Loading...
HomeMy WebLinkAboutPermit M16-0036 - SALAL CREDIT UNION - AIR DUCTWORK AND GRILLESSALAL CREDIT UNION M16-0036 M City of Tukwila Department of Community Development • 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-438-9350 Web site: http://www.TukwilaWA.gov Parcel No: 0005800037 Address: 690 STRANDER BLVD 2 Project Name: SALAL CREDIT UNION MECHANICAL PERMIT Permit Number: M16-0036 Issue Date: 5/4/2016 Permit Expires On: 10/31/2016 Owner: Name: Address: WA, Contact Person: Name: PETER CRELLEY Phone: (206) 361-0071 Address: PO BOX 33370, SEATTLE, WA, 98133 Contractor: Name: PRO STAFF MECHANICAL INC Phone: (206) 361-0071 Address: PO BOX 33370, SEATTLE, WA, 98133 License No: PROSTMI072NG Expiration Date: 7/2/2016 Lender: Name: Address: DESCRIPTION OF WORK: NEW SUPPLY AIR DUCTWORK & GRILLES PER PLAN. TWO NEW IN-LINE EXHAUST FANS. THREE NEW ZONE DAMPERS. Valuation of Work: $20,500.00 Fees Collected: $468.00 Type of Work: NEW Electrical Service Provided by: PUGET SOUND ENERGY Fuel type: ELECT Water District: TUKWILA Sewer District: TUKWILA SEWER SERVICE Current Codes adopted by the City of Tukwila: International Building Code Edition: 2012 National Electrical Code: 2014 International Residential Code Edition: 2012 WA Cities Electrical Code: 2014 International Mechanical Code Edition: 2012 WAC 296-46B: 2014 Uniform Plumbing Code Edition: 2012 WA State Energy Code: 2012 International Fuel Gas Code: 2012 Permit Center Authorized Sign ature;��' Date: QS/dyllt_ M I hearby certify that I have read and examined this permit and know the same to be trt and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this development permit and ag1ree to the conditions attached to this permit. Signatu Print N Date: -5 `4 6 This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: The attached set of mechanical plans have been reviewed by The Tukwila Fire Marshals Office and are acceptable with the following concerns: 2: H.V.A.C. units rated at greater than 2,000 cfm require auto -shutdown devices. These devices shall be separately zoned in the alarm panel and local U.L. central station supervision is required. (City Ordinance #2437) 3: H.V.A.C. systems supplying air in excess of 2,000 cubic feet per minute to enclosed spaces within buildings shall be equipped with an automatic shutoff. Automatic shutoff shall be accomplished by interrupting the power source of the air -moving equipment upon detection of smoke in the main return -air duct served by such equipment. Smoke detectors shall be labeled by an approved agency for air -duct installation and shall be installed in accordance with the manufacturer's installation instructions. (IMC 606.1, 606.2.1) 4: Remote indicator lights are required on all above ceiling smoke detectors. (City Ordinance #2437) 5: Duct smoke detectors shall be capable of being reset from a single point near the alarm panel. (City Ordinance #2437) 6: Duct detectors shall send a supervisory signal only upon activation. (City Ordinance #2437) 7: All new fire alarm systems or modifications to existing systems shall have the written approval of The Tukwila Fire Prevention Bureau. No work shall commence until a fire department permit has been obtained. (City Ordinance #2437) (IFC 901.2) 8: An electrical permit from the City of Tukwila Building Department Permit Center (206-431-3670) is required for this project. 9: Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (City Ordinances #2436 and #2437) 10: Any overlooked hazardous condition and/or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. 11: These plans were reviewed by Inspector 511. If you have any questions, please call Tukwila Fire Prevention Bureau at (206)575-4407. 12: Work shall be installed in accordance with the approved construction documents, and any changes made during construction that are not in accordance with the approved construction documents shall be resubmitted for approval. 13: All permits, inspection record card and approved construction documents shall be kept at the site of work and shall be open to inspection by the Building Inspector until final inspection approval is granted. 14: All construction shall be done in conformance with the Washington State Building Code and the Washington State Energy Code. 15: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of this requirement. 16: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206-431-3670). 17: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center. 18: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 19: `MECHANICAL PERMIT CONDITIONS' 20: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431-3670). 21: Manufacturers installation instructions shall be available on the job site at the time of inspection. PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 1400 FIRE FINAL 1800 MECHANICAL FINAL 0609 PIPE/DUCT INSULATION 0701 ROUGH -IN MECHANICAL CITY OF TUKWILA Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.TukwilaWA.gov SITE LOCATION Mechanical Permit No. Project No. Date Application Accepted: (? JC) Date Application Expires: !1 '7.p (0 use MECHANICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. "please print" 6� v King Co Assessor's Tax No.: 000� C OO 3% Site Address: �� `� lAND� (Z 9 LV/D. Suite Number: Floor: Tenant Name: S AL A L CRL P l 1 V KI o► -k New Tenant: ❑ .....Yes .No PROPERTY OWNER Company Name. Name• Address Address: iz io E. f Ste. 3 O City: T _ State: W/A- zip' CONTACT PERSON — person receiving all project communication Name: ,Z Address: Box S33-70 City` — State* Zi 3 Phone: —Z x:�b —3o— Email: J MECHANICAL CONTRACTOR INFORMATION Company Name. —S Address 3Mj 0 City: State: Zi qne —00 [.tr 3`1—�fi� C Reg 05IN� 21� G Exp Date: 2 r Tukwila Business License No.: Vc Valuation of project (contractor's bid price): $ 2-0 Solo Vo 14 Describe the scope of work in detail: NLk/ .Se.,PpL\ ,/� i,z 17v cT►✓otc-r � G>z 1 t,�s 'P P- 2 PORN„ -TWJ' 1"4C --IA/ 1N -LI Nr r--,cIAAL.A ;5 A T:>AmpF—::7 )ze Use: Residential: New .......... ❑ Replacement ........ ❑ Commercial: New ......... Replacement ........ ❑ Fuel Type: Electric.... Gas....... ❑ Other: H:Wpplieations\Forms-Applications On Line\1016 ApplicationsW echanical Permit Application Revised 113-16.docx Revised: January 2016 Page 1 of 2 bh Indicate type of mechanical work being installed and the quantity below: Unit Type Qty Furnace <100k btu Residential, Nighttime Furnace >I OOk btu Industrial Floor furnace 55 dB(A) Suspended/wall/floor mounted heater 57 dB(A) Appliance vent Commercial Repair or addition to heat/refrig/cooling system 47 dB(A) Air handling unit <10,000 cfm 65 dB(A) Unit Type Qty Air handling unit >I0,000 cfm Residential, Nighttime Evaporator cooler Industrial Ventilation fan connected to single duct 55 dB(A) Ventilation system 57 dB(A) Hood and duct Commercial Incinerator — domestic 47 dB(A) Incinerator — comm/industrial 65 dB(A) Unit Type Qty Fire damper Residential, Nighttime Diffuser Industrial Thermostat 55 dB(A) Wood/gas stove 57 dB(A) Emergency enerator Commercial Other mechanical equipment 47 dB(A) 60 dB(A) 65 dB(A) Boiler/Compressor Qty 0-3 hp/100,000 btu 3-15 h /500,000 btu 15-30 hp/1,000,000 btu 30-50 hp/1,750,000 btu 50+hp/1,750,000 btu Noise: Mechanical units need to be in compliance with the Tukwila Noise Code. Maximum permissible sound levels are based on from where the sound is created and where the sound is heard. Additionally, if sound can be heard from within a house at night in a residential zone it may not be allowed. For more details, see TMC 8.22 District of Sound Producing Source District of Receiving Property Residential, Daytime* Residential, Nighttime Commercial Industrial Residential 55 dB(A) 45 dB(A) 57 dB(A) 60 dB(A) Commercial 57 dB(A) 47 dB(A) 60 dB(A) 65 dB(A) Industrial 60 dB(A) 50 dB(A) 65 dB(A) 70 dB(A) *Daytime means 7AM-IOPM, Monday through Friday and 8AM-IOPM, Saturday, Sunday and State -recognized holidays. A few sounds are exempt from the noise code, including: Warning devices; Construction and property maintenance during the daytime hours (lam -I Opm); Testing of backup generators during the day. PERMIT APPLICATION NOTES - Value of construction — in all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the permit center to comply with current fee schedules. Expiration of plan review — applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The building official may grant one extension of time for additional periods not to exceed 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING AU ZED AGENT: Signature: Date: 3/7 / G ff Print N Day Telephone: Z06— 3:61— 00%1 Mailing Address: 20. _9� 333-7 R CJ F A j 14 WA 9013775 City State Zip H:\Applicatiom\Forms-Applications On Line\_1016 ApplicationsWechanical Permit Application Revised IA-16.docx Revised: January 2016 Page 2 of 2 bh DESCRIPTIONS PermitTRAK • QUANTITY PAID $592.53 EL16-0201 Address: 640 STRANDER BLVD Apn: 0005800037 $124.53 ELECTRICAL $118.60 PERMIT FEE MULTI-FAM/COMM 11000.322.101.00.00 0.00 $118.60 TECHNOLOGY FEE $5.93 TECHNOLOGY FEE R000.322.900.04.00 0.00 $5.93 M16-0036 Address: 640 STRANDER BLVD Apn:0005800037 $468.00 MECHANICAL $450.00 PERMIT ISSUANCE BASE FEE R000.322.100.00.00 0.00 $32.50 PERMIT FEE R000.322.100.00.00 0.00 $327.50 PLAN CHECK FEE R000.322.102.00.00 0.00 $90.00 TECHNOLOGY FEE $18.00 TECHNOLOGY FEE R000.322.900.04.00 0.00 $18.00 TOTAL PAID . Date Paid: Monday, March 07, 2016 Paid By: PRO -STAFF MECHANICAL INC Pay Method: CHECK 15622 Printed: Monday, March 07, 2016 3:51 PM 1 of 1 11!14FYSlfml INSPECTION RECORD Retain a copy with permit - 00360 INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project: /�1LAL &tM/T- WICIV Type of Inspection: aN rlA[AL Address: 1140 1Rvl� Date Called: Special Instructions: Date Wan te/: /G .m. P-rrr Requested/• I Phone No: 9 Approved per applicable codes. u Corrections required prior to approval. REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. INSPECTION RECORD 2 Retain a copy with permit 1"M(6-003 INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 AV Projec : - Type of In ec�johi D sL S SA1 A dre� : � � ` B d U toqSpecial Date Calle Instructions: ^ „ /pA/( Date Wanted' a.m. & / p.m. Requester: Phone No: REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit �Ocl 3,6 - INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 RUQ —k Aq Pr je t: Type of Ins ectio . aej Address.- ���� Date Called: gq 0 J Special Instructions: 4� Date Wanet,_d;,. � a.m. 5 J�n` p.m. Requester: PjI.no i�d�f Phone No: 3604H-0-77 ` (Inspector: Z_c / IUate: 5_v 2,4- —tb REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. 4 i INSPECTION NUMBER INSPECTION RECORD Retain a copy with permit �,i6- o 7 69 PERMIT NUMBERS CITY OF TUKWILA FIRE DEPARTMENT 206-575-4407 Project: Type of ,Insp ction: Address:, t �- .ft-fi'�'r- � a Contact Person: Suite #: Pre -Fire: Special Instructions: Phone No.: R --Approved per applicable codes. Corrections required prior to approval. V COMMENTS: ✓eT ol. Needs Shift Inspection: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: Inspector: , S:: Date: -)1;c6J ib Hrs.: $100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. Billing Address Attn: Company Name: Address: City: State: Zip: Word/Inspection Record Form.Doc 3/14/14 T.F.D. Form F.P. 113 Le® �qes sha'i r� r�:1de 1O tha 3 of rk Zvi#hc ; rrior V'�_ v21 of Tu%wiia Guilding Division. �+ {�{� N 1 E: i :^_ i's;c.nz; vAl rcq,_,,irc a rises �,i{c'1, �7 n ilwi ftl and may in;,fude adc5b=1 plan revie vi ices. j LOCATION MAPS G 4 C is subject t�o�yw rS and oo- T .3. l drnnentw 't9'_�� i n ate.. c..;.L3 #:sViCg�_9�:,IID.:u k5W dc�o; r�+►^ rc�. of appfav-: C.aid - �y end cc, :' a� nc 'cd �Z-A. J D a - W.5' LI�1G LEGAL D ESCRI PTI I�r � ` ' ���''� S DIVO ADDRESS: 640 STRANDER BLVD 98188 PARCEL #: 0005800037 LEGAL DESCRIPTION: MEADER HENRY D -C #46 LOT 1 OF CITY OF TUKWILA SHORT Discharge PLAT NO 84 -31 -SS RECORDING NO 8501030748 SD SHORT PLAT Service Make DAF - POR NW 1/4 OF SEC 25-23-04 - BAAP ON WLY R/W LN OF MODEL WEST VALLEY HWY SR 181 AT A PT WCH BEARS S 81-07-31 W 50 CFM Noise FT FR C/L THOF AT HWY ENGR STA 160+00 TH FR SD POB ALG Diameter SD WLY R/W LN S 12-18-30 E 205.45 FT TAP WCH BEARS S Break Room 108PPanasonic 81-07-31 W 35 FT FR CIL AT HWY ENGR STA 162+50 TH S FV-20NLF1 05-15-06 E 112.35 FT TH TANGENT TO PRECEDING COURSE ALG 200 CFM 1.4 ARC OF CURVE TO RGT RAD 50 FT & A C/A OF 86-22-37 ARC 6"1P1 LENGTH 75.38 FT TAP ON NLY R/W LN OF STRANDER BLVD TH ALG SD NLY R/W LN TANGENT TO PRECEDING CURVE S 81-07-31 mLLE W 28.58 FTTH TANGENT TO PRECEDING COURSE ALG ARC OF @ 0.4"s.p. Sones CURVE TO LFT RAD 70 FT & C/A OF 19-33-22 ARC LENGTH W ? E 5 c 238.92 FT TH TANGENT TO PRECEDING CURVE S 61-34-09 W TO Gather 103 INTSN OF SD NLY R/W LN OF STRANDER BLVD WITH ELY BANK FV-40NLF1 OF GREEN RIVER TH NLY ALG SD ELY BANK TO INTSN WITH SLY 408 CFM 1.4 @ 0.4 s.p. Sones LN OF BOW LAKE P/L R/W 30 FT WIDE TH ALG SD SLY LN S 8"0 87-12-48 E 194.01 FT TAP ON WLY R/W LN OF SD WEST VALLEY HWY TH ALG SD WLY R/W LN S 08-52-29 E 165.06 FT TO TPOB HVAC T.I. SCOPE OF WORK: ♦ Associated new ductwork distribution systems, ductwork insulation, diffusers and grilles. ♦ New return air duct smoke detectors for RTU -1 & 2. ♦ ZD 1-3: Supply & install three new Jackson Systems stand-alone modulating zone dampers. ■ ZD -1: 8" O Hotelling 110 ■ ZD -2: 8"0,, Hotelling 109 ■ ZD -3: 8"0 Break Room 108 ■ Includes new wall mounted adjustable thermostats with digital display. ♦ Supply & install two new inline Panasonic exhaust fans. ■ EF -1 = Break Room 108, Restrooms 104 & 105; EF -1 to be interlocked to the thermostat of RTU -1 and to run during occupied hours. ■ EF -2 = Gather 103; EF -2 to be interlocked to a wall mounted cooling only wall mounted thermostat. ■ Both exhaust fans to be terminated through the roof with motorized back -draft dampers. ♦ Supply & install two new Honeywell commercial VisionPro 7 -Day programmable thermostats. ♦ Equipment start-up & test, Commissioning, Air Balance. EXHAUST FAN SCHEDULE Exhaust Fan Notes: 1. Terminate exhaust fans up through roof and maintain 10' clearance from outside air intake openings. 'F\�I=�__ _ 2. Each exhaust termination to have a motorized back -draft damper. Dampers sh l l ad a 1 1Pu00R I leakage rate of 4 CFM/ft2 at 1.0 w.g. UUU t�f` W&LIAI,CE 3. EF -1: Interlock to the thermostat of RTU -2. EF -1 to run continuously during oc lupieckhburs � 4. EF -2: Line voltage solid-state thermostat provided by PSMI and mounted and W" fired h�At( �' Ta y2016 electrical contractor. AJ gr HVAC T.I. CONSTRUCTION NOTES: City of Tukwila 1) ALL NEW & EXISTING EXHAUST, SUPPLY & RETURN DUCT ON RTU 1-2 TO BE LOW-PRESSURE (x:5 'SULDING DIVISIOk ' 2) ALL SUPPLY & RETURN AIR DUCTWORK TO BE INSULATED AND SEALED PER CODE. -- 3) ALL NEW EQUIPMENT COMMISSIONING TO INCLUDE BUT NOT LIMITED TO:EF 1-2, ZD 1-3) & ASSOCIATED IMITTETOD CONTROLS TO BE COMMISSIONED PER SECT. C408.2 OF TEH�� Qq SEC. a) POINT TO POINT CONNECTION AND VERIFICAITON OF CONTROL WIRING & SYSTEMS. CITY OF T UKWILA b) EQUIPMENT START-UP & TEST. c) AIR BALANCING. MIG%- PAR 07 2016 d) PERFORMANCE TESTING. e) OPERATION & MAINTENANCE MANUALS. f) ON-SITE OWNER/TENANT TRAINING. PERMIT CENTER g) COMMISSIONING COMPLIANCE CHECKLIST: FIGURE C408.1.2.1 OF THE WSEC. s V C a Electrical Discharge TAG Service Make Type MODEL Control CFM Noise (120 -Volt) Diameter EF -1 Break Room 108PPanasonic Inline FV-20NLF1 Interlock 200 CFM 1.4 0.46 Amps 6"1P1 mLLE w/RTU-2 @ 0.4"s.p. Sones m W ? E 5 c EF -2 Gather 103 Inline FV-40NLF1 T -stat 408 CFM 1.4 @ 0.4 s.p. Sones 1.10 Amps 8"0 Exhaust Fan Notes: 1. Terminate exhaust fans up through roof and maintain 10' clearance from outside air intake openings. 'F\�I=�__ _ 2. Each exhaust termination to have a motorized back -draft damper. Dampers sh l l ad a 1 1Pu00R I leakage rate of 4 CFM/ft2 at 1.0 w.g. UUU t�f` W&LIAI,CE 3. EF -1: Interlock to the thermostat of RTU -2. EF -1 to run continuously during oc lupieckhburs � 4. EF -2: Line voltage solid-state thermostat provided by PSMI and mounted and W" fired h�At( �' Ta y2016 electrical contractor. AJ gr HVAC T.I. CONSTRUCTION NOTES: City of Tukwila 1) ALL NEW & EXISTING EXHAUST, SUPPLY & RETURN DUCT ON RTU 1-2 TO BE LOW-PRESSURE (x:5 'SULDING DIVISIOk ' 2) ALL SUPPLY & RETURN AIR DUCTWORK TO BE INSULATED AND SEALED PER CODE. -- 3) ALL NEW EQUIPMENT COMMISSIONING TO INCLUDE BUT NOT LIMITED TO:EF 1-2, ZD 1-3) & ASSOCIATED IMITTETOD CONTROLS TO BE COMMISSIONED PER SECT. C408.2 OF TEH�� Qq SEC. a) POINT TO POINT CONNECTION AND VERIFICAITON OF CONTROL WIRING & SYSTEMS. CITY OF T UKWILA b) EQUIPMENT START-UP & TEST. c) AIR BALANCING. MIG%- PAR 07 2016 d) PERFORMANCE TESTING. e) OPERATION & MAINTENANCE MANUALS. f) ON-SITE OWNER/TENANT TRAINING. PERMIT CENTER g) COMMISSIONING COMPLIANCE CHECKLIST: FIGURE C408.1.2.1 OF THE WSEC. 0 0 POO • TT� V1 CS oMj z � U. o Q H t~J z U _ W LLx�� FOXY. to 0 � a] =, 0 w a a)C.N 2 U J U REVISIONS DRAWN PC DATE February 29, 2016 CONTENTS Job #1800 SHEEP NUMBER N =-1 s V C a •E mLLE H"s m W ? E 5 c O a N Q: E Mmoo �O o = 1 a U a .c NEA NO. U # 0 0 POO • TT� V1 CS oMj z � U. o Q H t~J z U _ W LLx�� FOXY. to 0 � a] =, 0 w a a)C.N 2 U J U REVISIONS DRAWN PC DATE February 29, 2016 CONTENTS Job #1800 SHEEP NUMBER N =-1 EG2:6"x6" EG2:6"x6" REPAIR & PATCH 60 CFM 70 CFM EXISTING 10"0 1� ROOF PENETRATION CD -2: 6"x6" GVVB 30 CFM a HVAC DRAWING NOTES: , '-o"AFF (2-TYP) STO 6G RESTROOM RESTR� RTU = ROOFTOP UNIT EF = EXHAUST FAN ZD = ZONE DAMPER CD = CEILING DIFFUSER LS =LINEAR SLOT EGl • 22" 10" RG = RETURN GRILLE x N N 190 CFM EG = EXHAUST GRILLE oPEN To ABovE M 6 TG = TRANSFER GRILLE oO TYP = TYPICAL I \ O = THERMOSTAT EF-1--� -- �- CD-1: 8' 150 CFM NEW 10"0 EXHAUST TERMINATION 8'-0" AFF FROM EF -2 UP THROUGH ROOF �G OG WITH MOTORIZED BACK -DRAFT DAMPER BREAK ROOM 1U0 g ZD -3 OB 8"0 APC -2 8'-6" AFF ZD -2 - - g„0 U Z RG -1 22"xlO" (2-TYP) LS -2: 4' 2 -SLOT 130 CFM HVAC T.I. PLAN SCALE: 1/8"=1'-0” AFF 8'-6"AFF HOTELLING LS -2: 4'- 2 -SLOT 200 CFM GWB , 'FB' -6- AFF INANCIAZD-1 SERV C SL VO 111 I I SCS -1 8'-6"AFF a� e RG -1 LS -1: 4' RTU -2: EXISTING 3 -TON 22"x22" 3 -SLOT 2640 CFM 230 CFM 3ROOFTOP PACKAGED APC.1 (2-TYP) LS -3: 4' HEAT PUMP s'-s^AFF 4 -SLOT -SET MINIMUM OUTSIDE AIR RETURN AIR i scs-1 I DAMPER TO 170 CFM GATHER400 CFM 8'-6"AFF 10 -INSTALL NEW RETURN AIR 3 _ DUCT SMOKE DETECTOR - LS -3: 4' —� > TG -14 -SLOT 22"xl O" EF -2 EXHAUST AIR OB I O r -EF -2 QB II L013Y� DQB DI OB I LS -1: 4' 4 -SLOT 350 CFM I OB a FM ® V F �G OG =o•= OB OB M v N y V m 3 O ® y 0 =o•= C •� M v N y V m 3 a i C N•= U Z �LL•� yO O m W Y G}mmol =o C C E m x >y t7 N vtf cavi c¢ c0.7 120z U 1 aW Z v¢ o a S2 a' z a LUn H n Nt=.1 ��a 2U. ao u- cc M W m M ■ y X0 �c Z(L o y t- N N a A6N N ua.d NEW 10"0 EXHAUST TERMINATION FROM EF -1 UP THROUGH ROOF WITH MOTORIZED BACK -DRAFT DAMPER GWB 8'-0" AFF � ►�j ATM O SERVICE RM • 0 -CD-1:6"D y APC -2 100 CFM 8'-6" AFF pS.. �iI WED FOR MPL ANCE LS -1: 4' 12'TyA,pRpVED ►v 3 -SLOT ( • 250 CFM ENTRY MAR !� 2 5 2016 101^y SLS -1: 4' 14 -SLOT City of ila 400 CFM BUILDING DIVISION (2-TYP) RECEIVED CITY OF TUKWILA MAR 07 2016 PERMIT CENTER i C� RTU -1: EXISTING 4 -TON ROOFTOP PACKAGED HEAT PUMP -SET MINIMUM OUTSIDE AIR DAMPER TO 245 CFM -INSTALL NEW RETURN AIR DUCT SMOKE DETECTOR REVISIONS W MM4 OD �,3 o x DRAWN PC DATE February 29, 2016 CONTENTS SHEET NUMBER Job #1800 A/--.-2 NEW 10"0 ROOF EXHAUST TERMINATION FROM EF -1 PATCH EXISTING 10"0 EXHAUST ROOF PENETRATION HVAC ROOF PLAN r NEW 10"0 ROOF EXHAUST TERMINATION FROM EF -2 REVIEWED FOR CODE COMPLIANCE APPROVED MAR 2 5 2016 City of Tukwila BUILDING DIVISION REVISIONS DRAWN PC DATE February 29, 2016 CITY OF TUKWILA MARp CONTENTS MAR 0 /ry 2016 Job #1800 PERMIT CENTER SHEET NUMBER .N ---m3 s 21 U C W m C U Z E a o� N o2 U NN W NC o a U at REVISIONS DRAWN PC DATE February 29, 2016 CITY OF TUKWILA MARp CONTENTS MAR 0 /ry 2016 Job #1800 PERMIT CENTER SHEET NUMBER .N ---m3 PERMIT COORS COPY PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: M16-0036 PROJECT NAME: SALAL CREDIT UNION SITE ADDRESS: 640 STRANDER BLVD DATE: 03/07/16 X Original Plan Submittal Revision # before Permit Issued Response to Correction Letter # Revision # DEPARTMENTS: ftj 00 111V Building Division ❑ Am 14w(- vl4-10 Fire Prevention ❑ after Permit Issued Planning Division ❑ Public Works ❑ Structural ❑ Permit Coordinator ❑ PRELIMINARY REVIEW: DATE: 03/08/16 Not Applicable ❑ Structural Review Required ❑ (no approval/review required) REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: DUE DATE: 04/05/16 Approved ❑ Approved with Conditions ❑ Corrections Required ❑ Denied ❑ (corrections entered in Reviews) (ie: Zoning Issues) Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: 12/18/2013 PRO STAFF MECHANICAL INC 40*4 Washington State Department of k.1 Labor & Industries Page 1 of 2 Home Lspanol Contact Search L&I A -L Index help My L&I Safety & Health Claims & Insurance Workplace Rights Trades & Licensing PRO STAFF MECHANICAL INC Owner or tradesperson PO BOX 33370 SEATTLE, WA 98133 Principals 206-361-0071 ALMO, LEONARD LEE, PRESIDENT KING County ALMO, PENNY H, VICE PRESIDENT Doing business as PRO STAFF MECHANICAL INC WA UBI No. Business type 601 038 859 Corporation Governing persons LEONARD ALMO PENNY H ALMO; License Verify the contractor's active registration / license / certification (depending on trade) and any past violations. Construction Contractor ......................................................... _.......... Active. Meets current requirements. License specialties GENERAL License no. PROSTMI072NG Effective — expiration 08/07/1993— 07/02/2016 Bond DEVELOPERS SURETY & INDEM CO $12,000.00 Bond account no. 799707C Received by L&I Effective date 01/26/2009 01/14/2009 Expiration date Until Canceled Insurance ............................ American Economy Insurance Co $1,000,000.00 Policy no. 26CCO06951 Received by L&I Effective date 06/22/2015 06/30/2014 Expiration date 06/30/2016 Insurance history Savings ................. No savings accounts during the previous 6 year period. https:Hsecure.Ini.wa.gov/verify/Detail.aspx?UBI=601038859&LIC=PROSTMI072NG&SAW= 5/4/2016