Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Permit M16-0042 - WSP SOUTH KING COUNTY - FURNACE REPLACEMENTS, HEAT PUMPS, WATER HEATER
WSP SOiTTH KING COUNTY 15700 PACIFIC EI\VY S M16-0042 City of Tukwila • Department of Community Development • 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-438-9350 Web site: http://www.TukwilaWA.eov MECHANICAL PERMIT Parcel No: 2223049029 Permit Number: M16-0042 Address: 15700 PACIFIC HWY S Issue Date: 4/12/2016 WA Cities Electrical Code: 2014 Permit Expires On: 10/9/2016 Project Name: WSP SOUTH KING COUNTY 2014 Owner: 2012 WA State Energy Code: Name: WA STATE PATROL 2012 Address: PO BOX 42626 8623 ARMSTRONG RD SW, OLYMPIA, WA, 98504 Contact Person: Name: KEN SMITH Phone: (253) 539-0141 Address: PO BOX 1315, SPANAWAY, WA, 98387 Contractor: Name: T R S MECHANICAL INC Phone: (253) 539-0141 Address: PO BOX 1315, SPANAWAY, WA, 98387 License No: TRSMEI*977B7 Expiration Date: 2/9/2017 Lender: Name: Address: DESCRIPTION OF WORK: REPLACE 2 GS FURNACES AND INSTALLING 2 HEAT PUJPS WITH THEM. INSTALL ONE HOT WATER HEATER IN PACE OF ANOTHER. Valuation of Work: $24,500.00 Fees Collected: $520.26 Type of Work: Electrical Service Provided by: SEATTLE CITY LIGHT Fuel type: Water District: 125 Sewer District: VALLEY VIEW SEWER SERVICE Current Codes adopted by the City of Tukwila: International Building Code Edition: 2012 National Electrical Code: 2014 International Residential Code Edition: 2012 WA Cities Electrical Code: 2014 International Mechanical Code Edition: 2012 WAC 296-46B: 2014 Uniform Plumbing Code Edition: 2012 WA State Energy Code: 2012 International Fuel Gas Code: 2012 Permit Center Authorized Signature: Dater I hearby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this development permit and agree to the conditions attached to this permit. / Signature: Date: 4�1' 12— Print 2 6 6 Print Name: This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: Work shall be installed in accordance with the approved construction documents, and any changes made during construction that are not in accordance with the approved construction documents shall be resubmitted for approval. 2: All permits, inspection record card and approved construction documents shall be kept at the site of work and shall be open to inspection by the Building Inspector until final inspection approval is granted. 3: Readily accessible access to roof mounted equipment is required. 4: All construction shall be done in conformance with the Washington State Building Code and the Washington State Energy Code. 5: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of this requirement. 6: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206-431-3670). 7: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center. 8: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 9: `MECHANICAL PERMIT CONDITIONS' 10: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431-3670). 11: Manufacturers installation instructions shall be available on the job site at the time of inspection. PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 0703 MECH EQUIP EFF 1800 MECHANICAL FINAL 0609 PIPE/DUCT INSULATION 0705 REFRIGERATION EQUIP 0701 ROUGH -IN MECHANICAL CITY OF TUKWILA Community Development Department Permit Center • 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 ' http:/hvww.TukwilaWA._oovv SITE LOCATION Mechanical Permit No. IV 1 l w7y' Project No. Date Application Accepted: Date Application Expires:11 r use MECHANICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **please print** Site Address: Tenant Name: �� C �/" c King Co Assessor's Tax No.: lY �� Suite Number: New Tenant: Address: D Floor: El ..... Yes �No City: City: State: Zip: PROPERTY OWNER Name: Name: Address: D Address: City: City: State: Zip: CONTACT PERSON — person receiving all project communication Name: 1 S- Address: D State: (� � City: State: Zip Phone Fax JJ Email: IWA iM n y MECHANICAL CONTRACTOR INFORMATION Company Name:: c f l Address: y� �)N 11 (�1A 1 S- City: o �u)() o �l State: (� � Zip Phone: q— Fax. 5 23 Contr Reg No.: Exp ate: Tukwila Business License No.: M rIt Valuation of project (contractor's bid price): $_� q I , _ Describe the scope of work in detail: �/� /� C f � s �-� , � e— S V 1W_,CM . // -75is m Use: Residential: New .......... ❑ Replacement ........ ❑ Commercial: New .......... Replacement .......Ifi Fuel Type: Electric..... Gas ....... 4� Other: H:\Applications\Forms-Applications On Line\2016 ApplicationsWcchanical Permit Application Revised 1.4-16.docx Revised: January 2016 Page 1 of 2 bh Indicate type of mechanical work being installed and the quantity below: Unit Type Qty Furnace <100k btu Residential, Nighttime Fumace>100k btu Industrial Floor furnace 55 dB(A) Suspended/wall/floor mounted heater 57 dB(A) Appliance vent Commercial Repair or addition to heat/refrig/cooling system 47 dB(A) Air handling unit <10,000 cfm 65 dB(A) Unit Type Qty Air handling unit >10,000 cfm Residential, Nighttime Evaporator cooler Industrial Ventilation fan connected to single duct 55 dB(A) Ventilation system 57 dB(A) Hood and duct Commercial Incinerator — domestic 47 dB(A) Incinerator — comm/industrial 65 dB(A) Unit Type Qty Fire damper Residential, Nighttime Diffuser Industrial Thermostat 55 dB(A) Wood/gas stove 57 dB(A) Emergency enerator Commercial Other mechanical equipment 47 dB(A) 60 dB(A) 65 dB(A) Boiler/Compressor Qty 0-3 hp/100,000 btu Residential, Nighttime 3-15 h /500,000 btu Industrial 15-30 hp/1,000,000 btu 55 dB(A) 30-50 hp/1,750,000 btu 57 dB(A) 50+ h /1,750,000 btu Commercial 57 dB(A) 47 dB(A) 60 dB(A) 65 dB(A) Noise: Mechanical units need to be in compliance with the Tukwila Noise Code. Maximum permissible sound levels are based on from where the sound is created and where the sound is heard. Additionally, if sound can be heard from within a house at night in a residential zone it may not be allowed. For more details, see TMC 8.22 District of Sound Producing Source District of Receiving Property Residential, Daytime* Residential, Nighttime Commercial Industrial Residential 55 dB(A) 45 dB(A) 57 dB(A) 60 dB(A) Commercial 57 dB(A) 47 dB(A) 60 dB(A) 65 dB(A) Industrial 60 dB(A) 50 dB(A) 65 dB(A) 70 dB(A) *Daytime means 7AM-IOPM, Monday through Friday and 8AM-IOPM, Saturday, Sunday and State -recognized holidays. A few sounds are exempt from the noise code, including: Warning devices; Construction and property maintenance during the daytime hours (lam -I Opm); Testing of backup generators during the day. PERMIT APPLICATION NOTES - Value of construction — in all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the permit center to comply with current fee schedules. Expiration of plan review — applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The building official may grant one extension of time for additional periods not to exceed 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. City State zip MApplicationsTo=-Applications On Line\2016 Applications\Mechanical Permit Application Revised 14-16.&" Revised: January 2016 Page 2 of 2 bh DESCRIPTIONS PermitTRAK ACCOUNT QUANTITY $653.21 EL16-0324 Address: 15700 PACIFIC HWY S Apn: 2223049029 $81.80 ELECTRICAL $77.90 PERMIT FEE MULTI-FAM/COMM R000.322.101.00.00 0.00 $77.90 TECHNOLOGY FEE $3.90 TECHNOLOGY FEE R000.322.900.04.00 0.00 $3.90 M16-0042 Address: 15700 PACIFIC HWY S Apn: 2223049029 $420.21 MECHANICAL $400.20 PERMIT ISSUANCE BASE FEE R000.322.100.00.00 0.00 $32.50 PERMIT FEE R000.322.100.00.00 0.00 $367.70 TECHNOLOGY FEE $20.01 TECHNOLOGY FEE R000.322.900.04.00 0.00 $20.01 PG16-0036 Address: 15700 PACIFIC HWY S Apn: 2223049029 $151.20 GAS $32.50 PERMIT ISSUANCE BASE FEE R000.322.100.00.00 0.00 $32.50 PLUMBING $111.50 PERMIT ISSUANCE BASE FEE R000.322.100.00.00 0.00 $32.50 PERMIT FEE R000.322.100.00.00 0.00 $79.00 TECHNOLOGY FEE $7.20 TECHNOLOGY FEE TOTAL R8178 11000.322.900.04.00 0.00 $7.20 $653.21 Date Paid: Tuesday, April 12, 2016 Paid By: KENNETH SMITH Pay Method: CREDIT CARD 06707G Printed: Tuesday, April 12, 2016 1:56 PM 1 of 1 r771' r-VISYsTEMs DESCRIPTIONS ACCOUNT QUANTITY PAID PermitTRAK $136.06 M16-0042 Address: 15700 PACIFIC HWY S Apn: 2223049029 $100.05 MECHANICAL $100.05 PLAN CHECK FEE R000.322.102.00.00 0.00 $100.05 PG16-0036 Address: 15700 PACIFIC HWY S Apn: 2223049029 $36.01 GAS $8.13 PLAN CHECK FEE R000.322.103.00.00 0.00 $8.13 PLUMBING $27.88 PLAN CHECK FEE TOTAL$136.06 13000.322.103.00.00 0.00 $27.88 Date Paid: Tuesday, March 15, 2016 Paid By: KENNETH SMITH Pay Method: CREDIT CARD 05572G Printed: Tuesday, March 15, 2016 11:55 AM 1 of 1 EVET SYSTEMS INSPECTION RECORD `r Retain a copy with permit —00 If Z INSPE ION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Proje.ti.� Type of,lns Ad rs- �� 106 i u c. P 1 Date Called: Special Instructions: Date Wante a.m. p.m. lRequIster: Phone No: nspector: REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. 0 INSPECTION RECORD n--5 Retain a copy with permit A 16 —ov N&KCTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project: kr— Type(Al Inspecti A d e s: �S'7 00 Date Called 0 Special Instructi ns: A Date planted: a.m. p.m. Requester:. Phone No: 0 REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION RECORD 2 Retain a copy with permit " IN ECTI OR NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 mPermit Inspection Request Line (206) 438-9350 Me + P`rojgcctt: Type f I egtion: Adf3ss:/' i t t // 7700 �.i U W �l Dat Called: Special Instructions: Date Wanted- a.m. fyi p.m. Requester; ^, Phlo�n'e�1Vo: q" (Inspector: e6-- IDate: S`rZ ��j REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. SEPARATE PERMIT REQUIRED FOR: 0 Mechanlod 6tlectricei 01 -Plumbing [ Gas PipkV City of Tukwffa DIVISION fi �. - - — - I I' Neuc- uamwa a.w O(dq' M. WA MAIN FLOOA, PLAN bAStffitajR P _ t G4� A ^4M ^^.: ..w•�M. _ -_'cWin,. "'b 61EPNFl•IT IAt1CATING OETAGkOTiQ �A'.l. tJfH K1N0 OxJ AICFUKD °JOUiI.iOf'I A. .ergo WASHN6IDM 5TATE r _ M e PSN ' PILS RNG'SCN MEl6 W -� �a STATE OF WASHINGTON - DEPARTMENT OF GENERAL ADMINISTRATION - DIV. OF ENGINEERING & ARCHITECTURE.. REVISIONS Nochanges shalt be made to the scope of work without prior approval of r uki,vila Building Division. NOTA: Fov;sic Is will require a new plan submittal and may include additional plan review fees. l REAWE-D FOR 'DNCE APR 0 7 2016 A-7 VA of Tukwfla BU(I�OINf3 DIVI310N FILE COPY Permit No.-M.1s2.--00JI Plan review approval is subject to errors and ornissiort- & nmval of construction documents does not authorize the violation of any adopted cod© or ordinance. Recent of approver,; f=ield Copy and con i i . s is acknowledged: By: l Date: z +mow City of TuWla BUILDING DIVISION RECEIVED CITY OF TUKWILA BAR 15 2016 PERMIT CENTER tAJ4. Ooy2 3/15/2016 Google Maps FIL Imagery @2016 Google, Map data @2016 Google 10ftL-- -- I Google Maps REVTIEWED FOR- 00DE"COMPUANCE APPMV60 APR 0 7 2016 City of Tukwila ,SUfLd1f4G olvi-SION hftps:/twww.google.com/maps/@47.4627595,-122.2896325,141a,20y,270[Vdata=!3m 1!le3 RECEIVED CITY OF TUKWILA MAR 15 20 PERMIT CENT'r'_*H- hi OVID M1 4- 4qW-W 1/1 1 1-1/4" bushing 2 1-1/4"xlx3/4" Tee 3 1-1" 90 Ell FILE REVIEWED FOR .ODE COMPLIANCE APPOOVED APR 0 7 2016 City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA MAR 15 2016 PERMIT CENTER EcoSenso° Rheem EcoSense® ultra low NOx, mid -efficiency tankless gas water heaters are designed to provide continuous hot water Efficiency ❑ .82 EF with all copper heat exchanger ❑ Intelligent electronic controls designed to increase energy efficiency and safety ❑ Third party efficiency listed by AHRI Performance ❑ Industry First! 0.26 GPM minimum flow rate, 0.40 GPM minimum activation flow rate ❑ ECO200 for 3 bathroom homes' - 9.5 gal./min. at 35°F rise max., 8.4 gal./min. at 45°F rise ❑ ECO180 for 2-3 bathroom homes' - 8.4 gal./min. at 35°F rise max., 6.6 gal./min. at 45°F rise ❑ ECO150 for 1-2 bathroom homes' - 6.4 gal./min. at 35°F rise max., 5.6 gal./min. at 45°F rise Self -Diagnostic System ❑ Self-diagnostic system for easy installation and service ❑ Digital display shows precise temperature setting and maintenance codes Technology ❑ 3"/5" concentric vent system with Integrated condensate collector ❑ Hot start programming helps minimize fluctuation in water tem- perature, referred to as "cold water sandwich", during periods of frequent on/off operation ❑ Connects to Metal Fab. Inc., 3"/5" concentric venting without an adapter ❑ Built-in electric blower ❑ Exclusive! Overheat film wrap (OFW) to protect the heat exchanger ❑ EZ -Link cable available for higher demand applications to connect two tankless units to operate as one ❑ Manifold up to six units with an optional MIC -6 manifold control board ❑ Manifold up to 20 units with the optional MIC -185 plus the MICS -180 manifold control assembly Low Emissions ❑ Environmentally friendly Ultra Low NOx burner meets SCAQMD rule 1146.2 requirements High Altitude Compliant ❑ High-altitude capability - up to 9,840 ft. elevation above sea level Plus... ❑ Digital remote control and 10 ft. of thermostat wire included ❑ Supplied with a 120 volt power cord (indoor models only) ❑ Freeze protection to -30°F ❑ Required manual gas isolation valve included R,E�EWED FOR )SWE I=PLIANCE APPROVED APR 0 7 WE 0 Cit! of TUWI0 IBUILDING DIVISION Indoor Direct Vent Outdoor Rheem EcoSense® Mid -Efficiency Tankless 11 000-199 900 Bt /h Warranty u ❑ 12 -Year limited warranty on heat exchanger, 5 -year limited warranty on parts and 1 -year limRt EQaU6E D on labor CITY OF TUKWVILA See written warranty for complete details r MAR 15 2diS on simultaneous showers using 2n gallons gallons per minute. cold des tyy �ig�n R, C �. on temperature of cold J a � 1 ' V E F � ' � ' .� LEER Pants = 2 See dimensions chart on back. 09/14 FOAM NO. THD -3196 fcoSen e Rheem EcoSense® Mid -Efficiency Tankless DESCRIPTION FEATURES ROUGHING IN DIMENSIONS (SHOWN IN INCHES) ENERGY INFO. 2 GAS 3 36 ft. (11 m) MIN. FLOW/ GPM ® GPM ® 33.0 ft. (10.0 m) 6 31.5 ft. (9.5 m) SHIP. EST. YEARLY MODEL INPUT TEMP. ACTIVATION 77' RISE 45' RISE MAX. CONNECTION VENT WEIGHT ENERGY RECOVERY ENERGY COST NUMBER ULTRA LOW NOxFOR BTUM TYPE 3 BATHROOMHOMES RANGE GPM MAX MAX GPM HEIGHT WIDTH DEPTH DIAM. (LBS.) FACTOR EFFIGENCY NATM WATER GAS ECO200DVL3 11,000- Indoor a5*° t0 0.26/0.40 4.3 7.4 9.5 3/4 3/4 25-5/8 13-7/8 9-7/8 3 by 5 54 84% $199/482 ECO200DVLP3 199,900 Direct vent 140° F' coNceNrnic .82 ECO200XLN3 11,000- 85* to [9.5 ECO200XLP3 ULTRA LOW NOxFOR 199,900 Outdoor 2-3 140° F' BATHROOM 0.26/0.40 HOMES 4.3 7.4 3/4 3/4 23-5/8 13-7/8 8-7/8 N/A 54 .82 83% $199/482 ECO180DVLN311,000- Indoor 85° to 0.26/0.40 3.9 6.7 8.4 3/4 3/4 25-5/8 13-7/8 9-7/8 3 by 5 54 84% $199/482 EC0180DVLP3 180,000 Grect m 140-F coNCENMIc .82 EC0180XLN3 11,000- Outdoor 85° to 0.26/0.40 3.9 6.7 8.4 3/4 3/4 23-5/8 13-7/8 8-7/8 N/A 54 83% $199/482 EC0180XLP3 ULTRA LOW NOxFOR 180,000 1-2 140° F BATHROOM HOMES .82 EC0150DVLN3 11,000 - Indoor 85° to 0.26/0.40 3.3 5.6 6.4 3/4 3/4 25-5/8 13-7/8 9-7/8 3 by 5 54 84% $199/482 EC0150DVLP3 150,000 Direct vent 140° F corrcE l .82 ECO150XLN3 11,000- 85° to EC0150XLP3 150,000 Outdoor 140-F 0.26/0.40 3.3 5.6 6.4 3/4 3/4 23-5/8 13-7/8 8-7/8 N/A 54 .82 83% $199/482 Energy Factor and Average Annual Operating Costs based on 2013 D.O.E. (Department of Energy) test procedures. O.O.E. national average fuel rate natural gas $1.09Ahenn; LP $2.41 /gallon. All models are available in Natural Gas and Propane (LP). For Propane replace the N with P when ordering. • SCOAMO rule 1146.2 compliant. • Factory set maximum temperature is 120° F. See Use and Care Manual for setting. • Consult factory for information on sizing the application. Vent Termination Kits are required for Direct Vent models. Proper gas pressure must be ensured to supply tankless gas water heaters - up to 199,900 Stu/h for ECO200 models, up to 180,000 Btu/h for ECO180 models and up to 150,000 Stu/h for EC0150 models. (Consult your gas supplier) Temperature Rise (° F) Model Number 35° 45° 50° 60° 70° 77° 80° 90° 100° E00200 Water Flow (GPM) 9.5 7.4 6.6 5.5 4.7 4.3 4.1 3.7 3.3 ECO180 Water Flow (GPt1/1) 8.4 6.7 6.1 5.1 4.3 3.9 3.8 3.4 3.0 ECO150 Water Flow (G" 6.4 5.6 5.1 4.2 3.6 3.3 3.2 2.8 2.5 Above estimates are for sizing purposes only GPM Water Heater Flow Rate Curves 10 ........,._�...___-....__ ._._..�. 8 .___....._........_._.__.._.__. ECO200 Max. Flow 7 •� ECO180 Max. Flow •-' EC0150 Max. Flow 6 s 4 3 2 I 0 10 20 35 45 50 60 70 77 60 90 100 120 140 Alfa -T Parts and Accessories Maximum Vent Length (intake/outlet): Number of 90° Elbows Maximum Length of Straight Pipe 1 39.0 ft. (12.0 m) 2 37.5 ft. (11.5 m) 3 36 ft. (11 m) 4 34.5 ft. (10.5 m) 5 33.0 ft. (10.0 m) 6 31.5 ft. (9.5 m) (Manufacturer approved venting required) Venting & terminations, recess boxes, pipe covers, extra remote controls, EZ -Link, manifolds and cables, service valve kits, service parts, flush kits For more information on Tankless parts and accessories, see the Parts and Accessories catalog or call 866-720-2076. Indoor Direct Vent 5, 1-135"Con-ft 25 Me �- 9,1e -► t-- 13/e' -� T o 4%, ? a• o�sore � I f 5• y cera_ I�r,e Outdoor 23W c oo• o 4t, 24z S2 V. Vr rSVa'->• irle Oi clItxsflan t5 y In keeping with its policy of continuous progress and product improvement, Rheem reserves the right to make changes without notice. Rheem Water Heating • 101 Bell Road Montgomery, Alabama 36117-4305 • www.rheem.com x 09/14 FORM NO. THD -3196 LENNDX Product Submittal • t n rru,juct 1111urrnatiun Project Name: Tukwila Job — Revision #1 Project Number: 3000542234 Project Location: TUKWILA, WA 00000, US Project Altitude: 1000 Customer Information Company Name: Air Commodities Inc Company Address: 6100 6th Ave S Company Location: Seattle, WA 98108-3308 Contact: Phone: 800-875-2473 Engineering Information Company Name: Company Address: Company Location: Contact: Phone We are pleased to provide the attached project submittal, If you have any questions or need additional information, please feel free to call our office. Project: 3000542234 Tukwila Job Last Changed: GIVENS, DAN Quote: 4000641611 Tukwila Job Prepared On: 2015-11.13 Page 1 of 25 Phone: 800-875-2473 Lennox Industries Inc. - Product Submittal Table of Contents System ID Qty Model Description UP -FLOW SPLIT 1 14HPX-060-230 HEAT PUMP/5TON/230-1 LVR SYSTEM 1 CX34-62C-F COIL/5TON/CASED 1 ML180UHIIOXP60C FURNACE/GAS/11013TUH/5TON DOWN -FLOW SPLIT 1 14HPX-060-230 HEAT PUMP/5TON/230-1 LVR SYSTEM 1 CR33-50/60C COIL/4-5TON CASED 1 ML 180DF I I OXP60C FURNACE/GAS/ I I OBTUH/5T UP -FLOW 95% AFUE 1 14HPX-060-230 HEAT PUMP/5TON/230-1 LVR OPTION 1 CX34-62C-F COIL/5TON/CASED 1 ML1.95UHIIOXP60C FURNACE-GAS/110BTUH/5T DOWN -FLOW 95% AFUE 1 14HPX-060-230 HEAT PUMP/5TON/230-1 LVR OPTION 1 CR33-50/60C COIL/4-5TON CASED 1 ML195DF110XP60C FURNACE-GAS/110BTUH/5TON Project: 3000542234 Tukwila Job Last Changed: GIVENS, DAN Quote: 4000641611 Tukwila Job Prepared On: 2015-11-13 Page 2 of 25 Phone: 800-875-2473 Lennox Industries Inc. - Product Submittal System ID: UP -FLOW SPLIT SYSTEM Condenser Model: 14HPX-060-230 Description: HEAT PUMP/5TON/230-1 LVR Evaporator Coil Model: CX34-62C-F Description: COIL/5TON/CASED Furnace Model: MLI80UHI IOXP60C Description: FURNACE/GAS/l IOBTUH/5TON HEATING PERFORMANCE Heat Source Natural Gas HSPF (IV) 8.50 HP Output@Design 36600 (Btuh) HP DesignTemp 17.0 (°F) HP Output@470 55000 (Btuh) HP Output@17° 36600 (Btuh) HP COP@470 3.26 HP COP@17° 2.48 H/E HighInput 110000 (Btuh) Gas Supply Connection 0.50 (in.) H/E HighOutput 89000 (Btuh) HIE DischargeDB 60.8 (°F) Coil GrossSensCool 51683 (Btuh) H/E Heat Rise 43.1 (°F) Unit NetSensCool 48506 (Btuh) AFUE/ ThermalEff 80 COOLING PERFORMANCE Refrigerant R -410A Number Compressors 1 ARI EER 12.2 Number of Cooling Stages 1 ARI SEER 14.7 Cooling OutdoorDB 95.0 (°F) ARI NetTotalCool 61000 (Btuh) Cooling CondenserDB 95.0 (°F) Coil GrossTotalCool 64534 (Btuh) Cooling MixedDB 80.0 (°F) Unit NetTotalCool 61357 (Btuh) Cooling MixedWB 67.0 (°F) Coil GrossSensCool 51683 (Btuh) Coil DischargeDB 54.5 (°F) Unit NetSensCool 48506 (Btuh) Coil DischargeWB 54.5 (°F) Cond Liquid Line 3/8 (in.) Unit DischargeDB 56.1 (°F) Cond Suction Line 1 1/8 (in.) Unit DischargeWB 56.1 (°F) Coil Liquid Line 3/8 (in.) Coil MoistureRemoval 12.1 (lb/hr) Coil Suction Line 7/8 (in.) System MoistRemoval 12.1 (lb/hr SUPPLY FAN PERFORMANCE Supply AirFlow 1913 (cfm) TotalStaticPress 0.64 (in.WC) ExtStaticPress Supply 0.30 (in.WC) Wet Coil Static Press 0.34 (in.WC) SupplyFan Req'dPower 1.00 (hp) SupplyFan NomPower 1.00 (hp) Supply Fan Type CAV Direct Drive SupplyDrive Speed MED -HIGH ELECTRICAL Condenser Voltage 208V 1Ph Furnace Voltage 120V 1Ph Frequency 60 (Hz) Condenser MCA 29.4 (amp) Condenser MOCP 50 (amp) Cond Oper Range -Nom Voltage +/_10% Unit O er Range -Nom Voltage +/_10% DIMENSIONS CondensingUnit Height 43.3 (in.) CondensingUnit Weight 295 (lb) CondensingUnit Width 32.3 (in.) Coil/Coil Fan Weight 77 (lb) CondensingUnit Length 32.3 (in.) Furnace Weight 161 (lb) Coil/Coil Fan Height 31.5 (in.) Furnace Height 33.0 (in.) Coil/Coil Fan Width 21.0 (in.) Furnace Width 21.0 (in.) Coil/Coil Fan Length 22.0 (in.) Furnace Length 28.5 (in.) SOUND Outdoor Sound Rating 80 (db) Project: 3000542234 Tukwila Job Last Changed: GIVENS, DAN Quote: 4000641611 Tukwila Job Prepared On: 2015-11-13 Page 3 of 25 Phone: 800-875-2473 Lennox Industries Inc. - Product Submittal System ID: UP -FLOW SPLIT SYSTEM - Condenser Model: 14HPX-060-230 Description: HEAT PUMP/5TON/230-1 LVR Evaporator Coil Model: CX34-62C-F Description: COIL/5TON/CASED Furnace Model: MLI80UHI IOXP60C Description: FURNACE/GAS/110BTUH/5TON DIMENSIONS - INCHES (MM) INLET AIR INLET S � - INLET AIR t i/ AI'RR ..._.."_SUCTION LINE _ CONNECTION INLT 4 A82 �UOUID LINE CONNECTION TOP VIEW 43'8 4.38 4.3fi) 3 OP'nONAL UNIT w r STAND -OR- KIT (4) l (real In: aW) Ilp c4sanrResspst COIL DRAIN OUTLETS ✓"liu IArand oerr elftf of base) 4.3,18 ELECTRICAL INLETS saae 4ae (sez) (ass) TOP VIEW BASE SECTION A OUTDOOR DISCHARGE AIR 00ILFAN \ COMPRESS SUCTION A LIOUID LI CONNECT) 2-: oPTToNAL uNIt SIDE VIEW STAN DOIT )(IT (4) (FIELD INSTALLED) Modell No. A iTches m B inches mm Cm inches mm 14HPX-018-230 28-1/4 718 25�-114 743 28-112 724 14HPX-024-30 28-114 718 37-1/4 946 36-1/2 927 14HPX-030-230 28-114 718 37-1/4 946 36-1/2 927 14HPX 036-230 28-1/4 718 33-1/4 845 32-112 826 14HPX-042-230 32-114 819 37-1/4 946 36-112 927 14HPX-048-230 32-114 819 37.114 946 .36-1/2 927 14HPX-060-230 32-114 819 43-1/4 1099 42-1/4 1073 Project: 3000542234 Tukwila Job Last Changed: GIVENS, DAN Quote: 4000641611 Tukwila Job Prepared On: 2015-11-13 Page 4 of 25 Phone: 800-875-2473 Lennox Industries Inc. - Product Submittal System ID: UP -FLOW SPLIT SYSTEM Condenser Model: 14HPX-060-230 Description: HEAT PUMP/5TON/230-1 LVR Evaporator Coil Model: CX34-62C-F Description: COIL/5TON/CASED Furnace Model: MLI80UHI IOXP60C Description: FURNACE/GAS/1 I OBTUH/5TON DIMENSIONS - INCHES (MM) CX34-18/24, -30, -36, -38 and -42B Coils 314 (19) CASED COILS 3/4(19) I 19-1/2 No (495) C OUTLET OPENING 3/4 (19) 3/4 (19) TOP VIEW A 21 3/4 {533) (19) H - i SUCTION ` LINE 1 a B LIQUIDf / l G LINE i / 1 E It Cf li �F AIR 1-1/2 1-1/4 FLOW Ji (38) _' 1 (32) INLET 2-518 9116 ( INLET OPENING (67)CONDENSATE 2 519 6 OPENING 9116 D 9116 ( ) jjj��+ (14) FRONT VIEW (14) (14) SIDE VIEW Model A B C D E F G H Number in. mm in. I mm in. mm inmm in. mm in. mm in. mml in. mm CX34A8/24A-6F 14-1/2 368 16-1/21419 13 330 13-3/8 340 11-1/8 283 8-1/8 206 2-3/4 70 1 3-718 98 CX34-181246-6F 17-1/2 445 16-112 419 16 406 16-3/8 416 11-1/4 286 8-1/4 210 3 76 4-118 105 CX34-18/24C-6F 21 533 16-112 419 19-112 495 19-718 505 11-1/4 286 8-1/4 210 3 76 4-118 105 CX34-30A-6F 14-1/2 368 20-1/2 521 13 1330113-3/8 340.15-1/4 387,12-114,311 2-314 70 3-7/8 98 CX34-30B-6F 17-1/2 445 20-1/2 521 16 406 16-3/8 416 15-114 387 12-1/4 311 3 76 4-118 105 CX34-30C-6F 21 533,20-1,2,521 19-1/2 495 19-7/8 505 15-114 387 12-1/4 311 3 76 4-1/8 105 CX34-36A-6F 14-112 368124-1/2 1622 13 330 13-318 340 19-1/4 489 16-318 416 2-3/4 70 3-718 98 CX34-366-6F 17-112 445124-1121622 16 406 16-3/8 416 18-5/8 473 15-518 397 3 76 4-1/8 105 CX34-36C-6F 21 533 24-1/21622.19-1/2 495.19-7/8 505 19-518 498 16518 422 4-3/4 121 3-5/8 92 CX34-38A-6F 14-1/2 368 24-112 1622 13 330 13-3/8 340 18-118 464 15-38 391 2-3/4 70 3-718 98 CX34-38B-6F 17-1/2 445 24-1/2 622 16 14061163/8 416 18-318 467 15-112 394 2-3/4 70 3-7/8 98 CX34-42B-6F 17-1,T 445 24-1/2 1622 16 1406116-3!8 416 18-518 467 15-518 397 3 1 76 1 4-1/8 1105 Project: 3000542234 Tukwila Job Last Changed: GIVENS, DAN Quote: 4000641611 Tukwila Job Prepared On: 2015-11-13 Page 5 of 25 Phone: 800-875-2473 Lennox Industries Inc. - Product Submittal Jystem ID: UP -PLOW SPLIT SYSTEM Condenser Model: 14HPX-060-230 Description: HEAT PUMP/5TON/230-1 LVR Evaporator Coil Model: CX34-62C-F Description: COIL/5TON/CASED Furnace Model: ML180UHI IOXP60C Description: FURNACE/GAS/110BTUH/5TON DIMENSIONS - INCHES (MM) CX34-19A, -25, -31, -43, -44!48, -50/60C, -60D and -62D Coils (NOTE - See next page for CX34-49C-6F and CX34-62C-6F Coils) NOTE- CX34-60D and CX34-62D coils are positioned in cabinet with coil face running left to right, all other coil sizes are positioned like drawing. 314 (19) l !/ 1-112 1-1/4 E F 1 (38) (32f INLET 2 518 OPENING (671 D 9/16 9116 (14) FRONT VIEW (14) 314 (19) 314 (19) 19-112 (495) C OUTLET OPENING 3/4 (19) TOP VIEW CASED COILS 314 (19) INLET CONDENSATE 20-7116 OPENING 9116 DRAINS (519) (14) SIDE VIEW Model A C D I E F G H Number in. 'm m in. mm in. mm in. mm in. mm in. mm in. LIQUID I i CX34-19A-6F 14-1/2 368 16-1/2 419 LINE 330 13-3/8 340 10-7/8 276 13-7/8 353 3 76 3-7/8 98 CX34-25A-6F 14-112, 368 18-112 470 G 330 13-3/8 340 12-7/8 327 15-718 403 SUCTION J j 3-7/8 98 CX34-25B-6F LINE ( / 406 16-318 416 12-718 327 15-7/8 403 b 83 4-1/8 �t CX34-31A-6F H 13 330 13-318 340 12-318 314 15-318 391 1 i 38 2-318 60 314 (19) l !/ 1-112 1-1/4 E F 1 (38) (32f INLET 2 518 OPENING (671 D 9/16 9116 (14) FRONT VIEW (14) 314 (19) 314 (19) 19-112 (495) C OUTLET OPENING 3/4 (19) TOP VIEW CASED COILS 314 (19) INLET CONDENSATE 20-7116 OPENING 9116 DRAINS (519) (14) SIDE VIEW Model A I B C D I E F G H Number in. 'm m in. mm in. mm in. mm in. mm in. mm in. mm in. mm CX34-19A-6F 14-1/2 368 16-1/2 419 13 330 13-3/8 340 10-7/8 276 13-7/8 353 3 76 3-7/8 98 CX34-25A-6F 14-112, 368 18-112 470 13 330 13-3/8 340 12-7/8 327 15-718 403 3 76 3-7/8 98 CX34-25B-6F 17-1/2 445 18-1/2 470 16 406 16-318 416 12-718 327 15-7/8 403 3-114 83 4-1/8 105 CX34-31A-6F 14-1/2 368 22-1/2 572 13 330 13-318 340 12-318 314 15-318 391 1-1/2 38 2-318 60 CX34-31B-6F 17-1/2 445 22-1/2 572 16 406 16-3/8 416 12-3/8 314 15-3/8 391 3-1/4 83 4-1/8 105 CX34-43B-6F 17-112 445 27-112 699 16 406 16-3/8 416 16-314.425 19-3/4 502 3-1/4 83 4-1/8 105 CX34-43C-6F 21 533 27-112 699 19-112 495 19-7/8 505 16-314 425 19-314 502 2-3/4 70 3-5/8 92 CX34-441486-6F 17-112 445 24-112 622 16 406 16-318 416 9-3/4 248 12-3/4 324 3 76 4-118 105 CX34-44/48C-6F 21 533 24-1/2 622 19-1/2 495 19-7/8 505 12-3/4 324 15-3/4 400 4-1/4 108 5-3/8 137 CX34-50160C-6F 21 533 27-1/2 699119-1/2 495119-7/8 505 16-112 419 19-112 495 2-1/2 64 3-5/8 92 CX34-60D-6F 24-1/2 622 25-1�6481 584 23-3/8 594 11-7/8 302 14-718 518 1-5/8 41 2-314 70 CX34-62D-6F 24-1/2 622 29-15B4123-318 1594 18-718 479 21-7/8 556 1-518 41 2-314 70 Project: 3000542234 Tukwila Job Last Changed: GIVENS, DAN Quote: 4000641611 Tukwila Job Prepared On: 2015-11-13 Page 6 of 25 Phone: 800-875-2473 T o.,■,..� T"Alvvo+.-:mac. T.,.. D—, —4. ystem ID: UP -FLOW SPLIT SYSTEM .ondenser Model: 14HPX-060-230 Description: HEAT PUMP/5TON/230-1 LVR ,vaporator Coil Model: CX34-62C-F Description: COIL/5TON/CASED 'urnace Model: ML180UHI IOXP60C Description: FURNACE/GAS/110BTUH/5TON DIMENSIONS - INCHES (MM) CX34-49C-6F and CX34-62C-6F CASED COILS 3/4(119) 1-314 19412 10 3/4 (44) (495) (19) 19-1/2 (495) OUTLET OPENING 314 (19) TOP VIEW 22 �(533)� 3/4 _ (559) (1�1 LIQUID LINE ( / ` 2-112 SUCTION ! 1 (64) C LINE I / 1 � 1 3-518 1 1 (92) j / BAIR 1 i-112. �Z 1-114 A FLOW f jl (38) (32) L- ___ I: INLET 2-5/8 ice- INLET o OPENING (67) � CONDENSATE OPENING -i►{ 19-7/8-- - IN DRAINS 21-7/16 9116 9116 (505) 9f16 (545) (14) (14) FRONT VIEW (14) SIDE VIEW Model A B C Number in. mm in. I mm I in. Tmm CX34-49C-2F 15-7/8 403 1873/4 476 129-1/2 749 CX34-62C-2F 18-7/8 479 21-7/8 556 31-1/2 800 Project: 3000542234 Tukwila Job Quote: 4000641611 Tukwila Job Page 7 of 25 Last Changed: GIVENS, DAN Prepared On: 2015-11-13 Phone: 800-875-2473 Lennox Industries Inc. - Product Submittal System ID: UP -FLOW SPLIT SYSTEM Condenser Model: 14HPX-060-230 Description: HEAT PUMP/5TON/230-1 LVR Evaporator Coil Model: CX34-62C-F Description: COIL/5TON/CASED Furnace Model: MLI80UHI IOXP60C Description: FURNACE/GAS/I IOBTUH/5TON 'NOTE - 60C and 60D size units that require second stage air volumes over 1830 cfm must have one of the fallowing: 1. Single side return air with transition, to accommodato 20 x 25 x 1 to. (508 x 635 x 25 mm) cleanable air fitter. Required to mairlt n. proper air vela;ity. 2. Single site return air with optional Return Air Base 3. Bottom return air. 4. Return sit from both sides. 5. Bottom aad one side return air. See B'kn+ar Perbrmance Tables fol additional inbrnlation. t Flue outlet may be horizontal but fumaioe must be vented verticaly 3 Optional External Side Return Ab Fiter Kit is not for use with the optional Return Air Base. am (19) A A }�--- B 9J16(14) I- (594) j i 3OPTIONAL in. o oa ooaanaaeao ononaananaaan EXTERNAL a no 000naanao 11111199/1/1119 aaa SIDE RETURN mm AIR FILTER KIT a oa 9119911999911 (Either Side) 9aaaaaaaaa9a9 33 119999 .999991111 0 119 1111 911119 9 9 0 9 (83f / I� I 1-15116 (49) Q7li I 14- I (37s)5) I16 j (406) I I XIL180UH0451*38A sr8 1 C�113 (16) ' Sonom Return Air Openirg FRONT VIEW 3.118(79) D FLUEOUTLET 00000 (Top) 00000 00000 00000 11111190 U00000 SUPPLY AIR OPENING 'OPTIONAL I (6 3 AL EXTERNj+ (6p3)) SIDE RETURN 25 AIR FILTER KIT (635) (Either Side) TOP VIEW 314(19} 2705) Front Panel (I 5) 3-114 (83) 3 (76) Right 19-7116 9116 6314 (171) Left (494) (14) 1 2FLUEOUTLET 9-1/8(232)Right ! + (Ether Side) 8-'q8 (219) Leo ___ELECTRICAL INLET I (Either Sde) 5-3)8 (137) Right I ( J 'GAS PIPING INLET 1A116(4dj Leo (51he' Si(Je) 3-116 23-112 (83) (597) — ' Bosom Return Air Opening SIDE VIEW Model No. A B ELECTRICAL INLET(Eilrle(Side) I- (594) j i 1-112 (38) in. Side Return 114 I in. (EitterSide) I AirOlBring (356) mm in. (Either Side) 1 1.10 60UH045P24A JI ----------- 1-15116 (49) 3-116 23-112 (83) (597) — ' Bosom Return Air Opening SIDE VIEW Model No. A B C D in. mm in. mm in. mm in. mm 1.10 60UH045P24A XIL180UH0451*38A MLiSOUH07OP24A 14112 388 13-3.18 340 13 330 4-314 121 h1L180UH070P38A KILISOUH-09OP358 ML1SOUHG90P485 17-112 446 16.318 416 16 408 8-114 159 A4L180UH110P48C �t 533 1P-7/8 594 19.112 495 8 203 MLI SOUH 1 IOP80C %41-180UH135P600 24-112 622 23.318 1 546 23 J 584 9-314 248 Project: 3000542234 Tukwila Job Quote: 4000641611 Tukwila Job Page 8 of 25 Last Changed: GIVENS, DAN Prepared On: 2015-11-13 Phone: 800-875-2473 Lennox Industries Inc. - Product Submittal System ID: UP -FLOW SPLIT SYSTEM -ondenser Model: 14HPX-060-230 Description: HEAT PUMP/5TON/230-1 LVR evaporator Coil Model: CX34-62C-F Description: COIL/5TON/CASED Furnace Model: MLI80UHI IOXP60C Description: FURNACE/GAS/110BTUH/5TON 'NOTE -60C and 60D size units that require second stage air volumes over 1830 cfm must have one of the fo0owirg: 1. Single side return air with transition, to accommodate 20 x 25 x 1 in. (508 x 635 x 25 mm) cleanable ab fitter. Required to maintain proper air veb:;ity. 2. Sing1a site return air with optional Return Air Base 3. Botbm retum air. 4. Return sit from both sides. 5. Bottom 3rLdone side return air. See B(vner Porbmtance Totes for additional information. 2 Flue outlet may be horizontal but furnace must be ve rued vertically 3 Optional External Side Return Air Filter Kit is not for use with the optional Return Air Base. a�a y {19} A A B 9116(td) D 3OPTIONAL q aq eq ngngaeaq gins nn nnagaaaq nnagnnnae�naa aagnaaana can EXTERNAL SIDE RETURN mm AIR FILTER KIT e as �a�eaa n eaq (Esher Side) eeaaaaeneanae 33 qae as nnaaa eaa ggqnqaqnqqqnn (838 / I1�II 14-3v (1 -FDI (375) �I 16 M06) II �I3,14 f,4L180U11.045P38A tl C `�1`r 1 {f6} Project: 3000542234 Tukwila Job Quote: 4000641611 Tukwila Job Page 9 of 25 ' Bottom Retum Air Opening FRONT VIEW 3-118(79) T as 40 I 00 eo D Ij �J / . SUPPLY AIR OPENING FLUE OUTLET cocoa (TCP) a11BUD cocoa cacao cacao cocoa OPTIOEXTERNAL ` (6 3) _I EXTERNAL jam-- {603j SIDE RETURN 25 AIR FILTER KIT (635) (Either Side) TOP VIEW 3.a{f9} I 27.914 Front, (705) 3-114(83) 3 (76) f39h1 79.7176 63i4 (171) Left (494) 19"6 (14) 4-118 (234 Rig 8{/8 (219) Le I 5318(,37) Right _._�_f_I 'GAS PIPING INLET I 1-4/16(40)Let ���I (Either Side) I— --------- ELECTRICAL /�I INLET (Either Side) Ir -- ( ) X311 I 'Side Return 14 I (Either Side) I Air Opening (i) (Either Side) ----------1—J 3 1 4 ( 23-112 i83y `I � X97} — 'BOIIem Return Air Opening SIDE VIEW Last Changed: GIVENS, DAN Prepared On: 2015-11-13 Phone: 800-875-2473 A B C D Model No. in. mm in. mm in. mm in. mm 1,4L180UH045P24A f,4L180U11.045P38A hIL160UH070P24A 14-112 368 13-318 340 13 330 4-314 121 i4080UH070P35A ML180UH090P388 hIL160UH090P488 17-1/2 448 16-3.18 416 16 408 a-114 159 f,4L180UH110P48C ML780UHI10P80C '11 533 19-7/8 5D4 19-112 495 8 203 i,4L180UH135P80D 24-112 1 822 1 23.318 548 '3 584 9-314 248 Last Changed: GIVENS, DAN Prepared On: 2015-11-13 Phone: 800-875-2473 Lennox Industries Inc. - Product Submittal System ID: L)UWN-rLUW SPLIT SYSTEM Condenser Model: 14HPX-060-230 Description: HEAT PUMP/5TON/230-1 LVR Evaporator Coil Model: CR33-50/60C Description: COIL/4-5TON CASED Furnace Model: MLI8ODFI IOXP60C Description: FURNACE/GAS/l IOBTUH/5T HEATING PERFORMANCE Heat Source Natural Gas HSPF (IV) 8.20 HP Output@Design 38000 (Btuh) HP DesignTemp 17.0 (°F) HP Output@47° 58500 (Btuh) HP Output@17° 38000 (Btuh) HP COP@47° 3.08 HP COP@17° 2.38 H/E Highlnput 110000 (Btuh) Gas Supply Connection 0.50 (in.) H/E HighOutput 89000 (Btuh) H/E DischargeDB 57.7 (°F) Coil GrossSensCool 49308 (Btuh) H/E Heat Rise 40.4 (°F) Unit NetSensCool 46131 (Btuh) AFUE/ ThermalEff 80 COOLING PERFORMANCE Refrigerant R -410A Number Compressors 1 ARI EER 11.7 Number of Cooling Stages 1 ARI SEER 14.2 Cooling OutdoorDB 95.0 (°F) ARI NetTotalCool 58500 (Btuh) Cooling CondenserDB 95.0 (°F) Coil GrossTotalCool 62467 (Btuh) Cooling MixedDB 80.0 (°F) Unit NetTotalCool 59290 (Btuh) Cooling Mixed" 67.0 (°F) Coil GrossSensCool 49308 (Btuh) Coil DischargeDB 55.7 (°F) Unit NetSensCool 46131 (Btuh) Coil DischargeWB 55.7 (°F) Cond Liquid Line 3/8 (in.) Unit DischargeDB 57.3 (°F) Cond Suction Line 1 1/8 (in.) Unit DischargeWB 57.1 (°F) Coil Liquid Line 3/8 (in.) Coil MoistureRemoval 12.4 (lb/hr) Coil Suction Line 7/8 (in.) System MoistRemoval 12.4 (lb/hr SUPPLY FAN PERFORMANCE Supply AirFlow 2038 (cfm) Total StaticPress 0.66 (in.WC) ExtStaticPress Supply 0.30 (in.WC) Wet Coil Static Press 0.36 (in.WC) SupplyFan Req'dPower 1.00 (hp) SupplyFan NomPower 1.00 (hp) Supply Fan Type CAV Direct Drive SupplyDrive Speed MED -HIGH ELECTRICAL Condenser Voltage 208V 1Ph Furnace Voltage 120V 1Ph Frequency 60 (Hz) Condenser MCA 29.4 (amp) Condenser MOCP 50 (amp) Cond Oper Range -Nom Voltage +/-10% Unit O er Range -Nom Voltage +/-10% DIMENSIONS CondensingUnit Height 43.3 (in.) CondensingUnit Weight 295 (lb) CondensingUnit Width 32.3 (in.) Coil/Coil Fan Weight 85 (lb) CondensingUnit Length 32.3 (in.) Furnace Weight 160 (lb) Coil/Coil Fan Height 23.6 (in.) Furnace Height 33.0 (in.) Coil/Coil Fan Width 24.5 (in.) Furnace Width 21.0 (in.) Coil/Coil Fan Length 26.1 (in.) Furnace Length 28.5 (in.) SOUND Outdoor Sound Rating 80 (db) Project: 3000542234 Tukwila Job Last Changed: GIVENS, DAN Quote: 4000641611 Tukwila Job Prepared On: 2015-11-13 Page 10 of 25 Phone: 800-875-2473 Lennox Industries Inc. - Product Submittal system 11): UUWN-PLUW SYLH SYSTEM Condenser Model: 14HPX-060-230 Description: HEAT PUMP/5TON/230-1 LVR Evaporator Coil Model: CR33-50/60C Description: COIL/4-5TON CASED Furnace Model: ML18ODFI IOXP60C Description: FURNACE/GAS/1 IOBTUH/5T INCLUDED SYSTEM OPTIONS - FIELD INSTALLED 91M02 1 100188-02 VALVE -EXP 3.5-6 TON (R4IOA) Project: 3000542234 Tukwila Job Last Changed: GIVENS, DAN Quote: 4000641611 Tukwila Job Prepared On: 2015-11-13 Page 11 of 25 Phone: 800-875-2473 Lennox Industries Inc. - Product Submittal System 11): DUWN-FLOW SPLI"1' SYSTEM Condenser Model: 14HPX-060-230 Description: HEAT PUMP/5TON/230-1 LVR Evaporator Coil Model: CR33-50/60C Description: COIL/4-5TON CASED Furnace Model: ML180DFI IOXP60C Description: FURNACE/GAS/11013TUH/5T DIMENSIONS - INCHES (MM) INLET L AIR {1St} (litg 4>341 43,6 OPTLONAL UNI! INLET STAND -Off #CIS' (4) wc4d Insuud) III C'f!IlJB'RESS IR 4 \ ! ) l AIR --_' ;QR COIL "RAN OUTLIETS (Anand pehlwkrof Lase) t, SUCTION LIrJE�� IS52j '� 43,19 CONNECTION c_...- _ (tM INLET 4 AIR UOUID LINE CONNECTION 43,6 (t E2) {itti) TOP VIEW TOP VIEW BASES ECTION SIDE VIEW ELECTRICAL INL INLETS Ir 2 1St ) aro (ts) A OL11DOOR r DISGHARGE AIR COMPRESSOR SUCTION AND L IOUID L I E COrJNECTTOra 2-3x4170) ----� �j OPTIONAI UNIT SIDE VIEW STAN DOST KIT (4 ) (L•IL3O INSTALLED) Model No. A inches mm B inches mm C inches mm 14HPX-018-230 28-1/4 718 29-114 1 743 28-1/2 724 14HPX-024-230 28-1/4 718 37-114 946 36-112 927 14HPX-030-230 28-1/4 718 37=114 946 36-1/2 927 14HPX-036-230 28-1/4 718 33-1/4 845 32-1/2 826 14HPX-042-230 32-1/4 819 37-114 946 36-112 927 14HPX-048-230 .32-1/4 819 37.1/4 946 36-1/2 927 14HPX-060-230 32-1/4 819 1 43-1/4 1099 42-114 1073 Project: 3000542234 Tukwila Job Last Changed: GIVENS, DAN Quote: 4000641611 Tukwila Job Prepared On: 2015-11-13 Page 12 of 25 Phone: 800-875-2473 Lennox Industries Inc. - Product Submittal System ID: DOWN -FLOW SPLIT SYSTEM Condenser Model: 14HPX-060-230 Description: HEAT PUMP/5TON/230-1 LVR Evaporator Coil Model: CR33-50/60C Description: COIL/4-5TON CASED Furnace Model: ML180DFI IOXP60C Description: FURNACE/GAS/I IOBTUH/5T DIMENSIONS - INCHES (MM) `rt B inlet N C Opening H (1GTiON E 4�7! A I -3J32 LIQUID - �Gj % (28) LINE r T � F 2 571 �(25)1 Outlet 1 (25) Opening FRONT VIEW 26-118 (664) 22.518 Inlet 1 (25) (575) Opening AIR FLOW Z CONDENSATE DRAIN 5116 S( t=1 23-3/16 Outlet (251) (589) Opening f� SIDE VIEW Model Number A in. mm B in, mm O in. mm D in. mm E in. mm F in, mm G in. mm H' in. rnm CR33-18A-F 14-118 359 1.7-112 445 131/2 343 15.1/2 394 8.314 222 6-114 159 3 76 2 51 CR33-24A-F 13-114 337 17-1/2 445 13112 343 15-112 394 8.314 222 6.1/4 159 3 76 2 51 CR33-24B-F 13-114 337 17-12 445 1.61/2 419 15-112 394 63/4 222 6.1/4 159 3 76 1t2 13 CR33-30/36A-F 16-118 410 1'•7-12 445 13.1/2 343 15-112 394 83,'4 222 6-1/8 156 3 76 2 51 CR33.30/36B-F 16-1/8 410 17-12 445 16.112 419 151,12 394 8314 222 6-1/8 155 3 76 12 13 CR33-30/360-F 16-1/8 410 21 533 20 508 19 483 10-1/2 267 6-118 156 3 76 12 13 CR33-48B-F 20 508 21 533 16.1/2 419 19 483 10-1/2 267 8-1/8 206 4 102 -114 57 CR33-48G,.F 20 508 21 533 20 508 19 483 10-1/2 267 8-118 206 4 102 12 13 CR33-501600-F 23-x/8 600 2412 622 20 508 22-112 572 12-1/4 311 12-518 321 4 102 -1/4 57 CR33-60D-F 23.5/8 600 24-12 622 23.1/2 597 22-112 572 12-1/4 311' 125.18 321 4 102 1Q 13 Project: 3000542234 Tukwila Job Quote: 4000641611 Tukwila Job Page 13 of 25 Last Changed: GIVENS, DAN Prepared On: 2015-11-13 Phone: 800-875-2473 Lennox Industries Inc. - Product Submittal system n): UP-PLUW 95%AFUE OPTION Condenser Model: 14HPX-060-230 Description: HEAT PUMP/5TON/230-1 LVR Evaporator Coil Model: CX34-62C-F Description: COIL/5TON/CASED Furnace Model: MLI95UHI IOXP60C Description: FURNACE-GAS/110BTUH/5T HEATING PERFORMANCE Heat Source Natural Gas HSPF (IV) 8.50 HP Output@Design 36600 (Btuh) HP DesignTemp 17.0 (°F) HP Output@47° 55000 (Btuh) HP Output@170 36600 (Btuh) HP COP@47° 3.26 HP COP@17° 2.48 H/E Highlnput 110000 (Btuh) Gas Supply Connection 0.50 (in.) H/E HighOutput 105000 (Btuh) H/E DischargeDB 65.1 (°F) Coil GrossSensCool 51683 (Btuh) H/E Heat Rise 48.3 (°F) Unit NetSensCool 48506 (Btuh) AFUE/ ThermalEff 95 COOLING PERFORMANCE Refrigerant R -410A Number Compressors 1 ARI EER 12.2 Number of Cooling Stages 1 ARI SEER 14.7 Cooling OutdoorDB 95.0 (°F) ARI NetTotalCool 61000 (Btuh) Cooling CondenserDB 95.0 (°F) Coil GrossTotalCool 64534 (Btuh) Cooling MixedDB 80.0 (°F) Unit NetTotalCool 61357 (Btuh) Cooling MixedWB 67.0 (°F) Coil GrossSensCool 51683 (Btuh) Coil DischargeDB 54.5 (°F) Unit NetSensCool 48506 (Btuh) Coil DischargeWB 54.5 (°F) Cond Liquid Line 3/8 (in.) Unit DischargeDB 56.1 (°F) Cond Suction Line 1 1/8 (in.) Unit DischargeWB 56.1 (°F) Coil Liquid Line 3/8 (in.) Coil MoistureRemoval 12.1 (lb/hr) Coil Suction Line 7/8 (in.) System MoistRemoval 12.1 (lb/hr SUPPLY FAN PERFORMANCE Supply AirFlow 2014 (cfm) Total StaticPres s 0.64 (in.WC) ExtStaticPress Supply 0.30 (in.WC) Wet Coil Static Press 0.34 (in.WC) SupplyFan Req'dPower 1.00 (hp) SupplyFan NomPower 1.00 (hp) Supply Fan Type CAV Direct Drive SupplyDrive Speed HIGH ELECTRICAL Condenser Voltage 208V 1Ph Furnace Voltage 120V 1Ph Frequency 60 (Hz) Condenser MCA 29.4 (amp) Condenser MOCP 50 (amp) Cond Oper Range -Nom Voltage +/-10% Unit Oper Range -Nom Voltage +/-10% DIMENSIONS CondensingUnit Height 43.3 (in.) CondensingUnit Weight 295 (lb) CondensingUnit Width 32.3 (in.) Coil/Coil Fan Weight 77 (lb) CondensingUnit Length 32.3 (in.) Furnace Weight 164 (lb) Coil/Coil Fan Height 31.5 (in.) Furnace Height 3 3. 0 (in.) Coil/Coil Fan Width 21.0 (in.) Furnace Width 21.0 (in.) Coil/Coil Fan Length 22.0 (in.) Furnace Length 28.8 (in.) SOUND Outdoor Sound Rating 80 (db) Project: 3000542234 Tukwila Job Last Changed: GIVENS, DAN Quote: 4000641611 Tukwila Job Prepared On: 2015-11-13 Page 14 of 25 Phone: 800-875-2473 Lennox Industries Inc. - Product Submittal Nystem 10: UP-rLU W 95% Al, UE UY110N Condenser Model: 14HPX-060-230 Description: HEAT PUMP/5TON/230-1 LVR Evaporator Coil Model: CX34-62C-F Description: COIL/5TON/CASED Furnace Model: ML195UHI IOXP60C Description: FURNACE-GAS/110BTUH/ST INCLUDED SYSTEM OPTIONS - FIELD INSTALLED 69M29 1 VENT KIT - 2" CONCENTRIC Project: 3000542234 Tukwila Job Quote: 4000641611 Tukwila Job Page 15 of 25 Last Changed: GIVENS, DAN Prepared On: 2015-11-13 Phone: 800-875-2473 Lennox Industries Inc. - Product Submittal Jystem 10: UP-PLU W 95% AFUE OPTION Condenser Model: 14HPX-060-230 Description: HEAT PUMP/5TON/230-1 LVR Evaporator Coil Model: CX34-62C-F Description: COIL/5TON/CASED Furnace Model: ML195UHI IOXP60C Description: FURNACE-GAS/11013TUH/5T DIMENSIONS - INCHES (MM) INLET -& Alit INLET- 1 �^ INLET Alit AIR i SUMICN LINE ~ti _ 00NNECT7GN 0111-0,4 AIR LIQUID LINE CONNECTION TOP VIEW s �w..riew SIDE VIEW \ ELECTRICAL INLET'S 2(57) 3,w /taf A €MDOOR i)ISCHARGEAIR COIL FAN \ COMPRESSOR SUCTION AND (. LIOUD LINE CONNL'C110N EEiiFER 2-39(70) ---- -F— X OP1106VfZ uNit SIDE VIEW STANDOM KIT44) (FlaD INSTALLED) Model Ido. 4.3'8 (itt} a3�8. (1171 B inches 434} C inches mm 43,E {4711 STAND OPrK)NI'T KIT' (4) ... f /� (it.t) (Few Iflem kd) E7�fhPRT=55SJR 724 ODIC DRAIN OU'itEr5 \ti�JI 718 (Around peM -W 01 baSe)f 946 36-1/2 927 14HPY.-030-230 28-1/4 o-3'$ (t52) 37-1/4 t a 3,4 927 14HPX-036-230 28-114 718 1 33-1/4 845 32-1/2 826 6J1H 4a,Ql 819 37-114 4162) (ti111 927 TOP VIEW BASESECT10N \ ELECTRICAL INLET'S 2(57) 3,w /taf A €MDOOR i)ISCHARGEAIR COIL FAN \ COMPRESSOR SUCTION AND (. LIOUD LINE CONNL'C110N EEiiFER 2-39(70) ---- -F— X OP1106VfZ uNit SIDE VIEW STANDOM KIT44) (FlaD INSTALLED) Model Ido. A inches mm B inches mm C inches mm 14HPX-018-230 28-1/4 718 29-1/4 743 28-112 724 14HPX-024-230 28-1/4 718 37-114 946 36-1/2 927 14HPY.-030-230 28-1/4 718 37-1/4 946 36-112 927 14HPX-036-230 28-114 718 1 33-1/4 845 32-1/2 826 14HPX-042-230 32-114 819 37-114 946 36-112 927 14HPX-048-230 32-114 819 37-1/4 946 36-112 927 14HPX-060-230 32-1/4 819 43-1/4 1099 42-114 1073 Project: 3000542234 Tukwila Job Last Changed: GIVENS, DAN Quote: 4000641611 Tukwila Job Prepared On: 2015-11-13 Page 16 of 25 Phone: 800-875-2473 Lennox Industries Inc. - Product Submittal System Ill: UP -FLOW 95%AFUE OPTION Condenser Model: 14HPX-060-230 Description: HEAT PUMP/5TON/230-1 LVR Evaporator Coil Model: CX34-62C-F Description: COIL/5TON/CASED Furnace Model: MLI95UHI IOXP60C Description: FURNACE-GAS/110BTUH/5T DIMENSIONS - INCHES (MM) CX34-18!24, -30, -36, -38 and -42B Coils 3/4 (1g) CASED COILS 3/4(19) 19-112 (495) C 0 LET OPENING 3/4 (19) 314 (19) TOP VIEW A 21 314 (533) (19) i H - f SUCTION l ` LINE f / LIQUID f lrG B LINE / f 4 1 E f AIR ( r 1-1/2 1-114 FLOW (38) wa (32) INLEt 2-518 OPENING (671 I INLET 9116 D CONDENSATE I 20-7116 dPENING 9116 DRAINS (519) 9116 (14) FRONT VIEW (14) (14) SIDE VIEW Model A B C D E F I G H Number in. mml in. Imm in. Imml in. Imml in. Imm in. imml in. Imml in. Imm CX34-18/24A-6F 14-1/2 368 16-1/2 419 13 1330113-3/8 340111-1/8 283 8-1/81206 2-3/4 17013-718 98 CX34-18/248-6F 17-1/2 445 16-1/2 419 16 1406116-3/8 416111-1/4 286 8-1/4 1210 3 7614-118 105 CX34-18/24C-6F 21 533 16-112 419 19-1t21495119-7/8 505111-1/4 286 8-1/4 210 3 7614-1/8 105 CX34-30A-6F 14-1/2 368 20-1/2 521 13 1330113-318 340115-1/4 387 12-1/4 311 2-314 70 1 3-7/8 98 CX34-30B-6F 17-112 445 20-1/2,521 16 406 16-3/8 416 15-114,387. 12-1/4 311 3 76 4-1/8 105 CX34-30C-6F 21 533 20-1/2 521 19-112 495 19-7/8 505 15-1141387 12-1/4 311 3 76 4-118 105 CX34-36A-6F 14-1/2 368 24-112 622 13 330 13-3/8 340 19-1/4 489 16-318 416 2=314 70 3-7/8 98 CX34-36B-6F 17-1/2 445 24-1/2 622 16 406 16-3/8 416 18-518 473 15-5/8 397 3 76 4-1/8 105 CX34-36C-6F 21 533 24-1/2 622 19-1/2,495,19-718 505,19-5/8 498 16-518 422 4-3/4 121 3-5/8 92 CX34-38A-6F 14-1/2 368 24-1/2 622 13 330 13-3/8 340 18-118 464 15-3/8 391 2-3/4 70 3-718 98 CX34-38B-6F 17-1/2 445124-112 1622 16 406116-3/8 416 18-3/8 467 15-1/2 394 2-3/4 70 3-7/8 98 CX34-428-6F 17-112 445 24-1/2 622 16 406 16-318 416 18-5i8 467 15-5/8 397 3 76 4-118 105 Project: 3000542234 Tukwila Job Last Changed: GIVENS, DAN Quote: 4000641611 Tukwila Job Prepared On: 2015-11-13 Page 17 of 25 Phone: 800-875-2473 Lennox Industries Inc. - Product Submittal ystem ID: UP -FLOW 95% AFUE OPTION .ondenser Model: 14HPX-060-230 Description: HEAT PUMP/5TON/230-1 LVR ;vaporator Coil Model: CX34-62C-F Description: COIL/5TON/CASED 'urnace Model: MLI95UHI IOXP60C Description: FURNACE-GAS/1IOBTUH/5T DIMENSIONS - INCHES (MM) CX34-19A, -25, -31, -43, -44148, -50/60C. -60D and -62D Coils (NOTE -See next page for CX34-49C-6F and CX34-62C-6F Coils) NOTE- CX34-60D and CX34-62D coils are positioned in cabinet with coil face running left to right, all other coil sizes are positioned like drawing. LIQUID / LINE SUCTION f 1 LINE ( J Ir f/ 1-1/2 44tf / (38) LL — — LET 2-5/8_ �IN PENING (67) —D G 314 (19) CASED COILS 3/4 (19) 19-112 314 (495) (19) C OUTLET OPENING 314 (19) TOP VIEW 21 (533) (1919 ) B t F AIR 1-114 FLOW (3?) E INLET 9/16 9116 (14) FRONT VIEW (14) CONDENSATE 20-7116 OPENING 9/16 DRAINS (5 19) (14) SIDE VIEW Model A I B C I D I E F G I H Number in. mm in. mm in. mm in. mm in. mm in. mm in. mm in. mm CX34-19A-6F 14-1/2 368 16-1/2 419 13 330 13-3/8 340 10-7/8 276 13-7/8 353 3 76 3-7/8 98 CX34-25A-6F 14-1/2 368 18-1/2 470 13 330 13-3/8 340 12-7/8 327 15-7/8 403 3 76 3-718 98 CX34-25B-6F 17-1/2 445 18-1/2 470 16 406 16-3/8 416 12-7/8 327 15-718 403 3-114 83 4-1/8 105 CX34-31A-6F 14-1/2 368 22-1/2 572 13 330 13-318 340 12-3/8 314 15-3/8 391 1-112 38 2-18 60 CX34-31B-6F 17-1/2 445 22-112 572 16 406 16-3/8 416 12-3/8 314 15-318 391 3-1/4 83 4-1/8 105 CX34-43B-6F 17-1/2 445 27-1/2 699 16 406 16-318 416 16-3/4 425 19-314 502 3-1/4 83 4-118 105 CX34-43C-6F 21 533 27-1/2 699 19-1/2 495 19-7/8 505 16-314 425 19-3/4 502 2-314 70 3-5/8 92 CX34-44/488-6F 17-1/2 445 24-1/2 622 16 406 16-318 416 9-3/4 248 12-3?4 324 3 76 4-1/8 105 CX34-44148C-6F 21 533 24-1/2 622 19-1/2 495 19-7/8 505 12-3/4 324 15-3/4 400 4-1/4 108 5-3/8 137 CX34-50/640-6F 21 533127-1/2 699 19-1/2 495119-7/8 505 16-112 419 19-1/2 495 2-1/2 64 3-5/8 92 CX34-60D-6F 24-1/2 622125-1/2 648 23 584F223-3/8 594 11-7/81302 14-7/8 518 1-5/8 41 2-314 70 CX34-62D-6F 24-1/2 622129-1/2 749 23 584123-3/8 594 18-7f8 479 21-7/8 556 1-518 41 2-314 70 Project: 3000542234 Tukwila Job Last Changed: GIVENS, DAN Quote: 4000641611 Tukwila Job Prepared On: 2015-11-13 Page 18 of 25 Phone: 800-875-2473 Lennox Industries Inc. - Product Submittal system to: UF—r LU W `JJ% AN UE UY 11UN Condenser Model: 14HPX-060-230 Description: HEAT PUMP/5TON/230-1 LVR Evaporator Coil Model: CX34-62C-F Description: COIL/5TON/CASED Furnace Model: ML195UHI IOXP60C Description: FURNACE-GAS/110BTUH/5T DIMENSIONS - INCHES (MM) CASED COILS CX34-49C-6F and CX34-62C-6F 314 (19) 1-3/4 19-1/2 3/4 (44) (495) (19) 19-1/2 (495) OUTLET OPENING I IF 43/4(19) TOP VIEW 21 22 (533) 3/4 (559) (19) LIQUID LINE! I rl / 1 1 2-1/2 1, C SUCTION (64) LINE 3-518 1 (92) ! ! / AIR 1-1/2 1-1/4 A t3 FLOW Irl / (38) t '� (32) INLET 2-5/8—.JINLET I OPENING(67) —11 CONDENSATE OPENING ' �►�j 19-7/8 21— 9116 9/16 (505) 9116 DRAINS s (5445)5) (14) (14) FRONT VIEW (14) SIDE VIEW Model A B C Number in. mm in. mm in. mm CX34-49C-2F 15 7/8 403 18-3/4 476 29-1/2 749 CX34-62C-2F 18-7/8 479 21-718 556 31-1 /2 800 Project: 3000542234 Tukwila Job Last Changed: GIVENS, DAN Quote: 4000641611 Tukwila Job Prepared On: 2015-11-13 Page 19 of 25 Phone: 800-875-2473 Lennox Industries Inc. - Product Submittal System ID: UP -FLOW 95% AFUE OPTION Zondenser Model: 14HPX-060-230 Description: HEAT PUMP/5TON/230-1 LVR Evaporator Coil Model: CX34-62C-F Description: COIL/5TON/CASED Furnace Model: ML195UHI IOXP60C Description: FURNACE-GAS/110BTUH/5T DIMENSIONS - INCHES (MM) - UPFLOW POSITION c NOTE -60C size units that require air volunt°s aver 1800 drrt muni have one of the following: I. Single side* return air wilt trans'7ion, to acoontmodate 20 x 25 x I In. deanable at ther- Required to malnlain proper air velocity. 2. Singe We return ai► Aith Opla d Rf*.0 n Air Base 3. Bottom re im air. 4. Return air from bodn: sides. 5.8otlorn =done side res im air,. See @aw Pertotttanoe Tades for a tdlotal Infomtalion- 7 Optional Side Retum Air Alier Kh Is not be use wit the O¢lonal Rexim Air Base. 1 (2S 27su FraM Rsn es.. — (705) 8 ^-NO 118 14)1 37118 9116 + 89116P,1873 -2(511 L'2 e t, {Etter xdel 9(2291 1CP OO 4 R'ob GASP)MGNLET SDERiErURIA 12.5'11{321)+„ - (EuttierSide), AlRFLTERKFT {&4" rid )' ! GCNOENSATE (at erSide) 3' --"'TRAPC�OME-CTION ILECTR1GAL, 6�1�1(IB51 NUT (r^er Side) lEfe_rSide) I-----------23 --I 1.4 — {841 (318) t3 7511 I (3 �I 16 1 Side FL -,um 14 Opening I {4031 i (Ehler Side) I AR FLOW JU I1• '16 e491 *' 5 a 314 G "(39I 1 tI' f 191 (63)` 097) Boom Rcum ' Bo'km Reurry Airopeting Air pptnIry FRONTVIEW SIDE VIEW 343x8 EKHAUSTAIR c OUTLET 2(51) Flue CondensateTr'ap ---- mm + Assembly D mm in. Fumished for external -. ML1v95UH045XP24B SUPPLY AIR on eer aide of unit.(See field InstallalonntL4," - OPENING hstallallon Insructions 3or 2-718 -(73) AtR NTAKE addif)malInkxntafon.) 1 (2S 27su FraM Rsn es.. — (705) 8 ^-NO 118 14)1 37118 9116 + 89116P,1873 -2(511 L'2 e t, {Etter xdel 9(2291 1CP OO 4 R'ob GASP)MGNLET SDERiErURIA 12.5'11{321)+„ - (EuttierSide), AlRFLTERKFT {&4" rid )' ! GCNOENSATE (at erSide) 3' --"'TRAPC�OME-CTION ILECTR1GAL, 6�1�1(IB51 NUT (r^er Side) lEfe_rSide) I-----------23 --I 1.4 — {841 (318) t3 7511 I (3 �I 16 1 Side FL -,um 14 Opening I {4031 i (Ehler Side) I AR FLOW JU I1• '16 e491 *' 5 a 314 G "(39I 1 tI' f 191 (63)` 097) Boom Rcum ' Bo'km Reurry Airopeting Air pptnIry FRONTVIEW SIDE VIEW 343x8 EKHAUSTAIR c OUTLET 2(51) I X17 ---- mm + mm D mm in. I J— -. ML1v95UH045XP24B SUPPLY AIR - OPENING / coA1t3t13TiON 2-718 -(73) AtR NTAKE 17-112 446 -----------� OPTONAL SDE RETURN 23314 _ AIR FILTER KIT {603)' (EP.her SFda) 25 40`., #3351 194 TOP VIEW 1 (2S 27su FraM Rsn es.. — (705) 8 ^-NO 118 14)1 37118 9116 + 89116P,1873 -2(511 L'2 e t, {Etter xdel 9(2291 1CP OO 4 R'ob GASP)MGNLET SDERiErURIA 12.5'11{321)+„ - (EuttierSide), AlRFLTERKFT {&4" rid )' ! GCNOENSATE (at erSide) 3' --"'TRAPC�OME-CTION ILECTR1GAL, 6�1�1(IB51 NUT (r^er Side) lEfe_rSide) I-----------23 --I 1.4 — {841 (318) t3 7511 I (3 �I 16 1 Side FL -,um 14 Opening I {4031 i (Ehler Side) I AR FLOW JU I1• '16 e491 *' 5 a 314 G "(39I 1 tI' f 191 (63)` 097) Boom Rcum ' Bo'km Reurry Airopeting Air pptnIry FRONTVIEW SIDE VIEW KL195UH 1 Page 10 Project: 3000542234 Tukwila Job Last Changed: GIVENS, DAN Quote: 4000641611 Tukwila Job Prepared On: 2015-11-13 Page 20 of 25 Phone: 800-875-2473 C D Model; No. in. mm in. mm in- mm in. mm: ML1v95UH045XP24B ML195UH045XP366 17-112 446 16-318 416 16 40`., 7-&8 194 ML1951.11-1070XP36B &1L1'5UHD90XP36G ML195UH090XP48C ML195UH'1I0XP48u 21 533 19-7v'B 505 19 V2495 s 2n'8 238 MI-195U.H1i0Y.P80 ML1961.1H135XP600 24-112 E22 23-318 1 594 23 1 5Z4 9-114 248 KL195UH 1 Page 10 Project: 3000542234 Tukwila Job Last Changed: GIVENS, DAN Quote: 4000641611 Tukwila Job Prepared On: 2015-11-13 Page 20 of 25 Phone: 800-875-2473 Lennox Industries Inc. - Product Submittal System ID: llUWN-FLUW 95%AFUE OPTION Condenser Model: 14HPX-060-230 Description: HEAT PUMP/5TON/230-1 LVR Evaporator Coil Model: CR33-50/60C Description: COIL/4-5TON CASED Furnace Model: ML195DFI IOXP60C Description: FURNACE-GAS/110BTUH/5TON HEATING PERFORMANCE Heat Source Natural Gas HSPF (IV) 8.20 HP Output@Design 38000 (Btuh) HP DesignTemp 17.0 (°F) HP Output@47° 58500 (Btuh) HP Output@17° 38000 (Btuh) HP COP@47° 3.08 HP COP@17° 2.38 H/E HighInput 110000 (Btuh) Gas Supply Connection 0.50 (in.) H/E HighOutput 106000 (Btuh) H/E DischargeDB 66.8 (°F) Coil GrossSensCool 49308 (Btuh) H/E Heat Rise 49.2 (°F) Unit NetSensCool 46131 (Btuh) AFUE/ ThermalEff 95 UOULING PERFORMANCE Refrigerant R -410A Number Compressors 1 ARI EER 11.7 Number of Cooling Stages 1 ARI SEER 14.2 Cooling OutdoorDB 95.0 (°F) ARI NetTotalCool 58500 (Btuh) Cooling CondenserDB 95.0 (°F) Coil GrossTotalCool 62467 (Btuh) Cooling MixedDB 80.0 (°F) Unit NetTotalCool 59290 (Btuh) Cooling MixedWB 67.0 (°F) Coil GrossSensCool 49308 (Btuh) Coil DischargeDB 55.7 (°F) Unit NetSensCool 46131 (Btuh) Coil DischargeWB 55.7 (°F) Cond Liquid Line 3/8 (in.) Unit DischargeDB 57.3 (°F) Cond Suction Line 1 1/8 (in.) Unit DischargeWB 57.1 (°F) Coil Liquid Line 3/8 (in.) Coil MoistureRemoval 12.4 (lb/hr) Coil Suction Line 7/8 (in.) System MoistRemoval 12.4 (lb/hr) SUPPLY FAN PERFORMANCE Supply AirFlow 1997 (cfm) Total StaticPress 0.56 (in. WC) ExtStaticPress Supply 0.20 (in.WC) Wet Coil Static Press 0.36 (in.WC) SupplyFan Req'dPower 1.00 (hp) SupplyFan NomPower 1.00 (hp) Supply Fan Type CAV Direct Drive SupplyDrive Speed HIGH ELECTRICAL Condenser Voltage 208V !Ph Furnace Voltage 120V 1Ph Frequency 60 (Hz) Condenser MCA 29.4 (amp) Condenser MOCP 50 (amp) Cond Oper Range -Nom Voltage +/-10% Unit O er Range -Nom Voltage +/-10% DIMENSIONS CondensingUnit Height 43.3 (in.) CondensingUnit Weight 295 (lb) CondensingUnit Width 32.3 (in.) Coil/Coil Fan Weight 85 (lb) CondensingUnit Length 32.3 (in.) Furnace Weight 164 (lb) Coil/Coil Fan Height 23.6 (in.) Furnace Height 33.0 (in.) Coil/Coil Fan Width 24.5 (in.) Furnace Width 2 1. 0 (in.) Coil/Coil Fan Length 26.1 (in.) Furnace Length 28.8 (in.) NUUND Outdoor Sound Rating 80 (db) Project: 3000542234 Tukwila Job Last Changed: GIVENS, DAN Quote: 4000641611 Tukwila Job Prepared On: 2015-11-13 Page 21 of 25 Phone: 800-875-2473 Lennox Industries Inc. - Product Submittal aystetn 11): UUWN-PLUW 95%AFUE OFFION Condenser Model: 14HPX-060-230 Description: HEAT PUMP/5TON/230-1 LVR Evaporator Coil Model: CR33-50/60C Description: COIL/4-5TON CASED Furnace Model: MLI95DFI IOXP60C Description: FURNACE-GAS/110BTUH/5TON INCLUDED SYSTEM OPTIONS - FIELD INSTALLED 91M02 1 100188-02 VALVE -EXP 3.5-6 TON (R41OA) 69M29 1 VENT KIT - 2" CONCENTRIC Project: 3000542234 Tukwila Job Last Changed: GIVENS, DAN Quote: 4000641611 Tukwila Job Prepared On: 2015-11-13 Page 22 of 25 Phone: 800-875-2473 LtmnnX Indnctriec Inv _ Prnrinvt Cnhmit*-aI Nystem 11): llUWN-PLOW 95%AFUE OPTION Condenser Model: 14HPX-060-230 Description: HEAT PUMP15TON/230-1 LVR Evaporator Coil Model: CR33-50/60C Description: COIL/4-5TON CASED Furnace Model: MLI95DFI IOXP60C Description: FURNACE-GAS/110BTUH/5TON DIMENSIONS - INCHES (MM) A OUTDOOR t DISCHARGE AIR COMPRESSOR SUCTIONAND I. LIQUID LINE WNNC-01`ION ElEC1'RICAL 1M.E15 2-39(70) —� OEYTIONAL UNIT STANODf1=KIT(4) SIDE VIEW (FIELD INSTALLED) Model No. INLET AIR , 4-Y8 {411) B inches f inches INLET 4.i$ 114LET / {ttt) 013110WIL UNIT STAND -017 KIT (4) AIR 4� AR {FWa Insa(ed r11 - - SuCn0N LIME 946 COIL DRAINOLInEI`s 'L CONNECTION 14HPX-034230 Wl.iET ant .UOUIDLINE fONMEC1ION 37-114 TOP VIEW 36-1/2 A OUTDOOR t DISCHARGE AIR COMPRESSOR SUCTIONAND I. LIQUID LINE WNNC-01`ION ElEC1'RICAL 1M.E15 2-39(70) —� OEYTIONAL UNIT STANODf1=KIT(4) SIDE VIEW (FIELD INSTALLED) Model No. 4.3'8 _ (411) , 4-Y8 {411) B inches 43M (111) inches mm. 4.i$ 28-1/4 / {ttt) 013110WIL UNIT STAND -017 KIT (4) 28-112 -.- 14HPX-024-230 {FWa Insa(ed 718 CmNd'RESS 946 COIL DRAINOLInEI`s 'L } 14HPX-034230 {Arowtd MIM*r of tnse) 718 37-114 946 36-1/2 927 ;1 22) 28-1/4 T 4-1,d 845 32-112 826 (n1) 32-1/4 819 as 946 36-112 j162) (4 $2) 14HPX-048-230 32-1/4 TOP VIEW BASE SECTION A OUTDOOR t DISCHARGE AIR COMPRESSOR SUCTIONAND I. LIQUID LINE WNNC-01`ION ElEC1'RICAL 1M.E15 2-39(70) —� OEYTIONAL UNIT STANODf1=KIT(4) SIDE VIEW (FIELD INSTALLED) Model No. A inches mm B inches mm inches mm. 14HPX-018-230 28-1/4 718 29-114 743 28-112 724 14HPX-024-230 28-1/4 718 37-1/4 946 36-112 927 14HPX-034230 28-1/4 718 37-114 946 36-1/2 927 14HPX-036-230 28-1/4 718 33-114 845 32-112 826 14HPX-042-230 32-1/4 819 37-1/4 946 36-112 927 14HPX-048-230 32-1/4 819 37-1/4 946 36-112 927 14HPX-060-230 32-1/4 819 43-114 1099 42-114 1073 Project: 3000542234 Tukwila Job Last Changed: GIVENS, DAN Quote: 4000641611 Tukwila Job Prepared On: 2015-11-13 Page 23 of 25 Phone: 800-875-2473 Lennox Industries Inc. - Product Submittal system 10: 1JU W N -FLU W 9J -/o Al- Uh UPI ION Condenser Model: 14HPX-060-230 Description: HEAT PUMP/5TON/230-1 LVR Evaporator Coil Model: CR33-50/60C Description: COIL/4-5TON CASED Furnace Model: MLI95DFI IOXP60C Description: FURNACE-GAS/1 I OBTUH/5TON DIMENSIONS- INCHES (MM) _IE Inlet FI I � C Opening N CONDENSATE DRAIN 26-1/8 {664) 1(25) 22." Inlet (575) Opening 1.1511+ (49) --- ? opening SIDE VIEW 1 (25) Mode) Number A in. mm B in. mm C in. mm D in. mm S GTi )NE mm F in., mm aPo�l\Tjf1r1 Eti�, G mm A 3132 28) LIQUID LINE �r ; 1" G f 359 17-1f1 \ F 343 15-1/2 394 2 q50 1) Outlet (25) Opening (25) FRONT VIEW CONDENSATE DRAIN 26-1/8 {664) 1(25) 22." Inlet (575) Opening 1.1511+ (49) --- ? opening SIDE VIEW 1 (25) Mode) Number A in. mm B in. mm C in. mm D in. mm E in. mm F in., mm in. G mm in. H mm CR33-18A-F 14-1/8 359 17-1f1 445 13.1/2 343 15-1/2 394 8-W4 222 6-1/4 159 3 16 2 51 CR33-24A-F 13-114 337 17-12 445 131/2 343 15.1/2 394 8.3/4 222 6-1/4 159 3 76 2 51 CR33-24B-F 13.1/4 337 17-12 445 16.1/2 419 15-112 394 8-3+4 222 &1/4 159 3 76 112 13 CR33-30/36A•F 16-1/8 410 17-12 445 1131/2 343 15-1/2 394 8314 222 6.118 156 3 76 2 51 CR33-30/36B-F 16-1/8 410 17-12 445 16.1/2 419 15-1/2 394 8.3/4 222 6-1/8 156 3 76 12 13 CR33-30/36C-F 16-118 410 21 533 20 509 19 483 10-112 267 6-1/8 156 3 76 12 13 CR33-48B-F 20 508 21 533 16-1/2 419 19 463 10-112 267 8-118 206 4 102 -1/4 57 CR33-48C.F 20 506 21 533 20 508 19 483 10-112 267 8-118 206 4 102 12 13 CR33-50/60C-F 23.518 600 24-12 622 20 508 22-1/2 572 12-1/4 311 12-5?8 321' 4 102 -1/4 57 CR33.60D-F 23518 600 24-12 622 23.1/2 597 22-112 572 12-1/4 311 12.518 321 1 4 102 12 13 Project: 3000542234 Tukwila Job Quote: 4000641611 Tukwila Job Page 24 of 25 Last Changed: GIVENS, DAN Prepared On: 2015-11-13 Phone: 800-875-2473 Lennox Industries Inc. - Product Submittal system IV: llU W N -r LU W YJ% Ar U L OF I ION Condenser Model: 14HPX-060-230 Description: HEAT PUMP/5TON/230-1 LVR Evaporator Coil Model: CR33-50/60C Description: COIL/4-5TON CASED Furnace Model: ML195DFI IOXP60C Description: FURNACE-GAS/1 IOBTUH/5TON DIMENSIONS - INCHES (MM) Flue Condensate Trap Assembly Furnished for external field installation on eitherside of unit (See installation instructions for additional information.) A �FLOW AIR 33 (838) 314 C SupplY [_ 314 (19} Air (19} FRONT VIEW (14) COMBUSTION AIR INTAKE J B RETURN AIR EXHAUSTAIRIf I OPENING � OUTLET I J 16 (52) T- 2-1/4 9;16 5 (57) (14) (127) TOP VIEW 1 (25) .0- 27-3/4 _ Front Panel (705) 19-7116_ -u,--9116 (494) (14) i' �- 894 Supply �(i 3/4 9( ) Air9) SIDE VIEW Model No. ELECTRICAL INLET g 0 -- (Either Side) 2A51), Either ide i GAS PIPING INLET ? CONDENSATE (Either Side) QTR 4P CONNECTION (EftherSide) ML195DF045XP36B ML195DF070XP36B + + 446 16-3/8 9-1/8 (232yy Right 69116 ( )Left g (22fl) 6-7/16 (163) Either Side 406 Either Side �- 894 Supply �(i 3/4 9( ) Air9) SIDE VIEW Model No. A g C in. mm in. mm in. mm ML195DF045XP36B ML195DF070XP36B 17-112 446 16-3/8 416 16 406 ML195DF090XP60C ML195DF110XP60C 21 533 19-7/8 505 19-1/2 495 Project: 3000542234 Tukwila Job Quote: 4000641611 Tukwila Job Page 25 of 25 Last Changed: GIVENS, DAN Prepared On: 2015-11-13 Phone: 800-875-2473 4, z MI=Y,-- DIZICIC WAI- 7 'AY' , C 4': c,. c. 52le --T ^A C -z -,&T LLuT!30T Z9?,GaANT k)00 OMKMNO timqcWc C T.0 Y�A+L 7 6NO 4 4-CrO 1 - MAIN F L 0 0 fk pk-Aklq eoe A-3 Ip.5.r,#I-N,F ICING COUNTY STATE OF M E ;11 SOUTm oo cougry )N STATE PATV,,,)L RIVEXTON HEGHT5 INTM"<24 WA5HiKGT0N HINGTON - DEPART NT N fAl�- lr-S,71 WAL_ !o%2T WALL SCLITH Y,&:. W" -:'T NA -L CEILJWV FmWMAV6 ',IQ NAME W- -;,, MAT';, FIN MAT- FIN WTL -IN MA71 lmTL Firi ljo--C; /o y N'. W, ". 1s -' G '�Y- _ I$' ?yl 'p -Ir, TB 4Y. - I :'A CF YWYr HvNT -E A-�, T.Ih- k: ll ' A " -ft -NA- ZC,. ba v3l; r --- T 7 -) :�:T-0 :)T�-) r, --r0C.TrO !�TTO 0,r2' 110 I 0:7 7 DITTO LIWTENAqT ✓,TrO D7- - i X OI -'f0 ;:,Tm07-- ,(veArxc5KAcr, -4- 4 ,70 LATT. CT?I, 7-1 -2- Z,,-= 0-1 o'Trr TIC -ITT' E-�.�-ANT DITTO :i7U 77n r, 5 7��l 0 T.Ar-,O j Oi!7.-) I vi-r-oA r -p Oro ?TTO e :JrtTJ 4 -r-9 P! TTO Lo 7 5Fl-,z4,r ry - ro O OTT-') 7'1' j DITTO O7b 0-M0 71 T-.7 rA-r' L '7' ar 7Vi t;. -r -V 01770a 27F CA rrO t17-0 -0.'V '0i &15r4E aFRJCA rK.— 0 -To c"'q acro7ro OT1=1 '-f'AQZ- I)= Z, T--) = 7V CIT, v6 -y- I fk, �r D.TrV n7"n L/ 77,-� C? 7C :�,T-o p rr��. I, tol- t-;, P 'A- L;!rrc) n - Tc -Arr,: -0 T -.c) �:70 7ZI a -,,g ru rArTo 7, am !Aj-rt-'rj,70P'r0 O:T7ct 9T`j PT -v Ci7--:' ft -A= �- WA"5307 e 15 ..-.N o< v TTV P; C"T-;:, 0-.0 IaT-� CM70 DITTO a Tra 0/4" ON& llp"IT & MUD T T 511c.t L, PPI 07.0 Z: Kj� - I rl T41A 1 1,-,;O tae El+aeeuER>'e644 `T IAK YA.-: EKP,�w I CM_pT ' UNPIN I 'b H 6 1pI, j 14 p I nI e F 0 elf 43, vim'- -VE& 9IJ14T /Z' -"I fttNT pvao .l0Hc WNC FAINT C4214C W." b-4 50jA0 U 'PIN 1 15 H a 0 wewe Li F- 5 H rz V PANT CZ74a F:Ki,4 -r :R^, PAINT AU- I W&YIP OALL WII" PANT --�;Iw-wr FIq, J,.,:�T - , , I 14'LLE50 Co NALL BD 901 U.L.,M, L.-YlEft S Li 14 F 1 N 1 5 rl e Q ovi., Cyf, U N I N 1-5 IYA- W.1 ,bAWACF- 0-Tr7 7 LOOK 00K N, -Y`5Ila'EtAWS .-I A 5`697-0' 11/4 i fz 50'Xa-8? I W V -10,q j _ j'AJNT O C Mr, f -W 6;-8" llB OL�CN Oe""' -IIs147 4. =/6' 50NAT U, f%NT a . r IXHKI ICTAL FtbMIS c 3'-O' X(,.O 1 '/4 '0 FAINT J!Y&l J-....._ �rZ. 'A'8AT, MAT m,5wN Rr.,, awemEAD VAZO ftywmll PAPINL--- awe ty, NICHAKC) BOUILLON Al.A. A & C h I T 6 C , m LIZ00 RAINIERRAINIER5. SEATTLE, Wt'DIV. E*AL ADMINISTRATION - A,bb!&EVJATi'-'N5 C,04c%'llt oil - OUNIM CONT • OZNT, INUOU5 FOL. R-- FOL."50 PLATE QST - DeTAIL, e4miL.Alt, D.S.- COWN SMUT 5HT - 6"67 a1r. - OfWN TILS 6T.- 1-111.11. E.JT- W^N5ICN JOINT Tyr -,rymcAIL- 19N - FINISH TK - TINCK C>/P. WU- 5D- CW?'MM WNI- WARD VW - YMTICAL GA- GAUGE VAT- VINYL A5WST05 TILZ HONZ - 140,JZOSTAL wo - Y40100 M.5 - N",4CMINE _-In_r WOW- WINCOW RECE-1= ZAJN . LSa,$ SIP& PAIN MINIMUM amift) vs .,ivr To �cX ITY 0 Ft 0 K WIC - NOT IN CONTKAC7, WILA O.C.- ON C15NTER 15 2016 CGS kNTlONj RMIT CENTER (D wom r4s eAco- wc-�:,:; WA— LOD#We OETAJ- Ne 51eal H4 [Sheet Contents: MAIN FLOOK PLAN 6, 52tOULF-e Twoed: 3 a (D C-4 v .0 suras. i 4d put"Ic RE,--9T;0H(5T 5UP )F NOTE: wxvoW cw � >UIiT7 as v T V./ iIlA c) (D timqcWc C T.0 Y�A+L 7 6NO 4 4-CrO 1 - MAIN F L 0 0 fk pk-Aklq eoe A-3 Ip.5.r,#I-N,F ICING COUNTY STATE OF M E ;11 SOUTm oo cougry )N STATE PATV,,,)L RIVEXTON HEGHT5 INTM"<24 WA5HiKGT0N HINGTON - DEPART NT N fAl�- lr-S,71 WAL_ !o%2T WALL SCLITH Y,&:. W" -:'T NA -L CEILJWV FmWMAV6 ',IQ NAME W- -;,, MAT';, FIN MAT- FIN WTL -IN MA71 lmTL Firi ljo--C; /o y N'. W, ". 1s -' G '�Y- _ I$' ?yl 'p -Ir, TB 4Y. - I :'A CF YWYr HvNT -E A-�, T.Ih- k: ll ' A " -ft -NA- ZC,. ba v3l; r --- T 7 -) :�:T-0 :)T�-) r, --r0C.TrO !�TTO 0,r2' 110 I 0:7 7 DITTO LIWTENAqT ✓,TrO D7- - i X OI -'f0 ;:,Tm07-- ,(veArxc5KAcr, -4- 4 ,70 LATT. CT?I, 7-1 -2- Z,,-= 0-1 o'Trr TIC -ITT' E-�.�-ANT DITTO :i7U 77n r, 5 7��l 0 T.Ar-,O j Oi!7.-) I vi-r-oA r -p Oro ?TTO e :JrtTJ 4 -r-9 P! TTO Lo 7 5Fl-,z4,r ry - ro O OTT-') 7'1' j DITTO O7b 0-M0 71 T-.7 rA-r' L '7' ar 7Vi t;. -r -V 01770a 27F CA rrO t17-0 -0.'V '0i &15r4E aFRJCA rK.— 0 -To c"'q acro7ro OT1=1 '-f'AQZ- I)= Z, T--) = 7V CIT, v6 -y- I fk, �r D.TrV n7"n L/ 77,-� C? 7C :�,T-o p rr��. I, tol- t-;, P 'A- L;!rrc) n - Tc -Arr,: -0 T -.c) �:70 7ZI a -,,g ru rArTo 7, am !Aj-rt-'rj,70P'r0 O:T7ct 9T`j PT -v Ci7--:' ft -A= �- WA"5307 e 15 ..-.N o< v TTV P; C"T-;:, 0-.0 IaT-� CM70 DITTO a Tra 0/4" ON& llp"IT & MUD T T 511c.t L, PPI 07.0 Z: Kj� - I rl T41A 1 1,-,;O tae El+aeeuER>'e644 `T IAK YA.-: EKP,�w I CM_pT ' UNPIN I 'b H 6 1pI, j 14 p I nI e F 0 elf 43, vim'- -VE& 9IJ14T /Z' -"I fttNT pvao .l0Hc WNC FAINT C4214C W." b-4 50jA0 U 'PIN 1 15 H a 0 wewe Li F- 5 H rz V PANT CZ74a F:Ki,4 -r :R^, PAINT AU- I W&YIP OALL WII" PANT --�;Iw-wr FIq, J,.,:�T - , , I 14'LLE50 Co NALL BD 901 U.L.,M, L.-YlEft S Li 14 F 1 N 1 5 rl e Q ovi., Cyf, U N I N 1-5 IYA- W.1 ,bAWACF- 0-Tr7 7 LOOK 00K N, -Y`5Ila'EtAWS .-I A 5`697-0' 11/4 i fz 50'Xa-8? I W V -10,q j _ j'AJNT O C Mr, f -W 6;-8" llB OL�CN Oe""' -IIs147 4. =/6' 50NAT U, f%NT a . r IXHKI ICTAL FtbMIS c 3'-O' X(,.O 1 '/4 '0 FAINT J!Y&l J-....._ �rZ. 'A'8AT, MAT m,5wN Rr.,, awemEAD VAZO ftywmll PAPINL--- awe ty, NICHAKC) BOUILLON Al.A. A & C h I T 6 C , m LIZ00 RAINIERRAINIER5. SEATTLE, Wt'DIV. E*AL ADMINISTRATION - A,bb!&EVJATi'-'N5 C,04c%'llt oil - OUNIM CONT • OZNT, INUOU5 FOL. R-- FOL."50 PLATE QST - DeTAIL, e4miL.Alt, D.S.- COWN SMUT 5HT - 6"67 a1r. - OfWN TILS 6T.- 1-111.11. E.JT- W^N5ICN JOINT Tyr -,rymcAIL- 19N - FINISH TK - TINCK C>/P. WU- 5D- CW?'MM WNI- WARD VW - YMTICAL GA- GAUGE VAT- VINYL A5WST05 TILZ HONZ - 140,JZOSTAL wo - Y40100 M.5 - N",4CMINE _-In_r WOW- WINCOW RECE-1= ZAJN . LSa,$ SIP& PAIN MINIMUM amift) vs .,ivr To �cX ITY 0 Ft 0 K WIC - NOT IN CONTKAC7, WILA O.C.- ON C15NTER 15 2016 CGS kNTlONj RMIT CENTER (D wom r4s eAco- wc-�:,:; WA— LOD#We OETAJ- Ne 51eal H4 [Sheet Contents: MAIN FLOOK PLAN 6, 52tOULF-e Twoed: 3 a C-4 v suras. i 4d )F NOTE: wxvoW cw � >UIiT7 as v T SAME A� WT, Q�I,'T iIlA timqcWc C T.0 Y�A+L 7 6NO 4 4-CrO 1 - MAIN F L 0 0 fk pk-Aklq eoe A-3 Ip.5.r,#I-N,F ICING COUNTY STATE OF M E ;11 SOUTm oo cougry )N STATE PATV,,,)L RIVEXTON HEGHT5 INTM"<24 WA5HiKGT0N HINGTON - DEPART NT N fAl�- lr-S,71 WAL_ !o%2T WALL SCLITH Y,&:. W" -:'T NA -L CEILJWV FmWMAV6 ',IQ NAME W- -;,, MAT';, FIN MAT- FIN WTL -IN MA71 lmTL Firi ljo--C; /o y N'. W, ". 1s -' G '�Y- _ I$' ?yl 'p -Ir, TB 4Y. - I :'A CF YWYr HvNT -E A-�, T.Ih- k: ll ' A " -ft -NA- ZC,. ba v3l; r --- T 7 -) :�:T-0 :)T�-) r, --r0C.TrO !�TTO 0,r2' 110 I 0:7 7 DITTO LIWTENAqT ✓,TrO D7- - i X OI -'f0 ;:,Tm07-- ,(veArxc5KAcr, -4- 4 ,70 LATT. CT?I, 7-1 -2- Z,,-= 0-1 o'Trr TIC -ITT' E-�.�-ANT DITTO :i7U 77n r, 5 7��l 0 T.Ar-,O j Oi!7.-) I vi-r-oA r -p Oro ?TTO e :JrtTJ 4 -r-9 P! TTO Lo 7 5Fl-,z4,r ry - ro O OTT-') 7'1' j DITTO O7b 0-M0 71 T-.7 rA-r' L '7' ar 7Vi t;. -r -V 01770a 27F CA rrO t17-0 -0.'V '0i &15r4E aFRJCA rK.— 0 -To c"'q acro7ro OT1=1 '-f'AQZ- I)= Z, T--) = 7V CIT, v6 -y- I fk, �r D.TrV n7"n L/ 77,-� C? 7C :�,T-o p rr��. I, tol- t-;, P 'A- L;!rrc) n - Tc -Arr,: -0 T -.c) �:70 7ZI a -,,g ru rArTo 7, am !Aj-rt-'rj,70P'r0 O:T7ct 9T`j PT -v Ci7--:' ft -A= �- WA"5307 e 15 ..-.N o< v TTV P; C"T-;:, 0-.0 IaT-� CM70 DITTO a Tra 0/4" ON& llp"IT & MUD T T 511c.t L, PPI 07.0 Z: Kj� - I rl T41A 1 1,-,;O tae El+aeeuER>'e644 `T IAK YA.-: EKP,�w I CM_pT ' UNPIN I 'b H 6 1pI, j 14 p I nI e F 0 elf 43, vim'- -VE& 9IJ14T /Z' -"I fttNT pvao .l0Hc WNC FAINT C4214C W." b-4 50jA0 U 'PIN 1 15 H a 0 wewe Li F- 5 H rz V PANT CZ74a F:Ki,4 -r :R^, PAINT AU- I W&YIP OALL WII" PANT --�;Iw-wr FIq, J,.,:�T - , , I 14'LLE50 Co NALL BD 901 U.L.,M, L.-YlEft S Li 14 F 1 N 1 5 rl e Q ovi., Cyf, U N I N 1-5 IYA- W.1 ,bAWACF- 0-Tr7 7 LOOK 00K N, -Y`5Ila'EtAWS .-I A 5`697-0' 11/4 i fz 50'Xa-8? I W V -10,q j _ j'AJNT O C Mr, f -W 6;-8" llB OL�CN Oe""' -IIs147 4. =/6' 50NAT U, f%NT a . r IXHKI ICTAL FtbMIS c 3'-O' X(,.O 1 '/4 '0 FAINT J!Y&l J-....._ �rZ. 'A'8AT, MAT m,5wN Rr.,, awemEAD VAZO ftywmll PAPINL--- awe ty, NICHAKC) BOUILLON Al.A. A & C h I T 6 C , m LIZ00 RAINIERRAINIER5. SEATTLE, Wt'DIV. E*AL ADMINISTRATION - A,bb!&EVJATi'-'N5 C,04c%'llt oil - OUNIM CONT • OZNT, INUOU5 FOL. R-- FOL."50 PLATE QST - DeTAIL, e4miL.Alt, D.S.- COWN SMUT 5HT - 6"67 a1r. - OfWN TILS 6T.- 1-111.11. E.JT- W^N5ICN JOINT Tyr -,rymcAIL- 19N - FINISH TK - TINCK C>/P. WU- 5D- CW?'MM WNI- WARD VW - YMTICAL GA- GAUGE VAT- VINYL A5WST05 TILZ HONZ - 140,JZOSTAL wo - Y40100 M.5 - N",4CMINE _-In_r WOW- WINCOW RECE-1= ZAJN . LSa,$ SIP& PAIN MINIMUM amift) vs .,ivr To �cX ITY 0 Ft 0 K WIC - NOT IN CONTKAC7, WILA O.C.- ON C15NTER 15 2016 CGS kNTlONj RMIT CENTER (D wom r4s eAco- wc-�:,:; WA— LOD#We OETAJ- Ne 51eal H4 [Sheet Contents: MAIN FLOOK PLAN 6, 52tOULF-e Twoed: MAIN FLOOR. PLAN SYMBOLS, _ . t� ClJWO LIGMT ^� 6WCOET LIOMT HOUM1�R r-im E NATM Jb, O FLAIM Ur tT M sMr4b NW trr - Q14NNC^MAlUNTCO WIEN 5LMtk .. ' PUL+. BAf OR. JUN=oW eoK C-FOWVOMICv TYfE. CUMA.K MoOO. ICL$ . ® 0jrLET rOR CDSNSCTGN Tb &2AflIlA&4T .. ® M51M GUTL�T N +G oAlar j� N 6 1d 6MDNe o1TLr.T W Set. eon WiTFf le+hEtgR RHO, d')fit 41K PLATO' fQ crag :)XL. --T ;h f< ffi mAjuA,: 6-r6it- ;R Mitt ?MGd4W.. rlbjncTtON r . s SMlOLI ftff QW1rwi TWO SIN VLS POLE SNU17Z HES _ - Sa TMM1s6 iwy 6MAT%1'f —2.- "3ROIJND ROD GDIDUR (WtNHb)4N GEILINU ' --- CONDUIT (WINNG)IN FL@7tl .. , # MAAMVNG IhVICATM NUMBER 00 . . WR69 IBC /�bb(�EVI/�T;ONS 3 r- 0. CONDUIT oNL.y di cF.B. C WNO FAt'1 0MAUBr e5m PaxcrNG sTMA&E HeATEA FUR N%kcB • HW MDT NATER R6C.IM1GU.ATIrG, PWA? , . Utt UNIT 115ATER DECEIVED CITE' OF TUKWILA PERMIT CENTER MAIN FLOO& . PLAN fU. R,eGr.TM5 44,14° SbWME C*MP' RS IW Ak" RUNS PAA PAMPERS IBJ A 4, o1JCTs -MAT L JW." MA044M RM . RECEIVED CITY OF TUKWILA MAR 15 2016 PANEL SCNE.DULE - - PANEL We. OF N _ OR DaCAaEA HP (VA 6tau IPMF NT - - CtRCulri AMPS PEES VO L7S - - A m "2D 1.., LED 10.3 LTG >}. RECEPT3 'lime -. 1W Cn. To mu":P. .-`4.711; IjOIG .SNRFAEfL:rd475Lrr .-._ 6 2D 1 t20 SPNRE______.. ..._ ' __57VBl GAP_C.o.S ".F6VOiJ0___ � �-.._._ ..-. _ 4 40 I IM __ SPACE__._.___ --amU�lo-va.D1u:�4 s7S9uaEa 4_-D lci)c -- . - cetAoatwrJcr._ePcnea �ea+cEeon¢-rviixyxrosr-rsT� . -e. 8 20' '. ft0 S3 LTv t . _ 1 RECEPTS liRiAWATi C0170U7T1U PU116_F1p5B.1'2QL�.L'F�FI�ALI. ��UUvvllllii-- -SPA0.t 4 to I Izo - .. .. I IT --SPACE ` . I fl4fPR`i� J _- dlALi.FA�7: aW 1TYHEOhT DOOR 3:- 20 1 IZ6 - - L-lLsaai�g2.wn11�=N- swTcw' _ I I:[S - i0"' 1 ILO13.7LTGC.RFC EFTS p PANEL SP-1 'FURNISH Ec�$W STATE PP7'ItoL ' eN<rA-LLC0 0V COIPTEACTAR 4'•I'AAOYG 0 t 20 C 240 CO UN-1 _ _ _ _ PI ST VA'um 6ARE COPPER FL06R-lm BOTTOM. 1. -_ 20 2 240 1.0 FUR=l _ _ —Rpity P ISLLOW Fl609 _. i'1GQT0 SP; .. I- . 2X7._. .1_ 120... 1/!. ,.. NORTH' Wt1M1T�iil� ., IIY�e. _ o { I .'� -_ 6. _ LO .- . _I_ 120. .. SPAAE "So .:.I -'..•.. �. :_Y%7"c DlKEirsn..Trn 9 20 +-:. `. ._ .. ,. ,y :.'R-;I .�E.MiRCfLY..lIi o ~"O1'+tEJlLre._lkJwALLl" - - I ..I _ X1dC COPPiRWiia GRODUO— — __ OKI P� ObUfU_3TRAYsRTDbDIJJ3 _ - ,.':. - . L �"J/'0'1w db wP wP - - �-~ C'ADfITELD: IORSN37ARIPRTPIAC - - " • - 751i75PECT.�EF4Qi:r y�T�- M ' 173.T1t..CO'UV. L.0A0-32.S U- KVA'PA.BAS06-40040Ada-28 6.4.:4yC ulr-'/z ; ,... [j(�j�fa�. All. TIFC NADIO U)OtA CIP40UNDL MAT s _1 Itli'1` OF Y4 • I'-d I. p' 6M1i r£ SP-1Z SrtAr.1- 8G4. (BA. ra4�14�1Z®. SIC+A Bq� v =I Wle a Eh7 1W M)bte � 4' eer WITH �F° w✓�o EN�KMa4� 'a . -. .. • ® ..I:...ya r �.- :. .:r.. c:'Ca,+s:. i.. X ej, ism IM91LLe 130A, RE wrtr�i 4t E n;.:._+ I" f1R%M 1lCX�E OF .,. , wa«ve•. o ^Fisc 4 y.t _. I .. .. SFir/J.L.dE Fl.N51f _ I� ul iila.� ►'EGFR b �j,/}E 4r �.. .. e�T1eR ie) M41t!f - ' �F+zC'E5, 511X._ I. .� :•� .:� _. c.o.T+�s►•x r 3 .moi_ eSAtltf6lLO. ZTY!e IA fIMUM16 SrMu. Olt' STRIM 9-MA - "' .. .- 5-Mf% CH ryXTtJb SHAu,. 16 FftZ5Mu7C 7071 -IW f+ 4-0 . SQUAD RM. GhIlAOe I IINNIVIOgCO _ / ` (JI& A; a M-OMM al TI I I 1 -_ - - wP • uP _SIN- .5PODl PUCK HEIGHT PFR POWE¢ CO. HIND" " __ P i.M e � 1W 3-4 5OUT14 COUtT VERT rule-1 _� a � i G r9 e'X•/a uwaanmFF r:P2 N6 lFYN/i� B flSF SaA-2P I • I 9L`t M1MD BRGCBOw i'i�{Yii: ' $IDK fAe. - '- a STR .•.. a - fpP PlbkLWQW _ I 1 S _ r U oJSA Of '16NR BC^pEPRri70X,e� C�OJ-1DLL Ii•' 2 Goelti. wAi .. ES_N-1 4'X4'Xb•O' GUTTER PidIWpC2"'O `' - - - FSM-1 tfA77R[ ER//J-24oV-14 �] 'COit41c.CTeFT'4�:23' - - - -'yy. 1-6bA'2P c.a.X � 5 PI I P2 56A-2P J �•po zy NME 4 k L�aVTTe[s. S .-100A ZP LDo uor DSL. I. i "'�"�" . T1fR itum II m I '9gbJ10E W7oo(WIP , i /-FLOOR i J 1 , bn5VMeNi PLAN .. ECEIVED CITY OF TUKWILA ONE LINE DIAOMM Nb 5 2016 • PERMiT CENTER T. -Ste fti .:.J _ . I� _ -_ _. Sheet Contents: '.4 'aB7 JON �r Popoti o MN FL, 61.86+-Mj AL ursHYING. ftuER S DATA LA . DE?ACtUviENT Of�F1CC _ 5Y0CUTtt :X�UNTY �i °["� �A .ICI•inRO bQ_UILLlJt� A.1.�4. �gKING Sheet No.: WA5filNOTCN 6TIA F", 0L '..., � . A R . -C t+ 1 T G T % AgP-cyan r Drawn: ^ F it. C. MIU.BR 8 ASSO�TE5 I Job Copt.: Traced: 'I CS 'w,n.•°" . • - �Checked,' �I � \y`.• ` . Section Head: ' P,S. H, 1 R.G, RIV6R�L'JN I1E16itT5 INTP�IIQf~NC� ,1 c M E r, lit A N t CAL, 6 LS GTaI GAL _- _1�� � ; �� A�enw Director."./,/-rL Date: ..6. C IN V aD U NT[ 1. .. Wim+• kt swro t4 - Supe. of &g. A Ar ST T 'QF-WASHfNGTOIf "— DIEPARTMENT OF GEN RAL ADMINISTRATION — DIV. OF ENGINEERING & ARCHITECTURE r'ERMIT COORD COPY PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: M16-0042 DATE: 03/23/16 PROJECT NAME: WSP SOUTH KING COUNTY SITE ADDRESS: 15700 PACIFIC HWY S X Original Plan Submittal Revision # before Permit Issued Response to Correction Letter # _ Revision # after Permit Issued DEPARTMENTS: A -T AIVL qx=?q-ty KM �Ik Building Division W Fire Prevention Planning Division ❑ Public Works ❑ Structural ❑ Permit Coordinator ❑ PRELIMINARY REVIEW: DATE: 03/24/16 Not Applicable ❑ Structural Review Required ❑ (no approval/review required) REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: Approved ❑ Approved with Conditions Corrections Required ❑ (corrections entered in Reviews) Notation: DUE DATE: 04/21/16 Denied ❑ (ie: Zoning Issues) REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: w18/2013 T R S MECHANICAL INC L Home Irspahol Contact Safety & Health Claims & Insurance 001*4 Washington State Department of "Labor & Industries Page 1 of 2 Search L&I A -L Index Help Nly L&t Workplace Rights Trades & Licensing T R S MECHANICAL INC Business type Owner or tradesperson PO BOX 1315 Parent company SPANAWAY, WA 98387 Principals 253-539-0141 HAND, CLAY WILBURN, PRESIDENT PIERCE County HAND, CLAY ALLEN, VICE PRESIDENT HAND HAND, SANDRA JOY, SECRETARY CLAY W HAND; Doing business as T R S MECHANICAL INC WA UBI No. Business type 602 244 048 Corporation Parent company Governing persons ENERGY SYSTMS MNGMT/TRS INC CLAY Effective — expiration A 01/2712003— 02/09/2017 HAND Bond CLAY W HAND; CBIC SANDRA J HAND; License Verify the contractor's active registration / license / certification (depending on trade) and any past violations. Construction Contractor _....................................................................... . Active. Effective date Meets current requirements. License specialties GENERAL $1,000,000.00 License no. TRSMEI*977B7 Effective — expiration Effective date 01/2712003— 02/09/2017 12/04/2012 Bond Expiration date CBIC $12,000.00 Bond account no. LB9870 Received by L&I Effective date 06/13/2006 01/22/2006 Expiration date Until Canceled Insurance ............ _............... Continental Western Ins Co $1,000,000.00 Policy no. cwp2960301 Received by L&I Effective date 11/06/2015 12/04/2012 Expiration date 12/04/2016 Insurance history Savings https://secure.Ini.wa.gov/verify/Detail.aspx?UBI=602244048&LIC=TRSMEI*977B7&SAW= 4/12/2016