MECHANICAL PERMIT
Parcel No: 2623049101 Permit Number: M16-0062
Address: 1002 ANDOVER PARK E Issue Date: 5/26/2016
Permit Expires On: 11/22/2016
Project Name: PRICECO
Owner:
Name: 1006 ANDOVER ASSOCIATES
Address: 5851 S 194TH ST C/O CABLE
MANAGEMENT, KENT, WA, 98032
Contact Person:
2012
Name: JIM DIDLAKE
Phone: (206) 473-9914
Address: 420 37 ST SUITE H, AUBURN, WA,
2012
98001
2014
Contractor:
2012
Name: BUDGETHVACUS LLC
Phone: (206) 473-9914
Address: 420 37 ST NW #1, AUBURN, WA,
2012
98001
2012
License No: BUDGEL*882B7
Expiration Date: 1/28/2018
Lender:
Name:
Address:
DESCRIPTION OF WORK:
REIISUANCE OF EXPIRED PERMIT M15-0050
REPLACE EXISTING 40 YEAR OLD 2.5 TON A/C UNIT WITH ELECTRIC HEAT WITH A NEW HIGH EFFICIENCY 2 TON
HEAT PUMP. REPLACE GAS UNIT HEATER IN WAREHOUSE.
Valuation of Work: $15,000.00
Fees Collected: $389.62
Type of Work: REPLACEMENT
Electrical Service Provided by: PUGEST SOUND ENERGY
Fuel type: ELECT
Water District: TUKWILA
Sewer District: TUKWILA
Current Codes adopted by the City of Tukwila:
International Building Code Edition:
2012
National Electrical Code:
2014
International Residential Code Edition:
2012
WA Cities Electrical Code:
2014
International Mechanical Code Edition:
2012
WAC 296-46B:
2014
Uniform Plumbing Code Edition:
2012
WA State Energy Code:
2012
International Fuel Gas Code:
2012
Permit Center Authorized Signature: I A )A X X' kJ Date: J � lO — I
I hearby certify that I have read and examined this permit and know the same to be true and correct. All
provisions of law and ordinances governing this work will be complied with, whether specified herein or not.
The granting of this permit does not presume to give authority to violate or cancel the provisions of any other
state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this
development perm. and agree to the conditions attached to this permit.
Signature Date:
Print Na e7:::y-b
This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if
the work is suspended or abandoned for a period of 180 days from the last inspection.
PERMIT CONDITIONS:
1: Work shall be installed in accordance with the approved construction documents, and any changes made
during construction that are not in accordance with the approved construction documents shall be
resubmitted for approval.
2: All permits, inspection record card and approved construction documents shall be kept at the site of work
and shall be open to inspection by the Building Inspector until final inspection approval is granted.
3: All construction shall be done in conformance with the Washington State Building Code and the
Washington State Energy Code.
4: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap
the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks,
wells, and other excavations. Final inspection approval will be determined by the building inspector based
on satisfactory completion of this requirement.
5: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the
City of Tukwila Building Department (206-431-3670).
6: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila
Permit Center.
7: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an
approval of, any violation of any of the provisions of the building code or of any other ordinances of the City
of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other
ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction
documents and other data shall not prevent the Building Official from requiring the correction of errors in
the construction documents and other data.
8: ***MECHANICAL PERMIT CONDITIONS***
9: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila
Permit Center (206/431-3670).
10: Manufacturers installation instructions shall be available on the job site at the time of inspection.
11: Readily accessible access to roof mounted equipment is required.
14: Sprinkler coverage around unit heaters needs to comply with section 8.3.2.5 and figure 8.3.2.5 of NFPA 13
(2013 edition).
12: All new sprinkler systems and all modifications to existing sprinkler systems shall have fire department
review and approval of drawings prior to installation or modification. New sprinkler systems and all
modifications to sprinkler systems involving more than 50 heads shall have the written approval of Factory
Mutual or any fire protection engineer licensed by the State of Washington and approved by the Fire
Marshal prior to submittal to the Tukwila Fire Prevention Bureau. No sprinkler work shall commence
without approved drawings. (City Ordinance No. 2436).
13: Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (City Ordinances
#2436 and #2437)
15: Any overlooked hazardous condition and/or violation of the adopted Fire or Building Codes does not imply
approval of such condition or violation.
16: These plans were reviewed by Inspector 511. If you have any questions, please call Tukwila Fire Prevention
Bureau at (206)575-4407.
PERMIT INSPECTIONS REQUIRED
Permit Inspection Line: (206) 438-9350
1400
FIRE FINAL
0703
MECH EQUIP EFF
1800
MECHANICAL FINAL
0609
PIPE/DUCT INSULATION
0705
REFRIGERATION EQUIP
0701
ROUGH -IN MECHANICAL
CITY OF TUKWILA
Community Development Department
Permit Center
• 6300 Southcenter Blvd., Suite 100
Tukwila, WA 98188
http://www.TukwilaWA.gov
SITE LOCATION
Mechanical Permit No.
Project No. �►-�t
Date Application Accepted:
Date Application Expires:
Tor office use only)
MECHANICAL PERMIT APPLICATION
Applications and plans must be complete in order to be accepted for plan review.
Applications will not be accepted through the mail or by fax.
"please print"
King Co Assessor's Tax No.:
Site Address: 1 6 ® 7 o<
C'-
- � N Lkt C,�
Suite Number:
Floor:
Tenant Name: iii 1 cc
New Tenant:
.....Yes ❑ ..No
PROPERTY OWNER
Name: L S TZ Ptd Q C re -t- 1S'
Address�A,.1 1 5L4 . K -r-t-
City: P, -4z y"y —, State: (-rA
Zip- j ��
CONTACT PERSON - person receiving all project
communication
Name,
•1 M bibL,
Address:
City: St Zip:
Phone: Fax:
Email: -:Tl 1VI a t i T H VAC .0 S -
MECHANICAL CONTRACTOR INFORMATION
Company Name: V .S
Address:
City: ki OL) a�� State: Zipcq�66
Phone:
Contr Reg No.: 6 6., _ I C _ 9,?Exp Dat-• - + . 3 1
Tukwila Business License No.:
L'I'B
Valuation of project (contractor's bid price): $—L47
47
Describe the scope of work in detail: y C f:6 /A 0 , Af C CV -Y71 C,6' A /� 0 r,- 0 -�Z
Use: Residential: New .......... ❑ Replacement ........ ❑
Commercial: New .......... ❑ Replacement ......y
Fuel Type: Electric...., Gas ....... N� Other:_
H:Wpplications\Forms-Applications On Line\2011 ApplicationsWechanical Permit Application Revised 8-9-1 Ldocx
Revised: August 2011
Page 1 of 2
ZA
Indicate type of mechanical work being installed and the quantity below:
Unit Type
Qty
Furnace <100k btu
Furnace >I 00k btu
Floor furnace
Suspended/wall/floor
mounted heater
1
Appliance vent
Repair or addition to
heat/refrig/cooling
system
Air handling unit
<I0,000 cfm
Unit Type
Qty
Air handling unit
>I0,000 cfm
Evaporator cooler
Ventilation fan
connected to single duct
Ventilation system
Hood and duct
Incinerator — domestic
Incinerator —
comm/industrial
Unit Type Qty
Fire damper
Diffuser
Thermostat
Wood/gas stove
Emergency enerator
Other mechanical
equipment
Boiler/Compressor Qty
0-3 hp/100,000 btu
3-15 h /500,000 btu
15-30 hp/1,000,000 btu
30-50 hp/1,750,000 btu
50+ h /1,750,000 btu
I PERMIT APPLICATION NOTES - I
Value of construction — in all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject
to possible revision by the permit center to comply with current fee schedules.
Expiration of plan review — applications for which no permit is issued within 180 days following the date of application shall expire by limitation.
The building official may grant one extension of time for additional periods not to exceed 90 days each. The extension shall be requested in writing
and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition).
I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER
PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT.
BUILDING OWNER OR AUTHORIZED AGENT: p %
Signature: Date.
Print Name: --:S-1 Day Teleph
oone
t: -"
Mailing Address: a'� ' a �� f'`f 3 . j Q igU z� , W A 1
City State Zip
H:\Applications\Forms-Applications On Line\2011 ApplicationsWechanical Permit Application Revised 8-9-1 Ldocx
Revised: August 2011 Page 2 of 2
hh
DESCRIPTIONS
PermitTRAK
1
$314.69
M16-0062 Address: 1002 ANDOVER PARK E
Apn: 2623049101
$314.69
MECHANICAL
$299.70
PERMIT ISSUANCE BASE FEE
R000.322.100.00.00 0.00
$32.50
PERMIT FEE
R000.322.100.00.00 0.00
$267.20
TECHNOLOGY FEE
$14.99
TECHNOLOGY FEE
TOTAL FEES ..ID BY RECEIPT:.. 586
ROOO.322.900.04.00 0.00
$14.99
$314.69
Date Paid: Thursday, May 26, 2016
Paid By: BUDGETHVACUS LLC
Pay Method: CREDIT CARD 151040
Printed: Thursday, May 26, 2016 3:15 PM 1 of 1
SYSTEMS
Date Paid: Friday, April 22, 2016
Paid By: BUDGETHVAC US LLC
Pay Method: CREDIT CARD 153509
Printed: Friday, April 22, 2016 11:30 AM 1 of 1 I!r�rif1
SY57EM5
r—
INSPECTION RECORD
Retain a copy with permit��
INSPECTION NO. PERMIT NO.
CITY OF TUKWILA BUILDING DIVISION
6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670
Permit Inspection Request Line (206) 438-9350
P'ect�
N C--Pe�
Type of Inspection:
�.
Address: �{� 1p�
' 1 �+�)VL1
I `
t`�i�
1
Date Called:
S ecial Instructions:
Date Wagted: a.m.
�j �1 p.m.
Requester:
Phone No:
Approved per applicable codes. a Corrections required prior to approval.
COMMENTS:
® q. cc
e
IInspector: IDate:
'6 — o
REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be
paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection.
MVICWFD FOR
:ODS COMPLIANCE
�,IAY 0 5 2016
i
d
City of T uWjila
' UlL.DING DIVISION
Dai®:
Qiy of 'i ul:,fila
BOWING DIVISION
t4l &**- 00 & 2
RECEIVED
CITY OF TUKWILA
APR 22 20%
PERMIT CENTER
3902 W Valley Hwy. N, Ste. #409
Auburn, WA 98001
Project /0 C
Job # Date
By L E_
Page Of
rlL
R
—EAVPIEPWROE'VVEE
DDO
RC
ECODE COMPLIAN
MAY 0 5 2016
Cib� of Trukwiwil a
<(
Vv
LBUICILDIN91VISION
DIVISION
L
75Z. &j -r cl &i L,-:rrIA
A-V I
A
..... CITY OF TUKWILA
APR 22 2016
PERMIT CENTER
/VFW
Submittal
kcA-r puvvw
ff--1 E =
Single Packaged Heat Pump
14 SEER Convertible
4WCC4024A1000A
RECEIVED
CI -FY OF TUKWIL A
APR 22 2016
PERMIT CENTER
t4l b- 00(92
0
REViEVVED FOR
C01)E COMPLIAMCE
uavau
MAY 0 5 2016
is
City U-,-uf'.r'ms'
BUILDIWG DIVI
Note: "Graphics in this document are for representation only. Actual
model may differ in appearance."
TAG
Only qualified personnel should install and service the equipment. The installation, starting up, and servicing of heating, ventilating, and
air-conditioning equipment can be hazardous and requires specific knowledge and training. Improperly installed, adjusted or altered
equipment by an unqualified person could result in death or serious injury. When working on the equipment, observe all precautions in the
literature and on the tags, stickers, and labels that are attached to the equipment.
October 2014 4WCC4024A-SUB-1A-EN CR7ingersol►Rand
Product Specifications
MODEL
4WCC4024A1000A
RATED Volts/PH/Hz
208-230/1/60
Performance Cooling BTUH (a)
24600
Indoor Airflow (CFM)
758
Power Input (KW)
1.9
EER/SEER (BTU/Watt-Hr.) (b)
12.00 / 14.00
Sound Power Rating [dB(A)] W
66.4
PERFORMANCE HEATING
CONSTANTTORQUE ECM
(High Temp.) BTUH
22000
Power Input (KW)
1.8
(Low Temp.) BTUH
14300
Power Input (KW)
1.12
HSPF (BTUH/Watt-Hr)
8.0
POWER CONN. —V/Ph/Hz
208-230/1/60
Min. Brch. Or. Ampacity (d)
19.4
Fuse Size — Max. (amps)
30
Fuse Size — Recmd. (amps)
30
COMPRESSOR
SCROLL
VOLTS/PH/HZ
208-230/1/60
R.L. Amps — L.R. Amps
12.8/58.3
OUTDOOR COIL — TYPE
SPINE FIN
Rows/F.P.I
2/24
Face Area (sq. ft.)
13.32
Tube Size (in.)
3/8
Refrigerant Control
EXPANSION VALVE
INDOOR COIL — TYPE
PLATE FIN
Rows/F.P.I
3/15
Face Area (sq. ft.)
3.5
Tube Size (in.)
3/8
Refrigeration Control
EXPANSION VALVE
Drain Conn. Size (in.)
3/4 FEMALE NPT
N -C 1
c.E-;:� —i, ku —t
N <DFt I Z 4 J�
OUTDOOR FAN — TYPE
SWEPT
DIA. (IN.)
23.4
DRIVE/NO. SPEEDS
DIRECT/ 3
CFM @ 0.0 in. w.g. (e)
2550
Motor — HP/R.P.M
1/12/850
Volts/Ph/Hz
208-230/1/60
F.L. Amps/L.R Amps
.54/.82
INDOOR FAN — TYPE
CONSTANTTORQUE ECM
Dia. x Width (in.)
10.62 X 10.68
Drive/No. Speeds
DIRECT/ 3
CFM @ 0.0 in. w.g. M
SEE FAN PERF TABLE
Motor— HP/R.P.M.
1/3/1050
Volts/Ph/Hz
208-230/1/60
F.L. Amps
2.8
FILTER/FURNISHED
NO
Type Recommended
THROWAWAY
Recmd. Face Area (sq. ft) (g)
2.7
REFRIGERANT
R-410
Charge (lbs.)
5.74
CHARGING SPECIFICATIONS
Subcooling
16°
DIMENSIONS
H X D X W
Crated (in.)
46 X 45 X 52
WEIGHT
Shipping (lbs.) / Net (lbs.)
40f/ 328
(a) Rated in accordance with AHRI Standard 210/240.
(b) Rated in accordance with D.O.E. test procedure. ,
(0 Sound Power values are not adjusted for AHRI 270-95 tonal '
corrections.
(d) Calculated in accordance with currently prevailing Nat1 Electrical
Code.
(e) Standard Air — Dry Coil — Outdoor.
M Standard Air — Dry Coil — Indoor
(g) Filters must be installed in return air stream. Square footages listed
are based on 300 f.p.m. face velocity. If permanent filters are used
size per manufacturer's recommendation with a clean resistance of
0.05" W.C.
Z �$S
3(s
3 C -( L �Z 041. 'iarTC<1
2 4WCC4024A-SU B-1 A-E N
Outline Drawings
0
0
79.50 -
[3-1/81
398.22
115-II/161
(OUTS IDEI
Figure 2. 2 - 3 TON MODELS
296.62
[II-II/16]
(OUTSIDE)
ec�.b 58. 19
RETURN 12-9/321
177.55
SUPPLY [71
398.22
[15-11/16]
(OUTSIDE)
176.07
[6-15/161
17.78
(11/161
SECTION X -X
TYPICAL (8) SIDES OF SIDEFLOW DUCT OPENINGS
(45-1/21
(SURFACE AREA)
BACK SIDE
9
/81
4 4WCC4024A-SUB-IA-EN
Height MM/IN
APPROX. CORNER WEIGHT
SHIPPING
TOTAL
CENTER OF GRAVITY
Model
KG / LBS
UNIT
MM/IN.
A
W1
W2
W3
I W4
B
C
KG / LBS
WIGHT
KG / LBS
4TCC4024
898.53 [35-3/8]
58.3
129
36.8 [81]
26.1
[58]
41.0
[901
196.1
432
162.4
358
479.8 [18.9]
527.8 [20.8]
61.3
27.5
43.1
204.8
171.1
4TCC4030
135
38'7 [85]
[61]
[95]
451
377
406.5 [16.0]
594.1 [23.4J
4TCC4036
949.33 [37-3/8]
61.7
136
38.9 [86]
27.7
[61]
43.7
[96]
205.7
453
172.0
379
414.3 [16.3]
697.6 [27.5]
52.9
24.1
38.3
182.3
148.6
4WCC4024
117
33.3 [731
[53]
[84]
402
328
430 [16.9]
565.3 [22.3]
4WCC4030
55.3
50.3 [110]
16.6
39.2
195.0
161.3
413.5 [16.3]
581 [22.9]
1050.93 [41-3/8]
122
[37]
[86]
430
355
4WCC4036
59.6
[1311
37'3 [821
26.6
[59]
41.7
[92]
199.0
439
1 165.3
364
430 [17.0]
535 [21.1]
4 4WCC4024A-SUB-IA-EN
304.80
[121
(INS IDEI
75.41
[2-31/321
Outline Drawings
Figure 3. 2 — 3 TON MODELS
RECOMMENDED SERVICE CLEARANCE MM/IN.
WITH ECONOMIZER
BACK SIDE 304.8 1121 762.0 (301
LEFT SIDE 762.0 1301 914.4 1361
RIGHT SIDE 609.6 1241
FRONT SIDE 1066.8 (42)
CLEARANCE TO COMBUSTIBLE
MATERIAL MM/1N.
BOTTOM
0
BACK SIDE
25.4
111
LEFT SIDE
152.4
161
RIGHT SIDE
152.4
161
FRONT SIDE
304.8
(121
TOP
914.4
[361
359.79
[14-5/321
24V ENTRY
288.42 225'68
111-III/321 [8-7/81
117.73
[4-5/81
85.22
[3-11/321
[161,,
( I No I DE 1 t;UTTOM DUCT OPENINGS
�-•- 128.08
15-1/321
RIGHT SIDE
73.46
6-21/321
406.40
[161
(INSIDE)
.89
5/81
POWER ENTRY
28.58 (1-1/8) DIA. KNOCKOUT
—POWER ENTRY
28.58 11-1/81 DIA. KNOCKOUT
34.93 11-3/81 DIA. KNOCKOUT
\50.01 11-31/321 DIA. KNOCKOUT
`—SINGLE POINT ENTRY
34.93 [1-3/81 DIA. KNOCKOUT
50.01 11-31/321 DIA. KNOCKOUT
62.71 [2-15/321 DIA. KNOCKOUT
4WCC4024A–SU Bi -1 A -EN 5
Supplementary Electric Heater
Table 3. BAYHTRV — Supplementary Electric Heaters
Table 4. BAYSPEK — Single Power Entry Kit
SINGLE CIRCUIT POWER AMPACITY AND OVER CURRENT PROTECTION
ELECTRIC
RATED
HEATER MODEL
MIN CKT AMP
HEATER
NO.
KW/STAGE
BAYHTRV105
MAX. FUSE
CANADA
UNIT
HEATER
VOLT-
PHASE
AMPS
CAPACITY
OF
MCA
OR HACR
ONLY MAX.
MODEL
MODEL
AGE
STAGES
CKT BKR
CKT BKR
Kyy
BTUH
1
2
SIZE
SIZE
4024-4060
BAYHTRV105
208/240
1
18/21
3.76/5.0
8 00/
1
3.70/
-
23/26
25/30
25/30
1
4024-4060
BAYHTRV108
208/240
1
29/33
6.0/8.0
20500/
1
6.0/
-
36/41
40/45
40/45
27300
8.0
4024-4060
BAYHTRV110
208/240
1
36/42
7.5/10.0
1
-
45/52
45/60
45/60
34100/
10.0
4030-4060
BAYHTRV115
208/240
1
54/63
11.27/
38500/
2
7.5/
3.76/
68/78
70/80
70/80
15.0
51200
10.0
5.0
4042-4060
BAYHTRV120
208/240
1
72/83
15.0/
51200/
2
7.5/
7.5/
90/
90/110
90/110
20.0
68300
10.0
10.0
104
4042-4060
BAYHTRV125
208/240
1
90/
18.78/
64100/
2
11.26/
7.5/
113/
125/150
125/150
104
25.0
85300
15.0
10.0
130
Table 4. BAYSPEK — Single Power Entry Kit
SINGLE CIRCUIT POWER AMPACITY AND OVER CURRENT PROTECTION
UNIT MODEL
SINGLE POWER
ENTRY KIT
HEATER MODEL
MIN CKT AMP
MAX OVER -CURRENT DEVICE
4WCC4024A
BAYSPEK60
BAYHTRV105
45
50
BAYHTRV108
60
60
BAYSPEK62
BAYHTRV110
71
80
4WCC4024A-SUB-IA-EN
Optional Equipment — Filter Rack
Optional Equipment — Economizer
Table 5. BAYECON101,102A Down Discharge Economizer and Rain Hood
(Mounts Over Horizontal Return Air Opening)
HVAC Unit
Economizer
Economizer
Unit Application
Models
Economizer
rain hood ao�'0000000'�`
A
BAYECON101A
4024-036
Outside air
C p
'
Gaskets (2)
dampers
1 E
�--- Rain Hood
Return air
Mixed Air
dampers Required
Sensor
cfilter kit, order
Models
Mist separately
B
C
eliminator
0
E
F
BAYECON200AA
BAYECON102A
4042-060
Relief Return
20"
16-7/8"
damper Duct
11-11/16"
15"
Roofcu rb
4042-4060
Table 6. BAYCON200, 201A Horizontal Economizer and Rain Hood
Note: The drawings on this page are prepared by the manufacturer in order to provide detail regarding job layout only. These drawings are not
intended to be used as a basis to construct, build or modify the items depicted in the drawings. The manufacturer is not responsible for
the unauthorized use of these drawings and expressly disclaims any liability for damages resulting from such unauthorized use.
4WCC4024A-SUB-IA-EN
Economizer
A
C p
'
Gaskets (2)
Duct
1 E
�--- Rain Hood
Mixed Air
Sensor
Economizer
Models
A
B
C
D
E
F
BAYECON200AA
4024-4036
22"
20"
16-7/8"
15-11/16"
11-11/16"
15"
BAYECON201AA
4042-4060
26"
22-21/32"
19"
17-11/16"
14-11/16"
21-3/8"
Note: The drawings on this page are prepared by the manufacturer in order to provide detail regarding job layout only. These drawings are not
intended to be used as a basis to construct, build or modify the items depicted in the drawings. The manufacturer is not responsible for
the unauthorized use of these drawings and expressly disclaims any liability for damages resulting from such unauthorized use.
4WCC4024A-SUB-IA-EN
COIL
EVAPORATOR
COIL _
URN AIR
ALUMINIZED
D STEEL
,HUTIEKCHANGER
HORIZONTAL
SUPPLY AND
./ RETURN OPTION
TON COOLING AND HEATING/COOLING UNITS
GASKETED ACCESS
PANELS WITH
QUICK -RELEASE
LATCHES AND
LIFTING HANDLES
RECEIVED
CITY OF TUKWILA
APR 221016
PERMIT CENTER
ALUMINIZED STEEL
GAS-FIRED
HEAT EXCHANGER
EVAPORATOR
COIL
A;NI naN
SUPPLY AIR SYSTEM COMPRESSOR CD
- --
24TON COOLING ONLY 2Y,4 TON HEATING/COOT�"' TYN6F:
MECHANICAL SPECIFICATIONS
GENERAL -All units are factory assembled, piped, internally
wired and fully charged with R-22. All, units are designed to
operate at outdoor ambient temperatures as high as 120° F.
2-10ton units certified by ARI Standard 210 and 270. National
Rating Standard of the Air Conditioning and Refrigeration
Institute. SFCAtSFHA Heating/Cooling units design is cer-
tified by American Gas Association (A.G.A.) specificai y for
outdoor applications using propane or natural gas. All Cool-
F__
ool
TRITIOAVINd
-
rr-
5-1'5 TON NEATING/COOLinG (SOCA) AND COOLING (SACA)
UNITS
CASING — All access panels are Basketed and provided with
fasteners and handles. One inch, one pound density foii-
faced glass fiber insulation is on heat exchanger section .
(SOCA units). Same composition mat -faced insulation is in
evaporator section.
Ing Units are Underwriters' Laboratories listed. All units are
designed for outdoor rooftop or ground level installation. REFRIGERATION CONTROLS — Refrigeration controls include
Exterior surfaces of all units are phosphatized, zinc -coated -condenser fan, evaporator fan and compressor contactors,
steel with epoxy resin primer and gray -green baked enamel and 24 volt transformer. Safety controls include high and low
finish. All 2-15 ton Horizontal units have welded shell, 3600 Pressure controls, (except 5 ton), winding thermostat and
_RPM compressors. compressor overloads. Cycle guard prevents unit cycting on
overloads and safety controls to be reset at thermostat inside
the building. Each circuit of the unit has a separate set of
0 O i•. refrigeration controls. (10-16 has 2 independent circuits).
}
DIMENSIONS ® SARA 2.4 f
34 N.P.T.
1 DRAIN CONN.'NOTE: Supply return casing for 3 and 4 ton only.
"C" lDIA. K.O.
ELECT. HEAT CONN. '01SUPPLY-RETURN
1
357/9 60 � CASING
9 1,/4
FIGURE 14.1 34 1'>�
31/A2 131h
a1
111/4V2 LQ)
25� 1 A
( 19T/e '/e K.D. ELECT. CONN. ECONOMIZER
OUTSIDE
`� PIPE SUPPORTS
CENTERED FIELD SUPPLIED
FIGURE 14.2
SIDE VIEW ��(�END-VIEW{j
1- R { F
E
41/4
FIGURE 14-1 Page 14 — SAHA Unit 2040 f
Unit Dimensions
SARA
20
25
30
40
A
13%
16%
20%
28'y/e
B
123.14
15%
19
25'A
C
t ie
13A
2
2
Net Wt.
300
320
356
454
IC 4,
FIGURE 14-2 Page 14 -- Clarification of Cot Away
SARA
2025
1
30
40
H
9z
OUTSIDE AIR HOOD
39%
47%
A
�
L
10%
23
313.0
B
j
17%
201/4 1
24
3234
TABLE 14-1- Net Weiahts
ACCESSORY NET WEIGHTS
SUPPLY RETURN CASING
960
RELIEF DAMPER
15
ECONOMIZER
9z
OUTSIDE AIR HOOD
56
ROOF CURB
56
CONCENTRIC DUCT
60
t.t%/ _` AIR HOOD
V16%
DAMPER ,�
f
i
1112 1 3
i I
14
STRIP
11/1/2016
City of Tukwila Allan Ekberg, Mayor
Department of Community Development Jack Pace, Director
JIM DIDLAKE
420 37 ST SUITE H
AUBURN, WA 98001
RE: Permit No. M16-0062
PRICECO
1002 ANDOVER PARK E
Dear Permit Holder:
In reviewing our current records, the above noted permit has not received a final inspection by the City of Tukwila Building
Division. Per the International Building Code, International Mechanical Code, Uniform Plumbing Code and/or the National Electric
Code, every permit issued by the Building Division under the provisions of these codes shall expire by limitation and become null
and void if the building or work authorized by such permit has not begun within 180 days from the issuance date of such permit, or if
the building or work authorized by such permit is suspended or abandoned at any time after the work has begun for a period of 180
days. Your permit will expire on 12/7/2016.
Based on the above, you are hereby advised to:
1) Call the City of Tukwila Inspection Request Line at 206-438-9350 to schedule for the next or final inspection. Each
inspection creates a new 180 day period, provided the inspection shows progress. .
-or-
2) Submit a written request for permit extension to the Permit Center at least seven(7) days before it is due to expire.
Address your extension request to the Buildin21
g Official and state your reason(s) for the need to extend your permit.
The Building Code does allow the Building Official to approve one extension of up to 180 days. If it is determined that your
extension request is granted, you will be notified by mail.
In the event you do not call for an inspection and/or receive an extension prior to 12/7/2016, your permit will become null and void
and any further work on the project will require a new permit and associated fees.
Thank you for your cooperation in this matter.
Sincerely,
Bill Rambo
Permit Technician
File No: M16-0062
6300 Southcenter Boulevard Suite#100 • Tukwila, Washington 98188 9 Phone 206-431-3670 • Fax 206-431-3665
PERMIT COORD COPY
PLAN REVIEW/ROUTING SLIP
PERMIT NUMBER: M16-0062
DATE: 04/22/16
PROJECT NAME: PRICECO
SITE ADDRESS: 1002 ANDOVER PARK E
X Original Plan Submittal Revision #
Response to Correction Letter #
DEPARTMENTS:
Building Division is
Public Works ❑
PRELIMINARY REVIEW:
Not Applicable ❑
(no approval/review required)
REVIEWER'S INITIALS:
APPROVALS OR CORRECTIONS:
Approved ❑
Corrections Required ❑
(corrections entered in Revieu,$)
REVIEWER'S INITIALS:
At& Awc
Fire Prevention
before Permit Issued
Revision # after Permit Issued
Structural ❑
Planning Division ❑
Permit Coordinator of
DATE: 04/26/16
Structural Review Required ❑
DATE:
DUE DATE: 05/24/16
Approved with Conditions
Denied ❑
(ie: Zoning Issues)
DATE:
Permit Center Use Only
CORRECTION LETTER MAILED:
Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials:
12/18@013
BUDGETHVACUS LLC
Home L,spanol Contact
Safety & Health
Washington State Deparpnent of
Labor & Industries
BUDGETHVACUS LLC
Page 1 of 2
Search L&I ; r
A -"L Index Flelp My L&I
Claims & Insurance Workplace Rights Trades & Licensing
Owner or tradesperson
420 37TH ST NW #H
Wesco Insurance Co
AUBURN, WA 98001
Principals
206-473-9914
DIDLAKE, JAMES
KING County
RICHARD, PARTNER/MEMBER
Effective date
Doing business as
01/26/2014
BUDGETHVACUS LLC
Expiration date
WA UBI No. Business type
603 169 929 Limited Liability Company
License
Verify the contractor's active registration / license / certification (depending on trade) and any past violations.
CContracor
...............................onstruction................................t..... . Active.
Meets current requirements.
License specialties
Heating/Vent/Air-Conditioning and Refrig
(HVAC/R)
License no.
BUDGEL'882B7
Effective — expiration
01127/2012— 01128/2018
Bond
................
$1,000,000.00
Wesco Insurance Co
$6,000.00
Bond account no.
46WBO41039
Effective date
Received by L&I
Effective date
01/28/2014
01/26/2014
Expiration date
Until Canceled
Bond history
Insurance
Security National Insurance
$1,000,000.00
Policy no.
NA110010601
Received by L&I
Effective date
01/26/2016
01/26/2016
Expiration date