Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Permit M16-0019 - ENDERS - RTU REPLACEMENT
ENDERS 4495 S 134 PL IT f[�III�!: City of Tukwila • Department of Community Development • 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-438-9350 Web site: http://www.TukwilaWA.Rov MECHANICAL PERMIT Parcel No: 2613200084 Permit Number: M16-0019 Address: 4495 S 134TH PL BLDG A Issue Date: 2/23/2016 Permit Expires On: 8/21/2016 Project Name: ENDERS Owner: Name: REALTY ASSOCIATES FUND X LP Address: 1301 DOVE ST#860, NEWPORT BEACH, WA, 92660 Contact Person: 2012 Name: JESSE CHUTICH Address: 3202 C ST NE, AUBURN, WA, 98002 Contractor: 2014 Name: COMFORT MECHANICAL INC Address: 3202 C ST NE, AUBURN, WA, 98002 License No: COMFOM1015LA Lender: 2012 Name: 2012 Address: , , , DESCRIPTION OF WORK: REPLACE (1) 4 -TON RTU LIKE FOR LIKE Phone: (425) 251-9840 Phone: (425) 251-9840 Expiration Date: 4/25/2016 Valuation of Work: $6,316.00 Fees Collected: $285.10 Type of Work: REPLACEMENT Electrical Service Provided by: SEATTLE CITY LIGHT Fuel type: ELECT Water District: 125 Sewer District: TUKWILA SEWER SERVICE,VALLEY VIEW SEWER SERVICE Current Codes adopted by the City of Tukwila: International Building Code Edition: 2012 National Electrical Code: 2014 International Residential Code Edition: 2012 WA Cities Electrical Code: 2014 International Mechanical Code Edition: 2012 WAC 296-4613: 2014 Uniform Plumbing Code Edition: 2012 WA State Energy Code: 2012 International Fuel Gas Code: 2012 c Permit Center Authorized Signature: - Date: I hearby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this development permit and agree to the conditions attached to this permit. Signature: Date: 2 G Print Name: TG ES C- �c This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: Work shall be installed in accordance with the approved construction documents, and any changes made during construction that are not in accordance with the approved construction documents shall be resubmitted for approval. 2: All permits, inspection record card and approved construction documents shall be kept at the site of work and shall be open to inspection by the Building Inspector until final inspection approval is granted. 3: Readily accessible access to roof mounted equipment is required. 4: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of this requirement. 5: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206-431-3670). 6: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center. 7: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 8: ***MECHANICAL PERMIT CONDITIONS*** 9: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431-3670). 10: Manufacturers installation instructions shall be available on the job site at the time of inspection. PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 0703 MECH EQUIP EFF 1800 MECHANICAL FINAL 0609 PIPE/DUCT INSULATION 0705 REFRIGERATION EQUIP 0701 ROUGH -IN MECHANICAL 0702 SMOKE DETECTOR TEST ' CITY OF TUKWILA • + Comm unity Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.TulcwilaWA.gov Mechanical Permit No. �� l Project No. Date Application Accepted: Date Application Expires: (For office use only). MECHANICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **please print** SITE LOCATION �fr King Co Assessor's Tax No.: Z ! 3 20 " �0 9V Site Address: 17 13 c/ � �! Suite Number: Floor: Tenant Name: — n 2i S . New Tenant: ❑ .....Yes V ..No PROPERTY OWNER Name: R Address:t�c! G/ �►� {City: i -11, ss�c�g4 State: I A 5 Zip: CONTACT PERSON — person receiving all project communication Name: Jesse Chutich Address: 3202 CST NE City: Auburn State: WA Zip: 98002 Phone: (425) 251-9840 Fax: Email: ,Jesse@comfortmech.com Valuation of project (contractor's bid price): $ r316 Describe the scope of work in detail: �ep[A(-e— GS MECHANICAL CONTRACTOR INFORMATION Company Name: Comfort Mechanical Address: 3202 CST NE City: Auburn State: WA Zip: 98002 Phone: (425) 251-9840 Fax: Contr Reg No.: COMFOMIOISLA Exp Date: 04/25/2016 Tukwila Business License No.: ,c S _0 Jf 336T— CONTACT 3GS' Use: Residential: New .......... ❑ Replacement ........ ❑ Commercial: New .......... ❑ Replacement ........ 0 Fuel Type: Electric .... Gas ....... ❑ Other: H AApplicm ions\Forms-Applicm ions On Line\2011 ApplicationsWechanical Permit Application Revised 8-9-1 I.docx Revised: August 2011 - Page] of Z bh Indicate type of mechanical work being installed and the quantity below: Unit Type Qty Furnace <100k btu ' Furnace >100k btu Floor furnace Suspended/wall/floor mounted heater Appliance vent Repair or addition to heat/refrig/cooling system Air handling unit <I0,000 cfin Unit Type Qty Air handling unit >10,000 cfin Evaporator cooler Ventilation fan connected to single duct Ventilation system Hood and duct Incinerator — domestic Incinerator — comtn/industrial PERMIT APPLICATION NOTES - Unit Type Qty Fire damper Diffuser Thermostat Wood/gas stove Emergency enerator Other mechanical equipment --F Boiler/Compressor Qty 0-3 hp/100,000 btu 3-15 h /500,000 btu 15-30 hp/1,000,000 btu 30-50 hp/1,750,000 btu 50+h /1,750,000 btu Value of construction — in all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the pen -nit center to comply with current fee schedules. _ ti Expiration of plan review — applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The building official may grant one extension of time for additional periods not to excee&90 days each. The extension shall be requested in writing, and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR AUTHORIZED AGENT: Signature: / / Date: Print Name: JeSSe, (— ''A (fit r Day Telephone: "IZ5�2��- 6'90 Mailing Address: 32oZ- cS� �%r! Xf�,,r % WA f 1002 City State Zip H:\Applications\Fomts-Applications On Line\201 I ApplicationsWechanical Permit Application Revised 8-9-1 I.docx Revised: August 2011 Page 2 of 2 bh DESCRIPTIONS °PermitTRAK. r ACCOUNT QUANTITY PAID $285.10 M16-0019 Address: 4495 5134TH -PL BLDG A• Apn: 2613200084 $285.10 MECHANICAL $274.13 PERMIT ISSUANCE BASE FEE R000.322.100.00.00 0.00 $32.50 PERMIT FEE R000.322.100.00.00 0.00 $186.80 PLAN CHECK FEE R000.322.102.00.00 0.00 $54.83 TECHNOLOGY FEE $10.97 TECHNOLOGY FEE TOTAL1 R000.322.900.04.00 0.00 $10.97 Date Paid: Monday, February 01, 2016 Paid By: JESSE CHUTICH Pay Method: CREDIT CARD 211064 Printed: Monday, February 01, 2016 10:46 AM 1 of 1 CB? SYSTEMS INSPECTION RECORD Retain a copy with permit INSPECTION NO. ER""'! N0. n CITY OF TUKWILA BUIL®IIl1�C31 1A ( � 6300 Southcenter Blvd- #100, Tukwila. WA 9818 (206) 431-3670 r ermit Inspection Request Line (206) 438-9350 --t-L' J. [I D Pr -t 1=+�W5 Typeo /vl &� v�— Rddress� � � - t � � Dat(g Called: Special Instructions: f © /1 ,� ��/►�t Date Aanted. `/ a.m. j (6 p.m. Requester: Phone No:. p '+, -1 /06`6 of Ins coon. Inspector: Date: �> - -7 I El REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Cal l to schedule reinspection. INSPECTION RECORD IA(6-0d(j Retain a copy with permit ECT!ON NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Pr. "Oct� : Qhs Type of Ir_spec� � c. Address �SO I [, Da Ca led: Sp cial Instructions:441Date �tt nc W to / a.m. -!/ — i� p.m. Requester: kl(we"oCo t- Phoye No: -c(6 -3 6 Approved per applicable codes. Corrections required prior to approval. nspector: Date: 2-3 REINSPECTION FEE REQUIRED. Prior to next inspection, tee must be paid at 6300 Southcenter Blvd., Suite 100. Catl to schedule reinspection. 3T Pkg HP-Horiz 'roject: -Untitled1 12/22/201; 'repared By: 02:29PR 3T Pkg HP-Horiz Tag Cover Sheet Unit Report Certified Drawing Performance Report Unit Feature Sheet IF! 00F BILE rIJ V WED FOR )S COMPLIANCE APMOVED FEB 18 2016 Cify of TukvAla BUILC�f{ r OMSION 0 1 L A FEB 0 1 2016 PERMIT CENTER 1 of 9 Unit Report For 3T Pkg HP-Horiz Project:—Untitled1 12/22/201: Prepared By: 02:29PN Unit Parameters Description Dimensions (ft. in.) & Weight (lb.) *' Unit Model: -------------------------------------- SOTCQA04A2A6-OAOAO Unit Length:............................................................ 6' 2.375" Unit Size: --- ._ -- - -- ...... .............__......04 (3 Tons) Unit Width:... ---._...................._... - ..........3' 10.75., Volts -Phase -Hertz: ........................................................ 460-3-60 Unit Height:. ......... 2'9.375" Heating Type: ................................... .......... .Heat Pump ... Total Operating Weight: ............................... ....... 615 Ib Duct Cfg:.... .....Horizontal Supply / Horizontal Return None Standard One -Stage Cooling Refrigeration Coil Weights and Dimensions are approximate. Weight does not include unit packaging. Approximate dimensions are provided primarily for shipping purposes. For exact 5.5/6.0 kW 460/480-3-60, 4.2 kw 400-3-50 Volt Electric Heater 1 dimensions and weights, refer to appropriate product Standard Leak Horizontal EconoMi$er IV with solid-state controller 1 data catalog. Lines and Filters Condensate Drain Line Size: ...................... ------------------------- 3/4 Return Air Filter Type: Throwaway Return Air Filter Quantity: .................. .......... ............................. 2 Return Air Filter Size: .............................................. 16 x 25 x 2 Unit Configuration Medium Static Option Belt Drive AI/Cu - AI/Cu Base Electromechanical Controls Standard Packaging Warranty Information 5 -Year electric heaters (STD.) 1 -Year parts (STD.) 5 -Year Compressor (std.) No optional warranties were selected. NOTE: Please see Warranty Catalog 500-089 for explanation of policies and ordering methods. Ordering Information Part Number Description Quantity 50TCQA04A2A6-OAOAO Rooftop Unit 1 Base Unit Medium Static Option Belt Drive None None Accessories CRHEATER106A00 5.5/6.0 kW 460/480-3-60, 4.2 kw 400-3-50 Volt Electric Heater 1 CRECOMZR024A02 Standard Leak Horizontal EconoMi$er IV with solid-state controller 1 Packaged Rooftop Builder 1.39v Page 2 of 9 r SUBMITTAL -MicroMetl FORM NO. 18467-21D 8/26/2015 Submitted To Company: Job Name: Notes: FEATURES: Economizer 40 lbs., Hood 52 It For single. 2. or 3 speed indoor fan units only, models as I Economizer has 1 minimum position. Other control options are available. Contact MMC. Internal gear driven dampers, eliminate slippage and bindi associated with standard linkage. Designed specifically for down discharge applications. Easy to install. Easy to service. Factory assembled rainhood, with aluminum water entrain filters, in the outside portion of the hood. Includes new filter access door and any replacement pane For hinged filter panel option, Carrier part number CRHNGPNLO02A00 or MMC part number 0840-0200-A( must be ordered separateley in addition to the economiz • Rainhood is sloped for water runoff. All harnesses and plugs needed are included. Honeywell W7212, economizer control system. Internal, gear damper; See Attached Page for Units Part Number: ECH-SRT12SA-DOOS To be removed prior to installation. I THIS DOCUMENT IS THE PROPERTY OF MICROMETL CORPORATION AND IS DELIVERED UPON THE EXPRESS CONDITION THAT THE CONTENTS WILL NOT BE DISCLOSED OR USED WITHOUT MIROMETLS WRITTEN CONSENT' MicroMetl Corporation... Indianapolis Indiana — 1-800-662-4822, Sparks Nevada — 1-800-884-4662, Longview Texas — 1-903-248-4800 x: x ♦ 0 ♦ 0 t m- no 0 N N N a ,,IIIIIIIIIII! � I!IlVllgillga(qllq!�IIIqqlqqPql 'Iq'�Il�lllgll�gfl 'IggllqllllqlVlilqqqlul6ql �f.fllll'�Illlf IVII911gliq' i�i6lihllggi�fqlllql °i�i;IIIPJggliqi • I "Illilllllll!NlVlllq Ilq'VII Illgllligl_� N .§ 2 CL L � \ � \\ \\\\ §{j k\{) {\{ j}��`§)}\ {{\/ })» k ()/ \)]{ §/ƒ2 - /(\§ IS //i \ B §§{%§§Ek{+!!/} �lmre,9°r!:lea \ - ! { {/\[aF{\{{, ( \ Q k / S 2{kj2 /k } )§ $ _ )! }\ §{j k\{) {\{ j}��`§)}\ {{\/ })» k \)]{ /(\§ //i - §§{%§§Ek{+!!/} �lmre,9°r!:lea \ ! { {/\[aF{\{{, ( \ Q k / $k\%2 2{kj2 LIN ) Performance Summary For 3T Pkg HP-Horiz Project:—Untitled1 12/22/201: Prepared By: 02:29PN Part Number:50TCQA04A2A6-OAOAO ARISEER: ............................... _.................................. ........................................................... ... _._......... .... - --..............13.40 Base Unit Dimensions ..............................95.0 F UnitLength: ...................... .............................................. _............ .................................................................. ........... ----------------.............74.4 in UnitWidth ........ _ .............................. ...... ... ..........................................................................................._.._.........__...... - ...............46.8 in UnitHeight:..... . ....... .__.............. ........................ - -........................._.................... - - - .............33.4 in Operating Weight ................................................. .57.7 F BaseUnit Weight: ...... ..... ................._...................................................... --.................................................. . - - - - ............ 505 Ib Medium Static Option Belt Drive:.-..._......................._._..............._..._........... - -................__.............. . ......... 10 Ib Accessories ................5.50 MBH 5.5/6.0 kW 460/480-3-60, 4.2 kw 400-3-50 Volt Electric Heater:...._............._...._......__................_._..._........................_30 ............ .............- -- --------------28.90 Ib Standard Leak Horizontal EconoMi$er IV with solid-state controller:........_.............__..............._......_..........70 ............................ ...................... ............---------------3.00 Ib TotalOperating Weight ............. .....------------------------------------------------------------------------------------------------------------- ....................... ...... ........ 615 Ib Unit Unit Voltage -Phase -Hertz: ............... .._..._............................ ............ -...........____......_..............- ............................ 460-3-60 AirDischarge:...__........................___...._.._............................... .............._....__...__....... ....... ...._.............. _ .......................... Horizontal FanDrive Type:........ ........... .............................. .._._.._....._.............._..............................._......._...__.Belt ActualAirflow: ................................ .......... - ........_._............_.......... ----- .............. .............. ..- __ --- --------------............................1200 CFM SiteAltitude: .............................._......._....._............_....._...._................._..._..........___............_...... - ...._.........._.............. --- --....__..0 ft Cooling Performance CondenserEntering Air DB:....................................................................................................................-....... ..............................95.0 F EvaporatorEntering Air DB: ... ._................ ...._....._.................-....... .... _............ -.............. .._................................................ ...............80.0 F EvaporatorEntering Air WB: .................................. ...............__..........._................_.........._ ----------------------------------- .........67.0 F EnteringAir Enthalpy: - ..._............................_.......__...................................._............................ ...._........................ ...._..._........31.44 BTU/Ib EvaporatorLeaving Air DB: ----------------- ---- .._............ ............... ............................ ................................. ................................................. .57.7 F Evaporator Leaving Air WB: ......... ............. ......... .... .............. . ...................................................57.1 F Evaporator Leaving Air Enthalpy: ......................... ..........................................................-................----------....................................24.44 _............. ._.........----- ............. . ----------_7.7 BTU/Ib GrossCooling Capacity: -------------------_---.......----------------...-------------------------------------------------------------..._......------------------..........37.80 ................5.50 MBH GrossSensible Capacity: ........................... .................................................................................. ............ .............- -- --------------28.90 MBH CompressorPower Input: ............................................................................ .............. . ............................ ...................... ............---------------3.00 kW Coil Bypass Factor:. .................0.036 Heating Performance OutdoorAmbient Temperature------------- ------------ .......................................................... ---------- ---- - ----------- --- - -- - ---------------------47.0 F Entering Air Indoor Coil DB: ------------------------------------------ .......... - - - ... - - ... --- ----- - ... ..._._ .................................70.0 F Leaving Air Indoor Coil DB------------- .........................................97.3 F TotalHeating Capacity: --------- ...... -.._........................_.............................................._._..........- ...._....--------..__.._................ 5.40 MBH IntegratedHeating Capacity:.................... ................. .............. -.................... ............ ...... ...................... ..........................35.40 MBH HeatingPower Input:.... ......... -........__........._........._.._. ........ -- ....... --- .............................._........_.._............................2.84 kW HSPF:............_.._........._...__...........__........._._..........-...._.........-.......... ......_.._....................... _............. ._.........----- ............. . ----------_7.7 BHP Electric Heating Capacity: .......... ............. ............ ................5.50 kW UnitLeaving Air Temp:.__.._ ......................... .. ...................__._._...._._..........._.... ___ .............. _ .......... ........... ....... ___ ......111.8 F Supply Fan External Static Pressure: ....... - . ........... ..... - ......... _........ __.._ _..... --- ------- .._............... _............. __......... _........__...... .....0.60 in wg Options / Accessories Static Pressure ElectricHeaters: ........................................................ ._.........._...._........_. .......-._........------..._................_......................................0.07 in wg Economizer:. - - ............-._......._.................._...........------------------------........------------------..-....---.._......_...._.._.......__._.......... - 0.05 in wg Total Application Static (ESP + Unit Opts/Acc.):.---.._............................ _.... ........... ..............._._.................................................0.72 in wg FanRPM: ------------------------------------------------------------------------------ -............................. ........... ........ -....................................912 FanPower:...-------.....----............................_..._................_.. - - - ................................................... .0.53 BHP NOTE: ............... ....................................... ........_............................_._......._.-...............Selected IFM RPM Range: 819 - 1251 Electrical Data VoltageRange:.................. ......................... ................... ............ ............. -------------------------------------------- _..............................414 - 506 Packaged Rooftop Builder 1.39v Page 6 of 9 Performance Summary For 3T Pkg HP-Horiz Project:-Untitled1 12/22/2015 Prepared By: 02:29PM Compressor#1 RLA:_------ ............. -_ ............................._.................._......._............_......... - - ..._........... - ................... ---------------6 Compressor#1 LRA:_ ..................... ._..............._............__._...............----------.....-------............................ ......................... 44 Actual Electric Heater kW: .......... ................................................... ................. 5.5 ElectricHeater FLA: ................................................................................._............ - -............. ................................ .... ............ 7.2 IndoorFan Motor Type:_ .............. .......................................... ......................................... _............... - -._........_.-....................... - ..MED IndoorFan Motor FLA: _........... ....____ - - - .................._............ - ...------------ .................. ...................................... 2.5 PowerSupply MCA: .......................... __.................................... .......................................................... -...................... ................. .................... 20 PowerSupply MOCP (Fuse or HACR):.......................... ..._................_...... - - - -...............-...................................- __............. 20 DisconnectSize FLA: ..............- ..._...... - ............. -- ... - - ................__...----...----........----...._._.._..................--------------..19 59.7 DisconnectSize LRA:. .................... .... ... ...._......... --.................... - - - - -- - _........................ - - ......70 Electrical Convenience Outlet: .................... .................................................. ......................................... .... .............None Outdoor Fan [Qty / FLA(ea)]: _ .......................... ..................... ...... . .......... ...................... ......................1 /0.5 Electric Heater Number of Stages:....... - ...................................... - ........... ........__.................... .......... - -...................._.1 Control Panel SCCR: 5kA RMS at Rated Symmetrical Voltage Acoustics SoundRating:. ............................................................. ......... ........77.0 db Sound Power Levels, db re 10E-12 Wafts Advanced Acoustics Advanced Accoustics Parameters Discharge Inlet Outdoor 63 Hz 87.6 83.5 78.9 125 Hz 83.8 83.1 81.7 250 Hz 66.3 62.7 74.9 500 Hz 59.7 58.7 72.5 1000 Hz 62.7 58.8 70.3 2000 Hz 60.9 55.4 65.6 4000 Hz 61.6 55.4 65.6 8000 Hz 57.3 51.1 62.6 A -Weighted 71.5 69.0 75.8 Advanced Acoustics Advanced Accoustics Parameters 1. Unit height above ground: .................................................... 30.0 ft 2. Horizontal distance from unit to receiver: ------------------- 50.0 ft 3. Receiver height above ground:-. .......................................... 5.7 ft 4. Height of obstruction: ............._....-.................._.......................0.0 ft 5. Horizontal distance from obstruction to receiver: 0.0 ft 6. Horizontal distance from unit to obstruction: --------------- 0.0 ft Detailed Acoustics Information Octave Band Center Freq. Hz 1631125125015001 1kJ 2kJ4kJ 8kJ Overall Packaged Rooftop Builder 1.39v Page 7 of 9 Performance Summary For 3T Pkg HP-Horiz Project:-Untitled1 12/22/2015 Prepared By: 02:29PM A 78.9 81.7 74.9 72.5 70.3r33.2133.2130.2152.3 .6 65.6 62.6 84.7 Lw B 52.7 65.6 66.3 69.3 70.3.8 66.6 61.5 75.8 LwA C 46.5 49.3 42.5 40.1 37.9 LD 20.3 33.2 33.9 36.9 37.9.4 34.2 29.1 43.4 L A Legend A Sound Power Levels at Unit's Acoustic Center, Lw B A -Weighted Sound Power Levels at Unit's Acoustic Center, LwA C Sound Pressure Levels at Specific Distance from Unit, Lp D A -Weighted Sound Pressure Levels at Specific Distance from Unit, LpA Calculation methods used in this program are patterned after the ASHRAE Guide; other ASHRAE Publications and the AHRI Acoustical Standards. While a very significant effort has been made to insure the technical accuracy of this program, it is assumed that the user is knowledgeable in the art of system sound estimation and is aware of the tolerances involved in real world acoustical estimation. This program makes certain assumptions as to the dominant sound sources and sound paths which may not always be appropriate to the real system being estimated. Because of this, no assurances can be offered that this software will always generate an accurate sound prediction from user supplied input data. If in doubt about the estimation of expected sound levels in a space, an Acoustical Engineer or a person with sound prediction expertise should be consulted. FanCurve 2D ,111 ORPM13 V1 , 1B \ 9ooFRPM to \\ 12 \ 1D \ 700R Avi �. � 20DBFP T SOORPM \ .\ V.50BFP ..�-�...�_ 1.00BFP \ 0.758FP 02- 2 OC) m OD M T 09 12 15 1B 21 2 AdaN(CFM-ttaisands) RPM=912 BHP=0.53 MaxnnumRPM=2100MaximumBHP=2.00 Note: PleaseconU ctapplicationengineeringforselectionsoutsidetheshadedregion. SC-SystemCwve RP-RatedPoint Packaged Rooftop Builder 1.39v Page 8 of 9 Unit Feature Sheet for 3T Pkg HP-Horiz Project:-Untitled1 12/22/2015 Prepared By: 02:29PM Carrier WeatherMc kef- 50TCQ PACKAGED ROOFTOP HEAT PUh1P UNITS 3, 4. 5, 6, 7-112, 8-112,10 and 12.5 TONS 50TCla Units are high-efficienc•.rsingle-packagedheat pump Units that are pi e-'nrired and pre -charged with PUP.ON (HFC:) refrigerant. Electric heatis a:lailableas afield -installed accessory: The Units arefullyfactorytestedand agent, certified. PERFORMANCE FEATURES • RURC W iR-410A) H:F,, ,efaa e.5nt • SHRAE 90.1 =_n=raysom,P!lani • SEER=unto 13.4,--F.=uo to ll_2 • IEEF'9 JP to 13.2 • PGF- =JO to and -JD to 3.3 =mg- a15gE AOLrr�t 903.^.:1}' cO nl'o' ort 34 _ 07 m.od?o • ]2 C.J01'nD-SO»1V CDni on:]D-14mod='= • Exc::Jalde non -O.^0'sric OOoosrte ^Armen:s- Dan '. ss O,j9n1h SPRAE o2 Sla'nlard, ;:DD�no J?s'.o n: _;�= Dr sE raEr Jre.n • F:a%j con4'='fb-Pom •i?ri �'9,i tO nDr'.:0 n19!3!lr:O'.t• On 31! mJ:l ='a. t•:D _Deva! ci -:tv! ?J on 0<-12 moJa's. Suoo.,l Juot ktl r?qu..r=_j *or 1- _sz? m0 jet Dny. • �DPPer tubs alu-nunn Cn:.t!!='.yIn Dol 0 I -DID=.On r==GtsnI • ==-Oslnlell=A.Er.Dr Dan?''9 and o,.--.Cos!?J .nren0'Dane!-1==1-110 50:1 hDV = • Aculroln'r =1=1-1 • �oo!ing oo_rstrng rang= u0 to 115E 140 9,J dov;n to 25F 14C: • So!'d-alal?C.0n1r0'boarjand?39y9Or_e91='m.n91O'Dard • F.?fr:aers It EYer firer and sc�u mu stD-Dn =9'.n r=fr.a=>nt -.r..ua •-JIY':n9 u'3l?d cabinEt _ _ _ _ - • nJ13'n3fi: C h ano?0'ier'.•:hen USE 'd'".In a:1i D ---n an] eDvE' them" DE31 • F.9 t?J: ac:a rrL;'rs='::qn ;PF.) gts'ds'i=?<0 '.0=-05s=a9� snI 40 f0'-1 . - • rwssigmsd 'n sc'-Dr13n�z'.vgh L''n.Js,,.r1=r190 Drs ID-.-=Stanls-d 1.,35 • Li=ted by UL and UL.:snsds INSTALLATION FEATURES: • �h rJ-the-0Ol1Dm D`J::c'?n1-y Ca P3Di:Sy =_tanJard • sung'- Ooml steotri, D3nin-svOn9 • Ful. o?irt^ctsr o99E 13,4 ',vQI bu:1-1n ngg'n0 9d SOle r- 9n'J fo'+I'u C%: 3''].: RELIABILITY FEATURES: • S:ro!'rarn0ress0r_ •a• h 1n{?m�91 i:r1E,'23' over.Jgl • D?Dand9b!?-nrre`TemD_rsture defr0=t hos^J 9n -1'_g•:_ 2�-yOII OonlrJ%GrC;Ji DrotECt-1'.:-!h r___t{95•= 'J1 O=a'•-.=r ♦ P=rn-,an?nily iU o':�st=d =`i9D D'at o' -fa r" -'DI.- _ _ OIL I En..o a?J Con JE DEmla IS n!r'i '•Vor-.at- J • oEarnos • Loss ofcha'g?. f'??.e Pro!?C.r•D n. and STANDARD WARRANTY: • 5-yEs'e=pn- neap; Certified to ISO 9001 5-y=3r=DmD??= • 1-4'=5103 nE 1"la n y o pl, D n 31'.variB it- 91-0 9': 3119 5''= OPTIONS INCLUDE BUT ARE NOT LIMITED TO: • IAJ2i ProDDCol (R -U Oo=njand FrE ~•.=rL:n "' C rEct'.gaa, Gomro!!=r_ • F;a n-fus=_d d�s•cnnn=,t ;a•dch - - • EcDnDmiE'JDI'vn3 for?I?Ot rJ-nlec.ri3n=.913nil CC.'. COnfrOl • G]rrD?ion r?eral9ni CDi: OOt Ona for?v'9DD'31J'3n'J :On J?n°?r • �Pf+on9'ln'Jo0'Fan n-.OIJ.^-f0'?\Da'iJEJ a'rt 0:•: c90>Or!:t`j -asD nj ?E .irC hes! Onry! • Smo:;e detectors- SuDoiy and nEl'Jma • H:nged ac:eaa Panel_ Packaged Rooftop Builder 1.39v Page 9 of 9 f MAINTENANCE FEATURES: C Ills • .-, J... e3 Pan -da "'ah e9sygaP han1�== pa�a:a..y,nrcr • nnD''/9t!•ie.Easy 9tsimp,no=I,oa--'.v featu'E? on UnA 9Ce=B o3rei3, %,o inch dP=oo as ol- r?tum 9,r fih=_rs ����teerrr'-�-�-�••---��� �� -2" - - f'ter door • sell, '9P0 to f nmotor 9nJ oJP?ycom5n91on1 9v9119b2 ona LL�51.10 IL R -„ ' w } 7'� M'i*i"flt•"11= 9> t5 t any sPPI. _9t`on • c ct C ;e its D P?-d,ID.-:1 ct .�rD!D'Dn .. to 015 Dde9 • ?� "191!2 ^n'131D 91t3c191na `mP= E_;fct•/^rn.Jj jro J7.==h7DI'1] COMPt/AM •-_.4yFJ-L\/l,-1 and mP lGOnlnOr0DX9 7s hoz Ant INSTALLATION FEATURES: • �h rJ-the-0Ol1Dm D`J::c'?n1-y Ca P3Di:Sy =_tanJard • sung'- Ooml steotri, D3nin-svOn9 • Ful. o?irt^ctsr o99E 13,4 ',vQI bu:1-1n ngg'n0 9d SOle r- 9n'J fo'+I'u C%: 3''].: RELIABILITY FEATURES: • S:ro!'rarn0ress0r_ •a• h 1n{?m�91 i:r1E,'23' over.Jgl • D?Dand9b!?-nrre`TemD_rsture defr0=t hos^J 9n -1'_g•:_ 2�-yOII OonlrJ%GrC;Ji DrotECt-1'.:-!h r___t{95•= 'J1 O=a'•-.=r ♦ P=rn-,an?nily iU o':�st=d =`i9D D'at o' -fa r" -'DI.- _ _ OIL I En..o a?J Con JE DEmla IS n!r'i '•Vor-.at- J • oEarnos • Loss ofcha'g?. f'??.e Pro!?C.r•D n. and STANDARD WARRANTY: • 5-yEs'e=pn- neap; Certified to ISO 9001 5-y=3r=DmD??= • 1-4'=5103 nE 1"la n y o pl, D n 31'.variB it- 91-0 9': 3119 5''= OPTIONS INCLUDE BUT ARE NOT LIMITED TO: • IAJ2i ProDDCol (R -U Oo=njand FrE ~•.=rL:n "' C rEct'.gaa, Gomro!!=r_ • F;a n-fus=_d d�s•cnnn=,t ;a•dch - - • EcDnDmiE'JDI'vn3 for?I?Ot rJ-nlec.ri3n=.913nil CC.'. COnfrOl • G]rrD?ion r?eral9ni CDi: OOt Ona for?v'9DD'31J'3n'J :On J?n°?r • �Pf+on9'ln'Jo0'Fan n-.OIJ.^-f0'?\Da'iJEJ a'rt 0:•: c90>Or!:t`j -asD nj ?E .irC hes! Onry! • Smo:;e detectors- SuDoiy and nEl'Jma • H:nged ac:eaa Panel_ Packaged Rooftop Builder 1.39v Page 9 of 9 f C Ills 1L Yr-. :tlCar� • pa�a:a..y,nrcr INSTALLATION FEATURES: • �h rJ-the-0Ol1Dm D`J::c'?n1-y Ca P3Di:Sy =_tanJard • sung'- Ooml steotri, D3nin-svOn9 • Ful. o?irt^ctsr o99E 13,4 ',vQI bu:1-1n ngg'n0 9d SOle r- 9n'J fo'+I'u C%: 3''].: RELIABILITY FEATURES: • S:ro!'rarn0ress0r_ •a• h 1n{?m�91 i:r1E,'23' over.Jgl • D?Dand9b!?-nrre`TemD_rsture defr0=t hos^J 9n -1'_g•:_ 2�-yOII OonlrJ%GrC;Ji DrotECt-1'.:-!h r___t{95•= 'J1 O=a'•-.=r ♦ P=rn-,an?nily iU o':�st=d =`i9D D'at o' -fa r" -'DI.- _ _ OIL I En..o a?J Con JE DEmla IS n!r'i '•Vor-.at- J • oEarnos • Loss ofcha'g?. f'??.e Pro!?C.r•D n. and STANDARD WARRANTY: • 5-yEs'e=pn- neap; Certified to ISO 9001 5-y=3r=DmD??= • 1-4'=5103 nE 1"la n y o pl, D n 31'.variB it- 91-0 9': 3119 5''= OPTIONS INCLUDE BUT ARE NOT LIMITED TO: • IAJ2i ProDDCol (R -U Oo=njand FrE ~•.=rL:n "' C rEct'.gaa, Gomro!!=r_ • F;a n-fus=_d d�s•cnnn=,t ;a•dch - - • EcDnDmiE'JDI'vn3 for?I?Ot rJ-nlec.ri3n=.913nil CC.'. COnfrOl • G]rrD?ion r?eral9ni CDi: OOt Ona for?v'9DD'31J'3n'J :On J?n°?r • �Pf+on9'ln'Jo0'Fan n-.OIJ.^-f0'?\Da'iJEJ a'rt 0:•: c90>Or!:t`j -asD nj ?E .irC hes! Onry! • Smo:;e detectors- SuDoiy and nEl'Jma • H:nged ac:eaa Panel_ Packaged Rooftop Builder 1.39v Page 9 of 9 FILE RE WED FOR CODECQMPLIANCE APPROVED FEB 18 2016 - My of TuWla BUILDING DIVISION STRUCTURAL CALCULATIONS Enders RTU 4495 South 194th Place Tukwila, Washington JANUARY 26, 2016 !-A FEB 0 1 2016 i-rERMIT CENTER PREPARED FOR. - Comfort Mechanical 3202 C Street NE Auburn, Washington 98002 PREPARED BY: Moore Engineering Group 21902 96t', Avenue SE Snohomish, Washington 41('o vq�'m-N -t-L, Moore v I Engineering Group OV GENERAL STRUCTURAL NOTES: 2, ALL MATERIALS, WORKMANSHIP, DESIGN, AND CONSTRUCTION SHALL CONFORM TO THESE NOTES AND THE INTERNATIONAL BUILDING CODE (IBC), 2012 EDITION. DESIGN LOADING CRITERIA: ROOF LIVE LOAD ..................... 25 PSF MECHANICAL UNIT ..................... 690 POUNDS EARTHQUAKE .......................... SDs = 0.996 SITE CLASS D to E WIND .................................. 85 MPH, EXPOSURE B STRUCTURAL CALCULATIONS AND SKETCHES SHALL BE USED IN CONJUNCTION WITH MECHANICAL DRAWINGS FOR BIDDING AND CONSTRUCTION. CONTRACTOR SHALL VERIFY DIMENSIONS AND CONDITIONS FOR COMPATIBILITY AND SHALL NOTIFY ENGINEER OF ALL DISCREPANCIES PRIOR TO CONSTRUCTION. CONTRACTOR SHALL VERIFY ALL EXISTING DIMENSIONS, MEMBER SIZES AND CONDITIONS PRIOR TO COMMENCING ANY WORK. ALL DIMENSIONS OF EXISTING CONSTRUCTION SHOWN ARE INTENDED AS GUIDELINES ONLY AND MUST BE VERIFIED. THE EXISTING CONDITIONS SHOWN ON THE SKETCHES ARE BASED EITHER ON SITE OBSERVATION, ORIGINAL DRAWINGS OR WERE ASSUMED BASED ON EXPECTED CONDITIONS. IF THE EXISTING CONDITIONS DO NOT CLOSELY MATCH THE CONDITIONS SHOWN ON THE SKETCHES, OR IF THE EXISTING MATERIALS ARE OF QUESTIONABLE OR SUBSTANDARD QUALITY, NOTIFY THE ENGINEER PRIOR TO COMMENCING ANY WORK. 5. CONTRACTOR SHALL PROVIDE TEMPORARY BRACING FOR THE STRUCTURE AND STRUCTURAL COMPONENTS UNTIL ALL FINAL CONNECTIONS HAVE BEEN COMPLETED IN ACCORDANCE WITH THE DRAWINGS. 6. CONTRACTOR SHALL BE RESPONSIBLE FOR ALL SAFETY PRECAUTIONS AND THE METHODS, TECHNIQUES, SEQUENCES OR PROCEDURES REQUIRED FOR THE COMPLETION OF THE WORK. 7. FRAMING LUMBER SHALL BE KILN DRIED OR MC -19, AND GRADED AND MARKED IN CONFORMANCE WITH W.C.L.B. STANDARD GRADING RULES FOR WEST COAST LUMBER NO. 17. FURNISH TO THE FOLLOWING MINIMUM STANDARDS: JOISTS: (4x MEMBERS) HEM -FIR NO. 1 Fb = 975 PSI, Fv = 150 PSI 8. ALL PRESSURE -TREATED (P.T.) WOOD MEMBERS SPECIFIED ON THE PARTIAL FRAMING PLAN SHALL BE PRESSURE -TREATED WITH COPPER AZOLE CA -B (HEM -FIR ONLY), OR ALKALINE COPPER QUAT (ACQ-C FOR DOUGLAS -FIR, OR ACQ-D FOR HEM - FIR) PRESERVATIVES UNLESS OTHERWISE NOTED. AMMONIACAL COPPER ZINC ARSENATE (ACZA) PRESERVATIVE, OR OTHER PRESERVATIVES WITH AMMONIA CARRIERS, SHALL NOT BE USED. 9. SHEET METAL SCREWS SHALL CONFORM TO THE AMERICAN IRON AND STEEL INSTITUTE (A1SI) "SPECIFICATIONS FOR THE DESIGN OF COLD -FORMED STEEL STRUCTURAL MEMBERS". bD m a, 10. WOOD SCREWS SHALL CONFORM TO ANSI/ASME STANDARD B18,6.1. ]I. METAL STRAPS FOR ANCHORAGE OF MECHANICAL UNITS SHALL CONFORM TO ASTM A446 GRADE A WITH A MINIMUM YIELD STRESS OF 33 KIPS PER SQUARE INCH. 12. BOLTS SHALL CONFORM TO ASTM A-307. 13. CONNECT THE NEW UNIT TO THE WOOD SLEEPERS WITH FOUR (4) 18 GAGE x 2-1/2" WIDE GALVANIZED METAL STRAPS WITH TWO (2) 410 SHEET METAL SCREWS INTO THE UNIT AND TWO (2) #10 x 2" LONG WOOD SCREWS INTO THE WOOD SLEEPERS AS SHOWN ON THE PARTIAL ROOF FRAMING PLAN. CONNECT THE PRESSURE TREATED 4x6 WOOD SLEEPERS TO THE EXISTING ROOF FRAMING AS LOCATED ON THE PARTIAL ROOF FRAMING PLAN WITH (4) 5/16" DIAMETER GALVANIZED BOLTS. COUNTERSUNK THE BOLTS INTO THE WOOD SLEEPERS AND EMBED THE BOLTS A MINIMUM OF 3" INTO THE EXISTING 4x14 WOOD PURLINS. SEAL WOOD SLEEPERS AT EACH BOLT TO PREVENT THE INTRUSION OF WATER INTO THE STRUCTURE. WE 4- C-1 Moore PROJECT: ENGR: IL(Ifil-'o DATE: ENtz)-� (L3 Group SCALE: SHEET PROJECT DESCRIPTION: The project consists of the replacement of an existing rooftop mechanical unit. LOADS: LIVE 25 PSF DEAD Roofing and re -roof 5.0 1/2 Plywood sheathing 1.5 2x4 @ 24" o.c. 0.7 4x14 Q 8' o.c. 1.5 Insulation 1.0 MEP 2.0 Ceiling & Lights 2.0 Total Dead 13.7 DEAD + LIVE 38.7 PSF WIND 85 mph, Exposure B SEISMIC Latitude 47.483 Longitude -122.278 Site Class C to D WA DNR SDs = 0.996 EQUIPMENT Existing RTU New RTU Unit 338 615 Curb Wood Sleeper 38 -Z7 Total 378 pounds G qo pounds Dimensions 74"x47"x47" high Moore PROJECT: ENGR: KWM ;- Engineering ENDERS RTU DATE: 1/ 19/16 1! Group SCALE: SHEET Design Maps Summary Report ag lIQ S Design Maps Summary Report User -Specified Input Report Title Enders RTU Sat January 16, 2016 14:57:57 UTC Building Code Reference Document 2012 International Building Code (which utilizes USGS hazard data available in 2006) Site Coordinates 47.4831N, 122.2781W Site Soil Classification Site Class C - "Very Dense Soil and Soft Rock" Risk Category I/II/III t .1 ; 4t 1• Ui R6. 1 ( USGS-Provided Output Page 1 of 2 ! ssaquah ►nfion - �. H Ss = 1.493 g Sms = 1.493 g §,,s = 0.996 g S, = 0.559 g 5:,, = 0.727 g So, = 0.485 g For information on how the SS and S1 values above have been calculated from probabilistic (risk -targeted) and deterministic ground motions in the direction of maximum horizontal response, please return to the application and select the "2009 NEHRP" building code reference document. MCEa Response Spectrum 1.65 1.50 1.3` 1.20 1.05 im 0.90 M 0.!5 0.60 0.4` 1130 0.15 0.00 0.00 0.20 0.40 0.60 0.90 1.00 1.20 1.40 1.60 1.90 2.00 Period, T (sec) Design Response Spectrum 1.10 1.00 0.90 0.20 0.70 7 0.60 N 0.50 0, 40 0.30 0.20-- 0.10.- 0.00 .200.100.00 0.00 0.20 0.40 0.60 0.90 1.00 1.20 1,40 1,60 1.90 2.00 Period, T (sec) http://ehp 1-earthquake.cr. usgs.gov/designmaps/us/summary.php?template=minimal&latitu... 1/16/2016 i Ef i Qo �\ 1 i C1` M V) CE-) RTC, General Data Table 1 General Data Propeller Propeller Propeller q/ Model RTCO24C100B BTC030C100B BT0036CIDOB BT0036C3008 BTC038C400B Rated VOtts/PWHz 230/1/60 200/230/1/60 200/230/1/60 20D/230/3/60 4W/3/60 ARI hating' C/m @ 0.01n. w.g.- 1700 2300 2300 2300 Not Cooling Capacity 23000 29200 34000 34000 34000 Indoor Airflow (cfm) 800 ;000 1200 1200 1200 Power Input (kw) 2.66 3.61 4.07 4.07 407 EER/SEER' 8.66/9.50 8.10/9.15 e.36/9.75 1135/9.75 8.36/9.75 Noise Rating Number- 7.8 8.2 8.2 82 8.2 Outdoor Coll —'type Plate Fin Plate Fin Piste Fin Plate Fin Plate Fin Rows/FPI 3/15 4/16 4/15 4/15 4/16 Face Area (sq. ft.) 6.73 5.73 5.73 6.73 6.73 Tube -Size (in.) 3/8 3/8 3/8 3/8 3/e Indoor Coil —Type Plate An Plato Fin Plate Fin Plate Fin Plate Fin Rows/FPI 4/12 4/12 4/12 4/12 4/12 Face Area (sq. it) 3.44 3.44 3.44 344 3.44 Tube-Stze (in.) 3/8 3/8 3/8 3/8 3/8 Refrigerant Control Capillary Tube Expansion Valve Expansion Valve Expansion Valve Expansion Valve Drain Conn. Size (h) 3/4 NPT 3/4 NPT 3/4 NPT 3/4 NPT 3/4 NPT Outdoor Fan — Type Propeller Propeller Propeller Propeller Propeller No. Used / Dia (in.) 1/20 1/20 1/20 1/20 1/20 Type Drive / No. Speeds Direct / 1 01 MA / 1 Dirent / 1 Direct 11 Direct / 1 C/m @ 0.01n. w.g.- 1700 2300 2300 2300 23W No. Motors 1 1 1 1 1 Indoor Fan—Type Centrifugal Centrifugal Centrifugal CenlAfugal Centrifugal Din. xWldth(In.) 9x9 10x9 10x9 10x9 10x9 No. Used 1 1 1 1 1 Drive / Speeds (No.) Direct / 2 Direct / 2 Direct / 2 Direct / 2 Dired / 2 No, Motors 1 1 1 / 1 Filter— Furnished No No No No No Type Recommended HI Vel. J (No. / Size / ThIL) I/ 20x20 / 1 In. 1 / 20x2.5 11 in. 1 / 2040 /1 in. 1 / 20x30 % 1 In. 1 / 2Dx30 11 in. Refrigerant Charge 5 Los, 2 Oz. 7 Lbs. 0 Oz. 7 Lbs. 3 Oz, 7 Lbs. 3 Oz_ 7 Lbs. 3 Oz. Dimensions H/W/D H/W/D H/W/D H/W/D H/W/D Crated (in.) 3011/33%/46 3011/33%/46 3011/33%/46 30%/3311/46 30th/33%/46 Weight Shlodrm iibs.) / Net Ilbs.l 286 / 270 SO/290 354 1330 354/339 354 /338 ) NOTES 1. Rated In accordance whh ARI Standard 210. 2. Rated In somrdance wtih ARI Standard 270. a Standard Air-DryWI-Outdoor 4. Rated in accordanco whb OM test procedure V cvl_v� Performance Summary Far 3T Pkg HP-Horiz Project -Untitled/ 12/22/2015 Prepared By: 02:29PM Part Number:50TCQA04A2A6-OAOAO ARISEER: ......... .... _ ........... . ........... - -------- ----_-_------------- ... ....... ................ .--------- ----._..................... --13.40 Base Unit Dimensions UnitLength: ........................................... ....................... --- -...._..._............................... -.... _.._.... ................. 74.4 in UnitWidth: ............. . ...... .... .. ....-----....................--..... -- ------_....._.............................. - - .... .... .._.................. 46.8 in UnitHeight:_..._...---------._._......-.........._....----------- -._.,........-_..........._...---------........_..........33.4 in Operating Weight BaseUnit Weight ----------- -... -._..... _...................____ -----__._........................._...----------- ........... _.......... .505 lb Medium Static Option Belt Drive: ............ _.......... -- -----........... ._ ............................. -- ------------............................. -......_..10 Ib Accessories 5.5/6.0 kW 4601480-3-60, 4.2 kw 400-3-50 Volt Electric Heater..............._.__...______._._.__..___.._.............................._30 lb Standard Leak Horizontal EconoMi$er IV with solid-state controller ......... ...... _.-.—.-__._......._ ........ ................70 lb Total Operating Weight: ............ . . . . . .. ............. .......... 616 Ib Unit UnitVoltage -Phase -Hertz: .................. ............ - ....- ---- ------ --- -..._.... ...... _....... ....... ..................... .._ ...................... _..460-3-60 Air Discharge: .-._-_..... ..................... ............._......----- ---- ------......... ...................... ........ ......_....- -Horizontal FanDrive Type: ............................ ................. ... ... ... ............................. ...... _... ....... ........ Belt ActualAirflow: .................... ..... ............ .......... .. . ..... __ ............ ............ ............... _._ ...... -------------.1200 CFM SiteAltitude:..._._............................................_._.._........................ - ----- ---...__.._...... ..................... ................................ ------------ -0 It Cooling Performance CondenserEntering Air D8: ................. . .......... ........................................ ..... ------ ---------- --....._....... _ ............................ ..._....96.0 F EvaporatorEntering Air DB: ........................................................................... . ............. __ - ---•--------._....._...............................80.0 F EvaporatorEntering Air W13: ...... ._..........................._.....................................................- - - - ------ ..... _.................. ......67.0 F EnteringAir Enthalpy:_..... ------....._........._....._ ...... ............................................................... _... _............ __..__._....._._....._ ..... 31.44 BTU/Ib EvaporatorLeaving Air DB: .............. ............................. ............. ............ .... . .... __ ...... ...... ........ ........ .. ........ ..... ... 57.7 F EvaporatorLeaving Air WB:-.-_ .......... _..........._............................................. _........ -- ---- - -- -- - --- ----- --- .._...57.1 F EvaporatorLeaving Air Enthalpy:---.._ ... _....................... _....................................... ........................................ -...... -.................... 24.44 BTU/Ib Gross Cooling Capacity:.._-___. ........... --- -- --.... - ----..........__.................................. _............ .. 37.80 MBH GrossSensible Capacity:._...... -- - ---.._...._......_ ----_...---................................. _.................... _...... 28.90 MBH Compressor Power Input-----------------.----._—____ ....... ................................................. __.—_._._3.00 kW CoilBypass Factor: ..... ..... _._.. ---- — -- ----------------........_........._.._.._..................................... -..._.0.036 Heating Performance OutdoorAmbient Temperature: ............. . ..................... ..... ...................-------.._.._.__......_.................................._...47.0 F EnteringAir Indoor Cort DB:_..---....---...--_-.—..----------- ..... -..... .._...................................._....... ._.------70.0 F Leaving Air Indoor Coil D13: ................ ....... ....... ..... . .............. ..... ...... .... ...... F TotalHeating Capacity : ......................................... ................................ - ................... -.---•------........_............._. ......35.40 MBH IntegratedHeating Capacity:....._ ................ ............ _..................... ................ ................ .... -...... ....... ........................................... ..... 35.40 MBH HealingPower Input: ........ ...... ------.... -_............._........................... ............... ............. -..... .... ---- ........... ......... ................. _.......2.84 kW HSPF:--....--....___...- -..._...._............................................_.........._................_.........---...._................................................. ... .......... 7.7 ElectricHeating Capacity: .................__.._._..................._......_............._........_..-----._... _......_.................._.......... ........ _5.50 kW UnitLeaving Air Temp_.__....__...._..----•-•.............................................................-- ...._...._...._....................................111.8 F Supply Fan ExternalStatic Pressure:........_ ...... ............. _........ __ ........__.......---------... ......... ......-.............. _........_.......... .... --..__.............0.60 in wg Options / Accessories Static Pressure ElectricHeaters:_--_._._.........................................................-...........---.... ... ....... ......... ... ......................................0.07 in wg Economizer, •---__..._......................._......_......................... __. _......._................. .........____ -...........0.06 in wg Total Application Static (ESP + Unit Opts/Acc.):....................................................-.--.......--------...-------•----._........_.._...............0.72 in wg FanRPM: ............ ........................ . .... ........... . ...... __ ................... __. . ....... . .. ................................ ...... . . . _................. 912 FanPower......--- ..._ ... _....... ............ ................_....-•------....------ ----_...._...-............... ._.._....................... ................ -9.53 BHP NOTE: ......... _._ . ...-----...... -.-........................ ..... _...................... _........................ Selected IFM RPM Range: 819 -1251 Electrical Data VoltageRange:_ ...............-------------------- ------.._--- .... ........._...................... _...-- - .....---- ..__414 - 606 Packaged Rooftop Builder 1.39v Page 6 of 9 .c O X 2 w�e I I i Ids �j S tl Yw E qi- X 2 w�e I I i Ids N O CL Z CD Y h - M C tC L t� 0 N N C� C t t w .2— IL a x a 0 V 0 lio I"10 1 If AX a= e i7 ri'l..f c-__ r t r `•' � '/L�," �o-l� 'l; ��;=,fir', ' J;� r'�� 7 /�, Moore tPROJECT: _ ENGR: )L(,t_i �v I f ( �= 1 l '.- DATE: engineering - ; Group SCALE: SHEET ,/! —V o 171' Moore PROJECT:ENGR: Engineering DATE: Group SCALE: SHEET- PERMIT COORD COPY PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: M16-0019 PROJECT NAME: ENDERS SITE ADDRESS: 4495 S 134TH ST X Original Plan Submittal Response to Correction Letter # DEPARTMENTS: As Atk-,, )-� Building Division IN DATE: 02/03/16 Revision # before Permit Issued Revision # after Permit Issued AY\ N/)g- 0'-")-zA� Fire Prevention IN Planning Division ❑ Public Works ❑ Structural ❑ Permit Coordinator ❑ PRELIMINARY REVIEW: DATE: 02/02/16 Not Applicable ❑ Structural Review Required ❑ (no approval/review required) REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: DUE DATE: 03/01/16 Approved In Corrections Required ❑ (corrections entered in Reviews) Notation: REVIEWER'S INITIALS: Approved with Conditions Denied ❑ (ie: Zoning Issues) DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ PIng ❑ PW ❑ Staff Initials: 12/18/2013 COMFORT MECHANICAL INC - Washington Mate Department of Labor & Industries Page 1 of 2 Home Espanol. Contact Search L&I — I A-7. Index. Help MV Secure I,SI. Safety & Health Claims & Insurance Workplace Rights Trades & Licensing COMFORT MECHANICAL INC Owner or tradesperson 3202 C ST NE AUBURN, WA98002 Principals 425-251.9840 JACKSON, SHIRLEY A, PRESIDENT KING County JACKSON, HERB J, VICE PRESIDENT Doing business as COMFORT MECHANICAL INC WA UBI No. Business type 601 954 041 Corporation Governing persons HERB J JACKSON SHIRLEY A JACKSON; License Verify the contractor's active registration / license / certification (depending on trade) and any past violations. Construction Contractor Active. ....._................_...................................._........ Meets current requirements. License specialties HeatingNent/Air-Conditioning and Refrig (HVAC/R) License no. COMFOM1015LA Effective — expiration 06101/1999— 04/25/2016 Bond ................ $1,000,000.00 Lexon Ins Co $6,000.00 Bond account no. 9815017 Effective date Received by L&I Effective date 06/04/2012 0610112012 Expiration date Until Canceled Bond history Insurance Continental Western Ins Co $1,000,000.00 Policy no. CWP6015115 Received by L&I Effective date 05/27/2015 06/01/2015 Expiration date 06/01/2016 Insurance history https://secure.Ini,wa.gov/verify/Detail.aspx?UBI=601954041&LIC=COMFOMIO15LA&SAW= 2/23/2016 'Panel r Number .___. •----- 261320-0084' Date .1/20!2016 Name ` . REALTY ASSOCIATES FUND X LP Replace (1) packaged rooftop unit.with new like unit. Include documentation requiring compliance with commissioning requirements, Section C408 Site Address 4495 S 134TH PL 98168 Equipment SChedUleS FOSTORIA GARDEN TRS LOT 1 OF TUKWILA SHORT PLAT NO 79-26-SS.RECORDIING NO 8004240503 Cooling Eq ui ment Schedule SD PLAT DAF = TR 16 & 17.FOSTORIA GARDENS TRS LESS POR CONV TO CO AF #5721821 & AF 1 #1006280 & TO STATE AF #5712570 FOR HWY - MORE PRTLY DAF - POR SD LOTS BEG SW COR LOT ' 16 TH S,45-44-45 E 172.63 FT ALG NELY MGN SO 135TH ST THS 66-16-10 E 104:10 FT ALG SD MGN 1 OF S 135TH.ST TH N4144-57 E 827.31. FT ALG SD SELY LN OF LOT 16 TO NELY COR SD LOT ,16 TH N Legal 48-15-03 W 61.40 FT ALG NELY LN SD LOT 16 TH S 41-44-57 W 19.50 FT TH NWLY 68.65 FT ALG ARC GSP Carrier CRV TO RGT RAD 185.80 FT RAD PT N 41=44-57 E'THRU C/A 21-10-15, TH N 27-04-46 W 19.26 FT TO 13.4 NELY LN SD LOT 16TH N48 -15-03W 125 FT ALG SD NELY LN LOT 16 TO COR COMMON TO LOTS 16 Econo N'. & 17 TH CONT. 1.15.97 FT ALG NELY LN LOT 17 TH S 89-57-57 W 208.18 FT ALG SLY MGN RELOCATED SO 133RD ST TO NWLY LN LOT 17 TH S 4.1-44-57 W 521 FT ALG SD NWLY LN OF LOT 17 TO NLY MGN S 135TH.ST THS 29-18-21 E 91.43 FT ALG SD NELY MGN S 135TH ST TH S 05-51- 2 W.196.92 FT ALG _. ELY MGN OF SD S 135 TH ST. TH S. 45-44-45 E 69.35 FT ALG NELY MGN SD S .135TIH ST TO POB ' - 2012 Washin ton State Ener Code Com liance Forms for Commercial GroUD R1 and > 3 story R2 & R3.3 Revised June lois Project Info Project Address Ender' 4495 S 1234th PL Tukwila, WA 98168 Applicant Name: JESSE CHUTICH Applicant Address:. 3202 C ST NE, AUBURN, WA 98002 Applicant Phone: 425.281-9840 Date .1/20!2016 For Building Dept. Use Project Description Briefly describe mechanical system type and features. Includes Plans Replace (1) packaged rooftop unit.with new like unit. Include documentation requiring compliance with commissioning requirements, Section C408 Compliance Option @) Simple System Q Complex System O System Analysis Equipment SChedUleS The following information is required to be Incorporated with the mechanical equipmen schedules on the plans. For projects without plans, fill in the required Information below Cooling Eq ui ment Schedule Equip. ID Equip Type Brand Name' Capacity- OSA CFM Model No.' Btu/h or Econo? SEER or EER IPLV3 Econmizer Heat Option or Recovery Exc 5 Y/N RTU -1 GSP Carrier 50TCQA04A2A6 3800.0 Econo 13.4 n/a Econo N'. Heating Equipment Schedule Equip. Equip I ID Type Brand Name' i Capacity- OSA cfm Model No.' Btu/h or Econo? - Input Btuh Heat Output Btuh Efficiencyi Recovery YIN RTU -1 GSP Carrier 50TCQA04A2A6 35,000 Econo 35000 HSPF:7..7 N Fan Equipment Schedule Equip. Equip ID Type Brand Name' Model No.. CFM SPI HP/BHP Flow Controls Location of Service Service Water Heating Equipment Schedule Equip. Equip ID Type Brand Name' Model Not Input Capacity Sub- Category EFS Location of Service - 9 r 2 3 If r a CO PF Combustion Efficient or AFUE, as c If available. As tested according to Table C403.2.3(1)A thru C403.2.3(8). required. P, HS y e applicable. 5 Flow control types: variable air volume (VAV), constant, volume (CV), or variable speed (VS). Economizer exception number per Simple Systems C403.3.1 or Complex Systems C403.4.1. 7 Efficiency Factor per Table C404.2 RLE COPY Alft Da ,,I Plane ravl8w approval is subject to errors and orni3sioriy. Approval of consiruction documents does riot authorize the violation of any adopted code or ordinance. Recoipt of approved Field Copy and conditions is acknowledged: By: Date: City of Tukwila BUILDING DIVISION r-FLh,R,AT E PEl`MI T i .zOUiR ED FOR: 0 mechanical �'----.. L%i'�jpct,-�ca1 REWEWED FOR 'Rtumbing CODE CO PL.IANCE was Piping PPO�� �lty of TukwilaFEB 8 2016 SD't DAIG DIVISION J City of Tal HVAC Equipment Schedule (Existing) BUILDING DIVISION # Brand Model Ton. Total CFM Cap. Heat Cap. Cool SEER. Weight Sound(bels). Location RTU -1 Carrier 50TCQA04A2 3 1,200 35,000 38,000 13.4. 615 77 Roof REVISIONS R C T VEE CITY QFTU,rK`A`!LA FEB 0 1 2016 PERMIT CENTER.