HomeMy WebLinkAboutPermit M16-0035 - FIRESTONE - TRANE TOP UNITSFIRESTONE 215 ANDOVER PARK W EXPIRED 0.9/03/16 M16-0035 City of Tukwila Department of Community Development • 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-438-9350 Web site: http://www.TukwilaWA.Rov MECHANICAL PERMIT Parcel No: 9202470070 Permit Number: M16-0035 Address: 215 ANDOVER PARK W Issue Date: 3/7/2016 WA Cities Electrical Code: 2014 Permit Expires On: 9/3/2016 Project Name: FIRESTONE 2014 Owner: 2012 WA State Energy Code: Name: JC PENNY CORP INC 2012 Address: PO BOX 10001 TAX DEPT M/S 1217, Permit Center Authorized Signature: DALLAS, WA, 75301 Date: Contact Person: Name: MARKTEMPLETON Phone: (253) 797-5008 Address: 1514 CENTRAL AVE 5, KENT, WA, 98032 Contractor: Name: COMPLETE RESTAURANT REPAIR Phone: (253) 852-0624 Address: PO BOX 203, KENT, WA, 98035 License No: COMPLRR893D9 Expiration Date: 3/29/2017 Lender: Name: Address: DESCRIPTION OF WORK: REMOVE TWO 7.5 TON AIR HANDLERS AND 7.5 TON CONDENSERS AND INSTALL TWO NEW TRANE 7.5 TON UNITS. Valuation of Work: $0.00 Fees Collected: $367.45 Type of Work: REPLACEMENT Electrical Service Provided by: PUGET SOUND ENERGY Fuel type: ELECT Water District: TUKWILA Sewer District: TUKWILA SEWER SERVICE Current Codes adopted by the City of Tukwila: International Building Code Edition: 2012 National Electrical Code: 2014 International Residential Code Edition: 2012 WA Cities Electrical Code: 2014 International Mechanical Code Edition: 2012 WAC 296-4613: 2014 Uniform Plumbing Code Edition: 2012 WA State Energy Code: 2012 International Fuel Gas Code: 2012 Permit Center Authorized Signature: (i(/ Date: I hearby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this development permit and agree to the conditions attached to this permit. Signature: Date Print Name: Ar /C-/ This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: ***MECHANICAL PERMIT CONDITIONS*** 2: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431-3670). 3: All permits, inspection record card and approved construction documents shall be kept at the site of work and shall be open to inspection by the Building Inspector until final inspection approval is granted. 4: Manufacturers installation instructions shall be available on the job site at the time of inspection. 5: Except for direct -vent appliances that obtain all combustion air directly from the outdoors; fuel -fired appliances shall not be located in, or obtain combustion air from, any of the following rooms or spaces: Sleeping rooms, bathrooms, toilet rooms, storage closets, surgical rooms. 6: Equipment and appliances having an ignition source and located in hazardous locations and public garages, PRIVATE GARAGES, repair garages, automotive motor -fuel dispensing facilities and parking garages shall be elevated such that the source of ignition is not less than 18 inches above the floor surface on which the equipment or appliance rests. 7: Type 1 Hoods, the required grease duct leakage test and Ilight test shall be performed by a special inspection and testing agency in accordance with I.M.C. Chapter 5. PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 1800 MECHANICAL FINAL 0701 ROUGH -IN MECHANICAL CITY OF TUKWILA Community Development Department Permit Center • 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.Tukwi]aWA.izov SITE LOCATION Mechanical Permit No. 1D — Project No. Date Application Accepted: Date Application Expires: use MECHANICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **please print** King Co Assessor's Tax No.: 920247007007 Site Address: 215 Andover Park W Tukwila WA 98188 Suite Number: Floor: Tenant Name: Firestone New Tenant: ❑ .....Yes ®..No PROPERTY OWNER Name: JC Penny Corp Inc Address: PO Box 10001 City: Dallas State: TX Zip: 75301 CONTACT PERSON — person receiving all project communication Name: Mark Templeton Address: 1514 Central Ave S City: Kent State: WA Zip: 98032 Phone: (253) 797-5008 Fax: Email: mark@completerestaurantrepair.com Valuation of project (contractor's bid price): $ 19,500 Describe the scope of work in detail: MECHANICAL CONTRACTOR INFORMATION Company Name: CRR Address: PO Box 203 City: Kent State: WA Zip: 98035 Phone: (800) 509-4105 Fax: Contr Reg No.: COMPLRR893D9 Exp Date: 03/29/2017 Tukwila Business License No.: Remove two 7.5 ton air handlers and 7.5 ton condensers and install two new Trane 7.5 ton units. Use: Residential: New .......... ❑ Replacement ........ ❑ Commercial: New .......i@w Replacement ........ m Fuel Type: Electric..... 0 Gas ....... ❑ Other:_ H:\Applications\Porm-Applications On Line\2016 ApplicationsWechanical Permit Application Revised 14-16.docx Revised: January 2016 Page 1 of 2 bh Indicate type of mechanical work being installed and the quantity below: Unit Type Qty Furnace <100k btu 2 Furnace >100k btu 2 Floor furnace 1 Suspended/wall/floor mounted heater 57 dB(A) Appliance vent Commercial Repair or addition to heat/refrig/cooling system 47 dB(A) Air handling unit <10,000 cfrn 65 dB(A) Unit Type Qty Air handling unit >I0,000 cfm 2 Evaporator cooler 2 Ventilation fan connected to single duct 1 Ventilation system 57 dB(A) Hood and duct Commercial Incinerator — domestic 47 dB(A) Incinerator — comm/industrial 65 dB(A) Unit Type Qty Fire damper Residential, Nighttime Diffuser 2 Thermostat 1 Wood/gas stove 57 dB(A) Emergency enerator Commercial Other mechanical equipment 47 dB(A) 60 dB(A) 65 dB(A) Boiler/Compressor Qty 0-3 hp/100,000 btu Residential, Nighttime 3-15 h /500,000 btu 2 15-30 hp/1,000,000 btu 55 dB(A) 30-50 hp/1,750,000 btu 57 dB(A) 50+ hp/1,750,000 btu Commercial 57 dB(A) 47 dB(A) 60 dB(A) 65 dB(A) Noise: Mechanical units need to be in compliance with the Tukwila Noise Code. Maximum permissible sound levels are based on from where the sound is created and where the sound is heard. Additionally, if sound can be heard from within a house at night in a residential zone it may not be allowed. For more details, see TMC 8.22 District of Sound Producing Source District of Receiving Property Residential, Daytime* Residential, Nighttime Commercial Industrial Residential 55 dB(A) 45 dB(A) 57 dB(A) 60 dB(A) Commercial 57 dB(A) 47 dB(A) 60 dB(A) 65 dB(A) Industrial 60 dB(A) 50 dB(A) 65 dB(A) 70 dB(A) *Daytime means 7AM-1OPM, Monday through Friday and 8AM-IOPM, Saturday, Sunday and State -recognized holidays. A few sounds are exempt from the noise code, including: Warning devices; Construction and property maintenance during the daytime hours (lam-IOpm); Testing of backup generators during the day. PERMIT APPLICATION NOTES - Value of construction — in all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the permit center to comply with current fee schedules. Expiration of plan review — applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The building official may grant one extension of time for additional periods not to exceed 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT BUILDING OWNER Print Name: Mailing Address: Date: / S� /Day Telephone: 2e,0C - r 3 / 07/j "JT City D� State Zip H:4lppliwtions\Forms-Applications On Line\2016 Applicatiou\Mechanical Permit Application Revised 14-16.docx Revised: January 2016 Page 2 of 2 bh DESCRIPTIONS ACCOUNT QUANTITY PAID PermitTRAK $367.45 M16-0035 Address: 215 ANDOVER PARK W Apn: 9202470070 $367.45 MECHANICAL $349.95 PERMIT ISSUANCE BASE FEE R000.322.100.00.00 0.00 $32.50 PERMIT FEE R000.322.100.00.00 0.00 $317.45 TECHNOLOGY FEE $17.50 TECHNOLOGY FEE TOTAL FEES PAID BY RECEIPT: R7844 R000.322.900.04.00 0.00 $17.50 $367.45 Date Paid: Monday, March 07, 2016 Paid By: ADVANCED HOME Pay Method: CREDIT CARD 07032G Printed: Monday, March 07, 2016 12:52 PM 1 of 1 I?WSYS7EMS Mechanical Specifications - Split System Air Conditioning Units (Large) Item: Al Qty: 2 General - TWA Weatherproofed Steel Mounting/Lifting Rails Hermetic Scroll Compressors Plate Fin Condenser Coils Fans and Motors Standard Operating Range 50-125F (Min. 0°F with Low Ambient Accy) Nitrogen Holding Charge Certified and Rated in Accordance with AHRI and DOE Standards Certified to UL 1995 Casing - TWA Zinc Coated, Heavy Gauge, Galvanized Steel Weather Resistant Baked Enamel Finish Meets 672 hr Salt Spray Test Removable Single Side Maintenance Access Panels Lifting Handles in Maintenance Access Panels Unit Base Provisions for Forklift and/or Crane Lifting Refrigeration System - TWA Single Compressor (TWA073D, TWA090D, TWA120D) Single Refrigeration Circuit with Integral Subcooling Circuit. Single Direct Drive Hermetic Scroll Compressor with Centrifugal Oil Pump Providing Lubrication To Moving Parts Suction Gas -Cooled Motor w/ t 10% Voltage Utilization Range of Unit Nameplate Voltage Reversing Valve Crankcase Heater Internal Temperature and Current Sensitive Motor Overloads No Compressor Suction and/or Discharge Valves (Reduced Vibration/Sound) Factory Installed Liquid Line Filter Drier Phase Loss/Reverse Rotation Monitor Liquid Line Service Valve (with gauge port) Suction Line Service Valve (with gauge port) External High Pressure Cutout Device External Low Pressure Cutout Device Evaporator Defrost Control Loss of Charge Protection (Discharge Line Thermostat) Condenser Coil - TWA 3/8" Internally Enhanced Copper Tube Mechanically Bonded to Lanced Aluminum Plate Fins Factory Pressure and Leak Tested to 660 psig. Condenser Fan - TWA 26" or 28" Propeller Fan(s) Direct Drive Statically and Dynamically Balanced Condenser Motor(s) - TWA Permanently Lubricated Totally Enclosed or Open Construction Built -In Current and Thermal Overloads Ball or Sleeve Bearing Type Controls - TWA Centralized MicroProcessor Indoor and Outdoor Temperature Sensors Drive Algorithms Making Decisions for All Heating, Cooling, and Ventilation Integrated Anti -Short Cycle Timer Integrated Time Delay Between Compressors Completely Internally Wired Numbered and Colored Wires Contactor Pressure Lugs or Terminal Block Unit External Mounting Location for Disconnect Device Single Point Power Entry FLD = Furnished by Trane U.S. Inc. dba Trane / Equipment Proposal Page 4 of 18 Installed by Others General - TWE Completely Factory Assembled Convertible for Horizontal or Vertical Configuration Convertible for Cooling Only or Heat Pump Application Convertible for Left or Right External Connections (Refrigerant and/or Electrical) Convertible for Front or Bottom Air Return Nitrogen Holding Charge Certified and Rated in Accordance with AHRI and DOE Standards Certified to UL 1995 for Indoor Blower Coil Units Casing - TWE Zinc Coated, Heavy Gauge, Galvanized Steel Weather Resistant Baked Enamel Finish Access Panels with Captive Screws Completely Insulated with Foil Faced, Cleanable, Fire Retardant, Permanent, Odorless Glass Fiber Material Captured or Sealed Insulation Edges Electrical Connection Bushings or Plugs Refrigerant Connection Bushings or Plugs Withstand Elevated Internal Static Pressure Refrigeration System - TWE Single or Dual Circuit Distributor(s) Thermal Expansion Valves (TXVs) Evaporator Coil - TWE 3/8" Internally Enhanced Copper Tube Mechanically Bonded to Lanced Aluminum Plate Fins Factory Pressure and Leak Tested to 449 psig. Draw -Through Airflow Dual Circuits Are Interlaced/Intertwined Double Sloped, Removable, Cleanable, Composite Drain Pan Four Drain Pan Positions Indoor Fan - TWE Double Inlet, Double Width, Forward Curved, Centrifugal Type Fan Dual Fans On 10.4-20.912.5-25 Ton Air Handlers Adjustable Belt Drive Permanently Lubricated Bearings Indoor Motor - TWE Adjustable Motor Sheaves Fixed Motors Sheaves (SZVAV and 2 -Speed VFD) Thermal Overload Protection Permanently Lubricated Bearings Meet Energy Policy of 1992 (EPACT) Optional Over Sized Motors for High Static Applications Controls - TWE Completely Internally Wired Numbered and Colored Wires Magnetic Indoor Fan Contactor Low Voltage Terminal Strip Single Point Power Entry Evaporator Defrost Control Filters - TWE Access From Side Coil Panels Filters Slide on Rack One Inch (1"), Throw -Away Filters on 4.6-8.335-10 Ton Units Filter Rack Convertible to Two Inch (2") Capability on 5-10 Ton Units Two Inch (2"), Throw -Away Filters on 10.4-20.912.5-25 Ton Units FLD = Furnished by Trane U.S. Inc. dba Trane / Equipment Proposal Page 5 of 18 Installed by Others Electric Heaters - TWE Heavy Duty Nickel Chromium Elements cETL Approved Installs Directly On Fan Discharge One or Two Stage Control (Dependent Upon Capacity) Single Point Power Entry Terminal Strip Connections 460V Heaters Internally Wye Connected Automatic Line Break High Limit Controls 230V Heaters Internally Delta Connected Automatic Reset of High Limit Controls Through Pilot Duty with Secondary Backup Fuse Links FLD = Furnished by Trane U.S. Inc. dba Trane / Equipment Proposal Page 6 of 18 Installed by Others Unit Dimensions - Split System Air Conditioning Units (Large) Item: Al Qty: 2 ELECTRICAL DATA CONDENSER 'ELECTRICAL DATA COMPRESSOR MOTOR CONDENSER FAN MOTOR Model: TWA090D4 No.: '1 No.: 1 Unit Operating Voltage: 414-506 Volts: 460 Volts: 460 Minimum Circuit Ampacity: 17.9 Phase: 3 Phase: 1 Maximun Fuse Size: 25.0 Amp-RLA: 13.0 Amp -FLA: 1.6 Maximun Circuit Breaker: 25.0 Amp -LRA: 100.0 Amp -LRA: 3.8 GENERAL DATA CONDENSER COOLING PERFORMANCE (1)(2)(3)(4)(5) COMPRESSOR Matched Air Handler: .93,000 Number. .1 Condensing Unit Only: 86,000 ARI Net Cooling Capacity: 90,000 Motors/HP (each): 6.9 11 0 Motor RPM: 3500 Matched Air Handler (EER): 12.2 No. Compressor/ Tons: 1/6.9 Condensing Unit Only (EER): N/A System Integrated Part Load Value (IPLV): N/A Condensing Unit Only (I PLV): 8.18 SYSTEM DATA 1�) System KW 7.05 '1 Condensing Unit KW: 9 No. Refrigerant Circuits: Suction Line (in.) OD: 1 3/8" Liquid Line (in.) OD: 5/8" System IEER: 11.7 OUTDOOR COIL OUTDOOR FAN Tube Size (in.) OD •3/8" No. Used/Diameter (in.): '1 / 26" Face Area (sq. ft.) 19 1/4" Drive Type/No. Speeds: DIRECT / 1 Rows/FPI 2/18 CFM: 6,530 No. Motors/HP: 1/0.5 Motor RPM: 1,100 REFRIGERANT CHARGE (Fld Supplied) (n(e) TYPE: R410A (Circuits #1): 19.6 Ib (Circuits #2): N/A NOTES: 1. Cooling performance is rated at 95 F ambient, 80 F entering dry bulb, 67 F entering wet bulb. Gross capacity does not include the effect of fan motor heat. AHRI capacity is net and includes the effect of fan motor heat. Ratings shown are tested and certified in accordance with AHRI 2. Standard 340/360 or 365 certification program. 3. Condensing Unit Only Gross Cooling Capacity rate at 45 F saturated suction temperature and at 95 F ambient. 4. ARI Net Cooling Capacity is calculated with matched blower coil and 25 ft. of OD interconnecting tubing. EER is rated at AHRI conditions and in accordance with DOE test procedures. 5. Integrated Part Load Value is based on AHRI Standard 340/360 or 365. Units are rated at 80 F ambient, 80 F entering dry bulb, and 67 F entering wet bulb at AHRI rated CFM. 6. Sound Rating shown is tested in accordance with AHRI Standard 270, 7. Refer to refrigerant piping program for line sizing and line length. 8. Refrigerant (operating) charge is for condensing unit (all circuits) with matching blower coils and 25 ft. of interconnecting refrigerant lines. All units are shipped with a small nitrogen holding charge only. FLD = Furnished by Trane U.S. Inc. dba Trane / Equipment Proposal Page 7 of 18 Installed by Others Unit Dimensions - Split System Air Conditioning Units (Large) Item: Al Qty: 2 SERVICE PANEL SEE NOTE 4 HAIL GUARD (OPTIONAL) SERVICE CLEARANCE 48" (SEE NOTE 2 FOR CLEARANCE) NOTES: 1. ACCESS OPENING IS FOR FIELD INSTALLED BAYLOAM ACCESSORY. 2. MINIMUM CLEARANCE FOR PROPER OPERATION IS 36" FROM WALLS, SHRUBBERY, PRIVACY FENCES ETC. MINIMUM CLEARANCE BETWEEN ADJACENT UNITS IS 72". RECOMMENDED SERVICE CLEARANCE 48" 3. TOP DISCHARGE AREA SHOULD BE UNRESTRICTED FOR 100" MINIMUM. UNIT SHOULD BE PLACED SO ROOF RUN-OFF WATER DOES NOT POUR .^.;RECTLY ON UNIT 4. OUTDOOR AIR TEMPERATURE SENSOR OPENING (DO NOT BLOCK OPENING) HAIL GUARD (OPTIONAL) 13/16" 36" — 41/4" WITH HAIL GUARD LINE VOLTAGE 3315/16"— x --CONTROL WIRING ■ 36 3/8" SERVICE PANEL 2913/16" 0 5 5/81, 8 5/16" 1/16" 6. LIQUID LINE 3 3/4" 21 11/16" SUCTION LINE 37/16" 4( SERVICE PANEL SIDE z° S ? 6" 39 WITH HAIL GUARD 7/16" DIA. ISOLATOR MOUNTING HOLES (OUTSIDE HOLES - 4 PLACES) 1 13/16"--1 1---27 11/16"------1 f --2 5/16" 6 - 7 1/2 TON HEAT PUMP CONDENSER (SINGLE COMPRESSOR) DIMENSIONAL DRAWING 'ESS FLD = Furnished by Trane U.S. Inc. dba Trane / Equipment Proposal Page 8 of 18 Installed by Others Unit Dimensions - Split System Air Conditioning Units (Large) Item: Al Qty: 2 AIR HANDLER ELECTRICAL DATA CONDENSER ELECTRICAL DATA EVAPORATOR FAN MOTOR 191 Convertible 460 Voltages Convertible 460 Voltages Model: TWE090 TWE090 No.: 1 1 Unit Operating Voltage: 187-253 414-506 Volts: 208-230 460 Minimum Circuit Ampacity: 6.6-6.3 3.1 Phase: 3 3 Maximun Fuse Size: 15.0-15.0 15.0 Motor HP: 1.50 1.50 Maximun Circuit Breaker: 15.0-15.0 15.0 Amp -FLA: 5.3-5.0 2.5 Amp -LRA: 34.3-34.3 17.0 34.3-34.3 GENERALDATA SYSTEM DATA INDOOR COIL -TYPE No. Refrigerant Circuits 1 Tude Size: '3/8" Suction Line (in.) OD 1 1/8^ Face Area: 81/8" Liquid Line (in.) OD 1/2" Row/FPI 4/14 Refrigerant Control EXPANSION VALVE Drain Connection Size 1" PVC INDOOR FAN FILTER Type: CENTRIFUGAL Type: ' THROWAWAY No. Used/Diameter x Width: 11 15"X15" Furnished: YES Drive Type/No. Speed: BELT/ADJUSTABLE No. Size Recommended: (3) 16"X25"X1" CFM: 3000 No. Motor: 1 Motor HP - Standard/Oversized: 1.5 /2.0/3.0 Motor RPM: 1725 Motor Frame Size: 56H HEATER DATA ELECTRICAL DATA Notes: Heat Rating (kW): 11.25/14.96 1. KW ratings are at: 208/240V for 208-230V air handlers Control Stages: 1 480V for 460V air handlers Power Supply: 208-230/0/3 600V for 575V air handlers Minimum Circuit Ampacity: 45.7/51.2 _voi�9a,_ Maximun Fuse Size: 50.0/60.0 For other than rated voltaoe, capacity = ( Rase VpRspe ) x z Rated Capacity 50.0/60.0 2. Any power supply and circuits must be wired and protected in accordance Maximun Circuit Breaker: 11.25/14.96 with local electrical codes. 1 3. The HACR circuit breaker is for U.S.A. installations only. 208-230/0/3 45.7/51.2 50.0/60.0 50.0/60.0 NOTES: 1. Cooling performance is rated at 95 F ambient, 80 F entering dry bulb, 67 F entering wet bulb. 2. Gross capacity does not include the effect of fan motor heat. AHRI capacity is net and includes the effect of fan motor heat. Ratings shown are tested and certified in accordance with AHRI Standard 340/360 or 365 certification program. 3. Condensing Unit Only Gross Cooling Capacity rate at 45 F saturated suction temperature and at 95 F ambient. 4. AHRI Net Cooling Capacity is calculated with matched blower coil and 25 ft. of OD interconnecting tubing. EER is rated at AHRI conditions and in accordance with DOE test procedures. 5. Integrated Part Load Value is based on AHRI Standard 340/360 or 365. Units are rated at 80 F ambient, 80 F entering dry bulb, and 67 F entering wet bulb at AHRI rated CFM. 6. Sound Rating shown is tested in accordance with AHRI Standard 270. 7. Refer to refrigerant piping program for line sizing and line length. 8. Refrigerant (operating) charge is for condensing unit (all circuits) with matching blower coils and 25 ft. of interconnecting refrigerant lines. All units are shipped with a small nitrogen holding charge only. 9. Second Column data Coverable to 460 volt FLD = Fumished by Trane U. S. Inc. dba Trane / Equipment Proposal Page 9 of 18 Installed by Others Unit Dimensions - Split System Air Conditioning Units (Large) Item: Al Qty: 2 SUPPLY OPEN - 47 1/2" DUCT FLANGE 1" HEIGHT - CONTROL WIRING LINE VOLTAGE CONTROLBOX ACCESS PANEL 13/16" - DRAIN CONNECTION FOR HORIZONTAL (SEE NOTE 2,3,5) 22 7/8" 54 FILTER ACCESS PAI 22" MIN. DISTANCE BOTH SIDE LIQUID LINE SEE NOTES NOTES: 1 PANEL DEPTH 1/2" (TYP.ALL PANELS). 2. REMOVABLE DRAIN PAN AND ATTACHED DRAIN CONNECTION MAY BE INSTALLED ON END OF UNIT IN EITHER THE VERTICAL OR HORIZONTAL CONFIGURATION, PLASTIC DRAIN PAN o- 70" ACCESS PLATE ON THE END OF UNIT OPPOSITE DRAIN CONNECTION MUST BE REMOVED TO SLIDE DRAIN PAN OUT OF UNIT CLEANING. ACCESS PLATE MUST BE RE -INSTALLED AFTER SLIDING DRAIN PAN BACK INTO UNIT. 3. IF PERIODIC DRAIN PAN CLEANING IS REQUIRED, ALLOW ROOM FOR PARTIAL REMOVAL OF DRAIN PAN CONNECTION AT END OF UNIT. 4. 1" FEMALE SCHED. 40 PVC PIPE DRAIN CONNECTION VERTICAL CONFIGURATION. 11 11/16 5. 1" FEMALE SCHED. 40 PVC PIPE DRAIN CONNECTION HORIZONTAL CONFIGURATION, 24 1/16" ° A 161/16" A l SIDE RETURN A v 1 9/16" 1 2 3/4" 1 42" , x-31 /2" 6 13/16" COPPER LIQUID LINE FIELDCONNECTION - 16" COPPER SUCTION LINE '//"�REMOTE BULB TXV F;ELD CONNECTION - l-SUCTION LINE 1611/16" 17 7/16" 20 17 3/8"161j/16" -3 5/8" 1 9/16" -111116' 31/2" - HOLE FOR )RIZONTAL SUSPENSION SUPPLY OPENING BOTTC FIL SIDE_ - SUPPLY VERTICAL - SUPPLY HORIZONTAL - RETURN HORIZONTAL/ RETURN VERTICAL / RETURN VERTICAL RETURN HORIZONTAL 7 1/2 TON AIR HANDLER (SINGLECIRCUIT) NOTES 2,3,4 (4) HOLE FOR HORIZONTAL DIMENSIONAL DRAWING FLD = Fumished by Trane U. S. Inc. dba Trane / Equipment Proposal Page 10 of 18 Installed by Others Weight, Clearance & Rigging Diagram - Split System Air Conditioning Units (Large) Item: Al Qty: 2 SERVICE PANEL #2 #3 SERVICE PANEL #1 #4 WEIGHTS AND LOAD POINT LOCATION WEIGHT AND RIGGING 1/4" DIA. LIFTING HOLES (4 PLACES) WEIGHTS AND CORNER WEIGHTS Shipping: 394.0 Ib Net 340.0 Ib Comer 1: 117.0 Ib Comer 2: 86.0 Ib Comer 3: 58.0 Ib Comer 4: 79.0 Ib FLD = Fumished by Trane U. S. Inc. dba Trane / Equipment Proposal Page 11 of 18 Installed by Others Weight, Clearance & Rigging Diagram - Split System Air Conditioning Units (Large) Item: Al Qty: 2 AIR FLOW HORIZONTAL I I HORIZONTAL` `\ RETURN `��\ AIRFLOW RETURN 4 VERTICAL VERTICAL RETURN RETURN WEIGHTS AND LOAD POINT LOCATION FOR CONDENSOR WEIGHT AND RIGGING FLD = Furnished by Trane U S. Inc. dba Trane / Equipment Proposal Page 12 of 18 Installed by Others #1 WEIGHTS AND CORNER WEIGHTS Shipping: 360.0 Ib • Net 323.0 Ib VERTICAL Corner 1: 67.0 Ib Comer 2: 99.0 Ib Comer 3: 75.0 Ib Comer 4: 82.0 Ib HORIZOTNAL Comer A: 56.0 Ib Corner B: 92.0 Ib Comer C: 67.0 Ib 'Comer 0 0 D: 88.0 Ib #2 #3 AIR FLOW HORIZONTAL I I HORIZONTAL` `\ RETURN `��\ AIRFLOW RETURN 4 VERTICAL VERTICAL RETURN RETURN WEIGHTS AND LOAD POINT LOCATION FOR CONDENSOR WEIGHT AND RIGGING FLD = Furnished by Trane U S. Inc. dba Trane / Equipment Proposal Page 12 of 18 Installed by Others Accessory - Split System Air Conditioning Units (Large) Item: Al Qty: 2 ELECTRIC HEATER 16" 15/16" 13 1/2" 2 7/16" 1 3/4" 16" (12) 1/4" DIA HOLE SAME PATTERN AS TOP REMOVABLE PANEL - 3 KNOCKOUT FOR 7/8". 13/8" AND 2" DIA CONDUIT POWER SUPPLY ENTRY 7 1/2 TON ELECTRIC HEATER DIMENSIONAL DRAWING AIR HANDLER (12) 1/4" DIA HOLE SAME PATTERN AS TOP —3013/161, �{ 9/16" —� 1/2" 30 3/4" FLD = Fumished by Trane U.S. Inc. dba Trane / Equipment Proposal Page 13 of 18 Installed by Others Field Wiring - Split System Air Conditioning Units (Large) Item: Al Qty: 2 HEAT PUMP OUTDOOR SECTION B1 B2 Y R 0 T W SI II II �� � ODT II II II II II II II I II II II II 11 II IIL5L r u u U, o TO POWER SUPPLY PER LOCAL CODES ROOMTHERMOSTAT R101 GI Yj W1 X21 BI T I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I LI I I IIIILIJ-- I I I b LTJ---� V I I I rZZ- f I -1 -I-� -7---- I -----rte- �-- i JI I 1ST STAGE HEAT SEE NOTE 5 2ND STAGE HEAT 24 VAC COMMON FAN REVERSING VALVE 24 VAC O.D. SENSOR TYPICAL AIR HANDLER I I LOW VOLTAGE TERMINAL BOARD INTER -COMPONENT WIRING f 24 VOLT FACTORY WIRING l LINE VOLT ---- f24 VOLT FIELDWIRING c==� LINE VOLT NOTES: 1. POWER WIRING AND GROUNDING OF EQUIPMENT MUST COMPLY WITH LOCAL CODES. 2. BE SURE POWER SUPPLY AGREES WITH EQUIPMENT NAMEPLATE. 3. LOW VOW VOLTAGE WIRING TO BE 18 A.W.G. MINIMUM CONDUCTOR. 4. USE COPPER CONDUCTORS ONLY. 5. REMOVE JUMPER BETWEEN W1 AND W2 IF ODT ACCESSORY IS USED. EDC FLD = Fumished by Trane US. Inc. dba Trane / Equipment Proposal Page 14 of 18 Installed by Others 8/2/2016 City of Tukwila Allan Ekberg, Mavor Department of Community Development Jack Pace, Director MARK TEMPLETON 1514 CENTRAL AVE S KENT, WA 98032 RE: Permit No. M16-0035 FIRESTONE 215 ANDOVER PARK W Dear Permit Holder: In reviewing our current records, the above noted permit has not received a final inspection by the City of Tukwila Building Division. Per the International Building Code, International Mechanical Code, Uniform Plumbing Code and/or the National Electric Code, every permit issued by the Building Division under the provisions of these codes shall expire by limitation and become null and void if the building or work authorized by such permit has not begun within 180 days from the issuance date of such permit, or if the building or work authorized by such permit is suspended or abandoned at any time after the work has begun for a period of 180 days. Your permit will expire on 9/3/2016. Based on the above, you are hereby advised to: 1) Call the City of Tukwila Inspection Request Line at 206-438-9350 to schedule for the next or final inspection. Each inspection creates a new 180 day period, provided the inspection shows progress. -or- 2) Submit a written request for permit extension to the Permit Center at least seven(7) days before it is due to expire. Address your extension request to the Building Official and state your reason(s) for the need to extend your permit. The Building Code does allow the Building Official to approve one extension of up to 180 days. If it is determined that your extension request is granted, you will be notified by mail. In the event you do not call for an inspection and/or receive an extension prior to 9/3/2016, your permit will become null and void and any further work on the project will require a new permit and associated fees. Thank you for your cooperation in this matter. Sincerely, Rachelle Ripley Permit Technician File No: M16-0035 6300 Southcenter Boulevard Suite 1#100 • Tukwila, Washington 98188 • Phone 206-431-3670 • Fax 206-431-3665 Complete Restaurant Repair Home .Espanol Contact. Safety & Health Claims & Insurance 4nWashington State Department of Labor & Industrie Complete Restaurant Repair Owner or tradesperson PO BOX 203 KENT, WA98035 Principals 253-852-0624 Templeton, Michael Andrew, PRESIDENT KING County BREWER, ELIZABETH THERESA,SECRETARY Doing business as Complete Restaurant Repair WA UBI No. Business type 603 069 984 Corporation Parent company Governing persons CRR INC MICHAEL Effective — expiration ANDREW 03/2912011— 03/29/2017 TEMPLETON Bond ................. THOMAS MCELWRATH; License Page 1 of 3 A-7..Index Help MYLsd Workplace Rights Trades & Licensing Verify the contractor's active registration / license / certification (depending on trade) and any past violations. Construction Contractor Active. Meets current requirements. License specialties GENERAL $1,000,000.00 License no. COMPLRR893D9 Effective — expiration Effective date 03/2912011— 03/29/2017 04/11/2015 Bond ................. Expiration date Lexon Ins Co $12,000.00 Bond account no. 9804899 Received by L&I Effective date 03/29/2011 03/29/2011 Expiration date Until Canceled Insurance ................. Country Mutual Ins Co $1,000,000.00 Policy no. AB9122759 Received by L&I Effective date 04/15/2015 04/11/2015 Expiration date 04/11/2016 Insurance history Savings .........._....... No savings accounts during the previous 6 year period. https:Hsecure.Ini.wa.gov/verify/Detail.aspx?UBI=603069984&LIC=COMPLRR893D9&SAW= 3/7/2016