Loading...
HomeMy WebLinkAboutPermit M16-0021 - BEST BUY - DUCT WORK AND GRILLES / DIFFUSERSBEST BUY 17364 SOUTHCENTER PKWY M16-0021 City of Tukwila • Department of Community Development 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-438-9350 Web site: http://www.TukwilaWA.Rov MECHANICAL PERMIT Parcel No: 2623049110 Permit Number: M16-0021 Address: 17364 SOUTHCENTER PKWY Issue Date: 2/23/2016 Permit Expires On: 8/21/2016 Project Name: BEST BUY Owner: 2012 Name: KIR TUKWILA 050 LLC Address: 3333 NEW HYDE PARK RD #100 C/O WA Cities Electrical Code: KIMCO REALTY CORP, PO BOX 5020 International Mechanical Code Edition: NEW HYDE PK, WA, 11042 Contact Person: 2014 Name: ALEX BURKHART Address: 727 S KENYON ST, SEATTLE, WA, International Fuel Gas Code: 98108 Contractor: Name: EVERGREEN REFRIGERATION LLC Address: 727 S KENYON ST, SEATTLE, WA, Permit Center Authorized Signature: 98108 License No: EVERGRL954R2 Lender: Name: Address: DESCRIPTION OF WORK: Valuation of Work: $0.00 Type of Work: Fuel type: Phone: (206) 763-1744 Phone: (206) 763-1744 Expiration Date: 1/6/2018 Fees Collected: $298.16 Electrical Service Provided by: PUGET SOUND ENERGY Water District: HIGHLINE,TUKWILA Sewer District: TUKWILA SEWER SERVICE Current Codes adopted by the City of Tukwila: International Building Code Edition: 2012 National Electrical Code: 2014 International Residential Code Edition: 2012 WA Cities Electrical Code: 2014 International Mechanical Code Edition: 2012 WAC 296-4613: 2014 Uniform Plumbing Code Edition: 2012 WA State Energy Code: 2012 International Fuel Gas Code: 2012 ` t Permit Center Authorized Signature: Date: I hearby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this development permit and agree to the conditions attached to this permit. a Signature: -Date: 2� v� Print Name:A`o'—"L v � This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: Work shall be installed in accordance with the approved construction documents, and any changes made during construction that are not in accordance with the approved construction documents shall be resubmitted for approval. 2: All permits, inspection record card and approved construction documents shall be kept at the site of work and shall be open to inspection by the Building Inspector until final inspection approval is granted. 3: Readily accessible access to roof mounted equipment is required. 4: All construction shall be done in conformance with the Washington State Building Code and the Washington State Energy Code. 5: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of this requirement. 6: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center. 7: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 8: ***MECHANICAL PERMIT CONDITIONS*** 9: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431-3670). 10: Manufacturers installation instructions shall be available on the job site at the time of inspection. PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 1800 MECHANICAL FINAL 0701 ROUGH -IN MECHANICAL CITY OF TUKW. Community Development Department Pennit Center • 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www`TukwilaWA.gov SITE LOCATION Mechanical Permit No. Project No. Date Application Accepted: 2 Date Application Expires: (For office use onlv) MECHANICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **please print** King Co Assessor's Tax No.: Site Address: �� (may Su khethJ� P� , Suite Number: Floor: Tenant Name: New .......... ❑ New Tenant: ❑ .....Yes ©-.-Vo PROPERTY OWNER Name: ki i �/Kwt 1750 L, . Address: .3 ��� �%a..✓ & Pl.i�- �.� too City: Nom✓ 14, galt State: CONTACT PERSON - person receiving all project communication Name: /,,� Address: -) vi 5L V -Hl Kevtgo,\ S-� City:�1N,. State: \ /, Zip: Phone:2,,(- "3- Mqq Fax: SCK-763-231$�l Email: iQx 6(2 �tt+nhvac �Go�n MECHANICAL CONTRACTOR INFORMATION Company Name: V1 R6 � n � 1 &,r! L til Address: 72,1 Sw4-h Went tan Sf , City: State: Zip: It t(A Phone: U 6 -163 - 1-144 Fax: ?/D6 --t63- 231q Contr Reg No.: V EKGg �,q$y p,Exp Date: 1 14 lit Tukwila Business License No.: B us , O1 qu ?-1 Valuation of project (contractor's bid price): S 1 ( 2-t •� Describe the scope of work in detail: -'Fvt547vU,L, lbti t d 1, a� arc llrs c�� �Sc\r5 Use: Residential: New .......... ❑ Replacement ........ ❑ Commercial: New .......... ❑ Replacement ........ ❑ Fuel Type: Electric..... ❑ Gas ....... ❑ Other:_ H:\Applications\Forms-Applications On Line\2016 Applications\Mechanical Permit Application Revised 1-4-16.docx Revised: January 2016 Page I of bh Indicate type of mechanical work being installed and the quantity below: Unit Type Qty Furnace <100k btu Residential, Nighttime Furnace >I 00k btu Industrial Floor furnace 55 dB(A) Suspended/wall/floor mounted heater 57 dB(A) Appliance vent Commercial Repair or addition to heat/refrig/cooling system 47 dB(A) Air handling unit <10,000 cfm 65 dB(A) Unit Type Qty Air handling unit 210,000 cfm Residential, Nighttime Evaporator cooler Industrial Ventilation fan connected to single duct 55 dB(A) Ventilation system 57 dB(A) Hood and duct Commercial Incinerator — domestic 47 dB(A) Incinerator — comm/industrial 65 dB(A) Unit Type Qty Fire damper Residential, Nighttime Diffuser Industrial Thermostat 55 dB(A) Wood/gas stove 57 dB(A) Emergency enerator Commercial Other mechanical equipment 47 dB(A) 60 dB(A) 65 dB(A) Boiler/Compressor Qty 0-3 hp/100,000 btu 3-15 h /500,000 btu 15-30 hp/1,000,000 btu 30-50 hp/1,750,000 btu 50+hp/1,750,000 btu Noise: Mechanical units need to be in compliance with the Tukwila Noise Code. Maximum permissible sound levels are based on from where the sound is created and where the sound is heard. Additionally, if sound can be heard from within a house at night in a residential zone it may not be allowed. For more details, see TMC 8.22 District of Sound Producing Source District of Receiving Property Residential, Daytime* Residential, Nighttime Commercial Industrial Residential 55 dB(A) 45 dB(A) 57 dB(A) 60 dB(A) Commercial 57 dB(A) 47 dB(A) 60 dB(A) 65 dB(A) Industrial 60 dB(A) 50 dB(A) 65 dB(A) 1 70 dB(A) *Daytime means 7AM-1 OPM, Monday through Friday and 8AM-1 OPM, Saturday, Sunday and State -recognized holidays. A few sounds are exempt from the noise code, including: Warning devices; Construction and property maintenance during the daytime hours (lam -1 Opm); Testing of backup generators during the day. PERMIT APPLICATION NOTES - Value of construction — in all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the permit center to comply with current fee schedules. Expiration of plan review — applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The building official may grant one extension of time for additional periods not to exceed 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). 1 HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR AUTHORIZED AGENT: Signature: Date: j Print Name:A_QI�Wwwk_ Day Telephone: — -1,6 Mailing Address: Z� Sy I/�G►��Ot^ 5'r- < l 0 - city State Zip H:\Applications\Forms-Applications On l-ine\2016 ApplicationsWechanical Permit Application Revised 1-4-16.docx Revised: January 2016 Page 2 of 2 bh DESCRIPTIONS ACCOUNT QUANTITY PAID PermitTRAK $366.41 EL16-0105 Address: 17364 SOUTHCENTER PKWY Apn: 2623049110 $68.25 ELECTRICAL $65.00 PERMIT FEE MULTI-FAM/COMM R000.322.101.00.00 0.00 $65.00 TECHNOLOGY FEE $3.25 TECHNOLOGY FEE R000.322.900.04.00 0.00 $3.25 M16-0021 Address: 17364 SOUTHCENTER PKWY Apn: 2623049110 $298.16 MECHANICAL $286.69 PERMIT ISSUANCE BASE FEE R000.322.100.00.00 0.00 $32.50 PERMIT FEE R000.322.100.00.00 0.00 $196.85 PLAN CHECK FEE R000.322.102.00.00 0.00 $57.34 TECHNOLOGY FEE $11.47 TECHNOLOGY FEE R000.322.900.04.00 TOTAL FEES PAID BY RECEIPT: R7586 0.00 $11.47 $366.41 Date Paid: Wednesday, February 03, 2016 Paid By: EVERGREEN REFR Pay Method: CHECK 007728 Printed: Wednesday, February 03, 2016 9:31 AM 1 of 1 OC N SYSTEMS INSPECTION RECORD Retain a copy with permit b l PECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Pr ect: Type ofpinssp9_ction: Address. Date Called: Special Instructions: ,,f¢4 Date d: r — - �� p.m. Requester: Phone No: REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call. to schedule reinspection. K INSPECTION RECORD y Retain a copy with permit I IN&HICTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project: Type of Inspection, Address`. 6' Date Called:. Special Instructions: Date Wanted: a.m. p.m. Reque ter: Phone No: FlApproved per applicable codes. EI Corrections required prior to approval. Inspector: Date: REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Cat[ to schedule reinspection INSPECTION RECORD Retain a copy with permit v�ad Z� ECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project: TyI)A of Inspection: ti :� ✓� 1 Address: � � Date Cal' d: Special Instructions: Date Wanted: a.m. i---- p.m. Requester: a6F, V1kd Phtne o : ,inspector: Date: `/ q ` I ❑ REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be . paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. PERMIT COORD COPY PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: M16-0021 DATE: 02/04/16 PROJECT NAME: BEST BUY SITE ADDRESS: 17364 SOUTHCENTER PKWY X Original Plan Submittal Revision # before Permit Issued Response to Correction Letter # Revision # after Permit Issued DEPARTMENTS: As &(, Building Division Public Works ❑ PRELIMINARY REVIEW: Not Applicable ❑ (no approval/review required) REVIEWER'S INITIALS: APPROVALS OR CORRECTIONS: Approved ❑ Corrections Required ❑ (corrections entered in Reviews) Notation: REVIEWER'S INITIALS: tkf�- D� Fire Prevention Structural ❑ Planning Division ❑ Permit Coordinator ❑ DATE: 02/04/16 Structural Review Required ❑ DATE: DUE DATE: 03/04/16 Approved with Conditions 5a", Denied ❑ (ie: Zoning Issues) DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: 12/18/2013 EVERGREEN REFRIGERATION LLC Heine ° Espanol Contact Safety & Health Claims & Insurance 001014 Washington State Department of "Labor & Industries EVERGREEN REFRIGERATION LLC Owner or tradesperson 727 S KENYON ST SEATTLE, WA98108 Principals 206-763-1744 PATTON, RODGER, PARTNER/MEMBER KING County PATTON, MATTHEW, PARTNER/MEMBER Patton, Adam, PARTNER/MEMBER Patton, Douglas, PARTNER/MEMBER EVERGREEN REFRIGERATION LLC, PARTNER/MEMBER PATTON, DAVID, PARTNER/MEMBER (End: 01/21/2014) Doing business as EVERGREEN REFRIGERATION LLC WA UBI No. Business type 602 512 953 Limited Liability Company Governing persons DAVID A PATTON MATTHEW PATTON; RODGER PATTON; License Page 1 of 3 Search L&I A -I Ind( Workplace Rights Verify the contractor's active registration / license / certification (depending on trade) and any past violations. Construction_Contractor. Active. Meets current requirements. License specialties GENERAL License no. EVERGRL954R2 Effective — expiration 01/06/2006— 01/06/2018 https:Hsecure.Ini.wa.gov/verify/Detail.aspx?UBI=602512953&LIC=EVERGRL954R2&SAW= 2/19/2016 MECHANICAL ABBREVIATIONS A.F.F. ABOVE FINISHED FLOOR ARCH ARCHITECT BTU BRITISH THERMAL UNIT CFH CUBIC FEET PER HOUR CFM CUBIC FEET PER MINUTE CL CENTER LINE CO CLEAN OUT CONTR CONTRACTOR CP CONDENSATE PUMP CW COLD WATER DIA DIAMETER DIFF DIFFUSER .DMPR DAMPER DN DOWN DR DRAIN DWG DRAWING EAT ENTERING AIR TEMPERATURE EWT ENTERING WATER TEMPERATURE EXH EXHAUST F FAHRENHEIT FC FAN COIL FCO FLOOR CLEAN OUT ` FD FIRE DAMPER OR FLOOR DRAIN : FLR FLOOR FLEX FLEXIBLE FT FEET OR FOOT GA GAUGE GAL GALLON GPH GALLONS PER HOUR GPM GALLONS. PER MINUTE GR GRILLE HTG HEATING HTR HEATER HVAC HEATING, VENTILATING AND AIR CONDITIONING HW HOT WATER INSUL INSULATION KW KILOWATT LAT LEAVING AIR TEMPERATURE LWT LEAVING WATER TEMPERATURE MBH BTU PER HOUR (THOUSANDS) NC NOISE CRITERIA OR NORMALLY CLOSED NEG NEGATIVE NIC NOT IN CONTRACT NTS NOT TO SCALE OA OUTSIDE AIR OBD OPPOSED BLADE DAMPER PLBG PLUMBING PVC POLY VINYL CHLORIDE RA RETURN AIR. RD ROOF DRAIN RECIRC RECIRCULATING REG REGISTER RET RETURN RH RELATIVE HUMIDITY RHT REHEAT RHC REHEAT COIL RHW RECIRCULATED HOT WATER RM ROOM RP RADIANT PANEL RPM REVOLUTIONS PER MINUTE SA SUPPLY AIR SAN SANITARY SID SMOKE DAMPER SP STATIC PRESSURE SPECS SPECIFICATIONS SUP SUPPLY SQ SQUARE TEMP TEMPERATURE TONS TONS OF REFRIGERATION T -STAT THERMOSTAT TYP TYPICAL V SANITARY VENT VAV VARIABLE AIR VOLUME VD VOLUME DAMPER VOL VOLUME W SANITARY WASTE W/ WITH W/O WITHOUT . WCO WALL CLEAN OUT WTR WATER 22"0 18"01�4"0 10"0 iQl \ . OI Ocov 0I01 ✓/ ; 14 1 ��I/J 1 v �V.. v�-i Z N O M O - = 001 1 ' mi r j `°' ID' ; 0 i 01 = o 0 W ICI V�' j P1 1 V J^ V ♦\ 1'i I I I I a 1 I�\I i i NI I �W �� 0 Ifs zR ZZe,� E. R—t-71 (q r (� Z NW .-to® 1 4 I I I I p N1 w OZ_ C 02< OJ Wj V3ZLai Z a SPECIFICATION DATA DIFFUSER DIMENSIONAL DATA RTU SIZE (TONS) AES DIFFUSER MODEL N0: THROW CFM A B 12-1/2 ADB -1-12 66' 5000 30" 13", SCALE: N.T.S. AL DUCT VOLUME DAMPER SUPPLY GRILLE SUPPLY GRILLE CONNECTION (30° SCALE: N.T.S. I� 1 VO a�ZOjC� oo�0.if W L ; 0 E Lf 3 &ScitJ![.r to o � N 00 CA O N U - !n LL U SALES _ o o !2 FLOOR m m 112 _ a�' c iu+. L a'X - - _ - - - ....-- - - -- a �- - a IONS m w a c O TSif _ � %s O c Z2s sh?t b mads t© tl Q �, 2 o0 a 16'vork vi th^csL F►icr approval t T �'�} ila BIlilCili2 JOB #: 416752-040 I NOTE: rzeziSiQMSYdiliregU, aaDll r�©tom Stil}ulin8i SQ: FT. CALCS acid :yind lda ad taonal Plan review fm. RETAIL: 38,966 SF HVAC PARTIAL PLAN OFFICES& %�° 1 — n ASSEMBLY: 8/ 6 SF 1/411 - 1-0 STORAGE/ REMAINING: 4,890 V 1 Perm -it no.s00�0. INSTALL: } . M53 SF Plan review approval is gut to errors : of IsslonS. TOTAL 45,885 SF Approval of consiruciion documents does not authorize REMODEL the violation of any adopted code Or Qrdinance. Raceipt AREA: 6, 767 SF CONCEPT: .45K CS1.9 CONCEPT DATE: XX.XX.XX G.O. -21 FIXTURE REL XX.XX.XX G.O. -13 FINAL REL . XX.XX.XX . PROTOTYPE DATE: XX.XX.XX STORE NUMBER: 0447 HVAC PARTIAL PLAN 1/4" = 1--0" DIFFUSER, GRILLE & REGISTER SCHEDULE MECHANICAL SYMBOLS LEGEND MOUNTING VINTAGE CFM ANNOTATION MODEL NO. VOLTAGE & PHASE DUCTWORK O.A. TYPE A -8"O a—(SQUARE SA DIFFUSER: INDICATES NECK SIZE) 350, (LINEAR SA DIFFUSER: INDICATES DIFF. LENGTH) (RETURN/EXHAUST/TRANSFER GRILLES REGISTERS: INDICATES UNIT SIZE) \,--CFM �— TYPEDESCRIPTION SUPPLY AIR TRANE EXHAUST DUCT UP, NEGATIVE PRESSURE �-- RETURN AIR EXHAUST AIR, MODEL NO. SUPPLY DUCT DOWN, POSITIVE PRESSURE STANDARD BRANCH, NO SPLITTER - SUPPLY FLOW TO RIGHT - RETURN/EXHAUST FLOW TO LEFT S,-� RETURN DUCT DOWN; NEGATIVE PRESSURE SEE ELEC. EXISTING RTU -13 BELLMOUTH WITH BALANCING DAMPER S--® EXHAUST DUCT DOWN, NEGATIVE PRESSURE X �-- X e DETAIL NUMBER SHEET NUMBER E FLEXIBLE- DUCT DROP BOX SUPPLY DIFFUSER/REGISTER BLANKOFF INDICATED DARK X -a-- X �--SHEET SECTION NUMBER NUMBER AES INDUSTRIES ADB TURNING VANES H RETURN GRILLE/REGISTER SURFACE SIZE PER PLAN MANUAL VOLUME DAMPER X X �-- EQUIPMENT DESIGNATION EQUIPMENT NUMBERMD TITUS ® 1,2 EXHAUST GRILLE/REGISTER MOTORIZED DAMPER POINT OF CONNECTION, ® NEW TO EXISTING LINEAR DIFFUSER ® POINT OF DISCONNECT MECK NOTES FD FIRE DAMPER &ACCESS PANEL �''�j' CONCENTRIC DUCT TRANSITION A. OPPOSED BLADE DAMPER CONTROLS SD4, SMOKE DAMPER & ACCESS PANEL S ECCENTRIC DUCT TRANSITION fso SMOKE DETECTOR RE WED FOR FSD COMBINATION FIRE/SMOKE DAMPER & ACCESS PANEL - RECTANGULAR -TO -ROUND DUCT TRANSITION Os SPACE TEMPERATURE SENSOR ® CARBON MONOXIDE SENSOR S� -i SUPPLY GRILLE OR REGISTER EXISTING DUCT TO REMAIN Q THERMOSTAT G CARBON DIOXIDE SENSOR S—� A, �y�,. RETURN OR EXHAUST GRILLE OR REGISTER EXISTING DUCT TO BE REMOVED O NITROSOXIDE SENSOR Q TWIST TIMER S----® SUPPLY DUCT UP, POSITIVE PRESSURE VAV BOX 5--� RETURN DUCT UP, NEGATIVE PRESSURE }—S VAV BOX W/ REHEAT COIL I� 1 VO a�ZOjC� oo�0.if W L ; 0 E Lf 3 &ScitJ![.r to o � N 00 CA O N U - !n LL U SALES _ o o !2 FLOOR m m 112 _ a�' c iu+. L a'X - - _ - - - ....-- - - -- a �- - a IONS m w a c O TSif _ � %s O c Z2s sh?t b mads t© tl Q �, 2 o0 a 16'vork vi th^csL F►icr approval t T �'�} ila BIlilCili2 JOB #: 416752-040 I NOTE: rzeziSiQMSYdiliregU, aaDll r�©tom Stil}ulin8i SQ: FT. CALCS acid :yind lda ad taonal Plan review fm. RETAIL: 38,966 SF HVAC PARTIAL PLAN OFFICES& %�° 1 — n ASSEMBLY: 8/ 6 SF 1/411 - 1-0 STORAGE/ REMAINING: 4,890 V 1 Perm -it no.s00�0. INSTALL: } . M53 SF Plan review approval is gut to errors : of IsslonS. TOTAL 45,885 SF Approval of consiruciion documents does not authorize REMODEL the violation of any adopted code Or Qrdinance. Raceipt AREA: 6, 767 SF CONCEPT: .45K CS1.9 CONCEPT DATE: XX.XX.XX G.O. -21 FIXTURE REL XX.XX.XX G.O. -13 FINAL REL . XX.XX.XX . PROTOTYPE DATE: XX.XX.XX STORE NUMBER: 0447 HVAC PARTIAL PLAN 1/4" = 1--0" DIFFUSER, GRILLE & REGISTER SCHEDULE EQUIP. ELECTRICAL MOUNTING VINTAGE CFM MANUF. MODEL NO. VOLTAGE & PHASE TOTAL O.A. LETTER SERVICE TYPEDESCRIPTION 965 TRANE ACCESSORIES FINISH MANUF. MODEL NO. MECH. NOTES 100 TRANE YCC018 SEE ELEC. EXISTING RTU -13 2000 600 100 TRANE YCC018 E SUPPLY DUCT DROP BOX _ B WHITE AES INDUSTRIES ADB 3,4 H SUPPLY SURFACE SIZE PER PLAN A WHITE : TITUS 30ORL 1,2 MECK NOTES ACCESSORIES 1. APPROVED EQUAL: TUTTLE BAILEY, CARNES, A. OPPOSED BLADE DAMPER PRICE 2. DOUBLE DEFLECTION, FRONT BLADES B. REFER TO DETAIL 3/M2.0 PARALLEL TO LONG DIMENSION, ALL BLADES RE WED FOR ADJUSTABLE, 3/4" SPACING. ILI) � 3. NO SUBSTITUTIONS CODE COMPLIANCE. 4. REFER TO DETAIL 3/M2.0 FOR MORE INFORMATION � EXISTING ROOFTOP UNIT SCHEDULE GENERAL MECHANICAL ELECTRICAL EQUIP. NO. VINTAGE CFM MANUF. MODEL NO. VOLTAGE & PHASE TOTAL O.A. EXISTING RTU -3 2000 5000 965 TRANE YCD151 SEE ELEC. EXISTING RTU -12 2000 600 100 TRANE YCC018 SEE ELEC. EXISTING RTU -13 2000 600 100 TRANE YCC018 SEE ELEC. BALANCE EXISTING UNIT FOR SCHEDULED AIRFLOW. VERIFY WITH BEST. BUY CONSTRUCTION PROJECT MANAGER THAT UNIT HAS BEEN SERVICED AND REPAIRED PRIOR TO BALANCING WORK. iUK- GENERAL NOTES: City ofTuk ( BUILDING DIVISION 1. MECHANICAL CONTRACTOR SHALL ENSURE CONTINUOUS OPERATION OF BID & PERMIT SET EXISTING HVAC EQUIPMENT AND ASSOCIATED EMS CONTROLS 12-04-15 THE CONSTRUCTION PERIOD. REV DATE a 1 1 p f.t.:f�Yr...H- FEB 4 3 201 PERN-11T CENTER. ENLARGED HVAC PLAN nnin VESTIBULE 101 co 3 CO _ W O RE WED FOR ILI) � CODE COMPLIANCE. APP OVER � FEB 18 2011 r. iUK- GENERAL NOTES: City ofTuk ( BUILDING DIVISION 1. MECHANICAL CONTRACTOR SHALL ENSURE CONTINUOUS OPERATION OF BID & PERMIT SET EXISTING HVAC EQUIPMENT AND ASSOCIATED EMS CONTROLS 12-04-15 THE CONSTRUCTION PERIOD. REV DATE a 1 1 p f.t.:f�Yr...H- FEB 4 3 201 PERN-11T CENTER. ENLARGED HVAC PLAN nnin