HomeMy WebLinkAboutPermit M16-0058 - 4501 BUILDING - DUCTWORK AND GRILLES/DIFFUSERS4501 BUILDING 450IS134 TH PL M16-0058 City of Tukwila • Department of Community Development • 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-438-9350 Web site: http://www.TukwilaWA.gov MECHANICAL PERMIT Parcel No: 2613200045 Address: 4501 S 134TH PL Project Name: 4501 BUILDING Owner: Name: SMITH COURT LLC Address: PO BOX 146, RENTON, WA, 98057 Contact Person: 2014 Name: ALEX BURKHART Address: 727 S KENYON ST, SEATTLE, WA, International Mechanical Code Edition: 98108 Contractor: 2014 Name: EVERGREEN REFRIGERATION LLC Address: 727 S KENYON ST, SEATTLE, WA, International Fuel Gas Code: 98108 License No: EVERGRL954R2 Lender: Name: Address: Permit Number: M16-0058 Issue Date: 5/13/2016 Permit Expires On: 11/9/2016 Phone: (206) 763-1744 Phone: (206) 763-1744 Expiration Date: 1/6/2018 DESCRIPTION OF WORK: INSTALLATION OF DUCTWORK AND GRILLES/DIFFUSERS Valuation of Work: $1,805.00 Fees Collected: $221.32 Type of Work: NEW Electrical Service Provided by: SEATTLE CITY LIGHT Fuel type: Water District: 125 Sewer District: TUKWILA SEWER SERVICE,VALLEY VIEW SEWER SERVICE Current Codes adopted by the City of Tukwila: International Building Code Edition: 2012 National Electrical Code: 2014 International Residential Code Edition: 2012 WA Cities Electrical Code: 2014 International Mechanical Code Edition: 2012 WAC 296-4613: 2014 Uniform Plumbing Code Edition: 2012 WA State Energy Code: 2012 International Fuel Gas Code: 2012 Permit Center Authorized Signatu Date: �;– — I IN I hearby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this development permit and agree to the conditions attached to this permit. Signature: 4— Date: Print Name: 0"t— This `t This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: Work shall be installed in accordance with the approved construction documents, and any changes made during construction that are not in accordance with the approved construction documents shall be resubmitted for approval. 2: All permits, inspection record card and approved construction documents shall be kept at the site of work and shall be open to inspection by the Building Inspector until final inspection approval is granted. 3: All construction shall be done in conformance with the Washington State Building Code and the Washington State Energy Code. 4: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 5: ***MECHANICAL PERMIT CONDITIONS*** 6: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431-3670). 7: Manufacturers installation instructions shall be available on the job site at the time of inspection. PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 1800 MECHANICAL FINAL 0701 ROUGH -IN MECHANICAL CITY OF TUKW' Community Developmen. Department Permit Center • 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.TukwilaWA.gov Mechanical Per>L.i-dt No. Project No. Date Application Accepted: I Date Application Expires: (For office use on MECHANICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. "please print" SITE LOCATION ��°Q ����, King Co Assessor's Tax No.: 2b � 3 G-(, Lf -5 `� Site Address: - l S 0 ( S I - Suite Number: Floor: Tenant Name: New Tenant: ❑ .....Yes ❑ ..No PROPERTY OWNER Name: C,_ i44, 6a,,+ Address: i70 , X I c . f City: �L�h ` State: Lv/k Zip:�gV CONTACT PERSON - person receiving all project communication Name: - Address: 2 A J City: 5 1 �, t�'�56.4, VState: 1en Zip: 41g f Phone: ?p6 -63 _ (-ILH Fax: U6 --K312,3 g`1 Email: Q,Le�k LeG VIQ4+kvK, &l`-,. Valuation of project (contractor's bid price): $ I OU UP MECHANICAL CONTRACTOR INFORMATION Company Name: Address: IV -7 City: < % State: V4A- Zip: q 9 A Phone: ��- � j - (-Ic44 Fax: 1,0 6 Z30 Contr Reg No.: pVD pp&ViA s lZ xp Date: [Tukwila Business License No.: F?"", Describe the gscoppe,,of works in detail: L �/j�� Id Use: Residential: New .......... ❑ Replacement ........ ❑ Commercial: New .......... F?"", Replacement ........ ❑ Fuel Type: Electric..... ❑ Gas ....... ❑ Other:_ H:Wppliwtions\Forms-Applications On Line\2016 ApplicationsWechanical Permit Application Revised 1-4-16.docx Revised: January 2016 Pagel of 2 bh Indicate type of mechanical work being installed and the quantity below: Unit Type Qty Furnace <I OOk btu Residential, Nighttime Furnace >I OOk btu Industrial Floor furnace 55 dB(A) Suspended/wall/floor mounted heater 57 dB(A) Appliance vent Commercial Repair or addition to heat/refrig/cooling system 47 dB(A) Air handling unit <10.000 cfm 65 dB(A) Unit Type Qty Air handling unit >I0,000 cfm Residential, Nighttime Evaporator cooler Industrial Ventilation fan connected to single duct 55 dB(A) Ventilation system 57 dB(A) Hood and duct Commercial Incinerator — domestic 47 dB(A) Incinerator — comm/industrial 65 dB(A) Unit Type Qty Fire damper Residential, Nighttime Diffuser Industrial Thermostat 55 dB(A) Wood/gas stove 57 dB(A) Emergency enerator Commercial Other mechanical equipment 47 dB(A) 60 dB(A) 65 dB(A) Boiler/Compressor Qty 0-3 hp/100,000 btu 3-15 h /500,000 btu 15-30 hp/1,000,000 btu 30-50 hp/1,750,000 btu 50+ h /1,750,000 btu Noise: Mechanical units need to be in compliance with the Tukwila Noise Code. Maximum permissible sound levels are based on from where the sound is created and where the sound is heard. Additionally, if sound can be heard from within a house at night in a residential zone it may not be allowed. For more details, see TMC 8.22 District of Sound Producing Source District of Receiving Property Residential, Daytime* Residential, Nighttime Commercial Industrial Residential 55 dB(A) 45 dB(A) 57 dB(A) 60 dB(A) Commercial 57 dB(A) 47 dB(A) 60 dB(A) 65 dB(A) Industrial 60 dB(A) 50 dB(A) 65 dB(A) 70 dB(A) *Daytime means 7AM-I OPM, Monday through Friday and 8AM-IOPM, Saturday, Sunday and State -recognized holidays. A few sounds are exempt from the noise code, including: Warning devices, Construction and property maintenance during the daytime hours (lam -I Opm); Testing of backup generators during the day. PERMIT APPLICATION NOTES - Value of construction — in all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the permit center to comply with current fee schedules. Expiration of plan review — applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The building official may grant one extension of time for additional periods not to exceed 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING k:�=OWNER OR AUTHORIZED AGENT: Signature: Date: Print Name: N'x &Y `o`r " Day Telephone: � +4 Mailing Addressyrl 50'+4-) kgyy-f''1-) S+ -v 5ewl t— 04 City State Zip H:\Applications\Forms-Applications On Line\2016 Applications\ivlechanical Permit Application Revised 14-16.docx Revised: January 2016 Page 2 of 2 bh DESCRIPTIONS PermitTRAK ACCOUNT QUANTITY PAID $221.32 M16-0058 Address: 45015 134TH PL Apn: 2613200045 $221.32 MECHANICAL $212.81 PERMIT ISSUANCE BASE FEE R000.322.100.00.00 0.00 $32.50 PERMIT FEE R000.322.100.00.00 0.00 $137.75 PLAN CHECK FEE R000.322.102.00.00 0.00 $42.56 TECHNOLOGY FEE $8.51 TECHNOLOGY FEE TOTAL FEES PAID BY RECEIPT: R8219 R000.322.900.04.00 0.00 $8.51 $221.32 Date Paid: Friday, April 15, 2016 Paid By: EVERGREEN REFRIGERATION Pay Method: CHECK 007852 Printed: Friday, April 15, 2016 11:15 AM 1 of 1 RWYS7EM5 QCs INSPECTION RECORD—]V ® v Retain a copy with permit 'v INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188n (206) 431-3670 Permit Inspection Request Line (206) 438-9350 I-0 aq � _ -("I Pr je [ d I'Mot Type of ' : `'t` Address: /3 Date Called: Special Instructions: 4Mj Date Wanted: a.m. `I % I -C p.m. R uest r Phone 1-06--16 7 Inspector: Date:S�— ff l7 I El REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. PERMIT COORD COPY PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: M16-0058 PROJECT NAME: 4501 BUILDING SITE ADDRESS: 4501 S 134TH PL X Original Plan Submittal Response to Correction Letter # DATE: 04/19/16 Revision #, Revision #, before Permit Issued after Permit Issued DEPARTMENTS: A7 Awc Lk-p,[� At/k A)lk 4-�-jp Building Division IN Fire Prevention I Planning Division ❑ Public Works ❑ Structural ❑ Permit Coordinator ❑ PRELIMINARY REVIEW: DATE: 04/21/16 Not Applicable ❑ Structural Review Required ❑ (no approval/review required) REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: DUE DATE: 05/19/16 Approved ❑ Approved with Conditions 19 Corrections Required ❑ Denied ❑ (corrections entered in Reviews) (ie: Zoning Issues) N REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: 12/18/2013 EVERGREEN REFRIGERATION I TC Page 1 of 3 Home t3 pafiol Contact Search L&I A-ZIndex Help Nly=t.,&I Safety & Health Claims & Insurance Workplace Rights Trades & Licensing Washington State Department of Lab©r & Industries EVERGREEN REFRIGERATION LLC Owner or tradesperson Principals PATTON, RODGER, PARTNER/MEMBER PATTON, MATTHEW, PARTNER/MEMBER Patton, Adam, PARTNER/MEMBER Patton, Douglas, PARTNER/MEMBER EVERGREEN REFRIGERATION LLC, PARTNER/MEMBER PATTON, DAVID, PARTNER/MEMBER (End: 01/21/2014) Doing business as EVERGREEN REFRIGERATION LLC 727 S KENYON ST SEATTLE, WA 98108 206-763-1744 KING County WA UBI No. Business type 602 512 953 Limited Liability Company Governing persons DAVID A PATTON MATTHEW PATTON; RODGER PATTON; License Verify the contractor's active registration / license / certification (depending on trade) and any past violations. ConstructionContractor Active. ....................................................... .. Meets current requirements. License specialties GENERAL License no. EVERGRL954R2 Effective — expiration 0110612006— 01/06/2018 Bond ................. Merchants Bonding Co (Mutual) $12,000.00 Bond account no. WA15097 Received by L&I Effective date 12/15/2011 01/01/2012 Expiration date Until Canceled Bond history Insurance ._........_..._............. Nationwide Mutual Ins Co $1,000,000.00 Policy no. ACP 3007246151 https://secure.Ini.wa.gov/verify/Detail.aspx?UBI=602512953&LIC=EVERGRL954R2&SAW= 5/13/2016 SCALE: NONE HVAC FLOOR PLAN SCALE: 1/8" =1'-0" y 1 ALL COMMISSIONING OF HEATING, VENTILATI❑N AND AIR CONDITIONING SYSTEMS AS REQUIRED BY SECTI❑N C408 'SYSTEM COMMISSIONING' OF THE 2012 WASHINGTON STATE ENERGY CODE (WSEC) SHALL BE PERFORMED BY EVERGREEN REFRIGERATION, LLC, THE ACTIVITIES TO BE ACCOMPLISHED ARE PER THE SECTIONS LISTED IN THE 'COMMISSIONING COMPLIANCE CHECKLIST' SHOWN BELOW. AT THE COMPLETION OF THE ACTIVITIES REQUIRED FOR COMMISSIONING AS DEFINED BY SECTI❑N C408 OF WSEC THE 'COMMISSIONING COMPLIANCE CHECKLIST' WILL BE REVIEWED WITH THE BUILDING OWNER OR THE OWNER'S REPRESENTATIVE AND THIS CERTIFICATION WILL BE SIGNED AND DATED, THIS WILL SATISFY TO THE CODE OFFICIAL THAT THE REPORT HAS BEEN ACCEPTED AS REQUIRED BY SECTION C408.1.2.1 OF WSEC. COMMISSIONING COMPLIANCE CHECKLIST FLEXIBLE DUCT Project Name: Project MANUAL VOLUME DAMPER Information Project Address: Commissioning Authority: 0 Commissioning 6�'fta Plan Commissioning Pian was used during construction and included items below w (Section 0408.1.1) • A narrative descrIPtion of acttvitles ori the persamet htended to accompUsb each are • ftswwe afterin for performance Q 16(� • Functions to be tested to Systems Balancing ® Systems Balancing has been completed (Section C408.2.2) SCALE: NONE HVAC FLOOR PLAN SCALE: 1/8" =1'-0" y 1 ALL COMMISSIONING OF HEATING, VENTILATI❑N AND AIR CONDITIONING SYSTEMS AS REQUIRED BY SECTI❑N C408 'SYSTEM COMMISSIONING' OF THE 2012 WASHINGTON STATE ENERGY CODE (WSEC) SHALL BE PERFORMED BY EVERGREEN REFRIGERATION, LLC, THE ACTIVITIES TO BE ACCOMPLISHED ARE PER THE SECTIONS LISTED IN THE 'COMMISSIONING COMPLIANCE CHECKLIST' SHOWN BELOW. AT THE COMPLETION OF THE ACTIVITIES REQUIRED FOR COMMISSIONING AS DEFINED BY SECTI❑N C408 OF WSEC THE 'COMMISSIONING COMPLIANCE CHECKLIST' WILL BE REVIEWED WITH THE BUILDING OWNER OR THE OWNER'S REPRESENTATIVE AND THIS CERTIFICATION WILL BE SIGNED AND DATED, THIS WILL SATISFY TO THE CODE OFFICIAL THAT THE REPORT HAS BEEN ACCEPTED AS REQUIRED BY SECTION C408.1.2.1 OF WSEC. COMMISSIONING COMPLIANCE CHECKLIST FLEXIBLE DUCT Project Name: Project MANUAL VOLUME DAMPER Information Project Address: Commissioning Authority: 0 Commissioning 0 Plan Commissioning Pian was used during construction and included items below w (Section 0408.1.1) • A narrative descrIPtion of acttvitles ori the persamet htended to accompUsb each are • ftswwe afterin for performance Q a • Functions to be tested Systems Balancing ® Systems Balancing has been completed (Section C408.2.2) • Alr and Hy*ork systems are prgwtb mtdy balanced In a manner to fMst r *,ke throttIN losses • Test ports are provided on each pump for neaslrhg pressure across the pjV ® HVAC Equipment Functional Testing has been completed (Section C408.2.3.1) Functional HVAC equipment has been tested to demonstrate the Installation and operation of components, systems and Testing system -by -system Interfacing relationships In accordance with approved plans and specifications ® HVAC Controls Functional Testing has been completed (Section C408.2.3.2) HVAC control$ hove bee tested to ens re that control devices are calibrated, ad�Jusnted an ep operate property. (Sections Sequence of operation hh ve been functionally tested to ensure they operate �n acc�roi"atnce wltali approved C408.2.3> nns an sec Ica ions ® Economizers Functional Testing has been completed (Section C408.2.3.3) Economizers operate in accordance with Manufacturer's specifications Supporting Documents Manuals, record documents and training have been completed or are scheduled (Section 0408.1.3.2) • System timmentation has been provided to the owner or schedled &tes • Record doaaients have been submFtted to ower or sr ted dater • TnMM has been completed or sclimMed motel Commissioning Report ® Preliminary Commissioning Report submitted to Owner and Includes items below (Section • Ddies fourd durhg teAM regAred by this section fth have not been corrected at the time of 0408.1.2) report preparation ' • Deferred tests, which cannot be perfwned at the the of report preperotbn due to dm* cwdtkwm ® I hereby certify that all requirements for Commissioning have been completed in accordance with the Washington State Energy Code, Certification Including all Items above. RAft Omer or NrWs Representative Date SEPAL! ATE PERAA IT FILE Copy PEQUI6ED FOS: Perllj�_ DMechanics'it DO a'�isctricat Fig nail; S;) i701!EI js subject to errors and cmi ED -Plumbing Plumbing "'si0n5. off 1 documents does not au�j�oi7�e ICLffas Piping f e a/Iela; W„� C any adopied code or ordinar'Ic:;. 9e, ipt City of Tukwila, �, I ir.l n, ct a sp :csid Copy andndjtICIs is ar-knowledged: DIVISION , By: Date: (3 City Of Tlukw, i1a BUILDING DIVISION _REVI3tONS No changes shall b dae mm a to the &CM of v/ork ivithout prior approval of u"01Ajila Building Division. V'0711 i v,siaris will require a new plan submittal and may include additional plan review fees, REVIEWED FOR CGDE COMPLIANCE APPROVED MAY0 5 201�6��/� A --t me - City of Tukwila BUILDING DIVISION GENERAL NOTES DUCTWORK 1.1 ALL DUCT DIMENSIONS ON PLAN ARE CLEAR INSIDE DIMENSIONS, ADD 2" TO EACH DIMENSION TO OBTAIN OUTSIDE DIMENSION. ADD 4"TO EACH DIMENSION IF DUCTWORK IS ON THE EXTERIOR OF BUILDING. 1.2 THE FIRST NUMBER ON ALL DUCT DIMENSIONS IS THE WIDTH AND THE SECOND NUMBER IS THE HEIGHT. 1.3 MATERIALS WITHIN DUCTS OR PLENUMS SHALL HAVE A FLAME SPREAD RATING LESSTHAN 25 AND A FLAME SMOKE DEVELOPMENT RATING LESS THAN 50, PER IMC 602.2.1. 1.4 SEAL ALL TRANSVERSE JOINTS FOR DUCTWORK WITH STATIC PRESSURE BETWEEN 1/2 INCHES AND 2 INCHES. DUCTWORK WHICH IS DESIGNED TO OPERATE AT PRESSURES ABOVE 1/2 INCH WATER COLUMN STATIC PRESSURE SHALL BE SEALED IN ACCORDANCE WITH STANDARD RS -7. 1.5 ALL DUCT GAUGES PER SMACNA, IMC 603-4. 1.6 ALL DUCT SUPPORTS PER SMACNA, IMC 603-10. 1.7 ATTACH DIFFUSERS AND GRILLES TO T -BAR GRID PER WA STATE & LOCAL CODES. 1.8 BALANCING DAMPERS ARE TO BE INSTALLED ON ALL BRANCH DUCTS OR DIFFUSERS. 2.1 INSULATE OR LINE DUCTWORK PER WA. STATE ENERGY AND MECHANICAL CODES. 2.2 INSULATE REFRIGERANT & CONDENSATE PIPING PER STATE & LOCAL ENERGY CODES. GENERAL CONTRACTOR 3.1 GENERAL CONTRACTOR TO PROVIDE AND CUT OPENINGS FOR ALL ROOFTOP, CEILING, FLOOR, AND WALL PENETRATIONS, INCLUDING WEATHERPROOF SEALING AND FIRE PROOF LINING PER IMC & IBC. 3.2 GENERAL CONTRACTOR TO VERIFY PENETRATION LOCATION AND DIMENSIONS WITH ERL BEFORE FRAMING OPENINGS. 3.3 GENERAL CONTRACTOR TO PROVIDE ALL DEMOLITION, PATCHING, AND PAINTING AS REQUIRED FOR MECHANICAL WORK. 3.4 GENERAL CONTRACTOR TO PROVIDE ADEQUATE STRUCTURAL SUPPORT AS REQUIRED FOR MECHANICAL WORK 3.5 GENERAL CONTRACTOR TO PROVIDE ADEQUATE ENGINEERING AS REQUIRED FOR MECHANICAL WORK. 3.6 GENERAL CONTRACTOR TO PROVIDE SERVICE ACCESS PER CODE TO ALL MECHANICAL EQUIPMENT. 3.7 GENERAL CONTRACTOR TO LEVEL ALL FACTORY CURBS PROVIDED BY ERL PROVIDE ALL CANT STRIPS AND CURB INSULATION, AND SEAL AGAINST LEAKS. 3.8 GENERAL CONTRACTOR TO PROVIDE ALL CUTTING AND PATCHING OF T -BAR CEILING AS REQUIRED FOR HVAC INSTALLATION. 3.9 GENERAL CONTRACTOR TO PROTECT ALL OPENINGS THROUGH FLOORS PROVIDED FOR DUCTWORK INSTALLATION IN ACCORDANCE WITH TABLE 601 OF INTERNATIONAL BUILDING CODE, WHERE REQUIRED BY SECTION 707 OF IBC. ELECTRICAL 4.1 ERL TO INSTALL ALL LOW VOLTAGE CONTROL WIRING, CONDUIT WILL BE PROVIDED BY ELECTRICAL CONTRACTOR. 4.2 ELECTRICAL CONTRACTOR TO PROVIDE ALL ELECTRICAL CONNECTIONS, DISCONNECTS, AND STARTERS FOR MECHANICAL EQUIPMENT. 4.3 ELECTRICAL CONTRACTOR TO VERIFY EQUIPMENT SIZES, LOADS AND LOCATIONS WITH ERL MECHANICAL PLAN AND WITH FIELD CONDITIONS. 4.4 ELECTRICAL CONTRACTOR TO INTERLOCK BATHROOM EXHAUST FANS WITH LIGHT SWITCH. 4.5 ERL TO PROVIDE 7 -DAY NIGHT SETBACK, PROGRAMMABLE TYPE T -STAT WITH CAPABILITY OF 5'F DEADBAND. 4.6 ERL TO VERIFY FINAL LOCATION OF THERMOSTAT WITH CUSTOMER. 4.7 ELECTRICAL CONTRACTOR TO PROVIDE ELECTRICAL GCFI OUTLET WITHIN 25 FT OF EACH PIECE OF MECHANICAL EQUIPMENT. PLUMBING 5.1 PLUMBING CONTRACTOR TO FURNISH AND INSTALL ALL GAS PIPING FOR MECHANICAL EQUIPMENT PER CODE. 5.2 PLUMBING CONTRACTOR OFFSET VENTS 10 FEET MINIMUM FROM ALL HVAC FRESH AIR INTAKES OR 2' ABOVE HIGHEST POINT OF INTAKE, IMC 401.4.1. 5.3 CONDENSATE DRAINS FROM RTU BY ERI TO DRAIN WITHIN 12" OF UNIT. CONDENSATE DRAINS FOR AIR HANDLERS BY PLUMBER. ENERGY CODE COMPLIANCE 6.1 AT A MINIMUM, EACH FLOOR IS TO BE CONSIDERED A SEPARATE ZONE. VERIFY THERMOSTATIC CONTROL FOR EACH ZONE AS INDICATED ON PLANS. 6.2 OUTSIDE AIR INTAKES, EXHAUST OUTLETS, AND RELIEF OUTLETS SERVING CONDITIONED SPACES SHALL BE EQUIPPED WITH DAMPERS WHICH CLOSE AUTOMATICALLY WHEN THE SYSTEM IS OFF OR UPON POWER FAILURE, PER WSEC SFC (4024.5.4 6.3 AIR ECONOMIZERS WHERE REQUIRED BY CODE ARE INDICATED BY THE EQUIPMENT SCHEDULE AT 100% CAPABILITY, CONTROL AND OPERATION OF THE ECONOMIZER SHALL COMPLY WITH WSEC SEC. C403.4.1 MECHANICAL CODE COMPLIANCE 7.1 WHERE REQUIRED PROVIDE AUTOMATIC SHUTOFF ACTIVATED BY SMOKE DETECTORS IN EACH SYSTEM DELIVERING HEATING OR COOLING AIR IN EXCESS OF 2000 CFM. DETECTORS SHALL BE LOCATED IN THE MAIN RETURN AIR PER IMC 606. WA2012 SYMBOL LEGEND SYMBOL ABBY. DESCRIPTION ® DUCT SECTION SUPPLY ® DUCT SECTION - RETURN/EXHAUST 14'x8' RECTANGULAR DUCT 14' ROUND DUCT FLEXIBLE DUCT MVD MANUAL VOLUME DAMPER ❑BDD BDD BACKDRAFT DAMPER MD MOTORIZED DAMPER FD I FIRE DAMPER -� FSD FIRE/SMOKE DAMPER 020V POWER REQ.) -�-o CEILING RADIATION DAMPER sn SD SMOKE DETECTOR TQ T THERMOSTAT QS S SENSOR -R----R R I REFRIGERANT LINES -G- - - -G G NATURAL GAS LINES ® CEILING DIFFUSER (SUPPLY) ® CEILING DIFFUSER (RETURN/EXHAUST) D EXHAUST FAN (CEILING MOUNTED) u� u INLINE FAN PROPELLER FAN SIDEWALL DIFFUSER DUCT FITTING __ ZD I ZONE t M 00 M N U Q CiJ NOT PUBLISHED. ALL RIGHTS RESERVED. THE DRAWING AND SPECIFICATIONS, IDEAS. DESIGNS AND ARRANGEMENTS REPRESENTED THEREBY ARE AND SHALL REMAIN THE PROPERTY OF EVE- RGREEN REFRIGERATION INC. NO PART THEREOF SHALL BE REPRODUCED. COPIED, ADAPTED. DISC- LOSED OR DISTRIBUTED TO OTHERS, SOLD, PUB- LISHED OR OTHERWISE USED WITHOUT THE PRIOR WRITTEN CONSENT 13F AND APPROPRIATE COMPEN- SATION TO EVERGREEN REFRIGERATION INC. VISUAL CONTACT WITH THE ABOVE DRAWINGS OR SPECIFIC- ATIONS SHALL CONSTITUTE CONCLUSIVE EVIDENCE OF ACCEPTANCE OF THESE RESTRICTIONS. .o •o 0 0 w w w Q Q a H Z W d O W W 0 Z 0 U) W 0 IN Z O 0 D Z O O L+_ D W (n 0 u La co co r J CO L C Q w Q __J o� .t DWG. BY: GN CHK. BY: MG JS JOB NO.: 416060