Loading...
HomeMy WebLinkAboutPermit M16-0017 - SABEY - DUCT WORK AND THERMOSTAT RELOCATION12201 TUKWIIA INTERNATIONAL BLVD M16-0017 City of Tukwila • Department of Community Development + 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-438-9350 Web site: http://www.TukwilaWA.gov MECHANICAL PERMIT Parcel No: 0923049120 Permit Number: M16-0017 Address: 12201 TUKWILA INTERNATIONAL Issue Date: 2/25/2016 BLVD BLDG B Permit Expires On: 8/23/2016 Project Name: SABEY Owner: Name: INTERNATIONAL GATEWAY WEST Address: 12201TUKWILA INTERNATIONAL BL, SEATTLE, WA, 98168 Contact Person: Name: TERESE ANDERSON Phone: (253) 796-5825 Address: 1221 SECOND AVE N, KENT, WA, 98032 Contractor: Name: HERMANSON COMPANY LLP Phone: (206) 575-9700 Address: 1221 2ND AVE N, KENT, WA, 98032- 2945 License No: HERMACLO05BJ Expiration Date: 8/25/2016 Lender: Name: Address: DESCRIPTION OF WORK: RELOCATE EXISTING DUCT WORK AND RELOCATE ONE THERMOSTAT Valuation of Work: $5,500.00 Fees Collected: $272.02 Type of Work: REPLACEMENT Electrical Service Provided by: SEATTLE CITY LIGHT Fuel type: ELECT Water District: 20 Sewer District: VALLEY VIEW SEWER SERVICE Current Codes adopted by the City of Tukwila: International Building Code Edition: 2012 National Electrical Code: 2014 International Residential Code Edition: 2012 WA Cities Electrical Code: 2014 International Mechanical Code Edition: 2012 WAC 296-466: 2014 Uniform Plumbing Code Edition: 2012 WA State Energy Code: 2012 International Fuel Gas Code: 2012 Permit Center Authorized Signature: I hearby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this development permit and agree to the conditions attached to this permit. Signa Print tures:! L? � 7 Date: Z Name: This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: Work shall be installed in accordance with the approved construction documents, and any changes made during construction that are not in accordance with the approved construction documents shall be resubmitted for approval. 2: All permits, inspection record card and approved construction documents shall be kept at the site of work and shall be open to inspection by the Building Inspector until final inspection approval is granted. 3: All construction shall be done in conformance with the Washington State Building Code and the Washington State Energy Code. 4: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of this requirement. 5: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206-431-3670). 6: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center. 7: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 8: ***MECHANICAL PERMIT CONDITIONS*** 9: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431-3670). 10: Manufacturers installation instructions shall be available on the job site at the time of inspection. PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 1800 MECHANICAL FINAL 0609 PIPE/DUCT INSULATION 0701 ROUGH -IN MECHANICAL CITY OF TUKW1 • Community Development Department Permit Center • 6300 Southcenter Blvd., Suite 100 Tuk►vila, WA 98188 hiip://www.TukwilaWA.Pov Mechanical Permit No. /6-10l7 Project No. Date Application Accepted: o/%&M, Date Application Expires: 0-74a &.0 or office use only) MECHANICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **please print** SITE LOCATION King Co Assessor's Tax No... 0923049120 Site Address: 12201 Tukwila International Blvd Bldg B Suite Number: Floor: Tenant Name: Sabey New Tenant: ❑ .....Yes 0 ..No PROPERTY OWNER Name: Sabey Construction Address: 12201 Tukwila International Blvd City: Tukwila State: WA Zip: 98168 CONTACT PERSON — person receiving all project communication Name: Terese Anderson Address: 1221 2nd Ave N City: Kent State: WA Zip: 98032 Phone: (206) 200-7804 Fax: Email: tnderson@hermanson.com MECHANICAL CONTRACTOR INFORMATION Company Name: Hermanson Company Address: 1221 2nd Ave N City: Kent State: wA Zip: 98032 Phone: (206) 575-9700 Fax: Contr Reg No.: 1qEq04ACL9qc jDy, Exp Date: 03/12/2017 Tukwila Business License No.: BUS -0994464 Valuation of project (contractor's bid price): $ 5,500 Describe the scope of work in detail: Relocate existing duct work and Relocate one thermostat Use: Residential: New .......... ❑ Replacement ........ ❑ Commercial: New .......... ❑ Replacement ........ 0 Fuel Type: Electric..... ❑ Gas ....... ❑ Other: H:\Applications\Forms-Applications On Line\201 I Applications\Mechanical Permit Application Revised 8-9-1 I.docx Revised: August 2011 Page I of 2 bh Indicate type of mechanical work being installed and the quantity below: Unit Type Qty Furnace <100k btu Furnace >100k btu Floor furnace 1. Suspended/wall/floor mounted heater Appliance vent Repair or addition to heat/refrig/cooling system Air handling unit <10,000 cfm Unit Type Qty Air handling unit >I0,000 cfin Evaporator cooler Ventilation fan connected to single duct 1. Ventilation system Hood and duct Incinerator — domestic Incinerator — comm/industrial PERMIT APPLICATION NOTES - Unit Type Qty Fire damper Diffuser Thermostat 1. Wood/gas stove Emergency enerator Other mechanical equipment Boiler/Compressor Qty 0-3 hp/100,000 btu 3-15 bp/500,000 btu 15-30 hp/1,000,000 btu 30-50 hp/1,750,000 btu 50+ hp/1,750,000 btu Value of construction — in all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the permit center to comply with current fee schedules. Expiration of plan review — applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The building official may grant one extension of time for additional periods not to exceed 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT BUILDING OWNER OR AUTHORIZED AGENT: Date: 01/25/2016 Print Name: Terese Anderson Day Telephone: (206) 200-7804 Mailing Address: 1221 2nd Ave N Kent City H:\Applications\Forms-Applications On Line\201 I Applications\Mechanical Permit Application Revised 8-9-1 l.doex Revised: August 2011 bh WA 98032 State Zip Page 2 of 2 DESCRIPTIONS • QUANTITY PAID PermitTRAK $272.02 M16-0017 Address: 12201 TUKWILA INTERNATIONAL BLVD BLDG B 0923049120 Apn: $272.02 MECHANICAL $261.56 PERMIT ISSUANCE BASE FEE R000.322.100.00.00 0.00 $32.50 PERMIT FEE R000.322.100.00.00 0.00 $176.75 PLAN CHECK FEE R000.322.102.00.00 0.00 $52.31 TECHNOLOGY FEE $10.46 TECHNOLOGY FEE TOTAL. .. R000.322.900.04.00 0.00 $10.46 $272.02 Date Paid: Tuesday, January 26, 2016 Paid By: HERMANSON COMPANY Pay Method: CREDIT CARD 893677 Printed: Tuesday, January 26, 2016 2:28 PM 1 of 1 rPWSYS7fM5 K INSPECTION RECORD Retain a copy with permit (6-00f7 INS PtL ON N0. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. `JVA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 PLC be y Type of Inspe tion: _ r /" -, �/, / Address: -r4- �i� / 4- l ✓ Dat,�JCal d: 9 96, Special Instructions: �f S (' �� l f 1 '. n� p�� Date 1N ted: a.m. , �� �'[ p.m. Renester : e ® Q r� Phone No: F] REINSPECTION FEE REQUIRED. Prior to next inspection, tee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. (16 INSPECTION RECORD �tr6-c)o 7t7 Retain a copy with permit INKCI ION NO, PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd- #100, Tukwila. WA 98188 (206) 43.1-3670 Permit. Inspection Request Line (206) 438-9350 Project: Ty j, of Inspection: A p� �C Address: Date C ed: 10 Speciallnstructions: Date anted: a.m. -3-1-1,6 p.m. Requester: S �.r S- Phone No: IInspector :j� IDate:��l `� ❑ REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. PY PLANEWRRO Pl��`VTUTING SLIP PERMIT NUMBER: M16-0017 DATE: 01/26/16 PROJECT NAME: SABEY SITE ADDRESS: 12201 TUKWILA INTERNATIONAL BLVD X Original Plan Submittal Revision # before Permit Issued Response to Correction Letter #, DEPARTMENTS: "0 N Building Division IN Public Works ❑ PRELIMINARY REVIEW: Not Applicable ❑ (no approval/review required) REVIEWER'S INITIALS: APPROVALS OR CORRECTIONS: Approved ❑ Corrections Required ❑ (corrections entered in Reviews) Notation: REVIEWER'S INITIALS: Revision # after Permit Issued AA NIA- 177)%%* Fire Prevention 6 Planning Division ❑ Structural ❑ Permit Coordinator a DATE: 01/28/16 Structural Review Required ❑ DATE: DUE DATE: 02/25/16 Approved with Conditions ❑ Denied ❑ (ie: Zoning Issues) DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: 12/18/2013 HERMANSON COMPANY LLP Home Espanol Contact Safety & Health Washington State Department of Labor & Industries HERMANSON COMPANY LLP Owner or tradesperson Principals NICOLAISEN, KNUT H, PARTNER/MEMBER BROCK, DANIEL L, PARTNER/MEMBER FOX, DEAN M, PARTNER/MEMBER HENGEL, STEPHEN A, PARTNER/MEMBER DYCKMAN,KENNETH A, PARTNER/MEMBER ROBINETT, PAUL J, PARTNER/MEMBER HERMANSON, RICHARD L, PARTNER/MEMBER ALMON, KEVIN, PARTNER/MEMBER (End: 08/05/2010) MACDONALD, JAMES, PARTNER/MEMBER (End: 08/05/2010) Doing business as HERMANSON COMPANY LLP Page 1 of 3 (Search L&I A -Z., Index. Help Mc Secure I.,&I Claims & Insurance Workplace Rights Trades & Licensing 1221 2ND AVE N KENT, WA98032-2945 206-575-9700 KING County WA UBI No. Business type 602 004 844 Limited Liability Partnership Governing persons CORP HERMANSON LLC HERMANSON GROUP; FTicense Verify the contractor's active registration / license / certification (depending on trade) and any past violations. Construction Contractor Active. Meets current requirements. License specialties GENERAL License no. HERMACL005BJ Effective — expiration 01/11/2000— 08/25/2016 Bond ._............. WESTERN SURETY CO $12,000.00 Bond account no. 929381801 Received by L&I Effective date 12/01/2005 01/01/2006 Expiration date Until Canceled https:Hsecure.Ini.wa.gov/verify/Detail.aspx?UBI=602004844&LIC=HERMACLO05BJ&SAW= 2/25/2016 MECHANICAL ABBREVIATIONS A AMPS IE INVERT ELEVATION AC AIR CONDITIONING IEER INTEGRATED ENERGY EFFICIENCY RATIO ACH AIR CHANGES PER HOUR IMC INTERNATIONAL MECHANICAL CODE ACT ACOUSTICAL CEILING TILE IN INCHES AD ACCESS DOOR IN WG INCHES WATER GAUGE ADD'L ADDITIONAL IPLV INTEGRATED PART LOAD VALUE AFF ABOVE FINISHED FLOOR KW KILOWATTS AFG ABOVE FINISHED GRADE LAT LEAVING AIR TEMPERATURE AHU AIR HANDLING UNIT LB/LBS POUND/POUNDS ALUM ALUMINUM LF/LIN FT LINEAL FOOT/FEET AMP/AMPS AMPERAGE LPG LIQUID PROPANE GAS AP ACCESS PANEL LPS LOW PRESSURE STEAM ARCH ARCHITECT LVG LEAVING BC BEADED COLLAR LWA SOUND POWER RATING LEVEL (IN DB) BDD BACKDRAFT DAMPER LWG LOW WALL GRILLE BF BELOW FLOOR LWT LEAVING WATER TEMPERATURE BHP BRAKE HORSEPOWER MAX MAXIMUM BLDG BUILDING MAU MAKE UP AIR UNIT BOD BOTTOM OF DUCT MBH 1000 BRITISH THERMAL UNITS/HOUR BOP BOTTOM OF PIPE MCA MINIMUM CIRCUIT AMPACITY BOT BOTTOM MD MOTORIZED DAMPER BS BIRD SCREEN / BLACK STEEL MFR MANUFACTURER BTU BRITISH THERMAL UNIT MISC MISCELLANEOUS BTUH BRITISH THERMAL UNITS PER HOUR MIN MINIMUM/MINUTE CAP CAPACITY MPS MEDIUM PRESSURE STEAM CC CONTROLS CONTRACTOR MT MOUNT CD CEILING DIFFUSER/CONDENSATE DRAIN MTD MOUNTED CDWR CONDENSER WATER RETURN MUW MAKE-UP WATER CDWS CONDENSER WATER SUPPLY NA NOT APPLICABLE CFM CUBIC FEET PER MINUTE NC NORMALLY CLOSED/NOISE CRITERIA CHWR CHILLED WATER RETURN NG/NGAS NATURAL GAS CHWS CHILLED WATER SUPPLY NIC NOT IN CONTRACT CLG CEILING NO NORMALLY OPEN/NUMBER COL COLUMN NPW NON -POTABLE WATER CONC CONCRETE N -R NON-RESIDENTIAL COND CONDENSATE OA/OSA OUTSIDE AIR CONN CONNECT/CONNECTED/CONNECTION OBD OPPOSED BLADE DAMPER CONT CONTINUOUS/CONTINUATION OD OUTSIDE DIAMETER/DIMENSION CONTR CONTRACTOR PCF POUNDS PER CUBIC FOOT COORD COORDINATE PD PRESSURE DROP COP COEFFICIENT OF PERFORMANCE PH PHASE CT COOLING TOWER POC POINT OF CONNECTION CU CUBIC/CONDENSER UNIT P/PRESS PRESSURE CW DOMESTIC COLD WATER/CONDENSER WATER PSI POUNDS PER SQUARE INCH DB DUCTBOARD/DRY BULB/DECIBEL PSIG POUNDS PER SQUARE INCH GAUGE DDC DIRECT DIGITAL CONTROL QTY QUANITY DEFL DEFLECTION R RETURN GRILLE/RELOCATED/RETURN DEG DEGREE/DEGREES RA RETURN AIR DIA DIAMETER RD/RND ROUND DMPR DAMPER REF REFERENCE DN DOWN REQ 'REQUIRED DWG DRAWING RESID RESIDENTIAL EXH EXHAUST RF RELIEF EA EACH RG REFRIGERANT DISCHARGE GAS EAT ENTERING AIR TEMPERATURE RL REFRIGERANT LIQUID EC EGGCRATE GRILLE/END CAP/ELEC CONTRACTOR RPM REVOLUTIONS PER MINUTE EER ENERGY EFFICIENT RATING RS REFRIGERANT SUCTION EF EXHAUST FAN S SUPPLY EFF EFFICIENCY SA SUPPLY AIR EL ELEVATION SAT SATURATION/SUPPLY AIR TEMPERATURE ELEC/ELECT ELECTRICAL/ELECTRIC SD SMOKE DETECTOR EMCS ENERGY MANAGEMENT CONTROL SYSTEM S/D SLIP & DRIVE CONNECTION ENT ENTERING S -C SEATTLE CODE EQUIP EQUIPMENT SEER SEASONAL ENERGY EFFICIENCY RATING ESP EXTERNAL STATIC PRESSURE SENS SENSIBLE EWT ENTERING WATER TEMPERATURE SL SOUND LINED EXIST EXISTING SM SHEETMETAL EXH EXHAUST SPEC SPECIFICATION F FAHRENHEIT SO SCREENED OPENING FAC FIRE ALARM CONTRACTOR SOG SLAB ON GRADE FD FIRE DAMPER SP STATIC PRESSURE FDC FIRE DEPARTMENT CONNECTION SF SQUARE FEET FF FINISHED FLOOR SS STAINLESS STEEL FIC FURNISHED AND INSTALLED BY CONTRACTOR STRUC STRUCTURAL FIO FURNISHED AND INSTALLED BY OWNER TA TRANSFER AIR FLA FULL LOAD AMPS TEMP TEMPERATURE/TEMPORARY FLEX FLEXIBLE TBD TO BE DETERMINED FLR FLOOR TOD TOP OF DUCT FOB FLAT ON BOTTOM TOS TOP OF STEEL/TOP OF SLAB FOIC FURNISHED BY OTHERS, TOT TOTAL INSTALLED BY CONTRACTOR TSP TOTAL STATIC -PRESSURE FOS FLAT ON SIDE TSTAT THERMOSTAT FOT FLAT ON TOP TYP TYPICAL FP FIRE PROTECTION UH UNIT HEATER FPM FEET PER MINUTE UNO UNLESS NOTED OTHERWISE FSD FIRE/SMOKE DAMPER V VOLT FT FOOT/FEET VD VOLUME DAMPER FUT FUTURE VEL VELOCITY FV FACE VELOCITY VERT VERTICAL G GRILLE VFD VARIABLE FREQUENCY DRIVE GA GAUGE/GALLON VOL VOLUME GALV GALVANIZED W WRAPPED DUCT GC GENERAL CONTRACTOR WB WET BULB GPM GALLONS PER MINUTE WG WATER GAUGE GRD GRILLE/REGISTER/DIFFUSER W/ WITH GWB GYPSUM WALL BOARD W/0 WITHOUT HD HEAD W/SF WATTS PER SQUARE FOOT HORIZ HORIZONTAL WSEC WASHINGTON STATE ENERGY CODE HP HORSEPOWER HR HOUR HSPF HEATING SEASONAL PERFORMANCE FACTOR HT HEIGHT HWTG HIGH WALL TRANSFER GRILLE HWR HOT WATER RETURN HWS HOT WATER SUPPLY HX HEAT EXCHANGER HZ HERTZ IBC INTERNATIONAL BUILDING CODE ICW INDUSTRIAL COLD WATER ID INSIDE DIAMETER/DIMENSION MECHANICAL LEGEND 10X10 RECT SUPPLY AIR DUCT 10� UP/TOWARD 10X10 RECT SUPPLY NR DUCT 10X1 `< DN/AWAY 10X10 RECT EXHAUST OR RETURN DUCT +10X� UP/TOWARD 10X10 ,' RECT EXHAUST OR RETURN DUCT .].DN/AWAY 100 100 ROUND DUCT - UP/TOWARD �IQLi - 110o00 '�� ROUND DUCT - DN/ AWAY -J 12X100 FLATOVAL DUCT - UP/ TOWARD 12X100; Fl,gTOVAL DUCT - DN/ AWAY 100 � DUCT OVERLAP 100 BOOT TAP 109 100 45' TAP 100 VOLUME DAMPER 100 RISE(R) & DROP(D) �TRANSITION TURNING VANES/SPLITTERS (s) DUCT MOUNTED SMOKE DETECTOR BACK DRAFT DAMPER �rw�nn FLEXIBLE DUCT -Alr> NR ROW (FORCED NR) COMBINATION FSD FIRE DAMPER SMOKE DAMPER MOTOR OPERATED DAMPER lll ACCESS DOORS SOUND TRAP FLEX CONNECTION 16X16SL I ACOUSTICALLY LINED DUCT (SL) s.QQr FABRIC DUCT CLEARANCE SUPPLY AIR DIFFUSER (WITH CORE BLANKOFF) EXISTING DUCTWORK DEMO DUCTWORK I WALL -MOUNTED GRILLE CEILING RETURN, TRANSFER OR PIPE ELBOW UP 18. PIPE ELBOW DN SHALL EXHAUST AIR GRILLE DIRECTION OF SLOPE DOWN o SLOTTED DIFFUSER (PLAN VIEW) PRESS REDUCING ASSEMBLY Q REVISION CLOUD & TRIANGLE PUMP ##0 ROUND DUCT SYMBOL i�- RL/RS ## FLATREES SYMBOL t-- LPG -s ##.0 DEG SYMBOL 2-HWS/HWR-s ® POINT OF CONNECTION z-- FOV 01-100 GRD TAG IDENTIFIER = TYPE -CFM 2 RDG -i 80 SIZE T T'STAT/TEMP SENSOR ®o CARBON DIOXIDE H HUMIDITY SENSOR SENSOR sD SMOKE DETECTOR co CARBON MONOXIDE sP STATIC PRESSURE SENSOR SENSOR EXISTING DUCTWORK MECHANICAL GENERAL NOTES 1. WORK SHALL CONFORM TO APPLICABLE CODES AND REGULATIONS, INCLUDING, BUT NOT LIMITED TO THE 2012 IBC, 2012 WSEC, & 2012 IMC. 2. DIMENSIONS ARE TO FACE OF STUD, CONCRETE, OR MASONRY UNLESS NOTED OTHERWISE. 3. DO NOT SCALE DRAWINGS. DIMENSIONS GOVERN. 4. VERIFY EXISTING CONDITIONS, DIMENSIONS, DETAILS, ETC. NOTIFY ENGINEER OF ANY DISCREPANCIES PRIOR TO PROCEEDING WITH WORK. 5. WHEN CONSTRUCTION DETAILS ARE NOT SHOWN OR NOTED FOR ANY PART OF THE WORK, DETAILS SHALL BE THE SAME AS FOR OTHER SIMILAR WORK. IF ADDITIONAL QUESTIONS REMAIN, CONTACT THE ENGINEER PRIOR TO PROCEEDING. 6. ALL STRUCTURAL OPENINGS AND PLATFORMS SHALL BE PROVIDED BY THE GENERAL CONTRACTOR UNLESS NOTED OTHERWISE. 7. DUCT SEALING AND CONSTRUCTION TO MEET SMACNA AND ENERGY CODE REQUIREMENTS. UNLESS OTHERWISE NOTED, LOW PRESSURE DUCTWORK (DOWNSTREAM OF VAV BOXES, CONSTANT VOLUME AC SYSTEMS, TOILET EXHAUSTS, ETC.) TO MEET 2" CONSTRUCTION STANDARDS WITH SEAL CLASS C. MEDIUM PRESSURE DUCTWORK (UPSTREAM OF VAV BOXES, HIGH VELOCITY EXHAUSTS, ETC.) TO MEET 4" CONSTRUCTION STANDARDS WITH SEAL CLASS A. DUCT RISERS IN SHAFTS WITH DAMPERED PENETRATIONS TO MEET 6" CONSTRUCTION STANDARDS WITH SEAL CLASS A. 8. ALL CEILING DIFFUSERS ARE 4 -WAY THROW UNLESS NOTED OTHERWISE. 9. ALL DUCT DIMENSIONS ARE CLEAR INSIDE DIMENSIONS AFTER LINING HAS BEEN ACCOUNTED FOR. 10. OUTSIDE AIR INTAKES ON ALL AIR HANDLING UNITS SHALL BE 10 FEET AWAY FROM ANY FUEL BURNING EQUIPMENT OR 3 FEET BELOW ANY PLUMBING VENT OR EXHAUST OUTLET WITHIN 10 FEET 11. ALL AIR ECONOMIZERS SHALL BE CAPABLE OF THE FOLLOWING: -0% TO 100% OF THE DESIGN SUPPLY AIR -CONTROLLED BY A CONTROL SYSTEM DETERMINING IF THE OUTSIDE AIR CAN MEET PART OR ALL OF THE BUILDING COOLING LOADS. -INTEGRATED TO PROVIDE PARTIAL COOLING EVEN WHEN MECHANICAL COOLING IS REQUIRED. 12. OUTSIDE AIR INTAKE, RELIEF, AND EXHAUST OPENINGS SHALL BE EQUIPPED WITH MOTORIZED (OR GRAVITY DAMPERS PER EXCEPTIONS IN C403.2.4.4) WHICH CLOSE AUTOMATICALLY WHEN SYSTEM IS OFF OR UPON POWER FAILURE. 13. THE CONTROL SYSTEM SHALL BE 7 -DAY PROGRAMMABLE, CAPABLE OF BEING SET FOR SEVEN (7) DIFFERENT DAY TYPES PER WEEK, AND CAPABLE OF A DEADBAND SETTING OF AT LEAST 57 (10'F FOR RESIDENTIAL BETWEEN THE HEATING AND COOLING SETPOINTS. AHU CONTROL SYSTEM SHALL INCLUDE A MICROPROCESSOR AND BE CAPABLE OF RESETTING SU PLY AIR TEMPERATURES BY REPRESENTATIVE BUILDING LOADS. 14. RECORD DRAWINGS OF THE ACTUAL INSTALLATION SHALL BE PROVIDED TO THE BUILDING OWNER WITHIN 90 DAYS OF THE DATE OF SYSTEM ACCEPTANCE PER THE WASHINGTON STATE ENERGY CODE. AN OPERATING MANUAL AND MAINTENANCE MANUAL SHALL BE PROVIDED TO THE BUILDING OWNER. ALL HVAC SYSTEMS SHALL BE BALANCED AND A WRITTEN BALANCING REPORT SHALL BE PROVIDED TO THE OWNER. HVAC CONTROL SYSTEMS SHALL BE TESTED TO ENSURE THAT THEY OPERATE IN ACCORDANCE WITH APPROVED PLANS. A PRELIMINARY COMMISSIONING REPORT OF TEST PROCEDURES AND RESULTS SHALL BE PREPARED PRIOR TO ISSUANCE OF A FINAL CERTIFICATE OF OCCUPANCY. A COMPLETE FINAL COMMISSIONING REPORT OF TEST PROCEDURES AND RESULTS SHALL BE PROVIDED TO THE OWNER. COMMISSIONING, SYSTEM BALANCING, RECORD DRAWINGS AS REQUIRED PER THE WASHINGTON STATE ENERGY CODE C408. 15. MECHANICAL SYSTEMS SHALL COMPLY WITH SEISMIC RESTRAINT REQUIREMENTS OF THE BUILDING CODE SMACNA AND ASCE 7. ALL LIFE SAFETY OR HAZARDOUS MATERIAL RELATED SYSTEMS SHALL BE DEEMED AN Ip -1.5 FOR RESTRAINT METHODS OR AS NOTED ON THE DRAWINGS. REFER TO CODES FOR INSTALLATION REQUIREMENTS AND EXCEPTIONS BASED ON SIZING, WEIGHTS AND MOUNTING HEIGHTS. 16. PROVIDE EARTHQUAKE RESTRAINTS FOR HVAC EQUIPMENT AS REQUIRED BY SMACNA SEISMIC RESTRAINT MANUAL, SEISMIC HAZARD B. WIRES FOR CEILING SYSTEM ETC. SHALL NOT BE HUNG OFF HVAC EQUIPMENT OR HVAC EQUIPMENT SUPPORTS. 17. DEMO DUCTWORK I WALL -MOUNTED GRILLE PLANS AND PIPE ELBOW UP 18. PIPE ELBOW DN SHALL DIRECTION OF FLOW WITH AN UL DIRECTION OF SLOPE DOWN AND INTERLOCK PLUG OR CAP ELECTRICAL CONTRACTOR AS APPLICABLE. PRESS REDUCING ASSEMBLY AND INSTALLED BY GENERAL SOLENOID VALVE --� PUMP 2-CHWS/CHWR-S CHILLED WATER SUPPLY/RETURN i�- RL/RS REFRIGERANT LIQUID/SUCTION t-- NG --s NATURAL GAS t-- LPG -s LIQUID PROPANE GAS 2-CDWS /CDWR-s CONDENSER WATER SUPPLY/RETURN 2-HWS/HWR-s HEATING WATER SUPPLY/RETURN Z-- COND ---s CONDENSATE z-- FOV FUEL OIL VENT 2--- FOS /FOR -s FUEL OIL SUPPLY/RETURN 2 RDG -i REFRIGERANT DISCHARGE GAS MECHANICAL GENERAL NOTES 1. WORK SHALL CONFORM TO APPLICABLE CODES AND REGULATIONS, INCLUDING, BUT NOT LIMITED TO THE 2012 IBC, 2012 WSEC, & 2012 IMC. 2. DIMENSIONS ARE TO FACE OF STUD, CONCRETE, OR MASONRY UNLESS NOTED OTHERWISE. 3. DO NOT SCALE DRAWINGS. DIMENSIONS GOVERN. 4. VERIFY EXISTING CONDITIONS, DIMENSIONS, DETAILS, ETC. NOTIFY ENGINEER OF ANY DISCREPANCIES PRIOR TO PROCEEDING WITH WORK. 5. WHEN CONSTRUCTION DETAILS ARE NOT SHOWN OR NOTED FOR ANY PART OF THE WORK, DETAILS SHALL BE THE SAME AS FOR OTHER SIMILAR WORK. IF ADDITIONAL QUESTIONS REMAIN, CONTACT THE ENGINEER PRIOR TO PROCEEDING. 6. ALL STRUCTURAL OPENINGS AND PLATFORMS SHALL BE PROVIDED BY THE GENERAL CONTRACTOR UNLESS NOTED OTHERWISE. 7. DUCT SEALING AND CONSTRUCTION TO MEET SMACNA AND ENERGY CODE REQUIREMENTS. UNLESS OTHERWISE NOTED, LOW PRESSURE DUCTWORK (DOWNSTREAM OF VAV BOXES, CONSTANT VOLUME AC SYSTEMS, TOILET EXHAUSTS, ETC.) TO MEET 2" CONSTRUCTION STANDARDS WITH SEAL CLASS C. MEDIUM PRESSURE DUCTWORK (UPSTREAM OF VAV BOXES, HIGH VELOCITY EXHAUSTS, ETC.) TO MEET 4" CONSTRUCTION STANDARDS WITH SEAL CLASS A. DUCT RISERS IN SHAFTS WITH DAMPERED PENETRATIONS TO MEET 6" CONSTRUCTION STANDARDS WITH SEAL CLASS A. 8. ALL CEILING DIFFUSERS ARE 4 -WAY THROW UNLESS NOTED OTHERWISE. 9. ALL DUCT DIMENSIONS ARE CLEAR INSIDE DIMENSIONS AFTER LINING HAS BEEN ACCOUNTED FOR. 10. OUTSIDE AIR INTAKES ON ALL AIR HANDLING UNITS SHALL BE 10 FEET AWAY FROM ANY FUEL BURNING EQUIPMENT OR 3 FEET BELOW ANY PLUMBING VENT OR EXHAUST OUTLET WITHIN 10 FEET 11. ALL AIR ECONOMIZERS SHALL BE CAPABLE OF THE FOLLOWING: -0% TO 100% OF THE DESIGN SUPPLY AIR -CONTROLLED BY A CONTROL SYSTEM DETERMINING IF THE OUTSIDE AIR CAN MEET PART OR ALL OF THE BUILDING COOLING LOADS. -INTEGRATED TO PROVIDE PARTIAL COOLING EVEN WHEN MECHANICAL COOLING IS REQUIRED. 12. OUTSIDE AIR INTAKE, RELIEF, AND EXHAUST OPENINGS SHALL BE EQUIPPED WITH MOTORIZED (OR GRAVITY DAMPERS PER EXCEPTIONS IN C403.2.4.4) WHICH CLOSE AUTOMATICALLY WHEN SYSTEM IS OFF OR UPON POWER FAILURE. 13. THE CONTROL SYSTEM SHALL BE 7 -DAY PROGRAMMABLE, CAPABLE OF BEING SET FOR SEVEN (7) DIFFERENT DAY TYPES PER WEEK, AND CAPABLE OF A DEADBAND SETTING OF AT LEAST 57 (10'F FOR RESIDENTIAL BETWEEN THE HEATING AND COOLING SETPOINTS. AHU CONTROL SYSTEM SHALL INCLUDE A MICROPROCESSOR AND BE CAPABLE OF RESETTING SU PLY AIR TEMPERATURES BY REPRESENTATIVE BUILDING LOADS. 14. RECORD DRAWINGS OF THE ACTUAL INSTALLATION SHALL BE PROVIDED TO THE BUILDING OWNER WITHIN 90 DAYS OF THE DATE OF SYSTEM ACCEPTANCE PER THE WASHINGTON STATE ENERGY CODE. AN OPERATING MANUAL AND MAINTENANCE MANUAL SHALL BE PROVIDED TO THE BUILDING OWNER. ALL HVAC SYSTEMS SHALL BE BALANCED AND A WRITTEN BALANCING REPORT SHALL BE PROVIDED TO THE OWNER. HVAC CONTROL SYSTEMS SHALL BE TESTED TO ENSURE THAT THEY OPERATE IN ACCORDANCE WITH APPROVED PLANS. A PRELIMINARY COMMISSIONING REPORT OF TEST PROCEDURES AND RESULTS SHALL BE PREPARED PRIOR TO ISSUANCE OF A FINAL CERTIFICATE OF OCCUPANCY. A COMPLETE FINAL COMMISSIONING REPORT OF TEST PROCEDURES AND RESULTS SHALL BE PROVIDED TO THE OWNER. COMMISSIONING, SYSTEM BALANCING, RECORD DRAWINGS AS REQUIRED PER THE WASHINGTON STATE ENERGY CODE C408. 15. MECHANICAL SYSTEMS SHALL COMPLY WITH SEISMIC RESTRAINT REQUIREMENTS OF THE BUILDING CODE SMACNA AND ASCE 7. ALL LIFE SAFETY OR HAZARDOUS MATERIAL RELATED SYSTEMS SHALL BE DEEMED AN Ip -1.5 FOR RESTRAINT METHODS OR AS NOTED ON THE DRAWINGS. REFER TO CODES FOR INSTALLATION REQUIREMENTS AND EXCEPTIONS BASED ON SIZING, WEIGHTS AND MOUNTING HEIGHTS. 16. PROVIDE EARTHQUAKE RESTRAINTS FOR HVAC EQUIPMENT AS REQUIRED BY SMACNA SEISMIC RESTRAINT MANUAL, SEISMIC HAZARD B. WIRES FOR CEILING SYSTEM ETC. SHALL NOT BE HUNG OFF HVAC EQUIPMENT OR HVAC EQUIPMENT SUPPORTS. 17. PROVIDE FIRE AND COMBINATION FIRE/SMOKE DAMPERS WHERE SHOWN ON PLANS AND WHERE REQUIRED PER CODE. 18. ALL PIPING PENETRATIONS THROUGH RATED ASSEMBLIES SHALL BE SEALED WITH AN UL APPROVED FIRE CAULKING. 19. SMOKE DETECTORS PROVIDING AUTOMATIC SHUTDOWN SHALL BE PROVIDED FOR HVAC EQUIPMENT DELIVERING IN EXCESS OF 2000 CFM [INCLUDING MULTIPLE UNITS DUCTED INTO COMMON DISTRIBUTION OR RETURN, WITH AN AGGREGATE SUPPLY GREATER THAN 2000 CFM] OR EACH STORY OF RETURN SYSTEMS OVER 15,000 CFM IN A MULTI -STORY INSTALLATION, PER CODE. SMOKE DETECTORS SHALL BE FIC (ELEC) UNO. POWER -WIRING AND INTERLOCK TO FIRE ALARM SYSTEM BY ELECTRICAL CONTRACTOR AS APPLICABLE. 20. MECHANICAL ACCESS PANELS SHALL BE PROVIDED BY MECHANICAL CONTRACTOR AND INSTALLED BY GENERAL CONTRACTOR. 21. ALL MOTOR STARTERS NOT SHOWN IN EQUIPMENT SCHEDULES SHALL BE FURNISHED AND INSTALLED BY ELECTRICAL CONTRACTOR. MOTOR EFFICIENCIES TO MEET OR EXCEED CODE MINIMUM. 22. FOR ALL "SEALED AIR TIGHT" SHAFTS OR ROOMS, THE FOLLOWING SHALL OCCUR: -ALL VERTICAL JOINTS & CORNERS INSIDE THE SHAFT SHALL BE PROVIDED WITH A CONTINUOUS SEAL FOR THE LENGTH OF THE JOINT, (BY GC). -TOP AND BOTTOM WALL TRACKS SHOULD BE CAULKED ALONG THEIR ENTIRE LENGTH (BY GC). -ANY FLOOR DECKING PERPENDICULAR TO THE SHAFT SHALL BE CAULKED (BY GC). )FILLING WITH ROCK WOOL IS NOT ACCEPTABLE -USE SECTIONPENETRATIONS T909.50OFTTHE52012 IBC FOR CMAX ALDLOWABOLEKLEAKAGE CONDUIT, PIPING, LLOWINGATHEBGUIDEELLINESOFOROTIGHTDSTAIR SHAFT CONSTRUCTION. -ALL DOORS SHALL BE PROVIDED WITH TIGHT FITTING GASKETS, AND OPEN AGAINST THE DIRECTION OF ROOM/SHAFT PRESSURE. 23. MAXIMUM LENGTH OF FLEXIBLE DUCT SHALL BE 12 FEET. REFER TO INSTALLATION DETAILS FOR SUPPORT REQUIREMENTS. FLEXIBLE DUCT FLAME SPREAD RATING SHALL BE < 25 AND SMOKE DEVELOPED RATING SHALL BE < 50. USE FLEXIDUCT MODEL G -KM FOR LOW AND MEDIUM PRESSURE APPLICATIONS OR APPROVED EQUAL. 24. LOCATION AND DETAILS OF EQUIPMENT DUCT ROUTING, AND CONNECTIONS ARE APPROXIMATE. COORDINATE FINAL LOCATIONS WITH OTHER TRADES. INSTALL IN ACCORDANOE WITH APPROVED SUBMITTALS AND DETAIL DRAWINGS WHEN APPLICABLE. 25. FOR RESIDENTIAL INSULATION ON DUCTWORK AND PIPING SEE ENERGY CODE CHAPTER R403. 26. ELECTRICAL METERING OF SYSTEMS AS REQUIRED BY ENERGY CODE SECTION C409 IS BY ELECTRICAL. THE ELECTRICAL DESIGN & CONTRACTOR TEAM WILL FURNISH THE NECESSARY ELECTRICAL DISTRIBUTION AND METERING COMPONENTS - SEE ELECTRICAL DRAWINGS. THE MECHANICAL CONTRACTOR WILL FURNISH A BUILDING MANAGEMENT SYSTEM CAPABLE OF COLLECTING AND STORING THE INFORMATION. A PERMANENT AND VISIBLE DISPLAY IS TO BE PROVIDED FOR EACH BUILDING, READILY ACCESSIBLE TO OPERATION AND MANAGEMENT PERSONNEL MINIMUMCT INSULATION LAST UPDATED 01/10/14 DUCT TYPE DUCT LOCATION IN HEATED AND MECHANICALLY COOLED DUCT SYSTEM INSULATION R -VALUE REMARKS SUPPLY & RETURN NOT WITHIN CONDITIONED SPACE, OUTSIDE BUILDING R-8 1,2,3 OUTSIDE AIR WITHIN CONDITIONED SPACE, INSIDE BUILDING SEE NOTES 4 & 5 1,2,3,4,5 SUPPLY & RETURN NOT WITHIN CONDITIONED SPACE: INSIDE BUILDING R-6 1,2 SUPPLY AIR <550 OR >1050 WITHIN CONDITIONED SPACE R-3.3 1,2 1 KUFtK I U tNtKbY (UUt Stl. 11UN lffU3.L./ 1 -UK I -UK I ntK KtL2U1KtIvICIV 1 J 2 INSULATED COOLED DUCTS REQUIRED A VAPOR RETARDER (PERM < 0.5) AND SEALED JOINTS 3 WEATHERPROOF BARRIER REQUIRED AROUND DUCTWORK TO MAINTAIN WATER TIGHTNESS 4 INSULATE OUTSIDE AIR DUCTS TO BUILDING EXTERIOR WALL LEVEL PER ENERGY CODE SECTION: C403.2.7.1 UNTIL CONNECTED TO EQUIPMENT SERVED OR TO THE CODE REQUIRED SHUTOFF DAMPER (THEN R-6 FOR REST OF INSTALLATION) OR HEATING & COOLING EQUIPMENT 5 R-7 CAN BE USED IN LIEU OF BUILDING ENVELOPE INSULATION LEVEL IF: DEDICATED OUTSIDE AIR SYSTEM AND LESS THAN 2,800 CFM SUPPLY AIR MINIMUMI E INSULATION LAST UPDATED: 01/10/14 FLUID DESIGN INSULATION CONDUCTIVITY NOMINAL PIPE DIAMETER (INCH) OPERATING TEMP °F CONDUCTIVITY RANGE MEAN TEMP RATING °F <1 1 TO <1-1/2 1-1/2TO <4 4 TO <8 >8 HEATING SYSTEMS (STEAM, CONDENSATE, HYDRONIC HOT WATER, DOMESTIC HOT WATER) >350 0.32-0.34 250 4.5 5.0 5.0 5.0 5.0 251-350 0.29-0.32 200 3.0 4.0 4.5 4.5 4.5 201-250 0.27-0.30 150 2.5 2.5 2.5 3.0 3.0 141-200 0.25-0.29 125 1.5 1.5 2.0 2.0 2.0 105-140 0.21-0.28 100 1.0 1.0 1.5 1 1.5 1.5 DOMESTIC COLD WATER AND HORIZONTAL RAIN LEADERS TO FIRST VERTICAL RAIN LEADER 40-60 1 0.21-0.27 1 75 1 0.5 1 0.5 1 1.0 1.0 1.0 COOLING SYSTEMS (CHILLED WATER, BRINE AND REFRIGERANT, WATERSIDE ECONOMIZER SYSTEMS)** 40-60 0.21-0.27 75 0.5 1 0.5 1.0 1 1.0 1.0 <40 0.20-0.26 75 0.5 1 1.0 1.0 1 1.0 1.5 NOT RLQUIRLD FOR 51 KA1NtK5, WN I KUL VALVtb & bALANLANC3 VALvtJ AJ'ULIA I tU vvi 1 n rlriimu 1.. UK Lc.)� IN Ulm. ** TYPICAL CONDENSER WATER PIPE IN NON -ECONOMIZER SYSTEMS DOES NOT REQUIRE INSULATION o ftft, MW/0011 Plan reviaW -Ap 7) wt.! i_ subject to errors and omsiorm. A�rovai Cii�r1rP'?;['i)r; d� llft3tn$�t 91�4tiE:`ifc? i_3 the vioisticn of airy adoWiadt codin or Rct "Pt of approvs , Fold Copy and Condi; id is e' lcklnt;:�vicd,,, r.:. : mte: 0923049120 LEGAL DESCRIPTION BEGIN NW CORNER OF NE 1/4 OF SE 1/4 TH S 89-16-35 E 100 FT TH S 24-13-53 E 969.61 FT TO POINT OF BEGINNING TH N 65-46-07 E 58.17 FT TH N 63-32-48 E 62.13 FT TH S 22-47-01 E 21.44 FT TH N 65-30-25 E 199.33 FT TO POINT ON WLY R/W LINE OF PRIMARY STATE HIGHWAY NO 1 (SR 99) SOUTH 118TH ST TO JCT SSH NO 1-K APPROVED JULY 23, 1957 TH FOLLOWING SAID WLY R/W LINE ALONG ARC OF 2805 FOOT RADIUS NON TANGENT CURVE TO RIGHT, CENTER BEARING S 65-44-51 W, THRU C/A OF 1-16-30 DISTANCE OF 62.42 FT TH FOLLOWING SAID WLY R/W LINE N 67-01-21 E 10 FT TH FOLLOWING SAID WLY R/W LINE ALONG ARC OF 2815 FOOET RADIUS NON TANGENT CURVE TO RIGHT CENTER BEARING S 67-01-21 W THRU C/A OF 6-31-21 DISTANCE OF 320.45 FT TH S 73-32-42 W 16.58 FT TH S 71-35-51 W 61.96 FT TH N 78-38-58 W 7.83 FT TH S 75-53-44 W 106.07 FT TH N 05-01-10 W 18.41 FT TH S 82-22-27 W 64.93 FT TH S 63-55-24 W 58.16 FT TH N 24-13-53 W 334.22 FT TO POINT OF BEGINNING - LOT B OF CITY OF TUKWILA BOUNDARY LINE ADJUSTMENT NO L98-0033 RECORDING NO 9810059013 SITE MAP NO SCALE ISSUE FOR PERMIT Building Today, Defining Tomorrow Hermanson Company LLP 1221 2nd Avenue North Kent, Washington 98032 Tel: (206) 575-9700 Fax: (206) 575-9800 www.hermanson.com Contractor Reg #: HERMACL0056J IGW BLDG B SUITE 140 TI 12201 TUKWILA INTERNATIONAL BLVD TUKWILA, WA 98168 REVVIStotvs Reo changes shalt I-, rad' to the scope of work withr : r print arprov2f of T�-►•'t^�;ra Gz,�}:.lir:;f t�i,,sic�~� f'�t.� s __..:��•,� +':.:,nisi �:: ;;, � r,..t :;.:a s• � i �, M Revisions 01/22/16 MIG ISSUE FOR PERMIT Date By Description Design Team Design MIG Drawn FVP Checked DTN Scale AS NOTED Drawing Number C-0582-07156 Project Number 11-16-07156 Issue Date 01/22/16 LEGEND, ABBREVIATIONS, GENERAL NOTES & SHEET INDEX -HVAC REVI:EVVED FOR RECEIVED PODE COMPLIANCE CITY OF TUINVWILA I APPROVED PERMIT CENTERCity of Tukwila BUILDING DIVISION DRAWING INDEX SHEET NO. SHEET TITLE CURRENT REVISION MO.00 LEGEND ABBREVIATIONS GENERAL NOTES & SHEET INDEX - HVAC M2.01 D PARTIAL 1ST FLOOR DEMO PLAN - HVAC M2.01 PARTIAL 1 ST FLOOR PLAN - HVAC o ftft, MW/0011 Plan reviaW -Ap 7) wt.! i_ subject to errors and omsiorm. A�rovai Cii�r1rP'?;['i)r; d� llft3tn$�t 91�4tiE:`ifc? i_3 the vioisticn of airy adoWiadt codin or Rct "Pt of approvs , Fold Copy and Condi; id is e' lcklnt;:�vicd,,, r.:. : mte: 0923049120 LEGAL DESCRIPTION BEGIN NW CORNER OF NE 1/4 OF SE 1/4 TH S 89-16-35 E 100 FT TH S 24-13-53 E 969.61 FT TO POINT OF BEGINNING TH N 65-46-07 E 58.17 FT TH N 63-32-48 E 62.13 FT TH S 22-47-01 E 21.44 FT TH N 65-30-25 E 199.33 FT TO POINT ON WLY R/W LINE OF PRIMARY STATE HIGHWAY NO 1 (SR 99) SOUTH 118TH ST TO JCT SSH NO 1-K APPROVED JULY 23, 1957 TH FOLLOWING SAID WLY R/W LINE ALONG ARC OF 2805 FOOT RADIUS NON TANGENT CURVE TO RIGHT, CENTER BEARING S 65-44-51 W, THRU C/A OF 1-16-30 DISTANCE OF 62.42 FT TH FOLLOWING SAID WLY R/W LINE N 67-01-21 E 10 FT TH FOLLOWING SAID WLY R/W LINE ALONG ARC OF 2815 FOOET RADIUS NON TANGENT CURVE TO RIGHT CENTER BEARING S 67-01-21 W THRU C/A OF 6-31-21 DISTANCE OF 320.45 FT TH S 73-32-42 W 16.58 FT TH S 71-35-51 W 61.96 FT TH N 78-38-58 W 7.83 FT TH S 75-53-44 W 106.07 FT TH N 05-01-10 W 18.41 FT TH S 82-22-27 W 64.93 FT TH S 63-55-24 W 58.16 FT TH N 24-13-53 W 334.22 FT TO POINT OF BEGINNING - LOT B OF CITY OF TUKWILA BOUNDARY LINE ADJUSTMENT NO L98-0033 RECORDING NO 9810059013 SITE MAP NO SCALE ISSUE FOR PERMIT Building Today, Defining Tomorrow Hermanson Company LLP 1221 2nd Avenue North Kent, Washington 98032 Tel: (206) 575-9700 Fax: (206) 575-9800 www.hermanson.com Contractor Reg #: HERMACL0056J IGW BLDG B SUITE 140 TI 12201 TUKWILA INTERNATIONAL BLVD TUKWILA, WA 98168 REVVIStotvs Reo changes shalt I-, rad' to the scope of work withr : r print arprov2f of T�-►•'t^�;ra Gz,�}:.lir:;f t�i,,sic�~� f'�t.� s __..:��•,� +':.:,nisi �:: ;;, � r,..t :;.:a s• � i �, M Revisions 01/22/16 MIG ISSUE FOR PERMIT Date By Description Design Team Design MIG Drawn FVP Checked DTN Scale AS NOTED Drawing Number C-0582-07156 Project Number 11-16-07156 Issue Date 01/22/16 LEGEND, ABBREVIATIONS, GENERAL NOTES & SHEET INDEX -HVAC REVI:EVVED FOR RECEIVED PODE COMPLIANCE CITY OF TUINVWILA I APPROVED PERMIT CENTERCity of Tukwila BUILDING DIVISION M M d� MAIV 0 ti PARTIAL o SCALE: 1/8" = 1'-0" N da 1ST FLOOR DEMO PLAN - HVAC AIREA 00 WORK ? S i T i 2 R M A /S 0 y KEY PLAN SCALE: NONE d � A N d a R CEIV`:D CITY OF TUKWILA JAN 2 6 2016 RERiT CENTER ISSUE FOR PERMIT Hermanson Company LLP 1221 2nd Avenue North Kent, Washington 98032 Tel: (206) 575-9700 Fax: (206) 575-9800 www.hermanson.com Contractor Reg #: HERMACL0056J IGW BLDG B SUITE 140 TI 12201 TUKWILA INTERNATIONAL BLVD TUKWILA, WA 98168 Revisions 01/22/16 MIG ISSUE FOR PERMIT No. Date By Description Design Team Design MIG Drawn FVP Checked DTN Scale AS NOTED Drawing Number C-0582-07156 Project Number 11-16-07156 Issue Date 01/22/16 PARTIAL 1ST FLOOR DEMO PLAN - HVAC REAWED FOR ¢QDE COMPLIANCE APPRQY D City of Tukwila BUILDING DIVISION \6/ (e'� --- — N AREA OF1, WOW T RECI--IV=D CITY OF TUKA!ILA JAN 26 216 PERMIT CENTER ISSUE FOR PERMIT Building Today, Defining Tomorrow Hermanson Company LLP 1221 2nd Avenue North Kent, Washington 98032 Tel: (206) 575-9700 Fax: (206) 575-9800 www.hermanson.com Contractor Reg J: HERMACL005BJ Revisions 01/22/16 MIG ISSUE FOR PERMIT No. Date By Description Drawing Number C-0582-07156 Project Number 11-16-07156 Issue Date 01/22/16 PARTIAL 1ST FLOOR PLAN - HVAC REVfEWED FOR ODE COMPLIANCE APPROVED LCity of Tukwila BUDIVISION M2.01