HomeMy WebLinkAboutPermit M16-0038 - MULTICARE - RTU, DUCT AND RESTROOM EXHAUST FANSMULTICARE
17275 SOUTHCENTER PKWY
160
M16-0038
City of Tukwila
Department of Community Development
• 6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206-431-3670
Inspection Request Line: 206-438-9350
Web site: http://www.Tukwi[aWA.Rov
MECHANICAL PERMIT
Parcel No: 2623049063 Permit Number: M16-0038
Address: 17275 SOUTHCENTER PKWY 160 Issue Date: 3/29/2016
Permit Expires On: 9/25/2016
Project Name: MULTICARE
Owner:
Name: MASAO
2012
Address: 117 E LOUISA #230 C/O SCR LLC,
2014
SEATTLE, WA, 98102
2012
Contact Person:
2014
Name: TERESE ANDERSON
Phone: (253) 796-5825
Address: 1221 SECOND AVE N, KENT, WA,
2014
98032
2012
Contractor:
2012
Name: HERMANSON COMPANY LLP
Phone: (206) 575-9700
Address: 1221 2ND AVE N, KENT, WA, 98032-
2945
License No: HERMACLO05BJ
Expiration Date: 8/25/2016
Lender:
Name:
Address:
DESCRIPTION OF WORK:
TIE INTO 2 EXISTING RTU'S AND DUCT TO NEW TENANT LAYOUT. ADD 2 EXHAUST FANS FOR RESTROOM EXHAUST
Valuation of Work: $30,000.00
Fees Collected: $585.58
Type of Work: REPLACEMENT
Electrical Service Provided by: PUGET SOUND ENERGY
Fuel type: ELECT
Water District: TUKWILA
Sewer District: TUKWILA SEWER SERVICE
Current Codes adopted by the City of Tukwila:
International Building Code Edition:
2012
National Electrical Code:
2014
International Residential Code Edition:
2012
WA Cities Electrical Code:
2014
International Mechanical Code Edition:
2012
WAC 296-466:
2014
Uniform Plumbing Code Edition:
2012
WA State Energy Code:
2012
International Fuel Gas Code:
2012
Permit Center Authorized Signature:
I hearby certify that I have read and examined this permit and know the same to be true and correct. All
provisions of law and ordinances governing this work will be complied with, whether specified herein or not.
The granting of this permit does not presume to give authority to violate or cancel the provisions of any other
state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this
development permy a •awe to the conditions attached to this permit.
Signature:
Print Nam
Dater 2216
This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if
the work is suspended or abandoned for a period of 180 days from the last inspection.
PERMIT CONDITIONS:
1: Work shall be installed in accordance with the approved construction documents, and any changes made
during construction that are not in accordance with the approved construction documents shall be
resubmitted for approval.
2: All permits, inspection record card and approved construction documents shall be kept at the site of work
and shall be open to inspection by the Building Inspector until final inspection approval is granted.
3: All construction shall be done in conformance with the Washington State Building Code and the
Washington State Energy Code.
4: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the
City of Tukwila Building Department (206-431-3670).
5: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila
Permit Center.
6: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an
approval of, any violation of any of the provisions of the building code or of any other ordinances of the City
of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other
ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction
documents and other data shall not prevent the Building Official from requiring the correction of errors in
the construction documents and other data.
7: `MECHANICAL PERMIT CONDITIONS'
8: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila
Permit Center (206/431-3670).
9: Manufacturers installation instructions shall be available on the job site at the time of inspection.
PERMIT INSPECTIONS REQUIRED
Permit Inspection Line: (206) 438-9350
1800 MECHANICAL FINAL
0609 PIPE/DUCT INSULATION
0701 ROUGH -IN MECHANICAL
CITY OF TUKWILA
Community Development Department
• Permit Center
• 6300 Southcenter Blvd., Suite 100
Tukwila, WA 98188
http://www.TukwilaWA.Pov
Mechanical Permit No. M I [,1— QV
Project No.
Date Application Accepted:
Date Application Expires: 9 !3�L Q
use
MECHANICAL PERMIT APPLICATION
Applications and plans must be complete in order to be accepted for plan review.
Applications will not be accepted through the mail or by fax.
**please print**
SITE LOCATION :A
King Co Assessor's Tax No.: 2623049063
Site Address: 17275 Southcenter Pkwy Suite Number: Floor:
Tenant Name: Multicare New Tenant:
0.....Yes ❑..No
PROPERTY OWNER
Name: Multicare Health Systems
Address: 315 Martin Luthar King Way
City: Tacoma State: WA Zip: 98415
CONTACT PERSON — person receiving all project
communication
Name: Terese Anderson
Address: 1221 2nd Ave N
City: Kent State: WA Zip: 98032
Phone: (206) 200-7804 Fax:
Email: tanderson@hermanson.com
Valuation of project (contractor's bid price): $ 30,000
Describe the scope of work in detail:
MECHANICAL CONTRACTOR INFORMATION
Company Name: Hermanson Company
Address: 1221 2nd Ave N
City: Kent State: wA Zip: 98032
Phone: (206) 200-7804 Fax:
Contr Reg No.: HERMACLO05BJ Exp Date: 08/16/2016
Tukwila Business License No.: BUS -0994464
Tie into two existing RTUs and duct to new tenent layout. Add 2 exhaust fans for restroom exhaust.
Use: Residential:
New ..........
❑
Replacement ........
❑
Commercial:
New ..........
❑
Replacement ........
❑
Fuel Type: Electric.....
❑
Gas.......
❑ Other:_
HdApplicationfforms-Applications On Linet2011 Applications\Mcchaniwl Permit Application Rmscd 8-9-11.docx
Revised: August 2011 Pagel of 2
bb
Indicate type of mechanical work being installed and the quantity below:
Unit Type
Qty
Furnace <I 00k btu
Furnace >I 00k btu
Floor furnace
Suspended/wall/floor
mounted heater
Appliance vent
Repair or addition to
heat/refhg/cooling
system
Air handling unit
<10,000 cfm
Unit Type
Qty
Air handling unit
>I0,000 cfm
Evaporator cooler
Ventilation fan
connected to single duct
Ventilation system
Hood and duct
Incinerator — domestic
Incinerator—
comm/industrial
PERMIT APPLICATION NOTES -
Unit Type
Qty
Fire damper
Diffuser
Thermostat
Wood/gas stove
Emergency enerator
Other mechanical
equipment
Boiler/Compressor Qty
0-3 hp/100,000 btu
3-15 h /500,000 btu
15-30 hp/1,000,000 btu
30-50 hp/1,750,000 btu
50+hp/l, 50,000 btu
Value of construction — in all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject
to possible revision by the permit center to comply with current fee schedules.
Expiration of plan review — applications for which no permit is issued within 180 days following the date of application shall expire by limitation.
The building official may grant one extension of time for additional periods not to exceed 90 days each. The extension shall be requested in writing
and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition).
I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER
PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT.
BUILDING OWNER OR
Date: 03/08/2016
Print Name: TereSe Anderson Day Telephone: (206) 200-7804
Mailing Address: 1221 2nd Ave N
Kent WA 98032
City State Zip
H:WpplicationskForms-Applications On Line\2011 Applicatiom\Mmhanical Permit Appliwlion Revised 8-9-1 I.docx
Rmscd: August 2011 Page 2 of 2
bh
DESCRIPTIONS
PermitTRAK
ACCOUNT QUANTITY
PAID
$1,112.74
M16-0038 Address: 17275 SOUTHCENTER PKWY BLDG Apn: 2623049063
$585.58
MECHANICAL
$563.06
PERMIT ISSUANCE BASE FEE
R000.322.100.00.00
0.00
$32.50
PERMIT FEE
R000.322.100.00.00
0.00
$417.95
PLAN CHECK FEE
R000.322.102.00.00
0.00
$112.61
TECHNOLOGY FEE
$22.52
TECHNOLOGY FEE
R000.322.900.04.00
0.00
$22.52
PG16-0029 Address: 17275 SOUTHCENTER PKWY BLDG Apn: 2623049063
$527.16
PLUMBING
$506.88
PERMIT ISSUANCE BASE FEE
R000.322.100.00.00
0.00
$32.50
PERMIT FEE
R000.322.100.00.00
0.00
$373.00
PLAN CHECK FEE
R000.322.103.00.00
0.00
$101.38
TECHNOLOGY FEE
$20.28
TECHNOLOGY FEE
TOTAL FEES PAID
R000.322.900.04.00
0.00
$20.28
Date Paid: Tuesday, March 08, 2016
Paid By: TERESE ANDERSON
Pay Method: CREDIT CARD 989771
Printed: Tuesday, March 08, 2016 2:45 PM 1 of 1
SYSTEMS
INSPECTION RECORD
Retain a copy with permit I M41 4J 30
INSP ON N0. PERMIT N0.
CITY OF TUKWILA BUILDING DIVISION
6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670
Permit Inspection Request Line (206) 438-9350
Project:
Type of Inspection:
Address:
Date Called:
Special Instructions:
Date Wantd:/
p.m.
Requester:
Phone No:
Approved per applicable codes. tl Corrections required prior to approval.
fZ//(�
REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be
paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection.
INSPECTION RECORD Vr
, 6;
Retain a copy with permitFM-16
003
INSPECTION NO. PERMIT NO.
CITY OF TUKWILA BUILDING DIVISION
6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670
Permit Inspection Request Line (206) 438-9350
Project:
fA rZ r-
Type
I-1
of In. pection:
W- vC?' 4J9(A-A1TA.1
Address:
17v Cta�lll?
Date Called:
Special Instructions:
Date Wanted:
Requester.
Phone No:
AApproved per applicable codes. 11 Corrections required prior to approval.
Inspector:
REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be
paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection.
INSPECTION RECORD
Retain a copy with permit ml& -o638
INSPECTION NO. PERMIT NO.
CITY OF TUKWILA BUILDING DIVISION
6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670
Permit Inspection Request Line (206) 438-9350
Project:
Tyl2e of Inspection/:
QC
N
Address:
Date Called:
J-7z75'-SA11)4(6JrM 1,
Special Instructions:
Date Wanted: At;
Requester: —y e
LAN
Phone No:
WC - 2S -T-- 3 s-9
Approved per applicable codes. L._.! Corrections required prior to approval.
REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be
paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection.
INSPECTION RECORD�Ad0 ��
Retain a copy with permit i'lV
ECTION NO. PERMIT NO.
CITY OF TUKWILA BUILDING DIVISION
6300 Southcenter Blvd., #100, Tukwila. WA 981 (206 431-3§70
Permit Inspection Request Line (206) 438-9350 0
Project
Type of Insp cti
�,: f��/r/�e G �
ddress.
Date Called:
2,15- f6jc t.
`-
Special Instructions:
DateantQd;a.m.
9 GG��JJ p.m.
Requester:
11 R
Phone 6 2--y-5-
00
1 L'7 1L'7
Inspector: Date: 6-2-3
_ f /
REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be
paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection.
r
AHRTEST Co., Inns..
Preliminary Test and Balance
Report
FIRM: Airtest Co Inc
PO Box 86
Issaquah, WA 98027
PHONE: 425-313-0172
FAX: 425-313-5735
PROJECT: Urgent Care
17272 Southcenter Parkway
Tukwila, WA 98188
DATE: 8/10/2016
CONTACT: Luke Holmen
NOTES:
Airtest Cc Inc
PROJECT #: 16-3067-1
Preliminary TAB Report
RECEIVED
CITY OF TUKWILA
AUS 17 2016
PERMIT CENTER
1 of 7
AIRIEST Co., Inc. r(Ej gg
Roof Top Unit
PROJECT: Urgent Care DATE: 8/10/2016
LOCATION: Tukwila, WA CONTACT: Luke Holmen
PROJECT M 16-3067-1
SYSTEM/UNIT: RTU -1
AREA: Staff 123
Unit Data
Unit Manufacturer
Trane
Unit Model Number
YSC060A3RLA015U
Unit Serial Number
647102800L
RTU -1 /Supply Fan
1075 RPM
Fan Type / Class
FC / 1
Test Data
Actual Ext. SP Suction
-0.37 in. we
Actual Ext. SP Discharge
0.30 in. we
Actual Total Ext. SP
0.67 in. we
Fan SP In Actual
-0.70 in. we
Fan SP Out Actual
0.30 in. we
Act. Tot. SP
1.00 in. we
RTU -1 / Supply Fan
Direct Drive
Fan RPM Actual
1010 RPM
A. Tot. Inlet SP
-0.70 in. wc.
A. Tot. Discharge SP
0.30 in. wc.
TSP Actual
1.00 in. wc.
Electrical Test Data
RTU -1 / Supply Fan
Filter Manufacturer
Final Operating Hz
High Speed
Motor Volts 1
208 Volts
Motor Amps 1
4.8 Amps
RTU -1 Supply Outlet Summary
Tested By: Luke Holmen
Test Date: August 04, 2016
Motor Data
RTU -1 /Supply Fan
Outlet
Type
Motor Manufacturer
Emerson
Motor HP
0.9 HP
Motor RPM
1075 RPM
Motor Frame
48Y
Motor Rated Volts
208 Volts
Motor Phase
1
Motor Hertz
60 Hz
Motor FL Amps
5.7 Amps
Motor Service Factor
1.00
Sheave Data
RTU -1 / Supply Fan
80
Drive Type
Direct Drive
Air Test Data
Design GRD Total CFM
2000 CFM
Actual GRD Total CFM
1710 CFM
Return Air CFM Actual
1675 CFM
Filter Data
RTU -1 / Filter Bank
6 x 6
Filter Manufacturer
Airguard
Filter Type
Pleated
MERV Rating
8
Filter Quantity
2
Filter Size
20 x 25 x 1 Inches
System / Unit
Area Served
Outlet
Type
Size LxW
/ D
Design
CFM
Prelim
Reading
Final
Reading
% Final
Outlet -01
Care Team 116
CD
12x 12
450
325
370
82
Outlet -02
Poct 117
CD
6 x 6
100
110
80
80
Outlet-03
IT 118
CD
10 x 10
250
225
235
94
Outlet -04
Storage 119
CD
6 x 6
100
35
90
90
Outlet -05
X -Ray 121
CD
8 x 8
200
160
160
80
Outlet -06
X -Ray 121
CD
8 x 8
200
175
160
80
Outlet -07
Staff 123
CD
8 x 8
150
195
125
83
Outlet -08
Hall 125
CD
8 x 8
175
180
155
89
Outlet -09
Soiled 122
CD
6 x 6
75
80
65
87
Outlet -10
Wellness Suite 115
CD
6 x 6
100
105
90
90
Outlet -11
Healing Suite 114
CD
6 x 6
100
100
90
90
Outlet -12
"> C�rrtmunity quite'113
CD
6 x 6
100
60
90
90
Totals:
-
-
2,000
1,760
1,710
86
Airtest Co Inc
Preliminary TAB Report 2 of 7
AIRTEST Co., Inc.
Roof Top Unit
PROJECT: Urgent Care
LOCATION: Tukwila, WA
PROJECT M 16-3067-1
SYSTEM/UNIT: RTU -1 (Cont.)
AREA: Staff 123
RTU -1 Return Inlet Summary
DATE: 8/10/2016
CONTACT: Luke Holmen
Tested By: Luke Holmen
Test Date: August 04, 2016
System / Unit
Area Served
Outlet
Type
Size LxW
/ D
Design
CFM
Prelim
Reading
Final
Reading
% Final
Inlet -1
Hall 125
RG
24 x 24
RTU -1 / Outlet -03
1675
1675
Damper closed 100%
RTU -1 / Outlet -03
Totals :
-
-
-
1,676
1,676
0%
* Notes
RTU -1
4 -Aug -16
Luke Holmen
Economizer did not seem to be operating
RTU -1
4 -Aug -16
Luke Holmen
Unit balanced in 100% return mode at 86% of
design, motor is running on high speed.
RTU -1 / Outlet -03
4 -Aug -16
Luke Holmen
Damper closed 100%
RTU -1 / Outlet -03
3 -Aug -16
Luke Holmen
Read with a Velgrid
Airtest Co Inc
Preliminary TAB Report 3 of 7
Ca,AERTEST�r��o
Roof Top Unit
PROJECT: Urgent Care DATE: 8/10/2016
LOCATION: Tukwila, WA CONTACT: Luke Holmen
PROJECT #: 16-3067-1
SYSTEM/UNIT: RTU -2
AREA: Lobby 101
Unit Data
Unit Manufacturer
Trane
Unit Model Number
YSC060A3RLA015U
Unit Serial Number
647102724L
_RTU -2 / Supply Fan
1075 RPM
Fan Type / Class
FC / 1
Test Data
Actual Ext. SP Suction
-0.46 in. we
Actual Ext. SP Discharge
0.22 in. we
Actual Total Ext. SP
0.68 in. we
Fan SP In Actual
-0.86 in. we
Fan SP Out Actual
0.22 in. we
Act. Tot. SP
1.08 in. we
RTU -2 / Supply Fan
Direct Drive
Fan RPM Actual
966 RPM
A. Tot. Inlet SP
-0.87 in. wc.
A. Tot. Discharge SP
0.22 in. wc.
TSP Actual
1.09 in. wc.
Electrical Test Data
RTU -2 / Supply Fan
Filter Manufacturer
Final Operating Hz
High Speed
Motor Volts 1
207 Volts
Motor Amps 1
4.7 Amps
Airtest Co Inc
Tested By: Luke Holmen
Test Date: August 04, 2016
Motor Data
RTU -2 / Supply Fan
Motor Manufacturer
Emerson
Motor HP
0.9 HP
Motor RPM
1075 RPM
Motor Frame
48Y
Motor Rated Volts
208 Volts
Motor Phase
1
Motor Hertz
60 Hz
Motor FL Amps
5.7 Amps
Motor Service Factor
1.00
Sheave Data
RTU -2 / Supply Fan
Drive Type
Direct Drive
Air Test Data
Design GRD Total CFM
2000 CFM
Actual GRD Total CFM
1835 CFM
Return Air CFM Actual
1500 CFM
Filter Data
RTU -2 / Filter Bank
Filter Manufacturer
Airguard
Filter Type
Pleated
MERV Rating
8
Filter Quantity
2
Filter Size
20 x 25 x 2 Inches
Preliminary TAB Report 4 of 7
I
AIRTEST Co., Inc. rf��gg
Roof Top Unit
PROJECT: Urgent Care DATE: 8/10/2016
LOCATION: Tukwila, WA CONTACT: Luke Holmen
PROJECT M 16-3067-1
SYSTEM/UNIT: RTU -2 (Cont.)
AREA: Lobby 101
RTU -2 Supply Outlet Summary
Tested By: Luke Holmen
Test Date: August 04, 2016
System / Unit
Area Served
Outlet
Type
Size LxW
/ D
Design
CFM
Prelim
Reading
Final
Reading
% Final
Outlet -01
Family Suite 109
CD
8 x 8
125
105
120
96
Outlet -02
Technology Suite 110
CD
8 x 8
125
160
115
92
Outlet -03
Knowledge Suite 111
CD
8 x 8
125
145
120
96
Outlet -04
Hall 125
CD
6 x 6
85
100
80
94
Outlet -05
Kids Suite 112
CD
6 x 6
100
65
90
90
Outlet -06
Clean + Med 108
CD
6 x 6
100
90
90
90
Outlet -07
Hall 125
CD
6 x 6
100
75
90
90
Outlet -08
Lobby 101
CD
10 x 10
330
255
300
91
Outlet -09
Lobby 101
CD
10 x 10
330
250
300
91
Outlet -10
Hall 125
CD
10'x 10
330
280
300
91
Outlet -11
Scale 105
CD
6 x 6
50
105
45
90
Outlet -12
Check -Out + Copy Scan 106
CD
6 x 6
75
75
70 1
93
Outlet -13
Admin / Manager 107
CD
8 x 8
125
200
11592
Totals:
-
-
2,000
1,905
1,835
92%
RTU -2 Return Inlet Summary
System / Unit
Area Served
Outlet
Type
Size LxW
/ D
Design
CFM
Prelim
Reading
Final
Reading
% Final
Inlet -1
Hall 125
RG
24 x 24
1500
1500
Totals :
-
-
-
1,600
1,600
0%
* Notes
RTU -2 4 -Aug -16 Luke Holmen Economizer did not seem to be operating
RTU -2 3 -Aug -16 Luke Holmen Unit balanced in 100% return mode at 92% of
design, motor is running on high speed.
Airtest Co Inc Preliminary TAB Report 5 of 7
AIRTEST Co., Inc. q��g'g
Fan Unit
PROJECT: Urgent Care DATE: 8/10/2016
LOCATION: Tukwila, WA CONTACT: Luke Holmen
PROJECT #: 16-3067-1
SYSTEMRJNIT: EFR-1
AREA: Restrooms
EFR-1 Exhaust Inlet Summary
Tested By: Luke Holmen
Test Date: August 03, 2016
Motor Data
Motor Manufacturer Greenheck
Motor HP 1/10 HP
Motor RPM 1750 RPM
Motor Rated Volts 120 Volts
Motor Phase 1
Motor Hertz 60 Hz
Motor FL Amps 1.5 Amps
Motor Service Factor 1.0
Sheave Data
Drive Type Direct Drive
Air Test Data
Tot. GRD CFM Des. 150 CFM
Tot. GRD CFM Act. 150 CFM
System / Unit
Unit Data
Unit Location
Roof
Unit Serves
Restrooms
Unit Manufacturer
Greenheck
Model Number
6 -085 -V6 -X
Serial Number
14629646
Fan Type / Class
FC / 1
70
Test Data
Fan RPM Actual
1018 RPM
SP In Actual
-0.006 in. we
SP Out Actual
0.01 in. we
External SP Actual
0.016 in. we
Totals :
Electrical Test Data
Final Operating Hz
1018 RPM
Motor Volts 1
120 Volts
Motor Amps 1
0.2 Amps
EFR-1 Exhaust Inlet Summary
Tested By: Luke Holmen
Test Date: August 03, 2016
Motor Data
Motor Manufacturer Greenheck
Motor HP 1/10 HP
Motor RPM 1750 RPM
Motor Rated Volts 120 Volts
Motor Phase 1
Motor Hertz 60 Hz
Motor FL Amps 1.5 Amps
Motor Service Factor 1.0
Sheave Data
Drive Type Direct Drive
Air Test Data
Tot. GRD CFM Des. 150 CFM
Tot. GRD CFM Act. 150 CFM
System / Unit
Area Served
Outlet
Type
Size LxW
/D
Design
CFM
Prelim
Reading
Final
Reading
% Final
Inlet -1
Men's Toilet 104
EG
6 x 6
70
165
70
100
Inlet -2
Women's Toilet 103
EG
6 x 6
70
115
70
100
Totals :
-
-
140
280
140
1 100%
* Notes
Airtest rn /nr
Preliminary TAB Report 6 of 7
AHRTEST Co., Enco
P
Fan Unit
PROJECT: Urgent Care DATE: 8/10/2016
LOCATION: Tukwila, WA CONTACT: Luke Holmen
PROJECT #: 16-3067-1
SYSTEM/UNIT: EFR-2
AREA: Janitor 124
EFR-2 Exhaust Inlet Summary
Tested By: Luke Holmen
Test Date: August 04, 2016
Motor Data
Motor Manufacturer Greenheck
Motor HP 1/10 HP
Motor RPM 1750 RPM
Motor Rated Volts 120 Volts
Motor Phase 1
Motor Hertz 60 Hz
Motor FL Amps 1.5 Amps
Motor Service Factor 1.0
Sheave Data
Drive Type Direct Drive
Air Test Data
Tot. GRD CFM Des. 220 CFM
Tot. GRD CFM Act. 215 CFM
System / Unit
Unit Data
Unit Location
Roof
Unit Serves
Janitor
Unit Manufacturer
Greenheck
Model Number
6 -085 -V6 -X
Serial Number
14629645
Fan Type / Class
FC / 1
100
100
Inlet -2
Test Data
Fan RPM Actual
1367 RPM
SP In Actual
-0.005 in. we
SP Out Actual
0.01 in. we
External SP Actual
0.015 in. we
Electrical Test Data
Final Operating Hz
1367 RPM
Motor Volts 1
120 Volts
Motor Amps 1
0.5 Amps
EFR-2 Exhaust Inlet Summary
Tested By: Luke Holmen
Test Date: August 04, 2016
Motor Data
Motor Manufacturer Greenheck
Motor HP 1/10 HP
Motor RPM 1750 RPM
Motor Rated Volts 120 Volts
Motor Phase 1
Motor Hertz 60 Hz
Motor FL Amps 1.5 Amps
Motor Service Factor 1.0
Sheave Data
Drive Type Direct Drive
Air Test Data
Tot. GRD CFM Des. 220 CFM
Tot. GRD CFM Act. 215 CFM
System / Unit
Area Served
Outlet
Type
Size LxW
/ D
Design
CFM
Prelim
Reading
Final
Reading
% Final
Inlet -1
Soiled 122
EG
6 RD
100
100
100
100
Inlet -2
Janitor 124
EG
6 RD
50
125
50
100
Inlet -3
Staff 123
EG
I 6 RD
1 70
130
1 65
93
Totals :
I -
- 1
220
365
215
98%
* Notes
Airtest Co /nc
Preliminary TAB Report 7 of 7
PERMIT COORD COPY
PLAN REVIEW/ROUTING SLIP
PERMIT NUMBER: M16-0038
DATE: 03/09/16
PROJECT NAME: MULTICARE
SITE ADDRESS: 17275 SOUTHCENTER PKWY - SUITE 160
X Original Plan Submittal Revision # before Permit Issued
Response to Correction Letter # Revision # after Permit Issued
DEPARTMENTS:
Pri "& II AvA AR x-10-1 P
Building Division Fire Prevention�
Planning Division
❑
Public Works ❑ Structural ❑ Permit Coordinator
PRELIMINARY REVIEW: DATE: 03/10/16
Not Applicable ❑ Structural Review Required ❑
(no approval/review required)
REVIEWER'S INITIALS:
1J.iy:1
APPROVALS OR CORRECTIONS: DUE DATE: 04/07/16
Approved ❑ Approved with Conditions ❑
Corrections Required ❑ Denied ❑
(corrections entered in Reviews) (ie: Zoning Issues)
Notation:
REVIEWER'S INITIALS:
DATE:
Permit Center Use Only
CORRECTION LETTER MAILED:
Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials:
12/16/2013
HERMANSON COMPANY LLP
Home Espanol ' Contact.
Safety & Health Claims & Insurance
Washington State Department of
Caber & Industries
HERMANSON COMPANY LLP
Owner or tradesperson
1221 2ND AVE N
KENT, WA98032-2945
Principals
206-575-9700
NICOLAISEN, KNUT H, PARTNER/MEMBER
KING County
BROCK, DANIEL L, PARTNER/MEMBER
FOX, DEAN M, PARTNER/MEMBER
HENGEL, STEPHEN A, PARTNER/MEMBER
DYCKMAN, KENNETH
A, PARTNER/MEMBER
ROBINETT, PAUL J, PARTNER/MEMBER
HERMANSON, RICHARD
L, PARTNER/MEMBER
ALMON, KEVIN, PARTNER/MEMBER
(End: 08/05/2010)
MACDONALD, JAMES, PARTNER/MEMBER
(End: 08/05/2010)
Doing business as
HERMANSON COMPANY LLP
WA UBI No. Business type
602 004 844 Limited Liability Partnership
Governing persons
CORP
HERMANSON
LLC HERMANSON GROUP;
License
Page 1 of 3
A
Workplace Rights
Verify the contractor's active registration / license / certification (depending on trade) and any past violations.
Construction Contractor Active.
.............................. ..... _........................
Meets current requirements.
https://secure.Ini.wa.gov/verify/Detail.aspx?UBI=602004844&LIC=HERMACL005BJ&SAW= 3/29/2016
MECHANICAL ABBREVIATIONS
A
AMPS
IE
INVERT ELEVATION
AC
AIR CONDITIONING
IEER
INTEGRATED ENERGY EFFICIENCY RATIO
ACH
AIR CHANGES PER HOUR
IMC
INTERNATIONAL MECHANICAL CODE
ACT
ACOUSTICAL CEILING TILE
IN
INCHES
AD
ACCESS DOOR
IN WG
INCHES WATER GAUGE
ADD'L
ADDITIONAL
IPLV
INTEGRATED PART LOAD VALUE
AFF
ABOVE FINISHED FLOOR
KW
KILOWATTS
AFG
ABOVE FINISHED GRADE
LAT
LEAVING AIR TEMPERATURE
AHU
AIR HANDLING UNIT
LB/LBS
POUND/POUNDS
ALUM
ALUMINUM
LF/LIN FT
LINEAL FOOT/FEET
AMP/AMPS
AMPERAGE
LPG
LIQUID PROPANE GAS
AP
ACCESS PANEL
LPS
LOW PRESSURE STEAM
ARCH
ARCHITECT
LVG
LEAVING
BC
BEADED COLLAR
LWA
SOUND POWER RATING LEVEL (IN Ds)
BDD
BACKDRAFT DAMPER
LWG
LOW WALL GRILLE
BF
BELOW FLOOR
LWT
LEAVING WATER TEMPERATURE
BHP
BRAKE HORSEPOWER
MAX
MAXIMUM
BLDG
BUILDING
MAU
MAKE UP AIR UNIT
BOD
BOTTOM OF DUCT
MBH
1000 BRITISH THERMAL UNITS/HOUR
BOP
BOTTOM OF PIPE
MCA
MINIMUM CIRCUIT AMPACITY
BOT
BOTTOM
MD
MOTORIZED DAMPER
BS
BIRD SCREEN / BLACK STEEL
MFR
MANUFACTURER
BTU
BRITISH THERMAL UNIT
MISC
MISCELLANEOUS
BTUH
BRITISH THERMAL UNITS PER HOUR
MIN
MINIMUM/MINUTE
CAP
CAPACITY
MPS
MEDIUM PRESSURE STEAM
CC
CONTROLS CONTRACTOR
MT
MOUNT
CD
CEILING DIFFUSER/CONDENSATE DRAIN
MTD
MOUNTED
CDWR
CONDENSER WATER RETURN
MUW
MAKE-UP WATER
CDWS
CONDENSER WATER SUPPLY
NA
NOT APPLICABLE
CFM
CUBIC FEET PER MINUTE
NC
NORMALLY CLOSED/NOISE CRITERIA
CHWR
CHILLED WATER RETURN
NG/NGAS
NATURAL GAS
CHWS
CHILLED WATER SUPPLY
NIC
NOT IN CONTRACT
CLG
CEILING
NO
NORMALLY OPEN/NUMBER
COL
COLUMN
NPW
NON -POTABLE WATER
CONC
CONCRETE
N -R
NON-RESIDENTIAL
COND
CONDENSATE
OA/OSA
OUTSIDE AIR
CONN
CONNECT/CONNECTED/CONNECTION
OBD
OPPOSED BLADE DAMPER
CONT
CONTINUOUS/CONTINUATION
OD
OUTSIDE DIAMETER/DIMENSION
CONTR
CONTRACTOR
PCF
POUNDS PER CUBIC FOOT
COORD
COORDINATE
PD
PRESSURE DROP
COP
COEFFICIENT OF PERFORMANCE
PH
PHASE
CT
COOLING TOWER
POC
POINT OF CONNECTION
CU
CUBIC/CONDENSER UNIT
P/PRESS
PRESSURE
CW
DOMESTIC COLD WATER/CONDENSER WATER
PSI
POUNDS PER SQUARE INCH
DB
DUCTBOARD/DRY BULB/DECIBEL
PSIG
POUNDS PER SQUARE INCH GAUGE
DDC
DIRECT DIGITAL CONTROL
QTY
QUANITY
DEFL
DEFLECTION
R
RETURN GRILLE/RELOCATED/RETURN
DEG
DEGREE/DEGREES
RA
RETURN AIR
DIA
DIAMETER
RD/RND
ROUND
DMPR
DAMPER
REF
REFERENCE
DN
DOWN
REQ
REQUIRED
DWG
DRAWING
RESID
RESIDENTIAL
EXH
EXHAUST
RF
RELIEF
EA
EACH
RG
REFRIGERANT DISCHARGE GAS
EAT
ENTERING AIR TEMPERATURE
RL
REFRIGERANT LIQUID
EC
EGGCRATE GRILLE/END CAP/ELEC CONTRACTOR
RPM
REVOLUTIONS PER MINUTE
EER
ENERGY EFFICIENT RATING
RS
REFRIGERANT SUCTION
EF
EXHAUST FAN
S
SUPPLY
EFF
EFFICIENCY
SA
SUPPLY AIR
EL
ELEVATION
SAT
SATURATION/SUPPLY AIR TEMPERATURE
ELEC/ELECT ELECTRICAL/ELECTRIC
SD
SMOKE DETECTOR
EMCS
ENERGY MANAGEMENT CONTROL SYSTEM
S/D
SLIP & DRIVE CONNECTION
ENT
ENTERING
S -C
SEATTLE CODE
EQUIP
EQUIPMENT
SEER
SEASONAL ENERGY EFFICIENCY RATING
ESP
EXTERNAL STATIC PRESSURE
SENS
SENSIBLE
EWT
ENTERING WATER TEMPERATURE
SL
SOUND LINED
EXIST
EXISTING
SM
SHEETMETAL
EXH
EXHAUST
SPEC
SPECIFICATION
F
FAHRENHEIT
SO
SCREENED OPENING
FAC
FIRE ALARM CONTRACTOR
SOG
SLAB ON GRADE
FD
FIRE DAMPER
SP
STATIC PRESSURE
FDC
FIRE DEPARTMENT CONNECTION
SF
SQUARE FEET
FF
FINISHED FLOOR
SS
STAINLESS STEEL
FIC
FURNISHED AND INSTALLED BY CONTRACTOR
STRUC
STRUCTURAL
FIO
FURNISHED AND INSTALLED BY OWNER
TA
TRANSFER AIR
FLA
FULL LOAD AMPS
TEMP
TEMPERATURE/TEMPORARY
FLEX
FLEXIBLE
TBD
TO BE DETERMINED
FLR
FLOOR
TOD
TOP OF DUCT
FOB
FLAT ON BOTTOM
TOS
TOP OF STEEL/TOP OF SLAB
FOIC
FURNISHED BY OTHERS,
TOT
TOTAL
INSTALLED BY CONTRACTOR
TSP
TOTAL STATIC PRESSURE
FOS
FLAT ON SIDE
TSTAT
THERMOSTAT
FOT
FLAT ON TOP
TYP
TYPICAL
FP
FIRE PROTECTION
UH
UNIT HEATER
FPM
FEET PER MINUTE
UNO
UNLESS NOTED OTHERWISE
FSD
FIRE/SMOKE DAMPER
V
VOLT
FT
FOOT/FEET
VD
VOLUME DAMPER
FUT
FUTURE
VEL
VELOCITY
FV
FACE VELOCITY
VERT
VERTICAL
G
GRILLE
VFD
VARIABLE FREQUENCY DRIVE
GA
GAUGE/GALLON
VOL
VOLUME
GALV
GALVANIZED
W
WRAPPED DUCT
GC
GENERAL CONTRACTOR
WB
WET BULB
GPM
GALLONS PER MINUTE
WG
WATER GAUGE
GRD
GRILLE/REGISTER/DIFFUSER
W/
WITH
GWB
GYPSUM WALL BOARD
W/0
WITHOUT
HD
HEAD
W/SF
WATTS PER SQUARE FOOT
HORIZ
HORIZONTAL
WSEC
WASHINGTON STATE ENERGY CODE
HP
HORSEPOWER
HR
HOUR
HSPF
HEATING SEASONAL PERFORMANCE FACTOR
HT
HEIGHT
HWTG
HIGH WALL TRANSFER GRILLE
HWR
HOT WATER RETURN
HWS
HOT WATER SUPPLY
HX
HEAT EXCHANGER
HZ
HERTZ
IBC
INTERNATIONAL BUILDING CODE
ICW
INDUSTRIAL COLD WATER
ID
INSIDE DIAMETER/DIMENSION
MECHANICAL LEGEND
10X10 RECT SUWRLY AIR DUCT
,10X10 �
UP/TOWARD
10X10 RECT SUWRLY AIR DUCT
10X�-Q DN/AWAY
10X10 RECT EXHIAUST OR RETURN DUCT
t' 0X10 � UP/TOWARD
10X10 ,' RECT EXHAUST OR RETURN DUCT
,10X� DN/AWAY
100
100 rn, ROUND DIUCT - UP/TOWARD
� 1����� �( ROUND DIUCT - DN/ AWAY
"-l�J
12X100 FLATOVAL DUCT - UP/ TOWARD
12X100;, FIATOVAL DUCT - DN/ AWAY
TOO: DUCT OVERLAP
100
BOOT TAP'
100
100 45 TAP
100 VOLUME [DAMPER
100
RISE(R) 8dc DROP(D)
TRANSITION
TURNING 'VANES/SPLITTERS
t vs) } DUCT M01UP1TED SMOKE DETECTOR
"D� BACK DW4FfT DAMPER
FLEXIBLE DUCT
�
NR FLOWS (FORCED AIR)
COIMBINATION FSD
FIRIE DAMPER
SMIOKE DAMPER
MO)TOR OPERATED DAMPER
ACCESS DOORS
SOIUND TRAP
FLEX CONNECTION
16X16SL ACOUSTICALLY LINED DUCT (SL)
FABRIC DWCT
CLEARANCE
® SUPPLY AIR DIFFUSER
(WITH CODE BLANKOFF)
CEILING RETURN, TRANSFER OR
EXHAUST FAIR GRILLE
SLOTTED 1DFFFUSER (PLAN VIEW)
Q REVISION (CLOUD & TRIANGLE
##0 ROUND DWCT SYMBOL
##X## DEGREES TREES SYMBOL
SiYM OL
® POINT OF CONNECTION
CD1-100 GRD TAG IDENTIFIER = TYPE -CFM
80 SIZE
T T'STAT/TEMP SENSOR ; o CARBON DIOXIDE
H HUMIDITY SENSOR SENSOR
sD SMOKE DETECTOR ; co CARBON MONOXIDE
sP STATIC PRESSURE SENSOR SENSOR
EXISTING DIUCTWORK
MECHANICAL GENERAL NOTES
1. WORK SHALL CONFORM TO APPLICABLE CODES AND REGULATIONS, INCLUDING, BUT NOT LIMITED TO THE 2012 IBC, 2012 WSEC, & 2)12 IMC.
2. DIMENSIONS ARE TO FACE OF STUD, CONCRETE, OR MASONRY UNLESS NOTED OTHERWISE.
3. DO NOT SCALE DRAWINGS. DIMENSIONS GOVERN.
4. VERIFY EXISTING CONDITIONS, DIMENSIONS, DETAILS, ETC. NOTIFY ENGINEER OF ANY DISCREPANCIES PRIOR TO PROCEEDING WITH WORC
5. WHEN CONSTRUCTION DETAILS ARE NOT SHOWN OR NOTED FOR ANY PART OF THE WORK, DETAILS SHALL BE THE SAME
AS FOR OTHER SIMILAR WORK. IF ADDITIONAL QUESTIONS REMAIN, CONTACT THE ENGINEER PRIOR TO PROCEEDING.
6. ALL STRUCTURAL OPENINGS AND PLATFORMS SHALL BE PROVIDED BY THE GENERAL CONTRACTOR UNLESS NOTED OTHERWISE.
7. DUCT SEALING AND CONSTRUCTION TO MEET SMACNA AND ENERGY CODE REQUIREMENTS. UNLESS OTHERWISE NOTED, LOW PRESSURE DUCTWORK
(DOWNSTREAM OF VAV BOXES, CONSTANT VOLUME AC SYSTEMS, TOILET EXHAUSTS, ETC. TO MEET 2" CONSTRUCTION STANDARDS WITH
SEAL CLASS C. MEDIUM PRESSURE DUCTWORK (UPSTREAM OF VAV BOXES, HIGH VELOCITY EXHAUSTS, ETC.) TO MEET 4" CONSTRUCTION STANDARDS
WITH SEAL CLASS A. DUCT RISERS IN SHAFTS WITH DAMPERED PENETRATIONS TO MEET 6" CONSTRUCTION STANDARDS WITH SEAL CLkSS A.
8. ALL CEILING DIFFUSERS ARE 4 -WAY THROW UNLESS NOTED OTHERWISE.
9. ALL DUCT DIMENSIONS ARE CLEAR INSIDE DIMENSIONS AFTER LINING HAS BEEN ACCOUNTED FOR.
10. OUTSIDE AIR INTAKES ON ALL AIR HANDLING UNITS SHALL BE 10 FEET AWAY FROM ANY FUEL BURNING EQUIPMENT OR 3 FEET BELOV
ANY PLUMBING VENT OR EXHAUST OUTLET WITHIN 10 FEET
11. ALL AIR ECONOMIZERS SHALL BE CAPABLE OF THE FOLLOWING:
-0% TO 100% OF THE DESIGN SUPPLY AIR
-CONTROLLED BY A CONTROL SYSTEM DETERMINING IF THE OUTSIDE AIR CAN MEET PART OR ALL OF THE BUILDING COOLING LOADS.
-INTEGRATED TO PROVIDE PARTIAL COOLING EVEN WHEN MECHANICAL COOLING IS REQUIRED.
12. OUTSIDE AIR INTAKE,RELIEF, AND EXHAUST OPENINGS SHALL BE EQUIPPED WITH MOTORIZED (OR GRAVITY DAMPERS PER
EXCEPTIONS IN C403.2.4.4) WHICH CLOSE AUTOMATICALLY WHEN SYSTEM IS OFF OR UPON POWER FAILURE.
13. THE CONTROL SYSTEM SHALL BE 7 -DAY PROGRAMMABLE, CAPABLE OF BEING SET FOR SEVEN (7) DIFFERENT DAY TYPES PER WEEK,
AND CAPABLE OF A DEADBAND SETTING OF AT LEAST 56F (10'F FOR RESIDENTIAL BETWEEN THE HEATING AND COOLING SETPOINTS. MU CONTROL
SYSTEM SHALL INCLUDE A MICROPROCESSOR AND BE CAPABLE OF RESETTING SU PLY AIR TEMPERATURES BY REPRESENTATIVE BUILDMG LOADS.
14. RECORD DRAWINGS OF THE ACTUAL INSTALLATION SHALL BE PROVIDED TO THE BUILDING OWNER WITHIN 90 DAYS OF THE DATE
OF SYSTEM ACCEPTANCE PER THE WASHINGTON STATE ENERGY CODE. AN OPERATING MANUAL AND MAINTENANCE MANUAL
SHALL BE PROVIDED TO THE BUILDING OWNER. ALL HVAC SYSTEMS SHALL BE BALANCED AND A WRITTEN BALANCING REPORT
SHALL BE PROVIDED TO THE OWNER. HVAC CONTROL SYSTEMS SHALL BE TESTED TO ENSURE THAT THEY OPERATE IN ACCORDANCE
WITH APPROVED PLANS. A PRELIMINARY COMMISSIONING REPORT OF TEST PROCEDURES AND RESULTS SHALL
BE PREPARED PRIOR TO ISSUANCE OF A FINAL CERTIFICATE OF OCCUPANCY. A COMPLETE FINAL COMMISSIONING REPORT OF
TEST PROCEDURES AND RESULTS SHALL BE PROVIDED TO THE OWNER. COMMISSIONING, SYSTEM BALANCING, RECORD DRAWINGS
AS REQUIRED PER THE WASHINGTON STATE ENERGY CODE C408.
15. MECHANICAL SYSTEMS SHALL COMPLY WITH SEISMIC RESTRAINT REQUIREMENTS OF THE BUILDING CODE SMACNA AND ASCE 7. ALL LIFE
SAFETY OR HAZARDOUS MATERIAL RELATED SYSTEMS SHALL BE DEEMED AN Ip=1.5 FOR RESTRAINT MErfHODS OR AS NOTED ON THE DRAWINGS..
REFER TO CODES FOR INSTALLATION REQUIREMENTS AND EXCEPTIONS BASED ON SIZING, WEIGHTS AND MOUNTING HEIGHTS.
16. PROVIDE EARTHQUAKE RESTRAINTS FOR HVAC EQUIPMENT AS REQUIRED BY SMACNA SEISMIC RESTRAINT MANUAL, SEISMIC HAZARD B.
WIRES FOR CEILING SYSTEM ETC. SHALL NOT BE HUNG OFF HVAC EQUIPMENT OR HVAC EQUIPMENT SUPPORTS.
17. PROVIDE FIRE AND COMBINATION FIRE/SMOKE DAMPERS WHERE SHOWN ON PLANS AND WHERE REQUIRED PER CODE.
18. ALL PIPING PENETRATIONS THROUGH RATED ASSEMBLIES SHALL BE SEALED WITH AN UL APPROVED FIRE CAULKING.
19. SMOKE DETECTORS PROVIDING AUTOMATIC SHUTDOWN SHALL BE PROVIDED FOR HVAC EQUIPMENT DELIVERING IN EXCESS OF
2000 CFM [INCLUDING MULTIPLE UNITS DUCTED INTO COMMON DISTRIBUTION OR RETURN, WITH AN AGGREGATE SUPPLY GREATER
THAN 2000 CFM] OR EACH STORY OF RETURN SYSTEMS OVER 15,000 CFM IN A MULTI -STORY INSTALLATION, PER CODE.
SMOKE DETECTORS SHALL BE FIC (ELEC) LINO. POWER -WIRING AND INTERLOCK TO FIRE ALARM SYSTEM BY ELECTRICAL CONTRACTOR AS APPLICABLE.
20. MECHANICAL ACCESS PANELS SHALL BE PROVIDED BY MECHANICAL CONTRACTOR AND INSTALLED BY GENERAL CONTRACTOR.
21. ALL MOTOR STARTERS NOT SHOWN IN EQUIPMENT SCHEDULES SHALL BE FURNISHED AND INSTALLED BY ELECTRICAL CONTRACTOR.
MOTOR EFFICIENCIES TO MEET OR EXCEED CODE MINIMUM.
22. FOR ALL "SEALED AIR TIGHT" SHAFTS OR ROOMS, THE FOLLOWING SHALL OCCUR:
-ALL VERTICAL JOINTS & CORNERS INSIDE THE SHAFT SHALL BE PROVIDED WITH A CONTINUOUS SEAL FOR THE LENGTH OF THE JOINT (BY GC).
-TOP AND BOTTOM WALL TRACKS SHOULD BE CAULKED ALONG THEIR ENTIRE LENGTH (BY GC).
-ANY FLOOR DECKING PERPENDICULAR TO THE SHAFT SHALL BE CAULKED (BY GC). )FILLING WITH ROCK WOOL IS NOT ACCEPTABLE
-USE SECTIONPENETRATIONS
T909.50OFTTHE52012 IBC FOR CMAX ALDOWABLLEKLEAKAGE I AREA, FO'LLOWINGATHEBGUIDELINES FOROTIGHTIDST IR SHAFT COISTRUCTION.
-ALL DOORS SHALL BE PROVIDED WITH TIGHT FITTING GASKETS, AND OPEN AGAINST THE DIRECTION OF ROOM/SHAFT PRESSURE.
23. MAXIMUM LENGTH OF FLEXIBLE DUCT SHALL BE 12 FEET. REFER TO INSTALLATION DETAILS FOR SUPPORT REQUIREMENTS.
FLEXIBLE DUCT FLAME SPREAD RATING SHALL BE < 25 AND SMOKE DEVELOPED RATING SHALL BE < 50. USE FLEXIDUCT
MODEL G -KM FOR LOW AND MEDIUM PRESSURE APPLICATIONS OR APPROVED EQUAL.
24. LOCATION AND DETAILS OF EQUIPMENT DUCT ROUTING, AND CONNECTIONS ARE APPROXIMATE. COORDINATE FINAL LOCATIONS WITH
OTHER TRADES. INSTALL IN ACCORDANCE WITH APPROVED SUBMITTALS AND DETAIL DRAWINGS WHEN APPLICABLE.
25. FOR RESIDENTIAL INSULATION ON DUCTWORK AND PIPING SEE ENERGY CODE CHAPTER R403.
26. ELECTRICAL METERING OF SYSTEMS AS REQUIRED BY ENERGY CODE SECTION C409 IS BY ELECTRICAL. THE ELECTRICAL DESIGN & CONTRACTOR TEAM
WILL FURNISH THE NECESSARY ELECTRICAL DISTRIBUTION AND METERING COMPONENTS - SEE ELECTRICAL DRAWINGS. THE MECHANICAL CONTRACTOR
WILL FURNISH A BUILDING MANAGEMENT SYSTEM CAPABLE OF COLLECTING AND STORING THE INFORMATION. A PERMANENT AND VISIBLE DISPLAY IS
TO BE PROVIDED FOR EACH BUILDING, READILY ACCESSIBLE TO OPERATION AND MANAGEMENT PERSONNEL
DEMO DUCTfWORK
LAST UPDATED
WALL-MOUINTED GRILLE
oo
PIPE ELBOIW UP
INSULATION
R -VALUE
PIPE ELBOW DN
SUPPLY & RETURN
DIRECTION OF FLOW
R-8
DIRECTION OF SLOPE DOWN
OUTSIDE AIR
WITHIN CONDITIONED SPACE, INSIDE BUILDING
PLUG OR (CAP
--®--�
PRESS REO)WCING ASSEMBLY
���----i
SOLENOID 'VALVE
1,2
PUMP
�-CHWS /CHWR-s
CHILLED WIATER SUPPLY/RETURN
�- RL/RS---s
REFRIGERANT LIQUID/SUCTION
�- NG --s
NATURAL GAS
z - LPG -s
LIQUID PROPANE GAS
Z--CDWS /CDWR-s
CONDENSER WATER SUPPLY/RETURN
HWS/HWR-s
HEATING WATER SUPPLY/RETURN
Z--- COND -4
CONDENSATiE
r- FOV -s
FUEL OIL (VENT
Z-- FOS / FOR -s
FUEL OIL :SUPPLY/RETURN
2-- RDG -5
REFRIGERANT DISCHARGE GAS
MECHANICAL GENERAL NOTES
1. WORK SHALL CONFORM TO APPLICABLE CODES AND REGULATIONS, INCLUDING, BUT NOT LIMITED TO THE 2012 IBC, 2012 WSEC, & 2)12 IMC.
2. DIMENSIONS ARE TO FACE OF STUD, CONCRETE, OR MASONRY UNLESS NOTED OTHERWISE.
3. DO NOT SCALE DRAWINGS. DIMENSIONS GOVERN.
4. VERIFY EXISTING CONDITIONS, DIMENSIONS, DETAILS, ETC. NOTIFY ENGINEER OF ANY DISCREPANCIES PRIOR TO PROCEEDING WITH WORC
5. WHEN CONSTRUCTION DETAILS ARE NOT SHOWN OR NOTED FOR ANY PART OF THE WORK, DETAILS SHALL BE THE SAME
AS FOR OTHER SIMILAR WORK. IF ADDITIONAL QUESTIONS REMAIN, CONTACT THE ENGINEER PRIOR TO PROCEEDING.
6. ALL STRUCTURAL OPENINGS AND PLATFORMS SHALL BE PROVIDED BY THE GENERAL CONTRACTOR UNLESS NOTED OTHERWISE.
7. DUCT SEALING AND CONSTRUCTION TO MEET SMACNA AND ENERGY CODE REQUIREMENTS. UNLESS OTHERWISE NOTED, LOW PRESSURE DUCTWORK
(DOWNSTREAM OF VAV BOXES, CONSTANT VOLUME AC SYSTEMS, TOILET EXHAUSTS, ETC. TO MEET 2" CONSTRUCTION STANDARDS WITH
SEAL CLASS C. MEDIUM PRESSURE DUCTWORK (UPSTREAM OF VAV BOXES, HIGH VELOCITY EXHAUSTS, ETC.) TO MEET 4" CONSTRUCTION STANDARDS
WITH SEAL CLASS A. DUCT RISERS IN SHAFTS WITH DAMPERED PENETRATIONS TO MEET 6" CONSTRUCTION STANDARDS WITH SEAL CLkSS A.
8. ALL CEILING DIFFUSERS ARE 4 -WAY THROW UNLESS NOTED OTHERWISE.
9. ALL DUCT DIMENSIONS ARE CLEAR INSIDE DIMENSIONS AFTER LINING HAS BEEN ACCOUNTED FOR.
10. OUTSIDE AIR INTAKES ON ALL AIR HANDLING UNITS SHALL BE 10 FEET AWAY FROM ANY FUEL BURNING EQUIPMENT OR 3 FEET BELOV
ANY PLUMBING VENT OR EXHAUST OUTLET WITHIN 10 FEET
11. ALL AIR ECONOMIZERS SHALL BE CAPABLE OF THE FOLLOWING:
-0% TO 100% OF THE DESIGN SUPPLY AIR
-CONTROLLED BY A CONTROL SYSTEM DETERMINING IF THE OUTSIDE AIR CAN MEET PART OR ALL OF THE BUILDING COOLING LOADS.
-INTEGRATED TO PROVIDE PARTIAL COOLING EVEN WHEN MECHANICAL COOLING IS REQUIRED.
12. OUTSIDE AIR INTAKE,RELIEF, AND EXHAUST OPENINGS SHALL BE EQUIPPED WITH MOTORIZED (OR GRAVITY DAMPERS PER
EXCEPTIONS IN C403.2.4.4) WHICH CLOSE AUTOMATICALLY WHEN SYSTEM IS OFF OR UPON POWER FAILURE.
13. THE CONTROL SYSTEM SHALL BE 7 -DAY PROGRAMMABLE, CAPABLE OF BEING SET FOR SEVEN (7) DIFFERENT DAY TYPES PER WEEK,
AND CAPABLE OF A DEADBAND SETTING OF AT LEAST 56F (10'F FOR RESIDENTIAL BETWEEN THE HEATING AND COOLING SETPOINTS. MU CONTROL
SYSTEM SHALL INCLUDE A MICROPROCESSOR AND BE CAPABLE OF RESETTING SU PLY AIR TEMPERATURES BY REPRESENTATIVE BUILDMG LOADS.
14. RECORD DRAWINGS OF THE ACTUAL INSTALLATION SHALL BE PROVIDED TO THE BUILDING OWNER WITHIN 90 DAYS OF THE DATE
OF SYSTEM ACCEPTANCE PER THE WASHINGTON STATE ENERGY CODE. AN OPERATING MANUAL AND MAINTENANCE MANUAL
SHALL BE PROVIDED TO THE BUILDING OWNER. ALL HVAC SYSTEMS SHALL BE BALANCED AND A WRITTEN BALANCING REPORT
SHALL BE PROVIDED TO THE OWNER. HVAC CONTROL SYSTEMS SHALL BE TESTED TO ENSURE THAT THEY OPERATE IN ACCORDANCE
WITH APPROVED PLANS. A PRELIMINARY COMMISSIONING REPORT OF TEST PROCEDURES AND RESULTS SHALL
BE PREPARED PRIOR TO ISSUANCE OF A FINAL CERTIFICATE OF OCCUPANCY. A COMPLETE FINAL COMMISSIONING REPORT OF
TEST PROCEDURES AND RESULTS SHALL BE PROVIDED TO THE OWNER. COMMISSIONING, SYSTEM BALANCING, RECORD DRAWINGS
AS REQUIRED PER THE WASHINGTON STATE ENERGY CODE C408.
15. MECHANICAL SYSTEMS SHALL COMPLY WITH SEISMIC RESTRAINT REQUIREMENTS OF THE BUILDING CODE SMACNA AND ASCE 7. ALL LIFE
SAFETY OR HAZARDOUS MATERIAL RELATED SYSTEMS SHALL BE DEEMED AN Ip=1.5 FOR RESTRAINT MErfHODS OR AS NOTED ON THE DRAWINGS..
REFER TO CODES FOR INSTALLATION REQUIREMENTS AND EXCEPTIONS BASED ON SIZING, WEIGHTS AND MOUNTING HEIGHTS.
16. PROVIDE EARTHQUAKE RESTRAINTS FOR HVAC EQUIPMENT AS REQUIRED BY SMACNA SEISMIC RESTRAINT MANUAL, SEISMIC HAZARD B.
WIRES FOR CEILING SYSTEM ETC. SHALL NOT BE HUNG OFF HVAC EQUIPMENT OR HVAC EQUIPMENT SUPPORTS.
17. PROVIDE FIRE AND COMBINATION FIRE/SMOKE DAMPERS WHERE SHOWN ON PLANS AND WHERE REQUIRED PER CODE.
18. ALL PIPING PENETRATIONS THROUGH RATED ASSEMBLIES SHALL BE SEALED WITH AN UL APPROVED FIRE CAULKING.
19. SMOKE DETECTORS PROVIDING AUTOMATIC SHUTDOWN SHALL BE PROVIDED FOR HVAC EQUIPMENT DELIVERING IN EXCESS OF
2000 CFM [INCLUDING MULTIPLE UNITS DUCTED INTO COMMON DISTRIBUTION OR RETURN, WITH AN AGGREGATE SUPPLY GREATER
THAN 2000 CFM] OR EACH STORY OF RETURN SYSTEMS OVER 15,000 CFM IN A MULTI -STORY INSTALLATION, PER CODE.
SMOKE DETECTORS SHALL BE FIC (ELEC) LINO. POWER -WIRING AND INTERLOCK TO FIRE ALARM SYSTEM BY ELECTRICAL CONTRACTOR AS APPLICABLE.
20. MECHANICAL ACCESS PANELS SHALL BE PROVIDED BY MECHANICAL CONTRACTOR AND INSTALLED BY GENERAL CONTRACTOR.
21. ALL MOTOR STARTERS NOT SHOWN IN EQUIPMENT SCHEDULES SHALL BE FURNISHED AND INSTALLED BY ELECTRICAL CONTRACTOR.
MOTOR EFFICIENCIES TO MEET OR EXCEED CODE MINIMUM.
22. FOR ALL "SEALED AIR TIGHT" SHAFTS OR ROOMS, THE FOLLOWING SHALL OCCUR:
-ALL VERTICAL JOINTS & CORNERS INSIDE THE SHAFT SHALL BE PROVIDED WITH A CONTINUOUS SEAL FOR THE LENGTH OF THE JOINT (BY GC).
-TOP AND BOTTOM WALL TRACKS SHOULD BE CAULKED ALONG THEIR ENTIRE LENGTH (BY GC).
-ANY FLOOR DECKING PERPENDICULAR TO THE SHAFT SHALL BE CAULKED (BY GC). )FILLING WITH ROCK WOOL IS NOT ACCEPTABLE
-USE SECTIONPENETRATIONS
T909.50OFTTHE52012 IBC FOR CMAX ALDOWABLLEKLEAKAGE I AREA, FO'LLOWINGATHEBGUIDELINES FOROTIGHTIDST IR SHAFT COISTRUCTION.
-ALL DOORS SHALL BE PROVIDED WITH TIGHT FITTING GASKETS, AND OPEN AGAINST THE DIRECTION OF ROOM/SHAFT PRESSURE.
23. MAXIMUM LENGTH OF FLEXIBLE DUCT SHALL BE 12 FEET. REFER TO INSTALLATION DETAILS FOR SUPPORT REQUIREMENTS.
FLEXIBLE DUCT FLAME SPREAD RATING SHALL BE < 25 AND SMOKE DEVELOPED RATING SHALL BE < 50. USE FLEXIDUCT
MODEL G -KM FOR LOW AND MEDIUM PRESSURE APPLICATIONS OR APPROVED EQUAL.
24. LOCATION AND DETAILS OF EQUIPMENT DUCT ROUTING, AND CONNECTIONS ARE APPROXIMATE. COORDINATE FINAL LOCATIONS WITH
OTHER TRADES. INSTALL IN ACCORDANCE WITH APPROVED SUBMITTALS AND DETAIL DRAWINGS WHEN APPLICABLE.
25. FOR RESIDENTIAL INSULATION ON DUCTWORK AND PIPING SEE ENERGY CODE CHAPTER R403.
26. ELECTRICAL METERING OF SYSTEMS AS REQUIRED BY ENERGY CODE SECTION C409 IS BY ELECTRICAL. THE ELECTRICAL DESIGN & CONTRACTOR TEAM
WILL FURNISH THE NECESSARY ELECTRICAL DISTRIBUTION AND METERING COMPONENTS - SEE ELECTRICAL DRAWINGS. THE MECHANICAL CONTRACTOR
WILL FURNISH A BUILDING MANAGEMENT SYSTEM CAPABLE OF COLLECTING AND STORING THE INFORMATION. A PERMANENT AND VISIBLE DISPLAY IS
TO BE PROVIDED FOR EACH BUILDING, READILY ACCESSIBLE TO OPERATION AND MANAGEMENT PERSONNEL
1 REFER TO ENERGY CODE SECTION C403.2.7 FOR FURTHER REQUIREMENTS
2 INSULATED COOLED DUCTS REQUIRED A VAPOR RETARDER (PERM < 0.5) AND SEALED JOINTS
3 WEATHERPROOF BARRIER REQUIRED AROUND DUCTWORK TO MAINTAIN WATER TIGHTNESS
4 INSULATE OUTSIDE AIR DUCTS TO BUILDING EXTERIOR WALL LEVEL PER ENERGY CODE SECTION: C403.2.7.1 UNTIL
CONNECTED TO EQUIPMENT SERVED OR TO THE CODE REQUIRED SHUTOFF DAMPER (THEN R-6 FOR REST OF
INSTALLATION) OR HEATING & COOLING EQUIPMENT
5 R-7 CAN BE USED IN LIEU OF BUILDING ENVELOPE INSULATION LEVEL IF:
DEDICATED OUTSIDE AIR SYSTEM AND LESS THAN 2,800 CFM SUPPLY AIR
RECEIVED
CITY OF TUKWILA
MAR 0 8 2016
PERMIT CENTER
MINIMUMI INSULATION LAST UPDATED: 01/10/14
MINIMUM INSULATION
LAST UPDATED
01/10/14
DUCT TYPE
DUCT LOCATION IN HEATED AND MECHANICALLY COOLED DUCT SYSTEM
INSULATION
R -VALUE
REMARKS
SUPPLY & RETURN
NOT WITHIN CONDITIONED SPACE, OUTSIDE BUILDING
R-8
1,2,3
OUTSIDE AIR
WITHIN CONDITIONED SPACE, INSIDE BUILDING
SEE NOTES 4 & 5
1,2,3,4,5
SUPPLY & RETURN
NOT WITHIN CONDITIONED SPACE: INSIDE BUILDING
R-6
1,2
SUPPLY AIR
<550 OR >1050
WITHIN CONDITIONED SPACE
t R-3.3
1,2
1 REFER TO ENERGY CODE SECTION C403.2.7 FOR FURTHER REQUIREMENTS
2 INSULATED COOLED DUCTS REQUIRED A VAPOR RETARDER (PERM < 0.5) AND SEALED JOINTS
3 WEATHERPROOF BARRIER REQUIRED AROUND DUCTWORK TO MAINTAIN WATER TIGHTNESS
4 INSULATE OUTSIDE AIR DUCTS TO BUILDING EXTERIOR WALL LEVEL PER ENERGY CODE SECTION: C403.2.7.1 UNTIL
CONNECTED TO EQUIPMENT SERVED OR TO THE CODE REQUIRED SHUTOFF DAMPER (THEN R-6 FOR REST OF
INSTALLATION) OR HEATING & COOLING EQUIPMENT
5 R-7 CAN BE USED IN LIEU OF BUILDING ENVELOPE INSULATION LEVEL IF:
DEDICATED OUTSIDE AIR SYSTEM AND LESS THAN 2,800 CFM SUPPLY AIR
RECEIVED
CITY OF TUKWILA
MAR 0 8 2016
PERMIT CENTER
MINIMUMI INSULATION LAST UPDATED: 01/10/14
FLUID DESIGN
INSULATION CONDUCTIVITY
NOMINAL PIPE DIAMETER (INCH)
OPERATING
TEMP °F
CONDUCTIVITY
RANGE
MEAN TEMP
RATING °F
<1
1 TO
<1-1/2
1-1/2 TO
<4
4 TO
<8
>8
HEATING SYSTEMS (STEAM, CONDENSATE, HYDRONIC HOT WATER, DOMESTIC HOT WATER)
>350 0.32-0.34 250 4.5 5.0 5.0 5.0 5.0
251-350 0.29-0.32 200 3.0 4.0 4.5 4.5 4.5
201-250 0.27-0.30 150 2.5 2.5 2.5 3.0 3.0
141-200 0.25-0.29 125 1.5 1.5 2.0 2.0 2.0
105-140 0.21-0.28 100 1.0 1.0 1.5 1.5 1.5
DOMESTIC COLD WATER AND HORIZONTAL RAIN LEADERS TO FIRST VERTICAL RAIN LEADER
40-60 1 0.21-0.27 75 1 as 7 0.5 1 1.0 1.0 1.0
COOLING SYSTEMS (CHILLED WATER, BRINE AND REFRIGERANT, WATERSIDE ECONOMIZER SYSTEMS)**
40-60
0.21-0.27
75
0.5
1 0.5
1.0
1.0
1.0
<40
0.20-0.26
75
1 0.5
1 1.0
1 1.0
1.0
1.5
NOT REQUIRED FOR STRAINERS, CONTROL VALVES & BALANCING VALVES ASSOCIATED WITH PIPING 1" OR LESS IN DIA.
** TYPICAL CONDENSER WATER PIPE IN NON -ECONOMIZER SYSTEMS DOES NOT REQUIRE INSULATION
REVISIONS
No than, ^ 5h?Il he, rn.,7do to the scope
0 �^1orl< withct.,t prior e ;proval of
Tukwila Building Division.
NOTE: Revisions will require n newi p!�:n submittal
and may include additional p!c.n reviavr fees.
APN NUMBER
2623049063
LEGAL DESCRIPTION
LOT 1 OF CITY OF TUKWILA SHORT PLAT NO 80 -45 -SS RECORDING NO
8106040707 SD PLAT DAF - POR NE 1/4 OF SW 1/4 LY WLY OF
SOUTHCENTER PARKWAY & LY ELY OF INTERSTATE HWY 5 - COMM NE COR
OF NE 1/4 OF SW 1/4 TH N 88-05-42 W 701.10 FT TO WLY MGN SD
SOUTHCENTER PARKWAY TH ALG SD WLY MGN S 01-08-45 W 10.65 FT TH S
01-05-23 W 1305.71 FT TO INTSN WITH S LN OF NE 1/4 OF SW 1/4 TH N
87-55-53 W 621.98 FT TO SW COR OF NE 1/4 OF SW 1/4 TO TPOB TH' N
00-50-36 E 255 FT TH S 87-55-53 E 623.07 FT TAP ON SD WLY MGN OF
SOUTHCENTER PARKWAY TH S 01-05-23 W 254.98 FT TO S LN SD SUBD TH
N 87-55-53 W 621.98 FT TO TPOB
VICINITY MAP
NO SCALE
o�
SITE ---MAP Qy
NO MALE
Pinch: nicat
..ffElsstricat
.0• Plumbing
0106as Piping
City of Tukwila
t.iF' Oi1/( ICON
ISSUE FOR PERMIT
Hermanson Company LLP
1221 2nd Avenue North
Kent, Washington 98032
Tel: (206) 575-9700
Fax: (206) 575-9800
www.hermanson.com
Contractor Reg #: HERMACLO05BJ
URGENT CARE
TUKWILA PRECOR
17275 SOUTHCENTER PARKWAY
TUKWILA, WA 98188
FILE COPY
r
a��i lij✓teY:Y Y (v.� , .I I1.Y i 1 ....� tr.J [ . .......1 '
Oy:
Date•
Revisions
02/26/16 JMH ISSUE FOR PERMIT
No. Date By Description
Design Team
Design JMH
Drawn FVP
Checked MIG
Scale AS NOTED
Drawing Number C-0589-08037
Project Number 11-16-08037
Issue Date 02/24/16
LEGEND, ABBREVIATIONS,
GENERAL NOTES & SHEET
N D EX- ��D FCS
CODE COMPLIANCE
CODE
APPROVED
N MAR 2 5 2016' -
City ofTLikwila
BUILDING DIVISION
DRAWING INDEX
SHEET NO.
SHEET TITLE CURRENT
REVISION
M0.00
LEGEND ABBREVIATIONS GENERAL NOTES & SHEET INDEX - HVAC
M0.01
SCHEDULES SHEET - HVAC
M2.01
PARTIAL 1ST FLOOR PLAN - HVAC
M2.R1
PARTIAL ROOF PLAN - HVAC
REVISIONS
No than, ^ 5h?Il he, rn.,7do to the scope
0 �^1orl< withct.,t prior e ;proval of
Tukwila Building Division.
NOTE: Revisions will require n newi p!�:n submittal
and may include additional p!c.n reviavr fees.
APN NUMBER
2623049063
LEGAL DESCRIPTION
LOT 1 OF CITY OF TUKWILA SHORT PLAT NO 80 -45 -SS RECORDING NO
8106040707 SD PLAT DAF - POR NE 1/4 OF SW 1/4 LY WLY OF
SOUTHCENTER PARKWAY & LY ELY OF INTERSTATE HWY 5 - COMM NE COR
OF NE 1/4 OF SW 1/4 TH N 88-05-42 W 701.10 FT TO WLY MGN SD
SOUTHCENTER PARKWAY TH ALG SD WLY MGN S 01-08-45 W 10.65 FT TH S
01-05-23 W 1305.71 FT TO INTSN WITH S LN OF NE 1/4 OF SW 1/4 TH N
87-55-53 W 621.98 FT TO SW COR OF NE 1/4 OF SW 1/4 TO TPOB TH' N
00-50-36 E 255 FT TH S 87-55-53 E 623.07 FT TAP ON SD WLY MGN OF
SOUTHCENTER PARKWAY TH S 01-05-23 W 254.98 FT TO S LN SD SUBD TH
N 87-55-53 W 621.98 FT TO TPOB
VICINITY MAP
NO SCALE
o�
SITE ---MAP Qy
NO MALE
Pinch: nicat
..ffElsstricat
.0• Plumbing
0106as Piping
City of Tukwila
t.iF' Oi1/( ICON
ISSUE FOR PERMIT
Hermanson Company LLP
1221 2nd Avenue North
Kent, Washington 98032
Tel: (206) 575-9700
Fax: (206) 575-9800
www.hermanson.com
Contractor Reg #: HERMACLO05BJ
URGENT CARE
TUKWILA PRECOR
17275 SOUTHCENTER PARKWAY
TUKWILA, WA 98188
FILE COPY
r
a��i lij✓teY:Y Y (v.� , .I I1.Y i 1 ....� tr.J [ . .......1 '
Oy:
Date•
Revisions
02/26/16 JMH ISSUE FOR PERMIT
No. Date By Description
Design Team
Design JMH
Drawn FVP
Checked MIG
Scale AS NOTED
Drawing Number C-0589-08037
Project Number 11-16-08037
Issue Date 02/24/16
LEGEND, ABBREVIATIONS,
GENERAL NOTES & SHEET
N D EX- ��D FCS
CODE COMPLIANCE
CODE
APPROVED
N MAR 2 5 2016' -
City ofTLikwila
BUILDING DIVISION
EXISTING GAS PACKAGED ROOFTOP UNIT SCHEDULE 02/25/16
UNIT
TAG LOCATION SERVES
BASIS OF
DESIGN
ESP
SUPPLY IN
CFM WG SEER/EER
COOLING CAPACITY
GAS HEATING CAPACITY
LAST UPDATED;
SOUND OPERATING
ELEC PER ARI 270/370 WEIGHT
MCA MAX FUSE / PH (Dba) (LBS REMARKS
TOTAL
MBH
SENS
MBH
INPUT
MBH
OUTPUT
MBH
AFUENG
CONN
RTU -1 ROOF (URGENT CARE
TRANE YSC0060A4RLA-D1
2000 1.00 10.2
63
48
60
48
80
1/2
16.3 25 460/3 82 741 1
RTU -2 ROOF (URGENT CARE
TRANE YSC0060A4RLA-D1
1 2 000 1.00 10.2
63
48
1 60
48
1 80
1 1/2
16.3 25 460/3 82 741 1 1
REMARKS:
1 UNIT IS EXISTING ,AND SCHEDULE IS PROVIDED FOR REFERENCE ONLY
REMARKS:
1 ELECTRICAL CONTE RACTOR TO PROVIDE SCCR PROTECTION FOR EQUIPMENT AS REQUIRED BY NATIONAL ELECTRICAL CODE.
MANUFACTURER ITO PROVIDE SCCR LISTING (5 KAIC MINIMUM) INSIDE CONTROL PANEL AS REQUIRED BY NATIONAL ELECTRICAL CODE.
2 ELECTRICAL DISC(DNNECT AND MOTOR STARTER (AS REQUIRED) BY ELECTRICAL CONTRACTOR
3 FAN TO OPERATE DURING BUILDING OCCUPIED HOURS THROUGH BUILDING EMS BY CONTROLS CONTRACTOR
4 MOTOR TO BE ECM (OR 70% MINIMUM EFFICIENCY) PER ENERGY CODE C403.2.10.3 FOR MOTORS GREATER OR EQUAL TO 1/12 HP & LESS THAN 1 HP
5 CONTRACTOR TO VERIFY AND PROVIDE ALL EQUIPMENT REQUIRED BY MANUFACTURER
6 FOR TRADE COORUMNATION REFER TO APPROVED EQUIPMENT SUBMITTALS
7 INSTALL PER MANIUFACTURER RECOMMENDATION
8 FIELD COORDINAITE EXACT UNIT LOCATION
TRANSFER
RETURN
/
FAN SCHEDULE
AIR
GRILLE
LAST UPDATED;
02/08/ J 6
UNIT
TAG LOCATION
AREA
SERVED
BASIS OF
DESIGN
MOUNTING
TYPE LOCATION CFM
ESP MOTOR
IN WG BHP HP/W
SYSTEM ELECT
VFD DAMPER V/PH
SOUND WEIGHT
SONES LBS
REMARKS
EFR-01 ROOF
TOILETS
G'HECK G -085 -VG
ROOF CAP CURB 220
0.5 0.06 1/10
ECM - 115/1
7 28
1-8
EFR-02 ROOF
TOILETS
G'HECK G -085 -VG
ROOF CAP CURB 140
0.5 0.04 1/10
ECM - 115/1
7 28
1-8
REMARKS:
1 ELECTRICAL CONTE RACTOR TO PROVIDE SCCR PROTECTION FOR EQUIPMENT AS REQUIRED BY NATIONAL ELECTRICAL CODE.
MANUFACTURER ITO PROVIDE SCCR LISTING (5 KAIC MINIMUM) INSIDE CONTROL PANEL AS REQUIRED BY NATIONAL ELECTRICAL CODE.
2 ELECTRICAL DISC(DNNECT AND MOTOR STARTER (AS REQUIRED) BY ELECTRICAL CONTRACTOR
3 FAN TO OPERATE DURING BUILDING OCCUPIED HOURS THROUGH BUILDING EMS BY CONTROLS CONTRACTOR
4 MOTOR TO BE ECM (OR 70% MINIMUM EFFICIENCY) PER ENERGY CODE C403.2.10.3 FOR MOTORS GREATER OR EQUAL TO 1/12 HP & LESS THAN 1 HP
5 CONTRACTOR TO VERIFY AND PROVIDE ALL EQUIPMENT REQUIRED BY MANUFACTURER
6 FOR TRADE COORUMNATION REFER TO APPROVED EQUIPMENT SUBMITTALS
7 INSTALL PER MANIUFACTURER RECOMMENDATION
8 FIELD COORDINAITE EXACT UNIT LOCATION
TRANSFER
RETURN
/
EXHAUST
AIR
GRILLE
SCHEDULE
TYPE
NECK SIZE
:N DIA
MAX
CFM
CORE
SIZE
FACE
SIZE NC
MOUNTING
LAST UPDATED:
2/25/2016
UNIT
TAG
BASIS OF
DESIGN
MAX NECK SIZE
CFM IN DIA MOUNTING
FACE
SIZE
MATERIAL
REMARKS
EC1
PRICE 80 TB
500
-- --
T -BAR
24x 12
ALUMINUM
2 9 10
EC2
PRICE 80 TB
1,000
-- --
T -BAR
24 x 24
ALUMINUM
2, 9, 10
EC3 I
PRICE 80 TB
2,00
-- --
T -BAR
24 x 48
ALUMINUM
2 9 10
EC4
PRICE 80 F
500
-- --
SURFACE MOUNT
24 x 12
ALUMINUM
2 3 9 10,12
EC5
PRICE 80 F
1,000
-- --
SURFACE MOUNT
- 24 x 24
ALUMINUM
2 3 9 10,12
EC6
PRICE 80 F
2,000
-- --
SURFACE MOUNT
24 x 48
ALUMINUM
2 3 9 10 12
Rl
PRICE 80 TB
110
6
T -BAR
24 x 12
ALUMINUM
1,5,7/8,9
R2
PRICE 80 TB
230
8
T -BAR
24x 12
ALUMINUM
1,5,7/8,9
R3
PRICE 80 TB
350
10
T -BAR
24 x 12
ALUMINUM
1,5,7/8,9
R4
PRICE 80 TB
600
12
T -BAR
24 x 12
ALUMINUM
1,5,7/8,9
R5
PRICE 80 TB
900
14
T -BAR
24 x 24
ALUMINUM
1,5,7/8,9
R6
PRICE 80 TB
1,200
16
T -BAR
24 x 24
ALUMINUM
1,5,7/8,9
R7 I
PRICE 80 TB
1,600
18
T -BAR
24 x 24
ALUMINUM
1,5,7/8,9
R8
PRICE 80 TB
2,400
20
T -BAR
24 x 48
ALUMINUM
1,5,7/8,9
R9
PRICE 80 TB
3,000
22
T -BAR
24 x 48
ALUMINUM
1,5,7/8,9
R10
PRICE 80 TB
3,200
24
T -BAR
24 x 48
ALUMINUM
1,3,7/8,9
G1
PRICE 630DF
150
-- --
GWB
8 x 8
STEEL
3,6,7/8,9, 12
G2 I
PRICE 630DF
250
-- --
GWB
lox 10
STEEL
3 6 7/8 9,12
G3
PRICE 630DF
375
-- --
GWB
12 x 12
STEEL
3 6 7/8 9,12
G4
PRICE 630DF
525
-- --
GWB
14 x 14
STEEL
3,6,7/8,9, 12
G5
PRICE 630DF
600
-- --
GWB
16 x 16
STEEL
3,6,7/8,9, 12
G6
PRICE 630DF
900
-- --
GWB
18 x 18
STEEL
3,6,7/8,9, 12
G7 I
PRICE 630DF
1,200
-- --
GWB
24 x 24
STEEL
3,6,7/8,9, 12
G8
PRICE 630DF
2,400
-- --
GWB
24 x 48
STEEL
3,6,7/8,9, 12
G9
PRICE 630DF
150
8
GWB
8 x 8
STEEL
1 3 6 7/8 9 12
G10
PRICE 630DF
250
10
GWB
lox 10
STEEL
1 3 6 7/8 9,12
G11
PRICE 630DF
375
12
GWB
12 x 12
STEEL
1 3 6 7/8 9 12
G12
PRICE 630DF
525
14
GWB
14 x 14
STEEL
1 3 6 7/8 9,12
G13
PRICE 630DF
600
14
GWB
16 x 16
STEEL
1, 3, 6, 7/8 9, 12
G14
PRICE 630DF
900
16
GWB
18 x 18
STEEL
1 3 6 7/8 9 12
G15
PRICE 630DF
1,200
16
GWB
24 x 24
STEEL
1 3 6 7/8, 9,12
G16
PRICE 630DF
2,400
20
GWB
24 x 48
STEEL
1, 3, 6 7/8, 9,12
T1
PRICE 630F
150
-- --
GWB
8 x 8
STEEL
3,7/8,9, 12
T2
PRICE 630F
250
-- --
GWB
10 x 10
STEEL
3,7/8,9, 12
T3
PRICE 630F
375
-- --
GWB
12 x 12
STEEL
3,7/8,9, 12
T4
PRICE 630F
525
-- --
GWB
14 x 14
STEEL
3,7/8,9, 12
T5
PRICE 630F
600
-- --
GWB
16 x 16
STEEL
3,7/8,9,12
T6
PRICE 630F
900
-- --
GWB
18 x 18
STEEL
3,7/8,9,12
T7
PRICE 630F
1,20
-- --
GWB
24 x 24
STEEL
3,7/8,9,12
T8
PRICE 630F
2,400
-- --
GWB
24 x 48
STEEL
3,7/8,9,12
T9
PRICE 630F
150
8
GWB
8 x 8
STEEL
1,3,7/8,9, 12
T10
PRICE 630F
250
10
GWB
lox 10
STEEL
1 3 7/8 9 12
Tll
PRICE 630F
375
12
GWB
12 x 12
STEEL
1 3 7/8 9 12
T12
PRICE 630F
525
14
GWB
14 x 14
STEEL
1 3 7/8, 9 12
T13
PRICE 630F
600
14
GWB
16 x 16
STEEL
1, 3, 7/8, 9, 12
T14
PRICE 630F
900
16
GWB
18 x 18
STEEL
1 1 3 7/8, 9 12
T15
PRICE 630F
1,200
16
GWB
24 x 24
STEEL
1 3 7/8 9 12
T16
PRICE 630F
2,400
20
GWB
24 x 48
STEEL
1, 3, 7/8, 9, 12, 12
REMARKS:
1 RUNOUT SAME AS D)WG NECK SIZE U.N.O. ON DWG
2 CORE ONLY - LAY-INI
3 SURFACE MOUNT FRAME
4 CHANNEL FRAME - UAY-IN
5 T -BAR LAY -IN
6 PROVIDE OPPOSED 03LADE DAMPER (OBD)
7 PROVIDE DUCTBOARD PLENUM
8 PROVIDE SHEETMET-AL PLENUM
9 STANDARD #26 WHITE FINISH
10 PROVIDE ALUMINUM( GRILLES IN SHOWERS/HUMID AREAS
11 ALL NON-FERROUS MATERIALS IN MRI ROOMS
12 WHERE VOLUME DAMPERS ARE NOT ACCESSIBLE, PROVIDE HAND HOLE ACCESS OR YOUNGS REGULATOR WITH CEILING PLATE
OR DURODYNE CABLE OPERATED DAMPER WITH CABLE ROUTED INSIDE DUCT & ADJUSTMENT THROUGH GRILLE FACE
REMARKS:
1 RUN OUT SIZE SAME SIZE AS DIFFUSERNECK SIZE, U.N.O. ON DWGS.
2 ALL DIFFUSERS TO HAVE SIDE INLET SFEET METAL CAN PLENUM IF < 1.5 DIA STRAIGHT FLEX AVAILABLE FOR TOP INLET
3 ECCO MFG DIFFUSER CAN TO HAVE PERFORATED INTERIOR PLATE (AND 1" SOUNDLINING IF SPACE <- NC -30 OR SAT < 55°F)
4 STANDARD WHITE POWDER COAT
5 PROVIDE FRAME 3P, LAY -IN TYPE.
6 PROVIDE SURFACE MOUNTING FRAME MODEL SMF FOR GRILLE REMOVAL & INSTALLATION IN HARD LID CEILING
7 WHERE VOLUME DAMPERS ARE NOT ACCESSIBLE, PROVIDE HAND HOLE ACCESS OR YOUNGS REGULATOR WITH CEILING PLATE
OR DURODYNE CABLE OPERATED DAMPER WITH CABLE ROUTED INSIDE DUCT & ADJUSTMENT THROUGH GRILLE FACE
RECEIVED
CITY OF TUKWILA
MAR 0 8 2016
PERMIT CENTER
Hermanson Company LLP
1221 2nd Avenue North
Kent, Washington 98032
Tel: (206) 575-9700
Fax: (206) 575-9800
www.hermanson.com
Contractor Reg #: HERMACLO05BJ
URGENT CARE
TUKWILA PRECOR
17275 SOUTHCENTER PARKWAY
TUKWILA, WA 98188
Revisions
_
02/26/16 JMH ISSUE FOR PERMIT
No. Date By Description
Design Team
Design JMH
Drawn
FVP
Checked MIG
Scale
AS NOTED
Drawing Number C-0589-08037
Project Number 11-16-08037
Issue Date 02/24/16
SCHEDULE SHEET
Hv s` -REVIEWED OR
CODE COMPLIAW
APPROVED
MAR 2 5 2116
City Of Tukwila
BUILDING DIVISION
MODULAR DIFFUSER
SCHEDULE
LAST UPDATED:
02/25/16
UNIT
TAG
BASIS OF
DESIGN
TYPE
NECK SIZE
:N DIA
MAX
CFM
CORE
SIZE
FACE
SIZE NC
MOUNTING
MATERIAL
REMARKS
DT1
PRICE SMCD/3P
MODULAR
6
110
6 X 6
24 X 24
T -BAR
STEEL
1,2,3,4,5
DT2
PRICE SMCD/3P
MODULAR
8
230
8 X 8
24 X 24
T -BAR
STEEL
1,2,3 4,5
DT3
PRICE SMCD 3P
MODULAR
10
350
10 X 10
24 X 24
T -BAR
STEEL
1,2,3,4,5
DT4
PRICE SMCD/3P
MODULAR
12
500
12 X 12
24 X 24
T -BAR
STEEL
1,2,3,4,5
DT5
PRICE SMCD 3P
MODULAR
12
600
14X 14
24 X 24
T -BAR
STEEL
1,2,3,4,5
DT6
PRICE SMCD/3P
MODULAR
14
880
16 X 16
24 X 24
T -BAR
STEEL
1 2 3 4 5
DT7
PRICE SMCD/3P
MODULAR
16
1,120
18 X 18
24 X 24
T -BAR
STEEL
1,2,3,4,5
DG1
PRICE SMCD 6
MODULAR
6
110
6 X 6
-- --
SURFACE
STEEL
1,2,3,4,5,6,7
DG2
PRICE SMCD/6
MODULAR
8
230
8 X 8
-- --
SURFACE
STEEL
1,2,3,4,5,6,7
DG3
PRICE SMCD 6
MODULAR
10
350
lox 10
-- --
SURFACE
STEEL
1,2,3,4,5,6,7
DG4
PRICE SMCD 6
MODULAR
12
500
12 X 12
- --
SURFACE
STEEL
1,2,3,4,5,6,7
DG5
PRICE SMCD/6
MODULAR
12
600
14 X 14
-- --
SURFACE
STEEL
1,2,3,4 5,6,7
DG6
PRICE SMCD/6
MODULAR
14
880
16 X 16
- --
SURFACE
STEEL
1,2,3,4,5,6,7
DG7
PRICE SMCD/6
MODULAR
16
1,120
18 X 18
- --
SURFACE
I STEEL
1 2 3 4 5 6 7
REMARKS:
1 RUN OUT SIZE SAME SIZE AS DIFFUSERNECK SIZE, U.N.O. ON DWGS.
2 ALL DIFFUSERS TO HAVE SIDE INLET SFEET METAL CAN PLENUM IF < 1.5 DIA STRAIGHT FLEX AVAILABLE FOR TOP INLET
3 ECCO MFG DIFFUSER CAN TO HAVE PERFORATED INTERIOR PLATE (AND 1" SOUNDLINING IF SPACE <- NC -30 OR SAT < 55°F)
4 STANDARD WHITE POWDER COAT
5 PROVIDE FRAME 3P, LAY -IN TYPE.
6 PROVIDE SURFACE MOUNTING FRAME MODEL SMF FOR GRILLE REMOVAL & INSTALLATION IN HARD LID CEILING
7 WHERE VOLUME DAMPERS ARE NOT ACCESSIBLE, PROVIDE HAND HOLE ACCESS OR YOUNGS REGULATOR WITH CEILING PLATE
OR DURODYNE CABLE OPERATED DAMPER WITH CABLE ROUTED INSIDE DUCT & ADJUSTMENT THROUGH GRILLE FACE
RECEIVED
CITY OF TUKWILA
MAR 0 8 2016
PERMIT CENTER
Hermanson Company LLP
1221 2nd Avenue North
Kent, Washington 98032
Tel: (206) 575-9700
Fax: (206) 575-9800
www.hermanson.com
Contractor Reg #: HERMACLO05BJ
URGENT CARE
TUKWILA PRECOR
17275 SOUTHCENTER PARKWAY
TUKWILA, WA 98188
Revisions
_
02/26/16 JMH ISSUE FOR PERMIT
No. Date By Description
Design Team
Design JMH
Drawn
FVP
Checked MIG
Scale
AS NOTED
Drawing Number C-0589-08037
Project Number 11-16-08037
Issue Date 02/24/16
SCHEDULE SHEET
Hv s` -REVIEWED OR
CODE COMPLIAW
APPROVED
MAR 2 5 2116
City Of Tukwila
BUILDING DIVISION
1a
ON T
J
SCALE: 4"=1'
1' 3' 5' 10' 15'
YW1V1•1\V 1 V
DEMO EXISTING DUCTWORK AND DIFFUSER BACK TO UNIT.
25'
2' 4'
RECEIVED
CITY OF TUKWILA
MAR 0 8 2016
PERMIT CENTER
ISSUE FOR PERMIT
Hermanson
Hermanson Company LLP
1221 2nd Avenue North
Kent, Washington 98032
Tel: (206) 575-9700
Fax: (206) 575-9800
www.hermanson.com
Contractor Reg #: HERMACLO05BJ
URGENT CARE
TUKWILA PRECOR
17275 SOUTHCENTER PARKWAY
TUKWILA, WA 98188
Revisions
02/26/16 JMH ISSUE FOR PERMIT
No. Date By Description
Design Team
Design JMH
Drawn FVP
Checked MIG
Scale AS NOTED
Drawing Number C-0589-08037
Project Number 11-16-08037
Issue Date 02/24/16
1ST FLOOR PLAN
- HVAC_
REVIEWED FOR
CODE COMPLIANCE
APPROVED
U' u
City of Tukwila
BUILDING DIVISION
SCALE: 4 '=1 '
1 ' 3' 5' 10' 15'
25'
2' 4'
RECEIVED
CITY OF TUKWILA
MAR 0 8 2016
PERMIT CENTER
ISSUE FOR PERMIT
Hermanson Company LLP
1221 2nd Avenue North
Kent, Washington 98032
Tel: (206) 575-9700
Fax: (206) 575-9800
www.hermanson.com
Contractor Reg #: HERMACLO05BJ
URGENT CARE
TUKWILA PRECOR
17275 SOUTHCENTER PARKWAY
TUKWILA, WA 98188
Revisions
02/26/16 JMH ISSUE FOR PERMIT
No. Date By Description
Design Team
Design JMH
Drawn FVP
Checked MIG
Scale AS NOTED
Drawing Number C-0589-08037
Project Number 11-16-08037
Issue Date 02/24/16
M=�E
V &IEvvEO Ft3R
C®DE COMPLIANCE
APPROVED
MAR 2 5 2010
City of Tul(wila
BUILDING DIVISION