Loading...
HomeMy WebLinkAboutPermit D16-0349 - SEATTLE METROPOLITAN CREDIT UNION - BUILD OUTSEATTLE METROPOPLITAN CREDIT UNION 17250 SOUTHCENTER PKWY SUITE 132 Dl 6=0349 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-438-9350 Web site: http://www.TukwilaWA.Rov Parcel No: 7888920020 DEVELOPMENT PERMIT Permit Number: Address: 17250 SOUTHCENTER PKWY Unit132 Issue Date: Permit Expires On Project Name: SEATTLE METROPOLITAN CREDIT UNION Owner: Name: WIG PROPERTIES LLC -SS Address: 4811 134TH PL SE, BELLEVUE, WA, 98006 Contact Person: Name: TERESA PORTMAN Address: 909 112TH AVE NE, STE 206, BELLEVUE, WA, 98004 Contractor: Name: D P INC GENERAL CONTRACTORS Address: 19936 BALLINGER WAY NE, SEATTLE, WA, 9815S License No: DPINCGCO66BU Lender: Name: SEATTLE METROPOLITAN CREDIT UNION Address: 17250 SOUTHCENTER PKWY, TUKWILA, WA, 98188 DESCRIPTION OF WORK: D16-0349 3/2/2017 8/29/2017 Phone: (425) 641-9200 Phone: (206) 361-2989 Expiration Date: 1/31/2018 BUILD OUT OF EXISTING SPACE IN RETAIL BUILDING TO ACCOMMODATE NEW CREDIT UNION, INCLUDING MEETING ROOMS, STAFF BREAK AREA AND WORK ROOM. EXISTING ADA COMPLIANT RESTROOMS WILL BE UPGRADED WITH NEW SINKS, CASEWORK, AND PARTITIONS. Project Valuation: $595,000.00 Type of Fire Protection: Sprinklers: YES Fire Alarm: YES Type of Construction: Electrical Service Provided by: TUKWILA Fees Collected: $9,475.72 Occupancy per IBC: B WaterDistrict: TUKWILA SewerDistrict: TUKWILA I Current Codes adopted by the City of Tukwila: International Building Code Edition: International Residential Code Edition: International Mechanical Code Edition: Uniform Plumbing Code Edition: International Fuel Gas Code: Public Works Activities: Chan n e I izati on/Stri ping: Curb Cut/Access/Sidewalk: Fire Loop Hydrant: Flood Control Zone: Hauling/Oversize Load: Land Altering: Landscape Irrigation: Sanitary Side Sewer: Sewer Main Extension: Storm Drainage: Street Use: Water Main Extension: 2015 National Electrical Code: 2014 2015 WA Cities Electrical Code: 2014 2015 WAC 296-46B: 2014 2015 WA State Energy Code: 2015 2015 Volumes: Cut: 0 Fill: 0 Number: 0 Water Meter: No Permit Center Authorized Signature- U .;n !?7:4 Date: I hearby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this development permit and agree to the qchditions attached to this permit. Signature: L Print Name: Date: This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 4: The total number of fire extinguishers required for a light hazard occupancy with Class A fire hazards is calculated at one extinguisher for each 3,000 sq. ft. of area. The extinguisher(s) should be of the "all purpose" (2A, 10 B:C) dry chemical type. The travel distance to any extinguisher must be 75' or less. (IFC 906.3) (NFPA 10, 5.4) 1: Portable fire extinguishers, not housed in cabinets, shall be installed on the hangers or brackets supplied. Hangers or brackets shall be securely anchored to the mounting surface in accordance with the manufacturer's installation instructions. Portable fire extinguishers having a gross weight not exceeding 40 pounds (18 kg) shall be installed so that its top is not more than 5 feet (1524 mm) above the floor. Hand- held portable fire extinguishers having a gross weight exceeding 40 pounds (18 kg) shall be installed so that its top is not more than 3.5 feet (1067 mm) above the floor. The clearance between the floor and the bottom of the installed hand-held extinguishers shall not be less than 4 inches (102 mm). (IFC 906.7 and IFC 906.9) 2: Extinguishers shall be located in conspicuous locations where they will be readily accessible and immediately available for use. These locations shall be along normal paths of travel, unless the fire code official determines that the hazard posed indicates the need for placement away from normal paths of travel. (IFC 906.5) 3: Fire extinguishers require monthly and yearly inspections. They must have a tag or label securely attached that indicates the month and year that the inspection was performed and shall identify the company or person performing the service. Every six years stored pressure extinguishers shall be emptied and subjected to the applicable recharge procedures. If the required monthly and yearly inspections of the fire extinguisher(s) are not accomplished or the inspection tag is not completed, a reputable fire extinguisher service company will be required to conduct these required surveys. (NFPA 10, 7.2, 7.3) 5: Maintain fire extinguisher coverage throughout. 6: Egress doors shall be readily openable from the egress side without the use of a key or special knowledge or effort. (IFC 1008.1.8.3 subsection 2.2) 7: Dead bolts are not allowed on auxiliary exit doors unless the dead bolt is automatically retracted when the door handle is engaged from inside the tenant space. (IFC Chapter 10) 8: Exit hardware and marking shall meet the requirements of the International Fire Code. (IFC Chapter 10) 9: Door handles, pulls, latches, locks and other operating devices on doors required to be accessible by Chapter 11 of the International Building Code shall not require tight grasping, tight pinching or twisting of the wrist to operate. (IFC 1008.1.9.1) 10: Exits and exit access doors shall be marked by an approved exit sign readily visible from any direction of egress travel. Access to exits shall be marked by readily visible exit signs in cases where the exit or the path of egress travel is not immediately visible to the occupants. Exit sign placement shall be such that no point in an exit access corridor is more than 100 feet (30,480 mm) or the listed viewing distance for the sign, whichever is less, from the nearest visible exit sign. (IFC 1011.1) 11: Every exit sign and directional exit sign shall have plainly legible letters not less than 6 inches (152 mm) high with the principal strokes of the letters not less than 0.75 inch (19.1 mm) wide. The word "EXIT" shall have letters having a width not less than 2 inches (51 mm) wide except the letter "I", and the minimum spacing between letters shall not be less than 0.375 inch (9.5 mm). Signs larger than the minimum established in section 1011.5.1 of the International Fire Code shall have letter widths, strokes and spacing in proportion to their height. The word "EXIT" shall be in high contrast with the background and shall be clearly discernible when the exit sign illumination means is or is not energized. If an arrow is provided as part of the exit sign, the construction shall be such that the arrow direction cannot be readily changed. (IFC 1011.6) 12: Aisles and aisle access ways serving as a portion of the exit access in the means of egress system shall comply with the requirements of this section. Aisles or aisle access ways shall be provided from all occupied portions of the exit access which contain seats, tables, furnishings, displays and similar fixtures or equipment. The required width of aisles shall be unobstructed. (IFC 1017.1) 13: Exit signs shall be illuminated at all times. To ensure continued illumination for a duration of not less than 90 minutes in case of primary power loss, the sign illumination means shall be connected to an emergency power system provided from storage batteries, unit equipment or on-site generator. (IFC 1011.6.3) 14: Emergency lighting facilities shall be arranged to provide initial illumination that is at least an average of 1 foot-candle (11 lux) and a minimum at any point of 0.1 foot-candle (1 lux) measured along the path of egress at floor level. Illumination levels shall be permitted to decline to 0.6 foot-candle (6 lux) average and a minimum at any point of 0.06 foot-candle (0.6 lux) at the end of the emergency lighting time duration. A maximum-to-minimurn illumination uniformity ratio of 40 to 1 shall not be exceeded. (IFC 1006.3.1) 18: Fire protection systems shall be maintained in accordance with the original installation standards for that system. Required systems shall be extended, altered or augmented as necessary to maintain and continue protection whenever the building is altered, remodeled or added to. Alterations to fire protection systems shall be done in accordance with applicable standards. (IFC 901.4) 16: Sprinklers shall be installed under fixed obstructions over 4 feet (1.2 m) wide. (NFPA 13-8.6.5.3.3) 15: All new sprinkler systems and all modifications to existing sprinkler systems shall have fire department review and approval of drawings prior to installation or modification. New sprinkler systems and all modifications to sprinkler systems involving more than 50 heads shall have the written approval of Factory Mutual or any fire protection engineer licensed by the State of Washington and approved by the Fire Marshal prior to submittal to the Tukwila Fire Prevention Bureau. No sprinkler work shall commence without approved drawings. (City Ordinance No. 2436). 19: A fire alarm system is required for this project. The fire alarm system shall meet the requirements of N.F.P.A. 72 and City Ordinance #2437. 21: Maintain fire alarm system audible/visual notification. Addition/relocation of walls or partitions may require relocation and/or addition of audible/visual notification devices. (City Ordinance #2437) 20: All new fire alarm systems or modifications to existing systems shall have the written approval of The Tukwila Fire Prevention Bureau. No work shall commence until a fire department permit has been obtained. (City Ordinance #2437) (IFC 901.2) 22: An electrical permit from the City of Tukwila Building Department Permit Center (206-431-3670) is required for this project. 23: All electrical work and equipment shall conform strictly to the standards of the National Electrical Code. (NFPA 70) 24: The maximum flame spread class of finish materials used on interior walls and ceilings shall not exceed that set forth in Table No. 803.9 of the International Building Code. 25: In order to provide you with the fastest police and fire protection under emergency conditions, please post your suite, room or apartment number in a conspicuous place near the main entry door. 17: Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (City Ordinances #2436 and #2437) 26: Any overlooked hazardous condition and/or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. 27: These plans were reviewed by Inspector 511. If you have any questions, please call Tukwila Fire Prevention Bureau at (206)575-4407. 28: 'BUILDING PERMIT CONDITIONS' 29: Work shall be installed in accordance with the approved construction documents, and any changes made during construction that are not in accordance with the approved construction documents shall be resubmitted for approval. 30: All permits, inspection record card and approved construction documents shall be kept at the site of work and shall be open to inspection by the Building Inspector until final inspection approval is granted. 31: All construction shall be done in conformance with the Washington State Building Code and the Washington State Energy Code. 32: There shall be no occupancy of a building until final inspection has been completed and approved by Tukwila building inspector. No exception. 33: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of this requirement. 34: Every occupied space other than enclosed parking garages and buildings used for repair of automobiles shall be ventilated in accordance with the applicable provisions of the International Mechanical Code. 35: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206-431-3670). 36: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center. 37: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 38: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431-3670). PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 1700 BUILDING FINAL" 0611 EMERGENCY LIGHTING 1400 FIRE FINAL 0409 FRAMING 0606 GLAZING LATH & GYPSUM 0406 SUSPENDED CEILING .0 CITY OF TUKh -.A Comm unity Development Department Public Works Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 httl2://www.TukwilaWA.F4ov Building Perwit No. Project No. a i . - Date Application Accepted: 'Vk V Date Application Expires: (For office us only) CONSTRUCTION PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. "Please Print" SITE LOCATION King Co Assessor's Tax No.: 788892-0020 Site Address: 17250 Southcenter BXd Suite Number: Floor: Tenant Name: Seattle Metropolitan Credit Union New Tenant: V ..... Yes E1..No PROPERTY OWNER Name: Wig Properties LLC Address: 4811 134th Place SE City: Bellevue State: WA z CONTACT PERSON — person receiving all project conununication Name: Teresa Portman Address: 909 112th Avenue NE Suite 206 City: Bellevue State: WA Zip: 98004 Phone: (260) 641-9200 Fax: Email: teresap@jpcarchitects.com GENERAL CONTRACTOR INFORMATION Company Name: DP Incorporated Address: 19936 Ballinger Way NTE City: Seattle State: WA Zip: 98155 Phone: (206) 361-2989 Fax: Contr Reg No.: DPINCGCO66BU Exp Date: 01/31/2018 Tukwila Business License No.: H:\Applicationskfomis-Applications On Line\2011 Applications\Pcffnit Application Revised - 8-9-1 I.docx Revised: August 2011 bh ARCHITECT OF RECORD Company Name: JPC Architects PLLC Architect Name: Teresa Portman Address: 909 112th Ave NE Suite 206 C't)' Bellevue State: WA Zip: 98004 Phone: (206) 641-9200 Fax: Email: teresap@jpcarchitects.com ENGINEER OF RECORD Company Name: n/a Engineer Name: Address: City: State: Zip: Phone: Fax: Email: LENDER/BOND ISSUED (required for projects $5,000 or greater per RCW 19.27.095) Name: 4eL;r T:�It-�>ffZ5 Address: a4— City: State: Zip: Page I of 4 MING PERmrr INFORMATIO!-2%431-3670 Valuation of Project (contractor's bid price): $ 595,000 Existing Building Valuation: $ Describe the scope of work (please provide detailed information): Build out of existing space in retail building to accommodate new credit union, including meeting rooms, staff break area, and work room. Existing ADA compliant restrooms will be upgraded with new sinks, casework, and partitions. New finishes throughout. Will there be new rack storage? El ..... Yes V.. No If yes, a separate permit and plan submittal will be required. IProvide Ali Building Areas In Square Footage Below PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq 11): Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact: Handicap: Will there be a change in use? 0 ....... Yes ....... No If "yes", explain: Previously a restaurant FIRE PROTECTION/HAZARDOUS MATERIALS: Z ....... Sprinklers JZ ....... Automatic Fire Alarm El ....... None E] ....... Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? El ....... Yes Z ....... No If "yes, attach list ofmaterials and storage locations on a separate 8-112 " x I I "paper including quantities and Material Safety Data Sheets. SEPTIC SYSTEM F1 ....... On-site Septic System — For on-site septic system, provide 2 copies of a current septic design approved by King County Health Department. li:\Applications\Forms-Applications On Linc\201 I ApplicationsTermit Application Revised - 8-9-1 I.docx Revised: August 2011 Page 2 of 4 bh Existing Interior Remodel Addition to Existing Structure New Type of Colastruction per IBC Type of Occupancy per IBC I" Floor 3,697 3,697 0 0 Type I B Vid Floor 3" Floor Floors thru Basement Accessory Structure"' Attached Garage Detached Garage Attached Carport Detached Carport Covered Deck Uncovered Deck PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq 11): Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact: Handicap: Will there be a change in use? 0 ....... Yes ....... No If "yes", explain: Previously a restaurant FIRE PROTECTION/HAZARDOUS MATERIALS: Z ....... Sprinklers JZ ....... Automatic Fire Alarm El ....... None E] ....... Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? El ....... Yes Z ....... No If "yes, attach list ofmaterials and storage locations on a separate 8-112 " x I I "paper including quantities and Material Safety Data Sheets. SEPTIC SYSTEM F1 ....... On-site Septic System — For on-site septic system, provide 2 copies of a current septic design approved by King County Health Department. li:\Applications\Forms-Applications On Linc\201 I ApplicationsTermit Application Revised - 8-9-1 I.docx Revised: August 2011 Page 2 of 4 bh PUBLIC WORKS PERNUT INFO, ATION — 206-433-0179 Scope of Work (please provide detailed information): No exterior work. CA before you Dig: 811 Please refer to Public Works Bulletin #1 for fees and estimate sheet. Water District F1 ... Tukwila ... Water District #125 El Highline El.. Renton Fj ... Water Availability Provided Sewer District ... Tukwila [:1 ... Valley View El Renton El .. Seattle ... Sewer Use Certificate El ... Sewer Availability Provided Sentic System: F On-site Septic System — For on-site septic system, provide 2 copies of a current septic design approved by King County Health Department. Submitted with A11111111cation (mark boxes which aDDI n ... Civil Plans (Maximum Paper Size — 2211 x 34") F� ... Technical Information Report (Storm Drainage) [I .. Geotechnical Report ... Traffic Impact Analysis F� ... Bond insurance Easement(s) El Maintenance Agreement(s) ... Hold Harmless — (SAO) El ... Hold Harmless — (ROW) Proposed Activities (mark boxes that apply): F1 ... Right-of-way Use - Nonprofit for less than 72 hours El Right-of-way Use - Profit for less than 72 hours El ... Right-of-way Use - No Disturbance Right-of-way Use — Potential Disturbance E) ... Construction/Excavation/Fill - Right-of-way El Non Right-of-way El ... Total Cut cubic yards ... Total Fill cubic yards El ... Sanitary Side Sewer El ... Cap or Remove Utilities El ... Frontage Improvements M ... Traffic Control F� ... Backflow Prevention - Fire Protection Irrigation _ Domestic Water El Work in Flood Zone El Storm Drainage ..Abandon Septic Tank Curb Cut 0 Pavement Cut F] Looped Fire Line El Grease Interceptor E] Channelization E] Trench Excavation [I Utility Undergrounding El ... Permanent Water Meter Size... WO # ... Temporary Water Meter Size.. WO # ... Water Only Meter Size ............ WO # El ... Deduct Water Meter Size F] ... Sewer Main Extension ............. Public Private M M ... Water Main Extension ............. Public E] Private M FINANCE INFORMATION Fire Line Size at Property Line Number of Public Fire Hydrant(s) F� ... Water El ... Sewer El ... Sewage Treatment Monthly Service Billing to. Name:. Mailing Address: Day Telephone: city Water Meter Refund/Billing: Name: Day Telephone: Mailing Address: City H:\Applications\Foms-Applications On Linc\2011 Applications\P�it Application Revised - 8-9-1l.docx Revised: August 2011 bh State Zip State zip Page 3 of 4 PERMIT APPLICATION NOTES — Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING 0!"IKR I Signature: qckL Print Name: Mailing Address: lqqS Date: 3 1 P-- I I � Day Telephone: IL I 4� 0 a, q IS city State zip H:\Applications\Foms-Applications On Linc\2011 ApplicationsTernfit Application Revised - 8-9-1 I.doex Revised: August 2011 Page 4 of 4 bh DESCRIPTIONS PermitTRAK ACCOUNT QUANTITY PAID $5,854.37 D16-0349 Address: 17250 SOLITHCENTER PKWY Unit132 Apn:7888920020 $5,854.37 DEVELOPMENT $5,575.80 PERMIT FEE ROOO.322.100.00.00 0.00 $5,571.30 WASHINGTON STATE SURCHARGE B640.237.114 0.00 $4.50 TECHNOLOGY FEE $278.S7 TECHNOLOGY FEE TOTAL FEES PAID BY RECEIPT: R10972 ROOO.322.900.04.00 0.00 $278.57 $5,854.37 Date Paid: Thursday, March 02, 2017 Paid By: D P INC GENERAL CONTRACTORS Pay Method: CHECK 94112 Printed: Thursday, March 02, 2017 1:07 PM I of 1 CRWIYSTEMS Date Paid: Thursday, December 22, 2016 Paid By: JPC ARCHITECTS Pay Method: CHECK 33313 Printed: Thursday, December 22, 2016 12:15 PM 1 of 1 01,WW'SYSTEMS INSPECTION RECORD qq Retain a copy with permitF"(1- - o.' INSPECTION NO. . PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-36 Permit Inspection Request Line (206) 438-9350 Project: ot inspection:',,�,, SrAmk�' M&--7- e&bJ11-- Address: Date Called: 1 71sv k%o( Special Instructions: Date Wante d: &h7 e� �PJ NlApproved per applicable codes. Corrections required prior to approval. COMMENTS: /A lAf Ole AL Inspecto Date: X I -04� F-1 REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. INSPECTION RECORD L Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OFTUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project: .- Me7— "-b 1 -7— Type of Inspection: Address: r7n-o �CU�-vyy Date Called: Special Instructions: Date Wanted: a.m. 24!� Requester: Phone No: XAppr,oved per applicable codes. —1 Corrections required prior to approval. �%' E COMMENTS: Inspector: A Date: F] REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Cali to scheduie reinspection. ej INSPECTION RECORD Retain a copy with permit vig INSPEZTION NO. PERMIT NO. CITY OFTUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project: owz 0 Aet i -r Type of Inspection: Agvb Address: / -722) Sa��e PAxj4 Date Called: Special Instructions: Oi;)T- 13 a Date Wante 5 - Z-',) 7 p.m. I-R-e-q-u-e-st—er7- 7 Phone No: 91 Approved per applicable codes. Corrections required prior to approval. COMMENTS: Inspector: 4 Date: A A 1-1 5 -'b '7 F1 REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. INSPECTION RECORD k -fl, 1) 3q� ( k �,// etain a copy with permit 11%, 0" 1 INSPECTRON NU.— PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 5outhcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project: A11ZC 41:�L &&311r - -V IF Inspection: T� Address: Date Called: 172,0 S�VM96MK' fll-W� Special Instructions: Date Wanted: a.m. 5 7 Requester: Phone No: r-1 Approved per applicable codes. a, Corrections required prior to approval. V4 - IInspector: A bA"X I Uate: �� hf11 7 1 REINSPECTION FEE REQUIRED. Prior to next inspedion. fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to scheclute reinspection. INSPECTION RECORD. VIC r-7) Retain a copy with per 51/6 - -0 t I N SVZf.;40 N N 0. PERMIT NO. CITY OFTUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila * WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 DApproved per applicable codes. X Corrections required prior to approval. Inspector: Date: F] REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd- Suite 100. CaR to schedule reinspection. 40-1 1 INSPECTION RECORD V7 . lbi6 - OIL? Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Pro ect: C Type. of Inspection: Address: / 72V,-? Date Called: Special Instructions: 0/0,1— Date Wanted: a.m. p.m. Requester: Phone No: FA71 Approved per applicable codes. Corrections required prior to approval. X -N E I Inspector: HIREINSIPECTION FEE REaUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd., Suite 100. Cali to schecluie reinspection. INSPECTION RECORD. '4 7q Retain a copy with permit �16 INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd— #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project: , A17LC r-4gr 'Sc %7r L)Apo Type of Inipection: am Address: J -72Z -�rj N742AX led: I Special Instructions: tjA)rr 132- — Date Wantec 10- �19. i7 "P5. Req ue4ste -7- Phone No: fffApproved per applicable codes. E] Corrections required prior to approval. nspector: Date: F] REINSPECTION FEE REQUIRED. Prior to next inspegction'fee must be paid at 6300 Southcenter Blvd., Suite 100. Catt to schedule reinspection. INSPECTION RECORD. /6, Retain a copy with pe� m t $�� INSPECTION NO. PERMIT NO. I CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project: Type of Inspection: S&-Irw ML017 Address: Date Called: / 72S-6 P4�, Special Instructions: — (A) R Date Wante a. -7, /?,4-0 61t lRequestel. M 11/0 Phone No: Vo — Z/Z//- J im Approved per applicable codes. psi Corrections required prior to approval. MMENTS: F-1 REINSPECTION FEE REQUIRED. Prior to next inspeetion, fee must be paid at 6300 Southcenter Blvd., Suite 100. Catl. to schedule reinspection. INSPECTION RECORD P/4?- 0.3 Retain a copy with p ermit INSPECTION NO. PERMIT NO. CITY OFTUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project: z5a+TrW- meROPOLi mW , Type of Inspection: Z=)FZ�IA16- Address: e7RAN) 172SO . IT V.1VtC>'t*' 56011*-WJTV� PKWY, Date Called: Special Instructions: Uj 17— 13 Date W ted. a -M) 7 —a5-1 1 Requester: Phone No: EXApproved per applicable codes. 1 11 Corrections required prior to approval. MMENTS: Kt1N:)rtUJ 1UN t-tt KtUUIKLU. Frior to next inspection, tee must lie paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit INMCTION NO. PERMIT NO. CITY OFTUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project: filer-- tx—t—b/T— TyE�.�spection: Address: nXz> pytil-I Date Called: J I Special Instructions: I )%z Date Wanted Y�ZqZ17 p.m. lRequestec/ Phone No: 0 Appnoved per applicable codes. Corrections required prior to approval. " paid at 6300 Southcenter Blvd., Suite 100. Call to s�heclule reinspection. INSPECTION RECORD. JW -03W IN'51�101\1 NO, etain a copy with permit PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 1:1 Approved per applicable codes. 1-1 Corrections required prior to approval. COMMENTS: Inspector: -4A Date: F-1 REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call. to schedule reinspection INSPECTION F,ECOIRD. -,93177 Retain a copy with permit 19 1� VKPECTION NO. PERMIT NO. CITY OFTUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 P Type of Inspection: Ardress: Date Calle 13 Special Instructions: Date Wanted: -3t:l 7 Requester: Phone No: 11 Approved per applicable codes. [A Corrections required prior to approval. !,COMMENTS:. F f M7'j �A A ARM N 07J ff- H wimnlwrl WAN MIRMA NAMMErmw Inspector: V" Date: -5 --5 El REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. q INSPECTION NUMBER INSPECTION RECORD Retain a copy with permit PERMIT NUMBERS CITY OF TUKWILA FIRE DEPARTMENT 206-575-4407 Project: Type of Inspection: Address: Contact Person: suite #: Pre -Fire: Special Instructions: Phone No.: QrApproved per applicable codes. Corrections required prior to approval. COMMV4TS: -I-- 111—/5 Needs Shift Inspection: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: Inspector:—.f-�-� I Date: -7 1 Hrs.: F—] $100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. willing ACIaress Attn: Company Name: Address: City: State: zip: Word/Inspection Record Form.Doc 3/14/14 T.F.D. Form F.P. 113 5 INSPECTION NUMBER INSPECTION RECORD Retain a copy with permit 2 AF ely, �� . I PERMIT NUMBERS CITY OF TUKWILA FIRE DEPARTMENT 206-575-4407 Project: 5A�7L/11/1 Type of Inspection: ff --/,) 4 - Address: Confkt Person: #: /1,9, 5—V Pre -Fire: -Suite Special Instructions: Phone No.: J,K,� Approved per applicable codes. FICorrections required prior to approval. COMMENTS: Aar w/ &Nzeyt-4tbjeni LJ(1A Needs Shift Inspection: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: I inspector: -IM 57Z�- 1 Date: 11V, I Hrs.: I I [—] $100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. Billing Address Attn: Company Name: Address: City: State: zip: Word/Inspection Record Form.Doc 3/14/14 T.F.D. Form F.P. 113 INSPECTION RECORD Retain a copy with permit INSPECTION NUMBER PERMIT NUMBERS CITY OF TUKWILA FIRE DEPARTMENT 206-575-4407 Project:,-- Type of Inspection Address: Suite #: Contact Person: Special Instrudions: Phone No.: —1 Corrections required prior to approval. Approved per applicable codes. I COMMENTS: Sprinklers: L( .-o Hood & Duct: 046- -/ Pre -Fire: 4� & Occupalncy Type: ;�-t )YL 0 V E S Needs Shift Inspection: Sprinklers: L( Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: Occupalncy Type: 4 -(1 -r- , -Date: Inspector: H rs.: F-1 $100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. tsining Aaaress Attn: Company Name: Address: City: State: zip: Word/Inspection Record Form.Doc 3/14/14 T.F.D. Form F.P. 113 INSPECTION RECORD Retain a copy with permit INSPECTION NUMBER N 0 650:� PERMIT NUMBERS CITY OF TUKWILA FIRE DEPARTMENT 206-575-4407 Project: Type of Inspection: Address- ztt, Suite #:' Contact erson: Xrc Special Instructions: Phone No.: —1 Corrections required prior to approval. Approved per applicable codes. COMMENTS: P -6 d(-, 1-c,> 6-6�1 C - Needs Shift Inspection: Sprinklers: Y�'— -' Fire Alarm: Hood& Duct:' 6�;> Monitor: Pre -Fire: i /,J�w Permits: Occupancy Type: Inspecto, r: Date: H rs.: I F—] $100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. Bming Aaaress Attn: Company Name: Address: City: State: zip: Word/Inspection Record Form.Doc 3/14/14 T.F.D. Form F.P. 113 I -(L 2015 Washington State Energy Code Compliance Forms for Commercial Buildinqs includinq R2, R3. R4 over 3 stories and all R1 Revised Atinimt Pni F; Project Info Project Title: SMCU Southcenter Date 7/1/2016 Compliance Applicant Information. Provide contact information for individual who can For Building Department Use forms do not respond to inquiries about compliance form information provided. require a password to Company Name: JPC Architects PLLC Company Address: 909 11 2th Ave NE Bellevue, WA 98004 use. Instructional and calculating cells L Lin Applicant Name: Teresa Portman are write - protected. Applicant Phone: 206-641-9200 Applicant Email: teresap@jpcarchitects.com Project Description [:] New Building Addition Alteration Plans Included Include PROJ-SUM form (included in envelope forms workbook) with lighting compfflance forms. Building Additions Compliance Method Interior lighting Exterior lighting Lighting systems in addition area comply with all applicable El Refer to Section C502.2.6 for additional provisions as a stand alone new construction project Lighting systems in addition are combined with existing El requirements. building lighting systems to demonstrate compliance Addition is combined with existing: For interior lighting projects, include new + existing interior lighting fixture wattage in Proposed Lighting Wattage table in LTG -INT -BLD or L TG -INT -SPACE form. For exterior lighting projects, include new + existing exterior lighting fixture wattage in Proposed Tradable and Proposed Non -Tradable Lighting Wattage tables in LTG -EXT form. Interior and Exterior Lighting Power Interior lighting Parking garage Exterior lighting 50% or more of existing are replaced 21 El Lighting Alterations Select all Lighting Power and Lighting Control elements that apply to the scope Less than 50% of existing are replaced 1:1 El 1:1 of the retrofit project. If project includes a Lamp and/or ballast replacement only combination of spaces where less than 50% of the existing fixtures are replaced - existing total wattage not increased in some spaces, and 50% or more of the fixtures are replaced in others, then 50% or more replaced - Total lighting power of new + existing -to -remain fixtures shall comply with total provide separate lighting power LPA per Sections C405.4.2 and C405.5.2. Include new + existing -to -remain fixtures in Proposed compliance forms for the two retrofit Lighting Wattage table in LTG -INT -BLD, LTG -INT -SPACE or L TG -EXT form. conditions. Spaces undergoing the same Less than 50% replaced - Total lighting power of new + existing -to -remain fixtures shall not exceed the type of retrofit may be combined into one total lighting powerprior to alteration. Include new + existing -to -remain fixtures in the Proposed Lighting lighting power compliance form. Wattage table in L TG -INT -BLD, L TG -INT -SPACE or L TG -EXT form. 50% threshold applies to number of luminaires for interior spaces and parking garages, and total Refer to Section C503.6 for additional installed wattage for exterior luminaires. requireme v4r:- C FCR Lighting Controls Interior lighting Parking garage Exterior lighting ew n inst wiri alled to serve added IN -1 r Jg All alter vonligktig t I -shallbe,.ICE n6 r%i-4 Comm "p -08.,*3. fixtre, ancl/,, fixtures relocated to new El F APPROVED A Icircuit(s) JAN 17 Nev New or moved lighting panel Lnor nterior space is reconfigured - m m inaires unchanged or relocated only City of Tukwila ew wiring or circuit - For interior lighting, provide required manual controls per C405.2.3, occupancy N slo en, ensor controls per C405.2. 1, daylight responsive controls per C405.2.4 and application specific lighting C405.2.5. UIVI E] No h 10b '01, a'.Y.' n ntrols per For exterior lighting, provide required controls per C405.2.7 the or exterior lighting New or moved panel - Provide all applicable lighting controls as noted for New Wiring and automatic systems and existing space uses and configuration are not time switch controls per C405.2.2. _P Reconfigured interior space - Provide lighting Ye Peripr.2pace. changed. all required controls that% _91 Application specific lighting control provisions per C405.2.5 do notauNo Wnf1gUK*b[tA Change of Space Use 7 Existing interior lighting systems in areas under -going a change in s sumexted to = comply with LPAs for the new space types per Tables C4( I I . A Identify interior spaces requiring LPD upgrade to the current Code in Progose it ' in LTG -INT -BLD LTG form. P- MY WN or -INT -SPACE M 2015 Washinqton State EnerqV Code Compliance Forms for Commercial Buildinas includino R2_ R3. R4 over 3 stories ;;nd Ali R1 R—i—i A. � —f 9r)l A Project Title: SMCU Southcenter Tate 7/1/2016 Interior Lighting System All new light fixtures to be installed to accommodate new build out. Majority are LED pendant Description fixtures or recessed 2x4 in -grid fixtures. Interior Lighting Power E] Building Area Method Space -by -space Method Allowance Method Select method used in project Interior Lighting Controls 7 All C405.2.1 - C405.2.8 Controls C405.2 Exception 5 Luminaire Level Lighting Control (LLLC) F� Additional Efficiency Package Option C406.4 Enhanced digital lighting controls To comply with C406.4, no less than 90% of the total installed interior lighting power shall comply with the requi I red controls per C406.4. Dwelling Unit Interior Permanently installed interior lighting fixtures in dwelling units comply with: Lighting 0 C405.2 thru C405.5 Commercial Lighting Controls and LPA 0 C406.3 High Efficacy Lighting 0 Exterior Lighting System Description 2015 Washington State Energy Code Compliance Forms for Commercial Buildincls includinq R2, R3, R4 over 3 stories and all R1 Revised Auaust 2016 Project Title: SMCU Southcenter Fixture Description NOTE 4, 5, 6 Date 7/1/2016 Calculation 0 0 Addition - 0 Addition 1000,1003,2003, 2000,2obo For Building Department Use Area NOTE 9 stand alone + existing 805 1003, 1020,2003 F-2 Pendant LED 3 0 Spaces where < 50% of 0 Spaces where ? 50% of 0 174 1018, 1019, 1017, 1016, 1008, 1005, 1010,1011 F-3 Recessed Can LED 29 luminaires are replaced luminaires are replaced 377 1020 F-4 Recessed Can LED LPA Standard 0 Additional Efficiency Package Option 0 Calculation C406.3 Reduced Interior Lighting Power 18 1019 ' 1018 ' 1016, 1008,2001 F-5 Pendant LED To comply with C406.3, the Proposed LPD shall be 25% lower than the Target LPA. 32 1021,1006, Type Refer to C406.3 for additional requirements. 4 32 128 Maximum Allowed Lighting Wattage""" F-7 Pendant LED 5 100 Location (plan FFeig-ht"-'- Gross Interior Allowed Watts Allowed room Space Type 2 Area in ft2 Watts per ft2 (wattS/ft2 x area) 1000,1001,1003, Banking activity area 1020,1017 1725 0.810 1397 1021 Storage room 115 0.500 S8 1008 Conference/meeting/multipurpose 44 0.980 43 1016 Conference/meeting/multipurpose 119 0.980 117 1018 Conference/meeting/multipurpose 130 0.980 127 1019 Conference/meeting/multipurpose 130 0.980 127 1015 Copy/print room 198 0.580 115 1010 Restroom: all other lis 0.780 90 1011 Restroom: all other 115 0.780 90 1014 Storage room 112 O.S00 56 2003 Conference/meeting/multipurpose 660 1 0.980 1 647 2002 Storage room 114 0.500 57 1006 Storage room 120 0.500 60 Total Area 3697 Retail Display Allowance from LTG -INT -DISPLAY Lobby Art/Exhibit Display Allowance from LTG -INT -DISPLAY NOTE8 Allowed Watts 2984 Proposed Lighting Wattager""' Location (plan #, room #) Fixture Description NOTE 4, 5, 6 Number of Fixtures Watts/ Fixture NOTE 7 Watts Proposed 1000,1003,2003, 2000,2obo F-1 4" Pendant LED 35 23 805 1003, 1020,2003 F-2 Pendant LED 3 S8 174 1018, 1019, 1017, 1016, 1008, 1005, 1010,1011 F-3 Recessed Can LED 29 13 377 1020 F-4 Recessed Can LED 1 18 18 1019 ' 1018 ' 1016, 1008,2001 F-5 Pendant LED 4 8 32 1021,1006, F-6 Pendant strip light 4 32 128 1001 F-7 Pendant LED 5 100 Soo 1001 F-8 Pendant LED 9 S9 531 1010 F -9A Fluor. 1 33 33 1011 F-913 Fluor. 1 66 66 1015 F-10 Undercabinet Light Fluor. 8 10 80 1015,1014,2002 F-1 1 Recessed LED 5 38 190 1010,1011 F-12 2 14 28 Proposed Retail Display Lighting from LTG -INT -DISPLAY Total Proposed Watts may not exceed Total Allowed Watts for Interior Lighting Total Proposed Wattsl 2962 Interior Lighting Power Allowance COMPLI Note 1 - Listall unique space types per Table C405.4.2(2) that occurin the project scope. Selectspace type categoryper from drop down menu. Note 2 - Indicate ceiling height for atriums and spaces utilizing the ceiling height adjustment per Table C405.4.2(2), Footnotes d thru f Note 3 - List all proposed lighting fixtures including exempt lighting equipment and existing -to -remain fixtures. dERMIT COORD COPY k PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: D16-0349 DATE: 12/23/16 PROJECT NAME: METROPOLITAN CREDIT UNION SITE ADDRESS: 17250 SOUTHCENTER PKWY X I Original Plan Submittal Revision # before Permit Issued Response to Correction Letter # Revision # after Permit Issued DEPARTMENTS: IN WO tj� Building Division Fire Prevention Planning Division N uWg k 1AIi blic Works Structural Permit Coordinator PRELIMINARY REVIEW: DATE: 12/27/16 Not Applicable F1 (no approvallreview required) REVIEWER'S INITIALS: APPROVALS OR CORRECTIONS: Structural Review Required El DATE: DUE DATE: 01/24/17 Approved Approved with Conditions El Corrections Required F-1 (corrections entered in Reviews) Notation: Denied El (ie: Zoning Issues) REVIEWER'S INITIALS: DATE: Perinit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg 0 Fire El Ping El PW El Staff Initials: 12/18/2013 D P INC GENERAL CONTRACTQ— � Horne. Espahol Contact Safety & Health Claims & Insurance kiWashington State Department of Labor & Industries I D P INC GENERAL CONTRACTORS Owner or tradesperson Principals DODSON, WILLIAM, PRESIDENT Doing business as D P INC GENERAL CONTRACTORS WA UBI No. 601515833 19936 BALLINGER WAY NE SEATTLE, WA 98155 206-361-2989 KING County Business type Corporation Page I of 2 ISearch L&I A -Z Index Help My L&I Workplace Rights Trades & Licensing ILicense I Verify the contractors active registration / license / certification (depending on trade) and any past violations. Construction Contractor Active. .................... .............. Meets current requirements. License specialties $1,000,000.00 GENERAL License no. DPINCGCO66BU Effective date Effective — expiration 09/15/2016 01/31/1994— 011/311/20118 Expiration date Bond 09/15/2017 Merchants Bonding Co (Mutual) $12,000.00 Bond account no. WA28622 Received by L&I Effective date 12/27/2012 01/31/2013 Expiration date Until Canceled Bond history Insurance Continental Western Ins Co $1,000,000.00 Policy 110, CPA6015605 Received by L&I Effective date 08/0412016 09/15/2016 Expiration date 09/15/2017 Insurance history Savinqj� No savings accounts during the previous 6 year period. Laws y.i.t.s-a.,.Q,ai.n..s.,t the. b.9 n -d or savings. No' I a -w , s . uits . a . g . a , i , ns . t .. th . a . bon d . o . r , s avi ngs accounts during the previous 6 year period. L&I Tax debts N 6 C&i' ii ;x d' ebts are recorded for this contractor license during the previous 6 year period, but some debts may be recorded by other agencies. Help us improve https:Hsecure. Inima. gov/verify/Detail. aspx?UBI=6015 15 8 3 3 &LIC=DPINCGCO66BU& SAW= 3/2/2017 D P INC GENERAL CONTRACTO-D S Page 2'of 2 License Violations N*6J16e­n­s­e­v* io'lit-io"ns during the previous 6 year period. IWorkers'comp Do you know if the business has employees? If so, verify the business is up-to-date on workers'comp premiums. L&I Account ID Account Is current. 578,236-01 Doing business as OPINC Estimated workers reported Quarter 4 of Year 2016 "Greater than 100 Workers" L&I account representative T2 / HAN CHUNG (360)902-4713 - Email: CHUK235@lni.wa.gov Workplace safety and health Check for any past safety and health violations found on jobsites this business was responsible for. Inspection results date 03/05/2014 Violations Inspection no. 316958065 Location 625 Andover Park W. Tukwila, WA 98188 @Washington State Dept, of Labor& Industries. Use of this site is subject to the laws of the state of Washington. Help us improve https:Hsecure.Ini.wa.gov/verify/Detail. aspx?UBI=601515 8 3 3 &LIC=DPINCGCO66BU& SAW= 3/2/2017 T 6 M Ln 00 CD C, _C, E iL;attie Metro P ohtan Credit Uniot7..,.ii t SOU�tHCEN�ER %"I" b� UARE 0",.Alite 1'32 111� U Site Plan Scale: :111M��M M �"M_ � MECHANICAL PERMIT ELECTRICAL PERMIT PLUMBING PERMIT FIRE ALARM SYSTEM FIRE SPRINKLER SYSTEM 0 DOCUMENTS FOR DEFERRED SUBMITTAL ITEMS SHALL BE SUBMITTED TO THE REGISTERED DESIGN PROFESSIONAL IN CHARGE (ARCH ITECT/ENGI NEER OF RECORD) FOR REVIEW PRIOR TO SUBMITTAL TO THE BUILDING OFFICIAL. 0 NO WORK SHALL PROCEED ON ANY DEFERRED SUBMITTAL ITEMS UNTIL THE DOCUMENTS HAVE BEEN APPROVED BY THE BUILDING OFFICIAL AND PERMIT OBTAINED. �b SOUTHCENTER SQUARE 17250.SOUTHCENTER PKWY SUITE 132 TUKWILA, WA 98188 -11% 'iT S E: rllil Pt NIF E F11t­__ a i REQUIR-71D dMectianical Electrical Plumbing Gas Piping City of Tu1,,w;!._1 BUILD 11.all."I DIV11%S;0;q krw;� Sheet Number Sheet Tit 1-0.0 Cover Sheet + Site Plan 1-0.1 General Notes + Symbols I—CS-1 Exit Plan + Codes Summary 1-1.1 First Floor Demolition Plan 1-1.2 Mezzanine Demolition Plan 1-2.1 First Floor Dimension Plan 1-2.2 Mezzanine Dimension Plan 1-3.1 First Floor Plan 1-3.2 Mezzanine Floor Plan 1-4.0 Lighting + Finish Specifications 1-4.1 First Floor Reflected Ceiling Plan 1-4.2 Mezzanine Reflected Ceiling Plan 1-6.1 First Floor Finish Plan 1-6.2 Mezzanine Finish Plan 1-9.1 Construction Details 1-9.2 Ceiling Details 1-9.3 Casework Details 1-10.1 Door Schedule Elevations + Details PROJECT ADDRESS: APPLICABLE EDITIONS OF BUILDING CODES: SOUTHCENTER SQUARE 17250 SOUTHCENTER PKW`Y. BUILDING 2015 INTERNATIONAL BLDG CODE (IBC), SUITE 132 CODE WAC 51-50 TUKWILA, WA 98188 FIRECODE 2015 INTERNATIONAL FIRE CODE (IFC), �10 C> 04 INCL. APPENDIX B&C CONSTRUCTION TYPE: ENERGY CODE 2015 WASHINGTON STATE ENERGY CODE CONST—TYPE 1 C_ (WSEC), WAC 51-11 FULLY SPRINKLERED C14 0) :3 > (1) MECHANICAL 2015 INTERNATIONAL MECHANICAL CODE (IMC), ZONE: CODE WAC 51-52 TUC—CC ELECTRICAL 2015 NATIONAL ELECTRICAL CODE (NEC) (NFPA OCCUPANCY: CODE 70) + PART 1 AND PART 3, 2009 BUSINESS (B) WASHINGTON CITIES: ELECTRICAL CODE WITH APPLICABLE RW 19.28 & WAC 296-46B TENANT SQUARE FOOTAGE: PLUMBING 2015 UNIFORM PLUMBING CODE (UPC), WAC (area of work) CODE 51-56 & 51-57 INCL. APPENDIX CHAPTERS H 2;N41 SF & L — EXCL. SECTIONS L5—L7 & "LAWN %,)-7 SPRINKLER HEAD" FROM TABLE 6-4 OF APPENDIX L ZONING CODE CITY OF TUKWILA ACCESSIBILITY PER ICC A117.1-2010 ACCESSIBLE AND CODE USABLE BUILDINGS AND FACILITIES SPRINKLERS COMPLYING WITH NFPA 13 (QUICK RESPONSE) ARE REQUIRED FOR THIS WORK PURSUANT TO IBC. Legal Description: TAX PARCEL #: 788892-0020 SOUTHCENTER SQUARE BSIP Vicin! LMP Plan raview L -Approval is subject to errors aria Uri 035 Val of con ruciion docurnonis does not nuim ilation of any adopted code or ordinance. Rc ,oved FiAol�Copy anda ond onsi acknowl3i By: Dat Property Manager: WIG PROPERTIES LLC 4811 134TH PLACE SE BELLEVUE, WA 98006 425.641.2044 DAVID KRUEGER dkrueger@wigproperties.com Tenant: SEATTLE METROPOLITAN CREDIT UNION 1521 1st AVENUE S SUITE 500 SEATTLE, WA 98134 206.398.5591 ROBIN BLEEKER robin. bleeker@smcu.com City of Tukwila BUILDING DIVISION PROJECT LOCATION * SOUTHCENTER SQUARE 17250 SOUTHCENTER PKWY SUITE 132 TUKWILA, WA 98188 Architect: JPC ARCHITECTS 909 112TH AVE NE SUITE 206 BELLEVUE, WA 98004 425.641.9200 TERESA PORTMAN — EXT. 370 teresap@jpcarchitects.com MARK PETERSON — EXT. 340 markp@jpcarchitects.com Amu S ]EATT.L.E. NEM.METkOPOLITAN 1111W CRI'Dit 11�N1`01N Southcenter Square 17250 Southcenter Blvd. Tukwila, WA 98188 DESIGN JPC DRAWN TIP I IVIS CHECKED TIP NO. 16-0699 REVISIONS No changes shall be made to thp scope Of Work without prior approval of Tulmila Building Div!si(-,,n )TE: I'Misiorz will roqUirea r,7 -',v plan submittai c.nfJ may inz;lfude additional plan revo;-.yj fces I I General Contractor: JOIRISDICT DIP INCORPORATED 19936 BALLINGER WAY NE SEATTLE, WA 98155 FRE F- -D D:V '�E MI 5P 206.361.2989 CO P AN OV LIC. NO. DPINCGCO66BU PP i D TRYGVE OYE trygve@dpinc.net 12.22.16 PERMIT RECEIVED CITY OF TUKWILA DEC 2 2 2016 PERMIT CENTER Cover Sheet + Site I Plan JAN 17 city of Tu 11a IV ;a BUILDING DI JISION PLLC '_1 U UJ �10 C> 04 V) Lij Z.,t C:) C) C_ 00 01- C14 0) :3 > (1) 0% 6 0- - (1) M Amu S ]EATT.L.E. NEM.METkOPOLITAN 1111W CRI'Dit 11�N1`01N Southcenter Square 17250 Southcenter Blvd. Tukwila, WA 98188 DESIGN JPC DRAWN TIP I IVIS CHECKED TIP NO. 16-0699 REVISIONS No changes shall be made to thp scope Of Work without prior approval of Tulmila Building Div!si(-,,n )TE: I'Misiorz will roqUirea r,7 -',v plan submittai c.nfJ may inz;lfude additional plan revo;-.yj fces I I General Contractor: JOIRISDICT DIP INCORPORATED 19936 BALLINGER WAY NE SEATTLE, WA 98155 FRE F- -D D:V '�E MI 5P 206.361.2989 CO P AN OV LIC. NO. DPINCGCO66BU PP i D TRYGVE OYE trygve@dpinc.net 12.22.16 PERMIT RECEIVED CITY OF TUKWILA DEC 2 2 2016 PERMIT CENTER Cover Sheet + Site I Plan JAN 17 city of Tu 11a IV ;a BUILDING DI JISION PLLC '_1 I U < x 0 CL m 0- �2 0 >1 E Abbreviations: A/C AIR CONDITIONNG ACT ACOUSTICAL CEILING TILE AFF ABOVE FINISH FLOOR ALT. ALTERNATE APPROX. APPROXIMATE BD BOARD BLDG BUILDING BLK BLOCK BLKG BLOCKING BOT BOTTOM B/S BUILDING STANDARD BU BUILT UP CAB CABINET CLG CEILING CLR CLEAR(ANCE) COL COLUMN CONC CONCRETE CONS CONSTRUCTION CONT CONTINUOUS CORR CORRIDOR CPT CARPET CT CERAMIC TILE CTR CENTER DEMO DEMOLITION DTL DETAIL DF DRINKING FOUNTAIN DIA DIAMETER DIM DIMENSION DN DOWN DR DOOR DWG DRAWING DRW DRAWER E EAST EA EACH EL ELEVATION ELEC ELECTRICAL ELEV ELEVATOR EQ EQUAL EQUIP EQUIPMENT EST ESTIMATE EXIST EXISTING EXP EXPANSION FEC FIRE EXTINGUISHER CABINET FF FACTORY FINISH FH FULL HEIGHT FIN FINISH(ED) FLR FLOOR FLUOR FLUORESCENT FDIC FURNISH BY OWNER, HDWR INSTALL BY CONTRACTOR FOS FACE OF STUD(S) FOC FACE OF CONCRETE FOF FACE OF FINISH FT FOOT/FEET FUR FURRED/FURRING GA GAUGE GC GENERAL CONTRACTOR GL GLASS/GLAZING GWB GYPSUM WALL BOARD HC HOLLOW CORE HCPD HANDICAPPED HDR HEADER HDWR HARDWARE HM HOLLOW METAL HORIZ HORIZONTAL HR HOUR HT HEIGHT HVAC HEATING VENTILATING SEAL AIR CONDITIONING INSUL INSULATION JAN JANITOR JT JOINT KIT KITCHEN LAM LAMINATE(D) LAV LAVATORY LH LEFT HAND MAX MAXIMUM MECH MECHANICAL MTL METAL MEZ MEZZANINE MFR MANUFACTURE(R) MIN MINIMUM MISC MISCELLANEOUS MTD MOUNTED MUL MULLION N NORTH NIC NOT IN CONTRACT NTS NOT TO SCALE OA OVERALL Oc ON CENTER OD OUTSIDE DIAMETER OH OPPOSITE HAND OPNG OPENING P -LAM PLASTIC LAMINATE PNL PANEL PR PAIR PTN PARTITION RAD RADIUS RB RESILIENT BASE RT RESILIENT TILE REF REFERENCE REFIR REFRIGERATOR REINIF REINFORCING REQ REQUIRED REV REVISION RH RIGHT HAND RM ROOM RO ROUGH OPENING S SOUTH SC SOLID CORE SEAL SEALANT SECT SECTION SHT SHEET Sim SIMILAR SPEC SPECIFICATION SQ SQUARE Ss STAINLESS STEEL STIL STEEL STOR STORAGE STRUC STRUCTURAL SUSP SUSPENDED TEL TELEPHONE TEMP TEMPERED TFTI TENANT FURNISHED & TENANT INSTALLED THK THICK(NESS) THRESH THRESHOLD TV TELEVISION TYP TYPICAL UNFIN UNFINISHED UNO UNLESS NOTED OTHERWISE VCT VINYL COMPOSITION TILE VEN VENEER VERT VERTICAL VESTI VESTIBULE VFY VERIFY VWC VINYL WALL CDVERING W WEST/WIDE W/ WITH WD WOOD W/o WITHOUT WT WEIGHT General Notes: 1 REFER TO BASIC BUILDING SPECIFICATIONS, REQUIREMENTS AND STANDARDS FOR EXISTING SHELL AND CORE CONSTRUCTION. ALL WORK IS TO BE COMPATIBLE WITH EXISTING CONSTRUCTION. 2. ALL WORK SHALL CONFORM TO APPLICABLE CURRENT FEDERAL, STATE AND LOCAL CODES. THE CONTRACTOR IS TO PROVIDE FOR ALL REQUIRED NOTIFICATION OF AND COORDINATION WITH CITY AND STATE AGENCIES, AND PROVIDE REQUIRED PERMITS. ALL TESTS AND INSPECTIONS ASSOCIATED WITH OBTAINING APPROVALS TO PROCEED WITH AND COMPLETE THE WORK SHALL BE PAID FOR BY THE CONTRACTOR. 3. THE INTENT OF THE CONTRACT DOCUMENTS IS TO INCLUDE ALL LABOR AND MATERIALS, EQUIPMENT AND TRANSPORTATION NECESSARY OR REASONABLY INFERABLE AS BEING NECESSARY FOR THE EXECUTION OF THE WORK. BY SUBMITTING A PROPOSAL, THE CONTRACTOR REPRESENTS THAT THOROUGH EXAMINATION OF THE SITE AND ALL EXISTING CONDITIONS AND LIMITATIONS HAVE BEEN MADE AND THAT THE CONTRACT DOCUMENTS HAVE BEEN EXAMINED IN COMPLETE DETAIL, AND THAT IT IS DETERMINED BEYOND DOUBT THAT THE DRAWINGS, SPECIFICATIONS AND EXISTING CONDITIONS ARE SUFFICIENT, ADEQUATE AND SATISFACTORY FOR CONSTRUCTION OF THE WORK. WHERE MINOR ADJUSTMENTS TO THE WORK ARE NECESSARY FOR THE PURPOSES OF FABRICATION AND INSTALLATION OF ITEMS, OR RESOLUTIONS OF CONFLICTS BETWEEN ITEMS, WITHIN THE INTENT OF THE CONTRACT DOCUMENTS, THE CONTRACTOR SHALL MAKE SUCH ADJUSTMENTS AT NO ADDED EXPENSE TO THE OWNER. WHERE SUCH MINOR ADJUSTMENTS AFFECT FUNCTIONAL OR AESTHETIC DESIGN OF THE WORK, THEY SHALL BE SUBMITTED TO THE ARCHITECT FOR REVIEW AND APPROVAL. 4. THE CONTRACTOR SHALL COORDINATE ALL OPERATIONS WITH THE OWNER, INCLUDING AREA FOR WORK, MATERIALS STORAGE, AND ACCESS TO AND FROM THE WORK, SPECIAL CONDITIONS OR NOISY WORK, TIMING OF WORK AND INTERRUPTION OF MECHANICAL AND ELECTRICAL SERVICES. NOISY OR DISRUPTIVE WORK SHALL BE SCHEDULED AT LEAST ONE (1) WEEK IN ADVANCE OF THE TIME WORK IS TO COMMENCE. 5. ALL WORK SHALL BE PERFORMED IN ACCORDANCE WITH THE HIGHEST STANDARD OF WORKMANSHIP IN GENERAL AND WITH SUCH STANDARDS AS ARE SPECIFIED. 6. CONTRACTOR SHALL ADHERE TO ALL BUILDING STANDARDS. ANY CHANGES TO SAME SHALL BE SUBMITTED TO ARCHITECT IN WRITING FOR APPROVAL. 7. CONTRACTOR SHALL SUBMIT SAMPLES OF ALL FINISHES OF SUCH SIZE AND NUMBER THAT THEY REPRESENT A REASONABLE DISTRIBUTION OF COLOR RANGES AND PATTERN PRIOR TO INSTALLATION FOR ARCHITECT'S APPROVAL. CONTRACTOR SHALL PROVIDE SHOP DRAWINGS AND PRODUCT DATA FOR ARCHITECT'S APPROVAL ON ALL SPECIAL ITEMS REQUIRING CUSTOM FABRICATION. (SHALL INCLUDE RATED FIRE DOORS AND HARDWARE). 8. CONTRACTOR IS TO VERIFY ALL DIMENSIONS AND CONDITIONS ON SITE AND NOTIFY ARCHITECT OF ANY DISCREPANCIES. CONTRACTOR IS NOT TO SCALE OFF DRAWINGS. 9. CONTRACTOR SHALL PROVIDE 18 -GAUGE SHEET METAL BACKING IN PARTITIONS FOR ALL WALL -MOUNTED FIXTURES AND DEVICES UNLESS INDICATED OTHERWISE ON THE DRAWINGS. 10. ALL FLOORS SHOULD BE LEVEL AND NOT VARY MORE THAN 1/4- IN 10'-0". THE CONTRACTOR SHALL NOTIFY ARCHITECT OF ANY CONDITIONS THAT DO NOT MEET THIS STANDARD. 11. ALL MATERIALS INDICATED TO MATCH EXISTING SHALL DO SO WITH RESPECT TO SIZE, SHAPE, COLOR, TEXTURE, PATTERN, QUALITY AND METHOD OF INSTALLATION INSOFAR AS PRACTICABLE AND SHALL BE APPROVED BY THE ARCHITECT BEFORE USE. 12. ALL FIREPROOFING DISTURBED DURING CONSTRUCTION SHALL BE REPLACED TO MATCH ORIGINAL FIRE PROTECTION LEVELS. (OBTAIN REQUIRED APPROVALS AND TESTING). 13. THE FLOORS MAY BE OCCUPIED DURING CONSTRUCTION. THE CONTRACTOR SHALL PROTECT ALL PERSONNEL, PASSERSBY OR VISITORS TO THE SITE FROM HARM AND INJURY. BARRIERS SHALL BE INSTALLED AS REQUIRED TO PROTECT EQUIPMENT INSTALLED DURING CONSTRUCTION. CAREFULLY MAINTAIN AND PROTECT MONUMENTS, BENCH MARKS AND THEIR REFERENCE POINT FROM BEING DESTROYED OR DISTURBED; REPLACE AS REQUIRED. 14. EXISTING WORK DAMAGED AS A RESULT OF WORK DONE UNDER THIS CONTRACT SHALL BE REPAIRED TO ORIGINAL CONDITION AND FINISHED TO MATCH ADJACENT FINISHES, SUBJECT TO ARCHITECT'S APPROVAL, AND AT NO ADDITIONAL COST TO OWNER. ALL REPLACEMENT MATERIALS REQUIRED TO MATCH EXISTING MATERIALS SHALL DO SO WITH RESPECT TO TYPE, PATTERN, TEXTURE, SIZE, SHAPE, COLOR AND METHOD OF INSTALLATION INSOFAR AS PRACTICABLE, AND SHALL BE APPROVED BY THE ARCHITECT AND OWNER PRIOR TO INSTALLATION. 15. ALL EXISTING MECHANICAL AND ELECTRICAL EQUIPMENT AND SERVICES DISRUPTED OR REMOVED DURING CONSTRUCTION SHALL BE RESTORED AND REPLACED UNLESS NOTED OTHERWISE. FIRE/LIFE SAFETY SYSTEMS TO BE MAINTAINED DURING CONSTRUCTION. 16. INSTALLATION OF MECHANICAL, ELECTRICAL AND STRUCTURAL SYSTEMS WILL REQUIRE OPENING OF SOME EXISTING WALLS, CEILINGS OR FLOOR CAVITIES. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE REPAIR OF THESE OPENINGS TO MATCH EXISTING, EXCEPT WHERE NOTED OTHERWISE. FILL ALL HOLES AND VOIDS IN FLOORS, WALLS AND CEILINGS WHICH RESULT FROM INSTALLATION OF WORK, AND REMOVAL OF EXISTING MATERIALS AND EQUIPMENT REQUIRED BY THIS CONTRACT. PATCHED AREAS SHALL MATCH THE MATERIALS, FINISHES, AND LEVELS ADJACENT, OR SHALL BE PUT IN THE PROPER CONDITION TO RECEIVE THE FINISH INDICATED. 17. OPENINGS REQUIRED FOR NEW WORK THAT PENETRATES EXISTING STRUCTURE SHALL BE COORDINATED WITH OWNER PRIOR TO COMMENCING THE WORK. ANY OPENING OVER 2" IN DIAMETER SHALL BE REVIEWED AND APPROVED BY OWNER. THROUGH CONCRETE SLABS OR WALLS, OR MASONRY WALLS, ALL ROUND HOLES SHALL BE CORE DRILLED WITH A DIAMOND DRILL AND ALL RECTANGULAR OPENINGS SHALL BE CUT WITH A DIAMOND SAW. IN NO CASE SHALL ANY STRUCTURAL MEMBER BE CUT. USE CARBIDE -TIPPED DRILLS FOR GYPSUM WALLBOARD PARTITIONS. KEEP OVERCUTTING TO A MINIMUM. MAINTAIN CONTINUITY AND INTEGRITY OF FIRE SEPARATION AT ALL TIMES. GROUT AROUND CONDUITS PASSING THROUGH CONCRETE WALLS AND FLOORS AND MASONRY WALLS. MAKE PATCHES WITH NEAT, TRIMMED EDGES; MATCH ADJACENT EXISTING WORK. 18. CONTRACTOR SHALL PROVIDE FLOOR LEVELING AS MAY BE REQUIRED AT SLIDING DOORS, RELITES WITHOUT BASE, CABINET WORK, AND OTHER LOCATIONS REQUIRING LEVEL SUBSTRATE. FEATHER CHANGES IN ELEVATION OVER SUFFICIENT AREA TO LIMIT TRANSITION SLOPE TO 1/8" PER FOOT. 19. MATERIALS, ARTICLES, DEVICES AND PRODUCTS ARE SPECIFIED IN THE DOCUMENTS BY LISTING ACCEPTABLE MANUFACTURERS OR PRODUCTS, BY REQUIRING COMPLIANCE WITH REFERENCED STANDARDS, OR BY PERFORMANCE SPECIFICATIONS. FOR ITEMS SPECIFIED BY NAME, SELECT ANY PRODUCT NAMED. FOR THOSE SPECIFIED BY REFERENCE STANDARDS OR BY PERFORMANCE SPECIFICATIONS SELECT ANY PRODUCT MEETING OR EXCEEDING SPECIFIED CRITERIA. FOR APPROVAL OF AN ITEM NOT SPECIFIED, SUBMIT REQUIRED SUBMITTALS, PROVIDING COMPLETE BACK-UP INFORMATION FOR PURPOSES OF EVALUATION. WHERE BUILDING STANDARD ITEMS ARE CALLED FOR, NO SUBSTITUTE WILL BE ACCEPTED. 20. CONTRACTOR SHALL PROVIDE FOR ALL WORK REQUIRED TO MAINTAIN COMPLIANCE WITH LOCAL FIRE CODE. PROVIDE FOR ALL REQUIRED SHOP DRAWINGS AND APPROVALS. CONTRACTOR IS RESPONSIBLE FOR PROVIDING FIRE ALARM SYSTEM AUDIBILITY. 21. MECHANICAL AND ELECTRICAL FIXTURES, OUTLETS, ETC., WHEN SHOWN ON THE ARCHITECTURAL DRAWINGS, ARE FOR LOCATION INFORMATION ONLY. MECHANICAL AND ELECTRICAL TO BE DESIGNED BY OTHERS. ALL CIRCUITING COORDINATION TO BE BY OTHERS. 22. CONTRACTOR IS TO PROVIDE DRAWINGS FOR ARCHITECT'S APPROVAL SHOWING LOCATIONS OF ALL HVAC THERMOSTATS, GRILLES AND DIFFUSERS, FIRE AND SMOKE DETECTION DEVICES INCLUDING SPRINKLERS, SMOKE DETECTORS, FIRE EXTINGUISHERS AND HOSE CABINETS, PLUMBING AND PLUMBING EQUIPMENT. 23. ANY CHANGE IN LIGHT FIXTURE PLACEMENT DUE TO INTERFERENCE OF MECHANICAL OR STRUCTURAL COMPONENTS MUST BE APPROVED BY THE ARCHITECT. 24. ALL PERMITS INCLUDING FIRE, MECHANICAL, AND ELECTRICAL TO BE FILED SEPARATELY. 25. ALL GYPSUM BOARD PARTITIONS SHALL BE TAPED, SPACKLED AND SANDED SMOOTH WITH NO VISIBLE JOINTS. PATCH AND REPAIR SURFACES TO MATCH ADJACENT OR ADJOINING SURFACES WHERE REQUIRED. ALL SURFACES SHALL BE ALIGNED. 26. MODIFY EXISTING SUBSTRATE AS REQUIRED TO RECEIVE NEW FLOORING MATERIALS, THUS PREVENTING NOTICEABLE LUMPS OR DEPRESSIONS. 27. ALL WORK SHALL BE ERECTED AND INSTALLED PLUMB, LEVEL, SQUARE AND TRUE. 28. REFER TO MILLWORK SHOP DRAWINGS FOR SPECIFIC DETAILS OF COORDINATION BETWEEN DRYWALL/MILLWORK CONDITIONS. 29. ALL GLASS SHALL BE CLEAR TEMPERED GLASS, UNLESS OTHERWISE NOTED. GLAZING TONG MARKS SHALL NOT BE VISIBLE. CLEAN AND POLISH ALL GLASS PRIOR TO PROJECT DELIVERY. 30. ALL MILLWORK TO BE FASTENED TO THE PARTITION. PROVIDE NON-COMBUSTIBLE BLOCKING FOR ALL MILLWORK NOT SUPPORTED BY FLOOR OR ABOVE 4'-0" HT. ALL CONCEALED LUMBER & BLOCKING TO BE FIRE TREATED. 31. CONTRACTOR TO PROVIDE SHOP DRAWINGS FOR: HVAC, CARPET SEAMING, LIGHTING, CASEWORK. 32. MOISTURE TEST - REQUIRED FOR ALL ON GRADE SLAB CONDITIONS DURING THE CONSTRUCTION ESTIMATING/BUDGETING PROCESS THE GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR OBTAINING FROM THE BUILDING OWNER DOCUMENTATION AS TO THE VAPOR EMISSIONS RATE (MOISTURE TEST) FOR ALL 'ON GRADE SLAB CONDITIONS'. THIS INFORMATION SHOULD THEN BE IMMEDIATELY SHARED BETWEEN THE ARCHITECT, THE ARCHITECTS' SELECTED FLOORING REPRESENTATIVE(S) AND FLOORING SUB -CONTRACTOR FOR REVIEW AND APPROVAL OF APPLICABLE MATERWS AND ANCILLARY INSTALLATION/FINISH PRODUCTS. IF NO MOISTURE TEST CAN BE FURNISHED OR IF FINDING ARE IN QUESTION THE GENERAL CONTRACTOR SHALL PERFORM THE FOLLOWING TESTS: A. PROVIDE (3) CALCIUM CHLORIDE MOISTURE TESTS FOR THE FIRST THOUSAND SQUARE FEET AND (1) TEST FOR EVERY ONE THOUSAND SQUARE FEET THEREAFTER AT ALL FLOORS WITHIN SCOPE OF WORK. THE CALCIUM CHLORIDE TEST SHALL BE CONDUCTED IN ACCORDANCE WITH THE LATEST EDITION OF ASTIM F 1869 "STANDARD TEST METHOD" FOR MEASURING VAPOR EMISSIONS RATE OF CONCRETE SUN -FLOOR USING ANHYDROUS CALCIUM CHLORIDE. PROVIDE A WRITTEN REPORT OF FINDINGS TO THE ARCHITECT AS NOTED ABOVE. B. PROVIDE A PH PENCIL TEST AT ALL FLOORS WITHIN SCOPE OF WORK. PROVIDE A WRITTEN REPORT OF FINDINGS TO THE ARCHITECT AS NOTED ABOVE. IF REQUIRED BY THE CALCIUM CHLORIDE TEST, A WATERPROOF MEMBRANE SHALL BE APPLIED TO ALL FLOORS WITHIN THE SCOPE OF WORK. THE WATERPROOF MEMBRANE(S) SHALL BE APPROPRIATED FOR EACH FINISH FLOORING APPLICATION AS SPECIFIED BY THE SPECIFIC FLOORING MANUFACTURER VIA THE ARCHITECT. A LICENSED INSTALLER SHALL BE UTILIZED FOR INSTALLATION/APPLICATION OF EACH SPECIFIC MEMBRANE (AS APPLICABLE TO THE FINISH FLOORING PRODUCT) AND A WRITTEN WARRANTY SHALL BE PROVIDED DOCUMENTING STRICT CONFORMANCE TO THE SPECIFIED MANUFACTURES INSTALLATION REQUIREMENTS TO ENSURE AND UPHOLD ALL PERFORMANCE AND LIFE CYCLE GUARANTEES. 33. CONCRETE SLAB ON GRADE REPAIR - MINOR SCOPE (100 SQUARE FEET OR LESS) WHERE CONCRETE SLAB ON GRADE INFILL AND TRENCHING MUST OCCUR; CONDUCT THE APPROPRIATE UNDER SLAB INVESTIGATION (VIA SONO -GRAPH AND/OR X-RAY) TO LOCATE EXISTING UTILITIES OR OTHER OBSTRUCTIONS THAT SHOULD NOT BE DAMAGED. SAW CUT SLAB AT SUBJECT AREA(S) AND PULL BACK THE EXISTING VAPOR BARRIER (IF PRESENT) AND PROTECT FOR FUTURE RE- INSTALLATION. EXECUTE THE NECESSARY UNDER SLAB WORK (INCLUDING EXCAVATION), BACKFILL AND RE -COMPACT THE SUBJECT AREA WITH THE PREVIOUSLY HELD MATERIALS (IF THE EXCAVATED MATERIALS ARE NOT SUITABLE FOR RE -INSTALLATION, DISCARD AND PROVIDE NEW FREE DRAINING GRANULAR MATERIAL). RE -COMPACT FILL SOIL TO AT LEAST 95% OF THE MAXIMUM DRY DENSITY (MDD) OBTAINED IN GENERAL ACCORDANCE WITH THE ASTM D 1557 TEST PROCEDURE. RE -INSTALL THE EXISTING VAPOR BARRIER AND BIND SEAMS WITH MINIMUM 3" WIDE PRESSURE SENSITIVE TAPE TO ENSURE AN AIR/MOISTURE RESISTANT BOND. ATTACH NEW INFILL TO EXISTING CONCRETE SLAB WITH 18 INCH LONG #4 REBAR AT 24 INCHES ON CENTER EMBEDDED 8 INCHES INTO THE EXISTING CONCRETE SLAB WITH HILTI HY-150 ADHESIVE (OR SIMPSON SET ADHESIVE). REINFORCEMENT SHALL BE INSTALLED PER ADHESIVE MANUFACTURIER'S RECOMMENDATIONS. PROVIDE W2 X W2 X 6 X 6 WELDED WIRE FABRIC WITHIN SUBJECT AREA(S), INFILL SLAB TO MATCH THICKNESS OF ADJACENT SURFACE(S) (BUT NOT BE LESS THAN FOUR INCHES THICK) AND #4 DOWELS SHALL BE CENTERED IN SLAB. THE CONCRETE SHALL HAVE A. MINIMUM .28 DAY - COMPRESSIVE STRENGTH OF 3000 PSI WITH A MAXIMUM WATER CEMENT RATION OF 0.58 AND IS TO BE PLACED LEVEL WITH ADJACENT SURFACES. LET CURE AND PROVIDE MOISTURE TESTING AS SPECIFIED ABOVE. IF SCOPE OF WORK INCLUDES STRUCTURAL ELEVATED SLABS CONSULT A STRUCTURAL ENGINEER. REFER TO STRUCTURAL PLANS, IF APPLICABLE, FOR ADDITIONAL SPECIFICATIONS AND REQUIREMENTS. 34. CLEAN, REPAIR ANY EXISTING PERIMETER BLINDS AS REQUIRED TO BE IN A FULLY FUNCTIONING & OPERATIONAL MANNER. 35. COORDINATE WITH SUB -CONTRACTORS THE LOCATIONS OF ELECTRICAL AND VOICE/DATA OUTLETS, PLUMBING AND OTHER DEVICES WITH LAYOUT AND DESIGN OF CUSTOM CASEWORK. 36. CASEWORK SHALL CONFORM TO A.W.I. CURRENT STANDARDS. 37. EGRESS LIGHTING SHALL BE DESIGNED BY A LICENSED ELECTRICAL ENGINEER BASED ON FINAL FLOOR PLAN(S) AND THE MOST CURRENT (IN FORCE) ISSUE OF THE IBC, IEC AND LOCAL CODES/ORDINANCES. THE ENGINEER MAY USE THE ARCHITECTS EGRESS MAPS (COMMON PATH OF TRAVEL/EXIT TRAVEL DISTANCE) AS STARTING POINT FOR A BASIS OF DESIGN. HOWEVER, IT SHALL REMAIN THE SOLE RESPONSIBILITY OF THE ENGINEER TO COMPLETE A SCOPE OF WORK THAT ADDRESSES ALL EGRESS LIGHTING I.E.; ROOMS, SPECIALIZED SPACES, PATHWAYS, ETC. PER THE AFOREMENTIONED CODES. FINAL EGRESS LIGHTING QUANTITIES AND LOCATIONS SHALL BE DETERMINED BY BUILDING AND FIRE INSPECTOR'S FIELD PLACEMENT DETERMINATION. DOOR NUMBER REFERENCE. A3 REVISION REFERENCE <i > INTERIOR ELEVATION SYMBOL 1-0 C=� C14 0 Ln Uj Z a) C:) = C:) C: 00 04 (D > a) 0- - 6 (5 0% Cm ,A= S EATTLE %1M METROPOLITAN A� C P"t D I T O'��N folq Southcenter Square 17250 Southcenter Blvd. Tukwila, WA 98188 DESIGN JPC DRAWN TP I MIS CHECKED TP NO. 16-0699 12.22.16 PERMIT RECEIVED CITY OF TUKWILA DEC 2 2 2016 PERMIT CENTER DEE I -_ --I IN VIEWED ral Notes + T co COD-COMPI L! �iPPROV)ED ymbols DETAIL REFERENCE BUBBLE 1 7 17 2017 All IN JOB NORTH 4 V C ty of Tukwila REFERENCE KEY I ING DIVISION (REFER TO SHEET/KEY NOTES)T_ 10,1 @ 2013, JPC Architects, PLLC SCOPE OF WORK Floor 1 Occupant Load: REFER TO 2015 IBC TABLE 1004.1.2 FOR LOAD FACTOR Oman! Oman SEEN! Samoa WOMEN Minimal Oman Minimal Malawi Malawi Millions 101001110 Malawi 101001110 Samoa Oman Somalia Malawi Nana anown anon Names wommona, Room Number Square Footage Load Factor Occupant Load B OPEN OFFICE 1001 1,725 )/100 18.0 B STORAGE 1006 120 Y300 1-0 a) a PRIVATE COLLABORATION 1008 44 yl 5 3.0 M 1009 B J -7 5 -SF - 1:300 7SF 1 OCC C ci OP N N 1001 Ll OPEN COFFEE C, , %B 1,725 18 nrr_ 1:1 rM TOTAL TRAVEL DISTANCE an � an i an � mom 10110 an I INE General Notes: 1 MEANS OF EGRESS ILLUMINATION: THE MEANS OF EGRESS (EXIT PATHWAY) AND THE EXIT DISCHARGE DOOR SHALL BE ILLUMINATED AT ALL TIMES THE BUILDING IS OCCUPIED AT AN ILLUMINATION LEVEL NOT LESS THAN 1 -FOOT CANDLE (10 LUX) AT THE WALKING SURFACE LEVEL PER SBC 1006. LIGHTING MUST BE PROVIDED WITH EMERGENCY BATTERY BACK-UP PER SBC 1006.3. 2. EGRESS LIGHTING SHALL BE DESIGNED BY A LICENSED ELECTRICAL ENGINEER BASED ON FINAL FLOOR PLAN(S) AND THE MOST CURRENT (IN FORCE) ISSUE OF THE IBC, IEC AND LOCAL CODES/ORDIANANCES. THE ENGINEER MAY USE THE ARCHITECTS EGRESS MAPS (COMMON PATH OF TRAVEL/EXIT TRAVEL DISTANCE) AS STARTING POINT FOR A BASIS OF DESIGN. HOWEVER, IT SHALL REMAIN THE SOLE RESPONSIBILITY OF THE ENGINEER TO COMPLETE A SCOPE OF WORK THAT ADDRESSES ALL EGRESS LIGHTING I.C.; ROOMS, SPECIALIZED SPACES, PATHWAYS, ETC. PER THE AFOREMENTIONED CODES. FINAL EGRESS LIGHTING QUANTITIES AND LOCATIONS SHALL BE DETERMINED BY BUILDING AND FIRE INSPECTOR'S FIELD PLACEMENT DETERMINATION. Legend: 4 --- "COMMON PATH OF EGRESS TRAVEL" IS LESS THAN 100'-0" (75'-0" FOR NO QUICK RESPONSE OR NON SPRINKLERED) AS ALLOWED WITH BUILDING EQUIPPED THROUGHOUT WITH AN AUTOMATIC SPRINKLER SYSTEM, PER 2015 IBC 1006, TABLE 1006.2.1 FOR "B" OCCUPANCY 03 Q 98 40, 4/1 STORAGE 1006 9 B 120 SF 1:300 I/ COL ION F R N COL ION 1019 1018 B B 130 SF 130 SF 1:15 1:15 9 OCC 9 OCC WFR N/",�� 03 A Iv - "TOTAL EXIT ACCESS TRAVEL DISTANCE" IS LESS THAN 300'-0" (200'-0" FOR NO QUICK EXIT RESPONSE OR NON SPRINKLERED) AS ALLOWED WITH BUILDING EQUIPPED THROUGHOUT WITH AN AUTOMATIC SPRINKLER SYSTEM, PER 2015 IBC 1017, TABLE 1017.2 FOR "B" OCCUPANCY. B OCCp DENOTES OCCUPANCY - DENOTES SQUARE FOOTAGE xxxx SF 1:1 ' DENOTES OCCUPANT LOAD FACTOR XX OCCp UtNOTES NUMBER OF OCCUPANTS Key Notes: ADA PARALLEL APPROACH CLEARANCE PER ICC A117.1, SECTION 606.2, EXCEPTION 1. FIRE EXTINGUISHER CABINET ADA FORWARD APPROACH CLEARANCE PER ICC A117.1, SECTION 606.2 ALL NEW BUILT-IN COUNTERS REQUIRED TO BE ACCESSIBLE TO BE +34" HIGH PER ICC A117.1 SECTION 308.3.2. EXIT SIGN Plumbing Code Notes: 1. REFER TO IBC 2015 CHAPTER 29 TABLE 2902.1 FOR PLUMBING FIXTURE CALCULATIONS, MINIMUM FIXTURES REQUIRED. 2. TOTAL OCCUPANT LOAD = 59 OCCUPANTS ASSUME EQUAL PARTS MALE AND FEMALE = 30 MALE AND 30 FEMALE (1) STALL IS REQUIRED PER 25 OCCUPANTS FOR THE FIRST 50 OCCUPANTS, (1) PER 50 FOR THE REMAINDER EXCEEDING 50. (4) STALL ARE REQUIRED, (4) STALL ARE PROVIDED (EQUAL PARTS MALE AND FEMALE) 3. (1) LAVATORY IS REQUIRED PER 40 OCCUPANTS FOR THE FIRST 80 OCCUPANTS, (1) PER 80 FOR THE REMAINDER EXCEEDING 80. (2) LAVATORY IS REQUIRED AND (2) IS PROVIDED. EXIT Overall Building Plan Scale: N.T.S. PRIVATE C , 0 �44 S� COMMON PATH OF TRAVEL 26'-2" CONF R N 101692 8 119 SF 1:15 8 OCC MR cs- --<D (J 7 WORK F'100 �15 B 19 8 SF 1:300 1 OCC SCOPE OF WORK Name oname wooma nomon woman onown monon" 4%ftMoonw nowns Nonni woman unions Nonni Noonan 000­-!� EXIT . \ \ 3 0 �� 0 sm� Oman! Malawi Malawi SEEN! Oman momomm Mezzanine Exit Plan Scale: 1/4"=l' -O" STORAGE 110141 B 112 SF 1:300 1 OCC First Floor Exit Plan Scale: 1/4"=11'-O" TOTAL I 1 1 3,467 59.0 Code Notes: 1 . TOTAL USABLE AREA: 3,467 USF 2. TOTAL OCCUPANTS: 59 OCCUPANTS 3. THIS BUILDING IS SPRINKLERED AND HAS AN EMERGENCY VOICE/ALARIV COMMUNICATION SYSTEM, THEREFORE, PER IBC 1005.3.1 & 1005.3.2 EXCEPTION: 0.2" PER OCCUPANT FOR THE STAIRWAY AND 0.15" PER OCCUPANT FOR OTHER EGRESS COMPONENTS IS USED FOR THE FOLLOWING CALCULATIONS. (IF NOT, USE 0.3" PER OCCUPANT FOR THE STAIRWAY AND 0.2" PER OCCUPANT FOR OTHER EGRESS COMPONENTS). 4. EGRESS COMPONENTS WIDTH REQUIRED: 59 * 0.2 = 11.8". V) Floor 1 Occupant Load: REFER TO 2015 IBC TABLE 1004.1.2 FOR LOAD FACTOR Occupancy Room Name Room Number Square Footage Load Factor Occupant Load B OPEN OFFICE 1001 1,725 )/100 18.0 B STORAGE 1006 120 Y300 1-0 a) a PRIVATE COLLABORATION 1008 44 yl 5 3.0 - (L) B ATM / ITM 1009 115 Y300 1.0 B STORAGE 1014 112 Y300 1.0 B WORK ROOM 1015 198 Y300 1.0 B CONFERENCE 1016 119 yl 5 8.0 B CONFERENCE 1018 130 yl 5 9.0 B CONFERENCE 1019 130 yl 5 9.0 B STAFF AREA 2001 660 Y1 00 7 1 B ISTORAGE 1 2002 1 114 1 IV3 0 0 1 TOTAL I 1 1 3,467 59.0 Code Notes: 1 . TOTAL USABLE AREA: 3,467 USF 2. TOTAL OCCUPANTS: 59 OCCUPANTS 3. THIS BUILDING IS SPRINKLERED AND HAS AN EMERGENCY VOICE/ALARIV COMMUNICATION SYSTEM, THEREFORE, PER IBC 1005.3.1 & 1005.3.2 EXCEPTION: 0.2" PER OCCUPANT FOR THE STAIRWAY AND 0.15" PER OCCUPANT FOR OTHER EGRESS COMPONENTS IS USED FOR THE FOLLOWING CALCULATIONS. (IF NOT, USE 0.3" PER OCCUPANT FOR THE STAIRWAY AND 0.2" PER OCCUPANT FOR OTHER EGRESS COMPONENTS). 4. EGRESS COMPONENTS WIDTH REQUIRED: 59 * 0.2 = 11.8". V) Foo -s - U loo - 110 C) C%4 a) L/I Lid z 00 0- a) 4-J C%4 V- > Q) 0- 6 - (L) L" SEATTLE VEM METROPOLITAN A�CRIEDIT UNION Southcenter Square 17250 Southcenter Blvd. Tukwila, WA 98188 DESIGN JPC DRAWN TIP I IMS CHECKED TIP NO. 16-0699 12.22.16 PERIM11T 0 RECEIVED . CITY OF TUKWILA DEC 2 2 2016 PERMIT CENTER 5. MINIMUM (2) EXITS REQUIRED PER IBC 1021.2, , (2) EXITS HAVE BEREVIEWElIZAR PROVIDED. COD = COMPLIANC 6. EGRESS DOORS WITH CARD READERS SHALL BE FAIL-SAFE TO RE VAIN &PPROVED UNLOCK DURING AN EVENT/EMERGENCY. J M 17 2017 7. NON -EGRESS DOOR WITH CARD READERS SHALL BE FAIL-SAFE T9 - REMAIN LOCK DURING AN EVENT/EMERGENCY. DOOR CAN STILL B CIty of Tukwila OPEN WITH A KEY DURING SUCH EVENT/EMERGENCY. [BUIL)ING DIVISIAl W 'Ian + Codes ummary CS -1 @ 2013, JPC Architects, PLLC z SCOPE OF WORK V) x 0 C -D C, CN V) 0 E Symbols Legend: ME== ELECTRICAL PANEL NO DESIGNATION = EXISTING D = DEMOLISH TYR El Key Notes: NO WORK THIS AREA, UNLESS OTHERWISE INDI CATED. REMOVE EXISTING STOREFRONT SYSTEM AS NECESSARY TO ACCOMMODATE NEW AUTOMATIC TELLER MACHINE. REFER TO FLOOR PLAN FOR NEW SCOPE OF WORK. DEMOLISH AND DISPOSE OF EXISTING COUNTERTOP, BACKSPLASH + SINK. PATCH AND REPAIR AFFECTED AREAS, INCLUDING BUT NOT LIMITED TO WALLS, FLOORS AND CEILINGS AS REQUIRED MATCHING EXISTING FINISH MATERIALS, UNO. EXISTING ELECTRICAL PANELS SCHEDULED TO REMAIN. EXITING TOILET PARTITIONS AND HARDWARE SCHEDULED TO BE REMOVED. PATCH AND REPAIR AFFECTED AREAS, INCLUDING BUT NOT LIMITED TO WALLS, FLOORS AND CEILINGS AS REQUIRED MATCHING EXISTING FINISH MATERIALS, UNO. DEMOLISH AND DISPOSE OF EXISTING WALL MOUNTED SINK. PATCH AND REPAIR AFFECTED AREAS, INCLUDING BUT NOT LIMITED TO WALLS, FLOORS AND CEILINGS AS REQUIRED MATCHING EXISTING FINISH MATERIALS, UNO. CO U- 00 I I Li -Iwo NE, EXISTING FIXTURES SCHEDULED TO BE REMOVED AS REQUIRED FOR INSTALLATION OF NEW FLOORING, THEN REINSTALLED. REFER TO NEW FLOOR PLAN FOR FURTHER REQUIREMENTS. PROTECT DURING CONSTRUCTION. EXISTING TUBE STEEL COLUMN SCHEDULED TO REMAIN. EXISTING BEARING WALL. REMOVE STUDS BELOW OPENING. HEADER TC REMAIN. EXISTING SHELF SCHEDULED TO BE REMOVED DEMOLISH ELECTRICAL, LOW VOLTAGE AND LIFE SAFETY EQUIPMENT/DEVICES (INCLUDING LOW VOLTAGE CABUNG) AS REQUIRED DUE TO DEMOLITION. AT LOCATIONS WHERE ELECTRICAL IS TO BE REMOVED, TERMINATE WIRING AT CLOSEST JUNCTION BOX OR DEMOLISH WIRING BACK TO PANEL. EXISTING HANDRAILS SCHEDULED TO REMAIN. EXISTING BEARING WALL SCHEDULED TO REMAIN. ALL STUBBED UP PIFES AND FLOOR SINKS TO BE REMOVED AS REQUIRED FOR NEW BUILDOUT. PATCH CONCRETE FLOOR AS REQUIRED. 6 L (0 110 Demolition Notes: 8. NO EXISTING SMOKE DETECTOR, PUBLIC ADDRESS SPEAKER, FIRE ALARM 1. OBTAIN DEMOLITION PERMITS AND INCLUDE ALL COSTS OF SAME IN BOX OR SIMILAR DEVICE, INCLUDING THE ASSOCIATED WIRING SHALL BE CONTRACT PRICE. DAMAGED DURING DEMOLITION AND SUBSEQUENT CONSTRUCTION. RELOCATION OF SMOKE DETECTORS, PUBLIC ADDRESS SPEAKERS AND 2. FURNISH ALL LABOR AND MATERIALS/EQUIPMENT TO COMPLETE FIRE ALARM EQUIPMENT, NECESSITATED BY NEW CONSTRUCTION, SHALL DEMOLITION AND REMOVAL OF ALL ITEMS AS INDICATED. BE ACCOMPLISHED AS A FIRST PRIORITY, AND PER THE PLANS. NO ACTIVE SMOKE DETECTOR SHALL BE COVERED OR OTHERWISE REMOVED 3. CONTRACTOR SHALL KEEP CONSTRUCTION AREA FREE OF DUST AND OR USED FOR OTHER THAN IT'S INTENDED PURPOSE. DEBRIS FOR THE DURATION OF CONSTRUCTION. 4. IF ANY QUESTIONS ARISE AS TO THE REMOVAL OF ANY MATERIAL, 9. REMOVAL OF ANY EQUIPMENT, CABLING SWITCHES, AND CONDUIT CLARIFY THE POINT IN QUESTION WITH THE ARCHITECT BEFORE PERTAINING -TO DATA/COMMUNICATIONS AND TELEPHONE SHALL BE PROCEEDING. VERIFIED WITH TELEPHONE COMPANIES AND TENANT. 5. AT COMPLETION OF DEMOLITION WORK, THE CONSTRUCTION AREA(S) SHALL BE LEFT IN "BROOM CLEAN' CONDITION. ALL DEBRIS AND MISCELLANEOUS MATERIAL SHALL BE REMOVED. 6. ALL DEBRIS REMOVAL SHALL BE PERFORMED IN ACCORDANCE WITH BUILDING MANAGEMENT REQUIREMENTS AND PROCEDURES. 10. REMOVE ALL EXISTING MATERIALS WHICH WOULD CAUSE RISES Of DEPRESSIONS IN NEW FLOORING SURFACE, SUCH AS FASTENERS, CORES, COVER PLATES, RESILIENT FLOOR COVERINGS, CARPET, C PAD, FLASH PATCH, CONCRETE FILL, PLYWOOD, ETC. 11. 7. AS DIRECTED BY BUILDING MANAGEMENT, ALL DOORS, FRAMES, HARDWARE, MECHANICAL ITEMS, PLUMBING FIXTURES, LIGHT FIXTURES (INCLUDING DOWN LIGHTS AND FLUORESCENT), AND SPECIAL EQUIPMENT 12. SHOWN TO BE REMOVED, SHALL BE CLEAN AND FREE OF DEFECTS, PROTECTED, SAVED AND REUSED AS DIRECTED HEREIN, OR RETURNED TO BUILDING STOCK. 13. DEMOLITION IS NOT NECESSARILY LIMITED TO WHAT IS SHOWN ON DRAWINGS. THE INTENT IS TO INDICATE THE GENERAL SCOPE OF DEMOLITION REQUIRED TO COMPLETE THE WORK IN ACCORDANCE THE CONTRACT DRAWINGS. RATED WALLS SHALL NOT BE PENETRATED UNLESS THE RATING MAINTAINED. c1q (D V) LU z CD C) M C) C: 00 (D (D- > 6 a) 01- co 'my S EATTLE :MOM MEMOPOL17AN Affflfflff C R t I D 1 T U-Nlb,�:N Southcenter Square 17250 Southcenter Blvd. Tukwila, WA 98188 DESIGN JPC DRAWN TP I MS CHECKED TP NO. 16-0699 12.22.16 PERMIT RECEIVED CITY OF TUKWILA DEC 2 2 2016 PERMIT CENTER -Fir-qt F oor Demolition FOR U I EW P`5 JTr DI COMPLIANCE Plan i',PPROVED J �N 17 2017 TH C of Tukwila BUIL)ING DIVISION I ----] — 1 , 1 DISPOSAL: -ALL DEBRIS REMOVED FROM THE SITE SHALL BE RECYCLED MUCH AS PRACTICAL AND ALLOWED BY LAW. @ 2013, JPC Architects, PLLC V) x 0 C -D C, CN V) 0 E Symbols Legend: ME== ELECTRICAL PANEL NO DESIGNATION = EXISTING D = DEMOLISH TYR El Key Notes: NO WORK THIS AREA, UNLESS OTHERWISE INDI CATED. REMOVE EXISTING STOREFRONT SYSTEM AS NECESSARY TO ACCOMMODATE NEW AUTOMATIC TELLER MACHINE. REFER TO FLOOR PLAN FOR NEW SCOPE OF WORK. DEMOLISH AND DISPOSE OF EXISTING COUNTERTOP, BACKSPLASH + SINK. PATCH AND REPAIR AFFECTED AREAS, INCLUDING BUT NOT LIMITED TO WALLS, FLOORS AND CEILINGS AS REQUIRED MATCHING EXISTING FINISH MATERIALS, UNO. EXISTING ELECTRICAL PANELS SCHEDULED TO REMAIN. EXITING TOILET PARTITIONS AND HARDWARE SCHEDULED TO BE REMOVED. PATCH AND REPAIR AFFECTED AREAS, INCLUDING BUT NOT LIMITED TO WALLS, FLOORS AND CEILINGS AS REQUIRED MATCHING EXISTING FINISH MATERIALS, UNO. DEMOLISH AND DISPOSE OF EXISTING WALL MOUNTED SINK. PATCH AND REPAIR AFFECTED AREAS, INCLUDING BUT NOT LIMITED TO WALLS, FLOORS AND CEILINGS AS REQUIRED MATCHING EXISTING FINISH MATERIALS, UNO. CO U- 00 I I Li -Iwo NE, EXISTING FIXTURES SCHEDULED TO BE REMOVED AS REQUIRED FOR INSTALLATION OF NEW FLOORING, THEN REINSTALLED. REFER TO NEW FLOOR PLAN FOR FURTHER REQUIREMENTS. PROTECT DURING CONSTRUCTION. EXISTING TUBE STEEL COLUMN SCHEDULED TO REMAIN. EXISTING BEARING WALL. REMOVE STUDS BELOW OPENING. HEADER TC REMAIN. EXISTING SHELF SCHEDULED TO BE REMOVED DEMOLISH ELECTRICAL, LOW VOLTAGE AND LIFE SAFETY EQUIPMENT/DEVICES (INCLUDING LOW VOLTAGE CABUNG) AS REQUIRED DUE TO DEMOLITION. AT LOCATIONS WHERE ELECTRICAL IS TO BE REMOVED, TERMINATE WIRING AT CLOSEST JUNCTION BOX OR DEMOLISH WIRING BACK TO PANEL. EXISTING HANDRAILS SCHEDULED TO REMAIN. EXISTING BEARING WALL SCHEDULED TO REMAIN. ALL STUBBED UP PIFES AND FLOOR SINKS TO BE REMOVED AS REQUIRED FOR NEW BUILDOUT. PATCH CONCRETE FLOOR AS REQUIRED. 6 L (0 110 Demolition Notes: 8. NO EXISTING SMOKE DETECTOR, PUBLIC ADDRESS SPEAKER, FIRE ALARM 1. OBTAIN DEMOLITION PERMITS AND INCLUDE ALL COSTS OF SAME IN BOX OR SIMILAR DEVICE, INCLUDING THE ASSOCIATED WIRING SHALL BE CONTRACT PRICE. DAMAGED DURING DEMOLITION AND SUBSEQUENT CONSTRUCTION. RELOCATION OF SMOKE DETECTORS, PUBLIC ADDRESS SPEAKERS AND 2. FURNISH ALL LABOR AND MATERIALS/EQUIPMENT TO COMPLETE FIRE ALARM EQUIPMENT, NECESSITATED BY NEW CONSTRUCTION, SHALL DEMOLITION AND REMOVAL OF ALL ITEMS AS INDICATED. BE ACCOMPLISHED AS A FIRST PRIORITY, AND PER THE PLANS. NO ACTIVE SMOKE DETECTOR SHALL BE COVERED OR OTHERWISE REMOVED 3. CONTRACTOR SHALL KEEP CONSTRUCTION AREA FREE OF DUST AND OR USED FOR OTHER THAN IT'S INTENDED PURPOSE. DEBRIS FOR THE DURATION OF CONSTRUCTION. 4. IF ANY QUESTIONS ARISE AS TO THE REMOVAL OF ANY MATERIAL, 9. REMOVAL OF ANY EQUIPMENT, CABLING SWITCHES, AND CONDUIT CLARIFY THE POINT IN QUESTION WITH THE ARCHITECT BEFORE PERTAINING -TO DATA/COMMUNICATIONS AND TELEPHONE SHALL BE PROCEEDING. VERIFIED WITH TELEPHONE COMPANIES AND TENANT. 5. AT COMPLETION OF DEMOLITION WORK, THE CONSTRUCTION AREA(S) SHALL BE LEFT IN "BROOM CLEAN' CONDITION. ALL DEBRIS AND MISCELLANEOUS MATERIAL SHALL BE REMOVED. 6. ALL DEBRIS REMOVAL SHALL BE PERFORMED IN ACCORDANCE WITH BUILDING MANAGEMENT REQUIREMENTS AND PROCEDURES. 10. REMOVE ALL EXISTING MATERIALS WHICH WOULD CAUSE RISES Of DEPRESSIONS IN NEW FLOORING SURFACE, SUCH AS FASTENERS, CORES, COVER PLATES, RESILIENT FLOOR COVERINGS, CARPET, C PAD, FLASH PATCH, CONCRETE FILL, PLYWOOD, ETC. 11. 7. AS DIRECTED BY BUILDING MANAGEMENT, ALL DOORS, FRAMES, HARDWARE, MECHANICAL ITEMS, PLUMBING FIXTURES, LIGHT FIXTURES (INCLUDING DOWN LIGHTS AND FLUORESCENT), AND SPECIAL EQUIPMENT 12. SHOWN TO BE REMOVED, SHALL BE CLEAN AND FREE OF DEFECTS, PROTECTED, SAVED AND REUSED AS DIRECTED HEREIN, OR RETURNED TO BUILDING STOCK. 13. DEMOLITION IS NOT NECESSARILY LIMITED TO WHAT IS SHOWN ON DRAWINGS. THE INTENT IS TO INDICATE THE GENERAL SCOPE OF DEMOLITION REQUIRED TO COMPLETE THE WORK IN ACCORDANCE THE CONTRACT DRAWINGS. RATED WALLS SHALL NOT BE PENETRATED UNLESS THE RATING MAINTAINED. c1q (D V) LU z CD C) M C) C: 00 (D (D- > 6 a) 01- co 'my S EATTLE :MOM MEMOPOL17AN Affflfflff C R t I D 1 T U-Nlb,�:N Southcenter Square 17250 Southcenter Blvd. Tukwila, WA 98188 DESIGN JPC DRAWN TP I MS CHECKED TP NO. 16-0699 12.22.16 PERMIT RECEIVED CITY OF TUKWILA DEC 2 2 2016 PERMIT CENTER -Fir-qt F oor Demolition FOR U I EW P`5 JTr DI COMPLIANCE Plan i',PPROVED J �N 17 2017 TH C of Tukwila BUIL)ING DIVISION I ----] — 1 , 1 DISPOSAL: -ALL DEBRIS REMOVED FROM THE SITE SHALL BE RECYCLED MUCH AS PRACTICAL AND ALLOWED BY LAW. @ 2013, JPC Architects, PLLC T 0 t .1.9 M C-� U) x M 7" C.) I IL W M E L: 1 3 SCOPE OF WORK Key Notes: NO WORK THIS AREA, UNLESS OTHERWISE INDICATED. EXISTING WINDOW AND FRAME SCHEDULED TO BE REMOVED. NOT USED. DEMOLISH ELECTRICAL, LOW VOLTAGE AND LIFE SAFETY EQUIPMENT/DEVICES (INCLUDING LOW VOLTAGE CABLING) AS REQUIRED DUE TO DEMOLITION. AT LOCATIONS WHERE ELECTRICAL IS TO BE REMOVED, TERMINATE WIRING AT CLOSEST JUNCTION BOX OR DEMOLISH WIRING BACK TO PANEL. EXISTING RAILING SCHEDULED TO BE REMAIN. EXISTING PANELS AT RAILING SYSTEM SCHEDULED TO BE REMOVED. (I A -Mezzanine Demolition Plan 1wil Scale: 1/4"=V-0" Demolition Notes: 1. OBTAIN DEMOLITION PERMITS AND INCLUDE ALL COSTS OF SAME IN CONTRACT PRICE. 2. FURNISH ALL LABOR AND MATERIALS/EQUIPMENT TO COMPLETE DEMOLITION AND REMOVAL OF ALL ITEMS AS INDICATED. 3. CONTRACTOR SHALL KEEP CONSTRUCTION AREA FREE OF DUST AND DEBRIS FOR THE DURATION OF CONSTRUCTION. 4. IF ANY QUESTIONS ARISE AS TO THE REMOVAL OF ANY MATERIAL, CLARIFY THE POINT IN QUESTION WITH THE ARCHITECT BEFORE PROCEEDING. 041 .............. 8. NO EXISTING SMOKE DETECTOR, PUBLIC ADDRESS SPEAKER, FIRE ALARM BOX OR SIMILAR DEVICE, INCLUDING THE ASSOCIATED WIRING SHALL BE DAMAGED DURING DEMOLITION AND SUBSEQUENT CONSTRUCTION. RELOCATION OF SMOKE DETECTORS, PUBLIC ADDRESS SPEAKERS AND FIRE ALARM EQUIPMENT, NECESSITATED BY NEW CONSTRUCTION, SHALL BE ACCOMPLISHED AS A FIRST PRIORITY, AND PER THE PLANS. NO ACTIVE SMOKE DETECTOR SHALL BE COVERED OR OTHERWISE REMOVED OR USED FOR OTHER THAN IT'S INTENDED PURPOSE. 9. REMOVAL OF ANY EQUIPMENT, CABLING SWITCHES, AND CONDUIT PERTAINING TO DATA/COMMUNICATIONS AND TELEPHONE SHALL BE VERIFIED WITH TELEPHONE COMPANIES AND TENANT. 10. REMOVE ALL EXISTING MATERIALS WHICH WOULD CAUSE RISES OR EXISTING HANDRAILS SCHEDULED TO REMAIN. 5. AT COMPLETION OF DEMOLITION WORK, THE CONSTRUCTION AREA(S) DEPRESSIONS IN NEW FLOORING SURFACE, SUCH AS FASTE ERB—, 70 EXISTING OPENING IN FLOOR. INFILL FLOOR AS REQUIRED BASED ON SHALL BE LEFT IN "BROOM CLEAN" CONDITION. ALL DEBRIS AND CORES, COVER PLATES, RESILIENT FLOOR COVERINGS, CARP�ET I C/ PRIOR TENANT'S DEMOLISHED VENT. MISCELLANEOUS MATERIAL SHALL BE REMOVED. PAD, FLASH PATCH, CONCRETE FILL, PLYWOOD, ETC. C �'_R\ EXISTING SINK SCHEDULED TO BE REMOVED. PATCH AND REPAIR FLOOR 6 AS REQUIRED BASED ON DEMOLITION. EXISTING OPENING IN FLOOR. INFILL FLOOR AS REQUIRED BASED ON PRIOR TENANT'S DEMOLISHED DUMBWAITER. 7. ALL DEBRIS REMOVAL SHALL BE PERFORMED IN ACCORDANCE WITH 11. BUILDING MANAGEMENT REQUIREMENTS AND PROCEDURES. AS DIRECTED BY BUILDING MANAGEMENT, ALL DOORS, FRAMES, HARDWARE, MECHANICAL ITEMS, PLUMBING FIXTURES, LIGHT FIXTURES (INCLUDING DOWN LIGHTS AND FLUORESCENT), AND SPECIAL EQUIPMENT 12. SHOWN TO BE REMOVED, SHALL BE CLEAN AND FREE OF DEFECTS, PROTECTED, SAVED AND REUSED AS DIRECTED HEREIN, OR RETURNED TO BUILDING STOCK. 13. A= S EATTLE, IBM METKOPOL11AN Cxtbilt U�N'fu,14 Southicenter Square 17250 Southcenter Blvd. Tukwila, WA 98188 DESIGN JPC DRAWN TP I IVIS CHECKED TP NO. 16-0699 12.22.16 PERMIT RECEIVED CITY OF TUKWILA DEC 2 2 2016 PERMIT CENTER Mezzanine Demolition 'R D 0 i?1LF1AN(CP_ Plan MED I DEMOLITION IS NOT NECESSARILY LIMITED TO WHAT IS SHOWN N DRAWINGS. THE INTENT IS TO INDICATE THE GENERAL SCOPE )F JAN 17 2017 DEMOLITION REQUIRED TO COMPLETE THE WORK IN ACCORDANCE WITH THE CONTRACT DRAWINGS. RATED WALLS SHALL NOT BE PENETRATED UNLESS THE RATING !IS City of Tukwila MAINTAINED. I BUILD&G DIVISION 1-1.2 DISPOSAL: ALL DEBRIS REMOVED FROM THE SITE SHALL BE RECYCLED AS MUCH AS PRACTICAL AND ALLOWED BY LAW. I @ 2013, JPC Architects, PLLC U 1-0 C) 04 V) Lij Z,* (3) C) C) 00 0- a) ::3 > (1) 0- b — a) A= S EATTLE, IBM METKOPOL11AN Cxtbilt U�N'fu,14 Southicenter Square 17250 Southcenter Blvd. Tukwila, WA 98188 DESIGN JPC DRAWN TP I IVIS CHECKED TP NO. 16-0699 12.22.16 PERMIT RECEIVED CITY OF TUKWILA DEC 2 2 2016 PERMIT CENTER Mezzanine Demolition 'R D 0 i?1LF1AN(CP_ Plan MED I DEMOLITION IS NOT NECESSARILY LIMITED TO WHAT IS SHOWN N DRAWINGS. THE INTENT IS TO INDICATE THE GENERAL SCOPE )F JAN 17 2017 DEMOLITION REQUIRED TO COMPLETE THE WORK IN ACCORDANCE WITH THE CONTRACT DRAWINGS. RATED WALLS SHALL NOT BE PENETRATED UNLESS THE RATING !IS City of Tukwila MAINTAINED. I BUILD&G DIVISION 1-1.2 DISPOSAL: ALL DEBRIS REMOVED FROM THE SITE SHALL BE RECYCLED AS MUCH AS PRACTICAL AND ALLOWED BY LAW. I @ 2013, JPC Architects, PLLC T U L CD cli 4j (n x Cl CD E L: 0 SCOPE OF WORK N" 1� � � � 1� 1� � � � � 1� �1111 � � SERVICE 1000 1001 COL 1003 co 1004 1007 1006 77TT"T Mm F 7,7777771,77777777W Rl� �,j * 71, � 77,!R�,F � � FIM 15'-5 1/2" 1021 0 , I Do co " I cl COFFEE cl Cl 9'-2 1/2" 1020 NJ V-2 1/2" 12'-1 1/2" ED 03 2 B P. Partition Legend: 12'-6 1/2" 1018 EXISTING SHELL & CORE WALLS NEW FULL HEIGHT PARTITION. REFER TO DETAIL 3/1-9.1. NEW CEILING HEIGHT PARTITION. REFER TO DETAIL 4/1-9.1 Symbols Legend: <&- WALL TAG 19-601 V \,Y 7'-3 1/2" CLR. C) loop 0 U 9 V-2 1/2" CO 01 Key Notes: I g; na O'k, La I Me. 0 0 ru) C) COO 53-01p V-6 1/2" 10 15 F ----J 11014 Dimension Notes: 0 ==NNW 1010 A. DO NOT SCALE DRAWINGS, WRITTEN DIMENSIONS GOVERN. ALL PARTITION 7. DIMENSIONS LOCATING DOORS ARE TO THE INSIDE EDGE OF JAMB. LOCATIONS SHALL BE AS SHOWN ON PARTITION PLAN. IN CASE OF U.N.O. CONFLICT NOTIFY ARCHITECT. PARTITION PLAN BY ARCHITECT TAKES PRECEDENCE OVER ALL OTHER PLANS. 8. "ALIGN" MEANS TO ACCURATELY LOCATE FINISHED FACES IN THE SAME PLANE. ALL PARTITIONS ARE DIMENSIONED FROM FINISH FACE OF GYPSUM BOARD TO FINISH FACE OF GYPSUM BOARD UNLESS OTHERWISE NOTED. ALL 9. ALL DOORS SHALL HAVE l'-6" CLR. ON STRIKE/PLILL SIDE AND l' -O - DIMENSIONS MARKED "CLEAR" OR "CLR" SHALL BE MAINTAINED AND CLR. ON PUSH SIDE OF DOOR. VERIFY AND ADVISE ARCHITECT OF SHALL ALLOW FOR THICKNESSES OF ALL WALL FINISHES, U.N.O. EXCEPTIONS PRIOR TO CLOSING OUT PARTITIONS. DIMENSIONS NOTED "CLEAR" OR "CLR" MUST BE ACCURATELY MAINTAINED, AND SHAI I moT vApy mnPF T14AM ± 1 /R" WITWr)HT wpmrpm NO WORK THIS AREA, UNLESS OTHERWISE INDICATED. 1. WHERE EXISTING GLASS STOREFRONT WINDOWS HAVE BEEN REMOVED, U INFILL SYSTEM AS REQUIRED TO ACCOMMODATE NEW PLAN, SALVAGE EXISTING FROM DEMOLITION AS PRACTICAL, MATCH EXISTING. WHERE PRACTICAL, NEW WALLS HAVE BEEN ALIGNED WITH OR CENTERED 2 U ON WINDOW MULLIONS, PILASTERS, EXISTING WALLS, AND/OR STRUCTURAL COLUMNS. WALLS HAVE BEEN DIMENSIONED FOR ADDITIONAL CLARITY C> C) WHEN OR WHERE EVER NECESSARY. 00 ACOUSTICALLY INSULATE AND SEAL ALL PENETRATIONS AND UNIONS > a) BETWEEN DISSIMILAR MATERIALS (INCLUDING FLOOR/CEILING PLANES, MUD 3 RINGS/JUNCTION BOXES) FULL HEIGHT X FULL LENGTH IN EXTENT AS INDICATED. AT LOCATIONS AS NECESSITATED BY 'IN -WALL: ELECTRICAL AND/OR 4 MECHANICAL SYSTEMS PROVIDE APPROPRIATE METAL STUD WIDTH TO ACCOMMODATE SIZING REQUIREMENT. CONFORM TO SPECIFIED METAL GAUGE AND SPACING AS INDICATED BY WALL TYPE. REFER TO CONSTRUCTION LEGEND FOR ADDITIONAL INFORMATION. VERIFY EXACT FRAMING REQUIREMENTS WITH TENANT'S BANK MACHINE 5 VENDOR AT ATM/ITM 1021 BEFORE FRAMING TO COMMENCE. GENERAL CONTRAClOR TO CONFIRM EXISTING WALL IS FULL HEIGHT. INSTALL 1/2" GWB ON ALL WALLS WITH DAMAGE DUE TO PREVIOUS 6 REMOVAL OF TILE/STONE. 53-01p V-6 1/2" 10 15 F ----J 11014 Dimension Notes: 0 ==NNW 1010 A. DO NOT SCALE DRAWINGS, WRITTEN DIMENSIONS GOVERN. ALL PARTITION 7. DIMENSIONS LOCATING DOORS ARE TO THE INSIDE EDGE OF JAMB. LOCATIONS SHALL BE AS SHOWN ON PARTITION PLAN. IN CASE OF U.N.O. CONFLICT NOTIFY ARCHITECT. PARTITION PLAN BY ARCHITECT TAKES PRECEDENCE OVER ALL OTHER PLANS. 8. "ALIGN" MEANS TO ACCURATELY LOCATE FINISHED FACES IN THE SAME PLANE. ALL PARTITIONS ARE DIMENSIONED FROM FINISH FACE OF GYPSUM BOARD TO FINISH FACE OF GYPSUM BOARD UNLESS OTHERWISE NOTED. ALL 9. ALL DOORS SHALL HAVE l'-6" CLR. ON STRIKE/PLILL SIDE AND l' -O - DIMENSIONS MARKED "CLEAR" OR "CLR" SHALL BE MAINTAINED AND CLR. ON PUSH SIDE OF DOOR. VERIFY AND ADVISE ARCHITECT OF SHALL ALLOW FOR THICKNESSES OF ALL WALL FINISHES, U.N.O. EXCEPTIONS PRIOR TO CLOSING OUT PARTITIONS. DIMENSIONS NOTED "CLEAR" OR "CLR" MUST BE ACCURATELY MAINTAINED, AND SHAI I moT vApy mnPF T14AM ± 1 /R" WITWr)HT wpmrpm SEATTLE VM�,mEl'ROPOLITAN AN I I W. C. k ED f T U 1410 N' Southcenter Square 17250 Southcenter Blvd. Tukwila, WA 98188 DESIGN JPC DRAWN TP I MS CHECKED TP NO. 16-0699 12.22.16 PERMIT RECEIVED CITY OF TUKWILA DEC 2 2 2016 PERMIT CENTER INSTRUCTION FROM ARCHITECT. First Floor Dimension DIMENSIONS MARKED ± MEAN A TOLERANCE NOT GREATER NOR SMALLER THAN 2 INCHES FROM INDICATED DIMENSION, U.N.O. VERIFY FIELD REVII,WED FOR Plan DIMENSIONS EXCEEDING TOLERANCE WITH THE ARCHITECT. SECURE CODE C OMPLIANCE ARCHITECT'S APPROVAL. AMIROVED NOTIFY ARCHITECT IN WRITING OF ANY DISCREPANCIES OR CONFLICTS IN JAN 1 7 2017 THE LOCATION(S) OF NEW CONSTRUCTION. UPON COMPLETION OF PARTITION LAYOUT, NOTIFY ARCHITECT. VERIFICATION OF THE LAYOUT TO BE PROVIDED BY THE ARCHITECT PRIOR TO PARTITION INSTALLATION. City :)f Tukwila 1-2,1 REFER TO REFLECTED CEILING PLANS FOR SOFFITS, CEILING HEIGHTS AND`h LV11jr BUI DIVISION] PLENUM BARRIER LOCATIONS. I @ 2013, JPC Arrhitects, PLLC U U �10 C) (N cD V) W Z.zt a) =3 C> C) C c- 00 > a) 6 01- a) co SEATTLE VM�,mEl'ROPOLITAN AN I I W. C. k ED f T U 1410 N' Southcenter Square 17250 Southcenter Blvd. Tukwila, WA 98188 DESIGN JPC DRAWN TP I MS CHECKED TP NO. 16-0699 12.22.16 PERMIT RECEIVED CITY OF TUKWILA DEC 2 2 2016 PERMIT CENTER INSTRUCTION FROM ARCHITECT. First Floor Dimension DIMENSIONS MARKED ± MEAN A TOLERANCE NOT GREATER NOR SMALLER THAN 2 INCHES FROM INDICATED DIMENSION, U.N.O. VERIFY FIELD REVII,WED FOR Plan DIMENSIONS EXCEEDING TOLERANCE WITH THE ARCHITECT. SECURE CODE C OMPLIANCE ARCHITECT'S APPROVAL. AMIROVED NOTIFY ARCHITECT IN WRITING OF ANY DISCREPANCIES OR CONFLICTS IN JAN 1 7 2017 THE LOCATION(S) OF NEW CONSTRUCTION. UPON COMPLETION OF PARTITION LAYOUT, NOTIFY ARCHITECT. VERIFICATION OF THE LAYOUT TO BE PROVIDED BY THE ARCHITECT PRIOR TO PARTITION INSTALLATION. City :)f Tukwila 1-2,1 REFER TO REFLECTED CEILING PLANS FOR SOFFITS, CEILING HEIGHTS AND`h LV11jr BUI DIVISION] PLENUM BARRIER LOCATIONS. I @ 2013, JPC Arrhitects, PLLC I 0 Z SCOPE OF WORK 000 "7TAF7 & A—L — "W IF **,%% ft� � � � � � � � � � � � � � � � � � � � � wommew 0000 a. CONSTRUCTION LEGEND FOR ADDITIONAL INFORMATION. Dimension Notes: Mezzanine Dimension Plan Scale: 1/4"=l'—O" 1. DO NOT SCALE DRAWINGS, WRITTEN DIMENSIONS GOVERN. ALL PARTITION LOCATIONS SHALL BE AS SHOWN ON PARTITION PLAN. IN CASE OF CONFLICT NOTIFY ARCHITECT. PARTITION PLAN BY ARCHITECT TAKES PRECEDENCE OVER ALL OTHER PLANS. 7. DIMENSIONS LOCATING DOORS ARE TO THE INSIDE EDGE OF JAMB. U.N.O. 8. "ALIGN" MEANS TO ACCURATELY LOCATE FINISHED FACES IN THE SAME PLANE. 2. ALL PARTITIONS ARE DIMENSIONED FROM FINISH FACE OF GYPSUM BOARD TO FINISH FACE OF GYPSUM BOARD UNLESS OTHERWISE NOTED. ALL 9. ALL DOORS SHALL HAVE V-15" CLR. ON STRIKE/PULL SIDE AND 1'-0" DIMENSIONS MARKED "CLEAR" OR "CLR" SHALL BE MAINTAINED AND CLR. ON PUSH SIDE OF DOOR. VERIFY AND ADVISE ARCHITECT OF SHALL ALLOW FOR THICKNESSES OF ALL WALL FINISHES, U.N.O. EXCEPTIONS PRIOR TO CLOSING OUT PARTITIONS. 3. DIMENSIONS NOTED "CLEAR" OR "CLR" MUST BE ACCURATELY MAINTAINED, AND SHALL NOT VARY MORE THAN ± 1/8" WITHOUT WRITTEN INSTRUCTION FROM ARCHITECT. 4. DIMENSIONS MARKED ± MEAN A TOLERANCE NOT GREATER NOR SMALLER THAN 2 INCHES FROM INDICATED DIMENSION, U.N.O. VERIFY FIELD DIMENSIONS EXCEEDING TOLERANCE WITH THE ARCHITECT. SECURE ARCHITECT'S APPROVAL. INFILL WALL TO MATCH EXISTING ADJACENT CONDITIONS. 5. INSTALL NEW TRIM TO MATCH EXISTING WHERE MISSING OR DAMAGED. 0 6. E L: 1 .2 1 1 1 NOTIFY ARCHITECT IN WRITING OF ANY DISCREPANCIES OR CONFLICTS IN THE LOCATION(S) OF NEW CONSTRUCTION. UPON COMPLETION OF PARTITION LAYOUT, NOTIFY ARCHITECT. VERIFICATION OF THE LAYOUT TO BE PROVIDED BY THE ARCHITECT PRIOR TO PARTITION INSTALLATION. - REFER TO REFLECTED CEILING PLANS FOR SOFFITS, CEILING HEIGHTS AND PLENUM BARRIER LOCATIONS. Partition Legend: Key Notes: U pwlgrllw� EXISTING SHELL & CORE WALLS (1) NO WORK THIS AREA, UNLESS OTHERWISE INDICATED. NEW FULL HEIGHT PARTITION. REFER TO DETAIL INFILL FLOOR AS REQUIRED BASED ON PRIOR TENANT'S DEMOLITION C; C> c1q WORK. c� M NEW CEILING HEIGHT PARTITION. REFER TO DETAIL WHERE PRACTICAL, NEW WALLS HAVE BEEN ALIGNED WITH OR CENTERED cl� (D > 4/1-9.1 ON WINDOW MULLIONS, PILASTERS, EXISTING WALLS, AND/OR STRUCTURAL 17) COLUMNS. WALLS HAVE BEEN DIMENSIONED FOR ADDITIONAL CLARITY WHEN OR WHERE EVER NECESSARY. Symbols Legend: ACOUSTICALLY INSULATE AND SEAL ALL PENETRATIONS AND UNIONS <�— WALL TAG BETWEEN DISSIMILAR MATERIALS (INCLUDING FLOOR/CEILING PLANES, MUD RINGS/JUNCTION BOXES) FULL HEIGHT X FULL LENGTH IN EXTENT AS 01 INDICATED. AT LOCATIONS AS NECESSITATED BY 'IN—WALL7 ELECTRICAL AND/OR MECHANICAL SYSTEMS PROVIDE APPROPRIATE METAL STUD WIDTH TO ACCOMMODATE SIZING REQUIREMENT. CONFORM TO SPECIFIED METAL GAUGE AND SPACING AS INDICATED BY WALL TYPE. REFER TO a. CONSTRUCTION LEGEND FOR ADDITIONAL INFORMATION. Dimension Notes: Mezzanine Dimension Plan Scale: 1/4"=l'—O" 1. DO NOT SCALE DRAWINGS, WRITTEN DIMENSIONS GOVERN. ALL PARTITION LOCATIONS SHALL BE AS SHOWN ON PARTITION PLAN. IN CASE OF CONFLICT NOTIFY ARCHITECT. PARTITION PLAN BY ARCHITECT TAKES PRECEDENCE OVER ALL OTHER PLANS. 7. DIMENSIONS LOCATING DOORS ARE TO THE INSIDE EDGE OF JAMB. U.N.O. 8. "ALIGN" MEANS TO ACCURATELY LOCATE FINISHED FACES IN THE SAME PLANE. 2. ALL PARTITIONS ARE DIMENSIONED FROM FINISH FACE OF GYPSUM BOARD TO FINISH FACE OF GYPSUM BOARD UNLESS OTHERWISE NOTED. ALL 9. ALL DOORS SHALL HAVE V-15" CLR. ON STRIKE/PULL SIDE AND 1'-0" DIMENSIONS MARKED "CLEAR" OR "CLR" SHALL BE MAINTAINED AND CLR. ON PUSH SIDE OF DOOR. VERIFY AND ADVISE ARCHITECT OF SHALL ALLOW FOR THICKNESSES OF ALL WALL FINISHES, U.N.O. EXCEPTIONS PRIOR TO CLOSING OUT PARTITIONS. 3. DIMENSIONS NOTED "CLEAR" OR "CLR" MUST BE ACCURATELY MAINTAINED, AND SHALL NOT VARY MORE THAN ± 1/8" WITHOUT WRITTEN INSTRUCTION FROM ARCHITECT. 4. DIMENSIONS MARKED ± MEAN A TOLERANCE NOT GREATER NOR SMALLER THAN 2 INCHES FROM INDICATED DIMENSION, U.N.O. VERIFY FIELD DIMENSIONS EXCEEDING TOLERANCE WITH THE ARCHITECT. SECURE ARCHITECT'S APPROVAL. INFILL WALL TO MATCH EXISTING ADJACENT CONDITIONS. 5. INSTALL NEW TRIM TO MATCH EXISTING WHERE MISSING OR DAMAGED. 0 6. E L: 1 .2 1 1 1 NOTIFY ARCHITECT IN WRITING OF ANY DISCREPANCIES OR CONFLICTS IN THE LOCATION(S) OF NEW CONSTRUCTION. UPON COMPLETION OF PARTITION LAYOUT, NOTIFY ARCHITECT. VERIFICATION OF THE LAYOUT TO BE PROVIDED BY THE ARCHITECT PRIOR TO PARTITION INSTALLATION. - REFER TO REFLECTED CEILING PLANS FOR SOFFITS, CEILING HEIGHTS AND PLENUM BARRIER LOCATIONS. Amy S EATTLE 'TM- P,�ETROPOLITAN ANINIAWCRE'DifT U1`4 . 10,R Southicenter Square 172.50 Southcenter Blvd. Tukwila, WA 98188 DESIGN JPC DRAWN TP I MS CHECKED TP NO. 16-0699 12.22.16 PERMIT RECEIVED CITY OF TUKWILA DEC 2 2 2016 PERMIT CENTER Mezzanine Dimension REVIEV\ff , D FOR CODE COWLIANCE APIPW I` WED JAN 1 2917 A 4 ll, city of' alli Sm. , , qr— X, BUILDINC Plan @ 2013, JPC Architects, PLLC U Uj C> c1q Uj Z,j- C) C) CC) 4-J (D > 6 ON 0) M Amy S EATTLE 'TM- P,�ETROPOLITAN ANINIAWCRE'DifT U1`4 . 10,R Southicenter Square 172.50 Southcenter Blvd. Tukwila, WA 98188 DESIGN JPC DRAWN TP I MS CHECKED TP NO. 16-0699 12.22.16 PERMIT RECEIVED CITY OF TUKWILA DEC 2 2 2016 PERMIT CENTER Mezzanine Dimension REVIEV\ff , D FOR CODE COWLIANCE APIPW I` WED JAN 1 2917 A 4 ll, city of' alli Sm. , , qr— X, BUILDINC Plan @ 2013, JPC Architects, PLLC T C) c; 0 M C3 m E A 10000 END - SCOPE OF WORK � � � � � � m SERVICE NO WORK THIS AREA, UNLESS OTHERWISE INDICATED. FIRE EXTINGUISHER CABINET (F.E.C.) (NEW AND/OR RELOCATED). COORDINATE CORE DRILL LOCATION WITH TWENTY FOUR 7. U COL[7 COL0j'TION Fmmm NOT USED IMI, 1-0 C) c1q PROVIDE BLOCKING BEHIND GW13 FOR WALL -MOUNTED DISPLAY, V) Uj z (D =) C) C) C W01 00 - PROVIDE BLOCKING BEHIND GWB FOR WALL -MOUNTED T.F.T.I. MONITOR. W > TEMPERED SAFETY GLAZING. REFERENCE SECTION 2406 OF THE 2015 0- 6 0- m VERIFY MOUNTING HEIGHT WITH AV VENDOR, INTERNATIONAL BUILDING CODE (I.B.C.) FOR GENERAL REQUIREMENTS FOR PROVIDE BLOCKING BEHIND GWB FOR T.F.T.I. EQUIPMENT. CONTRACTOR PROVIDE BLOCKING BEHIND GWB FOR COAT HOOKS AT +60"-66"AFF. ,SIT 11,01— 1 cp 1021 SEE SHEET 1-4.0 FOR PLUMBING SCHEDULE AND APPLIANCE + EQUIPMENT SCHEDULE C90D 1, `___1 0 Symbols Legend: F.E.C. BUILDING STANDARD FIRE EXTINGUISHER CABINET (OR SPEC) DUPLEX RECEPTACLE DEDICATED DUPLEX RECEPTACLE GFI DUPLEX RECEPTACLE DEDICATED FOURPLEX RECEPTACLE SPECIAL RECEPTACLE CORE DRILL J -BOX 4 VOICE/DATA RECEPTACLE. CONTRACTOR TO PROVIDE MUD RING AND PULL STRING PROXIMITY CARD READER N = NEW &/OR RELOCATED (COORDINATE RELOCATED ITEMS W/ARCHITECT) 70im (4 I �jc) D rlfi�t_1103 U 03 C) T 03 (TI) 16 @ SEATTLE NIM METRbPOLITAN =1 C R El D 1. T Vx Nf�o t4 Southcenter Square 17250 Southcenter Blvd. Tukwila, WA 98188 LO TECH CLOSET 10199CE] C CE COL AT�IOJN CO = COE W - OM FEA Orl OE1 8� rl 0 127 �1 016 rl 0 1 M5� 10, 4ff- Key Notes: NO WORK THIS AREA, UNLESS OTHERWISE INDICATED. FIRE EXTINGUISHER CABINET (F.E.C.) (NEW AND/OR RELOCATED). COORDINATE CORE DRILL LOCATION WITH TWENTY FOUR 7. U PROVIDE IDENTIFICATION SIGNAGE AT EACH EXTINGUISHER LOCATION AS Fmmm NOT USED REQUIRED. REFER TO 9/1-9.1 FOR MOUNTING HEIGHTS. 1-0 C) c1q PROVIDE BLOCKING BEHIND GW13 FOR WALL -MOUNTED DISPLAY, V) Uj z (D =) C) C) C W01 00 - PROVIDE BLOCKING BEHIND GWB FOR WALL -MOUNTED T.F.T.I. MONITOR. W > TEMPERED SAFETY GLAZING. REFERENCE SECTION 2406 OF THE 2015 0- 6 0- m SEATTLE NIM METRbPOLITAN =1 C R El D 1. T Vx Nf�o t4 Southcenter Square 17250 Southcenter Blvd. Tukwila, WA 98188 LO TECH CLOSET 10199CE] C CE COL AT�IOJN CO = COE W - OM FEA Orl OE1 8� rl 0 127 �1 016 rl 0 1 M5� 10, 4ff- Key Notes: �p PROVIDE AND INSTALL NEW PLASTIC LAMINATE TOILET PARTITIONS. EXISTING STAIRS MEET CODE REQUIREMENTS. HANDRAILS ARE MOUNTED AT 34" A.F.F. AND COMPLY WITH CODE. EXISTING HAND RAIL EXTENDS 12" BEYOND STAIR. 12.22.16 PERMIT RECEIVED CITY OF TUKWILA DEC 2 2 2016 PERMIT CENTER REVIEWED FOR CODE =1 IPLIANCE irst Floor Plan APPROVED JAN I ' 2017 NO WORK THIS AREA, UNLESS OTHERWISE INDICATED. FIRE EXTINGUISHER CABINET (F.E.C.) (NEW AND/OR RELOCATED). COORDINATE CORE DRILL LOCATION WITH TWENTY FOUR 7. PROVIDE IDENTIFICATION SIGNAGE AT EACH EXTINGUISHER LOCATION AS NOT USED REQUIRED. REFER TO 9/1-9.1 FOR MOUNTING HEIGHTS. PROVIDE BLOCKING BEHIND GW13 FOR WALL -MOUNTED DISPLAY, PROVIDED AND INSTALLED BY TWENTY FOUR 7. VERIFY MOUNTING PROVIDE BLOCKING BEHIND GWB FOR WALL -MOUNTED T.F.T.I. MONITOR. TEMPERED SAFETY GLAZING. REFERENCE SECTION 2406 OF THE 2015 HEIGHT WITH TWENTY FOUR 7. VERIFY MOUNTING HEIGHT WITH AV VENDOR, INTERNATIONAL BUILDING CODE (I.B.C.) FOR GENERAL REQUIREMENTS FOR PROVIDE BLOCKING BEHIND GWB FOR T.F.T.I. EQUIPMENT. CONTRACTOR PROVIDE BLOCKING BEHIND GWB FOR COAT HOOKS AT +60"-66"AFF. GLASS. TO ATTACH EQUIPMENT TO WALL WITH I BOLT AND CABLE. SEE DETAIL 2/1-9.3. NEW BANKING EQUIPMENT, INCLUDING ATM MACHINE AND NIGHT DROP PROVIDE AND INSTALL A SECURITY PANEL AT WORK ROOM 1015. ANCILLARY FURNITURE, FIXTURES AND EQUIPMENT T.F.T.I. INCLUDING, BUT BOX. G.C. TO PROVIDE SUPPORT PLATFORM AS REQUIRED. SEE DIEBOLD PLANNING AND SITE PREPARATION GUIDE. PROVIDE POWER AS REQUIRED, EXACT LOCATION TO BE COORDINATED WITH TENANT'S TECH TEAM. NOT LIMITED TO TABLES, CHAIRS AND NON -IDENTIFIED MILLWORK. COORDINATE POWER REQUIREMENTS WITH DIEBOLD INSTALLATION/SERVICE WALL MOUNTED SERVER RACK AND VERTICALLY MOUNTED SECURITY PROVIDE FILTERED WATER LINE FOR PLUMBED COFFEE MAKER AT COFFEE AT 1.800.999.3600. CONTACT SEATTLE METROPOLITAN CREDIT UNION CAMERA DVR, PROVIDED AND INSTALLED BY TENANT. VERIFY EXACT BAR 1002 AND BREAK ROOM 1015. VERIFY EXACT REQUIREMENTS WITH FACILITY MANAGER ROBIN BLEEKER 206.398.5591 WITH ADDITIONAL POWER AND DATA NEEDS WITH TENANT'S TECH TEAM. MFR SPECIFICATIONS. QUESTIONS. NOT USED COPY MACHINE/PRINTER (T.F.T.I.) WITH (4) SINGLE GANG MUD RINGS (1) WALL MOUNTED 4'-0' X 6'-0' X 5/8' FIRE RESISTANT PLYWOOD (WITH PULL STRING) AND (1) 110V DEDICATED DUPLEX OULTET. TERMINATION BOARD AT ATM/ITM 1021. COORDINATE EXACT REQUIREMENTS PROVIDE POWER AT BUILDING EXTERIOR FOR SIGNAGE. DESIGN AND COORDINATE CIRCUIT/AMP AND JACK/RECEPTACLE REQUIREMENTS WITH WITH DIEBOLD, TENANT'S VENDOR. LOCATION TO BE DETERMINED. TENANT. REFER TO ELECTRICAL DESIGN -BUILD DOCUMENTS FOR �g CONTRACTOR TO PROVIDE IN -WALL BLOCKING FOR NEW GRAB BARS. PROVIDE BLOCKING BEHIND GWB FOR METAL 'CHALKBOARD' PANELS, ADDITIONAL INFORMATION. PROVIDED AND INSTALLED BY TWENTY FOUR 7. PROVIDE AND INSTALL CARD READER SYSTEM. THE SYSTEM SHOULD DEMOUNTABLE WALL SYSTEM WITH INTEGRAL SLIDING DOORS. GENERAL AUTOMATIC TELLER MACHINE SIGNAGE, PROVIDED AND INSTALLED BY ALLOW FREE EGRESS FROM THE BUILDING AT ALL TIMES AS REQUIRED BY CONTRACTOR TO PROVIDE ALL REQUIRED BACKING, BLOCKING AND/OR TENANT. DESIGN AND LOCATION TO BE DETERMINED. CODE. ELECTRICAL DESIGN -BUILD CONTRACTOR TO COORDINATE WITH ANCHORAGES. COORDINATE WITH ANGELA THOMLINSON; CATALYST EXISTING ELECTRICAL PANEL SCHEDULED TO REMAIN. TENANT'S SECURITY VENDOR AS NECESSARY TO PROVIDE A FULLY WORKPLACE ACTIVATION PH: 206.465.,9973 AS REQUIRED. FUNCTIONAL AND OPERATING SYSTEM. SIGNAGE TO BE HARDWIRED. CONTRACTOR TO VERIFY EXACT POWER Kg BUILT IN BENCH. SEE DETAIL 1/1-9.3. REQUIREMENTS AND LOCATION WITH TWENTY FOUR 7. �p PROVIDE AND INSTALL NEW PLASTIC LAMINATE TOILET PARTITIONS. EXISTING STAIRS MEET CODE REQUIREMENTS. HANDRAILS ARE MOUNTED AT 34" A.F.F. AND COMPLY WITH CODE. EXISTING HAND RAIL EXTENDS 12" BEYOND STAIR. 12.22.16 PERMIT RECEIVED CITY OF TUKWILA DEC 2 2 2016 PERMIT CENTER REVIEWED FOR CODE =1 IPLIANCE irst Floor Plan APPROVED JAN I ' 2017 6 0 M M 0) C> V) EL C < C4 n E 0 SCOPE OF WORK 7TAF7 SEE SHEET 1-4.0 FOR PLUMBING SCHEDULE AND APPLIANCE + EQUIPMENT SCHEDULE IF Symbols Legend: Mezzanine Floor Plan Scale: 1/4"=l'—O" F.E.C. =1 BUILDING STANDARD FIRE EXTINGUISHER CABINET (OR SPEC) DUPLEX RECEPTACLE DEDICATED DUPLEX RECEPTACLE GFI DUPLEX RECEPTACLE DEDICATED FOURPLEX RECEPTACLE SPECIAL RECEPTACLE CORE DRILL J—BOX 4 VOICE/DATA RECEPTACLE. CONTRACTOR TO PROVIDE MUD RING AND PULL STRING PROXIMITY CARD READER N = NEW &/OR RELOCATED (COORDINATE RELOCATED ITEMS W/ARCHITECT) Key Notes: A= IS EAT T LE METKOPOLITAN C Rl b I. t U-,,:N,:!.O N Southcenter Square 17250 Southcenter Blvd. Tukwila, WA 98188 DESIGN JPC DRAWN TP I MS CHECKED TP NO. 16-0699 NO WORK THIS AREA, UNLESS OTHERWISE INDICATED. ANCILLARY FURNITURE, FIXTURES AND EQUIPMENT T.F.T.I. INCLUDING, BUT NOT LIMITED TO TABLES, CHAIRS AND NON—IDENTIFIED MILLWORK. PROVIDE BLOCKING BEHIND GWB FOR WALL—MOUNTED T.F.T.I. MONITOR. VERIFY MOUNTING HEIGHT WITH AV VENDOR. FIRE EXTINGUISHER CABINET (F.E.C.) (NEW AND/OR RELOCATED). PROVIDE IDENTIFICATION SIGNAGE AT EACH EXTINGUISHER LOCATION AS REQUIRED. REFER TO 9/1-9.1 FOR MOUNTING HEIGHTS. COORDINATE CORE DRILL LOCATION WITH ARCHITECT AND FURNITURE JURISDICTION VENDOR. PROVIDE FILTERED WATER LINE FOR PLUMBED COFFEE -MAKER AT STAFF BREAK 2001. VERIFY EXACT REQUIREMENTS WITH MFR SPLEC� G FTy PROVIDE NEW TEMPERED SAFETY GLAZING IN EXISTING RAI IN ggff_ ) FO REFERENCE SECTION 2406 OF THE 2015 INTERNATIONAL j'LQQISEr06E'M )LIANCE r M (I.B.C.) FOR GENERAL REQUIREMENTS FOR GLASS. APPROJED JAN 1712017 City 0 BUILDING 12.22.16 PERMIT RECEIVED CITY OF TUKWILA DEC 2 2 2016 PERMIT CENTER anine Floor Plan @ 2013, JPC Architects, PLLC U Uj F-0- U ._0 C) C*4 LU z C) C) 00 01 C*4 (1) > (1) MMM) 01 - ON M A= IS EAT T LE METKOPOLITAN C Rl b I. t U-,,:N,:!.O N Southcenter Square 17250 Southcenter Blvd. Tukwila, WA 98188 DESIGN JPC DRAWN TP I MS CHECKED TP NO. 16-0699 NO WORK THIS AREA, UNLESS OTHERWISE INDICATED. ANCILLARY FURNITURE, FIXTURES AND EQUIPMENT T.F.T.I. INCLUDING, BUT NOT LIMITED TO TABLES, CHAIRS AND NON—IDENTIFIED MILLWORK. PROVIDE BLOCKING BEHIND GWB FOR WALL—MOUNTED T.F.T.I. MONITOR. VERIFY MOUNTING HEIGHT WITH AV VENDOR. FIRE EXTINGUISHER CABINET (F.E.C.) (NEW AND/OR RELOCATED). PROVIDE IDENTIFICATION SIGNAGE AT EACH EXTINGUISHER LOCATION AS REQUIRED. REFER TO 9/1-9.1 FOR MOUNTING HEIGHTS. COORDINATE CORE DRILL LOCATION WITH ARCHITECT AND FURNITURE JURISDICTION VENDOR. PROVIDE FILTERED WATER LINE FOR PLUMBED COFFEE -MAKER AT STAFF BREAK 2001. VERIFY EXACT REQUIREMENTS WITH MFR SPLEC� G FTy PROVIDE NEW TEMPERED SAFETY GLAZING IN EXISTING RAI IN ggff_ ) FO REFERENCE SECTION 2406 OF THE 2015 INTERNATIONAL j'LQQISEr06E'M )LIANCE r M (I.B.C.) FOR GENERAL REQUIREMENTS FOR GLASS. APPROJED JAN 1712017 City 0 BUILDING 12.22.16 PERMIT RECEIVED CITY OF TUKWILA DEC 2 2 2016 PERMIT CENTER anine Floor Plan @ 2013, JPC Architects, PLLC I C) z U, 6 A �2 C) C4 E 0 L: M RCP Legend: Plumbing Schedule: Provided and Installed by Contractor, UNO Finish Specifications �10 CD a) :t� =3 V) Uj z 'zt (D C) =3 C) C: 00 a) > < C_ 4-j > 6 W 01- C0 RCP Legend: ITEM DESCRIPTION FLOORING CPT TYPICAL FLOORING, U.N.O. 1 MFR: THE MOHAWK GROUP - BIGELOW STYLE NAME: VANDAL TILE STYLE NO: BT358 COLOR NAME: ROUST ABOUT COLOR NO: 983 BACKING: PER MANUFACTURERS RECOMMENDATION INSTALLATION: QUARTER TURN MFR REP.: JULIA GUTT 206.409.3491 julia-gutt@mohawkind.com CPT TYPICAL FLOORING, U.N.O. 2 MFR: THE MOHAWK GROUP - BIGELOW STYLE NAME: WHIP STITCH - BROADLOOM STYLE NO: BC376/BQ376 COLOR NAME: WRAPPED SHIBORI COLOR NO: 983 BACKING: PER MANUFACTURERS RECOMMENDATION MFR REP.: JULIA GUTT 206.409.3491 julia-gutt@mohawkind.com WD 1 WOOD FLOORING MFR: TERRAMAI STYLE NAME: TEAK ENGINEERED FIP - BLACK OIL INSTALLATION: NO ADJACENT SEAMS TO ALIGN MFR REP.: TASHAWNA NASH 206.450.6712 tnash@terramai.com WOOD WALL PANELING rW_D'� WOOD FLOORING MFR: TERRAMAI STYLE NAME: TEAK ENGINEERED FIP - BLACK OIL INSTALLATION: NO ADJACENT SEAMS TO ALIGN MFR REP.: TASHAWNA NASH 206.450.6712 tnash@terramai.com WALL TILE pff­q FROM SEATTLE METROPOLITAN CREDIT UNION'S STOCK. COORDINATE PROCUREMENT OF TILE WITH SMCU. SPECIFICATION PROVIDED BELOW FOR REVERENCE ONLY. MFR: STATEMENTS TILE AND STONE STYLE NAME: MOSAICO +, VETRINA COLOR NO: VG.0426 GROUT: TEC - MIST, 939 NOTE: WHERE OUTLETS OCCUR ON THIS TILE, OUTLET COVERS TO BE WHITE. SPECIALITY WALLS TACK BOARD MFR: WALL TALKERS STYLE NAM E: TAC WALL STYLE NO: C250-02 COLOR NAME: CHARCOAL NOTE: PROVIDE STAINLESS STEEL JCAP AT EXPOSED EDGES $ SWITCH A SINK: MFR: ELKAY MODEL: LR -1720 SINGLE -BOWL SELF -RIMMING SINK SIZE: 17"W X 201 X 7-5/8" BOWL DEPTH DEPTH: 18 -GAUGE STAINLESS STEEL FAUCET: MFR: KOHLER MODEL: #K-10416 FORTE REMOTE VALVE FAUCET WITH SPRAYER INSTALL: TWO -HOLE INSTALLATION FINISH: POLISHED CHROME SOAP DISPENSER: MFR: DELTA MODEL: #RP1001 FINISH: CHROME HOTZCOLD-TAP: MFR: INSINKERATOR MODEL: #F-HC3300 INDULGE MODERN W/SS TANK AND #F -1000S FILTER FINISH: POLISHED CHROME I 101 COOPER- SURE -LITE CEILING MOUNTED EXIT SIGN - APXEL, GREEN LETTERS CEILING -MOUNTED EXHAUST FAN - VERIFY CFM REQUIREMENTS PER PLAN CEILING MOUNTED POWER E=I< SECURITY CAMERA CEILING MOUNTED DATA <9> SINK: MFR: KOHLER MODEL: #K-2196-1 PENNINGTON DROP-IN SINK SIZE: 20-1/4" L X 17-1/2"W X 8"D COLOR: WHITE FAUCET: MFR: KOHLER MODEL: #K-45800 ALTEO SINGLE -HANDLE FAUCET W/O ESCUTCHEON PLATE FINISH: POLISHED CHROME NOTE: SINGLE -HOLE INSTALLATION SOAP DISPENSER MFR: DELTA ACT -1 ARMSTRONG ULTIMA BEVELED TEGULAR 1912, 24" X 24" INSTALLED WITH 9/16" GRID. ACT -2 ARMSTRONG DUNE, 24" X 48", SQUARE LAY IN, 1773 INSTALLED WITH 15/16" GRID. MODEL: #RP1001 FINISH: CHROME FSV­1 LINOLEUM - LIJ MFR: ARMSTRONG SERIES: LINOART LINOLEUM - RHYTHMICS SHEET COLOR NAME: BLACK KNIGHT COLOR NO: LS602 SC POLISHED AND SEALED CONCRETE 1 LEVEL 3, 800 GRIT POLISHED AND GROUND SURFACE WITH HARDENED AND SEALED FINISH PROVIDE ON SITE MOCK-UP SAMPLE FOR ARCHITECTS REVIEW AND APPROVAL PRIOR TO COMMENCEMENT OF WORK. Al" S EATTLIE METROPOLITAN A§=CR.ED1T UNION Southcenter Square 17250 Southcenter Blvd. Tukwila, WA 98188 NOTE: CONTRACTOR TO VERIFY THAT ALL EQUIPMENT FITS PRIOR FABRICATION. ELECTRICAL DESIGN -BUILD CONTRACTOR TO COORDINATE WITH TENANT'S VENDORS AS NECESSARY TO PROVIDE A FULLY FUNCTIONAL AND OPERATING EQUIPMENT/SYSTEMS. REFER TO EQUIPMENT/APPLIANCE SPECS FOR ADDITIONAL REQUIRED F-1 0 GOTHAM 4" INCITO CYLINDER ICOCYL-35-20-4WR-LD- 40D -XX -XX -PM- WHITE CORD +WHITE CANOPY 10'-0" A.F.F. MEASUREMENT FROM BOTTOM OF FIXTURE PACIFIC LIGHTING SYSTEMS MELISSA MILLER mmiller@pacificlightingsystems.com 206.947.9995 F-2 OCL TINY PENDANT TN1-PlEC-40-MW-BAL- 1LED58/35K/277/50/DM 0 X' -X" A.F.F. MEASUREMENT FROM BOTTOM OF FIXTURE PACIFIC LIGHTING SYSTEMS MELISSA MILLER mmiller@pacificlightingsystems.com 206.947.9995 Appliance + Equipment Schedule: .****NOTE: ONE OF THESE FIXTURES IS F.O.I.C. COORDINATE WITH SMCU FOR PROCUREMENT OF FIXTURE.**** Provided & Installed by Contractor U.N.0 BASE CK) TYPICAL BASE, U.N.O. MFR: ROPPE PRODUCT: 4" HIGH CONTINUOUS COIL ROLLED RUBBER WALL BASE COLOR NAME: BLACK COLOR NO: 100 PROFILE: COVE DESIGN JPC DRAWN TP I IVIS CHECKED TP NO. 16-0699 ITEM DESCRIPTION F-3 C3 FOCAL POINT ID+ 4.5" X 4.5" LED DOWNLIGHT FLC44D-SO-1 OOOL-XX-X X -T- LC44-SQ- 1 OOOL-35 K -DN -WD -WH SEE RCP PACIFIC LIGHTING SYSTEMS MELISSA MILLER mmiller@pacificlightingsystems.com 206.947.9995 AUTOMATIC TELLER MACHINE, PROVIDED AND INSTALLED BY TENANT'S VENDOR. COPY MACHINE, PROVIDED AND INSTALLED BY TENANT. COFFEE MAKER, PROVIDED AND INSTALLED BY TENANT'S VENDOR. F-4 M FOCAL POINT ID+ 4.5" X 4.5" LED WALLWASH FLC44W-SO-100OL-XX-X X-T-LC44-SQ-1000- SEE RCP PACIFIC LIGHTING SYSTEMS MELISSA MILLER mmiller@pacificlightingsystems.com 206.947.9995 MICROWAVE MFR: GE MODEL: JES1072SHSS 35K -WW -WD -WH SIZE: 10-3/16 H X 12-3/4 D X 17-5/16 W FINISH: STAINLESS STEEL GENERAL WALL PAINT (TYPICAL U.N.O.) MFR: SHERWIN WILLIAMS COLOR NAME: PURE WHITE 1 COLOR NO: SW7005 SHEEN: EGGSHELL, SEMI -GLOSS @ WET AREAS F-5 EUREKA SKIRT 4255-URC-LED8.30-XX- DV -AC -60 -RC -WH -CFR 6'-6" A.F.F. MEASUREMENT FROM BOTTOM OF FIXTURE PACIFIC LIGHTING SYSTEMS MELISSA MILLER mmiller@pacificlightin gsystems.com 206.947.9995 F1 - .5] UNDER COUNTER REFRIGERATOR MFR: MARVEL MODEL: MA24RAS1 SIZE: 23-7/8"W X 31-1/8"H X 25-5/8" D FLAT SCREEN PANEL. PROVIDED AND INSTALLED BY TENANT. ACCENT WALLS P MATCH SMCU BRAND COLOR, PANTONE NEUTRAL BLACK, 2 T CMYK 72/66/65/77, RGB:27/27/27, HEX#1C1C1C P MATCH SMCU BRAND COLOR, PANTONE 398U, CMYK: F-6 1-0- LITHONIA LIGHTING LOW PROFILE STRIP LIGHT Z -1 -32 -XX -XX WITH HANGING CHAIN 9'-0" A.F.F. MEASUREMENT FROM BOTTOM OF FIXTURE PACIFIC LIGHTING SYSTEMS MELISSA MILLER mmiller@pacificlightingsystems.com 206.947.9995 INSTANT ISSUE MACHINE. PROVIDED AND INSTALLED BY TENANT. I.T.M. PROVIDED AND INSTALLED BY TENANT. �,V 47/27/100/5, RGB:145/153/46, HEX: #8C9437 P MATCH SMCU BRAND COLOR, PANTONE 384U, CMYK: 4 57/36/100/17, RGB:111/122/37, HEX: #707B33 63 REG I R ARC EC F-7 PRUDENTIAL LIGHTING P3900 -LED, PENDANT P3940-LED35-LO-FWA-T MW-D9-SC-UNV-XX-XX- 9'-0" A.F.F. MEASUREMENT FROM BOTTOM OF FIXTURE PACIFIC LIGHTING SYSTEMS MELISSA MILLER mmiller@pacificlightingsystems.com 0 DMO1 - FIXTURE TO BE DIMMABLE AND SUSPENDED. 206.947.9995 CASE WORK A. ERSON F HINGTON. FP ­L1] PLASTIC LAMINATE MFR: FORMICA COLOR NAME: SARUM TWILL - MATTE FINISH COLOR NO: 8827-58 LOCATION: COFFEE BAR 1014 GRAIN: VERTICAL FP—L2-] PLASTIC LAMINATE F-8 PRUDENTIAL LIGHTING P3900 -LED, PENDANT P3930-LED35-LO-FWA-T MW-D9-SC-UNV-XX-XX- DMO1 - FIXTURE TO BE DIMMABLE AND 9'-0" A.F.F. MEASUREMENT FROM BOTTOM OF FIXTURE PACIFIC LIGHTING SYSTEMS MELISSA MILLER m mil ler@pacif iclig hti ng system s.com 206.947.9995 12.22.16 PERMIT SUSPENDED. MFR: FORMICA COLOR NAME: NATURAL CANE - NATURELLE FINISH COLOR NO: 6930 -NT LOCATION: BREAK ROOM 1004 GRAIN: VERTICAL F -9A FOCAL POINT FOCUS 4, FLUORESCENT, F4W-NS-lT5-XX-XX-XX -RC-WH-48" SEE RCP PACIFIC LIGHTING SYSTEMS MELISSA MILLER mmiller@pacificlightingsystems.com 206.947.9995 FP—L3] PLASTIC LAMINATE MFR: PIONITE COLOR NAME: PEARL OF THE ORIENT COLOR NO: AG601 SUEDE LOCATION: WORK ROOM 1001 F -9B FOCAL POINT FOCUS 4, FLUORESCENT, F4W-NS-lT5-XX-XX-XX -RC-WH-96 is SEE RCP PACIFIC LIGHTING SYSTEMS MELISSA MILLER mmiller@pacificlightingsystems.com 206.947.9995 FP _L4 PLASTIC LAMINATE MFR: NEVAMAR COLOR NAME: EASY ELEGANCE COLOR NO: VA5002T LOCATION: TOILET 1002 NOTE: WHERE OUTLETS OCCUR ON THIS PLASTIC LAMINATE, OUTLET COVERS TO BE BLACK. F-10 LITHONIA, OR APPROVED EQUAL FLU. UNDERCABINET 2UC-X-T5-MVOLT- GEB101S. LAMP: 3500K SEE RCP FOR LOCATIONS AND LENGTHS. VERIFY LENGTH WITH CABINETRY PRIOR TO PLACING ORDER. PACIFIC LIGHTING SYSTEMS MELISSA MILLER mmiller@pacificlightingsystems.com 206.947.9995 _V C REC PLASTIC LAMINATE FpL5] MFR: PIONITE COLOR NAME: ICE FISHIN COLOR NO: WF181 SUEDE LOCATION: TOILET 1002 + BREAK ROOM 1004 WINDOW FILM CITY KWILA EC 2 2016 04- PERMITCENTER JURISDICTION STAMP F-11 LITHONIA LIGHTING 2x4 AVANTE DIRECT/INDIRECT LED. #2AVL4-XX-XX-30L- MDR-XX-EZ1-LP835-XX (38W) SEE RCP PACIFIC LIGHTING SYSTEMS MELISSA MILLER mmiller@pacificlightingsystems.com 206.947.9995 F-12 EUREKA MOONSET CLASSIC 3531-23-Fr5l4-XX-XX- XX -SC -WH 7'-4" A.F.F. MEASUREMENT FROM BOTTOM OF FIXTURE PACIFIC LIGHTING SYSTEMS MELISSA MILLER mmiller@pacificlightingsystems.com 206.947.9995 WF NOT USED REVIEWED FOR CODE COMPLIANCrt- Lighting + Finish KW—F MFR: 3M APPROVED Specifications STYLE: CUSTOM GRADATION INSTALLER: BROWER TINT + GRAPHIC JAN 17 2017 SIZE: PER ELEVATION City of Tukwila BUILDING DIVISION_j 11bi 3)f 1-4.0 2013, JPC Architects, PLLC Uj U) X 0- E r- --I ---- SCOPE OF WORK SERVICE COL7 COL,7 T� I 9F- 1 0 9F- 1 10'-0" 'F- 1 Y ^5%, �12 C�- <G—. W-. B-> r 9'-5" <G -.-W-. -B.) r lo, -O" 5's DTYP. 9F- 1 CO. -T. —S. > Lj.F. g, 101 C�- 9F- 1 1021 aC_T-_2> 9F- 1 8 - I YP. 9F- 1 F-8 -7 F F -7- F"8 n him 'OF -1 a F-4 1020 F-2 m IffillifyAl 0 Z. -1 9F- 1 9F- 1 4 3 5 4 TYP. 9 18 FX 10 ILI 11015 1- F-12 "F-.-3 3, G.W.R -1- 7"-10" F-12 -F"9A I F .7 F7� - EXT;' G.W.B.-' 1 oil. F -9B-, CAC -7-25 F-11 TECH CLOSET FOA 10, 4ff— Ifflil Key Notes: EGRESS LIGHTING SHALL BE DESIGNED BY A LICENSED ELECTRICAL ENGINEER BASED ON FINAL FLOOR PLAN(S) AND THE MOST CURRENT (IN FORCE) ISSUE OF THE IBC, IEC AND LOCAL CODES/ORDINANCES. THE ENGINEER MAY USE THE ARCHITECTS EGRESS MAPS (COMMON PATH OF OPEN TO STRUCTURE (OTS) CEILINGS AND EXISTING CEILING ELEMENTS TO BE PAINTED P-1. PROVIDE NEW SPIRAL DUCTWORK IN OTS AREAS. NEW DUCTWORK & NEW CONDUIT TO BE PAINTED. ANY IN -WALL TRANSFER GRILLS TO BE PAINTED TO MATCH WALLS. Reflected Ceiling Notes: NO WORK THIS AREA, UNLESS OTHERWISE INDICATED. 1. COORDINATE THE WORK OF ALL TRADES INVOLVED IN THE CEILING WORK 8. NOTIFY ARCHITECT OF ANY CONFLICTS OF LIGHT FIXTURE LOCATIONS C) CN a) A:� Uj TO ENSURE CLEARANCES FOR FIXTURES, DUCTS, PIPING, CEILING WITH MAIN RUNNERS, DUCTS, STRUCTURES, HVAC, AND/OR (E)CONDUIT, C) 00 GENERAL CONTRACTOR TO PROVIDE ALL REQUIRED BLOCKING, BRACING TRAVEL/EXIT TRAVEL DISTANCE) AS STARTING POINT FOR A BASIS OF PROVIDE EXHAUST FAN THIS ROOM. CFM TO BE BASED ON USE AND > (1) SUSPENSION SYSTEM, ETC., NECESSARY TO MAINTAIN THE FINISHED 01-_ c::) 011 PRIOR TO FRAMING FOR LIGHTS. ANY DISCREPANCIES BETWEEN AND MISC. SUPPORTS AS NECESSITATED BY THE ARCHITECTURAL, DESIGN. HOWEVER, IT SHALL REMAIN THE SOLE RESPONSIBILITY OF THE VOLUME OF ROOM. VENT PER BUILDING STANDARD REQUIREMENTS AND CEILING HEIGHTS INDICATED ON ARCHITECT'S DRAWINGS. ARCHITECT'S CEILING GRID LOCATION & ACTUAL FIELD CONDITIONS ARE MECHANICAL, ELECTRICAL AND OTHER SUBTRADES. ENGINEER TO COMPLETE A SCOPE OF WORK THAT ADDRESSES ALL LOCAL JURISDICTIONAL CODES. REFER TO MECHANICAL DESIGN -BUILD TO BE CLARIFIED WITH THE ARCHITECT PRIOR TO FRAMING. COORDINATE ALL EXPOSED ELECTRICAL, LOW VOLTAGE (WAP'S), AV, EGRESS LIGHTING I.E.; ROOMS, SPECIALIZED SPACES, PATHWAYS, ETC. PER DOCUMENTS FOR ADDITIONAL INFO. 2. PERIMETER CEILING ANGLE, WHERE OCCURS, SHALL BE INSTALLED TIGHT MECHANICAL AND LIFE SAFETY DEVICES TO AVOID CONFLICTS. LIGHTING THE AFOREMENTIONED CODES. FINAL EGRESS LIGHTING QUANTITIES AND THE INTENT AT THE OPEN TO STRUCTURE CEILING AREAS IS TO KEEP TO VERTICAL SURFACES, FREE FROM CURVES, BREAKS OR OTHER 9. SUBMIT GRILLE, THERMOSTAT, AND OTHER FIXTURE AND ELEMENT PLACEMENT TO TAKE PRIORY OVER ALL OVER DEVICES AND ABOVE LOCATIONS SHALL BE DETERMINED BY BUILDING AND FIRE INSPECTOR'S THE AREAS AS ORDERLY AS POSSIBLE. INCLUDING BUT NOT LIMITED TO IRREGULARITIES AND PAINTED TO MATCH CEILING FINISH. LAYOUTS TO THE ARCHITECT FOR REVIEW AT LEAST 2 WEEKS PRIOR TO CEILING CONFLICTS. NOTE: IT IS THE ARCHITECTS EXPECTATION THAT ALL FIELD PLACEMENT DETERMINATION. WIRING, CABLING, DUCT WORK AND SPRINKLER LINES. OPEN TO INSTALLATION. EXPOSED FIXTURES AND EQUIPMENT RUN IN CONTINUOUS PARALLEL AND SECURITY CAMERA PROVIDED AND INSTALLED BY TENANT'S SECURITY STRUCTURE ELEMENTS TO BE LAID OUT PARALLEL TO ADJACENT 3. FURNISH AND INSTALL ALL ASSOCIATED TRIM AND SEISMIC BRACING AS PERPENDICULAR ORIENTATIONS (UNLESS OTHERWISE DICTATED). VENDOR. CONTRACTOR TO PROVIDE POWER HOOK UP AS REQUIRED. SURFACES AND ALL CORNERS ARE TO BE TREATED WITH 90 DEGREE REQUIRED. 10. VERIFY FIELD CONDITIONS AND LOCATIONS OF ALL PLUMBING, COORDINATE WITH TENANT'S SECURITY VENDOR FOR EXACT POWER NEEDS. ANGLES. ALL DISCIPLINES TO COORDINATE LAYOUTS, LOCATIONS AND MECHANICAL DUCTS, STRUCTURAL ELEMENTS AND ALL OTHER RELATED M/E/P & LIFE SAFETY WORK IN EXPOSED CEILING ('OPEN TO STRUCTURE DESIGNS AS REQUIRED TO ACHIEVE THIS GOAL. COORDINATE WITH 4. LIGHT FIXTURES, NEW SPRINKLERS AND OTHER CEILING ELEMENTS SHALL ITEMS. INSTALL NEW PLUMBING, MECHANICAL, FANS, DUCTS, CONDUITS, AREAS-) SHALL BE OF THE HIGHEST QUALITY INSTALLATION AND ALL ACCESS PANELS (QUANTIFIES, SIZES, ETC.) SHALL BE SOLE DESIGN, ARCHITECTS AS REQUIRED. BE CENTERED IN THE 2'X2' SECTION OF INDIVIDUAL CEILING TILES U.N.O. AND OTHER RELATED ITEMS SO AS TO NOT CONFLICT WITH AW/ALL— WORKMANSHIP. SPIRAL DUCTING TO BE MILL FINISH, WITH TAGS AND FURNISH AND INSTALLATION RESPONSIBILITY OF THE GENERAL FIELD CONDITIONS INCLUDING LUMINAIRES. REVI CONSTRUCTION MARKS REMOVED. PLUMBING TO BE LEVEL, STRAIGHT CONTRACTOR, MEP AND LIFE SAFETY TRADES. IT IS THE INTENT OF THE ALL GWB CEILING TO BE PAINTED P-1, UNO. 5. PROVIDE CEILING ACCESS AS REQUIRED FOR EQUIPMENT AND SYSTEM AND CLEANED FREE OF CONSTRUCTION MARKS OR DEBRIS. NOTE: IT IS ARCHITECT TO MINIMIZE ACCESS PANELS IN ALL CONDITIONS. EVERY UNDERSIDE OF GWB SOFFIT TO BE PAINTED P-3 MAINTENANCE, AND MATCH ADJACENT CEILING FINISH U.N.O. 11. INSTALL NEW LIGHT FIXTURES WITH PROTECTIVE FILM OR SIMIL\p?&j1R, THE DESIGN INTENT THAT THE DUCTWORK AND VAV TYPE BOXES ARE EFFORT SHOULD BE MADE TO POSITION, GANG AND/OR RELOCATE OVER LOUVER, LENS, BAFFLE, ETC. TO AVOID FIXTURE SOILIN( OR EXPOSED, CENTRALIZED AND FEATURED WITHIN THE 'OPEN TO STRUCTURE DEVICES REQUIRING ACCESS. ACCESS PANELS SHALL CONFORM TO "LIFT PROVIDE HVAC RETURN GRILLE DIRECTLY ABOVE WALL MOUNTED SERVER 6. ALL SOFFITS AND CEILING HEIGHTS ARE DIMENSIONED FROM TOP OF DAMAGE. FIXTURES SHALL BE MAINTAINED CLEAN AND AS NEW ALL JM AREAS". INTEXFORMS & SHIFT" MODELS FOR CEILING APPLICATION AND RACK FINISHED FLOOR TO BOTTOM OF FINISHED GYPSUM BOARD OR CEILING LAMPS SHALL BE NEW AT PROJECT COMPLETION. CONFIRM ALL FLOOR AND INDIVIDUAL ROOM SWITCHING CONTROLS SIMILAR HINGED MODELS FOR WALL APPLICATIONS (INTERIOR ONLY). n17 PROVIDE AND INSTALL F-6 AT STORAGE 1007. TILE AND SHALL ALLOW FOR THICKNESS OF ALL FLOOR FINISHES. DESIGN JPC DRAWN TP I IVIS CHECKED TP NO. 16-0699 12.22.16 PERMIT RECEIVED CITY OF TUKWILA DEC 2 2 20% PERMIT CENTER First Floor Reflected WED FOR -% :)MPLIANC4...eiling Plan ROVED 17 2017 (SWITCHING, OCCUPANCY SENSORS, DIMMING CONTROLS AND ZONING) 7. ALL SPECIFIC INFORMATION CONCERNING INSTALLATION FOR VARIOUS & C i t�y Tukwila WITH ARCHITECT PRIOR TO ROUGH IN AND ORDERING OF LIGHT FIXTURES. ALL EXISTING LIGHT FIXTURES SCHEDULED TO BE REMOVED. ABOVE -CEILING ELEMENTS ARE TO BE DESIGN BUILD, DOCUMENTATION 1 -4,1 1110211 1 *.9 BUILIN 4G DIVISION CEILING MOUNTED ILLUMINATED EXIT LIGHT. FINAL EGRESS SIGNAGE BY OTHERS - PERMITTED SEPARATELY. 'D I Lc QUANTITIES AND LOCATIONS SHALL BE DETERMINED BY BUILDING AND FIRE QJ9 PATCH CEILING AS REQUIRED WHERE EXISTING WALLS WERE REMOVED INSPECTOR'S FIELD PLACEMENT DETERMINATION. REFER TO DESIGN -BUILD @ 2013, JPC Architects, PLLC C) CN a) A:� Uj C) 00 C_ 4--J > (1) 01-_ c::) 011 — a) Cn DESIGN JPC DRAWN TP I IVIS CHECKED TP NO. 16-0699 12.22.16 PERMIT RECEIVED CITY OF TUKWILA DEC 2 2 20% PERMIT CENTER First Floor Reflected WED FOR -% :)MPLIANC4...eiling Plan ROVED 17 2017 (SWITCHING, OCCUPANCY SENSORS, DIMMING CONTROLS AND ZONING) 7. ALL SPECIFIC INFORMATION CONCERNING INSTALLATION FOR VARIOUS & C i t�y Tukwila WITH ARCHITECT PRIOR TO ROUGH IN AND ORDERING OF LIGHT FIXTURES. ALL EXISTING LIGHT FIXTURES SCHEDULED TO BE REMOVED. ABOVE -CEILING ELEMENTS ARE TO BE DESIGN BUILD, DOCUMENTATION 1 -4,1 1110211 1 *.9 BUILIN 4G DIVISION CEILING MOUNTED ILLUMINATED EXIT LIGHT. FINAL EGRESS SIGNAGE BY OTHERS - PERMITTED SEPARATELY. 'D I Lc QUANTITIES AND LOCATIONS SHALL BE DETERMINED BY BUILDING AND FIRE QJ9 PATCH CEILING AS REQUIRED WHERE EXISTING WALLS WERE REMOVED INSPECTOR'S FIELD PLACEMENT DETERMINATION. REFER TO DESIGN -BUILD @ 2013, JPC Architects, PLLC I 0 Z 111 0 m ,I - Of m IL 11 C) Z :::i �:_- U < C14 E SEE SHEET 1-4.0 FOR RCP LEGEND Key Notes: NO WORK THIS AREA, UNLESS OTHERWISE INDICATED. GENERAL CONTRACTOR TO PROVIDE ALL REQUIRED BLOCKING, BRACING AND MISC. SUPPORTS AS NECESSITATED BY THE ARCHITECTURAL, MECHANICAL, ELECTRICAL AND OTHER SUBTRADES. COORDINATE ALL EXPOSED ELECTRICAL, LOW VOLTAGE (WAP'S), AV, MECHANICAL AND LIFE SAFETY DEVICES TO AVOID CONFLICTS. LIGHTING PLACEMENT TO TAKE PRIORY OVER ALL OVER DEVICES AND. ABOVE CEILING CONFLICTS. NOTE: IT IS THE ARCHITECTS EXPECTATION THAT ALL EXPOSED FIXTURES AND EQUIPMENT RUN IN CONTINUOUS PARALLEL AND PERPENDICULAR ORIENTATIONS (UNLESS OTHERWISE DICTATED). M/E/P & LIFE SAFETY WORK IN EXPOSED CEILING ('OPEN TO STRUCTURE AREAS-) SHALL BE OF THE HIGHEST QUALITY INSTALLATION AND WORKMANSHIP. SPIRAL DUCTING TO BE MILL FINISH, WITH TAGS AND CONSTRUCTION MARKS REMOVED. PLUMBING TO BE LEVEL, STRAIGHT AND CLEANED FREE OF CONSTRUCTION MARKS OR DEBRIS. NOTE: IT IS THE DESIGN INTENT THAT THE DUCTWORK AND VAV TYPE BOXES ARE EXPOSED, CENTRALIZED AND FEATURED WITHIN THE 'OPEN TO STRUCTURE AREAS". CONFIRM ALL FLOOR AND INDIVIDUAL ROOM SWITCHING CONTROLS (SWITCHING, OCCUPANCY SENSORS, DIMMING CONTROLS AND ZONING) WITH ARCHITECT PRIOR TO ROUGH IN AND ORDERING OF LIGHT FIXTURES. SCOPE OF WORK STAFF 'IF# IF %%., *� � � � � � � � � � � � 0000, (Amn First Floor Reflected Ceiling Plan C Scale: 1/4"=V -O" Reflected Ceiling Notes: 1. COORDINATE THE WORK OF ALL TRADES INVOLVED IN THE CEILING WORK 8. NOTIFY ARCHITECT OF ANY CONFLICTS OF LIGHT FIXTURE LOCATIONS TO ENSURE CLEARANCES FOR FIXTURES, DUCTS, PIPING, CEILING WITH MAIN RUNNERS, DUCTS, STRUCTURES, HVAC, AND/OR (E)CONDUIT, SUSPENSION SYSTEM, ETC., NECESSARY TO MAINTAIN THE FINISHED PRIOR TO FRAMING FOR LIGHTS. ANY DISCREPANCIES BETWEEN CEILING HEIGHTS INDICATED ON ARCHITECT'S DRAWINGS. ARCHITECT'S CEILING GRID LOCATION & ACTUAL FIELD CONDITIONS ARE TO BE CLARIFIED WITH THE ARCHITECT PRIOR TO FRAMING. 2. PERIMETER CEILING ANGLE, WHERE OCCURS, SHALL BE INSTALLED TIGHT TO VERTICAL SURFACES, FREE FROM CURVES, BREAKS OR OTHER 9. SUBMIT GRILLE, THERMOSTAT, AND OTHER FIXTURE AND ELEMENT IRREGULARITIES AND PAINTED TO MATCH CEILING FINISH. LAYOUTS TO THE ARCHITECT FOR REVIEW AT LEAST 2 WEEKS PRIOR TO INSTALLATION. 3. FURNISH AND INSTALL ALL ASSOCIATED TRIM AND SEISMIC BRACING AS REQUIRED. 4. LIGHT FIXTURES, NEW SPRINKLERS AND OTHER CEILING ELEMENTS SHALI BE CENTERED IN THE 2'X2' SECTION OF INDIVIDUAL CEILING TILES U.N.O. 5. PROVIDE CEILING ACCESS AS REQUIRED FOR EQUIPMENT AND SYSTEM MAINTENANCE, AND MATCH ADJACENT CEILING FINISH U.N.O. 6. ALL SOFFITS AND CEILING HEIGHTS ARE DIMENSIONED FROM TOP OF FINISHED FLOOR TO BOTTOM OF FINISHED GYPSUM BOARD OR CEILING TILE AND SHALL ALLOW FOR THICKNESS OF ALL FLOOR FINISHES. 7. ALL SPECIFIC INFORMATION CONCERNING INSTALLATION FOR VARIOUS ABOVE -CEILING ELEMENTS ARE TO BE DESIGN BUILD, DOCUMENTATION BY OTHERS - PERMITTED SEPARATELY. 10. VERIFY FIELD CONDITIONS AND LOCATIONS OF ALL PLUMBING, MECHANICAL DUCTS, STRUCTURAL ELEMENTS AND ALL OTHER RELATED ITEMS. INSTALL NEW PLUMBING, MECHANICAL, FANS, DUCTS, CONDUITS, AND OTHER RELATED ITEMS SO AS TO NOT CONFLICT WITH ANY/ALL FIELD CONDITIONS INCLUDING LUMINAIRES. r 11. INSTALL NEW LIGHT FIXTURES WITH PROTECTIVE FILM OR SIMILAR C, OVER LOUVER, LENS, BAFFLE, ETC. TO AVOID FIXTURE SOILING OR DAMAGE. FIXTURES SHALL BE MAINTAINED CLEAN AND AS NEW. ALL LAMPS SHALL BE NEW AT PROJECT COMPLETION. CEILING MOUNTED ILLUMINATED EXIT LIGHT. FINAL EGRESS SIGNAGE ALL ACCESS PANELS (QUANTIFIES, SIZES, ETC.) SHALL BE SOLE DESIGN, QUANTITIES AND LOCATIONS SHALL BE DETERMINED BY BUILDING AND FIRE FURNISH AND INSTALLATION RESPONSIBILITY OF THE GENERAL INSPECTOR'S FIELD PLACEMENT DETERMINATION. REFER TO DESIGN -BUILD CONTRACTOR, MEP AND LIFE SAFETY TRADES. IT IS THE INTENT OF THE ELECTRICAL FOR ADDITIONAL INFORMATION. ARCHITECT TO MINIMIZE ACCESS PANELS IN ALL CONDITIONS. EVERY C) C14 EGRESS LIGHTING SHALL BE DESIGNED BY A LICENSED ELECTRICAL EFFORT SHOULD BE MADE TO POSITION, GANG AND/OR RELOCATE ENGINEER BASED ON FINAL FLOOR PLAN(S) AND THE MOST CURRENT (IN Z a) DEVICES REQUIRING ACCESS. ACCESS PANELS SHALL CONFORM TO "LIFT FORCE) ISSUE OF THE IBC, IEC AND LOCAL CODES/ORDINANCES. THE INTEXFORMS & SHIFT" MODELS FOR CEILING APPLICATION AND 4-4 ENGINEER MAY USE THE ARCHITECTS EGRESS MAPS (COMMON PATH OF SIMILAR HINGED MODELS FOR WALL APPLICATIONS (INTERIOR ONLY). a) co TRAVEL/EXIT TRAVEL DISTANCE) AS STARTING POINT FOR A BASIS OF OPEN TO STRUCTURE (OTS) CEILINGS AND EXISTING CEILING ELEMENTS DESIGN. HOWEVER, IT SHALL REMAIN THE SOLE RESPONSIBILITY OF THE TO BE PAINTED P-1. PROVIDE NEW SPIRAL DUCTWORK IN OTS AREAS. ENGINEER TO COMPLETE A SCOPE OF WORK THAT ADDRESSES ALL NEW DUCTWORK & NEW CONDUIT TO BE PAINTED. ANY IN -WALL EGRESS LIGHTING I.E.; ROOMS, SPECIALIZED SPACES, PATHWAYS, ETC. PER TRANSFER GRILLS TO BE PAINTED TO MATCH WALLS. THE AFOREMENTIONED CODES. FINAL EGRESS LIGHTING QUANTITIES AND PROVIDE EXHAUST FAN THIS ROOM. CFM TO BE BASED ON USE AND LOCATIONS SHALL BE DETERMINED BY BUILDING AND FIRE INSPECTOR'S VOLUME OF ROOM. VENT PER BUILDING STANDARD REQUIREMENTS AND FIELD PLACEMENT DETERMINATION. LOCAL JURISDICTIONAL CODES. REFER TO MECHANICAL DESIGN -BUILD THE INTENT AT THE OPEN TO STRUCTURE CEILING AREAS IS TO KEEP DOCUMENTS FOR ADDITIONAL INFO. THE AREAS AS ORDERLY AS POSSIBLE. INCLUDING BUT NOT LIMITED TO PATCH AND REPAIR ANY DAMAGE FROM PRIOR TENANT'S GRILL VENT. WIRING, CABLING, DUCT WORK AND SPRINKLER LINES. OPEN TO STRUCTURE ELEMENTS TO BE LAID OUT PARALLEL TO ADJACENT ALL EXISTING LIGHT FIXTURES SCHEDULED TO BE REMOVED. SURFACES AND ALL CORNERS ARE TO BE TREATED WITH 90 DEGREE ANGLES. ALL DISCIPLINES TO COORDINATE LAYOUTS, LOCATIONS AND DESIGNS AS REQUIRED TO ACHIEVE THIS GOAL. COORDINATE WITH ARCHITECTS AS REQUIRED. (Amn First Floor Reflected Ceiling Plan C Scale: 1/4"=V -O" Reflected Ceiling Notes: 1. COORDINATE THE WORK OF ALL TRADES INVOLVED IN THE CEILING WORK 8. NOTIFY ARCHITECT OF ANY CONFLICTS OF LIGHT FIXTURE LOCATIONS TO ENSURE CLEARANCES FOR FIXTURES, DUCTS, PIPING, CEILING WITH MAIN RUNNERS, DUCTS, STRUCTURES, HVAC, AND/OR (E)CONDUIT, SUSPENSION SYSTEM, ETC., NECESSARY TO MAINTAIN THE FINISHED PRIOR TO FRAMING FOR LIGHTS. ANY DISCREPANCIES BETWEEN CEILING HEIGHTS INDICATED ON ARCHITECT'S DRAWINGS. ARCHITECT'S CEILING GRID LOCATION & ACTUAL FIELD CONDITIONS ARE TO BE CLARIFIED WITH THE ARCHITECT PRIOR TO FRAMING. 2. PERIMETER CEILING ANGLE, WHERE OCCURS, SHALL BE INSTALLED TIGHT TO VERTICAL SURFACES, FREE FROM CURVES, BREAKS OR OTHER 9. SUBMIT GRILLE, THERMOSTAT, AND OTHER FIXTURE AND ELEMENT IRREGULARITIES AND PAINTED TO MATCH CEILING FINISH. LAYOUTS TO THE ARCHITECT FOR REVIEW AT LEAST 2 WEEKS PRIOR TO INSTALLATION. 3. FURNISH AND INSTALL ALL ASSOCIATED TRIM AND SEISMIC BRACING AS REQUIRED. 4. LIGHT FIXTURES, NEW SPRINKLERS AND OTHER CEILING ELEMENTS SHALI BE CENTERED IN THE 2'X2' SECTION OF INDIVIDUAL CEILING TILES U.N.O. 5. PROVIDE CEILING ACCESS AS REQUIRED FOR EQUIPMENT AND SYSTEM MAINTENANCE, AND MATCH ADJACENT CEILING FINISH U.N.O. 6. ALL SOFFITS AND CEILING HEIGHTS ARE DIMENSIONED FROM TOP OF FINISHED FLOOR TO BOTTOM OF FINISHED GYPSUM BOARD OR CEILING TILE AND SHALL ALLOW FOR THICKNESS OF ALL FLOOR FINISHES. 7. ALL SPECIFIC INFORMATION CONCERNING INSTALLATION FOR VARIOUS ABOVE -CEILING ELEMENTS ARE TO BE DESIGN BUILD, DOCUMENTATION BY OTHERS - PERMITTED SEPARATELY. 10. VERIFY FIELD CONDITIONS AND LOCATIONS OF ALL PLUMBING, MECHANICAL DUCTS, STRUCTURAL ELEMENTS AND ALL OTHER RELATED ITEMS. INSTALL NEW PLUMBING, MECHANICAL, FANS, DUCTS, CONDUITS, AND OTHER RELATED ITEMS SO AS TO NOT CONFLICT WITH ANY/ALL FIELD CONDITIONS INCLUDING LUMINAIRES. r 11. INSTALL NEW LIGHT FIXTURES WITH PROTECTIVE FILM OR SIMILAR C, OVER LOUVER, LENS, BAFFLE, ETC. TO AVOID FIXTURE SOILING OR DAMAGE. FIXTURES SHALL BE MAINTAINED CLEAN AND AS NEW. ALL LAMPS SHALL BE NEW AT PROJECT COMPLETION. A'""' S EAT T L E NEM METROPOLITAN REW CREDIT UNION Southcenter Square 17250 Southcenter Blvd. Tukwila, WA 98188 DESIGN JPC DRAWN TP I MS CHECKED TP NO. 16-0699 12.22.16 PERMIT RECEIVED CITY OF TUKWILA DEC 2 2 2016 PERMITCENTER Mezzanine Reflected �_EVIEWED F )E COMPLICAP ng Plan APPROVED JAN 17 2017 City of Tukwila ILDING DIVISIJ444,2 @ 2013, JPC Architects, PLLC C) C14 V) U-1 Z a) C) 00 C_ 4-4 > 6 0%, a) co A'""' S EAT T L E NEM METROPOLITAN REW CREDIT UNION Southcenter Square 17250 Southcenter Blvd. Tukwila, WA 98188 DESIGN JPC DRAWN TP I MS CHECKED TP NO. 16-0699 12.22.16 PERMIT RECEIVED CITY OF TUKWILA DEC 2 2 2016 PERMITCENTER Mezzanine Reflected �_EVIEWED F )E COMPLICAP ng Plan APPROVED JAN 17 2017 City of Tukwila ILDING DIVISIJ444,2 @ 2013, JPC Architects, PLLC I 0 C> E SCOPE OF WORK SERVICE 1000 1001 COL 1003 ION COL 1004 ION 1007 1006 SEE SHEET 1-4.0 FOR FINISH LEGEND COFFEE M 1019CE COM 9 __] 1018 Accessories Schedule: (Provided & Installed by Contractor U.N.0) ITEM DESCRIPTION GRAB BARS MFR: BOBRICK MODEL: (ONE OF EACH) B -5806X18, B -5806X36, 8— 5806X42 F-2] TOILET TISSUE DISPENSER MFR: BOBRICK MODEL: B-4288 — SATIN FINISH STAINLESS STEEL F3-] SEAT DISPENSER MFR: BOBRICK MODEL: B-4221 — SURFACE MOUNTED F4-� AUTOMATIC HAND DRYER MFR: DYSON MODEL: AIR BLADE V FINISH: AB12 — SPRAYED NICKEL MIRROR MIRROR, MASTIC HUNG TO WALL, VERIFY SIZE PRIOR TO ORDER. SANITARY NAPKIN DISPOSAL MFR: BOBRICK MODEL: B270; STAINLESS STEEL NOTE: CONTRACTOR TO VERIFY THAT ALL ACCESSORIES FITS PRIOR FABRICATION. gme a no OR COL�K 101 ""A ";, - 1016 Key Notes: �D NO WORK THIS AREA, UNLESS OTHERWISE INDICATED. �D PROVIDE AND INSTALL NEW THRESHOLD. 5 on F.11 Fs- V-1 L 7 PL !4 _FS_V_1_ E-11 4 4 S V 4 1 M3 3 6 SC TECH CLOSET LE 0 15 FOM F1 OE11� Finish Notes: 1 . ALL AREAS TO RECEIVE CARPET AND BASE AS SCHEDULED U.N.O. 2. ALL AREAS TO RECEIVE RB -1 U.N.O. 3. ALL WALLS & PARTITIONS TO RECEIVE P-1 U.N.O. 4. PREP ALL EXISTING FLOOR SURFACES TO RECEIVE NEW FINISHES AS SCHEDULED. 5. PROVIDE PAINT APPLICATION APPROPRIATE TO THE SUBSTRATE TO WHICH IT IS TO BE APPLIED. 6. ALL EXPOSED GYP. BD. SURFACES, BOTH EXISTING AND NEW, ARE TO RECEIVE NEW PAINT FINISH. PREP ALL SURFACES AS REQUIRED FOR NEW PAINT FINISH. PROVIDE ONE PRIME COAT PLUS TWO FINISH COAT 7. CHANGES IN FLOOR MATERIALS THAT OCCUR AT FRAMED DOOR OPENINGS SHALL OCCUR AT THE CENTERLINE OF THE DOOR IN THE CLOSED POSITION. 8. ANY DECORATIONS USED SHALL BE NON—COMBUSTIBLE OR FLAME — RETARDANT TREATED IN AN APPROVED OF MANNER (CURTAINS, DRAPES, SHADES, HANGINGS, ETC.) 1010 10 9. ALL INTERIOR PARTITIONS, CEILING FINISHES AND TRIM OF PUBLIC AREAS TO COMPLY WITH CLASS 1 MATERIAL CLASSIFICATION; FLAME SPREAD RATING 0 TO 25, SMOKE DEVELOPED 200. ALL INTERIOR WALL AND CEILING FINISHES AND TRIM OF NON—PUBLIC AREAS TO COMPLY WITH CLASS 2 MATERIAL CLASSIFICATION; FLAME SPREAD RATING 26 TO 75, SMOKE DEVELOPED 450. 10. FLOOR COVERINGS OF PUBLIC AREAS TO MEET CLASS A INTERIOR FLOOR FINISH REQUIREMENTS; CRITICAL RADIANT FLUX OF 0.45 WATTS PER SQUARE CENTIMETER OR HIGHER, FLOOR COVERINGS OF NON—PUBLIC AREAS TO MEET CLASS B INTERIOR FLOOR FINISH REQUIREMENTS; CRITICAL RADIANT FLUX BETWEEN 0.22 WATTS PER SQUARE CENTIMETER AND 0.44 WATTS PER SQUARE CENTIMETER. 11. CARPET INSTALLATION TO MEET THE GUIDELINES OF THE CARPET AND RUG INSTITUTE—CRI CARPET INSTALLATION STANDARD—CURRENT EDITI%P( 12. PROVIDE FINISHED SCRIBE STRIPS AND FINISHED MILLWORK EDGES T) CREATE A FINISHED REVEAL CONDITION WHERE MILLWORK COUNTERS, CABINETS, ETC. "ABUT" ADJACENT PARTITION CONSTRUCTION. ALL FYPnqPn PPVPAI qHPPAr.Vq AM PnnPq Tn WAVP qAUP P1 AqTlr MU SEATTLE, 'EM MEMOPOLITAN REMW CREDIT U1410N' Southcenter Square 17250 Southcenter Blvd. Tukwila, WA 98188 DESIGN JPC DRAWN TP I MS CHECKED TP NO. 16-0699 12.22.16 PERMIT RECEIVED CITY OF TUKWILA DEC 2 2 2016 PERMIT CENTER I )E COMPLIANCE APPROVED JAN 17 2017 r Finish Plan LAMINATE FINISH AS THE CASEWORK ITEM THEY "ABUT". [ ity of Tukwila 6A iv # Ap- 00% a ^ BU LDING DIVIS1011 L�1177 @ 2013, JPC Arch1tects, PLLC CN (1) LU z (D Z C: j. (=) C:) 00 0- (D 4-J c1q (1) > 6 ON (1) C13 MU SEATTLE, 'EM MEMOPOLITAN REMW CREDIT U1410N' Southcenter Square 17250 Southcenter Blvd. Tukwila, WA 98188 DESIGN JPC DRAWN TP I MS CHECKED TP NO. 16-0699 12.22.16 PERMIT RECEIVED CITY OF TUKWILA DEC 2 2 2016 PERMIT CENTER I )E COMPLIANCE APPROVED JAN 17 2017 r Finish Plan LAMINATE FINISH AS THE CASEWORK ITEM THEY "ABUT". [ ity of Tukwila 6A iv # Ap- 00% a ^ BU LDING DIVIS1011 L�1177 @ 2013, JPC Arch1tects, PLLC I 0 m 6 c, p M E 0 L: I a SCOPE OF WORK 400 7TAF7 L A - L I^ 'W# IF SEE SHEET 1-4.0 FOR FINISH LEGEND *#*% ft� � � � � � � � � � � � � � � � � � � � � mommo 0000, (Ij A First Floor Finish Plan 1111,W Scale: 1/4"=l'—O" Finish Notes: 1. ALL AREAS TO RECEIVE CARPET AND BASE AS SCHEDULED U.N.O. 2. ALL AREAS TO RECEIVE RB -1 U.N.O. 3. ALL WALLS & PARTITIONS TO RECEIVE P-1 U.N.O. 4. PREP ALL EXISTING FLOOR SURFACES TO RECEIVE NEW FINISHES AS SCHEDULED. 5. PROVIDE PAINT APPLICATION APPROPRIATE TO THE SUBSTRATE TO WHICH IT IS TO BE APPLIED. 6. ALL EXPOSED GYP. BD. SURFACES, BOTH EXISTING AND NEW, ARE TO RECEIVE NEW PAINT FINISH. PREP ALL SURFACES AS REQUIRED FOR NEW PAINT FINISH. PROVIDE ONE PRIME COAT PLUS TWO FINISH COA 9. ALL INTERIOR PARTITIONS, CEILING FINISHES AND TRIM OF PUBLIC AREAS TO COMPLY WITH CLASS 1 MATERIAL CLASSIFICATION; FLAME SPREAD RATING 0 TO 25, SMOKE DEVELOPED 200. ALL INTERIOR WALL AND CEILING FINISHES AND TRIM OF NON—PUBLIC AREAS TO COMPLY WITH CLASS 2 MATERIAL CLASSIFICATION; FLAME SPREAD RATING 26 TO 75, SMOKE DEVELOPED 450. 10. FLOOR COVERINGS OF PUBLIC AREAS TO MEET CLASS -A INTERIOR FLOOR FINISH REQUIREMENTS; CRITICAL RADIANT FLUX OF 0.45 WATTS PER SQUARE CENTIMETER OR HIGHER, FLOOR COVERINGS OF NON—PUBLIC AREAS TO MEET CLASS B INTERIOR FLOOR FINISH REQUIREMENTS; CRITICAL RADIANT FLUX BETWEEN 0.22 WATTS PER SQUARE CENTIMETER AND 0.44 WATTS PER SQUARE CENTIMETER. 11. CARPET INSTALLATION TO MEET THE GUIDELINES OF THE CARPET 7. CHANGES IN FLOOR MATERIALS THAT OCCUR AT FRAMED DOOR RUG INSTITUTE—CRI CARPET INSTALLATION STANDARD—CURRENT OPENINGS SHALL OCCUR AT THE CENTERLINE OF THE DOOR IN THE CLOSED POSITION. 12. PROVIDE FINISHED SCRIBE STRIPS AND FINISHED MILLWORK ED CREATE A FINISHED REVEAL CONDITION WHERE MILLWORK COU 8. ANY DECORATIONS USED SHALL BE NON—COMBUSTIBLE OR FLAME — CABINETS, ETC. "ABUT" ADJACENT PARTITION CONSTRUCTION. AL RETARDANT TREATED IN AN APPROVED OF MANNER (CURTAINS, DRAPES, EXPOSED REVEAL SURFACES AND EDGES TO HAVE SAME PLASTI SHADES, HANGINGS, ETC.) LAMINATE FINISH AS THE CASEWORK ITEM THEY "ABUT". r) V) U LU C> :3 V) LU Z,t C) C) 00 0- d > 0.4 b 011 _�T — a) Cm S EAT TLE . Vmmu METROPOLITAN 1111171W C R It, � D 1: T U, N 1. 0 N Southcenter Square 17250 Southcenter Blvd. Tukwila, WA 98188 DESIGN JPC DRAWN TP I MS CHECKED TP NO. 16-0699 12.22.16 PERMIT RECEIVED CITY OF TUKWILA DEC 2 2 2016 PERMIT CENTER Mezzanine Finish Plan IEWED FOR :PROVED JAN 17 2017 Cityl of Tukwila BUILDING DIVISION 1-6,2 @ 2013, JPC Architects, PLLC 18 mils STUDS (25 GA) STUD SIZE STUD SPACING LIMITING WALL HEIGHT NON—COMPOSITE COMPOSITE 162S125 12" 7'-8" 8'-101' (1 —5/8") 169' 61-11" 8p-4" 2411 6'-1$1 71-1111 250S125 (2-1/2") 12" 10'-61p 1 V-1 1 " 161) 91-711 11 9-3'j 2411 2411 81-311 101-711 362S125 3--5/811 12" 149-01p 151-4" 16?1 129-21? 141-411 24" 14'—Olp 131-511 40OS125 41p) �r 12" 191-091 16'-511 16's 17'-6 1! 15'-411 2411 15'-71p 141-213 60OS125 (15") 1 12" 251-15" 221-1 1610 91 23-2 1 gp—glj 2411 20'-311 161-911 30 mils STUDS (20 GA — DRYWALL) STUD SIZE STUD SPACING LIMITING WALL HEIGHT NON—COMPOSITE COMPOSITE 162S125 (1 —5/8") 12" gp-311 91-1111 160) 80-511 91-211 24" 7'-411 81-311 250S125 (2-1/2") 12" 12'-911 13'-21) 1611 111-711 12'-1 pi 2411 101-2'9 101-991 362S125 3-5/8" 12" 179—011 171-1" 1610 0 15 —6" 15'-811 241) 13'-61) 14'—Olp 40OS125 (4p) 12" 181-51p 191-091 16" 16P-8" 17'-6 1! 24pp 14y -71p 15'-71p 60OS125 (61p) 12" 25'-201 251-15" 16" 22'-11 91 23-2 2411 1 20'-311 33 mils STUDS (20 GA) STUD SIZE STUD SPACING LIMITING WALL HEIGHT NON—COMPOSITE COMPOSITE–note 3 162S125 (1 —5/8") 12" 91-13" 101-411 1601 81-813 91-8$0 241) 71-7" 8)-911 250S125 (2-1/2") 12" 13'-21? 13'-11 1612 121-01) 12'-10" F241' 101-15" 111-711 362S125 3-5/811 12" 171-719 17'— 10" 16" 161-01f 169-5pp 2411 141-01f 149-910 40OS125 12" 199-011 19,-11" (401) 1611 17'—S? 181-41p 24" 151-1 It 1 60-51p 60OS125 (611) 12" 26'-20) 261-910 1611 231-9p' 241-611 1 24" 20P -6p) 211-71p Non -Bearing Non -Structural Limiting Wall Height Tables NON—BEARING WALL HEIGHT TABLE NOTES 1. WALL HEIGHTS ARE BASED ON ALLOWABLE DEFLECTION OF L/240. 2. WALLS ARE TO RECEIVE MINIMUM 1/2- GWB BOTH SIDES. 3. IF WALL HEIGHT FOR COMPOSITE ACTION IS USED, GWB IS TO BE FASTENED WITH MINIMUM #6 SCREW AT 12" O.C. 4. HEIGHTS ARE BASED ON THE SSMA CATALOG. 5. TABLES ARE BASED ON 5 PSF LATERAL LOAD. 6. TABLES'TO BE USED FOR NON—BEARING NON—STRUCTURAL STUD WALLS ONLY. 7. MATERIAL GAUGES ARE FOR REFERENCE ONLY. 8. WHERE GWB DOES NOT EXTEND TO TOP OF STUDS USE LIMITING WALL HEIGHTS FOR NON COMPOSITE WALLS AND PROVIDE MECHANICAL BRACING OF STUD FLANGES PER SSMA STANDARDS. DESI DER Omil WAL EXIS AND EXISTING STRUCTURE FILL VOID WITH ACOUSTICAL SEALANT BOTH SIDES (OUTER) DEFLECTION TRACK (INNER) HEAD TRACK SECURE STUDS TO LEG OF HEAD TRACK INSULATION AS NOTED BELOW INSULATION TO EXTEND 2'-0" BEYOND EACH SIDE OF WALL AS NOTED BELOW CEILING AS SPECIFIED, NOTE, SOME LOCATIONS OPEN TO STRUCTURE. ONE LAYER 5/8" GWB EACH SIDE OF WALL CONT. MTL. RUNNER MECHANICALLY FASTENED TO SUBFLOOR WITH 0.157" DIA. HILTI XU EVERY 24" O.C. (25 GA. TRACK 48" O.C. WITH 20 GA.), WITH AN EMBED. DEPTH OF 3/4" SPECIFIED BASE ACOUSTICAL SEALANT BOTH SIDES FINISHED FLOOR 1/8" FOAM TAPE WALL TYPE WALL HT. STUD SIZE STUD THICKNESS STUD SPACING WALL THICKNESS INSULATION UL DE IGN NO. COMMENTS WALL I CEILING B VARIES 3 5 /,9" 30 Mils 94" n r 4 7 /8" SB SB REF. 7&8/1-9.1 FnR ARANNG Full Ht. Partition Scale: 3"=l'–O" *SB=SOUND AZIFENUATION -BATTS FR=FIRE RESISTIVE PROVIDE WALL BRACING @ ALL NON—LOAD BEARING WALLS SO THAT NO WALL HAS AN UNSUPPORTED LENGTH GREATER THAN 9'-0". EXCEPTION: WALLS THAT ARE 12'-0" OR LESS IN LENGTH & SUPPORTED @ EA. END BY AN INTERSECTING WALL OR STRUCTURE DO NOT REQUIRE WALL BRACING. INTERSECTING WALLS ARE CONSIDERED AS WALL SUPPORTS. WALLS MAY ONLY EXTEND UP TO 2'-0" BEYOND AND A SUPPORT WITHOUT BEING SUPPORTED AT ITS END FASTEN TO STRUCTURE ABOVE WITH 3/16" DIA. POWDER ACT. FASTENERS, MIN. 1000 LB. PULLOUT (@ STL. DECK FASTEN W/ (2) #10 SCREWS) ACOUSTICAL TILE CEILING METAL CASING BEAD 2-1/2" (22 GA.) TRACK W/ (2) #10 SCREWS @ 24" O.C. PAINT EXPOSED SURFACES FLAT BLACK SHIM AS REQ'D, SECURE TO GRID INSULATION TO EXTEND 2'-0" BEYOND EACH SIDE OF WALL AS NOTED BELOW CEILING AS SPECIFIED PAINT REVEAL FLAT BLACK OR TAPED BLACK INSULATION AS NOTED BELOW ONE LAYER 5/8" GWB EACH SIDE OF WALL MTL. STUDS — WIDTH, GA. & SPACING AS NOTED BELOW CONT. MTL. RUNNER MECHANICALLY FASTENED TO SUBFLOOR WITH 0.157" DIA. HILTI XU EVERY 24" O.C. (25 GA. TRACK 48" O.C. WITH 20 GA.), WITH AN EMBED. DEPTH OF 3/4" SPECIFIED BASE FINISHED FLOOR 1/8" FOAM TAPE TYPE WALL HT. STUD SIZE THICKNESS STUD SPACING THICKNESS INSULATION RRE RA TING/ I UL DESIGN NO. COMMENTS WALL I CEILING B VARIES 2 1/2" 18 Mils 24" O.C. 3 3 /4" REF. 7&8/1-9.1 FnR ARANNG Ceiling Ht. Partition Scale: 3"=1'–O" *SB=SOUND AlTENUATION BATTS FR=FlRE RESISTIVE 0 0 0 Not Used Not Used Partition Bracing Detail Partition Bracing Detail Scale: 3"=l'–O" Scale: 3"=l'–O" Scale: 3"=l'–O" Scale: 3"=l'–O" APPROVED "FIRE EXTINGUISHER" SIGNAGE — 3" HIGH WHITE HELVETICA LETTERING ON RED BACKING OF 8"X12" SIGN. PROVIDE SIGNAGE ON ALL FOUR SIDES OF COLUMN ENCLOSURE WHEN FIRE EXTINGUISHER OCCURS AT COLUM� BUILDING STANDARD FIRE EXTINGUISHER CABINET WHEN LOCATED AT COLUMNS, CABINET AND SIGNAGE TO BE CENTERED ON COLUMN ENCLOSUR . TYPICAL, U.N.O. -.7w x I W -ml 5 1 a whim KTA'TAI.M NOTE INSTALL LOCAL ELECTRICAL AND TELEPHONE WALL NOTE: HEIGHTS ARE AS NOTED OUTLETS AND SWITCHPLATES AT NEAREST STUD FROM SCALED UNLESS DIRECTED BY B/S TO LOCATION ON PLAN UNLESS SPECIFICALLY DIMENSIONED. BE DIFFERENT Typical Mounting Heights Scale: N.T.S. Typical Partition at Curtain Wall Scale: 3/4"=l'–O" DO NOT SECURE PARTITION TO GLAZING SYSTEM, ATTACH AT WALL ABOVE AND BELOW GLAZING BOX STUD TO CONFORM TO SITE CONDITIONS LINE OF SILL (VARIES PER SITE CONDITION) MTL. STUD ATTACHED TO VERTICAL MULLION W/ DOUBLE SIDED (STICKY) FOAM TAPE Typical Mullion/Partition Intersection Scale: 3"=l'–O" j STUD WIDTH TO MATCH WALL; 20 GA. TRACK CONNECTED TO CONC. SLAB W/ 3/16" DIA. X 5/8" LONG POWDER ACTIVATED FASTENERS (4 MIN.) STRUCTURE ABOVE STUD WIDTH TO MATCH WALL; 20 GA. BRACE @ 6'-0" O.C. MAX. 2-1/2" X 20 GA. TRACK ANCHOREDTO CHANNEL ACOUSTICAL TILE CEILING BLOCKING AS REQUIRED METAL CASING BEAD 22 GA. 2-1/2" RUNNER & CONT. FOAM PAD — ATTACH TO CEILING GRID W/ (2) #10 SCREWS @ 24" O.C. PAINT REVEAL FLAT BLACK OR USE BLACK RUNNER C14 LU z C) C:� C 00 W 0r_ > < 4-J c1q <D :3 > 6 —(D S EATTLE mbrkbrOLITAN AMR CRE . DIT tJ4410N Southcenter Square 17250 Southcenter Blvd. Tukwila, WA 98188 DESIGN JPC DRAWN TP I MS CHECKED TIP NO. 16-0699 12.22.16 PERMIT RECEIVED CITY OF TUKWILA DEC 2 20% PERMIT CENTER Construction Details (IEWED FOR COMPLIANCE PPROVED N 17 2017 C �y of Tukwila BUILI)ING DIVISION I C.) 7� m U) < x C3 C-4 CD < to E j STUD WIDTH TO MATCH WALL; 20 GA. TRACK CONNECTED TO CONC. SLAB W/ 3/16" DIA. X 5/8" LONG POWDER ACTIVATED FASTENERS (4 MIN.) STRUCTURE ABOVE STUD WIDTH TO MATCH WALL; 20 GA. BRACE @ 6'-0" O.C. MAX. 2-1/2" X 20 GA. TRACK ANCHOREDTO CHANNEL ACOUSTICAL TILE CEILING BLOCKING AS REQUIRED METAL CASING BEAD 22 GA. 2-1/2" RUNNER & CONT. FOAM PAD — ATTACH TO CEILING GRID W/ (2) #10 SCREWS @ 24" O.C. PAINT REVEAL FLAT BLACK OR USE BLACK RUNNER C14 LU z C) C:� C 00 W 0r_ > < 4-J c1q <D :3 > 6 —(D S EATTLE mbrkbrOLITAN AMR CRE . DIT tJ4410N Southcenter Square 17250 Southcenter Blvd. Tukwila, WA 98188 DESIGN JPC DRAWN TP I MS CHECKED TIP NO. 16-0699 12.22.16 PERMIT RECEIVED CITY OF TUKWILA DEC 2 20% PERMIT CENTER Construction Details (IEWED FOR COMPLIANCE PPROVED N 17 2017 C �y of Tukwila BUILI)ING DIVISION I I C) 2 PROVIDE CEILING EXPANSION JOINTS AS NECESSARY DIVIDING CEILING INTO AREAS NO GREATER THAN 2,500 S.F. Expansion Joint for Ceil_ing Exceeding 2500 SF Scale: 3*'=1'-0" m Ln X C�. C) Ln C> B -:j g U� C �2 E L: 0 Header Detail Scale: 3"=1'-0' SEE RCP HEADER SOUND BATT INSULATION BRACE TO STRUCTURE ABOVE OTS CEILING PER RCP GWB CEILING PER RCP GWB CEILING PER RCP HANGER WIRE i PERIMETER MAII AND PERIMETEF CROSS TEE CAT. D, E & F ATTACHED BERC2 BY ARMSTRONG CEILING ARMSTRONG STABILIZER 3AR OR OTHER SUITABLE 3YSTEM TO KEEP PERIMETER "OMPONENTS FROM 3PREADING APART TYPICAL WALL MOULDING 3Y ARMSTRONG CEILING FYPICAL HEAVY DUTY 3USPENDED CEILING "RID SYSTEM BY \RMSTRONG Suspended Ceiling 0) Perimeter Support Scale: 1 1/2"=V-0" EXISTING STRUCTUTRE ��EXISTING STRUCTURE PAINT R EVEAL FLA PAINT REVEAL FLAT BLACK OR TAPED kll BLACK BLACK ONE LAYER 5/8" GWB ONE LAYER 5/8" GW6 rA I I �IM� m Ln X C�. C) Ln C> B -:j g U� C �2 E L: 0 Header Detail Scale: 3"=1'-0' SEE RCP HEADER SOUND BATT INSULATION BRACE TO STRUCTURE ABOVE OTS CEILING PER RCP GWB CEILING PER RCP GWB CEILING PER RCP HANGER WIRE i PERIMETER MAII AND PERIMETEF CROSS TEE CAT. D, E & F ATTACHED BERC2 BY ARMSTRONG CEILING ARMSTRONG STABILIZER 3AR OR OTHER SUITABLE 3YSTEM TO KEEP PERIMETER "OMPONENTS FROM 3PREADING APART TYPICAL WALL MOULDING 3Y ARMSTRONG CEILING FYPICAL HEAVY DUTY 3USPENDED CEILING "RID SYSTEM BY \RMSTRONG Suspended Ceiling 0) Perimeter Support Scale: 1 1/2"=V-0" PER RCP Header Detail Scale: 3"=1'-0" SEE RCP 31UL SOUND BATT INSULATION BRACE TO STRUCTURE ABOVE OTS CEILING PER RCP GWB CEILING PER RCP NO. 9 GA. LATERAL SUPPORT WIRE WITHIN 3" OF EACH CORNER OF LIGHT FIXTURE. SPLAY WIRES AS SHOWN AND FASTEN TO BEAM OR PURLIN. MIN. OF 3 WIRE TURNS EACH. CONNECTION POINT NO. 9 GA. LATERAL SUPPORT WIRE AT - CENTER ENDS OF EA. FIXTURE. FIXTURE SUPPORT WIRE SUPPLIED BY CEILING CONTRACTOR Light Fixture Bracing Diagram Scale: N.T.S. ,,-\ 60- MAX. TYP. 45 - RECESSED FLUORESCENT FIXTURE MAIN STRUCTURAL RUNNER 4'-0" O.C. NOTES: 1. LATERAL BRACING CLUSTER: (4) 12 GA. GALV. SOFT -ANNEALED MILD STEEL WIRES SECURED TO MAIN RUNNER WITHIN 2" OF CROSS 'T' AND SPLAYED 90 DEGREES FROM EACH OTHER AT 45 DEGREES MAX. ABOVE HORIZONTAL. CLUSTERS PLACED 12'-0" O.C. MAX. AND 6'-0" MAX. FROM EACH WALL. WIRES SHOULD BE TAUT WITHOUT CAUSING CEILING TO LIFT. 2. SUSPENSION WIRE: 12 GA. GALV. SOFT -ANNEALED MILD STEEL WIRE ENCASED IN J" DIAM. CONDUIT (FOR UPLIFT RESTRAINT); SECURE WIRE TO MAIN RUNNER WITHIN 2" OF CROSS 'T. CONDUIT TO OCCUR AT EVERY LATERAL BRACING CLUSTER AND SUSPENSION WIRES TO OCCUR AT 4'-0" O.C. MAX. EACH WAY. 3 TURNS MIN. WITHIN 3" TYP. NOTE #1 FASTEN RUNNERS TO PERIMETER WALL ANGLE AT (2) ADJACENT SIDES. PROVIDE MIN. 2" WIDE WALL ANGLE MAIN RUNNER, HEAVY DUTY CROSS 'T" VIEW SHOWING LATERAL BRACING CLUSTER AND SUSPENSION WIRE Ceiling Bracing Diagram Scale: N.T.S. NOTE #2 NOTE #1 45' MAX. TYP. RUNNER ENDS AT OPPOSITE WALLS 2" MAX. TYP. TO FLOAT FREE ON PERIMETER ANGLE. PROVIDE 3/4" CLEARANCE 45- MAX. TYP. M AIX. TYP. BETWEEN ENDS OF GRID & WALL REVIEWED FO CODE COMPLIAt APPROVED 2017 JAN 17 City Of TiulkWik BUILDING DIVIS miot 1-0 C) LU Z ZI. C> c) C 00 < > C�, C=) (V 0- S EAT T L E METKOPOLITAK TO N Zlffl Ckt,DIT UN Southcenter Square 17250 Southcenter Blvd. Tukwila, WA 98188 DESIGN JPC DMWN TP I MS CHECKED TP NO. 16-0699 12.22.16 PERMIT RECEIVED CITY OF TUKWILA D c 2 2 2016 E PERMIT CENTER Ceiling Details ��EXISTING STRUCTURE PAINT REVEAL FLAT BLACK OR TAPED BLACK ONE LAYER 5/8" GW6 PER RCP Header Detail Scale: 3"=1'-0" SEE RCP 31UL SOUND BATT INSULATION BRACE TO STRUCTURE ABOVE OTS CEILING PER RCP GWB CEILING PER RCP NO. 9 GA. LATERAL SUPPORT WIRE WITHIN 3" OF EACH CORNER OF LIGHT FIXTURE. SPLAY WIRES AS SHOWN AND FASTEN TO BEAM OR PURLIN. MIN. OF 3 WIRE TURNS EACH. CONNECTION POINT NO. 9 GA. LATERAL SUPPORT WIRE AT - CENTER ENDS OF EA. FIXTURE. FIXTURE SUPPORT WIRE SUPPLIED BY CEILING CONTRACTOR Light Fixture Bracing Diagram Scale: N.T.S. ,,-\ 60- MAX. TYP. 45 - RECESSED FLUORESCENT FIXTURE MAIN STRUCTURAL RUNNER 4'-0" O.C. NOTES: 1. LATERAL BRACING CLUSTER: (4) 12 GA. GALV. SOFT -ANNEALED MILD STEEL WIRES SECURED TO MAIN RUNNER WITHIN 2" OF CROSS 'T' AND SPLAYED 90 DEGREES FROM EACH OTHER AT 45 DEGREES MAX. ABOVE HORIZONTAL. CLUSTERS PLACED 12'-0" O.C. MAX. AND 6'-0" MAX. FROM EACH WALL. WIRES SHOULD BE TAUT WITHOUT CAUSING CEILING TO LIFT. 2. SUSPENSION WIRE: 12 GA. GALV. SOFT -ANNEALED MILD STEEL WIRE ENCASED IN J" DIAM. CONDUIT (FOR UPLIFT RESTRAINT); SECURE WIRE TO MAIN RUNNER WITHIN 2" OF CROSS 'T. CONDUIT TO OCCUR AT EVERY LATERAL BRACING CLUSTER AND SUSPENSION WIRES TO OCCUR AT 4'-0" O.C. MAX. EACH WAY. 3 TURNS MIN. WITHIN 3" TYP. NOTE #1 FASTEN RUNNERS TO PERIMETER WALL ANGLE AT (2) ADJACENT SIDES. PROVIDE MIN. 2" WIDE WALL ANGLE MAIN RUNNER, HEAVY DUTY CROSS 'T" VIEW SHOWING LATERAL BRACING CLUSTER AND SUSPENSION WIRE Ceiling Bracing Diagram Scale: N.T.S. NOTE #2 NOTE #1 45' MAX. TYP. RUNNER ENDS AT OPPOSITE WALLS 2" MAX. TYP. TO FLOAT FREE ON PERIMETER ANGLE. PROVIDE 3/4" CLEARANCE 45- MAX. TYP. M AIX. TYP. BETWEEN ENDS OF GRID & WALL REVIEWED FO CODE COMPLIAt APPROVED 2017 JAN 17 City Of TiulkWik BUILDING DIVIS miot 1-0 C) LU Z ZI. C> c) C 00 < > C�, C=) (V 0- S EAT T L E METKOPOLITAK TO N Zlffl Ckt,DIT UN Southcenter Square 17250 Southcenter Blvd. Tukwila, WA 98188 DESIGN JPC DMWN TP I MS CHECKED TP NO. 16-0699 12.22.16 PERMIT RECEIVED CITY OF TUKWILA D c 2 2 2016 E PERMIT CENTER Ceiling Details I C) z Built-in Upholstered Bench Scale: 1"=l'—O" :)HOLSTERED 6" DLSTER SECURE TO :-NCH WITH VELCRO i" UPHOLSTERED HIGH )ENSITY FOAM CUSHION ff MILLWORKER SECURE '0 PLATFORM WITH IELCRO DOUBLE LAYER OF 3/4" PLYWOOD SUBSTRATE PLAM AT ALL EXPOSED EXTERIOR SURFACES TYPICAL PLAM BASE AT TOE KICK MI AkA MAkIrl 'r^ nr- kJ^IIKI'rr-r% Coat Hooks Scale: 3"=l'—O" Mir*c %Jr% 1 1 I%J%JFXJ. IVI%J%JINL- I I I U1 L I J" DIAMETER, J" PROJECTION, NOTCHED CYLINDRICAL KNOB, SATIN NICKEL FINISH " t t7) co C�' M Ln REVIEWED FOR 'n CODE COMPLIANC c: - APPROVED '2 JAN 17 2017 CN LU z 4-J CN (D > (D 0- — 6 W ON 100 '"w"TLE SEA I Mm'. MIETKOPOLITAN C RLE1 D I T U N f-0 N, Southcenter Square 17250 Southcenter Blvd. Tukwila, WA 98188 DESIGN JPC DRAWN TP I MS CHECKED TP NO. 16-0699 12.22.16 PERMIT RECEIVED CITY OF TUKWILA DEC 2 2 2016 PERMIT CENTER Casework Details 1-93 @ 2013, JPC Architects, PLLC I 0 M V) X IL CD �5 0 ::E E 0 6 LL U LL. LLj QF LL_ LL a = C,4 C I < C Door Type A Scale: 3/8"=1'-0" Not Used Scale: 3/8"=l'—O' r1r%1 lIrllrlr% 31`11M M3 M DOOR PER SCHEDULE 3'-0" X 8'-0" X 1-3/4" SC, FLUSH PANEL PAINT GRADE WOOD DOOR WITH ALUMINUM FRAME. DOOR AND FRAME PAINTED TO MATCH ADJACENT WALL 1/4" TEMPERED SAFETY GLASS PER SBC SEC. 2406. WITH WF -2 BASE, AS SPECIFIED Door Jamb (Head Similar) Scale: 6"=1'-0" 1-9/16" 6"X . 04 ALUMINUM FRAME DOUBLE STUDS AT EACH SIDE OF JAMBS SPECIFIED PARTITION Door Type B Scale: 3/8"=l'—O' Not Used Scale: 3/8"=l'—O' 32" MIN. CLR. OPE I Sound Stop Pocket Door Scale: 6"=1'-0" 3'-0" X 8'-0" X 1-3/4" SC, FLUSH PANEL PAINT GRADE WOOD DOOR WITH ALUMINUM FRAME. DOOR AND FRAME PAINTED TO MATCH ADJACENT WALL BASE, AS SPECIFIED 'T PH @ 16" C/C / J" X I" FOAM PAD SNAP ON MFS -0007 W J" PILE AND FOAM PAD J" X J" Sliding Door 0) Demountable S stem Scale: 6"=l'—O" -1 .- ADA COMPLIANT DOOR PULL MOUNTED AT 33" A.F.F. TO BOTTOM OF PULL PAINT INTERIOR OF POCKET FLAT BLACK PARTITION AS SPECIFIED PROVIDE STOP INSIDE POCKET OF DOOR ON BOTH SIDES AT FLOOR TO ALLOW 1-1/2" BETWEEN DOOR PULL AND DOOR FRAME. ALUMINUM FRAME SOUND STOP MFS -0062 W/ J" PILE TRIM MOLDING MFS -0023 24' Standard Head Scale: 3"=l'—O" 1Y16" TA' 3/8" e N Lam R - #10 x 2,Y2" PH Rob. ST @ 8" c/c Header MFS -0051 -1 Snap -on MFS -0054-1 w/ Gasket MFG -0007 stem Sill MFS -0073-1 Snap -on MFS -0075-1 w/ Gasket MFG -0007 &. Y8" Pile Y4" x Y4" x 2" Self Adh. Guide #12 x 2,1/4" FH Rob. Mas. (For MFS -0075-1 - 2x) #12 x 2Y4" HWH Slot Mas. @ 16" c/c Hardware Sets: HS- 1 MODIFY TO RECIEVE CARD READER AND SECURITY HEIGHT STRIP CAMERA 1005 EXT. HARDWARE SET #1 EXISTING ENTRY DOOR 1000 + 1005 *1 EXIT DEVICE ED5200S P12 M54 M92 M94 630 CR 1006 EXT. *2 CYLINDERS 1080-114 CT6 (DEVICE & SWITCH) 626 CR 1007 EXT. *1 POWER TRANSFER PT -2U SD 1008 ANODIZED *1 AUTOMATIC OPERATOR 8100 PUSH X FWH 628 RE U A IUM FRAME *2 SWITCHES 6X6-3 630 WI *1 KEY SWITCH MKA 630 CR RED SAFETY GLASE 3C SEC. 2406. *1 POWER SUPPLY 782 CR EXT. REPLACE THE EXISTING PUSH BAR UNIT WITH THE ELECTRIFIED EXIT DEVICE, REPLACE THE EXISTING DOOR 1014 B AL HS -3 CLOSER WITH THE SPECIFIED AUTOMATIC OPERATOR. OPERATION - AFTER HOURS, THE DOOR IS SECURED 1015 A AL BY THE EXIT DEVICE. EGRESS IS ALLOWED AND MONITORED BY THE SPECIFIED REQUEST TO EXIT SWITCH. 1016 C LATCH IS RETRACTED ELECTRICALLY BY CARD READER FROM THE EXTERIOR (BY OTHERS) OR INSIDE HS -4 - DEMOUNTABLE SYSTEM BY MURAFLEX -ESS GLASS OPERATOR SWITCH ACTIVATION. EXTERIOR CARD READER ACTIVATION ALSO ACTIVATES THE EXTERIOR C) c1q - DOOR OPERATOR SWITCH. BUSINESS HOURS, DEVICE IS ELECTRICALLY HELD IN THE RETRACTED POSITION TO C a) HS -4 ,DDER PULL, ALLOW UNRESTRICTED ACCESS IN BOTH DIRECTIONS, KEY SWITCH ACTIVATES/DEACTIVATES THE LATCH U B AL 1`0 BACK RETRACTION. COORDINATE AND CONFIRM FINAL OPERATION WITH THE OWNER, SECURITY ACCESS AND THE tn EXT. -ATION ELECTRICAL ENGINEER (REF 08 71 00 1.5-A-6). REUSE ALL OTHER EXISTING HARDWARE. UJI z C) HARDWARE SET #2 DOOR 1015 + 1021 (D C) 00 3 HINGES TA2714 4XX41h 652 MC a) AS SPECIFIED *1 ELECTRIC HINGE TA2714 4%X41h QC8 652 MC *1 ELECTRIC LOCK ML20906 SEC NSA CT6 626 CR 1 CLOSER 7500RA 689 NO 1 KICK PLATE K0050 10"X2' LDW 84E 630 TR C14 (D :3 1WALL STOP 1270 WV 630 TR > (D *2 ELECTROLYNX8 CABLES QC -C1500 MC MMW) 01- *1 POWER SUPPLY BPS -24-1 CR 6 01- (5 100 PERIMETER GASKETS BY ALUMINUM FRAME MANUFACTURER. DOOR MANUFACTURER TO INSTALL PERIMETER WIRE CHASE FOR ELECTRIFIED LOCK. CARD READER BY OTHERS. HARDWARE SET #03 DOOR 1014 QTY 1-1/2 PAIR - BUTT HINGES SEATTLE QTY 1 - LEVER LATCHSET METROPOLITAN QTY 1 - BLDG STD. DOOR STOP QTY 1 SET - SILENCERS Ckt..'DIT UTNIO,t4 Southcenter Square PERIMETER GASKETS BY ALUMINUM FRAME MANUFACTURER. 17250 Southcenter Blvd. Tukwila, WA 98188 HARDWARE SET #04 DOORS 1008, 1016, 1018 + 1019 ALL HARDWARE BY SYSTEM MANUFACTURER #10 x 2,Y2" PH Rob. ST @ 8" c/c Header MFS -0051 -1 Snap -on MFS -0054-1 w/ Gasket MFG -0007 stem Sill MFS -0073-1 Snap -on MFS -0075-1 w/ Gasket MFG -0007 &. Y8" Pile Y4" x Y4" x 2" Self Adh. Guide #12 x 2,1/4" FH Rob. Mas. (For MFS -0075-1 - 2x) #12 x 2Y4" HWH Slot Mas. @ 16" c/c Door Sill 0 Demountable System Scale: 6"=l'—O" 1 1/2 -- JAMB MFS -0073-1 SNAP-ON MFS -0074-1 W/ GASKET MFG -0007 #10 X 2-1/2" SDST PH @ 16" C/C Typical Jamb 0) Demountable System Scale: 6"=1'-0" I Door Schedule I NO. I TYPE I FRAME I HDWE I RATING V#Wwky 1000 < HS- 1 MODIFY TO RECIEVE CARD READER AND SECURITY HEIGHT STRIP CAMERA 1005 EXT. HS- 1 MODIFY TO RECIEVE CARD READER AND SECURITY HEIGHT STRIP CAMERA. EXISTING DOOR HARDWARE IS EMERGENCY PUSH BAR. EXISTING DOOR IS UNLOCKED FROM INTERIOR. PAINT DOOR P -X. 1006 EXT. 1007 EXT. 1008 C HS -4 A Door Sill 0 Demountable System Scale: 6"=l'—O" 1 1/2 -- JAMB MFS -0073-1 SNAP-ON MFS -0074-1 W/ GASKET MFG -0007 #10 X 2-1/2" SDST PH @ 16" C/C Typical Jamb 0) Demountable System Scale: 6"=1'-0" I Door Schedule I NO. I TYPE I FRAME I HDWE I RATING V#Wwky 1000 EXT. HS- 1 MODIFY TO RECIEVE CARD READER AND SECURITY HEIGHT STRIP CAMERA 1005 EXT. HS- 1 MODIFY TO RECIEVE CARD READER AND SECURITY HEIGHT STRIP CAMERA. EXISTING DOOR HARDWARE IS EMERGENCY PUSH BAR. EXISTING DOOR IS UNLOCKED FROM INTERIOR. PAINT DOOR P -X. 1006 EXT. 1007 EXT. 1008 C HS -4 DEMOUNTABLE SYSTEM BY MURAFLEX 1010 EXT. 1011 EXT. 1014 B AL HS -3 1015 A AL HS -2 1016 C HS -4 - DEMOUNTABLE SYSTEM BY MURAFLEX 1018 C HS -4 - DEMOUNTABLE SYSTEM BY MURAFLEX 1019 C HS -4 - DEMOUNTABLE SYSTEM BY MURAFLEX 1021 B AL HS -2 - 2002 EXT. TRIM CORNER MOLDING RE IEWED FOR CODE COMPLIAW APPROVED JAN 17 2017 DESIGN JPC DRAWN TP I MS CHECKED TP NO. 16-0699 12.22.16 PERMIT RECEIVED CITY OF TUKWILA DEC 2 2 2016 PERMIT CENTER Door Schedule Elevations + Details I_ 10 , A I @ 2013, JPC Architects, PLLC