Loading...
HomeMy WebLinkAboutPermit M16-0046 - SPECTRA - DUCTWORK AND GRILLES / DIFFUSERSSPECTRA 17620 W VALLEY E[Vv7Tf M16-0046 City of Tukwila • Department of Community Development • 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-438-9350 Web site: http://www.TukwilaWA.gov Parcel No: 2523049017 Address: 17620 W VALLEY HWY Project Name: SPECTRA MECHANICAL PERMIT Permit Number: M16-0046 Issue Date: 4/28/2016 Permit Expires On: 10/25/2016 Owner: 2012 National Electrical Code: Name: TERRENO 17600 WVH LLC 2012 Address: 101 MONTGOMERY ST #200, SAN International Mechanical Code Edition: 2012 FRANCISCO, WA, 94104 2014 Contact Person: 2012 WA State Energy Code: Name: ALEX BURKHART Phone: (206) 763-1744 Address: 727 S KENYON ST, SEATTLE, WA, 98108 Contractor: Name: EVERGREEN REFRIGERATION LLC Phone: (206) 763-1744 Address: 727 S KENYON ST, SEATTLE, WA, 98108 License No: EVERGRL954R2 Expiration Date: 1/6/2018 Lender: Name: Address: DESCRIPTION OF WORK: INSTALLATION OF DUCTOWRK AND GRILLES/DIFFUSERS Valuation of Work: $2,623.00 Type of Work: Fuel type: Fees Collected: $233.88 Electrical Service Provided by: PUGET SOUND ENERGY Water District: RENTON Sewer District: RENTON SEWER SERVICE Current Codes adopted by the City of Tukwila: International Building Code Edition: 2012 National Electrical Code: 2014 International Residential Code Edition: 2012 WA Cities Electrical Code: 2014 International Mechanical Code Edition: 2012 WAC 296-46B: 2014 Uniform Plumbing Code Edition: 2012 WA State Energy Code: 2012 International Fuel Gas Code: 2012 Permit Center Authorized Signature: &MU WMC Date: �Iwi 1 I hearby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this development permit and agree to the conditions attached to this permit. ' r Signature:_ v Date: `C l Print Name: �'\`�j°✓� This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: Work shall be installed in accordance with the approved construction documents, and any changes made during construction that are not in accordance with the approved construction documents shall be resubmitted for approval. 2: All permits, inspection record card and approved construction documents shall be kept at the site of work and shall be open to inspection by the Building Inspector until final inspection approval is granted. 3: All construction shall be done in conformance with the Washington State Building Code and the Washington State Energy Code. 4: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of this requirement. S: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center. 6: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 7: ***MECHANICAL PERMIT CONDITIONS*** 8: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431-3670). 9: Manufacturers installation instructions shall be available on the job site at the time of inspection. PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 1800 MECHANICAL FINAL 0609 PIPE/DUCT INSULATION 0701 ROUGH -IN MECHANICAL CITY OF TUKWILA Community Development Department • Permit Center • 6300 Southcenter Blvd., Suite 100 Tulovila, WA 98188 http://www.TukwilaWA..Pov Mechanical Permit No. Project No. Date Application Accepted: Date Application Expires: or office use only) MECHANICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. "please print" SITE LOCATION Q rr `' i � ,, - 11. - King Co Assessor's Tax No.: 7i5Z 3 04. - L b i� Site Address:_ 1-_q ZD Qy aV �1 �C�`�t Suite Number: Floor: TenantName: New Tenant: ❑ .....Yes ❑ ..No PROPERTY OWNER Name: i,, ,,.i7 t-I,6bJ 1,/ V IA l—t-C Address: Lo /A&+A phJ` City: �` rSi� State. /J Zip:jcl CONTACT PERSON — person receiving all project communication Name:&!?� rl�t)'3cr� Address: I V� � � V� •ti S'� . City: State: Zip:4gCJy Phone:U6 �� _ 1-1+4- Fax: Ufa 3-23 &,I Email:�l` e y��✓aLG-GflV'tp Valuation of project (contractor's bid price): $ 2 1-G -3 . Describe the scope of work in detail: MECHANICAL CONTRACTOR INFORMATION Company Name: Address: City: S6AI� State: Zip: I Phone: -Ur. --JC3 ,_ (- qk4 Fax: U6 7,(; 3 —�3�c� Contr Reg No.: FvE(t6—p-q sq(Z,,xp Date: t' 6 /it Tukwila Business License No.: Use: Residential: New .......... ❑ Replacement ........ ❑ Commercial: New .......... ❑ Replacement ........ ❑ Fuel Type: Electric..... ❑ Gas ....... ❑ Other: H:Applications\Forms-Applications On Line\2016 ApplicationsWechanical Permit Application Revised 14-16.do" Revised: January 2016 Page I of 2 bh 0 r J i Indicate type of mechanical work being installed and the quantity below: Unit Type Qty Furnace <100k btu Residential, Nighttime Furnace >I 00k btu Industrial Floor furnace 55 dB(A) Suspended/wall/floor mounted heater 57 dB(A) Appliance vent Commercial Repair or addition to heat/refrig/cooling system 47 dB(A) Air handling unit <10,000 cfm 65 dB(A) Unit Type Qty Air handling unit >10,000 cfm Residential, Nighttime Evaporator cooler Industrial Ventilation fan connected to single duct 55 dB(A) Ventilation system 57 dB(A) Hood and duct Commercial Incinerator — domestic 47 dB(A) Incinerator — comm/industrial 65 dB(A) Unit Type Qty Fire damper Residential, Nighttime Diffuser Industrial Thermostat 55 dB(A) Wood/gas stove 57 dB(A) Emergency enerator Commercial Other mechanical equipment 47 dB(A) 60 dB(A) 65 dB(A) Boiler/Compressor Qty 0-3 hp/100,000 btu 3-15 h /500,000 btu 15-30 hp/1,000,000 btu 30-50 hp/1,750,000 btu 50+ hp/1,750,000 btu Noise: Mechanical units need to be in compliance with the Tukwila Noise Code. Maximum permissible sound levels are based on from where the sound is created and where the sound is heard. Additionally, if sound can be heard from within a house at night in a residential zone it may not be allowed. For more details. see TMC 8.22 District of Sound Producing Source District of Receiving Property Residential, Daytime* Residential, Nighttime Commercial Industrial Residential 55 dB(A) 45 dB(A) 57 dB(A) 60 dB(A) Commercial 57 dB(A) 47 dB(A) 60 dB(A) 65 dB(A) Industrial 60 dB(A) 50 dB(A) 65 dB(A) 70 dB(A) *Daytime means 7AM-1 OPM, Monday through Friday and 8AM-1 OPM, Saturday, Sunday and State -recognized holidays. A few sounds are exempt from the noise code, including: Warning devices; Construction and property maintenance during the daytime hours (7am-10pm); Testing of backup generators during the day. PERMIT APPLICATION NOTES - Value of construction — in all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the permit center to comply with current fee schedules. Expiration of plan review — applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The building official may grant one extension of time for additional periods not to exceed 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR AUTHORIZED AGENT: Signature:" Date: (t�-- Print Name: ' r-� Day Telephone: Mailing Address: Z� Cw"'Y,�'t 5� City State Zip B:\Applications\Forms-Applications On Line\2016 ApplicationsWechanical Permit Application Revised 14.16.docx Revised: January 2016 Page 2 of 2 bh DESCRIPTIONS PermitTRAK ACCOUNT QUANTITY PAID $233.88 M16-0046 Address: 17620 W VALLEY HWY Apn: 2523049017 $233.88 MECHANICAL $224.88 PERMIT ISSUANCE BASE FEE R000.322.100.00.00 0.00 $32.50 PERMIT FEE R000.322.100.00.00 0.00 $147.40 PLAN CHECK FEE R000.322.102.00.00 0.00 $44.98 TECHNOLOGY FEE $9.00 TECHNOLOGY FEE TOTAL+ R8029 R000.322.900.04.00 0.00 $9.00 Date Paid: Monday, March 28, 2016 Paid By: EVERGREEN REFRIGERATION Pay Method: CHECK 007822 Printed: Monday, March 28, 2016 10:08 AM 1 of 1 SYSTEMS If -+R INSPECTION RECORD Retain a copy with permit f d ` 6d7Yc SPECTI PERMIT N0. CITY OF TUKWILA BUILDING I 6300 Southcenter Blvd., #100, Tukwila. WA 98188 j1446+ Permit Inspection Request Line (206) 438-9350 /"` Project: Type Insp�ctin, r LIR Add 9 zo a f (Q a e Date Called: Special Instructions: Date wanted: a.m. p.m. Requester: Phone No: (Inspector: j IDate:v /'c El REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. 349 INSPECTION RECORD Retain a copy with permit jqjC-0cqk INSPECTION N0. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project��t ( Type gfinspestion:; Add ess: Date Called: Special. Instructions: Date Wanted: a.m. r Z'p.m. R quester* I 0 Pine3� Inspector: Date— El REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. ,,' . r EVERGREEN REFRIGERATION, LLC AIR OUTLET TEST REPORT - SUPPLY Project: 5�eei-r-CN Job #: Date: —44/00_..._ ®Area Served LBEMMM M�Em ®® =�Mmm_ �r_t. RIM.� __-_mmm� __-_____ -_-_____ -_-_____ __-_____ -_-_____ PERMIT COORD COPY PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: M16-0046 DATE: 04/01/16 PROJECT NAME: SPECTRA SITE ADDRESS: 17620 W VALLEY HWY X Original Plan Submittal Response to Correction Letter # Revision # before Permit Issued Deferred Submittal # after Permit Issued DEPARTMENTS: AY- c, "P Building Division 10 Fire Prevention ® Planning Division ❑ Public Works ❑ Structural ❑ Permit Coordinator ❑ PRELIMINARY REVIEW: DATE: 04/05/16 Not Applicable ❑ Structural Review Required ❑ (no approval/review required) REVIEWER'S INITIALS: APPROVALS OR CORRECTIONS: Approved a Corrections Required ❑ (corrections entered in Reviews) Notation: DATE: DUE DATE: 05/03/16 Approved with Conditions Denied ❑ (ie: Zoning Issues) REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: 12/18/2013 EVERGREEN REFRIGERATION T T,C Hoene i:spanol Contact Safety & Health Claims & Insurance inWashington State Department of Labor & Industries EVERGREEN REFRIGERATION LLC Owner or tradesperson 727 S KENYON ST 602 512 953 SEATTLE, WA 98108 Principals 206-763.1744 PATTON, RODGER, PARTNER/MEMBER KING County PATTON, MATTHEW, PARTNER/MEMBER A Patton, Adam, PARTNER/MEMBER PATTON Patton, Douglas, PARTNER/MEMBER MATTHEW PATTON; EVERGREEN REFRIGERATION RODGER PATTON; LLC, PARTNER/MEMBER PATTON, DAVID, PARTNER/MEMBER Construction Contractor ............. (End: 01/21/2014) Doing business as EVERGREEN REFRIGERATION LLC Page I of 3 Search L&I %7 A -Z, Index Help M; L&I Workplace Rights Trades & Licensing WA UBI No. Business type 602 512 953 Limited Liability Company Governing persons DAVID A PATTON MATTHEW PATTON; RODGER PATTON; License Verify the contractor's active registration / license / certification (depending on trade) and any past violations. Construction Contractor ............. Active. Meets current requirements. License specialties GENERAL License no. EVERGRL954R2 Effective — expiration 01/06/2006— 01/06/2018 Bond Merchants Bonding Co (Mutual) $12,000.00 Bond account no. WA15097 Received by L&I Effective date 12115/2011 01101/2012 Expiration date Until Canceled Bond history Insurance .............................. Nationwide Mutual Ins Co $1,000,000.00 Policy no. ACP 3007246151 https:Hsecure.Ini.wa.gov/verify/Detail.aspx?UBI=602512953&LIC=EVERGRL954R2&SAW= 4/27/2016 a .. 1 . ........ .. .... .. :.� .. ........ ...:. ,j :::.... ,... -ti... , .o- :..fir. .. . x E.... ..:.:. .. .. .:.. . .. ... ::....... ... . �. z r' ........ ,.,. fir ::. ..... . .: ..... .:. ..,.. ...... _ . j _... t .., ., SV7 t %.dt.F'•et.l..^e ECS F.C. ' 29.s o t a ail 1lilli z CCIO Da O1rd!I?il� F,igg �( v icc( 1p i3,0 Co and t� ctPCI( Ci";S ES I;?ckf'IOIEB��Sa By:, Dain:City Of Tuk `' ? a BUILDING DIVISION GENERAL A NOTES.. DUCTWORK 1.1 ALL DUCT DIMENSIONS NSIONS ON PLAN ARE CLEAR INSIDE DIMENSIONS, ADD 2" TO EACH DIMENSION TO OBTAIN OUTSIDE DIMENSION. ADD 4" TO EACH DIMENSION IF DUCTWORK IS ON THE EXTERIOR OF. BUILDING. 1.2 THE FIRST NUMBER ON ALL DUCT DIMENSIONS IS THE WIDTH AND THE SECOND NUMBER IS THE HEIGHT. 1.3 MATERIALS WITHIN HIN DUCTS OR PLENUMS SHALL HAVE A FLAME SPREAD RATING LESS THAN 25 AND A FLAME SMOKE DEVELOPMENT RATING LESS THAN 50, PER IMC 602.2.1. 1.4 SEAL ALL TRANSVERSE JOINTS FOR DUCTWORK WITH STATICPRESSURE BETWEEN 1/2 INCHES AND 2 INCHES. DUCTWORK WHICH IS DESIGNEDO T OPERATE AT PRESSURES ABOVE 1/2 INCH WATER COLUMN STATIC PRESSURE SHALL BE SEALED IN ACCORDANCE WITH STANDARD RS -7 1.5 ALL DUCT GAUGES PER SMACNA IMC 603-4. 1.6 ALL DUCT SUPPORTS PER , SMACNA IMC 603-10. 1.7 DIFFUSERS ATTACH C I FUSERS AND GRILLES S TO T -BAR GRID PER WA STATE &LOCAL CODES. 1.8 BALANCING DAMPERS ARE TO BE INSTALLED ON ALL BRANCH DUCTS OR DIFFUSERS. INSULATION 2.1 INSULATE OR LINE DUCTWORK PER WA. STATE ENERGY AND MECHANICAL CODES. 2.2: INSULATE REFRIGERANT & CONDENSATE PIPING PER STATE & LOCAL ENERGY CODES. GENERAL CONTRACTOR 3.1 GENERAL CONTRACTOR TO PROVIDE AND CUT OPENINGS FOR ALL ROOFTOP, CEILING, FLOOR, AND WALL PENETRATIONS, INCLUDING WEATHERPROOF SEALING AND FIRE PROOF LINING PER IMC & IBC. , 3.2 GENERAL CONTRACTOR TO VERIFY PENETRATION LOCATION AND DIMENSIONS WITH ERL BEFORE FRAMING OPENINGS. 3.3 GENERAL CONTRACTOR TO PROVIDE ALL DEMOLITION, PATCHING, AND PAINTING AS REQUIRED FOR MECHANICAL WORK. 3.4 GENERAL CONTRACTOR TO PROVIDE ADEQUATE STRUCTURAL SUPPORT AS REQUIRED FOR MECHANICAL WORK. 3.5 GENERAL CONTRACTOR TO PROVIDE ADEQUATE ENGINEERING AS REQUIRED FOR MECHANICAL WORK. 3.6 GENERAL CONTRACTOR TO PROVIDE SERVICE ACCESS PER CODE TO ALL MECHANICAL EQUIPMENT. - 3.7 GENERAL CONTRACTOR TO LEVEL ALL FACTORY CURBS PROVIDED BY ERL PROVIDE ALL CANT STRIPS AND CURB INSULATION, AND SEAL AGAINST LEAKS. 3.8 GENERAL CONTRACTOR TO PROVIDE ALL CUTTING AND PATCHING OF T -BAR CEILING AS REQUIRED FOR HVAC INSTALLATION. . 3.9 GENERAL CONTRACTOR TO PROTECT ALL OPENINGS THROUGH FLOORS PROVIDED FOR DUCTWORK INSTALLATION IN ACCORDANCE WITH TABLE 601 OF INTERNATIONAL BUILDING CODE, WHERE REQUIRED BY SECTION 707 OF IBC. ELECTRICAL 4.1 ERL TO INSTALL ALL LOW VOLTAGE CONTROL WIRING, CONDUIT WILL BE PROVIDED BY ELECTRICAL CONTRACTOR. 4.2 ELECTRICAL CONTRACTOR TO PROVIDE ALL ELECTRICAL CONNECTIONS, DISCONNECTS, AND STARTERS FOR MECHANICAL EQUIPMENT. 4.3 ELECTRICAL CONTRACTOR TO VERIFY EQUIPMENT SIZES, LOADS AND LOCATIONS WITH ERL MECHANICAL PLAN AND WITH FIELD CONDITIONS. 4.4 ELECTRICAL CONTRACTOR TO INTERLOCK BATHROOM EXHAUST FANS WITH LIGHT SWITCH. 4.5 ERL TO PROVIDE 7 -DAY NIGHT SETBACK, PROGRAMMABLE TYPE T -STAT WITH CAPABILITY OF 5°F DEADBAND. 4.6 ERL TO VERIFY FINAL LOCATION OF THERMOSTAT WITH CUSTOMER. 4.7 ELECTRICAL CONTRACTOR TO PROVIDE ELECTRICAL GCFI OUTLET WITHIN 25 FT OF EACH PIECE OF MECHANICAL EQUIPMENT. PLUMBING 5.1 PLUMBING CONTRACTOR TO FURNISH AND INSTALL ALL GAS PIPING FOR MECHANICAL EQUIPMENT PER CODE. 5.2 PLUMBING CONTRACTOR OFFSET VENTS 10 FEET MINIMUM FROM ALL HVAC FRESH AIR INTAKES OR 2' ABOVE HIGHEST POINT OF INTAKE, IMC 401.4.1. 5.3 CONDENSATE DRAINS FROM RTU BY ERI TO DRAIN WITHIN 12" OF UNIT. CONDENSATE DRAINS FOR AIR HANDLERS BY PLUMBER. ENERGY CODE COMPLIANCE 6.1 THE SUPPLY HEATING AND COOLING ENERGY TO EACH ZONE SHALL BE CONTROLLED BY INDIVIDUAL THERMOSTATIC CONTROLS CAPABLE OF RESPONDING TO TEMPERATURE WITHIN THE ZONE. AT A MINIMUM, EACH FLOOR SHALL BE CONSIDERED AS A SEPARATE ZONE 6.2 OUTDOOR AIR SUPPLY, EXHAUST OPENINGS AND RELIEF OUTLETS FOR EQUIPMENT GREATER THAN 300 CFM SHALL BE PROVIDED WITH CLASS 1A MOTORI7_ED DAMPERS WHICH CLOSE AUTOMATICALLY WHEN THE SYSTEM IS OFF PER WSEC/SEC SECTION C402.4.5.2. MECHANICAL CODE COMPLIANCE 7.1 WHERE REQUIRED PROVIDE AUTOMATIC SHUTOFF ACTIVATED BY SMOKE DETECTORS IN EACH SYSTEM DELIVERING HEATING OR COOLING AIR IN EXCESS OF 2000 CFM. DETECTORS SHALL BE LOCATED IN THE MAIN RETURN AIR PER IMC 606. WA2012 �� ,�1::t u'h:ca ALL COMMISSIONING OF HEATING, VENTILATION AND AIR CONDITIONING' SYSTEMS AS L4't'lUiribjil REQUIRED BY SECTION C408 'SYSTEM COMMISSIONING' OF THE 2012 WASHINGTON STATE i ,-��- ENERGY CODE (WSEC):SHALL BE PERFORMED BY EVERGREEN REFRIGERATION, LLC. THE t.Id-dos PipbV ACTIVITIES TO BE ACCOMPLISHED ARE PER THE SECTIONS LISTED IN THE 'COMMISSIONING COMPLIANCE CHECKLIST' SHOWN BELOW. AT THE COMPLETION OF THE Ch- Of Tukwila ACTIVITIES REQUIRED FOR COMMISSIONING AS DEFINED BY SECTI❑N C408 OF WSEC iLipl^4 i f DIVISIO� THE 'COMMISSIONING COMPLIANCE CHECKLIST' WILL BE REVIEWED WITH THE BUILDING OWNER OR THE OWNER'S REPRESENTATIVE AND THIS CERTIFICATI❑N WILL BE SIGNED AND DATED. THIS WILL SATISFY TO THE CODE OFFICIAL THAT THE REPORT - --- =- - ------ ---- ------ HAS BEEN ACCEPTED AS REQUIRED BY SECTI❑N C408121 OF WSEC. - - - -- _ rn-, _---- - -- - - - - - - - _ _ _ _ _ (N) U I FLC�- I ulil ---O FFI 6 �- - - - - - --- (N) _ COMMISSIONING COMPLIANCE CHECKLIST -- = i , --- � ------ - - - I------ ------ - -- -- - - -- I Project \� CG -1 CG -1 CG -1 I Information I -Wr 11- 811 811 REVIEWED FOR CODE COMPLIANCE APPROVED APR 2 5 2016 1� `Clfy of iukwl a BUILDING DIVISION Project Name: Project Address: Commissioning Authority: Commissioning ❑ Plan Commissioning Plan was used during construction and Included Items below (Section . A nvmtfve descrptbn of ac*Atles and the personnel Intended to accomplish each one C408.1.1) • Measurable criteria for performance • rweJons to be tested Systems Balancing Systems Balancing has been completed (Section • Alr and Hydronlc systems are proportionately balanced In a manner to first *Me throttling losses C408.2.2) • . Test ports are provided on each pump for measuring pressor moss the p V Functional Testing (Sections C408.2.3) HVAC Equipment Functional Testing has been completed (Section C408.2.3.1) HVAC equipmfgnt has been tested to demonstrate the Installation and operation o components, systems and system -by -system Interfacing relationships In accordance with approved lans and specifications HVAC Controls Functional Testing has been completed (Section C408.2.3.2) HVppC ontrol h ve bee tested to ensure that control devices are call ro. ed, aci'Jus; ed an ar operate properly. Se�uence of o�p�iotion Rive been functionally tested to ensure they pp, ; and saecfficn!ions approved OEconomizers Functional Testing has been completed (Section C408.2.3.3) Economizers operate In accordance with manufacturer's specifications Supporting O Documents Manuals, record documents and training have been completed or are scheduled (S2CtlOr1 • System documentation has been provided to the omer or scheduled datet 0408.1.3.2) • Record daaeuents have been sullnitted to owner or scheduled datet • Trohtg has been completed or scheduled date' Commissioning Report (Section C408.1.2) I hereby .certify that all requirements for Commissioning have been completed In accordance with the Washington State Energy Code, Certification Including all Items above. Buldrig s tnthre`,i Dote d NOT PUBLISHED. ALL RIGHTS RESERVED. THE DRAWING AND SPECIFICATIONS IDEAS DESIGNS AND ARRANGEMENTS ANGENENTS R P NT R E MESE ED THEREBY ARE AND SHALL REMADJ THE PROPERTY OF EVE- RGREEN REFRIGERATION INC. NO PART THEREOF SHALL BE R - EPRDDUC D LOSED DR DISTRIBUTEE TO OTHERS, OLD, PUB- LISHED DR OTHERWISE USED WITHOUT THE PRIOR WRITTEN C DNSENT T AND APPROPRIATE DMPE C N- SATI ON T V D EVERGREEN REFRIGERATION INC. VISUAL CON TACT VITH THE ABOVE DRAWINGS DR SPECIFIC- ATIONS SHALL CONSTITUTE CONCLUSIVE EVIDENCE OF AC CEPT ANCE OF THESE RESTRICTIONS. N N 100 00 0 LLl W U.) F- N - i- I-- a a 1 D 0 N I -L N Z O H F_ U LLI F - Z CE Z M _J O ryW 0 J CD LJ m N w V) C:) V) V) Q El 00 C) 00 0 (DZ 1 X W W 00 Q W = 00 LuIr- W = i- 00 U U) W c) Lel. � J Q p Q� O Q z 0c) IL i . D REVISIONS p NO DATE ' ITEM. N J RECEIVED CITY OF TUKWILA MAR 2 8 2016 W PERMIT CENTER DWG. BY: GN CHK. BY: MG AM JOB. NO.: 415301 SHEET: