Loading...
HomeMy WebLinkAboutPermit M16-0023 - TRITON - UNIT HEATERTRITON 530 INDUSTRY DR M16-0023 City of Tukwila • Department of Community Development + 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-438-9350 Web site: http://www.TukwilaWA.gov MECHANICAL PERMIT Parcel No: 0223400010 Permit Number: M16-0023 Address: 530 INDUSTRY DR Issue Date: '%JrJ 1� Permit Expires On: 8/8/2016 Project Name: TRITON Owner: Name: NCWP ANDOVER EXECUTIVE PARK Address: 810 NW MARSHALLS ST #300, PORTLAND, WA, 97209 Contact Person: Name: ANDRIY HEICHENKO Phone: (206) 682-6393 Address: 1916 220TH ST SE, BOTHELL, WA, 98021 Contractor: Name: PACIFIC AIR CONTROL INC Phone: (206) 682-6393 Address: 1916 220TH ST SE, STE 101, BOTHELL, WA, 98021 License No: PACIFAC230P8 Expiration Date: 10/1/2017 Lender: Name: Address: DESCRIPTION OF WORK: INSTALLATION OF ONE UNIT HEATER, REPLACING ONE SPLIT SYSTEM (LIKE FOR LIKE), DUCTWORK REVISION, INSTALLATION OF TWO MULTI ZONE SPLIT SYSTEMS, SUPLLY FAN. Valuation of Work: $0.00 Fees Collected: $624.78 Type of Work: Electrical Service Provided by: PUGET SOUND ENERGY Fuel type: Water District: TUKWILA Sewer District: TUKWILA SEWER SERVICE Current Codes adopted by the City of Tukwila: International Building Code Edition: 2012 National Electrical Code: 2014 International Residential Code Edition: 2012 WA Cities Electrical Code: 2014 International Mechanical Code Edition: 2012 WAC 296-4613: 2014 Uniform Plumbing Code Edition: 2012 WA State Energy Code: 2012 International Fuel Gas Code: 2012 Permit Center Authorized Signature: I X Ld Y&� 4 —t Date: 0-1� f - I I hearby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this development permit and agree to the conditions attached to this permit. Signa Print Date: This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or aban0ned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: Work shall be installed in accordance with the approved construction documents, and any changes made during construction that are not in accordance with the approved construction documents shall be resubmitted for approval. 2: All permits, inspection record card and approved construction documents shall be kept at the site of work and shall be open to inspection by the Building Inspector until final inspection approval is granted. 3: Readily accessible access to roof mounted equipment is required. 4: All construction shall be done in conformance with the Washington State Building Code and the Washington State Energy Code. 5: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of this requirement. 6: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206-431-3670). 7: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center. 8: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 9: 'MECHANICAL PERMIT CONDITIONS' 10: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431-3670). 11: Manufacturers installation instructions shall be available on the job site at the time of inspection. PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 0703 MECH EQUIP EFF 1800 MECHANICAL FINAL 0609 PIPE/DUCT INSULATION 0705 REFRIGERATION EQUIP 0701 ROUGH -IN MECHANICAL 0704 SMOKE CONTROL TEST CITY OF TUKH .A Community Development Department Permit Center • 6300 Southcenter Blvd., Suite 100 Tuktivila, WA 98188 http://www.TukwilaWA.gov Mechanical Permit No. Project No. Date Application Accepted: Date Application Expires: use MECHANICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **please print** SITE LOCATION King Co Assessor's Tax No.: 022340-0010 Site Address: 530 Industry Dr Suite Number: Floor: 1 Tenant Name: Triton New Tenant: ❑ .....Yes ®..No PROPERTY OWNER Name: NCWP Andover Executive Park Address: g 10 NW Marshalls St #300 City: Portland State: OR Zip: 98209 CONTACT PERSON — person receiving all project communication Name: Andriy Heichenko Address: 1916 220th St SE City: Bothell State: WA Zip: 98021 Phone: (206) 682-6393 Fax: Email: andriyh@pacificaircontrol.com Valuation of project (contractor's bid price): $ 32,725 Describe the scope of work in detail: MECHANICAL CONTRACTOR INFORMATION Company Name: Pacific Air Control Address: 1916 220th St SE City: Bothell State: WA Zip: 98021 Phone: (206) 682-6393 Fax: Contr Reg No.: PACIFAC230P8 Exp Date: Tukwila Business License No.: BUS -0995096 Installation of one unit heater, replacing of one split system (like for like), ductwork revision, installation of two multi -zone split systems, supply fan, Use: Residential: New .......... ❑ Replacement ........ ❑ Commercial: New .......... ® Replacement ........ Fuel Type: Electric..... ❑ Gas ....... 0 Other: H:\Applications\Forms-Applications On Line\2016 ApplicationsWechanical Permit Application Revised 14-16.docx Revised: January 2016 Page] of 2 bh Indicate type of mechanical work being installed and the quantity below: Unit Type Qty Furnace <100k btu 2 Furnace >100k btu 7 Floor furnace 1 Suspended/wall/floor mounted heater 1 Appliance vent 1 Repair or addition to heat/refrig/cooling system 47 dB(A) Air handling unit <10,000 cfm 1 Unit Type Qty Air handling unit >10,000 cfm 2 Evaporator cooler 7 Ventilation fan connected to single duct 1 Ventilation system 1 Hood and duct Commercial Incinerator — domestic 47 dB(A) Incinerator — comm/industrial 65 dB(A) Unit Type Qty Fire damper 2 Diffuser 7 Thermostat 5 Wood/gas stove 57 dB(A) Emergency enerator Commercial Other mechanical equipment 47 dB(A) 60 dB(A) 65 dB(A) Boiler/Compressor Qty 0-3 hp/100,000 btu 3-15 hp/500,000 btu 15-30 hp/1,000,000 btu 30-50 hp/1,750,000 btu 50+ h /1,750,000 btu Noise: Mechanical units need to be in compliance with the Tukwila Noise Code. Maximum permissible sound levels are based on from where the sound is created and where the sound is heard. Additionally, if sound can be heard from within a house at night in a residential zone it may not be allowed. For more details, see TMC 8.22 District of Sound Producing Source District of Receiving Property Residential, Daytime* Residential, Nighttime Commercial Industrial Residential 55 dB(A) 45 dB(A) 57 dB(A) 60 dB(A) Commercial 57 dB(A) 47 dB(A) 60 dB(A) 65 dB(A) Industrial 60 dB(A) 50 dB(A) 65 dB(A) 70 dB(A) *Daytime means 7AM-1 OPM, Monday through Friday and 8AM-1 OPM, Saturday, Sunday and State -recognized holidays. A few sounds are exempt from the noise code, including: Warning devices; Construction and property maintenance during the daytime hours (lam -I Opm); Testing of backup generators during the day. PERMIT APPLICATION NOTES - Value of construction — in all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the permit center to comply with current fee schedules. Expiration of plan review — applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The building official may grant one extension of time for additional periods not to exceed 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR /® Date: 02/08/2016 Print Name: Andriy Heichenko Day Telephone: (206) 682-6393 Mailing Address: 1916 220th St SE Bothell WA 98021 City State Zip H:\Applications\Forms-Applications On Line\2016 Applications\Mechanical Permit Application Revised 1-4-16.docx Revised: January 2016 Page 2 of 2 bh DESCRIPTIONS PermitTRAK ACCOUNT QUANTITY PAID $504.63 M16-0023 Address: 530 INDUSTRY DR Apn: 0223400010 $504.63 MECHANICAL $480.60 PERMIT ISSUANCE BASE FEE R000.322.100.00.00 0.00 $32.50 PERMIT FEE R000.322.100.00.00 0.00 $448.10 TECHNOLOGY FEE $24.03 TECHNOLOGY FEE TOTAL FEES • + 1 R000.322.900.04.00 0.00 $24.03 $504.63 Date Paid: Friday, February 19, 2016 Paid By: PACIFIC AIR CONTROL INC Pay Method: CHECK 24618 Printed: Friday, February 19, 2016 11:32 AM 1 of 1 RWSYSTE/v15 Date Paid: Monday, February 08, 2016 Paid By: PACIFIC AIR Pay Method: CHECK 24568 Printed: Monday, February 08, 2016 12:34 PM 1 of 1 CRWSYS7EM5 INSPECTION RECORD 7 Retain a copy with permit � E INS ON N0. PERMIT N0. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project: T of Inspection: )CAL /A/,4L Address: Date Called: 6-34lWbUSTV-y DP Special Instructions: Date Want / m p.m. Requester. Phone No: -206 - - SS- 76 Approved per applicable codes. 0Corrections required prior to approval. VN REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. INSPECTION RECORD _� 3 Retain a copy with permit 'I� INSPECTION N0. PERMIT N0. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd.., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project: —f -k) 7V ll Type of Inspection: A 904E L Address: )'Ubtisroy brz Date Called: Special Instructions: Date Wantp.#i:�G �� P.M. Requester: Phone No: Approved per applicable codes. El Corrections required prior to approval. Z REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION RECORD [A� Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF T UKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project: Type of Inspection: I21 ry d✓ bt!ld hlalY Address: Date Called: iD vS 12 Special Instructions: Date Wanted: a.m. A( e- Requester. OPhone No: ZOG.- 3r-6-- 444 ❑Approved per applicable codes. El Corrections required prior to approval. COMMENTS: Inspector: Date: REINSPECTION FEE REQUIRED. Prior to next inspection,`fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit 1 1M )6 ��0 23 SPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project: Tiz ►ronl Type of Inspection: �VL)641 )AJ MEco Address: Date Called: 6-30 �rzDt/sTt2a/ be. Special Instructions: Date Wanted: m. % / p.m. Requester: 6-o alyvJ Phone No: ZvG-. F1Approved per applicable codes. 11 Corrections required prior to approval. ❑ REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. 3 INSPECTION RECORD X16—(3 L� Retain a copy with permit SPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request tine (206) 438-9350 Pro'ect:- Wfo k Typepf Ins ection. !��7;Tk Address: a Pr Date Calt . Special Instructions: 7/1, w" K00� } Date ted: a.m. S-3—( p.m. Requester: Phone No: Date: _ _ 3 REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd.. Suite 100. Calt to schedule reinspection. a INSPECTION RECORD Retain a copy with permit�� `fid �� INS TION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Pro'e t: J'(1' v Vt Type of Ins ection: , , I (� c Addre©: �j�j_/ _ Date -Called: Special Instructions: Date W ecl2 r /r a.m. i� p.m. Re uesster;,,V'Ve--& / � Act,— 6:izt Phone Nom Inspector: Dater _ 2,7_(r ❑ REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION RECORD/0) -3 INSPECTION Retain a copy with permit INSPECTION NO. PERMIT NO, CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Pr t: • Tynof Ins ction: S ` Address: Date Called: Special Instructions: If Date W nted. a.m. ✓2-f— _ p.m. Requester: Phone No: ❑ Approved per applicable codes. Corrections required prior to approval. COMMENTS: r� o� Q ,e F REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southc enter Blvd., Suite 100. Call to schedule reinspection. PERMIT COORD COPY PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: M16-0023 PROJECT NAME: TRITON SITE ADDRESS: 530 INDUSTRY DR X Original Plan Submittal DATE: 02/08/16 Revision # Response to Correction Letter # Revision # DEPARTMENTS: H� Building Division 6 Public Works ❑ PRELIMINARY REVIEW: Not Applicable ❑ (no approval/review required) REVIEWER'S INITIALS: APPROVALS OR CORRECTIONS: Approved ❑ Corrections Required ❑ (corrections entered in Reviews) Notation: REVIEWER'S INITIALS: before Permit Issued after Permit Issued At� 01,4- *)--Il-//(o Fire Prevention ® Planning Division ❑ Structural ❑ Permit Coordinator ❑ DATE: 02/09/16 Structural Review Required ❑ DATE: DUE DATE: 03/08/16 Approved with Conditions Denied ❑ (ie: Zoning Issues) DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: 12/18/2013 PACIFIC AIR CONTROL INC t Washington State Department of Labor & Industries PACIFIC AIR CONTROL INC Owner or tradesperson Principals RUTTAN, GARY JAMES, PRESIDENT CRAWFORD, LARRY C, SECRETARY (End: 10/05/2011) Doing business as PACIFIC AIR CONTROL INC WA UBI No. 601 298 907 License Home : Espanol ' Contact. Safety & Health Claims & Insurance 1916 220TH ST SE STE 101 BOTHELL, WA98021-8427 206-682-6393 SNOHOMISH County Business type Corporation Page 1 of 2 Search L&I A -Z Inde Workplace Rights Verify the contractor's active registration / license / certification (depending on trade) and any past violations. Construction. Contractor Active. Meets current requirements. License specialties Heating/Vent/Air-Conditioning and Refrig (HVAC/R) License no. PACIFAC230138 Effective — expiration 10/28/1977-10/01/2017 Bond ................. TRAVELERS CAS & SURETY $6,000.00 Bond account no. 104920215 Received by L&I Effective date 05/09/2007 05/26/2007 Expiration date Until Canceled https:Hsecure.Ini.wa.gov/verify/Detail.aspx?UBI=601298907&LIC=PACIFAC23OP8&SAW= 2/19/2016 HVAC GENERAL NOTES 1. VERIFY SITE CONDITIONS. 2. THERMOSTAT LOCATIONS: VERIFY ALL WALL MOUNTED CONTROL LOCATIONS WITH ARCHITECT/GC. 3. CODES: COMPLY WITH ALL LOCAL & STATE GOVERNING CODES. 4. COORDINATE DUCTWORK AND GRILLE LOCATIONS WITH LIGHTING AND OTHER RELATED TRADES WITH ARCHITECT APPROVAL. VERIFY CLEARANCES & CEILING ELEVATIONS BEFORE INSTALLATION. 5. DRAWINGS ARE SCHEMATIC IN SOME AREAS AND MAY NOT SHOW EXACT ROUTING OR EVERY OFFSET WHICH MAY BE REQUIRED. 6. SEISMIC BRACING: PROVIDE TO MEET LOCAL CODE REQUIREMENTS. REFER TO THE ASHRAE STANDARDS "PRACTICAL GUIDE TO SEISMIC RESTRAINT", 2012. 7. EXHAUST FAN TERMINATION: SHALL NOT BE LESS THAN 3 FEET FROM A PROPERTY LINE OR OPENINGS INTO A BUILDING, E.G., OPERABLE WINDOWS AND DOORS, OR DISTANCE AS REQUIRED PER LOCAL CODE. 8. TEST, ADJUST, & BALANCE: PROVIDE PROPER SYSTEM TESTING, ADJUSTING, AND BALANCING, INCLUDING WRITTEN REPORTS TO BE PROVIDED TO OWNER. BALANCE TO WITHIN 10% OF DESIGN. 9. OPERATION & MAINTENANCE BOOKLET: PROVIDE 0 & M MANUAL TO OWNER. INCLUDE CUT SHEETS ON MAIN EQUIPMENT AND CONTROLS, MAINTENANCE INSTRUCTIONS, AND MARKED UP AS -BUILT DRAWING. 10. COMMISSIONING: PRIOR TO PASSING THE FINAL INSPECTION OR OBTAINING A CERTIFICATE OF OCCUPANCY, PROVIDE THE EVIDENCE OF SYSTEM COMMISSIONING AND COMPLETION IN ACCORDANCE WITH THE PROVISIONS OF SECTION C408 OF THE 2012 WSEC 11. WALK-THRU INSTRUCTION: PROVIDE ON SITE WALK-THRU FOR CUSTOMER TO DEMONSTRATE OPERATION OF SYSTEM AND ANSWER QUESTIONS. 12. ROOF TOP UNITS ON CURB: SEAL HOLES AND CRACKS BETWEEN DUCT AND ROOF DECK INSIDE FACTORY ROOF CURB FOR NOISE CONTROL. 13. GAS PIPE: SCHEDULE 40, BLACK STEEL. PAINT PIPE EXPOSED TO WEATHER. 14. SIZES: ALL PIPE SIZES SHOWN ARE MINIMUM. 15. PIPE HANGERS: SWIVEL LOOP STYLE, MICHIGAN NO. 100 OR CLEVIS STYLE, NO.400 OR EQUAL BRAND, WITH ALTHERED STEEL ROD SIZED PER INDUSTRY STANDARDS. 16. ELECTRICAL: ALL EQUIPMENT TO HAVE A POSITIVE MEANS OF DISCONNECT ADJACENT TO AND IN SIGHT FROM EQUIPMENT SERVED. PROVIDE A 120 VOLT RECEPTACLE LOCATED WITHIN 25 FEET OF EQUIPMENT FOR SERVICE & MAINTENANCE PURPOSES (2012 IMC SECTION 301.10). LINE VOLTAGE WORK BY OTHERS. DUCT NOTES 1. DUCT CONSTRUCTION AND INSTALLATION PER LATEST SMACNA STANDARDS AND THE 2012 IMC AS REQUIRED BY THE LOCAL CODE. PROVIDE METAL DUCT, EXCEPT AS NOTED. 2. BALANCING DAMPERS: PROVIDE ON ALL SUPPLY RUN OUT DUCTS UP STREAM OF DIFFUSERS. 3. DUCT INSULATION: DUCTS, SHAFTS AND PLENUMS SHALL BE INSULATED TO MINIMUM OF R-8 AND IN ACCORDANCE WITH THE SECTION C403.2.7 OF 2012 WSEC. 4. DUCT SEALING -GENERAL: 0 TO 2" STATIC PRESSURE - SEAL ALL TRANSVERSE JOINTS AND LONGITUDINAL SEAMS ON ALL DUCTS. ABOVE 2" -SEAL SEAMS, JOINTS AND WALL PENETRATIONS. INSIDE BUILD: DURODYNE "DDS -181" GRAY OR APPROVED EQUAL PER UL 181 A -M, 181B -M LISTED. OUTSIDE: POLYURETHANE, MAMECO VULKEM 116. OR APPROVED EQUAL. 5: TURN VANES: PROVIDE SINGLE THICKNESS TURN VANES (SEE DETAIL) IN ALL MAJOR SQUARE DUCT ELBOWS, TEES, OR TURNS WITH INSIDE RADIUS LESS THAN 3/4 DUCT WIDTH. SQUARE BRANCH DUCT TAPS SHALL BE 45 DEGREE TYPE PER SMACNA STANDARD. 6. FLEX DUCT (INSULATED): FOR GRILLE RUN OUTS UP TO 6 FT. LONG, EXCEPT AS NOTED. PROVIDE ADJUSTABLE METAL ELBOWS ON ALL TURNS, UNLESS A SMOOTH FULL RADIUS TURN IS MADE. SECURE CORE WITH APPROVED NYLON OR METAL WORM DRIVE CLAMPS. NO DUCT TAPE JOINTS & SCREWS ALLOWED. 7. SOUND LINER: PROVIDE SOUND LINED METAL SUPPLY & RETURN DUCTS AS SHOWN ON PLANS. MANVILLE PERMACOTE LINACOUSTIC FLEXIBLE FIBERGLASS LINER, WITH ACRYLIC SURFACE TREATMENT OR EQUAL. FABRICATE AND INSTALL PER DUCT LINER STANDARD OF NORTH AMERICAN INSULATION MANUFACTURER'S ASSOC. OUTSIDE AIR DUCT IS NOT INSULATED THROUGH UNCONDITIONED AREA. 8. FLEX CONNECTORS: PROVIDE ON ALL DUCT HOOK-UPS TO ISOLATE AIR HANDLING EQUIPMENT. (NEOPRENE COATED FIBERGLASS FABRIC TYPE) 9. DUCT SIZE CHANGES: ROUND GALVANIZED DUCTS MAY BE SUBSTITUTED FOR RECTANGULAR DUCTS THAT ARE NOT LINED. PROVIDE CIRCULAR EQUIVALENT OF RECTANGULAR DUCT. OTHER EQUIVALENT RECTANGULAR DUCT SIZES MAY BE SUBSTITUTED TO BETTER FIT SPACE. 10. TEMPORARY DUCT CLOSURE: SEAL OFF DUCTWORK DURING CONSTRUCTION TO KEEP OUT CONSTRUCTION DUST, ESPECIALLY FLOOR BOOTS AND LOW WALL OPENINGS. 11. SUPPLY DIFFUSERS: CD -1: SHOEMAKER 700 MA SERIES, 2X2 MODULAR CORE T -BAR LAY -IN DIFFUSER, SQUARE COLLAR, SOFT WHITE FINISH OR EQUAL; CD -2: SHOEMAKER MA SERIES, MODULAR CORE CEILING DIFFUSER, SQUARE COLLAR, SOFT WHITE FINISH OR EQUAL. 12. RETURN GRILLES: RG -1: SHOEMAKER AL SERIES, EGGRATE LATTICE T -BAR RETURN, SOFT WHITE OR EQUAL; RG -2: SHOEMAKER 600 SERIES, ALUMINUM SURFACE MOUNT LATTICE RETURN AIR GRILLE WITH EXTRUDED ALUMINUM FRAME, SOFT WHITE OR EQUAL. LEGAL DESCRIPTION: POR W 1/2 OF SEC 25 & E 1/2 OF SEC 26 AS FOLG BEG AT E 1/4 COR SEC 26 TH N 88-06-42 W 105.84 FT TO TPOB TH N 01-47-28 E 2.45 FT TAP OF CURVE TH ALG A CURVE TO RGT RAD 410.28 FT THRU C/A OF 46-46-10 ARC DIST 334,90 FT TH N 48-33-38 E 188.36 FT TH ALG A CURVE TO RGT RAD 410.28 FT THRU C/A OF 72-16-35 ARC DIST 517.55 FT TO AN NXN WITH A LN BEARING S 56-38-20 E TH S 56-38-20 E ALG SD LN 69.93 FT TH S 48-44-23 E 71.30 FT TH S 45-09-27 E 9.91 FT TO WLY MGN OF JAMES CHRISTENSEN RD NO 1479 TH S 37-54-41 W 468.23 FT TH S 32-39-25 W 132.67 FT TH N 88-12-32 W 524.50 FT TH N 01-47-28 E 93.11 FT TO TPOB LESS UP RR OPER R/W TAX PARCEL NUMBER: 332304-9001 AREA OF WORK SEPPiPIATE PERMIT REQUIRED FOR. ❑ Mechanio G'Electdcal 13'"Illumbing G?ffas Piping City of Rikwifst IQILIDING DIVISRIN No changes shall be made to the saW of work without prior approval of Tuki,vila Building Division. NOTE: Revisions will require a new pian submittal and may include additional plan review tees. 4 �. /001, /% j ////j//��/////// /j10 // /// VICINITY MAP NTS Andover Ececutive Park Triton NTS LEGEND & ABBREVIATIONS SYMBOL DRAWING INDEX M-1 LEGEND & ABBREVIATIONS, VISINITY MAP, NOTES M-2 EXISTING HVAC SYSTEM M-3 NEW HVAC SYSTEM, EQUIPMENT SHCEDULE MA NEW ROOFTOP EQUIPMENT, CEILING REFLECTION PLAN LEGAL DESCRIPTION: POR W 1/2 OF SEC 25 & E 1/2 OF SEC 26 AS FOLG BEG AT E 1/4 COR SEC 26 TH N 88-06-42 W 105.84 FT TO TPOB TH N 01-47-28 E 2.45 FT TAP OF CURVE TH ALG A CURVE TO RGT RAD 410.28 FT THRU C/A OF 46-46-10 ARC DIST 334,90 FT TH N 48-33-38 E 188.36 FT TH ALG A CURVE TO RGT RAD 410.28 FT THRU C/A OF 72-16-35 ARC DIST 517.55 FT TO AN NXN WITH A LN BEARING S 56-38-20 E TH S 56-38-20 E ALG SD LN 69.93 FT TH S 48-44-23 E 71.30 FT TH S 45-09-27 E 9.91 FT TO WLY MGN OF JAMES CHRISTENSEN RD NO 1479 TH S 37-54-41 W 468.23 FT TH S 32-39-25 W 132.67 FT TH N 88-12-32 W 524.50 FT TH N 01-47-28 E 93.11 FT TO TPOB LESS UP RR OPER R/W TAX PARCEL NUMBER: 332304-9001 AREA OF WORK SEPPiPIATE PERMIT REQUIRED FOR. ❑ Mechanio G'Electdcal 13'"Illumbing G?ffas Piping City of Rikwifst IQILIDING DIVISRIN No changes shall be made to the saW of work without prior approval of Tuki,vila Building Division. NOTE: Revisions will require a new pian submittal and may include additional plan review tees. 4 �. /001, /% j ////j//��/////// /j10 // /// VICINITY MAP NTS Andover Ececutive Park Triton NTS LEGEND & ABBREVIATIONS SYMBOL ABBREV, DESCRIPTION 00 SUPPLY DUCT 00 RETURN/EXHAUST DUCT 0 SL SOUNDLINED DUCT VD MANUAL VOLUME DAMPER p FC FLEX CONNECTOR TV TURNING VANES r, EC END CAP ® SD SUPPLY DIFFUSER, CEILING ® MG MAKEUP GRILLE ® RG RETURN GRILLE, CEILING ® EG EXHAUST GRILLE, CEILING ® TG TRANSFER GRILLE, CEILING BSC SIDEWALL SUPPLY/MAKEUP -� CFH SIDEWALL RETURN/EXHAUST •111 -271 • EQUIPMENT TAG AFF ABOVE FINISHED FLOOR BD, BDD BACKDRAFT DAMPER BS BIRDSCREEN DN DOWN EA EXHAUST AIR OA, OSA OUTSIDE AIR RA RETURN AIR SA SUPPLY AIR (I) NEW (E)/EXIST EXISTING (R) RELOCATED BWG BOTTOM WALL GRILLE TWG TOP WALL GRILLE TYP TYPICAL VD VOLUME DAMPER 00 DEMO REVISIONS AIR TERMINAL LEGEND SYMBOL ABBREV. DESCRIPTION FIRE DAMPERED DUCT PENETRATION OF A HORIZONTAL SEPARATION FIRE DAMPERED DUCT PENETRATION OF A VERTICAL SEPARATION O TIMER 0-4 HR ADJUSTABLE 0 THERMOSTAT/HVAC UNIT # Q SENSOR/HVAC UNIT # 0 SENSOR (CEILING MOUNT) EXHAUST FAN p _❑ PIPE/DUCT UP LEGEND & PIPE/DUCT DOWN r, PIPE TEE DOWN v 0 PIPE TEE UP EXIST DUCTWORK, EQUIP _w...,,_......_... ,. _._.-,.. NEW DUCTWORK, EQUIP ADJ ADJACENT BSC BIOLOGICAL SAFETY CABINET CFH CHEMICAL FUME HOOD CFM CUBIC FEET PER MINUTE DB DUCT BOARD L'S LIQUID, SUCTION N NECK NIC NOT IN CONTRACT OAI OUTSIDE AIR INTAKE RD ROUND DIFFUSER SHC SENSIBLE HEATING CAPACITY SR SUPPLY REGISTER TC TOTAL COOLING VEL VELOCITY WH WATER HEATER GRILLE, REGISTER, XX 8x8 NECK SIZE (INCHES) DIFFUSER IN LEGEND 140 SQUARE OR RECTANGULAR AIR QUANTITY (CFM) XX 8110 --- NECK SIZE (INCHES) 140 ROUND Air Quantity (CFM) ARROWS INDICATE AIR PATTERN FOR CEILING DIFFUSERS NO ARROWS INDICATE FOUR WAY PATTERN DESCRIPTION OF WORK: 1. REZONING CURRENT DUCT SYSTEMS PER DRAWINGS, SEE M-2 & M-3 2. CHANGE LIKE FOR LIKE EXISTING SPLIT SYSTEM. 3. DISCONNECT AND REMOVE EXISTING HEATER UNIT AND INSTALL NEW UNIT. RE VIED FOR - CODE. CODE: CQMPLIANCE APPROVED FEB 18 2016 CIS bf Tukwila BUILDING DIVISION 4. INSTALL TWO MULTI -ZONE SPLIT SYSTEMS PROVIDING MINIMUM REQUIRED OUTSIDE AIR, SEE M-3 & M-4. 5. REPLACE OLD EXHAUST FANS IN EXPANSION OFFICE AREA. RLE COPY 5. REBALANCE ALL DIFFUSERS PER DRAWING, SEE M-3. Permit No. 0023 Plan review approval is subject to errors and omissions. Approval of construction documents does not authorize the violation of any adopted code or ordinance. Recoipt of approved Field Copy d conditions is acknowledged: By: -- Date: f City of Tukwila BUILDING DIVISION ----------- ----- - ------ __._.. --- FLEPATH'�PROJECTS�ANDCVER�ANDOVERTRITON Air Conditioning Heating Controls Sales Service Installation "QUALITY ASSURED" pacific air control, inc. 1916 220th Street SE Suite M101 Bothell, WA 98021 ph: (206) 682-6393 fax: (206) 340-2270 Contractor's License No.: PACIFAC230P8 www.pacificaircontrol.com MAP, NOTES, & SHEET INDEX A_ _ .� J/ i:.l j . 1,�, f I_ SNEer NUMPER PE of 4• A;R ('010ROi., PIC. KC KC i)RA WN Rr CrrECEE-n 5 - AH KC RRO.xcr 140. -- -- NOT-TO-SCALE T150918 DRM'rlPiG HILTS LEGEND & ABBREVIATIONS, VICINITY MAP, NOTES, & SHEET INDEX A_ _ .� J/ i:.l j . 1,�, f I_ SNEer NUMPER PE of 4• A;R ('010ROi., PIC. GARAGE DOOR �� �� �� �������� � ����s����au�� GARS.'- DOOR I I ! (E) 14"GAS LINE 8X8 8X8 < �s MA MA CP$ XH P - 4 HIGH SIDE WAL5-TONWAF[1$ C?�.65 1050 I TRANSFER OPEN TC` RAFTERSABOVE _ 'I 8" 12" e ��-13' AFF i CAP 16x8 j SL 14xl 44 88X8 - - SL MA i � (E)HU-1 ( TRANSFER ! 10" so 12x12 �} H P - S J� TYP.(4) J I-TON'IARR 1011>E LIE 12" e 10"o I� OPFI'J TO F' --TER AF0WF AFF 12x30 DB D , CAP" 10 o I 10"e II 8'o j 14;a " / 10x10 i MA 10 e - � r Supply is from 8"o4-2 " x8 j1 MA i 8x8 -T —r - Q MA JIV rr 8X8 — r TYP.(2) 8110 / i i i Honeywell S 12" ,a Sensor H P - 6 X 4 -TON a 5 v 12x12 07 MA 10x10 1 950 ------ Refrigerant Line `JUMPER 3 1"X14" 12x8 Honeywell Sensor Sidewall 12x8 OSA ---- I ntake i' 8x8 MA - 1 4-4A 8x8 8 MA 12"x22" jD B i 10x10 MA ----- 10 - 10"e 10"e Fan I —I i E) Fan 10x10 10x10 --- MA MA - - - ANDOVER TRITON: NORTH SCALE: 16� = 1 EXISTING HVAC SYSTEM FILEPATH; !PROJECTS\AN Air conditioning Heating Controls Sales Service Installation Em "QUALITY ASSURED" pacific air control, inc. 1916 220th Street SE Suite M101 Bothell, WA 98021 ph: (206) 682-6393 fax: (206) 340-2270 Contractor's License No.: PACIFAC230138 www.pacificaircontrol.com JJQ. 0A TE OFSCRIPTlON 2/1/16 PERMIT -ISSUE A N0 JL''! !!AAAG'LN OL rGP1ED 131' KC KC DRA!ShJ DIY ------ --CFiEi;(Ef) 8i --..--- AH KC --------- sr !_E — - PROJECT NO. 3/16"= V T150918 EXISTING -HVAC -SYSTEM C,: r FEB 0 8 2016 PERMIT CENTER REVIEWED FOR.:. CODE CiO PLII� CSE SHEET NUMUEF APPOV FEB 18 2016 City of TUWIa BUILDING DIVISIOI'� Control Diffusser (E) 1-41" GASLINE - — - ------ ------- 8x8 EXISTING 8X8 OFFIC I (N) 1� 1 " GAS 220 CFM OFFICE -A 50 CFM-'*-', LINE - F 0 (N) HU -2 (60' From 8 it 0Gas 0 Meter) (E) 3/4" GAS 8"0 LINE 8CAP H P - 4 5 -TON I,) 16x81 SL (N)16" tt SHARED OFFICE Oo 10 0 529 RESTOOIVI HP -5 Otto 3 -TON ( 12x30 DB �7D CAP R)l OxI 0 220 CFM pply is off 100 oil DB (N)l OXI 0 250 10"o ---CFM (E) 12x12 (N' 380 CFM (N)l 0 o TYP. (4) 0 IKN)l 0" (N) 12 N)l o (N) j4 "o EXISTING BREAK STORAGE IN WALL 01 .00, SHARED OFFICE --- — ----- 1 6) '.' ' SMOKE/FIRE DAMPE NMA 525 52) 8 535 SEE DETAIL -1, M-4 8X8 0240 CFM NMI 7, (R)8 0 8 0 R 0 M 0L llxllDB (E) 8X8 Doghouse Roofcurb Doghouse Roofcurb LF-- ,0 200 CFM 10 9-1 OA FAN ///'A 8 0 TYP. (2) 0 H P - E 120 6 0 AH -1 6x6 6„0 (N)700 6 0) 0 8 0 101” 0 4 -TON (N)8"o 75 CFM 6x6 0 C 12x12 COI\ FF E 10 0 8X8 1. RI-NCEFM 170 8X8 CFM 260 120 10111 CFM 110X10 CFM 170 TO EXISTING EXHAUST AUST SYSTEM / efrigerant Line \I(N)JUMPER 3 J"X14" / / H-3 6'0 TECH 6 N 950 JE)950 IM 12X8 J L 4 290 CFM270 CFM NWALL 14_ 1 -6 TRANSFER E - GRILL NEW SHARED AH -4 N 700 SHARED OFFICE OFFICE E 6x6 E\/,\/IS-IING 521 51 L 20 CFM 0 F F I CF - - 1', r [-.11! V,-! ')FF C- (R)8x8 E- 6x6 10, 130 CONFERENCE A I FAN -2 150 75 CFM CFM510 CFM F 2 41MNOT/ BE,/Nniv 0 I,,JK--/H/0)UR�'R J/Ff) A rz /TT� Arz I E 111.1 D F)" CAf I O,r\]' OF I F**- � CQRi FD�,DO -Iv J' NOR �/'S\'/`S)TE74v -/Uf�P, TU K/- (R)Sidew11/l 2X8 EH AN, "2 6"o —�1ith-,Smakb/Fi.6 - — -------- --- - - amper 200/1 M X n 22X1 2 01111. S C, 105 CFM (N)700 / / /8x8 (E)OSA .. . ........ . ... . .......... -41 SHARED OFFICE 100 CFM Lj— NEW OFFICE NEW Intake CO- 5, 0 4 /,/F;EC"EF'TIpt,'1fSTORAGE950n-Ceffing---AH TRANSFER RA (N) 10x GRILL 6X6 10 x 6 TYP. (2) ti7 140 CFM10 . ..... ..... .... 10'0 NEW OFFICE jln Ceiling 1000 (N)700 TRANSFER 8X8 I 520 GRILL 6X6 350 CFM 150 QFIVI X/ TYP.(2) NEW OFFICEF-) U 1. vr-:l SHARED OFFICE 503 516 10 X10 MA SHARED OFFICE /Z- 320 CEM 515 ANDOVER TR ITO X10 NEW HVAC P LAN - o 3 ) ) NORTH SCALE. 16 1 SMOKE FIRE DAMPER J oWRAP r DF'Alih'•1 RY ------ CEiFi;KFD B)' -- AH KC sc.•aLc ------ ProiLcr NO. - — 3/16"=1' 0 0 DRAPWNG !TILE;; DERAIL:SMOKE/FIRE_DAMPER 2 1 AYER- FRAME-/ OPENING 11 "X1 1 " 0 0 0 0 0 0 0 0 0 0 0 0 0 S S S S S S 5 S S GRILL 10X10 CORRIDOR 1 .DETAIL: SMOKE FIRE DAMPER SCALE: NTS -STEEL STUD FRAMING —1 HP -2 8 $$0 OA INTAKE 10- FROM EXHAUST HP -1 Lower ceiling due to ductwork run. U\-/ S E ROOFCURB 8"0 EXHAUST 2.ANDOVER TRITON: NEW ROOFTOP EQUIPMENT SCALE: 3/32" = V- 0" Possible lower ceiling El due to ductwork run. L11 Lower ceiling due to ductwork run. &ANDOVER TRITON: CEILING REFLECTION PLAN SCALE: 3/16" = 1'- 0" PC "QUALITY ASSURED" pacific air control, inc. 1916 220th Street SE Suite M101 Bothell, WA 98021 ph: (206) 682-6393 fax: (206) 340-2270 Contractor's License No.: PACIFAC230P8 Air Conditioning Heating Controls Sales Service Installation www.pacificaircontrol.com n u�t �t v,�Yaa -Nktli�9w*N d�TM i N0. DA;F DF,CANPT'ON 2/1/16 PERMIT—ISSUE _A T4 -X E.C! h.!r1idAGE'i' KC L'ES(cNED N1' KC DF'Alih'•1 RY ------ CEiFi;KFD B)' -- AH KC sc.•aLc ------ ProiLcr NO. - — 3/16"=1' T150918 DRAPWNG !TILE;; DERAIL:SMOKE/FIRE_DAMPER NEW—ROOFTOP—EQUIPMENT __J CEILING—REFLECTION—PLAN FILEPATH:!PROJECTS\AN REWEWED FOR CODE CQMPLIAN CE ',. APPROVED FEB 1.8 2016 }' City of Tukwila BUILDING DIVISION) SHEET NUMPER of 4 ncrrfC „rP Co!v7T:01, R