Loading...
HomeMy WebLinkAboutPermit M16-0011 - FAMILY FUN CENTER - ROOFTOP UNITSFAMILY FUN CENTER 7300 FUN CENTER WAY M16-0011 City of Tukwila ' Department of Community Development • 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-438-9350 Web site: http://www.TukwilaWA.Rov MECHANICAL PERMIT Parcel No: 2423049063 Permit Number: M16-0011 Address: 7300 FUN CENTER WAY Issue Date: 2/23/2016 WA Cities Electrical Code: 2014 Permit Expires On: 8/21/2016 Project Name: FAMILY FUN CENTER 2014 Owner: 2012 WA State Energy Code: Name: FAMILY FUN CENTERS TUKWILA 2012 Address: 7300 FUN CENTER WAY, TUKWILA, WA, 98188 Contact Person: Name: ALEX BURKHART Phone: (206) 763-1744 Address: 727 S KENYON ST, SEATTLE, WA, 98108 Contractor: Name: EVERGREEN REFRIGERATION LLC Phone: (206) 763-1744 Address: 727 S KENYON ST, SEATTLE, WA, 98108 License No: EVERGRL954112 Expiration Date: 1/6/2018 Lender: Name: Address: DESCRIPTION OF WORK: INSTALLATION OF (4) ROOFTOP UNITS, (4) EXHAUST FANS, DUCT WORK, AND GRILLES/DIFFUSERS Valuation of Work: $64,388.00 Fees Collected: $1,037.02 Type of Work: NEW Electrical Service Provided by: PUGET SOUND ENERGY Fuel type: GAS Water District: TUKWILA Sewer District: TUKWILA SEWER SERVICE Current Codes adopted by the City of Tukwila: International Building Code Edition: 2012 National Electrical Code: 2014 International Residential Code Edition: 2012 WA Cities Electrical Code: 2014 International Mechanical Code Edition: 2012 WAC 296-4613: 2014 Uniform Plumbing Code Edition: 2012 WA State Energy Code: 2012 International Fuel Gas Code: 2012 Permit Center Authorized Signature: `� Date: // �� I hearby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this development permit and agree to the conditions attached to this permit. Signa Print Date: Z) ` This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: Work shall be installed in accordance with the approved construction documents, and any changes made during construction that are not in accordance with the approved construction documents shall be resubmitted for approval. 2: All permits, inspection record card and approved construction documents shall be kept at the site of work and shall be open to inspection by the Building Inspector until final inspection approval is granted. 3: Readily accessible access to roof mounted equipment is required. 4: All construction shall be done in conformance with the Washington State Building Code and the Washington State Energy Code. 5: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of this requirement. 6: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206-431-3670). 7: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center. 8: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 9: ***MECHANICAL PERMIT CONDITIONS*** 10: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431-3670). 11: Manufacturers installation instructions shall be available on the job site at the time of inspection. 12: The attached set of mechanical plans have been reviewed by The Tukwila Fire Marshals Office and are acceptable with the following concerns: 13: H.V.A.C. units rated at greater than 2,000 cfm require auto -shutdown devices. These devices shall be separately zoned in the alarm panel and local U.L. central station supervision is required. (City Ordinance #2437) 14: H.V.A.C. systems supplying air in excess of 2,000 cubic feet per minute to enclosed spaces within buildings shall be equipped with an automatic shutoff. Automatic shutoff shall be accomplished by interrupting the power source of the air -moving equipment upon detection of smoke in the main return -air duct served by such equipment. Smoke detectors shall be labeled by an approved agency for air -duct installation and shall be installed in accordance with the manufacturer's installation instructions. (IMC 606.1, 606.2.1) 15: Remote indicator lights are required on all above ceiling smoke detectors. (City Ordinance #2437) 16: Duct smoke detectors shall be capable of being reset from a single point near the alarm panel. (City Ordinance #2437) 17: Duct detectors shall send a supervisory signal only upon activation. (City Ordinance #2437) 18: All new fire alarm systems or modifications to existing systems shall have the written approval of The Tukwila Fire Prevention Bureau. No work shall commence until a fire department permit has been obtained. (City Ordinance #2437) (IFC 901.2) 19: An electrical permit from the City of Tukwila Building Department Permit Center (206-431-3670) is required for this project. 20: Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (City Ordinances #2436 and #2437) 21: Any overlooked hazardous condition and/or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. 22: These plans were reviewed by Inspector 511. If you have any questions, please call Tukwila Fire Prevention Bureau at (206)575-4407. PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 1400 FIRE FINAL 0703 MECH EQUIP EFF 1800 MECHANICAL FINAL 0609 PIPE/DUCT INSULATION 0705 REFRIGERATION EQUIP 0701 ROUGH -IN MECHANICAL 0702 SMOKE DETECTOR TEST CITY OF TUKW. i • Community Development Department Permit Center • 6300 Soutlicenter Blvd., Suite 100 Tukwila, WA 98188 http://ww\N,.TukwilaWA.goN, SITE LOCATION Mechanical Permit No. Project No. Date Application Accepted: Date Application Expires: (For office use only) MECHANICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **please print** King Co Assessor's Tax No.. 2423049063 Site Address: 7300 Fun Center Way Suite Number: Floor: Tenant Name: Family Fun Center New Tenant: ❑ .....Yes m..No PROPERTY OWNER Name: Family Fun Centers Address: 7300 Fun Center Way City: Tukwila State: WA Zip: 98188 CONTACT PERSON — person receiving all project communication Name: Alex Burkhart Address: 727 South Kenyon St. City: Seattle State: WA Zip: 98108 Phone: (206) 763-1744 Fax: (206) 763-2389 Email: alexb@evergreenhvac.com Valuation of project (contractor's bid price): $ 64,388 Describe the scope of work in detail: MECHANICAL CONTRACTOR INFORMATION Company Name: Evergreen Refrigeration Address: 727 South Kenyon St. City: Seattle State: WA Zip: 98108 Phone: (206) 763-1744 Fax: (206) 763-2389 Contr Reg No.: EVERGRL954R2 Exp Date: 01/06/2016 Tukwila Business License No.: BUS -0992877 Installation of four (4) rooftop units, four (4) exhaust fans, ductwork, and grilles/diffusers. Use: Residential: New .......... ❑ Replacement ........ ❑ Commercial: New .......... Replacement ........ ❑ Fuel Type: Electric..... ❑ Gas ....... m Other:_ H:\Applicalions\Forms-Applications On 1-ine\2011 Applications\Mechanical Pennit Application Revised 8-9-1 I.docx Revised: August 2011 Page 1 of 2 bb Indicate type of mechanical work being installed and the quantity below: Unit Type Qty Furnace <100k btu Furnace >100k btu 4 Floor furnace 4 Suspended/wall/floor mounted heater Appliance vent Repair or addition to heat/refrig/cooling system Air handling unit <10,000 cfm 4 Unit Type Qty Air handling unit >I0,000 cfin cooler 4 —Evaporator Ventilation fan connected to single duct 4 Ventilation system Hood and duct Incinerator — domestic Incinerator — comm/industrial PERMIT APPLICATION NOTES - Unit Type Qty Fire damper Diffuser 4 Thermostat Wood/gas stove Emergency enerator Other mechanical equipment Boiler/Compressor Qty 0-3 hp/ 100,000 btu 3-15 h /500,000 btu 15-30 hp/1,000,000 btu 30-50 hp/1,750,000 btu 50+ h /1,750,000 btu Value of construction — in all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the permit center to comply with current fee schedules. Expiration of plan review — applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The building official may grant one extension of time for additional periods not to exceed 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT BUILDING OWNER OR AUTHORIZED AGENT: Signature: Print Name Alex Burkhart Date: 1/ m (is S Day Telephone: (206) 763-1744 Mailing Address: 727 South Kenyon St. Seattle, WA 98108 City State Zip H:\Applications\Forms-Applications On Line\2011 Applications\Mechanical Permit Application Revised 8-9-1 I.docx Revised: August 2011 Page 2 of 2 bit DESCRIPTIONS PermitTRAK • ClUANTITY PAID $1,254.61 EL16-0057 Address: 7300 FUN CENTER WAY Apn: 2423049063 $90.83 ELECTRICAL $86.50 PERMIT FEE MULTI-FAM/COMM R000.322.101.00.00 0.00 $86.50 TECHNOLOGY FEE $4.33 TECHNOLOGY FEE R000.322.900.04.00 0.00 $4.33 M16-0011 Address: 7300 FUN CENTER WAY Apn: 2423049063 $1,037.02 MECHANICAL $997.13 PERMIT ISSUANCE BASE FEE R000.322.100.00.00 0.00 $32.50 PERMIT FEE R000.322.100.00.00 0.00 $765.20 PLAN CHECK FEE R000.322.102.00.00 0.00 $199.43 TECHNOLOGY FEE $39.89 TECHNOLOGY FEE R000.322.900.04.00 0.00 $39.89 PG16-0004 Address: 7300 FUN CENTER WAY Apn: 2423049063 $126.76 GAS $121.88 PERMIT ISSUANCE BASE FEE R000.322.100.00.00 0.00 $32.50 PERMIT FEE R000.322.100.00.00 0.00 $65.00 PLAN CHECK FEE 8000.322.103.00.00 0.00 $24.38 TECHNOLOGY FEE $4.88 TECHNOLOGY FEE iTOTAL FEES PAID , R:7401 R000.322.900.04.00 0.00 $4 88 I .61 Date Paid: Tuesday, January 19, 2016 Paid By: EVERGREEN REFRIGERATION LLC Pay Method: CHECK 007684 Printed: Tuesday, January 19, 2016 10:36 AM 1 of 1�� SYSTEMS 1 INSPECTION RECORDIM ���Oa� Retain a copy with permit INS P N N0. PERMIT N0. CITY OF' TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (2'�06) 4311- 6'10 Permit Inspection Request Line (206) 438-9350 Pro* ect: I, ♦. C -+P- Type of spection: "t ( Ad6 Date Called: Special Instructio DateW ted: �^ a.m. .. fb p.m. lRequeWer: Phone No: )inspector: I� (Date: �� s/'�(� REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. W - INSPECTION RECORD 05- Retain a copy with permit l 00 INS7ECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project: Type offf in pecti n: Address: Isp6eltia Date Called: Instructions: Date Wanted: a.m. s p.m. Requester: Phone No: u Inspector Date: �s V / REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. �— INSPECTION RECORD16 Retain a copy with permit IN. ON NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project: Type f Ins ction: r Address: 13 O® ruK Cf-,- -,- (k Dat Called: Special Instructions: Date Wanted: a.m. Z-- P.M. Requester: Phone No: Approved per applicable codes. EJ Corrections required prior to approval. Is ❑ REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit iNSPECTITN N0. PERMIT N0, CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project: _ (*-r Typf Inspection: Ito lk Address- 7300 C�-v- �a Date Cal Special Instructions: 1 Date Wanted: © / a.m. `''— � l ,l� p.m. Req ster: , Phone o: — 5 4— 7T Ilnspector: r �i (t�at�>— — �/ REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. 2012 Washington State Energy Code Compliance Forms for Commercial, Group R1, and > 3 story R2 and R3 mechanical Summary MEOH-SUM 2012 Washinqton State Enerqy Code Compliance Forms for Commercial, Group R1, and > 3 story R2 and R3 Revised June 2013 Project Info Project Address 7300 Fun Center Way Date 1/19/2016 Tukwila, WA 98188 For Building Dept. Use Applicant Name: Alex Burkhart Applicant Address: 727 South Kenyon St. Seattle, WA 98108 Applicant Phone: 206-763-1744 ext. 247 Project Description Briefly describe mechanical system type and features. Q Includes Plans i , i"la i`. `a4 ILA Installation of four (4) rooftop units and four (4) exhaust fans. JAN 19 2016 iL G CE GNiER ENTER Drawings must contain notes requiring compliance with commissioning provisions per Section 0408 Compliance Option Simple System O Complex System 0 Systems Analysis Equipment Schedules The following information is required to be incorporated with the mechanical equipment schedules on the plans. For projects without plans, fill in the required information below. Cooling Equipment Schedule Equip. ID Equip Type Brand Name' Model No.' Capacity2 Btu/h OSA CFM or Econo? SEER or EER IPLV3 Econmizer Option or Exception Heat Recovery Y/N RTU -1 Lennox KGA090S4B 92000 600 11 N/A Econmizer N RTU -2 Lennox KGA120S4M 118400 400 11 N/A Econmizer N RTU -3 Lennox KGA048S4D 50000 320 13 N/A Eoormizer N RTO -4 Lennox KGA060S4D 61800 400 13 N/A Eco=iZer N Heating Equipment Schedule Equip. ID Equip Type Brand Name' Model No.' Capacity2 Btu/h OSA cfm or Econo? Input Btuh Output Btuh Heat Efficiency° Recovery Y/N RTU -1 Lennox KGA090S4B 120000 600 150000 120000 80 N RTU -2 Lennox KGA120S4M 144000 400 188000 144000 80 N RTU -3 Lennox KGA048S4D 52000 320 65000 52000 80 N RTD -4 Lennox KGA060S4D 86000 400 108000 86000 80 N Fan E ui ment Schedule Equip. Equip ID Type Brand Name' Model No.' CFM SP' HP/BHP Flow Controls Location of Service EF -1 Broan L150 150 0.25 0.05 CV Ceiling EF -2 Broan L150 150 0.25 0.05 Cv Ceiling EF -3 Broan L150 150 0.25 0.05 CV c EF -4 Broan L100 93 0.25 0.05 CV Service Water Heating Equipment Schedule APPRawo Equip. ID Equip Type Brand Name' Input Model No.' Capacity Sub - Category EFSLF(rakn0fSe!JMC CRY Of Tukwila DIVISION ' If available. 2 As tested according to Table C403.2.3(1)A thru C403.2.3(8). 3 If required. ^ COP, HSPF, Combustion Efficiency, or AFUE, as applicable. 6 Flow control types: variable air volume (VAV), constant volume (CV), or variable speed (VS). 6 Economizer exception number per f4l v001 i 2012 Washington State Energy Code Compliance Forms for Commercial, Group R1, and > 3 story R2 and R3 Revised June 2013 Project Address 7300 Fun Center Way Date 1/19/2016 The following information is necessary to check a mechanical permit application for commercial provision compliance with the 2012 WSEC. NOTE: Define print area in Excel prior to printing MECH-CHK pages. Applicability Code Section Code Provision Information Required Location on Building Department (yes,no,na) Plans Notes GENERAL PROVISIONS Equipment Sizing & Performance Load calculations performed per ASHRAE Std 183 or equivalent per N/A C403.2.1 Load calculations Chat C403.2.2 Equipment and system Output capacity of heating and cooling equipment and systems do not M1 Yes sizing exceed calculated loads note exceptions taken Ventilation (natural or mechanical) provided per IMC; indicate mechanical Yes C403.2.5 Minimum ventilation ventilation is capable of being reduced to minimum requirement per IMC M1 C403.2.3 & Provide equipment schedules or complete MECH-SUM tables with type, C403.2.3.2 & Equipment minimum capacity, efficiency, test standard (or other efficiency source) for all Yes C403.2.12.1 efficiency mechanical equipment M1 N/A C403.2.13 Electric motor efficiency Provide equipment schedule with hp, rpm, efficiency for all motors; note except. Fan system motor hp or bhp does not exceed limits per Table N/A C403.2.10 Fan power limitation C403.2.10.1 1 C403.2.10.3 Indicate fan motors 1/12 to 1 hp are ECM type or meet minimum efficiency N/A & C403.2.13 Fractional hp fan motors reg. N/A C403.2.3 Maximum air cooled chiller Indicate air-cooled chiller capacity does not exceed air-cooled chiller limit capacity Non-standard water-cooled Full -load and NPLV values for water-cooled centrifugal chiller adjusted for N/A C403.2.1 chillers non-standard operational conditions Centrifugal fan cooling Large capacity cooling towers with centrifugal fan(s) meet efficiency N/A C403.2.12.1. towers requirements for axial fan open circuit cooling towers N/A C403.2.3 Forced air furnace and unit Indicate intermittent ignition or IID, flue/draft damper & jacket loss N/A C403.2.3.3 Packaged electric List equipment required to be heat pumps on schedule heating/coolinga ui ment N/A C403.2.3.4 Humidification Indicate method of humidification (note requirements for systems with economizer HVAC System Controls & Criteria Yes C403.2.4.1 Thermostatic controls Indicate locations of thermostatic control zones on plans, including M1 perimeter s stems C403.2.4.1.1 Heat pump supplementary Indicate staged heating (compression/supplemental) & outdoor lock -out Yes heat tem M 1 Yes C403.2.4.2 Setpoint overlap (deadband) Indicate 5°F deadband minimum for systems controlling both heating & M1 cooling C403.2.4.3 Automatic setback and Indicate zone t -stat controls with required automatic setback & manual M 1 Yes shutdown override Yes C403.2.4.3.3 Automatic (optimum) start Indicate system controls that adjust equip start time to match load M 1 conditions Yes C402.4.5.2 & Dampers Indicate location of OSA, exhaust, relief and return air dampers; include M1 C403.2.4.4 AMCA rated leakage and control t e motorized or ravit • note exceptions N/A C403.2.11 Heating outside a building Indicate radiant heat system and occupancy controls N/A C403.2.4.5 Snow melt systems Indicate shut-off controls based on outdoor conditions N/A C403.2.4.6 Combustion heating Indicate modulating or staged control equipment N/A C403.2.4.7 Group R1 hotel/motel Indicate method for guest room automatic setback & set-up of 5°F systems minimum N/A C403.2.4.8 / 9 Group R2/R3 dwelling unit Indicate 5-2 programmable thermostats in primary spaces with minimum of systems two setbackperiods; note exceptions taken N/A C403.2.5.1 Demand controlled Indicate high -occupancy spaces and systems requiring DCV ventilation N/A C403.2.5.2 Occupancy sensors Indicate spaces requiring occupancy -based system control and method; or alternate means provided to automatically reduce OSA when partially Enclosed loading Indicate enclosed loading dock and enclosed parking garage ventilation N/A C403.2.5.3 dock/parking garage system activation and control method ventilation N/A C403.2.5.4.1 Kitchen exhaust hoods Indicate kitchen hoods requiring make-up air; indicate make-up air source and conditioning method Indicate lab exhaust systems requiring heat recovery, method & efficiency; C403.2.5.4.2 Laboratory exhaust systems or alternative method taken (VAV, semi -conditioned makeup, or CERM N/A calculation C403.2.6.1 Energy recovery - Indicate ventilation systems requiring ER, method & efficiency; note N/A ventilation systems exceptions N/A C403.2.6.2 Energy recovery - Indicate on-site steam heating systems requiring energy recovery condensates stems N/A C403.2.6.3 Energy recovery - Indicate remote refrig. condensers requiring ER and use of captured energy condenser systerns State Energy Code Compliance Forms for Commercial, Group R1, and > 3 story Project Address 7300 Fun Center Way Date 1/19/2016 The following information is necessary to check a mechanical permit application for commercial provision compliance with the 2012 WSEC. NOTE: Define print area in Excel prior to printing MECH-CHK pages. Applicability Code Section I Code Provision I Information Required I Location Building Department (yes,no,na) I on Plans Notes GENERAL PROVISIONS, CONTINUED HVAC System Controls & Criteria, Continued Variable flow control - Indicate fan & pump motors requiring VF control & method (VSD or equiv N/A C403.2.12 fans/pumps controls N/A C403.2.12.1 Variable flow control - Indicate cooling tower fans requiring variable flow control and method cooling towers N/A C403.2.12.2 Large volume fan systems Indicate fan systems requiring airflow reduction based on heating and cooling demand; or exception taken Indicate method of cooling demand -based fan control for sys. > 110,000 C403.2.12.2 Single zone AC systems btuh N/A I N/A C403.2.4.10 1 DDC system capabilities Identify all DDC system input/output control points and indicate capability for trendina and Ducting Systems C403.2.7.1 & Duct construction Indicate all ductwork constructed and sealed per IMC, C402 leakage Yes C403.2.7.3 requirements and IBC vapor retarder requirements M 1 N/A 403.2.7.3.1- Duct pressure Identify location of low, medium and high pressure ductwork on plans classifications C403.2.7.3.3 High pressure duct leakage Indicate high pressure duct leakage testing requirements on plans; provide N/A test test results to jurisdiction when completed Yes C403.2.7.1 A Duct insulation Indicate R -value of insulation on ductwork M 1 Piping Systems N/A C403.2.8 Piping insulationIndicate R -value of insulation on piping N/A C403.2.8.1 Piping insulation exposed to Indicate method of protection from damage/degredation weather SIMPLE SYSTEMS Qualifying Systems C403.3 Qualifying single zone Verify unitary or packaged equipment does not exceed capacity limits, M Yes systems does not have active humidifcation or simultaneous heatin coolin 1 N/A C403.3 Qualifying 2 -pipe heating Verify 2 -pipe heating -only system does not exceed capacity limits systems N/A C403.3.2 Hydronic system controls Refer to Complex Systems Section C403.4.3 Simple System Economizers Yes C403.3.1 Air economizer required Indicate cooling systems requiring economizer controls; note in equip M 1 sched. Yes C403.3.1.1.1 Air economizer capacity Indicate modulating OSA control capability up to 100% OSA, or exception M 1 Yes C403.3.1.1.3 Air economizer high limit Indicate high limit shut-off control method per Table C403.3.1.1.3(2) M 1 controls Yes C403.1.1.2 Integrated air economizer Indicate capability for partial air economizer operation for systems with M 1 operation capacity > 65,000 btuh Yes C403.3.1 Air economizer exceptions Indicate eligible exception(s) taken and provisions to comply with M1 COMPLEX SYSTEMS Complex System Economizers Yes C403.4.1 Air economizer required Indicate cooling systems requiring economizer controls; note in equip M1 sched. C403.4.1.4 Economizer heating system Verify control method of HVAC systems with economizers does not Yes impact increase building heating energy usage during normal operation M1 Yes C403.4.1.3 Integrated economizer Indicate capability for partial economizer operation for air or water econo M1 operation systems Moved Water economizer capacity Indicate water econo capable of 100% cooling capacity at 50°F db/45°F wb N/A OSA C403.4.1.2 Water economizer Indicate precooling coils and heat exchangers do not exceed pressure N/A maximum pressure drop drop limit N/A C403.3.1 Air economizer exceptions Indicate eligible exception(s) taken and provisions to comply with Mechanical Permit ..•- 3 of 2012 Washington State Energy Code Compliance Forms for Commercial, Group R1, and > 3 story R2 and R3 Revised ,lune 2013 Project Address 7300 Fun Center Way Date 1/19/2016 The following information is necessary to check a mechanical permit application for commercial provision compliance with the 2012 WSEC. NOTE: Define print area in Excel prior to printing MECH-CHK pages. Applicability Code Section Code Provision Information Required Location on Building Department (yes,no,na) Plans Notes COMPLEX SYSTEMS, CONTINUED Specific System Requirements N/A 0403.4.2 & Variable flow control - fans Indicate fans requiring variable flow control and method 0403.2.12 VAV fan static pressure Indicate sensor locations on plans; include at least one sensor per major N/A 0403.4.2.1 sensors duct branch 0403.4.2.2 VAV fan static pressure Indicate fan system static pressure setpoint based on zone requiring most N/A setpoint pressure VAV systems serving multi- Indicate supply air systems serving multiple zones that are required to be C403.4.5 VAV, method of primary air control, and zones served; note exceptions N/A zones taken N/AC403.4.5.4 / VAV system supply air reset Indicate controls that automatically reset supply air temp in response to loads N/A 0403.4 Large capacity cooling Indicate method of multi-stage or variable control for building cooling s stems system capacity > 300 tons N/A C403.4.7 Hot gas bypass limitation Indicate cooling equipment unloading or capacity modulation method N/A 0403.4.3 Large capacity boiler Indicate multi-stage or modulating bumer for single boilers > 500,000 btuh s stems N/A C403.4.3 Boiler sequencing Indicate automatic controls that sequence operation of multiple boilers 0403.4.3.5 Chiller / boiler plant pump Indicate capability to automatically reduce overall plant flow and shut-off N/A isolation flow through chillers & boilers when not in use C403.4.2 & Variable flow control - Indicate pumps requiring variable flow control & method N/A C403.4.3.6 pumps N/A 0403.2.12.1 Variable flow control - Indicate cooling tower fans requiring variable flow control and method & C403.4.4 coolin towers N/A C403.4.3.4 Hydronic system part load Indicate heating & chilled water systems have the capability to automatically controls reset supply water temp AND reduce flow b >_ 50% fors stems>300,000 N/A C403.4.3.2 Two-pipe changeover Indicate deadband, heating/cooling mode scheduling and changeover systems temperature range 0403.4.3.3.1 Water loop heat pump - Indicate capability of central equipment to provide min. 20°F water supply N/A deadband temp deadband between heat re'ection and heat addition modes 0403.4.3.3 Water loop heat pump - Provide heat exchanger that separates cooling tower and heat pump loop N/A heat re'ection in Climate Zone 5 N/A 0403.4.3.3.3 Water loop heat pump - Indicate 2-way isolation valve on each heat pump and variable flow control isolation fors stems with total pump power > 10 h N/A C403.4.6 Condenser water heat Indicate system provided to pre-heat service water and efficiency recovery N/A 0403.5 Cooler / freezer - anti-sweat Indicate w/sf & control method for walk-in coolertfreezer door anti-sweat heaters heaters N/A C403.5 / 6 Cooler / freezer - evaporator Indicate motor type for evaporator and condenser fans < 1 hp SERVICE WATER HEATING Service Water Systems N/A C404.2 Water-heating equip min. Provide equipment schedule or complete MECH-SUM table with type, efficient capacity, efficiency, test standard or other efficient source N/A C404.3 Temperature controls Indicate temperature controls have required setpoint capability N/AC404.4 / Heat traps Indicate piping connected to equipment have heat traps on supply & discharge N/A 0404.5 Insulation under water Indicate R-10 insulation under tank heater N/A C404.6 Service water piping Indicate R-value of insulation on piping; note exceptions taken insulation C404.7 / 6 Circulation systems and Indicate shut-off capability based on occupancy and periods of limited N/A heat trace shut-off demand N/A C404.9 Group R-2 service hot water meters Indicate method of usage metering for dwell. units served by central HW isystem Pools & In-Ground Permanently Installed Spas Pool heating equip min. Provide equipment schedule or complete MECH-SUM table with type, N/Aefficiency C404.1 0.1 capacity, efficiency, test standard (or other eff. source); heat pump heaters > 4 COP N/A C404.10.1 / 2 Pool heater on / off controls Indicate automatic on/off control based on scheduling & accessible on/off switch on heater that operates independent of thermostat settin • or N/A C404.10.3 Pool covers Indicate vapor retardant cover and insulation rating as required N/A C404.10.3 Pool assembly insulation Indicate rating of insulation on sides and bottom of pools heated to > 90°F N/A C404.10.4 Heat recovery Indicate method, exhaust air temperature reduction and recovered energy PERMIT COORD COPY PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: M16-0011 DATE: 01/20/16 PROJECT NAME: FAMILY FUN CENTER SITE ADDRESS: 7300 FUN CENTER WAY X I Original Plan Submittal Revision # before Permit Issued Response to Correction Letter # Revision # after Permit Issued DEPARTMENTS: pw A*& 41-� Building Division .f' ; Public Works ❑ PRELIMINARY REVIEW: Not Applicable ❑ (no approval/review required) REVIEWER'S INITIALS: APPROVALS OR CORRECTIONS: Approved ❑ Corrections Required ❑ (corrections entered in Reviews) Notation: REVIEWER'S INITIALS: MA Aft till Fire Prevention Structural ❑ Planning Division ❑ Permit Coordinator ❑ DATE: 01/21/16 Structural Review Required ❑ DATE: DUE DATE: 02/18/16 Approved with Conditions ❑ Denied ❑ (ie: Zoning Issues) DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: 12/18/2013 EVERGREEN REFRIGERATION T.LC Page 1 of 3 Hoene Espanol Contact Search L&I � q J A-1 Index Help My Secure L &I Safety & Health Claims & Insurance Workplace Rights Trades & Licensing Washington State Department of Labor & Industries EVERGREEN REFRIGERATION LLC Owner or tradesperson Principals PATTON, RODGER, PARTNER/MEMBER PATTON, MATTHEW, PARTNER/MEMBER Patton, Adam, PARTNER/MEMBER Patton, Douglas, PARTNER/MEMBER EVERGREEN REFRIGERATION LLC, PARTNER/MEMBER PATTON, DAVID, PARTNER/MEMBER (End: 01/21/2014) Doing business as EVERGREEN REFRIGERATION LLC 727 S KENYON ST SEATTLE, WA 98108 206-763-1744 KING County WA UBI No. Business type 602 512 953 Limited Liability Company Governing persons DAVID A PATTON MATTHEW PATTON; RODGER PATTON; License Verify the contractor's active registration / license / certification (depending on trade) and any past violations. Construction Contractor Active. ........................................................................... Meets current requirements. License specialties GENERAL License no. EVERGRL954R2 Effective — expiration 01/06/2006— 01/06/2018 Bond ................ Merchants Bonding Co (Mutual) $12,000.00 Bond account no. WA15097 Received by L&I Effective date 12/15/2011 01/01/2012 Expiration date Until Canceled Bond history Insurance ............................... Nationwide Mutual Ins Co $1,000,000.00 Policy no.V.3 ACP 3007246151 https:Hsecure.Ini.wa.gov/verify/Detail.aspx?UBI=602512953&LIC=EVERGRL954R2&SAW= 02/17/2016 FILE COPY Permit No. Plan review approval is subject to errors and omissions. Approval of construction documents does not authorize the violation of any adopted code or ordinance. Receipt of approved Field Copy and conditions is acknowledged: By: Date: 1 City of Tukwila BUILDING DIVISION SITE LOCATION SCALE: NONE AIR TERMINAL UNIT SCHEDULE MODEL MATERIAL MOUNTING FINISH SIZE REMARKS PHASE DUCT THICKNESS R -VALUES SECTION HVAC controls have been tested to ens re that control devices are calibrated, adjusted and operate proper�y. Sequence of ope�^ation have been functionally tested to ensure they OPOL do acc r once w h approved44 WEIGHT TOTAL FILTER SIZES EXPOSED SUPPLY -INSIDE BUILDING ENVELOPE SIDE WALL DIFFUSER SWD-1 TITUS 30ORS STEEL SURFACE WHITE SEE DRAWINGS BORDER TYPE 1 SIDE WALL GRILLE SWG-1 TITUS 350RL STEEL SURFACE WHITE SEE DRAWINGS BORDER TYPE 1 EXPOSED SIDE WALL DIFFUSER SWD-2 TITUS 30OFS ALUMINUM DUCT MOUNTED WHITE SEE DRAWINGS ASD DAMPER EXTRACTOR SUPPLY DIFFUSER SIZE SIZE RANGE 8" X 6" 200 CFM AND BELOW 10" X 8" ABOVE 200 CFM COMMISSIONOING PLAN ALL COMMISSIONING OF HEATING, VENTILATI❑N AND AIR CONDITIONING SYSTEMS AS REQUIRED BY SECTION C408 "SYSTEM COMMISSIONING" OF THE 2012 WASHINGTON STATE ENERGY CODE (WSEC) SHALL BE PERFORMED BY EVERGREEN REFRIGERATION, LLC, THE ACTIVITIES TO BE ACCOMPLISHED ARE PER THE SECTIONS LISTED IN THE "COMMISSIONING COMPLIANCE CHECKLIST" SHOWN BELOW, AT THE COMPLETION OF THE ACTIVITIES REQUIRED FOR COMMISSIONING AS DEFINED BY SECTION C408 OF WSEC THE 'COMMISSIONING COMPLIANCE CHECKLIST' WILL BE REVIEWED WITH THE BUILDING OWNER OR THE OWNER'S REPRESENTATIVE AND THIS CERTIFICATION WILL BE SIGNED AND DATED, THIS WILL SATISFY TO THE CODE OFFICIAL THAT THE REPORT HAS BEEN ACCEPTED AS REQUIRED BY SECTION C40812,1 OF WSEC, COMMISSIONING COMPLIANCE CHECKLIST Project Name: Project Information Project Address: Commissioning Authority: Commissioning Plan (Section C408.L1) Systems Balancing (Section C408.2.2) ams an secIVI DUCT INSULATION TABLE MANF. MODEL ❑ HVAC Equipment Functional Testing has been completed (Section C4082.3.1) WSEC REQUIRED INSULATION WSEC 2012 PHASE DUCT THICKNESS R -VALUES SECTION HVAC controls have been tested to ens re that control devices are calibrated, adjusted and operate proper�y. Sequence of ope�^ation have been functionally tested to ensure they OPOL do acc r once w h approved44 WEIGHT TOTAL FILTER SIZES EXPOSED SUPPLY -INSIDE BUILDING ENVELOPE NONE NONE C403.2.7.2 EF 1 SQ/RECT SUPPLY -INSIDE BUILDING ENVELOPE L150 R-3.3 C403.2.7.2 115 1 1.4 A LOCATED ON CEILING EF 2 IW- ROUND SUPPLY -INSIDE BUILDING ENVELOPE 1.5" R-3.3 C403.2.7.2 1 1.4 A LOCATED ON CEILING EF 3 BROAN L150 SUPPLY/RETURN/OSA-OUTSIDE BUILDING ENVELOPE 2" R-8.0 C403.2.7.2 1.4 A RETURN -INSIDE BUILDING ENVELOPE NONE NONE C403.2.7.2 ex 2 w z RELIEF NONE REQUIRED Ui LU EXHAUST NONE REQUIRED SUPPLY DIFFUSER SIZE SIZE RANGE 8" X 6" 200 CFM AND BELOW 10" X 8" ABOVE 200 CFM COMMISSIONOING PLAN ALL COMMISSIONING OF HEATING, VENTILATI❑N AND AIR CONDITIONING SYSTEMS AS REQUIRED BY SECTION C408 "SYSTEM COMMISSIONING" OF THE 2012 WASHINGTON STATE ENERGY CODE (WSEC) SHALL BE PERFORMED BY EVERGREEN REFRIGERATION, LLC, THE ACTIVITIES TO BE ACCOMPLISHED ARE PER THE SECTIONS LISTED IN THE "COMMISSIONING COMPLIANCE CHECKLIST" SHOWN BELOW, AT THE COMPLETION OF THE ACTIVITIES REQUIRED FOR COMMISSIONING AS DEFINED BY SECTION C408 OF WSEC THE 'COMMISSIONING COMPLIANCE CHECKLIST' WILL BE REVIEWED WITH THE BUILDING OWNER OR THE OWNER'S REPRESENTATIVE AND THIS CERTIFICATION WILL BE SIGNED AND DATED, THIS WILL SATISFY TO THE CODE OFFICIAL THAT THE REPORT HAS BEEN ACCEPTED AS REQUIRED BY SECTION C40812,1 OF WSEC, COMMISSIONING COMPLIANCE CHECKLIST Project Name: Project Information Project Address: Commissioning Authority: Commissioning Plan (Section C408.L1) Systems Balancing (Section C408.2.2) ams an secIVI MARK MANF. MODEL ❑ HVAC Equipment Functional Testing has been completed (Section C4082.3.1) Functional Testing HVAC equipment has been tested to demonstrate the installation and operation of components, systems and system -by -system Interfacing relationships In accordance with approved plans and specifications PHASE ❑ HVAC Controls Functional Testing has been completed (Section C408.2.3.2) NOTES COOLING (Sections C408.2.3) HVAC controls have been tested to ens re that control devices are calibrated, adjusted and operate proper�y. Sequence of ope�^ation have been functionally tested to ensure they OPOL do acc r once w h approved44 WEIGHT TOTAL ca ons ❑ Economizers Functional Testing has been completed (Section C408.2.3.3) Economizers operate In accordance with Manufacturer's specifications Supporting ❑ Documents Manuals, record documents and training have been completed or are scheduled (Section • System documentation has been provided to the owner or scheduled C408.1,32) • Record documents have been submitted to owner or scheduled date: _---------------- -_ -- • Training has been completed or scheduled Commissioning Report ❑ Preliminary Commissioning Report submitted to Owner and Includes Items below (Section • Deficiencies found during testing required by this section which have not been corrected at the time of C40812) report preparation • Deferred tests, which cannot be performed at the time of report preperation due to climatic conditions. Certification I hereby certify that all requirements for Commissioning have been completed in accordance with the Washington State Energy Code, Including all Items above. Building Owner or Owner's Representative Date EXHAUST FAN SCHEDULE MARK MANF. MODEL CFM S.P. VOLTS PHASE Hp/A NOTES COOLING HEATING ELECTRICAL WEIGHT TOTAL FILTER SIZES NOTES CFM WC CFM EF 1 BROAN L150 150 0.25" 115 1 1.4 A LOCATED ON CEILING EF 2 BROAN L150 150 0.25" 115 1 1.4 A LOCATED ON CEILING EF 3 BROAN L150 150 0.25" 115 1 1.4 A LOCATED ON CEILING EF 4 BROAN L100 93 0.25" 115 1 1.1 A LOCATED ON CEILING NOTE: INTERLOCK W/ LIGHTSWITCH BY ELECTRICAL CONTRACTOR GAS PACKAGE EQUIPMENT SCHEDULE MARK MANF. MODEL TONS. AIRFLOW SP MIN. OSA Motor DRIVE COOLING HEATING ELECTRICAL WEIGHT TOTAL FILTER SIZES NOTES CFM WC CFM Hp STYLE TOTAL SEER EER INPUT OUTPUT AFUE VOLTS PHASE M.C.A. SMOKE DETECTOR T� T THERMOSTAT QS S SENSOR -R- - - -R R REFRIGERANT LINES -G- - - -G G NATURAL GAS LINES BTUH CEILING DIFFUSER (SUPPLY) ® BTUH BTUH M (V) INLINE FAN (A) LBS NO. (LxWxD) SIDEWALL DIFFUSER do RTU 1 LENNOX KGA090S4B 7.5 3000 0.5 600 2.00 BD 92,000 -- 11.0 150,000 120,000 80% 230 30 42.0 1004 4 (20" x 20" x 2") 1,2 RTU 2 LENNOX KGA120S4M 10 4000 0.5 400 3.00 BD 118,400 --- 11.0 188,000 144,000 80% 230 -30 46.0 1158 4 (20" x 24" x 2") 1,2 RTU 3 LENNOX KGA048S4D ' 4 1600 0.5 320 0.5 DD 50,000 13.0 11.0 65,000 52,000 80% 230 30 23.0 772 4 (16" x 20" x 2") 1 RTU 4 LENNOX KGA060S4D 5 2000 0.5 400 0.75 DD 61,800 13.0 11.2 108,000 86,000 80% 230 30 25.0 810 4 (16" x 20" x 2") 1 NOTES: 1. THE ROOFTOP UNIT COMES COMPLETE WITH AN ECONOMIZER 2. THE ROOFTOP UNIT COMES COMPLETE WITH A SMOKE DETECTOR IN THE MAIN RETURN DUCT GENERAL NOTES DUCTWORK 1.1 ALL DUCT DIMENSIONS ON PLAN ARE CLEAR INSIDE DIMENSIONS, ADD 2" TO EACH DIMENSION TO OBTAIN OUTSIDE DIMENSION. ADD 470 EACH DIMENSION IF DUCTWORK IS ON THE EXTERIOR OF BUILDING. 1.2 THE FIRST NUMBER ON ALL DUCT DIMENSIONS IS THE WIDTH AND THE SECOND NUMBER IS THE HEIGHT. 1.3 MATERIALS WITHIN DUCTS OR PLENUMS SHALL HAVE A FLAME SPREAD RATING LESS THAN 25 AND A FLAME SMOKE DEVELOPMENT RATING LESS THAN 50, PER IMC 602.2.1. 1.4 SEAL ALL TRANSVERSE JOINTS FOR DUCTWORK WITH STATIC PRESSURE BETWEEN 1/2 INCHES AND 2 INCHES. DUCTWORK WHICH IS DESIGNED TO OPERATE AT PRESSURES ABOVE 1/2 INCH WATER COLUMN STATIC PRESSURE SHALL BE SEALED IN ACCORDANCE WITH STANDARD RS -7. 1.5 ALL DUCT GAUGES PER SMACNA, IMC 603-4. 1.6 ALL DUCT SUPPORTS PER SMACNA, IMC 603-10. 1.7 ATTACH DIFFUSERS AND GRILLES TO T -BAR GRID PER WA STATE & LOCAL CODES. 1.8 BALANCING DAMPERS ARE TO BE INSTALLED ON ALL BRANCH DUCTS OR DIFFUSERS. INSULATION 2.1 INSULATE OR LINE DUCTWORK PER WA. STATE ENERGY AND MECHANICAL CODES. 2.2. INSULATE REFRIGERANT & CONDENSATE PIPING PER STATE & LOCAL ENERGY CODES. GENERAL CONTRACTOR 3.1 GENERAL CONTRACTOR TO PROVIDE AND CUT OPENINGS FOR ALL ROOFTOP, CEILING, FLOOR, AND WALL PENETRATIONS, INCLUDING WEATHERPROOF SEALING AND FIRE PROOF LINING PER IMC & IBC. 3.2 GENERAL CONTRACTOR TO VERIFY PENETRATION LOCATION AND DIMENSIONS. WITH ERL BEFORE FRAMING OPENINGS. 3.3 GENERAL CONTRACTOR TO PROVIDE ALL DEMOLITION, PATCHING, AND PAINTING AS REQUIRED FOR MECHANICAL WORK. 3.4 GENERAL CONTRACTOR TO PROVIDE ADEQUATE STRUCTURAL SUPPORT AS REQUIRED FOR MECHANICAL WORK. 3.5 GENERAL CONTRACTOR TO PROVIDE ADEQUATE ENGINEERING AS REQUIRED FOR MECHANICAL WORK. 3.6 GENERAL CONTRACTOR TO PROVIDE SERVICE ACCESS PER CODE TO ALL MECHANICAL EQUIPMENT. 3.7 GENERAL CONTRACTOR TO LEVEL ALL FACTORY CURBS PROVIDED BY ERL PROVIDE ALL CANT STRIPS AND CURB INSULATION, AND SEAL AGAINST LEAKS. 3.8 GENERAL CONTRACTOR TO PROVIDE ALL CUTTING AND PATCHING OF T -BAR CEILING AS REQUIRED FOR HVAC INSTALLATION. 3.9 GENERAL CONTRACTOR TO PROTECT ALL OPENINGS THROUGH FLOORS PROVIDED FOR DUCTWORK INSTALLATION IN ACCORDANCE WITH TABLE 601 OF INTERNATIONAL BUILDING CODE, WHERE REQUIRED BY SECTION 707 OF IBC. ELECTRICAL 4.1 ERL TO INSTALL ALL LOW VOLTAGE CONTROL WIRING, CONDUIT WILL BE PROVIDED BY ELECTRICAL CONTRACTOR. 4.2 ELECTRICAL CONTRACTOR TO PROVIDE ALL ELECTRICAL CONNECTIONS, DISCONNECTS, AND STARTERS FOR MECHANICAL EQUIPMENT. 4.3 ELECTRICAL CONTRACTOR TO VERIFY EQUIPMENT SIZES, LOADS AND LOCATIONS WITH ERL MECHANICAL PLAN AND WITH FIELD CONDITIONS. 4.4 ELECTRICAL CONTRACTOR TO INTERLOCK BATHROOM EXHAUST FANS WITH LIGHT SWITCH. 4.5 ERL TO PROVIDE 7 -DAY NIGHT SETBACK, PROGRAMMABLE TYPE T -STAT WITH CAPABILITY OF 5°F DEADBAND. 4.6 ERL TO VERIFY FINAL LOCATION OF THERMOSTAT WITH CUSTOMER. 4.7 ELECTRICAL CONTRACTOR TO PROVIDE ELECTRICAL GCFI OUTLET WITHIN 25 FT OF EACH PIECE OF MECHANICAL EQUIPMENT. PLUMBING 5.1 PLUMBING CONTRACTOR TO FURNISH AND INSTALL ALL GAS PIPING FOR MECHANICAL EQUIPMENT PER CODE. 5.2 PLUMBING CONTRACTOR OFFSET VENTS 10 FEET MINIMUM FROM ALL HVAC FRESH AIR INTAKES OR 2' ABOVE HIGHEST POINT OF INTAKE, IMC 401.4.1. 5.3 CONDENSATE DRAINS FROM RTU BY ERI TO DRAIN WITHIN 12" OF UNIT. CONDENSATE DRAINS FOR AIR HANDLERS BY PLUMBER. ENERGY CODE COMPLIANCE 6.1 THE SUPPLY HEATING AND COOLING ENERGY TO EACH ZONE SHALL BE CONTROLLED BY INDIVIDUAL THERMOSTATIC CONTROLS CAPABLE OF RESPONDING TO TEMPERATURE WITHIN THE ZONE. AT A MINIMUM, EACH FLOOR SHALL BE CONSIDERED AS A SEPARATE -ZONE 6.2 OUTDOOR AIR SUPPLY, EXHAUST OPENINGS AND RELIEF OUTLETS FOR EQUIPMENT GREATER THAN 300 CFM SHALL BE PROVIDED WITH CLASS 1A MOTORIZED DAMPERS WHICH CLOSE AUTOMATICALLY WHEN THE SYSTEM IS OFF PER WSEC/SEC SECTION C402.4.5.2. MECHANICAL CODE COMPLIANCE 7.1 WHERE REQUIRED PROVIDE AUTOMATIC SHUTOFF ACTIVATED BY SMOKE DETECTORS IN EACH SYSTEM DELIVERING HEATING OR COOLING AIR IN EXCESS OF 2000 CFM. DETECTORS SHALL BE LOCATED IN THE MAIN RETURN AIR PER IMC 606. WA2012 NOT PUBLISHED. ALL RIGHTS RESERVED. THE DRAWING AND SPECIFICATIONS, IDEAS, DESIGNS AND ARRANGEMENTS REPRESENTED THEREBY ARE AND SHALL REMAIN THE PROPERTY OF EVE- RGREEN REFRIGERATION INC. NO PART THEREOF SHALL BE REPRODUCED, COPIED, ADAPTED, DISC- LOSED OR DISTRIBUTED TO OTHERS, SOLD, PUB- LISHED OR OTHERWISE USED WITHOUT THE PRIOR WRITTEN CONSENT OF AND APPROPRIATE COMPEN- SATION TO EVERGREEN REFRIGERATION INC. VISUAL CONTACT WITH THE ABOVE DRAWINGS OR SPECIFIC- ATIONS SHALL CONSTITUTE CONCLUSIVE EVIDENCE OF ACCEPTANCE OF THESE RESTRICTIONS. 2 L0 C Op N w Wco w r r. O N i'N Z O F= 0 F - Z afaf d' W :2 C/)0 F iL Z Z i 00. Q C0 ry 0 O J_ 0 0 Z W N w (ten 0 0 Q ❑ ❑ _O 00 z z Z 0 0 LI 0 Q J ry W DO UJIW 0T0 Z U) Ill- 0) U or_ W Q Z W U3: Z)0 zQ LI_ (.) � J_ LL U S o Q o LJ_ _ I.-- �- ? REVISIONS p NO DATE ITEM N :VVED FOR CODE COMPLIANCE FEBI 0 5 2016 LOO -� City of Tuwla R� BUILDING DIVISION W JAN 19 2016 PERMIT CENT ER DWG. BY: GN C H K. BY: MG JS JOB NO.: 515244 SHEET: SYMBOL LEGEND SYMBOL ABBY. DESCRIPTION ® DUCT SECTION SUPPLY ® DUCT SECTION - RETURN/EXHAUST 1 x RECTANGULAR DUCT r lie ROUND DUCT FLEXIBLE DUCT MVD MANUAL VOLUME DAMPER BDD BDD BACKDRAFT DAMPER MD MOTORIZED DAMPER FD FIRE DAMPER ® FSD FIRE/SMOKE DAMPER (120V POWER REQ.) -®-� CEILING RADIATION DAMPER sn SD SMOKE DETECTOR T� T THERMOSTAT QS S SENSOR -R- - - -R R REFRIGERANT LINES -G- - - -G G NATURAL GAS LINES ® CEILING DIFFUSER (SUPPLY) ® CEILING DIFFUSER (RETURN/EXHAUST) EXHAUST FAN (CEILING MOUNTED) INLINE FAN ® PROPELLER FAN SIDEWALL DIFFUSER do Oft AM T FiffING NOT PUBLISHED. ALL RIGHTS RESERVED. THE DRAWING AND SPECIFICATIONS, IDEAS, DESIGNS AND ARRANGEMENTS REPRESENTED THEREBY ARE AND SHALL REMAIN THE PROPERTY OF EVE- RGREEN REFRIGERATION INC. NO PART THEREOF SHALL BE REPRODUCED, COPIED, ADAPTED, DISC- LOSED OR DISTRIBUTED TO OTHERS, SOLD, PUB- LISHED OR OTHERWISE USED WITHOUT THE PRIOR WRITTEN CONSENT OF AND APPROPRIATE COMPEN- SATION TO EVERGREEN REFRIGERATION INC. VISUAL CONTACT WITH THE ABOVE DRAWINGS OR SPECIFIC- ATIONS SHALL CONSTITUTE CONCLUSIVE EVIDENCE OF ACCEPTANCE OF THESE RESTRICTIONS. 2 L0 C Op N w Wco w r r. O N i'N Z O F= 0 F - Z afaf d' W :2 C/)0 F iL Z Z i 00. Q C0 ry 0 O J_ 0 0 Z W N w (ten 0 0 Q ❑ ❑ _O 00 z z Z 0 0 LI 0 Q J ry W DO UJIW 0T0 Z U) Ill- 0) U or_ W Q Z W U3: Z)0 zQ LI_ (.) � J_ LL U S o Q o LJ_ _ I.-- �- ? REVISIONS p NO DATE ITEM N :VVED FOR CODE COMPLIANCE FEBI 0 5 2016 LOO -� City of Tuwla R� BUILDING DIVISION W JAN 19 2016 PERMIT CENT ER DWG. BY: GN C H K. BY: MG JS JOB NO.: 515244 SHEET: NOT PUBLISHED. ALL RIGHTS RESERVED. THE DRAWING AND SPECIFICATIONS, IDEAS. DESIGNS AND ARRANGEMENTS REPRESENTED THEREBY - ARE AND SHALL REMAIN THE PROPERTY OF EVE- RGREEN REFRIGERATION INC. NO PART THEREOF SHALL BE REPRODUCED, COPIED. ADAPTED, DISC- LOSED OR DISTRIBUTED TO OTHERS, SOLD, PUB- LISHED OR OTHERWISE USED WITHOUT THE PRIOR WRITTEN CONSENT OF AND APPROPRIATE COMPEN- SATION TO EVERGREEN REFRIGERATION INC. VISUAL CONTACT WITH THE ABOVE DRAWINGS OR SPECIFIC- ATIONS SHALL CONSTITUTE CONCLUSIVE EVIDENCE OF ACCEPTANCE OF THESE RESTRICTIONS. LO _ W M W W Ld 0 0 0 M l r_ 35'-6" 24 -7 1 /2 24 -7 1 /2 » » 6 35 -6 1'-6" Cfl lo loN LL WALL CAP i WALL CAP co s 3 8" N Z — --— -_JL----JL---J—L-JL- L_-__J 1---�---- j J ---.JL---JL-- EF , 0 s ; s 6� .r s s may. F— LLj --_---- -- ---- - _ _ -----. --- -- - - .. _-- ... - --- -__- - - _ - -- - [ __ z Z O w CJ Q UP TO RTU - --� 1i -3 - ---- --- -i I > 0 r ; 3/4 {; f O FULL SIZE —. �+- !- 500 CF f , ; �„ J OF UNIT PAN TAPPING 10" UP _ �G, �• RT _�f _._ __ r { TYP 8 : ; s :: ' ! s CO Z . 1 s ; ) j {; ,d 0 0 W m SCREENED OPENING EF i ,\ SWD-1 j ! t I 12 — - - - - _ - -- - --- ----- - ----- ------ ---- -- ---------- - --- - ---- -__.! __ _ N w it j N G TON � � f . , ` i. : 1 2 F I i ; I _._-__.�_ :___._ _. �____._._._ ___..._ _ _----- -:_ _.:. _._.__--____ __.:._------------_-_-_-----------__.�_______.________.___ �si__—_._-_.� _ __' I Q _ U ON ROOF ; �; s ; ! 1 150 CFH '� r , IM ❑ ❑ 16" - _ - 450 CFM.- EF ; I 2 - - -. I ` T� — — — ,I - - —A h 1 SEE ACOUSTIC OOT DETAIL.. s_ , TYP - ( ) ACO SOOT EAI A 3,4 L ^I— SCALE: N.T.S. , �IV12) -------------- - I - z N _ O RT { i i, 4 Q / n n li f_ - 10 TON ,; 20 I . �- ! � Q _. OF ON RO 00 -- - - — -- — — — — _ �—; ---�-- --.. 2 — — — _ — _ .. _ — J 18 _ ui - — - / ; { -_— T � 0 / 00 Z 400 CFM i, �___. _ _.._._.__ W z � TYP 4 +'I- _ --- - _._. _ - --- ...__ ----I ---- ...._ -- - -' w_ �_--- -^—_- I C( Lu tilml Ir f t 111 ■ I G (- 3 ILL 4 TON {-- _ p o ON ROOF------------=�--�=.�.=�_ -.i=�__.—,-------. �=.__._-� �--_-_ .___.__,.��.------ _� v______ \Q � 6 FH _ ----1411 14 T n L i s r I tt , F r Ift- II- ry �r_ i REVISIONS 4 ? - ------ _ - _--------- ! C 5 ON ;; ,� '-----___..------------- _ ._---- --• --------- -_ - - _-------..�___-_ .._. _ _. . __ _ _.__._---s---_-__ � NO DATE ITEM R U4 ON ROOF (- 1091CFH____---500 CFM I I I I—_._.-------------___�____-- ---------__.___.I.__—___-__-.-------_-_ ___..__.___ _ .________ �' ! r; , { � 112" —— — N - _ - _ J - --- - ---- - - _ _ _- - - - --- -- - -- - - - - - - - - - ---- _ - -- _ ._- -----_____ _.- . _-__ -___ _ — _ __ r — _ _--_-.�. _.__.__-.- , R VYE FOR - - - --- i - - , ,;I � w E lr-' U it - I -. LO co City of Tukwila �- � BUILDING RIVIStON LJi , isf%i4'J ,1y W JAN 1 9 2016 DWG. BY: GN CHK. BY: MG JS JOB NO.: 515244 SHEET: M 2 aeconaary rartz,,cneauie Secondary Bracing Schedule Mark Part Thick. Depth Lap Detail Id Qty Mark No Spacing E199 OIIIOES2200411830 0.1130 10" RS12PH, RS12PA, RS12PJ 1 20 CPSRA010602 1'-1. 3/8" E107 00310ES241141IB30 0.1130 10" RS12PA, RS12PJ 2 236 CPB8040108(Typ.) E173 0051OBS2200414930 0.0790 1'b" BRO9W2 3 18 CF88021106 2'-9 13/16" )0167 00610ES2411914834 0.0790 10" BR09W2; RS12PE, RS12PJ 4 42 PSA0102 3 13/16" E195 00110ES2411411B30 0.1130 10" R512PH, RS12PA, RS12PJ 5 $ PBA0108 1'-4 1/2" E82 00210E$2411414B30 0.0790 10" BR09W2 6 8 PBA0105 1'-1 1/2" I E174 008101S2411411B30 0.1130 10" RS12PA, RS12PJ 4c? 7 4 PBA0305 3'-1 5/8"009IOES2411414B30 0.0790 10"BR09W28 18 CPBB41fl508 1'-4" E200 01210ES2200414830 0.0790 lo"BR09W2 5 4 3 2 a See SED: # E203 01010ES2103214B30 0.0790 10" BR09W2 BR09PK, BR09RY, BR09RZ, BR09PH, BR09Jii B197 00710ES220461IB30 0,1130 30 RS12PA, RS12PJ 117'-5 3/4 BR09JG, BR09K5, BR09K2, BR18G2, BR09JR P747 01010ZS341141682 0.06$0 10" : 2'-•10 1/2" R501U1 � Q�-- 16�-4" 25•-0" 2s1-a" zs•-o 2z-r" .-^•..^-...»�•�»� 4� P709 03010ZS2400415B3 0.0730 14" 1'-10 1/2" RS02TI, RSOIUl BR09Jtt y�e 2R2B5 .� 2R2B5 2R2B4 2R2B3 2R2BZ 2R2B1 P289 00710ZS3011414B2 0.0790 10" 2 T-10 1/2" R501u1 .........�..... .. �. �.....«...... 7(rl_......, ».... .. .... .. «...... »�..... .. «.........» .. .« .� .�...�...,» .. _ _ _ .. .... '�F 9203{Flip) 167{i11p1 "167{plip) •;-•�•-- ��z:67(mipl +* L'173tFIip1 _ P410 01310ZS261141732 0.0600 14'T 1'-4 1/2" RS01TD, RSOZUI E1s7 1187 x.87 197 la7 P708 0161flZS30II412B2 0.4980 10" 2'-•10 1l2" RS01u1 r 706 a 70 276 . P713 k�150 01510ZS2611417B2 0.0600 10" 1'-4 1/2" RS01EJ1, R541TD p7a ;640 P685. 00310ZS2811413B3 0.0880 10" .3'-10 1/2" RS02TI, RSOlUl # ( 1 ! t ( ! + P686 00410ZS2811417B3 0.0600 10" 3'-10 1/2" RS02TI, RS0lU1 V Part Mark Keya eF/ I P227 01110ZS3011417B2 0.0600 10" 2'-10 1/2" RSOiul I 00ISGA11071 I # # # # t # # t P593 00810ZS3011417B2 0.0600 10" 2'•-10 1/2" RSOIUI 2 002SGA19114 I Ids I ! # Ps43 # I # # t # P343 ! } # # O m P712 00910Z$3011416B2 0.0680 10" 2T-10 1/2" RS0lU1 3 OOISGA19007 # ( # f P711 03210ZS2206412B3 0.0980 10" RS02TI, RSOITD 4 GFAP0114 ( P710 031102S2400416B3 0.0680 I0" 1'-10 1/2" RS02TI, RS0lU1 5 001SGA11097 1@21 w f j m rb Pb98 42010ZS301141582 0.0730 10" 2'-10 1/2" RS01u1 6 OOISGA19114 f # t t P276 01910ZS2611417B2 0.0600 10" i'-4 1/2" RSOIUI, RSOITD 7 001SGA13087 t ssxaal # # 1 t { } r r +t P700 0221025290541782 0.0600 10„ 3''-10 1/2" RSOITD, RS01u1 t3 ## } P701 02310ZS281141183. 0.1130 IO" 3'-10 1/2" RS02TI, RSOIUI i P702 02410ZS281141733 0.0600 10" 3T-•10 1/2" RS02TI, ,RS01UI t ssxaal t # I # t 704 194 ; P163 Q1110ZS2811417B2 0.4600 lo" 1'-10 1/2" RS0lU1 0.0600 lo" 2'-10 1/2" t" Q' P693 OQ210Z52500417B3 RS02TI, RSOlU1 � P694 00510ZS250041683 0.0680 10" 2'-i0 1/2" RS02TI, Rs01u1 t # f f P657 01910ZS2500415B3 0.0730 10 2'-10 1/2" RS02T1, RS0lU1 �, �. ; # E # } 1 712(TYP•1 383(Typ.J 712(Fyp•) 695(Typ. P315 01210ZS3011413B2 0.0880 1Q" 2'•-10 11/21 RSolU1 sBxaoi P713 01810Z$2511414B2 0.0790 10" RS01TD ; f f t 1 # P699 021I0Z5290541482 0.079Q 10" 3'-10 I/2" RS01TD, RS01U1 7a 699 543 6sa ; FIELD LOCATE (4) P438 01710ZS2500415B3 0.0730 1fl" SUPPORT BEAMS SBX001 f t # t } SBxaO} P705 0281OZ82605417B2 0.0600 10, 1 `-4 1/2•" RSIISB, RS01U1 AS REQUIREab P743" 6s 593 4 rf t # # # { Yy P684 00110ZS2811413B3 0.08aO 10" FtS02T1, W520F2 f ka # (� ( 10 t0 t i SCJ' It t P704 02710ZS28ll4llB2 0.1130 10" 1'-4 1/2" WS2OF2, RS11SB, RSOlUl 701{,^Yp.) ...».».« ......... 64 .._ ,.«,..... 3s3 ... .«......., 693 � ( F703 02510ZS2$11411H2 0.1130 *� FIELD LJ n ......«.........a .... »... �9 _... »»..,«.ff) 7os .«« .«. _ . p 1(3 W92OP'a RS01TD ncrannxreaocreeu,zs,c { P706 02910ZS250341482 0.0790 14" RS02T1, RS11SB, RSOIUI ;' # # t 10 je. { 1� tQ I tl� # ! It la" PURLIH SEX CARRY BEAH i m- � � # f # t t E # # I (SHSPPED LC03E} o { 685(Typ,1 709{Typ•t (9i>;LD LOCATED BY a ;53(Typ.! 707(2yP.) 709(Typ.) 6" DROP B11411Y4- TYPICAL OTkERS! # # E t' 1/a" CLIP PG1 TYPICAL CLIP PGI Pur lin Support Beam SBX001 GC5 CLIPS # CPO FIELD CUT r iiEADER FOI AS REQ�D Ta Fir (4) 56101 Tr~x-s scREs s �Fq. BEAM LOCATION {4) 56101 S.D.SCREWS F03 FQ2 (BY OTHERS) FIELD WORKED TO # E # t ! t # t ' F04 MISS CLIP HOLES II rl ''' Purlin o , DETAIL 1IJE� I: 1�:•:3 #t:�.::i t # 1 [ # t ! #40 AD ;ti �w C�6sa Tia If ?ae n Purli:n h # } } } } } } 1 f Support Be m SBX001 CURB WIVEH cuRe WIDTH Curb Support Framirl Schedule (FIELD LOCATED WHERE REQUIRED) P664—� Id Width Length JAMBS HEADERS FOI 3 S 1/2 6 4 1/4 J9 00310JS0304411 S X # F02 4'•-2 3/4" 7'-7 7/8" J9 00310JS0304411 SBX001 # ► I ! # t ; {{{ I F03 61-2 1/4" 3'-5 1121 J9 00310JS0304411 J6 00110JS0601611 # # 04 6'-7 3/4" 31-2 1/2„ J9 00310JS0304411 J7 00210JS0607211 � M M '� 4so ^� lsa `" "' 410 +� 711 n► 9485 ...�..»«. t..w�ww.r..wW.n..g195 ... 9117{ 194. :1174 19tl ..•••....� �. }• »��.w+"..w.982(Ylipl : 17S{plpr 179IPllp} #?}}#h11p 2001!'1 ? , ERECTOR NOTE � LwM,S.«�. ..... «» .. ...... .. -. .» .. _....a,1/«...........-..;« «. »« ... � .... ... � � ... «.....� .. ,. »w....•.........� ... •n. .M. qw 1 �, .. .. .. W «M,.�wMM p. atom W 2R1$3 2R1B,S 2R1B5. 2RI96 R187 �� .w PRIOR TO LOCATING THE CURB SUPPORT [. 21US2 MEMBERS, IT IS R.EG`OMMENDED TO (.Z""" 7`-z" •�- '..»�:""`"" 16•-a" 28'-0" 25. 0• 25•-a"• .w....«:. .w..... 4 STUDY THE ROOF PANEL LAYOUT AND PURLINS ARE NOT BE CUT FOR f.RAMEA LOCATE THE MEMBERS SO THE ROOF OPENINGS. LOCATE FRAMED OPENINGS 122�_7� PANEL SEAMS WILL STRATEGICALLY TO SUIT DUCT WORK. BL al OCT. 2D5 S 3 S/8" FALL WHERE` NEEDED TO PROPERLY FIT 4 6" ROOF CURBS (NOT BY BUTLER). ROOF SECONDARY PLAN 3 21;-9 15/16" 2 4••-4 11/16" 1* 3'�w 9 3./8" V. Q Dimens•i.on Key 5h>3pe Name = Bowling€.arras FOR CONSTRUCTION Cit kW . iil Liw; S a0'#'!~D ltS6 '!l Xis f12 A3 5•N 8Cil.T AND l+ UT 41120 ENGINEERS SEAL APPLIES # f� T � T #=RQP'ERTY (4 Q} ..... THE BUTLER MFG ENGIN ER PL TH s DRAWING, THF—INFORMATION MA ION HEREON,. EMA I .H� :.• SUTLE MANUFACTURING u![3 iAtAB.I I. r SNt1G t3Ht` N,�ok.Ts' AOR A ..b; Bi NpA( Y' CQf N C ?N ONLY Tt3 THE II C#RK Pf30Di T (3� BUTI,I"R ©Iw BUT3:ER MFG.. IT I :PRt)YIt3EQ QLE#:Y irUR EKCTiI THS OUILb WO 6E$ . RIBED ROOF SECONDARY PLAN !. :... .:... .....:.....:.. ,.: '� .. ............ ...... .. • .. ....... ........... :,.... .. � f;�4Q GI�Ni~$5�1= 6T. #�#NSA� �!r't'Vtt, !i♦i4 �9p2 • . s ' THE '.A, I 2. it �. _RACi~B AIfLB.AN .. eW.M. i AR'(' t . E &. ABit"i'6Y Q. MFf#. a ©ESiGN ANG.PERF4Ri ANCE iN TH APPLICABLE P CHASE OR R ANQ SHALL NQQT OR MODIFt o �PR.0 C.Q Oa ,� , �-? .......... AN UR • til~ .. I A . #� RL' #€ t&A I, EO PRtdit Y4 ERECi}4N ros a TVRA#«.BfT.iVI. �1N.a..#1...... t'it! . ......... .. ..... B M RE£I�iREiu3ENTS SP1AC #Ei . Y , t1TLEf ... USfwl? FOR ANY.b1`HE f PUR ?QSE WtTM(713T Pf #QR WRITTEN APPROVAL QF 8.1,1TI,.EO...F 5.. Y:. OEseRrt?Tr�ta #4uru�ER:.. 3a�#cr$1� �r3sfructl n: E T : `15 -Qt398�{32 Qis iNAt.#� i4!?t i S {= T#�IE HUTLE t Mi±G. i~N.C�.INEtwR'S &irAL cats .. �. :. curoi ~'""..:..: a JAN 1 9 2016 R#T 'N O A CO PON i. S P ei '9cf. 3.•RF.lgilAL Cl�i A)Ix."�' bD F i i!A E i RIHI 17 NOT APPY t3. THE I MANCE OR THE S NInRAt iTt ACTpa AN 1b1 E.RE Ok I �.Ek.Y R 51?Cil<ISIt3t.E R ". $f�(31#5 bEStC14.OF ANY WAR IORt�DUCT OR ACCiJt�ATE GQC3i� flUt�f.t'iY 11�QRK�rIArNS�1#�! tN ER�T�MG TMIS BUI f�if�"1t� :�acar,ara: Tult�nnia WaS#rirr :. s . HRt1CHECK - - .. .. . .. .. t T tAuati .GALL.siViii CENTER CflMPf3N IVT FURNISHED Y B.l�iLiwR EXOEPT ACCCiRaANCE W#TH TNIB i RA vI#VG, Q T�40 AF-FE �tENCE13 IIB ...:. ; ! . ( .. .. #'Ri}J�CF: Famtl..'.#=tin C.43riY6c :: .. � " '�'' tiles N.. tai r : €N .TRY s ANOARDS PERT-AW NG e.: a r►�.. c d TQ.ANt DESIGN OR-PE:. ,APPUCAI.E sUTI E..MirtaRET#0 . . U ..3, AN ... ..... .............. . Y #� TO i C2PE#x REC i #4N IN LtiE #[NCa 3`Hlw' QOF#RE i` 4 i+ TEMPG�i�ARY # RA# IA#G. oRat�nrx; sc.n1 eci€sae t as $ f' vAc vt"fok: REQtMENTS SP+r€F}E~Q B BUTLER, P #w C NTS.. �. . ,. t+r�xa•rs �.•ae:a4) ,�t�4` gold" , aQirisldria4.9f ar?no uPG�ILENAv1dE:4B2'.I•Wr4 ... ACB,{tiG :n � . � � �(.'' y } �r F E}1/[ . € t. t{t;?r % I :'• � ?r"�f ( I - :. ROOF CURB FLANGE ENNER "STRUCTURAL" CURB VERIFY THAT THE j (2) i /4"x7/P'r S.S. OUTER CURB HAS S.D.S. {037409}A&ENOUGH CLEARANCE AT EACH INNER CURB AROUND THE INNER BOTTOM FLANGE RTU DUCT WORK CURB FOR EXPANSION PURLIN CONNECTION AND CONTRACTION (MIN. 1-1/2" EACH SIDE) a .. INNER CURES SUPPORT BEAM ! ,. CURB TO PURLIN CONNECTo \� �- '..., INNER ROOF ,' 1 lip (SHOWN) PURLIN (TYP.) OUTER CURB REMOVED FOR �,� �` rCLARITY. �.� i ��\` ;�' s � � �•.,� MR -24 ROOF I �i�� ��' 101 ! INNER .��'" CURB14 _ ,It �` OUTER CURB DOUBLE WALL CURB DETAIL I i BUILDING MAIN FRAME NOTES; ! I I 1. A DOUBLE WALL CURB IS TYPICALLY USED WHEN THE RTU (ROOF TOP UNITS WEIGHT f WEIGHT EXCEEDS THE CAPACITY OF THE STANDARD IFCURS AND KITCURB PRODUCTS. 2. IF THE LOADS ARE TOO HIGH FOR THE PURLINS, EVEN WITH THICKER PURLINS, OR IF i THERE ARE PURLINS RUNNING UNDER THE CURB THAT REQUIRE BEING GUT, THEN IT IS' RECOMMENDED TO INSTALL CARRY BEAMS. THE CARRY BEAMS SHOULD HAVE THEIR TOP FLANGE LOCATED 7" BELOW THE TOP FLANGE OF THE ROOF BEAMS AND SHOULD BUILDING BE INSTALLED WITH THEIR WEBS PERPENDICULAR TO THE OUTER FLANGE OF THE ROOF MAIN FRAME BEAMS. FOR STEEPER ROOF SLOPES, THE CARRY BEAMS SHOULD BE CLOSELY REVIEWED I FOR ANY ADDITIONAL TORSIONAL OR WEAK AXIS LOADS. THE CARRY BEAMS ARE P.ERPENDicULAR TO THE ROOF TO ALLOW THE INNER CURB' SUPPORT ' BEAMS INNER RQOF CURB CC} NECTIaN EASILY INSTALLED BETWEEN THE CARRY BEAMS AND THE PURLINS. ., 3. THE INNER STRUCTURAL CURB ATTACHES DIRECTLY TO THE PURLINS BELOW IT. IN CASES WHERE THE POR.LIN DOES NOT CONTINUE THROUGH' THE CURB OPENING, THE PURLIN SHOULD ALWAYS ATTACH TO THE INNER CURB 'SUPPORT BEAMS. VERIFY THAT THE OUTER CURB HAS ENOUGH CLEARANCE AROUND THE INNER CURB FOR EXPANSION AND �.. INNER CURB CONTRACTION. 4. BRACING MAY BE REQUIRED BETWEEN THE CARRY BEAMS TO PREVENT MOVEMENT OR FLASHING �."_".r..",... ,`_.� FLASHING TWISTING. THIS SHOULD BE LOOKED AT ON A PER JOB BASIS TO DETERMINE THE REQUIREMENTS FOR THE CARRY BEAMS C>N YOUR PROJECT. ANY REQUIRED BRACING I FOR THE CARRY BEAMS SHOULD BE DETERMINED BASER UPON THE LOADS APPLIED R I� .,.. «» .», ,r..._ ...., ... _ ............, .... .......1.........._ ..» � _. r..W ,.... _. �.. ... ... � ,�..,., ,.. _ .�..._ .............. ,» ......, _.....w .� .....�. �.. _...� .. TO THE RTU (I.E. SEISMIC, WIND, ETC.} AND THE PHYSICAL CHARACTERISTICS OF THE CARRY BEAMS: BEING USED. • .' OUTER C U .: I IR'E 5. PURLIN BRACING MAY - REQUI LOCAL MODIFICATION TO WORD AROUND CURBS, A � Y I # FRAMINO, OR DUCTW-Oft- "ELEVATED t . 6. THSUPPORT E USE OF AN RTU FRAME" MAY ALSO BE USE I I ROOF TOP UNIT CAPACITIES ECCEE3ING 2or� L85.sEE DWG �PLIANC _ JAN 19 2016 ,IPERMIT CcNTER RTU OC t 02 2015 DUCT } W n WORK m: �'M.:....................... '�M _ (•1.. vel rl.. 1•�•� ,'t�'.J 5un _ C4 of Tukwila_ _ , IBUILDING MAIN FRAME I d KEYNOTES D1 EXISTING ROOF 0 4” DOWNSPOUT & OVERFLOW DAYLIGHT 1'-0" ABOVE GRADE AT SIDEWALK. ❑3 12" GUTTER ® HVAC UNITS APPROXIMATE LOCATION. DEFERRED SUBMITTAL U NOT USED © STANDING SEAM METAL ROOFING PER METAL BUILDING SUPPLIER Q7 UNIT MOUNTED MECHANICAL SCREEN ® NOT USED Q9 NEW TUBULAR RAIL HIGH PARAPET ACCESS LADDER FROM LOWER ROOF TO UPPER ROOF. FIELD VERIFY LOCATION AND SIZE. BASIS OF DESIGN: O'KEEFE'S INC. ALUMINUM LADDER WITH PLATFORM AND RETURN MODEL 503. SEE SECTION 1/A4.1 10 ROOF AND HVAC CURBS BY G.C./M.B.S. REFER TO DETAIL 12/A9.1 O CV cf) E U H NCDgM c�n� U U y m U m W CA O Opp O o - E.y O -- H N Q . U p fE f0 0 y Z o U. rnrn Ca o o CD E ch w L co N co.. Lo M N o O F- U <2' { r (D ROOF PLAN NOTES W 1. REPORT ANY DISCREPANCIES BETWEEN STRUCTURAL, MECHANICAL, PLUMBING AND ARCHITECTURAL DRAWINGS OR SPECIFICATIONS IN WRITING TO ARCHITECT IMMEDIATELY & PRIOR TO CONSTRUCTION. O 2. ROOF EQUIPMENT IS SHOWN FOR REFERENCE ONLY. VERIFY EXACT LOCATION OF EQUIPMENT WITH . O MECHANICAL / ELECTRICAL CONTRACTORS PRIOR TO COMMENCING WORK. REFER TO MECHANICAL, ELECTRICAL AND PLUMBING FOR EQUIPMENT LOCATED OR PENETRATING THROUGH ROOFING. n/ Z 3. ALL EXHAUST FANS AND WASTE VENTS TO BE A MIN. �� OF 25'(TWENTY FIVE FEET) FROM INTAKE ON ALL MAKE-UP UNITS ON ROOF. 4. NO ROOF PENETRATIONS SHALL BE ALLOWED CLOSER L W THAN 12"TO ANOTHER PENETRATION. ui 5. GENERAL NOTES LISTED ON THIS PAGE ARE NOT .I Y INTENDED TO BE AT THE EXCLUSION OF NOTES LISTED U Z ELSEWHERE; THIS DOCUMENT SET IS MEANT TO BE COMPLIMENTARY, AND NOTES LISTED ON OTHER„�y� � . SHEETS MAY HAVE BEARING/APPLICATION TO WORK Z W n SHOWN ON THIS SHEET... m U.z }� 7 Q _OWcj�Z w � _: J � v wQ -- z D>Sg Q ®�' U- C) LL. d LJ ti ROOF' PLAN LEGEND 6:12 ROOF PITCH INDICATOR. G.C. TO FIELD VERIFY ALL EXISTING ROOF SLOPES AND CONDITIONS PRIOR TO CONSTRUCTION AND ORDERING OF MATERIALS OR TRUSSES 1/&12 _ �- GUTTER DRAINAGE DIRECTION AND SLOPE ®N 1 4 finis REVISIONS NO. DATE BY A09/01/15 09/01/15 CITY A-09/08/15 CITY 0 0 A. 0 ISSUE DATES DESIGN APPROVAL: PERMIT SUBMITTAL: 07/27/15 PERMIT RECEIVED: BID DOCS: CONSTR. DOCS: