUS (1) PROVIDE (2) ROUTE LOCK AT THIS CIRCUIT WITH ISO. GROUND CONDUCTOR. M MOTOR/FAN (3) PROVIDE THIS BREAKER WITH SHUNT TRIP DEVICE. T TRANSFORMER/PANEL/ATS (4) ROUTE THESE LIGHT CIRCUITS THROUGH T/C. W WATER HEATER LOADS. (5) USE NO (6) REFER EXISTING BREAKERS CHANGE IS REQUIRED. TO PANEL "B" SCHEDULE AND WIRING FOR EXISTING FOR THIS LOAD DETAILS. 29 ICE MAKER (OSCI) 1 CUBER: 30" W 24.50" D 2.50" H MANITOWOC MODEL #QY 0605W 208-230/60/1, AIR COOLED, 9.2 AMPS, 1 HP 9,000 BTU/HR (AVERAGE) ALLOW 6" AIR CLEARANCE @ BACK OF UNIT. ELEC.: SIMPLEX @ 80" A.F.F. (3 WIRE WITH NEUTRAL FOR 115V) PROVIDE 6'CORD AND PLUG TO UNIT. PROVIDE 3/4" INDIRECT WASTE DRAINS FROM BIN & CUBER. 3/8" O.D. CONDENSATE AND 1/2" INDERECT WASTE FROM CONDENSER TO FLOOR NEW SUBPANEL ti ii LOAD ANALYSIS 1 BIN: 34" D 44" H MANITOWOC MODEL #S-570 ON 6"LEGS DRAIN. MAINFOLD AS REQUIRED. MCB: MLO: N/A A.I.C.: 10,000 AMP 60 AMP VOLTS: 120/208 V WITH EQUIPMENT PHASE: 3, S/N WIRE: GROUND BUSSES 4 BLDG: RUBY THAI KITCHEN MTD: RECESS LOAD VOLT CONNECTED (KVA) FACTOR DEMAND (KVA) 39 SANDWICH TOP REFRIGERATOR (OSCI) 1 60" W 34-1/8" D 40-3/8" H TRUE MODEL #TSSU-60-24M-B-ST 115/60/1, 7.8 AMPS, 1/3 HP 5-15P NEMA CONFIGURATION LIGHTING 120 6.15 125% 7.69 CONV. OUTLETS 120 3.80 100% 3.80 39a SANDWICH TOP REFRIGERATOR (OSCI) 1 48-3/8" W 34-1/8"D 40-3/8" H TRUE MODEL #TSSU 48 -18M -B 115/60/1, 8.6 AMPS, 1/3 HP 5-15P NEMA CONFIGURATION BRKR KVA PH LOAD CIR PHASE CIR KVA PH LOAD BRKR DESCRIPTION OF LOAD AMP P OA 0B OC NO A B C NO OA 0B OC P AMP DESCRIPTION OF LOAD MISC. 120 0.30 100% 0.30 K U.C. REFRIG. DISPLAY (#50) 20 1 0.58 1 ® 2 1.00 1 20 BAG -N -BOX SODA RACK (#6) K KITCHEN EQUIP. 120/208 45.41 65% 29.52 SANDWICH TOP REFRIG. (#39a) 0.90 3 0 4 0.98 WORKTOP COOLER (#41.1) 40 UNDERCOUNTER WATER HEATER (CSCI) 1 32-1/4" H 26-1/2" DIA EXISTING TO REMAIN STATE MODEL #PATRIOT PCE 50 20LSA 50 GAL, 4.5 KW, 208V, 1PH SANDWICH TOP REFRIG. (#39) 1.00 5 ® 6 0.63 2 DOOR REACH -IN COOLER (#48) WATER HEATER 208 4.50 65% 2.93 v SODA DISPENSER (#7) 1.00 7 ® 8 0.50 RECEPT. R R RECEPT. 0.50 9 ® 10 1.00 RECEPT. 208 6.00 125% 7.50 41 WORKTOP FREEZER (OSCI) 1 48-3/8" W 39-1/2" H TRUE MODEL #TWT -48F 115/60/1, 6.1 AMPS, 1/2 HP 5-15P NEMA CONFIGURATION K WORKTOP FREEZER (#41) 0.71 11 ® 12 1.00v ,✓ RECEPT.MOTOR v v REFRIG. COLD PAN (#3.1) v v 0.47 13 ■ 14 SPACE OTHERS --- _- 100% SPACE 15 le 16 TOTAL 66.16 51.74 41.1 WORKTOP COOLER (OSCI) 1 72-3/8„ W 31-1/8" D 39-1/2" H TRUE MODEL #TWT -72 115/60/1, 8.5 AMPS, 1/3 HP 5-15P NEMA CONFIGURATION v 17 ® 18 \ 120/208, 30 POWER SUPPLY CALCULATIONS: TOTAL 2.05 1.40 1.71 1.50 1.98 1.63 TOTAL 1. TOTAL DEMAND LOADS = 51.74 KVA 2. DEMAND CURRENT/0= 144 AMPS @ 120/208V,3Q 4. EXISTING PANEL "A" = 200 AMP, MCB, 120/208V, 30, 4W. 3. EXISTING POWER SUPPLY = 200 AMPS, 120/208V, 30, 4W. LEGEND OA OB OC 47 3 DOOR COOLER (OSCI)115/60/1, 1 78-1/8" W 29-1/2" D 83-3/8" H TRUE MODEL #T-72 9.6 AMPS, 1/2 HP 5-15P NEMA CONFIGURATION R RECEPTACLE 3.55 3.38 3.34 TOTAL CONNECTED KVA K KITCHEN EQUIPMENT 30 29 28 TOTAL CONNECTED AMPS 48 2 DOOR COOLER54-1/8" (OSCI) 1 W 294/2"D 83-3/8" H TRUE MODEL #T-49 115/60/1, 5.4 AMPS, 1/2 HP 5-15P NEMA CONFIGURATION A PANEL A-31 TIME CLOCK "TC" 365 DAYS ASTRONOMICAL PROGRAMMABLE 50 UNDERCOUNTER REFRIGERATED DISPLAY (OSCI) 1 48-3/8"W 30-1/8 D 29-3/4"H TRUE MODEL #TUC -48G 115/60/1,1/5 HP, 5 AMPS 5-15P NEMA CONFIGURATION 51 ELECTRICAL PANEL (CSCI) 2 ONE EXISTING RELOCATED AND ONE NEW b 1 H -.41141 646, 0 3350, ELECTRICALLY HELD CONTACTOR (TYP.) TIE TO A-31 N • a i , I CONTACT FROM FIRE DETECTION SYSTEM. XM040-V02120 VAC COIL, NEMA RELAY SQ."D" CLASS 8501 TYPENI i - 1 CONTACT LOCATED IN MANUAL OVERRIDE SWITCH "TR"A-12 1 ENCLOSURE CLASS - 9991-UE7. iANSUL O 1 SYSTEM CONTROL HEAD. -mai A-14 ® -4f if., A-40 ® _ _-ONle 1 _ ��'�0 -A-39 .- - TO LIGHTING O -IAF -O A-41 ® o► j LPARE SHUNT TRIP BREAKER J GAS SUPPLY SOLENOID VALVE A-42 ® I I - USED FOR UNDER HOOD COOKING EQUIPMENT SHUNT T`IP RELAY CONT`OL SPARE "...CS I DP.-- INTERIOR LIGHTING CONTROLS ® THE TIME CLOCK SHALL PROVIDE 365 DAYS, ADVANCE HOLIDAY, ASTRONOMICAL PROGRAMMABLE SHUT OFF SWITCH AND 0-2 HOURS MAXIMUM OVERRIDE SWITCH ® THE TIME CLOCK CAN BE INTERMATIC ET 7000 SERIES. ® THE TIME CLOCK SHALL HAVE BATTERY BACKUP 78 HOURS MIN. TIMER CONTROL FOR SIGNS AND LIGHTS NO SCALE (1) SEQUENCE OF OPERATION: UPON ACTIVATION OF THE ANSUL SYSTEM, AND/OR FIRE DETECTION SYSTEM. ALL EQUIPMENT UNDER HOOD, RTU -1 UNIT FAN, MAKEUP AIR FAN, AND GAS SUPPLY SOLENOID VALVE SHALL AUTOMATICALLY SHUT DOWN. EXHAUST FANS SHALL BE LOCKED IN "ON" POSITION. RECEIVED CITY OF TUKWILA SEPARATE DEC08 2016 PERMIT AND APPROVAL -PERMIT CENTER f REQUIRED SCALE: N.T.S. DATE: 11-4-16 JOB NO: 1670 DRAWN: CHECKED: J=7 AOn2! WESTFIELD SOUTHCENTER REVISIONS Q a J 4410 W. MELROSE AVENUE TAMPA, FLORIDA 33629 TEL. 813.333.2717 FAX. 813.289.3332 SEAL VAVITP 66: KAY $1A11 61§ WNESHIXti PANEL SCHEDULES, RISER DIAGRAM AND DETAILS SHEET NUMBER E2.0 ELECTRICAL SPECIFICATIONS AND INSTRUCTIONS FOR INSTALLATION WORK 1.0 GENERAL 1.1 BIDDERS QUALIFICATIONS AND INSTRUCTIONS: 1.1.1 QUALIFICATIONS: THE BIDDERS SHALL BE QUALIFIED, EXPERIENCED, AND LICENSED ELECTRICAL CONTRACTORS. THEY MUST BE FAMILIAR WITH ALL FEDERAL, STATE, AND LOCAL LAWS, ORDINANCES, RULES, AND REGULATIONS THAT MAY, IN ANY MANNER, AFFECT THE TASK. 1.1.2 BIDDING INSTRUCTIONS: BEFORE SUBMITTING THE BID, THE BIDDERS MUST REVIEW THE TENANT INFORMATION AND CRITERIA MANUAL, SPECIFICATIONS, PLANS, DRAWINGS, AND ALL OTHER CONDITIONS AND REQUIREMENTS THAT MAY, IN ANY MANNER AFFECT THE WORK UNDER CONTRACT. THEY MUST VISIT THE SITE OF THE PROPOSED PROJECT TO FAMILIARIZE THEMSELVES WITH THE LOCAL CONDITIONS, FIRE RATING REQUIREMENTS, AND THE NATURE OF THE PROJECT. THE PRICING SHALL BE BASED ON THESE SPECIFICATIONS AND THE MATERIALS SHOWN ON THE DRAWINGS. SUBMISSION OF THE BIDS SHALL BE CONSIDERED AS THE EVIDENCE THAT THE BIDDER IS FAMILIARIZED TO ALL THE FACETS OF THE SPECIFIED PROJECT. CONTRACTOR SHALL USE APPLICABLE SECTIONS OF THIS SPEC. 1.1.3 EXCEPTIONS: ANY EXCEPTIONS, OMISSIONS, DISCREPANCIES, AND DOUBTS REGARDING PLANS, DRAWINGS, AND SPECIFICATIONS, IF ANY, SHALL BE COMMUNICATED PROMPTLY IN WRITING TO THE ARCHITECT OR TO THE ENGINEER FOR THEIR REVIEW AND RESPONSE BACK BEFORE THE BID SUBMISSION DATE. NO ORAL COMMUNICATION REGARDING THE EXCEPTIONS OR CHANGES SHALL BE ACCEPTED. BIDDERS SHALL BE NOTIFIED OF ANY CHANGES, IF MADE, DUE TO THE ACCEPTANCE OF EXCEPTIONS BEFORE THE BID SUBMITTAL DATE. 1.1.4 MATERIAL TAKE OFF: ALL MATERIAL TAKE OFFS, OTHER THAN THE EXISTING DEVICES, SHALL BE MADE USING THE LIGHT & POWER WIRING AND CONDUIT DRAWINGS AND THEIR ASSOCIATED REFERENCES INCLUDING THE SPECIFICATIONS OF THIS PROJECT ON THIS DRAWING. ALL LIGHTING MATERIALS INCLUDING TRANSFORMER, PANELS, FIXTURES, SWITCHES, RECEPTACLES, WIRES AND RACEWAYS, ETC. SHALL BE PURCHASED BY THE CONTRACTORS PER SECTION NO. 2, UNLESS NOTED OTHERWISE. 1.1.5 BID PRICE: THE BID PRICE SHALL INCLUDE LABOR AND MATERIAL COSTS, NECESSARY INSURANCE COSTS AND PERMITS FEES AS REQUIRED TO INSTALL THE COMPLETE ELECTRICAL SYSTEM IN COMPLIANCE WITH THE DESIGN REQUIREMENTS OF THIS PROJECT. 1.1.6 SUCCESSFUL BIDDER: THE SUCCESSFUL BIDDER WILL BE REFERENCED AS THE CONTRACTOR FROM THIS POINT ONWARDS THROUGHOUT THE REST OF THE SPECIFICATION. 1.2 THE ELECTRICAL CONTRACTOR REQUIREMENTS AND INSTRUCTIONS: 1.2.1 THE CONTRACTOR SHALL USE EXPERIENCED AND SKILLED PERSONS TO PERFORM ALL THE ELECTRICAL INSTALLATION WORK UNDER THE CONSTANT SUPERVISION OF LICENSED ELECTRICIANS AND/OR LICENSED JOURNEYMAN ELECTRICIANS. 1.2.2 THE CONTRACTOR SHALL BE RESPONSIBLE FOR OBTAINING ALL REQUIRED PERMITS, PAYING ALL FEES, AND PROVIDING ALL NECESSARY INSPECTIONS INCIDENTAL TO THE ELECTRICAL PORTION OF THE WORK. 1.2.3 THE CONTRACTOR SHALL BE RESPONSIBLE FOR CARRYING NECESSARY INSURANCE AS REQUIRED BY LAW TO PROTECT EMPLOYEES, OTHER PERSONS, EQUIPMENT, AND MATERIAL. 1.2.4 THE INSTALLATION WORK SHALL COMPLY WITH ALL APPLICABLE STATE, COUNTY, AND LOCAL BUILDING CODES. APPLICABLE CODES, AS A MINIMUM, WILL INCLUDE THE LATEST EDITION OF THE FOLLOWING. THESE WILL BE CONSIDERED PART OF THE SPECIFICATION OF THIS PROJECT. A) BUILDING CODE OF THE APPLICABLE CITY AND COUNTY. B) NATIONAL ELECTRIC CODE NFPA 70, 2008 C) LIFE SAFETY CODE NFPA 101, 2006 D) S.B.C.C.I. LATEST EDITION. 1.2.5 IN CASE OF SUBSTITUTIONS THE CONTRACTOR SHALL PROVIDE A WRITTEN REQUEST TO THE ARCHITECT FOR HIS REVIEW . THE CONTRACTOR SHALL IDENTIFY CLEARLY THE DIFFERENCE BETWEEN THE SPECIFIED ITEMS AND THE SUBSTITUTE ITEMS, INCLUDING THE ECONOMIC IMPACT ON THE PROJECT. THE SUBSTITUTE ITEM SHALL NOT BE ORDERED OR USED UNLESS APPROVED BY THE ARCHITECT AND/OR BY THE OWNER IN WRITING. 1.2.6 THE CONTRACTOR SHALL SUBMIT FIVE SETS OF SHOP DRAWINGS FOR SPECIFIED PRODUCTS AT ONE TIME WITHIN THIRTY (30) DAYS FROM THE OFFICIAL NOTICE TO PROCEED. SHOP DRAWING SUBMITTAL SHALL BE MADE FOR THE FOLLOWING MATERIALS AND SYSTEMS: A. LIGHTING FIXTURES, DIMMERS, LAMPS, AND SAFETY SWITCHES. B. TRANSFORMERS, SWITCH BOARDS, DISTRIBUTION PANELS , DISCONNECTS, AND WIREWAYS IF PURCHASED NEW. C. METER CENTERS, CIRCUIT BREAKERS, FUSES, MOTOR STARTERS IF PURCHASED FOR THIS PROJECT. D. TIME CLOCK AND OTHER DEVICES. E) SCHEMATIC DIAGRAMS FOR THE ABOVE ITEMS. 1.2.7 THE CONTRACTOR SHALL PROVIDE FOLLOWING DOCUMENTS BEFORE THE CLOSING OF THE PROJECT AND PRIOR TO THE FINAL PAYMENT: A. ONE YEAR WRITTEN WARRANTY FOR ANY DEFECT IN WORKMANSHIP, MATERIAL, AND EQUIPMENT. B. TWO SETS OF MANUFACTURER'S OPERATIONAL AND MAINTENANCE MANUALS IF APPLICABLE. C. MANUFACTURER'S WARRANTIES AND WARRANTY CERTIFICATES. D. TWO SETS OF REPRODUCIBLE OR RED MARKED UP PRINTS OF "AS -BUILT" DRAWINGS, ONE FOR THE ARCHITECT AND ONE FOR THE OWNER OF THE PROJECT. 1.2.8 THE CONTRACTOR SHALL BE RESPONSIBLE TO PROVIDE THE NECESSARY TEMPORARY ELECTRICAL POWER, AT HIS EXPENSE, AS REQUIRED BY HIS TRADE AND BY THE GENERAL CONTRACTOR. 1.2.9 THE CONTRACTOR SHALL MAKE SURE ON A DAILY BASIS THAT ALL UNNECESSARY MATERIAL AND TRASH CONTRIBUTED BY HIS TRADE ARE REMOVED. 1.2.10 THE CONTRACTOR SHALL CONCEALED ALL THE CONDUIT IN THE FINISHED AREAS. 2.0 PRODUCTS: 2.1 GENERAL: THE ELECTRICAL CONTRACTOR SHALL PURCHASE AND USE ALL "NEW" MATERIAL AS SPECIFIED AND SHOWN ON THE ELECTRICAL PLAN OF THIS PROJECT. ALL THE MATERIAL SHALL BE FREE FROM DEFECTS AND SHALL CARRY "UL" LABEL. 2.2 CONDUCTORS: ALL INSULATED CONDUCTORS SHALL BE UNCOATED COPPER OF 98% CONDUCTIVITY, 600 VOLT AC, DUAL RATED, TYPE THHN/THWN AS NECESSARY TO MEET THE DESIGN REQUIREMENTS AND THE APPLICABLE CODES. THW (FOR # 4 AWG AND LARGER) AND THERMO PLASTIC WIRES RATED FOR 75 DEGREES CENTIGRADE OPERATIONS IN WET AND DRY LOCATIONS AND 90 DEGREES CENTIGRADE WITHIN ELECTRIC DISCHARGE LIGHTING EQUIPMENT MAY BE USED. CONDUCTORS NUMBER # 10 AWG AND LOWER SHALL BE SOLID COPPER AND #8 AWG AND ABOVE SHALL BE STRANDED COPPER. THE MINIMUM SIZE OF WIRE SHALL BE # 12 AWG FOR 20 AMP BREAKER, # 10 AWG FOR 30 AMP BREAKER, # 8 AWG FOR 40 AMP BREAKER. 2.3 CABLE: SIGNAL CABLES, IF USED, SHALL BE COPPER AND SHALL MEET ALL UL AND N.E.C. CODE REQUIREMENTS. METAL CLAD (TYPE MC), ARMORED (TYPE AC) AND NON- METALLIC (NM) CABLES SHALL NOT BE USED. ALL CABLE ASSEMBLIES SHALL CONTAIN COPPER GROUND CONDUCTOR. 2.4 CONDUITS: THE CONDUITS SHALL BE ELECTRICAL METALLIC TUBING (EMT) AND HOT DIPPED GALVANIZED STANDARD STEEL AS MANUFACTURED BY WHEATLAND TUBE COMPANY OR EQUIVALENT. 2.5 OUTLET BOXES AND FITTINGS: OUTLET BOXES, FITTING CLAMPS AND HANGERS ETC. SHALL BE GALVANIZED STEEL, RUST RESISTANT AND COMPATIBLE WITH THE RACEWAY. OUTLET BOXES FOR FIXTURES, SWITCHES, AND RECEPTACLES SHALL HAVE SMOOTH ROUND EDGES AND SHALL BE WITH COVER PLATES. BOXES SHALL BE "STEEL CITY" OR EQUIVALENT. FITTINGS FOR EMT CONDUITS SHALL BE COMPRESSION TYPE. NO SET SCREW WILL BE USED. UNUSED HOLES SHALL BE COVERED WITH APPROVED INSERT CAPS. 2.6 SWITCHES AND DIMMERS: SWITCHES AND DIMMERS SHALL BE TOTALLY ENCLOSED, RATED AT 120/277 VOLTS AC, 20 AMPS, 2000 WATTS WITH GRAY TOGGLE AND DEVICE PLATE. THESE SHALL BE QUIET OPERATION, COMMERCIAL GRADE AS MANUFACTURED BY LEVITON, LUTRON OR EQUIVALENT. PLATES SHALL MATCH THE SWITCHES. FURNISH IN GANGS AS NECESSARY. 2.7 RECEPTACLES: RECEPTACLE SHALL BE COMMERCIAL GRADE, 125 VOLTS AC, AND 20 AMPERE RATING WITH GROUNDED POLE AND TWO CIRCUIT OPTION, AS MANUFACTURED BY LEVITON OR EQUIVALENT. PLATES SHALL MATCH THE RECEPTACLES. FURNISH IN GANGS AS NECESSARY. 2.8 DEVICE PLATES: PROVIDE DEVICE PLATE FOR EACH AND EVERY OUTLET BOX. FURNISH IN GANGS AS NECESSARY. PLATES AND SCREWS SHALL BE GRAY UNLESS THE OWNER PREFERS SOME OTHER COLOR, AND SHALL BE OF THE SAME MANUFACTURER AS OF THE DEVICES. 2.9 BALLASTS: BALLASTS FOR FLUORESCENT FIXTURES SHALL BE RAPID START, SYLVANIA ELECTRONIC ENERGY SAVING, HIGH POWER FACTOR AND SHALL BE CLASS "P," CBM, TITLE 24 CERTIFIED WITH INTERNAL THERMAL PROTECTOR WITH AUTOMATIC RESET AND CLASS "A" SOUND RATING NOISE LEVELS LESS THAN 30 dB MAXIMUM. BALLASTS SHALL BE MANUFACTURED BY SYLVANIA AS SHOWN ON THE LIGHTING SCHEDULE OR EQUAL EQUAL AND SHALL SHALL BE GUARANTEED AT LEAST FOR FIVE (5) YEARS OF OPERATION AFTER THE ACCEPTANCE. THE BALLAST MODEL NUMBER SHALL BE "2 OR 4 LAMP PSX-SYL Xtreme AS REQUIRED". 2.10 LAMPS: LAMPS SHALL BE MANUFACTURED BY SYLVANIA MODEL # SYL "F028/841XP/SS/ECO OR EQUIVALENT. ALL LAMPS SHALL BE GUARANTEED FOR AT- LEAST 4 YEARS OF OPERATION AFTER THE ACCEPTANCE. 2.11 LIGHTING DEVICES: ALL LIGHTING FIXTURES, EMERGENCY & EXIT LIGHTS SHALL BE AS LISTED ON THE LIGHT FIXTURE SCHEDULE; HOWEVER BEFORE PURCHASING ANY LIGHT FIXTURES, SUBMIT FIXTURE. CUT SHEETS FOR THE ARCHITECT AND THE OWNER'S APPROVAL. 2.12 TIME CLOCK OR TIME SWITCH: TIME CLOCK SHALL BE ELECTRO -MECHANICAL 24 HOURS SEVEN DAYS TYPE WITH RESERVE POWER AND CONTACTS RATED 40 A. 4 PST AND N.E.M.A. TYPE 1 OR 3R ENCLOSURE. IT SHALL BE SELF POWERED BY A SELF STARTING SYNCHRONOUS MOTOR WITH MINIMUM 16 HR SPRING DRIVEN RESERVE POWER AND A DAY OMITTING DEVICE. TIME CLOCK SHALL BE PARAGON 7007-0, TORK "W" SERIES, OR APPROVED EQUAL. 2.13 GUARANTEE: ALL ELECTRICAL EQUIPMENT, MATERIAL AND WORKMANSHIP SHALL BE GUARANTEED FOR A PERIOD OF ONE (1) YEAR FROM THE DATE OF ACCEPTANCE. 3.0 INSTALLATION INSTRUCTIONS: 3.1 GENERAL: 3.2 3.3 3.4 3.5 THE PLAN LOCATION OF LIGHTING FIXTURES, JUNCTION BOXES, CONVENIENCE OUTLETS, AND PANEL BOARDS ARE APPROXIMATE UNLESS DIMENSIONED AND ARE TO BE ADJUSTED BY THE CONTRACTOR AS REQUIRED IN THE AREAS WHERE CEILING GRID AND OTHER OBSTRUCTIONS DETERMINE FIXTURE LOCATIONS. THE CONTRACTOR SHALL COORDINATE WITH OTHER ARCHITECTURAL, MECHANICAL AND OTHER SYSTEMS TO AVOID INTERFERENCE. ALL CUTTING AND CONSEQUENT REPAIRS IN CONJUNCTION WITH THE WORK SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR. BEAMS OR OTHER STRUCTURAL COMPONENT SHALL NOT BE CUT WITHOUT THE KNOWLEDGE AND WRITTEN CONSENT OF THE ARCHITECT. THE CONTRACTOR SHALL PROVIDE ALL NECESSARY MATERIALS, LABOR, TRANSPORTATION, RIGGING & HOISTING, TOOLS, AND STORAGE, ETC. FOR ALL WORK INDICATED AND REQUIRED FOR COMPLETE INSTALLATION. THE ELECTRICAL WORK SHALL BE EXECUTED IN ACCORDANCE WITH ALL APPLICABLE CODES AND SHALL INCLUDE COMPLETE TESTING OF ALL EQUIPMENT AND WIRING. WORKMANSHIP SHALL BE THE HIGHEST QUALITY AS ESTABLISHED BY TRADE STANDARD. THE CONTRACTOR SHALL BE RESPONSIBLE FOR OBTAINING NECESSARY PERMITS AND COMMUNICATIONS WITH THE LOCAL BUILDING DEPARTMENT AND INSPECTION PERSONNEL TO REVIEW CONTRACT DOCUMENTS PRIOR TO INSTALLATION. OWNER WILL NOT BE HELD RESPONSIBLE FOR FIELD CHANGES THAT ARISE FROM CONTRACTOR'S ERROR OR OMISSION OF MATERIALS OR WORKMANSHIP IN WORK PERFORMANCE. 3.6 THE CONTRAC-OR SHALL BE RESPONSIBLE FOR VERIFICATION OF ALL UTILITIES PLACEMENT, AS IDENTIFIED ON THE RISER DIAGRAM, AND LOCATION OF THE ELECTRICAL SERVICE EQUIPMENT. THE CONTRACTOR SHALL PAY ALL NECESSARY CHARGES ASSOCIATED WITH INSTALLATION OF ALL UTILITIES TO THE POWER COMPANY PRIOR TO THE CONSTRUCTIOU. A LETTER SHALL BE PROVIDED FROM THE POWER COMPANY THAT ALL THE CHARGES HAVE BEEN PAID IN FULL. 3.7 NECESSARY AND OBVIOUSLY REQUIRED, ELECTRICAL ITEMS THAT ARE NOT SHOWN ON THE DRAWINGS, SHALL NOT RELIEVE THE CONTRACTOR OF HIS RESPONSIBILITIES TO INSTALL A COMPLETE AND SAFE ELECTRICAL SYSTEM. 3.8 THE ELECTRICAL CONTRACTOR SHALL FOLLOW THE SAME COLOR CODE IDENTIFICATION FOR EACH PHASE THROUGHOUTTHE SYSTEM FROM SERVICE SWITCH OR TRANSFORMER THROUGH ALL BRANCH CIRCUITS. 3.9 ALL SLAB OR ROOF PENETRATIONS SHALL BE MADE WITH APPROVED FIRE RATED SMOKE BARRIER FITTINGS. PROVIDE ACCESSORIES (?ITCH POCKETS, SLEEVES, ETC.) AS REQUIRED. 3.10 JUNCTION BO)ES FOR NEON SIGN LIGHTS, SWITCHES, LIGHTING FIXTURES, RECEPTACLES AND FOR PULLING WIRES SHALL BE AS APPROXIMATE AS SHOWN ON THE PLANS BUT EXACT LOCATIONS SHALL BE GOVERNED BY THE ARCHITECTURAL PLANS. 3.11 ALL OUTLET BOXES SHALL HAVE SQUARE CUT CORNERS. AIR SPACE GREATER THAN 1/8" AROUND OUTLET BOXES, AND ADJACENT DRSWALL WILL NOT BE PERMITTED. THE CONTRACTOR SHALL COORDINATE WITH DRYWALL INSTALLER PRIOR TO INSTALLATION. CAULK AROUND BOXES TO ELIMINATE STEEL OUTLET. 3.12 LIGHTING SWI1CHES AND CONVENIENCE RECEPTACLES SHALL BE FLUSH MOUNTED IN SECTIONAL SWITCH BOXES WITH MATCHING CO/ER PLATES UNLESS NOTED OTHERWISE. 3.13 THE MOUNTING ARRANGEMENT OF EACH FIXTURE WILL BE DETERMINED BY THE CONTRACTOR EXCEPT WHERE THE MANUFACTURER HAS GIVEN SPECIFIC MOUNTING INSTRUCTIONS. 3.14 THE CONTRACOR SHALL FURNISH AND INSTALL ALL LUMINARIES, DEVICES, AND EQUIPMENT AS SPECIFIED AND SHOWN ON THE PLAN DIAGRAMS. PROVIDE ALL CABLES, CONDUCTORS, CONDUITS, AND CONNECTIONS AS REQUIRED TO PROVIDE COMPLETE AND OPERATIONAL ELECTRICAL AND MECHANICAL SYSTEMS. ALL CONDUITS SHALL BE RUN CONCEALED IN FINISHED AREAS. 3.15 INDIVIDUAL BREAKERS WILL SUPPLY ELECTRICAL POWER TO INDIVIDUAL SIGN OR NEON LIGHT CIRCUITS. NEON TRANSFORMER, EQUIPMENT IS TO BE CONCEALED ABOVE ADJACENT COLUMN ENCLOSURE OR TO BE INSTALLED AS SHOWN ON AFCHITECTURAL DRAWINGS. 3.16 ALL JOINTS IN CONDUIT AND RACEWAY SHALL BE MADE TIGHT AND BENDS SHALL BE MADE OVER LONG RADIUS WHERE ENTERNG A CABINET AND JUNCTION BOX. THE CONTRACTOR SHALL SUPPORT ALL CONDUIT AND RACEWAYS SECURELY FROVI JOISTS AND/OR BEAMS (TIE WIRES ARE NOT ACCEPTABLE). THE CONTRACTOR SHALL VERIFY ALL RACEWAY SIZE; IN ACCORDANCE WITH THE N.E.C. CODE. NO CONDUIT SHALL CARRY MORE THAN THREE (3) CURRENT CARRYING CONDUCTORS. NOTE: ALL JOB CUT THREADS SHALL BE COATED WITH RUST RESISTANT ZINC CHROMATE FOR THIN WALL EMT. 3.17 LIGHTING CONDUITS SHALL BE SUPPORTED AT EVERY 8 FEET. 3.18 MOUNTING HEIGHT OF LIGHTING EQUIPMENT, UNLESS NOTED OTHERWISE ON ARCHITECTURAL PLANS SHALL BE APPROXIMATELY AS FOLLOWS: A. LIGHTING SWITCHES CENTERLINE 4 FEET ABOVE A.F.F B. CONVENIENCE OUTLETS CENTERLINE 1 FEET, 6 INCHES A.F.F C. LIGHTING 3c POWER PANELS TOP 6 FEET, 6 INCHES ABOVE A.F.F D. EMERGENCY LIGHT FIXTURES 9' ABOVE A.F.F TO BOTTOM OF THE UNIT. 3.19 ELECTRICAL RACEWAYS AND SHALL BE SIZED IN ACCORDANCE WITH NATIONAL ELECTRIC CODE (N.E.C.), ARTICLE 250. ALL BRANCH CIRCUITS SHALL HAVE A SEPARATE GREEN INSULATED GROUND WIRE IN EACH CONDUIT RUN. ISOLATED GROUND CONDUCTORS SHALL BE ROUTED TO THOSE CIRCUITS WHICH NEED ISOLATED GROUND SPECIALLY FOR COMPUTERS AND CASH REGISTERS. 3.20 THE CONTRACOR SHALL PROVIDE LIGHTNING PROTECTION VOLTAGE SURGE PROTECTOR FOR ALL SERVICE PHASE CONDUCTORS f0 GROUND (IF IT IS NOT ALREADY THERE IN CASE OF RENOVATIONS). DEVICE SHALL BE APT TE 400 OR APPROVED EQUIVALENT. 3.21 LUMINARIES SHALL BE AS SPECIFIED IN THE "LIGHTING FIXTURE SCHEDULE". ALL RECESSED AND LAY -IN FIXTURES SHALL BE SUPPORTED FROM THE FOUR CORNERS WITH SUPPORTS CAPABLE OF CARRYING TWICE THE WEIGHT OF THE FIXTURE. ALL SUPPORTS SHALL BE ATTACHED TO THE JOISTS AND/OR BEAMS. NO LIGHTING FIXTURE SHALL BE INSTALLED WI1HIN 2 FEET OF ANY SPRINKLER HEAD. 3.22 THE CONTRAC-OR SHALL INSTALL ALL TELEPHONE JACKS AND WIRING FROM THE MAIN TELEPHONE TERMINAL BOARD TO THE FINAL-ELEPHONEOUTLETS. WIRING SHALL BE INSTALLED IN A MINIMUM 1/2 INCH CONDUIT. 3.23 THE CONTRACOR SHALL COORDINATE WITH THE FIRE PROTECTION CONTRACTOR AND SHALL MAKE ALL NECESSARY CONNECTIONSBETWEEN DUCT SMOKE DETECTORS AND HVAC UNITS. 3.24 ALL JUNCTION BOXES SHALL BE ACCESSIBLE FROM BELOW. OTHERWISE, CONTRACTOR SHALL PROVIDE ACCESS PANEL AT ALL JUNCTION BOX LOCATIONS AND SMOKE DETECTORS. 3.25 IF NOT ALREADY EXISTING, THE CONTRACTOR SHALL FURNISH ALL THE NECESSARY DISCONNECT SWITCHES, RELAY BOXES, AND CONTROL BOXES AS REQUIRED AND RECOMMENDED BY THE HVAC MANUFACTURER FOR THE HVAC UNIT AND WATER HEATER. THE ELECTRICAL CONTRACTOR SHALL COORDINATE WITH THE MECHANICAL CONTRACTOR AND MAKE ALL NECESSARY CONNECTIONS TO MAKE THE HVAC SYSTEM FUNCTIONAL. 3.26 A PLASTIC COVERED TYPE WRITTEN IDENTIFICATION CARD FOR ALL MAIN AND BRANCH CIRCUITS INCLUDING SPARES SHALL BE POSTED AT THE INSIDE OF THE PANEL DOOR. 3.27 LOCK -ON DEVICES ON PANEL CIRCUIT BREAKERS FOR NIGHT, EXIT AND EMERGENCY LIGHTING CIRCUITS SHALL BE PROVIDED AND THE SHALL BE GIVEN TO THE OWNER. 3.28 LOW VOLTAGEWIRING LOCATED ABOVE THE CEILING SHALL BE PLENUM RATED OR INSTALLED IN METAL CONDUIT. 4.0 TRANSFORMER AND PANEL BOARD SPECIFICATIONS : THIS SECTION SHALL APPLY TO THE NEW TRANSFORMER, PANEL BOARDS, CIRCUIT BREAKERS, PANEL BOXES & TRIMS, DISCONNECT SNITCHES, AND FUSES. 4.1 PANEL BOARDS: PANEL BOARDS SHALL BE GENERAL PURPOSE N.E.M.A. TYPE 1 OR TYPE 3R ENCLOSURES SUITABLE FOR SPECIFIED INDOOR OR OUT DOOR LOCATIONS AND AND FLUSH OR SURFACE MOUNTING APPLICATIONS AS INDICATED ON THE PANEL SCHEDULE. PANEL BOARDS AND THE INTERNAL COMPONENTS SHALL BE RATED TO PERFORM THEIR FUNCTIONS CONTINUOUSLY AT 40°C AMBIENT AND 50% RELATIVE HUMIDITY. BUSSES, TERMINALS, AND LUGS SHALL BE RATED AND CAPABLE TO FUNCTION CONTINUOUSLY AT 75 DEGREES CENTIGRADE. PANEL BOARDS SHALL BE AS MANUFACTURED BY WESTINGHOUSE ELECTRIC CORP., GENERAL ELECTRIC, SQUARE 'D', CHALLENGER, OR APPROVED EQUAL. A NAMEPLATE LISTING PANEL NUMBER, TYPE, MANUFACTURER'S NAME, NUMBER OF PROTECTIVE AND SWITCHING DEVICES, VOLTAGE, CURRENT, PHASE AND AIC RATINGS SHALL BE PROVIDED. BRANCH CIRCUITS SHALL BE ARRANGED USING DOUBLE ROW CONSTRUCTION. ALL INTERIORS SHALL BE COMPLETELY FACTORY ASSEMBLED WITH SWITCHING AND PROTECTIVE DEVICES, WIRE CONNECTORS, ETC. ALL WIRE CONNECTORS, EXCEPT SCREW TERMINALS, SHALL BE OF THE ANTI -TURN SOLDERLESS TYPE AND ALL SHALL BE SUITABLE FOR COPPER WIRE OF THE SIZES INDICATED ON DRAWINGS OR IN THE PANEL SCHEDULES AND CONTINUOUSLY FUNCTIONING AT 75 DEGREE CENTIGRADE. ALL BREAKERS, SIZED AS SHOWN ON PANEL SCHEDULE, SHALL BE BOLT -ON BREAKERS. INTERIORS SHALL BE SO DESIGNED THAT SWITCHING AND PROTECTIVE DEVICES CAN BE REPLACED WITHOUT DISTURBING ADJACENT UNITS AND WITHOUT REMOVING THE MAIN BUS CONNECTORS AND SHALL BE SO DESIGNED THAT CIRCUITS MAY BE CHANGED WITHOUT MACHINING, DRILLING, OR TAPPING. BUS BARS FOR THE MAINS SHALL BE OF COPPER AND SIZED IN ACCORDANCE WITH UNDERWRITERS' LABORATORIES STANDARDS. UNLESS NOTED OTHERWISE, FULL SIZE NEUTRAL BARS SHALL BE INCLUDED. BUS BAR TAPS FOR PANELS WITH SINGLE POLE BRANCHES SHALL BE ARRANGED FOR SEQUENCE PHASING OF THE BRANCH CIRCUITDEVICES. THE SHORT CIRCUIT RATING OF THE ASSEMBLED PANEL BOARD SHALL BE IN ACCORDANCE WITH UL. INC. STANDARDS AND THEIR TEST VERIFICATION. PHASE BUSSING SHALL BE FULL HEIGHT WITHOUT REDUCTION. CROSS AND CENTER CONNECTORS SHALL BE COPPER. NEUTRAL AND GROUND BUSSING SHALL HAVE SUITABLE LUGS FOR OUTGOING FEEDERS REQUIRING A NEUTRAL AND GROUND CONNECTIONS. SPACES FOR FUTURE SWITCHING AND PROTECTIVE DEVICES ON LIGHTING AND APPLIANCE DISTRIBUTION PANELS SHALL BE BUSSED FOR THE MAXIMUM DEVICE THAT CAN BE FITTED INTO THEM. PROVIDE BLANK FILLER PLATES IN THE EMPTY SPACES. 4.2 CIRCUIT BREAKER: THE CIRCUIT BREAKERS ARE TO BE INDUSTRIAL MOLDED CASE BOLT ON TYPE, STANDARD THERMAL, MAGNETIC, WITH TRIP FREE MECHANISM, THREE POSITION HANDLES INDICATING "ON" "OFF" AND "TRIPPED" CONDITION. EACH POLE SHALL PROVIDE INVERSE TIME DELAY AND INSTANTANEOUS CIRCUIT PROTECTION. THE BREAKER RATING AND CONFIGURATION SHALL BE AS INDICATED ON THE PANEL BOARD SCHEDULE. ALL MULTI POLE BREAKERS SHALL HAVE AN INTERNAL COMMON TRIP. ALL BREAKER LUGS SHALL BE SUITABLE TO WITHSTAND 75 DEGREE CENTIGRADE WITHOUT MALFUNCTIONING. 4.3 PANEL TRIM: HINGED DOORS IN PANEL TRIMS SHALL COVER ALL SWITCHING DEVICE HANDLES AND SHALL CONFORM TO THE FOLLOWING REQUIREMENTS: 1. DOORS SHALL NOT UNCOVER ANY LIVE PARTS WHILE MAKING SWITCHING DEVICE HANDLES ACCESSIBLE. 2. DOORS SHALL HAVE FLUSH -TYPE CYLINDER LOCK AND CATCH, EXCEPT THAT DOORS OVER 48" IN HEIGHT SHALL HAVE AUXILIARY FASTENERS AT TOP AND BOTTOM OF DOOR IN ADDITION TO FLUSH -TYPE CYLINDER LOCK AND CATCH. DOOR HINGES SHALL BE CONCEALED. ALL LOCKS SHALL BE KEYED ALIKE. DIRECTORY FRAME AND CARD HAVING ATRANSPARENT COVER SHALL BE FURNISHED ON EACH DOOR. THE TRIMS SHALL BE FABRICATED FROM CODE GAUGE SHEET STEEL. ALL EXTERIOR AND INTERIOR STEEL SURFACES OF THE PANEL BOARDS SHALL BE PROPERLY CLEANED PRIMED AND PAINTED IN ACCORDANCE WITH THE MANUFACTURER'S STANDARD SPECIFICATIONS AND COLOR. TRIMS FOR FLUSH MOUNT PANELS SHALL OVERLAP THE BOX BY AT LEAST 3/4" ALL AROUND. SURFACE MOUNT PANELS TRIMS SHALL HAVE THE SAME WIDTH AND HEIGHT AS'7F THE BOX. TRIMS SHALL BE MOUNTABL,BY A SCREW DRIVER WITHOUT THE NEED FOR SPECIAL TOOLS. 4.4 PANEL BOXES: BOXES SHALL BE MADE FROM UNPAINTED GALVANIZED CODE GAUGE STEEL HAVING MULTIPLE KNOCKOUTS ON THE TOP AND THE BOTTOM EXCEPT WHERE NOTED OTHERWISE. BOXES SHALL BE OF SUFFICIENT SIZE TO PROVIDE A MINIMUM GUTTER SPACE OF 4" ON ALL SIDES. WHERE FEEDER CABLES SUPPLYING THE MAINS OF A PANEL ARE CARRIED THROUGH ITS BOX TO SUPPLY OTHER ELECTRICAL EQUIPMENT, THE BOX SHALL BE 50 SIZED AS TO INCLUDE THIS WIRING SPACE. THIS WIRING SPACE SHALL BE IN ADDITION TO THE MINIMUM GUTTER SPACE SPECIFIED ABOVE AND THE LIMITING WIDTH MAY BE INCREASED ACCORDINGLY. AT LEAST FOUR (4) INTERIOR MOUNTING STUDS SHALL BE PROVIDED. ALL UNUSED HOLES IN THE BOXES SHALL BE PLUGGED WITH APPROVED INSERT CAPS. BOXES SHALL BE "STEEL CITY" OR EQUAL. 4.5 DISCONNECT SWITCHES: THE CONTRACTOR SHALL INSTALL N.E.M.A. TYPE 1 DISC. SWITCHES FOR INDOOR AND N.E.M.A. TYPE 3R DISC. SWITCHES FOR OUT DOOR APPLICATIONS. ALL DISCONNECT SWITCHES FOR SERVICE CONDUCTOR ENTRANCES SHALL BE RATED AT LEAST 100K AIC. DISCONNECT SWITCHES FOR MOTOR CIRCUIT AND FIXED LOAD (SUCH AS HVAC EQUIPMENT, AND WATER HEATER ETC.) CIRCUITS SHALL BE FUSIBLE OR NON FUSIBLE AS SHOWN ON THE DRAWINGS OR REQUIRED BY THE MANUFACTURER. 4.6 FUSE: THE CONTRACTOR SHALL USE DUAL ELEMENT, TIME DELAY CURRENT LIMITING, 100,000 AMP AIC RATED, CLASS RK -1 FUSES WHEN PROTECTING PANEL BOARDS AND TRANSFORMERS AND 100,000 AMP AIC RATED CLASS RK -5 FUSES WHEN PROTECTING MOTORS UNLESS NOTED OTHERWISE OR REQUIRED DIFFERENTLY BY THE MANUFACTURER. ALL FUSES IN ANY DISC.. SW SHALL BE OF THE SAME MANUFACTURER AND SHALL BE MANUFACTURED BY BUSSMANN, GOULD SHAWMUT OR EQUIVALENT. bt(r� 33s SEPARATE PERMIT AND APPROVAL REQUIRED RECEIVED CITY OF TUKWILA DEC 08 2016 PERMIT CENTER DATE: 11-4-16 JOB NO: 1670 DRAWN: CHECKED: z w z U 1,11== AEI nu ELD SOUTHCENTER REVISIONS 4410 W. MELROSE AVENUE TAMPA, FLORIDA 33629 TEL. 813.333.2717 FAX. 813.289.3332 ELECTRICAL SPECIFICATIONS SHEET NUMBER E3.0 STUDOR MINI -VENT AIR ADMITTANCE VALVE STUDOR MINI -VENT AIR ADMITTANCE VALVE EXIST. WASTE LINE DOWN TO EXIST. GREASE INTERCEPTOR EX INS 1 V71-4.Afff re LINE ROOF EXIST. INSTALL NEW 2" VENT LINE EXIST. FCO EXIST. RELOC. EXIST. RELOC. STUDOR MINI -VENT AIR ADMITTANCE VALVE STUDOR MINI -VENT AIR ADMITTANCE VALVE STUDOR MINI -VENT AIR ADMITTANCE VALVE EXIST. FCO STUDOR MINI -VENT AIR ADMITTANCE VALVE WASTE PLAN SCALE: 1/4" = 1'-0" RELOCATE EXISTING STUDOR MINI -VENT AIR ADMITTANCE VALVE FOR EXISTING FLOOR SINK AS REQUIRED ISOMETRIC VIEW TILE, SLOPE 1/4"/FT. WATERPROOF MEMBRANE CAST IRON HALF GRATE DOME STRAINER CLAMP RING - CONC. FOR SINK SIZE AND TYPE, SEE PLUMBING FIXTURE SCHEDLLE AND SPEC. FLOOR SINK DETAIL SCALE: N.T.S. D EQUIPMENT REQUIREMENTS ITEM PLUMBING REQUIREMENTS SIZE HW SIZE WASTE SIZE VENT SIZE MANUFACTURER/ MODEL REMARKS COOKING EQUIPMENT STEAM TABLE 1/2" 1" AIR GAP SEE EQUIP. SCHED. SHEET A2.0 WASTE TO BE INDIRECTLY CONNECTED TO FLOOR SINK. 3.1 REFRIGERATED COLD PAN 3/4" AIR GAP SEE EQUIP. SCHED. SHEET A2.0 WASTE TO BE INDIRECTLY CONNECTED TO FLOOR SINK. NOODLE TABLE 1/2" 1" AIR GAP SEE EQUIP. SCHED. SHEET A2.0 WASTE TO BE INDIRECTLY CONNECTED TO FLOOR SINK. BAG IN BOX SODA RACK 1/2" SEE EQUIP. SCHED. SHEET A2.0 6" CHASE UNDERCOUNTER TO SODA MACHINE. PROVIDE WATTS SD -3, ASSE 1022 BACKFLOW PREVENTER. SODA DISPENSER 1" AIR GAP SEE EQUIP. SCHED. SHEET A2.0 WASTE TO BE INDIRECTLY CONNECTED TO FLOOR SINK. 6" CHASE UNDERCOUNTER TO SODA RACK. 15 CHINESE WOK 1/2" 1-1/2" AIR GAP SEE EQUIP. SCHED. SHEET A2.0 WASTE TO BE INDIRECTLY CONNECTED TO FLOOR SINK. 20 COMB! OVEN 1/2" 2" AIR GAP SEE EQUIP. SCHED. SHEET A2.0 WASTE TO BE INDIRECTLY CONNECTED TO FLOOR SINK. 29 FILTER SYSTEM, ICEMAKER 1/2" 3/4" AIR GAP SEE EQUIP. SCHED. SHEET A2.0 WASTE TO BE INDIRECTLY CONNECTED TO EXISTING FLOOR SINK. PROVIDE WATTS SD -3, ASSE 1022 BACKFLOW PREVENTER. 32 DROP-IN 3 COMPARTMENT SINK 1/2" 1/2" 140' F 2" 2" EXISTING RELOCATED WASTE TO BE INDIRECTLY CONNECTED TO EXISTING FLOOR SINK. STRAINER, FLUSH w/ FLOOR C1 1/2" TRAP PRIMER SLOPE FLOOR FINISH (-- 'TO DRAIN - 1/4"/FT. MIN, - ADJUSTABLE DRAIN HEAD DRAIN SUPPORT STRAP DEEP SEAL TRAP FLOOR DRAIN DETAIL SCALE: N.T.S. DRAIN BODY INSIDE CAULK PIPE 33 DROP-IN PREP SINK 1/2" 1/2" 1-1/2" AIR GAP EXISTING RELOCATED WASTE TO BE INDIRECTLY CONNECTED TO FLOOR SINK. 34 MOP SINK 1/2" 1/2" 3" 2" EXISTING RELOCATED WASTE TO BE DIRECTLY CONNECTED TO WASTE LINE 40 UNDERCOUNTER WATER HEATER 3/4" 3/4" OUT 1" AIR GAP EXISTING TO REMAIN STATE MODEL #PATRIOT PCE 50 2OLSA, 50 GAL, 4.5 KW WASTE TO BE INDIRECTLY CONNECTED TO FLOOR SINK. 46 DROP-IN HAND SINK 1/2" 1/2" 2" 2" EXISTING RELOCATED WASTE TO BE DIRECTLY CONNECTED TO WASTE LINE 46 DROP-IN HAND SINK 1/2" 1/2" 2" 2" EXISTING RELOCATED WASTE TO BE DIRECTLY CONNECTED TO WASTE LINE Cl TRAP PRIMER 1/2" ZURN Z-1022 SANI-GARD. CONNECT TO CW W/VALVE, EXTEND TPP TO FLOOR DRAIN AS REQUIRED. 1/2" CW INSTALL ONLY IF REQUIRED BY LOCAL CODE. C FLOOR DRAIN 3" 2" JOSAM 30000-S SERIES OR APPROVED EQUAL BOTTOM OUTLET WITH SUPER-FLO SQUARE NIKALOY STRAINER PROVIDE AND INSTALL TRAP PRIMER IF ONLY REQUIRED BY LOCAL CODE. WASTE TO BE. CONNECTED TO GREASE WASTE LINE. D FLOOR SINK 2" 2" JOSAM 49300 & 49310 SERIES. SUPER-FLO, 6" MEDIUM DEEP BODIES 8" SQUARE TOPS E SHOCK SUPPRESSORS AMTROL DIATROLS 537 OR APPROVED EQUAL INSTALLED AS RECOMMENDED BY P.D.I. EXIST. RELOC. EXISTING MAIN WATER LINE UP THROUGH FLOOR WATER PLAN SCALE: 1/4" = ISOMETRIC VIEW SYMBOL CODE MID COLD WATER PIPING HOT WATER PIPING FILTERED WATER PIPING -*-- INDIRECT WASTE PIPING SAN. WASTE PIPING EXIST. SAN. WASTE PIPING WASTE VENT PIPING SHUT OFF VALVE ih UNION T & P RELIEF VALVE VALVED WATER TAP CONNECT TO EXISTING F BACKFLOW PREVENTER WATTS #SD -3 ASSE 1022 FCO FLOOR CLEANOUT - ZURN NO. Z-1444, POLISHED BRONZE ACCESS COVER, DURA -COATED CAST IRON BODY. MATCH TO PIPE SIZE. NOTE: VERIFY FINAL PLUMBING REQUIREMENTS WITH FOOD SERVICE CUT SHEETS AND PLANS PRIOR TO THE START OF WORK TO AVOID ANY CONFLICTS. REFER TO ARCH. DWGS FOR MODEL INFORMATION. GENERAL PLUMBING SPECIFICATIONS: PLUMBING EQUIPMENT NOTES: 01) TIE-IN PLUMBING DRAIN LINES TO EXISTING WASTE LINE, �✓CONTRACTOR TO VERIFY EXACT LOCATION IN FIELD. 0CONNECTNEW VENT LINES TO EXISTING VENT UNE. CONTRACTOR TO VERIF" EXACT LOCATION IN FIELD. 0CONNECTWATER SUPPLY TO EXISTING SUPPLY LINE. CONTRACTOR TO VERIFY EXACT LOCATION IN FIELD. OINSTALL E" PIPE CHASE UNDER COUNTER FOR SODA LINES FROM BAG -IN BOX TO SODA DISPENSER. O5 PROVIDE BACKFLOW PREVENTER AS SHOWN OR WHEREVER BACK SIPHONAGE IS POSSIBLE. 6 FILTERED WATER TO BE SUPPLIED TO THE ICE MACHINE AND SODA SYF.UP LOCATIONS ONLY FLOW TO FIXTURE -1 z z z -J IMUM TO HORIZ 111111111111IUII11 IIJ111 J INSTALL ONLY IF REQUIRED BY LOCAL CODE AUTOMATIC TRAP PRIMER VALVE -MOUNT IN CW SUPPLY LINE OF FREQUENT USED FIXTURE NEAR FLOOR DRAIN(S) SUPPLIED i" COPPER TUBING - RUN UNDERFLOOR TO FLOOR DRAIN(S) FLOOR SLAB FLOOR DRAIN (SEE PLANS) 1111 III111J1IIII1111t A• TRAP PRIMER CONNECTION IN FLOOR DRAIN 111111111111111(1 1111111111 I I I I I ••D•11 • O . P .•. .6 fl • I>••• TYPICAL FOR ALL FLOOR DRAINS & FLOOR SINKS UNLESS NOTED OTHERWISE ON DRAWINGS TRAP PRIMER CONNECTION DETAIL SCALE: N.T.S. C1 1. ALL WORK UNDER THIS HEADING SHALL BE PERFORMED AND ALL MATERIALS AND EQUIPMENT SHALL BE INSTALLED IN STRICT COMPLIANCE WITH ALL RATINGS, CODES AND STANDARDS OR OTHER AUTHORITIES HAVING JURISDICTION. 2. ALL LICENSES, PERMITS, INSPECTIONS AND FEES REQUIRED FOR WORK UNDER THIS HEADING SHALL BE SECURED, PERFORMED AND PAID FOR BY THIS SUBCONTRACTOR AS A PART OF HIS CONTRACT. 3. ALL MATERIALS SHALL BE NEW, FREE FROM DEFECTS, AND FULLY EQUAL TO THE QUALITY SPECIFIED. WORK SHALL BE PERFORMED BY SKILLED MECHANICS AND WORKMANSHIP SHALL BE FIRST CLASS IN EVERY RESPECT. CONTRACTOR SHALL HAVE A COMPETENT SUPERINTENDENT (WHO IS EXPERIENCED IN THE WORK BEING INSTALLED UNDER THIS CONTRACT) IN CHARGE OF WORK AT ALL TIMES DURING CONSTRUCTION. 4. ALL PIPING SHALL HAVE THE MANUFACTURER'S NAME ROLLED INTO EACH LENGTH, OR SHALL OTHERWISE BE PROMINENTLY IDENTIFIED. AFTER CUTTING, ALL PIPE SHALL BE REAMED FULL BORE, AND ALL CUTTINGS, AND FOREIGN MATERIALS SHALL BE REMOVED BEFORE INSTALLATION. 5. ALL SANITARY WASTE AND VENT PIPING SHALL BE SERVICE WEIGHT CAST IRON, WITH FITTINGS OF THE SAME WEIGHT AS THE PIPE. THE CONTRACTOR SHALL ENSURE THAT THE INSTALLATION OF SUCH UTILITIES DOES NOT INTERFERE WITH THE MALL STRUCTURE OR THE OPERATIONS OF TENANTS BELOW. 6. ABOVE GRADE DOMESTIC WATER PIPE SHALL BE TYPE "L" SEAMLESS, HARD DRAWN COPPER TUBING AND TYPE "K" BELOW GRADE IN CONFORMANCE WITH ASTM B88-48. FITTINGS SHALL BE WROUGHT COPPER SUITABLE FOR 200 PSI. CONNECTIONS TO DISSIMILAR MATERIALS SHALL BE MADE WITH DIELECTRIC UNIONS. JOINTS SHALL BE 95-5 TIN ALTIMONY FOR 200 PSI. BELOW GROUND JOINTS SHALL BE BRAZED. 7, INSULATE DOMESTIC HOT WATER LINES WITH MINIMUM 1/2" FIBERGLASS INSULATION WITH AN ALL SERVICE VAPOR BARRIER JACKET WITH SEALED JOINTS. INSULATION AND JACKET SHALL HAVE A FLAME SPREAD RATING OF NOT OVER 25 W/O EVIDENCE OF CONTINUED PROGRESSIVE COMBUSTION AND A SMOKE DEVELOPED RATING OF NOT MORE THAN 50. 8. ALL FIXTURES SHALL HAVE INDIVIDUAL FIXTURE CONTROL VALVES WHICH SHALL BE CRANE, WATTS, NIBCO OR APPROVED EQUAL. VALVES OF EACH TYPE, SUCH AS GATE OR GLOBE, SHALL BE THE PRODUCTS OF ONE MANUFACTURER. VALVES SHALL BEAR THE NAME OR TRADEMARK OF THE MANUFACTURER AND THE WORKING PRESSURE CAST OR STAMPED ON THE VALVE BODY. MIN. 125 PSI. ALL VALVES SHALL BE ACCESSIBLE FOR EASE OF OPERATION. 9. PROVIDE DIELECTRIC FITTINGS BETWEEN PIPING OF DISSIMILAR METALS AND AT WATER HEATER CONNECTIONS. 10. PROVIDE 1/2" THICK FLEXIBLE UNICELLULAR FIRE RETARDANT INSULATION ON EXPOSED LAVATORY TRAP AND EXPOSED HOT AND COLD WATER SUPPLY AND ANY MISCELLANEOUS PIPING SUCH AS CONDENSATE PIPING. ALL JOINTS SHALL BE INSULATED AND SEALED WITH VAPOR BARRIER CEMENT. 11. ALL PIPING, PIPE HANGERS, CLAMPS, SUPPORTS, ETC. SHALL BE FASTENED TO JOISTS OR BEAMS. WHERE PIPING IS SUSPENDED FROM STEEL JOISTS, THE CONNECTION SHALL BE MADE AT THE TOP CHORD OF JOIST. PIPE SUPPORTS SHALL BE SPACED MO MORE THAN 10 FEET APART. NOTHING SHALL BE ATTACHED DIRECTLY TO THE DECK, CEILING SYSTEM OR DUCT WORK ABOVE. 12. HANGERS SHALL NOT PIERCE PIPING INSULATION VAPOR BARRIER. 13. IT IS THE CONTRACTOR'S RESPONSIBILITY TO REPAIR ANY DAMAGE DONE TO THE FIRE PROOFED STRUCTURAL STEEL SERVING THE FIRST FLOOR. 14. ALL HANGERS, RODS, BEAM CLAMPS ETC. EXPOSED TO PUBLIC VIEW SHALL BE PAINTED TO MATCH ADJACENT FINISHES AND BE MANUFACTURED BY F&M, GRINNEL, OR CENTRAL FOUNDRY. 15. THE CONTRACTOR SHALL ENSURE THAT ALL SLAB PENETRATIONS WITHIN THE TENANT SPACE (AND THROUGH THE ROOF) ARE PROPERLY SEALED AND REMAIN WATERTIGHT TO PREVENT POSSIBLE WATER LEAKAGE AND/OR DAMAGE. ANY DAMAGE CAUSED FROM FAILURE TO DO SO SHALL BE A CONTRACTOR'S SOLE RISK AND EXPENSE. ALL ROOF AND SLAB PENETRATIONS MADE BY THE CONTRACTOR ARE SUBJECT TO L.L. APPROVAL AS TO LOCATION AND CONSTRUCTION DETAILS. ALL PENETRATIONS IN ROOF AND CEILING SHALL BE FIRE CAULKED. 16. PROVIDE CAST BRASS OR CHROME ESCUTCHEONS WITH SET SCREW DEEP TYPE, TO COVER SLEEVES OR OF A SIZE TO COVER FITTING PROJECTIO , PROVIDE ESCUTCHEONS FOR ALL EXPOSED PIPING THROUGH WALLS, FLOORS, AND EXPOSED CEILINGS. 17. THE CONTRACTOR SHALL CORE DRILL EXISTING FLOOR SLAB AS REQUIRED FOR INSTALLATION OF UNDERSLAB UTILITIES. CONTRACTOR MUS COORDINATE ALL INSTALLATION OF BELOW -SLAB SERVICES WITH L.L. ALL MODIFICTIONS TO THE SLAB SHALL BE REPAIRED BY APPROVED L. . METHODS THAT MEET OR EXCEED THE ORIGINAL SLAB DESIGN INCLUDING WATERPROOFING. THE CONTRACTOR SHALL PROPERLY SLEEVE AND SEAL ALL PENETRATIONS TO COMPLY WITH L.L AND CODE REQ.'S. 18, ALL UTILITIES NOT RE -USED SHALL BE CAPPED -OFF AND REMOVED. DISPOSAL SHALL B "ER L.L. APPROVED METHOD(S). NO UTILITES SHALL BE ABANDONED IN PLACE. 19. CO ORDINATE ALL PENETRATIONS FLOOR DRAINS/SINKS W/ WATERPROOFING OF SLAB. NOTE: * THE DOMESTIC WATER PIPING SYSTEM SHALL BE FLUSHED WITH CLEAN POTABLE WATER UNTIL CONTAMINATED WATER DOES NOT APPEAR AT THE OUTLET AND SHALL BE FILLED WITH A SOLUTION CONTAINING 50 PPM OR CHLORINE AND ALLOWED TO STAND AS REQUIRED BY CODE BEFORE FLUSHING. THE SYSTEM SHALL BE FLUSHED COMPLETELY WITH CLEAR WATER UNTIL ALL RESIDUAL CHLORINE CONTENT IS REMOVED. CHLORINATION SHALL BE PERFORMED AFTER ALL PIPING AND FINAL CONNECTIONS AND PRESSURE TESTING HAVE BEEN COMPLETED. RECEIVED CITY OF TUKWILA DEC 0 8 2016 PERMIT CENTER DATE: 11-4-16 JOB NO: 1670 DRAWN: CHECKED: J:=1 Anna ELD SOUTHCENTER REVISIONS 4, 4410 W. MELROSE AVENUE TAMPA, FLORIDA 33629 TEL. 813.333.2717 FAX. 813.289.3332 SEAL TT TATE, A EAOf WASHINGTON CONTRACTOR SHALL VERIFY AND INSPECT ALL EXISTING PLUMBING FIXTURES AND LINES, COORDINATE WMND OWNER AND REPAIR AND/OR REPLACE ANY DAMAlYR NON FUNCTIONING EXISTING FIXTURES OR LINES. PLUMBING WASTE AND WATER PLANS SHEET NUMBER P1 .0 GAS EQUIPMENT SCHEDULE MARK EQUIPMENT DISTANCE TO METER 13 GRIDDLE 0 CFH REQUIRED 36 CONN. SIZE BTUH 3/4" 15 (2) 2 CHAMBER WOK 0 240 EACH 1-1/4" 36,000 480,000 24 (2) FRYERS 0 110 EACH 3/4" 220,000 TOTAL 736.00 736,000 1 VERIFY DISTANCE TO METER IN FIELD PRIOR TO SUBMITTING BID. COORDINATE THE EXACT ROUTING WITH THE LANDLORD'S FIELD REPRESENTATIVE. DEMAND PRESSURE = 7" W.C. DOWNSTREAM OF METER OR REGULATER GAS SERVICE NOTE TENANTS REQUIRING GAS SERVICE SHALL CONTACT THE LOCAL GAS UTILITY TO MAKE ARRANGEMENTS FOR SERVICE. IF NOT EXISTING, METERS SHALL BE LOCATED AS DETERMINED BY THE LANDLORD. IF NOT EXISTING, PIPING FROM THE METER TO THE TENANT SPACE SHALL BE THE RESPONSIBILITY OF THE TENANTS CONTRACTOR AS SHALL BE THE COORDINATION OF SUCH INSTALLATION WITH THE LANDLORD. PIPING SHALL CONFORM TO ASTM -A-120 STANDARDS AND SHALL BE SCHD. 40 BLACK STEEL THROUGHOUT WITH ALL HIGH PRESSURE CONNECTIONS GREATER THAN 2.5" DIA. WELDED. NO VALVE SHALL BE PLACED IN THE RETURN AIR PLENUMS. DISCHARGE PRESSURE DOWNSTREAM OF THE PRESSURE REGULATOR SHALL BE 7" W.C. MATERIAL FOR GAS PIPING ALL PIPING USED FOR THE INSTALLATION, EXTENSION, ALTERATION, OR REPAIR OF ANY GAS PIPING SHALL BE SCHEDULE 40 BLACK STEEL,ASTMA 120 w/150 LB. BANDED MALLEABLE IRON SCREWED FITTINGS. ALL SUCH PIPE SHALL BE EITHER NEW OR SHALL PREVIOUSLY HAVE BEEN USED FOR NO OTHER PURPOSE THAN CONVEYING GAS. IT SHALL BE IN GOOD CONDITION AND FREE FROM INTERNAL OBSTRUCTIONS. BURRED ENDS SHALL BE REAMED TO THE FULL BORE OF THE PIPE. ALL FITTINGS USED IN CONNECTION WITH THE ABOVE PIPING SHALL BE OF MALLEABLE IRON, YELLOW BRASS (CONTAINING NOT MORE THAN SEVENTY- FIVE (75) PERCENT COPPER) ALL VALVES AND APPURTENANCES USED IN CONNECTION WITH THE ABOVE PIPING SHALL BE OF A TYPE DESIGNED AND APPROVED FOR USE WITH FUEL GAS. GAS CONSTRUCTION NOTES • THE TENANT'S CONTRACTOR SHALL BE RESPONSIBLE FOR COORDINATING AVAILABLE CAPACITY, PRESSURE, SERVICE CONNECTION, UTILITY METER INSTALLATION, ETC., WITH THE LOCAL UTILITY AND THE LANDLORD. • CONFIRM CODE RESTRICTIONS FOR LOCATING GAS PIPING IN RETURN AIR PLENUM. • ROOF- MOUNTED GAS PIPING SHALL BE INSTALLED ON FACTORY FABRICATED ROOF EQUIPMENT SUPPORTS EVERY 5' OR AT ELBOWS. ALL GAS PIPING SHALL BE FINISHED WITH TWO COATS OF A RUST INHIBITIVE PRIMER, ONE COAT OF FINAL PAINT (COLOR PER L.L.) AND IDENTIFICATION LABELS. • THE CONTRACTOR SHALL VERIFY THE SIZE OF THE EXISTING SERVICE AND GAS METER. THE CONTRACTOR IS RESPONSIBLE FOR REPLACING EXISTING COMPONENTS IF THEY ARE INADEQUATE FOR THE NEW REQUIREMENTS OR INOPERABLE. COORDINATE REPLACEMENT COMPONENT SPECIFICATIONS WITH THE LANDLORD FIELD REP. AND LOCAL UTILITY. ROOF CEILING EXHAUST HOOD FLEXIBLE APPLIANCE CONNECTOR FURNISHED BY OTHERS AND INSTALLED BY PLUMBING CONTRACTOR WITH SWIVEL JOINTS IN BOTH ENDS. QUANTITY AND SIZE OF CONNECTIONS AS REQUIRED BY EQUIPMENT SERVED. PROVIDE GAS COCK LOCATED WHERE ACCESSIBLE BESIDE OR ABOVE EQUIPMENT Itt TYPICAL 6" DIRT LEG DO NOT INSTALL VALVES IN CEILING SPACE GAS COCK WITH LEVER HANDLE PLUMBING CONTRACTOR SHALL INSTALL AUTOMATIC GAS SHUT-OFF VALVE FURNISHED BY OTHERS PIPE DROP OF SIZE AND AT LOCATION SHOWN ON PLAN GAS PIPE HEADER ALONG WALL BEHIND COOKING EQUIPMENT, APPROXIMATELY 12" ABOVE FLOOR, WITH SCREWED FITTINGS, SIZES AS SHOWN ON PLANS TYPICAL PIPE SUPPORT ANCHORED TO WALL TYPICAL 6" DIRT LEG PIPING ARRANGEMENT SHOWN IS SCHEMATIC. ADJUST AS REQUIRED TO SUIT ACTUAL CONDITIONS. ATTACH RISER AND HEADER TO WALL WITH 1" CLEARANCE BEHIND PIPE. MAKE FINAL CONNECTION TO EQUIPMENT AS RECOMMENDED BY MANUFACTURER. INSTALL ANY GAS PRESSURE REGULATORS FURNISHED BY FOOD SERVICE EQUIPMENT CONTRACTOR. COOKING APPLIANCE GAS PIPE SCALE: N.T.S. 240 CFH EXISTING 1-1/2" GAS LINE TO EXISTING GAS METER IN CEILING @ 60' DISTANCE FROM LAST PIECE OF EQUIPMENT. 13 36 CFH 24 110 CFH 1-1/4" 240 CFH 1-1/2" TYPICAL 6" DIRT LEG CONNECT NEW EQUIPMENT TO EXISTING GAS LINE TYP. OF 5 EXISTING AUTOMATIC SOLENOID GAS VALVE TIED TO EXISTING HOOD ANSUL SYSTEM GAS ISOMETRIC SCALE: N.T.S. 1-1/2" EXISTING GAS SHUT OFF VALVE J 1-1/2"-)8„..„. clir 1-1/2" EXISTING ANSUL PULL TIED TO EXISTING HOOD ANSUL SYSTEM THE SYSTEM SHALL AUTOMATICALLY SHUT ALL THE SOURCES OF FUEL & HEAT TO ALL EQUIPMENT PROTECTED BY THE SYSTEM. SHUT -OFFS, VALVES, AND SWITCHES SHALL REQUIRE MANUAL RESET. NOTE: o ALL GAS PIPING GOING TO EQUIPMENT SHALL HAVE A QUICK DISCONNECT AND SAFETY CHAIN (SHORTER THAN GAS LINE). 1/2" 1/2" EXIST. 3/4" 3/4" EXISTING WATER METER AND SHUT OFF VALVE OEXIST. RELOC. 3/4" F EXIST. RELOC. E'Prs 1/2"-x tn.71 C • O N \ ` 1/2" WATER ISOMETRIC SCALE: N.T.S. I 3/4" — • �xjST -1/2" 1/2" EXISTING MAIN —� WATER LINE UP THROUGH FLOOR m EXIST. 1/2> O F 1/2„ 1/2" EXIST. RELOC. 33 3/4" • • EXIST. O` RELOC. 46 EXIST. RELOC. EXIST. RELOC. PLUMBING EQUIPMENT NOTES: O TIE-IN PLUMBING DRAIN LINES TO EXISTING WASTE LINE, CONTRACTOR TO VERIFY EXACT LOCATION IN FIELD. O CONNECT NEW VENT LINES TO EXISTING VENT LINE. CONTRACTOR TO VERIFY EXACT LOCATION IN FIELD. O CONNECT WATER SUPPLY TO EXISTING SUPPLY LINE. CONTRACTOR TO VERIFY EXACT LOCATION IN FIELD. 0INSTALL 6" PIPE CHASE UNDER COUNTER FOR SODA LINES FROM BAG -IN BOX TO SODA DISPENSER. O PROVIDE BACKFLOW PREVENTER AS SHOWN OR WHEREVER BACK SIPHONAGE IS POSSIBLE. 66 FILTERED WATER TO BE SUPPLIED TO THE ICE MACHINE AND SODA SYRUP LOCATIONS ONLY STUDOR MINI -VENT AIR ADMITTANCE VALVE EXISTING 1-1/2" GAS LINE TO EXISTING GAS METER IN CEILING @ 60' DISTANCE FROM LAST PIECE OF EQUIPMENT. EXISTING ANSUL PULL TIED TO EXISTING HOOD ANSUL SYSTEM r T T T -r T T T 1 F F -I-- -I- 4. -I- -I I -+-F+ I -F-F-1 LLJ_1 J J_J GAS PLAN SCALE: 1/4" = 1'-0" EXISTING GAS SHUT OFF VALVE EXISTING AUTOMATIC SOLENOID GAS VALVE TIED TO EXISTING HOOD ANSUL SYSTEM CONNECT NEW EQUIPMENT TO EXISTING GAS LINE TYP. OF 5 ISOMETRIC VIEW STUDOR MINI -VENT AIR ADMITTANCE VALVE STUDOR MINI -VENT AIR ADMITTANCE VALVE EXIST. 40 1 2" (46A\ EXIST. RELOC.r,►r rr EXIST. RELOC. I "— STUDOR MINI -VENT I/-2" AIR ADMITTANCE VALVE EXIST. FCO •••••N� oens......r... `may` 20 2"-v 4-1-1/2" 1 \ 1 \ 1 WASTE ISOMETRIC SCALE: N.T.S. \ 2" „ 1 ♦♦♦ 15 ♦ 2” ♦♦\ 1-1/2" 1t N.♦4„ ♦ • 2''2-j " `♦� ♦ 4 EXIST. VENT LINE UP THROUGH ROOF 2") „ • '' r'' r'' rr rr rr rr rr rr '' rr rr EXIST. ,,rr / O rrr / / 4♦♦ 1 RELOCATE EXISTING ♦♦ \ 3/4" ` STUDOR MINI -VENT AIR \ ADMITTANCE VALVE \ ll ♦�2" FOR EXISTING FLOOR \` INK AS REQUIRED 29 1 _— N. N. • D EXIST. EXIST. RELOC. Ib -033S” EXIST. WASTE LINE DOWN TO EXIST. GREASE INTERCEPTOR EXIST. RELOC. DATE: 11-4-16 JOB NO: 1670 DRAWN: CHECKED: J:=3 Anna ELD SOUTHCENTER REVISIONS 4410 W. MELROSE AVENUE TAMPA, FLORIDA 33629 TEL. 813.333.2717 FAX. 813.289.3332 " SEAL 2" _ NEW....... EW_ -110- �.r.r+..... ��� —;;;;; ..-•-• . -2" ♦s.... EXIST. ♦�� FCO 2" 11 „ STUDOR MINI -VENT AIR ADMITTANCE VALVE 4 EXIST. RELOC. %3” 3".), STUDOR MINI -VENT AIR ADMITTANCE VALVE SEPARATE PERMIT AND APPROVAL REQUIRED EXIST. — INSTALL NEW .2" VENT LINE RECEIVED CITY OF TUKWILA DEC 08 2016 ERMIT CENTER REARCHGISTEREDITECT \ ':`tkii0141:41IATT TE OFA WaA�•,g�,10011 PLUMBING WASTE AND WATER ISOMETRICS, GAS PLAN AND ISOMETRIC SHEET NUMBER P2.0