Loading...
HomeMy WebLinkAboutPermit M16-0038 - MULTICARE - RTU, DUCT AND RESTROOM EXHAUST FANSMULTICARE 17275 SOUTHCENTER PKWY 160 M16-0038 City of Tukwila Department of Community Development • 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-438-9350 Web site: http://www.Tukwi[aWA.Rov MECHANICAL PERMIT Parcel No: 2623049063 Permit Number: M16-0038 Address: 17275 SOUTHCENTER PKWY 160 Issue Date: 3/29/2016 Permit Expires On: 9/25/2016 Project Name: MULTICARE Owner: Name: MASAO 2012 Address: 117 E LOUISA #230 C/O SCR LLC, 2014 SEATTLE, WA, 98102 2012 Contact Person: 2014 Name: TERESE ANDERSON Phone: (253) 796-5825 Address: 1221 SECOND AVE N, KENT, WA, 2014 98032 2012 Contractor: 2012 Name: HERMANSON COMPANY LLP Phone: (206) 575-9700 Address: 1221 2ND AVE N, KENT, WA, 98032- 2945 License No: HERMACLO05BJ Expiration Date: 8/25/2016 Lender: Name: Address: DESCRIPTION OF WORK: TIE INTO 2 EXISTING RTU'S AND DUCT TO NEW TENANT LAYOUT. ADD 2 EXHAUST FANS FOR RESTROOM EXHAUST Valuation of Work: $30,000.00 Fees Collected: $585.58 Type of Work: REPLACEMENT Electrical Service Provided by: PUGET SOUND ENERGY Fuel type: ELECT Water District: TUKWILA Sewer District: TUKWILA SEWER SERVICE Current Codes adopted by the City of Tukwila: International Building Code Edition: 2012 National Electrical Code: 2014 International Residential Code Edition: 2012 WA Cities Electrical Code: 2014 International Mechanical Code Edition: 2012 WAC 296-466: 2014 Uniform Plumbing Code Edition: 2012 WA State Energy Code: 2012 International Fuel Gas Code: 2012 Permit Center Authorized Signature: I hearby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this development permy a •awe to the conditions attached to this permit. Signature: Print Nam Dater 2216 This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: Work shall be installed in accordance with the approved construction documents, and any changes made during construction that are not in accordance with the approved construction documents shall be resubmitted for approval. 2: All permits, inspection record card and approved construction documents shall be kept at the site of work and shall be open to inspection by the Building Inspector until final inspection approval is granted. 3: All construction shall be done in conformance with the Washington State Building Code and the Washington State Energy Code. 4: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206-431-3670). 5: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center. 6: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 7: `MECHANICAL PERMIT CONDITIONS' 8: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431-3670). 9: Manufacturers installation instructions shall be available on the job site at the time of inspection. PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 1800 MECHANICAL FINAL 0609 PIPE/DUCT INSULATION 0701 ROUGH -IN MECHANICAL CITY OF TUKWILA Community Development Department • Permit Center • 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.TukwilaWA.Pov Mechanical Permit No. M I [,1— QV Project No. Date Application Accepted: Date Application Expires: 9 !3�L Q use MECHANICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **please print** SITE LOCATION :A King Co Assessor's Tax No.: 2623049063 Site Address: 17275 Southcenter Pkwy Suite Number: Floor: Tenant Name: Multicare New Tenant: 0.....Yes ❑..No PROPERTY OWNER Name: Multicare Health Systems Address: 315 Martin Luthar King Way City: Tacoma State: WA Zip: 98415 CONTACT PERSON — person receiving all project communication Name: Terese Anderson Address: 1221 2nd Ave N City: Kent State: WA Zip: 98032 Phone: (206) 200-7804 Fax: Email: tanderson@hermanson.com Valuation of project (contractor's bid price): $ 30,000 Describe the scope of work in detail: MECHANICAL CONTRACTOR INFORMATION Company Name: Hermanson Company Address: 1221 2nd Ave N City: Kent State: wA Zip: 98032 Phone: (206) 200-7804 Fax: Contr Reg No.: HERMACLO05BJ Exp Date: 08/16/2016 Tukwila Business License No.: BUS -0994464 Tie into two existing RTUs and duct to new tenent layout. Add 2 exhaust fans for restroom exhaust. Use: Residential: New .......... ❑ Replacement ........ ❑ Commercial: New .......... ❑ Replacement ........ ❑ Fuel Type: Electric..... ❑ Gas....... ❑ Other:_ HdApplicationfforms-Applications On Linet2011 Applications\Mcchaniwl Permit Application Rmscd 8-9-11.docx Revised: August 2011 Pagel of 2 bb Indicate type of mechanical work being installed and the quantity below: Unit Type Qty Furnace <I 00k btu Furnace >I 00k btu Floor furnace Suspended/wall/floor mounted heater Appliance vent Repair or addition to heat/refhg/cooling system Air handling unit <10,000 cfm Unit Type Qty Air handling unit >I0,000 cfm Evaporator cooler Ventilation fan connected to single duct Ventilation system Hood and duct Incinerator — domestic Incinerator— comm/industrial PERMIT APPLICATION NOTES - Unit Type Qty Fire damper Diffuser Thermostat Wood/gas stove Emergency enerator Other mechanical equipment Boiler/Compressor Qty 0-3 hp/100,000 btu 3-15 h /500,000 btu 15-30 hp/1,000,000 btu 30-50 hp/1,750,000 btu 50+hp/l, 50,000 btu Value of construction — in all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the permit center to comply with current fee schedules. Expiration of plan review — applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The building official may grant one extension of time for additional periods not to exceed 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR Date: 03/08/2016 Print Name: TereSe Anderson Day Telephone: (206) 200-7804 Mailing Address: 1221 2nd Ave N Kent WA 98032 City State Zip H:WpplicationskForms-Applications On Line\2011 Applicatiom\Mmhanical Permit Appliwlion Revised 8-9-1 I.docx Rmscd: August 2011 Page 2 of 2 bh DESCRIPTIONS PermitTRAK ACCOUNT QUANTITY PAID $1,112.74 M16-0038 Address: 17275 SOUTHCENTER PKWY BLDG Apn: 2623049063 $585.58 MECHANICAL $563.06 PERMIT ISSUANCE BASE FEE R000.322.100.00.00 0.00 $32.50 PERMIT FEE R000.322.100.00.00 0.00 $417.95 PLAN CHECK FEE R000.322.102.00.00 0.00 $112.61 TECHNOLOGY FEE $22.52 TECHNOLOGY FEE R000.322.900.04.00 0.00 $22.52 PG16-0029 Address: 17275 SOUTHCENTER PKWY BLDG Apn: 2623049063 $527.16 PLUMBING $506.88 PERMIT ISSUANCE BASE FEE R000.322.100.00.00 0.00 $32.50 PERMIT FEE R000.322.100.00.00 0.00 $373.00 PLAN CHECK FEE R000.322.103.00.00 0.00 $101.38 TECHNOLOGY FEE $20.28 TECHNOLOGY FEE TOTAL FEES PAID R000.322.900.04.00 0.00 $20.28 Date Paid: Tuesday, March 08, 2016 Paid By: TERESE ANDERSON Pay Method: CREDIT CARD 989771 Printed: Tuesday, March 08, 2016 2:45 PM 1 of 1 SYSTEMS INSPECTION RECORD Retain a copy with permit I M41 4J 30 INSP ON N0. PERMIT N0. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project: Type of Inspection: Address: Date Called: Special Instructions: Date Wantd:/ p.m. Requester: Phone No: Approved per applicable codes. tl Corrections required prior to approval. fZ//(� REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION RECORD Vr , 6; Retain a copy with permitFM-16 003 INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project: fA rZ r- Type I-1 of In. pection: W- vC?' 4J9(A-A1TA.1 Address: 17v Cta�lll? Date Called: Special Instructions: Date Wanted: Requester. Phone No: AApproved per applicable codes. 11 Corrections required prior to approval. Inspector: REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit ml& -o638 INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project: Tyl2e of Inspection/: QC N Address: Date Called: J-7z75'-SA11)4(6JrM 1, Special Instructions: Date Wanted: At; Requester: —y e LAN Phone No: WC - 2S -T-- 3 s-9 Approved per applicable codes. L._.! Corrections required prior to approval. REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION RECORD�Ad0 �� Retain a copy with permit i'lV ECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 981 (206 431-3§70 Permit Inspection Request Line (206) 438-9350 0 Project Type of Insp cti �,: f��/r/�e G � ddress. Date Called: 2,15- f6jc t. `- Special Instructions: DateantQd;a.m. 9 GG��JJ p.m. Requester: 11 R Phone 6 2--y-5- 00 1 L'7 1L'7 Inspector: Date: 6-2-3 _ f / REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. r AHRTEST Co., Inns.. Preliminary Test and Balance Report FIRM: Airtest Co Inc PO Box 86 Issaquah, WA 98027 PHONE: 425-313-0172 FAX: 425-313-5735 PROJECT: Urgent Care 17272 Southcenter Parkway Tukwila, WA 98188 DATE: 8/10/2016 CONTACT: Luke Holmen NOTES: Airtest Cc Inc PROJECT #: 16-3067-1 Preliminary TAB Report RECEIVED CITY OF TUKWILA AUS 17 2016 PERMIT CENTER 1 of 7 AIRIEST Co., Inc. r(Ej gg Roof Top Unit PROJECT: Urgent Care DATE: 8/10/2016 LOCATION: Tukwila, WA CONTACT: Luke Holmen PROJECT M 16-3067-1 SYSTEM/UNIT: RTU -1 AREA: Staff 123 Unit Data Unit Manufacturer Trane Unit Model Number YSC060A3RLA015U Unit Serial Number 647102800L RTU -1 /Supply Fan 1075 RPM Fan Type / Class FC / 1 Test Data Actual Ext. SP Suction -0.37 in. we Actual Ext. SP Discharge 0.30 in. we Actual Total Ext. SP 0.67 in. we Fan SP In Actual -0.70 in. we Fan SP Out Actual 0.30 in. we Act. Tot. SP 1.00 in. we RTU -1 / Supply Fan Direct Drive Fan RPM Actual 1010 RPM A. Tot. Inlet SP -0.70 in. wc. A. Tot. Discharge SP 0.30 in. wc. TSP Actual 1.00 in. wc. Electrical Test Data RTU -1 / Supply Fan Filter Manufacturer Final Operating Hz High Speed Motor Volts 1 208 Volts Motor Amps 1 4.8 Amps RTU -1 Supply Outlet Summary Tested By: Luke Holmen Test Date: August 04, 2016 Motor Data RTU -1 /Supply Fan Outlet Type Motor Manufacturer Emerson Motor HP 0.9 HP Motor RPM 1075 RPM Motor Frame 48Y Motor Rated Volts 208 Volts Motor Phase 1 Motor Hertz 60 Hz Motor FL Amps 5.7 Amps Motor Service Factor 1.00 Sheave Data RTU -1 / Supply Fan 80 Drive Type Direct Drive Air Test Data Design GRD Total CFM 2000 CFM Actual GRD Total CFM 1710 CFM Return Air CFM Actual 1675 CFM Filter Data RTU -1 / Filter Bank 6 x 6 Filter Manufacturer Airguard Filter Type Pleated MERV Rating 8 Filter Quantity 2 Filter Size 20 x 25 x 1 Inches System / Unit Area Served Outlet Type Size LxW / D Design CFM Prelim Reading Final Reading % Final Outlet -01 Care Team 116 CD 12x 12 450 325 370 82 Outlet -02 Poct 117 CD 6 x 6 100 110 80 80 Outlet-03 IT 118 CD 10 x 10 250 225 235 94 Outlet -04 Storage 119 CD 6 x 6 100 35 90 90 Outlet -05 X -Ray 121 CD 8 x 8 200 160 160 80 Outlet -06 X -Ray 121 CD 8 x 8 200 175 160 80 Outlet -07 Staff 123 CD 8 x 8 150 195 125 83 Outlet -08 Hall 125 CD 8 x 8 175 180 155 89 Outlet -09 Soiled 122 CD 6 x 6 75 80 65 87 Outlet -10 Wellness Suite 115 CD 6 x 6 100 105 90 90 Outlet -11 Healing Suite 114 CD 6 x 6 100 100 90 90 Outlet -12 "> C�rrtmunity quite'113 CD 6 x 6 100 60 90 90 Totals: - - 2,000 1,760 1,710 86 Airtest Co Inc Preliminary TAB Report 2 of 7 AIRTEST Co., Inc. Roof Top Unit PROJECT: Urgent Care LOCATION: Tukwila, WA PROJECT M 16-3067-1 SYSTEM/UNIT: RTU -1 (Cont.) AREA: Staff 123 RTU -1 Return Inlet Summary DATE: 8/10/2016 CONTACT: Luke Holmen Tested By: Luke Holmen Test Date: August 04, 2016 System / Unit Area Served Outlet Type Size LxW / D Design CFM Prelim Reading Final Reading % Final Inlet -1 Hall 125 RG 24 x 24 RTU -1 / Outlet -03 1675 1675 Damper closed 100% RTU -1 / Outlet -03 Totals : - - - 1,676 1,676 0% * Notes RTU -1 4 -Aug -16 Luke Holmen Economizer did not seem to be operating RTU -1 4 -Aug -16 Luke Holmen Unit balanced in 100% return mode at 86% of design, motor is running on high speed. RTU -1 / Outlet -03 4 -Aug -16 Luke Holmen Damper closed 100% RTU -1 / Outlet -03 3 -Aug -16 Luke Holmen Read with a Velgrid Airtest Co Inc Preliminary TAB Report 3 of 7 Ca,AERTEST�r��o Roof Top Unit PROJECT: Urgent Care DATE: 8/10/2016 LOCATION: Tukwila, WA CONTACT: Luke Holmen PROJECT #: 16-3067-1 SYSTEM/UNIT: RTU -2 AREA: Lobby 101 Unit Data Unit Manufacturer Trane Unit Model Number YSC060A3RLA015U Unit Serial Number 647102724L _RTU -2 / Supply Fan 1075 RPM Fan Type / Class FC / 1 Test Data Actual Ext. SP Suction -0.46 in. we Actual Ext. SP Discharge 0.22 in. we Actual Total Ext. SP 0.68 in. we Fan SP In Actual -0.86 in. we Fan SP Out Actual 0.22 in. we Act. Tot. SP 1.08 in. we RTU -2 / Supply Fan Direct Drive Fan RPM Actual 966 RPM A. Tot. Inlet SP -0.87 in. wc. A. Tot. Discharge SP 0.22 in. wc. TSP Actual 1.09 in. wc. Electrical Test Data RTU -2 / Supply Fan Filter Manufacturer Final Operating Hz High Speed Motor Volts 1 207 Volts Motor Amps 1 4.7 Amps Airtest Co Inc Tested By: Luke Holmen Test Date: August 04, 2016 Motor Data RTU -2 / Supply Fan Motor Manufacturer Emerson Motor HP 0.9 HP Motor RPM 1075 RPM Motor Frame 48Y Motor Rated Volts 208 Volts Motor Phase 1 Motor Hertz 60 Hz Motor FL Amps 5.7 Amps Motor Service Factor 1.00 Sheave Data RTU -2 / Supply Fan Drive Type Direct Drive Air Test Data Design GRD Total CFM 2000 CFM Actual GRD Total CFM 1835 CFM Return Air CFM Actual 1500 CFM Filter Data RTU -2 / Filter Bank Filter Manufacturer Airguard Filter Type Pleated MERV Rating 8 Filter Quantity 2 Filter Size 20 x 25 x 2 Inches Preliminary TAB Report 4 of 7 I AIRTEST Co., Inc. rf��gg Roof Top Unit PROJECT: Urgent Care DATE: 8/10/2016 LOCATION: Tukwila, WA CONTACT: Luke Holmen PROJECT M 16-3067-1 SYSTEM/UNIT: RTU -2 (Cont.) AREA: Lobby 101 RTU -2 Supply Outlet Summary Tested By: Luke Holmen Test Date: August 04, 2016 System / Unit Area Served Outlet Type Size LxW / D Design CFM Prelim Reading Final Reading % Final Outlet -01 Family Suite 109 CD 8 x 8 125 105 120 96 Outlet -02 Technology Suite 110 CD 8 x 8 125 160 115 92 Outlet -03 Knowledge Suite 111 CD 8 x 8 125 145 120 96 Outlet -04 Hall 125 CD 6 x 6 85 100 80 94 Outlet -05 Kids Suite 112 CD 6 x 6 100 65 90 90 Outlet -06 Clean + Med 108 CD 6 x 6 100 90 90 90 Outlet -07 Hall 125 CD 6 x 6 100 75 90 90 Outlet -08 Lobby 101 CD 10 x 10 330 255 300 91 Outlet -09 Lobby 101 CD 10 x 10 330 250 300 91 Outlet -10 Hall 125 CD 10'x 10 330 280 300 91 Outlet -11 Scale 105 CD 6 x 6 50 105 45 90 Outlet -12 Check -Out + Copy Scan 106 CD 6 x 6 75 75 70 1 93 Outlet -13 Admin / Manager 107 CD 8 x 8 125 200 11592 Totals: - - 2,000 1,905 1,835 92% RTU -2 Return Inlet Summary System / Unit Area Served Outlet Type Size LxW / D Design CFM Prelim Reading Final Reading % Final Inlet -1 Hall 125 RG 24 x 24 1500 1500 Totals : - - - 1,600 1,600 0% * Notes RTU -2 4 -Aug -16 Luke Holmen Economizer did not seem to be operating RTU -2 3 -Aug -16 Luke Holmen Unit balanced in 100% return mode at 92% of design, motor is running on high speed. Airtest Co Inc Preliminary TAB Report 5 of 7 AIRTEST Co., Inc. q��g'g Fan Unit PROJECT: Urgent Care DATE: 8/10/2016 LOCATION: Tukwila, WA CONTACT: Luke Holmen PROJECT #: 16-3067-1 SYSTEMRJNIT: EFR-1 AREA: Restrooms EFR-1 Exhaust Inlet Summary Tested By: Luke Holmen Test Date: August 03, 2016 Motor Data Motor Manufacturer Greenheck Motor HP 1/10 HP Motor RPM 1750 RPM Motor Rated Volts 120 Volts Motor Phase 1 Motor Hertz 60 Hz Motor FL Amps 1.5 Amps Motor Service Factor 1.0 Sheave Data Drive Type Direct Drive Air Test Data Tot. GRD CFM Des. 150 CFM Tot. GRD CFM Act. 150 CFM System / Unit Unit Data Unit Location Roof Unit Serves Restrooms Unit Manufacturer Greenheck Model Number 6 -085 -V6 -X Serial Number 14629646 Fan Type / Class FC / 1 70 Test Data Fan RPM Actual 1018 RPM SP In Actual -0.006 in. we SP Out Actual 0.01 in. we External SP Actual 0.016 in. we Totals : Electrical Test Data Final Operating Hz 1018 RPM Motor Volts 1 120 Volts Motor Amps 1 0.2 Amps EFR-1 Exhaust Inlet Summary Tested By: Luke Holmen Test Date: August 03, 2016 Motor Data Motor Manufacturer Greenheck Motor HP 1/10 HP Motor RPM 1750 RPM Motor Rated Volts 120 Volts Motor Phase 1 Motor Hertz 60 Hz Motor FL Amps 1.5 Amps Motor Service Factor 1.0 Sheave Data Drive Type Direct Drive Air Test Data Tot. GRD CFM Des. 150 CFM Tot. GRD CFM Act. 150 CFM System / Unit Area Served Outlet Type Size LxW /D Design CFM Prelim Reading Final Reading % Final Inlet -1 Men's Toilet 104 EG 6 x 6 70 165 70 100 Inlet -2 Women's Toilet 103 EG 6 x 6 70 115 70 100 Totals : - - 140 280 140 1 100% * Notes Airtest rn /nr Preliminary TAB Report 6 of 7 AHRTEST Co., Enco P Fan Unit PROJECT: Urgent Care DATE: 8/10/2016 LOCATION: Tukwila, WA CONTACT: Luke Holmen PROJECT #: 16-3067-1 SYSTEM/UNIT: EFR-2 AREA: Janitor 124 EFR-2 Exhaust Inlet Summary Tested By: Luke Holmen Test Date: August 04, 2016 Motor Data Motor Manufacturer Greenheck Motor HP 1/10 HP Motor RPM 1750 RPM Motor Rated Volts 120 Volts Motor Phase 1 Motor Hertz 60 Hz Motor FL Amps 1.5 Amps Motor Service Factor 1.0 Sheave Data Drive Type Direct Drive Air Test Data Tot. GRD CFM Des. 220 CFM Tot. GRD CFM Act. 215 CFM System / Unit Unit Data Unit Location Roof Unit Serves Janitor Unit Manufacturer Greenheck Model Number 6 -085 -V6 -X Serial Number 14629645 Fan Type / Class FC / 1 100 100 Inlet -2 Test Data Fan RPM Actual 1367 RPM SP In Actual -0.005 in. we SP Out Actual 0.01 in. we External SP Actual 0.015 in. we Electrical Test Data Final Operating Hz 1367 RPM Motor Volts 1 120 Volts Motor Amps 1 0.5 Amps EFR-2 Exhaust Inlet Summary Tested By: Luke Holmen Test Date: August 04, 2016 Motor Data Motor Manufacturer Greenheck Motor HP 1/10 HP Motor RPM 1750 RPM Motor Rated Volts 120 Volts Motor Phase 1 Motor Hertz 60 Hz Motor FL Amps 1.5 Amps Motor Service Factor 1.0 Sheave Data Drive Type Direct Drive Air Test Data Tot. GRD CFM Des. 220 CFM Tot. GRD CFM Act. 215 CFM System / Unit Area Served Outlet Type Size LxW / D Design CFM Prelim Reading Final Reading % Final Inlet -1 Soiled 122 EG 6 RD 100 100 100 100 Inlet -2 Janitor 124 EG 6 RD 50 125 50 100 Inlet -3 Staff 123 EG I 6 RD 1 70 130 1 65 93 Totals : I - - 1 220 365 215 98% * Notes Airtest Co /nc Preliminary TAB Report 7 of 7 PERMIT COORD COPY PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: M16-0038 DATE: 03/09/16 PROJECT NAME: MULTICARE SITE ADDRESS: 17275 SOUTHCENTER PKWY - SUITE 160 X Original Plan Submittal Revision # before Permit Issued Response to Correction Letter # Revision # after Permit Issued DEPARTMENTS: Pri "& II AvA AR x-10-1 P Building Division Fire Prevention� Planning Division ❑ Public Works ❑ Structural ❑ Permit Coordinator PRELIMINARY REVIEW: DATE: 03/10/16 Not Applicable ❑ Structural Review Required ❑ (no approval/review required) REVIEWER'S INITIALS: 1J.iy:1 APPROVALS OR CORRECTIONS: DUE DATE: 04/07/16 Approved ❑ Approved with Conditions ❑ Corrections Required ❑ Denied ❑ (corrections entered in Reviews) (ie: Zoning Issues) Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: 12/16/2013 HERMANSON COMPANY LLP Home Espanol ' Contact. Safety & Health Claims & Insurance Washington State Department of Caber & Industries HERMANSON COMPANY LLP Owner or tradesperson 1221 2ND AVE N KENT, WA98032-2945 Principals 206-575-9700 NICOLAISEN, KNUT H, PARTNER/MEMBER KING County BROCK, DANIEL L, PARTNER/MEMBER FOX, DEAN M, PARTNER/MEMBER HENGEL, STEPHEN A, PARTNER/MEMBER DYCKMAN, KENNETH A, PARTNER/MEMBER ROBINETT, PAUL J, PARTNER/MEMBER HERMANSON, RICHARD L, PARTNER/MEMBER ALMON, KEVIN, PARTNER/MEMBER (End: 08/05/2010) MACDONALD, JAMES, PARTNER/MEMBER (End: 08/05/2010) Doing business as HERMANSON COMPANY LLP WA UBI No. Business type 602 004 844 Limited Liability Partnership Governing persons CORP HERMANSON LLC HERMANSON GROUP; License Page 1 of 3 A Workplace Rights Verify the contractor's active registration / license / certification (depending on trade) and any past violations. Construction Contractor Active. .............................. ..... _........................ Meets current requirements. https://secure.Ini.wa.gov/verify/Detail.aspx?UBI=602004844&LIC=HERMACL005BJ&SAW= 3/29/2016 MECHANICAL ABBREVIATIONS A AMPS IE INVERT ELEVATION AC AIR CONDITIONING IEER INTEGRATED ENERGY EFFICIENCY RATIO ACH AIR CHANGES PER HOUR IMC INTERNATIONAL MECHANICAL CODE ACT ACOUSTICAL CEILING TILE IN INCHES AD ACCESS DOOR IN WG INCHES WATER GAUGE ADD'L ADDITIONAL IPLV INTEGRATED PART LOAD VALUE AFF ABOVE FINISHED FLOOR KW KILOWATTS AFG ABOVE FINISHED GRADE LAT LEAVING AIR TEMPERATURE AHU AIR HANDLING UNIT LB/LBS POUND/POUNDS ALUM ALUMINUM LF/LIN FT LINEAL FOOT/FEET AMP/AMPS AMPERAGE LPG LIQUID PROPANE GAS AP ACCESS PANEL LPS LOW PRESSURE STEAM ARCH ARCHITECT LVG LEAVING BC BEADED COLLAR LWA SOUND POWER RATING LEVEL (IN Ds) BDD BACKDRAFT DAMPER LWG LOW WALL GRILLE BF BELOW FLOOR LWT LEAVING WATER TEMPERATURE BHP BRAKE HORSEPOWER MAX MAXIMUM BLDG BUILDING MAU MAKE UP AIR UNIT BOD BOTTOM OF DUCT MBH 1000 BRITISH THERMAL UNITS/HOUR BOP BOTTOM OF PIPE MCA MINIMUM CIRCUIT AMPACITY BOT BOTTOM MD MOTORIZED DAMPER BS BIRD SCREEN / BLACK STEEL MFR MANUFACTURER BTU BRITISH THERMAL UNIT MISC MISCELLANEOUS BTUH BRITISH THERMAL UNITS PER HOUR MIN MINIMUM/MINUTE CAP CAPACITY MPS MEDIUM PRESSURE STEAM CC CONTROLS CONTRACTOR MT MOUNT CD CEILING DIFFUSER/CONDENSATE DRAIN MTD MOUNTED CDWR CONDENSER WATER RETURN MUW MAKE-UP WATER CDWS CONDENSER WATER SUPPLY NA NOT APPLICABLE CFM CUBIC FEET PER MINUTE NC NORMALLY CLOSED/NOISE CRITERIA CHWR CHILLED WATER RETURN NG/NGAS NATURAL GAS CHWS CHILLED WATER SUPPLY NIC NOT IN CONTRACT CLG CEILING NO NORMALLY OPEN/NUMBER COL COLUMN NPW NON -POTABLE WATER CONC CONCRETE N -R NON-RESIDENTIAL COND CONDENSATE OA/OSA OUTSIDE AIR CONN CONNECT/CONNECTED/CONNECTION OBD OPPOSED BLADE DAMPER CONT CONTINUOUS/CONTINUATION OD OUTSIDE DIAMETER/DIMENSION CONTR CONTRACTOR PCF POUNDS PER CUBIC FOOT COORD COORDINATE PD PRESSURE DROP COP COEFFICIENT OF PERFORMANCE PH PHASE CT COOLING TOWER POC POINT OF CONNECTION CU CUBIC/CONDENSER UNIT P/PRESS PRESSURE CW DOMESTIC COLD WATER/CONDENSER WATER PSI POUNDS PER SQUARE INCH DB DUCTBOARD/DRY BULB/DECIBEL PSIG POUNDS PER SQUARE INCH GAUGE DDC DIRECT DIGITAL CONTROL QTY QUANITY DEFL DEFLECTION R RETURN GRILLE/RELOCATED/RETURN DEG DEGREE/DEGREES RA RETURN AIR DIA DIAMETER RD/RND ROUND DMPR DAMPER REF REFERENCE DN DOWN REQ REQUIRED DWG DRAWING RESID RESIDENTIAL EXH EXHAUST RF RELIEF EA EACH RG REFRIGERANT DISCHARGE GAS EAT ENTERING AIR TEMPERATURE RL REFRIGERANT LIQUID EC EGGCRATE GRILLE/END CAP/ELEC CONTRACTOR RPM REVOLUTIONS PER MINUTE EER ENERGY EFFICIENT RATING RS REFRIGERANT SUCTION EF EXHAUST FAN S SUPPLY EFF EFFICIENCY SA SUPPLY AIR EL ELEVATION SAT SATURATION/SUPPLY AIR TEMPERATURE ELEC/ELECT ELECTRICAL/ELECTRIC SD SMOKE DETECTOR EMCS ENERGY MANAGEMENT CONTROL SYSTEM S/D SLIP & DRIVE CONNECTION ENT ENTERING S -C SEATTLE CODE EQUIP EQUIPMENT SEER SEASONAL ENERGY EFFICIENCY RATING ESP EXTERNAL STATIC PRESSURE SENS SENSIBLE EWT ENTERING WATER TEMPERATURE SL SOUND LINED EXIST EXISTING SM SHEETMETAL EXH EXHAUST SPEC SPECIFICATION F FAHRENHEIT SO SCREENED OPENING FAC FIRE ALARM CONTRACTOR SOG SLAB ON GRADE FD FIRE DAMPER SP STATIC PRESSURE FDC FIRE DEPARTMENT CONNECTION SF SQUARE FEET FF FINISHED FLOOR SS STAINLESS STEEL FIC FURNISHED AND INSTALLED BY CONTRACTOR STRUC STRUCTURAL FIO FURNISHED AND INSTALLED BY OWNER TA TRANSFER AIR FLA FULL LOAD AMPS TEMP TEMPERATURE/TEMPORARY FLEX FLEXIBLE TBD TO BE DETERMINED FLR FLOOR TOD TOP OF DUCT FOB FLAT ON BOTTOM TOS TOP OF STEEL/TOP OF SLAB FOIC FURNISHED BY OTHERS, TOT TOTAL INSTALLED BY CONTRACTOR TSP TOTAL STATIC PRESSURE FOS FLAT ON SIDE TSTAT THERMOSTAT FOT FLAT ON TOP TYP TYPICAL FP FIRE PROTECTION UH UNIT HEATER FPM FEET PER MINUTE UNO UNLESS NOTED OTHERWISE FSD FIRE/SMOKE DAMPER V VOLT FT FOOT/FEET VD VOLUME DAMPER FUT FUTURE VEL VELOCITY FV FACE VELOCITY VERT VERTICAL G GRILLE VFD VARIABLE FREQUENCY DRIVE GA GAUGE/GALLON VOL VOLUME GALV GALVANIZED W WRAPPED DUCT GC GENERAL CONTRACTOR WB WET BULB GPM GALLONS PER MINUTE WG WATER GAUGE GRD GRILLE/REGISTER/DIFFUSER W/ WITH GWB GYPSUM WALL BOARD W/0 WITHOUT HD HEAD W/SF WATTS PER SQUARE FOOT HORIZ HORIZONTAL WSEC WASHINGTON STATE ENERGY CODE HP HORSEPOWER HR HOUR HSPF HEATING SEASONAL PERFORMANCE FACTOR HT HEIGHT HWTG HIGH WALL TRANSFER GRILLE HWR HOT WATER RETURN HWS HOT WATER SUPPLY HX HEAT EXCHANGER HZ HERTZ IBC INTERNATIONAL BUILDING CODE ICW INDUSTRIAL COLD WATER ID INSIDE DIAMETER/DIMENSION MECHANICAL LEGEND 10X10 RECT SUWRLY AIR DUCT ,10X10 � UP/TOWARD 10X10 RECT SUWRLY AIR DUCT 10X�-Q DN/AWAY 10X10 RECT EXHIAUST OR RETURN DUCT t' 0X10 � UP/TOWARD 10X10 ,' RECT EXHAUST OR RETURN DUCT ,10X� DN/AWAY 100 100 rn, ROUND DIUCT - UP/TOWARD � 1����� �( ROUND DIUCT - DN/ AWAY "-l�J 12X100 FLATOVAL DUCT - UP/ TOWARD 12X100;, FIATOVAL DUCT - DN/ AWAY TOO: DUCT OVERLAP 100 BOOT TAP' 100 100 45 TAP 100 VOLUME [DAMPER 100 RISE(R) 8dc DROP(D) TRANSITION TURNING 'VANES/SPLITTERS t vs) } DUCT M01UP1TED SMOKE DETECTOR "D� BACK DW4FfT DAMPER FLEXIBLE DUCT � NR FLOWS (FORCED AIR) COIMBINATION FSD FIRIE DAMPER SMIOKE DAMPER MO)TOR OPERATED DAMPER ACCESS DOORS SOIUND TRAP FLEX CONNECTION 16X16SL ACOUSTICALLY LINED DUCT (SL) FABRIC DWCT CLEARANCE ® SUPPLY AIR DIFFUSER (WITH CODE BLANKOFF) CEILING RETURN, TRANSFER OR EXHAUST FAIR GRILLE SLOTTED 1DFFFUSER (PLAN VIEW) Q REVISION (CLOUD & TRIANGLE ##0 ROUND DWCT SYMBOL ##X## DEGREES TREES SYMBOL SiYM OL ® POINT OF CONNECTION CD1-100 GRD TAG IDENTIFIER = TYPE -CFM 80 SIZE T T'STAT/TEMP SENSOR ; o CARBON DIOXIDE H HUMIDITY SENSOR SENSOR sD SMOKE DETECTOR ; co CARBON MONOXIDE sP STATIC PRESSURE SENSOR SENSOR EXISTING DIUCTWORK MECHANICAL GENERAL NOTES 1. WORK SHALL CONFORM TO APPLICABLE CODES AND REGULATIONS, INCLUDING, BUT NOT LIMITED TO THE 2012 IBC, 2012 WSEC, & 2)12 IMC. 2. DIMENSIONS ARE TO FACE OF STUD, CONCRETE, OR MASONRY UNLESS NOTED OTHERWISE. 3. DO NOT SCALE DRAWINGS. DIMENSIONS GOVERN. 4. VERIFY EXISTING CONDITIONS, DIMENSIONS, DETAILS, ETC. NOTIFY ENGINEER OF ANY DISCREPANCIES PRIOR TO PROCEEDING WITH WORC 5. WHEN CONSTRUCTION DETAILS ARE NOT SHOWN OR NOTED FOR ANY PART OF THE WORK, DETAILS SHALL BE THE SAME AS FOR OTHER SIMILAR WORK. IF ADDITIONAL QUESTIONS REMAIN, CONTACT THE ENGINEER PRIOR TO PROCEEDING. 6. ALL STRUCTURAL OPENINGS AND PLATFORMS SHALL BE PROVIDED BY THE GENERAL CONTRACTOR UNLESS NOTED OTHERWISE. 7. DUCT SEALING AND CONSTRUCTION TO MEET SMACNA AND ENERGY CODE REQUIREMENTS. UNLESS OTHERWISE NOTED, LOW PRESSURE DUCTWORK (DOWNSTREAM OF VAV BOXES, CONSTANT VOLUME AC SYSTEMS, TOILET EXHAUSTS, ETC. TO MEET 2" CONSTRUCTION STANDARDS WITH SEAL CLASS C. MEDIUM PRESSURE DUCTWORK (UPSTREAM OF VAV BOXES, HIGH VELOCITY EXHAUSTS, ETC.) TO MEET 4" CONSTRUCTION STANDARDS WITH SEAL CLASS A. DUCT RISERS IN SHAFTS WITH DAMPERED PENETRATIONS TO MEET 6" CONSTRUCTION STANDARDS WITH SEAL CLkSS A. 8. ALL CEILING DIFFUSERS ARE 4 -WAY THROW UNLESS NOTED OTHERWISE. 9. ALL DUCT DIMENSIONS ARE CLEAR INSIDE DIMENSIONS AFTER LINING HAS BEEN ACCOUNTED FOR. 10. OUTSIDE AIR INTAKES ON ALL AIR HANDLING UNITS SHALL BE 10 FEET AWAY FROM ANY FUEL BURNING EQUIPMENT OR 3 FEET BELOV ANY PLUMBING VENT OR EXHAUST OUTLET WITHIN 10 FEET 11. ALL AIR ECONOMIZERS SHALL BE CAPABLE OF THE FOLLOWING: -0% TO 100% OF THE DESIGN SUPPLY AIR -CONTROLLED BY A CONTROL SYSTEM DETERMINING IF THE OUTSIDE AIR CAN MEET PART OR ALL OF THE BUILDING COOLING LOADS. -INTEGRATED TO PROVIDE PARTIAL COOLING EVEN WHEN MECHANICAL COOLING IS REQUIRED. 12. OUTSIDE AIR INTAKE,RELIEF, AND EXHAUST OPENINGS SHALL BE EQUIPPED WITH MOTORIZED (OR GRAVITY DAMPERS PER EXCEPTIONS IN C403.2.4.4) WHICH CLOSE AUTOMATICALLY WHEN SYSTEM IS OFF OR UPON POWER FAILURE. 13. THE CONTROL SYSTEM SHALL BE 7 -DAY PROGRAMMABLE, CAPABLE OF BEING SET FOR SEVEN (7) DIFFERENT DAY TYPES PER WEEK, AND CAPABLE OF A DEADBAND SETTING OF AT LEAST 56F (10'F FOR RESIDENTIAL BETWEEN THE HEATING AND COOLING SETPOINTS. MU CONTROL SYSTEM SHALL INCLUDE A MICROPROCESSOR AND BE CAPABLE OF RESETTING SU PLY AIR TEMPERATURES BY REPRESENTATIVE BUILDMG LOADS. 14. RECORD DRAWINGS OF THE ACTUAL INSTALLATION SHALL BE PROVIDED TO THE BUILDING OWNER WITHIN 90 DAYS OF THE DATE OF SYSTEM ACCEPTANCE PER THE WASHINGTON STATE ENERGY CODE. AN OPERATING MANUAL AND MAINTENANCE MANUAL SHALL BE PROVIDED TO THE BUILDING OWNER. ALL HVAC SYSTEMS SHALL BE BALANCED AND A WRITTEN BALANCING REPORT SHALL BE PROVIDED TO THE OWNER. HVAC CONTROL SYSTEMS SHALL BE TESTED TO ENSURE THAT THEY OPERATE IN ACCORDANCE WITH APPROVED PLANS. A PRELIMINARY COMMISSIONING REPORT OF TEST PROCEDURES AND RESULTS SHALL BE PREPARED PRIOR TO ISSUANCE OF A FINAL CERTIFICATE OF OCCUPANCY. A COMPLETE FINAL COMMISSIONING REPORT OF TEST PROCEDURES AND RESULTS SHALL BE PROVIDED TO THE OWNER. COMMISSIONING, SYSTEM BALANCING, RECORD DRAWINGS AS REQUIRED PER THE WASHINGTON STATE ENERGY CODE C408. 15. MECHANICAL SYSTEMS SHALL COMPLY WITH SEISMIC RESTRAINT REQUIREMENTS OF THE BUILDING CODE SMACNA AND ASCE 7. ALL LIFE SAFETY OR HAZARDOUS MATERIAL RELATED SYSTEMS SHALL BE DEEMED AN Ip=1.5 FOR RESTRAINT MErfHODS OR AS NOTED ON THE DRAWINGS.. REFER TO CODES FOR INSTALLATION REQUIREMENTS AND EXCEPTIONS BASED ON SIZING, WEIGHTS AND MOUNTING HEIGHTS. 16. PROVIDE EARTHQUAKE RESTRAINTS FOR HVAC EQUIPMENT AS REQUIRED BY SMACNA SEISMIC RESTRAINT MANUAL, SEISMIC HAZARD B. WIRES FOR CEILING SYSTEM ETC. SHALL NOT BE HUNG OFF HVAC EQUIPMENT OR HVAC EQUIPMENT SUPPORTS. 17. PROVIDE FIRE AND COMBINATION FIRE/SMOKE DAMPERS WHERE SHOWN ON PLANS AND WHERE REQUIRED PER CODE. 18. ALL PIPING PENETRATIONS THROUGH RATED ASSEMBLIES SHALL BE SEALED WITH AN UL APPROVED FIRE CAULKING. 19. SMOKE DETECTORS PROVIDING AUTOMATIC SHUTDOWN SHALL BE PROVIDED FOR HVAC EQUIPMENT DELIVERING IN EXCESS OF 2000 CFM [INCLUDING MULTIPLE UNITS DUCTED INTO COMMON DISTRIBUTION OR RETURN, WITH AN AGGREGATE SUPPLY GREATER THAN 2000 CFM] OR EACH STORY OF RETURN SYSTEMS OVER 15,000 CFM IN A MULTI -STORY INSTALLATION, PER CODE. SMOKE DETECTORS SHALL BE FIC (ELEC) LINO. POWER -WIRING AND INTERLOCK TO FIRE ALARM SYSTEM BY ELECTRICAL CONTRACTOR AS APPLICABLE. 20. MECHANICAL ACCESS PANELS SHALL BE PROVIDED BY MECHANICAL CONTRACTOR AND INSTALLED BY GENERAL CONTRACTOR. 21. ALL MOTOR STARTERS NOT SHOWN IN EQUIPMENT SCHEDULES SHALL BE FURNISHED AND INSTALLED BY ELECTRICAL CONTRACTOR. MOTOR EFFICIENCIES TO MEET OR EXCEED CODE MINIMUM. 22. FOR ALL "SEALED AIR TIGHT" SHAFTS OR ROOMS, THE FOLLOWING SHALL OCCUR: -ALL VERTICAL JOINTS & CORNERS INSIDE THE SHAFT SHALL BE PROVIDED WITH A CONTINUOUS SEAL FOR THE LENGTH OF THE JOINT (BY GC). -TOP AND BOTTOM WALL TRACKS SHOULD BE CAULKED ALONG THEIR ENTIRE LENGTH (BY GC). -ANY FLOOR DECKING PERPENDICULAR TO THE SHAFT SHALL BE CAULKED (BY GC). )FILLING WITH ROCK WOOL IS NOT ACCEPTABLE -USE SECTIONPENETRATIONS T909.50OFTTHE52012 IBC FOR CMAX ALDOWABLLEKLEAKAGE I AREA, FO'LLOWINGATHEBGUIDELINES FOROTIGHTIDST IR SHAFT COISTRUCTION. -ALL DOORS SHALL BE PROVIDED WITH TIGHT FITTING GASKETS, AND OPEN AGAINST THE DIRECTION OF ROOM/SHAFT PRESSURE. 23. MAXIMUM LENGTH OF FLEXIBLE DUCT SHALL BE 12 FEET. REFER TO INSTALLATION DETAILS FOR SUPPORT REQUIREMENTS. FLEXIBLE DUCT FLAME SPREAD RATING SHALL BE < 25 AND SMOKE DEVELOPED RATING SHALL BE < 50. USE FLEXIDUCT MODEL G -KM FOR LOW AND MEDIUM PRESSURE APPLICATIONS OR APPROVED EQUAL. 24. LOCATION AND DETAILS OF EQUIPMENT DUCT ROUTING, AND CONNECTIONS ARE APPROXIMATE. COORDINATE FINAL LOCATIONS WITH OTHER TRADES. INSTALL IN ACCORDANCE WITH APPROVED SUBMITTALS AND DETAIL DRAWINGS WHEN APPLICABLE. 25. FOR RESIDENTIAL INSULATION ON DUCTWORK AND PIPING SEE ENERGY CODE CHAPTER R403. 26. ELECTRICAL METERING OF SYSTEMS AS REQUIRED BY ENERGY CODE SECTION C409 IS BY ELECTRICAL. THE ELECTRICAL DESIGN & CONTRACTOR TEAM WILL FURNISH THE NECESSARY ELECTRICAL DISTRIBUTION AND METERING COMPONENTS - SEE ELECTRICAL DRAWINGS. THE MECHANICAL CONTRACTOR WILL FURNISH A BUILDING MANAGEMENT SYSTEM CAPABLE OF COLLECTING AND STORING THE INFORMATION. A PERMANENT AND VISIBLE DISPLAY IS TO BE PROVIDED FOR EACH BUILDING, READILY ACCESSIBLE TO OPERATION AND MANAGEMENT PERSONNEL DEMO DUCTfWORK LAST UPDATED WALL-MOUINTED GRILLE oo PIPE ELBOIW UP INSULATION R -VALUE PIPE ELBOW DN SUPPLY & RETURN DIRECTION OF FLOW R-8 DIRECTION OF SLOPE DOWN OUTSIDE AIR WITHIN CONDITIONED SPACE, INSIDE BUILDING PLUG OR (CAP --®--� PRESS REO)WCING ASSEMBLY ���----i SOLENOID 'VALVE 1,2 PUMP �-CHWS /CHWR-s CHILLED WIATER SUPPLY/RETURN �- RL/RS---s REFRIGERANT LIQUID/SUCTION �- NG --s NATURAL GAS z - LPG -s LIQUID PROPANE GAS Z--CDWS /CDWR-s CONDENSER WATER SUPPLY/RETURN HWS/HWR-s HEATING WATER SUPPLY/RETURN Z--- COND -4 CONDENSATiE r- FOV -s FUEL OIL (VENT Z-- FOS / FOR -s FUEL OIL :SUPPLY/RETURN 2-- RDG -5 REFRIGERANT DISCHARGE GAS MECHANICAL GENERAL NOTES 1. WORK SHALL CONFORM TO APPLICABLE CODES AND REGULATIONS, INCLUDING, BUT NOT LIMITED TO THE 2012 IBC, 2012 WSEC, & 2)12 IMC. 2. DIMENSIONS ARE TO FACE OF STUD, CONCRETE, OR MASONRY UNLESS NOTED OTHERWISE. 3. DO NOT SCALE DRAWINGS. DIMENSIONS GOVERN. 4. VERIFY EXISTING CONDITIONS, DIMENSIONS, DETAILS, ETC. NOTIFY ENGINEER OF ANY DISCREPANCIES PRIOR TO PROCEEDING WITH WORC 5. WHEN CONSTRUCTION DETAILS ARE NOT SHOWN OR NOTED FOR ANY PART OF THE WORK, DETAILS SHALL BE THE SAME AS FOR OTHER SIMILAR WORK. IF ADDITIONAL QUESTIONS REMAIN, CONTACT THE ENGINEER PRIOR TO PROCEEDING. 6. ALL STRUCTURAL OPENINGS AND PLATFORMS SHALL BE PROVIDED BY THE GENERAL CONTRACTOR UNLESS NOTED OTHERWISE. 7. DUCT SEALING AND CONSTRUCTION TO MEET SMACNA AND ENERGY CODE REQUIREMENTS. UNLESS OTHERWISE NOTED, LOW PRESSURE DUCTWORK (DOWNSTREAM OF VAV BOXES, CONSTANT VOLUME AC SYSTEMS, TOILET EXHAUSTS, ETC. TO MEET 2" CONSTRUCTION STANDARDS WITH SEAL CLASS C. MEDIUM PRESSURE DUCTWORK (UPSTREAM OF VAV BOXES, HIGH VELOCITY EXHAUSTS, ETC.) TO MEET 4" CONSTRUCTION STANDARDS WITH SEAL CLASS A. DUCT RISERS IN SHAFTS WITH DAMPERED PENETRATIONS TO MEET 6" CONSTRUCTION STANDARDS WITH SEAL CLkSS A. 8. ALL CEILING DIFFUSERS ARE 4 -WAY THROW UNLESS NOTED OTHERWISE. 9. ALL DUCT DIMENSIONS ARE CLEAR INSIDE DIMENSIONS AFTER LINING HAS BEEN ACCOUNTED FOR. 10. OUTSIDE AIR INTAKES ON ALL AIR HANDLING UNITS SHALL BE 10 FEET AWAY FROM ANY FUEL BURNING EQUIPMENT OR 3 FEET BELOV ANY PLUMBING VENT OR EXHAUST OUTLET WITHIN 10 FEET 11. ALL AIR ECONOMIZERS SHALL BE CAPABLE OF THE FOLLOWING: -0% TO 100% OF THE DESIGN SUPPLY AIR -CONTROLLED BY A CONTROL SYSTEM DETERMINING IF THE OUTSIDE AIR CAN MEET PART OR ALL OF THE BUILDING COOLING LOADS. -INTEGRATED TO PROVIDE PARTIAL COOLING EVEN WHEN MECHANICAL COOLING IS REQUIRED. 12. OUTSIDE AIR INTAKE,RELIEF, AND EXHAUST OPENINGS SHALL BE EQUIPPED WITH MOTORIZED (OR GRAVITY DAMPERS PER EXCEPTIONS IN C403.2.4.4) WHICH CLOSE AUTOMATICALLY WHEN SYSTEM IS OFF OR UPON POWER FAILURE. 13. THE CONTROL SYSTEM SHALL BE 7 -DAY PROGRAMMABLE, CAPABLE OF BEING SET FOR SEVEN (7) DIFFERENT DAY TYPES PER WEEK, AND CAPABLE OF A DEADBAND SETTING OF AT LEAST 56F (10'F FOR RESIDENTIAL BETWEEN THE HEATING AND COOLING SETPOINTS. MU CONTROL SYSTEM SHALL INCLUDE A MICROPROCESSOR AND BE CAPABLE OF RESETTING SU PLY AIR TEMPERATURES BY REPRESENTATIVE BUILDMG LOADS. 14. RECORD DRAWINGS OF THE ACTUAL INSTALLATION SHALL BE PROVIDED TO THE BUILDING OWNER WITHIN 90 DAYS OF THE DATE OF SYSTEM ACCEPTANCE PER THE WASHINGTON STATE ENERGY CODE. AN OPERATING MANUAL AND MAINTENANCE MANUAL SHALL BE PROVIDED TO THE BUILDING OWNER. ALL HVAC SYSTEMS SHALL BE BALANCED AND A WRITTEN BALANCING REPORT SHALL BE PROVIDED TO THE OWNER. HVAC CONTROL SYSTEMS SHALL BE TESTED TO ENSURE THAT THEY OPERATE IN ACCORDANCE WITH APPROVED PLANS. A PRELIMINARY COMMISSIONING REPORT OF TEST PROCEDURES AND RESULTS SHALL BE PREPARED PRIOR TO ISSUANCE OF A FINAL CERTIFICATE OF OCCUPANCY. A COMPLETE FINAL COMMISSIONING REPORT OF TEST PROCEDURES AND RESULTS SHALL BE PROVIDED TO THE OWNER. COMMISSIONING, SYSTEM BALANCING, RECORD DRAWINGS AS REQUIRED PER THE WASHINGTON STATE ENERGY CODE C408. 15. MECHANICAL SYSTEMS SHALL COMPLY WITH SEISMIC RESTRAINT REQUIREMENTS OF THE BUILDING CODE SMACNA AND ASCE 7. ALL LIFE SAFETY OR HAZARDOUS MATERIAL RELATED SYSTEMS SHALL BE DEEMED AN Ip=1.5 FOR RESTRAINT MErfHODS OR AS NOTED ON THE DRAWINGS.. REFER TO CODES FOR INSTALLATION REQUIREMENTS AND EXCEPTIONS BASED ON SIZING, WEIGHTS AND MOUNTING HEIGHTS. 16. PROVIDE EARTHQUAKE RESTRAINTS FOR HVAC EQUIPMENT AS REQUIRED BY SMACNA SEISMIC RESTRAINT MANUAL, SEISMIC HAZARD B. WIRES FOR CEILING SYSTEM ETC. SHALL NOT BE HUNG OFF HVAC EQUIPMENT OR HVAC EQUIPMENT SUPPORTS. 17. PROVIDE FIRE AND COMBINATION FIRE/SMOKE DAMPERS WHERE SHOWN ON PLANS AND WHERE REQUIRED PER CODE. 18. ALL PIPING PENETRATIONS THROUGH RATED ASSEMBLIES SHALL BE SEALED WITH AN UL APPROVED FIRE CAULKING. 19. SMOKE DETECTORS PROVIDING AUTOMATIC SHUTDOWN SHALL BE PROVIDED FOR HVAC EQUIPMENT DELIVERING IN EXCESS OF 2000 CFM [INCLUDING MULTIPLE UNITS DUCTED INTO COMMON DISTRIBUTION OR RETURN, WITH AN AGGREGATE SUPPLY GREATER THAN 2000 CFM] OR EACH STORY OF RETURN SYSTEMS OVER 15,000 CFM IN A MULTI -STORY INSTALLATION, PER CODE. SMOKE DETECTORS SHALL BE FIC (ELEC) LINO. POWER -WIRING AND INTERLOCK TO FIRE ALARM SYSTEM BY ELECTRICAL CONTRACTOR AS APPLICABLE. 20. MECHANICAL ACCESS PANELS SHALL BE PROVIDED BY MECHANICAL CONTRACTOR AND INSTALLED BY GENERAL CONTRACTOR. 21. ALL MOTOR STARTERS NOT SHOWN IN EQUIPMENT SCHEDULES SHALL BE FURNISHED AND INSTALLED BY ELECTRICAL CONTRACTOR. MOTOR EFFICIENCIES TO MEET OR EXCEED CODE MINIMUM. 22. FOR ALL "SEALED AIR TIGHT" SHAFTS OR ROOMS, THE FOLLOWING SHALL OCCUR: -ALL VERTICAL JOINTS & CORNERS INSIDE THE SHAFT SHALL BE PROVIDED WITH A CONTINUOUS SEAL FOR THE LENGTH OF THE JOINT (BY GC). -TOP AND BOTTOM WALL TRACKS SHOULD BE CAULKED ALONG THEIR ENTIRE LENGTH (BY GC). -ANY FLOOR DECKING PERPENDICULAR TO THE SHAFT SHALL BE CAULKED (BY GC). )FILLING WITH ROCK WOOL IS NOT ACCEPTABLE -USE SECTIONPENETRATIONS T909.50OFTTHE52012 IBC FOR CMAX ALDOWABLLEKLEAKAGE I AREA, FO'LLOWINGATHEBGUIDELINES FOROTIGHTIDST IR SHAFT COISTRUCTION. -ALL DOORS SHALL BE PROVIDED WITH TIGHT FITTING GASKETS, AND OPEN AGAINST THE DIRECTION OF ROOM/SHAFT PRESSURE. 23. MAXIMUM LENGTH OF FLEXIBLE DUCT SHALL BE 12 FEET. REFER TO INSTALLATION DETAILS FOR SUPPORT REQUIREMENTS. FLEXIBLE DUCT FLAME SPREAD RATING SHALL BE < 25 AND SMOKE DEVELOPED RATING SHALL BE < 50. USE FLEXIDUCT MODEL G -KM FOR LOW AND MEDIUM PRESSURE APPLICATIONS OR APPROVED EQUAL. 24. LOCATION AND DETAILS OF EQUIPMENT DUCT ROUTING, AND CONNECTIONS ARE APPROXIMATE. COORDINATE FINAL LOCATIONS WITH OTHER TRADES. INSTALL IN ACCORDANCE WITH APPROVED SUBMITTALS AND DETAIL DRAWINGS WHEN APPLICABLE. 25. FOR RESIDENTIAL INSULATION ON DUCTWORK AND PIPING SEE ENERGY CODE CHAPTER R403. 26. ELECTRICAL METERING OF SYSTEMS AS REQUIRED BY ENERGY CODE SECTION C409 IS BY ELECTRICAL. THE ELECTRICAL DESIGN & CONTRACTOR TEAM WILL FURNISH THE NECESSARY ELECTRICAL DISTRIBUTION AND METERING COMPONENTS - SEE ELECTRICAL DRAWINGS. THE MECHANICAL CONTRACTOR WILL FURNISH A BUILDING MANAGEMENT SYSTEM CAPABLE OF COLLECTING AND STORING THE INFORMATION. A PERMANENT AND VISIBLE DISPLAY IS TO BE PROVIDED FOR EACH BUILDING, READILY ACCESSIBLE TO OPERATION AND MANAGEMENT PERSONNEL 1 REFER TO ENERGY CODE SECTION C403.2.7 FOR FURTHER REQUIREMENTS 2 INSULATED COOLED DUCTS REQUIRED A VAPOR RETARDER (PERM < 0.5) AND SEALED JOINTS 3 WEATHERPROOF BARRIER REQUIRED AROUND DUCTWORK TO MAINTAIN WATER TIGHTNESS 4 INSULATE OUTSIDE AIR DUCTS TO BUILDING EXTERIOR WALL LEVEL PER ENERGY CODE SECTION: C403.2.7.1 UNTIL CONNECTED TO EQUIPMENT SERVED OR TO THE CODE REQUIRED SHUTOFF DAMPER (THEN R-6 FOR REST OF INSTALLATION) OR HEATING & COOLING EQUIPMENT 5 R-7 CAN BE USED IN LIEU OF BUILDING ENVELOPE INSULATION LEVEL IF: DEDICATED OUTSIDE AIR SYSTEM AND LESS THAN 2,800 CFM SUPPLY AIR RECEIVED CITY OF TUKWILA MAR 0 8 2016 PERMIT CENTER MINIMUMI INSULATION LAST UPDATED: 01/10/14 MINIMUM INSULATION LAST UPDATED 01/10/14 DUCT TYPE DUCT LOCATION IN HEATED AND MECHANICALLY COOLED DUCT SYSTEM INSULATION R -VALUE REMARKS SUPPLY & RETURN NOT WITHIN CONDITIONED SPACE, OUTSIDE BUILDING R-8 1,2,3 OUTSIDE AIR WITHIN CONDITIONED SPACE, INSIDE BUILDING SEE NOTES 4 & 5 1,2,3,4,5 SUPPLY & RETURN NOT WITHIN CONDITIONED SPACE: INSIDE BUILDING R-6 1,2 SUPPLY AIR <550 OR >1050 WITHIN CONDITIONED SPACE t R-3.3 1,2 1 REFER TO ENERGY CODE SECTION C403.2.7 FOR FURTHER REQUIREMENTS 2 INSULATED COOLED DUCTS REQUIRED A VAPOR RETARDER (PERM < 0.5) AND SEALED JOINTS 3 WEATHERPROOF BARRIER REQUIRED AROUND DUCTWORK TO MAINTAIN WATER TIGHTNESS 4 INSULATE OUTSIDE AIR DUCTS TO BUILDING EXTERIOR WALL LEVEL PER ENERGY CODE SECTION: C403.2.7.1 UNTIL CONNECTED TO EQUIPMENT SERVED OR TO THE CODE REQUIRED SHUTOFF DAMPER (THEN R-6 FOR REST OF INSTALLATION) OR HEATING & COOLING EQUIPMENT 5 R-7 CAN BE USED IN LIEU OF BUILDING ENVELOPE INSULATION LEVEL IF: DEDICATED OUTSIDE AIR SYSTEM AND LESS THAN 2,800 CFM SUPPLY AIR RECEIVED CITY OF TUKWILA MAR 0 8 2016 PERMIT CENTER MINIMUMI INSULATION LAST UPDATED: 01/10/14 FLUID DESIGN INSULATION CONDUCTIVITY NOMINAL PIPE DIAMETER (INCH) OPERATING TEMP °F CONDUCTIVITY RANGE MEAN TEMP RATING °F <1 1 TO <1-1/2 1-1/2 TO <4 4 TO <8 >8 HEATING SYSTEMS (STEAM, CONDENSATE, HYDRONIC HOT WATER, DOMESTIC HOT WATER) >350 0.32-0.34 250 4.5 5.0 5.0 5.0 5.0 251-350 0.29-0.32 200 3.0 4.0 4.5 4.5 4.5 201-250 0.27-0.30 150 2.5 2.5 2.5 3.0 3.0 141-200 0.25-0.29 125 1.5 1.5 2.0 2.0 2.0 105-140 0.21-0.28 100 1.0 1.0 1.5 1.5 1.5 DOMESTIC COLD WATER AND HORIZONTAL RAIN LEADERS TO FIRST VERTICAL RAIN LEADER 40-60 1 0.21-0.27 75 1 as 7 0.5 1 1.0 1.0 1.0 COOLING SYSTEMS (CHILLED WATER, BRINE AND REFRIGERANT, WATERSIDE ECONOMIZER SYSTEMS)** 40-60 0.21-0.27 75 0.5 1 0.5 1.0 1.0 1.0 <40 0.20-0.26 75 1 0.5 1 1.0 1 1.0 1.0 1.5 NOT REQUIRED FOR STRAINERS, CONTROL VALVES & BALANCING VALVES ASSOCIATED WITH PIPING 1" OR LESS IN DIA. ** TYPICAL CONDENSER WATER PIPE IN NON -ECONOMIZER SYSTEMS DOES NOT REQUIRE INSULATION REVISIONS No than, ^ 5h?Il he, rn.,7do to the scope 0 �^1orl< withct.,t prior e ;proval of Tukwila Building Division. NOTE: Revisions will require n newi p!�:n submittal and may include additional p!c.n reviavr fees. APN NUMBER 2623049063 LEGAL DESCRIPTION LOT 1 OF CITY OF TUKWILA SHORT PLAT NO 80 -45 -SS RECORDING NO 8106040707 SD PLAT DAF - POR NE 1/4 OF SW 1/4 LY WLY OF SOUTHCENTER PARKWAY & LY ELY OF INTERSTATE HWY 5 - COMM NE COR OF NE 1/4 OF SW 1/4 TH N 88-05-42 W 701.10 FT TO WLY MGN SD SOUTHCENTER PARKWAY TH ALG SD WLY MGN S 01-08-45 W 10.65 FT TH S 01-05-23 W 1305.71 FT TO INTSN WITH S LN OF NE 1/4 OF SW 1/4 TH N 87-55-53 W 621.98 FT TO SW COR OF NE 1/4 OF SW 1/4 TO TPOB TH' N 00-50-36 E 255 FT TH S 87-55-53 E 623.07 FT TAP ON SD WLY MGN OF SOUTHCENTER PARKWAY TH S 01-05-23 W 254.98 FT TO S LN SD SUBD TH N 87-55-53 W 621.98 FT TO TPOB VICINITY MAP NO SCALE o� SITE ---MAP Qy NO MALE Pinch: nicat ..ffElsstricat .0• Plumbing 0106as Piping City of Tukwila t.iF' Oi1/( ICON ISSUE FOR PERMIT Hermanson Company LLP 1221 2nd Avenue North Kent, Washington 98032 Tel: (206) 575-9700 Fax: (206) 575-9800 www.hermanson.com Contractor Reg #: HERMACLO05BJ URGENT CARE TUKWILA PRECOR 17275 SOUTHCENTER PARKWAY TUKWILA, WA 98188 FILE COPY r a��i lij✓teY:Y Y (v.� , .I I1.Y i 1 ....� tr.J [ . .......1 ' Oy: Date• Revisions 02/26/16 JMH ISSUE FOR PERMIT No. Date By Description Design Team Design JMH Drawn FVP Checked MIG Scale AS NOTED Drawing Number C-0589-08037 Project Number 11-16-08037 Issue Date 02/24/16 LEGEND, ABBREVIATIONS, GENERAL NOTES & SHEET N D EX- ��D FCS CODE COMPLIANCE CODE APPROVED N MAR 2 5 2016' - City ofTLikwila BUILDING DIVISION DRAWING INDEX SHEET NO. SHEET TITLE CURRENT REVISION M0.00 LEGEND ABBREVIATIONS GENERAL NOTES & SHEET INDEX - HVAC M0.01 SCHEDULES SHEET - HVAC M2.01 PARTIAL 1ST FLOOR PLAN - HVAC M2.R1 PARTIAL ROOF PLAN - HVAC REVISIONS No than, ^ 5h?Il he, rn.,7do to the scope 0 �^1orl< withct.,t prior e ;proval of Tukwila Building Division. NOTE: Revisions will require n newi p!�:n submittal and may include additional p!c.n reviavr fees. APN NUMBER 2623049063 LEGAL DESCRIPTION LOT 1 OF CITY OF TUKWILA SHORT PLAT NO 80 -45 -SS RECORDING NO 8106040707 SD PLAT DAF - POR NE 1/4 OF SW 1/4 LY WLY OF SOUTHCENTER PARKWAY & LY ELY OF INTERSTATE HWY 5 - COMM NE COR OF NE 1/4 OF SW 1/4 TH N 88-05-42 W 701.10 FT TO WLY MGN SD SOUTHCENTER PARKWAY TH ALG SD WLY MGN S 01-08-45 W 10.65 FT TH S 01-05-23 W 1305.71 FT TO INTSN WITH S LN OF NE 1/4 OF SW 1/4 TH N 87-55-53 W 621.98 FT TO SW COR OF NE 1/4 OF SW 1/4 TO TPOB TH' N 00-50-36 E 255 FT TH S 87-55-53 E 623.07 FT TAP ON SD WLY MGN OF SOUTHCENTER PARKWAY TH S 01-05-23 W 254.98 FT TO S LN SD SUBD TH N 87-55-53 W 621.98 FT TO TPOB VICINITY MAP NO SCALE o� SITE ---MAP Qy NO MALE Pinch: nicat ..ffElsstricat .0• Plumbing 0106as Piping City of Tukwila t.iF' Oi1/( ICON ISSUE FOR PERMIT Hermanson Company LLP 1221 2nd Avenue North Kent, Washington 98032 Tel: (206) 575-9700 Fax: (206) 575-9800 www.hermanson.com Contractor Reg #: HERMACLO05BJ URGENT CARE TUKWILA PRECOR 17275 SOUTHCENTER PARKWAY TUKWILA, WA 98188 FILE COPY r a��i lij✓teY:Y Y (v.� , .I I1.Y i 1 ....� tr.J [ . .......1 ' Oy: Date• Revisions 02/26/16 JMH ISSUE FOR PERMIT No. Date By Description Design Team Design JMH Drawn FVP Checked MIG Scale AS NOTED Drawing Number C-0589-08037 Project Number 11-16-08037 Issue Date 02/24/16 LEGEND, ABBREVIATIONS, GENERAL NOTES & SHEET N D EX- ��D FCS CODE COMPLIANCE CODE APPROVED N MAR 2 5 2016' - City ofTLikwila BUILDING DIVISION EXISTING GAS PACKAGED ROOFTOP UNIT SCHEDULE 02/25/16 UNIT TAG LOCATION SERVES BASIS OF DESIGN ESP SUPPLY IN CFM WG SEER/EER COOLING CAPACITY GAS HEATING CAPACITY LAST UPDATED; SOUND OPERATING ELEC PER ARI 270/370 WEIGHT MCA MAX FUSE / PH (Dba) (LBS REMARKS TOTAL MBH SENS MBH INPUT MBH OUTPUT MBH AFUENG CONN RTU -1 ROOF (URGENT CARE TRANE YSC0060A4RLA-D1 2000 1.00 10.2 63 48 60 48 80 1/2 16.3 25 460/3 82 741 1 RTU -2 ROOF (URGENT CARE TRANE YSC0060A4RLA-D1 1 2 000 1.00 10.2 63 48 1 60 48 1 80 1 1/2 16.3 25 460/3 82 741 1 1 REMARKS: 1 UNIT IS EXISTING ,AND SCHEDULE IS PROVIDED FOR REFERENCE ONLY REMARKS: 1 ELECTRICAL CONTE RACTOR TO PROVIDE SCCR PROTECTION FOR EQUIPMENT AS REQUIRED BY NATIONAL ELECTRICAL CODE. MANUFACTURER ITO PROVIDE SCCR LISTING (5 KAIC MINIMUM) INSIDE CONTROL PANEL AS REQUIRED BY NATIONAL ELECTRICAL CODE. 2 ELECTRICAL DISC(DNNECT AND MOTOR STARTER (AS REQUIRED) BY ELECTRICAL CONTRACTOR 3 FAN TO OPERATE DURING BUILDING OCCUPIED HOURS THROUGH BUILDING EMS BY CONTROLS CONTRACTOR 4 MOTOR TO BE ECM (OR 70% MINIMUM EFFICIENCY) PER ENERGY CODE C403.2.10.3 FOR MOTORS GREATER OR EQUAL TO 1/12 HP & LESS THAN 1 HP 5 CONTRACTOR TO VERIFY AND PROVIDE ALL EQUIPMENT REQUIRED BY MANUFACTURER 6 FOR TRADE COORUMNATION REFER TO APPROVED EQUIPMENT SUBMITTALS 7 INSTALL PER MANIUFACTURER RECOMMENDATION 8 FIELD COORDINAITE EXACT UNIT LOCATION TRANSFER RETURN / FAN SCHEDULE AIR GRILLE LAST UPDATED; 02/08/ J 6 UNIT TAG LOCATION AREA SERVED BASIS OF DESIGN MOUNTING TYPE LOCATION CFM ESP MOTOR IN WG BHP HP/W SYSTEM ELECT VFD DAMPER V/PH SOUND WEIGHT SONES LBS REMARKS EFR-01 ROOF TOILETS G'HECK G -085 -VG ROOF CAP CURB 220 0.5 0.06 1/10 ECM - 115/1 7 28 1-8 EFR-02 ROOF TOILETS G'HECK G -085 -VG ROOF CAP CURB 140 0.5 0.04 1/10 ECM - 115/1 7 28 1-8 REMARKS: 1 ELECTRICAL CONTE RACTOR TO PROVIDE SCCR PROTECTION FOR EQUIPMENT AS REQUIRED BY NATIONAL ELECTRICAL CODE. MANUFACTURER ITO PROVIDE SCCR LISTING (5 KAIC MINIMUM) INSIDE CONTROL PANEL AS REQUIRED BY NATIONAL ELECTRICAL CODE. 2 ELECTRICAL DISC(DNNECT AND MOTOR STARTER (AS REQUIRED) BY ELECTRICAL CONTRACTOR 3 FAN TO OPERATE DURING BUILDING OCCUPIED HOURS THROUGH BUILDING EMS BY CONTROLS CONTRACTOR 4 MOTOR TO BE ECM (OR 70% MINIMUM EFFICIENCY) PER ENERGY CODE C403.2.10.3 FOR MOTORS GREATER OR EQUAL TO 1/12 HP & LESS THAN 1 HP 5 CONTRACTOR TO VERIFY AND PROVIDE ALL EQUIPMENT REQUIRED BY MANUFACTURER 6 FOR TRADE COORUMNATION REFER TO APPROVED EQUIPMENT SUBMITTALS 7 INSTALL PER MANIUFACTURER RECOMMENDATION 8 FIELD COORDINAITE EXACT UNIT LOCATION TRANSFER RETURN / EXHAUST AIR GRILLE SCHEDULE TYPE NECK SIZE :N DIA MAX CFM CORE SIZE FACE SIZE NC MOUNTING LAST UPDATED: 2/25/2016 UNIT TAG BASIS OF DESIGN MAX NECK SIZE CFM IN DIA MOUNTING FACE SIZE MATERIAL REMARKS EC1 PRICE 80 TB 500 -- -- T -BAR 24x 12 ALUMINUM 2 9 10 EC2 PRICE 80 TB 1,000 -- -- T -BAR 24 x 24 ALUMINUM 2, 9, 10 EC3 I PRICE 80 TB 2,00 -- -- T -BAR 24 x 48 ALUMINUM 2 9 10 EC4 PRICE 80 F 500 -- -- SURFACE MOUNT 24 x 12 ALUMINUM 2 3 9 10,12 EC5 PRICE 80 F 1,000 -- -- SURFACE MOUNT - 24 x 24 ALUMINUM 2 3 9 10,12 EC6 PRICE 80 F 2,000 -- -- SURFACE MOUNT 24 x 48 ALUMINUM 2 3 9 10 12 Rl PRICE 80 TB 110 6 T -BAR 24 x 12 ALUMINUM 1,5,7/8,9 R2 PRICE 80 TB 230 8 T -BAR 24x 12 ALUMINUM 1,5,7/8,9 R3 PRICE 80 TB 350 10 T -BAR 24 x 12 ALUMINUM 1,5,7/8,9 R4 PRICE 80 TB 600 12 T -BAR 24 x 12 ALUMINUM 1,5,7/8,9 R5 PRICE 80 TB 900 14 T -BAR 24 x 24 ALUMINUM 1,5,7/8,9 R6 PRICE 80 TB 1,200 16 T -BAR 24 x 24 ALUMINUM 1,5,7/8,9 R7 I PRICE 80 TB 1,600 18 T -BAR 24 x 24 ALUMINUM 1,5,7/8,9 R8 PRICE 80 TB 2,400 20 T -BAR 24 x 48 ALUMINUM 1,5,7/8,9 R9 PRICE 80 TB 3,000 22 T -BAR 24 x 48 ALUMINUM 1,5,7/8,9 R10 PRICE 80 TB 3,200 24 T -BAR 24 x 48 ALUMINUM 1,3,7/8,9 G1 PRICE 630DF 150 -- -- GWB 8 x 8 STEEL 3,6,7/8,9, 12 G2 I PRICE 630DF 250 -- -- GWB lox 10 STEEL 3 6 7/8 9,12 G3 PRICE 630DF 375 -- -- GWB 12 x 12 STEEL 3 6 7/8 9,12 G4 PRICE 630DF 525 -- -- GWB 14 x 14 STEEL 3,6,7/8,9, 12 G5 PRICE 630DF 600 -- -- GWB 16 x 16 STEEL 3,6,7/8,9, 12 G6 PRICE 630DF 900 -- -- GWB 18 x 18 STEEL 3,6,7/8,9, 12 G7 I PRICE 630DF 1,200 -- -- GWB 24 x 24 STEEL 3,6,7/8,9, 12 G8 PRICE 630DF 2,400 -- -- GWB 24 x 48 STEEL 3,6,7/8,9, 12 G9 PRICE 630DF 150 8 GWB 8 x 8 STEEL 1 3 6 7/8 9 12 G10 PRICE 630DF 250 10 GWB lox 10 STEEL 1 3 6 7/8 9,12 G11 PRICE 630DF 375 12 GWB 12 x 12 STEEL 1 3 6 7/8 9 12 G12 PRICE 630DF 525 14 GWB 14 x 14 STEEL 1 3 6 7/8 9,12 G13 PRICE 630DF 600 14 GWB 16 x 16 STEEL 1, 3, 6, 7/8 9, 12 G14 PRICE 630DF 900 16 GWB 18 x 18 STEEL 1 3 6 7/8 9 12 G15 PRICE 630DF 1,200 16 GWB 24 x 24 STEEL 1 3 6 7/8, 9,12 G16 PRICE 630DF 2,400 20 GWB 24 x 48 STEEL 1, 3, 6 7/8, 9,12 T1 PRICE 630F 150 -- -- GWB 8 x 8 STEEL 3,7/8,9, 12 T2 PRICE 630F 250 -- -- GWB 10 x 10 STEEL 3,7/8,9, 12 T3 PRICE 630F 375 -- -- GWB 12 x 12 STEEL 3,7/8,9, 12 T4 PRICE 630F 525 -- -- GWB 14 x 14 STEEL 3,7/8,9, 12 T5 PRICE 630F 600 -- -- GWB 16 x 16 STEEL 3,7/8,9,12 T6 PRICE 630F 900 -- -- GWB 18 x 18 STEEL 3,7/8,9,12 T7 PRICE 630F 1,20 -- -- GWB 24 x 24 STEEL 3,7/8,9,12 T8 PRICE 630F 2,400 -- -- GWB 24 x 48 STEEL 3,7/8,9,12 T9 PRICE 630F 150 8 GWB 8 x 8 STEEL 1,3,7/8,9, 12 T10 PRICE 630F 250 10 GWB lox 10 STEEL 1 3 7/8 9 12 Tll PRICE 630F 375 12 GWB 12 x 12 STEEL 1 3 7/8 9 12 T12 PRICE 630F 525 14 GWB 14 x 14 STEEL 1 3 7/8, 9 12 T13 PRICE 630F 600 14 GWB 16 x 16 STEEL 1, 3, 7/8, 9, 12 T14 PRICE 630F 900 16 GWB 18 x 18 STEEL 1 1 3 7/8, 9 12 T15 PRICE 630F 1,200 16 GWB 24 x 24 STEEL 1 3 7/8 9 12 T16 PRICE 630F 2,400 20 GWB 24 x 48 STEEL 1, 3, 7/8, 9, 12, 12 REMARKS: 1 RUNOUT SAME AS D)WG NECK SIZE U.N.O. ON DWG 2 CORE ONLY - LAY-INI 3 SURFACE MOUNT FRAME 4 CHANNEL FRAME - UAY-IN 5 T -BAR LAY -IN 6 PROVIDE OPPOSED 03LADE DAMPER (OBD) 7 PROVIDE DUCTBOARD PLENUM 8 PROVIDE SHEETMET-AL PLENUM 9 STANDARD #26 WHITE FINISH 10 PROVIDE ALUMINUM( GRILLES IN SHOWERS/HUMID AREAS 11 ALL NON-FERROUS MATERIALS IN MRI ROOMS 12 WHERE VOLUME DAMPERS ARE NOT ACCESSIBLE, PROVIDE HAND HOLE ACCESS OR YOUNGS REGULATOR WITH CEILING PLATE OR DURODYNE CABLE OPERATED DAMPER WITH CABLE ROUTED INSIDE DUCT & ADJUSTMENT THROUGH GRILLE FACE REMARKS: 1 RUN OUT SIZE SAME SIZE AS DIFFUSERNECK SIZE, U.N.O. ON DWGS. 2 ALL DIFFUSERS TO HAVE SIDE INLET SFEET METAL CAN PLENUM IF < 1.5 DIA STRAIGHT FLEX AVAILABLE FOR TOP INLET 3 ECCO MFG DIFFUSER CAN TO HAVE PERFORATED INTERIOR PLATE (AND 1" SOUNDLINING IF SPACE <- NC -30 OR SAT < 55°F) 4 STANDARD WHITE POWDER COAT 5 PROVIDE FRAME 3P, LAY -IN TYPE. 6 PROVIDE SURFACE MOUNTING FRAME MODEL SMF FOR GRILLE REMOVAL & INSTALLATION IN HARD LID CEILING 7 WHERE VOLUME DAMPERS ARE NOT ACCESSIBLE, PROVIDE HAND HOLE ACCESS OR YOUNGS REGULATOR WITH CEILING PLATE OR DURODYNE CABLE OPERATED DAMPER WITH CABLE ROUTED INSIDE DUCT & ADJUSTMENT THROUGH GRILLE FACE RECEIVED CITY OF TUKWILA MAR 0 8 2016 PERMIT CENTER Hermanson Company LLP 1221 2nd Avenue North Kent, Washington 98032 Tel: (206) 575-9700 Fax: (206) 575-9800 www.hermanson.com Contractor Reg #: HERMACLO05BJ URGENT CARE TUKWILA PRECOR 17275 SOUTHCENTER PARKWAY TUKWILA, WA 98188 Revisions _ 02/26/16 JMH ISSUE FOR PERMIT No. Date By Description Design Team Design JMH Drawn FVP Checked MIG Scale AS NOTED Drawing Number C-0589-08037 Project Number 11-16-08037 Issue Date 02/24/16 SCHEDULE SHEET Hv s` -REVIEWED OR CODE COMPLIAW APPROVED MAR 2 5 2116 City Of Tukwila BUILDING DIVISION MODULAR DIFFUSER SCHEDULE LAST UPDATED: 02/25/16 UNIT TAG BASIS OF DESIGN TYPE NECK SIZE :N DIA MAX CFM CORE SIZE FACE SIZE NC MOUNTING MATERIAL REMARKS DT1 PRICE SMCD/3P MODULAR 6 110 6 X 6 24 X 24 T -BAR STEEL 1,2,3,4,5 DT2 PRICE SMCD/3P MODULAR 8 230 8 X 8 24 X 24 T -BAR STEEL 1,2,3 4,5 DT3 PRICE SMCD 3P MODULAR 10 350 10 X 10 24 X 24 T -BAR STEEL 1,2,3,4,5 DT4 PRICE SMCD/3P MODULAR 12 500 12 X 12 24 X 24 T -BAR STEEL 1,2,3,4,5 DT5 PRICE SMCD 3P MODULAR 12 600 14X 14 24 X 24 T -BAR STEEL 1,2,3,4,5 DT6 PRICE SMCD/3P MODULAR 14 880 16 X 16 24 X 24 T -BAR STEEL 1 2 3 4 5 DT7 PRICE SMCD/3P MODULAR 16 1,120 18 X 18 24 X 24 T -BAR STEEL 1,2,3,4,5 DG1 PRICE SMCD 6 MODULAR 6 110 6 X 6 -- -- SURFACE STEEL 1,2,3,4,5,6,7 DG2 PRICE SMCD/6 MODULAR 8 230 8 X 8 -- -- SURFACE STEEL 1,2,3,4,5,6,7 DG3 PRICE SMCD 6 MODULAR 10 350 lox 10 -- -- SURFACE STEEL 1,2,3,4,5,6,7 DG4 PRICE SMCD 6 MODULAR 12 500 12 X 12 - -- SURFACE STEEL 1,2,3,4,5,6,7 DG5 PRICE SMCD/6 MODULAR 12 600 14 X 14 -- -- SURFACE STEEL 1,2,3,4 5,6,7 DG6 PRICE SMCD/6 MODULAR 14 880 16 X 16 - -- SURFACE STEEL 1,2,3,4,5,6,7 DG7 PRICE SMCD/6 MODULAR 16 1,120 18 X 18 - -- SURFACE I STEEL 1 2 3 4 5 6 7 REMARKS: 1 RUN OUT SIZE SAME SIZE AS DIFFUSERNECK SIZE, U.N.O. ON DWGS. 2 ALL DIFFUSERS TO HAVE SIDE INLET SFEET METAL CAN PLENUM IF < 1.5 DIA STRAIGHT FLEX AVAILABLE FOR TOP INLET 3 ECCO MFG DIFFUSER CAN TO HAVE PERFORATED INTERIOR PLATE (AND 1" SOUNDLINING IF SPACE <- NC -30 OR SAT < 55°F) 4 STANDARD WHITE POWDER COAT 5 PROVIDE FRAME 3P, LAY -IN TYPE. 6 PROVIDE SURFACE MOUNTING FRAME MODEL SMF FOR GRILLE REMOVAL & INSTALLATION IN HARD LID CEILING 7 WHERE VOLUME DAMPERS ARE NOT ACCESSIBLE, PROVIDE HAND HOLE ACCESS OR YOUNGS REGULATOR WITH CEILING PLATE OR DURODYNE CABLE OPERATED DAMPER WITH CABLE ROUTED INSIDE DUCT & ADJUSTMENT THROUGH GRILLE FACE RECEIVED CITY OF TUKWILA MAR 0 8 2016 PERMIT CENTER Hermanson Company LLP 1221 2nd Avenue North Kent, Washington 98032 Tel: (206) 575-9700 Fax: (206) 575-9800 www.hermanson.com Contractor Reg #: HERMACLO05BJ URGENT CARE TUKWILA PRECOR 17275 SOUTHCENTER PARKWAY TUKWILA, WA 98188 Revisions _ 02/26/16 JMH ISSUE FOR PERMIT No. Date By Description Design Team Design JMH Drawn FVP Checked MIG Scale AS NOTED Drawing Number C-0589-08037 Project Number 11-16-08037 Issue Date 02/24/16 SCHEDULE SHEET Hv s` -REVIEWED OR CODE COMPLIAW APPROVED MAR 2 5 2116 City Of Tukwila BUILDING DIVISION 1a ON T J SCALE: 4"=1' 1' 3' 5' 10' 15' YW1V1•1\V 1 V DEMO EXISTING DUCTWORK AND DIFFUSER BACK TO UNIT. 25' 2' 4' RECEIVED CITY OF TUKWILA MAR 0 8 2016 PERMIT CENTER ISSUE FOR PERMIT Hermanson Hermanson Company LLP 1221 2nd Avenue North Kent, Washington 98032 Tel: (206) 575-9700 Fax: (206) 575-9800 www.hermanson.com Contractor Reg #: HERMACLO05BJ URGENT CARE TUKWILA PRECOR 17275 SOUTHCENTER PARKWAY TUKWILA, WA 98188 Revisions 02/26/16 JMH ISSUE FOR PERMIT No. Date By Description Design Team Design JMH Drawn FVP Checked MIG Scale AS NOTED Drawing Number C-0589-08037 Project Number 11-16-08037 Issue Date 02/24/16 1ST FLOOR PLAN - HVAC_ REVIEWED FOR CODE COMPLIANCE APPROVED U' u City of Tukwila BUILDING DIVISION SCALE: 4 '=1 ' 1 ' 3' 5' 10' 15' 25' 2' 4' RECEIVED CITY OF TUKWILA MAR 0 8 2016 PERMIT CENTER ISSUE FOR PERMIT Hermanson Company LLP 1221 2nd Avenue North Kent, Washington 98032 Tel: (206) 575-9700 Fax: (206) 575-9800 www.hermanson.com Contractor Reg #: HERMACLO05BJ URGENT CARE TUKWILA PRECOR 17275 SOUTHCENTER PARKWAY TUKWILA, WA 98188 Revisions 02/26/16 JMH ISSUE FOR PERMIT No. Date By Description Design Team Design JMH Drawn FVP Checked MIG Scale AS NOTED Drawing Number C-0589-08037 Project Number 11-16-08037 Issue Date 02/24/16 M=�E V &IEvvEO Ft3R C®DE COMPLIANCE APPROVED MAR 2 5 2010 City of Tul(wila BUILDING DIVISION