HomeMy WebLinkAboutPermit M16-0033 - T BAR CONSTRUCTION - GAS / ELECTRIC ROOFTOP UNITS AND DUCT SYSTEMST BAR CONSTRUCTION
14590 INTERURBAN AVE S
M16-0033
City of Tukwila
' Department of Community Development
• 6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206-431-3670
Inspection Request Line: 206-438-9350
Web site: http://www.TukwilaWA.gov
MECHANICAL PERMIT
Parcel No:
3365901630
Permit Number: M16-0033
Address:
14590 INTERURBAN AVE S
Issue Date: 3/29/2016
WA Cities Electrical Code:
2014
Permit Expires On: 9/25/2016
Project Name:
T BAR CONSTRUCTION
2014
Owner:
2012
WA State Energy Code:
Name:
SANFT LOUIE
2012
Address:
6120 52ND AVE S, SEATTLE, WA,
_
98118
Contact Person:
Name:
BILL ALSEPT
Phone: (425) 754-8759
Address:
3903 SMITH AVE, EVERETT, WA,
98201
Contractor:
Name:
WILLIAMS MECHANICAL INC
Phone: (425) 303-0828
Address:
3903 SMITH AVE, EVERETT, WA,
98201
License No:
WILLIM1088PA
Expiration Date: 10/1/2017
Lender:
Name:
Address:
DESCRIPTION OF WORK:
INSTALL 2 GAS/ELECTRIC
ROOF TOP UNITS WITH NEW
DUCT SYSTEMS
Valuation of Work: $14,000.00
Fees Collected: $376.54
Type of Work: NEW
Electrical Service Provided by: PUGET SOUND ENERGY
Fuel type: GAS
Water District: TUKWILA
Sewer District: TUKWILA SEWER SERVICE
Current Codes adopted by the City of Tukwila:
International Building Code Edition:
2012
National Electrical Code:
2014
International Residential Code Edition:
2012
WA Cities Electrical Code:
2014
International Mechanical Code Edition:
2012
WAC 296-466:
2014
Uniform Plumbing Code Edition:
2012
WA State Energy Code:
2012
International Fuel Gas Code:
2012
_
Permit Center Authorized Signature:
lb
I hearby certify that I have read and examined this permit and know the same to be true and correct. All
provisions of law and ordinances governing this work will be complied with, whether specified herein or not.
The granting of this permit does not presume to give authority to violate or cancel the provisions of any other
state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this
development permit and agree to the conditions attached to this permit.
Signature: LI Date: A�
Print Name: LO Vl/. 'SyV
This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if
the work is suspended or abandoned for a period of 180 days from the last inspection.
PERMIT CONDITIONS:
1: Work shall be installed in accordance with the approved construction documents, and any changes made
during construction that are not in accordance with the approved construction documents shall be
resubmitted for approval.
2: All permits, inspection record card and approved construction documents shall be kept at the site of work
and shall be open to inspection by the Building Inspector until final inspection approval is granted.
3: Readily accessible access to roof mounted equipment is required.
4: All construction shall be done in conformance with the Washington State Building Code and the
Washington State Energy Code.
5: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the
City of Tukwila Building Department (206-431-3670).
6: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila
Permit Center.
7: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an
approval of, any violation of any of the provisions of the building code or of any other ordinances of the City
of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other
ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction
documents and other data shall not prevent the Building Official from requiring the correction of errors in
the construction documents and other data.
8: `MECHANICAL PERMIT CONDITIONS'
9: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila
Permit Center (206/431-3670).
10: Manufacturers installation instructions shall be available on the job site at the time of inspection.
PERMIT INSPECTIONS REQUIRED
Permit Inspection Line: (206) 438-9350
0703
MECH EQUIP EFF
1800
MECHANICAL FINAL
0609
PIPE/DUCT INSULATION
0705
REFRIGERATION EQUIP
0701
ROUGH -IN MECHANICAL
CITY OF TUKW_
Community Development Department
• Permit Center
• 6300 Southcenter Blvd., Suite 100
Tukwila, WA 98188
http://w,,v\v.Tukwi]aWA.gov
Mechanical Permit No. ''' 1I`Q' V�
Project No.
Date Application Accepted:
Date Application Expires: _
use
MECHANICAL PERMIT APPLICATION
Applications and plans must be complete in order to be accepted for plan review.
Applications will not be accepted through the mail or by fax.
"please print"
SITE LOCATION
10 King Co Assessor's Tax No.: 3365901650
Site Address: 1 Interurban ave..�S Building B Suite Number: 1 Floor: 1
Tenant Name: ai9� C6WS//�V1-Cy,/ New Tenant: 0 .....Yes ❑ ..No
PROPERTY OWNER
Name:
Address:
City: State: Zip:
CONTACT PERSON — person receiving all project
communication
Name: bill alsept
Address: 3903 smith ave
City: everett State: wa Zip: 98201
Phone: (425) 754-8759 Fax:
Email: bill@williams-mechanical.com
MECHANICAL CONTRACTOR INFORMATION
Company Name: williams mech inc
Address: 3903 smith ave
City: everett State: wa Zip: 98201
Phone: (425) 754-8759 Fax:
Contr Reg No.: WILLIM088PA Exp Date:
Tukwila Business License Nd`v
Valuation of project (contractor's bid price): $ 14,000
Describe the scope of work in detail:
Install two gas/electric roof top units with new duct systems.
Use: Residential: New .......... ❑ Replacement ........ ❑
Commercial: New .......... ® Replacement ........ ❑
Fuel Type: Electric..... ❑ Gas ....... m Other:
H:\Applications\Forms-Applications On Line\2011 Applications\Mechanical Permit Application Revised 8-9-11.docx
Revised: August 2011 Page] of 2
bb
Indicate type of mechanical work being installed and the quantity below:
Unit Type
Qty
Furnace <100k btu
Furnace >I 00k btu
10
Floor furnace
1
Suspended/wall/floor
mounted heater
Appliance vent
Repair or addition to
heat/refrig/cooling
system
Air handling unit
<10,000 cfm
2
Unit Type
Qty
Air handling unit
>10,000 cfin
Evaporator cooler
10
Ventilation fan
connected to single duct
1
Ventilation system
Hood and duct
Incinerator — domestic
Incinerator —
comm/industrial
PERMIT APPLICATION NOTES -
Unit Type
Qty
Fire damper
Diffuser
10
Thermostat
1
Wood/gas stove
Emergency enerator
Other mechanical
equipment
Boiler/Compressor Qty
0-3 hp/100,000 btu
3-15 h /500,000 btu
15-30 hp/1,000,000 btu
30-50 hp/1,750,000 btu
50+h /1,750,000 btu
Value of construction — in all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject
to possible revision by the permit center to comply with current fee schedules.
Expiration of plan review — applications for which no permit is issued within 180 days following the date of application shall expire by limitation.
The building official may grant one extension of time for additional periods not to exceed 90 days each. The extension shall be requested in writing
and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition).
I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER
PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT
BUILDING OWNER OR
AUUTHHO
Signature: !/[/
Print Name: Bill Alsept
Mailing Address: 3903 smith ave
AGENT:
Day Telephone:
everett
city
Date: 03/02/2016
wa 98201
State Zip
MApplicationsTorms-Applicat ions On Line\2011 Applications\Mcchanical Permit Application Revised 8-9-11.docx
Revised: August 2011 Page 2 of 2
bh
DESCRIPTIONS
PermitTRAK
•
QUANTITY
PAID
$580.58
EL16-0187 Address: 14590 INTERURBAN AVE S
Apn: 3365901630
$77.28
ELECTRICAL
$73.60
PERMIT FEE MULTI-FAM/COMM
R000.322.101.00.00
0.00
$73.60
TECHNOLOGY FEE
$3.68
TECHNOLOGY FEE
R000.322.900.04.00
0.00
$3.68
M16-0033 Address: 14590 INTERURBAN AVE S
Apn: 3365901630
$376.54
MECHANICAL
$362.06
PERMIT ISSUANCE BASE FEE
R000.322.100.00.00
0.00
$32.50
PERMIT FEE
R000.322.100.00.00
0.00
$257.15
PLAN CHECK FEE
R000.322.102.00.00
0.00
$72.41
TECHNOLOGY FEE
$14.48
TECHNOLOGY FEE
R000.322.900.04.00
0.00
$14.48
PG16-0025 Address: 14590 INTERURBAN AVE S
Apn: 3365901630
$126.76
GAS
$121.88
PERMIT ISSUANCE BASE FEE
R000.322.100.00.00
0.00
$32.50
PERMIT FEE
R000.322.100.00.00
0.00
$65.00
PLAN CHECK FEE
R000.322.103.00.00
0.00
$24.38
TECHNOLOGY FEE
$4.88
TECHNOLOGY FEE
TOTAL FEES PAID '
R000.322.900.04.00
0.00
$4.88
1 .58
Date Paid: Thursday, March 03, 2016
Paid By: BILL ALSEPT
Pay Method: CREDIT CARD 075768
Printed: Thursday, March 03, 2016 12:02 PM 1 of 1��
SYSTEMS
0
INSPECTION RECORD
2i
nRetain a copy with permit
IN SPtTT10N N0. PERMIT N0.
CITY OF TUKWILA BUILDING DIVISION
6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670
Permit Inspection Request Line (206) 438-9350
Proje t:
Type of Inspection:
Ad/Id��ress:
"l ® e
Date Called:
e
Special Instructions:
Date W anted: a.m.
4 p.m.
Requester:
i( 1009
Phone/ No: p,
-I 2-5--7-� 0 7S—
Inspector: Date:
El REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be
paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection.
tom-,
INSPECTION RECORD
Retain a copy with permit �f�,-o�33
INSP "ON N0, PERMIT NO.
CITY OF TUKWILA BUILDING DIVISION
6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670
Permit Inspection Request Line (206) 438-9350
Inspector: Date:
-, --3
REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be.
paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection.
D
M
O
r-
0
O
w
C
N
W C)
CL :r
J
U r °)
L _
Z `o Q
20
Q
W
Cl)
O
�co
_ry
Y �m
W
CL m
J OQ
O
U
CD
J EQ
Op
O 1 ''n
Uc0
Y
m
N
CL
O O 100 N MOO O I- o
Oe 0000 000)O 00
00VONNc-0 Nn
a0
Y 0 0000 LO C14 O)O ('
a(°'nm v a(Do U.
N r c= m
0 .- 1L (M
0~ 0<=C
=ju
Y yr 0000 004
IL (n
!it
0? Lu
CL CL
> LU
m m LU C)
° U
`m c .0 U ` 00 ti II
0-0
m(nU �<�� 02 c.0
6,U o L)i mI°
CO a .Y O O O m N 0 "O
(n(nT-C5C53:aLLQscn
W
w°o 0000)vovoo(n N
d O `•'
� F-
CL 0
V
d L 0 0 0 (O (! W'T 0 0 0 r
mBO �OOCO O(D
C. Nm N7� �•N N
In
43)
/n
r e
ITN N N M 0 0 0
V 0
0L0 OO O M M 0(DM0 000
C (D O O (D r
zd
C 0)
0)h N_ N
d r -
6
D. O
(a II
0
N M
OOI�N
O N
OD LD
NOM(D (D
000 (0
0 (D (.0
NCAN.t(61-
mN NN
N
0 N a
jn. U)
Rr� N
(A
=
ac)a
v>QOOW(nmom(n
2
N O
Y
=
W
0)N (D co O O O O
(J)
01O O(n
C
O MM 0(0M0 00 O
(D CO O M-
U
N r- O
666
C �r000
m
-
---N M
Z_V
01` 0
N0-
r-MMO
.5 LO t'-
ON NN
W of
Z
C OM
W
V
V
R
L)
W
m0�
LL
W
W
I`O o
a
JUS
Q
t 3 C.
Z
W
~
3 DOS
`� c
a W 0
C c Q. w m m
�=
W
lV CL
0
r-
-00
to O
pa �O-mLL`
0
m
� cc
LL» (ten j C3ollU
C.
Q w 0=
OEE;yo
Qmm0cac
`mmd0=
E3susu
000 O
vo o
V
52
�1%ww U.LLLL
8 (-rL N ZQ a' w QJ J
o ViS_"mZ
C
N
W C)
CL :r
J
U r °)
L _
Z `o Q
20
Q
W
Cl)
O
�co
_ry
Y �m
W
CL m
J OQ
O
U
CD
J EQ
Op
O 1 ''n
Uc0
Y
m
N
CL
O O 100 N MOO O I- o
Oe 0000 000)O 00
00VONNc-0 Nn
a0
Y 0 0000 LO C14 O)O ('
a(°'nm v a(Do U.
N r c= m
0 .- 1L (M
0~ 0<=C
=ju
Y yr 0000 004
IL (n
!it
0? Lu
CL CL
> LU
m m LU C)
° U
`m c .0 U ` 00 ti II
0-0
m(nU �<�� 02 c.0
6,U o L)i mI°
CO a .Y O O O m N 0 "O
(n(nT-C5C53:aLLQscn
W
w°o 0000)vovoo(n N
d O `•'
� F-
CL 0
V
d L 0 0 0 (O (! W'T 0 0 0 r
mBO �OOCO O(D
C. Nm N7� �•N N
In
43)
/n
r e
00,*M lrMMOON �
V 0
J°
zd
C 0)
d r -
0 d N IL m
m 2 (q 32 (Yo l
D. O
(a II
0
d mL
OOI�N
Z0w
OD LD
NOM(D (D
hm
NCAN.t(61-
E-• _�
3J 3
d+ m
FL V1
c
d
rn
A m 3
a+ m
tll
c
d
fn
COOCD 06) O OCD000
000 O OLO 0--000
0006 O (D O � 000
N
-0-0-0-0--Q co O LO Q 00
c_;r k �J tc
ccs C)
r„_ C
N > > =) K
0 0 3 F- C
U u.
0. UJ ccO
M, rn qtr
O m 00m U)m 0 m—
J U) JOS Lw )
l4 L a0) R L .0 to d N O
5 0>QOW094
C14(DO N NO O O
O O O
O O O
O O �
0
W
H-
Z
W
U N
Lo
M
W
CLtm
m
2 m II
QJ II
(j Q w
L
'00 a G
cn (9
O
0.
O
O O N o M O O O M
(O N 00
O N CO O
V
�00(D d' OM O 0000000 O
•- N O
O
O
0400�! CO7 O� O OOLLID 0
R O N r M O O
(6 v cli V7 t- ao
U)
Oo1-00LO O � �ooU) 00
N (D N N (A
N - M r
000000V OOV O MON 0 000 O
CV NO(DO (D rON cc (A
Oi N CM r (D M LO Iq M C\j
N 'DC
"O O
m a U `0 0 l
-1OO O -0C) C 11
C_UU Ol00 O� +2
G.0
O 43) d U N N U 'c a,
N L) = '- O .m -
d a x 0 m m m 0 " a
Wc„n(„i)IYOc�c��a(iQ c)
1v OO O Cl)
Cl)LO
O)
N
N
V
0)LL
C.
00
J°
zd
C 0)
U) n
0 d N IL m
m 2 (q 32 (Yo l
00
(a II
0
-0J to > Cip� mY Q
m R O N O= 4) CL 3
r
II
I- 3,g
Uou
O L
00
E La
Ew Q 3 LL m a
O N 0 0� M cv
0 N a
jn. U)
m
d m> x = 0 3c =
=
�
ac)a
v>QOOW(nmom(n
O
0)LL
N O O
00
J°
00 O60
ZIC oL
0)0 O
00
p
coO O
00
I- 3,g
Uou
InO o
-
00
J .-
W R
O N 0 0� M cv
J
Ci
N
WQ_
N
N O
L
C7
J
m
L o L,�_ p
OS OI—y. O
0.-
voo
oov
a�
666
00 v
m
OO O
Z_V
O O
J
W of
to 0
W
=
2 m
C x L
0 0
� w
Uu
N
�QaL
m0�
Q
O N O
N
0)
LOO O
—o O
OCA O
-o 0
v
RLL
NO O
d
W R
O N 0 0� M cv
J
Cc� Lf) a) 00
N
Q
N
o
L
C7
Lo 0
0
L o L,�_ p
OS OI—y. O
LL
r` 0 0
I�a r-wW°3 w
Sa
u-)0 0
0)
LOO O
—o O
pQpLL
o°
-o 0
RLL
NO O
d
Ili
( O O
J
Q
CD O O
_ 0)
coNO O
LL
r` 0 0
Zm°
O 0
�O O
CO
L
V=LL
OO O
W W
O O
J
W of
to 0
Cl) CE U
J Q
Ci
Uu
U' a�
I`O o
JUS
"T O
Ow
c
OC
Uy
L
�
2
-00
to O
0
0
m
C.
m
U
m C
000 O
vo o
tl0
v
52
VU >
(0
�Q O
(0—
O 0
N
O
O p)
p IL
O a
a x
Lo N
O U)
76
v r
m U
m E
0 4)
U >•
M _
i
O N
C) •�
r- m
LLj4® w
LL
H
U
U
N m
E m
O
Z Z
U N
O N
m
o m
a o
n
YORK
9761
SUBMITTAL DATA
For: Quotation
Order #: Date: 12/04/2015
Project: UNIVERSAL BUILDING SYSTEMS
Project #: RWS12042015-04
Location: WASHINGTON
Purchaser: WILLIAMS MECH-BILL
Submitter: YORK NW -RYAN
ti ,HEWED FOR
,,UDE COMPLIAN,
APPROVED
MAR 2 2 2016
city Qf TukwiLa.
ILOING DIVISIOn,
RECEIVED
CITY OF TUKWILA
MAR 0 3 2016
PERMIT CENTER
Mlle 00'h7
Unitary Sales Tool 0.5.9.0 Information is subject to change without notice. Check local codes. Printed 12/04/2015
Date
12/04/2015
Project Name romyo
UNIVERSAL BUILDING SYSTEMS
Project Number
RWS12042015-04
Client / Purchaser
WILLIAMS MECH-BILL
Submittal Summary Page
Qty Tag # Model # Description
1 ZF060N10A2AAA4 5 Ton, York Sunline Single Packaged R-41 OA Air Conditioner, 13.0
SEER / 10.8 EER, Single Stage Cooling, 100 MBH Output
Aluminized Steel, Single Stage Gas Heat, 1 HP Direct Drive Blower,
1" Throwaway Filters, 208/230-3-60, Microchannel Condenser Coil,
Simplicity Lite Control, Galvanized Steel Drain Pan
1 1 RC0434 Roof Curb - 14" High, Flat, Uninsulated, Full Perimeter (Shipped
Knocked Down)
1 2EE04709224 Single Enthalpy Low Leak Jade Downflow or Horizontal Economizer
w/o Barometric Relief
1 1 RD0410 Barometric Relief Damper with Hood Kit (Downflow Unit or Duct
Mounted)
Equipment start-up and commissioning by a factory trained technician is recommended.
Contact your supplying distributor or sales representative for additional information & guidance.
Unitary Sales Tool 0.5.9.0 Information is subject to change without notice. Check local codes. Printed 12/04/2015
imyoRK
Project Name: UNIVERSAL BUILDING SYSTEMS
Quantity: 1
mall Sunline
Single Package R -410A Air Conditioner
L,00nn rerrormance
Total capacity
59.8 MBH
Sensible capacity
45.3 MBH
Refrigerant type
R-41 OA
Seasonal Efficiency (at ARI)
13.00 SEER
Efficiency (at ARI)
10.80 EER
Ambient DB temp.
95.0 °F
Entering DB temp.
80.0 °F
Entering WB temp.
67.0 °F
Leaving DB temp.
59.0 °F
Leaving WB temp.
57.6 °F
Power input (w/o blower)
4.54 kW
Sound power
82 dB(A)
Gas Heating Performance
Entering DB temp.
60 °F
Heating output capacity (Max)
100 MBH
Supply air
2000 CFM
Heating input capacity (Max)
125 MBH
Leaving DB temp.
106.3 °F
Air temp. rise
46.3 °F
SSE
80.6 %
Stages
1
Supply Air Blower Performance
Supply air
2000 CFM
Ext. static pressure
0.6 IWG
Addl. Unit Losses (Options/Accessories)
0.15 IWG
Blower speed
1103 RPM
Duct location
Bottom
Motor rating
1.00 HP
Actual required BHP
1.02 HP
Power input
0.95 kW
Elevation
0 ft.
Drive type
DIRECT
Speed tap
5
Electrical Data
Power supply
230-3-60
Unit min circuit ampacity
27.5 Amps
Unit max over -current protection
35 Amps
Dimensions & Weight
Hgt 33 in. Len 83 in. Wth
45 in.
Weight with factory installed options
644 lbs.
Clearances
Right 24 in. Front 32 in. Back
36 in.
Tnn 79 i Rn4fnm n i I o4
4R ;
Note: Please refer to the tech guide for listed maximum static pressures
c usw".� N
Unit Model #: ZF060N10A2AAA41
System: ZF060N10A2AAA4 1
5 Ton
• York Units are Manufactured at an ISO 9001 Registered Facility and Each
Rooftop is Completely Computer -Run Tested Prior to Shipment.
Unit Features
• Unit Cabinet Constructed of Powder Painted Steel, Certified At 1000 Hours
Salt Spray Test (ASTM B-117 Standards)
• Through -the -Curb and Through -The -Base Utility Connections
• Either Supply and/or Return can be Field Converted from Vertical to
Horizontal Configuration without Cutting Panels.
• Full Perimeter Base Rails with Built in Rigging Capabilities
• Galvanized Steel Drain Pan
• Single Stage Cooling
• Solid Core Liquid Line Filter Driers
• Microchannel Condenser Coil
• 100 MBH Output Aluminized Steel, Single Stage Gas Nominal Heat
• 1 HP Direct Drive Blower
• Unit Ships with 1" Throwaway Filters with a Standard Filter Rack That Will
Accept up to 2" Filters
• Replacement Filters: 2 - (15' x 20" x 1" or 2") and 1 - (14" x 25" x 1" or 2").
Unit accepts 1" or 2" wide filters.
• Single Point Power Connection
• Short Circuit Current: 5kA RMS Symmetrical
Standard Unit Controller: Simplicity Control Board
• An Integrated Low -Ambient Control, Anti -Short Cycle Protection, Lead -Lag,
Fan On and Fan off Delays, Low Voltage Protection, On -Board Diagnostic
and Fault Code Display. Allows all units to operate in the cooling mode down
to 0 °F outdoor ambient without additional components or intervention.
• Safety Monitoring - Monitors the High and Low -Pressure Switches, the
Freezestats, the Gas Valve, if Applicable, and the Temperature Limit Switch
on Gas and Electric Heat Units. The Unit Control Board will Alarm on Ignition
Failures, Safety Lockouts and Repeated Limit Switch Trips.
Warranty
• One (1) Year Limited Warranty on the Complete Unit
• Five (5) Year Warranty - Compressors and Electric Heater Elements
• Ten (10) Year Warranty - Aluminized Steel Tubular Heat Exchangers
Unitary Sales Tool 0.5.9.0 Information is subject to change without notice. Check local codes. Printed 12/04/2015
91211111111111yox
Small Sunline Page:4
w R
Single Package R-410A Air Conditioner
Project Name: UNIVERSAL BUILDING SYSTEMS Unit Model #: ZF060N10A2AAA4
Quantity: 1 System: ZF060N10A2AAA4
Factory Installed Options
ZF060N10A2AAA4
Product Category:
Z
York Sunline Single Packaged R-41 OA Air Conditioner
Product Identifier:
F
13.0 SEER / 10.8 EER
Nominal Cooling Capacity:
060
5 Ton
Single Stage Cooling
Heat Type and Nominal Heat Capacity:
N10
100 MBH Output Aluminized Steel, Single Stage Gas
Heat
Airflow:
A
1 HP Direct Drive Blower
1" Throwaway Filters
2
Voltage:
208/230-3-60
Installation Options:A
Microchannel Condenser Coil
Additional Options:
AA
Simplicity Lite Control
Galvanized Steel Drain Pan
Product Generation: 4
Field Installed Accessories
1 RC0434 - Roof Curb - 14" High,
Flat, Uninsulated, Full Perimeter
(Shipped Knocked Down) (86.0
lbs)
2EE04709224 - Single Enthalpy
Low Leak Jade Downflow or
Horizontal Economizer w/o
Barometric Relief (50.0 lbs)
1 RD0410 - Barometric Relief
Damper with Hood Kit (Downflow
Unit or Duct Mounted) (6.0 lbs)
Unitary Sales Tool 0.5.9.0 Information is subject to change without notice. Check local codes. Printed 12/04/2015
L
vle
a
s
r ^ ^^^^^^
M m M p p V m a O O p m O O m m
�� m -w�H
4.
N
N
rn m rn m ,.,� In In ao rn rn rn n n
m y
_
Z
Z
M m m m V1 1� n m N N 111 1� Ol Ol m m
O
O
^� N
m
LL
LL
v
'.I in H ry n rn in in in m m n In
.-+ '-I H .--I H '-I H .--I H .-I e -i .ti H H .•-I H
.ti c -I
'—'
-
a
z
N
N
o
77w
off
Q
_
1p m m M M Ill l�
n
H
N Mo
r
O
u r
l0 M lD lD n m--
0
O
N
>,
Z
�
-
m m H N N N H H .--I N N N
.� .� n m m rn .� .� .� .� .-� H H .� .�
W
H z
> H
w
cc
¢
m^
to
m^ >
.-I rn m v m vl m ry v In m In ry v, ry m
M H m m H m M M M M M M M M
oo �p
I^ M d O
m Ol
.--I - .--I .--I .--i .--I .--I .--i .--i H - .--I .-+ .--I .-I .--I
w
�
r
w
O
r
N H m m m� m m m
x
1p 1p �p 1p '•i n�
n
V u � V R M M lmll lmll Ilml � � lmn � lmll
}
u u u u u �
Q
Q N
-
ry m N N Imn ^ V
co m mm
m
. -I .=I
OHO OHO m m .m -I ~
VI
m N
Z
H
^
t2I�
Ift �
T
yZj V
VOX
m .-I M m M m m m m Ol O^l Ol
M
m m H m M M M M M
M
O
j
Y
Z
m
^ p
H v Z
p
I --I n m H cf In ml0 l0 1p 1� n m l0 l0 l0
w
N N N N N N N N N N N N N N N N
.--� O
C)
Qr
x
M
V
w M Vl
d Q
A m
m m N m H Ol m 111 Vl m m l0 m In to
1� Ol M l0 l0 I� m Ol H H N 1� Ol
x
d
O 3 m
a en l0 a In to 1p IA IA vl 1p lD l0 Vl In In
t�-I
m J 00
z
C
H
LL C C C Z Z Z d d d
9 w m
J•dO
OZHr
N N N N N N N N N N X X X X X X
CQ J a
�a
o
_ w r 0
O
Z
M 'Q Vl M �' Vl 1p M V N M S
T -MM--
n
V
�
�z a m
�v
v�
C,Rt
w u' v u3i
JN>
O �u
L
VU >
Q
C3�
du
d r
m�
N
Q:
•O
lD u
N N H u
aWV Ql �
(((//�����
I
L �T
�Sa ry m
Y
v+
IL
^N
M
D
3w
Qi
Nm
rnmm
m
MlO
u
C
V!
rOV
mQ
a
p
�
V
m
} m
Hu
a
yHjm
�Om
W� N O
N
Cl N
m
In(S.
O
�m �� vC,
WO
Om Z m
¢
Z O
2 O O
O Y r+t
O
U)w
• Vl H �
3
N .--I
r
W
a LL^ wzi��mvi 'Col C)
PIS
p
N
YOCZ
V
N
^ V ^Od sQONrI=J -
.§�
CO)
tr-I
w w ¢ z z Q w d r O W lx -9 m (D- Q
O
Z_
NNr NN pppdOH J
Yu
�1�
V
�2:: Ow
Z
J
OOJ OON ZV Vl ^ 2 ZJ
^
Z
ZZW^z ZH al--Iap }N v1 rOr
zsrwwz •. VO
m^
J
O
l:J
U0,<Uum
WWV•QV VO OWrroC0 NV1r NWO
�wwwr Hw QZQV1Nw2
2 O rZ J VIS--t�l."J
N
H
H
�
to -
3W mu Old
OV I-I,J
H
NxJ V12i QHw Ovlw ZH �HtJ
Z
Ia3.I
V H
ma
C)
O
l2 LIS s�mfrV= aw az
HoawHoc z tJtJvlJx -www
JavvJ VH dwoln�a
... a^ C) F "mcn
>
w
J
Q
Zoo af=Zlnuz.,
m poprwom>za a>z
iD
o
d
s
z� �,
..
Cw
lO �iD aOmV •. ZHwH2 Qrr wV' Z3
m Qr ZZrw w2 v1C 00
}
K
Hy�j HrZ
W
JOm
z olo
OI GTVOlN�7 N QI:JJ ZC Z Q U2
mm Hm.-ImH mru�UH HO QrOw p Vl
.orn�mmrn m�,Hv,Wap
r
w
N
U p OILLQ
Z
oc
N Qw
�ZV
>dp rvlw ar opo
Vd'lOVNrvm Nmd'd Q' -M-3 -4Jr0
NNMNM.--IM 1� QN}p ZpWW Hx
tx r — ^Q ZJ3
d
X
p
Z
O
O
O^
=.:z
d
n p
m
3z
d'OQw••
•• oCVZp VI J InpZ HHVt
WOO-wVuIirz
O
C, a[�p
J}pfQ rJOV trn ZV VZ
X
w W
NO
CC
t�
p
rV1J
V1H •• VO OJ wH
Vl 7::C,=C. r00m0
r
H
��
N
OrUr
ox
r •• OVJUw pf JO V1Z Zr
xr z s ••Anal,_ In oEJzoow
d
p �+
p0
z�-
�u
Z
�%,
CIS-IIZ
pWHOCJ
I�-Iw C w OOCZ30mO pI Fl-t�nP
oC r m 0000V1 CCH OHx H d H C
V
w
C
3E
SM -3 l4 pOpO
�mn
O
D
tL
r.HNM
C m01
®
��
j
CL
/ryY
l•,/
Z
O
N �
Small Sunline Page:6
MYORK Single Package R-410A Air Conditioner
Project Name: UNIVERSAL BUILDING SYSTEMS Unit Model #: ZF060N10A2AAA4
Quantity: 1 System: ZF060N10A2AAA4
FIELD -SUPPLIED
DISCONNECT SWITCH
JD
Unitary Sales Tool 0.5.9.0 Information is subject to change without notice. Check local codes. Printed 12/04/2015
Small Sunline
Single Package R -410A Air Conditioner
Page: 7
Project Name: UNIVERSAL BUILDING SYSTEMS Unit Model #: Z1F060N10A2AAA4I
Quantity: 1 System: ZF060N10A2AAA4
TYPICAL POWER WIRING
CONTACTOR
FIELD -SUPPLIED
DISCONNECT
— I � SINGLE
1------------I--O-'''¢ r- PHASE
L---------------J--0-'I"0--{ >POWER
GROUND L - - - - - - - SUPPLY
LUG
REFER TO THE ELECTRICAL DATA
TABLES TO SIZE THE DISCONNECT
SWITCH. OVER CURRENT
PROTECTION AND WIRING.
CONTACTOR
0 FIELD -SUPPLIED
DISCONNECT
r -- - --
'------ - - - -i- O `+ S3 -r- THREE
L------------I--O•'€"f}-I PHASE
GROUND L---,-----------J--0--Lo--L `] POWER
LUG SUPPLY
TYPICAL COOL/HEAT CONTROL WIRING
COOLING ONLY (24 VOLT THERMOSTAT) COOLING 1 HEATING (24 VOLT THERMOSTAT)
THERMOSTAT' UNIT TERMINAL
TERMINALS STRIPTBI
24 VOLT
Y1 TRANSFORMER
6
O
124 VOLT THERMOSTAT, TO CONTROL THE ECONOMIZER ON SECOND
STAGE COOLING. USE A 2 STAGE COOLING THERMOSTAT.
COOLING / HEATING (ELECTRONIC THERMOSTAT)
MULTI STAGE
UNIT TERMINAL
STRIP TB1 24 VOLT
---- - R TRANSFORMER
Y1
-- Y2
•------ W1
------ W2
TO REMOTE SENSOR
IF USED
' ELECTRONIC PROGRAMMABLE THERMOSTAT TYPICAL.
' SECOND STAGE COOLING IS NOT REQUIRED ON UNITS LESS ECONOMIZER.
a SECOND STAGE HEATING IS ONLY REQUIRED ON UNITS WITH A TWO STAGE
ELECTRIC HEATER OR 2 STAGE GAS HEAT.
. REMOVE JUMPER J2 FROM TERMINALS 4 AND 9 ON JUMPER PLUG CONNECTOR
P6 ON UNITS WITH ECONOMIZER, TERMINALS Al AND A2 PROVIDE A RELAY
OUT -PUT TO CLOSE THE OUTDOOR ECONOMIZER DAMPERS WHEN THE
THERMOSTAT SWITCHES TO THE SET -BACK POSITION.
THERMOSTAT'
TERMINALS
ADD —
JUMPER
UNIT TERMINAL
STRIP TB1
•••. • R
24 VOLT
TRANSFORMER
Y2
W2
'24 VOLT THERMOSTAT, TO CONTROL THE ECONOMIZER ON THE SECOND
STAGE COOLING OR TO HAVE AN ELECTRIC HEAT ACCESSORY WITH TWO
STAGES OF HEAT, USE A 2 STAGE COOL AND HEAT THERMOSTAT.
COOLING / HEATING (ELECTRONIC THERMOSTAT)
SINGLE STAGE
THERMOSTAT'
TERMINALS UNITTERMINAL
RH STRIP TB1
RC--__-- ---- -------- R
ADD
JUMPER Y -------------------- Y1
G----•----•---------- G
C
24 VOLT
TRANSFORMER
' ELECTRONIC PROGRAMMABLE THERMOSTAT TYPICAL. TO CONTROL THE
ECONOMIZER ON SECOND STAGE COOLING, USE A 2 STAGE COOL AND
HEAT THERMOSTAT.
unitary oases iooi vi.o.a.0 intormation is suolect to cnange witnout notice. Check local codes. Printed 12/04/2015
THERMOSTAT1
TERMINALS
ADD
RC
JUMPER
RH
---'--
Y1
-----
Y2
-------- 2
W1--------------
4
W2
-- 3
G
B------------
LED 1
--------•----
LED2
NOT
COM
USED 4
ADD
Al
- —
JUMPER
A2
UNIT TERMINAL
STRIP TB1 24 VOLT
---- - R TRANSFORMER
Y1
-- Y2
•------ W1
------ W2
TO REMOTE SENSOR
IF USED
' ELECTRONIC PROGRAMMABLE THERMOSTAT TYPICAL.
' SECOND STAGE COOLING IS NOT REQUIRED ON UNITS LESS ECONOMIZER.
a SECOND STAGE HEATING IS ONLY REQUIRED ON UNITS WITH A TWO STAGE
ELECTRIC HEATER OR 2 STAGE GAS HEAT.
. REMOVE JUMPER J2 FROM TERMINALS 4 AND 9 ON JUMPER PLUG CONNECTOR
P6 ON UNITS WITH ECONOMIZER, TERMINALS Al AND A2 PROVIDE A RELAY
OUT -PUT TO CLOSE THE OUTDOOR ECONOMIZER DAMPERS WHEN THE
THERMOSTAT SWITCHES TO THE SET -BACK POSITION.
THERMOSTAT'
TERMINALS
ADD —
JUMPER
UNIT TERMINAL
STRIP TB1
•••. • R
24 VOLT
TRANSFORMER
Y2
W2
'24 VOLT THERMOSTAT, TO CONTROL THE ECONOMIZER ON THE SECOND
STAGE COOLING OR TO HAVE AN ELECTRIC HEAT ACCESSORY WITH TWO
STAGES OF HEAT, USE A 2 STAGE COOL AND HEAT THERMOSTAT.
COOLING / HEATING (ELECTRONIC THERMOSTAT)
SINGLE STAGE
THERMOSTAT'
TERMINALS UNITTERMINAL
RH STRIP TB1
RC--__-- ---- -------- R
ADD
JUMPER Y -------------------- Y1
G----•----•---------- G
C
24 VOLT
TRANSFORMER
' ELECTRONIC PROGRAMMABLE THERMOSTAT TYPICAL. TO CONTROL THE
ECONOMIZER ON SECOND STAGE COOLING, USE A 2 STAGE COOL AND
HEAT THERMOSTAT.
unitary oases iooi vi.o.a.0 intormation is suolect to cnange witnout notice. Check local codes. Printed 12/04/2015
Small Sunline Page:8
MYORK Single Package R -410A Air Conditioner
Project Name: UNIVERSAL BUILDING SYSTEMS Unit Model #: ZF060N10A2AAA4I
Quantity: 1 System: ZF060N10A2AAA4
on
SPECIAL SEISMIC CERTIFICATION
OF NON-STRUCTURAL
COMPONENTS AND SYSTEMS
CERTIFICATE OF COMPLIANCE
Johnson
Controls
Dynamic Certification Laboratories has qualified the listed packaged rooftop units as CERTIFIED for seismic
applications in accordance with the following codes and standards:
CBC 2010, IBC 2009, ICC -ES AC -156 2010, ASCE 7-05
The following model designations are included in this certification. A complete list of certified models, options,
and installation methods are detailed in report number 90300-1108a by Dynamic Certification Laboratories,
provided by the equipment manufacturer upon request.
Unitary Product Group Packaged Rooftop Units (UPG)
Seismic Qualification Testing was conducted in accordance with and in strict adherence to the standards set
forth within the American Society of Civil Engineers (ASCE 7) by the independent approval agency, Dynamic
Certification Laboratories. The above referenced equipment is APPROVED for seismic applications when
properly installed and used as intended.
The basis of this certification is through testing of the active and energized components per AC156. This
certification covers multiple UPG brands, including York, Johnson Controls, Coleman, Luxaire, Evcon and Fraser -
Johnston.
The seismic values are obtained from the Maximum Considered Earthquake Short Period Spectral Response
Acceleration, Sds, as determined by the ASCE 7 seismic maps. Various installation locations/isolation
configurations are covered under this certification, limited by the Sds value stated in the following table. A
seismic importance factor, Ip, of 1.5 applies to this certification to include essential facility requirements and life
safety applications for post event functionality. The units are approved for both a rigid and flexible mount
configuration.
Maximum Design Sds Values of UPG Packaged Rooftop Units
Series
Model
Tons I Sds (g)
Fp/Wp
XP/XA/10*XP/TO*
036, 048, 060
3--,4,5 2.5
1.88
ZF/ZS/JO*ZF/JA*ZF/TO*
036, 048, 060, 072
3, 4, 5, 6 2.5
1.88
ZR/ZK/JO*ZR/TO*
036, 048, 060
3, 4, 5 2.5
1.88
Page 1 of 2
Dynamic Certification Laboratories 1315 Greg Street, Suite 109, Sparks, NV 89431— ph: 775-358-5085 www.shaketest.com
Unitary Sales Tool 0.5.9.0 Information is subject to change without notice. Check local codes. - Printed 12/04/2015
W1112MY0Small SunlineRK Page:9
Single Package R -410A Air Conditioner
LProject Name: UNIVERSAL BUILDING SYSTEMS Unit Model #: ZF060N10A2AAA4I
Quantity: 1 System: ZF060N10A2AAA4
SPECIAL SEISMIC CERTIFICATION
(( v)) DIOL, OF NON-STRUCTURAL
COMPONENTS AND SYSTEMS
CERTIFICATE OF COMPLIANCE
1#�
Johnson ,+ t,
Controls
Table of Seismic Design Parameters
Site Class
Fa
Ip
a
R
z/h
D
1.0
1.5
2.5
6.0
1.0
Site and Project Requirements
It is the responsibility of the Design Professional of Record to:
• Provide engineering for the anchorage and restraint of the unit
• Validate Cerftficafton Design Parameters with actual site condiftons
• Provide engineering of all equipment support structures
• Confirm component configurafton
Cerftficafton Issued by: Dynamic Cerftficafton Laboratories
Document Control Number: 90300-1108a-1
Issue Date: 12/19/11
Dr. Ahmad Itani, SE
Dynamic Cerftficafton Laboratories
Randy Forristall
YORK Unitary Engineering
Johnson Controls, Incorporated
Page 2 of 2
Dynamic Cerftficafton Laboratories 1315 Greg Street, Suite 109, Sparks, NV 89431— ph: 775-358-5085 www.shaketest.com
Unitary Sales Tool 0.5.9.0 Information is subject to change without notice. Check local codes. Printed 12/04/2015
02�yoSmall SunlineRK Page: 10
Single Package R-41 OA Air Conditioner
Project Name: UNIVERSAL BUILDING SYSTEMS Unit Model #: ZF060N1OA2AAA4
Quantity: 1 System: ZF060N10A2AAA4
DUCT SIZES:
Supply Air = 19" x 19"
Return Air= 19" x 19"
1RC0434 Roof Curb Dimensions
Supply and Return Air (including duct support rails)
shown are typical for bottom duct applications.
For location of horizontal duct applications
(on back of unit), refer to Unit Dimensions details.
nitary Sales Tool 0.5.9.0 Information is subject to change without notice. Check local codes. Printed 12/04/2015
Date
12/04/2015
Project Name
UNIVERSAL BUILDING SYSTEMS
Project Number YORK
RWS12042015-04
Client / Purchaser
WILLIAMS MECH-BILL
Guide Specification Summary Page
Product Series Models and Unit Tags
Small Sunline F�60110A2AAA4
i,
Unitary Sales Tool 0.5.9.0 Information is subject to change without notice. Check local codes. Printed 12/04/2015
Guide Specification for Page: 12
MYORK York Sunline
GENERAL
Units shall be manufactured by Johnson Controls Unitary
Products in an ISO 9001 certified facility. York Sunline
units are convertible single package units. Although the
units are primarily designed for curb mounting on a roof,
they can also be slab -mounted at ground level or set on
steel beams above a finished roof. Cooling only, cooling
with gas heat and cooling with electric heat models are
available with a wide variety of factory -mounted options
and field -installed accessories to make them suitable for
almost every application. All units are self-contained and
assembled on full perimeter base rails with holes in the
four corners for overhead rigging. Every unit is
completely piped, wired, charged and tested at the
factory to simplify the field installation and to provide
years of dependable operation. All models (including
those with an economizer) are suitable for either bottom
or horizontal duct connections. Models with power
exhaust are suitable for bottom duct connections only.
For bottom duct, remove the sheet metal panels from the
supply and return air openings through the base of the
unit. For horizontal duct, remove the supply and return
air panels on the rear of the unit.
All non -Scroll compressors include crankcase heaters and
all compressors have internal pressure relief. Every
refrigerant circuit includes a liquid line filter -drier, a
discharge line high pressure switch and a suction line with
a freezestat and low pressure/loss of charge switch. The
unit control circuit includes a 75 VA transformer, a 24 -volt
circuit breaker and a relay board with a compressor
lockout circuit, a terminal strip for thermostat wiring, plus
an additional set of pin connectors to simplify the interface
of additional field controls. All models are CSA listed. All
models include a 1 -year limited warranty on the complete
unit. Compressors and electric heater elements carry a 5 -
year warranty. Aluminized steel and Stainless steel tubular
heat exchangers carry a 10 -year warranty.
DESCRIPTION
Units shall be factory -assembled, single packaged,
Electric Cooling/Gas Heat, Electric Cooling/Optional
Electric Heat, Heat Pump/Optional Electric Heat are
designed for outdoor mounted installation.
The 3 ton, 4 ton and 5 ton units shall have minimum SEER
rating of 13.0 with heat pumps having a 7.7 H.S.P.F. The 6
Ton Cooling only or Cooling with Electric Heat shall have
11.2 EER, 6 Ton Cooling with Gas Heat shall have 11.0
EER. They shall have built-in field convertible duct
connections for down discharge supply/return or horizontal
discharge supply/return, and be available with factory
installed options or field installed accessories. The units
shall be factory wired, piped, charged with R-41 OA
refrigerant and factory tested prior to shipment. All unit
wiring shall be both numbered and color coded. All units
the cooling performance shall be rated in accordance with
DOE and AHRI test procedures. Units shall be CSA listed,
classified to ANSI Z21.47, UL 1995/CSA No. 236
standards.
UNIT CABINET
Unit cabinet shall be constructed of galvanized steel, with
exterior surfaces coated with a non -chalking, powdered
paint finish, certified at 1000 hours salt spray test per
ASTMB117 standards. Indoor blower section shall be
insulated with a minimum 1/2" thick insulation, coated on
the airside. Aluminum foil faced insulation shall be used in
the furnace compartment and be fastened with ridged
fasteners to prevent insulation from entering the air
stream. Cabinet panels shall be "large" size, easily
removable for servicing and maintenance. Full perimeter
base rails shall be provided to assure reliable transit of
equipment, overhead rigging and proper sealing on roof
curb applications. Disposable 1" filters shall be furnished
and be accessible through a removable access door,
sealed airtight. Units filter track shall be designed to
accommodate either 1" or 2" filters. Fan performance
measuring ports shall be provided on the outside of the
cabinet to allow accurate air measurements of evaporator
fan performance without removing panels or creating air
by-pass of the coils. Condensate pan shall be internally
sloped and conform to ASHRAE 62-89 self -draining
standards. Condensate connection shall be a minimum of
3/4" I.D. female and be a ridged mount connection.
INDOOR (EVAPORATOR) FAN ASSEMBLY
The indoor fan shall be a factory installed direct -drive or
belt -drive assembly that includes an adjustable pitch motor
pulley. Job site selected (B.H.P.) brake horsepower shall
not exceed the motors nameplate horsepower rating, plus
the service factor. Units shall be designed not to operate
above service factor. Fan wheel shall be double -inlet type
with forward -curved blades, dynamically balanced to
operate smoothly throughout the entire range of operation.
Airflow design shall be constant air volume. Bearings shall
be sealed and permanently lubricated for longer life and
no maintenance.
OUTDOOR (CONDENSER) FAN ASSEMBLY
The outdoor fan shall be of the direct -driven propeller type,
discharge air vertically, have aluminum blades riveted to a
corrosion resistant steel spider bracket and shall be
dynamically balanced for smooth operation. The outdoor
fan motor shall be totally enclosed with permanently
lubricated bearings, internally protected against overload
conditions and staged independently.
Unitary Sales Tool v1.5.9.0 Information is subject to change without notice. Check local codes. Printed 12/04/2015
Guide Specification for Page: 13
MYORK York Sunline
REFRIGERANT COMPONENTS
Compressors:
a. Shall be internally protected with internal high-
pressure relief and over temperature protection.
b. Shall have internal spring isolation and sound
muffling to minimize vibration and noise, and be
externally isolated on a dedicated, independent
mounting.
Coils:
a. Evaporator coils shall have aluminum plate fins
mechanically bonded to seamless internally
enhanced copper tubes with all joints brazed. Special
Phenolic coating shall be available as a factory
option.
b. Evaporator coils shall be of the direct expansion,
draw-thru design.
c. Condenser coils shall have aluminum plate fins
mechanically bonded to seamless internally
enhanced copper tubes with all joints brazed or
Micro -Channel aluminum tube, aluminum fins.
d. Condenser coils shall be of the direct expansion,
draw-thru design.
Refrigerant Circuit and Refrigerant Safety Components
shall include:
a. Independent fixed -orifice or thermally operated
expansion devices.
b. Filter drier/strainer to eliminate any moisture or
foreign matter.
c. Accessible service gage connections on both suction
and liquid lines to charge, evacuate, and measure
refrigerant pressure during any necessary servicing
or troubleshooting, without losing charge.
d. The refrigeration system shall provide at least 15°F of
sub -cooling at design conditions.
Unit Controls:
a. Unit shall be complete with self-contained low -voltage
control circuit protected by a resettable circuit breaker
on the 24 -volt transformer side.
b. Unit shall incorporate a lockout circuit which provides
reset capability at the space thermostat or base unit,
should any of the following standard safety devices
trip and shut off compressor.
c. Loss-of-charge/Low-pressure switch.
d. High-pressure switch.
e. Freeze -protection thermostat, evaporator coil.
f. Unit shall incorporate "AUTO RESET" compressor
over temperature, over current protection.
g. Unit shall operate with conventional thermostat
designs and have a low voltage terminal strip for
easy hook-up.
h. Unit control board shall have on -board diagnostics
and fault code display.
i. Standard controls shall include anti -short cycle and
low voltage protection, and permit cooling operation
down to 0°F.
j. Control board shall monitor each refrigerant safety
switch independently.
k. Control board shall retain last 5 fault codes in non
volatile memory which will not be lost in the event of a
power loss.
GAS HEATING SECTION (SINGLE STAGE)
Shall be designed with induced draft combustion with
post purge logic, energy saving direct spark ignition, and
redundant main gas valve. Venter wheel shall be
constructed of stainless steel for corrosion resistance.
The heat exchanger shall be of the tubular type,
constructed of T1-40 aluminized steel for corrosion
resistance and allowing minimum mixed air entering
temperature of 25°F. Burners shall be of the inshot type,
constructed of aluminum coated steel and contain air
mixture adjustments. All gas piping shall enter the unit
cabinet at a single location through either the side or
curb without any field modifications. Integrated control
boards shall provide timed control of evaporator fan
functioning and burner ignition. Heating section shall be
provided with the following minimum protection.
a. Primary and auxiliary high-temperature limit switches.
b. Induced draft motor speed sensor.
c. Flame roll out switch.
d. Flame proving controls.
e. If any of the above safety devices trip, a LED (light -
emitting diode) indicator shall flash a diagnostic code
that indicates which safety switch has tripped.
NOTE: All 2 Stage Gas Heat, 60% Capacity 1st Stage,
40% Capacity 2nd Stage.
UNIT OPERATING CHARACTERISTICS
Unit shall be capable of starting and running at 125°F
outdoor temperature, exceeding maximum load criteria
of AHRI Standard 210/240. The compressor, with
standard controls, shall be capable of operation down to
0°F outdoor temperature. Unit shall be provided with fan
time delay to prevent cold air delivery before heat
exchanger warms up (Gas heat only).
unitary Sales loos v1.b.u.0 Information is subject to change without notice. Check local codes. Printed 12/04/2015
Guide Specification for Page: 14
i3YORK York Sunline
ELECTRICAL REQUIREMENTS
All unit power wiring shall enter unit cabinet at a single
factory provided location and be capable of side or
bottom entry, to minimize roof penetrations and avoid
unit field modifications. Separate side and bottom
openings shall be provided for the control wiring.
STANDARD LIMITED WARRANTIES
• Compressor 5 Years
• Heat Exchanger 10 Years
• Electric Heat Element 5 Years
• Other Parts 1 Year
ADDITIONAL FACTORY INSTALLED OPTIONS
FIELD INSTALLED OPTIONS
• Roof Curb —14" high, full perimeter curb with wood
nailer (shipped knocked -down).
• Barometric Relief Damper — This damper accessory
can be used to relieve internal building air pressure
on units with an economizer without power exhaust.
This accessory includes a rain hood, a bird screen
and a fully assembled damper. With bottom duct
connections, the damper should be mounted over the
opening in the return air panel. With horizontal
ductwork, the accessory should be mounted on the
return air duct.
unitary Sales Tool v1.5.9.0 Information is subject to change without notice. Check local codes. Printed 12/04/2015
PERMIT COORD COPY
PLAN REVIEW/ROUTING SLIP
PERMIT NUMBER: M16-0033 DATE: 03/04/16
PROJECT NAME: T BAR CONSTRUCTION
SITE ADDRESS: 14590 INTERURBAN AVE S
X Original Plan Submittal
Response to Correction Letter #
DEPARTMENTS:
P(i O(WG I ll
Building Divisi n
Public Works ❑
PRELIMINARY REVIEW:
Not Applicable ❑
(no approvallreview required)
REVIEWER'S INITIALS:
APPROVALS OR CORRECTIONS:
Approved ❑
Corrections Required ❑
(corrections entered in Reviews)
Notation:
REVIEWER'S INITIALS:
Fire Prevention
Revision # before Permit Issued
Revision # after Permit Issued
Planning Division ❑
Structural ❑ Permit Coordinator ❑
DATE: 03/08/16
Structural Review Required ❑
DATE:
DUE DATE: 04/05/16
Approved with Conditions ❑
Denied ❑
(ie: Zoning Issues)
DATE:
Permit Center Use Only
CORRECTION LETTER MAILED:
Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials:
12/18/2013
WILLIAMS MECHANICAL INC --
Hosie Espafiol Contact
Safety & Health Claims & Insurance
4jWashington State Department of
Caber & Industries
WILLIAMS MECHANICAL INC
Owner or tradesperson
Principals
WILLIAMS, BRADLEY PATRICK, PRESIDENT
WILLIAMS, DEBORAH KAY, SECRETARY
WILLIAMS, DEBORAH KAY, TREASURER
WILLIAMS, DEBORAH KAY, AGENT
ZUCCARINI, MICHAEL J, AGENT
(End: 01/01/1980)
Doing business as
WILLIAMS MECHANICAL INC
WA UBI No.
601 413 863
License
3903 SMITH AVE
EVERETT, WA98201-4549
425-303-0828
SNOHOMISH County
Business type
Corporation
Page I of 3
Workplace Rights
Verify the contractor's active registration / license / certification (depending on trade) and any past violations.
Construction Contractor. Active.
Meets current requirements.
License specialties
GENERAL
License no.
WILLIM1088PA
Effective — expiration
10/01 /1992-10/01 /2017
Bond
.................
Merchants Bonding Co (Mutual) $12,000.00
Bond account no.
WA33987
Received by L&I Effective date
09/23/2014 10/01/2014
https:Hsecure.Ini.wa.gov/verify/Detail.aspx?UBI=601413863&LIC=WILLIMIO88PA&SAW= 3/23/2016
GENERAL NOTES
1. POST BUILDING ADDRESS SIGN ON FRONT OF BUILDING AS REQUIRED BY BUILDING OFFICIAL,
COORDINATE WITH ARCHITECT.
2. CONTRACTOR IS SOLELY AND COMPLETELY RESPONSIBLE FOR CONDITIONS OF THE JOB SITE,
INCLUDING SAFETY, PROTECTION OF PROPERTY AND THE LIKE DURING THE PERFORMANCE OF
THE WORK.
3, THE CONTRACTOR IS REQUIRED TO COMPLY WITH ALL APPLICABLE REGULATIONS AND CODES OF
THE GOVERNING AUTHORITIES AND OWNERS.
4. PROVIDE METHODS, MEANS AND FACILITIES REQUIRED TO PREVENT CONTAMINATION OF SOIL,
WATER OR ATMOSPHERE.
5. INSURE MINIMUM INTERFERENCE WITH EXISTING ROADS, STREETS, SIDEWALKS, PARKING
FACILITIES AND ADJACENT FACILITIES. DO NOT CLOSE OR OBSTRUCT WITHOUT PRIOR
APPROVAL.
6. ALL SALVAGE WILL BECOME THE PROPERTY OF THE CONTRACTOR, UNLESS NOTED OTHERWISE
(UNO). PROMPTLY REMOVE FROM SITE AND LEGALLY DISPOSE OF ALL SAID MATERIAL AT
CONTRACTOR'S EXPENSE.
7. DIMENSIONS ARE TO:
- FACE OF MASONRY OR CONCRETE, CENTER LINE OF COLUMNS, FACE OF STUD, OR FACE OF
MULLION UNLESS NOTED OTHERWISE.
- DIMENSIONS INDICATED CLEAR (CLR) ARE TO FINISH FACE.
- DIMENSIONS TO DOOR AND WINDOW OPENINGS ARE ROUGH MASONRY OPENINGS UNO.
- ALL MASONRY DIMENSIONS ARE NOMINAL.
8. SCRIBE GYPSUM BOARD OF WALLS AND PARTITIONS TO IRREGULARITIES OF STRUCTURE OR
DECK ABOVE AND SEAL TIGHTLY AROUND ALL PENETRATIONS.
9. IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO COORDINATE WITH THE OWNER'S WORK
AND/OR SUPPLIED ITEMS THAT ARE "FURNISHED BY THE OWNER AND INSTALLED BY THE
CONTRACTOR" OR "NOT IN CONTRACT" (NIC), BUT ARE ATTACHED TO CONTRACTOR'S WORK.
10. ALL RAMPS TO HAVE MAXIMUM 1:12 SLOPE. RAMPS WITH SLOPE OF 1:20 OR GREATER TO
HAVE HANDRAILS PER WASHINGTON STATE HANDICAP CODE.
11. ALL STAIRS TO HAVE MINIMUM 11" TREADS AND MAXIMUM 7" RISERS, UNO.
12. MINIMUM ROOF SLOPE SHALL BE 1/4"=1'-0".
_ 13. CONTRACTOR IS RESPONSIBLE FOR REVIEWING THE DRAWINGS AND SPECIFICATIONS AND WITH
THE NOTIFICATION OF THE ARCHITECT OF ANY DISCREPENCIES WITHIN THE DOCUMENTS AND THE
SCOPE OF WORK. CONTRACTOR IS RESPONSIBLE TO COORDINATE ANY AND ALL REVISIONS TO
THE DRAWINGS.
14. FIRE EXTINGUISHERS TO BE LOCATED PER FIRE MARSHALL'S DIRECTION. AS REQ'D,
15. ALL ROUGH -INS SHALL BE APPROVED PRIOR TO FRAMING INSPECTION.
16. PROVIDE ONE 2A-10BC FIRE EXTINGUISHER PER 3,000 SQ.FT. OR EACH 75' OF TRAVEL
DISTANCE, AS REQUIRED BY FIRE MARSHALL.
17, EXIT LIGHTING SHALL BE PROVIDED WHEN TWO EXITS ARE REQUIRED, THE EMERGENCY SYSTEM
SHALL BE SUPPLIED BY A SEPARATE SOURCE OF POWER AND HAVE AN EMERGENCY BACK UP
SYSTEM. EXITS SHALL BE ILLUMINATED AT ANY TIME THE BUILDING IS OCCUPIED WITH
EMERGENCY LIGHTING HAVING THE INTENSITY OF NOT LESS THAN 1 FOOT CANDLE AT FLOOR
LEVEL. IBC SECTION 1006.3.
18. EXIT DOORS SHALL BE OPENABLE FROM THE INSIDE WITHOUT THE USE OF A KEY OR ANY
SPECIAL KNOWLEDGE OR EFFORT.
19. EXCEPTION: KEY -LOCKING HARDWARE MAY BE USED ON THE MAIN EXIT WHEN THE MAIN EXIT
CONSISTS OF A SINGLE DOOR OR PAIR OF DOORS IF THERE IS A READILY VISIBLE, DURABLE
SIGN ON OR ADJACENT TO THE DOOR STATING THIS DOOR TO REMAIN UNLOCKED DURING
BUSINESS HOURS." THE SIGN SHALL BE IN LETTERS NO LESS THAN 1 INCH HIGH ON
CONTRASTING BACKGROUND. WHEN LOCKED, THE SINGLE DOOR OR BOTH LEAVES OF A PAIR
OF DOORS MUST BE FREE TO SWING WITHOUT P
THOU OPERATION OF ANY LATCHING DEVICE.
20. TRASH DUMPSTERS AND COMPACTORS SHALL BE PROVIDED WITH RUBBER WHEELS N.I.C.
21. EXTERIOR JOINTS AROUND WINDOWS AND DOOR FRAMES, OPENINGS BETWEEN WALLS AND
FOUNDATIONS, BETWEEN WALLS AND ROOF AND WALL PANELS; OPENINGS AT PENETRATIONS
OF UTILITY SERVICES THROUGH WALLS, FLOORS AND ROOFS; AND ALL OTHER OPENINGS IN
THE BUILDING ENVELOPE SHALL BE SEALED, CAULKED, GASKETED OR WEATHERSTRIPPED TO
LIMIT AIR LEAKAGE.
22. BUILDING INSULATION SHALL BE PROVIDED AS INDICATED IN DWGS. W/ R VALUES PER ENERGY
CALCULATIONS.
23. EVERY HANDICAPPED PARKING SPACE SHALL BE IDENTIFIED BY A SIGN CENTERED ON THE
STALL. THE BOTTOM OF THE SIGN NEEDS TO BE 60 INCHES ABOVE THE PARKING SURFACE, AT
THE HEAD OF THE PARKING SPACE. THE SIGN SHALL INCLUDE THE INTERNATIONAL SYMBOL OF
ACCESS AND THE PHRASE "STATE DISABLED PARKING PERMIT REQUIRED". PROVISION UNDER
SITE DEVELOPMENT PERMIT.
24. THIS DRAWING IS AN INSTRUMENT OF SERVICE ONLY. THE COPYRIGHT TO THIS DRAWING
BELONGS TO THE ARCHITECT. NO PERSON MAY USE THIS DRAWING FOR ANY PURPOSE OTHER
THAN THE INTENDED ORIGINAL PURPOSE FOR THE ORIGINAL CLIENT. THIS DRAWING MAY NOT
BE REPRODUCED IN WHOLE OR IN PART, IN ANY MANNER OR STORED IN ANY FORM FOR
REPRODUCTION WITHOUT THE EXPRESS PERMISSION OF THE ARCHITECT. NO VALUE SHOULD BE
SCALED AND ALL VALUES SHOULD BE CHECKED AGAINST FIELD VALUES AND/OR .CHECKED WITH
THE ARCHITECT. IF ANY VALUES IS FOUND TO BE INCORRECT OR INVALID, THEN IT IS THE
RESPONSIBILITY OF THE USER TO INFORM THE ARCHITECT AND TO OBTAIN THE CORRECT VALUE
FROM THE ARCHITECT PRIOR TO ACTING.
25. PER W.S.E.C. SECTION 1416.3.2 ACCEPTANCE: FINAL CERTIFICATE OF OCCUPANCY SHALL NOT
BE ISSUED UNTIL THE BUILDING OFFICIAL DETERMINES THAT THE PRELIMINARY COMMISSIONING
REPORT REQUIRED BY SECTION 1416.2.6.2 HAS BEEN COMPLETED.
IF THIS DRAWING WAS CREATED AND/OR TRANSFERRED ON ELECTRONIC MEDIA TO ANY OTHER
PERSON OR BODY, THEN THE USER SHOULD BE AWARE THAT THE DRAWING MAY HAVE BEEN
ALTERED AFTER ISSUE BY THE ARCHITECT. THE ONLY ORIGINAL OF THIS DRAWING RESIDES IN THE
FILES OF THE ARCHITECT, AND SHALL TAKE PRECEDENT OVER ALL COPIES, PAPER OR ELECTRONIC.
THIS DRAWING MAY CONTAIN MATERIAL WHICH WAS PROVIDED FOR INFORMATION ONLY TO THE
ARCHITECT BY THE CLIENT OR CLIENTS CONSULTANTS. THE ARCHITECT ACCEPTS NO
RESPONSIBILITY FOR THE ACCURACY OR THE COMPLETENESS OF THIS MATERIAL. IF VALUES IN THE
DRAWING ARE FOUND TO BE CRITICAL TO THE SCOPE OF WORK, THEN THE USER IS ADVISED TO
REFER BACK TO THE ORIGINAL MATERIALS IN THE HANDS OF THE CLIENT.
FIRE CODE
FIRE ADDRESS: APPROVED ADDRESS SHALL BE PROVIDED FOR ALL BUILDINGS IN SUCH A POSITION AS
TO BE PLAINLY VISIBLE AND LEGIBLE FROM THE STREET OR ROAD FRONTING THE PROPERTY.
FIRE ADDRESS/TEMPORARY: TEMPORARY ADDRESSING IS REQUIRED DURING CONSTRUCTION SHALL BE
VISIBLE FROM THE STREET.
FIRE KNOX BOX: IF THE BUILDING OR SUITE HAS A FIRE PROTECTION SYSTEM, A KNOX BOX SHALL BE
INSTALLED IN AN APPROVED LOCATION AND ALL REQUIRED KEYS SHALL BE ON SITE FOR LOCK UP PRIOR
TO BUILDING FIRE FINAL.
FIRE OCCUPANT LOAD: OCCUPANT LOAD SHALL BE POSTED IN A CONSPICUOUS LOCATION AT OR AROUND
THE MAIN EXIT.
PORTABLE FIRE EXTINGUISHER: PORTABLE FIRE EXTINGUISHER WILL BE REQUIRED DURING CONSTRUCTION
AND INSTALLED FOR FINAL INSPECTION. CLASS 2A 1013C TYPE IS/ARE REQUIRED. PLEASE MOUNT THE
EXTINGUISHERS) IN A CONSPICUOUS LOCATION APPROVED BY THE FIRE DEPARTMENT AND LOCATE THE
EXTINGUISHER(S)
SO THAT THE TRAVEL
FROM ANY POINT IN SPACE DOES NOTX
E CEED 75
FEET TO AN EXTINGUISHER. (THE DISTANCE BETWEEN EXTINGUISHERS CAN BE 150 FEET).
FIRE SPRINKLER SYSTEM: STRUCTURE SHALL HAVE A FIRE SPRINKLER INSTALLED PER NFPA AND
EASTSIDE FIRE & RESCUE REQUIREMENTS. SUBMIT FOR A FIRE PERMIT.
ABBREVIATIONS E N E R G Y C 0 [0) E
AC ACCOUSTIC FIXT FIXTURE OD OUTSIDE DIAMETER EXISTING BUILDING- NO CHANGES TO BUILDING ENVELOPE.
ADD ADDENDUM FL FLASHING OFS OVERFLOW
ADD'N ADDITION FLR FLOOR SCUPPER
ABC AGGREGATE BASE F.D. FLOOR DRAIN OFD OVERFLOW DRAIN
COURSE FLUOR FLUORESCENT
AGG AGGREGATE FTG FOOTING PARA PARAPET
A/C AIR CONDITIONING FND FOUNDATION PTD PAINTED
AL ALUMINIUM FR FRAME PG PAGE
ALT ALTERNATE FHC FIRE HOSE CABINET PR PAIR
AB ANCHOR BOLT FV FIELD VERIFY PNL PANEL
ABV ABOVE PTN PARTITION
& AND GA GAUGE d PENNY
ARCH ARCHITECT GI GALVANIZED IRON PL PLATE
ASP ASPHALT GL GLASS PLBG PLUMBING
GD GRADE PLYWD PLYWOOD
BSMT BASEMENT GYP GYPSUM PT POINT
BM BEAM GWB GYPSUM WALL PSI POUNDS PER
BEL BELOW BOARD SQUARE INCH
B.M. BENCHMARK GRND GROUND PSF POUNDS PER
BLKG BLOCKING SQUARE FOOT
BD BOARD HR HANDRAIL PC PRECAST
BO BOTTOM OF HDN HARDENER PL PROPERTY LINE
BLDG BUILDING HDW HARDWARE
HDWD HARDWOOD R RADIUS
CABT CABINET HTR HEATER REG REGISTER
C.I.P. CAST IN PLACE HT HEIGHT REVD REQUIRED
C.B. CATCH BASIN HP HIGH POINT REV REVISION
CLG CEILING H. M. HOLLOW METAL RD ROOF DRAIN
CEM CEMENT HORIZ HORIZONTAL RFG ROOFING
CG CENTIGRAM HB HOSE BIB RM ROOM
CL CENTER LINE HW HOT WATER RGH ROUGH
CER CERAMIC RD ROUND
C.T. CERAMIC TILE IN INCH
CHAN. CHANNEL ID INSIDE DIAMETER SCR SCREW
CLR CLEAR INSUL INSULATION SECT SECTION
C.O. CLEAN OUT INT INTERIOR SEL SELECT
CLOS CLOSET INV INVERT SHT SHEET
COL COLUMN SDG SIDING
CONC CONCRETE JAN JANITOR SIM SIMILAR
CONN CONNECTION JT JOINT SLDG SLIDING S Y M 0 L S'
CONST CONSTRUCTION JST JOIST SM SMOOTH
_ CJ. CONTROL JOINT SPEC SPECIFICATION
CONSTRUCTION JOINT KP KICK PLATE SPL SPLASH y
CONT CONTINUOUS LAM LAMINATED STQD STANDARD D GRID LINE - -
CONTR CONTRACTOR
COR'G CORRUGATED LDG LANDING SS STAINLESS STEEL
CTR COUNTER LAV LAVATORY STRUC STRUCTURE
CTSK COUNTERSINK LG LENGTH SUSP SUSPENDED
CMU CONCRETE LOC LOCATION SWBD SWITCHBOARD DRAWING TITLE ---------- - ----- -- -
NAME
MASUNIT LT LWC LIGHT WEIGHT TC TOP OF CURB SCALE
CMS CORRUGATED
METAL SIDING CONCRETE TG TEMPERED GLASS
LVR LOUVER T. 0. TOP OFX SHEET #
D. A. DAMP PROOFING LOC LOCATION T. S. TUBE STEEL
DIAG DIAGONAL TSD TOP OF STEEL EXTERIOR X INTERIOR X X. X
DIAM DIAMETER MO MASONRY OPENING DECK ELEVATION KEY A4.X ELEVATION KEY X
DIM DIMENSION MATL MATERIAL TYP TYPICAL
DISP DISPENSER MFR MANUFACTURER
DWL DOWEL MAX MAXIMUM U.N.O. UNLESS NOTED
DN DOWN MCJ MAS CNTRL JNT OTHERWISE DETAIL X ENLARGED
D. S. DOWNSPOUT MECH MECHANICAL U.N.P. UNDER SEPARATE REFERENCEAX.X PLAN
DWG DRAWING MET METAL PERMIT X
MTL METAL X AX.X
EA EACH ML METAL LATH V VENT
EL ELECTRIC MID MIDWAY / MIDDLE VERT VERTICAL AXA
EDF ELECTRIC DRINKING MIN MINIMUM VEST VESTIBULE
FOUNTAIN MLDG MOULDING VCT VINYL COMPOSITION
ELEV ELEVATION MULL MULLION TILE
EQ EQUAL /WALL SECTION X BUILDING X X
EQUIP EQUIPMENT NG NATURAL GRADE WWM WELDED WIRE MESH AS.X SECTION A4.0 A4.0
EXH EXHAUST NOM NOMINAL WC WATER CLOSET
F EXP EXPANSION N.I.C. NOT IN CONTRACT WH WATER HEATER
EJ EXPANSION JOINT 0/ OVER WF WIDE FLANGE
EXIST EXISTING OBS OBSERVE W/ WITH DOOR NUMBER101 WINDOW TYPEHO
OC ON CENTER W/O WITHOUT
FT FEET OPG OPENING
FIN FINISH OA OVERALL WALL TYPE W1 FINISH TAG
N.T.S.
IBuiIding I'd entIh0 S
;Applicable Code IBC 2012 Edition
_ . __.._ - -- ,..... { - ,_ ........ .
'Site Area 3 3 ACRS
.........w......_w..... _
lZoning: C/LI
Mixed Use Class
Non Separated Uses
LOAD FACTOR
TOTAL OCC. LOAD
(Construction:
Type VB
:SPRINKLERED .
500 SF
_ _ _... ...... ............. .........
�Hel ht
g
. . . ... ......:....... _...
{
32 ft / h i hest otnt
{ g p }
_. . _.....
_. _..
... .. . ... L. _.... ;
Number of Stories
Two
11
STORAGE
Wind Exposure I Seismic Zone _
_ .............._.
NIA, Existing Structure
__.,...
E .,.....- ... _., L .. _.........
;Proposed Buiding;Uses/Exits Required
SCHEDULES & DETAILS
t
BUILDING B ROOF FRAMING PLAN
A2.3
Occ. Load
Exits Exits
CONCRETE DETAILS
Area
Factor
Occ. Load required Provided
Warehouse
3,506
500
7
Office
1,104
100
12
Total Ist floor
4;610
19 1 2
100
300
ITotal Mezzanine 1 1,065 1 1 11 I 1 1 j
TOTAL 5,675 30
49 s"q.� [ &z'3'
EXISTING BUILDING- PARKING REVIEWED AS PART OF SHELL AND CORE PERMIT.
INFORMATIONvnOJECT
N 1/4, N.E. 1/4, SEC. 23, T.23N, R.4E
KING COUNTY TAX ID #3365901605, 3365901630, 3365901570
oda::.
A TENANT IMPROVEMENT CONSISTING OF UNHEATED WAREHOUSE SPACE AND
OFFICE SPACE. THE OFFICE SPACE INCLUDES OPEN OFFICE AREA AND
RESTROOMS ON THE FIRST FLOOR, AND A MEZZANINE WITH AN OPEN OFFICE
AREA.
GROSS AREA
LOAD FACTOR
TOTAL OCC. LOAD
LOAD M/F
WAREHOUSE
3506.0
500 SF
7.0 / 2=
4
OFFICE
2058.0
100 SF
20.6 / 2=
11
STORAGE
111.0
300 SF
0.4 / 2=
1
TOTALI 16
PER TABLE 2902.1: WC (MALE & FEMALE):1 PER 25 LAVATORIES: 1 PER 40
EXISTING BUILDING- PARKING REVIEWED AS PART OF SHELL AND CORE PERMIT.
INFORMATIONvnOJECT
N 1/4, N.E. 1/4, SEC. 23, T.23N, R.4E
KING COUNTY TAX ID #3365901605, 3365901630, 3365901570
oda::.
A TENANT IMPROVEMENT CONSISTING OF UNHEATED WAREHOUSE SPACE AND
OFFICE SPACE. THE OFFICE SPACE INCLUDES OPEN OFFICE AREA AND
RESTROOMS ON THE FIRST FLOOR, AND A MEZZANINE WITH AN OPEN OFFICE
AREA.
WATER CLOSETS
LAVATORIES
STRUCTURAL
MALE
FEMALE
S1.1
REQUIRED:
1
1
2
PROVIDED:
1
1
2
EXISTING BUILDING- PARKING REVIEWED AS PART OF SHELL AND CORE PERMIT.
INFORMATIONvnOJECT
N 1/4, N.E. 1/4, SEC. 23, T.23N, R.4E
KING COUNTY TAX ID #3365901605, 3365901630, 3365901570
oda::.
A TENANT IMPROVEMENT CONSISTING OF UNHEATED WAREHOUSE SPACE AND
OFFICE SPACE. THE OFFICE SPACE INCLUDES OPEN OFFICE AREA AND
RESTROOMS ON THE FIRST FLOOR, AND A MEZZANINE WITH AN OPEN OFFICE
AREA.
FILE COPY
DEFEKKED SUBMITTi-A,
PD _i i1q subject to errnY; .9nd
JQa' ��a � i _ c r' • f ! t!c + l a:i� �:+� �t Ylont login
PLUMBING
trr� �s°If�� .., ...;;1;� 4�.�Ii,�ic?�1 ��_�,�,� �. ���er��'a��. I•'� �y�t
ELECTRICAL
of
app -r- r� aid Copy and co,! Ci.. � vi 2 >e ,c
0
{{4
BUILDING DIVISION
Elcctrical .,.,
Plumbing
Gas Piping
Ciiy of Tukwila
REVIEWED FOR
CODE COMPLIANCE
APPROVED
1MAR 2 2 2016
City of Tukwila
±UILDINC DIVISION
CITY OF TUKWILA
MAR 0 3 2016
"'ERMIT CENTER
ARCHITECTURAL
C4
STRUCTURAL
AO.1
COVER SHEET
S1.1
GENERAL STRUCTURAL NOTES
A1.0
SITE PLAN
S1.2
GENERAL STRUCTURAL NOTES
A2.0
FLOOR PLAN
S1.3
GENERAL STRUCTURAL NOTES
A2.1
MEZZANINE, ROOF & REFLECTED CEILING PLANS
S2.1
BUILDING B FOUNDATION PLAN
A2.2
SCHEDULES & DETAILS
S2.2
BUILDING B ROOF FRAMING PLAN
A2.3
SECTIONS & INTERIOR ELEVATIONS
S3.2
CONCRETE DETAILS
S5.1
TYPICAL METAL DECK DETAILS
6
UO
$5.7
CANOPY PLAN & DETAILS
S6.1
SHEAR WALL SCHEDULE & DETAILS
S6.2
STAIR PLANS & DETAILS
S6.3
FRAMING DETAILS
FILE COPY
DEFEKKED SUBMITTi-A,
PD _i i1q subject to errnY; .9nd
JQa' ��a � i _ c r' • f ! t!c + l a:i� �:+� �t Ylont login
PLUMBING
trr� �s°If�� .., ...;;1;� 4�.�Ii,�ic?�1 ��_�,�,� �. ���er��'a��. I•'� �y�t
ELECTRICAL
of
app -r- r� aid Copy and co,! Ci.. � vi 2 >e ,c
0
{{4
BUILDING DIVISION
Elcctrical .,.,
Plumbing
Gas Piping
Ciiy of Tukwila
REVIEWED FOR
CODE COMPLIANCE
APPROVED
1MAR 2 2 2016
City of Tukwila
±UILDINC DIVISION
CITY OF TUKWILA
MAR 0 3 2016
"'ERMIT CENTER
Job Number.
1005-0.037
J
C4
JANUARY
6, 2016
Principal In Charge:
WWAM FULLER
Project Manager.
VAHID KHASMU
ti C
ICU,
C4,.
c0
m,:;.
a:
F-
s
0
o
R M
t2
6
UO
H
W
a
Q
�
N
�
w
T
Q
CD
CM
G
Z
r
Job Number.
1005-0.037
Date:
C4
JANUARY
6, 2016
Principal In Charge:
WWAM FULLER
Project Manager.
VAHID KHASMU
ti C
ICU,
C4,.
c0
m,:;.
a:
s
0
o
R M
t2
6
UO
Job Number.
1005-0.037
Date:
JANUARY
6, 2016
Principal In Charge:
WWAM FULLER
Project Manager.
VAHID KHASMU
Drawn By.
AMY MCCURDY
[Sheet Title:OVER SHEET
Sheet Number.
AOml
U/MU H> "4111y''m t
200
� 2s -1W�y� FUUfR-SEA tS
ABt�091`rIE'C'3'9i
`
[
�
rA
`
TOP OF RIVER BANK
PARKING CALCULATIONS
REQUIRED: **
WAREHOUSE:
56,990 SF @ 1:2000 = 28.5 STALLS
RESERVED
00
PARKING
PrIncoal In Charge: WWAM FULLER
Project Manager VAHID KHASTOU
04
58,737 SF 62.5 TOTAL
Drawn By. AMY MCCURDY
TO CONCRETE WALKWAY OR
PAR IN G
NOTES: CitY of Tukwila
071C
Sheet Title:
4 — COMPACT STALLS (8' X 17' ANGLED)
LO
1. ACCESSIBLE PARK�180%E)ffWDIVIS ION
63 TOTAL (INCL. 4 HC STALIST_
I
COMPL
2. BUILDING MOUNT (A' OUNT
SITE PLAN
SITE AREA: 141,868 SF (3.3 ACRES)
—4'-0" CONC. SIDEWALK
ae
0 Cb
C6 qs
ENCLO
PARCEL LINE
HC
El
LINE
\ ^' DRIVE AISLEPARCELVAN
PED CROSSINGS
BLDG Q
SITE PLAR
/-- SIDEWALK
00 0 00 00 0000 00 0 000
00 000 0 000 00
00900000000000
000000000000000000000.0
00000000000000000000000
0004000 0000 000000000
000 0 000000000000000001
PROVIDE TRUNCATED DOMES �T
RAMP PER CHAR I ABOVE -"� ADA C"M
I-011
w
1
1 �^—n
./-r .
`~-- SETBACK TRUNCATED DOMES
PER PLAN G^ TO 8^ FROM CURB FACE
�������������� �� � ����
��m��� ��^��u�,�m� � � � .
r
NOT INCLUDING MECHANICAL ROOMS
AISLE
PATH OF TRAVEL FROMADA PARKING TO
BUILDING ENTRANCE
TRUNCATED DOMES AT
PED CROSSINGS TYP.
IT 100.7'
PROPERTY LINE
Li
00
vm
—| —
._ .'� ''--_—__
........ ....
CD
INTERURBAN AVENUE WORK THIS AREA
�A_ 2. FOR THIS PERMIT
TDI IMP A Trn
um°LJ ru` ru�ll
TOOLED JOINTS @J/4[
)E BAND
CURB & GUTTER
CONDITION WHERE
DCCUR3
TRAN|SITIONSFROM RAMP 0WALKS, GUTTERS, VECH|CLAR WAYS SHALL
BE FLUSH W/ NO ABRUPT CHANGES GREATER THAN 1/4^ |N HEIGHT
IF EITHER LANDING AREA IS LESS THAN 48' IN THE DIRECTION OF TRAVEL THE
FLARED SIDE SLOPES SHALL BE REDUCED TO 1 TO 12 RISE TO RUN
CURB RAMPS SHALL NOT BE POURED |NTERGALW/SIDEWALKS AND SHALL BE ISOLATED
BY 3/8" THICK EXPAN. JT MATERIAL ON ALL SIDES ABUTTING THE 0DEWALK,
ii� ADA RB/RAMP on TYP
1/4 �=�1`_O"
. "
o^Unu^u
/2\ COAT
J" WIDE PAINTED STRIPES,
PA|NT(2) COATS WHITE
BEADED REFLECTIVE PAINT
INTERNATIONAL SYMBOL OF
ACCESSIBILITY COMPLYING V0
umq|u1171—vno� qrrnom
'..~ ...'.' �...
CONCRETE CURB OR 4" WIDE STRIPING
STRIPING AS OCCURS
PER SITE PLAN
OF
STALL
NTS
3N WITH END OF
.// cro/mu, ---_
"."+�
8^ � G"
r6 5-0" 1 ACCES
--REVIEWED FOR
'7 -GODE COMPLIANCE
VAN ACCESSIBLE PARKIAPSRPOVED
SEE SITE PLAN FDR L.04�RN ,
2016
RESERVED
00
PARKING
PrIncoal In Charge: WWAM FULLER
Project Manager VAHID KHASTOU
04
RES VED
Drawn By. AMY MCCURDY
TO CONCRETE WALKWAY OR
PAR IN G
NOTES: CitY of Tukwila
071C
Sheet Title:
1000
9
LO
1. ACCESSIBLE PARK�180%E)ffWDIVIS ION
F0 tM"
kmo
I
COMPL
2. BUILDING MOUNT (A' OUNT
SITE PLAN
ro
cn
LINE OF PAVING
Ll
Im
CS
CIO
IL
CM
8^ � G"
r6 5-0" 1 ACCES
--REVIEWED FOR
'7 -GODE COMPLIANCE
VAN ACCESSIBLE PARKIAPSRPOVED
SEE SITE PLAN FDR L.04�RN ,
2016
RESERVED
00
PARKING
PrIncoal In Charge: WWAM FULLER
Project Manager VAHID KHASTOU
04
RES VED
Drawn By. AMY MCCURDY
TO CONCRETE WALKWAY OR
PAR IN G
NOTES: CitY of Tukwila
071C
Sheet Title:
1000
9
LO
1. ACCESSIBLE PARK�180%E)ffWDIVIS ION
F0 tM"
kmo
I
COMPL
2. BUILDING MOUNT (A' OUNT
SITE PLAN
ro
cn
LINE OF PAVING
Ll
CS
8^ � G"
r6 5-0" 1 ACCES
--REVIEWED FOR
'7 -GODE COMPLIANCE
VAN ACCESSIBLE PARKIAPSRPOVED
SEE SITE PLAN FDR L.04�RN ,
2016
RESERVED
PARKING
PrIncoal In Charge: WWAM FULLER
Project Manager VAHID KHASTOU
"SMT" TWIST LOCK BASE. BOLT
RES VED
Drawn By. AMY MCCURDY
TO CONCRETE WALKWAY OR
PAR IN G
NOTES: CitY of Tukwila
Sheet Title:
�o
LO
1. ACCESSIBLE PARK�180%E)ffWDIVIS ION
| `—|
I
COMPL
2. BUILDING MOUNT (A' OUNT
SITE PLAN
SIGN ON WALL dlAgi, MILA
ACCESSIBLE
PARKING SIGN
"SAFE—HIT" FLEXIBLE POST W/
r6 5-0" 1 ACCES
--REVIEWED FOR
'7 -GODE COMPLIANCE
VAN ACCESSIBLE PARKIAPSRPOVED
SEE SITE PLAN FDR L.04�RN ,
2016
�
�
Date.
JANUARY 6, 2016
PrIncoal In Charge: WWAM FULLER
Project Manager VAHID KHASTOU
"SMT" TWIST LOCK BASE. BOLT
Drawn By. AMY MCCURDY
TO CONCRETE WALKWAY OR
NOTES: CitY of Tukwila
Sheet Title:
ASPHALT SURFACE.
LO
1. ACCESSIBLE PARK�180%E)ffWDIVIS ION
I
COMPL
2. BUILDING MOUNT (A' OUNT
SITE PLAN
SIGN ON WALL dlAgi, MILA
LINE OF PAVING
MAR 0 3 7016
ACCESSIBLE
PARKING SIGN
"SAFE—HIT" FLEXIBLE POST W/
r6 5-0" 1 ACCES
--REVIEWED FOR
'7 -GODE COMPLIANCE
VAN ACCESSIBLE PARKIAPSRPOVED
SEE SITE PLAN FDR L.04�RN ,
2016
Job Number
1005-0.037
Date.
JANUARY 6, 2016
PrIncoal In Charge: WWAM FULLER
Project Manager VAHID KHASTOU
"SMT" TWIST LOCK BASE. BOLT
Drawn By. AMY MCCURDY
TO CONCRETE WALKWAY OR
NOTES: CitY of Tukwila
Sheet Title:
ASPHALT SURFACE.
LO
1. ACCESSIBLE PARK�180%E)ffWDIVIS ION
I
COMPL
2. BUILDING MOUNT (A' OUNT
SITE PLAN
SIGN ON WALL dlAgi, MILA
LINE OF PAVING
MAR 0 3 7016
a 20w
AARCHITECTS
(2.1) ---
RTU -1
Total capacity 59.8 MBH
Sensible capacity 45.3 MBH
Refrigerant type R-41 OA
Seasonal Efficiency (at ARI) 13.00 SEER
Efficiency (at ARI) 10.80 EER
Ambient DB temp. 95.0 °F
Entering DB temp. 80.0 °F
Entering WB temp. 67.0 °F
Leaving DB temp. 59.0 °F
Leaving WB temp. 57.6 °F
Power input (w/o blower) 4.54 kW
Sound power 82 dB(A)
Gas Heating Performance
Entering DB temp. 60 °F
Heating output capacity (Max) 100 MBH
Supply air 2000 CFM
Heating input capacity (Max) 125 MBH
Leaving DB temp. 106.3 °F
Air temp. rise 46.3 °F
SSE 80.6 %
Stages 1
Supply Air Blower Performance
Supply air 2000 CFM
Ext. static pressure 0.6 IWG
Addl. Unit Losses (Options/Accessories) 0.15 IWG
Blower speed 1103 RPM
Duct location Bottom
Motor rating 1.00 HP
Actual required BHP 1.02 HP
Power input 0.95 kW
Elevation 0 ft.
Drive type DIRECT
Speed tap 5
Electrical Data
Power supply 230-3-60
Unit min circuit ampacity 27.5 Amps
Unit max over -current protection 35 Amps
Dimensions & Weight
Hgt 33 in. Len 83 in. Wth 45 in.
Weight with factory installed options 644 lbs.
MECHANICAL SCHEDULE
TAG MODEL CFM Gas input Economizer HP VOLTAGE
AMPS
RTU -1 York ZF060N10A2AAA4 2000 120,000 100% 1 208/3 35
amp
EF -1 Nutone 100 115v 100CFM
i
la"' T Fm L • ! R R _. w. M10 ;"6m "I" E D C E I L I NU10" P L A N
1 /4"=1'-0"
2
1
05
C5
C5
4)- - -- --
161
05
C5
-- 240 CFM�typof4
8" round
C5
10'-3" A.F.F
A.C.T.
C5
C5
B
C
(C
M(b1%002)3
14" supply and return
down to 1 st floor
141
C5
■
Supply and return
up to RTU -1
C5
C5 II ! II C5
MEZZANINE
REFLECTED
E I
PLAN.
Num
FOR
J
CODE COM " INCE
Job Number:
E�
ao
co
C6
0
2 2 2016.
Date:
N
JANUARY 6, 2016
CD
",4d,l
Project Manager. VAHID KHASMIJ
CD
00
Drawn By. AMY MCCURDY
MIA
uhta��
4
s
coN
CB
a
u
N
H
Cn
W
IL
Q
�
J
�
1—
�
W
t—
Q
in
CM
CO
1
Z
r
FOR
CODE COM " INCE
Job Number:
E�
ao
co
C6
0
2 2 2016.
Date:
N
JANUARY 6, 2016
CD
",4d,l
Project Manager. VAHID KHASMIJ
CD
00
Drawn By. AMY MCCURDY
MIA
uhta��
4
s
coN
CB
a
u
FOR
CODE COM " INCE
Job Number:
E�
1005-0.037
2 2 2016.
Date:
JANUARY 6, 2016
Principal in Charge: WWAM FULLER
'/
City Olg Tukwila
Project Manager. VAHID KHASMIJ
BUILDING DIVISION
Drawn By. AMY MCCURDY
uhta��
u
FOR
CODE COM " INCE
Job Number:
E�
1005-0.037
2 2 2016.
Date:
JANUARY 6, 2016
Principal in Charge: WWAM FULLER
'/
City Olg Tukwila
Project Manager. VAHID KHASMIJ
BUILDING DIVISION
Drawn By. AMY MCCURDY
_--R-.E-G ELV_E D "
CITY OF TUKWILA
MAR 0 3 2016
PERMIT CENTER
Williams Mechanical
Bill A
425 754 8759
1
f
m
3
a
U
24'-8"
CANOPY FRAMING j
PER PARTIAL PLAN 1
OF 20/55.1, TYP.
8/55.$
pu ,
/5 ^
2
8
I'I/55.4
[H
do 0
r--- f
0
N
do
N
do
.4
5TRUT
C D
15'-0" E
21'-4 26'-4"
Existing 21b Gas
meter
__---_ --_ 1"Gas line to RTU -1
I
STRUT�o� �,o T TRUT
■mma mono.■■.. mummm.. .............. .am a 1 0.do
�- do
■44
Existing 1" gas line
2lbs
REINF. DECK
OPENING5
PER 3/55.1
do o do t
■ Existing 75,000 BTU
d� d0 d0 Gas Unit Heater
N
■ N NOTE I N
■ do do 1
T.O. 5TEEL °Q9
RTU -1 on roof
STi�UT
100,000 BTU STRUT STRUT I
• 15/55.4 10/55.4/55.41
■
NI2 26 2bC70b.2K 28G4N8.2K
STRur (aW
- - 20/55.4 1 6/55.4
MM: ■ in I I 5TRUT^ 5TRUT
NOTE 7 - J =
- o
5x5x-46 _ '
ZZ
T.O.
0
-T N1422 [26'-b3/6"] - A142242645/61
20J55.2 [L 20/5r-.2 [L]
/55.4 [H] IS/55.4 12/55 [H] [H] 11/55.4
� 5x5x5�f6 CONNECT TO
.4 PER 3/55.1 CONNECT
TO COL. PER 14/55.2 MEZZANINE N
(W5 ( ONDITION) PLATED PER
F
�HANIGAL UNIT
LAN NOTE I
o I
do do
r I
N
3/55.3
' T 5TRUT
T.0.5TEEL
EL.=2b'-1V2" o
I. ROOF DECKING 5HALL BE IV2" DEEP x 226A, U.O.N. 5EE 5/55.1 FOR PROPERTIES AND ATTACHMENT REQUIREMENTS.
2. J015T MANUFACTURER 5HALL DESIGN J015T5 FOR LOA05 INDICATED A5 WELL A5 MECHANICAL EQUIPMENT. J015T5
5HALL BE ADDED FOR 5PEGIAL LOAD5 AND OPENINGS A5 REQUIRED.
3. LEDGER ANCLE5 OR EMBEDDED PLATES ARE REQUIRED AT ALL INTER5EGTION5 OF METAL DECKING AND CONCRETE OR
MA50NRY WALL5. 5EE DETAIL5.
4. 5EE METAL DECKING NOTES FOR SPECIAL CONNECTION REQUIREMENTS AT 5TRUT5. 5EE DETAIL 2/55.4 FOR
FILLER 4 REQUIRED AT J015T DENOTED 5TRUT
5. STEEL J015T5 5HALL BE 5PAGED EQUALLY A5 5HOWN, U.O.N.
6. J015T MANUFACTURER 5HALL DE516N J015T5 FOR THE UNIFORM LINE LOADS INDICATED ON PLAN (TOTAL LOAD, LIVE
LOAD) WHIGH INCLUDE AN ALLOWANCE FOR THE WEIGHT OF J015T5. IN ADDITION, DE516N FOR 5UPERIMP05ED
CONCENTRATED LOAD5 INDICATED ON THE DRAW0,65 AND AND NET WIND UPLIFT FORGE OF 7 P517. FOR J015T
DENOTED 'STRUT' DE516N TOP CHORD TO RE515T FACTORED EARTHQUAKES LOAD 5HOWN.
1. MECHANICAL UNIT MAX. WEIGHT 2,000 Ibs. SUPPORT EA. 51DE OF UNIT WITH 4 5x5x3/8 CONNECT 4 TO
ROOF FRAMING 4 EA. OTHER PER 3/55.1. SUPPORT DUCT OPENING5 IN THE ROOF PER 3/55.1.
b. THE GENERAL CONTRACTOR 5HALL REINFORCE ALL OPENING5 AT ROOF DEGK5 PER GENERAL 5TRUGTURAL NOTE Ib.
ALL OPENING5 MAY NOT BE 5HOWN ON THE 5TRUGTURAL DRAWIN65. 5EE ARCHITECTURAL, MECHANICAL AND
ELECTRICAL PRAAING5 FOR ADDITIONAL OPENIN65 NOT 5HOWN. CONTRACTOR 5HALL COORDINATE OPENING
DIMEN51ON5 AMONGST ALL TRADES.
t
[x' -x"]
TOP OF STEEL BEAM ELEVATION
TA. STL.
TOP OF STEEL EQUAL5
EL.=x'-x"
BOTTOM OF METAL DECK
.4 STRUT
4 5x5x6 - 5PLICE PER 14/55.1
[H], [L]
RELATIVE PLACEMENT OF FRAMING
MEMBER OR DETAIL GUT.
3YX ^iXGa41r^Y 3tM`a i aka
[H] HIGH, [L] LOW
TL=xk
TOTAL LOAD (KIP5)
LL=xk
LIVE LOAD (KIP5)
C=X11AMOUNT OF CAMBER REQUIRED
AT BEAM M105PAN
5EE GENERAL STRUCTURAL NOTE 14.
77/-/7/-/-= MA50NRY SHEAR WALL
STRUT DRAG STRUT OR CHORD COMPONENT OF
THE 5EI5MIC FORGE RE515TIN6 5Y5TEM
DIAPHRAGM DIAPHRAGM AT THI5 LEVEL GON515T5 OF THE
ROOF DECK PER PLAN NOTE I.
RTU -1 with economizer
Total capacity 59.8 MBH
Sensible capacity 45.3 MBH
Refrigerant type R -410A
Seasonal Efficiency (at ARI) 13.00 SEER
Efficiency (at ARI) 10.80 EER
Ambient DB temp. 95.0 °F
Entering DB temp. 80.0 °F
Entering WB temp. 67.0 °F
Leaving DB temp. 59.0 °F
Leaving WB temp. 57.6 °F
Power input (w/o blower) 4.54 kW
Sound power 82 dB(A)
Gas Heating Performance
Entering DB temp. 60 °F
Heating output capacity (Max) 100 MBH
Supply air 2000 CFM
Heating input capacity (Max) 125 MBH
Leaving DB temp. 106.3 °F
Air temp. rise 46.3 °F
SSE 80.6 %
Stages 1
Supply Air Blower Performance
Supply air 2000 CFM
Ext. static pressure 0.6 IWG
Addl. Unit Losses (Options/Accessories) 0.15 IWG
Blower speed 1103 RPM
Duct location Bottom
Motor rating 1.00 HP
Actual required BHP 1.02 HP
Power input 0.95 kW
Elevation 0 ft.
Drive type DIRECT
Speed tap 5
Electrical Data
Power supply 230-3-60
Unit min circuit ampacity 27.5 Amps
Unit max over -current protection 35 Amps
Dimensions & Weight
Hgt 33 in. Len 83 in. Wth 45 in.
Weight with factory installed options 644 lbs.
Gas sizing per International Fuel Code
Existing unit heater 75,000 BTU + RTU -1 125,000 BTU = 200,00.0 BTU Total
Existing 2 PSI meter
1" Line Capacity at 125ft table 1,530,000 BTU
Capacity still available 1,205,000 BTU
NOTE: American Meter regulator will be installed on roof reducing Gas pressure
to standard inches water column with vent to atmosphere
I (Mechanical HVAC Gas and Structural Plan
REVIEWED FOR
CODE COMPLIANCE
APPROVED
MAR 2 2 2016
Cit}! of Tulmila
BUIEAPPffi �;I( rq
1;1 -'Tl:1�
-4 PKKKK FL
MAR 0 3 2016
PERMIT CENTER
Job Number.
S101203-02
Date:
JANUARY 27, 2016
Principal in Charge: JEC
Project Manager:
Drawn By. MRM
Sheet Title:
BUILDING B
ROOF FRAMING
PLAN
0
® 2010
FULLER -SEARS
I ARCHITECT$
H
3YX ^iXGa41r^Y 3tM`a i aka
'�Y3Y�a�`;�'v7@;
szz kn�r �ti
eszvt+i�4lS�>k2s
Y� ...........
&�'tz�73�rtr3}T�awx%
iY�U7;� -
DO I SECOND AVENUE - SUITE 900 P. 206/343-0460
SEATTUE.WA 98104 R 2061343-5691
F
m
H
W
�
a
,Q
N
w
I---
V-
r
<
�
o
0
z
Job Number.
S101203-02
Date:
JANUARY 27, 2016
Principal in Charge: JEC
Project Manager:
Drawn By. MRM
Sheet Title:
BUILDING B
ROOF FRAMING
PLAN
0
® 2010
FULLER -SEARS
I ARCHITECT$
3YX ^iXGa41r^Y 3tM`a i aka
'�Y3Y�a�`;�'v7@;
szz kn�r �ti
eszvt+i�4lS�>k2s
Y� ...........
&�'tz�73�rtr3}T�awx%
iY�U7;� -
DO I SECOND AVENUE - SUITE 900 P. 206/343-0460
SEATTUE.WA 98104 R 2061343-5691
Job Number.
S101203-02
Date:
JANUARY 27, 2016
Principal in Charge: JEC
Project Manager:
Drawn By. MRM
Sheet Title:
BUILDING B
ROOF FRAMING
PLAN
0
® 2010
FULLER -SEARS
I ARCHITECT$