Permit D16-0336 - COWLITZ TRIBAL HEALTH SERVICES - PHONE / DATA ROOM, HOT WATER HEATER ROOM AND CHILD CARE SPACE
COWLITZ TRIBAL HEALTH SERVICES 15455 65 AVE S D16-0336 Parcel No: Address: City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-438-9350 Web site: http://www.TukwilaWA.gov DEVELOPMENT PERMIT 0003200004 Permit Number: 15455 65TH AVE S Issue Date: Permit Expires On: Project Name: COWLITZ TRIBAL HEALTH SERVICES D16-0336 1/20/2017 7/19/2017 Owner: Name: Address: Contact Person: Name: Address: Contractor: Name: Address: License No: COWLITZ INDIAN TRIBE 1055 9TH AVE , LONGVIEW, WA, 98632 DONN DEVORE 402 15TH AVE E , SEATTLE, WA, 98112 AFFIDAVIT - AARON WORKMAN Il/ Lender: Name: COWLITZ INDIAN TRIBE Address: PO BOX 2547 , LONGVIEW, WA, 98632 Phone: (206) 787-1383 Phone: Expiration Date: DESCRIPTION OF WORK: AN EXISTING INACTIVE FILE AREA WITH AN EXISTING ELECTRIC HOT WATER HEATER WILL BE SPLIT INTO A NEW PHONE/DATA ROOM, ELECTRIC HOT WATER HEATER ROOM, AND NEW CHILD SUPERVISED SPACE. A NEW RECEPTION AREA WILL BE CREATED FROM A STORAGE AREA. Project Valuation: $25,000.00 Type of Fire Protection: Sprinklers: Fire Alarm: YES Type of Construction: VB Electrical Service Provided by: TUKWILA Fees Collected: $991.02 Occupancy per IBC: B Water District: TUKWILA Sewer District: TUKWILA Current Codes adopted by the City of Tukwila: International Building Code Edition: International Residential Code Edition: International Mechanical Code Edition: Uniform Plumbing Code Edition: International Fuel Gas Code: 2015 2015 2015 2015 2015 National Electrical Code: WA Cities Electrical Code: WAC 296-46B: WA State Energy Code: 2014 2014 2014 2015 Public Works Activities: Channelization/Striping: Curb Cut/Access/Sidewalk: Fire Loop Hydrant: Flood Control Zone: Hauling/Oversize Load: Land Altering: Landscape Irrigation: Sanitary Side Sewer: Sewer Main Extension: Storm Drainage: Street Use: Water Main Extension: Water Meter: Volumes: Cut: 0 Fill: 0 Number: 0 No Permit Center Authorized Signature: LJI,QL Date: __)-r/L-17 I hearby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this development permit and agree to the conditions attached to this permit. Signature: Print Name: i"f �c/ar Date: / — l� This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: ***BUILDING PERMIT CONDITIONS*** 2: Work shall be installed in accordance with the approved construction documents, and any changes made during construction that are not in accordance with the approved construction documents shall be resubmitted for approval. 3: All permits, inspection record card and approved construction documents shall be kept at the site of work and shall be open to inspection by the Building Inspector until final inspection approval is granted. 4: All construction shall be done in conformance with the Washington State Building Code and the Washington State Energy Code. 5: Notify the City of Tukwila Building Division prior to placing any concrete. This procedure is in addition to any requirements for special inspection. 6: All wood to remain in placed concrete shall be treated wood. 7: There shall be no occupancy of a building until final inspection has been completed and approved by Tukwila building inspector. No exception. 8: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of this requirement. 9: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206-431-3670). 10: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center. 11: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 12: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431-3670). 15: The total number of fire extinguishers required for an ordinary hazard occupancy with Class A fire hazards is calculated at one extinguisher for each 1,500 sq. ft. of area. The extinguisher(s) should be of the "All Purpose" (3A, 40B:C) dry chemical type. Travel distance to any fire extinguisher must be 75' or less. (IFC 906.3) (NFPA 10, 5.4) 13: Portable fire extinguishers, not housed in cabinets, shall be installed on the hangers or brackets supplied. Hangers or brackets shall be securely anchored to the mounting surface in accordance with the manufacturer's installation instructions. Portable fire extinguishers having a gross weight not exceeding 40 pounds (18 kg) shall be installed so that its top is not more than 5 feet (1524 mm) above the floor. Hand- held portable fire extinguishers having a gross weight exceeding 40 pounds (18 kg) shall be installed so that its top is not more than 3.5 feet (1067 mm) above the floor. The clearance between the floor and the bottom of the installed hand-held extinguishers shall not be less than 4 inches (102 mm). (IFC 906.7 and IFC 906.9) 14: Extinguishers shall be located in conspicuous locations where they will be readily accessible and immediately available for use. These locations shall be along normal paths of travel, unless the fire code official determines that the hazard posed indicates the need for placement away from normal paths of travel. (IFC 906.5) 16: Maintain fire extinguisher coverage throughout. 17: Egress doors shall be readily openable from the egress side without the use of a key or special knowledge or effort. (IFC 1008.1.8.3 subsection 2.2) 18: Dead bolts are not allowed on auxiliary exit doors unless the dead bolt is automatically retracted when the door handle is engaged from inside the tenant space. (IFC Chapter 10) 19: Exit hardware and marking shall meet the requirements of the International Fire Code. (IFC Chapter 10) 20: Door handles, pulls, latches, locks and other operating devices on doors required to be accessible by Chapter 11 of the International Building Code shall not require tight grasping, tight pinching or twisting of the wrist to operate. (IFC 1008.1.9.1) 22: A fire alarm system is required for this project. The fire alarm system shall meet the requirements of N.F.P.A. 72 and City Ordinance #2437. 24: Maintain automatic fire detector coverage per N.F.P.A. 72. Addition/relocation of walls, closets or partitions may require relocating and/or adding automatic fire detectors. 25: Maintain fire alarm system audible/visual notification. Addition/relocation of walls or partitions may require relocation and/or addition of audible/visual notification devices. (City Ordinance #2437) 23: All new fire alarm systems or modifications to existing systems shall have the written approval of The Tukwila Fire Prevention Bureau. No work shall commence until a fire department permit has been obtained. (City Ordinance #2437) (IFC 901.2) 26: An electrical permit from the City of Tukwila Building Department Permit Center (206-431-3670) is required for this project. 27: The maximum flame spread class of finish materials used on interior walls and ceilings shall not exceed that set forth in Table No. 803.9 of the International Building Code. 21: Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (City Ordinances #2436 and #2437) 28: Any overlooked hazardous condition and/or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. 29: These plans were reviewed by Inspector 511. If you have any questions, please call Tukwila Fire Prevention Bureau at (206)575-4407. PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 1700 BUILDING FINAL** 1400 FIRE FINAL 0201 FOOTING 0409 FRAMING 0606 GLAZING 0406 SUSPENDED CEILING 0601 WALL INSULATION CITY OF TUKWILA Community Development Department Public Works Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.TukwilaWA.gov Building Permit No. Project No. btio 01-0 Date Application Accepted: Date Application Expires: 12----(d-d (42 -0-17 (For office use only) CONSTRUCTION PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **Please Print** SITE LOCATION King Co Assessor's Tax No.: 000320-0004 Site Address: 15455 65th Avenue S, Tukwila 98188 Tenant Name: Cowlitz Tribal Health Services Suite Number: PROPERTY OWNER Name: Donn DeVore/Environmental Works Name: Cowlitz Indian Tribe City: Seattle State: WA Zip: 98112 Address: PO Box 2547 Email: ddevore@eworks.org City: Longview State: WA Zip: 98632 CONTACT PERSON — person receiving all project communication Name: Donn DeVore/Environmental Works Address: 402 15th Avenue E City: Seattle State: WA Zip: 98112 Phone: (206) 787-1383 Fax: (206) 329-5494 Email: ddevore@eworks.org GENERAL CONTRACTOR INFORMATION Company Name: None currently selected Address: Address: 402 15th Avenue E City: Seattle State: WA Zip: 98112 Phone: (206) 787-1383 Fax: (206) 329-5494 City: State: Zip: Phone: Fax: Zip: Phone: Contr Reg No.: Exp Date: Tukwila Business License No.: H:Wpplications\Forms-Applications On Line\201 1 Applications\Permit Application Revised - 8-9-1 I.docx Revised: August 2011 bh New Tenant: Floor: ❑ Yes m..No 1 ARCHITECT OF RECORD Company Name: Environmental Works Architect Name: Donn DeVore Address: 402 15th Avenue E City: Seattle State: WA Zip: 98112 Phone: (206) 787-1383 Fax: (206) 329-5494 Email: ddevore@eworks.org ENGINEER OF RECORD Name: Notrequired-urfi 6e�er l-C-orti�ctorseleeted Company Name: None/Not Required Address: C,,a�t Lzx Engineer Name: Address: City: State: Zip: Phone: Fax: Email: LENDER/BOND ISSUED (required for projects $5,000 or greater per RCW 19.27.095) Name: Notrequired-urfi 6e�er l-C-orti�ctorseleeted r Address: C,,a�t Lzx State: vi --p Zip:elder/ 9 City: , jc4t Page 1 of 4 BUILDING PERMIT INFORMATION — 206-431-3670 Valuation of Project (contractor's bid price): $ 25,000 Existing Building Valuation: $ 1,650,000 Describe the scope of work (please provide detailed information): An existing inactive file area with an existing electric hot water tank will be split into a new phone/data room; electric hot water tank room; and new child supervised space. A new reception area will be created from a storage area. Will there be new rack storage? ❑ Yes 0.. No If yes, a separate permit and plan submittal will be required. Provide All Building Areas in Square Footage Below PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: 49 Compact: 0 Handicap: 2 Will there be a change in use? ❑ Yes Z No If "yes", explain: FIRE PROTECTION/HAZARDOUS MATERIALS: ❑ Sprinklers Z Automatic Fire Alarm ❑ None 0 Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? 0 Yes Z No If 'yes', attach list of materials and storage locations on a separate 8-1/2" x 11 " paper including quantities and Material Safety Data Sheets. SEPTIC SYSTEM ❑ On-site Septic System — For on-site septic system, provide 2 copies of a current septic design approved by King County Health Department. H:\Applications\Forms-Applications On Line \2011 ApplicationsTermit Application Revised - 8-9-I1.docx Revised: August 2011 bh Page 2 of 4 Existing Interior Remodel Addition to Existing Structure New Type of Construction per IBC Type of Occupancy per IBC IslFloor 4,311 582 0 0 VB B 2nd Floor 7,162 0 0 0 VB B 3'a Floor Floors thru Basement Accessory Structure* Attached Garage Detached Garage Attached Carport Detached Carport Covered Deck Uncovered Deck PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: 49 Compact: 0 Handicap: 2 Will there be a change in use? ❑ Yes Z No If "yes", explain: FIRE PROTECTION/HAZARDOUS MATERIALS: ❑ Sprinklers Z Automatic Fire Alarm ❑ None 0 Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? 0 Yes Z No If 'yes', attach list of materials and storage locations on a separate 8-1/2" x 11 " paper including quantities and Material Safety Data Sheets. SEPTIC SYSTEM ❑ On-site Septic System — For on-site septic system, provide 2 copies of a current septic design approved by King County Health Department. H:\Applications\Forms-Applications On Line \2011 ApplicationsTermit Application Revised - 8-9-I1.docx Revised: August 2011 bh Page 2 of 4 PUBLIC WORKS PERMIT INFO uvIATION — 206-433-0179 Scope of Work (please provide detailed information): An existing inactive file area with an existing electric hot water tank will be split into a new phone/data room; electric hot water tank room; and new child supervised space. A new reception area will be created from a storage area. Call before you Dig: 811 Please refer to Public Works Bulletin #1 for fees and estimate sheet. Water District ❑ ...Tukwila ❑ ...Water District #125 ❑ ...Water Availability Provided Sewer District ❑ ...Tukwila ❑ ...Sewer Use Certificate ❑...Valley View ❑...Sewer Availability Provided 0 .. Highline ❑ .. Renton ❑ .. Renton ❑ .. Seattle Septic System: 0 On-site Septic System — For on-site septic system, provide 2 copies of a current septic design approved by King County Health Department. Submitted with Application (mark boxes which apply): 0 ...Civil Plans (Maximum Paper Size — 22" x 34") 0 ...Technical Information Report (Storm Drainage) 0 ...Bond ❑ .. Insurance 0 .. Easement(s) Proposed Activities (mark boxes that apply): 0 ...Right-of-way Use - Nonprofit for less than 72 hours ❑ ...Right-of-way Use - No Disturbance 0 ...Construction/Excavation/Fill - Right-of-way 0 Non Right-of-way 0 ❑ ...Total Cut 0 ...Total Fill cubic yards cubic yards ❑ ...Sanitary Side Sewer ❑ ...Cap or Remove Utilities 0 ...Frontage Improvements 0 ...Traffic Control ❑ ...Backflow Prevention - Fire Protection Irrigation Domestic Water ❑ .. Geotechnical Report 0 .. Maintenance Agreement(s) ❑...Traffic Impact Analysis 0 ...Hold Harmless — (SAO) 0 ...Hold Harmless — (ROW) ❑ .. Right-of-way Use - Profit for less than 72 hours ❑ .. Right-of-way Use — Potential Disturbance ❑ .. Work in Flood Zone 0 .. Storm Drainage ❑ .. Abandon Septic Tank ❑.. Curb Cut 0 .. Pavement Cut ❑ .. Looped Fire Line 0 .. Grease Interceptor ❑ .. Channelization 0 .. Trench Excavation 0 .. Utility Undergrounding ❑ ...Permanent Water Meter Size... WO # 0 ...Temporary Water Meter Size.. WO # ❑ ...Water Only Meter Size WO # 0 ...Deduct Water Meter Size ❑ ...Sewer Main Extension Public 0 Private 0 ❑ ...Water Main Extension Public 0 Private 0 FINANCE INFORMATION Fire Line Size at Property Line Number of Public Fire Hydrant(s) 0 ...Water 0 ...Sewer Monthly Service Billing to: Name: 0 ...Sewage Treatment Day Telephone: Mailing Address: City State Zip Water Meter Refund/Billing: Name: Mailing Address: Day Telephone: City State Zip H:\ Applications\Forms-Applications On Line\20I 1 Applications\Permit Application Revised - 8-9-11.docx Revised: August 2011 bh Page 3 of 4 PERMIT APPLICATION NOTES — Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR AUTHORIZED AGENT: Signature: c fi�.I Print Name: Elizabeth Tail Day Telephone: (206) 466-5401 Mailing Address: 15455 65th Ave S Tukwila WA 98188 Date: 12/05/2016 H:Npplications\Forms-Applications On Line \2011 Applications\permit Application Revised - 8-9-11.docs Revised: August 2011 bh City State Zip Page 4 of 4 Cash Register Receipt City of Tukwila DESCRIPTIONS PermitTRAK 1 ACCOUNT 1 QUANTITY I PAID $594.97 D16-0336 Address: 15455 65TH AVE 5 Apn: 0003200004 $594.97 DEVELOPMENT $565.95 PERMIT FEE R000.322.100.00.00 0.00 $561.45 WASHINGTON STATE SURCHARGE B640.237.114 0.00 $4.50 TECHNOLOGY FEE $29.02 TECHNOLOGY FEE TOTAL FEES PAID BY RECEIPT: R10504 R000.322.900.04.00 0.00 $29.02 $594.97 Date Paid: Thursday, January 19, 2017 Paid By: COWLITZ TRIBAL HEALTH SERVICES Pay Method: CHECK 62102 Printed: Thursday, January 19, 2017 4:26 PM 1 of 1 CRWSYSTEMS Cash Register Receipt City of Tukwila DESCRIPTIONS PermitTRAK ACCOUNT QUANTITY PAID $396.05 D16-0336 Address: 15455 65TH AVE 5 Apn: 0003200004 $396.05 DEVELOPMENT $396.05 PERMIT FEE PLAN CHECK FEE TOTAL FEES PAID BY RECEIPT: R10002 R000.322.100.00.00 R000.345.830.00.00 0.00 0.00 $18.85 $377.20 $396.05 Date Paid: Thursday, December 08, 2016 Paid By: COWLITZ INDIAN TRIBE Pay Method: CHECK 61415 Printed: Thursday, December 08, 2016 2:51 PM 1 of 1 CRSYSTEMS INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. Dtte� ©33( CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 Permit Inspection Request Line (206) 438-9350 (206) 431-3670 Project: Cam.;ra TJ13 % "*U Type of Inspection: , iJ» D/NG- ANAL Address: /5V6-5 Sm Me S', Date Called: Special Instructions: Date Wanted: 7-2 9-/ 7 a.m. p.m. Requester: Phone No: Approved per applicable codes. [] Corrections required prior to approval. COMMENTS: e>K 80,i D//{& fij)s L - Inspector: Date: 7 REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 stis p44,34,,f9 'ff/LtNG- Project: Ca WL/ 7Z/ Q Alli. -7771 Type of Inspection: Address: /,5-5-5.- c577+/lie Si Date Called: Special Instructions: Date Wanted: 6 --213 --i 7 a.m. p.m. Requester: i155E 4ZEICI-kiff T Phone No: z 4 --9 '1e 53/D2. Approved per applicable codes. LJ Corrections required prior to approval. COMMENTS: 6 <- _5V5P9j/ j9 LJ7NIC Inspector: Date: REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 03Vp kL-‘ Project:I�� CCU ,T2_ 034L /7W4 Type of Inspection: 6I AV AZ - Address: /.--Z4om' 645774447 4 Date Called: Special Instructions: Date Wa nt d• / �° C 7 m p.m. Requeste . Phone No: Approved per applicable codes. L Corrections required prior to approval. COMMENTS: Ins Inspector: Date:7 9A REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project:Type (.f.�lt.trrz 7lR /-II:Atri of Inspection: cJaIn"6 1_ //�� eti < Address: /.57!4`.r Ayr S Date Called: Special Instructions: Date Want :� 17 Requestr: ! iN Phone No: "SO(...)- • 23 - C -324i Approved per applicable codes. M Corrections required prior to approval. COMMENTS: 1C L APPi t i' t€ "D- emetz Pnfe44-6Ase.m... ,Ir., - ars r� 2As Oa, e ,APPP Date: REINSPECTION FEE REQUIRED. Prior to next inspectlOn. fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION NO. INSPECTION RECORD Retain a copy with permit bib -e926 PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project: Ca4.4r%L' ' 11'„1 / % T,r/i Type o spection: ,A 1 Aro Address: /5-/ S—s"` &774 ATV S Date Called: Special Instructions: Date Wanted: if 7 m. p.m. Requester: DJ's/ Phone No: -&3- &z Approved per applicable codes. Corrections required prior to approval. COMMENTS: Inspector: Date: 1r VY7 REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 14/6 -o 531e Project: atoz trZ. 7721I 4 L Type o nspection: -Fralkuvil lief Address: /Sill Sr 6S" A " 5 Date Called: Special Instructions: Date Want ed: i/0/7 ANY ai. m. Requester: ,+ A Phone No: � 67.6 —q� ® �% - G//'�� Q//y�j c O g 0 Approved per applicable codes. Q Corrections required prior to approval. COMMENTS: ,fibT Rrt'kA� Inspector: REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. i INSPECTION NUMBER INSPECTION RECORD Retain a copy with permit PERMIT NUMBERS CITY OF TUKWILA FIRE DEPARTMENT 206-575-4407 Project:,,.r Wt,7-z Tiz<B Type of Inspection: r"` (-"" Address: Suite #: l 57.-5 S- 6s r /E S Contact Person: 3-2 SScrz Special Instructions: Phone No.: Approved per applicable codes. Corrections required prior to approval. COMMENTS: Sprinklers: AJ Fire Alarm: --/- Hood & Duct: Monitor: Pre -Fire: Permits: — F— /� fit--'9----MA l 7 /2 E-62 — 607-n7 /s T /1/6, f"( :"7/7 D . -- C' (_ .- 5----')--- 4-4 6-7- T 5 e__(-1 V u L t //NJsp. C -.//1- a:v1 C_C Needs Shift Inspection: Sprinklers: AJ Fire Alarm: --/- Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: Inspector: F-7),/ g4— Date:4/�)h._ Hrs.: $100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. Billing Address Attn: Company Name: Address: City: State: Zip: Word/Inspection Record Form.Doc 3/14/14 T.F.D. Form F.P. 113 Lighting Summary LGT-SUM 2015 Was'.ington State Energy Code Compliance Forms for Commercial Buildings including R2, R3, R4 over 3 stories and all R1 Project Info Project Title: Cowlitz Tribal Health Services Renovation Date 12/1/2016 Compliance forms do not Applicant Information. Provide contact information for individual who can respond to inquiries about compliance form information provided. For Building Department Use require a password to Company Name: Cowlitz Tribe use. Instructional and Company Address: 15455 65th Avenue S, Tukwila WA 98188 calculating cells are write - Applicant Name: Donn DeVore, AIA r 1 protected. Applicant Phone: 2067871383 Applicant Email: ddevore@eworks.org Project Description New Building ❑ Addition Include PROJ-SUM form (included in envelope forms workbook) 1 Alteration with lighting complliance -/ Plans Included forms. Building Additions Compliance Method Interior lighting Exterior lighting Refer to Section C502.2.6 for additional Lighting systems in addition area comply with all applicable provisions as a stand alone new construction project El El requirements. Lighting systems in addition are combined with existing building lighting systems to demonstrate compliance ❑ Addition Is combined with existing: For interior lighting projects, include new + existing interior lighting fixture wattage in Wattage table in LTG-iNT-BLD or LTG -INT -SPACE form. For exterior lighting projects; include new + existing exterior lighting fixture wattage Tradable and Proposed Non -Tradable Lighting Wattage tables in LTG -EXT form. Proposed Lighting in Proposed Interior and Exterior Lighting Power Interior lighting Parking garage Exterior lighting Lighting Alterations 50% or more of existing are replaced el❑ Select all Lighting Power and Lighting Control elements that apply to the scope of the retrofit project. If project includes a Less than 50% of existing are replaced ❑ ❑ ❑ . combination of spaces where less than 50% of the existing fixtures are replaced in 50% Lamp and/or ballast replacement only — existing total wattage not increased IIII❑ ❑ some spaces. and or more of the fixtures are replaced in others, then provide separate lighting power compliance forms for the two retrofit conditions. Spaces undergoing the same type of retrofit may be combined into one lighting power compliance form. Refer to Section C503.6 for additional 50% or more replaced - Total lighting power of new LPA per Sections C405.4.2 and C405.5.2. Include Lighting Wattage table in LTG -INT -BLD. LTG -INT Less than 50% replaced - Total lighting power of total lighting power prior to alteration. include new Wattage table in LTG-iNT-BLD. LTG -INT -SPACE 50% threshold applies to number of luminaries for installed wattage for exterior luminaires. -SPACE new + or interior + existing -to -remain fixtures shall comply with total new + existing -to -remain fixtures in Proposed or LTG -EXT form. + existing -to -remain fixtures shall not exceed the existing -to -remain fixtures in the Proposed Lighting LTG -EXT form. spaces and parking garages. and total requirements. Lighting Controls Interior lighting Parking garage Exterior lighting All alteration lighting controls shall be comiaaiwienarilqieri.G.49SW New wiring installed to serve added REVIEWED FOR fixtures and/or fixtures relocated to new circuit(s) ❑ ❑ ❑ CODE COMPLIANCE APPROVED DEC16 2016 . No changes are bein made to the inejtyorixT ;erg y;�„� �fi�YhfP ` �r�`f r New or moved lighting panel Interior space is reconfigured - Luminaires unchanged or relocated only New wiring or circuit - For interior lighting, provide sensor controls per C405.2.1, daylight responsive controls per C405.2.5. For exterior lighting, provide New or moved panel - Provide all applicable lighting time switch controls per C405.2.2. Reconfigured interior space - Provide all required ■ ❑ controls required required manual controls per C405.2.3, per C405.2.4 and application controls per C405.2. 7. controls as noted for New bring lighting controls that apply to a __- occupancy specific lighting and automatic new interior .space. changed. Application specific lighting control provisions per C405.2.5 do not apply to reconfigured spaces. Change of Space Use ., Identify LTG Existing interior lighting systems in areas under -going a change in space use are upgraded to comply with LPAs for the new space types per Tables C405.4.2(1) or C405.4.2(2). interior spaces requiring LPD upgrade to the current Code in Proposed Lighting Wattage table in -INT -BLD or LTG -INT -SPACE form. b1(O33( � WM�f �Lr�t CITY i I &ICWILA DEC 08 2016 PERMIT CENTER Lighting Summary, cont. LGT-SUM 2015 Washington State Energy Code Compliance Forms for Commercial Buildings including R2, R3, R4 over 3 s Project Title: �V Cowlitz Tribal Health Services Renovation Date 12/1/2016 Interior Lighting System Description „ t., _1 LED lay in fixtures in new ceiling grid. Interior Lighting Power Allowance Method ❑ Building Area Method .1 Space -by -space Method Select method used in project. Interior Lighting Controls ✓ All C405.2.1 - C405.2.8 Controls ❑ C405.2 Exception 5 Luminaire Level Lighting Control (LLLC) ❑ Additional Efficiency Package Option C406.4 Enhanced digital lighting controls To comply with C406.4, no less than 90% of the total installed interior lighting power shall comply with the required controls per C406.4. Dwelling Unit Interior Lighting Permanently installed interior lighting fixtures in dwelling units comply with: ®i 0 C405.2 thru C405.5 Commercial Lighting Controls and LPA 0 0406.3 High Efficacy Lighting 0 Exterior Lighting System Description No changes. Interior Lighting - Space -By -Space Method LTG -INT -SPACE 2015 Washington Sttte Energy Code Compliance Forms for Commercial Buildings including R2, R3, R4 over 3 stories and all R1 Revised August 20 Project Title: Cowlitz Tribal Health Services Renovation Date 12/1/2016 r iBuilding Calculaton Area NOTE 8 0 Q Addition - Q Addition stand alone + existing O Spaces where < 50% of O Spaces where L•50% of O luminaires are replaced luminaires are replaced Department Use For LPA Calculation Type ® Standard O Additional Efficiency Package Option O C406.3 Reduced Interior Lighting Power To comply with C406.3, the Proposed LPD shall be 25% lower than the Target LPA. Refer to C406.3 for additional requirements. Maximum Allowed Lighting Wattage NOTE 1 4 Location (plan #, room #) Space Type Ceiling Height NOTE 2 Gross Interior Area in ft2 Allowed Watts per ft2 Watts Allowed (watts/ft2 x area) 121 Classroom/lecture/training 2x4 LED Ceiling Light Fixture 303 1.000 303 120 Office: Enclosed 12 9 0. 8 90 115 114 Computer room 116 1 . 370 159 Lobby Art/Exhibit Display Allowance from LTG -INT -DISPLAY NOTE 8 Total Area Retail Display 548 LTG -INT -DISPLAY Allowed Watts Allowance from 577 Proposed Lighting Wattage "i's Location (plan #, room #) Fixture Description NOTE 4. 5, 6 Number of Fixtures Watts/ Fixture NOTE 7 Watts Proposed 121 2x4 LED Ceiling Light Fixture 4 36 145 120 2x4 LED Ceiling Light Fixture 2 36 72 114 2x4 LED Ceiling Light Fixture 2 36 72 Proposed Retail Display Lighting from LTG -INT -DISPLAY Total Proposed Watts may not exceed Total Allowed Watts for Interior Lighting Total Proposed Watts 289 Interior Lighting Power Allowance COMPLIES Note 1 - List all unique space types per Table C405.4.2(2) that occur in the project scope. Select space type category per from drop down menu. Note 2 - Indicate ceiling height for atriums and spaces utilizing the ceiling height adjustment per Table C405.4.2(2), Footnotes d thru f. Note 3 - List all proposed lighting fixtures including exempt lighting equipment and existing -to -remain fixtures. Note 4 - For proposed Fixture Description, indicate fixture type, lamp type (e.g. T-8), number of lamps in the fixture, and ballast type (if included). For track lighting, list the length of the track (in feet) in addition to the fixture, lamp, and ballast information. Note 5 - For lighting equipment eligible for exemption per C405.4.1, note exception number and leave Watts/Fixture blank. Note 6 - Existing -to -remain fixtures shall be included in the Proposed Lighting Wattage table in the same manner as new fixtures. Identify as existing in fixture description. Note 7 - For proposed Watts/Fixture enter the luminaire wattage for installed lamp and ballast using manufacturer or other approved source. For luminaires with screw-in lamps, enter the manufacturer's listed maximum input wattage of the fixture (not the lamp wattage). For low voltage lighting, enter the wattage of the transformer. For line voltage track/busway systems, enter the larger of the attached luminaire wattage or 50 watts/lineal foot, or enter the wattage limit of permanent current limiting device. Note 8 - Lobby Art/Exhibit Display Allowance is independent of the Maximum Allowed Lighting Wattage. Note 9 - Calculation Area Details: a. Lighting fixtures in a building addition may comply as a stand alone project, or they may be combined with the overall existing building lighting systems to demonstrate compliance. Refer to C502.1. b. For alterations and building additions, provide Space Types and gross interior areas in the Maximum Allowed Lighting Wattage table. If a building addition will comply as combined with the overall existing building lighting systems, include all applicable existing Space Types and gross interior areas. c. If less than 50% of existing lighting fixtures will be replaced, provide total existing lighting wattage (prior to alteration) in the space provideq PERMIT COORD COPY PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: D16-0336 DATE: 12/08/16 PROJECT NAME: COWLITZ TRIBAL HEALTH SERVICES SITE ADDRESS: 15455 65 AVE S X Original Plan Submittal Response to Correction Letter # Revision # before Permit Issued Revision # after Permit Issued DEPARTMENTS: Building Division 19u lic Wo L (A-- iirc° A -r\ Lys ke Fire Prevention Structural Planning Division Permit Coordinator PRELIMINARY REVIEW: Not Applicable (no approval/review required) DATE: 12/13/16 Structural Review Required REVIEWER'S INITIALS: DATE: n APPROVALS OR CORRECTIONS: Approved Corrections Required n (corrections entered in Reviews) Approved with Conditions Denied (ie: Zoning Issues) DUE DATE: 01/10/17 n Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire 0 Ping 0 PW ❑ Staff Initials: iznsnou CITY OF TUKWILA Department of Community Development 6300 Southcenter Boulevard, Tukwila, WA 98188 Telephone: (206) 431-367o FAX (206) 431-3665 E-mail: tukplanpci.tukwila.wa.us Permit Center/Building Division 206 431-3670 Public Works Department 206 433-0179 Planning Division 206 431-3670 AFFIDAVIT IN LIEU OF CONTRACTOR REGISTRATION PERMIT NO: D/6 _ 3 1" STATE OF WASHINGTON) ) ss. COUNTY OF KING , states as follows: [please print name] 1. I have made application for a permit from the City of Tukwila, Washington. 2. I understand that state law requires that all building construction contractors be registered with the State of Washington. The exceptions to this requirement are stated under Section 18.27.090 of the Revised Code of Washington, a copy of which is printed on the reverse side of this Affidavit. I have read or am familiar with RCW 18.27.090. 3. I understand that prior to issuance of a permit for work which is to be done by any contractor, the City of Tukwila must verify either that the contractor is registered by the State of Washington, or that one of the exemptions stated under RCW 18.27.090 applies. 4. In order to provide verification to the City of Tukwila of my compliance with this requirement, I hereby attest that after reading the exemptions from the registration requirement of RCW 18.27.090, I consider the work authorized under this permit to be exempt under number l', and will therefore not be performed by a registered contractor. 5. I understand that the licensing provision of RCW 19.28.161 through 19.28.271 shall not apply to persons making electrical installations on their own property or to regularly employed employees working on the premises of their employer. The proposed electrical work is not for the construction of a new building for rent, sale or lease. I understand that I may be waiving certain rights that I might otherwise have under state law in any decision to engage an unregistered contractor to perform construction work. - LAURIE A. WERLE NOTARY PUBLIC STATE OF WASHINGTON COMMISSION EXPIRES MAY 29, 2018 Owner/Owner's Agent* Signed and sworn to before me this 20 da of a-7 , 20/.7. NY AR PUBLIC in and for the State of Washington Residing at Name as commissioned: My commission expires: 651)- , 5/)- , County 18.27.090 Exemptions. The registration provisions of this chapter do not apply to: 1. An authorized representative of the United States government, the state of Washington, or any incorporated city, town, county, township, irrigation district, reclamation district, or other municipal or political corporation or subdivision of this state; 2. Officers of a court when they are acting within the scope of their office; 3. Public utilities operating under the regulations of the utilities and transportation commission in construction, maintenance, or development work incidental to their own business; 4. Any construction, repair, or operation incidental to the discovering or producing of petroleum or gas, or the drilling, testing, abandoning, or other operation of any petroleum or gas well or any surface or underground mine or mineral deposit when performed by an owner or lessee; 5. The sale of any finished products, materials, or articles of merchandise that are not fabricated into and do not become a part of a structure under the common law of fixtures; 6. Any construction, alteration, improvement, or repair of personal property performed by the registered or legal owner, or by a mobile/manufactured home retail dealer or manufacturer licensed under chapter 46.70 RCW who shall warranty service and repairs under chapter 46.70 RCW; 7. Any construction, alteration, improvement, or repair carried on within the limits and boundaries of any site or reservation under the legal jurisdiction of the federal government; 8. Any person who only furnished materials, supplies, or equipment without fabricating them into, or consuming them in the performance of, the work of the contractor; 9. Any work or operation on one undertaking or project by one or more contracts, the aggregate contract price of which for labor and materials and all other items is Less than five hundred dollars, such work or operations being considered as of a casual, minor, or inconsequential nature. The exemption prescribed in this subsection does not apply in any instance wherein the work or construction is only a part of a larger or major operation, whether undertaken by the same or a different contractor, or in which a division of the operation is made into contracts of amounts less than five hundred dollars for the purpose of evasion of this chapter or otherwise. The exemption prescribed in this subsection does not apply to a person who advertises or puts out any sign or card or other device which might indicate to the public that he or she is a contractor, or that he or she is qualified to engage in the business of contractor; 10. Any construction or operation incidental to the construction and repair of irrigation and drainage ditches of regularly constituted irrigation districts or reclamation districts; or to farming, dairying, agriculture, viticulture, horticulture, or stock or poultry raising; or to clearing or other work upon land in rural districts for fire prevention purposes; except when any of the above work is performed by a registered contractor; 11. An owner* who contracts for a project with a registered contractor, except that this exemption shall not deprive the owner of the protections of this chapter against registered and unregistered contractors. The exemption prescribed in this subsection does not apply to a person who performs the activities of a contractor for the purpose of leasing or selling improved property he or she has owned for less than twelve months; 12.* Any person working on his or her own property, whether occupied by him or her or not, and any person working on his or her personal residence, whether owned by him or her or not but this exemption shall not apply to any person who performs the activities of a contractor on his or her own property for the purpose of selling, demolishing, or leasing the property; 13. An owner* who performs maintenance, repair, and alteration work in or upon his or her own properties, or who uses his or her own employees to do such work; 14. A licensed architect or civil or professional engineer acting solely in his or her professional capacity, an electrician certified under the laws of the state of Washington, or a plumber certified under the laws of the state of Washington or licensed by a political subdivision of the state of Washington while operating within the boundaries of such political subdivision. The exemption provided in this subsection is applicable only when the person certified is operating within the scope of his or her certification; 15. Any person who engages in the activities herein regulated as an employee of a registered contractor with wages as his or her sole compensation or as an employee with wages as his or her sole compensation; 16. Contractors on highway projects who have been prequalified as required by RCW 47.28.070, with the department of transportation to perform highway construction, reconstruction, or maintenance work; 17. A mobile/manufactured home dealer or manufacturer who subcontracts the installation, set-up, or repair work to actively registered contractors. This exemption only applies to the installation, set-up, or repair of the mobile/manufactured homes that were manufactured or sold by the mobile/manufactured home dealer or manufacturer; i8. An entity who holds a valid electrical contractor's license under chapter 19.28 RCW that employs a certified journeyman electrician, a certified residential specialty electrician, or an electrical trainee meeting the requirements of chapter 19.28 RCW to perform plumbing work that is incidentally, directly, and immediately appropriate to the like -in-kind replacement of a household appliance or other small household utilization equipment that requires limited electric power and limited waste and/or water connections. An electrical trainee must be supervised by a certified electrician while performing plumbing work. Per Washington State Department of Labor and Industries lessee has been interpreted to be equivalent to owner for purposes of exemptions. LEGENDS AND SYMBOLS ABBREVIATIONS BUILDING SECTION SECTION NUMBER SHEET NUMBER WALL SECTION SECTION NUMBER SHEET NUMBER DETAIL REFERENCE ENLARGED PLAN AND DETAIL REFERENCE DETAIL NUMBER SHEET NUMBER INTERIOR ELEVATION DETAIL NUMBER SHEET NUMBER WALL TYPE DOOR NUMBER WINDOW TYPE RELIGHT TYPE A.B. A.C.T. ADJ. ADD. ALT. ALUM. APPROX. ARCH. AUTO. BM. BLDG. BLKG. BSMT. BOT. B.O.F. CAB. C.B. CFM. CLG. CLOS. CLR. C.M.U. C.O. COL. CONC. CONT. CTR C.T. CU d D. DBL. DET. D.F. DIA. DIM. DN. DR. D.S. DW. DWG. DWR. (E), EXIST. EA. E.J. EL., ELEV. ELEC. E.O. EQ. EQUIP. E.W. F.D.C. Angle At Anchor Bolt Acoustical Ceiling tile Adjustable Additional Alternate Aluminum Approximate Architectural Automatic Beam Building Blocking Basement Bottom Bottom of Footing Cabinet Catch Basin Cubic Feet per Minute Center Line Ceiling Closet Clear Concrete Masonry Unit Cleanout Column Concrete Continuous Center Ceramic Tile Cubic Penny (nails) Dryer or Depth Double Detail Douglas Fir Diameter Dimension Down Door Downspout Dishwasher Drawing Drawer Existing Each Expansion Joint Elevation Electrical Electrical Outlet Equal Equipment Each Way Fire Department Connection EXT. F.B. F.D. FDN. F.E. FIN. FL. F.O.I.C. F.O.S. F.R.P. FT or FTG. GA. GALV. GL. G.L.B. G.M.M.U. G.W.B. H.B. H.C. HDR. HD.WD, HDW. H, HGT H.M. HORIZ. HTR. H.V.A.C. H.W. I.B.C. I.D. IN or" INSUL. INT. LAV. LB. L.F. L.S. L.S.L. L.V.L. MATL. MAX. MECH. MET. MFR. MIN. MISC. M.O. N. (N) N.I.C. NO., # N.T.S. Exterior Flush Beam Floor Drain Foundation Fire Extinguisher Finish Floor Furnished by Owner Installed by Contractor Face of Stud Fiberglass Reinforced Panel Feet, Foot or Footing Gauge Galvanized Glass or Glazing GlueLam Beam Glass Mesh Morter Unit Gypsum Wall Board Hose Bibb Hollow Core Header Hard Wood Hardware Height Hollow Metal Horizontal Heater Heating, Ventilation and Air Conditioning Hot Water Tank International Bldg Code Inside Diameter Inch, Inches Insulation Interior Lavatory Pound Linear Feet Lightswitch Laminated Strand Lumber Laminated Veneer Lumber Material Maximum Mechanical Metal Manufacturer Minimum Miscellaneous Masonry Opening North New Not In Contract Number Not to Scale OA. Overall OBS. Obscure O.C. On Center O.D. Outside Diameter OPP. Opposite O.S.B. Oriented Strand Board P.L., Q Property Line PL. Plate P.LAM. Plastic Laminate PLYWD. Plywood PR. Pair P.R.V. Pressure Reducer Valve P.S.F. Pounds per Square Foot P.S.I. Pounds per Square Inch P.S.L. Paralell Strand Lumber P.T. Pressure Treated R. Riser RAD. Radius REINF. Reinforced, Reinforcing REQ'D. Required REV. Revision R.O. Rough Opening SBC Seattle Building Code S.C. Solid Core S.D. Smoke Detector S.F. Square Foot or Feet S.GL. Safety Glass SHT. Sheet SIM. Similar S&P Shelf and Pole SPEC. Specification SQ. Square STD. Standard STOR. Storage T. Tread or Thickness TEL. Telephone T&G Tongue and Groove T.O.C. Top of Concrete T.O.W. Top of Wall TYP. Typical U.N.O. Unless Noted Otherwise V.C.T. Vinyl Composition Tile VERT. Vertical V.G. Vertical Grain V.I.F. Verify in Field W. Washer or Width W/ With WAC Washington Administrative Code WD Wood W/O Without W.R. Water Resistant W.S.E.C. Washington State Energy Code W.W.F. Welded Wire Fabric GENERAL NOTES 1. THE CONTRACTOR IS RESPONSIBLE FOR PROVIDING A WEATHERTIGHT BUILDING, DETAILS AND OMISSSIONS NOTWITHSTANDING. ALL DRAWING CONFLICTS OR CONDITIONS ARE TO BE BROUGHT TO THE IMMEDIATE ATTENTION OF THE ARCHITECT FOR RESOLUTION. IF CONFLICTS AMONG DRAWINGS SHOULD OCCUR, THE LARGER SCALE DRAWING SHALL GOVERN. CONFLICTS BETWEEN THE DRAWINGS AND SPECIFICATIONS SHALL BE GOVERNED BY THE SPECIFICATIONS. 2. CONTRACTOR SHALL VERIFY ALL LEVELS, DIMENSIONS, AND EXISTING CONDITIONS ON THE JOB BEFORE PROCEEDING AND SHALL REPORT ANY DISCREPANCIES TO THE PROJECT ARCHITECT FOR RESOLUTION PRIOR TO PROCEEDING. DIMENSIONS NOTED AS PLUS OR MINUS INDICATE UNVERFIED DISTANCE BETWEEN EXISTING REFERENCE AND ARE APPROXIMATE. 3. NOTED DIMENSIONS TAKE PRECENDENCE OVER SCALED DIMENSIONS. DO NOT SCALE THE DRAWINGS. 4. DOOR OPENINGS ARE LOCATED 4-1/2" FROM FACE OF WALL TO THE DOOR JAMB, UNO. 5. ALL DIMENSIONS TO NEW MATERIALS ARE MEASURED TO THE FACE OF FRAMING, UNO. ALL DIMENSIONS TO EXISTING MATERIALS ARE MEASURED TO THE FACE OF EXISTING FINISH SURFACE, UNO. 6. SEPARATE PERMITS WILL BE REQUIRED BY SUBCONTRACTORS FOR CHANGES TO THE MECHANICAL, ELECTRICAL, PLUMBING, SPRINKLER AND FIRE ALARM SYSTEMS. BUILDING CODE INFORMATION ALL WORK SHALL COMPLY WITH THE FOLLOWING CODES: IBC WITH CHAPTER 51-50 WAC - 2015 ICC ANSI A117.1 FOR ACCESSIBILITY - 2009 INTERNATIONAL MECHANICAL CODE WITH CHAPTER 51-52 WAC - 2015 WASHINGTON CITIES ELECTRICAL CODE NFPA 70 - 2014 INTERNATIONAL ENERGY CONSERVATION CODE AS AMENDED BY THE STATE OF WASHINGTON FOR COMMERCIAL BUILDINGS - 2015 INTERNATIONAL FIRE CODE AS AMENDED BY THE STATE OF WASHINGTON - 2015 INTERNATIONAL BUILDING CODE SUMMARY OCCUPANCY GROUP: B CONSTRUCTION TYPE: VB ALLOWABLE AREA PER FLOOR PER TABLE 506.2: 9,000 SF MAXIMUM NUMBER OF FLOORS PER 506.2.3: 3 FLOORS ACTUAL NUMBER OF FLOORS: 2 SPRINKLERED: NO TOTAL AREA OF WORK: 582 SF CLASSIFICATION OF AREAS OF WORK: - AN EXISTING INACTIVE FILE AREA WITH AN EXISTING HOT WATER TANK (461 SF) WILL BE SPLIT INTO: 1) NEW PHONE/DATA ROOM (116 SF) 2) ELECTRIC HOT WATER TANK ROOM (32 SF) 3) NEW CHILD SUPERVISED SPACE FOR CHILDREN WHOSE GUARDIANS ARE ON SITE (303 SF) - A NEW RECEPTION AREA/ENTRY WILL BE CREATED FROM AN EXISTING STORAGE ROOM (129 SF) TOTAL BUILDING AREA: 11,473 SF LOWER LEVEL: 4,311 SF UPPER LEVEL: 7,162 SF INCIDENTAL USES PER IBC TABLE/SECTION 509: - STORAGE AREAS LESS THAN 100 SF - AREAS LESS THAN 10% OF THE BUILDING AREA OF THE STORY IN WHICH THEY ARE LOCATED - IBC SECTION 305.3.3 - A FACILITY HAVING FIVE OR FEWER CHILDREN RECEIVING SUCH DAY CARE SHALL BE CLASSIFIED AS PART OF THE PRIMARY OCCUPANCY. - ALL AREAS SHALL NOT BE REQUIRED TO BE FIRE SEPARATED. INTERIOR WALL AND CEILING FINISHES SHALL BE CLASS C PER IBC TABLE 803.11 MAXIMUM OCCUPANT LOADS PER IBC TABLE 1004.1.2 - BUSINESS AREAS: 100 GROSS: = 1.3 PERSONS - DAY CARE AREAS: 35 NET: = 8.7 PERSONS - ACCESSORY STORAGE 300 GROSS = 0.5 PERSONS - TOTAL = 10.5 PERSONS - EXISTING = 1.5 PERSONS - DIFFERENCE = 9.0 PERSONS - OCCUPANT LOAD PER 2008 PERMIT = 43 AT LOWER LEVEL AND 72 AT UPPER LEVEL. - NEW OCCUPANT LOAD = 52 AT LOWER LEVEL AND 72 AT UPPER LEVEL EGRESS WIDTHS PER IBC 1005 - 0.3 INCH/PER OCCUPANT FOR STAIRS - 0.2 INCH PER OCCUPANT FOR OTHER EGRESS COMPONENTS. - EXISTING MIN STAIR WIDTH - NEW MIN STAIR WIDTH - EXISTING STAIR WIDTH - EXISTING MIN CORR WIDTH - NEW MIN CORR WIDTH - EXISTING CORRIDOR WIDTH = 0.3 x 43/2 = 6.5 INCHES = 0.3 x 52/2 = 7.8 INCHES = 44 INCHES MIN. = 0.2 x 43 = 8.6 INCHES = 0.2 x 52 = 10.4 INCHES = 48 INCHES MIN. ACCESSIBILITY PER CHAPTER 11/ANSI A117.1 PROVIDE ACCESSIBILITY FOR CONTROLS, DOORS AND DOOR HARDWARE, THRESHOLDS, CLEARANCES, OPENING WIDTHS, ENTRANCES, ROUTE, AND PARKING. CONTROLS FOR APPLIANCES, LIGHTING, OUTLETS TEMPERATURE SHALL BE LOCATED BETWEEN 15" AND 48" ABOVE FINISHED FLOOR PER 308.3. DOORS SHALL NOT REQUIRE MORE THAN 5 LBS FOR PUSHING OR PULLING OPEN INTERIOR SWINGING DOORS. OTHER SWINGING DOORS SHALL NOT REQUIRE MORE THAN A 15 LB FORCE TO RELEASE THE LATCH. HANDLES, PULLS, LATCHES, LOCKS AND OTHER OPERABLE PARTS SHALL HAVE A SHAPE THAT IS EASY TO GRASP WITH ONE HAND AND DOES NOT REQUIRE TIGHT GRASPING, PINCHING OR TWISTING OF THE WRIST TO OPERATE. THRESHOLDS AT DOORS SHALL BE A MAXIMUM OF 1/2" IN HEIGHT. CLEARANCES AT DOORS SHOWN ON PLANS. GLAZED DOORS SHALL HAVE A MINIMUM 10" BOTTOM RAIL. OPENING CLEAR WIDTHS SHALL NOT BE LESS THAN 32" IN WIDTH. 2 ACCESSIBLE SPACES SHALL BE PROVIDED WHEN THE TOTAL NUMBER OF PARKING STALLS IS 26 TO 50.1 OF THE ACCESSIBLE PARKING STALLS SHALL BE A VAN STALL WHICH SHALL BE OF A STANDARD STALL LENGTH BY 8 FEET WIDE PROVIDED THAT THERE IS AN ADJACENT AISLE 8 FEET WIDE FOR THE FULL LENGTH OF THE PARKING STALL. SAFETY GLAZING PER CHAPTER 24 REQUIRED IN DOOR GLAZING; GLAZING THAT IS WITHIN 24" OF A DOOR; AND GLAZING THAT IS WITHIN 18" OF THE FLOOR SURFACE OR GREATER THAN 9 SQUARE FEET. SEE DOOR AND WINDOW SCHEDULE FOR ENERGY CODE REQUIREMENTS. ENERGY CODE PER WAC 51-11C (2015) OFFICE AREAS SHALL HAVE A MAXIMUM LIGHT FIXTURE WATTAGE OF 0.89 WATTS PER SF (ROOM 120) CLASSROOM AREAS SHALL HAVE A MAXIMUM LIGHT FIXTURE WATTAGE OF 1.0 WATTS PER SF (ROOM 121) COMPUTER ROOMS SHALL HAVE A MAXIMUM LIGHT FIXTURE WATTAGE OF 1.37 WATTS PER SF (ROOM 114) OCCUPANCY SENSOR CONTROLS SHALL BE PROVIDED FOR LIGHTING.PER C405.2. SEE FLOOR PLANS AND SCHEDULES FOR U -VALUES FOR GLAZING AND DOORS. COWLITZ TRIBAL HEALTH SERVICES OFFICE TENANT IMPROVEMENT 15455 65TH AVENUE SOUTH - TUKWILA, WASHINGTON PLANNING APPROVED • No changes can be made to these plans without approval from the Planning Division of DCD Approved By: 1-- 417rOWh Date: 01- up PROJECT INFORMATION DRAWING INDEX NAME OF PROJECT: COWLITZ TRIBAL HEATH SERVICES TENANT IMPROVEMENT LOCATION: 15455 65TH AVENUE SOUTH TUKWILA, WASHINGTON 98188 PROJECT DESCRIPTIDN: RENOVATION OF EXISTING STORAGE AREAS INTO CHILD CARE FOR FIVE OR LESS CHILDREN, RECEPTION AREA, OUTDOOR PLAY AREA AND EXPANSION OF EXISTING DECK. TENANT: COWLITZ TRIBAL HEALTH SERVICES PROJECT SPONSOR/OWNER: COWLITZ TRIBAL HEATH SERVICES CONTACT: ELIZABETH TAIL 15455 65TH AVENUE SOUTH TUKWILA, WASHINGTON 98188 (206) 721-5170 ARCHITECT: ENVIRONMENTAL WORKS COMMUNITY DESIGN CENTER CONTACT: DONN DEVORE 402 15TH AVENUE EAST SEATTLE, WA 98112 (206) 787-1383 CONTRACTOR: TBD PROJECT DATA T1.1 TITLE SHEET A1.1 SITE PLAN A1.2 SITE DETAILS A2.1 PLAN, DEMO PLAN AND RCP PLAN A3.1 EXTERIOR ELEVATIONS A5.1 INTERIOR ASSEMBLIES AND DETAILS A8.1 DOOR, WINDOW AND FINISH SCHEDULES rE COPY Permit No.. .6.:_..0 3 _k_ Plan roview onpro' m! is subject to errors and Or:713E10r 3. Approval of cons'truciian documents does poi atli:I : 'o the violation of any adopted code or ordinance. Recr.ht of approved Field Copy and conditions is acknowlecj 'i: By: a''-9''-'- Date:.Z°J Ort 2d/ 7 City of Tukwila BUILDING DIVISION VICINITY MAP TOTAL BUILDING AREA: 11,472 SF AREA OF WORK: 582 SF INTERIOR; 860 SF EXTERIOR PLAY AREA ESTIMATED CONSTRUCTION COST: $25,000. TENANT: COWLITZ TRIBAL HEALTH SERVICES PROJECT SPONSOR/OWNER: COWLITZ TRIBAL HEATH SERVICES CONTACT: ELIZABET-I TAIL 15455 65TkI AVENUE SOUTH TUKWILA, WASHING1ON 98188 (206) 721-5170 ARCHITECT: ENVIRONMENTAL WORKS COMMUNITY DESIGN CENTER CONTACT: DONN DEVORE 402 15TH AVENUE EAST SEATTLE, WA 98112 (206) 787-1383 CONTRACTOR: TBD REVISIONS No changes shall ho made to the scope of work withcadt prior approval of T ti!‘vila Building Division. NOTE: i; fviz;i ins wiil require a now plan submittal and may in;,,ude additional plan review fees. I SFR P ^\TE PERMIT REQUIRED FOR: IMochanical l '€lectrical Plumbing Gas Piping Gil:" of Tukwila "'r; DIVISION REVIEWED FOR CODE COMPLIANCE APPROVED DEC 1.6 2016 City of Tukwila BUI! L. RECEIVED C%TY OF TUKWILA DEC 0 8 2016 PERMIT CENTER environmental WORKS Community Design Center 402 15th Avenue East Seattle, Washington 98112 206.329.8300 206.329.5494 fax Cowlitz Tribal Health Services Exterior Modifications and Tenant Improvement 15455 65th Avenue South Tukwila, Washington 98188 UCKER WASHINGTON Title Sheet Code Analysis Date 01 December 2016 Building Permit Revisions Drawn by: DD Checked by (P.M.): DD Checked by (Q.C.): RT Project No. 16-033A T1.1 :: 3 3" DIA GALV STEEL PIPE -10 GA MIN (TYP) WITH 10" DIA CONC FOOTING nl ,VI CLEARANCE FOR DUMPSTER LENGTH 4" THICK 5000 PSI CONC PAD WITH 6X6 WWM OVER 4" MIN COMPACTED 5/8" MINUS GRAVEL ON COMPACTED SUB GRADE PLAN AT TRASH ENCLOSURE A1.1 Scale: 1/4" = 1'-0" O 2 PLAN AT ENCLOSED PLAY AREA 3'x5' WOOD GATE WITH LATCH TO SECURE AND LOCK. MATCH ELEV. 2x4 P.T. NAILER BOTH SIDES PROJECT INFORMATION PROJECT ADDRESS: 15455 65TH AVENUE SOUTH, TUKWILA WA 98188 PARCEL NUMBER: 000320-0004 SITE AREA: 73,701 SF LEGAL DESCRIPTION: GILLIAM W H -DC # 40 BEG NXN C/L RENTON-THREE TREE PT RD & W LN OF SEC TH ELY ALG CIL OF SD RD 4543.03 FT TH N 00-14-00 E 272.03 FT TO TPOB TH S 00-14-00 W TO NWLY MGN VAC MACADAM RD TH S 49-00-00 W 106.38 FT TH N 00-14-00 E 312.55 FT M/L TO S LN OF LOT 17 INTERURBAN ADD TH S 89-09-00 E ALG SD S LN TO SWLY MGN 65TH AVE S TH SELY ALG SD MGN TAP FR WHICH TPOB BEARS S 69-59-00 W TH S 69-59-00 W TO TPOB TGW POR VAC MACADAM RD ADJ TGW POR OF LOT 17 OF INTERUBAN ADD TO SEATTLE DAF - BAAP OF C/L OF RENTON-THREE TREE PT NO 2649 & W LN OF SEC 23-23-04 SD PT BEING ENG STA 135+29.92 FR WCH SW COR OF SD SEC 23 BEARS S 0-11-42 E 2044.06 FT TH S 84-51-48 E 1647.24 FT TH ON A CRV TO RGT HAVING A RAD OF 955.37 FT 360 FT TH S 63-15-48 E 359.18 FT TH ON A CRV TO LFT RAD OF 5729.65 FT 370 FT TH S 66-57-48 E 1162.53 FT TH ON A CRV TO LFT HAVING A RAD OF 716.34 FT 442.40 FT TH N 77-38-42 E 201.68 FT TH LEAVING SD C/L OF SD RD & RUNNING N 00-14-00 E 272.03 FT TH S 00-14-00 W 87.94 FT M/L TO NWLY MGN OF VAC MACADOM RD TH S 49-00-00 W ALG SD NWLY MGN 106.38 FT TH N 00-14-00 E 312.55 FT M/L TO S LN OF LOT 17 IN SD PLAT & TPOB TH CONT N 00-14-00 E 150 FT TH S 88-24-47 E PLW NLY LN OF SD LOT 17 170 FT M/L TO SWLY MGN OF 65TH AVE S TH SELY ALG SD MGN TO SE COR OF SD LOT 17 TH N 89-09-00 W ALG S LN OF LOT 17 TO TPOB LESS RD ZONING INFORMATION ZONING DESIGNATION: 0 BUILDING AREA: 11,473 SF PRESENT AND CURRENT USE: OFFICES -OUTPATIENT MEDICAL CLINIC SETBACKS REQUIRED: FRONT: 25 FEET SIDES: 10 FEET REAR: 10 FEET HEIGHT MAXIMUM: 3 STORIES OR 35 FEET LANDSCAPE REQUIREMENTS: FRONT: 15 FEET SIDES: 5 FEET REAR: 5 FEET OFF-STREET PARKING: 3 PER 1,000 SF FOR OFFICE AND MEDICAL CLINICS 11,473/1,000 x 3 = 35 PARKING SPACES REQUIRED 49 PARKING SPACES PROVIDED 2 ACCESSIBLE SPACES REQUIRED PER IBC TABLE 1106.1 1 VAN STALL REQUIRED PER IBC 1106.5 4X4 PT POST (TYP) WITH CONC FOOTING SEE DETAIL 2/A1.2 1 "x1 "x16 GA CORE BLACK VINYL COATED FENCE MESH AFFIXED TO 4x4 POSTS - 3 SIDES AT INTERIOR FILL AREA WITH 12" DEEP FIBARSYSTEM 300 ENGINEERED WOOD FIBER. PROVIDE FIBARGUARD BLACK BORDER OR SIMILAR TO CONTAIN ENGINEERED WOOD FIBER AT EDGES. EXISTING STRUCTURAL COLUMN TRANSLUCENT COLORED PLEXIGLASS WINDOW ON PT 1x FRAME EXISTING DECK OVERHEAD WOOD GATE WITH LATCH TO SECURE AND LOCK. MATCH ELEV. A1.1 Scale: 1/4" = 1'-0" EXISTING ACCESSIBLE VAN STALL EXISTING ACCESSIBLE STALL w z w 0_ 0 0_ PROPERTY LINE N 0°0'14" E 150.00' S 88°24'47" E 170.00' 1 2 3 4 5 6 7 8 9 10 EXISTING PARKING AREA 11 NO CHANGES 12 13 14 15 16 17 18 19 20 0 0 Z QQ' SITE PLAN Scale: 1" = 30 ft ce w D_ O 0- EXISTING ADA PARKING STALL TO BE RELOCATED NEW PLAY AREA WITH 6-0" HIGH WOOD FENCE REMOVE EXISTING RECYLING AREA FENCE EXISTING TRASH AREA TO BE EXPANDED TO INCLUDE RECYCLING EXISTING PARKING AREA NO CHANGES 1 1 1 1 1 1 1 � 1 1 1 1 1 REVIEWED FOR\1 - CODE COMPLIANCE APPROVED 13. S OUT~CeRTER _ DEC 16_20* - City of Tukwila BUILDING DIVISION RECEIVED r CITY OF TUKWILA DEC 0 8 2016 PERMIT CENTER b1( 033(0 environmental WORKS Community Design Center 402 15th Avenue East Seattle, Washington 98112 206.329.8300 206.329.5494 fax Cowlitz Tribal Health Services Exterior Modifications and Tenant Improvement 15455 65th Avenue South Tukwila, Washington 98188 Site Plan Date 01 December 2016 Building Permit Revisions Drawn by: DD Checked by (P.M.): DD Checked by (Q.C.): RT Project No. 16-033A A1 .1 EQ EQ EQ / EQ ,° - -4 's '- 1.. 2x4 P.T. NAILER, THRU BOLTED TO STEEL a a - . - a _ . - 'a : POST BOTH SIDES (TYP) WITH GALV OR -a ° -a .°-a • - D a - . S.S. FASTENERS. - _ °. • • .. EDGE OF CONCRETE SLAB • ° . a D -a D; -a - 't,.• .6' . •PQ'° - • $, - • a_ -' a •. � a' a a . • . a 2x8 PRESSURE TREATED RUB RAIL - • _ • • • a P '.- CONT @ SIDES AND BACK a P • ; a ° ' -NEW 2x6 CEDAR TRIM TO MATCH CAP . • a .•° , aP AT EACH SIDE OF OPENING. - • ° • EQ EQ o c o) ✓✓/ EQ EQ 7'-6" 7'-0" 7'-6" / / CLEARANCE FOR DUMPSTER LENGTH 4" THICK 5000 PSI CONC PAD WITH 6X6 WWM OVER 4" MIN COMPACTED 5/8" MINUS GRAVEL ON COMPACTED SUB GRADE PLAN AT TRASH ENCLOSURE A1.1 Scale: 1/4" = 1'-0" O 2 PLAN AT ENCLOSED PLAY AREA 3'x5' WOOD GATE WITH LATCH TO SECURE AND LOCK. MATCH ELEV. 2x4 P.T. NAILER BOTH SIDES PROJECT INFORMATION PROJECT ADDRESS: 15455 65TH AVENUE SOUTH, TUKWILA WA 98188 PARCEL NUMBER: 000320-0004 SITE AREA: 73,701 SF LEGAL DESCRIPTION: GILLIAM W H -DC # 40 BEG NXN C/L RENTON-THREE TREE PT RD & W LN OF SEC TH ELY ALG CIL OF SD RD 4543.03 FT TH N 00-14-00 E 272.03 FT TO TPOB TH S 00-14-00 W TO NWLY MGN VAC MACADAM RD TH S 49-00-00 W 106.38 FT TH N 00-14-00 E 312.55 FT M/L TO S LN OF LOT 17 INTERURBAN ADD TH S 89-09-00 E ALG SD S LN TO SWLY MGN 65TH AVE S TH SELY ALG SD MGN TAP FR WHICH TPOB BEARS S 69-59-00 W TH S 69-59-00 W TO TPOB TGW POR VAC MACADAM RD ADJ TGW POR OF LOT 17 OF INTERUBAN ADD TO SEATTLE DAF - BAAP OF C/L OF RENTON-THREE TREE PT NO 2649 & W LN OF SEC 23-23-04 SD PT BEING ENG STA 135+29.92 FR WCH SW COR OF SD SEC 23 BEARS S 0-11-42 E 2044.06 FT TH S 84-51-48 E 1647.24 FT TH ON A CRV TO RGT HAVING A RAD OF 955.37 FT 360 FT TH S 63-15-48 E 359.18 FT TH ON A CRV TO LFT RAD OF 5729.65 FT 370 FT TH S 66-57-48 E 1162.53 FT TH ON A CRV TO LFT HAVING A RAD OF 716.34 FT 442.40 FT TH N 77-38-42 E 201.68 FT TH LEAVING SD C/L OF SD RD & RUNNING N 00-14-00 E 272.03 FT TH S 00-14-00 W 87.94 FT M/L TO NWLY MGN OF VAC MACADOM RD TH S 49-00-00 W ALG SD NWLY MGN 106.38 FT TH N 00-14-00 E 312.55 FT M/L TO S LN OF LOT 17 IN SD PLAT & TPOB TH CONT N 00-14-00 E 150 FT TH S 88-24-47 E PLW NLY LN OF SD LOT 17 170 FT M/L TO SWLY MGN OF 65TH AVE S TH SELY ALG SD MGN TO SE COR OF SD LOT 17 TH N 89-09-00 W ALG S LN OF LOT 17 TO TPOB LESS RD ZONING INFORMATION ZONING DESIGNATION: 0 BUILDING AREA: 11,473 SF PRESENT AND CURRENT USE: OFFICES -OUTPATIENT MEDICAL CLINIC SETBACKS REQUIRED: FRONT: 25 FEET SIDES: 10 FEET REAR: 10 FEET HEIGHT MAXIMUM: 3 STORIES OR 35 FEET LANDSCAPE REQUIREMENTS: FRONT: 15 FEET SIDES: 5 FEET REAR: 5 FEET OFF-STREET PARKING: 3 PER 1,000 SF FOR OFFICE AND MEDICAL CLINICS 11,473/1,000 x 3 = 35 PARKING SPACES REQUIRED 49 PARKING SPACES PROVIDED 2 ACCESSIBLE SPACES REQUIRED PER IBC TABLE 1106.1 1 VAN STALL REQUIRED PER IBC 1106.5 4X4 PT POST (TYP) WITH CONC FOOTING SEE DETAIL 2/A1.2 1 "x1 "x16 GA CORE BLACK VINYL COATED FENCE MESH AFFIXED TO 4x4 POSTS - 3 SIDES AT INTERIOR FILL AREA WITH 12" DEEP FIBARSYSTEM 300 ENGINEERED WOOD FIBER. PROVIDE FIBARGUARD BLACK BORDER OR SIMILAR TO CONTAIN ENGINEERED WOOD FIBER AT EDGES. EXISTING STRUCTURAL COLUMN TRANSLUCENT COLORED PLEXIGLASS WINDOW ON PT 1x FRAME EXISTING DECK OVERHEAD WOOD GATE WITH LATCH TO SECURE AND LOCK. MATCH ELEV. A1.1 Scale: 1/4" = 1'-0" EXISTING ACCESSIBLE VAN STALL EXISTING ACCESSIBLE STALL w z w 0_ 0 0_ PROPERTY LINE N 0°0'14" E 150.00' S 88°24'47" E 170.00' 1 2 3 4 5 6 7 8 9 10 EXISTING PARKING AREA 11 NO CHANGES 12 13 14 15 16 17 18 19 20 0 0 Z QQ' SITE PLAN Scale: 1" = 30 ft ce w D_ O 0- EXISTING ADA PARKING STALL TO BE RELOCATED NEW PLAY AREA WITH 6-0" HIGH WOOD FENCE REMOVE EXISTING RECYLING AREA FENCE EXISTING TRASH AREA TO BE EXPANDED TO INCLUDE RECYCLING EXISTING PARKING AREA NO CHANGES 1 1 1 1 1 1 1 � 1 1 1 1 1 REVIEWED FOR\1 - CODE COMPLIANCE APPROVED 13. S OUT~CeRTER _ DEC 16_20* - City of Tukwila BUILDING DIVISION RECEIVED r CITY OF TUKWILA DEC 0 8 2016 PERMIT CENTER b1( 033(0 environmental WORKS Community Design Center 402 15th Avenue East Seattle, Washington 98112 206.329.8300 206.329.5494 fax Cowlitz Tribal Health Services Exterior Modifications and Tenant Improvement 15455 65th Avenue South Tukwila, Washington 98188 Site Plan Date 01 December 2016 Building Permit Revisions Drawn by: DD Checked by (P.M.): DD Checked by (Q.C.): RT Project No. 16-033A A1 .1 OVERLAP EVERY OTHER BOARD PAIR @ 90 DEG. CORNERS, TYP. TRANSLUCENT PLEXIGLASS WINDOW IN PT FRAME WITH lx CEDAR BLOCKING. 1X8 & 1X4 TIGHT KNOT CEDAR BOARDS, TYP. 491 .2 1'-6" ALIGN ALIGN EQ EQ ELEVATION AND SECTION - PLAY AREA Scale: 1" = 1'-0" OVERLAP EVERY OTHER BOARD PAIR @ 90 DEG. CORNERS, TYP. 1X8 & 1X4 TIGHT KNOT CEDAR BOARDS, TYP. c N ELEVATION 2X TK CEDAR CAP SLOPED -� 1►A , lr���������4 :i�iiiii�����4 i�. 1 ► .14 TYP. NEW TIGHT KNOT CEDAR BOARDS, SEE ELEVATION. 2x6 PT FRAME. TRANSLUCENT PLEXIGLASS WINDOW IN PT FRAME WITH 1x CEDAR BLOCKING. 4 1"x1"x16 GA CORE BLACK VINYL COATED FENCE MESH. PROVIDE OPENING AT PLEXIGLASS WINDOW. �i► 4x4 PT POST mull WOOD FIBER SECURED BORDER. BREAK AT GATE AREAS. 11 1 1 1 1 1111 —1111 IIII III 2X TK CEDAR CAP, SLOPED TYP. ENGINEERED WOOD FIBER TO 12" DEEP. FIBARSYSTEM 300 OR SIM. EXISTING CONCRETE SLAB SIMPSON CBSQ44-SDS2 18"x18"x12" CONCRETE FOOTING W/(2) #4'S EA WAY, TYP NEW TIGHT KNOT CEDAR BOARDS, SEE ELEVATION. NEW P.T. 2X8 RUB RAIL @ INTERIOR, THREE LEVELS. EXISTING CONCRETE SLAB. REPLACE WITH NEW SLAB OR APPEND TO MEET NEW SIZE OF ENCLOSURE. ELEVATION ELEVATION AND SECTION - TRASH ENCLOSURE Scale: 1" = 1'-0" PIPE COLUMN BEYOND. EMBED IN NEW FOOTING 1'-6" MIN. 10" DIAMETER CONCRETE FOOTING SECTION REVIEWED FOR CODE COMPLIANCE APPROVED DEC 16 2016 City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKW LA DEC 0 8 2016 PERMIT CENTER SECTION environmental WORKS Community Design Center 402 15th Avenue East Seattle, Washington 98112 206.329.8300 206.329.5494 fax Cowlitz Tribal Health Services Exterior Modifications and Tenant Improvement 15455 65th Avenue South Tukwila, Washington 98188 Site Plan Details Date 01 December 2016 Building Permit Revisions Drawn by: DD Checked by (P.M.): DD Checked by (Q.C.): RT b*%033� A1.2 Project No. 16-033A -1— r -, — r T '" 1— r —1— r 1— r 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 —1-1—LJ-1-1J—L1-1—LJ—I—IJ—L1 PARTIAL LEVEL 2 -EXISTING DECK DEMO EXISTING STAIR PREVIOUSLY INSTALLED UNDER JUNE 2008 PERMIT D07-374. INFILL RAILING SHALL BE A MINIMUM OF 42" AFF AND SHALL RESIST A LINEAR LOAD OF 50 LBS PER LF AND A CONCENTRATED LOAD OF 200 LBS PER IBC 1607.8. GUARDS SHALL BE DESIGNED TO NOT PERMIT THE PASSAGE OF A SPHERE WITH A DIA OF 4" PER 1012.10.1 NO WORK TO BE DONE IN THIS AREA ,A2. 1} Scale: 118" = 1'-0" )( 2 PARTIAL BASEMENT REFLECTED CEILING PLAN NEW ACOUSTIC CEILING TILE CEILING AT 8'-0" AFF MIN. NEW PRE-ENGINEERED FABRIC CANOPY NO CHANGES TO EXISTING GWB CEILING, TYP. REPAIR AS NECESSARY FROM ANY CONSTRUCTION DAMAGE. TROFFER 2x4 LED CEILING LIGHT FIXTURE. METALUX 14CZ-LD4-35-UNV-L835-CD1-U (36.2 WATTS) SUPPLY REGISTER - CONNECT INTO EXISTING MECH SYSTEM AND REBALANCE. RETURN REGISTER -CONNECT INTO EXISTING MECH SYSTEM. NEW WALL [3 1/2" WOOD STUDS FULL HEIGHT TO GWB ABOVE AT 24" O.C. WITH 1/2" GWB EACH SIDE - NO FIRE RATING] EXISTING WALL NO WORK TO BE DONE IN THIS AREA A2.1 Scale: 1/8" = 1'-0" ° '1 1 1 1 I I 1 1 I 1 I .i 1 1 1 1 1. 1 1 1 I p p L -L1J- [N] RECEPTIO [N] CHILD SUPERVISED SPACE N 121 ®r' 20A l [E] CORR. / /,, % �/, ,,/ , : / // ;�[E] MEETING/ EXISTING tea,INTIO [N] SERVER P;frAfr //A,r A/74- —i€isoQ r i/fr/4-°"/ /3,1r."1 dip° "" le/115 II I //:// /, /// israciirAmarm N BASEMENT PLAN Scale: 1/8" =1'-0" EXISTING STAIR TO BE DEMOLISHED EXISTING COLUMN TO BE DEMOLISHED, TYP. EXISTING COLUMN TO REMAIN, TYP EDGE OF DECK ABOVE REPLACE EXISTING METAL DOOR WITH GLAZED WINDOWS TO MATCH BUILDING STANDARD. U -FACTOR 0.38 OR BETTER AND A SHGC OF 0.64 OR BETTER. REPLACE EXISTING METAL DOOR WITH FULLY GLAZED DOOR. EXTERIOR DOOR SHALL HAVE A U -FACTOR OF 0.60 OR BETTER WITH AN SHGC OF 0.48 OR BETTER. NEW PRE-ENGINEERED FABRIC CANOPY OVERHEAD EXISTING FIXTURES TO REMAIN. NO CHANGES TO TOILETS, LAVATORIES OR GRAB BAR LOCATIONS. NEW WASHER AND DRYER. WASHER TO HAVE SANITIZING CYCLE. DRYER SHALL VENT TO OUTSIDE. VENT SHALL BE NO CLOSER THAN 3'-0" TO OPERABLE OPENING. PROVIDE POWER TO MEET WASHER/DRYER REQUIREMENTS. REMOVE JANITOR SINK. 0 NEW WALL [3 1/2" WOOD STUDS FULL HEIGHT TO GWB ABOVE AT 24" O.C. WITH 1/2" GWB EACH SIDE - NO FIRE RATING] EXISTING WALL NO WORK TO BE DONE IN THIS AREA 8 16 REVIEWED FOR CODE COMPLIANCE APPROVED DEC 1 2016 City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA DEC 0 8 2016 PERMIT CENTER bUo'O33& Demo Plan Floor Plan Reflected Ceiling Plan A2.1 DEMOLISH EXISTING STAIR AND LANDING. INFILL DECK RAILING PER PLANS. NEW GLAZING IN EXISTING DOOR OPENING. REPLACE ANY DAMAGED BRICK VENEER DURING REMOVAL. MATCH TRIM OF EXISTING WINDOWS ADJACENT. OUTLINE OF FENCED IN PLAY AREA. SEE SHEET A1.1. NEW PRE-ENGINEERED FABRIC CANOPY. —mer Z�Z'iTr..Z--zWWI -Z-ZZZ1�iZ--yZ�LZZ__�-W_ Wm INIWWWWIIMIWNMENNIWIWIW,W.- ---_ =Z =Z ZZZZ���Z_ZZ- � -• =s==zz=azi=WE .M.011W NWIWWIMINIWIMMIIW MEM =?yz�MINIIMIEMOMMOMIIIIMOJMIERWI BMW. ,11.. -- NW ��—ZZZ—ZZZZZZZ Z-Z�� ��ZZZ=_ Z�--=-------1--L ZZZ---ZZZ IWE WWI W. WIWWWWwl mei---------- 2 West Elevation ti I 1 I HE A3.1 Scale: 1/8" =11-0" ----------:...... 1......15 1.. ________ __ _ _ _________ _ ____ 2 1. 7. Mr zz� ZWW� Z=====_�=_______ —•W WW WWWWIIWIWWWWWWWWW INIMINwWwWwWw WW MINIUM MNIWNWIIIWWWWWWI WW 3�ZWm y�=sZZZZ=Z-WWWWWWWWWWWWI zzWI ZZZZWWWWWWWW =�z—z—z=====�Zz== =ZZZ-z ==-flaw z =___ =ZZ==— WWI WWWWWWW --ZZZ= =_--- ______� =____' ____M '�WOON IMI z�ZZZZZ—=---Z�--------------Zy=== WM ==_--WIWWI NM MN NM= MINIM 11 �.a-- z --""L-- --- IMM-WINIC .ZMIWININTRIW_� Z—_�ZZZZZ�-��� _W_��_—�M__ME_IM__�-=——_jZ=�__—�WWNW—��—MWM ��___WM_�__MNWM�_��_—�=—_Z�=�=�—WM—WWWWWIIMIN ���__ MW-- NW WINIIWIIIIWI •••••1•W ce'. — INIW__��Z_Z`-_==_=_=_====_=ZINW_=_=_=__=_=_=_=_=_=_==__WWWWWWWW =y_?y'r=?ZWZ=�==_=__Z_?_==_=_=_==WWWW_==_=__=Z=__=__=_=__W_=_=_=_=_=_ =_=Z== Zy ~ NEMIzz— WINWIEMMM IMMIMMIMIM .=______ z.... — =__====z =ZZZ—?.iZ-�Z Z —_—�__=____====—z =_____________-- REMOVE STAIR AND LANDING PREVIOUSLY ADDED UNDER JUNE 2008 PERMIT D07-374. NEW PRE-ENGINEERED FABRIC CANOPY. REPLACE EXISTING MERCURY LIGHT FIXTURE WITH LED OUTDOOR WALL PACK DOWNLIGHT. FIXTURE AND CANOPY COLOR/DESIGN TO BE CHOSEN BY ARCHITECT/OWNER. NEW GLAZED DOOR IN EXISTING FRAME. OUTLINE OF NEW FENCED PLAY AREA. SEE SHEET A1.1. EXISTING DOOR. NO CHANGES. 1 ,--44111w 1 4 771 , 1 111 EMI 1 // REVIEWED FOR CODE COMPLIANCE APPROVED DEC 1 X16 City of Tukwila BUILDINQ(VISION environmental WORKS Community Design Center 402 15th Avenue East Seattle, Washington 98112 206.329.8300 206.329.5494 fax Cowlitz Tribal Health Services Exterior Modifications and Tenant Improvement 15455 65th Avenue South Tukwila, Washington 98188 Exterior Elevations Date 01 December 2016 Building Permit Revisions RECEIVED CITY OF TUKWILA South Elevation Scale: 1/8" = 1'-0" DEC 0 8 2016 Drawn by: DD PERMIT CENTER_ bt 033& 17 Checked by (P.M.): DD Checked by (Q.C.): RT Project No. 16-033A A3.1 5 SCREW OPTIONAL UNATTACHED WALL iSCREW TIGHTENED THROUGH MAIN RUNNER WEB RESTRICTING SEPARATION FROM WALL MOLDING = =I = = = I=1 ATTACHED WALL BERC CLIP - GRID A5.1 NTS #12 GA SPLAY BRACED WIRES MAIN RUNNER A5.1 STRUCT COMPRESSION STRUT #12 GA SPLAY BRACED WIRES COMPRESSION PIPE STRUT SIZE SCHEDULE (BASED ON UR > 200) SIZE MAX. HEIGHT 1/2" x 22 GA, 3'-0" 3/4" x 22 GA 4'4' 1" x 20 GA 6%0" 1 1/4" x 20 GA 7'-O" I 1/2' x 20 GA 6-6" 2" x 20 G A 11-6' 2 1/2" x 18 GA 14'.--6" 3" x )8 GA IT -3" 3 1/2" x 16 GA 230-3" COMPRESSION STRUT NTS CROSS -TEE (REFER TO SPECIFICATIONS) 12 GA HANGER WIRE AT 2-0' 0..C„ TYPICAL • BERC 2 SEISMIC CLIP REFER TO DETAIL MAIN RUNNER OR CROSS -TE +RCP REFER TO V MIN — " ACOUSTICAL CEILING TILE AS SCHEDULED SHADOW MOLDING, WPICAL PARTITION AS SCHEDULE!) n3 CEILING TO WALL DETAIL i°!•"_1} NTS V MEN CLR CROSS OR MAIN RUNNER iff 8" R EF LECTE 12'-0" OC 4'-0" MAX. • D CEILING PLA NOTE TIE THE ADJACENT WALLS. N VERTICAL COMPRESSION STRUT AT 12'4T OC EA WAY WIII-IFIRST POINT TO BE WITHIN 6'-O" FROM EACH WALL FASTENED TO MAIN RUNNER & STRUCTURE ABOVE. 12 -GA VERTICAL HANGER IMRE AT 2'-O" EA WAY WITH MIN 3 TIGHT TURNS IN 1-112' BOTH ENDS OF WIRE , 12 -GA BRACING WIRE WITH MIN 4 TIGHT TURNS IN 1Iz" BOTH ENDS OF VIRE (TYPICAL) CROSS RUNNERS MAIN RUNNERS CEILING MAIN & CROSS RUNNER NOTE: INSTALL CEILING GRID USING #12 GA SPLAY WIRE HANGERS (1): 45 DEGREES, 90 DEGREES TO EA OTHER (4 WiRES) BEGINNING 4'4)" FROM STARTING POINT OF GRID AND TILE LAYOUT AND IN BOTH DIRECTIONS AT 17-0" THEREAFTER_ NOTE 1. T MAX FROM BRACING WIRES TO GROSS RUNNERS 2. MAX 6'-O" GAP FROM SUSPENDED AND GYPSUM BOARD CEIU NGS 3_ SOFFITS - IF GREATER THAN 6'-O", THEN LATERAL DESIGN REQUIRED ARMSTRONG PRELUDE XL 15/ 16!' ICC #ESR -13013, LARR #2.5032 ASTM c635,. HEAVY DUTY 2 ACOUSTICAL CEILING TILE SUSPENSION A5.1 1 NTS A5.1 1/2" LAYER OF GWB 2x6 STUDS @ 16" 0.C. 1/2" LAYER OF GWB TYPICAL NEW WALL Scale: 1 1/2" = REVIEwEra FOR CODE COMPLIANCE APPROVED DEC 1 Thnt City of Tukwila BUILDING DIVISION b1(9 -o33 RECEIVED CITY OF TUKWILA DEC 08 2016 PERMIT CENTER NO FIRE RATING REQUIRED environmental WORKS Community Design Center 402 15th Avenue East Seattle, Washington 98112 206.329.8300 206.329.5494 fax Cowlitz Tribal Health Services Exterior Modifications and Tenant Improvement 15455 65th Avenue South Tukwila, Washington 98188 Assemblies and Details Date 07 June 2016 Building Permit Revisions Drawn by: DD Checked by (P.M.): DD Checked by (Q.C.): RT Project No. 16-033A A5.1 DOOR SCHEDULE DOOR ROOM SIZE c., CEILING ENERGY CODE TYPE DOOR MATERIAL FRAME DETAIL NUMBER NAME WIDTH r ,/ NUMBER NAME WIDTH SHGC HEIGHT MATERIAL THICK OPERATION HEAD MATERIAL FINISH MATERIAL FINISH HEAD JAMB THRESHOLD HW SET 6'6" GLAZING REMARKS 120A RECEPTION MATCH (E) 4'0" - 7'0" 1 3/4" A METAL PAINT EXISTING PAINT - - - GWB 1 SG MAX 1/2" THRESHOLD 120B RECEPTION HOT WATER 3'0" ENHANCED URETHANE 7'0" 1 3/4" B MATCH (E) PAINT MATCH (E) PAINT - - - 2 SG 121 CHILD SUPERVISED SPACE 3'0" 7'0" 1 3/4" B MATCH (E) PAINT MATCH (E) PAINT - - - 2 SG 122 HOT WATER 3'0" 7'0" 1 3/4" C MATCH (E) PAINT MATCH (E) PAINT - - - 3 - THE FORCE FOR PUSHING OR PULLING OPEN INTERIOR SWINGING EGRESS DOORS SHALL NOT EXCEED 5 POUNDS. OTHER DOORS, THE DOOR LATCH SHALL RELEASE WHEN SUBJECTED TO A 15 POUND FORCE AND SHALL BE SET IN MOTION WHEN SUBJECTED TO A 30 POUND FORCE. THE DOOR SHALL SWING TO A FULL -OPEN POSITION WHEN SUBJECTED TO A 15 POUND FORCE. ALL DOOR LOCKETS/LATCHSETS TO BE LEVERS FOR ACCESSIBLE ACCESS PER ICC A117.1. LOCKSETS AND LATCHSETS SHALL BE MOUNTED A MIN OF 34" TO A MAXIMUM OF 48" ABOVE FLOOR FINISH. HARDWARE FINISH AND MAVUFACTURER SHALL MATCH BUILDING STANDARD. LOCK SETS SHALL BE KEYED TO BUILDING MASTER. EXTERIOR DOOR SHALL HAVE A U -FACTOR OF 0.60 OR BETTER WITH AN SHGC OF 0.48 OR BETTER. HARDWARE (HW) SET 1 -CLOSER - WEATHERSTRIPPING/GASKET -THRESHOLD - DEADBOLT - CLASSROOM FUNCTION LOCK - ADD ALTERNATE - CARDKEY ACCESS HARDWARE SET 2 -CLOSER - CLASSROOM FUNCTION LOCK HARDWARE SET 3 - STORAGE FUNCTION LOCK WINDOW SCHEDULE PROVIDE KICKPLATE 10" MIN AT BOTTOM RAIL, TYP SG (--- PROVIDE LOUVERED VENT DOOR TYPE ELEVATIONS A B C WINDOW ROOM SIZE c., CEILING ENERGY CODE z FRAME MATERIAL DETAIL MATERIAL NUMBER NAME WIDTH r ,/ HEIGHT 114 U -VALUE SHGC ENHANCED URETHANE MATERIAL FINISH OPERATION HEAD JAMB SILL REMARKS 01 CHILD SUPERVISED SPACE - 6'0" EXISTING 6'6" 0.38 EXISTING 0.64 MATCH (E) MATCH (E) FIXED - - - MATCH BUILDING STANDARD WINDOW UNITS SHALL BE NFRC LABELED WITH THE REQUIRED ENERGY PERFORMANCE RATINGS OF THE 2015 WASHNGTON STATE ENERGY CODE. WINDOW ELEVATION FINISH SCHEDULE REVIEWED FOR CODE COMPLIANCE APPROVED DEC 1 2016 City or Tukwila BUILDIN _DIVISION o 33 b ROOM FLOOR BASE c., CEILING z , x MATERIAL FINISH MATERIAL -•-:\ FINISH ///, / r ,/ COMMENTS 114 SERVER VINYL SHT WINDOW ELEVATION FINISH SCHEDULE REVIEWED FOR CODE COMPLIANCE APPROVED DEC 1 2016 City or Tukwila BUILDIN _DIVISION o 33 b ROOM FLOOR BASE WALL CEILING NUMBER NAME MATERIAL FINISH MATERIAL MATERIAL FINISH MATERIAL FINISH COMMENTS 114 SERVER VINYL SHT ENHANCED URETHANE RUBBER GWB PAINT ACT - 117 JANITOR EXISTING - EXISTING EXISTING EXISTING EXISTING EXISTING 120 RECEPTION CARPET TILE - RUBBER GWB PAINT ACT - 121 CHILD SUPERVISED SPACE LINOLEUM WAX RUBBER GWB PAINT ACT - 122 HOT WATER VINYL SHT ENHANCED URETHANE RUBBER GWB PAINT EXISTING ALL INTERIOR WALL AND CEILING FINISHES SHALL BE CLASSIFIED AS A CLASS C OR BETTER. ALL INTERIOR FLOOR FINISHES SHALL BE CLASS II. ACT = ACOUSTICAL CEILING -ILE GWB = GYPSUM WALL BOARD. MATCH EXISTING TEXTURE. environmental WORKS Community Design Center 402 15th Avenue East Seattle, Washington 98112 206.329.8300 206.329.5494 fax Cowlitz Tribal Health Services Exterior Modifications and Tenant Improvement 15455 65th Avenue South Tukwila, Washington 98188 Door, Window, and Finish Schedules Date 01 December 2016 Building Permit Revisions Drawn by: DD RECEIVED CITY OF TUKWILA DEC 0 8 2016 Checked by (P.M.): DD Checked by (Q.C.): RT PERMIT CENTER Project No. 16-033A A8.1