Loading...
HomeMy WebLinkAboutPermit M16-0018 - TOKYO TOKYO - KITCHEN MAKEUP AIR AND EXHAUST EQUIPMENTTOKYO TOKYO 1379 SOUTHCENTER MALI. M16-0018 City of Tukwila • Department of Community Development + 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-438-9350 Web site: http://www.TukwilaWA.gov MECHANICAL PERMIT Parcel No: 9202470010 Permit Number: M16-0018 Address: 1379 SOUTHCENTER MALL Issue Date: 5/11/2016 Permit Expires On: 11/7/2016 Project Name: TOKYO TOKYO Owner: 2012 Name: WESTFIELD PROPERTY TAX DEPT Address: PO BOX 130940, CARLSBAD, WA, WA Cities Electrical Code: 92013 Contact Person: 2012 Name: JAMES WASSERMAN Address: 5628 AIRPORT WAY S #112, SEATTLE, WA State Energy Code: WA, 98108 Contractor: 2012 Name: WESTERN CONSTRUCTION SRVCS INC Address: 2300 E 3RD LOOP SUITE 110, VANCOUVER, WA, 98661 License No: WESTECS162R8 Lender: Name: Phone: (206) 420-2242 Phone: (360) 699-5317 Expiration Date: 8/16/2017 Address: , , , DESCRIPTION OF WORK: REBALANCE EXISTING KITCHEN MAKEUP AIR AND EXHAUST EQUIP. INSTALL NEW TYPE 1 HOOD AND TYPE 1 GREASE EXHAUST DUCT. REBALANCE AND RECONNECT EXISTING SUPPLY AND RETURN GRILLES Valuation of Work: $9,350.00 Fees Collected: $324.28 Type of Work: REPLACEMENT Electrical Service Provided by: PUGET SOUND ENERGY Fuel type: Water District: TUKWILA Sewer District: TUKWILA SEWER SERVICE Current Codes adopted by the City of Tukwila: International Building Code Edition: 2012 National Electrical Code: 2014 International Residential Code Edition: 2012 WA Cities Electrical Code: 2014 International Mechanical Code Edition: 2012 WAC 296-46B: 2014 Uniform Plumbing Code Edition: 2012 WA State Energy Code: 2012 International Fuel Gas Code: 2012 oj Date: Permit Center Authorized Signature: I hearby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this development permit and; the conditions attached to this permit. Signatge:_ Print Name: Date: Or ( I— Z016 This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: Work shall be installed in accordance with the approved construction documents, and any changes made during construction that are not in accordance with the approved construction documents shall be resubmitted for approval. 2: All permits, inspection record card and approved construction documents shall be kept at the site of work and shall be open to inspection by the Building Inspector until final inspection approval is granted. 3: All construction shall be done in conformance with the Washington State Building Code and the Washington State Energy Code. 4: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of this requirement. 5: All construction noise to be in compliance with Chapter 8.22 of the City of Tukwila Municipal Code. A copy can be obtained at City Hall in the office of the City Clerk. 6: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206-431-3670). 7: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center. 8: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 9: `MECHANICAL PERMIT CONDITIONS' 10: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431-3670). 11: Manufacturers installation instructions shall be available on the job site at the time of inspection. 12: Type 1 Hoods, the required grease duct leakage test and Ilight test shall be performed by a special inspection and testing agency in accordance with I.M.C. Chapter 5. 13: When special inspection is required, either the owner or the registered design professional in responsible charge, shall employ a special inspection agency and notify the Building Official of the appointment prior to the first building inspection. The special inspector shall furnish inspection reports to the Building Official in a timely manner. 14: A final report documenting required special inspections and correction of any discrepancies noted in the inspections shall be submitted to the Building Official. The final inspection report shall be prepared by the approved special inspection agency and shall be submitted to the Building Official prior to and as a condition of final inspection approval. 15: The attached set of mechanical plans have been reviewed by The Tukwila Fire Marshals Office and are acceptable with the following concerns: 16: A Type 1 hood shall be installed at or above all commercial cooking appliances and domestic cooking appliances used for commercial purposes that produce grease vapors. Each required commercial kitchen exhaust hood and duct system required by section 610 of the International Fire Code to have a Type 1 hood shall be protected with an approved automatic fire -extinguishing system installed in accordance with this code. (IFC 904.2.1 and IFC 904.11) Automatic fire -extinguishing systems shall comply with UL 300 or other equivalent standards and shall be installed in accordance with the requirements of the listing. (NFPA 96, 10.2.3) 17: Type I hood systems shall be designed and installed to automatically activate the exhaust fan whenever cooking operations occur. The activation of the exhaust fan shall occur through an interlock with the cooking appliances, by means of heat sensors or by means of other approved methods. (IMC 507.2.1.1) 18: All new automatic fire -extinguishing systems and all modifications to existing automatic fire -extinguishing systems shall have fire department review and approval of drawings prior to installation or modification. 19: Local U.L. central station supervision is required. (City Ordinance #2437) 20: All new fire alarm systems or modifications to existing systems shall have the written approval of The Tukwila Fire Prevention Bureau. No work shall commence until a fire department permit has been obtained. (City Ordinance #2437) (IFC 901.2) 21: An electrical permit from the City of Tukwila Building Department Permit Center (206-431-3670) is required for this project. 22: Portable fire extinguishers shall be provided within a 30 -foot (9144 mm) travel distance of commercial -type cooking equipment. Cooking equipment involving vegetable or animal oils and fats shall be protected by a Class K rated portable extinguisher. (IFC 904.11.5) 23: Portable fire extinguishers, not housed in cabinets, shall be installed on the hangers or brackets supplied. Hangers or brackets shall be securely anchored to the mounting surface in accordance with the manufacturer's installation instructions. Portable fire extinguishers having a gross weight not exceeding 40 pounds (18 kg) shall be installed so that its top is not more than 5 feet (1524 mm) above the floor. Hand- held portable fire extinguishers having a gross weight exceeding 40 pounds (18 kg) shall be installed so that its top is not more than 3.5 feet (1067 mm) above the floor. The clearance between the floor and the bottom of the installed hand-held extinguishers shall not be less than 4 inches (102 mm). (IFC 906.7 and IFC 906.9) 24: Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (City Ordinances #2436 and #2437) 25: Any overlooked hazardous condition and/or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. 26: These plans were reviewed by Inspector 511. If you have any questions, please call Tukwila Fire Prevention Bureau at (206)575-4407. PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 1400 FIRE FINAL 0703 MECH EQUIP EFF 1800 MECHANICAL FINAL 0609 PIPE/DUCT INSULATION 0705 REFRIGERATION EQUIP 0701 ROUGH -IN MECHANICAL 0702 SMOKE DETECTOR TEST CITY OF TUKWILA Community Development Department Permit Center • 6300 Southcenter Blvd., Suite 100 TuJnvila, WA 98188 http://www.TukwilaWA.pov Mechanical Permit No. Project No. Date Application Accepted: Date Application Expires: (For office use onl MECHANICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. "please print" SITE LOCATION King Co Assessor's Tax No.: 920247-0090 Site Address: 1379 Southcenter Mall, Tukwila, WA 98188 Suite Number: Floor: 1 Tenant Name: Tokyo Tokyo New Tenant: ❑ .....Yes ®..No PROPERTY OWNER Name: Westfield Southcenter Attn: Wayne Johnson Address: 2800 Southcenter Mall City: Tukwila State: WA Zip: 98188 CONTACT PERSON — person receiving all project communication Name: James Wasserman Address: 5628 Airport Way South # 112 City: Seattle State: WA Zip: 98108 Phone: (206) 420-2242 Fax: Email. jwasserman@jjwarch.com Valuation of project (contractor's bid price): $ 9,350 Describe the scope of work in detail: MECHANICAL CONTRACTOR INFORMATION Company Name: Address: City: State: Zip: Phone: Fax: Contr Reg No.: Exp Date: Tukwila Business License No.: Rebalance existing kitchen Makeup air and Exhaust equipment. Install new type -1 hood and type -1 grease exhaust duct. Re -balance and re -connect existing supply and return grilles. Use: Residential: New .......... ❑ Replacement ........ ❑ Commercial: New .......... ❑ Replacement ........ Fuel Type: Electric..... ❑ Gas....... ❑ Other: 11:Vtpplications\Forms-Applications On Line\2016 ApplicationsWo hanical Permit Application Revised 1-4-16.docx Reused: January 2016 Page 1 Of 2 bh Indicate type of mechanical work being installed and the quantity below: Unit Type Qty Furnace <100k btu Residential, Nighttime Furnace >100k btu Industrial Floor furnace 55 dB(A) Suspended/wall/floor mounted heater 57 dB(A) Appliance vent 1 Repair or addition to heat/refrig/cooling system 47 dB(A) Air handling unit <10,000 cfm 65 dB(A) Unit Type Qty Air handling unit >I0,000 cfin Residential, Nighttime Evaporator cooler Industrial Ventilation fan connected to single duct 55 dB(A) Ventilation system 57 dB(A) Hood and duct 1 Incinerator — domestic 47 dB(A) Incinerator — comm/industrial 65 dB(A) Unit Type Qty Fire damper Diffuser Thermostat Wood/gas stove Emergency enerator Other mechanical equipment Boiler/Compressor Qty 0-3 hp/100,000 btu 3-15 h /500,000 btu 15-30 hp/1,000,000 btu 30-50 hp/1,750,000 btu 50+hp/1,750,000 btu Noise: Mechanical units need to be in compliance with the Tukwila Noise Code. Maximum permissible sound levels are based on from where the sound is created and where the sound is heard. Additionally, if sound can be heard from within a house at night in a residential zone it may not be allowed. For more details, see TMC 8.22 District of Sound Producing Source District of Receiving Property Residential, Daytime* Residential, Nighttime Commercial Industrial Residential 55 dB(A) 45 dB(A) 57 dB(A) 60 dB(A) Commercial 57 dB(A) 47 dB(A) 60 dB(A) 65 dB(A) Industrial 60 dB(A) 50 dB(A) 65 dB(A) 70 dB(A) *Daytime means 7AM-IOPM, Monday through Friday and 8AM-lOPM, Saturday, Sunday and State -recognized holidays. A few sounds are exempt from the noise code, including: Warning devices; Construction and property maintenance during the daytime hours (lam-IOpm); Testing of backup generators during the day. PERMIT APPLICATION NOTES - Value of construction — in all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the permit center to comply with current fee schedules. Expiration of plan review — applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The building official may grant one extension of time for additional periods not to exceed 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). I HEREBY CERTTFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. AUTHORIZED AGENT: Print Mailing Date: 01 • 27 • 201(0 Day Telephone: City State Zip H:\Applications\Forrm-Applications On Line\2016 ApplicationsWochanical Permit Application Revised 14-16.dm Revised: January 2016 Page 2 of 2 bh DESCRIPTIONS PermitTRAK ACCOUNT • 1 $558.86 M16-0018 Address: 1379 SOUTHCENTER MALL Apn: 9202470010 $261.92 MECHANICAL $249.45 PERMIT ISSUANCE BASE FEE R000.322.100.00.00 0.00 $32.50 PERMIT FEE R000.322.100.00.00 0.00 $216.95 TECHNOLOGY FEE $12.47 TECHNOLOGY FEE R000.322.900.04.00 0.00 $12.47 PG16-0009 Address: 1379 SOUTHCENTER MALL Apn: 9202470010 $296.94 PLUMBING $282.80 PERMIT ISSUANCE BASE FEE R000.322.100.00.00 0.00 $32.50 PERMIT FEE R000.322.100.00.00 0.00 $250.30 TECHNOLOGY FEE $14.14 TECHNOLOGY FEE TOTAL FEES PAID BY RECEIPT: R8449 R000.322.900.04.00 0.00 $14.14 Date Paid: Wednesday, May 11, 2016 Paid By: KIMBERLY KAIN Pay Method: CREDIT CARD 511180 Printed: Wednesday, May 11, 2016 1:08 PM 1 of 1 r��)/mtf SYSTEMS DESCRIPTIONS PermitTRAK ACCOUNT QUANTITY PAID $133.06 M16-0018 Address: 1379 SOUTHCENTER MALL Apn: 9202470010 $62.36 MECHANICAL $62.36 PLAN CHECK FEE R000.322.102.00.00 0.00 $62.36 PG16-0009 Address: 1379 SOUTHCENTER MALL Apn: 9202470010 $70.70 PLUMBING $70.70 PLAN CHECK FEE TOTAL FEES PAID$133.06 R000.322.103.00.00 0.00 $70.70 Date Paid: Friday, January 29, 2016 Paid By: JJW ARCHITECTS Pay Method: CHECK 3099 Printed: Friday, January 29, 2016 1:00 PM 1 of 1 SYSTEMS INSPECTION RECORD Retain a copy with permit I M16 " 001 t� INSPITTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project: oxo hyo Type of Inspection: MCC14 Jr-I�L Address: ) 3 7 CC52527 2 04A tL Date Called: Special Instructions: Date Wanted, a. -7 L1211 M. Requester: Phone No: Approved per applicable codes. LJ Corrections required prior to approval. COMMENTS: v6u'T Ilnspector: /L A,, luate: —7/1Z//� I REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION RECORD S Retain a copy with permit IM 1(c 00 16) INS TION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project: Kyo o yo Type of Ins ction: gPE Address: I �7TH(6C E AIL DCall d: Special Instructions: Date wante�h0o m. m. Requester: Phone No: ® Approved per applicable codes.a Corrections required prior to approval. inspector: NAAA IDate:.7/��/(/ I ❑ REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit IM I �C6f a INSP ON NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project: © 6 Type of Inspection: r �f Ad�iressb � � ! f ( F� Date ailed: Special Instructions: Date Wanted: a.m. — 66 p.m. Requester: Phone No: DApproved per applicable codes. Corrections required prior to approval. COMMENTS: Z e ST .J Inspector:Date: REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit 001100 IN NU.WfON N0. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Prrojet: r'O'O L O Type, f I peotion: Addrssj a Cf -r AA� D71' �u /'�"� Date Called: Special Instructions: Date Wanted: a.m. p.m. Requester: Phone No: FlApproved per applicable codes. 11 Corrections required prior to approval. Inspector:. ate: 7 ` P� REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. INSPECTION RECORD p 6 Retain a copy with permit EC 0. PERMIT N0. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 P - vu Project: o Type of Inspection: lAdftY4Date 0� r Called: Special Instructions: 't Date Wanted: a.m. -7-7— (C p.m. Requester: Phone No: Approved per applicable codes. a Corrections required prior to approval. IInspector: IDate: 7-7 ,r6 I REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. C IL INSPECTION RECORD f ( Retain a copy with permit 16 `©ol INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project: � o� Type Q)f,,Inspection: - f(s l -1'�i A dress .� a 1 .M c( Date Call . Special i structions: V r O 14- I""' Date Wanted: a.m. b -15-1b p.m. Requester: Phone No: Approved per applicable codes. Corrections required prior to approval. IInspector: y" IDatV.' ❑ REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. INSPECTION RECORD IM9 GO -Z "1 Retain a copy with permit INSPECTION NUMBER PERMIT NUMBERS CITY OF TUKWILA FIRE DEPARTMENT 206-575-4407 Projects �–�— 4A i �� a Type of Inspection: C) T-)� Address:� � � Suite #:I ��9 p� Contact Person: Special Instructions: Phone No.: Approved per applicable codes. Corrections required prior to approval. COMMENTS: Needs Shift Inspection: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: Inspector: lr_7� S 3Date: 712-1116 Hrs.: $100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. Billing Address Attn: Com an Name: Address: City: State: Zip: Word/Inspection Record Form.Doc 3/14/14 T.F.D. Form F.P. 113 PERMIT COORD COPY PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: M16-0018 DATE: 02/01/16 PROJECT NAME: TOKYO TOKYO SITE ADDRESS: 1379 SOUTHCENTER MALL X Original Plan Submittal Revision # before Permit Issued Response to Correction Letter # Revision # after Permit Issued DEPARTMENTS: � PFJ Building Division Public Works ❑ PRELIMINARY REVIEW: Not Applicable ❑ (no approvalireview required) REVIEWER'S INITIALS: APPROVALS OR CORRECTIONS: Approved ❑ Corrections Required ❑ (corrections /entered in Reviews) Notation: 'JI ►�f REVIEWER'S INITIALS: kM"b�O Fire Prevention Structural ❑ Planning Division ❑ Permit Coordinator ❑ DATE: 02/02/16 Structural Review Required ❑ DATE: DUE DATE: 03/01/16 Approved with Conditions ❑ Denied ❑ (ie: Zoning Issues) DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: 12/18/2013 WESTERN CONSTRUCTION SRS"S INC 4nWashington State Department of Labor & Industries Page 1 of 2 1101ne Pspahol Contact Search L&I ) s A-7, Index Help My I'M Safety & Health Claims & Insurance Workplace Rights Trades & Licensing WESTERN CONSTRUCTION SRVCS INC Owner or tradesperson 2300 E THIRD LOOP STE 110 VANCOUVER, WA 98661 Principals 360-699-5317 ANDREWS, KENNETH LLOYD, PRESIDENT CLARK County EDWARDS, RONALD RAYMOND, VICE PRESIDENT ANDREWS, VICKI SHANNON, SECRETARY EDWARDS, RONALD R, PRESIDENT (End: 06/20/2012) HURD-EDWARDS, JODIE L, SECRETARY (End: 06/20/2012) EDWARDS, PATRICIA A, PRESIDENT (End: 09/10/2003) EDWARDS, ROBERT D, SECRETARY (End: 09/10/2003) Doing business as WESTERN CONSTRUCTION SRVCS INC WA UBI No. Business type 600 602 277 Corporation Governing persons JODIE EDWARDS KENNETH LLOYD ANDREWS; RONALD R EDWARDS; License Verify the contractor's active registration / license / certification (depending on trade) and any past violations. Construction Contractor Active. . ........................................................................ Meets current requirements. License specialties GENERAL License no. WESTECS162R8 Effective — expiration 1212811984— 09/16/2017 Bond ................ Western Surety Co $12,000.00 Bond account no. 929595453 Received by L&I Effective date 09/09/2015 09/23/2015 Expiration date Until Canceled Bond history https://secure.Ini.wa.gov/verify/Detail.aspx?UBI=600602277&LIC=WESTECSI62R8&SAW= 5/11/2016 all, Illlllllli 1. ALL ROOFTOP UNITS, EXHAUST FANS AND MAKE -UP -AIR UNITS ARE EXISTING. CLEAN COILS, REPLACE BELTS, REPLACE FILTERS. 2. REPLACE MOTOR FOR EF -2 TO BE COMPATIBLE WITH VFD. SIZE TO 1 hp. 3. REPLACE MOTOR FOR MAU-2 TO BE COMPATIBLE WITH VFD. SIZE TO 1 hp. NOTES 0 CUT NEW DROPS THROUGH ROOF FROM UNIT. EXTEND NEW DUCTWORK TO AND TIE INTO EXISTING DUCTWORK, DIFFUSERS, GRILLES. 2O PROVIDE (1) LAYER OF 3M 615 PLUS GREASE WRAP ON GREASE DUCT. OBALANCE TO CFM SHOWN. O4 16"0 TAP TO HOOD AND TRANSITION TO 14"x14" 16 GAUGE STEEL GREASE DUCT, WELD TO HOOD. TRANSITION AND WELD TO EXISTING DUCT WORK. ALL JOINTS WELDED LIQUID TIGHT AND EITHER LIGHT TESTED OR PRESSURE TESTED. OBALANCE EF -2 TO 2,000 CFM. OBALANCE MAU-2 TO 1,450 CFM. MODIFY CONTROLS TO BE COMPATIBLE WITH ENERGY MANAGEMENT SYSTEM. CONTACT CAPTIVE-AIRE FOR WIRING DIAGRAM. 7O REFER TO HOOD DRAWING FOR TAP SIZES. N r N L I_ U) U C cav n- o CU Cn co Ncu � d U-) +) OQN� E U N Q cn co O O N N � . Lo CA 0-4— N I F. WAS it �j QA w °� 44aw �srONAL MUM 4-22-17 ( 56 56.6 57s w Lu \ _tz F- 0 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0 0 3 CD -2 525. . . . . . . . . . . . . . . . . . . . . . . CRG-G1 ' ' 1300 �. . . . . . . . . . . . . La 3 (E3E & z 2�-14„0 . TYP. 3 18"0 . . . . . . . . . . . . . . . u -h LL . ."=' 4d Z . . . . U) Eno . . . . . . . . . . .. . . . . . . . . . . . . . . . . . . . dg G'i Q CJ r . . . . . . . . . . . . . . . /.A. .. . . . . . . . . . .) Lu &a. DRAWING GE THEREON HALL NOT E DUPLICATED, 1 2 ELEVATOR .P ®E USED OR DISCLOSED TO OTHERS FOR PROCUREMENT OR OTHER PURPOSE, EXCEPT AS OTHERWISE AUTHORIZED BY . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . CONTRACT, WITHOUT PERMISSION OF . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . JET INDUSTRIES, INC. . . . • . • . . . . . . . . . 1935 SILVERTON RD. SALEM, OR 97301 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . TEL: (503) 363-2334 FAX: (503) 363-2622 . OR CCB#�S 3944, 156944,158633, 166248, 17C982 ALL REPRODUCTIONS SHALL BEAR THIS . . . . . NOTICE. I ' i 16"0 (E). . . . . . I 16"0 ILIL --- --- J Ir —i 1 112„0; C) 16"0 r I C) !! O woc) ooso E—, N 12"0 DINING I ® Z 00 O I L - —J- L — - - - 7 N, LL mho z Ll I ui F-7 ,� VJSU 16"0 EDATE ISSUE MEP BACKGROUND -------- --------- - 12.31.15 SET I 1 I I I! i II I I 1 I I I i� �EwED FOR 1.29.16 PERMIT SET M2.1 I 1/411 = 1'-0" _: ^fir .. IT `;E1IRMIT CEN11ER M2.1 2015-27-00 co T— C) O N N r W ea Lu EXHAUST RISER HANGING ANGLE 20" CAPTRATE SOLO FILTER WITH HOOK 3" INTERNAL STANDOFF IT IS THE RESPONSIBILITY OF THE ARCHITECT/OWNER TO ENSURE THAT THE HOOD CLEARANCE FROM LIMITED -COMBUSTIBLE AND COMBUSTIBLE MATERIALS IS IN COMPLIANCE WITH LOCAL CODE REQUIREMENTS. GREASE DRAIN WITH REMOVABLE CUP GAS CHASE CUTOUT (FOR GAS AND POWER LINES) LEFT AND RIGHT VERTICAL END PANELS WITH ADJUSTABLE LEGS 1/2" DIA. ALL THREAD ROE CONNECTED TO ROOF THROUGH ANOTHER HANGING ANGLE SECTION VIEW — MODEL 5430ND-2—PSP—F HOOD — # 1 (KITCHEN) CORNER HANGING ANGLE c+TrrL HANGING ANGLE 1/2" DIA. HEAVY DUTY NUT AND WASHER - ONE ABOVE ID ONE BELOW HANGING ANGLE ROD, NUTS, AND WASHERS TO BE SUPPLIED BY INSTALLING CONTRACTOR HANGING ANGLE IS PRE -PUNCHED AT FACTORY NOPY LIGHT FIXTURE - BLY, INCLUDES CLEAR THERMAL TANT GLOBE (L55 FIXTURE) ■ � r s all N ky, kyj I I ON &VLSI 1IM1111#11TA , 1 WWI _mw 23.5% OPEN STAINLESS STEEL PERFORATED PANEL Ig 1��:/_P►[071'2[em_KLei I10 1/2" DIA. ALL THREAD ROD CONNECTED TO ROOF JOIST THROUGH ANOTHER HANGING ANGLE 5411 STEEL HANGING ANGLE 1/2" DIA. HEAVY DUTY NUT AND WASHER - ONE ABOVE AND ONE BELOW HANGING ANGLE ROD, NUTS, AND WASHERS TO BE SUPPLIED BY INSTALLING CONTRACTOR HANGING ANGLE IS PRE -PUNCHED AT FACTORY BUILT ® IN ACCORDANCE WITH 0% NFPA No. 96 C t /STEO US Int®rtsk 7' 9.00"Nom./7' 9.00"OD 8'-9.00" Overall Length PLAN VIEW — Hood # I (KITCHENI 7' 9.00" LONG 5430ND-2—PSP—F 7_ m� •",.%`° �` ,�,. ��: ��. � ��" -��, - r. mom" ,r'�. JOB Tokyo Tokyo South Center Mall LOG'�.T.IO.N SEATTLE, WA, 98188 AI TB 1/8/2016 JOB REVIEWED FOR CODE COMPLIAN( APPROVED FEB 2 6 2016 City of Tukwila BUILDING DIVISI N*11PR � 1 N MEP BACKGROUND N L E U) U C ca U �- O cu U) CC) N ao ,.Y V ;., U)0-5 +� O Q Nm E 2- >_ 6�N QDO�OO cn caNN.� cu co -� m U) Q N 44856 �gars'ro�'9 EIPIIiES 4-22-17 0 0 Q THIS DRAWING DATA AND DESIGNS THEREON SHALL NOT BE DUPLICATED, USED OR DISCLOSED TO OTHERS FOR PROCUREMENT OR OTHER PURPOSE, EXCEPT AS OTHERWISE AUTHORIZED BY '. CONTRACT, WITHOUT PERMISSION OF JET INDUSTRIES, INC. 1935 SILVERTON RD. SALEM, OR 97301 TEL: (503) 363-2334 FAX: (503) 363-2622 OR CCB#'S 3944, 156944,158633, 166248,17C982 ALL REPRODUCTIONS SHALL BEAR THIS i 17Y, J CDQ W C �` F— "r -N Z co CD W U <C 0 F_�O Z) Q Z 0 SSU P�e00� cy.)�n DATE i ISSUE 12.31.15 MEP BACKGROUND SET (0 _ 1.29.16 PERMIT SET N ,.Y V ;., +� N JAN 79 2016 'ERMIT C.p rcr, III SPECIFICATION: CAPTRATE GREASE -STOP SOLO FILTER THE CAPTRATE GREASE -STOP SOLO FILTER IS A SINGLE -STAGE FILTER FEATURING A UNIQUE S -BAFFLE DESIGN IN CONJUNCTION WITH A SLOTTED REAR BAFFLE DESIGN, TO DELIVER EXCEPTIONAL FILTRATION EFFICIENCY. FILTER IS STAINLESS STEEL CONSTRUCTION, AND SIZED TO FIT INTO STANDARD 2 -INCH DEEP HOOD CHANNEL(S). UNITS SHALL INCLUDE STAINLESS STEEL HANDLES AND A FASTENING DEVICE TO SECURE THE TWO COMPONENTS WHEN ASSEMBLED. GREASE EXTRACTION EFFICIENCY PERFORMANCE SHALL REMOVE AT LEAST 75% OF GREASE PARTICLES FIVE MICRONS IN SIZE, AND 90% GREASE PARTICLES SEVEN MICRONS IN SIZE AND LARGER, WITH A CORRESPONDING PRESSURE DROP NOT TO EXCEED 1.0 INCHES OF WATER GAUGE. THE CAPTRATE GREASE -STOP SOLO WAS TESTED TO ASTM STANDARD ASTM F2519-05. FILTER COLLECTION EFFICIENCY2" Captrat®Grease-Sto®Solo Filter loo 90 80 0 70 U W 60 r-1 U w i° W ��0 40 7 30 20 W 10 0 0.1 1 10 PARTICLE DIAMETER (utn) CAPTRATE FILTERS ARE BUILT IN COMPLIANCE WITH:. NFPA #96 NSF STANDARD #2 UL STANDARD #1046 INT. MECH. CODE (IMC) N RESISTANCE VS. AIRFLOW - 2" Captrat®Grease-Sto®Solo Filter 1.6 1.4 N x 12 U 1 0.8 �? 0.6 0.4 0.2 0 0 200 400 600 800 1000 AIRFLOW (cfin) �OpBUILT Z F r�0s, IN ACCORDANCE WITH NFPA sti No. 96 e QP nU 0(§ C /STEL s II7rtek DUCT THERMISTOR SENSOR INSTALLATION NOTE: Thermistor has 2 wires that connect to control cabinet V2" NPT Quik Seal (Adapter Body) art # 32-00002 —\ Thermistor Temperature Sensor Part #A/CP-PO-4 "EXPL-HT ,2» Part PSP THERMISTOR SENSOR INSTALL NOTE: Thermistor has 2 wires that connect to control cabinet. If prewire is mounted on same hood in utility cabinet, factory wire sensors to the package per schematic. TPY2" NPT Quik Seal (Adapter Body) Part # 32-00002 op of PSP External Surface) 1 1/8' - 1 1/4' Diameter Hole 1/2" Quik Seal (Lock Washer) Part #32-00002 1/2" Quik Seal (Gasket) Part # 32-00002 BUILT IN 'ACCORDAINCE gyNo. 96 oo m Extension Ring 59361-1/2 Thermistor Temperature Sensor Part #A f CP -PO -4 "EXPL-HT Junction Box Part # 58361-1/2 1/2" Conduit Lock Nut Fort #LN101SC Extension Ring Cover 100 -BW el as MUA Stat or Stat as necessary Duct iI Surface) 1 1/8' - 1 1/4' Diameter Hole Washer) NPT Quik Seal (Nut) #32-00002 "NOTE: EXTENSION RING TO BE TACK WELDED TO DUCT OR RISER Ring Cover Must remain towards center but can adjust towards ECP to avoid riser Interference JOB Tokyo Tokyo South Center Mall LOCATION SEATTLE, WA, 98188 .DATE 1/8/2016 JOB # .DX0 # 3 1OR4 yYN RZV SCALE CODE CORflPLIA APPROVED FEB 2 6 201 City of Tukwil BUILDING DTVI 1ON N r 9 = r PERMIT SET N E (D U _ U _C13 n- O �U)o z J — LU 42�2�� d - Q � zoo O Q N � E Qi��tN UJ V• ¢a�o � �j (I -0q NoN � .� a) -� Ln W iz 4- ai 4Ub6 1 `pSIoxAL tit Kanffi 4-22-17 THIS DRAWING DATA AND DESIGNS THEREON SHALL NOT BE DUPLICATED, USED OR DISCLOSED TO OTHERS FOR PROGUREMENT OR OTHER PURPOSE, EXCEPT AS OTHERWISE AUTHORIZED BY CONTRACT, WITHOUT PERMISSION OF JET INDUSTRIES, INC. 1935 SILVERTON RD. SALEM, OR 97301 TEL: (503) 363-2334 FAX: (503) 363-2622 OR CCB#'S 3944, 156944, 158633, 166248, 17C982 ALL REPRODUCTIONS SHALL BEAR THIS 2 NOTICE. 9 = n PERMIT SET 00 CDCOF- � W _ C) _ z J — LU OC) d - Q � zoo W LL UJ o o � Q z O J W C1 ® M <C THIS DRAWING DATA AND DESIGNS THEREON SHALL NOT BE DUPLICATED, USED OR DISCLOSED TO OTHERS FOR PROGUREMENT OR OTHER PURPOSE, EXCEPT AS OTHERWISE AUTHORIZED BY CONTRACT, WITHOUT PERMISSION OF JET INDUSTRIES, INC. 1935 SILVERTON RD. SALEM, OR 97301 TEL: (503) 363-2334 FAX: (503) 363-2622 OR CCB#'S 3944, 156944, 158633, 166248, 17C982 ALL REPRODUCTIONS SHALL BEAR THIS 2 NOTICE. DATE IISSUE 12.31.15 J 1.29.16 PERMIT SET J Q 5 C) 'A iLA CD J — W OC) d - Q � zoo W W N � o � Q z O J W ® M <C F— CL DATE IISSUE 12.31.15 MEP BACKGROUND SET 1.29.16 PERMIT SET 'A iLA M4.3 2015-27-00 TER C0 T_ N N 1 W C� G W CL s N r r N cn E C U (IIS+ .� U �- O cu U) co CD 00 C'4 CD 4 O Lo cu Q N . E Q>00 U L N 0 N TEMPERATURE SENSOR Q J3 M _ c VJ 'c^ N NCo CD .� Giclrl (`nn nontinn +n I7n, i+or nr C+hnrnet C..dtnh -3 Ltd Q 4— a) 44856 ki �joxaL � MUM 4-22-17 THIS DRAWING DATA AND DESIGNS THEREON SHALL NOT BE DUPLICATED, USED OR DISCLOSED TO OTHERS FOR PROCUREMENT OR OTHER PURPOSE, EXCEPT AS OTHERWISE AUTHORIZED BY CONTRACT, WITHOUT PERMISSION OF JET INDUSTRIES, INC. 1935SILVERTON RD. SALEM, OR 97301 TEL: (503) 363-2334 FAX: (503) 363-2622 OR CCB#'S 3944, 156944, 158633,166248, 170982 ALL REPRODUCTIONS SHALL BEAR THIS NOTICE. J J Q a MEP BACKGROUND SET Vol PERMITSET O O -'� s ry LU � A, U) W O us i 41JcbW V O W LL O U cy.) Ozz�: Q .V- F— n Q THIS DRAWING DATA AND DESIGNS THEREON SHALL NOT BE DUPLICATED, USED OR DISCLOSED TO OTHERS FOR PROCUREMENT OR OTHER PURPOSE, EXCEPT AS OTHERWISE AUTHORIZED BY CONTRACT, WITHOUT PERMISSION OF JET INDUSTRIES, INC. 1935SILVERTON RD. SALEM, OR 97301 TEL: (503) 363-2334 FAX: (503) 363-2622 OR CCB#'S 3944, 156944, 158633,166248, 170982 ALL REPRODUCTIONS SHALL BEAR THIS NOTICE. DATE J J Q 12.31.15 MEP BACKGROUND SET Vol PERMITSET O O -'� s ry LU � r- W O i V O W U cy.) Q .V- F— n DATE ISSUE 12.31.15 MEP BACKGROUND SET 1.29.16 PERMITSET JAN 19 2016 M4.4 2015-27-00 T- 0 0 N TT� VJ N W U) F- 75 LIJ