Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Permit M16-0053 - BOEING EMPLOYEES CREDIT UNION (BECU) / BUILDING 9 - DUCTLESS SPLIT SYSTEM
BECU 13035 GATEWAY DR M16-0053 City of Tukwila • Department of Community Development • 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 20.6-431-3670 Inspection Request Line: 206-438-9350 Web site: http://www.TukwilaWA.gov MECHANICAL PERMIT Parcel No: 0004800015 Permit Number: M16-0053 Address: 13035 GATEWAY DR BLDG 9 Issue Date: 5/9/2016 Permit Expires On: 11/5/2016 Project Name: BECU Owner: Name: EPROPERTY TAX INC DEPT#207 2012 Address: PO BOX 4900, SCOTTSDALE, WA, 2014 85261 2012 Contact Person: 2014 Name: DARLA DOLL Phone: (206) 768-4278 Address: 7717 DETROIT AVE SW, SEATTLE, WA, 2014 98106 2012 Contractor: 2012 Name: MACDONALD/MILLER FAC SOL INC Phone: (206) 768-4180 Address: PO BOX 47983, SEATTLE, WA, 98146- 7983 License No: MACDOFS980RU Expiration Date: 1/3/2017 Lender: Name: Address: DESCRIPTION OF WORK: INSTALL (1) DUCTLESS SPLIT SYSTEM - ROUTE REFER PIPING TO NEW CONDENSING UNIT ON ROOF. INSTALL APPROX (50) GRD'S AND MISC DUCT WORK Valuation of Work: $19,800.00 Fees Collected: $454.94 Type of Work: NEW Electrical Service Provided by: SEATTLE CITY LIGHT Fuel type: ELECT Water District: TUKWILA Sewer District: TUKWILA SEWER SERVICE Current Codes adopted by the City of Tukwila: International Building Code Edition: 2012 National Electrical Code: 2014 International Residential Code Edition: 2012 WA Cities Electrical Code: 2014 International Mechanical Code Edition: 2012 WAC 296-46B: 2014 Uniform Plumbing Code Edition: 2012 WA State Energy Code: 2012 International Fuel Gas Code: 2012 Permit Center Authorized Signature: Date:—" I hearby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this development p it and a7 the conditions attached to this permit. Signature Date: �lv Print Nam This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: Work shall be installed in accordance with the approved construction documents, and any changes made during construction that are not in accordance with the approved construction documents shall be resubmitted for approval. 2: All permits, inspection record card and approved construction documents shall be kept at the site of work and shall be open to inspection by the Building Inspector until final inspection approval is granted. 3: All construction shall be done in conformance with the Washington State Building Code and the Washington State Energy Code. 4: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of this requirement. 5: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206-431-3670). 6: All electrical Work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center. 7: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 8: ***MECHANICAL PERMIT CONDITIONS*** 9: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431-3670). 10: Manufacturers installation instructions shall be available on the job site at the time of inspection. PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 0703 MECH EQUIP EFF 1800 MECHANICAL FINAL 0609 PIPE/DUCT INSULATION 0705 REFRIGERATION EQUIP 0701 ROUGH -IN MECHANICAL b CITY OF TUA. _ A Community Development Department PernJil Center • 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 littii://www.TtikwilaWA.L),ov Mechanical Permit No. Iy i I � - OM Project No. Date Application Accepted: Date Application Expires: I MECHANICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **please print** SITE LOCATION King Co Assessor's Tax No.: 0004800015 Site Address: 13035 Gateway Dr Tukwila, WA 98168 Tenant Name: GATEWAY / BLDG 9 / BECU PROPERTY OWNER Name: $ECU Address: 13035 GATEWAY DR City: TUKWILA State: WA Zip: 98168 CONTACT PERSON — person receiving all project communication Name: Darla Doll Address: 7717 Detroit Ave SW City: Seattle State: WA Zip: 98106 Phone: (206) 768-4278 Fax: (206) 768-4279 Email: darla.doll@macmiller.com Suite Number: #211 Floor: New Tenant: ❑ .....Yes 2 MECHANICAL CONTRACTOR INFORMATION Company Name: MacDonald Miller Address: 7717 Detroit Ave SW City: Seattle State: WA Zip: 98106 Phone: (206) 768-4278 Fax: (206) 768-4279 Contr Reg No.: MACDOFS980RU Exp Date: 01/03/2017 Tukwila Business License No.: BUS -0994318 Valuation of project (contractor's bid price): $ 19,800 Describe the scope of work in detail: INSTALL (1) DUCTLESS SPLIT SYSTEM - ROUTE REFER PIPING TO NEW CONDENSING UNIT ON ROOF. INSTALL APPROX (50) GRD'S AND MISC DUCT WORK Use: Residential: New .......... ❑ Replacement ........ ❑ Commercial: New .......... Replacement ........ ❑ Fuel Type: Electric..... ® Gas ....... ❑ Other: H?Applicat ions\Ponns-Applications On Linc\2016 ApplieationsWechnnical Permit Application Revised 1.4-16.docx Revised: January 2016 Page] oil bh Indicate type of mechanical work being installed and the quantity below: Unit Type Qty Furnace <100k btu Residential, Nighttime Furnace >I 00k btu 50 Floor furnace 55 dB(A) Suspended/wall/floor mounted heater 57 dB(A) Appliance vent Commercial Repair or addition to heat/refrig/cooling System 1 Air handling unit <I0,000 cfm 65 dB(A) Unit Type Qty Air handling unit >I0,000 cfm Residential, Nighttime Evaporator cooler 50 Ventilation fan connected to single duct 55 dB(A) Ventilation system 57 dB(A) Hood and duct Commercial Incinerator — domestic 1 Incinerator — comm/industrial 65 dB(A) Unit Type Qty Fire damper Residential, Nighttime Diffuser 50 Thermostat 55 dB(A) Wood/gas stove 57 dB(A) Emergency enerator Commercial Other mechanical equipment 1 60 dB(A) 65 dB(A) Boiler/Compressor Qty 0-3 hp/100,000 btu 3-15hp/500,000 btu 15-30 hp/1,000,000 btu 30-50 hp/1,750,000 btu 50+ It /1,750,000 btu Noise: Mechanical units need to be in compliance with the Tukwila Noise Code. Maximum permissible sound levels are based on from where the sound is created and where the sound is heard. Additionally, if sound can be heard from within a house at night in a residential zone it may not be allowed. For more details, see TMC 8.22 District of Sound Producing Source District of Receiving Property Residential, Daytime* Residential, Nighttime Commercial Industrial Residential 55 dB(A) 45 dB(A) 57 dB(A) 60 dB(A) Commercial 57 dB(A) 47 dB(A) 60 dB(A) 65 dB(A) Industrial 60 dB(A) 50 dB(A) 65 dB(A) 70 dB(A) *Daytime means 7A1V1-1 OPM, Monday through Friday and 8AM-1 OPM, Saturday, Sunday and State -recognized holidays. A few sounds are exempt from the noise code, including: Warning devices; Construction and property maintenance during the daytime hours (lam-IOpm); Testing of backup generators during the day. PERMIT APPLICATION NOTES - Value of construction — in all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the permit center to comply with current fee schedules. Expiration of plan review — applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The building official may grant one extension of time for additional periods not to exceed 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). I HEREBY CERTIFY THAT 1 HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. Date: 04/12/2016 Print Name: DARLA DOLL Day Telephone: (206) 768-4278 Mailing Address: 7717 DETROIT AVE SW SEATTLE WA 98106 City State Zip H:AApplicmions\Forms-Applications On LineA2016 ApplicationsWechanical Permit Application Revised 1-4-16.docx Revised: Innuary 201 6 Page 2 of 2 bh Date Paid: Tuesday, April 12, 2016 Paid By: MACDONALD MILLER Pay Method: CHECK 4463 Printed: Tuesday, April 12, 2016 12:51 PM 1 of 1 (77! SYSTEMS INSPECTION RECORD Retain a copy with permit r:5-- 0111-) INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Pr 'ect: Type oinspection:� R�.\ 1 (P� Acl(dr®� �� J� Gq W Date galled: pa Special Instructions: M Dat a ted: a.m. -% p.m. Regyester: ( Phone No: '7,0r 6g6q Approved per applicable codes. Corrections required prior to approval. COMMENTS: AAA L Inspector: Date: REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit IMP,KTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Pqq t I A TYPe sp ctio Address: � Pr � �te Called: Special Instructions: A-141/ e Wanted:a.m. �` 16 p.m. Reque6ter: Phone No: ❑ Approved per applicable codes. 1 Corrections required prior to approval. 5 Inspector: Date: / REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. INSPECTION RECORD n3 Retain a copy with permit 6 r ©oS3 NSKCTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project: Type If lnspe tion;-� A dress: 03 S G� wc� V �V Date alle : i Special Instructions: Date Wanted, a.m. �.f (,6 p.m. ` Requester.-- Phone No: pector: �/� Date` _/ ,_ El REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. 0 It, - 003 7 t"-' INSPECTION RECORD Retain a copy with permit Alk SPELTION N0. PERMIT N0. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Pro'ect: Type of I action: K/�cl �{ Address: �Q71� late CacJ��ed: Special Instructions: T,6 l`lI /� � �� j �(✓� e Wanted:��� a.m. p.m. Requester: Phone No: Inspector: Date: REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. 2 INSPECTION RECORD -06 � i Retain a copy with permit 16 SPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Pree r Type of Inspection: Address: Date Cal Special Instructions:A"tat WLnt-pd 1,6 a.m. J / p.m. Requester: Phone No: '! F] Approved per applicable codes. 1-1 Corrections required prior to approval. V CJ, IInspector: IDate: 6-- J 7 —/)G REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. MacDonald -Miller FACILITY SOLUTIONS TABB CERTIFIED TESTING AND BALANCING REPORT FOR BECU — GATEWAY 9 TI MM#73166234 13035 GATEWAY DRIVE SEATTLE WA 98168 ENGINEER OF RECORD — MMFS AM TCS""*. A0AMTKO AND YAIANCIND DDRCAD T11@ %tbPEttl6pA�•A CMbtC@•• THE DATA PRESENTED IN THIS REPORT IS A RECORD OF SYSTEM MEASUREMENTS AND FINAL ADJUSTMENTSTHAT HAVE BEEN OBTAINED IN ACCORDANCE WITH THE CURRENT EDITION OF THE TABB PROCEDURAL STANDARDS FOR TESTING, ADJUSTING, AND BALANCING OF ENVIRONMENTAL/DOMESTIC SYSTEMS. ANY VARIANCES FROM DESIGN QUANTITIES, .WHICH EXCEED TOLERANCES, ARE NOTED IN THE TEST -ADJUST - BALANCE REPORT PROJECT SUMMARY. THIS REPORT AND THE WORK IT REPRESENTS IS WARRIENTIED FOR AND EXPIRES 1 YEAR FROM REPORT DATE UNLESS OTHERWISE STATED IN CONTRACT DOCUMENTS SUBMITTED & CERTIFIED BY: MR BRADLEY SHARP, TABB SUPERVISOR REPORT DATE: JUNE 29, 2016 Certification Expiration Date: March 31, 2018 ��`o�a� Certifi�at�o o Bradley Sharp MacDonald Miller Facilities Solutions TABB Supervisor TB977756S March 31, 2018 RECEIVED CITY OF TUKWILA JUL 012016 PERMIT CENTER 7e]nted D1111,111.6 0 4L �ci Supe - I MACDONALD-MILLER FACILITY SOLUTIONS MECHANICAL SERVICES #2661 7717 DETROIT AVENUE SW SEATTLE, WASHINGTON 98106 PHONE: (206) 763-9400 FAX: (206) 767-6773 -.0110002"ft- AM MacDonald -Miller FACILITYSOLUTIONS TES U0, AOJVYT"O ANO OALANCINO OUREAU rns rrtoFi:s¢IONA�� cNolcrr TESTING REPORT SUMMARY — BECU Gateway 9 1) General Notes a) Testing was completed on June 29, 2016 b) TAB work was in accordance with TABB procedural standards. c) Inlet volumetric flow rates were measured by use of a calibrated Hotwire and Micro -Manometer d) Design information was obtained from mechanical drawings, submittals, specifications, or shop drawings as available. 2) Scope of work a) Test of the existing and new air distribution system on the floor - Outlet balance only b) Documentation of any deficiencies and to provide finding to the Customer/GC and Building 3) Description of the System a) Existing RTU x2 • RTU -1 —Constant volume package unit with 7 Carrier VVT's attached and bypass set to maintain .25" SP at all times • RTU -2 — Constant Volume package unit with diffusers • Existing duct with slight modification • Wall mounted thermostats • No evaluation of exhaust systems was in the balance scope 4) Evaluation Procedures Summarized a) HVAC system was inspected for general conditions, obvious deficiencies and verified ready to be tested b) Flow verification c) Equipment was in full use during the duration of the test d) Flows are -5/+10% unless otherwise noted e) Diversity was used to achieve the best results for the VVT System. Some boxes were closed 50% to simulate real world conditions 5) Findings a) See prints and added reports for specific information on the balance effort b) Unit received a new motor and will get additional drive improvements after bearing break-in is complete. Field Technician: Bradley Sharp (Test and Balance) — Brad.Sharp(a.macmiller.com MacDonald -Miller FACILITY SOLUTIONS ABBREVIATIONS AC AIR CONDITIONING UNIT HP HORSEPOWER BDD BACK DRAFT DAMPER HP HEAT PUMP AIR CONDITIONING UNIT BHP BRAKE HORSEPOWER HWM HEATING WATER RETURN B.S. BIRD SCREEN HWS HEATING WATER SUPPLY CEG CEILING EXHAUST GRILLE INAC INACCESSIBLE CRG CEILING RETURN GRILLE LAT (DB) LEAVING AIR TEMP. (DRY BULB) CFM CUBIC FEET PER MINUTE LAT (WB) LEAVING AIR TEMP. (WET BULB) CHWR CHILLED WATER RETURN LD LINEAR DIFFUSER CHWS CHILLED WATER SUPPLY LWT LEAVING WATER TEMPERATURE CSD CEILING SUPPLY DIFFUSER MAX MAXIMUM CWR CONDENSER WATER RETURN MIN MIMMUM CWS CONDENSER WATER SUPPLY O WIDE OPEN DAMPER / AIR PATH DD DIRECT DRIVE OBD OPPOSED BLADE DAMPER DP DIFFERENTIAL PRESSURE OD OUTSIDE DIAMETER DIFF DIFFUSER OSA OUTSIDE AIR DMPR DAMPER RA RETURN AIR DNA DATA NOT AVAILABLE REQ'D REQUIRED DNL DATA NOT LISTED RH RELATIVE HUMIDITY DNT DATA NOT TAKEN RTU ROOFTOP UNIT DWDI DOUBLE WIDTH DOUBLE INLET SA SUPPLY AIR EAT (DB) ENTERING AIR TEMP. (DRY BULB) SP STATIC PRESSURE EAT (WB) ENTERING AIR TEMP. (WET BULB) SWG SIDE WALL GRILLE EC EGG -CRATE RETURN SWR SIDE WALL REGISTER EF EXHAUST FAN SWSI SINGLE WIDTH SINGLE INLET EG EXHAUST GRILLE T OUTLET NEAREST THERMOSTAT ESP EXTERNAL STATIC PRESSURE TSP TOTAL STATIC PRESSURE EWT ENTERING WATER TEMPERATURE T.P. THERMALLY PROTECTED FPM FEET PER MINUTE T -STAT THERMOSTAT OR SENSOR FH FUME HOOD TYP TYPICAL GPM GALLONS PER MINUTE 0 VOLTAGE PHASE / DUCT DIAMETER HF HEPA FILTER V.D. VOLUME DAMPER Pg. I Iii=o MacDonald -Miller FACILITY SOLUTIONS MacDonald. Miller Facility Solutions Calibration Certification 201.6 Calibration Instrument Tool# Model# Serial# By Calibration Calibration Date Due Rotating Measurement 1016062 461895 H.308529 Tektronix 8/14/2015 8/14/2016 Temperature Measurement Air 1007258 52 Series 11 12570298 Tektronix 5/6/2015 5/6/2016 Temperature NSN Measurement H2O 80PK-5A Mac 63690 7458111 Tektronix 5/6/2015 5/6/2016 Electrical Measurement 1014102 Fluke 974 29310312WS Fluke 12/11/2014 12/11/2015 Temperature Measurement Air 1005253 ADM -860C M08305 Shortridge 12/12/2014 12/12/2015 Air Velocity Measurement 1016124 EBT731 EBT731524027 TSI/Alnore 6/12/2015 6/12/2016 Temperature Measurement Air 1016124 EBT731 EBT731524027 TSI/Alnore 6/12/2015 6/12/2016 Humidity 9555P1333018 Measurement 1005875 TSI 9555-P P08410045 TSI 8/25/2015 8/25/2016 Hydronic Pressure Measurement 1003731 HM670 70725068 TSI / Alnore 8/25/2015 8/25/2016 Hydronic Differential . Pressure Measurement 1016065 HM675 71523045 TSI / Alnore 7/2/2015 7/2/2016 Sound Meter QC -10 Calibrator 1005543 Calibrator QIH060366 3M 7/7/2015 7/7/2016 9/2/2015 �Z=MacDonald -Milner FACILITY SOLUTIONS Roof Top Unit PROJECT: BECU- Gateway 9 DATE: 6/30/2016 LOCATION: South Center, WA CONTACT: Brad Sharp PROJECT #: 73166234 SYSTEM/UNIT: RTU -01 AREA: 2nd FI SYSTEM/UNIT: RTU-01/VVT-201 AREA: 2nd FI RTU-01/VVT-201 Supply Outlet Summary Motor Data RTU-01/Suaoly Fan Motor Hertz 60 Hz Term Box Test Data Max Design CFM 1550 CFM Max Actual CFM 1415 CFM System/Unit TIO Unit Data Manufacturer Carrier Model Number Pinch VVT Serial Number NA VAV Address 1 Box Inlet Size 16 K Factor 1 RTU-01/VVT-201 Supply Outlet Summary Motor Data RTU-01/Suaoly Fan Motor Hertz 60 Hz Term Box Test Data Max Design CFM 1550 CFM Max Actual CFM 1415 CFM System/Unit TIO Type of Reading Outlet Type Size Design Reading Prelim Reading % Pre Final Reading % Final Outlet -01 Flowhood CSD 10 310 165 53 280 90 Outlet -02 Flowhood CSD 10 310 155 50 285 92 Outlet -03 Flowhood CSD 10 310 135 44 290 94 Outlet -04 Flowhood CSD 10 310 190 61 280 90 Outlet -05 Flowhood CSO 10 310 145 47 280 90 Totals: - - - - 1550 790 51 1415 91 SYSTEM/UNIT: RTU-0INVT-202 AREA: 2nd FI RTU-01/VVT-202 Supply Outlet Summary Term Box Test Data Max Design CFM 1110 CFM Max Actual CFM 1050 CFM System/Unit TIO Unit Data Manufacturer Carrier Model Number Pinch VVT Serial Number NA VAV Address 2 Box inlet Size 12 K Factor 1 RTU-01/VVT-202 Supply Outlet Summary Term Box Test Data Max Design CFM 1110 CFM Max Actual CFM 1050 CFM System/Unit TIO Type of Reading Outlet Type Size Design Reading Prelim Reading % Pre Final Readin % Final Outlet -01 Flowhood CSD 10 265 190 72 255 96 Outlet -02 Flowhood CSD 10 265 290 109 250 94 Outlet -03 Flowhood CSD 10 265 310 117 250 94 Outlet -04 Flowhood CSD 10 265 155 58 245 92 Outlet -05 Flowhood CSD 6 50 140 280 50 100 Totals: - - - - 1110 1085 98 1050 95 MacDonald -Miller Page 1 of 4 (9n)MacDonald -Miller FACILITY SOLUTIONS Roof Top Unit PROJECT: BECU- Gateway 9 DATE: 6/30/2016 LOCATION: South Center, WA CONTACT: Brad Sharp PROJECT #: 73166234 SYSTEM/UNIT: RTU-01NVT-203 AREA: 2nd FI RTU-01/VVT-203 Supply Outlet Summary Term Box Test Data Max Design CFM 1100 CFM Max Actual CFM 1020 CFM System/Unit TIO Unit Data Manufacturer Carrier Model Number Pinch WT Serial Number NA VAV Address 3 Box Inlet Size 12 K Factor 1 RTU-01/VVT-203 Supply Outlet Summary Term Box Test Data Max Design CFM 1100 CFM Max Actual CFM 1020 CFM System/Unit TIO Type of Reading Outlet Type Size Design Reading Prelim Reading % Pre Final Reading % Final Outlet -01 Flowhood CSD 10 220 95 43 200 91 Outlet -02 Flowhood CSD 10 220 210 95 205 93 Outlet -03 Flowhood CSD 10 220 215 98 200 91 Outlet -04 Flowhood CSD 10 220 190 86 210 95 Outlet -05 Flowhood CSD 10 220 185 84 205 93 Totals: - - - - 1100 1 895 81 1 1020 93 SYSTEM/UNIT: RTU-01IVVT-204 AREA: 2nd FI RTU-01/VVT-204 Supply Outlet Summary Term Box Test Data Max Design CFM 1100 CFM Max Actual CFM 1015 CFM System/Unit T/O Unit Data Manufacturer Carrier Model Number Pinch VVT Serial Number NA VAV Address 4 Box Inlet Size 12 K Factor 1 RTU-01/VVT-204 Supply Outlet Summary Term Box Test Data Max Design CFM 1100 CFM Max Actual CFM 1015 CFM System/Unit T/O Type of Reading Outlet Type Size Design Reading Prelim Reading % Pre Final Reading % Final Outlet -01 Flowhood CSD 10 275 65 24 245 89 Outlet -02 Flowhood CSD 10 275 175 64 255 93 Outlet -03 Flowhood CSD 10 275 235 85 260 95 Outlet -04 Flowhood CSD 10 275 300 109 255 93 Totals: - - - - 1100 1 775 70 1 1015 1 92 MacDonald -Miller Page 2 of 4 IMalcDoneid-Mil er FACILITY SOLUTIONS Roof Top Unit PROJECT: BECU- Gateway 9 DATE: 6/30/2016 LOCATION: South Center, WA CONTACT: Brad Sharp PROJECT #: 73166234 SYSTEM/UNIT: RTU-01/VVT-205 AREA: 2nd FI RTU-01/VVT-205 Supply Outlet Summary Tenn Box Test Data Max Design CFM 980 CFM Max Actual CFM 930 CFM System/Unit T/O Unit Data Manufacturer Carrier Model Number Pinch VVT Serial Number NA VAV Address 5 Box Inlet Size 12 K Factor 1 RTU-01/VVT-205 Supply Outlet Summary Tenn Box Test Data Max Design CFM 980 CFM Max Actual CFM 930 CFM System/Unit T/O Type of Reading Outlet Type Size Design Reading Prelim Reading % Pre Final Reading % Final Outlet -01 Flowhood CSD 10 245 305 124 230 94 Outlet -02 Flowhood CSD 10 245 240 98 230 94 Outlet -03 Flowhood CSD 10 245 140 57 230 94 Outlet -04 Flowhood CSD 10 245 1 145 1 59 240 98 Totals: - - - - 980 1 830 1 85 930 95 SYSTEM/UNIT: RTU-01/VVT-206• AREA: 2nd FI RTU-01/VVT-206 Supply Outlet Summary Tenn Box Test Data Max Design CFM 495 CFM Max Actual CFM 460 CFM System/Unit TIO Unit Data Manufacturer Carrier Model Number Pinch WT Serial Number NA VAV Address 6 Box Inlet Size 12 K Factor 1 RTU-01/VVT-206 Supply Outlet Summary Tenn Box Test Data Max Design CFM 495 CFM Max Actual CFM 460 CFM System/Unit TIO Type of Reading Outlet Size Type Design Reading Prelim Reading % Pre Final Reading % Final Outlet -01 Flowhood CSD 12 410 190 46 385 94 Outlet -02 Flowhood CSD 6 85 200 235 75 88 Totals: - - - - 495 390 79 460 93 MacDonald -Miller Page 3 of 4 (9n)MacDonald -Miller FACILITY SOLUTIONS Roof Top Unit PROJECT: BECU- Gateway 9 DATE: 6/30/2016 LOCATION: South Center, WA CONTACT: Brad Sharp PROJECT #: 73166234 SYSTEM/UNIT: RTU-01/WT-207 AREA: 2nd FI RTU-0INVT-207 Supply Outlet Summary Term Box Test Data Max Design CFM 995 CFM Max Actual CFM 930 CFM System/Unit TIO Unit Data Manufacturer Carrier Model Number Pinch VVT Serial Number NA VAV Address 7 Box Inlet Size 12 K Factor 1 RTU-0INVT-207 Supply Outlet Summary Term Box Test Data Max Design CFM 995 CFM Max Actual CFM 930 CFM System/Unit TIO Type of Reading Outlet Type Size Design Reading Prelim Reading % Pre Final Reading % Final Outlet -01 Flowhood CSD 10 320 200 63 290 91 Outlet -02 Flowhood CSD 10 210 175 83 195 93 Outlet -03 Flowhood CSD 10 210 85 40 195 93 Outlet -04 Flowhood CSD 10 255 190 75 250 98 Totals: - - - - 995 1 650 65 930 93 SYSTEM/UNIT: RTU -02 AREA: 2nd FI . Motor Data RTU-02/Supply Fan Motor Hertz 60 Hz RTU -02 Supply Outlet Summary System/Unit TIO Type of Readina Outlet Type Size Design Reading Prelim Readina % Pre Final Readin % Final Outlet -01 Flowhood CSD 8 160 145 91 145 91 Outlet -02 Flowhood CSD 8 160 100 63 140 88 Outlet -03 Flowhood CSD 8 290 245 84 260 90 Outlet -04 Flowhood CSD 8 290 150 52 260 90 Outlet -05 Flowhood CSD 10 150 165 110 135 90 Outlet -06 Flowhood CSD 10 150 160 107 140 93 Outlet -07 Flowhood CSD 6 50 200 400 50 100 Outlet -08 Flowhood CSD 10 250 210 84 220 88 Totals: - - - 1500 1 1375 92 1350 90 MacDonald -Miller Page 4 of 4 n ■ 11-1:110 B GATEWAY BLDG 9 - BECU TI �1 u� Si i 13939 GATEWAY DR - - - - CU O' 8 TUKYAL4 WA 99188 - - - - MacDonald -Miller N o m1 I 1. VAC' am si99m rsn a'w,rz �wo9s. arz nwA u�nn: uncoovsa9murz .. g g ISSUED FOR CONSTRUCTION Project Name: Dataset Name: Location: Building Owner: Program User: Company: Comments: Cooling Design Period: Peak Hour Override: Daylight Savings Period: Summer Period: Entered Values TRACE® 700 version 6.3.2 By MACDONALD-MILLER BECU C:\Users\vandoorent\Documents\TRACE 700 Projects\Gateway Bldg 9\GTWYBECU.TRC TUKWILA, WA January thru December 0 Cooling Methodology: CLTD-CLF (ASHRAE TFM) Heating Methodology: UATD Infiltration Methodology: Vary with wind speed Outside Film Methodology: Vary with wind speed Terrain Methodology: Center of a large city Room Circ Rate: Medium Wall Load To Plenum: YES Building Orientation: 0 degrees from north Simulation Hours: Reduced year Calendar Code: Standard (1978) Energy Simulation Period: January thru December P -T 0 [L [E Location: Seattle, WA Summer Design Dry Bulb: 82.00 °F Summer Design Wet Bulb: 65.00 °F Winter Design Dry Bulb: 24.00 °F Summer Clearness Number: 0.92 Winter Clearness Number: 0.87 REVIEWED FOR CODE COMPLIANCE APPROVED MAY 0 5 2016 City of Tukdila BUILDING DIVISION Summer Ground Reflectance: 0.20 Winter Ground Reflectance: 0.20 Carbon Dioxide Level: 400 ppm Force VAV Min => Nominal Ventilation at Design: No Allow Energy Recovery/Transfer at Design: No Retest Design Peaks: Yes Calculate Building Block Loads: Yes RECEIVED CITY OF TUKWILA Close ventilation dampers during unoccupied hours: Yes 04, 1 LQ 4f Project Name: BECU Dataset Name: C:\Users\vandoorent\Documents\TRACE 700 Projects\Gateway Bldg 9\GTWYBECU.TRC `r,� ]d A _ s +i 1 2^J1r 6 3 PERMIT CENTER TRACED 700 v6.3.2 Entered Values - Project Information Room Checksums By MACDONALD-MILLER 200 Breakout COOLING COIL SELECTION Total Capacity Sens Cap. Coil Airflow Enter DB/WB/HR ton MBh MBh cfm °F °F gr/Ib Main CIg 0.8 9.7 8.8 341 76.5 61.1 55.5 Aux CIg 0.0 0.0 0.0 0 0.0 0.0 0.0 Opt Vent 0.0 0.0 0.0 0 0.0 0.0 0.0 Total 0.8 9.7 Project Name: BECU Dataset Name: GTWYBECU.TRC Leave DB/WB/HR °F °F gr/Ib 53.8 51.0 51.1 0.0 0.0 0.0 0.0 0.0 0.0 COOLING COIL PEAK CLG SPACE PEAK Gross Total HEATING COIL PEAK TEMPERATURES Peaked at Time: Mo/Hr: 7/18 Mo/Hr: 7 / 18 kux Htg Mo/Hr: Heating Design 0.0 'reheat Cooling Heating Outside Air: OADB/WB/HR: 78 / 64 / 67 0.0 OADB: 78 0 OADB: 24 Wall SADB 55.0 80.8 Ext Door 0 0 0 Ra Plenum 75.7 69.8 Space Plenum Net Percent Space Percent Space Peak Coil Peak Percent Return 75.7 69.8 Sens. + Lat. Sens. + Lat Total Of Total Sensible Of Total Space Sens Tot Sens Of Total Ret/OA 75.9 64.2 Btu/h Btu/h Btu/h (%) Btu/h (%) Btu/h Btu/h (%) Fn MtrTD 0.2 0.0 Envelope Loads Envelope Loads Fn BIdTD 0.4 0.0 Skylite Solar 0 0 0 0 0 0 Skylite Solar 0 0 0.00 Fn Frict 1.3 0.0 Skylite Cond 0 0 0 0 0 0 Skylite Cond 0 0 0.00 Roof Cond 0 0 0 0 0 0 Roof Cond 0 0 0.00 Glass Solar 5,294 0 5,294 54 5,294 69 Glass Solar 0 0 0.00 AIRFLOWS Glass/Door Cond 102 0 102 1 102 1 Glass/Door Cond -2,171 -2,171 34.29 Cooling Heating Wall Cond 402 261 663 7 402 5 Wall Cond -445 -738 11.65 Partition/Door 0 0 0 0 0 Partition/Door 0 0 0.00 Diffuser 341 341 Floor 0 0 0 0 0 Floor 0 0 0.00 Terminal 341 341 Adjacent Floor 0 0 0 0 0 0 Adjacent Floor 0 0 0.00 Main Fan 341 341 Infiltration 172 172 2 43 1 Infiltration -716 -716 11.31 Sec Fan 0 0 Sub Total =_> 5,970 261 6,231 64 5,841 77 Sub Total =_> -3,333 -3,626 57.25 Nom Vent 42 42 AHU Vent 42 42 Internal Loads Internal Loads Infil 14 14 Lights 836 209 1,044 11 836 11 Lights 0 0 0.00 MinStop/Rh 0 0 People 753 0 753 8 378 5 People 0 0 0.00 Return 355 355 Misc 500 0 500 5 500 7 Misc -765 -765 12.08 Exhaust 56 56 Sub Total =_> 2,088 209 2,297 24 1,713 22 Sub Total ==> -765 -765 12.08 Rm Exh 0 0 Auxiliary 0 0 Ceiling Load 66 -66 0 0 66 1 Ceiling Load -20 0 0.00 Leakage Dwn 0 0 Ventilation Load 0 0 516 5 0 0 Ventilation Load 0 -2,146 33.88 Leakage Ups 0 0 Adj Air Trans Heat 0 0 0 0 0 Adj Air Trans Heat 0 0 0 Dehumid. Ov Sizing 0 0 Ov/Undr Sizing 0 0 0.00 Ov/Undr Sizing 6 6 0 6 0 Exhaust Heat 13 -0.20 ENGINEERING CKS Exhaust Heat -42 -42 0 OA Preheat Diff. 0 0.00 Sup. Fan Heat 707 7 RA Preheat Diff. 0 0.00 Cooling Heating Ret. Fan Heat 0 0 0 Additional Reheat 0 0.00 % OA 12.2 12.2 Duct Heat Pkup 0 0 0 System Plenum Heat 190 -3.00 cfm/ft' 1.11 1.11 Underflr Sup Ht Pkup 0 0 Underfir Sup Ht Pkup 0 0.00 cfm/ton 421.09 Supply Air Leakage 0 0 0 Supply Air Leakage 0 0.00 ft'/ton 378.01 Btu/heft' 31.75 -20.70 Grand Total ==> 8,130 361 9,714 100.00 7,626 100.00 Grand Total ==> -4,118 -6,333 100.00 No. People 3.0 9.8/1000 ft' COOLING COIL SELECTION Total Capacity Sens Cap. Coil Airflow Enter DB/WB/HR ton MBh MBh cfm °F °F gr/Ib Main CIg 0.8 9.7 8.8 341 76.5 61.1 55.5 Aux CIg 0.0 0.0 0.0 0 0.0 0.0 0.0 Opt Vent 0.0 0.0 0.0 0 0.0 0.0 0.0 Total 0.8 9.7 Project Name: BECU Dataset Name: GTWYBECU.TRC Leave DB/WB/HR °F °F gr/Ib 53.8 51.0 51.1 0.0 0.0 0.0 0.0 0.0 0.0 TRACE& 700 v6.3.2 calculated at 10:11 AM on 04/08/2016 Alternative - 1 System Checksums Report Page 1 of 16 AREAS Capacity Coil Airflow Gross Total Glass MBh cfm °F ft' Aain Htg Floor 306 80.8 kux Htg Part 0 0.0 'reheat Int Door 0 0.0 tumidif ExFlr 0 0.0 )pt Vent Roof 0 0 0 Wall 367 116 32 Ext Door 0 0 0 TRACE& 700 v6.3.2 calculated at 10:11 AM on 04/08/2016 Alternative - 1 System Checksums Report Page 1 of 16 HEATING COIL SELECTION Capacity Coil Airflow Ent Lvg MBh cfm °F °F Aain Htg -6.3 341 64.2 80.8 kux Htg 0.0 0 0.0 0.0 'reheat 0.0 0 0.0 0.0 tumidif 0.0 0 0.0 0.0 )pt Vent 0.0 0 0.0 0.0 otal -6.3 TRACE& 700 v6.3.2 calculated at 10:11 AM on 04/08/2016 Alternative - 1 System Checksums Report Page 1 of 16 Room Checksums By MACDONALD-MILLER 201 Quiet Room Total 0.1 1.6 Project Name: BECU Dataset Name: GTWYBECU.TRC Leave DB/WB/HR 'F °F gr/Ib 53.8 51.3 52.3 0.0 0.0 0.0 0.0 0.0 0.0 AREAS COOLING COIL PEAK Cooling Total Capacity CLG SPACE PEAK Enter OB/WB/HR HEATING COIL PEAK MBh cfm Peaked at Time: Mo/Hr: 7/19 Mo/Hr: 6 / 19 Aux Clg 0.0 0.0 Mo/Hr: Heating Design 0.0 Outside Air: OADB/WB/HR: 75 / 63 / 67 0 OADB: 71 23 OADB: 24 0 0 Space Plenum Net Percent Space Percent 0 Space Peak Coil Peak Percent 0 Sens. + Lat. Sens. + Lat Total Of Total Sensible Of Total Space Sens Tot Sens Of Total Btu/h Btu/h Btu/h (%) Btu/h (%) Btu/h Btu/h I%) Envelope Loads Envelope Loads Skylite Solar 0 0 0 0 0 0 Skylite Solar 0 0 0.00 Skylite Cond 0 0 0 0 0 0 Skylite Cond 0 0 0.00 Roof Cond 0 0 0 0 0 0 Roof Cond 0 0 0.00 Glass Solar 938 0 938 57 1,024 80 Glass Solar 0 0 0.00 Glass/Door Cond 3 0 3 0 -39 -3 Glass/Door Cond -431 -431 36.82 Wall Cond 78 50 128 8 72 6 Wall Cond -91 -150 12.83 Partition/Door 0 0 0 0 0 Partition/Door 0 0 0.00 Floor 0 0 0 0 0 Floor 0 0 0.00 Adjacent Floor 0 0 0 0 0 0 Adjacent Floor 0 0 0.00 Infiltration 14 14 1 -8 -1 Infiltration -84 -84 7.20 Sub Total =_> 1,033 50 1,082 66 1,049 82 Sub Total =_> -606 -665 56.85 Internal Loads Internal Loads Lights 98 25 123 7 98 8 Lights 0 0 0.00 People 250 0 250 15 125 10 People 0 0 0.00 Misc 0 0 0 0 0 0 Misc -90 -90 7.69 Sub Total =_> 348 25 373 23 223 17 Sub Total =_> -90 -90 7.69 Ceiling Load 8 -8 0 0 7 1 Ceiling Load -2 0 0.00 Ventilation Load 0 0 74 5 0 0 Ventilation Load 0 -461 39.35 Adj Air Trans Heat 0 0 0 0 0 Adj Air Trans Heat 0 0 0 Dehumid. Ov Sizing 0 0 Ov/Undr Sizing 0 0 0.00 Ov/Undr Sizing 1 1 0 1 0 Exhaust Heat 2 -0.21 Exhaust Heat -8 -8 0 OA Preheat Diff. 0 0.00 Sup. Fan Heat 119 7 RA Preheat Diff. 0 0.00 Ret. Fan Heat 0 0 0 Additional Reheat 0 0.00 Duct Heat Pkup 0 0 0 System Plenum Heat 43 -3.67 Underflr Sup Ht Pkup 0 0 Underflr Sup Ht Pkup 0 0.00 Supply Air Leakage 0 0 0 Supply Air Leakage 0 0.00 Grand Total ==> 1,389 59 1,641 100.00 1,281 100.00 Grand Total ==> -699 -1,170 100.00 Total 0.1 1.6 Project Name: BECU Dataset Name: GTWYBECU.TRC Leave DB/WB/HR 'F °F gr/Ib 53.8 51.3 52.3 0.0 0.0 0.0 0.0 0.0 0.0 AREAS COOLING COIL SELECTION Cooling Total Capacity Sens Cap. Coil Airflow Enter OB/WB/HR ton MBh MBh cfm 'F 'F gr/Ib Main Clg 0.1 1.6 1.4 57 76.2 61.4 57.4 Aux Clg 0.0 0.0 0.0 0 0.0 0.0 0.0 Opt Vent 0.0 0.0 0.0 0 0.0 0.0 0.0 Total 0.1 1.6 Project Name: BECU Dataset Name: GTWYBECU.TRC Leave DB/WB/HR 'F °F gr/Ib 53.8 51.3 52.3 0.0 0.0 0.0 0.0 0.0 0.0 AREAS HEATING COIL SELECTION Cooling Gross Total Glass 55.0 80.9 ft' I%) Floor 36 Return 75.7 Part 0 Ret/OA 75.6 Int Door 0 Fn MtrTD 0.2 ExFlr 0 Fn BIdTD 0.4 Roof 0 0 0 Wall 74 23 31 Ext Door 0 0 0 TEMPERATURES HEATING COIL SELECTION Cooling Heating SADB 55.0 80.9 Ra Plenum 75.7 69.8 Return 75.7 69.8 Ret/OA 75.6 62.6 Fn MtrTD 0.2 0.0 Fn BIdTD 0.4 0.0 Fn Frict 1.3 0.0 AIRFLOWS HEATING COIL SELECTION Cooling Cooling Heating Diffuser 57 57 Terminal 57 57', Main Fan 57 57 Sec Fan 0 0 Nom Vent 9 9 AHU Vent 9 9 Infil 2 2 MinStop/Rh 0 0 Return 59 59 Exhaust 11 11 Rm Exh 0 0 Auxiliary 0 0 Leakage Dwn 0 0 Leakage Ups 0 0 ENGINEERING CKS HEATING COIL SELECTION Cooling Heating OA 15.6 15.6 cfm/ft' 1.59 1.59 cfm/ton 418.71 -1.2 57 ft'/ton 263.30 x Htg Btu/heft' 45.58 -32.51 No. People 1.0 27.8/1000 ft' TRACE® 700 v6.3.2 calculated at 10:11 AM on 04/08/2016 Alternative - 1 System Checksums Report Page 2 of 16 HEATING COIL SELECTION Capacity Coil Airflow Ent Lvg MBh cfm 'F °F, in Htg -1.2 57 62.6 80.9 x Htg 0.0 0 0.0 0.0 !heat 0.0 0 0.0 0.0 midif 0.0 0 0.0 0.0 It Vent 0.0 0 0.0 0.0 tal -1.2 TRACE® 700 v6.3.2 calculated at 10:11 AM on 04/08/2016 Alternative - 1 System Checksums Report Page 2 of 16 Room Checksums By MACDONALD-MILLER 202a Open Office COOLING COIL PEAK COOLING COIL SELECTION CLG SPACE PEAK Sens Cap. Coil Airflow HEATING COIL PEAK ton MBh TEMPERATURES °F °F Peaked at Time: Mo/Hr: 7/18 Mo/Hr: 6 / 19 0.0 0.0 Mo/Hr: Heating Design 0.0 0 0.0 0.0 Cooling Heating Outside Air: OADB/WB/HR: 78 / 64 / 67 36 OADB: 71 0 OADB: 24 -7.7 SADB 55.0 78.6 Ra Plenum 75.7 69.8 Space Plenum Net Percent Space Percent Space Peak Coil Peak Percent Return 75.7 69.8 Sens. + Lat. Sens. + Lat Total Of Total Sensible Of Total Space Sens Tot Sens Of Total Ret/OA 76.0 62.7 Btu/h Btu/h Btu/h (%) Btu/h (%) Btu/h Btu/h (%) Fn MtrTD 0.2 0.0 Envelope Loads Envelope Loads Fn 13IdTD 0.4 0.0 Skylite Solar 0 0 0 0 0 0 Skylite Solar 0 0 0.00 Fn Frict 1.3 0.0 Skylite Cond 0 0 0 0 0 0 Skylite Cond 0 0 0.00 Roof Cond 0 0 0 0 0 0 Roof Cond 0 0 0.00 Glass Solar 4,182 0 4,182 34 4,780 49 Glass Solar 0 0 0.00 AIRFLOWS Glass/Door Cond Wall Cond 92 223 0 162 92 385 1 3 -166 244 -2 3 Glass/Door Cond Wall Cond -1,909 -305 -1,909 -530 24.80 6.88 Cooling Heating Partition/Door 0 0 0 0 0 Partition/Door 0 0 0.00 Diffuser 433 433 Floor 0 0 0 0 0 Floor 0 0 0.00 Terminal 433 433 Adjacent Floor 0 0 0 0 0 0 Adjacent Floor 0 0 0.00 Main Fan 433 433 Infiltration 216 216 2 -90 -1 Infiltration -927 -927 12.04 Sec Fan 0 0 Sub Total =_> 4,714 162 4,876 39 4,768 49 Sub Total =_> -3,142 -3,367 43.72 Nom Vent 67 67 AHU Vent 67 67 Internal Loads Internal Loads Infil 18 18 Lights 1,081 270 1,352 11 1,081 11 Lights 0 0 0.00 MinStop/Rh 0 0 People 1,508 0 1,508 12 757 8 People 0 0 0.00 Return 451 451 Misc 3,000 0 3,000 24 3,000 31 Misc -990 -990 12.86 Exhaust 85 85 Sub Total =_> 5,589 270 5,860 47 4,838 50 Sub Total =_> -990 -990 12.86 Rm Exh 0 0 Auxiliary 0 0 Ceiling Load 86 -86 0 0 82 1 Ceiling Load -26 0 0.00 Leakage Dwn 0 0 Ventilation Load 0 0 805 6 0 0 Ventilation Load 0 -3,458 44.90 Leakage Ups 0 0 Adj Air Trans Heat 0 0 0 0 0 Adj Air Trans Heat 0 0 0 Dehumid. Ov Sizing 0 0 Ov/Undr Sizing 0 0 0.00 Ov/Undr Sizing 7 7 0 7 0 Exhaust Heat 20 -0.26 ENGINEERING CKS Exhaust Heat -65 -65 -1 OA Preheat Diff. 0 0.00 Sup. Fan Heat 899 7 RA Preheat Diff. 0 0.00 Cooling Heating Ret. Fan Heat 0 0 0 Additional Reheat 0 0.00 % OA 15.5 15.5 Duct Heat Pkup 0 0 0 System Plenum Heat 94 -1.22 cfm/ft' 1.09 1.09 Underflr Sup Ht Pkup 0 0 Underflr Sup Ht Pkup 0 0.00 cfm/ton 420.05 Supply Air Leakage 0 0 0 Supply Air Leakage 0 0.00 ft'/ton 383.80 Btu/heft' 31.27 -19.44 Grand Total ==> 10,396 282 12,381 100.00 9,695 100.00 Grand Total ==> -4,158 -7,700 100.00 No. People 6.0 15.2/1000 ft' Total 1.0 12.4 Project Name: BECU Dataset Name: GTWYBECU.TRC Leave DB/WB/HR 'F °F gr/Ib 53.8 51.3 52.0 0.0 0.0 0.0 0.0 0.0 0.0 AREAS COOLING COIL SELECTION Total Capacity Sens Cap. Coil Airflow Enter DBfWB/HR ton MBh MBh cfm °F °F gr/Ib Main Clg 1.0 12.4 10.9 433 76.6 61.3 56.4 Aux Clg 0.0 0.0 0.0 0 0.0 0.0 0.0 Opt Vent 0.0 0.0 0.0 0 0.0 0.0 0.0 Total 1.0 12.4 Project Name: BECU Dataset Name: GTWYBECU.TRC Leave DB/WB/HR 'F °F gr/Ib 53.8 51.3 52.0 0.0 0.0 0.0 0.0 0.0 0.0 AREAS HEATING COIL SELECTION Gross Total Glass Ent Lvg ft' (�) Floor 396 °F Htg Part 0 62.7 78.6 Int Door 0 0.0 0 0.0 ExFlr 0 eat 0.0 0 Roof 0 0 0 Wall 282 102 36 Ext Door 0 0 0 TRACE® 700 v6.3.2 calculated at 10:11 AM on 04/08/2016 Alternative - 1 System Checksums Report Page 3 of 16 HEATING COIL SELECTION Capacity Coil Airflow Ent Lvg MBh cfm °F °F Htg -7.7 433 62.7 78.6 Htg 0.0 0 0.0 0.0 eat 0.0 0 0.0 0.0 idif 0.0 0 0.0 0.0 dent 0.0 0 0.0 0.0 I -7.7 TRACE® 700 v6.3.2 calculated at 10:11 AM on 04/08/2016 Alternative - 1 System Checksums Report Page 3 of 16 Room Checksums By MACDONALD-MILLER 202b Open Office COOLING COIL PEAK COOLING COIL SELECTION Cooling CLG SPACE PEAK Sens Cap. HEATING COIL PEAK Enter DB/WB/HR Peaked at Time: Mo/Hr: 7 / 16 gr/Ib Mo/Hr: 8 / 16 408 Mo/Hr: Heating Design Aux Clg 0.0 0.0 Outside Air: OADB/WB/HR: 81 / 65 / 66 OADB: 81 0 OADB: 24 0 Roof Space Plenum Net Percent Space Percent 0 Space Peak Coil Peak Percent 0 Sens. + Lat. Sens. + Lat Total Of Total Sensible Of Total 0 Space Sens Tot Sens Of Total Btu/h Btu/h Btu/h (%) Btu/h (%) Btu/h Btu/h Envelope Loads Envelope Loads Skylite Solar 0 0 0 0 0 0 Skylite Solar 0 0 0.00 Skylite Cond 0 0 0 0 0 0 Skylite Cond 0 0 0.00 Roof Cond 0 0 0 0 0 0 Roof Cond 0 0 0.00 Glass Solar 0 0 0 0 0 0 Glass Solar 0 0 0.00 Glass/Door Cond 0 0 0 0 0 0 Glass/Door Cond 0 0 0.00 Wall Cond 0 0 0 0 0 0 Wall Cond 0 0 0.00 Partition/Door 0 0 0 0 0 Partition/Door 0 0 0.00 Floor 0 0 0 0 0 Floor 0 0 0.00 Adjacent Floor 0 0 0 0 0 0 Adjacent Floor 0 0 0.00 Infiltration 0 0 0 0 0 Infiltration 0 0 0.00 Sub Total =_> 0 0 0 0 0 0 Sub Total =_> 0 0 0.00 Internal Loads Internal Loads Lights 1,605 401 2,007 16 1,605 18 Lights 0 0 0.00 People 2,289 0 2,289 18 1,089 12 People 0 0 0.00 Misc 3,000 0 3,000 24 3,000 33 Misc 0 0 0.00 Sub Total =_> 6,894 401 7,295 58 5,694 62 Sub Total =_> 0 0 0.00 Ceiling Load 122 -122 0 0 124 1 Ceiling Load -39 0 0.00 Ventilation Load 0 0 1,089 9 0 0 Ventilation Load 0 -4,198 97.35 Adj Air Trans Heat 0 0 0 0 0 Adj Air Trans Heat 0 0 0 Dehumid. Ov Sizing 0 0 Ov/Undr Sizing 0 0 0.00 Ov/Undr Sizing 3,309 3,309 27 3,309 36 Exhaust Heat 19 -0.44 Exhaust Heat -60 -60 0 OA Preheat Diff. 0 0.00 Sup. Fan Heat 846 7 RA Preheat Diff. 0 0.00 Ret. Fan Heat 0 0 0 Additional Reheat 0 0.00 Duct Heat Pkup 0 0 0 System Plenum Heat -133 3.09 Underflr Sup Ht Pkup 0 0 Underflr Sup Ht Pkup 0 0.00 Supply Air Leakage 0 0 0 Supply Air Leakage 0 0.00 Grand Total ==> 10,325 220 12,479 100.00 9,127 100.00 Grand Total ==> -39 -4,313 100.00 Total 1.0 12.5 Project Name: BECU Dataset Name: GTWYBECU.TRC Leave DB/WB/HR 'F of gr/Ib 53.8 51.7 53.5 0.0 0.0 0.0 0.0 0.0 0.0 COOLING COIL SELECTION Cooling Total Capacity Sens Cap. Coil Airflow Enter DB/WB/HR ton MBh MBh cfm °F 'F gr/Ib Main CIg 1.0 12.5 10.8 408 77.4 62.3 59.4 Aux Clg 0.0 0.0 0.0 0 0.0 0.0 0.0 Opt Vent 0.0 0.0 0.0 0 0.0 0.0 0.0 Total 1.0 12.5 Project Name: BECU Dataset Name: GTWYBECU.TRC Leave DB/WB/HR 'F of gr/Ib 53.8 51.7 53.5 0.0 0.0 0.0 0.0 0.0 0.0 TEMPERATURES AREAS Cooling Cooling Heating Heating Gross Total Glass 70.1 Ra Plenum 75.7 ft' (%) Floor 588 Ret/OA 76.8 Part 0 0.2 0.0 Int Door 0 0.0 Fn Frict ExFlr 0 MinStop/Rh 0 Roof 0 0 0 Wall 0 0 0 Ext Door 0 0 0 TEMPERATURES HEATING COIL SELECTION Cooling Cooling Heating Heating SADB 55.0 70.1 Ra Plenum 75.7 69.8 Return 75.7 69.8 Ret/OA 76.8 60.6 Fn MtrTD 0.2 0.0 Fn BIdTD 0.4 0.0 Fn Frict 1.3 0.0 AIRFLOWS HEATING COIL SELECTION Cooling Cooling Heating Diffuser 408 408 Terminal 408 408 Main Fan 408 408 Sec Fan 0 0 Nom Vent 82 82 AHU Vent 82 82 Infil 0 0 MinStop/Rh 0 0 Return 408 408 Exhaust 82 82 Rm Exh 0 0 Auxiliary 0 0 Leakage Dwn 0 0 Leakage Ups 0 0 ENGINEERING CKS HEATING COIL SELECTION Cooling Heating % OA 20.0 20.0 cfm/ft' 0.69 0.69 cfm/ton 392.33 -4.3 408 Wilton 565.41 Aux Htg Btu/heft' 21.22 -7.33 No. People 6.0 10.2/1000 ft' TRACE® 700 v6.3.2 calculated at 10:11 AM on 04/08/2016 Alternative - 1 System Checksums Report Page 4 of 16 HEATING COIL SELECTION Capacity Coil Airflow Ent Lvg MBh cfm °F 'F Main Htg -4.3 408 60.6 70.1 Aux Htg 0.0 0 0.0 0.0 Preheat 0.0 0 0.0 0.0 Humidif 0.0 0 0.0 0.0 Opt Vent 0.0 0 0.0 0.0 Total -4.3 TRACE® 700 v6.3.2 calculated at 10:11 AM on 04/08/2016 Alternative - 1 System Checksums Report Page 4 of 16 Room Checksums By MACDONALD-MILLER 203a Open Office Project Name: BECU Dataset Name: GTWYBECU.TRC COOLING COIL PEAK Cooling COOLING COIL SELECTION CLG SPACE PEAK Gross Total HEATING COIL PEAK Ra Plenum Peaked at Time: Mo/Hr: 7 / 16 Enter DB/WB/HR Mo/Hr. 8 / 16 ton Mo/Hr: Heating Design cfm Outside Air: OADB/WB/HR: 81 / 65 / 66 Main Clg OADB: 81 25.8 OADB: 24 58.7 53.8 51.6 Space Plenum Net Percent Space Percent 0.0 0.0 Space Peak Coil Peak Percent Opt Vent Sens. + Lat. Sens. + Lat Total Of Total Sensible Of Total 0.0 0.0 Space Sens Tot Sens Of Total 29.5 Btu/h Btu/h Btu/h (%) Btu/h (%) Btu/h Btu/h (/) Envelope Loads Envelope Loads Skylite Solar 0 0 0 0 0 0 Skylite Solar 0 0 0.00 Skylite Cond 0 0 0 0 0 0 Skylite Cond 0 0 0.00 Roof Cond 0 0 0 0 0 0 Roof Cond 0 0 0.00 Glass Solar 0 0 0 0 0 0 Glass Solar 0 0 0.00 Glass/Door Cond 0 0 0 0 0 0 Glass/Door Cond 0 0 0.00 Wall Cond 0 0 0 0 0 0 Wall Cond 0 0 0.00 Partition/Door 0 0 0 0 0 Partition/Door 0 0 0.00 Floor 0 0 0 0 0 Floor 0 0 0.00 Adjacent Floor 0 0 0 0 0 0 Adjacent Floor 0 0 0.00 Infiltration 0 0 0 0 0 Infiltration 0 0 0.00 Sub Total =_> 0 0 0 0 0 0 Sub Total ==> 0 0 0.00 Internal Loads Internal Loads Lights 4,352 1,088 5,440 18 4,352 20 Lights 0 0 0.00 People 4,577 0 4,577 16 2,177 10 People 0 0 0.00 Misc 6,000 0 6,000 20 6,000 28 Misc 0 0 0.00 Sub Total ==> 14,929 1,088 16,017 54 12,529 58 Sub Total ==> 0 0 0.00 Ceiling Load 331 -331 0 0 337 2 Ceiling Load -105 0 0.00 Ventilation Load 0 0 2,715 9 0 0 Ventilation Load 0 -10,010 97.23 Adj Air Trans Heat 0 0 0 0 0 Adj Air Trans Heat 0 0 0 Dehumid. Ov Sizing 0 0 Ov/Undr Sizing 0 0 0.00 Ov/Undr Sizing 8,894 8,894 30 8,894 41 Exhaust Heat 45 -0.44 Exhaust Heat -143 -143 0 OA Preheat Diff. 0 0.00 Sup. Fan Heat 2,018 7 RA Preheat Diff. 0 0.00 Ret. Fan Heat 0 0 0 Additional Reheat 0 0.00 Duct Heat Pkup 0 0 0 System Plenum Heat -330 3.21 Underflr Sup Ht Pkup 0 0 Underflr Sup Ht Pkup 0 0.00 Supply Air Leakage 0 0 0 Supply Air Leakage 0 0.00 Grand Total ==> 24,154 615 29,502 100.00 21,761 100.00 Grand Total ==> -105 -10,295 100.00 Project Name: BECU Dataset Name: GTWYBECU.TRC AREAS Cooling COOLING COIL SELECTION SADB Gross Total Glass Ra Plenum Total Capacity Sens Cap. Coil Airflow Enter DB/WB/HR Leave DB/WB/HR 1,594 ton MBh MBh cfm 'F 'F gr/Ib 'F 'F gr/Ib Main Clg 2.5 29.5 25.8 973 77.4 62.1 58.7 53.8 51.6 53.2 Aux Clg 0.0 0.0 0.0 0 0.0 0.0 0.0 0.0 0.0 0.0 Opt Vent 0.0 0.0 0.0 0 0.0 0.0 0.0 0.0 0.0 0.0 Total 2.5 29.5 Project Name: BECU Dataset Name: GTWYBECU.TRC TEMPERATURES AREAS Cooling Heating SADB Gross Total Glass Ra Plenum 75.7 69.8 ft' (%) Floor 1,594 76.8 60.6 Part 0 0.0 Fn 13IdTD Int Door 0 Fn Frict 1.3 ExFlr 0 MinStop/Rh 0 Roof 0 0 0 Wall 0 0 0 Ext Door 0 0 0 TEMPERATURES HEATING COIL SELECTION Cooling Heating SADB 55.0 70.1 Ra Plenum 75.7 69.8 Return 75.7 69.8 Ret/OA 76.8 60.6 Fn MtrTD 0.2 0.0 Fn 13IdTD 0.4 0.0 Fn Frict 1.3 0.0 AIRFLOWS HEATING COIL SELECTION Cooling Cooling Heating Diffuser 973 973 Terminal 973 973 Main Fan 973 973 Sec Fan 0 0 Nom Vent 195 195 AHU Vent 195 195 Infil 0 0 MinStop/Rh 0 0 Return 973 973 Exhaust 195 195 Rm Exh 0 0 Auxiliary 0 0 Leakage Dwn 0 0 Leakage Ups 0 0 ENGINEERING CKS HEATING COIL SELECTION Cooling Heating % OA 20.0 20.0 cfm/ft, 0.61 0.61 cfm/ton 395.67 -10.3 973 ft'/ton 648.37 Aux Htg Btu/hr-ft' 18.51 -6.46 No. People 12.0 7.5/1000 ft' TRACE® 700 v6.3.2 calculated at 10:11 AM on 04/08/2016 Alternative - 1 System Checksums Report Page 5 of 16 HEATING COIL SELECTION Capacity Coil Airflow Ent Lvg MBh cfm °F 'F Main Htg -10.3 973 60.6 70.1 Aux Htg 0.0 0 0.0 0.0 Preheat 0.0 0 0.0 0.0 Humidif 0.0 0 0.0 0.0 Opt Vent 0.0 0 0.0 0.0'. Total -10.3 TRACE® 700 v6.3.2 calculated at 10:11 AM on 04/08/2016 Alternative - 1 System Checksums Report Page 5 of 16 Room Checksums By MACDONALD-MILLER 203b Open Office Perim COOLING COIL PEAK AREAS Cooling CLG SPACE PEAK SADB HEATING COIL PEAK Glass Peaked at Time: Mo/Hr: 8/17 Mo/Hr: 9/16 Mo/Hr: Heating Design cfm Outside Air: OADB/WB/HR: 80 / 64 / 65 gr/Ib OADB: 76 34.1 OADB: 24 76.8 61.2 55.6 Space Plenum Net Percent Space Percent 0 Space Peak Coil Peak Percent 0.0 Sens. + Lat. Sens. + Lat Total Of Total Sensible Of Total 0.0 Space Sens Tot Sens Of Total 2.8 Btu/h Btu/h Btu/h I%) Btu/h I%) Btu/h Btu/h (%) Envelope Loads Envelope Loads Skylite Solar 0 0 0 0 0 0 Skylite Solar 0 0 0.00 Skylite Cond 0 0 0 0 0 0 Skylite Cond 0 0 0.00 Roof Cond 0 0 0 0 0 0 Roof Cond 0 0 0.00 Glass Solar 14,810 0 14,810 43 15,778 59 Glass Solar 0 0 0.00 Glass/Door Cond 353 0 353 1 -45 0 Glass/Door Cond -4,470 -4,470 23.71 Wall Cond 1,739 959 2,698 8 1,592 6 Wall Cond -1,418 -2,206 11.70 Partition/Door 0 0 0 0 0 Partition/Door 0 0 0.00 Floor 0 0 0 0 0 Floor 0 0 0.00 Adjacent Floor 0 0 0 0 0 0 Adjacent Floor 0 0 0.00 Infiltration 671 671 2 66 0 Infiltration -2,624 -2,624 13.92 Sub Total =_> 17,573 959 18,533 54 17,392 65 Sub Total =_> -8,512 -9,300 49.33 Internal Loads Internal Loads Lights 3,061 765 3,826 11 3,061 11 Lights 0 0 0.00 People 3,047 0 3,047 9 1,623 6 People 0 0 0.00 Misc 4,500 0 4,500 13 4,500 17 Misc -2,803 -2,803 14.86 Sub Total =_> 10,608 765 11,373 33 9,184 34 Sub Total =_> -2,803 -2,803 14.86 Ceiling Load 242 -242 0 0 234 1 Ceiling Load -74 0 0.00 Ventilation Load 0 0 1,846 5 0 0 Ventilation Load 0 -7,220 38.30 Adj Air Trans Heat 0 0 0 0 0 Adj Air Trans Heat 0 0 0 Dehumid. Ov Sizing 0 0 Ov/Undr Sizing 0 0 0.00 Ov/Undr Sizing 21 21 0 21 0 Exhaust Heat 44 -0.24 Exhaust Heat -146 -146 0 OA Preheat Diff. 0 0.00 Sup. Fan Heat 2,488 7 RA Preheat Diff. 0 0.00 Ret. Fan Heat 0 0 0 Additional Reheat 0 0.00 Duct Heat Pkup 0 0 0 System Plenum Heat 424 -2.25 Underflr Sup Ht Pkup 0 0 Underflr Sup Ht Pkup 0 0.00 Supply Air Leakage 0 0 0 Supply Air Leakage 0 0.00 Grand Total ==> 28,445 1,336 34,115 100.00 26,830 100.00 Grand Total ==> -11,388 -18,853 100.00 Project Name: BECU Dataset Name: GTWYBECU.TRC AREAS Cooling COOLING COIL SELECTION SADB Gross Total Glass Ra Plenum Total Capacity Sens Cap. Coil Airflow Enter DB/WB/HR Leave DB/WB/HR 1,121 ton MBh MBh cfm 'F 'F gr/Ib 'F 'F gr/Ib Main Clg 2.8 34.1 31.1 1,199 76.8 61.2 55.6 53.8 51.1 51.6 Aux Clg 0.0 0.0 0.0 0 0.0 0.0 0.0 0.0 0.0 0.0 Opt Vent 0.0 0.0 0.0 0 0.0 0.0 0.0 0.0 0.0 0.0 Total 2.8 34.1 Project Name: BECU Dataset Name: GTWYBECU.TRC TEMPERATURES AREAS Cooling Heating SADB Gross Total Glass Ra Plenum 75.7 69.8 ft' (/,) Floor 1,121 76.2 64.4 Part 0 0.0 Fn BIdTD Int Door 0 Fn Frict 1.3 ExFlr 0 MinStop/Rh 0 Roof 0 0 0 Wall 988 238 24 Ext Door 0 0 0 TEMPERATURES HEATING COIL SELECTION Cooling Heating SADB 55.0 78.5 Ra Plenum 75.7 69.8 Return 75.7 69.8 Ret/OA 76.2 64.4 Fn MtrTD 0.2 0.0 Fn BIdTD 0.4 0.0 Fn Frict 1.3 0.0 AIRFLOWS HEATING COIL SELECTION Cooling Cooling Heating Diffuser 1,199 1,199 Terminal 1,199 1,199 Main Fan 1,199 1,199 Sec Fan 0 0 Nom Vent 140 140 AHU Vent 140 140 Infil 51 51 MinStop/Rh 0 0 Return 1,250 1,250 Exhaust 191 191 Rm Exh 0 0 Auxiliary 0 0 Leakage Dwn 0 0 Leakage Ups 0 0 ENGINEERING CKS HEATING COIL SELECTION Cooling Heating OA 11.7 11.7 cfm/ft' 1.07 1.07 cfm/ton 421.88 -18.9 1,199 ft'/ton 394.32 Htg Btu/heft' 30.43 -16.82 No. People 9.0 8.0/1000 ft2 TRACE® 700 v6.3.2 calculated at 10:11 AM on 04/08/2016 Alternative - 1 System Checksums Report Page 6 of 16 HEATING COIL SELECTION Capacity Coil Airflow Ent Lvg MBh cfm 'F 'F i Htg -18.9 1,199 64.4 78.5 Htg 0.0 0 0.0 0.0' seat 0.0 0 0.0 0.0, iidif 0.0 0 0.0 0.0 Vent 0.0 0 0.0 0.0 1/ -18.9 TRACE® 700 v6.3.2 calculated at 10:11 AM on 04/08/2016 Alternative - 1 System Checksums Report Page 6 of 16 Room Checksums By MACDONALD-MILLER 203c Open Office Perim COOLING COIL PEAK AREAS CLG SPACE PEAK Capacity Coil Airflow HEATING COIL PEAK Glass TEMPERATURES Total Capacity Peaked at Time: Mo/Hr: 8 / 13 916 Mo/Hr: 9 / 12 MBh Mo/Hr: Heating Design gr/Ib 'F 'F Cooling Heating Outside Air: OADB/WB/HR: 80 / 65 / 68 OADB: 73 53.8 51.2 OADB: 24 0.0 SADB 55.0 79.2 0.0 0.0 0.0 0.0 0.0 0.0 Opt Vent 0.0 0.0 0.0 0 0.0 0.0 0.0 Ra Plenum 75.6 69.8 2.1 Space Plenum Net Percent Space Percent Space Peak Coil Peak Percent Return 75.6 69.8 Sens. + Lat. Sens. + Lat Total Of Total Sensible Of Total Space Sens Tot Sens Of Total Ret/OA 76.1 64.0 Btu/h Btu/h Btu/h (%) Btu/h (%) Btu/h Btu/h (%) Fn MtrTD 0.2 0.0 Envelope Loads P Envelope Loads Fn BIdTD 0.4 0.0 Skylite Solar 0 0 0 0 0 0 Skylite Solar 0 0 0.00 Fn Frict 1.3 0.0 Skylite Cond 0 0 0 0 0 0 Skylite Cond 0 0 0.00 Roof Cond 0 0 0 0 0 0 Roof Cond 0 0 0.00 Glass Solar 10,644 0 10,644 42 12,013 60 Glass Solar 0 0 0.00 AIRFLOWS Glass/Door Cond 168 0 168 1 -336 -2 Glass/Door Cond -3,574 -3,574 23.62 Wall Cond 1,198 668 1,866 7 1,071 5 Wall Cond -1,100 -1,717 11.35 Cooling Heating Partition/Door 0 0 0 0 0 Partition/Door 0 0 0.00 Diffuser 888 888 Floor 0 0 0 0 0 Floor 0 0 0.00 Terminal 888 888 Adjacent Floor 0 0 0 0 0 0 Adjacent Floor 0 0 0.00 Main Fan 888 888 Infiltration 603 603 2 -107 -1 Infiltration -2,144 -2,144 14.17 Sec Fan 0 0 Sub Total =_> 12,612 668 13,280 52 12,642 64 Sub Total =_> -6,818 -7,435 49.13 Nom Vent 112 112 AHU Vent 112 112 Internal Loads Internal Loads Infil 42 42 Lights 2,501 625 3,126 12 2,501 13 Lights 0 0 0.00 MinStop/Rh 0 0 People 2,292 0 2,292 9 1,041 5 People 0 0 0.00 Return 929 929 Misc 3,500 0 3,500 14 3,500 18 Misc -2,290 -2,290 15.13 Exhaust 154 154 Sub Total =_> 8,293 625 8,918 35 7,042 35 Sub Total =_> -2,290 -2,290 15.13 Rm Exh 0 0 Auxiliary 0 0 Ceiling Load 173 -173 0 0 159 1 Ceiling Load -60 0 0.00 Leakage Dwn 0 0 Ventilation Load 0 0 1,627 6 0 0 Ventilation Load 0 -5,786 38.23 Leakage Ups 0 0 Adj Air Trans Heat 0 0 0 0 0 Adj Air Trans Heat 0 0 0 Dehumid. Ov Sizing 0 0 Ov/Undr Sizing 0 0 0.00 Ov/Undr Sizing 14 14 0 14 0 Exhaust Heat 36 -0.24 ENGINEERING CKS Exhaust Heat -103 -103 0 OA Preheat Diff. 0 0.00 Sup. Fan Heat 1,841 7 RA Preheat Diff. 0 0.00 Cooling Heating Ret. Fan Heat 0 0 0 Additional Reheat 0 0.00 % OA 12.7 12.7 Duct Heat Pkup 0 0 0 System Plenum Heat 342 -2.26 cfm/ft' 0.97 0.97 Underflr Sup Ht Pkup 0 0 Underflr Sup Ht Pkup 0 0.00 cfm/ton 416.43 Supply Air Leakage 0 0 0 Supply Air Leakage 0 0.00 ft'/ton 429.74 Btu/hr-ft' 27.92 -16.52 Grand Total ==> 21,093 1,017 25,578 100.00 19,857 100.00 Grand Total ==> -9,168 -15,134 100.00 No. People 7.0 7.6/1000 ft' Project Name: BECU Dataset Name: GTWYBECU.TRC AREAS COOLING COIL SELECTION Capacity Coil Airflow Gross Total Glass Total Capacity Sens Cap. Coil Airflow Enter DB/WB/HR Leave DB/WB/HR 916 ton MBh MBh cfm 'F 'F gr/Ib 'F 'F gr/Ib Main Clg 2.1 25.6 22.9 888 76.7 61.4 56.4 53.8 51.2 51.9 Aux Clg 0.0 0.0 0.0 0 0.0 0.0 0.0 0.0 0.0 0.0 Opt Vent 0.0 0.0 0.0 0 0.0 0.0 0.0 0.0 0.0 0.0 Total 2.1 25.6 Project Name: BECU Dataset Name: GTWYBECU.TRC TRACE® 700 v6.3.2 calculated at 10:11 AM on 04/08/2016 Alternative - 1 System Checksums Report Page 7 of 16 AREAS Capacity Coil Airflow Gross Total Glass MBh cfm 'F ft' (%) Floor 916 79.2 Aux Htg Part 0 0.0 Preheat Int Door 0 0.0 Humidif ExFlr 0 0.0 Opt Vent Roof 0 0 0 Wall 774 190 25 Ext Door 0 0 0 TRACE® 700 v6.3.2 calculated at 10:11 AM on 04/08/2016 Alternative - 1 System Checksums Report Page 7 of 16 HEATING COIL SELECTION Capacity Coil Airflow Ent Lvg MBh cfm 'F °F Main Htg -15.1 888 64.0 79.2 Aux Htg 0.0 0 0.0 0.0 Preheat 0.0 0 0.0 0.0 Humidif 0.0 0 0.0 0.0 Opt Vent 0.0 0 0.0 0.0 Total -15.1 TRACE® 700 v6.3.2 calculated at 10:11 AM on 04/08/2016 Alternative - 1 System Checksums Report Page 7 of 16 Room Checksums By MACDONALD-MILLER 203d Open Office Total 7.0 84.1 Project Name: BECU Dataset Name: GTWYBECU.TRC Leave DB/WB/HR 'F 'F gr/Ib 53.8 51.7 53.7 0.0 0.0 0.0 0.0 0.0 0.0 COOLING COIL PEAK Cooling Total Capacity CLG SPACE PEAK Coil Airflow HEATING COIL PEAK ton MBh Peaked at Time: Mo/Hr: 7/16 Mo/Hr: 8 / 16 77.4 62.3 Mo/Hr: Heating Design 0.0 Outside Air: OADB/WB/HR: 81 / 65 / 66 OADB: 81 0.0 0.0 OADB: 24 Roof 0 Space Plenum Net Percent Space Percent Ext Door Space Peak Coil Peak Percent 0 Sens. + Lat. Sens. + Lat Total Of Total Sensible Of Total Space Sens Tot Sens Of Total Btu/h Btu/h Btu/h (%) Btu/h (%) Btu/h Btu/h Envelope Loads Envelope Loads Skylite Solar 0 0 0 0 0 0 Skylite Solar 0 0 0.00 Skylite Cond 0 0 0 0 0 0 Skylite Cond 0 0 0.00 Roof Cond 0 0 0 0 0 0 Roof Cond 0 0 0.00 Glass Solar 0 0 0 0 0 0 Glass Solar 0 0 0.00 Glass/Door Cond 0 0 0 0 0 0 Glass/Door Cond 0 0 0.00 Wall Cond 0 0 0 0 0 0 Wall Cond 0 0 0.00 Partition/Door 0 0 0 0 0 Partition/Door 0 0 0.00 Floor 0 0 0 0 0 Floor 0 0 0.00 Adjacent Floor 0 0 0 0 0 0 Adjacent Floor 0 0 0.00 Infiltration 0 0 0 0 0 Infiltration 0 0 0.00 Sub Total =_> 0 0 0 0 0 0 Sub Total =_> 0 0 0.00 Internal Loads Internal Loads Lights 10,173 2,543 12,717 15 10,173 17 Lights 0 0 0.00 People 16,401 0 16,401 19 7,801 13 People 0 0 0.00 Misc 23,500 0 23,500 28 23,500 38 Misc 0 0 0.00 Sub Total =_> 50,075 2,543 52,618 63 41,475 68 Sub Total =_> 0 0 0.00 Ceiling Load 773 -773 0 0 789 1 Ceiling Load -245 0 0.00 Ventilation Load 0 0 7,177 9 0 0 Ventilation Load 0 -28,206 97.40 Adj Air Trans Heat 0 0 0 0 0 Adj Air Trans Heat 0 0 0 Dehumid. Ov Sizing 0 0 Ov/Undr Sizing 0 0 0.00 Ov/Undr Sizing 19,054 19,054 23 19,054 31 Exhaust Heat 127 -0.44 Exhaust Heat -402 -402 0 OA Preheat Diff. 0 0.00 Sup. Fan Heat 5,685 7 RA Preheat Diff. 0 0.00 Ret. Fan Heat 0 0 0 Additional Reheat 0 0.00 Duct Heat Pkup 0 0 0 System Plenum Heat -881 3.04 Underflr Sup Ht Pkup 0 0 Underflr Sup Ht Pkup 0 0.00 Supply Air Leakage 0 0 0 Supply Air Leakage 0 0.00 Grand Total ==> 69,902 1,368 84,132 100.00 61,317 100.00 Grand Total==> -245 -28,960 100.00 Total 7.0 84.1 Project Name: BECU Dataset Name: GTWYBECU.TRC Leave DB/WB/HR 'F 'F gr/Ib 53.8 51.7 53.7 0.0 0.0 0.0 0.0 0.0 0.0 COOLING COIL SELECTION Cooling Total Capacity Sens Cap. Coil Airflow Enter DB/WB/HR ton MBh MBh cfm 'F 'F gr/Ib Main Clg 7.0 84.1 72.3 2,741 77.4 62.3 59.7 Aux Clg 0.0 0.0 0.0 0 0.0 0.0 0.0 Opt Vent 0.0 0.0 0.0 0 0.0 0.0 0.0 Total 7.0 84.1 Project Name: BECU Dataset Name: GTWYBECU.TRC Leave DB/WB/HR 'F 'F gr/Ib 53.8 51.7 53.7 0.0 0.0 0.0 0.0 0.0 0.0 TEMPERATURES AREAS Cooling - SADB Gross Total Glass Ra Plenum 75.7 69.8 ft' I%) Floor 3,726 76.8 60.6 Part 0 0.0 Fn BIdTD Int Door 0 Fn Frict 1.3 ExFlr 0 MinStop/Rh 0 Roof 0 0 0 Wall 0 0 0 Ext Door 0 0 0 TEMPERATURES HEATING COIL SELECTION Cooling Heating SADB 55.0 70.1 Ra Plenum 75.7 69.8 Return 75.7 69.8 Ret/OA 76.8 60.6 Fn MtrTD 0.2 0.0 Fn BIdTD 0.4 0.0 Fn Frict 1.3 0.0 AIRFLOWS HEATING COIL SELECTION Cooling Cooling Heating Diffuser 2,741 2,741 Terminal 2,741 2,741 Main Fan 2,741 2,741 Sec Fan 0 0 Nom Vent 548 548 AHU Vent 548 548 Infil 0 0 MinStop/Rh 0 0 Return 2,741 2,741 Exhaust 548 548 Rm Exh 0 0 Auxiliary 0 0 Leakage Dwn 0 0 Leakage Ups 0 0 ENGINEERING CKS HEATING COIL SELECTION Cooling Heating OA 20.0 20.0 cfm/ft' 0.74 0.74 cfm/ton 390.95 -29.0 2,741 ft'/ton 531.45 Aux Htg Btu/heft' 22.58 -7.77 No. People 43.0 11.5/1000 ft' TRACE& 700 v6.3.2 calculated at 10:11 AM on 04/08/2016 Alternative - 1 System Checksums Report Page 8 of 16 HEATING COIL SELECTION Capacity Coil Airflow Ent Lvg MBh cfm 'F 'F Main Htg -29.0 2,741 60.6 70.1 Aux Htg 0.0 0 0.0 0.0 Preheat 0.0 0 0.0 0.0 Humidif 0.0 0 0.0 0.0 Opt Vent 0.0 0 0.0 0.0 Total -29.0 TRACE& 700 v6.3.2 calculated at 10:11 AM on 04/08/2016 Alternative - 1 System Checksums Report Page 8 of 16 Room Checksums By MACDONALD-MILLER 205 Break Room COOLING COIL PEAK COOLING COIL SELECTION CLG SPACE PEAK Sens Cap. HEATING COIL PEAK Enter DB/WB/HR TEMPERATURES Peaked at Time: Mo/Hr: 7/16 Mo/Hr: 8/16 Mo/Hr: Heating Design 0.0 0 Cooling Heating Outside Air: OADB/WB/HR: 81 / 65 / 66 OADB: 81 Vent OADB: 24 0 SADB 55.0 70.0 0 0 Ext Door 0 0 0 Ra Plenum 75.7 69.8 Space Plenum Net Percent Space Percent Space Peak Coil Peak Percent Return 75.7 69.8 Sens. + Lat. Sens. + Lat Total Of Total Sensible Of Total Space Sens Tot Sens Of Total Ret/OA 76.8 60.6 Btu/h Btu/h Btu/h (%) Btu/h (%) Btu/h Btu/h (%) Fn MtrTD 0.2 0.0 Envelope Loads Envelope Loads Fn BIdTD 0.4 0.0 Skylite Solar 0 0 0 0 0 0 Skylite Solar 0 0 0.00 Fn Frict 1.3 0.0 Skylite Cond 0 0 0 0 0 0 Skylite Cond 0 0 0.00 Roof Cond 0 0 0 0 0 0 Roof Cond 0 0 0.00 Glass Solar 0 0 0 0 0 0 Glass Solar 0 0 0.00 AIRFLOWS Glass/Door Cond 0 0 0 0 0 0 Glass/Door Cond 0 0 0.00 Cooling Heating Wall Cond 0 0 0 0 0 0 Wall Cond 0 0 0.00 Partition/Door 0 0 0 0 0 Partition/Door 0 0 0.00 Diffuser 805 805 Floor 0 0 0 0 0 Floor 0 0 0.00 Terminal 805 805 Adjacent Floor 0 0 0 0 0 0 Adjacent Floor 0 0 0.00 Main Fan 805 805 Infiltration 0 0 0 0 0 Infiltration 0 0 0.00 Sec Fan 0 0 Sub Total =_> 0 0 0 0 0 0 Sub Total =_> 0 0 0.00 Nom Vent 161 161 AHU Vent 161 161 Internal Loads Internal Loads Infil 0 0 Lights 1,308 327 1,635 6 1,308 7 Lights 0 0 0.00 MinStop/Rh 0 0 People 7,629 0 7,629 30 3,629 20 People 0 0 0.00 Return 805 805 Misc 3,000 0 3,000 12 3,000 17 Misc 0 0 0.00 Exhaust 161 161 Sub Total =_> 11,936 327 12,263 48 7,936 44 Sub Total =_> 0 0 0.00 Rm Exh 0 0 Auxiliary 0 0 Ceiling Load 99 -99 0 0 101 1 Ceiling Load -31 0 0.00 Leakage Dwn 0 0 Ventilation Load 0 0 1,729 7 0 0 Ventilation Load 0 -8,280 97.86 Leakage Ups 0 0 Adj Air Trans Heat 0 0 0 0 0 Adj Air Trans Heat 0 0 0 Dehumid. Ov Sizing 0 0 Ov/Undr Sizing 0 0 0.00 Ov/Undr Sizing 9,962 9,962 39 9,962 55 Exhaust Heat 37 -0.44 ENGINEERING CKS Exhaust Heat -118 -118 0 OA Preheat Diff. 0 0.00 Sup. Fan Heat 1,669 7 RA Preheat Diff. 0 0.00 Cooling Heating Ret. Fan Heat 0 0 0 Additional Reheat 0 0.00 % OA 20.0 20.0 Duct Heat Pkup 0 0 0 System Plenum Heat -218 2.58 cfm/ft' 1.68 1.68 Underflr Sup Ht Pkup 0 0 Underflr Sup Ht Pkup 0 0.00 cfm/ton 378.57 Supply Air Leakage 0 0 0 Supply Air Leakage 0 0.00 ft'/ton 225.37 Btu/heft' 53.25 -17.66 Grand Total ==> 21,998 110 25,505 100.00 18,000 100.00 Grand Total ==> -31 -8,461 100.00 No. People 20.0 41.8/1000 ft' Total 2.1 25.5 Project Name: BECU Dataset Name: GTWYBECU.TRC Leave DB/WB/HR 'F 'F gr/Ib 53.8 52.0 54.9 0.0 0.0 0.0 0.0 0.0 0.0 COOLING COIL SELECTION Total Capacity Sens Cap. Coil Airflow Enter DB/WB/HR ton MBh MBh cfm °F °F gr/Ib Main Clg 2.1 25.5 20.9 805 77.4 62.9 62.4 Aux Clg 0.0 0.0 0.0 0 0.0 0.0 0.0 Opt Vent 0.0 0.0 0.0 0 0.0 0.0 0.0 Total 2.1 25.5 Project Name: BECU Dataset Name: GTWYBECU.TRC Leave DB/WB/HR 'F 'F gr/Ib 53.8 52.0 54.9 0.0 0.0 0.0 0.0 0.0 0.0 TRACE® 700 v6.3.2 calculated at 10:11 AM on 04/08/2016 Alternative - 1 System Checksums Report Page 9 of 16 AREAS Capacity Coil Airflow Gross Total Glass MBh cfm °F ft' (%) Floor 479 70.0 c Htg Part 0 0.0 heat Int Door 0 0.0 nidif ExFlr 0 0.0 Vent Roof 0 0 0 Wall 0 0 0 Ext Door 0 0 0 TRACE® 700 v6.3.2 calculated at 10:11 AM on 04/08/2016 Alternative - 1 System Checksums Report Page 9 of 16 HEATING COIL SELECTION Capacity Coil Airflow Ent Lvg MBh cfm °F °F n Htg -8.5 805 60.6 70.0 c Htg 0.0 0 0.0 0.0 heat 0.0 0 0.0 0.0 nidif 0.0 0 0.0 0.0 Vent 0.0 0 0.0 0.0 a/ -8.5 TRACE® 700 v6.3.2 calculated at 10:11 AM on 04/08/2016 Alternative - 1 System Checksums Report Page 9 of 16 Room Checksums By MACDONALD-MILLER 210 Mothers Room COOLING COIL PEAK COOLING COIL SELECTION CLG SPACE PEAK Sens Cap. HEATING COIL PEAK ton MBh TEMPERATURES cfm °F °F Peaked at Time: Mo/Hr: 8 / 13 61.2 Mo/Hr: 8/13 Mo/Hr: Heating Design 0.0 0 0.0 0.0 Cooling Heating Outside Air: OADB/WB/HR: 80 / 65 / 68 OADB: 80 Roof OADB: 24 0 SADB 55.0 77.6 0 Ext Door 0 0 0 Ra Plenum 75.6 69.8 Space Plenum Net Percent Space Percent Space Peak Coil Peak Percent Return 75.6 69.8 Sens. + Lat. Sens. + Lat Total Of Total Sensible Of Total Space Sens Tot Sens Of Total RetlOA 76.4 60.6 Btu/h Btu/h Btu/h (%) Btu/h (%) Btu/h Btu/h (%) Fn MtrTD 0.2 0.0 Envelope Loads Envelope Loads Fn 13IdTD 0.4 0.0 Skylite Solar 0 0 0 0 0 0 Skylite Solar 0 0 0.00 Fn Frict 1.3 0.0 Skylite Cond 0 0 0 0 0 0 Skylite Cond 0 0 0.00 Roof Cond 0 0 0 0 0 0 Roof Cond 0 0 0.00 Glass Solar 0 0 0 0 0 0 Glass Solar 0 0 0.00 AIRFLOWS Glass/Door Cond Wall Cond 0 200 0 74 0 274 0 17 0 200 0 18 Glass/Door Cond Wall Cond 0 -186 0 -256 0.00 27.79 Cooling Heating Partition/Door 0 0 0 0 0 Partition/Door 0 0 0.00 Diffuser 49 49 Floor 0 0 0 0 0 Floor 0 0 0.00 Terminal 49 49 Adjacent Floor 0 0 0 0 0 0 Adjacent Floor 0 0 0.00 Main Fan 49 49 Infiltration 23 23 1 11 1 Infiltration -108 -108 11.70 Sec Fan 0 0 Sub Total =_> 223 74 297 19 211 19 Sub Total =_> -294 -363 39.50 Nom Vent 10 10 AHU Vent 10 10 Internal Loads Internal Loads Infil 2 2 Lights 126 31 157 10 126 12 Lights 0 0 0.00 MinStop/Rh 0 0 People 326 0 326 21 151 14 People 0 0 0.00 Return 51 51 Misc 0 0 0 0 0 0 Misc -115 -115 12.50 Exhaust 12 12 Sub Total =_> 452 31 483 31 277 26 Sub Total ==> -115 -115 12.50 Rm Exh 0 0 Auxiliary 0 0 Ceiling Load 9 -9 0 0 9 1 Ceiling Load -3 0 0.00 Leakage Dwn 0 0 Ventilation Load 0 0 108 7 0 0 Ventilation Load 0 -499 54.23 Leakage Ups 0 0 Adj Air Trans Heat 0 0 0 0 0 Adj Air Trans Heat 0 0 0 Dehumid. Ov Sizing 0 0 Ov/Undr Sizing 0 0 0.00 Ov/Undr Sizing 589 589 38 589 54 Exhaust Heat 3 -0.30 ENGINEERING CKS Exhaust Heat -8 -8 -1 OA Preheat Diff. 0 0.00 Sup. Fan Heat 101 6 RA Preheat Diff. 0 0.00 Cooling Heating Ret. Fan Heat 0 0 0 Additional Reheat 0 0.00 % OA 20.0 20.0 Duct Heat Pkup 0 0 0 System Plenum Heat 55 -5.93 cfm/ft' 1.05 1.05 Underflr Sup Ht Pkup 0 0 Underflr Sup Ht Pkup 0 0.00 cfm/ton 370.81 Supply Air Leakage 0 0 0 Supply Air Leakage 0 0.00 ft'/ton 351.70 Btu/heft' 34.12 -20.00 Grand Total ==> 1,272 89 1,570 100.00 1,085 100.00 Grand Total ==> -412 -920 100.00 No. People 1.0 21.7/1000 ft' Total 0.1 1.6 Project Name: BECU Dataset Name: GTWYBECU.TRC Leave DB/WB/HR °F °F gr/Ib 53.8 51.3 52.2 0.0 0.0 0.0 0.0 0.0 0.0 COOLING COIL SELECTION Total Capacity Sens Cap. Coil Airflow Enter DB/WB/HR ton MBh MBh cfm °F °F gr/Ib Main Clg 0.1 1.6 1.3 49 77.0 62.5 61.2 Aux Clg 0.0 0.0 0.0 0 0.0 0.0 0.0 Opt Vent 0.0 0.0 0.0 0 0.0 0.0 0.0 Total 0.1 1.6 Project Name: BECU Dataset Name: GTWYBECU.TRC Leave DB/WB/HR °F °F gr/Ib 53.8 51.3 52.2 0.0 0.0 0.0 0.0 0.0 0.0 TRACE® 700 v6.3.2 calculated at 10:11 AM on 04/08/2016 Alternative - 1 System Checksums Report Page 10 of 16 AREAS Capacity Coil Airflow Gross Total Glass MBh cfm °F ft' (�) Floor 46 77.6 \ux Htg Part 0 0.0 'reheat Int Door 0 0.0 iumidif ExFlr 0 0.0 )pt Vent Roof 0 0 0 Wall 87 0 0 Ext Door 0 0 0 TRACE® 700 v6.3.2 calculated at 10:11 AM on 04/08/2016 Alternative - 1 System Checksums Report Page 10 of 16 HEATING COIL SELECTION Capacity Coil Airflow Ent Lvg MBh cfm °F °F Aain Htg -0.9 49 60.6 77.6 \ux Htg 0.0 0 0.0 0.0 'reheat 0.0 0 0.0 0.0 iumidif 0.0 0 0.0 0.0 )pt Vent 0.0 0 0.0 0.0 otal -0.9 TRACE® 700 v6.3.2 calculated at 10:11 AM on 04/08/2016 Alternative - 1 System Checksums Report Page 10 of 16 Room Checksums By MACDONALD-MILLER 212 Conference Total 0.8 9.6 Project Name: BECU Dataset Name: GTWYBECU.TRC Leave DB/WB/HR °F °F gr/Ib 53.8 51.9 54.6 0.0 0.0 0.0 0.0 0.0 0.0 COOLING COIL PEAK Total Capacity CLG SPACE PEAK Enter DB/WB/HR HEATING COIL PEAK MBh cfm TEMPERATURES Peaked at Time: Mo/Hr: 8 / 16 77.1 62.3 Mo/Hr: 9 / 16 0.0 0 Mo/Hr: Heating Design Opt Vent 0.0 0.0 0.0 0 Cooling Heating Outside Air: OADB/WB/HR: 81 / 65 / 66 0 OADB: 76 Roof OADB: 24 0 SADB 55.0 75.7 31 Ext Door 0 0 0 Ra Plenum 75.7 69.8 Space Plenum Net Percent Space Percent Space Peak Coil Peak Percent Return 75.7 69.8 Sens. + Lat. Sens. + Lat Total Of Total Sensible Of Total Space Sens Tot Sens Of Total Ret/OA 76.5 62.5 Btu/h Btu/h Btu/h (%) Btu/h (%) Btu/h Btu/h (%) Fn MtrTD 0.2 0.0 Envelope Loads Envelope Loads Fn BIdTD 0.4 0.0 Skylite Solar 0 0 0 0 0 0 Skylite Solar 0 0 0.00 Fn Frict 1.3 0.0 Skylite Cond 0 0 0 0 0 0 Skylite Cond 0 0 0.00 Roof Cond 0 0 0 0 0 0 Roof Cond 0 0 0.00 Glass Solar 2,955 0 2,955 31 3,311 46 Glass Solar 0 0 0.00 AIRFLOWS Glass/Door Cond 86 0 86 1 -9 0 Glass/Door Cond -938 -938 19.95 Cooling Heating Wall Cond 221 141 362 4 228 3 Wall Cond -203 -333 7.09 Partition/Door 0 0 0 0 0 Partition/Door 0 0 0.00 Diffuser 320 320 Floor 0 0 0 0 0 Floor 0 0 0.00 Terminal 320 320 Adjacent Floor 0 0 0 0 0 0 Adjacent Floor 0 0 0.00 Main Fan 320 320 Infiltration 93 93 1 11 0 Infiltration -419 -419 8.91 Sec Fan 0 0 Sub Total =_> 3,356 141 3,496 36 3,540 49 Sub Total =_> -1,560 -1,690 35.95 Nom Vent 51 51 AHU Vent 51 51 Internal Loads Internal Loads Infil 8 8 Lights 489 122 611 6 489 7 Lights 0 0 0.00 MinStop/Rh 0 0 People 2,282 0 2,282 24 1,082 15 People 0 0 0.00 Return 328 328 Misc 2,000 0 2,000 21 2,000 28 Misc -448 -448 9.52 Exhaust 59 59 Sub Total =_> 4,771 122 4,893 51 3,571 50 Sub Total =_> -448 -448 9.52 Rm Exh 0 0 Auxiliary 0 0 Ceiling Load 38 -38 0 0 37 1 Ceiling Load -12 0 0.00 Leakage Dwn 0 0 Ventilation Load 0 0 583 6 0 0 Ventilation Load 0 -2,620 55.73 Leakage Ups 0 0 Adj Air Trans Heat 0 0 0 0 0 Adj Air Trans Heat 0 0 0 Dehumid. Ov Sizing 0 0 Ov/Undr Sizing 0 0 0.00 Ov/Undr Sizing 3 3 0 3 0 Exhaust Heat 14 -0.29 ENGINEERING CKS Exhaust Heat -44 -44 0 OA Preheat Diff. 0 0.00 Sup. Fan Heat 663 7 RA Preheat Diff. 0 0.00 Cooling Heating Ret. Fan Heat 0 0 0 Additional Reheat 0 0.00 % OA 15.9 15.9 Duct Heat Pkup 0 0 0 System Plenum Heat 42 -0.90 cfm/ft' 1.79 1.79 Underflr Sup Ht Pkup 0 0 Underflr Sup Ht Pkup 0 0.00 cfm/ton 399.83 Supply Air Leakage 0 0 0 Supply Air Leakage 0 0.00 ft'/ton 223.88 Btu/heft' 53.60 -26.27 Grand Total ==> 8,168 181 9,595 100.00 7,152 100.00 Grand Total ==> -2,019 -4,702 100.00 No. People 6.0 33.5/1000 ft' Total 0.8 9.6 Project Name: BECU Dataset Name: GTWYBECU.TRC Leave DB/WB/HR °F °F gr/Ib 53.8 51.9 54.6 0.0 0.0 0.0 0.0 0.0 0.0 COOLING COIL SELECTION Total Capacity Sens Cap. Coil Airflow Enter DB/WB/HR ton MBh MBh cfm °F °F gr/Ib Main Clg 0.8 9.6 8.1 320 77.1 62.3 60.2 Aux Cig 0.0 0.0 0.0 0 0.0 0.0 0.0 Opt Vent 0.0 0.0 0.0 0 0.0 0.0 0.0 Total 0.8 9.6 Project Name: BECU Dataset Name: GTWYBECU.TRC Leave DB/WB/HR °F °F gr/Ib 53.8 51.9 54.6 0.0 0.0 0.0 0.0 0.0 0.0 TRACE® 700 v6.3.2 calculated at 10:11 AM on 04/08/2016 Alternative - 1 System Checksums Report Page 11 of 16 AREAS Capacity Coil Airflow Gross Total Glass MBh cfm °F ft' (%) Floor 179 75.7 Aux Htg Part 0 0.0 Preheat Int Door 0 0.0 Humidif ExFlr 0 0.0 Opt Vent Roof 0 0 0 Wall 163 50 31 Ext Door 0 0 0 TRACE® 700 v6.3.2 calculated at 10:11 AM on 04/08/2016 Alternative - 1 System Checksums Report Page 11 of 16 HEATING COIL SELECTION Capacity Coil Airflow Ent Lvg MBh cfm °F °F Main Htg -4.7 320 62.5 75.7 Aux Htg 0.0 0 0.0 0.0 Preheat 0.0 0 0.0 0.0 Humidif 0.0 0 0.0 0.0 Opt Vent 0.0 0 0.0 0.0 Total -4.7 TRACE® 700 v6.3.2 calculated at 10:11 AM on 04/08/2016 Alternative - 1 System Checksums Report Page 11 of 16 Room Checksums By MACDONALD-MILLER 213 Office COOLING COIL PEAK COOLING COIL SELECTION CLG SPACE PEAK Sens Cap. Coil Airflow HEATING COIL PEAK ton MBh TEMPERATURES Peaked at Time: Mo/Hr: 9/16 Mo/Hr: 9 / 16 0.0 0 Mo/Hr: Heating Design Opt Vent 0.0 0.0 0.0 0 Cooling Heating Outside Air: OADB/WB/HR: 76 / 63 / 64 OADB: 76 Roof OADB: 24 0 SADB 55.0 78.1 34 Ext Door 0 0 0 Ra Plenum 75.7 69.8 Space Plenum Net Percent Space Percent Space Peak Coil Peak Percent Return 75.7 69.8 Sens. + Lat. Sens. + Lat Total Of Total Sensible Of Total Space Sens Tot Sens Of Total Ret/OA 75.7 65.8 Btu/h Btu/h Btu/h (%) Btu/h (%) Btu/h Btu/h (%) Fn MtrTD 0.2 0.0 Envelope Loads Envelope Loads Fn BIdTD 0.4 0.0 Skylite Solar 0 0 0 0 0 0 Skylite Solar 0 0 0.00 Fn Frict 1.3 0.0 Skylite Cond 0 0 0 0 0 0 Skylite Cond 0 0 0.00 Roof Cond 0 0 0 0 0 0 Roof Cond 0 0 0.00 Glass Solar 3,311 0 3,311 58 3,311 71 Glass Solar 0 0 0.00 AIRFLOWS Glass/Door Cond -9 0 -9 0 -9 0 Glass/Door Cond -938 -938 33.14 Cooling Heating Wall Cond 189 130 319 6 189 4 Wall Cond -168 -285 10.07 Partition/Door 0 0 0 0 0 Partition/Door 0 0 0.00 Diffuser 207 207 Floor 0 0 0 0 0 Floor 0 0 0.00 Terminal 207 207 Adjacent Floor 0 0 0 0 0 0 Adjacent Floor 0 0 0.00 Main Fan 207 207 Infiltration 64 64 1 9 0 Infiltration -363 -363 12.82 Sec Fan 0 0 Sub Total =_> 3,554 130 3,684 65 3,499 75 Sub Total ==> -1,469 -1,586 56.03 Nom Vent 18 18 AHU Vent 18 18 Internal Loads Internal Loads Infil 7 7 Lights 423 106 529 9 423 9 Lights 0 0 0.00 MinStop/Rh 0 0 People 380 0 380 7 180 4 People 0 0 0.00 Return 214 214 Misc 500 0 500 9 500 11 Misc -388 -388 13.69 Exhaust 25 25 Sub Total ==> 1,304 106 1,409 25 1,104 24 Sub Total ==> -388 -388 13.69 Rm Exh 0 0 Auxiliary 0 0 Ceiling Load 32 -32 0 0 32 1 Ceiling Load -10 0 0.00 Leakage Dwn 0 0 Ventilation Load 0 0 162 3 0 0 Ventilation Load 0 -920 32.50 Leakage Ups 0 0 Adj Air Trans Heat 0 0 0 0 0 Adj Air Trans Heat 0 0 0 Dehumid. Ov Sizing 0 0 Ov/Undr Sizing 0 0 0.00 Ov/Undr Sizing 3 3 0 3 0 Exhaust Heat 6 -0.20 ENGINEERING CKS Exhaust Heat -18 -18 0 OA Preheat Diff. 0 0.00 Sup. Fan Heat 430 8 RA Preheat Diff. 0 0.00 Cooling Heating Ret. Fan Heat 0 0 0 Additional Reheat 0 0.00 % OA 8.6 8.6 Duct Heat Pkup 0 0 0 System Plenum Heat 57 -2.02 cfm/ft' 1.34 1.34 Underflr Sup Ht Pkup 0 0 Underflr Sup Ht Pkup 0 0.00 cfm/ton 438.80 Supply Air Leakage 0 0 0 Supply Air Leakage 0 0.00 ft'/ton 328.07 Btu/heft' 36.58 -18.26 Grand Total ==> 4,892 186 5,670 100.00 4,638 100.00 Grand Total ==> -1,866 -2,830 100.00 No. People 1.0 6.5/1000 ft' Total 0.5 5.7 Leave DB/WB/HR 'F 'F gr/Ib 53.8 50.9 50.9 0.0 0.0 0.0 0.0 0.0 0.0 COOLING COIL SELECTION Total Capacity Sens Cap. Coil Airflow Enter DB/WB/HR ton MBh MBh cfm 'F 'F gr/Ib Main Clg 0.5 5.7 5.3 207 76.3 60.7 54.0 Aux Clg 0.0 0.0 0.0 0 0.0 0.0 0.0 Opt Vent 0.0 0.0 0.0 0 0.0 0.0 0.0 Total 0.5 5.7 Leave DB/WB/HR 'F 'F gr/Ib 53.8 50.9 50.9 0.0 0.0 0.0 0.0 0.0 0.0 Project Name: BECU TRACE@ 700 v6.3.2 calculated at 10:11 AM on 04/08/2016 Dataset Name: GTWYBECU.TRC Alternative - 1 System Checksums Report Page 12 of 16 AREAS Capacity Coil Airflow Gross Total Glass MBh cfm 'F ft' I%) Floor 155 78.1 K Htg Part 0 0.0 sheat Int Door 0 0.0 midif ExFlr 0 0.0 t Vent Roof 0 0 0 Wall 147 50 34 Ext Door 0 0 0 Project Name: BECU TRACE@ 700 v6.3.2 calculated at 10:11 AM on 04/08/2016 Dataset Name: GTWYBECU.TRC Alternative - 1 System Checksums Report Page 12 of 16 HEATING COIL SELECTION Capacity Coil Airflow Ent Lvg MBh cfm 'F 'F in Htg -2.8 207 65.8 78.1 K Htg 0.0 0 0.0 0.0 sheat 0.0 0 0.0 0.0 midif 0.0 0 0.0 0.0 t Vent 0.0 0 0.0 0.0 `al -2.8 Project Name: BECU TRACE@ 700 v6.3.2 calculated at 10:11 AM on 04/08/2016 Dataset Name: GTWYBECU.TRC Alternative - 1 System Checksums Report Page 12 of 16 Room Checksums By MACDONALD-MILLER 214 Office Total 0.5 5.7 Leave DB/WB/HR 'F °F gr/Ib 53.8 50.9 50.9 0.0 0.0 0.0 0.0 0.0 0.0 COOLING COIL PEAK Total Capacity CLG SPACE PEAK Coil Airflow Enter DB/WB/HR HEATING COIL PEAK MBh TEMPERATURES Peaked at Time: Mo/Hr: 9/16 Mo/Hr: 9/16 Mo/Hr: Heating Design 0.0 0 0.0 0.0 Cooling Heating Outside Air: OADB/WB/HR: 76 / 63 / 64 Opt Vent OADB: 76 0 OADB: 24 147 SADB 55.0 78.0 0 0 0 Ra Plenum 75.7 69.8 Space Plenum Net Percent Space Percent Space Peak Coil Peak Percent Return 75.7 69.8 Sens. + Lat. Sens. + Lat Total Of Total Sensible Of Total Space Sens Tot Sens Of Total Ret/OA 75.7 65.8 Btu/h Btu/h Btu/h (%) Btu/h (%) Btu/h Btu/h (%) Fn MtrTD 0.2 0.0 Envelope Loads Envelope Loads Fn BIdTD 0.4 0.0 Skylite Solar 0 0 0 0 0 0 Skylite Solar 0 0 0.00 Fn Frict 1.3 0.0 Skylite Cond 0 0 0 0 0 0 Skylite Cond 0 0 0.00 Roof Cond 0 0 0 0 0 0 Roof Cond 0 0 0.00 Glass Solar 3,323 0 3,323 58 3,323 71 Glass Solar 0 0 0.00 AIRFLOWS Glass/Door Cond -9 0 -9 0 -9 0 Glass/Door Cond -938 -938 33.04 Cooling Heating Wall Cond 189 131 319 6 189 4 Wall Cond -168 -285 10.04 Partition/Door 0 0 0 0 0 Partition/Door 0 0 0.00 Diffuser 208 208 Floor 0 0 0 0 0 Floor 0 0 0.00 Terminal 208 208 Adjacent Floor 0 0 0 0 0 0 Adjacent Floor 0 0 0.00 Main Fan 208 208 Infiltration 64 64 1 9 0 Infiltration -365 -365 12.87 Sec Fan 0 0 Sub Total =_> 3,566 131 3,697 65 3,511 75 Sub Total =_> -1,471 -1,588 55.94 Nom Vent 18 18 AHU Vent 18 18 Internal Loads Internal Loads Infil 7 7 Lights 426 106 532 9 426 9 Lights 0 0 0.00 MinStop/Rh 0 0 People 380 0 380 7 180 4 People 0 0 0.00 Return 215 215 Misc 500 0 500 9 500 11 Misc -390 -390 13.74 Exhaust 25 25 Sub Total =_> 1,306 106 1,413 25 1,106 24 Sub Total ==> -390 -390 13.74 Rm Exh 0 0 Auxiliary 0 0 Ceiling Load 33 -33 0 0 33 1 Ceiling Load -10 0 0.00 Leakage Dwn 0 0 Ventilation Load 0 0 162 3 0 0 Ventilation Load 0 -924 32.53 Leakage Ups 0 0 Adj Air Trans Heat 0 0 0 0 0 Adj Air Trans Heat 0 0 0 Dehumid. Ov Sizing 0 0 Ov/Undr Sizing 0 0 0.00 Ov/Undr Sizing 3 3 0 3 0 Exhaust Heat 6 -0.20 ENGINEERING CKS Exhaust Heat -18 -18 0 OA Preheat Diff. 0 0.00 Sup. Fan Heat 431 8 RA Preheat Diff. 0 0.00 Cooling Heating Ret. Fan Heat 0 0 0 Additional Reheat 0 0.00 % OA 8.6 8.6 Duct Heat Pkup 0 0 0 System Plenum Heat 57 -2.01 cfm/ft, 1.33 1.33 Underflr Sup Ht Pkup 0 0 Underflr Sup Ht Pkup 0 0.00 cfm/ton 438.83 Supply Air Leakage 0 0 0 Supply Air Leakage 0 0.00 ft'/ton 329.13 Btu/heft' 36.46 -18.20 Grand Total ==> 4,908 186 5,688 100.00 4,653 100.00 Grand Total ==> -1,871 -2,839 100.00 No. People 1.0 6.4/1000 ft' Total 0.5 5.7 Leave DB/WB/HR 'F °F gr/Ib 53.8 50.9 50.9 0.0 0.0 0.0 0.0 0.0 0.0 COOLING COIL SELECTION Total Capacity Sens Cap. Coil Airflow Enter DB/WB/HR ton MBh MBh cfm °F 'F gr/Ib Main Clg 0.5 5.7 5.3 208 76.3 60.7 54.0 Aux Clg 0.0 0.0 0.0 0 0.0 0.0 0.0 Opt Vent 0.0 0.0 0.0 0 0.0 0.0 0.0 Total 0.5 5.7 Leave DB/WB/HR 'F °F gr/Ib 53.8 50.9 50.9 0.0 0.0 0.0 0.0 0.0 0.0 Project Name: BECU TRACE® 700 v6.3.2 calculated at 10:11 AM on 04/08/2016 Dataset Name: GTWYBECU.TRC Alternative - 1 System Checksums Report Page 13 of 16 AREAS Capacity Coil Airflow Gross Total Glass MBh cfm 'F ft' (%) Floor 156 78.0 Aux Htg Part 0 0.0 Preheat Int Door 0 0.0 Humidif ExFlr 0 0.0 Opt Vent Roof 0 0 0 Wall 147 50 34 Ext Door 0 0 0 Project Name: BECU TRACE® 700 v6.3.2 calculated at 10:11 AM on 04/08/2016 Dataset Name: GTWYBECU.TRC Alternative - 1 System Checksums Report Page 13 of 16 HEATING COIL SELECTION Capacity Coil Airflow Ent Lvg, MBh cfm 'F °F' Main Htg -2.8 208 65.8 78.0 Aux Htg 0.0 0 0.0 0.0 Preheat 0.0 0 0.0 0.0 Humidif 0.0 0 0.0 0.0 Opt Vent 0.0 0 0.0 0.0 Total -2.8 Project Name: BECU TRACE® 700 v6.3.2 calculated at 10:11 AM on 04/08/2016 Dataset Name: GTWYBECU.TRC Alternative - 1 System Checksums Report Page 13 of 16 Room Checksums By MACDONALD-MILLER 215 Office COOLING COIL PEAK COOLING COIL SELECTION CLG SPACE PEAK Sens Cap. Coil Airflow HEATING COIL PEAK ton MBh TEMPERATURES Peaked at Time: Mo/Hr: 7 / 18 76.4 60.5 Mo/Hr: 7/18 Mo/Hr: Heating Design Opt Vent 0.0 0.0 0.0 0 Cooling Heating Outside Air: OADB/WB/HR: 78 / 64 / 67 0.0 OADB: 78 0 OADB: 24 297 SADB 55.0 79.8 0 0 0 Ra Plenum 75.7 69.8 Space Plenum Net Percent Space Percent Space Peak Coil Peak Percent Return 75.7 69.8 Sens. + Lat. Sens. + Lat Total Of Total Sensible Of Total Space Sens Tot Sens Of Total Ret/OA 75.8 66.7 Btu/h Btu/h Btu/h (%) Btu/h (%) Btu/h Btu/h (%) Fn MtrTD 0.2 0.0 Envelope Loads Envelope Loads Fn BIdTD 0.4 0.0 Skylite Solar 0 0 0 0 0 0 Skylite Solar 0 0 0.00 Fn Frict 1.3 0.0 Skylite Cond 0 0 0 0 0 0 Skylite Cond 0 0 0.00 Roof Cond 0 0 0 0 0 0 Roof Cond 0 0 0.00 Glass Solar 4,190 0 4,190 60 4,190 73 Glass Solar 0 0 0.00 AIRFLOWS Glass/Door Cond 76 0 76 1 76 1 Glass/Door Cond -1,681 -1,681 44.88 Cooling Heating Wall Cond 355 222 577 8 355 6 Wall Cond -374 -611 16.30 Partition/Door 0 0 0 0 0 Partition/Door 0 0 0.00 Diffuser 255 255 Floor 0 0 0 0 0 Floor 0 0 0.00 Terminal 255 255 Adjacent Floor 0 0 0 0 0 0 Adjacent Floor 0 0 0.00 Main Fan 255 255 Infiltration 94 94 1 21 0 Infiltration -351 -351 9.37 Sec Fan 0 0 Sub Total =_> 4,714 222 4,937 71 4,642 81 Sub Total =_> -2,406 -2,643 70.55 Nom Vent 18 18 AHU Vent 18 18 Internal Loads Internal Loads Infil 7 7 Lights 410 102 512 7 410 7 Lights 0 0 0.00 MinStop/Rh 0 0 People 250 0 250 4 125 2 People 0 0 0.00 Return 262 262 Misc 500 0 500 7 500 9 Misc -375 -375 10.01 Exhaust 24 24 Sub Total =_> 1,160 102 1,262 18 1,035 18 Sub Total =_> -375 -375 10.01 Rm Exh 0 0 Auxiliary 0 0 Ceiling Load 32 -32 0 0 32 1 Ceiling Load -10 0 0.00 Leakage Dwn 0 0 Ventilation Load 0 0 240 3 0 0 Ventilation Load 0 -900 24.03 Leakage Ups 0 0 Adj Air Trans Heat 0 0 0 0 0 Adj Air Trans Heat 0 0 0 Dehumid, Ov Sizing 0 0 Ov/Undr Sizing 0 0 0.00 Ov/Undr Sizing 3 3 0 3 0 Exhaust Heat 6 -0.15 ENGINEERING CKS Exhaust Heat -19 -19 0 OA Preheat Diff. 0 0.00 Sup. Fan Heat 530 8 RA Preheat Diff. 0 0.00 Cooling Heating Ret. Fan Heat 0 0 0 Additional Reheat 0 0.00 % OA 6.9 6.9 Duct Heat Pkup 0 0 0 System Plenum Heat 166 -4.44 cfm/ft' 1.70 1.70 Underflr Sup Ht Pkup 0 0 Underflr Sup Ht Pkup 0 0.00 cfm/ton 440.65 Supply Air Leakage 0 0 0 Supply Air Leakage 0 0.00 ft'/ton 258.89 Btulhr•ft' 46.35 -24.98 Grand Total ==> 5,909 274 6,953 100.00 5,712 100.00 Grand Total ==> -2,791 -3,747 100.00 No. People 1.0 6.7/1000 ft' Total 0.6 7.0 Project Name: BECU Dataset Name: GTWYBECU.TRC Leave DB/WB/HR °F °F gr/Ib 53.8 50.8 50.2 0.0 0.0 0.0 0.0 0.0 0.0 COOLING COIL SELECTION Total Capacity Sens Cap. Coil Airflow Enter DB/WB/HR ton MBh MBh cfm °F °F gr/Ib Main Clg 0.6 7.0 6.6 255 76.4 60.5 53.0 Aux CIg 0.0 0.0 0.0 0 0.0 0.0 0.0 Opt Vent 0.0 0.0 0.0 0 0.0 0.0 0.0 Total 0.6 7.0 Project Name: BECU Dataset Name: GTWYBECU.TRC Leave DB/WB/HR °F °F gr/Ib 53.8 50.8 50.2 0.0 0.0 0.0 0.0 0.0 0.0 TRACE® 700 v6.3.2 calculated at 10:11 AM on 04/08/2016 Alternative - 1 System Checksums Report Page 14 of 16 AREAS Gross Total Glass Lvg MBh cfm ft' (%) Floor 150 66.7 79.8 Part 0 0.0 0.0 Int Door 0 0.0 0.0 ExFlr 0 0.0 0.0 Roof 0 0 0 Wall 297 90 30 Ext Door 0 0 0 TRACE® 700 v6.3.2 calculated at 10:11 AM on 04/08/2016 Alternative - 1 System Checksums Report Page 14 of 16 HEATING COIL SELECTION Capacity Coil Airflow Ent Lvg MBh cfm °F °F' Main Htg -3.8 255 66.7 79.8 Aux Htg 0.0 0 0.0 0.0 Preheat 0.0 0 0.0 0.0 Humidif 0.0 0 0.0 0.0 Opt Vent 0.0 0 0.0 0.0 Total -3.8 TRACE® 700 v6.3.2 calculated at 10:11 AM on 04/08/2016 Alternative - 1 System Checksums Report Page 14 of 16 Room Checksums By MACDONALD-MILLER 216 Conference COOLING COIL PEAK COOLING COIL SELECTION CLG SPACE PEAK Sens Cap. Coil Airflow HEATING COIL PEAK ton MBh TEMPERATURES Peaked at Time: Mo/Hr: 7 / 17 77.1 62.6 Mo/Hr: 8/17 Mo/Hr: Heating Design Opt Vent 0.0 0.0 0.0 0 Cooling Heating Outside Air: OADB/WB/HR: 80 / 65 / 67 30 OADB: 80 0 OADB: 24 -7.5 SADB 55.0 77.1 Ra Plenum 75.7 69.8 Space Plenum Net Percent Space Percent Space Peak Coil Peak Percent Return 75.7 69.8 Sens. + Lat. Sens. + Lat Total Of Total Sensible Of Total Space Sens Tot Sens Of Total Ret/OA 76.5 60.6 Btu/h Btu/h Btu/h (%) Btu/h (%) Btu/h Btu/h (%) Fn MtrTD 0.2 0.0 Envelope Loads Envelope Loads Fn BIdTD 0.4 0.0 Skylite Solar 0 0 0 0 0 0 Skylite Solar 0 0 0.00 Fn Frict 1.3 0.0 Skylite Cond 0 0 0 0 0 0 Skylite Cond 0 0 0.00 Roof Cond 0 0 0 0 0 0 Roof Cond 0 0 0.00 Glass Solar 3,801 0 3,801 30 3,830 42 Glass Solar 0 0 0.00 AIRFLOWS Glass/Door Cond 122 0 122 1 126 1 Glass/Door Cond -1,597 -1,597 21.19 Cooling Heating Wall Cond 308 190 498 4 314 3 Wall Cond -367 -596 7.91 Partition/Door 0 0 0 0 0 Partition/Door 0 0 0.00 Diffuser 410 410 Floor 0 0 0 0 0 Floor 0 0 0.00 Terminal 410 410 Adjacent Floor 0 0 0 0 0 0 Adjacent Floor 0 0 0.00 Main Fan 410 410 Infiltration 121 121 1 63 1 Infiltration -609 -609 8.08 Sec Fan 0 0 Sub Total =_> 4,352 190 4,542 35 4,333 47 Sub Total =_> -2,572 -2,802 37.19 Nom Vent 82 82 AHU Vent 82 82 Internal Loads Internal Loads Infil 12 12 Lights 710 177 887 7 710 8 Lights 0 0 0.00 MinStop/Rh 0 0 People 3,384 0 3,384 26 1,634 18 People 0 0 0.00 Return 422 422 Misc 2,000 0 2,000 16 2,000 22 Misc -650 -650 8.63 Exhaust 94 94 Sub Total =_> 6,094 177 6,272 49 4,344 47 Sub Total ==> -650 -650 8.63 Rm Exh 0 0 Auxiliary 0 0 Ceiling Load 55 -55 0 0 56 1 Ceiling Load -17 0 0.00 Leakage Dwn 0 0 Ventilation Load 0 0 837 7 0 0 Ventilation Load 0 -4,219 56.00 Leakage Ups 0 0 Adj Air Trans Heat 0 0 0 0 0 Adj Air Trans Heat 0 0 0 Dehumid. Ov Sizing 0 0 Ov/Undr Sizing 0 0 0.00 Ov/Undr Sizing 439 439 3 439 5 Exhaust Heat 22 -0.29 ENGINEERING CKS Exhaust Heat -71 -71 -1 OA Preheat Diff. 0 0.00 Sup. Fan Heat 850 7 RA Preheat Diff. 0 0.00 Cooling Heating Ret. Fan Heat 0 0 0 Additional Reheat 0 0.00 % OA 20.0 20.0 Duct Heat Pkup 0 0 0 System Plenum Heat 115 -1.52 cfm/ft, 1.58 1.58 Underfir Sup Ht Pkup 0 0 Underflr Sup Ht Pkup 0 0.00 cfm/ton 382.33 Supply Air Leakage 0 0 0 Supply Air Leakage 0 0.00 ft'/ton 242.45 Btu/heft' 49.49 -28.98 Grand Total ==> 10,940 242 12,869 100.00 9,172 100.00 Grand Total ==> -3,239 -7,535 100.00 No. People 10.0 38.5/1000 ft2 Total 1.1 12.9 Project Name: BECU Dataset Name: GTWYBECU.TRC Leave DB/WB/HR' °F °F gr/Ib 53.8 51.8 54.0 0.0 0.0 0.0 0.0 0.0 0.0 AREAS COOLING COIL SELECTION Total Capacity Sens Cap. Coil Airflow Enter DB/WBIHR ton MBh MBh cfm °F °F gr/Ib Main Clg 1.1 12.9 10.7 410 77.1 62.6 61.5 Aux Clg 0.0 0.0 0.0 0 0.0 0.0 0.0 Opt Vent 0.0 0.0 0.0 0 0.0 0.0 0.0 Total 1.1 12.9 Project Name: BECU Dataset Name: GTWYBECU.TRC Leave DB/WB/HR' °F °F gr/Ib 53.8 51.8 54.0 0.0 0.0 0.0 0.0 0.0 0.0 AREAS HEATING COIL SELECTION Gross Total Glass Ent Lvg ft2 MBh cfm Floor 260 °F Main Htg Part 0 60.6 77.1 Int Door 0 0.0 0 0.0 ExFlr 0 Preheat 0.0 0 Roof 0 0 0 Wall 288 85 30 Ext Door 0 0 0 TRACE® 700 v6.3.2 calculated at 10:11 AM on 04/08/2016 Alternative - 1 System Checksums Report Page 15 of 16 HEATING COIL SELECTION Capacity Coil Airflow Ent Lvg MBh cfm °F °F Main Htg -7.5 410 60.6 77.1 Aux Htg 0.0 0 0.0 0.0 Preheat 0.0 0 0.0 0.0 Humidif 0.0 0 0.0 0.0 Opt Vent 0.0 0 0.0 0.0 Total -7.5 TRACE® 700 v6.3.2 calculated at 10:11 AM on 04/08/2016 Alternative - 1 System Checksums Report Page 15 of 16 Room Checksums By MACDONALD-MILLER 217 Copy COOLING COIL PEAK COOLING COIL SELECTION CLG SPACE PEAK Sens Cap. Coil Airflow HEATING COIL PEAK ton MBh TEMPERATURES Peaked at Time: Mo/Hr: 7 / 16 77.0 61.7 Mo/Hr: 8/16 Mo/Hr: Heating Design Opt Vent 0.0 0.0 0.0 0 Cooling Heating Outside Air: OADB/WB/HR: 81 / 65 / 66 0 OADB: 81 0 OADB: 24 Total SADB 55.0 70.0 Ra Plenum 75.7 69.8 Space Plenum Net Percent Space Percent Space Peak Coil Peak Percent Return 75.7 69.8 Sens. + Lat. Sens. + Lat Total Of Total Sensible Of Total Space Sens Tot Sens Of Total Ret/OA 76.4 64.0 Btu/h Btu/h Btu/h (%) Btu/h (%) Btu/h Btu/h (%) Fn MtrTD 0.2 0.0 Envelope Loads Envelope Loads Fn BIdTD 0.4 0.0 Skylite Solar 0 0 0 0 0 0 Skylite Solar 0 0 0.00 Fn Frict 1.3 0.0 Skylite Cond 0 0 0 0 0 0 Skylite Cond 0 0 0.00 Roof Cond 0 0 0 0 0 0 Roof Cond 0 0 0.00 Glass Solar 0 0 0 0 0 0 Glass Solar 0 0 0.00 AIRFLOWS Glass/Door Cond 0 0 0 0 0 0 Glass/Door Cond 0 0 0.00 Cooling Heating Wall Cond 0 0 0 0 0 0 Wall Cond 0 0 0.00 Partition/Door 0 0 0 0 0 Partition/Door 0 0 0.00 Diffuser 83 83 Floor 0 0 0 0 0 Floor 0 0 0.00 Terminal 83 83 Adjacent Floor 0 0 0 0 0 0 Adjacent Floor 0 0 0.00 Main Fan 83 83 Infiltration 0 0 0 0 0 Infiltration 0 0 0.00 Sec Fan 0 0 Sub Total =_> 0 0 0 0 0 0 Sub Total =_> 0 0 0.00 Nom Vent 10 10 AHU Vent 10 10 Internal Loads Internal Loads Infil 0 0 Lights 153 38 191 8 153 8 Lights 0 0 0.00 MinStop/Rh 0 0 People 381 0 381 16 181 10 People 0 0 0.00 Return 83 83 Misc 1,500 0 1,500 63 1,500 81 Misc 0 0 0.00 Exhaust 10 10 Sub Total =_> 2,034 38 2,073 87 1,834 99 Sub Total =_> 0 0 0.00 Rm Exh 0 0 Auxiliary 0 0 Ceiling Load 12 -12 0 0 12 1 Ceiling Load -4 0 0.00 Leakage Dwn 0 0 Ventilation Load 0 0 150 6 0 0 Ventilation Load 0 -538 96.34 Leakage Ups 0 0 Adj Air Trans Heat 0 0 0 0 0 Adj Air Trans Heat 0 0 0 Dehumid. Ov Sizing 0 0 Ov/Undr Sizing 0 0 0.00 Ov/Undr Sizing 1 1 0 1 0 Exhaust Heat 2 -0.43 ENGINEERING CKS Exhaust Heat -8 -8 0 OA Preheat Diff. 0 0.00 Sup. Fan Heat 171 7 RA Preheat Diff. 0 0.00 Cooling Heating Ret. Fan Heat 0 0 0 Additional Reheat 0 0.00 % OA 12.7 12.7 Duct Heat Pkup 0 0 0 System Plenum Heat -23 4.09 cfm/ft' 1.47 1.47 Underfir Sup Ht Pkup 0 0 Underflr Sup Ht Pkup 0 0.00 cfm/ton 415.17 Supply Air Leakage 0 0 0 Supply Air Leakage 0 0.00 ft'/ton 281.55 Btu/heft' 42.62 -9.97 Grand Total ==> 2,047 19 2,387 100.00 1,847 100.00 Grand Total ==> -4 -558 100.00 No. People 1.0 17.9/1000 ft' Total 0.2 2.4 Project Name: BECU Dataset Name: GTWYBECU.TRC Leave DB/WB/HR °F °F gr/Ib 53.8 51.6 53.4 0.0 0.0 0.0 0.0 0.0 0.0 AREAS COOLING COIL SELECTION Total Capacity Sens Cap. Coil Airflow Enter DB/WB/HR ton MBh MBh cfm °F °F gr/Ib Main CIg 0.2 2.4 2.1 83 77.0 61.7 57.6 Aux Cig 0.0 0.0 0.0 0 0.0 0.0 0.0 Opt Vent 0.0 0.0 0.0 0 0.0 0.0 0.0 Total 0.2 2.4 Project Name: BECU Dataset Name: GTWYBECU.TRC Leave DB/WB/HR °F °F gr/Ib 53.8 51.6 53.4 0.0 0.0 0.0 0.0 0.0 0.0 AREAS HEATING COIL SELECTION Gross Total Glass Ent Lvg ft' MBh Cfm Floor 56 °F Main Htg Part 0 64.0 70.0 Int Door 0 0.0 0 0.0 ExFlr 0 Preheat 0.0 0 Roof 0 0 0 Wall 0 0 0 Ext Door 0 0 0 TRACE® 700 v6.3.2 calculated at 10:11 AM on 04/08/2016 Alternative - 1 System Checksums Report Page 16 of 16 HEATING COIL SELECTION Capacity Coil Airflow Ent Lvg MBh Cfm °F °F Main Htg -0.6 83 64.0 70.0 Aux Htg 0.0 0 0.0 0.0 Preheat 0.0 0 0.0 0.0 Humidif 0.0 0 0.0 0.0 Dpt Vent 0.0 0 0.0 0.0 Total -0.6 TRACE® 700 v6.3.2 calculated at 10:11 AM on 04/08/2016 Alternative - 1 System Checksums Report Page 16 of 16 r System Zone Room VAV Minimum % Floor Area ft' Load / Airflow Summary By MACDONALD-MILLER Coil Coil Space Cooling Cooling Design People Sensible Total Max SA # Btu/h Btu/h cfm Air Changes ach/hr Alternative 1 0 -1,170 57 15.6 15.6 0 0 201 Quiet Room Rm Peak 36 1.0 1,429 1,641 57 10.49 203a Open Office Rm Peak 1,594 12.0 25,777 29,502 973 4.02 203b Open Office Perim Rm Peak 1,121 9.0 31,045 34,115 1,199 7.05 203c Open Office Perim Rm Peak 916 7.0 22,918 25,578 888 6.39 203d Open Office Rm Peak 3,726 43.0 72,273 84,132 2,741 4.85 210 Mothers Room Rm Peak 46 1.0 1,324 1,570 49 6.95 212 Conference Rm Peak 179 6.0 8,111 9,595 320 11.78 213 Office Rm Peak 155 1.0 5,276 5,670 207 8.82 214 Office Rm Peak 156 1.0 5,294 5,688 208 8.79 215 Office Rm Peak 150 1.0 6,568 6,953 255 11.22 216 Conference Rm Peak 260 10.0 10,682 12,869 410 10.40 217 Copy Rm Peak 56 1.0 2,112 2,387 83 9.72 Large RTU Zn Peak 8,395 93.0 192,810 219,698 7,389 1,987 Large RTU Zn Block 8,395 93.0 186,450 213,682 7,389 17.7 200 Breakout Rm Peak 306 3.0 8,821 9,714 341 7.34 202a Open Office Rm Peak 396 6.0 10,871 12,381 433 7.22 202b Open Office Rm Peak 588 6.0 10,774 12,479 408 4.58 205 Break Room Rm Peak 479 20.0 20,926 25,505 805 11.08 Small RTU Zn Peak 1,769 35.0 51,392 60,080 1,987 Small RTU Zn Block 1,769 35.0 49,159 58,459 1,987 System - 001 Sys Peak 10,164 128.0 244,202 279,778 9,376 System - 001 Sys Block 10,164 128.0 234,949 271,332 9,376 " This report does not display heating only systems. Project Name: BECU Dataset Name: GTWYBECU.TRC VAV Minimum SA cfm VAV Minimum % Main Coil Heating Sensible Btu/h Heating Fan Max SA cfm Percent OA Clg Htg 0 0 -1,170 57 15.6 15.6 0 0 -10,295 973 20.0 20.0 0 0 -18,853 1,199 11.7 11.7 0 0 -15,134 888 12.7 12.7 0 0 -28,960 2,741 20.0 20.0 0 0 -920 49 20.0 20.0 0 0 -4,702 320 15.9 15.9 0 0 -2,830 207 8.6 8.6 0 0 -2,839 208 8.6 8.6 0 0 -3,747 255 6.9 6.9 0 0 -7,535 410 20.0 20.0 0 0 -558 83 12.7 12.7 0 -97,542 7,389 16.4 16.4 0 -97,542 7,389 16.4 16.4 0 0 -6,333 341 12.2 12.2 0 0 -7,700 433 15.5 15.5 0 0 -4,313 408 20.0 20.0 0 0 -8,461 805 20.0 20.0 0 -26,807 1,987 17.7 17.7 0 -26,807 1,987 17.7 17.7 -124,349 9,376 16.7 16.7 -124,349 9,376 16.7 16.7 TRACE@ 700 v6.3.2 calculated at 10:11 AM on 04/08/2016 Load/Airflow Summary Report Page 1 of 1 ?ERN31T CORD COPY PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: M16-0053 DATE: 04/18/16 PROJECT NAME: GATEWAY/BLDG9BECU SITE ADDRESS: 13035 GATEWAY DR X Original Plan Submittal Response to Correction Letter # DEPARTMENTS: Building Division Revision # before Permit Issued Revision # after Permit Issued '"//.- y- Fire Prevention 0 Planning Division ❑ Public Works ❑ Structural ❑ Permit Coordinator ❑ PRELIMINARY REVIEW: DATE: 04/19/16 Not Applicable ❑ Structural Review Required ❑ (no approval/review required) REVIEWER'S INITIALS: APPROVALS OR CORRECTIONS: Approved ❑ Corrections Required ❑ (corrections entered in Reviews) Notation: REVIEWER'S INITIALS: DATE: DUE DATE: 05/17/16 Approved with Conditions Denied ❑ (ie: Zoning Issues) DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: 12/18/2013 MACDONALD/MILLER FAC SOT TNC mom Washington State Department of Labor & Industries Page 1 of 3 Home f spsahol Contract Search L&I A-% Indes Help MY LCT Safety & Health Claims & Insurance Workplace Rights Trades & Licensing MACDONALD/MILLER FAC SOL INC Owner or tradesperson PO BOX 47983 SEATTLE, WA 98106 Principals 206-768-4180 SIMONDS, DERRICK R, PRESIDENT KING County WEBSTER, MARK E, VICE PRESIDENT GEBHARDT, STEPHANIE WETTACH,TREASURER HOEL, STEPHANIE W, MEMBER SIGMUND, FREDRIC, PRESIDENT (End: 01 /04/2011) LOVELY, STEVE C, VICE PRESIDENT (End: 01 /04/2011) HACK, RICHARD, SECRETARY (End: 01 /04/2011) KOPET, TYLER, TREASURER (End: 01 /04/2011) TURLEY, DOUGLAS, CHIEF EXECUTIVE OFFICER (End: 01/04/2011) TURLEY, DOUGLAS, CHIEF OPERATING OFFICER (End: 01/04/2011) GOUGH, DAVID ANTHONY, DIRECTOR (End: 08/29/2014) Doing business as MACDONALD/MILLER FAC SOL INC WA UBI No. Business type 602 254 260 Corporation Governing persons FREDRIC J SIGMUND STEVE C LOVELY; TYLER C KOPET; License Verify the contractor's active registration / license / certification (depending on trade) and any past violations. Construction o .................................Contract........................r. Active. Meets current requirements. License specialties GENERAL License no. MACDOFS980RU Effective — expiration 12/3112002— 01/03/2017 https:Hsecure.Ini.wa.gov/verify/Detail.aspx?UBI=602254260&LIC=MACDOFS98ORU&SAW= 5/9/2016 0 CD 3 0 0 M N f0 t0 M L V) c •c m m rn w 1 i 0 m w M I a rn v m :-, 0 3 m c 0 a N CD M n 0 N co 0 N C6 O ABBV FULL NAME ABBV FULL NAME ABBV FULL NAME A COMPRESSED AIR LINE ESP EXTERNAL STATIC PRESSURE OSA OUTSIDE AIR AC AIR CONDITIONING UNIT EXH EXHAUST OBD OPPOSED BLADE DAMPER AD ACCESS DOOR (WALL/ROOFIDUCT - SEE DRAWING) EXTR EXTRACTOR OD OUTSIDE DIMENSION AFF ABOVE FINISHED FLOOR FAC FIRE ALARM CONTRACTOR RA RETURN AIR AL ALUMINUM FD FIRE DAMPER REG REGISTER (GRILLE WITH DAMPER) BOO BACKDRAFT DAMPER FLA FULL LOAD AMPS REQ'D REQUIRED BOB BOTTOM OF BEAM FOB FLAT ON BOTTOM RIO ROUGH IN ONLY BOD BOTTOM OF DUCT FOT FLAT ON TOP SA SUPPLY AIR BOTT BOTTOM FRD FRICTION DAMPER SCD SMOKE CONTROL DAMPER BTU BRITISH THERMAL UNITS FSD FIRE SMOKE DAMPER SD SMOKE DAMPER BTUH BRITISH THERMAL UNITS PER HOUR G GAS LINE SL SOUND LINING BWG BOTTOM WALL GRILLE GALV GALVANIZED SM SHEET METAL BWR BOTTOM WALL REGISTER GC GENERAL CONTRACTOR SP STATIC PRESSURE C CONDENSATE GPM GALLONS PER MINUTE SS START/STOP CAP CAPACITY GR GRILLE SSSC SOLID STATE SPEED CONTROLLER CC CONTROLS CONTRACTOR GWB GYPSUM WALL BOARD STL STEEL CFM CUBIC FEET PER MINUTE HG HOT GAS LINE SUC SUCTION LINE CHWR CHILLED WATER RETURN HP HORSE POWER SUSP SUSPENDED CHWS CHILLED WATER SUPPLY HWR HOT WATER RETURN T'STAT THERMOSTAT COMB COMBUSTION HWS HOT WATER SUPPLY TC TEMPERATURE CONTROL CONN CONNECT ID INSIDE DIMENSION TOD TOP OF DUCT CWR CONDENSER WATER RETURN INT INTERLOCK TOS TOP OF STEEL CWS CONDENSER WATER SUPPLY LIQ LIQUID LINE TV TURN VANES DB DUCT BOARD M -M MACDONALD-MILLER TWG TOP WALL GRILLE DIFF DIFFUSER MBH ONE THOUSAND BTUH TWR TOP WALL REGISTER DMPR DAMPER MC MECHANICAL CONTRACTOR TYP TYPICAL DN DOWN MCA MINIMUM CIRCUIT AMPACITY UNO UNLESS NOTED OTHERWISE EC ELECTRICAL CONTRACTOR MD MOTORIZED DAMPER VD VOLUME DAMPER EGG EGGCRATE MIN MINIMUM VFD VARIABLE FREQUENCY DRIVE EER ENERGY EFFICIENCY RATIO MT MOUNT 0 VOLTAGE PHASE & DUCT DIAMETER ELEV ELEVATION MUA MAKE-UP AIR EMS ENERGY MANAGEMENT SYSTEM NOM NOMINAL SYMBOL DESCRIPTION -POWERED NOTES SYMBOL DESCRIPTION -NON POWERED 1 NOTES MD--1M BLADESMOTORZED GR ENHECK VCD-33 OR EQUAL CONTROL DAMPER: MEDIUM VELOCITY AIRFOIL 4 I 1. ACTUATOR BY MECHANICAL CONTRACTOR, WIRING BY ELECTRICAL CONTRACTOR 2. INTERLOCK OF SMOKE DAMPER TO FIRE ALARM SYSTEM BY ELECTRICAL CONTRACTOR 3. CONTROL FROM LOCAL DETECTOR 4. CONTROL FROM DUCT DETECTOR 5. OPEN/CLOSED POSITION INDICATOR 6. DAMPER FAILS OPEN 7. DAMPER FAILS CLOSED DESCRIPTION SYMBOL DESCRIPTION SYMBOL BARE SHEETMETAL ESP ( ROUND SHEETMETAL WRAPPED W/ INSULATION (2") OA CFM 14X12 120W SLOT DIFFUSER WT LBS SOUNDLINE SHEETMETAL (1" LINING) NOTES ( CLEANROOM QUALITY DUCTWORK C CFM SHOEMAKER 905 -DW 1 AS NOTED 14X12SL 14x12C IZE SHOEMAKER 904 AS NOTED CFM DOUBLE DEFLECTION SIDEWALL DIFFUSER SHEETMETAL WRAPPED W/ INSULATION (2") 6f I M -M METAL EGGCRATE 12/24 BARE FLAT OVAL SHEETMETAL 14x120 14x 12W RETURNIEXH 460/3 63.1 BARE ROUND SHEETMETAL EXISITING i FLAT OVAL FLAT SHEETMETAL W/ INSULATION (2") RTU -0302 120 14X 120W 60.0 47.0 ( 1,500 EXPOSED QUALITY SHEETMETAL 950W DUCTBOARD (1" FIBERGLASS) - 14x12Q 14x 12DB 355 - EXAMPLE OF NEW EXISITING ( EXAMPLE OF NOT IN CONTRACT (NIC) 1402 14X 12 CHGR EXAMPLE OF DEMO X X X X Y FLEX DUCT EXISITING X EXAMPLE OF EXISTING CARRIER FLEX CONNECTOR 12 14X12 125 SYMBOL '; MANUFACTURER & MODEL NUMBER SIZE TYPE NOTES SHOEMAKER 701 AS NOTED T -BAR LAY -IN MODULAR CORE DIFFUSER ESP -MA CFM 1 OA CFM EER/ EER BBM SHOEMAKER LSD -LP AS NOTED SLOT DIFFUSER WT LBS CURB WEIGHT NOTES INPUT OUTPUT C CFM SHOEMAKER 905 -DW 1 AS NOTED SURFACE MT RET/EXH GRILLE CARRIER48DPO20620 IZE SHOEMAKER 904 AS NOTED CFM DOUBLE DEFLECTION SIDEWALL DIFFUSER 7,330 6f I M -M METAL EGGCRATE 12/24 RETURN/EXH 1466 M -M METAL EGGCRATE 24/24 RETURNIEXH 460/3 63.1 ROOFTOP UNIT COVERAGE AREA: 7 FT2 (NEW UNITS) + 1036 FT2 (OLD UNITS) =1043 FT2 PERCENTAGE COVERED BY UNITS: 1043 FT2 / 41,616 FT2 (FOOTPRINT) = 2.51 % INDOOR UNIT ! OUTDOOR UNIT UNIT ; NOM. ELECTRICAL WT ELECTRICAL WT NO. _ MANUFACTURER _ MODEL _ TONS CFM SEER VOLT/PH FLA LBS MODEL CFM VOLT/PH MOCP MCA LBS _ NOTES__ FCU -0201 FUJITSU i ASU36RLXB j 3.00 - 15.50 208-230/1 - 31 AOU36RLXB - 208-230/1 30 23.3 134 NEW,1 6 NOTES: 1. PROVIDE WITH WIRELESS TSTAT. 2. INSTALL IN ACCORDANCE WITH MANUFACTURER'S RECOMMENDATIONS AND DETAILS ON DRAWINGS. 3. PROVIDE 3/4" TYPE L COPPER CONDENSATE DRAIN TO BUILDING EXTERIOR OR NEAREST SINK TAILPIECE 4. INDOOR UNITS FACTORY WIRED AND CIRCUIT PROTECTED FOR SINGLE POINT ELECTRICAL CONNECTION OFF OUTDOOR UNIT. 5. NO ECONOMIZER PER WSEC 403.3.1 EXCEPTION 45. 6. SOUND PRESSURE 3' FROM CU UNIT IS 55 DB, LESS THAN THE REQUIRED 60 DB @ PROPERTY LINE. UNIT NO. MFG & MODEL NO. NOM TOS GAS HEAT MBH I CFM ESP FAN HP OA CFM EER/ EER SEER IRICAL WT LBS CURB WEIGHT NOTES INPUT OUTPUT VOLT PHMCA RTU -0301 CARRIER48DPO20620 18.0 270.0 216.0 7,330 1.40 5.00 1466 8.2/ - 460/3 63.1 2440 EXISITING EXISTING, 1-2 RTU -0302 CARRIER 48GS-042060601 1 3.5 60.0 47.0 ( 1,500 0.40 950W 300 - /10.00 1 460/3 9.5 355 - EXISTING, 1 NOTES: 1. NO CHANGE TO EXISTING ROOFTOP UNIT. FOR REFERENCE. 2. EXISTING SMOKE DETECTOR. 1. THESE PLANS ARE SCHEMATIC AND DO NOT SHOW EXACT ROUTING OR EVERY OFFSET WHICH MAY BE REQUIRED. THE HVAC CONTRACTOR IS TO COORDINATE WITH ALL OTHER TRADES AND IS TO VERIFY ALL CLEARANCES BEFORE COMMENCING WORK. 2. MATERIALS, METHODS, AND INSTALLATION SHALL COMPLY WITH THE PROVISIONS OF THE 2012 EDITIONS OF THE INTERNATIONAL MECHANICAL CODE, INTERNATIONAL BUILDING CODE, INTERNATIONAL FIRE CODE AND STATE AND LOCAL CODES AND ORDINANCES. 3. DUCT CONSTRUCTION AND HANGING SHALL COMPLY WITH CHAPTER 6 OF THE 2012 IMC AND WITH CURRENT SMACNA STANDARDS. EARTHQUAKE BRACE ALL DUCTS 28" DIA AND LARGER WHICH ARE SUSPENDED MORE THAN 12" BELOW STRUCTURAL SYSTEM. 4. JOINTS OF MEDIUM AND HIGH VELOCITY DUCT SYSTEMS SHALL BE SEALED WITH GASKETS OR LISTED MASTIC TYPE DUCT SEALANT. 5. DUCTS SHALL BE INSULATED AS INDICATED ON PLANS, PER 2012 WASHINGTON STATE ENERGY CODE, COMMERCIAL PROVISIONS DUCT WRAP, WHERE INDICATED, SHALL BE 11/2' 0.75 LB/CU FT FIBERGLASS DUCT INSULATION WITH A FACTORY APPLIED REINFORCED ALUM. FOIL VAPOR BARRIER (R-6 MIN.). - SOUND LINING, WHERE INDICATED, SHALL BE 1" 1.5 LB/CU FT FIBERGLASS DUCT LINING COATED TO PREVENT FIBER EROSION AT VELOCITIES UP TO 6000 FPM (R-6 MIN.). DUCT BOARD, WHERE INDICATED, SHALL BE 1" RIGID FRK FACED EI 475 FIBERGLASS DUCT BOARD SYSTEM, UL 181 LISTED AS A CLASS 1 AIR DUCT (R6 MIN.). AIR DUCT (R6 MIN) SUPPLY DUCT WHICH CONVEY SUPPLY AIR AT TEMPERATURES LESS THAN 55 DEG F OR GREATER THAN 105 DEG F SHALL BE INSULATED WITH A MINIMUM OF R-3.3, WHEN LOCATED IN CONDITIONED SPACE. 6. FLEX DUCTS SHALL CONSIST OF A REINFORCED VAPOR BARRIER, 11/2' FIBERGLASS INSULATION, AND NON -PERFORATED INTERIOR LINER WITH WIRE HELIX. DUCT SHALL BE A UL 181 LISTED CLASS 1 AIR DUCT. FLEX DUCTS SHALL ONLY BE USED WHERE SHOWN AND SHALL NOT EXCEED 12' IN LENGTH UNLESS NOTED OTHERWISE. 7. PROVIDE EARTHQUAKE RESTRAINT FOR HVAC EQUIPMENT IN ACCORDANCE WITH SECTION 1613 OF THE 2012 IBC. 8. PROVIDE FIRE DAMPERS, SMOKE DAMPERS AND FIREISMOKE DAMPERS WHERE INDICATED ON PLANS AND AS REQUIRED BY SECTION 717.5 OF THE 2012 IBC. PROVIDE CEILING FIRE DAMPERS WHERE INDICATED ON PLANS AND AS REQUIRED BY SECTION 717.6.2.1 OF THE 2012 IBC. INSTALL FIRE DAMPERS SMOKE DAMPERS AND FIRE/SMOKE DAMPERS IN ACCORDANCE WITH THE MANUFACTURERS INSTRUCTIONS, THE TERMS OF THEIR LISTING, AND THE REQUIREMENTS OF THE CODE. 9. PIPING PENETRATIONS OF FIRE RATED WALLS OR FLOORS SHALL BE SLEEVED AND FIRE STOPPED WITH LISTED MATERIALS SO AS TO MAINTAIN THE INTEGRITY AND RATING OF THE FLOOR OR WALL. 10. PROVIDE RETURN DUCT SMOKE DETECTOR AUTOMATIC SHUT DOWN OF ALL NEW HEATING, COOLING, OR VENTILATION EQUIPMENT MOVING IN EXCESS OF 2000 CFM IN ACCORDANCE WITH SECTION 606 OF THE 2012 IMC. POWER AND INTERLOCK WIRING WITH THE BUILDING FIRE ALARM SYSTEM IS BY THE ELECTRICAL CONTRACTOR. 11. HVAC EQUIPMENT, VALVES AND DAMPERS SHALL BE LOCATED IN EASILY ACCESSIBLE LOCATIONS. UNLESS SHOWN ON ARCHITECTURAL DRAWINGS, REQUIRED ACCESS PANELS SHALL BE PROVIDED AND INSTALLED BY THE GENERAL CONTRACTOR. MINIMUM ACCESS DOOR SIZE FOR VALVES AND DAMPERS TO BE 18"X 18". 12. HEAT TRACING OF PIPING, WHERE INDICATED, SHALL BE PROVIDED AND INSTALLED BY THE HVAC CONTRACTOR. THE HVAC CONTRACTOR IS TO COORDINATE THE HEAT TRACE POWER WIRING WITH ELECTRICAL CONTRACTOR. 13. MOTORS STARTERS NOT LISTED AS BEING PROVIDED IN THE HVAC EQUIPMENT SCHEDULES ARE TO BE PROVIDED AND INSTALLED BY ELECTRICAL CONTRACTOR. 14. WITHIN 90 DAYS AFTER THE DATE OF SYSTEM ACCEPTANCE, RECORD DRAWINGS OF THE ACTUAL INSTALLATION TO BE PROVIDED TO THE BUILDING OWNER. RECORD DRAWINGS SHALL INCLUDE AS A MINIMUM THE LOCATION AND PERFORMANCE DATA ON EACH PIECE OF EQUIPMENT, GENERAL CONFIGURATION OF DUCT AND PIPE DISTRIBUTION SYSTEM, INCLUDING SIZES, AND THE TERMINAL AIR AND WATER DESIGN FLOW RATES. 15. OPERATING AND MAINTENANCE MANUALS TO BE PROVIDED TO THE BUILDING OWNER THAT INCLUDE: SUBMITTAL DATA, NAMES AND ADDRESSES OF AT LEAST ONE SERVICE AGENCY, HVAC CONTROLS SYSTEM MAINTENANCE AND CALIBRATION INFORMATION AND A COMPLETE OPERATIONAL NARRATIVE FOR EACH SYSTEM. 16. COMMISSIONING IS REQUIRED ON THIS PROJECT IN ACCORD WITH WASHINGTON STATE ENERGY CODE (WSEC), COMMERCIAL PROVISIONS, SECTION C408 AND WITH LEED NC -2.1 FUNDAMENTAL BUILDING SYSTEMS COMMISSIONING AND ADDITIONAL COMMISSIONING. 17. A COMPLETE REPORT OF TEST PROCEDURES AND RESULTS SHALL BE PREPARED AND FILED WITH THE OWNER 18. FOR ALL "SEALED AIR TIGHT" SHAFTS OR ROOMS, THE FOLLOWING MUST OCCUR: - ALL VERTICAL JOINTS INSIDE THE SHAFT SHOULD BE PROVIDED WITH A CONTINUOUS SEAL FOR THE LENGTH OF THE JOINT, INCLUDING THE SHAFT CORNERS (BY GC). - TOP AND BOTTOM WALL TRACKS SHOULD BE CAULKED ALONG THEIR ENTIRE LENGTH (BY GC). - ANY FLOOR DECKING PERPENDICULAR TO THE SHAFT SHOULD BE CAULKED. FILLING WITH ROCK WOOL OR FIRESAFING ("MONOCOAT") IS NOT ACCEPTABLE (BY GC). - ANY PENETRATIONS OF THE SHAFT CONSTRUCTION (DUCTWORK, CONDUIT, PIPING) SHOULD BE SEALED WITH FIRE CAULKING ON BOTH SIDES OF THE PENETRATION. - USE SECTION 909.5 OF THE 2012 IBC FOR MAXIMUM ALLOWABLE LEAKAGE AREA, FOLLOWING THE GUIDELINES FOR SMOKE BARRIER CONSTRUCTION. - ALL DOORS MUST BE PROVIEDED WITH TIGHT FITTING GASKETS, AND OPEN AGAINST THE DIRECTION OF ROOM/SHAFT PRESSURE. 19. DAMPERS USED FOR OUTDOOR AIR INTAKE, EXHAUST, OR RELIEF SHALL HAVE THE FOLLOWING MAXIMUM LEAKAGE RATES AT 1" W.G. (PER AMCA STANDARD 500D): MOTORIZED DAMPERS: 4 CFM/S.F. GRAVITY DAMPERS: 20CFM/S.F. (40 CFM/S.F. FOR DAMPERS SMALLER THAN 24" IN EITHER DIMENSION). 20. OUTSIDE AIR INTAKE, EXHAUST, AND RELIEF DAMPERS SERVING CONDITIONED SPACES MUST BE MOTORIZED (FAIL CLOSED) PER WSEC, COMMERCIAL PROVISIONS, SECTION C402.4.5.2 AND 0403.2.4.4. EXCEPT AS ALLOWED BY WSEC. APN#:0004800015 �- LEGAL DESCRIPTION: LEWIS C C DC # 37 POR OF C C LEWIS DONATION CLAIM NO 37 TGW ! i�'R OF STEPHEN FOSTER DONATION CLAIM NO 38 IN SECTIONS 1n. 11, 14 & 15 TWP 23 RANGE 4 - BAAP BEARING N40 -01-05W 920.15FT FROM A MONUMENT AT PT OF INTSN OF CURVE ON C/L OF DUWAMISH- RENTON JUNCTION RD BEING APPROX 1000 FT E & 20 FT S OF QUARTER CORNER BETWEEN SECTIONS 14 & 15 TH N 49-24-00 W 835 FT ON A LINE PLT & 150 FT NELY OF C/L OF DUWAMISH-RENTON JUNCTION RD TAP BEARING N 81-44-5,5 E 199.17 FT FR POINT OF CURVE ON C/L OF DUWAMISH = RENTON JUNCTION RD SD PT OF CURVE BEING APPROX 1200 FT N & 440 FT W OF QUARTER CORNER BETWEEN SECTIONS 14 & 15 TH S 40-36-00 W 20 FT TO NELYMGN OF RNV OF PUGET SOUND ELECTRIC RAILWAY TH N 49-24-00 W 980.29 FT TH S 49-24-00 E 400 FT TH N 40-36-00 E 190 FT TO POB TH N 40-36-00 E 512.10 FT TH N 49-24-00 W 325 FT TH S 79-15-35 W 12.81 FT TH N 49-24-00 W 67 FT TH S 40-36-00 W 502.10 FT TAP BEARING N 49-24-00 W 400 FT FR POB TH S 49-24-00 E 400 FT TO POB - AICA LOT 2 OF CITY OF TUKWILA BDRY LINE ADJ NO 91-4-BLA RECORDING NO 9105231162 PLat Block: Plat Lot: POR jo Manges shall be made to the SaW Of mrk without prior ap2mvel of I -7711U ing Uivision. MOM: Revisions will require a nets plan submittal TITLE NAME COMPANY PHONE NUMBER EMAIL PROJECT ENGINEER TYLER VANDOOREN UNIT NO. AREA OR UNIT SERVED MFG & MODEL NO. TYPE INLET SIZE VALVE CFM MAX MIN NOTES VVT-0201 SW PERIMETER OPEN OFFICE CARRIER CHGR 16 1550 390 EXISITING VVT-0202 SE PERIMETER OPEN OFFICE CARRIER CHGR 14 1110 280 EXISITING VVT-0203 OPEN OFFICE CARRIER CHGR 14 1100 275 EXISITING VVT-0204 OPEN OFFICE CARRIER CHGR 14 ( 1100 275 EXISITING VVT-0205 OPEN OFFICE CARRIER CHGR 16 980 245 EXISITING VVT-0206 ( CONFERENCE/COPY CARRIER CHGR 12 495 125 EXISITING VVT-0207 SW PERIMETER OFFICES CARRIER CHGR 12 995 250 EXISITING ISSUE DAM R VILLANUEVA 04-08-16 DRAWING NUMBER: NOTES: 1. SHEET NUMBER: TM10-01.1 1. THESE PLANS ARE SCHEMATIC AND DO NOT SHOW EXACT ROUTING OR EVERY OFFSET WHICH MAY BE REQUIRED. THE HVAC CONTRACTOR IS TO COORDINATE WITH ALL OTHER TRADES AND IS TO VERIFY ALL CLEARANCES BEFORE COMMENCING WORK. 2. MATERIALS, METHODS, AND INSTALLATION SHALL COMPLY WITH THE PROVISIONS OF THE 2012 EDITIONS OF THE INTERNATIONAL MECHANICAL CODE, INTERNATIONAL BUILDING CODE, INTERNATIONAL FIRE CODE AND STATE AND LOCAL CODES AND ORDINANCES. 3. DUCT CONSTRUCTION AND HANGING SHALL COMPLY WITH CHAPTER 6 OF THE 2012 IMC AND WITH CURRENT SMACNA STANDARDS. EARTHQUAKE BRACE ALL DUCTS 28" DIA AND LARGER WHICH ARE SUSPENDED MORE THAN 12" BELOW STRUCTURAL SYSTEM. 4. JOINTS OF MEDIUM AND HIGH VELOCITY DUCT SYSTEMS SHALL BE SEALED WITH GASKETS OR LISTED MASTIC TYPE DUCT SEALANT. 5. DUCTS SHALL BE INSULATED AS INDICATED ON PLANS, PER 2012 WASHINGTON STATE ENERGY CODE, COMMERCIAL PROVISIONS DUCT WRAP, WHERE INDICATED, SHALL BE 11/2' 0.75 LB/CU FT FIBERGLASS DUCT INSULATION WITH A FACTORY APPLIED REINFORCED ALUM. FOIL VAPOR BARRIER (R-6 MIN.). - SOUND LINING, WHERE INDICATED, SHALL BE 1" 1.5 LB/CU FT FIBERGLASS DUCT LINING COATED TO PREVENT FIBER EROSION AT VELOCITIES UP TO 6000 FPM (R-6 MIN.). DUCT BOARD, WHERE INDICATED, SHALL BE 1" RIGID FRK FACED EI 475 FIBERGLASS DUCT BOARD SYSTEM, UL 181 LISTED AS A CLASS 1 AIR DUCT (R6 MIN.). AIR DUCT (R6 MIN) SUPPLY DUCT WHICH CONVEY SUPPLY AIR AT TEMPERATURES LESS THAN 55 DEG F OR GREATER THAN 105 DEG F SHALL BE INSULATED WITH A MINIMUM OF R-3.3, WHEN LOCATED IN CONDITIONED SPACE. 6. FLEX DUCTS SHALL CONSIST OF A REINFORCED VAPOR BARRIER, 11/2' FIBERGLASS INSULATION, AND NON -PERFORATED INTERIOR LINER WITH WIRE HELIX. DUCT SHALL BE A UL 181 LISTED CLASS 1 AIR DUCT. FLEX DUCTS SHALL ONLY BE USED WHERE SHOWN AND SHALL NOT EXCEED 12' IN LENGTH UNLESS NOTED OTHERWISE. 7. PROVIDE EARTHQUAKE RESTRAINT FOR HVAC EQUIPMENT IN ACCORDANCE WITH SECTION 1613 OF THE 2012 IBC. 8. PROVIDE FIRE DAMPERS, SMOKE DAMPERS AND FIREISMOKE DAMPERS WHERE INDICATED ON PLANS AND AS REQUIRED BY SECTION 717.5 OF THE 2012 IBC. PROVIDE CEILING FIRE DAMPERS WHERE INDICATED ON PLANS AND AS REQUIRED BY SECTION 717.6.2.1 OF THE 2012 IBC. INSTALL FIRE DAMPERS SMOKE DAMPERS AND FIRE/SMOKE DAMPERS IN ACCORDANCE WITH THE MANUFACTURERS INSTRUCTIONS, THE TERMS OF THEIR LISTING, AND THE REQUIREMENTS OF THE CODE. 9. PIPING PENETRATIONS OF FIRE RATED WALLS OR FLOORS SHALL BE SLEEVED AND FIRE STOPPED WITH LISTED MATERIALS SO AS TO MAINTAIN THE INTEGRITY AND RATING OF THE FLOOR OR WALL. 10. PROVIDE RETURN DUCT SMOKE DETECTOR AUTOMATIC SHUT DOWN OF ALL NEW HEATING, COOLING, OR VENTILATION EQUIPMENT MOVING IN EXCESS OF 2000 CFM IN ACCORDANCE WITH SECTION 606 OF THE 2012 IMC. POWER AND INTERLOCK WIRING WITH THE BUILDING FIRE ALARM SYSTEM IS BY THE ELECTRICAL CONTRACTOR. 11. HVAC EQUIPMENT, VALVES AND DAMPERS SHALL BE LOCATED IN EASILY ACCESSIBLE LOCATIONS. UNLESS SHOWN ON ARCHITECTURAL DRAWINGS, REQUIRED ACCESS PANELS SHALL BE PROVIDED AND INSTALLED BY THE GENERAL CONTRACTOR. MINIMUM ACCESS DOOR SIZE FOR VALVES AND DAMPERS TO BE 18"X 18". 12. HEAT TRACING OF PIPING, WHERE INDICATED, SHALL BE PROVIDED AND INSTALLED BY THE HVAC CONTRACTOR. THE HVAC CONTRACTOR IS TO COORDINATE THE HEAT TRACE POWER WIRING WITH ELECTRICAL CONTRACTOR. 13. MOTORS STARTERS NOT LISTED AS BEING PROVIDED IN THE HVAC EQUIPMENT SCHEDULES ARE TO BE PROVIDED AND INSTALLED BY ELECTRICAL CONTRACTOR. 14. WITHIN 90 DAYS AFTER THE DATE OF SYSTEM ACCEPTANCE, RECORD DRAWINGS OF THE ACTUAL INSTALLATION TO BE PROVIDED TO THE BUILDING OWNER. RECORD DRAWINGS SHALL INCLUDE AS A MINIMUM THE LOCATION AND PERFORMANCE DATA ON EACH PIECE OF EQUIPMENT, GENERAL CONFIGURATION OF DUCT AND PIPE DISTRIBUTION SYSTEM, INCLUDING SIZES, AND THE TERMINAL AIR AND WATER DESIGN FLOW RATES. 15. OPERATING AND MAINTENANCE MANUALS TO BE PROVIDED TO THE BUILDING OWNER THAT INCLUDE: SUBMITTAL DATA, NAMES AND ADDRESSES OF AT LEAST ONE SERVICE AGENCY, HVAC CONTROLS SYSTEM MAINTENANCE AND CALIBRATION INFORMATION AND A COMPLETE OPERATIONAL NARRATIVE FOR EACH SYSTEM. 16. COMMISSIONING IS REQUIRED ON THIS PROJECT IN ACCORD WITH WASHINGTON STATE ENERGY CODE (WSEC), COMMERCIAL PROVISIONS, SECTION C408 AND WITH LEED NC -2.1 FUNDAMENTAL BUILDING SYSTEMS COMMISSIONING AND ADDITIONAL COMMISSIONING. 17. A COMPLETE REPORT OF TEST PROCEDURES AND RESULTS SHALL BE PREPARED AND FILED WITH THE OWNER 18. FOR ALL "SEALED AIR TIGHT" SHAFTS OR ROOMS, THE FOLLOWING MUST OCCUR: - ALL VERTICAL JOINTS INSIDE THE SHAFT SHOULD BE PROVIDED WITH A CONTINUOUS SEAL FOR THE LENGTH OF THE JOINT, INCLUDING THE SHAFT CORNERS (BY GC). - TOP AND BOTTOM WALL TRACKS SHOULD BE CAULKED ALONG THEIR ENTIRE LENGTH (BY GC). - ANY FLOOR DECKING PERPENDICULAR TO THE SHAFT SHOULD BE CAULKED. FILLING WITH ROCK WOOL OR FIRESAFING ("MONOCOAT") IS NOT ACCEPTABLE (BY GC). - ANY PENETRATIONS OF THE SHAFT CONSTRUCTION (DUCTWORK, CONDUIT, PIPING) SHOULD BE SEALED WITH FIRE CAULKING ON BOTH SIDES OF THE PENETRATION. - USE SECTION 909.5 OF THE 2012 IBC FOR MAXIMUM ALLOWABLE LEAKAGE AREA, FOLLOWING THE GUIDELINES FOR SMOKE BARRIER CONSTRUCTION. - ALL DOORS MUST BE PROVIEDED WITH TIGHT FITTING GASKETS, AND OPEN AGAINST THE DIRECTION OF ROOM/SHAFT PRESSURE. 19. DAMPERS USED FOR OUTDOOR AIR INTAKE, EXHAUST, OR RELIEF SHALL HAVE THE FOLLOWING MAXIMUM LEAKAGE RATES AT 1" W.G. (PER AMCA STANDARD 500D): MOTORIZED DAMPERS: 4 CFM/S.F. GRAVITY DAMPERS: 20CFM/S.F. (40 CFM/S.F. FOR DAMPERS SMALLER THAN 24" IN EITHER DIMENSION). 20. OUTSIDE AIR INTAKE, EXHAUST, AND RELIEF DAMPERS SERVING CONDITIONED SPACES MUST BE MOTORIZED (FAIL CLOSED) PER WSEC, COMMERCIAL PROVISIONS, SECTION C402.4.5.2 AND 0403.2.4.4. EXCEPT AS ALLOWED BY WSEC. APN#:0004800015 �- LEGAL DESCRIPTION: LEWIS C C DC # 37 POR OF C C LEWIS DONATION CLAIM NO 37 TGW ! i�'R OF STEPHEN FOSTER DONATION CLAIM NO 38 IN SECTIONS 1n. 11, 14 & 15 TWP 23 RANGE 4 - BAAP BEARING N40 -01-05W 920.15FT FROM A MONUMENT AT PT OF INTSN OF CURVE ON C/L OF DUWAMISH- RENTON JUNCTION RD BEING APPROX 1000 FT E & 20 FT S OF QUARTER CORNER BETWEEN SECTIONS 14 & 15 TH N 49-24-00 W 835 FT ON A LINE PLT & 150 FT NELY OF C/L OF DUWAMISH-RENTON JUNCTION RD TAP BEARING N 81-44-5,5 E 199.17 FT FR POINT OF CURVE ON C/L OF DUWAMISH = RENTON JUNCTION RD SD PT OF CURVE BEING APPROX 1200 FT N & 440 FT W OF QUARTER CORNER BETWEEN SECTIONS 14 & 15 TH S 40-36-00 W 20 FT TO NELYMGN OF RNV OF PUGET SOUND ELECTRIC RAILWAY TH N 49-24-00 W 980.29 FT TH S 49-24-00 E 400 FT TH N 40-36-00 E 190 FT TO POB TH N 40-36-00 E 512.10 FT TH N 49-24-00 W 325 FT TH S 79-15-35 W 12.81 FT TH N 49-24-00 W 67 FT TH S 40-36-00 W 502.10 FT TAP BEARING N 49-24-00 W 400 FT FR POB TH S 49-24-00 E 400 FT TO POB - AICA LOT 2 OF CITY OF TUKWILA BDRY LINE ADJ NO 91-4-BLA RECORDING NO 9105231162 PLat Block: Plat Lot: POR jo Manges shall be made to the SaW Of mrk without prior ap2mvel of I -7711U ing Uivision. MOM: Revisions will require a nets plan submittal TITLE NAME COMPANY PHONE NUMBER EMAIL PROJECT ENGINEER TYLER VANDOOREN MACDONALD MILLER 206-768-3890 TYLER.VANDOOREN@MACMILLER.COM ACCOUNT MANAGER STEVE FLINK MACDONALD MILLER 253-680-3172 STEVE.FLINK@MACMILLER.COM SHEET METAL FOREMAN TIM FELTON MACDONALD MILLER 206-407-2692 TIM.FELTON@MACMILLER.COM AIR BALANCE FOREMAN RON LANDBERG MACDONALD MILLER 206-571-2661 RON.LANDBERG@MACMILLER.COM w Duwamish River Ike�0`i �t S o� G 599 q�e CO � Je' Q' LA Is, .17 LA -0 S E I o US 133rd St 5 0 NN'�1�1 MAP 5 3 Pi � ,�r,�td ^ ,i re`.°w16e subject to errors and omissions. PT0VF-1 0f -Ons 3 c ion documents does nol, alfii ionza V-19 Violai5.Ur y1 aily f:,1,d pted code or ordlnanca. Rec !A 01 aPPr0.^-C l=ie . Copy and conditionals ackno!adgad: S1.4 . Date: � City of Tukwila BUILDING DIVISION RECENED C I CITY �.y E TJrCWILA 'ERMIT CENTER L to (0 co Z H O 1- 00 co W ' Q W W C °I Z o W I00 O ,r N VJ O 0 coXOLL (D It a)M q 0 U)U- 0Z = 0Q C p c c� B C O 00 z, e QRZ �n 3 U j U_ °o N J Co W 75a- W� a s i �.-_- M �� �d W Q U < [D,J D to Z Z H O W D_ W W U °I Z o W I00 Q O 0 1 (D It V J U < [D,J D Z U H O W D_ m W U Z o O U) U < [D,J D Z U O W �- m U D I VJ (D V J 0Z O J m U 00 z, y U- �Q 0 W W W� a s i �.-_- M �� V/ r1� V� O I MM � _ Wr �/� VJ _ ENGINEER: LAST REVISED: T VAN DOOREN 04-08-16 CHECKED BY: DATE PLOTTED: B GEZON 04-08-16 CAD: ISSUE DAM R VILLANUEVA 04-08-16 DRAWING NUMBER: D-3756-73166234-00 SHEET NUMBER: TM10-01.1 m 3 0 0 M w tp n c m c La 1 04 0 m F v m m I rn rn v m 0 3 m 0 m M N co �O M n N M REVIEWED FOR CODE COMPLIANCE APPROVED MAY 0 5 2016 City of `€uila BUILDING DIVISION I'VE 'EIVED CITY OF TUKWILA PERMIT CENTER Lv Q l� (n Z U O I� r (n ~ Q 0 co I 1 (-01 U Q 0 ai T X U LL 0 U f U) p Q U) cu cc O O Q r 3 Z U o4 y Op 64 J cu cu < O N j m E p O ra Lv Q l� (n LvCL Z U � (n U j < I— D (n Z U O (n W �— I 1 (-01 U Q 0 D 0 (n LvCL Z U � (n U j < I— D Z U O W �— m U D C� U) 0 Z O J CU m oc ry LL W Q Lo Wo4 c/)D m ' � fi � U)r ENGINEER: LAST REVISED: T VAN DOOREN 04-08-16 CHECKED BY: DATE PLOTTED: B GEZON 04-08-16 CAD: ISSUE DATE: R VILLANUEVA 04-08-16 DRAWING NUMBER: D-3756-73166234-00 SHEET NUMBER: TM0.0-1-S- m N N O MOTHER'S ":Qom L215j j REVIEWED FOR CODE COMPLIANCE APPROVED MAY 0 5 2016 City of T&WIla BUILDING DIVISION RECEIVED CITY OF TUKWILA iz RMIT CENTER 1 1/8., = 1 --o-- I 6 Z 0 00 0 1 It 0 CD ce) 0 rl- co co ui f"'I 0) P.� < (o > ZNO 0) E U) O LL Y 0 U)U- " a) Q cu C) fu-') Wo < ' 0 ca 5, E 2 0 oco 0) (1) > C.0 (o o --p Z wQ o(DC) cu < C'4 a) < O 3! < == w o c/) 6 Z 0 00 0 1 It 0 z ui ry z oco (o o --p wQ ui < == w o c/) CF) D U) ENGINEER: LAST REVISED: T VAN DOOREN 04-08-16 CHECKED BY: DATE PLOTTED: B GEZON 04-08-16 CAD: ISSUE DAM - R VI LLAN U EVA 04-08-16 DRAWING NUMBER: D-3756-73166234-00 SHEET NUMBER: p q D 2.02 p p m I �1 N O0 N O NOTE: DEMO ALL EXISTING REZNOR UNITS MOTHER'S ROOM, L?i� REVIEWED FOR CODE COMPLIANCE APPROVED MAY 0 5 2016 City of Tukwila BUILDING DIVISION 0-'E I V E D CITY OF TUKWILA ;'ERMIT CENTER 11 L-5 V) 6i Z 0 0 U) D 0i (.0 cr) Q) z 0 rl- I- —00 i-. CD C3) ■ 77 < (0 F� � (0 pp do = 04 E U) 00 U 0 ILL -0 0 ca0 c/) CU E 0') U)< C) c: C13 'S (,D E C) a 0) a) C6 U) > Z 0 °o C14 to A < 0 r- a. L-5 V) 6i Z 0 0 U) D 0i Z z 0 U) Eli W pp 00 U 0 L-5 V) 6i Z 0 0 U) D z 0 W pp U ry 0') U) —j 00 F 0 00 LL < W Uj Lij L0 co U) c:) co 5 U) ENGINEER: LAST REVISED: T VAN DOOREN 04-08-16 CHECKED BY: DATE PLOTTED: B GEZON 04-08-16 CAD: ISSUE DATE.' R V1 LLAN U EVA 04-08-16 DRAWING NUMBER: D-3756-73166234-00 SHEEr NUMBER: It m a 0 IN N IqO O REVIEWED FOR C., ODE COMPLIANCE APPROVED MAY 0 5 2016 City Of Tuwla BUILDING DIVISION] '71, 7 " E I V&;:-: D CITY OF TUKWILA PERMIT CENTER 00 -5 1 1/8- = 1 '-0" 1 ri U) 6i w 0 0 V) 1 1 1 1 1 1 IQ Of &i (o Ce) z An C) I— — I— co (.0 Q ti ry < (o 1 0C)6 =60 c,4, E U) 2; 0 LL _0 q ca U) LL 0 i' co 0(.0 CCS LL. E C) < c: C:) E LLI MU) U) -.4- 0) co 0 ENGINEER: LAST REVISED: > < co z CHECKED BY: DATE PLOTTED: B GEZON 04-08-16 CAD: ISSUE DATE: to < VI LLAN U EVA 04-08-16 < DRAWING NUMBER: 0 SHEET NUMBER: 2.03 ri U) 6i w 0 0 V) 1 1 1 1 1 1 IQ Of &i z z 0 LLQ ry 00 0 1 ri U) 6i w 0 0 V) 1 1 1 1 1 1 IQ Of z LLQ ry z i' co 0(.0 o) CF) LL. ui LLI MU) U) co ENGINEER: LAST REVISED: T VAN DOOREN 04-08-16 CHECKED BY: DATE PLOTTED: B GEZON 04-08-16 CAD: ISSUE DATE: R VI LLAN U EVA 04-08-16 DRAWING NUMBER: D-3756-73166234-00 SHEET NUMBER: 2.03 �i NORTHWEST ELEVATION NO SCALE E 161'-7" 81'-lY2' v V 77'-6" 1 SOUTHWEST ELEVATION VIE NO SCALE CODE COMPLIANCE APPROVED'. - MAY 016 fi 0 5 2?1 CRY of Tukwil;a BUILDING DIVISION -IT"! OF TUKWILA 7- &J 3' 'ERMIT CENTER 005 1 1/8.1 = V-01, -1 6 Z 0 00 0 t� V) Elf W IL z 0 o 1 1 1 1 1 1 Ia of a (o co (D 0 00 C.0 0.) <o 60 ai IE. C24 IE U) co '— 0 LL —0 Co 0 cf) u- L-: (D U) r)z 00 < qr E 0) > cl) C) (D Z (.5 a) C\l cu <Q 00 0 (D 0 < coo I,- = Lu a. rl- 6 Z 0 00 0 t� V) Elf W IL z 0 o 1 1 1 1 1 1 Ia of a TM3.01 Z 0 LLJ ry CY) (D U) r)z 00 0 (D < coo LL Lu AD Lo a w c) c/) m o(D U) ENGINEER: LAST REVISED: T VAN DOOREN 04-08-16 CHECKED BY: DATE PLOTTED: B GEZON 04-08-16 CAD: ISSUE DATE- R VI LLAN U EVA 04-08-16 DRAWING NUMBER: D-3756-73166234-00 SHEET NUMBER: TM3.01