Loading...
HomeMy WebLinkAboutPermit M16-0048 - PEARLE VISION - DUCTWORK, DIFFUSERS AND CONTROLSPEARLS VISION 17250 SOUTHCENTER PKWY SUITE 128 ITI f[�1ZIP�:? City of Tukwila Department of Community Development • 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-438-9350 Web site: http://www.TukwilaWA.Rov MECHANICAL PERMIT Parcel No: 7888920020 Permit Number: M16-0048 Address: 17250 SOUTHCENTER PKWY 128 Issue Date: 5/23/2016 Permit Expires On: 11/19/2016 Project Name: PEARLE VISION Owner: Name: WIG PROPERTIES LLC -SS National Electrical Code: Address: 4811 134TH PL SE, BELLEVUE, MN, 2012 WA Cities Electrical Code: 98006 International Mechanical Code Edition: Contact Person: WAC 296-46B: 2014 Name: TIM SCHENK Phone: (952) 345-6040 Address: 1120 E 80 ST #211, BLOOMINGTON, 2012 MN, 55420 Permit Center Authorized Signature:W_,� Contractor: Date: ��- Name: LAKEVIEW CONSTRUCTION INC Phone: (414) 657-4222 Address: 10505 CORPORATE DR #200, PLEASANT PRAIRIE, WI, 53158 License No: LAKEVC1072KC Expiration Date: 1/13/2017 Lender: Name: Address: DESCRIPTION OF WORK: EXISTING RTU'S TO REMAIN. NEW DUCTWORK, DIFFUSERS AND CONTROLS Valuation of Work: $18,000.00 Fees Collected: $428.80 Type of Work: NEW Electrical Service Provided by: PUGEST SOUND ENERGY Fuel type: GAS Water District: TUKWILA Sewer District: TUKWILA Current Codes adopted by the City of Tukwila: International Building Code Edition: 2012 National Electrical Code: 2014 International Residential Code Edition: 2012 WA Cities Electrical Code: 2014 International Mechanical Code Edition: 2012 WAC 296-46B: 2014 Uniform Plumbing Code Edition: 2012 WA State Energy Code: 2012 International Fuel Gas Code: 2012 Permit Center Authorized Signature:W_,� Date: ��- I hearby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate r cancel the provisions of any other state or local laws regulating construction or the performance o�w ! am authorized to sign and obtain this development permit ree to the conditions attache his permit. Signature: ' Date: )Z L Print Na This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: Work shall be installed in accordance with the approved construction documents, and any changes made during construction that are not in accordance with the approved construction documents shall be resubmitted for approval. 2: All permits, inspection record card and approved construction documents shall be kept at the site of work and shall be open to inspection by the Building Inspector until final inspection approval is granted, 3: All construction shall be done in conformance with the Washington State Building Code and the Washington State Energy Code. 4: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of this requirement. 5: Every occupied space other than enclosed parking garages and buildings used for repair of automobiles shall be ventilated in accordance with the applicable provisions of the International Mechanical Code. 6: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206-431-3670). 7: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center. 8: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 9: `MECHANICAL PERMIT CONDITIONS' 10: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431-3670). 11: Manufacturers installation instructions shall be available on the job site at the time of inspection. PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 1800 MECHANICAL FINAL 0609 PIPE/DUCT INSULATION 0701 ROUGH -IN MECHANICAL City of Tukwila ' Department of Community Development + 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-438-9350 Web site: http://www.TukwilaWA.eov MECHANICAL PERMIT Parcel No: 7888920020 Permit Number: M16-0048 Address: 17100 SOUTHCENTER PKWY 128 Issue Date: 5/23/2016 Permit Expires On: 11/19/2016 Project Name: PEARLE VISION Owner: 2012 National Electrical Code: Name: WIG PROPERTIES LLC -SS 2012 Address: 4811134TH PL SE, BELLEVUE, MN, International Mechanical Code Edition: 2012 98006 2014 Contact Person: 2012 WA State Energy Code: Name: TIM SCHENK Phone: (952) 345-6040 Address: 1120 E 80 ST #211, BLOOMINGTON, �/� MN, 55420 Contractor: Name: LAKEVIEW CONSTRUCTION INC Phone: (414) 657-4222 Address: 10505 CORPORATE DR #200, PLEASANT PRAIRIE, WI, 53158 License No: LAKEVC1072KC Expiration Date: 1/13/2017 Lender: Name: Address: DESCRIPTION OF WORK: EXISTING RTU'S TO REMAIN. NEW DUCTWORK, DIFFUSERS AND CONTROLS Valuation of Work: $18,000.00 Fees Collected: $428.80 Type of Work: NEW Electrical Service Provided by: PUGEST SOUND ENERGY Fuel type: GAS Water District: TUKWILA Sewer District: TUKWILA Current Codes adopted by the City of Tukwila: International Building Code Edition: 2012 National Electrical Code: 2014 International Residential Code Edition: 2012 WA Cities Electrical Code: 2014 International Mechanical Code Edition: 2012 WAC 296-466: 2014 Uniform Plumbing Code Edition: 2012 WA State Energy Code: 2012 International Fuel Gas Code: 2012 �/� < Permit Center Authorized Signature:(, Date: I hearby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the perform work. I am authorized to sign and obtain this development per and a ree to the c ed to this permit. Signature- ' Date: IL Print me:_ Li%e1 ' D _0Vti-s23 This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: Work shall be installed in accordance with the approved construction documents, and any changes made during construction that are not in accordance with the approved construction documents shall be resubmitted for approval. 2: All permits, inspection record card and approved construction documents shall be kept at the site of work and shall be open to inspection by the Building Inspector until final inspection approval is granted. 3: All construction shall be done in conformance with the Washington State Building Code and the Washington State Energy Code. 4: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of this requirement. 5: Every occupied space other than enclosed parking garages and buildings used for repair of automobiles shall be ventilated in accordance with the applicable provisions of the International Mechanical Code. 6: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206-431-3670). 7: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center. 8: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 9: ***MECHANICAL PERMIT CONDITIONS*** 10: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431-3670). 11: Manufacturers installation instructions shall be available on the job site at the time of inspection. PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 1800 MECHANICAL FINAL 0609 PIPE/DUCT INSULATION 0701 ROUGH -IN MECHANICAL CITY OF TUKWA Community Development Department Permit Center • 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 " http://www.Tukwi]aWA.gov SITE LOCATION Mechanical Permit No. m C (� &Ioqk Project No. Date Application Accepted: 0 -5 I'm Date Application Expires: 0� 12/1(e use MECHANICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **please print** Site Address: 17100 Southcenter Parkway Tenant Name: Pearle Vision PROPERTY OWNER Name: WIG Properties, LLC Address: 4811 134th. Place S.E. City: Bellevue State: WA Zip: 98006 CONTACT PERSON — person receiving all project communication Name: Tim Schenk Address: 1120 E. 80th. Street, Suite 211 City: Bloomington State: MN Zip: 55420 [Email..hone: (952) 345-6040 Fax: (952) 854-4909 tims@elderjones.com Valuation of project (contractor's bid price): $ t`8,000 , QL1 Describe the scope of work in detail: King Co Assessor's Tax No. Suite Number: 128 :::• 11 1 Floor: I New Tenant: 0 .....Yes ❑..No MECHANICAL CONTRACTOR INFORMATION Company Name: T.B.D. Address: City: State: Zip: Phone: Fax: Contr Reg No.: Exp Date: Tukwila Business License No.: Exisiting RTU's to remain. New ductwork, diffusers and controls. Use: Residential: New .......... ❑ Replacement ........ ❑ Commercial: New .......... J2 Replacement ........ ❑ Fuel Type: Electric..... ❑ Gas ....... 0 Other: RTU's are exisiting to remain 1-IMpplicalionsTomu-Applications On Line\2016 ApplicationsWechanical Permit Application Revised 1-0-16.doex Rcvised: January 2016 Pagel of 2 bh Indicate type of mechanical work being installed and the quantity below: Unit Type Qty Furnace <100k btu Residential, Nighttime Furnace >I 00k btu 39 Floor furnace 2 Suspended/wall/floor mounted heater 57 dB(A) Appliance vent Commercial Repair or addition to heat/refrig/cooling system 47 dB(A) Air handling unit <10,000 cfm 65 dB(A) Unit Type Qty Air handling unit >I0,000 cfm Residential, Nighttime Evaporator cooler 39 Ventilation fan connected to single duct 2 Ventilation system 57 dB(A) Hood and duct Commercial Incinerator — domestic 47 dB(A) Incinerator — comm/industrial 65 dB(A) Unit Type Qty Fire damper Residential, Nighttime Diffuser 39 Thermostat 2 Wood/gas stove 57 dB(A) Emergency enerator Commercial Other mechanical equipment 47 dB(A) 60 dB(A) 65 dB(A) Boiler/Compressor Qty 0-3 hp/100,000 btu 3-15 h /500,000 btu 15-30 hp/1,000,000 btu 30-50 hp/1,750,000 btu 50+hp/1,750,000 btu Noise: Mechanical units need to be in compliance with the Tukwila Noise Code. Maximum permissible sound levels are based on from where the sound is created and where the sound is heard. Additionally, if sound can be heard from within a house at night in a residential zone it may not be allowed. For more details, see TMC 8.22 District of Sound Producing Source District of Receiving Property Residential, Daytime* Residential, Nighttime Commercial Industrial Residential 55 dB(A) 45 dB(A) 57 dB(A) 60 dB(A) Commercial 57 dB(A) 47 dB(A) 60 dB(A) 65 dB(A) Industrial 60 dB(A) 50 dB(A) 65 dB(A) 70 dB(A) *Daytime means 7AM-1 OPM, Monday through Friday and 8AM-1 OPM, Saturday, Sunday and State -recognized holidays. A few sounds are exempt from the noise code, including: Warning devices; Construction and property maintenance during the daytime hours (lam -I Opm); Testing of backup generators during the day. PERMIT APPLICATION NOTES - Value of construction — in all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the permit center to comply with current fee schedules. Expiration of plan review — applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The building official may grant one extension of time for additional periods not to exceed 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR AUTHORIZED AGENT: Print Name: Tim Schenk Date: 03/28/2016 Day Telephone: (952) 345-6040 Mailing Address: 1120 E 80th. Street, Suite 211 Bloomington MN 55420 City State Zip HAApplicationsTorms-Applications On Linc\2016 Applicalions%Mcchanical Permit Application Revised 14-16.docx Revised: January 2016 bh Page 2 of 2 DESCRIPTIONS ACCOUNT QUANTITY PermitTRAK PAID $2,444.46 D16-0085 Address: 17100 SOUTHCENTER PKWY 128 Apn: 7888920020 $2,011.16 DEVELOPMENT $1,915.60 PERMIT FEE R000.322.100.00.00 0.00 $1,911.10 WASHINGTON STATE SURCHARGE B640.237.114 0.00 $4.50 TECHNOLOGY FEE $95.56 TECHNOLOGY FEE R000.322.900.04.00 0.00 $95.56 M16-0048 Address: 17100 SOUTHCENTER PKWY 128 Apn: 7888920020 $346.34 MECHANICAL $329.85 PERMIT ISSUANCE BASE FEE R000.322.100.00.00 0.00 $32.50 PERMIT FEE R000.322.100.00.00 0.00 $297.35 TECHNOLOGY FEE $16.49 TECHNOLOGY FEE R000.322.900.04.00 0.00 $16.49 PG16-0045 Address: 17100 SOUTHCENTER PKWY 128 Apn: 7888920020 $86.96 PLUMBING $77.88 PERMIT ISSUANCE BASE FEE R000.322.100.00.00 j 0.00 $32.50 PLAN CHECK FEE R000.322.103.00.00 0.00 $45.38 TECHNOLOGY FEE $9.08 TECHNOLOGY FEE R000.322.900.04.00 TOTAL 0.00 $9.08 Date Paid: Monday, May 23, 2016 Paid By: LAKEVIEW CONSTRUCTION INC Pay Method: CHECK 43516 Printed: Monday, May 23, 2016 7:40 AM 1 of 1 r"[ i ' f � � 1 SYSTEMS DESCRIPTIONS PermitTRAK PAID $2,037.85 D16-0085 Address: 17100 SOUTHCENTER PKWY 128 Apn: 7888920020 $1,242.22 DEVELOPMENT $1,242.22 PLAN CHECK FEE R000.345.830.00.00 0.00 $1,242.22 EL16-0275 Address: 17100 SOUTHCENTER PKWY 128 Apn: 7888920020 $564.17 ELECTRICAL $537.30 PERMIT FEE MULTI-FAM/COMM R000.322.101.00.00 0.00 $537.30 TECHNOLOGY FEE $26.87 TECHNOLOGY FEE R000.322.900.04.00 0.00 $26.87 M16-0048 Address: 17100 SOUTHCENTER PKWY 128 Apn: 7888920020 $82.46 MECHANICAL $82.46 PLAN CHECK FEE R000.322.102.00.00 0.00 $82.46 PG16-0045 Address: 17100 SOUTHCENTER PKWY 128 Apn: 7888920020 $149.00 PLUMBING $149.00 PERMIT FEE R000.322.100.00.00 TOTAL FEES PAID BY RECEIPT: R8049 0.00 $149.00 $2,037.85 Date Paid: Tuesday, March 29, 2016 Paid By: ELDER -JONES Pay Method: CHECK 74015 Printed: Tuesday, March 29, 2016 2:36 PM 1 of 1 :, WlYSTEMS INSPECTION RECORD Retain a copy with permit 1M1�-04y� INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Pro'ect: I�F/ rae- l Type of Inspection: EC 1-I 1'fa L Address: 1 -72s0 ui-HcrA1Ze Pxw Date Called: Special Instructions: 1z� Date Wanted: a. 1� /G Requester: Phone No: INApproved per applicable codes. 1l Corrections required prior to approval. -1/1f/l4 7/// REINSPECTION FEE REQUIRED. Prior to next inspecfion, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. 0/INSPECTION RECORD c Retain a copy with permit * i6 )0�(4 INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-93507),��--�� Project: Xr I V ro Oil Type f Inspection: k__ _4 Address: ZSo o v� Cif Prkwv Date Calle . A 1716 Special Instructions:to lf4 /f Wanted• a.m. f�6 p.m. Requester: Phone No: Approved per applicable codes. Corrections required prior to approval. COMMENTS: Inspector �� Date: , 611� REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. � I V 00'i0 TEs a rt o Cx AANC RV1GE5 • PEARLE VISION SOUTHCENTER • • IUKWILA, WA • JORGE ACOSTA SYSTEM: AREA SERVED: TEST DATA DATA SHEAVE & BELT DATA MOTOR MFG. SPECIFIED ACTUAL FAN SHEAVE / BORE AK56 X 1" TOTAL CFM- FAN 2020 1937 BELT SIZE A35 TOTAL CFM - OUTLET 2020 1937 QUANTITY 1 R/A CFM 1520 1429 SHAFT C / C 13" O/A CFM 500 508 MOTOR SHEAVE / BORE 1VL40 X 7/8" FAN RPM MOTOR RPM 1100 SHEAVE ADJUSTMENT MAX CITY OF TUKwILA JUL 112016 PERMIT CENTER MOTOR DATA DESIGN E.S.P. MOTOR MFG. AO SMITH 0.50 " W.C. SPECIFIED ACTUAL MOTOR HP 1.5 VOLTAGE 208 211 1 210P13.8 10 SERVICE FACTOR 1.15 AMPERAGE 5.0 3.8 3.8 PHASE / Hz 3/60 HEATER SIZE / RATING THERMALLY PROTECTED MOTOR RPM 1725 1725 MOTOR FRAME# 56H CITY OF TUKwILA JUL 112016 PERMIT CENTER TEST PRESSURES DESIGN E.S.P. " W.C. INLET S.P. 0.50 " W.C. ACTUAL E.S.P. 0.75 " W.C. OUTLET S.P. 0.25 " W.C. CITY OF TUKwILA JUL 112016 PERMIT CENTER �' o AABC SCRVICSS E41 PEARLE VISION SOUTHCENTER TUKWILA, WA JORGE ACOSTA SYSTEM: AREA SERVED: AREA SERVED NO. CODE SIZE AK DESIGN FPM CFM INITIAL FPM CFM G/o OF DESIGN FPM FINAL CFM O/o OF DESIGN RETAIL 1 S1 8" F.H 180 142 79% 188 104% RETAIL 2 S1 8" F.H 180 117 65% 164 91% RETAIL 3 S1 8" F.H 180 146 81% 185 103% RETAIL 4 Sl 8" F.H 180 123 68% 173 96% RETAIL 5 S1 8" F.H 180 124 69% 168 93% RETAIL 6 S1 8" F.H 180 129 72% 168 93% RETAIL 7 S1 8" F.H 180 116 64% 176 98% RETAIL 8 S1 8" F.H 180 110 61% 168 93% RETAIL 9 S1 8" F.H 180 146 81% 172 96% RETAIL 10 S2 8" F.H 200 160 80% 180 90% RETAIL 11 S2 8" F.H 200 165 83% 195 98% SUPPLY 2020 1478 73% 1937 96% RETAIL Rl DUCT 19"X19" 2.51 606 1520 400 1003 66% 570 1429 94% RETURN 1520 1002.8 66% 1429 94% OSA 500 475 950/0 508 102% FORM ID: LOW VELOCITY TEST SHEET �sYrlr� A�� cx SIrRYIR;€S • PEARLE VISION SOUTHCENTER • • TUKWILA, WA • JORGE ACOSTA SYSTEM: AREA SERVED: • • • AABC TEST DATA DATA SHEAVE & BELT DATA MOTOR MFG. SPECIFIED ACTUAL FAN SHEAVE / BORE AK56 X 1" TOTAL CFM- FAN 2235 2106 BELT SIZE A35 TOTAL CFM - OUTLET 2235 2106 QUANTITY 1 R/A CFM 1985. 1855 SHAFT C / C 13" O/A CFM 250 251 MOTOR SHEAVE / BORE 1VL40 X 7/8" FAN RPM 1725 1100 SHEAVE ADJUSTMENT MAX VFD DRIVEN FAN SHEET MOTOR DATA DESIGN E.S.P. MOTOR MFG. AO SMITH 0.45 " W.C. SPECIFIED ACTUAL MOTOR HP 1.5 VOLTAGE 208 211 210 -210 SERVICE FACTOR 1.15 AMPERAGE 5.0 3.8 3.9 3.8 PHASE / Hz 3/60 HEATER SIZE / RATING THERMALLY PROTECTED MOTOR RPM 1725 1725 MOTOR FRAME# 56H VFD DRIVEN FAN SHEET TEST PRESSURES DESIGN E.S.P. " W.C. INLET S.P. 0.45 " W.C. ACTUAL E.S.P. 0.75 " W.C. OUTLET S.P. 0.30 " W.C. VFD DRIVEN FAN SHEET TE n c. AABC • PEARLE VISION SOUTHCENTER • • TUKWILA, WA • JORGE ACOSTA SYSTEM: AREA SERVED: • • • SERVED NO. CODE SIZE AK FPM DESIGNAREA CFM FPM CFM DESIGN FPM CFM DESIGN HALLWAY 1 Sl 8" F.H 120 75 63% 109 91% PUBLIC RESTROOM 2 Sl 6" F.H 50 29 58% 45 90% EMPLOYEE AREA 3 S1 8" F.H 165 62 38% 150 91% EMPLOYEE AREA 4 S1 8" F.H 165 78 47% 152 92% EMPLOYEE RESTROOM 5 Sl 6" F.H 50 26 52% 48 96% OFFICE 6 S1 8" F.H 230 84 37% 225 98% EMPLOYEE AREA 7 S1 8" F.H 165 96 58% 160 97% LENS PROCESS 8 S1 8" F.H 280 95 34% 265 95% LENS PROCESS 9 S1 8" F.H 280 110 39% 258 92% OFFICE 10 S1 8" F.H 100 34 34% 92 92% CONTACT LENS 11 Sl 8" F.H 160 94 59% 155 97% REFRACTION ROOM 12 Sl 8" F.H 140 73 52% 132 94% REFRACTION ROOM 13 Sl 8" F.H 140 60 43% 130 93% PRE-TEST ROOM 14 Sl 8" F.H 130 65 50% 120 92% FILE STORAGE 15 Sl 6" F.H 60 46 77% 65 108% SUPPLY 2235 1027 46% 2106 94% HALLWAY R1 DUCT 19"X19" 2.51 792 1985 380 953 48% 735 1843 93% RETURN 1985 953 48% 1843 93% OSA 250 74 30% 263 105% FORM ID: LOW VELOCITY TEST SHEET AABC SERV•C.9 • PEARLE VISION SOUTHCENTER • • TUKWILA, WA • JORGE ACOSTA REMARKS: FORM: DIRECT DRIVE TEST DATA UNIT DATA UNIT ID EF -1 EQUIP. LOCATION CEILING AREA SERVED LENS PROCESS MANUFACTURER GREENHECK MODEL # SP-B150-QD SERIAL # 60282453 FAN DATA DESIGN CFM 100 ACTUAL CFM 105 TSP 0.4 FAN RPM MOTOR DATA MANUFACTURER GREENHECK HORSE POWER 0.2 VOLTS 115 AMPS 1.8 SERVICE FACTOR 1 MOTOR RPM 1050 SPEED SINGLE FRAME 48 PHASE / HZ 1/60 HEATER SIZE THERMALL RHEOSTAT SETTING AREA SERVED NO. NONE CODE SIZE AK ' OF OF FPM CFM FPM CFM DESIGN FPM CFM DESIGN LENS PROCESS E1 EG 12X12 F.H 100 - 105 105% 105 105% REMARKS: FORM: DIRECT DRIVE TEST DATA ?ERMIi COORD COPY PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: M16-0048 DATE: 04/01/16 PROJECT NAME: PEARLE VISION SITE ADDRESS: 17100 SOUTHCENTER PKWY X Original Plan Submittal Response to Correction Letter # Revision # before Permit Issued Deferred Submittal #_ after Permit Issued DEPARTMENTS: A5- 41A)c 40A AIIA Lj--[Cj- c � Building Division Fire Prevention 12 Planning Division ❑ Public Works ❑ Structural ❑ Permit Coordinator ❑ PRELIMINARY REVIEW: DATE: 04/05/16 Not Applicable ❑ Structural Review Required ❑ (no approval review required) REVIEWER'S INITIALS: APPROVALS OR CORRECTIONS: Approved u Corrections Required ❑ (corrections entered in Reviews) Notation: DATE: DUE DATE: 05/03/16 Approved with Conditions r Denied ❑ (ie: Zoning Issues) REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: 12/19/2013 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Web site: http://w",",.Tukwi..]aWA.rov REVISION SUBMITTAL Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fax, etc. Date: Plan Check/Permit Number:1) ) 10 —Qo A ❑ Response to Incomplete Letter # I ❑ Response to Correction Letter # ❑ Revision # after Permit is Issued ❑ Revision requested by a City Building Inspector or Plans Examiner ❑ Deferred Submittal # Project Name: L lnaLc Project Address: I Qffi r>.st�FG't tzy-c.�i4� Contact Person: t; �� _��,?5� Phone Number: Summary of Revision: RECEIVED - CITY OF TUKWIL 4 JUN 14 2016 Sheet Number(s): "Cloud" or highlight all areas of revision including date of revision Received at the City of Tukwila Permit Center by: �-- Entered in TRAKiT on W:\Permit CenterlTemplatesTorrnsTevision Submittal Form.doc Revised: August 2015 LAKEVIEW CONSTRUCTION INC Home Fspahol Contact Safety & Health Claims & Insurance Washington State Department of Labor & Industries LAKEVIEW CONSTRUCTION INC Owner or tradesperson Principals MOON, KENT ALAN, PRESIDENT SUNDAY, EUGENE R. PRESIDENT (End: 01/10/2011) Doing business as LAKEVIEW CONSTRUCTION INC 10505 CORPORATE DR, #200 PLEASANT PRAIRIE, WI 53158 414-657-4222 Page 1 of 2 Search L&I �+ A-7 Index Help boy L&I Workplace Rights Trades & Licensing WA UBI No. Business type 601 447 862 Corporation Governing persons ADAMSON E DEWAYNE EUGENE R SUNDAY; KENT A MOON; License Verify the contractor's active registration / license / certification (depending on trade) and any past violations. Construction Contractor ..................... _... _................... _....................... Active. Meets current requirements. License specialties GENERAL License no. LAKEVC1072KC Effective — expiration 05/03/1993— 01/1312017 Bond ............._. TRAVELERS CAS & STY CO OF AMER $12,000.00 Bond account no. 400MJ9662 Received by L&I Effective date 02/17/2006 04/23/2006 Expiration date Until Canceled Insurance ........................ _. National Fire Ins of Hartford $1,000,000.00 Policy no. 5082945285 Received by L&I Effective date 01/11/2016 01/01/2015 Expiration date 01/01/2017 Insurance history https:Hsecure.Ini.wa.gov/verify/Detail,aspx?UBI=601447862&LIC=LAKEVCI072KC&SAW= 5/23/2016 I 1 1 I i ---- - I 1 i -------------------------------------------------- - - - - - - - - - - - -- --------------------- -- - -- - -- - - - - -- - ----------------J 1 ----1-------------------- 4- -- -- -- - -------------------- -- - ----------------------- -- -- -- -- -- -- -- -- - -- -- - - s �------- - ---- III I ---------------- �---------------------- - --------------- i 1- - - - - - - - -1- - - - - - - - - - - - - - - - - - L 1 L 4 i __t III t t t t t t i I t t i ! °------- ' ----- ' ----- t ----- ' III ------- ------- -- -- -- q , r�--------Tom--------T�------ ^-------- � - - - - - III -----' (FSC) LIGHT/ (a) LIGHT/ I � --T. T�--------T�--------T�--------T�--------T^ -TI- Tr T� T� T� 1 t -----------LLL-----'----------------------------------------------- _ III EXHUPST-- -- - --------- - - -- - -- - -- ------------ 0 - - - -------------------------------------------------- -------------------- - - - - - - - -- - -- - -- -- --- O EXHUA5T �----------J-�--------J----------1- _--------�---------J-----_-_-----t- _ - - ---- r---, !��------ ----------------F-J --------- i, - - - `- - - - - - - - -- ------ - -- - -- III t 0 t '- f ,r iii I I ' �� ��� isP; III I i i I I I I � J I L J � I I _J i I --;- - - t j ! ! i ! ! - - - - /�------------ - - - - - - - - - - - - - - -- ------------ -J-i- - - --------------------------- --------------------- - -----J i t ' ' -- -- -- ------------ ---- -/- - ---------`-------•-------•---------`-------------------------`------------------------------------`----------------------`-----------�I i �- 2 r1 � L � I i ---- Si --- / ---- j r� iSP� LJ , I I i I i i i t i t t t t t t t i I I - - - - -- - -- - - �J--------- - - - ------------------ - - ------------ - - - - ------ ---- - - I I t t ----`-- r------ I I ------------------------- - -- -- - -- -- -- -- ------------ -- ------ ------------------- ---------------------------- -- ---- - - --------------------- �',N— FLEX -1 i __' FLEX` ________ ______ ______ _ t _ _ _ _ _____ ----------- _T I t t t I I '--------- `-------- T`--------T`--------T`------- ~----------------- .--------T`_-_-------T�--------Tt-'------ __T`- -- - -T` - --- — ,-----___--------'-------------------- ----------_-____--------- I iI i t i-------- ------ ------------r;-------------------T`------------------'---------------------t-----------------------:----------------- ------------------------------------------------ ----------------- -J_'--------_'.Lr---------------_Li---------�`---------.t.- ------ J`I �-�j I I t r r L---------�-------- �--------------------t---------�r��--------J--------�'------- ----- II- I -� r - I I / I L--- I I L ---J I I I ----J ------' 'L------ -� -------------_-_____--- �-Lr-------J __---------- ; ------ ______--------------- -------------------- ----------------- -- -•----------------------------------- - - - - - - t t t f - ------------ - - - - -- - -- - - - ---------------- ---------------------------- - - -- --------------------- -- - ----- - - -- - - -' J' -� -- -L---� - - -J ----------------------------------- - - - - - -- - -- -- -- ! — ` - ------------- --------I t t -- r -t y----- I i t t It;�� i , I i i2 i J I t ----- _T_______.__. - r r __ _____________________� µ--------------- µ- I I.t \FLEx I I I I I I I I I I I �' I 1 2 _J -------- - -- - - -- - - - - - - - - ------------ - - - --- -- - --- ...,� I L -- - -�, •�/�� -- - -------�-- - - _ i - -- - -- - -- - --- ---- - --��-- -- -- -- -- -�- -irk— �Z- ��-�- ----- ------ ----- ------- -------------------•---•----- ----------••--i `---•••••••••------- --- ' i 1 I .rl --- --------- t t _ ' I I r +-r- t -r--- T +-r-- j T-- yT-- 'f"T- : I I --'--------'---�---' 1--�-----------r�--------+�------------------+-i II I II I II III i , I t---------+�-------I--+1--------+1--------+�-----1 + + + T II____JII IL ----II-------- -----------------------------------IL- --J I I t ! LL --�- --- ---------------I----�---------- ------------ ------------------------ I I i t t tt - - - --------------------------------------------------------------------- --------------- - - - - 1 III ---------- -- ---- --- --- --- --- -- ------- -F r- ----- -- ----- - ----- - -— �_ i — ----- -I-�-i-la--�--- Ti- !�-!�---��+---- ---- — — — — d� -- -----------------------��- I SPt i GSP� 1 --- -------_-----, _ III t I I �_y _� ——--------------------- — —---------- 1 24 r T — — — — — — — — — — — — — — — — — — — — _ — _ _ _ _ _ J I— — _ ' ' i i __ ________ _ _—___ ________ ___—_—_________ ' ' 1 ' �!--- __-- _ _____---_---__-___ _-- - - _______:____-------------:_____________________ ��—= T TIT --------' ------------------- ; -------------- ; -------------� --t-------I � -----'------------------------------------------- I 1 � I FI -I iL J �--8 DU ORK DUCTWORK;— I I i 1 — I I - - - - - - - -- - - - - ------ - - ------------ :_1.3_.1 1 _'AEF_ -' --- -- - - - -- -` --- J FLEX --i- - - - - -- - - -- - -- -- --- - - --_ - j - - - --- ------------- - - - I3-0 iR�FF---- - -- - -- ` -- i 1 '� --------� �� i ? �� � � i �- � , � Ir- ------------- j ! I --------------------- III ! ! ! ! .� _ ! t -i I I I " } Ir j I I 1 I I I III! t I 7C i II +) I� II �I t t --------- -- -------------------- I ---J� --- --- --------' ---- r ------- T- I _T= ---- _-- T- - -- -- - -- - -- - - - - ---------------- - - - - --- - --------- ----- - - - - — - - __ -- -- ' I ----y ----------'- - _t'6— L -�--�- 1-�---------`-- � �--- T---------- ------ ---- -- - - - h t ;_ _- -- - --IIIt L---- J ---- -t--------------- -------- -------- -------- -------- :� t T y -� '==1-- L J I i P�i I .�f� T� iJ_ iJ y -r LIJ d i 2 ! i i j ! -------- -------- - ------- ---------T------ --------�j--T----�_� 6•-•1 ---------'-------------------------------------------•------ `-------------------- `----------•------ ------------------- - ------------------- —--•----------------------------------- -------------------------- ------------------------------- --- ------------------------------------••-- —••-- ----•_•--•_-----•- --- -------------- I --'------------___ ; —`— 1 r r Tr T r 7 1 1 _- � -- 1 1 1 i 1 1 1 1 1 I I 1 MECHANICAL DEMOLITION PLAN SCALE: 1/4" = P-0" 73 O 5 O t 6 O CV N% PLAN NORTH ® KEY N OTE5 MARK DESCRIPTION ROOFTOP UNIT TO REMAIN. ALL ACCESSORIES, CONTROLS, ETC. TO REMAIN UNLESS OEXISTING NOTED OTHERWISE. EX15-PING DUCTDROPS TO REMAIN. OALL EXISTING DUCTWORK AND AIR DEVICES TO BE REMOVED THROUGHOUT SALES AND STOCK AREA. OEXISTING RESTROOMS TO REMAIN, INCLUDING SUPPLY DIFFUSERS, EXHAUST FANS AND EXHAUST DUCTWORK. EXISTING SUPPLY DUCTWORKTO BE REMOVED. TRUE NORTH DEMOLITION NOTES: A. CONTRACTOR SHALL VISIT THE SITE PRIOR TO BID AND H. DEMOLISH EXISTING AS REQUIRED PER NEW CONSTRUCTION SHALL BE FAMILIAR WITH THE LIMITS OF DEMOLITION AS DIRECTED BY ARCHITECT AND/OR AS NOTED ON REQUIRED FOR ALL TRADES. COORDINATE DEMOLITION WITH DRAWINGS. AVOID DISRUPTION OF SERVICES DURING REQUIREMENTS OF NEW CONSTRUCTION PRIOR TO BUSINESS HOURS (IF APPLIC9 LE). ALL SYSTEM INITIATING WORK. SHUT -DOWNS AND D!SRUPTION OF SCHEDULED AFTER NORMAL BUILDING FOURS OR AS OTHERWISE APPROVED B. CONTRACTOR SHALL BE RE51"ON5115LE FOR PROVIDING BY OWNER. COMPLETE : V O El N V ry GENERAL N OTE5 KEY NOTES ALL WORK MUST COMPLY WITH THE REQUIREMENTS OF LOCAL CODES AND DESCRIPTION ORDINANCES. WHERE INSPECTIONS ARE REQUIRED BY AUTHORITIES HAVING A JURISDICTION, WORK MUST NOT BE CONCEALED UNTIL INSPECTIONS AND TESTING FIELD VERIFY EXACT SIZE AND LOCATION OF EXISTING DUCTWORK PRIOR TO ARE COMPLETED AND ACCEPTED. BEGINNING WORK. PRIOR TO BID, GENERAL CONTRACTOR MUST BECOME THOROUGHLY FAMILIAR WITH CONNECT NEW RETURN AIR DUCT TO EXISTING RETURN DUCT UP TO EXISTING RTU. THE REQUIREMENTS OF THE GENERAL NOTES AS WELL AS ALL OTHER NOTES SHOWN PROVIDE 18" X 18" OPENING IN TOP OF RETURN DUCT STUB FOR RETURN AIR ON THE CONTRACT DOCUMENTS. VISIT THE SITE TO ESTABLISH THE EXISTING B. CONDITIONS PRIOR TO BID AND PRIOR TO ANY DUCT, PIPE OR EQUIPMENT RETURN INTO PLENUM SPACE, AND UP A MINIMUM OF TWO FEET OF RTU VERTICAL FABRICATION. SYSTEMS MUST BE ERECTED USING GENERAL CONTRACTOR'S FIELD RETURN DUCT. MEASUREMENTS FOR COORDINATION WITH EQUIPMENT, STRUCTURE, FIRE RELOCATE EXISTING THERMOSTAT AND PROVIDE NEW THERMOSTAT WIRING FROM PROTECTION AND ELECTRICAL CONDITIONS IN THE SPACE. TO RTU CONTROLLER. CONCEAL ALL CONTROL WIRING WITHIN WALLS AND ALL CONTRACT DOCUMENTS ARE DIAGRAMMATIC AND INDICATE THE GENERAL ABOVE CEILING. VERIFY OPERATION OF EXISTING THERMOSTAT PRIOR TO TURNOVER ARRANGEMENTS OR GEOMETRICAL RELATIONSHIPS OF EQUIPMENT AND SERVICES. C. THEY ARE NOT INTENDED TO SPECIFY OR SHOW EVERY OFFSET, SEQUENCE, DEVICE, RETURN AIR DUCT MOUNTED SMOKE DETECTORTO REMAIN. VERIFY OPTION, FITTING, OR COMPONENT. PROPER WORKING CONDITION AND REPAIR/REPLACE AS REQUIRED. THE CONTRACT DOCUMENTS REFLECT A SYSTEM DESIGNED AROUND SPECIFIC PROVIDE NEW EXHAUST FAN IN LENS PROCESS ROOM. ROUTE DUCTWORK UP REFERENCE PRODUCTS, THE SELECTION OF WHICH HAS IMPACTED THE DESIGNS OF ROOF TO ROOF CAP. COORDINATE ALL ROOF PENETRATIONS AND REPAIR OTHER TRADES. IF ALTERNATE MANUFACTURERS ARE SUBMITTED OR BID, IT 15 THE OF ROOF WITH LANDLORD'S ROOFING CONTRACTOR. MAINTAIN MINIMUM 10'-0" RESPONSIBILITY OF THIS GENERAL CONTRACTOR TO COORDINATE ALL DIFFERENCES D AND IMPACTS WITH ALL TRADES PRIOR TO BID, INCLUDING COSTS A550CIAl CD WITH EXISTING ROOFTOP UNIT TO REMAIN. REPLACE BELTS AND RE -LUBRICATE ALL MOVING REQUIRED CHANGES TO OTHER TRADES. NO EYTRA5 WILL BE ALLOWED FOR CHANGES PARTS PER MANUFACTURER'S RECOMMENDATIONS. REUSE EXISTING CONTROLS. REQUIRED TO OTHER TRADES IF ALTERNATE EQUIPMENT IS BID OR INSTALLED AT THE INSPECT REFRIGERATION CIRCUIT, PRESSURIZE, AND RECHARGE. STRAIGHTEN GENERAL CONTRACTORS OPTION. SECTION FINS, REPLACE ALL FILTERS WITH MINIMUM MERV 8 FILTERS. EXISTING MECHANICAL INFORMATION IS BASED ON LIMITED EXISTING BUILDING START UNIT AND COORDINATE WITH EQUIPMENT MANUFACTURER FOR ANY DRAWINGS AND FIELD WORK. THE GENERAL CONTRACTOR SHALL FIELD VERIFY THE E. EXISTING CONDITIONS FOR ACCURACY. NO ADDITIONAL COMPENSATION SHALL BE FUNCTIONALITY. BALANCE TO AIRFLOW NOTED ON PLAN. PROVIDE SHEAVE CHANGE ALLOWED FOR REVISIONS TO THE DESIGN TO CORRECT FOR EXISTING CONDITIONS TO ACHIEVE AIR BALANCE VALUES. NOT AS INDICATED ON THE PLANS. MANUAL BALANCE DAMPER ON RETURN DUCT SECTION. BALANCE TO CFM GENERAL CONTRACTOR SHALL NOTIFY TENANT, ARCHITECT AND ENGINEER OF ANY F. SITUATIONS THAT MODIFY OR INCREASE THE SCOPE OF WORK FROM THAT IS EXHAUST FANS EXISTING TO REMAIN. CLEAN AND REFURBISH TO DESCRIBED IN THE DOCUMENTS. LIKE -NEW CONDITION. GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR ALL CUTTING/PATCHING RELATED G TO THEIR WORK. SPACE ABOVE CEILING IS INDICATED TO BE A RETURN AIR PLENUM. CONSTRUCTION RETURN MATERIALS ABOVE CEILING SHALL BE NONCOMBUSTIBLE, OR HAVE A MAXIMUM 25 H FLAME SPREAD AND 50 SMOKE DEVELOPMENT FINISH RATING. WIRING SHALL BE 24" X 12" LABELED PLENUM RATED TYPE PER NEPA 70. ELEC ESP COORDINATE LOCATION AND ELEVATION OF MECHANICAL WORK WITH ALL DUCTWORK, 1. LIGHT FIXTURES, AND OTHER CEILING BUILT-IN FIXTURES. CONTACT ENGINEER OR PD ARCHITECT IMMEDIATELY SHOULD ANY CONFLICT ARISE. ALL ROOF PENETRATIONS, PATCHING AND FLASHING SHALL BE PERFORMED BY A � LANDLORD APPROVED ROOFING GENERAL CONTRACTOR AT THIS GENERAL J CONTRACTOR'S EXPENSE. COORDINATE ROOF PENETRATIONS AND ROOFTOP NOTE5/ACCE55ORIE5 EQUIPMENT LOCATIONS WITH LANDLORD AND GENERAL CONTRACTOR. NOTHING IS PERMITTED TO BE ATTACHED TO, SUSPENDED FROM, OR PENETRATE THE ROOF DECK. GENERAL CONTRACTOR MAY ATTACH TO OR SUSPEND FROM THE TOP K CHORD OF THE JOIST OR THE STRUCTURAL STEEL WHICH EXISTS ABOVE THE TENANT PHASE SPACE. L. ALL ROOFTOP UNITS TO BE LOCATED ON FACTORY SUPPLIED ROOF CURBS. MAINTAIN A MINIMUM OF I O' CLEARANCE TO ANY OUTSIDE AIR INTAKES ON ROOF FOR M ALL EXHAUST FANS. ASH RAE GENERAL CONTRACTOR TO LABEL ALL ROOFTOP EQUIPMENT WITH TENANT NAME, N. SPACE NUMBER AND EQUIPMENT IDENTIFICATION (RTU -1 , ETC.), PER MALL KVA SPECIFICATIONS AND STANDARDS. 0. NO PVC PIPING ALLOWED IN PLENUM AREAS. LION CHANGES IN DUCT SIZES SHALL BE MADE BY UNIFORM TAPER SECTION WITH A P MAXIMUM INCLUDE ANGLE OF DIVERGENCE OF 15 DEGREE. DUCT SIZES INDICATED REPRESENT CLEAR INTERIOR SHEET METAL DIMENSIONS AND IF Q. INTERNAL INSULATION IS SPECIFIED.THE DIMENSIONS INCLUDE ALLOWANCE FOR REFRIGERATION * AC ENGINEERS INTERNAL INSULATION. ELECTRICAL WATER COOLER ALL SUPPLY AIR DUCTWORK NOT EXPOSED OR INTERNALLY LINED SHALL BE EXTERNALLY R INSULATED. REFER TO SPECIFICATIONS. PANEL BRANCH DUCTS SERVING DIFFUSERS SHALL BE SIZED TO MATCH DIFFUSER NECK SIZE S INDICATED. ALL ROUND DUCT ELBOWS SHALL BE LONG SWEEP, 1- 1/2 TIMES THE CENTERLINE T RADIUS. B ALL CONDENSATE PIPING SHALL BE COPPER, AND INSULATED BELOW ROOF LINE. U. GENERAL CONTRACTOR SHALL VERIFY, PRIOR TO BID, THE CORRECT METHOD AND KW KWH LOCATION OF CONDENSATE DISCHARGE FROM UNITS WITH THE LANDLORD. PSI PITCH POCKETS ARE NOT PERMITTED ON THE ROOF FOR CONDENSATE DRAINS, V. POWER OR CONTROL WIRING. ALL CONNECTIONS ARE TO BE MADE INSIDE THE 12"0 EQUIPMENT CURB OR THROUGH PRE -MANUFACTURED PIPING CURB. GENERAL CONTRACTOR MUST REPLACE ALL AIR FILTERS IN HVAC UNITS WITH NEW W CLEAN FILTERS BEFORE AIR BALANCING AND PRIOR TO FINAL TURNOVER TO TENANT. IT IS THE RESPONSIBILITY OF THE MECHANICAL CONTRACTOR TO VISIT THE JOB SITE EXHAUST PRIOR TO CONSTRUCTION TO FAMILIARIZE HIMSELF WITH MAJOR ITEMS SUCH AS STRUCTURAL ELEMENTS, PLUMBING LOCATIONS, ELECTRICAL RUNS AND POINTS OF X. CONNECTION TO EXISTING DUCT SYSTEMS. ADDITIONALLY, MECHANICAL CONTRACTOR SHALL VERIFY EXACT LOCATIONS AND DIMENSIONS OF SUCH ITEMS AS HVAC EQUIPMENT, DUCTWORK, ETC. PRIOR TO COMMENCING ANY WORK. IT IS THE GENERAL CONTRACTOR'S RESPONSIBILITY TO ENSURE THAT THE MECHANICAL BD EQUIPMENT COMPONENTS ARE INSTALLED AT LOCATIONS AND ELEVATIONS WHICH Y MAKE THEM READILY AND SAFELY ACCESSIBLE FOR ROUTINE MAINTENANCE WITHOUT L REQUIRING ANY EXTRAORDINARY MEASURES. PVC THE TENANT RESERVES THE RIGHT TO CHECK CONSTRUCTION COMPLIANCE WITH V PLANS AND SPECIFICATIONS. SHOULD THE TENANT FIND CORRECTIVE WORK NECESSARY, HE WILL NOTIFY GENERAL CONTRACTOR OF SUCH WORK IN WRITING AND EXPECT COMPLIANCE PERFORMED WITH DUE DILIGENCE. IF ANY CORRECTIVE WORK 15 BLDG DEEMED TO BE NECESSARY, THE COST OF REIN5PECTION5 WILL BE BORNE BY THE fVAV GENERAL CONTRACTOR. IF WORK IS REQUIRED BY TENANT IN ORDER TO IMPROVE, CHANGE OR CORRECT AIR CONDITIONING OPERATIONAL CONDITIONS DUE TO: PART Z. MALFUNCTION, WARRANTY OR OTHER INABILITY TO PROVIDE THE COMFORT VD CONDITIONS REQUIRED BY THE STORE, GENERAL CONTRACTOR SHALL BE DIRECTED 20"x 1211 BY TENANT TO ADDRESS THIS WORK IN A TIMELY MANNER. IF IT BECOMES EVIDENT THAT THE GENERAL CONTRACTOR CAN NOT ACCOMPLISH THE TASK, THEN AFTER 72 POINT OF CONNECTION - NEW TO EXISTING HOURS OF WRITTEN NOTICE, THE TENANT MAY AT HIS DISCRETION TAKE OVER SUCH BOTTOM OF DUCT WORK AND BACK CHARGE THE GENERAL CONTRACTOR FOR ANY CORRECTIVE WORK THAT WAS REQUIRED DUE TO LACK OF PERFORMANCE, WORKMANSHIP AND/OR LEAVING AIR TEMPERATURE ADHERENCE TO PLANS AND SPECIFICATIONS. MECHANICAL FLAN SCALE: 114" = I ' -O" ® KEY NOTES MARK DESCRIPTION TAG CONNECT NEW SUPPLY AIR DUCT TO EXISTING SUPPLY AIR DUCT UP TO EXISTING RTU. O FIELD VERIFY EXACT SIZE AND LOCATION OF EXISTING DUCTWORK PRIOR TO MODEL BEGINNING WORK. FINISH CONNECT NEW RETURN AIR DUCT TO EXISTING RETURN DUCT UP TO EXISTING RTU. PROVIDE 18" X 18" OPENING IN TOP OF RETURN DUCT STUB FOR RETURN AIR O OPENING FROM PLENUM. PROVIDE LINED RETURN DUCTWORK ENTIRE LENGTH OF I RETURN INTO PLENUM SPACE, AND UP A MINIMUM OF TWO FEET OF RTU VERTICAL RETURN DUCT. 51 RELOCATE EXISTING THERMOSTAT AND PROVIDE NEW THERMOSTAT WIRING FROM LAY -IN TO RTU CONTROLLER. CONCEAL ALL CONTROL WIRING WITHIN WALLS AND ODEVICE ABOVE CEILING. VERIFY OPERATION OF EXISTING THERMOSTAT PRIOR TO TURNOVER STD. WHITE TO THE TENANT. REPORT ANY DEFICIENCY IN OPERATION TO THE ENGINEER. OEXISTING RETURN AIR DUCT MOUNTED SMOKE DETECTORTO REMAIN. VERIFY EAT EC PROPER WORKING CONDITION AND REPAIR/REPLACE AS REQUIRED. ID IE PROVIDE NEW EXHAUST FAN IN LENS PROCESS ROOM. ROUTE DUCTWORK UP FINISH ROOF TO ROOF CAP. COORDINATE ALL ROOF PENETRATIONS AND REPAIR OTHROUGH OF ROOF WITH LANDLORD'S ROOFING CONTRACTOR. MAINTAIN MINIMUM 10'-0" '— ® FROM ALL OUTSIDE AIR INTAKES. EXISTING ROOFTOP UNIT TO REMAIN. REPLACE BELTS AND RE -LUBRICATE ALL MOVING STD. WHITE PARTS PER MANUFACTURER'S RECOMMENDATIONS. REUSE EXISTING CONTROLS. 52 INSPECT REFRIGERATION CIRCUIT, PRESSURIZE, AND RECHARGE. STRAIGHTEN OCONDENSING SECTION FINS, REPLACE ALL FILTERS WITH MINIMUM MERV 8 FILTERS. ML -40 START UNIT AND COORDINATE WITH EQUIPMENT MANUFACTURER FOR ANY FINISH REPLACEMENT PARTS REQUIRED IN ORDER TO RESTORE UNIT TO FULL RI FUNCTIONALITY. BALANCE TO AIRFLOW NOTED ON PLAN. PROVIDE SHEAVE CHANGE LAY -IN TO ACHIEVE AIR BALANCE VALUES. OPROVIDE MANUAL BALANCE DAMPER ON RETURN DUCT SECTION. BALANCE TO CFM STD. WHITE INDICATED IN SCHEDULE. ORESTROOM EXHAUST FANS EXISTING TO REMAIN. CLEAN AND REFURBISH TO I LIKE -NEW CONDITION. GRILLE, REGISTER AND DI EFUSER Sheet SCHEDULE TAG SERVICE MOUNTING MFR MODEL MODULE SIZE FINISH NOTES A E I I O 51 SUPPLY LAY -IN TITUS TMS 24" X 24" STD. WHITE I ABV A/C AIR EAT EC ENTERING AIR TEMPERATURE ELECTRICAL CONTRACTOR (DIV 15) ID IE INSIDE DIAMETER INVERT ELEVATION FINISH OUTSIDE AIR (VENTILATION AIR) OPPOSED BLADE DAMPER THRU TSTAT SUPPLY '— ® SUPPLY AIR DIFFUSER - ARROWS INDICATE PATTERN. NO PATTERN (2) SLOT, 48" STD. WHITE 52 AIR LAY -IN TITUS ML -40 LONG FINISH TYP RI RETURN LAY -IN TITUS 50F 24" X 24" STD. WHITE ABOVE FINISHED FLOOR ELEV AIR I I I I FINISH R2 RETURN I LAY -IN TITUS 50F 24" X 12" STD. WHITE ELEC ESP ELECTRICAL EXTERNAL STATIC PRESSURE AIR PD PRESSURE DROP FINISH � RETURN AIR GRILLE NOTE5/ACCE55ORIE5 1. 5ECTORIZING BAFFLES FOR DIRECTIONAL CONTROL WHERE NOTED ON DRAWINGS PLAN NORTH (E) T -STAT PROGfZAMMING THERMOSTAT OCCUPIED COOL 730 UNOCCUPIED COOL 80° OCCUPIED HEAT G80 UNOCCUPIED HEAT GOO MONDAY - SATURDAY "ON" AT 8:00 AM "OFF" AT 9:15 PM SUNDAY "ON" AT 1 1:00 AM "OFF" AT G: 15 PM VERIFY OPERATING HOURS WITH LUXOTTICA PM. ADJUST PROGRAM ACCORDINGLY. NOTE: REPAIR OR REPLACE EXISTING THERMOSTAT AS REQUIRED. TRUE NORTH REV EWED FOR �3 tE COMPLIANCE. r . ED APPROV APR 2 5 2016 i� CRY bf T. 1 Y BtIILt' ING DIVISION DESIGN OF THE NON -DUCTED RETURN AIR PLENUM CEILING IS BASED ON THE REQUIREMENT THAT ALL MATERIALS IN THE RETURN AIR PLENUM CEILING ARE ALL LABELED AS PLENUM RATED AND MEET THE FLAME SMOKE SPREAD REQUIREMENTS FOR PLENUM INSTALLATION AND THE APPROVAL OF A RETURN AIR PLENUM FROM THE LANDLORD. FIRE WRAP PVC PIPING AS REQUIRED. IF THE ABOVE CONDITIONS CANNOT BE MET, THIS CONTRACTOR SHALL STATE THE AMOUNT TO BE ADDED TO HIS BASE BID FOR A TOTALLY DUCTED RETURN AIR SYSTEM. A Subsidiary of the Luxottica Group 4000 Luxottica Place Mason, Ohio 45040 Store # C6427 50UTf10ENTER SQUARE 17 100 Southcenter Parkway Tukwila, WA 98 188 -SPACE # 128 Active Revision Number ReV1510n5= Mark Date By Description 0 Arch itect/ Engineer FRCH DESIGN WORLDWIDE 311 Elm Street Suite 600 Cincinnati OH 45202 513 241 3000 www.frch.com rKGh / Architecture, Inc., F.C. Seal Te3"Ll Thorson -Baker + Associates C O N S U L T I N G E N G I N E E R S 3030 West Streetsboro Road (330) 659-6688 Ph. Richfield, Ohio 44286 (330) 659-6675 Fax ARCHITECTURAL SYMBOLS: ODOOR NUMBER Q REVISIONS ROOM NAME ROOM NUMBER X ELEVATION NO. e DETAIL NO. A-X.X SHEET NO. A-X.X SHEET NO. X SECTION NO. X -X. X ELEVATION NO. SHEET NO. A-X.X SHEET NO. PROJECT TYPE: CORPORATE ❑ FRANCHISE LAB TYPE: ❑ NEW IM RELOCATION ❑ REMODEL (OPEN) ❑ REMODEL (CLOSED) ❑ FULL LAB ❑ NO LAB FINISH LAB 51TE TYPE: ❑ INDOOR LOCATION OUTDOOR LOCATION Pearle 5tandard Version Number: VILA 'Cc 00 016 ITER I Pearle Vision Project No. CG427 Architect's Project No. 032580.000 Title MECHANICAL PLAN Date 03.18 -IG Sheet Drawn By : TBA ABBREVIATIONS Store Number M I O CG4271 HVAC SYMBOLS A E I O T ABV A/C ABOVE AIR CONDITIONER, AIR CONDITIONING, EAT EC ENTERING AIR TEMPERATURE ELECTRICAL CONTRACTOR (DIV 15) ID IE INSIDE DIAMETER INVERT ELEVATION OA OBD OUTSIDE AIR (VENTILATION AIR) OPPOSED BLADE DAMPER THRU TSTAT THROUGH THERMOSTAT '— ® SUPPLY AIR DIFFUSER - ARROWS INDICATE PATTERN. NO PATTERN HIGH EFFECENY TAP WITH DAMPER AND FLEX DUCT (AT DIFFUSER CONNECTION). ABOVE CEILING EDB ENTERING DRY BULB IN INCH, INCHESp TYP TYPICAL SHOWN EQUALS 4 -WAY. AFF ABOVE FINISHED FLOOR ELEV ELEVATION IN WC INCHES OF WATER COLUMN I ' I V ROUND DUCT BRANCH TAKE -OFF FROM ARCH ARI ARCHITECT, ARCHITECTURAL AIR CONDITIONING $ REP RIG INSTITUTE ELEC ESP ELECTRICAL EXTERNAL STATIC PRESSURE PD PRESSURE DROP � RETURN AIR GRILLE RECTANGULAR MAIN WITH CONICAL TAP. PH PHASE UL UNDERWRITERS LABORATORIES, INC. ASH RAE AMERICAN 50CIETY OF HEATING, EWB ENTERING WET BULB KVA KILOVOLT -AMPS PLBG PLUMBING LION UNLESS OTHERWISE NOTED DUCTWORK SIZE TRANSITION. REFRIGERATION * AC ENGINEERS EWC ELECTRICAL WATER COOLER PNL PANEL B EWT ENTERING WATER TEMPERATURE KW KWH KILOWATTS KILOWATT-HOUR PSI POUNDS PER SQUARE INCH V 12"0 ROUND DUCTWORK. DIAMETER IN INCHES. EXH EXHAUST PRV PRESSURE RELIEF VALVE TURNING VANES BD BACKDRAFT DAMPER EX, (E) EXISTING L PVC POLYVINYL CHLORIDE V VOLT, VENT RECTANGULAR DUCTWORK. SIZE IN INCHES, BLDG BUILDING fVAV VD VARIABLE AIR VOLUME VOLUME DAMPER 20"x 1211 FIRST NUMBER IS SIDE SHOWN. POINT OF CONNECTION - NEW TO EXISTING BOD BOTTOM OF DUCT LAT LEAVING AIR TEMPERATURE BOP BOTTOM OF PIPE FA FIRE ALARM L55,# POUNDS VTR VENT THROUGH ROOF E305 BOTTOM OF STRUCTURE FACP FIRE ALARM CONTROL PANEL CLEANOUT LDB LEAVING DRY BULB LINEAR FEET RA RCP RETURN AIR REFLECTED CEILING PLAN, W SUPPLY OR OUTSIDE AIR DUCT MANUAL VOLUME DAMPER BTU BRITISH THERMAL UNIT FCO FLOOR LF C FIA FLEX FULL LOAD AM P5 FLEXIBLE LRA LOCKED ROTOR AMPS RD REQD ROOF DRAIN REQUIRED W WATT, WIDTH RETURN OR RELIEF AIR DUCT (D THERMOSTAT RECEIV FP FIRE PROTECTION LWB LWT LEAVING WET BULB LEAVING WATER TEM PERATURE REV REVISION, REVISE W/ WITH CITY OF TU CFH CFM CUBIC FEET PER HOUR CUBIC FEET PER MINUTE© FPM FEET PER MINUTE RG RETURN GRILLE WB WET BULB CARBON DIOXIDE SENSOR FT FOOT, FEET M RLA RUNNING LOAD AMPS DIFFUSER/GRILLE LABEL: VAAR Z J CLG CO CEILING CLEANOUT Of DEGREES FAHRENHEIT RPM REVOLUTIONS PER MINUTE RELOCATE A B A - TYPE/DESIGNA ION D ® DUCT SMOKE DETECTOR CONN CONNECT, CONNECTION G MAX MBTU,MBH MAXIMUM 1000 BTU PER HOUR (R) C B - NECK SIZE (INCHES) ;ERM{T CE CW COLD WATER MC MECHANICAL CONTRACTOR (DIV 15) 5 C -AIRFLOW (CFM) D G GAS MCA MINIMUM CIRCUIT AMPACITY Ot --► SHEET KEYNOTE REFERENCE GAL GALLON MCB MAIN CIRCUIT BREAKER 5A SUPPLY AIR 90 DEGREE DUCTWORK ELBOW DB DRY BULB GC GENERAL CONTRACTOR MD MOTORIZED DAMPER SAN SANITARY W/ TURNING VANES. ROUND DEG DEGREES GPM GALLONS PER MINUTE MECH MECHANICAL SD SMOKE DETECTOR DIA (OR 0) DIAMETER N 'I MFR MIN MANUFACTURER MINIMUM SF 5MACNA SQUARE FEET, SQUARE FOOT SHEET METAL * A/C CONT NAT'L ASSOC. - RADIUS DUCTWORK ELBOW— UC UNDERCUT DOOR I" FOR AIRFLOW DIM (D) DIMENSION DEMOLISH H HEIGHT MOCP MAXIMUM OVER CURRENT pROTfCTIOi, SP STATIC PRESSURE ROUND OR RECTANGULAR. —� DN DOWN HORIZ HORIZONTAL MTD MOUNTED SPEC SPECIFICATION DWG DRAWING HP HORSEPOWER, HEAT PUMPSTD N STANDARD (E) EXISTING DX DIRECT EXPANSION HTG HEATING RECTANGULAR INCH TAKE -OFF (R) RELOCATE HTR HEATER N/A NOT APPLICABLE N WITH 45 DEGREE BRANCH INLET. HVAC HEATING, VENTILATING * A/C NEC NATIONAL ELECTRICAL CODE (D) DEMOLISH HW HOT WATER NEMA NATIONAL ELECTRICAL MFR'S ASSOC. NEPA NATIONAL FIRE PROTECTION ASSOC. a NTS NOT TO SCALE lqb 00if A Subsidiary of the Luxottica Group 4000 Luxottica Place Mason, Ohio 45040 Store # C6427 50UTf10ENTER SQUARE 17 100 Southcenter Parkway Tukwila, WA 98 188 -SPACE # 128 Active Revision Number ReV1510n5= Mark Date By Description 0 Arch itect/ Engineer FRCH DESIGN WORLDWIDE 311 Elm Street Suite 600 Cincinnati OH 45202 513 241 3000 www.frch.com rKGh / Architecture, Inc., F.C. Seal Te3"Ll Thorson -Baker + Associates C O N S U L T I N G E N G I N E E R S 3030 West Streetsboro Road (330) 659-6688 Ph. Richfield, Ohio 44286 (330) 659-6675 Fax ARCHITECTURAL SYMBOLS: ODOOR NUMBER Q REVISIONS ROOM NAME ROOM NUMBER X ELEVATION NO. e DETAIL NO. A-X.X SHEET NO. A-X.X SHEET NO. X SECTION NO. X -X. X ELEVATION NO. SHEET NO. A-X.X SHEET NO. PROJECT TYPE: CORPORATE ❑ FRANCHISE LAB TYPE: ❑ NEW IM RELOCATION ❑ REMODEL (OPEN) ❑ REMODEL (CLOSED) ❑ FULL LAB ❑ NO LAB FINISH LAB 51TE TYPE: ❑ INDOOR LOCATION OUTDOOR LOCATION Pearle 5tandard Version Number: VILA 'Cc 00 016 ITER I Pearle Vision Project No. CG427 Architect's Project No. 032580.000 Title MECHANICAL PLAN Date 03.18 -IG Sheet Drawn By : TBA Checked By : TBA Store Number M I O CG4271 • Of 151 N r (V 67-4 REMOTE DAMPER ADJUSTMENT WHEN REQUIRED GALVANIZED SHEET YOUNG REGULATOR#502OCC OR #830 -CC SECURELY TAPE VINYL DUCT TO SHEET METAL METAL DUCT WITH #270-30 I OPERATOR WITH A MINIMUM OF TWO (2) CONTINUOUS GALVANIZED ELBOW MODEL No. WRAPS OF DUCT TAPE. STRAP CLAMP OVER MIN OA (CFM) MANUAL DAMPER FLEX DUCT INSULATION *VINYL TO SHEET COOLING DATA WHEN ACCESSIBLE WHEN ACCE5511BI-Fl- METAL. TAPE INSULATION TO DUCT TO FORM METAL STRAP CLAMP PLENUM COLLAR A GOOD SEAL. (TYPICAL) 2 PLACES INSULATED PLENUM INPUT (MBH) OUTPUT (MBH) VOLTAGE (V -(P -Hz) AIR INSULATED FLEXIBLE (E)RTU- I RETAIL CONNECTION. (MAX. 5'-0") DJOGON05 FLOW IN VERTICAL ONLY NOTE: INSULATED ROUND SUPPLY i THERMAL INSULATING DUCT TO SUPPLY AIR MAIN 1 BLANKET REQUIRED FOR 80 SULATION WITH FOIL FACING FIRE RATED CEILINGS ONLY CABLE 3'-0" INSULATED FLEXIBLE CONNECTION SUPPLY AIR DIFFUSER � (E)KTU-2 OPERATOR WITH COVER PLATE YORK y yy METAL BAND LINEAR SLOT DIFFUSER ! LINEAR DIFFUSER MOUNTING DETAIL FLEXIBLE DUCT MOUNTING DETAIL 1 100 (DI SCALE: NONE 29 SCALE: NONE - SLOPE TOP OF DUCT I NOTES: FOR WATER DRAINAGE 1 1 54 5 NOTES/ACCESSORIES RECTANGU R ROUND I . HVAC CONTRACTOR TO COORDINATE 224 —� DUCTWORK —� DUCTWOR INSULATION W/ROOFING CONTRACTOR HOUSE FOR PROPER SEQUENCE TO PERMIT VARIES FLASHING AND COUNTER FLASHING DUCT INSTALLATION. LINING RESTROOM 2" MINIMUM Jv NA COLLAR NA POP RIVET AND SEAL SEAM FULL PERIMETER RECTANGULAR TO ROUND 450 LATERAL FITTING NA 18 GAUGE GALV. METAL COUNTER FLASHING "BUCKLEY FITTING" ROUNDRECTANGU R o ROOF INSULATION --� DUCTWORK D UCTWO N FABRICATED ROOF CURB 4" BRANCH DUCT HEIGHT DIMENSION 2" LESS THAN MAIN DUCT HEIGHT DIMENSION 90° COMBINATION TEE WITH OVAL RECTANGULAR TO RECTANGULAR TO ROUND TAP (IF BRANCH FLOW IS 2/3 OF THRU FLOW) EXISTING ROOF DECK SEE SPECIFICATION FOR DUCT INSULATION BELOW ROOF EXHAUST DUCT THROUGH ROOF DETAIL DUCT BRANCH TAKE -OSE DETAI L 4 2 SCALE: NONE SCALE: NONE OUTSIDE AIR SCHEDULE EXISTING ROOFTOP HEAT PUMP HVAC UNIT SCHEDULE TAG SERVICE MFR MODEL No. NOMINAL TONS MIN OA (CFM) SUPPLY FAN DATA VOLTAGE (V -(P -Hz) COOLING DATA GAS HEATING DATA UNIT CHARACTERISTICS NOTES/ ACCESSORIES SUPPLY AIR (CFM) TOTAL (MBH) SENSIBLE (MBH) COOLING STAGES INPUT (MBH) OUTPUT (MBH) VOLTAGE (V -(P -Hz) UNIT MCA UNIT MOCP (E)RTU- I RETAIL YORK DJOGON05 5 OCCUPANCY 500 2020 CFM PER G4 45 1 100 80 205 -230 -3 -GO 29 30 - (E)KTU-2 OD / BOH YORK DJOGON08 5 250 2235 G4 45 1 100 80 208 -230 -3 -GO 29 30 - 42G (E) RTU -1 500 EMPLOYEE/BACK OF 1 1 54 5 NOTES/ACCESSORIES 5 O.OG 224 (E) RTU -2 250 OUTSIDE AIR SCHEDULE EAN SCHEDULE TAG SPACE OUTSIDE AIR REQUIREMENTS MFR MODEL No. AIRFLOW (CFM) ESP (IN WC) MOTOR (W) (ASHRAE G2.1-20 10) VOLTAGE (V -(P -Hz) NOTES SPACE DESIGNATION FLOOR AREA COOK I SERVICE REQUIRED OUTSIDE AIR (CFM) 98 DIRECT 120- 1 -GO SEE BELOW 1. ACCEPTABLE MANUFACTURERS: BRASCH, CHROMALOX, INDEECO, MARKEL, TRANS. 2. PROVIDE WITH RECESS MOUNTING ENCLOSURE, INTEGRAL DISCONNECT SWITCH, AND INTEGRAL THERMOSTAT. (SF) NOTES/ACCESSORIES I . AM CA SEAL � U. L. LISTED OCCUPANCY NUMBER CFM PER CFM PER MINIMUM #/ 10005Q.FT Of PERSON SQ.FT. CFM PEOPLE SALES FLOOR 14GG 15 22 7.5 0.12 42G (E) RTU -1 500 EMPLOYEE/BACK OF 1 1 54 5 22 5 O.OG 224 (E) RTU -2 250 HOUSE RESTROOM 114 NA NA NA NA NA NA MINIMUM OUTSIDE AIR REQUIRED = G50 CFM MINIMUM OUTSIDE AIR DELIVERED = 750 CFM EXHAUST EAN SCHEDULE TAG SERVICE MFR MODEL No. AIRFLOW (CFM) ESP (IN WC) MOTOR (W) DRIVE VOLTAGE (V -(P -Hz) NOTES EF- I LENS PROCESS COOK GC -144 100 0.4 98 DIRECT 120- 1 -GO SEE BELOW 1. ACCEPTABLE MANUFACTURERS: BRASCH, CHROMALOX, INDEECO, MARKEL, TRANS. 2. PROVIDE WITH RECESS MOUNTING ENCLOSURE, INTEGRAL DISCONNECT SWITCH, AND INTEGRAL THERMOSTAT. 3. FIELD CONVERT TO WATTAGE AND PHASE SPECIFIED.,- �» NOTES/ACCESSORIES I . AM CA SEAL � U. L. LISTED 2. ROUND OUTLET COLLAR WITH INTEGRAL BACKDRAFT DAMPER 3. CONTROL WITH ROOM LIGHT SWITCH ELECTRIC UNIT HEATER SCHEDULE TAG MFR MODEL No. TYPE FAN CFM MBH HEATING CAPACITY (KW) VOLTAGE (V �) AMPS NOTES EUH- I Q -MARK CDF548 CEILING 300 10.2 3.0 208-3 14.4 SEE BELOW NOTES/ACCESSORIES 1. ACCEPTABLE MANUFACTURERS: BRASCH, CHROMALOX, INDEECO, MARKEL, TRANS. 2. PROVIDE WITH RECESS MOUNTING ENCLOSURE, INTEGRAL DISCONNECT SWITCH, AND INTEGRAL THERMOSTAT. 3. FIELD CONVERT TO WATTAGE AND PHASE SPECIFIED.,- �» A Subsidiary of the Luxottica Group 4000 Luxottica Place Mason, Ohio 45040 Store # C6427 SOUTIICENTER SQUARE 7 100 Southcenter Parkway Tukwila, WA 98 188 SPACE # 128 Active ReV151on Number Revl5ion5: Mark Date By Description 0 311 Elm Street Suite 600 Cincinnati OH 45202 513 2413000 www.frch.com FRCH / Architecture, Inc., P.G. Seal eYP 'V/b// 7 103 Thorson -Baker + Associates C O N S U L T I N G E N G I N E E R S 3030 West Streetsboro Road (330) 659-6688 Ph. Richfield, Ohio 44286 (330) 659-6675 Fax ARCHITECTURAL SYMBOLS: REVISIONS O DOOR NUMBER ROOM NAME ROOM NUMBER X ELEVATION NO. e DETAIL NO. A-X.X SHEET NO. A-X.X SHEET NO. X SECTION NO. X -X. X ELEVATION NO. A-X.X SHEET NO. SHEET NO. PROJECT TYPE: ❑ NEW CORPORATE RELOCATION ❑ FRANCHISE ❑ REMODEL (OPEN) ❑ REMODEL (CLOSED) LAB TYPE: ❑ FULL LAB ❑ NO LAB FINISH LAB 51TE TYPE: ❑ INDOOR LOCATION OUTDOOR LOCATION Pearle 5tandard Version Number: