MECHANICAL PERMIT
Parcel No:
9202470070
Permit Number: M16-0035
Address:
215 ANDOVER PARK W
Issue Date: 3/7/2016
WA Cities Electrical Code:
2014
Permit Expires On: 9/3/2016
Project Name:
FIRESTONE
2014
Owner:
2012
WA State Energy Code:
Name:
JC PENNY CORP INC
2012
Address:
PO BOX 10001 TAX DEPT M/S 1217,
Permit Center Authorized Signature:
DALLAS, WA, 75301
Date:
Contact Person:
Name:
MARKTEMPLETON
Phone: (253) 797-5008
Address:
1514 CENTRAL AVE 5, KENT, WA,
98032
Contractor:
Name:
COMPLETE RESTAURANT REPAIR
Phone: (253) 852-0624
Address:
PO BOX 203, KENT, WA, 98035
License No:
COMPLRR893D9
Expiration Date: 3/29/2017
Lender:
Name:
Address:
DESCRIPTION OF WORK:
REMOVE TWO 7.5 TON AIR HANDLERS AND 7.5 TON CONDENSERS AND INSTALL TWO NEW TRANE 7.5 TON
UNITS.
Valuation of Work: $0.00
Fees Collected: $367.45
Type of Work:
REPLACEMENT
Electrical Service Provided by: PUGET SOUND ENERGY
Fuel type: ELECT
Water District: TUKWILA
Sewer District: TUKWILA SEWER SERVICE
Current Codes adopted by the City of Tukwila:
International Building Code Edition:
2012
National Electrical Code:
2014
International Residential Code Edition:
2012
WA Cities Electrical Code:
2014
International Mechanical Code Edition:
2012
WAC 296-4613:
2014
Uniform Plumbing Code Edition:
2012
WA State Energy Code:
2012
International Fuel Gas Code:
2012
Permit Center Authorized Signature:
(i(/
Date:
I hearby certify that I have read and examined this permit and know the same to be true and correct. All
provisions of law and ordinances governing this work will be complied with, whether specified herein or not.
The granting of this permit does not presume to give authority to violate or cancel the provisions of any other
state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this
development permit and agree to the conditions attached to this permit.
Signature: Date
Print Name: Ar /C-/
This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if
the work is suspended or abandoned for a period of 180 days from the last inspection.
PERMIT CONDITIONS:
1: ***MECHANICAL PERMIT CONDITIONS***
2: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila
Permit Center (206/431-3670).
3: All permits, inspection record card and approved construction documents shall be kept at the site of work
and shall be open to inspection by the Building Inspector until final inspection approval is granted.
4: Manufacturers installation instructions shall be available on the job site at the time of inspection.
5: Except for direct -vent appliances that obtain all combustion air directly from the outdoors; fuel -fired
appliances shall not be located in, or obtain combustion air from, any of the following rooms or spaces:
Sleeping rooms, bathrooms, toilet rooms, storage closets, surgical rooms.
6: Equipment and appliances having an ignition source and located in hazardous locations and public garages,
PRIVATE GARAGES, repair garages, automotive motor -fuel dispensing facilities and parking garages shall be
elevated such that the source of ignition is not less than 18 inches above the floor surface on which the
equipment or appliance rests.
7: Type 1 Hoods, the required grease duct leakage test and Ilight test shall be performed by a special
inspection and testing agency in accordance with I.M.C. Chapter 5.
PERMIT INSPECTIONS REQUIRED
Permit Inspection Line: (206) 438-9350
1800 MECHANICAL FINAL
0701 ROUGH -IN MECHANICAL
CITY OF TUKWILA
Community Development Department
Permit Center
• 6300 Southcenter Blvd., Suite 100
Tukwila, WA 98188
http://www.Tukwi]aWA.izov
SITE LOCATION
Mechanical Permit No. 1D —
Project No.
Date Application Accepted:
Date Application Expires:
use
MECHANICAL PERMIT APPLICATION
Applications and plans must be complete in order to be accepted for plan review.
Applications will not be accepted through the mail or by fax.
**please print**
King Co Assessor's Tax No.: 920247007007
Site Address: 215 Andover Park W Tukwila WA 98188 Suite Number: Floor:
Tenant Name: Firestone New Tenant:
❑ .....Yes ®..No
PROPERTY OWNER
Name: JC Penny Corp Inc
Address: PO Box 10001
City: Dallas State: TX Zip: 75301
CONTACT PERSON — person receiving all project
communication
Name: Mark Templeton
Address: 1514 Central Ave S
City: Kent State: WA Zip: 98032
Phone: (253) 797-5008 Fax:
Email: mark@completerestaurantrepair.com
Valuation of project (contractor's bid price): $ 19,500
Describe the scope of work in detail:
MECHANICAL CONTRACTOR INFORMATION
Company Name: CRR
Address: PO Box 203
City: Kent State: WA Zip: 98035
Phone: (800) 509-4105 Fax:
Contr Reg No.: COMPLRR893D9 Exp Date: 03/29/2017
Tukwila Business License No.:
Remove two 7.5 ton air handlers and 7.5 ton condensers and install two new Trane 7.5 ton units.
Use: Residential:
New
.......... ❑
Replacement ........
❑
Commercial:
New
.......i@w
Replacement ........
m
Fuel Type: Electric.....
0
Gas .......
❑ Other:_
H:\Applications\Porm-Applications On Line\2016 ApplicationsWechanical Permit Application Revised 14-16.docx
Revised: January 2016 Page 1 of 2
bh
Indicate type of mechanical work being installed and the quantity below:
Unit Type
Qty
Furnace <100k btu
2
Furnace >100k btu
2
Floor furnace
1
Suspended/wall/floor
mounted heater
57 dB(A)
Appliance vent
Commercial
Repair or addition to
heat/refrig/cooling
system
47 dB(A)
Air handling unit
<10,000 cfrn
65 dB(A)
Unit Type
Qty
Air handling unit
>I0,000 cfm
2
Evaporator cooler
2
Ventilation fan
connected to single duct
1
Ventilation system
57 dB(A)
Hood and duct
Commercial
Incinerator — domestic
47 dB(A)
Incinerator —
comm/industrial
65 dB(A)
Unit Type
Qty
Fire damper
Residential, Nighttime
Diffuser
2
Thermostat
1
Wood/gas stove
57 dB(A)
Emergency enerator
Commercial
Other mechanical
equipment
47 dB(A)
60 dB(A)
65 dB(A)
Boiler/Compressor
Qty
0-3 hp/100,000 btu
Residential, Nighttime
3-15 h /500,000 btu
2
15-30 hp/1,000,000 btu
55 dB(A)
30-50 hp/1,750,000 btu
57 dB(A)
50+ hp/1,750,000 btu
Commercial
57 dB(A)
47 dB(A)
60 dB(A)
65 dB(A)
Noise:
Mechanical units need to be in compliance with the Tukwila Noise Code. Maximum permissible sound levels are based on from where the sound is
created and where the sound is heard. Additionally, if sound can be heard from within a house at night in a residential zone it may not be allowed.
For more details, see TMC 8.22
District of Sound
Producing Source
District of Receiving Property
Residential, Daytime*
Residential, Nighttime
Commercial
Industrial
Residential
55 dB(A)
45 dB(A)
57 dB(A)
60 dB(A)
Commercial
57 dB(A)
47 dB(A)
60 dB(A)
65 dB(A)
Industrial
60 dB(A)
50 dB(A)
65 dB(A)
70 dB(A)
*Daytime means 7AM-1OPM, Monday through Friday and 8AM-IOPM, Saturday, Sunday and State -recognized holidays.
A few sounds are exempt from the noise code, including:
Warning devices;
Construction and property maintenance during the daytime hours (lam-IOpm);
Testing of backup generators during the day.
PERMIT APPLICATION NOTES -
Value of construction — in all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject
to possible revision by the permit center to comply with current fee schedules.
Expiration of plan review — applications for which no permit is issued within 180 days following the date of application shall expire by limitation.
The building official may grant one extension of time for additional periods not to exceed 90 days each. The extension shall be requested in writing
and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition).
I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER
PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT
BUILDING OWNER
Print Name:
Mailing Address:
Date: / S�
/Day Telephone: 2e,0C - r 3 / 07/j
"JT
City
D�
State Zip
H:4lppliwtions\Forms-Applications On Line\2016 Applicatiou\Mechanical Permit Application Revised 14-16.docx
Revised: January 2016 Page 2 of 2
bh
DESCRIPTIONS
ACCOUNT QUANTITY
PAID
PermitTRAK
$367.45
M16-0035 Address: 215 ANDOVER PARK W
Apn: 9202470070
$367.45
MECHANICAL
$349.95
PERMIT ISSUANCE BASE FEE
R000.322.100.00.00 0.00
$32.50
PERMIT FEE
R000.322.100.00.00 0.00
$317.45
TECHNOLOGY FEE
$17.50
TECHNOLOGY FEE
TOTAL FEES PAID BY RECEIPT: R7844
R000.322.900.04.00 0.00
$17.50
$367.45
Date Paid: Monday, March 07, 2016
Paid By: ADVANCED HOME
Pay Method: CREDIT CARD 07032G
Printed: Monday, March 07, 2016 12:52 PM 1 of 1
I?WSYS7EMS
Mechanical Specifications - Split System Air Conditioning Units (Large)
Item: Al Qty: 2
General - TWA
Weatherproofed Steel Mounting/Lifting Rails
Hermetic Scroll Compressors
Plate Fin Condenser Coils
Fans and Motors
Standard Operating Range 50-125F (Min. 0°F with Low Ambient Accy)
Nitrogen Holding Charge
Certified and Rated in Accordance with AHRI and DOE Standards
Certified to UL 1995
Casing - TWA
Zinc Coated, Heavy Gauge, Galvanized Steel
Weather Resistant Baked Enamel Finish
Meets 672 hr Salt Spray Test
Removable Single Side Maintenance Access Panels
Lifting Handles in Maintenance Access Panels
Unit Base Provisions for Forklift and/or Crane Lifting
Refrigeration System - TWA
Single Compressor (TWA073D, TWA090D, TWA120D)
Single Refrigeration Circuit with Integral Subcooling Circuit.
Single Direct Drive Hermetic Scroll Compressor with Centrifugal Oil Pump Providing Lubrication To Moving Parts
Suction Gas -Cooled Motor w/ t 10% Voltage Utilization Range of Unit Nameplate Voltage
Reversing Valve
Crankcase Heater
Internal Temperature and Current Sensitive Motor Overloads
No Compressor Suction and/or Discharge Valves (Reduced Vibration/Sound)
Factory Installed Liquid Line Filter Drier
Phase Loss/Reverse Rotation Monitor
Liquid Line Service Valve (with gauge port)
Suction Line Service Valve (with gauge port)
External High Pressure Cutout Device
External Low Pressure Cutout Device
Evaporator Defrost Control
Loss of Charge Protection (Discharge Line Thermostat)
Condenser Coil - TWA
3/8" Internally Enhanced Copper Tube Mechanically Bonded to Lanced Aluminum Plate Fins
Factory Pressure and Leak Tested to 660 psig.
Condenser Fan - TWA
26" or 28" Propeller Fan(s)
Direct Drive
Statically and Dynamically Balanced
Condenser Motor(s) - TWA
Permanently Lubricated Totally Enclosed or Open Construction
Built -In Current and Thermal Overloads
Ball or Sleeve Bearing Type
Controls - TWA
Centralized MicroProcessor
Indoor and Outdoor Temperature Sensors Drive Algorithms Making Decisions for All Heating, Cooling, and Ventilation
Integrated Anti -Short Cycle Timer
Integrated Time Delay Between Compressors
Completely Internally Wired
Numbered and Colored Wires
Contactor Pressure Lugs or Terminal Block
Unit External Mounting Location for Disconnect Device
Single Point Power Entry
FLD = Furnished by Trane U.S. Inc. dba Trane / Equipment Proposal Page 4 of 18
Installed by Others
General - TWE
Completely Factory Assembled
Convertible for Horizontal or Vertical Configuration
Convertible for Cooling Only or Heat Pump Application
Convertible for Left or Right External Connections (Refrigerant and/or Electrical)
Convertible for Front or Bottom Air Return
Nitrogen Holding Charge
Certified and Rated in Accordance with AHRI and DOE Standards
Certified to UL 1995 for Indoor Blower Coil Units
Casing - TWE
Zinc Coated, Heavy Gauge, Galvanized Steel
Weather Resistant Baked Enamel Finish
Access Panels with Captive Screws
Completely Insulated with Foil Faced, Cleanable, Fire Retardant, Permanent, Odorless Glass Fiber Material
Captured or Sealed Insulation Edges
Electrical Connection Bushings or Plugs
Refrigerant Connection Bushings or Plugs
Withstand Elevated Internal Static Pressure
Refrigeration System - TWE
Single or Dual Circuit
Distributor(s)
Thermal Expansion Valves (TXVs)
Evaporator Coil - TWE
3/8" Internally Enhanced Copper Tube Mechanically Bonded to Lanced Aluminum Plate Fins
Factory Pressure and Leak Tested to 449 psig.
Draw -Through Airflow
Dual Circuits Are Interlaced/Intertwined
Double Sloped, Removable, Cleanable, Composite Drain Pan
Four Drain Pan Positions
Indoor Fan - TWE
Double Inlet, Double Width, Forward Curved, Centrifugal Type Fan
Dual Fans On 10.4-20.912.5-25 Ton Air Handlers
Adjustable Belt Drive
Permanently Lubricated Bearings
Indoor Motor - TWE
Adjustable Motor Sheaves
Fixed Motors Sheaves (SZVAV and 2 -Speed VFD)
Thermal Overload Protection
Permanently Lubricated Bearings
Meet Energy Policy of 1992 (EPACT)
Optional Over Sized Motors for High Static Applications
Controls - TWE
Completely Internally Wired
Numbered and Colored Wires
Magnetic Indoor Fan Contactor
Low Voltage Terminal Strip
Single Point Power Entry
Evaporator Defrost Control
Filters - TWE
Access From Side Coil Panels
Filters Slide on Rack
One Inch (1"), Throw -Away Filters on 4.6-8.335-10 Ton Units
Filter Rack Convertible to Two Inch (2") Capability on 5-10 Ton Units
Two Inch (2"), Throw -Away Filters on 10.4-20.912.5-25 Ton Units
FLD = Furnished by Trane U.S. Inc. dba Trane / Equipment Proposal Page 5 of 18
Installed by Others
Electric Heaters - TWE
Heavy Duty Nickel Chromium Elements
cETL Approved
Installs Directly On Fan Discharge
One or Two Stage Control (Dependent Upon Capacity)
Single Point Power Entry
Terminal Strip Connections
460V Heaters
Internally Wye Connected
Automatic Line Break High Limit Controls
230V Heaters
Internally Delta Connected
Automatic Reset of High Limit Controls Through Pilot Duty with Secondary Backup Fuse Links
FLD = Furnished by Trane U.S. Inc. dba Trane / Equipment Proposal Page 6 of 18
Installed by Others
Unit Dimensions - Split System Air Conditioning Units (Large)
Item: Al Qty: 2
ELECTRICAL DATA CONDENSER
'ELECTRICAL DATA
COMPRESSOR MOTOR
CONDENSER FAN MOTOR
Model: TWA090D4
No.: '1
No.: 1
Unit Operating Voltage: 414-506
Volts: 460
Volts: 460
Minimum Circuit Ampacity: 17.9
Phase: 3
Phase: 1
Maximun Fuse Size: 25.0
Amp-RLA: 13.0
Amp -FLA: 1.6
Maximun Circuit Breaker: 25.0
Amp -LRA: 100.0
Amp -LRA: 3.8
GENERAL DATA CONDENSER
COOLING PERFORMANCE (1)(2)(3)(4)(5)
COMPRESSOR
Matched Air Handler:
.93,000
Number.
.1
Condensing Unit Only:
86,000
ARI Net Cooling Capacity:
90,000
Motors/HP (each):
6.9
11 0
Motor RPM:
3500
Matched Air Handler (EER):
12.2
No. Compressor/ Tons:
1/6.9
Condensing Unit Only (EER):
N/A
System Integrated Part Load Value (IPLV): N/A
Condensing Unit Only (I PLV):
8.18
SYSTEM DATA 1�)
System KW
7.05
'1
Condensing Unit KW:
9 No. Refrigerant Circuits:
Suction Line (in.) OD:
1 3/8"
Liquid Line (in.) OD:
5/8"
System IEER:
11.7
OUTDOOR COIL
OUTDOOR FAN
Tube Size (in.) OD
•3/8"
No. Used/Diameter (in.):
'1 / 26"
Face Area (sq. ft.)
19 1/4"
Drive Type/No. Speeds:
DIRECT / 1
Rows/FPI
2/18
CFM:
6,530
No. Motors/HP:
1/0.5
Motor RPM:
1,100
REFRIGERANT CHARGE (Fld Supplied) (n(e)
TYPE: R410A
(Circuits #1): 19.6 Ib
(Circuits #2): N/A
NOTES:
1. Cooling performance is rated at 95 F ambient, 80 F entering dry bulb, 67 F entering wet bulb.
Gross capacity does not include the effect of fan motor heat. AHRI capacity is net and includes
the effect of fan motor heat. Ratings shown are tested and certified in accordance with AHRI
2. Standard 340/360 or 365 certification program.
3. Condensing Unit Only Gross Cooling Capacity rate at 45 F saturated suction temperature and
at 95 F ambient.
4. ARI Net Cooling Capacity is calculated with matched blower coil and 25 ft. of OD interconnecting tubing.
EER is rated at AHRI conditions and in accordance with DOE test procedures.
5. Integrated Part Load Value is based on AHRI Standard 340/360 or 365. Units are rated at 80 F ambient,
80 F entering dry bulb, and 67 F entering wet bulb at AHRI rated CFM.
6. Sound Rating shown is tested in accordance with AHRI Standard 270,
7. Refer to refrigerant piping program for line sizing and line length.
8. Refrigerant (operating) charge is for condensing unit (all circuits) with matching blower coils and 25 ft.
of interconnecting refrigerant lines. All units are shipped with a small nitrogen holding charge only.
FLD = Furnished by Trane U.S. Inc. dba Trane / Equipment Proposal Page 7 of 18
Installed by Others
Unit Dimensions - Split System Air Conditioning Units (Large)
Item: Al Qty: 2
SERVICE PANEL
SEE NOTE 4
HAIL GUARD
(OPTIONAL)
SERVICE CLEARANCE
48" (SEE NOTE 2
FOR CLEARANCE)
NOTES:
1. ACCESS OPENING IS FOR FIELD INSTALLED BAYLOAM ACCESSORY.
2. MINIMUM CLEARANCE FOR PROPER OPERATION IS 36" FROM
WALLS, SHRUBBERY, PRIVACY FENCES ETC. MINIMUM CLEARANCE
BETWEEN ADJACENT UNITS IS 72". RECOMMENDED SERVICE
CLEARANCE 48"
3. TOP DISCHARGE AREA SHOULD BE UNRESTRICTED FOR 100"
MINIMUM. UNIT SHOULD BE PLACED SO ROOF RUN-OFF WATER DOES
NOT POUR .^.;RECTLY ON UNIT
4. OUTDOOR AIR TEMPERATURE SENSOR OPENING (DO NOT BLOCK OPENING)
HAIL GUARD
(OPTIONAL)
13/16" 36" —
41/4" WITH HAIL GUARD
LINE VOLTAGE 3315/16"—
x --CONTROL WIRING
■
36 3/8" SERVICE PANEL
2913/16"
0 5 5/81, 8 5/16"
1/16"
6.
LIQUID LINE 3 3/4"
21 11/16"
SUCTION LINE 37/16"
4(
SERVICE PANEL SIDE
z° S ?
6"
39
WITH HAIL GUARD
7/16" DIA. ISOLATOR MOUNTING
HOLES (OUTSIDE HOLES - 4 PLACES)
1 13/16"--1 1---27 11/16"------1 f --2 5/16"
6 - 7 1/2 TON HEAT PUMP CONDENSER (SINGLE COMPRESSOR)
DIMENSIONAL DRAWING
'ESS
FLD = Furnished by Trane U.S. Inc. dba Trane / Equipment Proposal Page 8 of 18
Installed by Others
Unit Dimensions - Split System Air Conditioning Units (Large)
Item: Al Qty: 2
AIR HANDLER ELECTRICAL DATA CONDENSER
ELECTRICAL DATA
EVAPORATOR FAN MOTOR 191
Convertible 460 Voltages
Convertible 460 Voltages
Model:
TWE090
TWE090
No.: 1 1
Unit Operating Voltage:
187-253
414-506
Volts: 208-230 460
Minimum Circuit Ampacity:
6.6-6.3
3.1
Phase: 3 3
Maximun Fuse Size:
15.0-15.0
15.0
Motor HP: 1.50 1.50
Maximun Circuit Breaker:
15.0-15.0
15.0
Amp -FLA: 5.3-5.0 2.5
Amp -LRA: 34.3-34.3 17.0
34.3-34.3
GENERALDATA
SYSTEM DATA
INDOOR COIL -TYPE
No. Refrigerant Circuits
1
Tude Size: '3/8"
Suction Line (in.) OD
1 1/8^
Face Area: 81/8"
Liquid Line (in.) OD
1/2"
Row/FPI 4/14
Refrigerant Control EXPANSION VALVE
Drain Connection Size 1" PVC
INDOOR FAN
FILTER
Type:
CENTRIFUGAL
Type: ' THROWAWAY
No. Used/Diameter x Width:
11 15"X15"
Furnished: YES
Drive Type/No. Speed:
BELT/ADJUSTABLE
No. Size Recommended: (3) 16"X25"X1"
CFM:
3000
No. Motor:
1
Motor HP - Standard/Oversized:
1.5 /2.0/3.0
Motor RPM:
1725
Motor Frame Size:
56H
HEATER DATA
ELECTRICAL DATA
Notes:
Heat Rating (kW):
11.25/14.96
1. KW ratings are at: 208/240V for 208-230V air handlers
Control Stages:
1
480V for 460V air handlers
Power Supply:
208-230/0/3
600V for 575V air handlers
Minimum Circuit Ampacity:
45.7/51.2
_voi�9a,_
Maximun Fuse Size:
50.0/60.0
For other than rated voltaoe, capacity = ( Rase VpRspe ) x z Rated Capacity
50.0/60.0
2. Any power supply and circuits must be wired and protected in accordance
Maximun Circuit Breaker:
11.25/14.96
with local electrical codes.
1
3. The HACR circuit breaker is for U.S.A. installations only.
208-230/0/3
45.7/51.2
50.0/60.0
50.0/60.0
NOTES:
1. Cooling performance is rated at 95 F ambient, 80 F entering dry bulb, 67 F entering wet bulb.
2. Gross capacity does not include the effect of fan motor heat. AHRI capacity is net and includes
the effect of fan motor heat. Ratings shown are tested and certified in accordance with AHRI
Standard 340/360 or 365 certification program.
3. Condensing Unit Only Gross Cooling Capacity rate at 45 F saturated suction temperature and
at 95 F ambient.
4. AHRI Net Cooling Capacity is calculated with matched blower coil and 25 ft. of OD interconnecting tubing.
EER is rated at AHRI conditions and in accordance with DOE test procedures.
5. Integrated Part Load Value is based on AHRI Standard 340/360 or 365. Units are rated at 80 F ambient,
80 F entering dry bulb, and 67 F entering wet bulb at AHRI rated CFM.
6. Sound Rating shown is tested in accordance with AHRI Standard 270.
7. Refer to refrigerant piping program for line sizing and line length.
8. Refrigerant (operating) charge is for condensing unit (all circuits) with matching blower coils and 25 ft.
of interconnecting refrigerant lines. All units are shipped with a small nitrogen holding charge only.
9. Second Column data Coverable to 460 volt
FLD = Fumished by Trane U. S. Inc. dba Trane / Equipment Proposal Page 9 of 18
Installed by Others
Unit Dimensions - Split System Air Conditioning Units (Large)
Item: Al Qty: 2
SUPPLY
OPEN -
47 1/2"
DUCT FLANGE
1" HEIGHT -
CONTROL WIRING
LINE VOLTAGE
CONTROLBOX
ACCESS PANEL
13/16" -
DRAIN CONNECTION
FOR HORIZONTAL
(SEE NOTE 2,3,5)
22 7/8"
54
FILTER ACCESS PAI
22" MIN. DISTANCE
BOTH SIDE
LIQUID LINE
SEE NOTES
NOTES:
1 PANEL DEPTH 1/2" (TYP.ALL PANELS).
2. REMOVABLE DRAIN PAN AND ATTACHED DRAIN CONNECTION MAY BE INSTALLED ON END
OF UNIT IN EITHER THE VERTICAL OR HORIZONTAL CONFIGURATION, PLASTIC DRAIN PAN
o- 70" ACCESS PLATE ON THE END OF UNIT OPPOSITE DRAIN CONNECTION MUST BE REMOVED TO
SLIDE DRAIN PAN OUT OF UNIT CLEANING. ACCESS PLATE MUST BE RE -INSTALLED AFTER
SLIDING DRAIN PAN BACK INTO UNIT.
3. IF PERIODIC DRAIN PAN CLEANING IS REQUIRED, ALLOW ROOM FOR PARTIAL REMOVAL OF
DRAIN PAN CONNECTION AT END OF UNIT.
4. 1" FEMALE SCHED. 40 PVC PIPE DRAIN CONNECTION VERTICAL CONFIGURATION.
11 11/16 5. 1" FEMALE SCHED. 40 PVC PIPE DRAIN CONNECTION HORIZONTAL CONFIGURATION,
24 1/16"
° A 161/16" A l SIDE RETURN A v
1 9/16" 1
2 3/4" 1 42" ,
x-31 /2"
6 13/16" COPPER LIQUID LINE
FIELDCONNECTION -
16"
COPPER SUCTION LINE
'//"�REMOTE BULB TXV F;ELD CONNECTION -
l-SUCTION LINE
1611/16" 17 7/16" 20 17 3/8"161j/16"
-3 5/8" 1 9/16"
-111116' 31/2"
- HOLE FOR
)RIZONTAL SUSPENSION
SUPPLY OPENING
BOTTC
FIL
SIDE_ -
SUPPLY VERTICAL - SUPPLY HORIZONTAL -
RETURN HORIZONTAL/ RETURN VERTICAL /
RETURN VERTICAL RETURN HORIZONTAL
7 1/2 TON AIR HANDLER (SINGLECIRCUIT)
NOTES 2,3,4
(4) HOLE FOR
HORIZONTAL
DIMENSIONAL DRAWING
FLD = Fumished by Trane U. S. Inc. dba Trane / Equipment Proposal Page 10 of 18
Installed by Others
Weight, Clearance & Rigging Diagram - Split System Air Conditioning Units (Large)
Item: Al Qty: 2
SERVICE PANEL
#2 #3
SERVICE PANEL
#1 #4
WEIGHTS AND LOAD POINT LOCATION
WEIGHT AND RIGGING
1/4" DIA. LIFTING
HOLES (4 PLACES)
WEIGHTS AND CORNER WEIGHTS
Shipping: 394.0 Ib
Net 340.0 Ib
Comer 1: 117.0 Ib
Comer 2: 86.0 Ib
Comer 3: 58.0 Ib
Comer 4: 79.0 Ib
FLD = Fumished by Trane U. S. Inc. dba Trane / Equipment Proposal Page 11 of 18
Installed by Others
Weight, Clearance & Rigging Diagram - Split System Air Conditioning Units (Large)
Item: Al Qty: 2
AIR FLOW
HORIZONTAL
I I
HORIZONTAL`
`\ RETURN `��\ AIRFLOW
RETURN
4 VERTICAL
VERTICAL RETURN
RETURN
WEIGHTS AND LOAD POINT LOCATION FOR CONDENSOR
WEIGHT AND RIGGING
FLD = Furnished by Trane U S. Inc. dba Trane / Equipment Proposal Page 12 of 18
Installed by Others
#1 WEIGHTS AND CORNER WEIGHTS
Shipping: 360.0 Ib
•
Net 323.0 Ib
VERTICAL
Corner 1: 67.0 Ib
Comer 2: 99.0 Ib
Comer 3: 75.0 Ib
Comer 4: 82.0 Ib
HORIZOTNAL
Comer A: 56.0 Ib
Corner B: 92.0 Ib
Comer C: 67.0 Ib
'Comer
0
0
D: 88.0 Ib
#2
#3
AIR FLOW
HORIZONTAL
I I
HORIZONTAL`
`\ RETURN `��\ AIRFLOW
RETURN
4 VERTICAL
VERTICAL RETURN
RETURN
WEIGHTS AND LOAD POINT LOCATION FOR CONDENSOR
WEIGHT AND RIGGING
FLD = Furnished by Trane U S. Inc. dba Trane / Equipment Proposal Page 12 of 18
Installed by Others
Accessory - Split System Air Conditioning Units (Large)
Item: Al Qty: 2
ELECTRIC HEATER
16"
15/16"
13 1/2"
2 7/16"
1 3/4"
16"
(12) 1/4" DIA HOLE
SAME PATTERN AS TOP
REMOVABLE
PANEL -
3 KNOCKOUT FOR 7/8". 13/8" AND 2"
DIA CONDUIT POWER SUPPLY ENTRY
7 1/2 TON ELECTRIC HEATER
DIMENSIONAL DRAWING
AIR HANDLER
(12) 1/4" DIA HOLE
SAME PATTERN AS TOP
—3013/161,
�{ 9/16"
—�
1/2"
30 3/4"
FLD = Fumished by Trane U.S. Inc. dba Trane / Equipment Proposal Page 13 of 18
Installed by Others
Field Wiring - Split System Air Conditioning Units (Large)
Item: Al Qty: 2
HEAT PUMP
OUTDOOR SECTION
B1
B2
Y
R
0
T
W
SI II II �� � ODT
II II II II
II II II I
II II II II
11 II IIL5L
r u u U, o
TO POWER SUPPLY
PER LOCAL CODES
ROOMTHERMOSTAT
R101 GI Yj W1 X21 BI T
I I I I
I I I I I I
I I I I I I I I
I I I I I I I I
I I I I I I I I
I I I I I I I I
I I I I I I I I
I I I I I I I I
I I I I I I I I
I I I I I I I I
I I I I I I I I
I I I I LI I I
IIIILIJ--
I I I b LTJ---�
V I I I rZZ-
f I -1 -I-� -7----
I -----rte- �--
i
JI
I
1ST STAGE HEAT
SEE NOTE 5
2ND STAGE HEAT
24 VAC COMMON
FAN
REVERSING VALVE
24 VAC
O.D. SENSOR
TYPICAL AIR HANDLER
I I LOW VOLTAGE TERMINAL BOARD
INTER -COMPONENT WIRING
f 24 VOLT FACTORY WIRING
l LINE VOLT
---- f24 VOLT FIELDWIRING
c==� LINE VOLT
NOTES:
1. POWER WIRING AND GROUNDING OF EQUIPMENT MUST COMPLY WITH LOCAL CODES.
2. BE SURE POWER SUPPLY AGREES WITH EQUIPMENT NAMEPLATE.
3. LOW VOW VOLTAGE WIRING TO BE 18 A.W.G. MINIMUM CONDUCTOR.
4. USE COPPER CONDUCTORS ONLY.
5. REMOVE JUMPER BETWEEN W1 AND W2 IF ODT ACCESSORY IS USED.
EDC
FLD = Fumished by Trane US. Inc. dba Trane / Equipment Proposal Page 14 of 18
Installed by Others
8/2/2016
City of Tukwila
Allan Ekberg, Mavor
Department of Community Development Jack Pace, Director
MARK TEMPLETON
1514 CENTRAL AVE S
KENT, WA 98032
RE: Permit No. M16-0035
FIRESTONE
215 ANDOVER PARK W
Dear Permit Holder:
In reviewing our current records, the above noted permit has not received a final inspection by the City of Tukwila Building
Division. Per the International Building Code, International Mechanical Code, Uniform Plumbing Code and/or the National Electric
Code, every permit issued by the Building Division under the provisions of these codes shall expire by limitation and become null
and void if the building or work authorized by such permit has not begun within 180 days from the issuance date of such permit, or if
the building or work authorized by such permit is suspended or abandoned at any time after the work has begun for a period of 180
days. Your permit will expire on 9/3/2016.
Based on the above, you are hereby advised to:
1) Call the City of Tukwila Inspection Request Line at 206-438-9350 to schedule for the next or final inspection. Each
inspection creates a new 180 day period, provided the inspection shows progress.
-or-
2) Submit a written request for permit extension to the Permit Center at least seven(7) days before it is due to expire.
Address your extension request to the Building Official and state your reason(s) for the need to extend your permit.
The Building Code does allow the Building Official to approve one extension of up to 180 days. If it is determined that your
extension request is granted, you will be notified by mail.
In the event you do not call for an inspection and/or receive an extension prior to 9/3/2016, your permit will become null and void
and any further work on the project will require a new permit and associated fees.
Thank you for your cooperation in this matter.
Sincerely,
Rachelle Ripley
Permit Technician
File No: M16-0035
6300 Southcenter Boulevard Suite 1#100 • Tukwila, Washington 98188 • Phone 206-431-3670 • Fax 206-431-3665
Complete Restaurant Repair
Home .Espanol Contact.
Safety & Health Claims & Insurance
4nWashington State Department of
Labor & Industrie
Complete Restaurant Repair
Owner or tradesperson PO BOX 203
KENT, WA98035
Principals 253-852-0624
Templeton, Michael Andrew, PRESIDENT KING County
BREWER, ELIZABETH
THERESA,SECRETARY
Doing business as
Complete Restaurant Repair
WA UBI No.
Business type
603 069 984
Corporation
Parent company
Governing persons
CRR INC
MICHAEL
Effective — expiration
ANDREW
03/2912011— 03/29/2017
TEMPLETON
Bond
.................
THOMAS MCELWRATH;
License
Page 1 of 3
A-7..Index Help MYLsd
Workplace Rights Trades & Licensing
Verify the contractor's active registration / license / certification (depending on trade) and any past violations.
Construction Contractor Active.
Meets current requirements.
License specialties
GENERAL
$1,000,000.00
License no.
COMPLRR893D9
Effective — expiration
Effective date
03/2912011— 03/29/2017
04/11/2015
Bond
.................
Expiration date
Lexon Ins Co
$12,000.00
Bond account no.
9804899
Received by L&I
Effective date
03/29/2011
03/29/2011
Expiration date
Until Canceled
Insurance
.................
Country Mutual Ins Co
$1,000,000.00
Policy no.
AB9122759
Received by L&I
Effective date
04/15/2015
04/11/2015
Expiration date
04/11/2016
Insurance history
Savings
.........._.......
No savings accounts during the previous 6 year period.
https:Hsecure.Ini.wa.gov/verify/Detail.aspx?UBI=603069984&LIC=COMPLRR893D9&SAW= 3/7/2016