HomeMy WebLinkAboutPermit D16-0355 - HYDRO FOR LESS - NEW CEILING GRIDS AND DOORSHYDRO FOR LESS 9100 E MARGINAL WAY S EXPIRED 08/02/17 D16-0355 Parcel No: Address: City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-438-9350 Web site: http://www.TukwilaWA.gov DEVELOPMENT PERMIT 5422600150 9100 E MARGINAL WAY S Project Name: HYDRO FOR LESS Permit Number: D16-0355 Issue Date: 1/31/2017 Permit Expires On: 7/30/2017 Owner: Name: Address: Contact Person: Name: ' Address: Contractor: Name: Address: License No: Lender: Name: Address: WOOD MEADOWS LLC 901 POWELL AVE SW #101 C/O JSH PROPERTIES INC, RENTON, WA, 98057 YURIY MOMOTYUK 27327 48 AVE S , KENT, WA, 98032 YUMO CONSTRUCTION LLC 27327 48 AVE S , KENT, WA, 98032 YUMOCCL9520T WOOD MEADOWS LLC 901 POWELL AVE SW #101 C/O JSH PROPERTIES INC, RENTON, WA, 98057 Phone: (253) 332-2177 Phone: (253) 332-2177 Expiration Date: 2/28/2018 DESCRIPTION OF WORK: INSTALL NEW CEILING GRIDS, NEW DOORS INTERIOR Project Valuation: $11,200.00 Type of Fire Protection: Sprinklers: Fire Alarm: Type of Construction: VB Electrical Service Provided by: TUKWILA Fees Collected: $883.36 Occupancy per IBC: B Water District: TUKWILA Sewer District: TUKWILA Current Codes adopted by the City of Tukwila: International Building Code Edition: International Residential Code Edition: International Mechanical Code Edition: Uniform Plumbing Code Edition: International Fuel Gas Code: 2015 2015 2015 2015 2015 National Electrical Code: WA Cities Electrical Code: WAC 296-46B: WA State Energy Code: 2014 2014 2014 2015 Public Works Activities: Channelization/Striping: Curb Cut/Access/Sidewalk: Fire Loop Hydrant: Flood Control Zone: Hauling/Oversize Load: Land Altering: Volumes: Cut: 0 Fill: 0 Landscape Irrigation: Sanitary Side Sewer: Number: 0 Sewer Main Extension: Storm Drainage: Street Use: Water Main Extension: Water Meter: No / % Permit Center Authorized Signature: t A) L RJ Date: '` / I hearby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this development permit and agree to the conditions''tached to this permit. Signature: Print Name: U / u �- -y ,€7 2 c7 ?S/c-e �C Date: 01—.37—/ This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: ***BUILDING PERMIT CONDITIONS*** 2: Work shall be installed in accordance with the approved construction documents, and any changes made during construction that are not in accordance with the approved construction documents shall be resubmitted for approval. 3: All permits, inspection record card and approved construction documents shall be kept at the site of work and shall be open to inspection by the Building Inspector until final inspection approval is granted. 4: New suspended ceiling grid and light fixture installations shall meet the seismic design requirements for nonstructural components. ASCE 7, Chapter 13, 5: All construction shall be done in conformance with the Washington State Building Code and the Washington State Energy Code. 6: There shall be no occupancy of a building until final inspection has been completed and approved by Tukwila building inspector. No exception. 7: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center. 8: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 9: Egress doors shall be readily openable from the egress side without the use of a key or special knowledge or effort. (IFC 1008.1.8.3 subsection 2.2) 10: Dead bolts are not allowed on auxiliary exit doors unless the dead bolt is automatically retracted when the door handle is engaged from inside the tenant space. (IFC Chapter 10) 11: Exit hardware and marking shall meet the requirements of the International Fire Code. (IFC Chapter 10) 12: Door handles, pulls, latches, locks and other operating devices on doors required to be accessible by Chapter 11 of the International Building Code shall not require tight grasping, tight pinching or twisting of the wrist to operate. (IFC 1008.1.9.1) 14: A fire alarm system is required for this project. The fire alarm system shall meet the requirements of N.F.P.A. 72 and City Ordinance #2437. 17: Maintain automatic fire detector coverage per N.F.P.A. 72. Addition/relocation of walls, closets or partitions may require relocating and/or adding automatic fire detectors. 15: Maintain square foot coverage of detectors per manufacturer's specifications in all areas including: closets, elevator shafts, top of stairwells, etc. (NFPA 72-17.5.3.1) 18: Maintain fire alarm system audible/visual notification. Addition/relocation of walls or partitions may require relocation and/or addition of audible/visual notification devices. (City Ordinance #2437) 16: All new fire alarm systems or modifications to existing systems shall have the written approval of The Tukwila Fire Prevention Bureau. No work shall commence until a fire department permit has been obtained. (City Ordinance #2437) (IFC 901.2) 19: An electrical permit from the City of Tukwila Building Department Permit Center (206-431-3670) is required for this project. 13: Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (City Ordinances #2436 and #2437) 20: Any overlooked hazardous condition and/or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. 21: These plans were reviewed by Inspector 511. If you have any questions, please call Tukwila Fire Prevention Bureau at (206)575-4407. PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 1700 BUILDING FINAL** 1400 FIRE FINAL 0409 FRAMING 0606 GLAZING 0603 ROOF/CEILING INSUL 0406 SUSPENDED CEILING CITY OF TUKI, A Community Development Department Public Works Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.TukwilaWA.gov Building Permit No. AN �Q 0153— Project 3— Project No. (� Date Application Accepted: id --)191 Date Application Expires: te (For office use only) CONSTRUCTION PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **Please Print** SITE LOCATION Site Address: 9/ 6C' mer Tenant Name:�Yd 4p'La�SS King Co Assessor's Tax No.: 5.-92- ZG ° -C-C) Suite Number: PROPERTY OWNER Name:`/f Name: >> e� t/JX Afe4,6cr,.e.�s ,,,,,c__ Address: '' 5 City: 744," iecs f`76, State: bf,4 Zip: yaric CONTACT PERSON - person receiving all project communication Name:`/f cc v, y ®v -,v 6�-. �u Address: Z "13 Z yr Atop'-- City: ' State: C.A- Zip: gf.?,-03. Phone: - State: Email: State: Zip: GENERAL CONTRACTOR INFORMATION Company Name: .✓ )(.e%/'M ( / Uig Gc.r GV`i' e71 Address: 432 i, y fm / $ City: i , State: LJ fr Zip: 9to yz Phone: "<-3,_ 5 3 z, 2/7.4.Fax: Contr Reg No.: Exp Date: Address: Tukwila Business License No.: State: H:\Applications\Forms-Applications On Line \2012 Applications\Permit Application Revised - 2-7-12.docx Revised: February 2012 bh Floor: New Tenant: ❑ Yes R. No ARCHITECT OF RECORD Name: t' n W�oc cp Company Name: f c Ci- ry W Address: Architect Name: Address: State: City: State: Zip: Phone: Fax: Email: ENGINEER OF RECORD Name: t' n W�oc cp Company Name: f c Ci- ry W Address: Engineer Name: Address: State: City: State: Zip: Phone: Fax: Email: LENDER/BOND ISSUED (required for projects $5,000 or greater per RCW 19.27.095) Name: t' n W�oc cp /li _ fl�o d f c Ci- ry W Address: City: State: Zip: Page 1 of 4 BUILDING PERMIT INFORMATI( • 206-431-3670 Valuation of Project (contractor's bid price): $ / /�'2 0 Existing Building Valuation: $ �� r (900 Describe the scope of work (please provide detailed information): . °,-/ > ' LV f'LE x c / j 74--, vi Will there be new rack storage? ❑ .... Yes K..No If yes, a separate permit and plan submittal will be required. Provide All Building Areas in Square Footage Below PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact: Handicap: Will there be a change in use? ❑ Yes 0 No If "yes", explain: FIRE PROTECTION/HAZARDOUS MATERIALS: ❑ Sprinklers 0 Automatic Fire Alarm 0 None 0 Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? 9 Yes 0 No If `yes', attach list of materials and storage locations on a separate 8-1/2" x 11 " paper including quantities and Material Safety Data Sheets. SEPTIC SYSTEM 0 On-site Septic System — For on-site septic system, provide 2 copies of a current septic design approved by King County Health Department. H:Wpplications'Forms-Applications On Line \2012 Applications'Permit Application Revised - 2-7-12.docx Revised: February 2012 bh Page 2 of 4 Existing Interior Remodel Addition to Existing Structure New Type of Construction per IBC Type of Occupancy per IBC 1St Floor 1>z '° 2nd Floor 3rd Floor Floors thru Basement Accessory Structure* Attached Garage Detached Garage Attached Carport Detached Carport Covered Deck Uncovered Deck PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact: Handicap: Will there be a change in use? ❑ Yes 0 No If "yes", explain: FIRE PROTECTION/HAZARDOUS MATERIALS: ❑ Sprinklers 0 Automatic Fire Alarm 0 None 0 Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? 9 Yes 0 No If `yes', attach list of materials and storage locations on a separate 8-1/2" x 11 " paper including quantities and Material Safety Data Sheets. SEPTIC SYSTEM 0 On-site Septic System — For on-site septic system, provide 2 copies of a current septic design approved by King County Health Department. H:Wpplications'Forms-Applications On Line \2012 Applications'Permit Application Revised - 2-7-12.docx Revised: February 2012 bh Page 2 of 4 PERMIT APPLICATION NOTES — Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER 0 AUTHORIZED AGENT: Signature: Print Name: yu )1' /41 o Mailing Address: 2 .9 3 Z- �! Aur. .3 H:\Applications\Forms-Applications On Line\2012 Applications\Permit Application Revised - 2-7-12.docx Revised: February 2012 bh Day Telephone: City Date: /c2 2 ?*_. 044 pec; State Zip Page 4 of 4 PUBLIC WORKS PERMIT INFO IATION — 206-433-0179 Scope of Work (please provide detailed information): Call before you Dig: 811 Please refer to Public Works Bulletin #1 for fees and estimate sheet. Water District ❑ .. Tukwila ❑ ...Water District #125 ❑ .. Water Availability Provided Sewer District ❑ .. Tukwila ❑ .. Sewer Use Certificate ❑... Highline ❑ ...Valley View ❑...Renton ❑ ...Sewer Availability Provided ❑... Renton ❑... Seattle Septic System: • ❑ On-site Septic System — For on-site septic system, provide 2 copies of a current septic design approved by King County Health Department. Submitted with Application (mark boxes which apply): ❑ .. Civil Plans (Maximum Paper Size — 22" x 34") ❑ .. Technical Information Report (Storm Drainage) ❑ .. Bond ❑... Insurance ❑... Easement(s) Proposed Activities (mark boxes that apply): ❑ .. Right-of-way Use - Nonprofit for less than 72 hours ❑ Right-of-way Use - No Disturbance ❑ .. Construction/Excavation/Fill - Right-of-way ❑ Non Right-of-way ❑ ❑ .. Total Cut ❑ .. Total Fill cubic yards cubic yards ❑ .. Sanitary Side Sewer ❑ .. Cap or Remove Utilities ❑ .. Frontage Improvements ❑ .. Traffic Control El .. Backflow Prevention - Fire Protection Irrigation Domestic Water ❑ .. Permanent Water Meter Size (1) ❑ .. Temporary Water Meter Size (1) ❑ .. Water Only Meter Size ❑ ...Geotechnical Report ❑ ... Maintenance Agreement(s) ❑ .. Traffic Impact Analysis ❑ .. Hold Harmless — (SAO) ❑ .. Hold Harmless — (ROW) 1=1 ... Right-of-way Use - Profit for less than 72 hours ❑ ... Right-of-way Use — Potential Disturbance ❑... Work in Flood Zone ❑... Storm Drainage [I...Abandon Septic Tank 0...Curb Cut ❑... Pavement Cut ❑... Looped Fire Line ❑ .. Sewer Main Extension Public ❑ .. Water Main Extension Public El ❑... Grease Interceptor ❑ ... Channelization El ... Trench Excavation ❑ ... Utility Undergrounding WO # (2) " WO # (3) " WO # WO # (2) " WO # (3) " WO # WO # ❑ .. Deduct Water Meter Size Private ❑ Private ❑ FINANCE INFORMATION Fire Line Size at Property Line Number of Public Fire Hydrant(s) ❑ .. Water 0 .. Sewer ❑ .. Sewage Treatment Monthly Service Billing to: Name: Day Telephone: Mailing Address: City State Zip Water Meter Refund/Billing: Name: Mailing Address: Day Telephone: City State Zip H:Wpplications\Forms-Applications On Line\2012 Applications\Permit Application Revised - 2-7-12.docx Revised: February 2012 bh Page 3 of 4 Cash Register Receipt City of Tukwila DESCRIPTIONS I ACCOUNT QUANTITY PAID PermitTRAK $325.50 D16-0355 Address: 9100 E MARGINAL WAY S Apn: 5422600150 $325.50 DEVELOPMENT $325.50 PERMIT FEE TOTAL FEES PAID BY RECEIPT: R10685 R000.322.100.00.00 0.00 $325.50 $325.50 Date Paid: Tuesday, January 31, 2017 Paid By: YUMO CONSTRUCTION LLC Pay Method: CHECK 1462 Printed: Tuesday, January 31, 2017 1:23 PM 1 of 1 CRSYSTEMS Cash Register Receipt City of Tukwila DESCRIPTIONS ACCOUNT QUANTITY PermitTRAK PAID $557.86 D16-0355 Address: 9100 E MARGINAL WAY S Apn: 5422600150 $557.86 DEVELOPMENT $541.58 PERMIT FEE R000.322.100.00.00 0.00 $325.50 PLAN CHECK FEE R000.345.830.00.00 0.00 $211.58 WASHINGTON STATE SURCHARGE 8640.237.114 0.00 $4.50 TECHNOLOGY FEE $16.28 TECHNOLOGY FEE TOTAL FEES PAID BY RECEIPT: R10207 R000.322.900.04.00 0.00 $16.28 $557.86 Date Paid: Thursday, December 29, 2016 Paid By: YUMO CONSTRUCTION LLC Pay Method: CHECK 1436 Printed: Thursday, December 29, 2016 11:40 AM 1 of 1 CRWSYSTEMS INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila: WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Prosect: / y1eo 4. Lis Ty a of Inspection: 5uec� Ci1J/- Address:/]n / /j� C 41/464d& MY , Date Called: Special Instructions: A, R2er) Date Wante d: / / f a.m p.m. Requester: Phone No: 2S'3 -33?_ -2117 Approved per applicable codes. El Corrections required prior to approval. COMMENTS: Inspector: -16 Date: -2-717 REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. INSPECTION NO. INSPECTION RECORD Retain a copy with permit b!o - ®-s-s PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Proj, ct: I `11)120 t Zt�g Tye of Inspection: SUca DA. ��V,i1 Address: q/ � c-/1 4 // 7 L�"/J S Date Called: Special Instructions: CALL Date Wanted:// 7 21 a.m p.m. Requester: J Phone No: ZS -` 3z--- Zr 77 Approved per applicable codes. Corrections required prior to approval. COMMENTS: ) Accz-5, lourSP-7c/k/ gcle-igbiLr AiSo9Cer?ci Inspector: Date2/1/17 REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Li • hti ng Summary LGT-SUM 2015 Washington State Energy Code Compliance Forms for Commercial Buildings including R2, R3, R4 over 3 stories and all R1 Revised August 2016 Project Info Compliance forms do not require a password to use. Instructional and calculating cells are write - protected. Project Title: 1 - This title will copy onto other forms Date 7/1/2016 Applicant Information. Provide contact information for individual who can respond to inquiries about compliance form information provided. Company Name: Company Address: Z . 7 74-t O b $ % u4 Applicant Name: `kvici tilt Q Vvto Applicant Phone: • ;- 27 zl. z - 2 I "} . Applicant Email: kA {Z `i m p For Building Department Use flLrTl Project Description New Building 0 Addition 0 Alteration 0 Plans Induded Include PROJ-SUM form (included in envelope forms workbook) with lighting complliance forms. Building Additions Refer to Section C502.2.6 for additional requirements. Compliance Method Lighting systems in addition area comply with all applicable provisions as a stand alone new construction project Lighting systems in addition are combined with existing building lighting systems to demonstrate compliance Addition is combined with existing: For interior lighting projects, include new + existing interior lighting fixture wattage in Proposed Lighting Wattage table in LTG -INT -BLD or LTG -INT -SPACE form. For exterior lighting projects, include new + existing exterior lighting fixture wattage in Proposed Tradable and Proposed Non -Tradable Lighting Wattage tables in LTG -EXT form. Interior lighting j Exterior lighting 0 0 0 0 Interior and Exterior Lighting Alterations Select all Lighting Power and Lighting Control elements that apply to the scope of the retrofit project. If project includes a combination of spaces where less than 50% of the existing fixtures are replaced in some spaces, and 50% or more of the fixtures are replaced in others, then provide separate lighting power compliance forms for the two retrofit conditions. Spaces undergoing the same type of retrofit may be combined into one lighting power compliance form. Refer to Section C503.6 for additional requirements. All alteration lighting controls shall be commissioned per C408.3. CORRETION LTR# ni No changes are being made to the interior or exterior lighting systems and existing space uses and configuration are not changed. Lighting Power Interior lighting 50% or more of existing are replaced Less than 50% of existing are replaced' Lamp and/or ballast replacement only — existing total wattage not increased 0 0 Parking garage Exterior lighting O 0 0 O 0 0 0 50% or more replaced - Total lighting power of new + existing -to -remain fixtures shall comply with total LPA per Sections C405.4.2 and C405.5.2. Include new + existing -to -remain fixtures in Proposed Lighting Wattage table in LTG -INT -BLD, LTG -INT -SPACE or LTG -EXT form. Less than 50% replaced - Total lighting power of new + existing -to -remain fixtures shall not exceed the total lighting power prior to alteration. Include new + existing -to -remain fixtures in the Proposed Lighting Wattage table in LTG -INT -BLD, LTG -INT -SPACE or LTG -EXT form. 50% threshold applies to numberof luminaires for interior spaces and parking garages, and total installed wattage for exteri rani ine—a�l�'!1 r/11"f Lighting Control New wiring installed to se fixtures and/or fixtures relo new circuit(s) New or moved lighting pan Interior space is reconfigur luminaires unchanged or re catedCitly of ? viiia PER New wiring or circuit - Fo i i i oRcuairoTs "pe7 caTER occupancy sensor controls trols per C405.2.4 and application specific lighting controls per C405.2.5. For exterior lighting, provide required controls per C405.2.7. New or moved panel - Provide all applicable lighting controls as noted for New Wiring and automatic time switch controls per C405.2.2. Reconfigured interior space - Provide all required lighting controls that apply to a new interior space. Application specific lighting control provisions per C405.2.5 do not apply to reconfigured cdcePE C8VISE arking garage Exterior lighting ted to APPRCI ED Q RECEIV CITY 0P TU ILA J 27/2017 13 JAN g.3. 2P Change of Space Use 0 Existing interior lighting systems in areas under -going a change in space use are upgraded to comply with LPAs for the new space types per Tables C405.4.2(1) or C405.4.2(2). Identify interior spaces requiring LPD upgrade to the current Code in Proposed Lighting Wattage table in LTG -INT -BLD or LTG -INT -SPACE form. bt(rO3SS. ig ting, Y of • r, - n • Elect is - I Per it Check!! t, Pg. LTG -CHK 2015 Washington State Energy Code Compliance Forms for Commercial Buildings including R2, R3, R4 over 3 stories and all R1 Revised August 2016 Project Title: Fill this line out on LGT-SUM Date 7/1/2016 The following information is necessary to check a permit application for compliance with the lighting, motor, and electrical requirements in the Washington State Energy Code, Commercial Provisions. Applicability (yes,no,na) Code Section Component Compliance information required in permit documents Location in Documents Building Department Notes LIGHTING CONTROLS C405.2 Lighting controls, general For all lighting fixtures, indicate lighting control method on plans for spaces and lighting zone(s) served, or exception taken C405.2 Luminaire level lighting controls (LLLC) Indicate on plans all fixtures provided with LLLC in lieu of C405.2 lighting controls; provide description of control capabilities and performance parameters C405.1 Lighting in dwelling units For permanently installed lighting fixtures in dwelling units, indicate lighting control method on plans for spaces and lighting zone(s) served, or demonstrate compliance with high efficacy exception C405.2.3 C405.2.1.1 C405.2.2.2 C405.2.4 C405.2.5 Manual controls Indicate on plans the method of manual lighting control (whether combined with occupancy sensor, automatic light reduction, daylight responsive or specific application controls), location of manual control device and area or specifice application it serves C405.2.2.1 C405.2.2.2 C405.2.3 Manual interior lighting controls Indicate on plans which method of manual 50% lighting load reduction is provided, or whether lighting load is reduced via occupancy sensors or daylight responsive controls C405.2.2 Method of automatic Indicate on plans the method of automatic shut-off control during unoccupied periods (occupancy sensor or time switch) for all lighting zones; shut-off control Indicate locations where automatic shutoff is provided by other methods (occupancy sensor or digital timer switch) or which time switch control exception applies Indicate on plans the spaces served by occupancy sensors; C405.2.1 C405.2.1.1 - Occupancy sensor controls Indicate whether occupancy sensor controls are configured to be manual -on, automatic 50% -on, or serve a space eligible for automatic 100% -on per exception C405.2.1.2 Occupancy sensor controls - warehouses Indicate aisleways and open areas in warehouse spaces provided with occupancy sensor controls that reduce lighting power by 50% C405.2.6 Digital timer switch Indicate required digital timer switch control furiction when control is used C405.2.2.1 Automatic time switch controls Indicate locations of override switches on plans and the lighting zone(s) served, include area sq. ft. Indicate primary and secondary sidelight daylight zone areas on plans, include sq. ft.; C405.2.4.2 Daylight zones - Indicate toplight daylight zone areas on plans, include sq. ft.; 0:74V C405.2.4.3 -r fie!: w•' e Sidelight and toplight C For small vertical fenestration assemblies (rough opening less than 10 percent of primary daylight zone) where daylight responsive controls are not required, provide fenestration area to daylight zone calculation(s) A t ., r til 1 IT" :;t t' + �- y *,i Indicate on plans lighting zone(s) served by daylight responsive controls; r j iia (' C405.2.4 r �' R 'i S aylight responsive controls j Identify sidelight and toplight daylight zones that are not provided with daylight sensing controls and the exception(s) that apply; Indicate on plans the lighting load reduction method - continuous dimming, or stepped dimming that provides at least two even steps between 0%-100% of rated power; Indicate that daylight sensing controls are configured to completely shut off all controlled lights in the lighting zone C405.2.5 Additional controls Specific application lighting controls Identify spaces and lighting fixtures on plans that require specific application lighting controls per this section C405.2.5 - Items 1 &2 Display and accent lighting Indicate on plans that display and accent lighting, and display case lighting are controlled independently from both general area lighting and other lighting applications within the same space; Indicate manual and automatic lighting control method • 2 1 ig ti ., M. • , . • EI- .I P- C - I, P•. 3 LTG -CHK 2015 Washington State Energy Code Compliance Forms for Commercial Buildings including R2, R3, R4 over 3 stories and all R1 Revised August 2016 Project Title: Fill this line out on LGT-SUM Date 7/1/2016 The following information is necessary to check a permit application for compliance with the lighting, motor, and electrical Washington State Energy Code, Commercial Provisions. requirements in the Applicability (yes,no,na) Code Section Component Compliance information required in permit documents Location in Documents Building Department Notes INTERIOR LIGHTING POWER & EFFICACY Include all luminaires in lighting fixture schedule; indicate fixture types, lamps, ballasts, and manufacturer's rated watts per fixture; C405.4.1 C405.4.1 Total connected Identify spaces eligible for lighting power exemption on plans and in compliance forms; indicate the exception applied; interior lighting power Identifylighting equipment eli eligible for lighting g power exemption in fixture schedule and in compliance forms; indicate the exception applied; Indicate that exempt lighting equipment is in addition to general area lighting and is controlled independently C405.3 Exit signs Indicate location of exit signs on plans and rated watts per fixture in lighting fixture schedule (maximum 5 watts per fixture) C405.1 Lighting in dwelling units lamp efficacy If high efficacy exception is applied to permanently installed lighting fixtures in dwelling units, indicate in lighting fixture schedule if lamps in fixtures are high efficacy per R404.1. Calculate percentage of fixtures with high efficacy lamps in project (min 75% to comply with exception). C406.3 Reduced lighting power density - dwelling unit lamp efficacy For project with dwelling units, to comply with additional efficiency package option indicate in lighting fixture schedule if lamps in fixtures have efficacy rating of 60 lumens per watt or more. Calculate percentage of fixtures with lamps that have this efficacy rating (min 95% to comply with option). Lighting Power Calculation - Indicate compliance path taken C405.4.2.1 Building Area Method Complete required compliance forms — proposed wattage per building area does not exceed maximum allowed wattage per building area. Identify locations of building areas on plans C405.4.2.2 Space -By -Space Method Complete required compliance forms — total proposed wattage does not exceed maximum allowed wattage. Identify locations of space types on plans, including retail display areas, lobby art & exhibit display areas, and ceiling heights as applicable C406.3 Reduced lighting power density To comply with additional efficiency package option, demonstrate in compliance forms that total connected interior lighting wattage is 75% less than the total maximum allowed lighting wattage via Building Area Method or Space -By -Space Method EXTERIOR LIGHTING POWER & EFFICACY C405.5.2 Total connected exterior lighting power Include all luminaires in lighting fixture schedule; indicate fixture types, lamps, ballasts, and manufacturer's rated watts per fixture; Identify exterior applications eligible for lighting power exemption on plans and in compliance forms; indicate exception applied; Indicate that exempt exterior lighting is controlled independently from non-exempt exterior lighting; include exception claimed for each fixture or group of fixtures under exception category Table C405.5.2(1) Exterior lighting zone Indicate building exterior lighting zone as defined by the AHJ C405.5.1 Exterior building grounds lighting For building grounds fixtures rated at greater than 100 watts that are complying based on efficacy, indicate rated lamp efficacy (in lumens per watt) in fixture schedule C405.5.2 Exterior lighting power calculations Complete required compliance form — proposed wattage for exterior lighting plus base site allowed does not exceed maximum allowed Exterior Lighting 2015 Washington State Energy Code Compliance Forms for Commercial Buildings including R2, R3, R4 over 3 stories and all R1 LTG -EXT Revised August 2016 Project Title: Fill this line out on LGT-SUM Date 7/1/2016 Exterior Lighting Zone Table C405.5.2(1) Specified by jurisdiction. 0 Zone 1 0 Zone 2 0 Zone 3 0 Zone 4 Zone selection required to enable LTG -EXT form For Building Department Use Calculation Area 0 0 Addition - 0 Addition stand alone + existing O Alteration with < 50% 0 Alteration with z 50% ext. ext. wattage replaced wattage replaced Building Grounds Applies to luminaires > 100 Watts • Efficacy > 80 lumens/watt ■ Exemption ■ Controlled by motion sensor Tradable Maximum Allowed Lighting Wattage NOTE' g g g Base Site Allowance: 0 Tradable Surfaces Surface Description Area (fr), perimeter (If) or # of items Allowed watts per ft2 or per If HIIOweo vvatts x ft2 (or x If) Total Allowed Tradable + Site Allowance Watts: raaabie rroposea Lignting wattage Tradable Surface Fixture Description NOTE 3, a Number of Fixtures Watts per Fixture NOTE 5 Watts Proposed Allowed Watts per ft2 or per If Allowed Watts x ft2 (or x If) Total proposed tradable vietts may not exceed the sum of total allowed tradable Total Proposed Tradable Watts: watts plus the base site alloviance. Any base site allowance not needed to make tradable watts comply can be applied to individual non -tradable Non- I raaaDie Maximum Allowed Lighting Watta a ""'' g g g Site Allowance Remaining: 0 Non -Tradable Surfaces Surface Description Area (ft2), perimeter (If) or # of items Allowed Watts per ft2 or per If Allowed Watts x ft2 (or x If) on- lraaable 1 roposea Lignting wattage Non -Tradable Surface Fixture Description NOTE 3, 4 Number of Fixtures Watts per Fixture NOTE 5 Watts Proposed Non -tradable proposed watts may not exceed allowed watts for any individual surface unless the total excess watts for all non -tradable surfaces are less than the remaining site allowance. Non -Tradable Watts Exceeding LPA: Remaining Site Allowance: Exterior Lighting Note 1 - List all unique exterior sufaces per Table C405.5.2(2) that occur in the project scope. Select exterior surface categories from drop dovui menu. Note 2 - List all proposed lighting fixtures including existing -to -remain fixtures. Note 3 - For proposed Fixture Description, indicate fixture type, lamp type, number of lamps in the fixture, and ballast type (if applicable). Note 4 - Existing -to -remain fixtures shall be included in the Tradable and Non -Tradable Proposed Lighting Wattage tables in the same manner as new fixtures. identify as existing in fixture description. Note 5 - For proposed Watts/Fixture enter the luminaire wattage for installed lamp and ballast using manufacturer or other approved source. For luminaires with screwin lamps, enter the manufacturer's listed maximum input wattage of the fixture (not the lamp wattage). For low Instructions for Electronic Forms, pg 2 2015 Washington State Energy Code Compliance Forms for Commercial Buildings including R2, R3, R4 over 3 stori Revised August 2016 Interior LTG Building Area Method For projects complying via the Building Area Method, provide the total gross interior area for each Building Area Type in the Maximum Allowed Lighting Wattage table using the drop down menu. Assign a Building Area using the drop menu for each lighting fixture type defined in the Proposed Lighting Wattage table. The worksheet will total all fixtures assigned to each Building Area. Each Buidling Area shall comply independently. Interior LTG Space -By- Space Method For projects complying via the Space -By -Space Method, provide total gross interior area for each Space Type in the Maximum Allowed Lighting Wattage table using the drop down menu. For Atriums and any space utilizing the additional lighting wattage allowance based on ceiling height per Footnotes d thru f, provide total gross interior area and ceiling height (above finished floor) in the Maximum Allowed Lighting Wattage table. All Display lighting shall be entered in the LTG -INT -DISPLAY worksheet. Results from this worksheet automatically transfer to the LTG -INT -SPACE worksheet in the assigned locations under Retail Display Allowance, Lobby Art/Exhibit Allowance and Proposed Retail Display Lighting cells. Interior LTG Retail Display For projects with eligible Retail Sales display lighting that is in addition to Retail Sales general area lighting, select the Retail Display category per Section C405.4.2.2.1 from the drop down menu provided, and enter the total gross interior area of the footprint illuminated by display lighting in the Maximum Allowed Retail Display Lighting Wattage table. Assign a corresponding Retail Display category to each lighting fixture type defined in the Proposed Retail Display Lighting Wattage table using the drop down menu. For projects with eligible Lobby Art/Exhibit display lighting that is in addition to Lobby general area lighting, enter a unique name for each Lobby that this allowance will be applied to, and enter the total gross interior area of the Lobby in the Maximum Allowed Lobby Art/Exhibit Display Lighting Wattage table. Assign a corresponding Lobby to each lighting fixture type defined in the Proposed Lobby Art/Exhibit Display Lighting Wattage table. The total Retail Display and Lobby Art/Exhibit Display gross interior areas entered in the LTG -INT -DISPLAY worksheet may not exceed the total Retail Sales and Lobby Art/Exhibit Display gross interior areas entered in the LTG -INT -SPACE worksheet. Exterior LTG Provide square -foot surface area, perimeter linear feet, or number of items for each Surface Type in the Tradable and Non - Tradable Maximum Allowed Lighting Wattage tables using the drop down menus. Assign a Surface using the drop menu for each exterior lighting fixture type defined in the Tradable and Non -Tradable Proposed Lighting Wattage tables. Printing The forms should print on any printer supported by your operating system. You will need to have the following TrueType fonts installed under Windows: Arial, Times New Roman, Courier New and Wingdings. These are all standard Windows fonts. If you are losing form details when printing, you may have a shortage of printer memory. Try printing problem pages individually. By default, only the active worksheet is printed. To print more than one worksheet at a time, open your print set-up menu and select either the page range you wish to print or Entire Workbook. Forms (worksheets) in a workbook may not be deleted because the file is locked. Blank Forms To print blank forms, delete all of the heading information at the beginning of LTG -SUM. For less than 50% alterations, select the Calculation area in the LTG -INT -SPACE form before printing. For each radio button group there is a button labeled "Clear." Clicking this button will clear the other buttons so that they will print as empty circles. The "Clear" button will not print. End of Instructions for Electronic Forms Interior Disp!ey Lighting - Space -by -Space 20 r, • " ate Energy Code Compliance Forms for Commercial Buildings including R2, R3, R4 over 3 stories and all R1 general area7rg tlnq, maybe entered in tis table. LTG-NT.,D!SPLAY Revised July 2016 ProOlft ntlekobby 4:4Mititithgia/AKIE/t4Aftmlf automatically entered in LTG -INT -SPACE. Date 7/1/2016 General Note - In Lobby areas, an additional vlattage alloviance is permitted for lighting installed specifically for the purpose of highlighting art and exhibits. Only Lobby areas Wth eligible display lighting may use this additional allovience. Proposed display lighting for each Lobby area may not exceed this alloNance. Maximum Allowed Lobby Art/Exhibit Display Lighting Wattage For Building Department Use Lobby Area NOTE s Lobby Description including (plan # & room #) Gross Interior Area in ft2 Maximum Display Watts Allowed Per Area NOTE 10 Proposed Display Lighting Total Per Area NOTE 11 Total Lobby with Display Area Total Lobby Art/Exhibit Display Allowance NOTE 13 Proposed Lobby Art/Exhibit Display Lighting Wattage NOTE 12 Lobby Area Location (plan #, room #) Fixture Description NOTE 5 Number of Fixtures Watts per Fixture NOTE s Watts Proposed Total Lobby Art/Exhibit Proposed Display Watts luminaires Wth screwin lamps, enter the manufacturer's listed maximum input wattage of the fixture (not the lamp wattage). For low voltage lighting, enter the wattage of the transformer. For line voltage track/busway systems, enter the larger of the attached luminaire wattage 50 watts/lineal foot, or enter the wattage limit of permanent current limiting device. Note 7 - Proposed Wattage for each Building Area type shall not exceed the Allowed Wattage for that Building Area type. Trading wattage between Building Area types is not allowed under the Building Area Method compliance path. Note 8 - Calculation Area Details: a. Lighting fixtures in a building addition may comply as a stand alone project, or they may be combined Wth the overall existing building t NW Garden Supply To: Ms. Dunning, Mr. Bill Rambo, Mr. Jerry Hight (City of Tukwila) From: NW Garden Supply dba Hydro 4 Less CC: Kevin Kooyman (Property Manager), Jeff Greathouse (Contractor), Mike Stockwell (Tenant Insurance Adjustor) Date: 08/07/2017 Re: Correction Letter #1 — Permit D160355 Mr. Rambo and Mr. Hight, 9100 E Marginal Way S Seattle, Wa 98108 Phone 206-767-8082 Email nwgardensupply@gmail.com RECEIVED AUG 14 2017 Community Development I am writing in regard to the attached Correction Letter which was hand -delivered to the owner of this company, Jimmy Huang, today. It has come to our attention that a contractor hired to do work at our premises has not filed or responded to permit requirements and we are at risk of having a Stop Work Order placed at our retail store. We rent this property from JSH Properties who has enlisted ServPro to do work after a fire. To my understanding, ServPro contracted Yuriy Momotyuk to do work at this property. Being the tenant, I do not know what services Mr. Momotyuk was providing or that any permits were not filed properly until today. NW Garden Supply is ready and able to do anything necessary to comply. We are working diligently with JSH Properties and ServPro to get this issue rectified. We had no direct working relationship with Mr. Momotyuk. I am including all involved parties' contact information so we can all work diligently to rectify this issue so I might keep my retail store running and all staff and customers in a safe environment. I am respectfully requesting an extension of any sort you might offer while involved parties work to provide the City of Tukwila with anything they might need for our business address to be in compliance. I will also send a copy of this letter to your offices via Priority mail. Involved parties: Kevin Kooyman —JSH Properties - C: (206) 419-7814 kevink@ishproperties.com Jeff Greathouse — ServPro — C: (206) 947-7154 ieff@servproseattlenw.com Mike Stockwell — Young & Associates — C: (503) 410-6748 mstockwell@voungonline.com Respectfully, Sherri Danner C: (425-931-5532) Retail Manager E -Mail: NWGardenSupply@gmail.com Phone: 206-767-8082 7/3/2017 City of Tukwila Department of Community Development YURIY MOMOTYUK 27327 48 AVE S KENT, WA 98032 RE: Permit No. D16-0355 HYDRO FOR LESS 9100 E MARGINAL WAY S Dear Permit Holder: Allan Ekberg, Mayor Jack Pace, Director In reviewing our current records, the above noted permit has not received a final inspection by the City of Tukwila Building Division. Per the International Building Code, International Mechanical Code, Uniform Plumbing Code and/or the National Electric Code, every permit issued by the Building Division under the provisions of these codes shall expire by limitation and become null and void if the building or work authorized by such permit has not begun within 180 days from the issuance date of such permit, or if the building or work authorized by such permit is suspended or abandoned at any time after the work has begun for a period of 180 days. Your permit will expire on 8/2/2017. Based on the above, you are hereby advised to: 1) Call the City of Tukwila Inspection Request Line at 206-438-9350 to schedule for the next or final inspection. Each inspection creates a new 180 day period, provided the inspection shows progress. -or- 2) Submit a written request for permit extension to the Permit Center at least seven(7) days before it is due to expire. Address your extension request to the Building Official and state your reason(s) for the need to extend your permit. The Building Code does allow the Building Official to approve one extension of up to 180 days. If it is determined that your extension request is granted, you will be notified by mail. In the event you do not call for an inspection and/or receive an extension prior to 8/2/2017, your permit will become null and void and any further work on the project will require a new permit and associated fees. Thank you for your cooperation in this matter. Sincerely, Bill Rambo Permit Technician File No: D16-0355 6300 Southcenter Boulevard Suite #100 • Tukwila, Washington 98188 • Phone 206-431-3670 • Fax 206-431-3665 January 18, 2017 City of Tukwila Department of Community Development YURIY MOMOTYUK 27327 48 AVE S KENT, WA 98032 RE: Correction Letter # 1 DEVELOPMENT Permit Application Number D16-0355 HYDRO FOR LESS - 9100 E MARGINAL WAY S Dear YURIY MOMOTYUK, Allan Ekberg, Mayor Jack Pace, Director This letter is to inform you of corrections that must be addressed before your development permit can be approved. All correction requests from each department must be addressed at the same time and reflected on your drawings. I have enclosed comments from the following departments: BUILDING DEPARTMENT: KC ELLIS at (206)-431-3677 if you have questions regarding these comments. • Complete and return a NREC lighting summary. See attached. Please address the comments above in an itemized format with applicable revised plans, specifications, and/or other documentation. The City requires that two (2) sets of revised plan pages, specifications and/or other documentation be resubmitted with the appropriate revision block. In order to better expedite your resubmittal, a 'Revision Submittal Sheet' must accompany every resubmittal. I have enclosed one for your convenience. Corrections/revisions must be made in person and will not be accepted through the mail or by a messenger service. If you have any questions, I can be reached at (206) 433-7165. Sincerely, Rachelle Ripley Permit Technician File No. D16-0355 6300 Southcenter Boulevard Suite #100 • Tukwila Washington 98188 • Phone 206-431-3670 • Fax 206-431-3665 PERMIT COORD COPY- PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: D16-0355 DATE: 01/23/17 PROJECT NAME: HYDRO FOR LESS SITE ADDRESS: 9100 E MARGINAL WAY S Original Plan Submittal X Response to Correction Letter # 1 Revision # Revision # before Permit Issued after Permit Issued DEPARTMENTS: Building Division Public Works ❑ Fire Prevention Structural CI Planning Division ❑ Permit Coordinator n w PRELIMINARY REVIEW: Not Applicable n (no approval/review required) DATE: 01/24/17 Structural Review Required REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: Approved Corrections Required ❑ Approved with Conditions Denied (corrections entered in Reviews) (ie: Zoning Issues) DUE DATE: 02/21/17 111 111 Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg 0 Fire 0 Ping ❑ PW 0 Staff Initials: 12/18/2013 PERMIT COORD COPY PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: D16-0355 DATE: 12/29/16 PROJECT NAME: HYDRO FOR LESS SITE ADDRESS: 9100 E MARGINAL WAY S X Original Plan Submittal Revision # before Permit Issued Response to Correction Letter # Revision # after Permit Issued DEPARTMENTS: Building Divisio • NIN Public Works �rM PCW Fire Prevention Structural "41- 1-317 Planning Division III ❑ Permit Coordinator 1111 PRELIMINARY REVIEW: Not Applicable D (no approval/review required) DATE: 01/03/17 Structural Review Required REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: DUE DATE: 01/31/17 Approved Corrections Required ❑ Approved with Conditions ❑ ❑ Denied (corrections entered in Reviews) (ie: Zoning Issues) a Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only VI CORRECTION LETTER MAILED: I6Departments issued corrections: BI g Fire 0 Ping ❑ PW ❑ Staff Initials: l'11/1 12/18/2013 Date: City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Web site: http://www.TukwilaWA.gov REVISION SUBMITTAL Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fax, etc. Plan Cheek/Permit Number: D16-0355 ❑ Response to Incomplete Letter # ® Response to Correction Letter # 1 ❑ Revision # after Permit is Issued ❑ Revision requested by a City Building Inspector or Plans Examiner ❑ Deferred Submittal # Project Name: HYDRO FOR LESS Project Address: 9100 E MARGINAL WAY S RECEIVED CITY OF TUKWILA JAN 232017 PERMIT CENTER Contact Person: `'� Ut OC'E`O �� Phone Number: 25 s -; Summary of Revision: ICe c lJ-('-5 Sl t vvl 144 0(7 Sheet Number(s): "Cloud" or highlight all areas of revision including date of revisi n C � n Received at the City of Tukwila Permit Center by: N ---Entered in TRAKiT on C:\Users\Rachelle-R\Desklop\Revision Submittal Form - D16-0305.doc Revised: August 2015 YUMO CONSTRUCTION LLC 1-lome Espanol Contact Safety & Health Claims & Insurance 0 Washington State Department of Labor & Industries Search L&I Page 1 of 2 A -Z Index Help My LE Workplace Rights Trades & Licensing YUMO CONSTRUCTION LLC Owner or tradesperson Principals MOMOTYUK, YURIY, PARTNER/MEMBER MOMOTYUK, VALENTINA, PARTNER/MEMBER MOMOTYUK, OREST, PARTNER/MEMBER RADOVETS, NAZAR, PARTNER/MEMBER Doing business as YUMO CONSTRUCTION LLC WA UBI No. 602 530 533 27327 48TH AVE S KENT, WA 98032 253.332-2177 KING County Business type Limited Liability Company License Verify the contractor's active registration / license / certification (depending on trade) and any past violations. Construction Contractor Active. ........_................_..._...............__..................... Meets current requirements. License specialties GENERAL License no. YUMOCCL9520T Effective — expiration 09/30/2005— 02/28/2018 Bond ................. American Contractors Indem CO Bond account no. 100279615 $12,000.00 Received by L&I Effective date 07/10/2015 07/07/2015 Expiration date Until Canceled Bond history Insurance ......................... Contractors Bonding & Insuranc $1,000,000.00 Policy no. c11sk1360 Received by L&I Effective date 06/22/2016 06/20/2016 Expiration date 06/20/2017 Insurance history Savings Help us improve https://secure.lni.wa.gov/verify/Detail.aspx?UBI=602530533&LIC=YUMOCCL952OT&SAW= 1/31/2017 YUMO CONSTRUCTION LLC No savings accounts during the previous 6 period. Lawsuits against the bond or savings No lawsuits against the bond or savings accounts during the previous 6 year period. L&I Tax debts No L&l tax debts are recorded for this contractor license during the previous 6 year period, but some debts may be recorded by other agencies. License Violations ..._.................................................. No license violations during the previous 6 year period. Workers' comp Do you know if the business has employees? If so, verify the business is up-to-date on workers' comp premiums. L&I Account ID 101,089-01 ................................. Doing business as YUMO CONSTRUCTION LLC Estimated workers reported Quarter 4 of Year 2016 "0" Workers L&I account representative T3 / REAGAN MOREY (360)902-5135 - Email: MREA235@Ini.wa.gov Account is current. Workplace safety and health Check for any past safety and health violations found on jobsites this business was responsible for. Page 2 of 2 © Washington State Dept. of Labor & Industries. Use of this site is subject to the laws of the state of Washington. Help us improve https://secure.lni.wa.gov/verify/Detail.aspx?UBI=602530533&LIC=YUMOCCL9520T&SAW= 1/31/2017 A A A01 FIXED 36"X1O3';FROM SLAB 0» /i///l /, OFFICE Lie. k wee' e c11444 rice fru,tx fttreo,t9-tat +yr,r 30 1/2"X46 ;FROM SLAB 36" co OFFICE $QFe i &-/k.SS r OPENING 41" BEAM10'X36" BOT 6,13'--7" E -4X12 RAFTER 1936"0.C. FIXED 73"X46",FROM SLAB 36" SPACE FIXED (3)38'X65 ;FROM SLAB 36" PORCH STORAGE 30 RESTROOM <AA01 5Y-2" EXISTING VERIFY SUSPENDED CEILING ELEV. sta I EXISTING FLOOR ELEV 2EVISIONS 6�o c' made to the scope approval of Division. NOTE: require a new plan submittal .I in,:lude additional plan review fees. LI ct EXIST/NG VERIFY AUG 02 Z?$?E LE COPY Permit Plan revia=.r is subject to errors and omissions. Approval of COri6iW lion documents does not e ;.itile'ie:e the violation of any adopted code or ordinance. Recciipt of approved Field Copy and conditions i /acknowled: =d: By: Date: City of Tukwila BUILDING DIVISION EXISTING MAIN FLOOR PLAN scale 1/4" = 1'-0" EXISTING BEAM 10"X36" EXISTING ROOF RAFTERS BRACING WIRE COMPRESS110N STRUT EX/S77NG WALL EXISTING CONCRETE SLAB BOT. EXISTING BEAM 23 A02 7EXIS77NG WALL F r ^dliT ffelVochanical YEcctrical l 'Plurnbing i'Cas Piping ;:City 01 Tukwila E31,.±':_r e^ DIVISION REVIEWED FOR CODE COMPLIANCE APPROVED JAN 2 7 2017 City of Tukwila BUILDING DIVISION Dlb- O35s SCHEMATIC SECTION. A -A scale 1/4" = 1'-0" RECEIVED CITY OF T UKWILA DEC 292016 PERMIT CENTER ArchStudio"Y.SHADYRYA" 22420 6th PL W Bothell,WA. T.206-240.7329 >- Q Zco L1.1W< T- >0 Z o a0_,.,.„, aC 2ou-i er7. Zu co <0 t Z W W o I -- o 0 Z 0 0 0 J U- 00 Z I— co X W 12/28/2016 ) 0 1 rJ #;X ) CA A01 ><- x ) See figure (33.4.1-8 for connections of bracint hanger wire to the structure above Compression strut (see frfotc) 12 gauge bracing wire +w/rain. 4 tight turns in 1.1/2" both ends of wire - connect to main runner (4 total at 90' ) Main runne, Cross runnel 12 gauge vertical hanger wire at 4' - 0" each way with minimum 3 tight turns in 1-1/2" both ends (typical) 2" (max.) from bracing wires to compression strut and cross runner SUSPENDED SCHEME, TYP. scale N.T.S. Note: Compression strut shall not replace hanger wire. Compression strut consists of a steel section attached to main runner with 2 - #12 sheet metal screws and to structure with 2 - #12 screws to wood or 1/4" min. expansion anchor to structure. Size of strut is dependent on distance between ceiling and structure (lir 5 200). A 1" diameter conduit can be used for up to 6, a 1-5/8" X 1-1/4" metal stud can be used for up to 10' <AA01 v i L ><- SCHEMATIC CEILING PLAN scale 1/4" = 1'-0" CEILING NOTES. 1. INSTALL ALL SUSPENDED ACOUS11CAL CEILING WORK with THE REQUIREMENTS OF ASTM C635, ASTM C636 ANDASTM E580 2 GRID SYSTEM TO BE INTERMEDIATE DUTY EXPOSED TEE BAR SYSTEM COLOR WHITE ,OR MATCH TO EXISITNG. SYSTEM SHALL BE DONN DX24 AS MANUFACTURED BY DONNORPORATTON OR EQUAL ACOUS11CAL LAY -IN PANELS SHALL BE 2048' (T0 MATCH EXISTING PANELS) IN SIZE UNLESS OTHERIOSE NOTED ON DRAWINGS PANELS SHALL BE %" THICK "MINABOARD° RANDOM FISSURED AS MANUFACTURED BY ARMSTRONG OR EQUAL 4. USE 12 GAUGE GALVANIZED WIRE HANGERS MINIMUM. ANCHOR TO ROOF STRUCTURAL OR PANELS. PROI4DE SEISMIC BRACING AS REQUIRED. SPACE ANCHORS AS REQUIRED TO OBTAIN RIGID FRAMING SYSTEM PERMANENTLY TREE OF SAGGING. 5. LIGHT FIXTURES OR EQUIPMENT SHALL BE FASTENED TO THE STRUCTURE ABOVE 11TH TWO /12 GAUGE WIRES WHICH MAY BE SLACK. LATERAL FORCE BRACING MEMBERS SHALL BE SPACED A MINIMUM OF 6 INCHES FROM ALL HORIZONTAL PIPING OR DUCT WORK THAT IS NOT PROVIDED WITH BRACING RESTRAINTS FOR HORIZONTAL FORCES BRACING ARES SHALL BE ATTACHED TO 1HE GRID AND TO THE STRUCTURE IN SUCH A MANNER THAT THEY CAN SUPPORT A DESIGN LOAD OF NOT LESS THAN 200 POUNDS OR THE ACTUAL DESIGN LOAD, WHICHEVER IS GREATER, W1111 A SAFETY FACTOR OF 2. AT EACH LIGHT FIXTURE PROVIDE (2) No 12 WIRES SECURING FIXTURE TO THE BUILDING STRUCTURE (VERITY LIGHT WEIGHT).SEE IBC TABLE 25-A LEGEND: EXISTING 4' FLUORESCENT LIGHT FIXTURE WITH (2)40 WATT BULBS W/ INDEPENDENTLY SWITCHED BALLAST EXISTING FAN COMPRESSTION STRUT Alternate strut location w/o nail. Notching permitted only at runner 3/4" min. clearance (panel free to slide) Lesser of 8" or 1/4 * length of end span Main or cross runner Acoustic panel Slotted angle spacer with horizontal 6d ringshank nail (nail head toward span) Wail connection -anchor -_. C FIGURE 6.3.4.1-8 scale N.T.S. Lesser of 8" or 1/4 length of end span 1-1/2" `` Pop rivet (or qui `Wall angle Wall connection -anchor 12 gauge hanger wire Min. 3 tight turns Main or 'Cross runner f Acoustic panel fled perimeter support clip) FIGURE 6.3.4.1-8a scale N.T.S. 1/4" diameter screwy eye with full thread embedded (1-1/4" min.) Install In direction of wire Wood Joist or Rafter racing wire Mr ger wire -- 1/4" diameter screw eye (1-1/4" min.) Wood ]oast or Rafter AUG 02 2017 FIGURE 6.3.4.1-11 scale N.T.S. bU'03sS REVIEWED FOR CODE COMPLIANCE APPROVED JAN 2 7 2017 City of Tukwila BUILDING DIVISION RECEIVED CITY OF d UKWIL/ DEC 292016 PERMIT CENTER ArchStudio"Y.SHADYRYA" 22420 6th PL W Bothell,WA. T.206-240.7329 z 0 z J_ W 0 0 W U w U- z W 12/28/2016 Q 0 A02