Loading...
HomeMy WebLinkAboutPermit M16-0054 - CORNER BAKERY - HOOK UP REFRIGERATION EQUIPMENT� FA- flolm m M 393 STRANDER BLVD M16-0054 City of Tukwila • Department of Community Development • 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-438-9350 Web site: http://www.TukwilaWA.gov Parcel No: 2623049064 Address: 393 STRANDER BLVD Project Name: CORNER BAKERY MECHANICAL PERMIT Permit Number: M16-0054 Issue Date: 4/21/2016 Permit Expires On: 10/18/2016 Owner: 2012 National Electrical Code: Name: REGENCY CENTERS LP 2012 Address: PO BOX 790830 C/O PROPERTY TAX International Mechanical Code Edition: 2012 DEPT, SAN ANTONIO, WA, 78279 2014 Contact Person: 2012 WA State Energy Code: Name: DAVE ZIGWEID Phone: (253) 625-1936 Address: 5009 PACIFIC HWY E, SUITE 9, FIFE, WA, 98424 Contractor: Name: GSC MECHANICAL LLC Phone: (360) 876-3700 Address: 5009 PACIFIC HWY EAST #9, FIFE, WA, 98424-3431 License No: GSCMEML907QS Expiration Date: 11/10/2016 Lender: Name: Address: DESCRIPTION OF WORK: HOOK UP REFRIGERATION EQUIPMENT Valuation of Work: $8,690.00 Type of Work: NEW Fuel type: Fees Collected: $311.22 Electrical Service Provided by: PUGET SOUND ENERGY Water District: TUKWILA Sewer District: TUKWILA SEWER SERVICE Current Codes adopted by the City of Tukwila: International Building Code Edition: 2012 National Electrical Code: 2014 International Residential Code Edition: 2012 WA Cities Electrical Code: 2014 International Mechanical Code Edition: 2012 WAC 296-466: 2014 Uniform Plumbing Code Edition: 2012 WA State Energy Code: 2012 International Fuel Gas Code: 2012 Permit Center Authorized Signature: rlkwt& Pft Date: (�/ / I hearby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this development permit and agree to the conditions attached to this permit. Signa Print Date: L — ) r -/, This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: Work shall be installed in accordance with the approved construction documents, and any changes made during construction that are not in accordance with the approved construction documents shall be resubmitted for approval. 2: All permits, inspection record card and approved construction documents shall be kept at the site of work and shall be open to inspection by the Building Inspector until final inspection approval is granted. 3: All construction shall be done in conformance with the Washington State Building Code and the Washington State Energy Code. 4: There shall be no occupancy of a building until final inspection has been completed and approved by Tukwila building inspector. No exception. 5: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of this requirement. 6: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206-431-3670). 7: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center. 8: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 9: `MECHANICAL PERMIT CONDITIONS' 10: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431-3670). 11: Manufacturers installation instructions shall be available on the job site at the time of inspection. 15: The attached set of mechanical plans have been reviewed by The Tukwila Fire Marshals Office and are acceptable with the following concerns: 14: Fire protection systems shall be maintained in accordance with the original installation standards for that system. Required systems shall be extended, altered or augmented as necessary to maintain and continue protection whenever the building is altered, remodeled or added to. Alterations to fire protection systems shall be done in accordance with applicable standards. (IFC 901.4) (EXTEND SPRINKLER PROTECTION TO WALK-IN COOLER.) 12: All new sprinkler systems and all modifications to existing sprinkler systems shall have fire department review and approval of drawings prior to installation or modification. New sprinkler systems and all modifications to sprinkler systems involving more than 50 heads shall have the written approval of Factory Mutual or any fire protection engineer licensed by the State of Washington and approved by the Fire Marshal prior to submittal to the Tukwila Fire Prevention Bureau. No sprinkler work shall commence without approved drawings. (City Ordinance No. 2436). 13: Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (City Ordinances #2436 and #2437) 16: Any overlooked hazardous condition and/or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. 17: These plans were reviewed by Inspector 511. If you have any questions, please call Tukwila Fire Prevention Bureau at (206)575-4407. PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 1400 FIRE FINAL 0703 MECH EQUIP EFF 1800 MECHANICAL FINAL 0609 PIPE/DUCT INSULATION 0705 REFRIGERATION EQUIP 0701 ROUGH -IN MECHANICAL CITY OF TUMVILA Commmil(t' Uel-clopmerrl Deparbnerll Pet mil Cottle) �{ W0 Soulhcente) BA -d., Sidle 100 TiAmila, 11W 98188 ` Ittlp:/Ae>.+,�v.T'ukwilall'A.gnv Mechtntical Permit No... Project No. Date Application Accepted: Dale Application Expires: __ -MECHANICAL PERMIT APPLICATION - -- - - - ___ Applications and plans must be complete in order to be acceplf-A far 1)11111 review Applications will not be accepted through ilia mail or by fox. **please print*" SITE LOCATION Tang Co Assessor's Tax No.: ;A" -,>)d LV\Q Site Address: Will 19reaW00L 6",q. 98M Suite Number: 2" floor: 'I'ennnt NumeL40ILH t SA14494 CWRE New Tennul: AK ..... Yes []..No PROPERTY OWNER Nanta ws, Soler amum ``Cbts Address: 00mis Cily: State: Zi t: CONTACT PERSON — person rccciving all project communication Name: CsaK6Q � F Address: City: Slow Zi), Y.I�+ Phone: Fax: G"— S9 `— 8"" Email: MECHANICAL CONTRACI'Olt INFORMATION Company Nnute: Address: Sri vLlc� ec rC S,< 1 City: ,Z ; SUNe� Zipp%% Phone: a93 -`s 5�t'nx: �63-�1`6'Sp�� Cont) Reg No.: CCGS��E�L`1� ?rate: ` O VS Tukwiln Busiucss License No.:e�S_� � a V:duatian of project (contractor's bid price): A � G (311) I)curibc the: scope of work in detail: (` , O0k '�`.p �� �S c -SCS a i� z: c�" vxl ZA- um Residential: New.... ...... ❑ Replacement ........ ❑ Commercial: New .......... 29 Replaccnicnt........ ❑ fuel Type: Electric..... ❑ Gas....... ❑ Olher:,� ?+ r4 Seat' UAAMitsAmt4wmt•AMli4ti3uOnUmQ016AMb.mmt 1rcfw"Pe1w1Ap*jto itt%jmd14.1&an% R1,60 1WuyJW1F pirc 1;512 bb I Itidicnic type of meclinnicnl mark being installed and lite quantity below: Unit Type Qly Fumace <100k but Residential, Nighttime Fumacc>1001; btu Industrial Floor funince 55 dB(A) Suspended/wall/floor mounted heater 57 dB(A) Ae2fiance vent Commercial Repair or ndditinn to hent/refrig/cooling s •stein 47 dB(A) Air handling tacit <10,0000,111 65 dl3(A) Unit Type Qty Air handling unit >10,000 cfin Residential, Nighttime Evapomfor cooler Industrial Ventilation fnit connected to single duct 55 dB(A) Ventilation syslent 57 dB(A) Hood slid duct Commercial Incinerator— domestic 47 dB(A) hlcinerator— conmt/industrial 65 dl3(A) thtit'fype Qty Fire damper Diffuser T hennosint Wood/gas slow Finergency generator Othcr tnechanical equipment Boiler/Compressor I Qty 0.3 lip/100.000 btu 3-15 lip/500,000 No 15.30 hp/1,000,000 bur 30.501tit/1,750,000 bin 50t hn/1.750.000 bol Noise: Mechanical units need to be in compliance with the Tukwila poise Code. Maximum permissible sound levels are based nil fmnl where lite sound is cleated and where the sound is heard. Additionally, if suintd can be heard from within it house nt night in a residential xonc it may not be allowed. For more deluils, see TRIC 8.22 District of Sound Producing Source District of Receiving; Property Residential, Da bate' Residential, Nighttime Commercial Industrial Residential 55 dB(A) 45 dB(A) 57 dB(A) 60 dB(A) Commercial 57 dB(A) 47 dB(A) 60 dB(A) 65 dl3(A) industrial 60 dB(A) 50 dB(A) 65 dl3(A) 70 dB(A) 's Daytime means 7A A-1-I0111M, Monday through Friday and 8AM-I OPM, Saturday, Sunday atxl Slate -recognized holidays. A fem sounds me exempt fiom the noise ciuk, including - Wal lling ncluding:Wal'lling devices; Cmtstnaclirnt ami Imlicny innintemnce during the daytime hulas (7am-1 Opm); Testing of hacknp gencrntors during the day. PERNI IT APPLicivi-ION NOTES - \'iliac of Colist ruelill in nil eases, it %alae of cunstnlcliom unnnun should lie entered by lite upplieanl. 'I his ligure will lie re%ie%%vd mud is subject ler Iwssiblc rct ision by lite Itermil tatter to comply with titrant fee schedules. tNjilratiun of plon revicir— npplicntions for which no liennit is issued within l80 da)s fiillowing the date of uppliention shnll expire by Iin, itmion, he building ollicial may grail one cmensinn of tiutc for additional periads not to exceed 00 days each. The extension shall be requested in uriliog and justifiable cause dc'nlnnSIM(M. Section 105.3.2 towmatiolnd Building Code (current edition). i IIFRFDY +CizRTIfY 'fl-IA`r i I [AV[-' READ AND CXAMINCD I HIS APPLiCA110N AND KNOW TI IF SAME TO HE I RIJI'. UNDIM I3iiNAUI'Y OP PI-RJURY 13Y THE' LAWS OF TI IF. STATE OF NASi IINGT•ON, AND I AM AUTI IORIZGD TO APPLY FOI( TI IIS PMMIT. BUILDING OWNER OR AUTHORIZED', Signature• ��,\ Date• '`� " � � �,� Print Nnme: �•�-`Q-1 U Day Tclephonca.s,\C� k� l City State Zip 1t.Mn.lilsiar'rartu-ArJKiliau an 1 MiSet i Ar'iii31i001 Wcb3ntG11'ulna A�ticiliva Aa�utJ 1 a-Ibdm Rai, t fan s,Zlsip--- bj;e"Of2 bb DESCRIPTIONS PermitTRAK ACCOUNT QUANTITY PAID $311.22 M16-0054 Address: 393 STRANDER BLVD Apn: 2623049064 $311.22 MECHANICAL $299.25 PERMIT ISSUANCE BASE FEE R000.322.100.00.00 0.00 $32.50 PERMIT FEE R000.322.100.00.00 0.00 $206.90 PLAN CHECK FEE R000.322.102.00.00 0.00 $59.85 TECHNOLOGY FEE $11.97 TECHNOLOGY FEE TOTAL FEES PAID BY RECEIPT: .. 179 R000.322.900.04.00 0.00 $11.97 $311.22 Date Paid: Tuesday, April 12, 2016 Paid By: DAVE ZIGWEID Pay Method: CREDIT CARD 066259 Printed: Tuesday, April 12, 2016 2:06 PM 1 of 1 r1q� J SY57EM5 INSPECTION RE F) Retain a copy with NSPECTION NO. CITY OF TUKWILA BUIL 6300 Southcenter Blvd., #100, Tukwila. WA CORD r1 permit f�' Odr I PERMIT NO. DING DIVISION 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project: covk Ty/p(�of Inspection; ( f Address: J ��r 3 �(V / d Date Called: Special Instructions: Date W nted: �f a.m. p.m. Requester: "— Phone No: Inspector: Lc� Dater /_� ` I L- `� REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Catl to schedule reinspection. t(-." I INSPECTION RECORD Retain a copy with permit Oar - I SPECTION N0. PERMIT N0. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Prgject: i�I Type-qf Inspection` )ddress: / Date Called: Special Instructions: Date W nted: _ l a.m. p.m. iRequest&:. Phone No: Inspector: � Date: REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. UNI-PAK REMOTE REFRIGERATION SYSTEM 1/21/2016 for Outdoor Applications Corner Bakery_Seattle Wa_ WEIGHT OF CONDENSING UNITS 347 # Corner Bakery WEIGHT OF EVAPORATOR COILS 0 # Seattle Wa 16-0083 O = OFF -CYCLE DEFROST E" = DEFROST CLOCK BY FIXTURE MANUFACTURER ALL COMPRESSORS AND CONDENSER CIRCUITS ARE SIZED TO OPERATE AT 95' F AMBIENT EACH SYSTEM SUPPLIED WITH MOUNTED LIQUID LINE FILTER DRIER, SIGHT -GLASS EACH SYSTEM SUPPLIED WITH SUCTION LINE KIT INCLUDING A SUCTION LINE FILTER AND PIPING FACTORY INSTALLED ,ibWaF A division of the Heat Transfer Products Group LLC. 8101 E Kaiser Blvd. #110 - Anaheim, California 92808 - (800) 772-2653 office - (714) 529-8503 facsimile M I - C)05H REVIEWED FOR DDEC01UPLIANCE -- V APR 1.9 2016 City bf Tukt�ii� BOLgING DIVISION RECEIVED CITY OF TUKWILA APR 12 2016 PERMIT CENTER FIXTURES CONDENSING UNITS COLDZONE EVAPORATOR COILS PIPING TEMP. FAN MOTORS DEFROST I R H S T T E O y I E F R A C Q A A S M M F S R S M V A D U M V M V T S E S I U I E P O P E A P O P O E U L Y N X C G M P E L A F N M E L E L M C I C S U T T E O O R T C R T O R T R T T Q L T B U I A D W A / 1 O 1 D A / A / M I U O E E R O N E E G P T S T E G P G P P O 1 C M R DESCRIPTION E N T I L I R E-1 H I Y T Y L E H E I H s N D K A MULTIPLEXED LOADS DELFIELD COLD PAN DELFIELD BASE DELFIELD COLD PAN DELFIELD BASE 35 20 R -404A 0R-H125M44-2T 1.3 7.4 208/3 Al 503 503 508 508 VERIFY VERIFY VERIFY VERIFY SUPPLIED BY OTHERS A2 SUPPLIED BY OTHERS A3 SUPPLIED BY OTHERS A4 SUPPLIED BY OTHERS B MULTIPLEXED LOADS DELFIELD BASE DELFIELD COLD PAN DELFIELD BASE 35 20 R -404A OR-H055M44-2S 0.5 6.1 208/1 5.6 E" 6.1 5/8 3/8 B1 512A 512C 523A VERIFY SUPPLIED BY OTHERS B2 VERIFY SUPPLIED BY OTHERS B3 VERIFY SUPPLIED BY OTHERS O = OFF -CYCLE DEFROST E" = DEFROST CLOCK BY FIXTURE MANUFACTURER ALL COMPRESSORS AND CONDENSER CIRCUITS ARE SIZED TO OPERATE AT 95' F AMBIENT EACH SYSTEM SUPPLIED WITH MOUNTED LIQUID LINE FILTER DRIER, SIGHT -GLASS EACH SYSTEM SUPPLIED WITH SUCTION LINE KIT INCLUDING A SUCTION LINE FILTER AND PIPING FACTORY INSTALLED ,ibWaF A division of the Heat Transfer Products Group LLC. 8101 E Kaiser Blvd. #110 - Anaheim, California 92808 - (800) 772-2653 office - (714) 529-8503 facsimile M I - C)05H REVIEWED FOR DDEC01UPLIANCE -- V APR 1.9 2016 City bf Tukt�ii� BOLgING DIVISION RECEIVED CITY OF TUKWILA APR 12 2016 PERMIT CENTER PERMIT GQORR COPY PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: M16-0054 DATE: 04/12/16 PROJECT NAME: CORNER BAKERY SITE ADDRESS: 393 STRANDER BLVD X Original Plan Submittal Response to Correction Letter # Revision # before Permit Issued Revision # after Permit Issued DEPARTMENTS: AT AWC 4-144P Building Division 11 Fire Prevention Planning Division ❑ Public Works ❑ Structural ❑ Permit Coordinator PRELIMINARY REVIEW: DATE: 04/14/16 Not Applicable ❑ Structural Review Required ❑ (no approval/review required) REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: DUE DATE: 05/12/16 Approved ❑ Approved with Conditions Corrections Required ❑ (corrections entered in Reviews) Notation: REVIEWER'S INITIALS: Denied ❑ (ie: Zoning Issues) DATE: Perinit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: 12/18/2013 GSC MECHANICAL LLC Home Espanol Contact Safety & Health Washington State Department of Labor & Industries GSC MECHANICAL LLC Owner or tradesperson Principals HUNTINGTON, BETTY, PARTNER/MEMBER Doing business as GSC MECHANICAL LLC WA UBI No. 603 033 088 License Page 1 of 2 A -"L Index Heli} M.V l.&I Claims & Insurance Workplace Rights Trades & Licensing 5009 Pacific Highway East #9 TACOMA, WA 98424 253-235-5692 PIERCE County Business type Limited Liability Company Verify the contractor's active registration / license / certification (depending on trade) and any past violations. Construction Contractor .............._.._......._. Active. Meets current requirements. License specialties GENERAL License no. GSCMEML9070S Effective — expiration 11/10/2010-11/10/2016 Bond ................. WESTCHESTER FIRE INSURANCE COMPANY $12,000.00 Bond account no. K07940427 Received by L&I Effective date 11/10/2010 11/05/2010 Expiration date Until Canceled Insurance Evanston Ins Co $1,000,000.00 Policy no. 15PKGWE00225 Received by L&I Effective date 09/29/2015 09/30/2015 Expiration date 09/30/2016 Insurance history Savings No savings accounts during the previous 6 year period. Lawsuits against the bond or savings No'lawsuts against the bond or savings accounts during the previous 6 year period. LSI Tax debts No LM tax debts are recorded for this contractor license during the previous 6 year period, but some debts may be recorded by other agencies. License Violations No license violations during the previous 6 year period. https:Hsecure.Ini.wa.gov/verify/Detail.aspx?UBI=603033088&LIC=GSCMEML907QS&SAW= 4/22/2016 IM.'N ME 32.00 119.00 REF'G LINES REF'G LINES BY OTHERS RUN REF'G LINES BY OTHERS 19.00 CLEAR -}-13.00 S/S APRON [TO THIS LOCATION FOR SKU TO WALL I 000-201 YDGX4 To THIS LO Th FOR SKU 000-201 GX5 _ 32.00 I I I I I I I I IFilI Tull I I I I I I I I I I I I I I I d I I� Im m m m CD m GD m ItIE'CHANICAL DETAIL RUN REF'G UNES TO THIS LO,J�ATION FOR SKU_# 000-201YDGX6 119.00 REF'G LINES BY OTHERS 155.00 84.00 71.00 40.00 27.00 44.00 6.00 --- 6.00 38.00 PROVIDE PAN TEMPLATE TO 5p3 HOLD PANS AS SHOWN S/S � END �rr RUN REF'G LINES TO THIS LOCATION FOR SKU 000-201 GX3 02.00 02.00 SKU NO. 000-201YDGX3 MODEL NO, ISHR44R I ITEM NO. 503 -REMOTE MEGA TOP WORK TABLE -(26) 1/6 SIZE PANS 6' DEEP BY OTHERS (SEE TOP VIEW FOR PAN LAYOUT) -PROVIDE (2) 15' X 25.751 ADAPTOR BARS AND (1) 1' X 35' ADAPTOR BAR -1.50' DIA. HOLE FOR ACCESS TO POWER SWITCH IN PANEL -337-417 STORAGE IN TOP OPENINGCS) -36'F-40'F STORAGE IN BASE -COLD PAN BTU'S = 1617 -BASE BTU'S = 444 -115V-2DA -REF'G PACKAGE, R -404A -BASE PROVIDED WITH EXPANSION VALVE, SOLENOID VALVE, AND THERMOSTATIC CONTROL -RAIL PROVIDED WITH EXPANSION VALVE, THERMOSTATIC CONTROL, AND SOLENOID VALVE WITH ON/DFF SWITCH -ELECTRIC CONDENSATE EVAPORATOR C115V-1.74A) MODEL NO. 16DS40 -OPEN SHELF UTILITY STAND -ADJUSTABLE HEIGHT CENTER SHELVES -EXTEND COLD PAN OVER THIS SECTION WITH PLATE SHELF BELOW -1' BACKSPLASH AT REAR SKU NO. 000-201YDGX4 MODEL NO. 160S27 I ITEM NO. 508 -OPEN SHELF UTILITY STAND -ADJUSTABLE HEIGHT CENTER SHELVES -EXTEND COLD PAN OVER THIS SECTION WITH PLATE SHELF BELOW MODEL NO. 16MR44L -REMOTE MEGA TOP WORK TABLE -(26) 1/6 SIZE PANS 6' DEEP BY OTHERS (SEE TOP VIEW FOR PAN LAYOUT) -PROVIDE (2) 15' X 25.75' ADAPTOR BARS AND a) I' X 28' ADAPTOR BAR -1.50' DIA. HOLE FOR ACCESS TO POWER SWITCH IN PANEL -33F -41'F STORAGE IN TOP OPENING(S) -36•F-40•F STORAGE IN BASE -COLD PAN BTU'S = 1617 -BASE BTU'S = 444 -115V-3.04 -REF'G PACKAGE, R -404A -BASE PROVIDED WITH EXPANSION VALVE, SOLENDID VALVE, AND THERMOSTATIC CONTROL -RAIL PROVIDED WITH EXPANSION VALVE, THERMOSTATIC CONTROL, AND SOLENOID VALVE WITH ON/OFF SWITCH -PROVIDE CUSTOM ADAPTER PLATE IN 1/6 SIZE PAN FOR BOTTLES Provide (8) 10-5/8" dia. -ELECTRIC CONDENSATE EVAPORATOR cutouts 13" on center (115V -1,74A) for Vollrath 74701D Drop-in. Induction warmers. I I I I I I I I 101 I I I I I I I 33.00 MECHANICAL LEGEND # R = REFRIGERATION LINES, 1/4' LIQUID, 3/8' SUCTION ♦ G = GAS C13NNECTIDN ♦ D = DRAIN OUTLET ♦ HC = HOT OR COLD WATER CONNECTION ♦ H = HOT WATER CONNECTION ♦ C = COLD WATER CONNECTION F < = BREAKER PANEL BOX 6' A.F.F. MINIMUM M =JUNCTION BOX rr=====I J =JUNCTION BOX AND 8'-O' CORD AND PLUG J = CONDENSING UNIT WIRED TO J -BOX, J -BOX WIRED TO ON/OFF SWITCH AND 8'-O' CORD AND PLUG n 7 301 3 MODEL NO. SMRRZ1-S 11TEM NO. 301 -SELF CONTAINED S/S DOOR REF'G ROLL -IN SINGLE SECTION UNIT -CU FULL HEIGHT S/S DOORS -(2) HINGES PER DOOR -ALUMINUM EXTERIOR -ALUMINUM INTERIOR -HEAVY DUTY PILASTER/CLIPS -DIGITAL THERMOMETER -TOP MOUNT, TXV REF'G PACKAGE (R-404A) -115V-60C-IPH-6.8A-1/4 H.P. (NEMA 5-15P) -HEAVY DUTY 12 GAUGE S/S SYSTEM. -SELF LUBRICATED DELRIN TRIAD MARK ROLLERS ELIMINATE METAL TO METAL CONTACT, NO CORROSION, NO RUST, AND NO MESSY GREASE TO DEAL WITH. -PARALLEL TRACK CONTROL WITH DELFIEL.D'S EXCLUSIVE BINARY ROLLER SYSTEM. -FULL EXTENSION PLUS ALLOWS PANS TO LIFT STRAIGHT OUT. -EASY GRIP PAN FLANGE. -TRACKS SNAP OUT FOR EASY DISHWASHER CLEANING. -STAY SHUT FEATURE. -PANS BY OTHERS. -DRAWERS SIZED TO ACCEPT PANS AS SHOWN. -LOW PROFILE AND 3 HI DRAWERS ACCEPT 4" DEEP PANS, ALL OTHERS ACCEPT UP TO 6" DEEP PANS AS STANDARD. 12" X 20" PAN B/0 MODEL NO, 16SD48 = °' S/S APRON PLATE SHELF PLATE SHELF S/S APRON (115V -1.74A) 111.00 19E° R F'G )RAWER R L� 19" REF'G 19 REF'G DOOR R404A R404) 0 ® 112.00 12 X 20" PAN B/0 0 ® G� G� 19" REF'G 19" REF' DOOR R404A DOOR R40)RAWER ADJUSTABLE SHELF ADJUSTABLE SHELF -ADAPTER BARS BY OTHERS < .a o J o 0:) OPEN SHELF OPEN SHELF 6.00 33.00 I j y< POWER SWITCH IN PANEL FD -33F -41'F STORAGE IN TOP OPENING(S) y CID -36•F-40'F STORAGE IN BASE E --I SKU NO. 000-201YDGX3 MODEL NO, ISHR44R I ITEM NO. 503 -REMOTE MEGA TOP WORK TABLE -(26) 1/6 SIZE PANS 6' DEEP BY OTHERS (SEE TOP VIEW FOR PAN LAYOUT) -PROVIDE (2) 15' X 25.751 ADAPTOR BARS AND (1) 1' X 35' ADAPTOR BAR -1.50' DIA. HOLE FOR ACCESS TO POWER SWITCH IN PANEL -337-417 STORAGE IN TOP OPENINGCS) -36'F-40'F STORAGE IN BASE -COLD PAN BTU'S = 1617 -BASE BTU'S = 444 -115V-2DA -REF'G PACKAGE, R -404A -BASE PROVIDED WITH EXPANSION VALVE, SOLENOID VALVE, AND THERMOSTATIC CONTROL -RAIL PROVIDED WITH EXPANSION VALVE, THERMOSTATIC CONTROL, AND SOLENOID VALVE WITH ON/DFF SWITCH -ELECTRIC CONDENSATE EVAPORATOR C115V-1.74A) MODEL NO. 16DS40 -OPEN SHELF UTILITY STAND -ADJUSTABLE HEIGHT CENTER SHELVES -EXTEND COLD PAN OVER THIS SECTION WITH PLATE SHELF BELOW -1' BACKSPLASH AT REAR SKU NO. 000-201YDGX4 MODEL NO. 160S27 I ITEM NO. 508 -OPEN SHELF UTILITY STAND -ADJUSTABLE HEIGHT CENTER SHELVES -EXTEND COLD PAN OVER THIS SECTION WITH PLATE SHELF BELOW MODEL NO. 16MR44L -REMOTE MEGA TOP WORK TABLE -(26) 1/6 SIZE PANS 6' DEEP BY OTHERS (SEE TOP VIEW FOR PAN LAYOUT) -PROVIDE (2) 15' X 25.75' ADAPTOR BARS AND a) I' X 28' ADAPTOR BAR -1.50' DIA. HOLE FOR ACCESS TO POWER SWITCH IN PANEL -33F -41'F STORAGE IN TOP OPENING(S) -36•F-40•F STORAGE IN BASE -COLD PAN BTU'S = 1617 -BASE BTU'S = 444 -115V-3.04 -REF'G PACKAGE, R -404A -BASE PROVIDED WITH EXPANSION VALVE, SOLENDID VALVE, AND THERMOSTATIC CONTROL -RAIL PROVIDED WITH EXPANSION VALVE, THERMOSTATIC CONTROL, AND SOLENOID VALVE WITH ON/OFF SWITCH -PROVIDE CUSTOM ADAPTER PLATE IN 1/6 SIZE PAN FOR BOTTLES Provide (8) 10-5/8" dia. -ELECTRIC CONDENSATE EVAPORATOR cutouts 13" on center (115V -1,74A) for Vollrath 74701D Drop-in. Induction warmers. I I I I I I I I 101 I I I I I I I 33.00 MECHANICAL LEGEND # R = REFRIGERATION LINES, 1/4' LIQUID, 3/8' SUCTION ♦ G = GAS C13NNECTIDN ♦ D = DRAIN OUTLET ♦ HC = HOT OR COLD WATER CONNECTION ♦ H = HOT WATER CONNECTION ♦ C = COLD WATER CONNECTION F < = BREAKER PANEL BOX 6' A.F.F. MINIMUM M =JUNCTION BOX rr=====I J =JUNCTION BOX AND 8'-O' CORD AND PLUG J = CONDENSING UNIT WIRED TO J -BOX, J -BOX WIRED TO ON/OFF SWITCH AND 8'-O' CORD AND PLUG n 7 301 3 MODEL NO. SMRRZ1-S 11TEM NO. 301 -SELF CONTAINED S/S DOOR REF'G ROLL -IN SINGLE SECTION UNIT -CU FULL HEIGHT S/S DOORS -(2) HINGES PER DOOR -ALUMINUM EXTERIOR -ALUMINUM INTERIOR -HEAVY DUTY PILASTER/CLIPS -DIGITAL THERMOMETER -TOP MOUNT, TXV REF'G PACKAGE (R-404A) -115V-60C-IPH-6.8A-1/4 H.P. (NEMA 5-15P) -HEAVY DUTY 12 GAUGE S/S SYSTEM. -SELF LUBRICATED DELRIN TRIAD MARK ROLLERS ELIMINATE METAL TO METAL CONTACT, NO CORROSION, NO RUST, AND NO MESSY GREASE TO DEAL WITH. -PARALLEL TRACK CONTROL WITH DELFIEL.D'S EXCLUSIVE BINARY ROLLER SYSTEM. -FULL EXTENSION PLUS ALLOWS PANS TO LIFT STRAIGHT OUT. -EASY GRIP PAN FLANGE. -TRACKS SNAP OUT FOR EASY DISHWASHER CLEANING. -STAY SHUT FEATURE. -PANS BY OTHERS. -DRAWERS SIZED TO ACCEPT PANS AS SHOWN. -LOW PROFILE AND 3 HI DRAWERS ACCEPT 4" DEEP PANS, ALL OTHERS ACCEPT UP TO 6" DEEP PANS AS STANDARD. 32" DRAWER 27" DRAWER 24" DRAWER 19" DRAWER TOP VIEW TOP VIEW TOP VIEW TOP VIEW f-- Mirror line up 12" X 20" PAN B/0 MODEL NO, 16SD48 = °' -SLIDING DOOR UTILITY STAND -REMOVABLE OVAL TRAY STORAGE -ELECTRIC CONDENSATE EVAPORATOR RACKS. -VERIFY TRAY SIZE (115V -1.74A) 111.00 MODEL NO,ISRR39R 39.00 112.00 12 X 20" PAN B/0 O -- 27" REF'G DOOR R404A XCa N 4 rn 24.00 88.00 X0] 32" DRAWER 27" DRAWER 24" DRAWER 19" DRAWER TOP VIEW TOP VIEW TOP VIEW TOP VIEW f-- Mirror line up S/S�END 512A 51�1i r / Do not provide hot wells -- ENp SSS PARTIAL EENND 262.00 MODEL NO, 16SD48 -OVAL TRAY STORAGE CABINET -SLIDING DOOR UTILITY STAND -REMOVABLE OVAL TRAY STORAGE -ELECTRIC CONDENSATE EVAPORATOR RACKS. -VERIFY TRAY SIZE (115V -1.74A) 111.00 MODEL NO,ISRR39R 39.00 112.00 W O -- 27" REF'G DOOR R404A 31.50 24.00 88.00 24.00 39.00 48.00 -ADAPTER BARS BY OTHERS < .a o J o 0:) 33.00 6.00 E-' 6.00 33.00 I j y< POWER SWITCH IN PANEL FD -33F -41'F STORAGE IN TOP OPENING(S) y CID -36•F-40'F STORAGE IN BASE E --I -RAIL BTU'S = 180 S/S END I I oo I 0 0 0 0 0 0 c 0- c� -REF'G PACKAGE, R -404A -1��� 1 JIL AL -BASE PROVIDED WITH EXPANSION VALVE, ¢ x SOLENOID VALVE, AND THERMOSTATIC CONTROL 25.50 THERMOSTATIC CONTROL, AND SLILENDID 11.50 S/S I I I r I PERMIT CENTER I I I I I I I I I 31.51 44.00XaOOXQ50 r_1 e0NPDSNE rebWT7WhBOARD r -r 44.QOXa�XaSo COMOSITE VU IVIG BOARD END �I W CD LJ LJ LJ LJ LJ LJ LJ LJ z IM X co zco 6.00 z a O I I S/S�END 512A 51�1i r / Do not provide hot wells -- ENp SSS PARTIAL EENND 512A SKU NO. 000-201YDGX5 MODEL NO. 18WR39R ITEM U. 512A -REMOTE REF'G WORK TABLE -(U SHELF PER DOOR SECTION -36•F -40•F STORAGE -BASE BTU'S = 465 -115V -3.0A -REF'G PACKAGE, R -404A -BASE PROVIDED WITH EXPANSION VALVE, SOLENOID VALVE, AND THERMOSTATIC CONTROL -ELECTRIC CONDENSATE EVAPORATOR (115V -1,74A) 512B SKU NO. 000-201YDGX6 MODEL NO. 16HD24 I ITEM NO. 512B -HINGED DOOR UTILITY STAND -PROVIDE WITH AUTO FILL ASSEMBLY MODEL NO. 2OSS88 -TOP EXTENSION WITH S/S SIDES -SLIDING D= -INSTALL (5) WELLS SS -811 FOOD AND LIQUID WARMERS WITH DRAINS AND MANIFOLD (12OV-3.8A EACH) -INSTALL (3) WELLS HW106D FOOD AND LIQUID WARMERS WITH DRAINS AND MANIFOLD (12OV-3.84 EACH) -THIS SECTION TO BE SHALLOW DEPTH Provide (8) 5"x2-5/8" cutouts for Vollrath 74701D Control Box Mounting 512C SKU NO, 000-201YDGX7 MODEL NO 21 1 ITEM NO. 512C MODEL NO, 16SD48 -OVAL TRAY STORAGE CABINET -SLIDING DOOR UTILITY STAND -REMOVABLE OVAL TRAY STORAGE -ELECTRIC CONDENSATE EVAPORATOR RACKS. -VERIFY TRAY SIZE (115V -1.74A) 30.9 MODEL NO,ISRR39R -REMOTE REF'G REDUCED RAIL WORK TABLE W O -- 27" REF'G DOOR R404A 31.50 O I 11 I I I I S/S I I I I I I I I I I I I APRON I I I I 1 L - -0-A == AWL ----- _ A = A_=w I 24' DRY I O SLIDING SLIDING O I DDLIR I - - - . ® END -ADAPTER BARS BY OTHERS < .a o J o 0:) ® E-' 0 000" RE OG SLIDING SLIDING R R4 441 I j y< POWER SWITCH IN PANEL FD -33F -41'F STORAGE IN TOP OPENING(S) y CID -36•F-40'F STORAGE IN BASE 512A SKU NO. 000-201YDGX5 MODEL NO. 18WR39R ITEM U. 512A -REMOTE REF'G WORK TABLE -(U SHELF PER DOOR SECTION -36•F -40•F STORAGE -BASE BTU'S = 465 -115V -3.0A -REF'G PACKAGE, R -404A -BASE PROVIDED WITH EXPANSION VALVE, SOLENOID VALVE, AND THERMOSTATIC CONTROL -ELECTRIC CONDENSATE EVAPORATOR (115V -1,74A) 512B SKU NO. 000-201YDGX6 MODEL NO. 16HD24 I ITEM NO. 512B -HINGED DOOR UTILITY STAND -PROVIDE WITH AUTO FILL ASSEMBLY MODEL NO. 2OSS88 -TOP EXTENSION WITH S/S SIDES -SLIDING D= -INSTALL (5) WELLS SS -811 FOOD AND LIQUID WARMERS WITH DRAINS AND MANIFOLD (12OV-3.8A EACH) -INSTALL (3) WELLS HW106D FOOD AND LIQUID WARMERS WITH DRAINS AND MANIFOLD (12OV-3.84 EACH) -THIS SECTION TO BE SHALLOW DEPTH Provide (8) 5"x2-5/8" cutouts for Vollrath 74701D Control Box Mounting 512C SKU NO, 000-201YDGX7 MODEL NO 21 1 ITEM NO. 512C MODEL NO, 16SD48 -OVAL TRAY STORAGE CABINET -SLIDING DOOR UTILITY STAND -REMOVABLE OVAL TRAY STORAGE -ELECTRIC CONDENSATE EVAPORATOR RACKS. -VERIFY TRAY SIZE (115V -1.74A) 30.9 MODEL NO,ISRR39R -REMOTE REF'G REDUCED RAIL WORK TABLE W -(1) SHELF PER DOOR SECTION 31.50 -(5) 1/6 SIZE PANS 6' DEEP BY OTHERS ® END -ADAPTER BARS BY OTHERS < .a o J o 0:) -HINGED REMOVABLE COVER E-' -1.50' DIA. HOLE FOR ACCESS TO I j y< POWER SWITCH IN PANEL FD -33F -41'F STORAGE IN TOP OPENING(S) y CID -36•F-40'F STORAGE IN BASE E --I -RAIL BTU'S = 180 Tri w n -BASE BTU'S= 343 DOOR R404A -115V-3OA c 0- c� -REF'G PACKAGE, R -404A I� -BASE PROVIDED WITH EXPANSION VALVE, ¢ x SOLENOID VALVE, AND THERMOSTATIC CONTROL -RAIL PROVIDED WITH EXPANSION VALVE, THERMOSTATIC CONTROL, AND SLILENDID VALVE WITH ON/OFF SWITCH -ELECTRIC CONDENSATE EVAPORATOR (115V -1.74A) PERMIT CENTER S/S I S7END END I I 36.00 I 40.00 -� L 7.62 6.12 LAMINATED EQUIPMENT FRONTS CDLDRI VERIFY LAMINATE GRAIN TO RUN VERTICAL D S/S�END S/S END 32.12 319 Compressor on left O O 27" REF'G 27" REF'G DOOR R404A DOOR R404A 319 36.25 AO Q D W A 27.13 9.13 MODEL TR -911 DETAIL 34.50 e -I S/S END 29.19 I } avo 30.9 411 MODEL ND, F2936C ITEM N0. 411 -SELF CONTAINED LOW -PROFILE REF'G BASE EQUIPMENT STAND -STANDARD W/CASTERS AND MARINE EDGE -TDP DRAWER SHALLOW DEPTH SIZED TO HOLD (1) FULL SIZE PAN -S15V-60C-1PH-3.841-1/5HP -REF'G PACKAGE, R -404A -BASE PROVIDED WITH EXPANSION VALVE AND THERMOSTATIC CONTROL -2.00 MINIMUM AIRSPACE AND HEAT BARRIER (SUCH AS BOTTOM OR DRIP PAN) REQUIRED BETWEEN COOKING EQUIPMENT AND EQUIPMENT STAND SIS 424 0 REFG R404A 0 REFG R404A 424 MODEL: D4432N-12M REM NO: 424 -SELF CONTAINED MECH. COOLED FRONT BREATHING MEGATOP REF'G -(12) 1/6 SIZE PANS a DEEP -PROVIDE WITH TELESCOPING COVER -ADAPTER BARS PROVIDED -TOP DRAWER ACCEPTS (2) 12 X 20 PANS 4-6' DEEP (BY OTHERS) -901TOM DRAWER ACCEPTS (2) 12 X 20 PANS e DEEP (BY OTHERS) -115V-60C-1PH-7.2A-1/5 HP (NEMA 5-15P) 8.50 S/S 7END END 44.50 36.00 r 2.50 610 610 J MODEL N0. 181 ITEM NO. 319 -SELF CONTAINED MECH. COOLED REFRIGERATED WORK TABLE -STANDARD WITH CASTERS -115V-60C-1PH-8.041-1/5 H.P. (NEMA #5-15P) -NOTE] CONVENTIONAL SPLINE TO OTHER EQUIPMENT NOT POSSIBLE WITH BST UNITS S/S END 3 7 you knead it. COMPONENT CRAFTED CUSTOM EQUIPMENT _ GENERAL NOTES: a}i -EXAMINE THIS DRAWING AND RESPOND TO NOTES IF APPLICABLE -ALL NOTES ARE STANDARD UNLESS OTHERWISE SPECIFIED FABBICATION: ALL LO -PRO TOPS TO BE 18 GAUGE SIS W ALL OTHER TOPS TO BE 16 GAUGE S/S WITH 14 GAUGE BRACING I... ALL EQUIPMENT FRONTS TO BE STAINLESS STEEL < ALL SHELVES TO BE STAINLESS STEEL WITH GALVANIZED G7 SUB -BRACING AND DOUBLE HEMMED NOSING FOR ADDED STRENGTH -CONSTRUCTION ADHESIVE IS USED ON ALL TOP AND SHELF SUCING FOR ADDED STRENGTH AND SOUND DEADENING -ALL LEGS ARE 6.00" ADJUSTABLE HEIGHT, S/S AND MOUNTED ON 1.50" LEG RAILS v1 VERIFICATION: O VERIFY SPACING OF SLIDES IN ALL RACK CABINETS C4 -VERIFY VOLTAGE & AMP RATINGS ON ALL ELECTRICAL OUTLETS '-' -VERIFY VOLTAGE REQUIRED ON HOT FOOD TABLES, LIGHTS, ETC 1 -VERIFY MA"00a. ELEL"TRtC:A1. AND INSTALLATION REQUIREMENTS TM OF ALL DISPENSERS DROP -INS, ROU. WARMERS, ETC -WHEN PLACING DISPENSERS IN TOP EXTENSIONS ONLY,ORDER Z . + cu M •t u7 DISPENSERS NO LONGER THAN 28.00' ELECTRICAL AI ALL FIELD WIRING JUNCTION BOXES ARE LOCATED SO THE BOXES CAN BE EXAMINED FROM THE FRONT SIDE OF THE COUNTER, AND THE CONNECTIONS CAN BE EXAMINED WITHOUT DISTURBING THE WIRING OR THE APPLIANCE -ALL 120 VOLT RECEPTACLES (15 AND 20 AMP) WILL BE GFCI PROTECTED DUPLEXES -ALL UNE -UPS WILL BE HARDWIRED 1N FIELD REMOTE REJ:RIGERATION• -REMOTE REFRIGERATORS ARE SUPPLIED WITH EXPANSION VALVE SOLENOID VALVE AND THERMOSTAT -REMOTE FREEZERS ARE SUPPLIED WITH EXPANSION VALVE; SOLENOID VALVE THERMOSTAT, AND DEFROST TIMER ALL OTHER CONTROLS ARE SUPPLIED BY OTHERS -DROP-IN COLD PANS ARE SUPPLIED WITH EXPANSION VALVE AND COURTESY PROBE TUBE OVERSTRUCTURE-HEATLAMP -SHELF HEIGHTS OF 19' RECOMMENDED TO ALLOW MINIMUM 14' CLEARANCE BETWEEN HEATIAMPS AND SHELF BELOW. -ALL HANGING HEATLAMPS MUST MEET MINIMUM 14" CLEARANCE BETWEEN HEATLAMP AND TOP SHELF ENVIRONMENTALLY FRIENDLY INSULATION -KYOTO PROTOCOL COMPLIA10 -NON O.D.P. (OZONE DEPLETION POTENTML -NON G.W.P. (GLOBAL WARMING POTENTIAL -POLYURETHANE INSULATION >i ® m 18.87 1 ,H17O6 2.03 AO Q D W A T19,50 3X SCALE TRAY RACK MODEL TR -911 DETAIL e -I Leave raised r. ai.l. on this f.;idea SE'° RATE PERNM V '�I i"Gt . L�GI'vIII' P`'(2UIRE: D FOF: 'achanic al c;CfilCe� R, Tubing Gas PIping i tyof Tukwila FR 1!LDI, I1 DIVISION 415 Compressor F refrigerated. Compressor on this side. AO Q D W A S/Sw�II e -I END } avo W z c)o CD 0) W o z OF-N�L7 W W 31.50 ® END d W < .a o J o 0:) W E-' Ca I j y< rp-,I QW Z 04 FD 3 y CID E --I W Tri w n z DOOR R404A W c 0- c� a ~ w aWi I� A 415 Compressor F refrigerated. Compressor on this side. AO Q D W A S/Sw�II e -I END } avo W c' c)o CD 0) W o z OF-N�L7 S/S S/S W 31.50 ® END d W < .a o J o 0:) W E-' Ca I j y< rp-,I QW Z 04 �� W J 3 415 Compressor F refrigerated. Compressor on this side. AO Q D W A e -I 0)Ir } avo W L4 A c)o CD 0) W o z OF-N�L7 S/S S/S w pj A P, ® END d W < .a o J o 0:) Wzg3_j _ - 40.00 Ca I j y< F'-00QA _ M o TR -9B 36.00 3 y CID 24" REF'G 24" REF END ODR R40 W Tri w n ,4z,Q W a z DOOR R404A W c 0- c� a ~ w aWi SKU ND. 000-201YDGX2 MODEL NO. 160539 I ITEM NO. 415 17PEN SHELF UTILITY STAND MODEL NO. ISVC62L -SELF CONTAINED REF'G REDUCED RAIL WORK TABLE -(1) SHELF PER DOOR SECTION -(4) 1/6 SIZE PANS 6' DEEP BY OTHERS -ADAPTER BARS BY OTHERS -HINGED REMOVABLE COVER -1.50' DIA. HOLE FOR ACCESS TO POWER SWITCH IN LOUVERED PANEL -33'F -41•F STORAGE IN TOP OPENINGS) -36•F -40'F STORAGE IN BASE -115V-60C-1PH-BIP -REF'G PACKAGE, R -404A -BASE PROVIDED WITH EXPANSION VALVE, SOLENOID VALVE, AND THERMOSTATIC CONTROL -RAIL PROVIDED WITH EXPANSION VALVE, PRESSURE CONTROL, AND SOLENOID VALVE WITH ON/OFF SWITCH -MODIFY RAIL TO BE LOCATED AT LEFT END -MODIFY TO HAVE FULL HEIGHT BASE -(1) MODEL TR -911 TRAY RACK WITH A CHROME FINISH Ido cerigas shalt ba made to the Se OM of work �^►btS�ourt pror approval o I: ui'di;ntg Division_ tJ 1Al rsL:ire a na•m plan sti offt an1.4 ad mal 1 r ►etly t 5 MODEL NO. 406 -CA ITEM NO. 610 -SELF CONTAINED COMPACT S/S UNDERC12UNTER REF'G END -PROVIDE WITH ALUMINUM SUBTOP -3.75 DIA CASTERS -115V-60C-1PH-5041-1/5HP (NEMA #5-15P) PJ "AWED FOR CC E CIOMPLIANCE APPROVED 7END PR 19 2016 33.25 ' l of Tu IS BUI DING DIVISION 3.75 702 TI R-40441 REF'G 702 S/S END Cco III, 4 ^ PW WZO 7.62 6.12 pq m (�glgF=-U w m 3 �+ MC3=) FXLE Copy open under shelves t A t(/ ` V D 7*- .: I Rtlb)I�yt tO y8ry0r_q BPIF y tr .:Yf')V. '..� t ivy Sl: 5[4'.x.+. ,.a `4�V Bnd i; rci tom Dy Date: `l� /�'f % Ci%► Of u"viia BUILDING DIVISION 0H 5 MODEL ND, 406 -CA -A33 ITEM NO, 702 -SELF CONTAINED COMPACT UNDERCOUNTER REF'G -PROVIDE WITH ALUMINUM SUBTOP -1,12' DIA CASTERS -115V-6OC-1PH-5.0A-1/5 H.P. (NEMA #5-15P) O -(1) PROVIDE ADDITIONAL SILVER FREEZE SHELF e -I W co II W°'CV � F+ -I zz IX x T-4 W RECEIVED IX CITY OF TUKWILA A ¢ x A APR 12 2016 O PERMIT CENTER z :3o �I W CD z IM X co zco w z a O WALK - IN SPECIFICATIONS ,l U OVERALL SIZE: 24'-011 X 8'-4" X 9'-6 1/4" _ Add floor w/ ramp in PANELS freezer section FOAMED IN PLACE URETHANE FOAM 4" EXTERIOR FINISH WALL: GALVALUME - EMBOSSED 26 GA TOP: GALVALUME - EMBOSSED 26 GA INTERIOR FINISH WALL: GALVALUME - EMBOSSED 26 GA TOP: GALVALUME - EMBOSSED 26 GA FLOOR TYPE F01 FREEZER: SCREED, METAL 4" HIGH C01 COOLER: SCREED, METAL 4" HIGH WALK-IN ACCESSORIES (4) TRIM ANGLED 3" X 3" X 8FT GALVALUME EMBOSSED 26 GA (83) LF, COVE BASE, GALVALUME EMBOSSED 26 GA 1.25 X 4.25 ON COMPLETE INTERIORS & EXPOSED EXTERIOR (1) LOT, TAPCON FASTENERS (1) LOT, RACKING CLIP (10) TIE DOWN ANGLE - 1-1/2" X 1-1/2" X 96" (INT WALL TO CL INCL PARTITIONS) (10) TIE DOWN ANGLE - 1-1/2" X 6" X 96" (W -IN FL TO FOUNDATION) REFRIGERATION PC249LOP-3 VOLTS: 208-230-60-3,BTU:8158 EL26-75-2EC-PR-4 VOLTS: 208-230-60-1,BTU:7500 TEMP: WALK-IN-10,AMBIENT TEMP: 100 (1) LAC -5-210-1/2 X 1/2 X 1/2 ODF HEADMASTER CTRL PC149MOP-3 VOLTS: 208-230-60-3,BTU:13142 AM28-122-IEC-PR-4 VOLTS: 115-60-1,BTU:12200 TEMP: WALK-IN 35,AMBIENT TEMP: 100 (1) LAC -4-210-3/8 X 3/8 X 3/8 ODF HEADMASTER CTRL BO 00 r\ 48X84 MIN MASONRY OPENING m OB 2143/" 731/" 1. DRAWING NOT INTENDED FOR INSTALLATION - DESIGN APPLICATION ONLY. 2. ALL WALK-INS ARE DESIGNED FOR INDOOR APPLICATION UNLESS NOTED OTHERWISE 3. PENETRATIONS AND SEALING OF ARE THE RESPONSIBILITY OF OTHERS 4. ALLOW 2" MINIMUM CLEARANCE WITH AIRFLOW OF 5 CFM PER 100 SQ FT AROUND ENTIRE PANEL SURFACES S. GENERAL CONTRACTOR TO REFER TO DESIGN AND SPECIFICATION MANUAL FOR FLOOR DETAIL INFORMATION 6. QUARRY TILE OR CONCRETE FLOOR APPLICATIONS: METAL PANEL FACING MAY BE SUSCEPTIBLE TO STAINING DUE TO EXCESSIVE MOISTURE CREATED BY THE HYDRATION OF CONCRETE TYPE MATERIALS. IT IS ABSOLUTELY NECESSARY THAT EACH ROOM BE PROPERLY VENTILATED. SPECIAL PRECAUTIONS MUST ALSO BE TAKEN WHEN USING MURIATIC ACID DUE TO EFFECTS HYDROCHLORIC FUMES HAVE ON METAL MATERIALS 7. PANEL LAYOUT MAY CHANGE BASED ON OPTIMAL MANUFACTURING STANDARDS 8. WALK-IN TOP IS NOT DESIGNED FOR FOOT TRAFFIC OR STORAGE UNLESS NOTED OTHERWISE 9. IF CONDENSING UNIT IS LOCATED IN THE INTERIOR OF BUILDING A MINIMUM OF 24" OF CLEARANCE IS REQUIRED AROUND TOP AND SIDES 10. FLOOR, CURB, AND PIT DETAILS ARE FOR GENERAL REFERENCE ONLY. THESE DRAWINGS SHOULD NOT BE USED OR INCORPORATED IN THE DESIGN OR PREPARATION OF THE INSULATED FLOOR, SUB -SLAB OR CURBS, WITHOUT HAVING THE DESIGN REVIEWED BY A QUALIFIED ENGINEER. ALL FOOTINGS, FOUNDATION WALLS AND CONCRETE WEAR SLABS ARE THE RESPONSIBILITY OF THE BUILDING ENGINEER OR ARCHITECT. 11. THE FOAM PLASTIC USED IN THIS PRODUCT COMPLIES TO THE IBC SECTION 2603 AS FOLLOWS: FLAME SPREAD RATING: 20; SMOKE DEVELOPED RATING: 450; FLASH IGNITION TEMPERATURE RATING: 9151f; SPONTANEOUS IGNITION TEMPERATURE RATING: 9500f. Saved on 016 10:08:29 AM by KYPSAUU. 16'-2" R, 16'- " -0h LAYOUT ColCOOLER: NO FLOOR 9'- 6 1/4" O.A. HEIGHT 5/8" I.D. Re ocate UUUi to this location and make same size as Freezer door FOR APPROVAL YOU MUST REVIEW ALL NOTES, DETAILS, DIMENSIONS, FINISHES, DOORS SIZES, LOCATIONS AND SWINGS r loor w/ ramp 1n freezer section ul W U V .00'£Z .00'£Z .04'L£ .0091` = _ = Ilk 'LS I I �N� m Z � CV c4 ( ( 0 1055/x" 36%" t~ 51%" of C� 8 # iM 1 8 8 N o Mirror Door •$ 8 S g 89 Ln Hindging X g S c� 34.25" II 8 XX g F M g F M li 8 F 15" M M g F 1 M � 1 r-', ,g S s4 1 N 3ifM3 00'6£ L 4 i' 1 28-7/8" $ 1 oI V ao �i U U $ (=p RI N � ca N 8 Ln kA 42.50" 23.00' 37.50' 46.00' 46.00" 46.00" I N 1. DRAWING NOT INTENDED FOR INSTALLATION - DESIGN APPLICATION ONLY. 2. ALL WALK-INS ARE DESIGNED FOR INDOOR APPLICATION UNLESS NOTED OTHERWISE 3. PENETRATIONS AND SEALING OF ARE THE RESPONSIBILITY OF OTHERS 4. ALLOW 2" MINIMUM CLEARANCE WITH AIRFLOW OF 5 CFM PER 100 SQ FT AROUND ENTIRE PANEL SURFACES S. GENERAL CONTRACTOR TO REFER TO DESIGN AND SPECIFICATION MANUAL FOR FLOOR DETAIL INFORMATION 6. QUARRY TILE OR CONCRETE FLOOR APPLICATIONS: METAL PANEL FACING MAY BE SUSCEPTIBLE TO STAINING DUE TO EXCESSIVE MOISTURE CREATED BY THE HYDRATION OF CONCRETE TYPE MATERIALS. IT IS ABSOLUTELY NECESSARY THAT EACH ROOM BE PROPERLY VENTILATED. SPECIAL PRECAUTIONS MUST ALSO BE TAKEN WHEN USING MURIATIC ACID DUE TO EFFECTS HYDROCHLORIC FUMES HAVE ON METAL MATERIALS 7. PANEL LAYOUT MAY CHANGE BASED ON OPTIMAL MANUFACTURING STANDARDS 8. WALK-IN TOP IS NOT DESIGNED FOR FOOT TRAFFIC OR STORAGE UNLESS NOTED OTHERWISE 9. IF CONDENSING UNIT IS LOCATED IN THE INTERIOR OF BUILDING A MINIMUM OF 24" OF CLEARANCE IS REQUIRED AROUND TOP AND SIDES 10. FLOOR, CURB, AND PIT DETAILS ARE FOR GENERAL REFERENCE ONLY. THESE DRAWINGS SHOULD NOT BE USED OR INCORPORATED IN THE DESIGN OR PREPARATION OF THE INSULATED FLOOR, SUB -SLAB OR CURBS, WITHOUT HAVING THE DESIGN REVIEWED BY A QUALIFIED ENGINEER. ALL FOOTINGS, FOUNDATION WALLS AND CONCRETE WEAR SLABS ARE THE RESPONSIBILITY OF THE BUILDING ENGINEER OR ARCHITECT. 11. THE FOAM PLASTIC USED IN THIS PRODUCT COMPLIES TO THE IBC SECTION 2603 AS FOLLOWS: FLAME SPREAD RATING: 20; SMOKE DEVELOPED RATING: 450; FLASH IGNITION TEMPERATURE RATING: 9151f; SPONTANEOUS IGNITION TEMPERATURE RATING: 9500f. Saved on 016 10:08:29 AM by KYPSAUU. 16'-2" R, 16'- " -0h LAYOUT ColCOOLER: NO FLOOR 9'- 6 1/4" O.A. HEIGHT 5/8" I.D. Re ocate UUUi to this location and make same size as Freezer door FOR APPROVAL YOU MUST REVIEW ALL NOTES, DETAILS, DIMENSIONS, FINISHES, DOORS SIZES, LOCATIONS AND SWINGS r loor w/ ramp 1n freezer section 00 00 LU I z w U I I 151-411- C? 5'-4"- 0 TOPS LAYOUT 4'-9%" 31-10%11 'NOTE: DOOR JAMB EXTENDS DOWN PAST INOTE:DOOR JAMB I =1 11 SCREEDS TO FLOOR. N EXTENDS DOWN PAST LnT SCREEDS TO FLOOR. 4 I ' \ I i—if � ! T-3" CENTER TO CENTER ❑ APPROVAL- NO CHANGE REQUIRED, MANUFACTURE AS DRAWN. Panels with non -textured and/or no -profile panel finishes (smooth finishes) on the ❑ APPROVED AS NOTED- MAKE REQUIRED CHANGES AND exterior and interior faces may exhibit ""oil canning" and flatness imperfections on the MANUFACTURE AS DRAWN. surface. Our standard panels have a stucco embossed texture on both faces that helps to Dfl NOT APPROVED- DESIGN CHANGES REQUIRE DRAWING reduce oil canning and any other irregularities in the exposed surface. Please be aware REVISION AND RESUBMISSION. of this potential situation in your specification process. Such "oil canning" and flatness DATE: BY: issues are typical and are not covered under standard warranties. FLOORS LAYOUT 16'-5" CENTER TO CENTER RECEIVED CITY OF TUKWILA APR 12 2016 PERMIT CENTER CNI c M f�! Ot rq 0 0 Ce Z W �=o°c O D W 0 Z 2 V) W O 'a m ul W U V = o I �N� m Z � CV C.1 of a ( ( 0 1= 1g of C� 8 # iM 1 8 8 8 S 8 S 8 89 X g S g 8 XX g F M g F M li 8 F X M F M S F M g F 1 M � 1 1 N i i' 1 4 $ 1 oI V U U $ (=p RI 11 ca I kA 1� 1 I N 8 —46.00"---�— � —46.00"-- '- 200 42.50" — T 231V— T 3.00" T 3:.50"--�— —46.00"---�— T-11 00 00 LU I z w U I I 151-411- C? 5'-4"- 0 TOPS LAYOUT 4'-9%" 31-10%11 'NOTE: DOOR JAMB EXTENDS DOWN PAST INOTE:DOOR JAMB I =1 11 SCREEDS TO FLOOR. N EXTENDS DOWN PAST LnT SCREEDS TO FLOOR. 4 I ' \ I i—if � ! T-3" CENTER TO CENTER ❑ APPROVAL- NO CHANGE REQUIRED, MANUFACTURE AS DRAWN. Panels with non -textured and/or no -profile panel finishes (smooth finishes) on the ❑ APPROVED AS NOTED- MAKE REQUIRED CHANGES AND exterior and interior faces may exhibit ""oil canning" and flatness imperfections on the MANUFACTURE AS DRAWN. surface. Our standard panels have a stucco embossed texture on both faces that helps to Dfl NOT APPROVED- DESIGN CHANGES REQUIRE DRAWING reduce oil canning and any other irregularities in the exposed surface. Please be aware REVISION AND RESUBMISSION. of this potential situation in your specification process. Such "oil canning" and flatness DATE: BY: issues are typical and are not covered under standard warranties. FLOORS LAYOUT 16'-5" CENTER TO CENTER RECEIVED CITY OF TUKWILA APR 12 2016 PERMIT CENTER CNI c M f�! Ot rq 0 0 Ce Z W �=o°c O D W 0 Z 2 V) W O 'a m ul W U V = o m Z � 0 ILAF SHEET # i OFFSET DR 36.00" x 78.00" FR 64.50" x 110.25" DW -1 FRAME: RECESSED 0" WITH 0" LEVELING SAND AND 0.625" TILE AND GROUT EXT: GALVALUME - EMBOSSED 26 GA INT: GALVALUME - EMBOSSED 26 GA PLUG: EXT: GALVALUME - EMBOSSED 26 GA EXT: KICKPLATE, ALUM .063 DIAMOND TREAD 36" HIGH INT: GALVALUME - EMBOSSED 26 GA INT: KICKPLATE, ALUM .063 DIAMOND TREAD 36" HIGH HARDWARE AND ACCESSORIES: (1) TILE AND GROUT ADDER (1) VENT - PRESSURE RELIEF, HEATED KASON 1825 (1) SWITCH - PILOT LIGHT INCLUDED UL (1) EVAPORATOR FAN CUTOFF (EXT. MOUNTED) (1) THERMOMETER - DIGITAL (1) LIGHT VAPOR PROOF ASY (1) DOOR CLOSER - KASON 1098 (W/COVER AND HOOK) (1) VIEWPORT - 14X14 FREEZER, HEATED FRAME AND GLASS (4" DOOR) (1) HANDLE - KASON 28 (WITH LOCKING ASSEMBLY) (1) THRESHOLD, STAINLESS STEEL 14 GA (1) HEATER WIRE, 2.5 WATT / FT (2) HINGE - KASON 1345 ADJUSTABLE (SPRING ASSISTED) u DOOR /,SWEEP GASKET FLAT BOTTOM WALL ' HEATER WIRE TILE AND GROUT / BOTTOM PLATE THICKNESS � //THRESHOLD / FINISHED FLOOR 2" MIN. ER URETHANE TILE AND GROUT REQUIRED FOR FRZ THICKNESS OPTIONAL FOR CLR / - (BY OTHERS) REDWOOD MEMBER SPACERS ' VAPOR BARRIER REQUIRED FOR FRZ (AS REQUIRED) REQUIRED FOR FRZ ' OPTIONAL FOR CLR OPTIONAL FOR CLR (BY OTHERS) (BY OTHERS) DETAIL -FLAT 130TTOM-TSG DETAIL=FI.�tT Scale. NTS Scale: NTS COMPARTMENT TEMP F COMPRESSOR DESCRIPTION WI QTY MODEL# TYPE Freezer -10 1 PC249LOP-3 Hermetic Cooler 35 1 PC149MOP-3 Hermetic COMPARTMENT TEMP F MODEL # DESCRIPTION WI QTY (DEFROST: A -AIR &ELECTRIC) Freezer -10 1 EL26-75-2EC-PR-4 Cooler 35 1 AM28-122-1EC-PR-4 Saved on 1/19/2016 10:08-:29 ArTH3y4 60 • M - d- 00 M OFFSET 2.00 DR 36.00" x 78.00" FR 57.50" x 110.25" DW -2 FRAME: RECESSED 0" WITH 0" LEVELING SAND AND 0.625" TILE AND GROUT EXT: GALVALUME - EMBOSSED 26 GA INT: GALVALUME - EMBOSSED 26 GA PLUG: EXT: GALVALUME - EMBOSSED 26 GA EXT: KICKPLATE, ALUM .063 DIAMOND TREAD 36" HIGH INT: GALVALUME - EMBOSSED 26 GA INT: KICKPLATE, ALUM .063 DIAMOND TREAD 36" HIGH HARDWARE AND ACCESSORIES: (1) SWITCH - PILOT LIGHT INCLUDED UL (1) LIGHT VAPOR PROOF ASY (1) THERMOMETER - DIGITAL (1) EVAPORATOR FAN CUTOFF (EXT. MOUNTED) (1) TILE AND GROUT ADDER (2) HINGE - KASON 1345 ADJUSTABLE (SPRING ASSISTED) (1) HANDLE - KASON 28 (WITH LOCKING ASSEMBLY) (1) DOOR CLOSER - KASON 1098 (W/COVER AND HOOK) (1) VIEWPORT - 14X14 COOLER, HEATED FRAME (4" DOOR) 100 DOOR ELECTRICAL INFORMATION 1-1/2 DESCRIPTION QTY VOLT AMP AMP LOAD VAPOR PROOF LIGHT 1 1.0 1.7 0.4 0.9 0.1 115 0.1 0.9 1.4 0.1 6.0 1 1.0 1 1.0 0.0 0.0 0.9 0.1 0.1 0.9 0.0 0.0 0.0 0.0 FLUORESCENT LIGHT 0 LED LIGHT 0 HEATER WIRE 1 DIGITAL THERMOMETER 1 HEATED AIR VENT 1 HEATED VIEWPORT 1 AIR SHIELD 0 IN/OUT BUZZER 0 MODULARM 75175B OR DATALARM 0 OTHER ALARMS 0 (A) 115 VOLT, SINGLE PHASE, 60 Hz, TOTAL DOOR AMPS:1 3.0 DOOR /,SWEEP GASKET FLAT BOTTOM WALL ' HEATER WIRE TILE AND GROUT / BOTTOM PLATE THICKNESS � //THRESHOLD / FINISHED FLOOR 2" MIN. ER URETHANE TILE AND GROUT REQUIRED FOR FRZ THICKNESS OPTIONAL FOR CLR / - (BY OTHERS) REDWOOD MEMBER SPACERS ' VAPOR BARRIER REQUIRED FOR FRZ (AS REQUIRED) REQUIRED FOR FRZ ' OPTIONAL FOR CLR OPTIONAL FOR CLR (BY OTHERS) (BY OTHERS) DETAIL -FLAT 130TTOM-TSG DETAIL=FI.�tT Scale. NTS Scale: NTS COMPARTMENT TEMP F COMPRESSOR DESCRIPTION WI QTY MODEL# TYPE Freezer -10 1 PC249LOP-3 Hermetic Cooler 35 1 PC149MOP-3 Hermetic COMPARTMENT TEMP F MODEL # DESCRIPTION WI QTY (DEFROST: A -AIR &ELECTRIC) Freezer -10 1 EL26-75-2EC-PR-4 Cooler 35 1 AM28-122-1EC-PR-4 Saved on 1/19/2016 10:08-:29 ArTH3y4 60 • M - d- 00 M OFFSET 2.00 DR 36.00" x 78.00" FR 57.50" x 110.25" DW -2 FRAME: RECESSED 0" WITH 0" LEVELING SAND AND 0.625" TILE AND GROUT EXT: GALVALUME - EMBOSSED 26 GA INT: GALVALUME - EMBOSSED 26 GA PLUG: EXT: GALVALUME - EMBOSSED 26 GA EXT: KICKPLATE, ALUM .063 DIAMOND TREAD 36" HIGH INT: GALVALUME - EMBOSSED 26 GA INT: KICKPLATE, ALUM .063 DIAMOND TREAD 36" HIGH HARDWARE AND ACCESSORIES: (1) SWITCH - PILOT LIGHT INCLUDED UL (1) LIGHT VAPOR PROOF ASY (1) THERMOMETER - DIGITAL (1) EVAPORATOR FAN CUTOFF (EXT. MOUNTED) (1) TILE AND GROUT ADDER (2) HINGE - KASON 1345 ADJUSTABLE (SPRING ASSISTED) (1) HANDLE - KASON 28 (WITH LOCKING ASSEMBLY) (1) DOOR CLOSER - KASON 1098 (W/COVER AND HOOK) (1) VIEWPORT - 14X14 COOLER, HEATED FRAME (4" DOOR) 100 SWEEP GASKET FLAT BOTTOM WALL /FINISHED FLOOR IF REQUIRED, PLACE LEVELING 1/4" x 4" TAPCON ANCHOR, PHILLIPS SHIMS AT EACH SCREW FLAT HEAD. USE 3/16" x 6-1/2" LOCATION TO MAINTAIN A` JCONCRETE DRILL BIT #790-1026 LEVEL FLOOR. % OR EQUAL (28930-1075); DRILL THRU HOLE. FINISH FLOOR, 1 METAL SCREED �1-1/4" MIN FASTENER AT 11.5" ON CENTER DETAIL - TAPCON ANCHOR F t-riuimu rmmr- M WALL PANEL LOCKS STRIKES L� RACKING CLIPS r EL M F FLOOR PANEL OR SCREED DETAIL - RACKING CLIP Scale: NTS Scale: NTS DOOR ELECTRICAL INFORMATION 1-1/2 DESCRIPTION QTY VOLT AMP AMP LOAD VAPOR PROOF LIGHT 1 1.0 1.7 0.4 0.9 0.1 115 0.1 0.9 1.4 0.1 6.0 1 1.00.0 1.0 0.0 0.0 0.0 0.1 0.0 0.9 0.0 0.0 0.0 FLUORESCENT LIGHT 0 LED LIGHT 0 HEATER WIRE 0 DIGITAL THERMOMETER 1 HEATED AIR VENT 0 HEATED VIEWPORT 1 AIR SHIELD 0 IN/OUT BUZZER 0 MODULARM 75/756 OR DATALARM 0 OTHER ALARMS 1 0 (A) 115 VOLT, SINGLE PRASE, 60 Hz, TOTAL DOOR AMPS: 2.0 SWEEP GASKET FLAT BOTTOM WALL /FINISHED FLOOR IF REQUIRED, PLACE LEVELING 1/4" x 4" TAPCON ANCHOR, PHILLIPS SHIMS AT EACH SCREW FLAT HEAD. USE 3/16" x 6-1/2" LOCATION TO MAINTAIN A` JCONCRETE DRILL BIT #790-1026 LEVEL FLOOR. % OR EQUAL (28930-1075); DRILL THRU HOLE. FINISH FLOOR, 1 METAL SCREED �1-1/4" MIN FASTENER AT 11.5" ON CENTER DETAIL - TAPCON ANCHOR F t-riuimu rmmr- M WALL PANEL LOCKS STRIKES L� RACKING CLIPS r EL M F FLOOR PANEL OR SCREED DETAIL - RACKING CLIP Scale: NTS Scale: NTS [R 'WED FOR CODE CQMPLIANCE APPROV15D APR 19 2016 i J City of Tukv Ila BUILDING DIVISION FLOOR OR METAL SCREED DETAIL - PANEL CONNECTION AT FLOORS OR METAL SCREEDS ,Scale: NTS CONNECTIONS O.D. SUCT LIQ 7/8 3/8 7/8T7 3/8 CONNECTIONS O.D. SUCT LIQ 7/8 3/8 7/8 3/8 RCV CAP @ 90% FULL (lbs) 13.6 10.4 DRAIN 3/4 3/4 4 x 1" HEX HEAD TEK VS (12" ON CENTER?) L.5" TIE DOWN ANGLE rCH CEILING FINISH DETAIL - TIE DOWN ANGLE -INT WALL TO CL INCLUDING 1-1/2 ANCHOR HEX WASHER 1/4" x #14 x 1" HEX HEAD; USE 3/16" x 4-1/2" CONDENSING UNIT CONCRETE DRILL, TAPCON 3 ON CENTER (500000038)'\,, BIT #790-1018 OR DIMENSIONS Z O COMPRESSOR 14 GA. PAINTED CONDENSER FAN MTR TOTAL AMPS MX AMP DISC (A) W (B) H (C) LBS HP RLA LRA V HZ 0 FLA V 0 EL 33 40.125 22.25 213 212 10.2 72.2 208-230 60 3 2.2 208-230 1 12.6 25 33 25.5 19.25 163 11/2 6.4 52 208-230 60 3 1.1 208-230 1 7.7 15 APR 12 2016 m 3 UNIT COOLER 0 DIMENSIONS PERMIT CENTER FAN HEATER ACD L (D) W (E) H (F) LBS AMP V AMP V 0 41.5 15 15.25 67 0.9 208-230 17 208-230 1 41.5 15 15.25 74 1.8 115 0 N/A 0 [R 'WED FOR CODE CQMPLIANCE APPROV15D APR 19 2016 i J City of Tukv Ila BUILDING DIVISION FLOOR OR METAL SCREED DETAIL - PANEL CONNECTION AT FLOORS OR METAL SCREEDS ,Scale: NTS CONNECTIONS O.D. SUCT LIQ 7/8 3/8 7/8T7 3/8 CONNECTIONS O.D. SUCT LIQ 7/8 3/8 7/8 3/8 RCV CAP @ 90% FULL (lbs) 13.6 10.4 DRAIN 3/4 3/4 4 x 1" HEX HEAD TEK VS (12" ON CENTER?) L.5" TIE DOWN ANGLE rCH CEILING FINISH DETAIL - TIE DOWN ANGLE -INT WALL TO CL INCLUDING DETAIL - TIE DOWN ANGLE -WALK IN TO FOUNDATION-TAPCON CONDENSING UNIT ASSEMBLY AIR INLETB EVAPORATOR - MODEL AM, EM, EL, AMB, ELB F D � E� o 0 0 0 0eso F LIQUID E1.EC'Rt:AL NNETON hif'T DRk,I:"i CDNNECiIONS SU0,10N iI^: EE 4R (IN REAP) CO INECT1ON (IN FEAR) CLEARANCE REQUIREMENT 1/4" x 1-3/4" TAPCON ANCHOR HEX WASHER 1/4" x #14 x 1" HEX HEAD; USE 3/16" x 4-1/2" WASHER HEAD TEK SCREWS, CONCRETE DRILL, TAPCON 3 ON CENTER (500000038)'\,, BIT #790-1018 OR MINIMUM CLEARANCE 36^ REQUIRED Ig^ REQUIRED FOR FOR PP.OPPER OPERATION SERVICING Z O EQUAL (28931-1075); 14 GA. PAINTED TAPCONS ARE 6" ON SHEET METAL ANGLE . p CENTER WITH MINIMUM 1-1/2" x 6" (28911-1090) i,l1-1/4" EMBEDMENT. FOUNDATION FASTENER AT 11.5" ON CENTER DETAIL - TIE DOWN ANGLE -WALK IN TO FOUNDATION-TAPCON CONDENSING UNIT ASSEMBLY AIR INLETB EVAPORATOR - MODEL AM, EM, EL, AMB, ELB F D � E� o 0 0 0 0eso F LIQUID E1.EC'Rt:AL NNETON hif'T DRk,I:"i CDNNECiIONS SU0,10N iI^: EE 4R (IN REAP) CO INECT1ON (IN FEAR) CLEARANCE REQUIREMENT a 0 MINIMUM CLEARANCE 36^ REQUIRED Ig^ REQUIRED FOR FOR PP.OPPER OPERATION SERVICING Z O N s 0 a AIR FLOW SIDE VIEW o m sn x V RECEIVED • N CITY OF TUKWILA APR 12 2016 m 3 " 0 PERMIT CENTER SHEET # ACD -2 Of 2 GENERAL NOTES 1. SINGLE -PLY ROOFING SYSTEM WITH BASE FLASHING SHEET EXTENDING UP PARAPET AND TERMINATED UNDER COPING HOT WELDED TO SEALING STRIP SECURED TO WOOD BLOCKING 2. INSTALLATION OF ROOFING SHALL BE IN ACCORDANCE WITH MANUFACTURER'S SPECIFICATIONS U �, 0 0 AND PER DETAIL 2 OF THIS SHEET. ° -0 a 3. PROVIDE PREFABRICATED METAL CURBS. COORDINATE SIZE, LOCATION AND INSTALLATION b-� s o= ° o = 2 REQUIREMENTS W/ M, E, P & S SHEETS. PROVIDE SHIMS TO LEVEL CURB AREAS WHERE =o 0 ROOF DECK IS PITCHED. ° ` ° °to4. FOR EXACT LOCATION OF EXHAUST FANS, HVAC UNITS, AND ROOF HATCH. REFER TO � o o = a � j STRUCTURAL DRAWINGS. LO 4JC)o N L -O o Q 2 2 c 5. CRICKETS MUST BE INSTALLED AT ALL ROOF CURBS & EQUIPMENT PLATFORMS BY GENERAL c "' o a m o CONTRACTOR. N D� a o o • m i O a E -0 6 moms I m o ' KEY NOTES (NOT ALL KEY NOTES ARE USED) v Q U U _c U ' o�Q) t� a E o a ---- - I SLOPE DN SLOPE DN E W G L A I I O (E) PARAPET TO REMAIN. O (E) ROOF DRAIN. Z a � y � M2 N �- cn o 0 C ° u N t L c A F --------------- i — O (E) BRACING/CRICKETING TO REMAIN. G •� i II p (N) MECHANICAL HVAC UNIT, SEE STRUCTURAL AND MECHANICAL/ELECTRICAL DRAWINGS. O - ..................................................................- � i EF -2 FREEZER-CONDENSN` � I E E O PLUMBING VENT. :.. 1 � I I .... ................ .. .. .. ..... . A ll� ...I-- --- - --- i I COOLER -CONDENSER F (N) EXHAUST FAN, SEE MECHANICAL/ELECTRICAL DRAWINGS. i i O (N) CONDENSER UNITS, SEE MECHANICAL, ELECTRICAL AND KITCHEN DRAWINGS. .. ... ' I � -- ----------------------------------'--�� -------------------- _� - t-- � i � O (N) MAKE UP AIR UNIT, SEE STRUCTURAL AND MECHANICAL/ELECTRICAL DRAWINGS. ...: .................:.:...:.:....... I j I H MAU-1 Y O (N) AWNING STRUCTURE AND FABRIC BELOW. COORDINATE W/ AWNING SUPPLIER. Q ::.:.:.:.:.:.:: :::.:.:.:::.:.::.:.:::.:.:::." I RTU -4 ( EF -1 F I I O OUTLINE OF CORNER BAKERY CAFE'S DEMISING WALL BELOW. CO J00 > ..................... .......I............ I p M -� �� T I I OUTLINE OF FREEZER/COOLER BELOW OUTLINE _ 0— LL m � rn N I, :::.::::.:.:.:.:.:.:.:::.:::::.:::' . I N I X II O COORDINATE EXACT LOCATION OF (N) HVAC AND DUCT DROPS IN FIELD. -ijj 0 Q �� W a_ :":".:" I I i I I N (E) STANDING SEAM ROOF ASSEMBLY O Z CCS w Co W LL. :...::::::...::::'::::• I I ;, G �� G �. <t>E ROOF HATCH AND LADDER FOR ROOF ACCESS. U (D cy �— O U 0O ::'...:.'_..:....:..: I I E I ,- .,��'� I I O INSTALL 2'-6° WALKWAY PADS FROM ROOF ACCESS TO (N) RTUS. O ::: ::::::::..... I -2 E RTU -1 E I( I O NOT USED F4w :::..... I p M I I D M I SALAD-CONEDNSER EXPO-CONEDENSER I( O OUTLINE OF HOODS BELOW .:::. B J I N I I I N T (E) ROOF TO REMAIN; EXISTING EQUIPMENT ON CORNER BAKERY SPACE TO BE BE REMOVED O BY GC. REMOVE ABANDONED ROOF VENTS AND CAP, PATCH AND REAPIR TO MATCH EXISTING ROOF CONSTRUCTION FOR WEATHER-11GHT SEAL, TYP. GC TO VERIFY CONDITION OF ROOF AND REPORT ANY EXISTING DAMAGES PRIOR TO COMMENCING WORK. GC TO PATCH AND F \r — — — REPAIR EXISTING ROOF DUE TO DEMO OR NEW WORK. II O (E) SKYLIGHT TO REMAIN I OGAS PENETRATION THROUGH ROOF REF. DETAIL 07/A131 AND PLUMBING SHEETS FOR MORE INFORMATION. I I W CONCENTRIC GAS FLU AND AIR INTAKE; REF. DETAIL 07/A131 AND PLUMBING SHEETS FOR > Z G a I I I MORE INFORMATION. O REFRIGERANT PIPE CURB AND COVER; REF. PM SHEETS FOR MORE INFORMATION. NO REVISION ISSUED FOR PERMIT 10/08/2015 N I K II Y (N) SANITARY VENT, SEE MECHANICAL/PLUMBING DRAWINGS. & BID REV PER CITY COMMENTS 11/20/2015 ISSUED FOR 12/18/2015 B B B 0 CONSTRUCTION LEGEND I EXISTING TO REMAIN. J — — — — — — LINE OF WALL, BELOW. I W I II EXISTING CRICKETING I I I I II I j PIPE OR CONDUIT THRU ROOF I B I I DRAW BAND ""-""•" ! I i FLEXIBLE BOOT • RTU -3 E l l N .................... ............. ; I •: •• .• I I METAL FLASHING SLEEVE O .. . I I ROOFING ' ......:::::..... I I o v J :•:•:•:•:•:....:..:...:..:...:• • . . ....:.....:.....:...:...:.:.............:...:... j L_ 1 W ........................ :•:•:•:•:....:•:•:•:•:.:•:•:•:•:•:•:•:•:::•:... O :::": : :: : :::: : : : :: : :"::..:.;..:.:.:.:.:. ......._ ! T I I I I STRUCTURE (OR STRUCTURAL SUB -MEMBER AS NECESSARY) I I O .".."...."...":"....•....."."..•"."..............."."... ::-::::::::::::::-::=:":::. ....................................... - - - -r - - - PIPE FLASHING *SCALE: L.�._ 0 3" = 1'-0" SEE DETAIL 06/A131 D FOR FLASHING AT PIPE THROUGH ROOF U� ^^ J I PARAPET WALL �v! v ) E a ' A MECHANICAL L0 N D PCXR EQUIPMENT CURB, SEE r N � - f PLIANT DETAIL 05/A131 N o A - - - - - - - - - Ii3� y PCE00 APR 1 2016 e Q BUILDING DIVISION DRAWN BY: EW,CA CHECKED BY' AH,SM PROJECT NUMBER C 0 ® 12" MINIMUM CLEAR BETWEENPENETRA11ON SLEEVE BOTTOM OF CANT AT AND 2007855013 w 1 2 3) 5 5.500 PARAPET WALL 12" MINIMUM CLEAR BETWEEN w - PENETRATION SLEEVES SHEET N U M B E F� 0 Z ^ I 2 12" MINIMUM CLEAR BETWEEN REC VE� PENETRATION SLEEVE AND CITY O 'i'tJKWILA NOTE BOTTOM OF CANT AT MECHANICAL CURB APR 12 2016 Ala V)w m Lu 01 ROOF PLAN N ROOF EQUIPMENT LAYOUT REVISED TO INCORPORATE USE OF EXISTING UNITS. REFER TO ENGINEERING SHEETS FOR ADDITIONAL INFORMATION. 07 ROOF PENETRATIONS PERMIT CENTER )SCALE: Roof Plan SCALE: 1 /4" = 1'-0" 1/2" = V -0 - DATE OF THIS PRINTING -Jan 09, 2016